Datasheet www.sbc-support.com KOL Timer, electronic ■ ■ ■ ■ ■ ■ ■ Multi function or mono function 4 (KOL251) or 6 time ranges (KOL 1, KOL 3) 17.5 mm width for DIN rail 110…240 VAC 24 …48 VDC and 24…240 VAC 1 make contact (KOL 1) or 2 make contacts (KOL251) 1 changeover contact (KOL 3) From left to right: KOL360, KOL311 KOL 1/ 2 • • Delayed release • Fleeting-on delay timer • Flasher relay KOL 3 • • • • • • • • 1 make contact • • • • • • • • • • • • • • • • • • • • • • • 2 make contacts with a joint connection • KOL251H7MKVPN00 KOL160H7MRR1N00 KOL142H7MRR1N00 KOL121H7MRR1N00 KOL112H7MRR1N00 KOL111H7MRR1N00 1 changeover contact Order no. • • KOL360H7MRVPN00 • KOL342H7MRVPN00 • 24…48 VDC and 24…240 VAC 110…240 VAC Number of contacts • KOL321H7MRVPN00 0.15 s…10 min 0.05 s…10 h Operating voltage Settings Rough time setting e.g., 1 m = 1 minute Fine setting time Divides the value set in the rough setting by a factor of 10 Example: rough setting 1 m = 1 minute 1 unit = 6 s. If 24 s are necessary, factor 4 must be set here • • • • • • • • Star-delta timer Time ranges • KOL312H7MRVPN00 Delayed operation KOL311H7MRVPN00 Functions Function settings (only with KOL160/360) Here you can set the relay function, e.g.,11 - delayed operation Technical data Multi time ranges Setting accuracy Repeat accuracy Reset time Operating voltage Power consumption Duty cycle Pulse control Outputs Switching capacity Insulation characteristics EMC/immunity to interference EMC/emissions Approvals Ambient temperature Connections Mounting KOL251 0.15…3 s, 0.5…10 s, 3 s…60 s, 0.5…10 min KOL 1 und KOL 3 0.05…1 s, 0.5…10 s, 0.05…1 min, 0.5…10 min, 0.05…1 h, 0.5…10 h Time range can be freely selected on the front using a screwdriver ±5 % of the time range final value (tmax) 1% of the time range final value (tmax) 100 ms KOL 1 KOL251, KOL 3 110…240 VAC, 50/60 Hz (A1/A2) 24…48 VDC and 24…240 VAC, 50/60 Hz AC: –15 %/10 % DC: ±20% AC: –15 %/10 % 0.5 W at 24 VDC or 5 VA at 250 VAC 100 % Operating voltage range, current 1 mA, duration of the control pulse >50 ms 1 make contact (KOL 1), 2 make contacts (KOL251) or 1 changer (KOL 3) U = 250 VAC, Ith = 5 A, P = 1250 VA 1.5 A/ 250 VAC (AC15) or 1 A/24 VDC (DC13) in accordance with IEC60947-5-1 2 kV/ 50 Hz test voltage in accordance with VDE 0435 and 4 kV 1.2 /50 µs surge voltage in accordance with IEC60947-5-1 between all inputs and outputs Surge capacity in accordance with IEC61000-4-5, 4 kV (2 kV to A3-A2) Burst in accordance with IEC61000-4-4, 4 kV ESD in accordance with IEC61000-4-2, 8 kV Electromagnetic fields in accordance with EN 55 022, class B UL, C-UL (KOL 1) or UL, C-UL, Germanischer Lloyd (KOL251, KOL 3) KOL 1 KOL 2 and KOL 3 –20 °C to +50 °C –20 °C to +60 °C Screw terminals for 1 × 0.5 mm² or 2 × 2.5 mm², for Pozidrive no. 1 (max. 1Nm) or screwdriver. Finger protection in accordance with VDE0106 Snap-on mounting on 35 mm rail according to EN60715TH35 or screw mounting by adapter (accessories) Accessories ■ Adapter Order no. CJ260 for screw mounting 4 104 5077 3 Dimension diagrams Timer Screw adaptor (accessories CJ260, order no. 4 104 5077 3) 80 45 43 17.5 2| www.saia-pcd.com 66 70 Datenblatt 31/005: Timer, electronic KOL Time diagram and connection diagram KOL 1/ 2 Delayed operation (11) L/+ = LED orange: Output in operating mode = LED green: operating voltage available A1/A2 or A3/A2 U 15 A2 18 15/18 t Output A1 N/– Delayed release (12) = LED green: operating voltage available A1/A2 or A3/A2 U = LED orange: Output in operating mode S L/+ A1 B1 S 15 A2 18 A1 15 A2 18 A1 15 A2 18 B1/B2 or A3/A1 Output t 15/18 N/– Fleeting-on delay timer (21) L/+ = LED orange: Output in operating mode = LED green: operating voltage available A1/A2 or A3/A2 U 15/18 t Output N/– Flasher relay (42) = LED orange: Output in operating mode = LED green: operating voltage available A1/A2 or A3/A2 U Output t t t t t L/+ 15/18 N/- Star-delta (51) A1/A2 U = LED green: operating voltage available Datenblatt 31/005: Timer, electronic KOL Y t L/+ A1 17 A2 18 17/18 17/28 tu = 50...65 ms N/- 28 www.saia-pcd.com |3 Time diagram and connection diagram KOL 3 Delayed operation (11) L/+ = LED orange: Output in operating mode = LED green: operating voltage available A1/A2 or A3/A2 U 15 t Output A1 15 A2 18 16 18 16 N/– Delayed release (12) = LED green: operating voltage available A1/A2 or A3/A2 U = LED orange: Output in operating mode S L/+ A1 B1 S 15 A2 18 16 A1 15 A2 18 16 B1/B2 or A3/A1 Output 15 18 16 t N/– Fleeting-on delay timer (21) L/+ = LED orange: Output in operating mode = LED green: operating voltage available A1/A2 or A3/A2 U 15 t Output 18 16 N/– Flasher relay (42) = LED orange: Output in operating mode = LED green: operating voltage available A1/A2 or A3/A2 U Output t t t t t L/+ Bahnhofstrasse 18 | 3280 Murten, Schwitzerland T +41 26 672 72 72 | F +41 26 672 74 99 www.saia-pcd.com [email protected] | www.sbc-support.com P+P31/005  EN04  01. 2014  Subjects to change without notice. 15 A2 18 16 15 18 16 N/- Saia-Burgess Controls AG A1