Transcript
Product is discontinued Measurement sensors
KM1
SERIES
Amplifier Built In Analog Sensors Linear analog output is incorporated in the same package as KA1 Photoelectric Sensors
* Original
Sensor
FEATURES Accurate measurement regardless of colors, materials, and different target shapes Analog sensor can measure white or black target at the same distance.
Various outputs are provided for wide range of applications • Alarm output: PNP or NPN output type is selectable for the polarity of output circuit. • Analog output: Voltage or current output type is selectable. Excellent linearity characteristics with aspherical lens The lens used in KM1 analog sensor is a high-precision, aspherical type. This assures accurate detection without aspherical and coma abberation, and also reduces temperature drift. Resistive for soild lens surface Analog sensor measures the distance by the incidence angle, not the received light intensity. Even if the lens surface is soiled by dust or any powdery material, there is a little variation of distance range.
Immersion protected construction (equivalent to IEC IP67) High speed measurement of 5 ms Ambient temperature range: –25 to +60°C –13 to +140°F Indicators STAB. (stability) indicator LED (green)
ALARM indicator LED (red)
MEASURABLE RANGE Measurable range (m ft.) 0.2 .656
0.7 2.297
Voltage output type Current output type
PRODUCT TYPE Measurable range
0.2 to 0.7 m .656 to 2.297 ft.
80
Rated operating voltage
24 V DC
Light source
Infrared LED
Control output
Resolution (2σ)
Voltage output 1 to 10 V (Max. 2 mA)
0.05 V
Current output 4 to 20 mA (Max. 5 V)
0.1 mA
03/2003
Alarm output
Part number
NPN PNP NPN PNP
AKM17114 AKM17115 AKM17164 AKM17165
KM1 SPECIFICATIONS 1) Ratings Output type Rated operating voltage Rated power consumption
Voltage output
Current output 24 V DC
50 mA or less
70 mA or less
2) Performance Product type Measurement method Maximum range Measurable range Standard detection object Operating voltage range Output voltage Output current Analog Resolution (2σ) output Response time (10 to 90%) Temperature drift Initial breakdown voltage Initial insulation resistance Vibration resistance Shock resistance Alarm output Protective construction Usable ambient light level Ambient temperature Ambient humidity Storage temperature Indicator Light source
AKM17114
AKM17115 AKM17164 Optical triangulation range measurement method 70 cm 2.297 ft. 20 to 70 cm .656 to 2.297 ft. 2020 cm 7.8747.874 inch white drawing paper
AKM17165
19.2 to 28.8 V DC ripple (P-P) included Max. 10% 1 to 10 V (Max. 2 mA), output impedance 50 Ω — — 4 to 20 mA (Max. 5 V), load impedance Max. 250 Ω 0.05 V 0.1 mA 5 ms Max. (±0.3% of F.S.)/°C 500 V AC between input/output and external housing for 1 min. Min. 20 MΩ between input/output and external housing (at 500 V DC) 10 to 55 Hz (1 cycle/min), double amplitude 1.5 mm .059 inch (2 hours each in the vertical, horizontal and lateral directions) 980 m/s2 {approx. 100 G} (3 times each in the vertical, horizontal and lateral directions) NPN type (50 mA, 30 V DC)/PNP type (50 mA), Open collector 1 line Residual voltage: NPN type: Max. 1.2 V; PNP type: Max. 2 V (switching at 50 mA) Plastic case, immersion proof type (equivalent IEC IP67) Incandescent lamp: 3,000 lux; Sunlight: 10,000 lux –25 to +60°C –13 to +140°F (non-icing condition) 35 to 85% R.H. (non-condensing condition) –20 to +70°C –4 to +158°F Green LED (STABILITY), Red LED (ALARM) Infrared LED
Notes: 1. Unless otherwise specified, the measurement conditions comprise rated operating voltage, 20°C 68°F ambient temperature, standard detectable target and 200 lux or less illuminance on receiver surface. 2. F.S.: Measurable range Resolution: The standard deviation σ in the variation of the values measured at the detection distance should be doubled.
3) Output circuit diagram Voltage output type (Alarm output: NPN)
Current output type (Alarm output: NPN)
Voltage output type (Alarm output: PNP)
Current output type (Alarm output:PNP)
Blue line (0 V) and shield line are connected on the main circuit. For power supply, blue line should be used with brown line (+24 V). For analog output shield line should be used with black line (analog output).
03/2003
81
KM1 DATA 1. Projector beam diameter characteristics
2. Distance characteristics
The beam diameter is regarded as the diameter which attenuates at 1/e2 (Here e]2.72)
Target size: 2020 cm 7.7847.784 inch 1) Voltage output type
2) Current output type 12
100 dia. 3.937
0.8 2.625
56 dia. 2.205
0.4 1.312
Black drawing paper
16 12 8
44 dia. 1.732
0.2 .656
10
0 20 .656
30 .984
60 40 50 1.312 1.641 1.969 Distance (cm ft.)
90
0 20 .656
35 30 25 Black drawing paper
White drawing paper
40 50 60 1.312 1.641 1.969 Distance (cm ft.)
60 40 50 1.312 1.641 1.969 Distance (cm ft.)
70 2.297
10,000
80
1,000
70 60 50
Black drawing paper
40
30 .984
30 .984
Target: White drawing paper Size: 2020 cm 7.7847.784 inch
20 20 .656
5. Temperature characteristics
100
10
Operating level
White drawing paper
30
70 2.297
Relative signal level
40 Resolution: 2σ (µA)
Resolution: 2σ (mV)
100
45
5 0 20 .656
4
70 2.297
2) Current output type
50
10
6
4. Received signal level and distance characteristics
Target size: 2020 cm 7.7847.784 inch 1) Voltage output type
15
Black drawing paper
2
3. Resolution characteristics
20
8
4
80 80 120 40 0 40 120 4.724 3.150 1.575 1.575 3.150 4.724 – Beam diameter (mm inch) +
White drawing paper
Rated distance range
0.6 1.969
White drawing paper
20
Output current (mA)
1 3.281
Output voltage (V)
Operating distance (m ft.)
24
30 .984
40 50 60 1.312 1.641 1.969 Distance (cm ft.)
1 0
70 2.297
6. Detectable target characteristics
10 20 30 40 50 60 70 80 90 100 .328 .984 1.641 2.297 2.953 .656 1.312 1.969 2.625 3.281 Distance (cm ft.)
7. Material characteristics Target size: 2020 cm 7.7847.784 inch
50 cm 1.641 ft. setting 30 cm .984 ft. setting
12/23.6
10 8
10/20
6
Analog output (V/mA)
70 cm 2.297 ft. setting
Error (% of F.S.)
12
4 2 0 –2 –4 –6
20 cm .656 ft. setting
8/16.4
50 cm 1.641 ft. setting
White drawing paper Black drawing paper
40 cm 1.312 ft. setting
Plywood
70 cm 2.297 ft. setting 60 cm 1.969 ft. setting
Set for 70 cm 2.297 ft. Set for 40 cm 1.312 ft. Set for 20 cm .656 ft.
6/12.9
–8
Black rubber without gloss
30 cm .984 ft. setting 4/9.3 2/5.8
Standard target White drawing paper 20×20 cm 7.784×7.784 inch
Black rubber with gloss White acrylic board
20 cm .656 ft. setting
–10 –12 –30 –20 –10 0 10 20 30 40 50 60 –22 –4 14 32 50 68 86 104 122 140 Temperature (°C °F)
0/2.2 1 .155
10 100 1000 1.550 15.500 155.000 Target size (cm2 inch2)
0/2.2
2/5.8
4/9.3
8/16.4 12/23.6 6/12.9 10/20 Analog output (V/mA)
mm inch
DIMENSIONS KM1 Analog sensor
Sensor with blacket STABILITY indicator LED (green)
4 .157
2.5 .098
(21.5) (.846) 11.5 .453
19.6 .772
20 7.2 .787 .283
ALARM indicator LED (red) 45 1.772 12.5 .492 5 .197
8.8 25 .346 10 .984 (10) .394 (.394) 45 5 .197 1.772
24 .945 68 60±0.2 19 .748 2.677 2.362±.008
82
60 77.9 2.362 3.067
5 .2 .8D 28 ia D . ia .
2-4.2Dia. 2-.165Dia.
. in m 00 4 20 8.7 7
(4) (.157)
4.2 .165
20 .787
03/2003
23 .906
11.2 .441 1.5 .059
KM1 CAUTIONS
1. Operating Environment 1) The sensor should be used in an ambient temperature range of –25 to +60°C –13 to +140°F and ambient humidity range of 35 to 85% or the location where water does not condense by sudden temperature change. 2) Use an operating voltage in the range of 19.2 to 28.8 V DC (less than 10% of ripple P-P). 3) The light intensity on the receiver surface should be less than 3,000 lux for an incandescent light and less than 10,000 lux for sunlight and especially affected by lower illumination of inverter fluorescent lamp. 4) Use a surge absorber as the internal circuit may be damaged if external surge voltages exceed 500 V±(1.250) µs (single polarity full-wave voltage). 5) Avoid use in locations with high concentrations of steam, dust corrosive gases, where sunlight is directly shined, directly on top of equipment with heat generation and influenced by generated heat. 6) The sensor is immersion protected type, but this does not mean that it can be used in water or where there is direct impingement of rain for detecting targets. 2. Wiring 1) Check all wiring before applying power since incorrect wiring may damage internal circuit. 2) Ground the frame ground (FG) terminal and ground (G) terminal to avoid the influence from high frequency noise when using a commercially available switching regulator. If a ground is not connected, switching noise from the power supply may result in faulty. 3) Insulated transformer should be used when using a transformer for the power source. Sensor and transformer may be damaged if autotransformer is used. 4) Care should be taken to allow the voltage drop (NPN type max. 1.2 V or PNP type max. 2 V) from the operating voltage in the case that a relay coil is connected to the alarm output. 5) If cable is extended, the equivalent cable whose length is 10 m 32.81 ft. or less should be used for the analog output part. Wire 0.3 mm2 .0005 inch2 or larger should be used for wiring up to a length of 50 m 164.05 ft. for the other terminals.
6) A shielded wire should be used for analog output line and separated from high voltage circuit and power circuit. If unavoidable, analog output should be wired separately and shielded by the conductor such as earthed electric wire. 3. Noise 1) Sensor should be installed as far as possible from high voltage line (equipment), power line (equipment), the equipment with transmitter of wireless communication, the equipment which generates the large switching surge. 2) In the case that large noise is conducted through power supply, a noise filter or noise cut transformer shall be used, since the analog output is affected by such a noise. 4. Warming-up time For the use in which high precision required, be sure to secure the warming-up time of 30 min or more after power is turned ON. 5. Detector 1) Keep the detector surface clean as excessive dust or dirt on the detector surface will decrease the margin of the detection distance. 2) The front surface of the lens and case are made of polycarbonate resin. Although it withstands water, weak acids and alkalines, aliphatic hydrocarbons, oils and fats, it is not resistant to ketones, esters, halogenated hydrocarbons and aromatic hydrocarbons. 6. Target 1) Mounting direction of the sensor with respect to the movement direction of the target must be in the following two direction.
8. Alarm output This output is energized when the luminous volume received from an object exceeds or become less than the specified value (50 mA, 30 V DC open collector). 9. Other cautions 1) When using optional mounting bracket, tighten the mounting screws with a maximum torque of 0.8 N·m {8.2 kgf·cm 7.09 lbf·in}. If the optional mounting bracket is not used, mount the sensor on a flat surface. 2) Be sure to mount the sensor with the detecting face of sensor and object being on horizontal, as shown in the following illustration.
3) If the sensors are mounted adjacently, they shall be so separated as not to have mutual interference.
100 mm 3.937 inch
100 mm 3.937 inch
100 mm 3.937 inch
100 mm 3.937 inch
2) Correct detection may not be possible for shiny, non-reflection, and transparent object, or liquid. 7. Analog output When alarm output is “ON’’, correct analog output van not be obtained. Analog output is less than 1 V (4 mA) at a distance range less than 20 cm .656 ft. between sensor and target, more Analog output characteristic 10 V 20 mA Output
These products are not safety sensors and are not designed or intended to be used to protect life and prevent bodily injury or property damage.
1V 4 mA 20 cm .656 ft.
Distance
70 cm 2.297 ft.
than 10 V (20 mA) at a distance range more than 70 cm 2.297 ft.
03/2003
83