Transcript
Timer
KOP.F
Electronic
KOP.F Characteristics
large rotary dial DIN dimensions ■ multifunction ■ multi time range ■ multi voltage ■ ■
Mounting
■ ■
flush mounting plug-in on 11 pin socket
Dimensions (mm) 45 x 45 x 95 Functions* 211, 212, 217, 221, 223, 247 by external wiring Time ranges 12 time ranges, selected 0.01s...10 h Outputs 1 relay with two contacts as change-over, 250 VAC, 5 A Supply voltage 24...230 VDC/VAC, 50/60 Hz
Preferred Range Ordering Reference
Characteristics
KOP260F0MWVAN00
Panel cut out 48 x 48 mm Multi time range 0.01 s...10 h Supply voltage 24...230 V AC/DC Multi functions: Delayed, Fleeting, Impulse converter, Flasher relay
* 11: delayed operation; 12: delayed release; 16: delayed operation and release; 21: fleeting-on delay timer; 22: fleeting-off delay timer; 23: impulse converter; 24: impulse generator; 42: flasher relay; 28: watchdog; 31/70: asymmetrical timer; 51: star-delta timer; 19: power off delayed release
20 | 21
www.saia-burgess.com
saia-burgess Control Devices
KOP.F
Technical data Multi time ranges
Setting accuracy Repeat accuracy Reset time Supply voltage Power consumption Duty cycle Pulse control Outputs Switching capacity Insulation characteristics EMC/Interference immunity EMC/Emissions Protection class Approvals Ambient temperature Mounting
saia-burgess Control Devices
0.01…0.5 s 0.01…0.5 min 0.01…0.5 h 0.02… .1 s 0.02… .1 min 0.02… .1 h 0.1… .5 s 0.1… .5 min 0.1… .5 h 0.2….10 s 0.2….10 min 0.2….10 h time range, unit of time and function are all selected from front panel with screwdriver ±3% of the time range final value (tmax.) ±1% of the time range final value (tmax.) 100 ms with pulse control 300 ms with supply control 24…230 VDC/VAC, ±15%, 50/60 Hz 3 W at VDC, 3.5 VA at VAC 100% supply voltage range, duration of the control pulse >50 ms 1 relay with two contacts as change-over, green LED remains lit during timing U = 250 VAC, Ith = 5 A, P = 1250 VA 2.5 A/250 VAC (AC 14), 5 A/24 VDC 2 kVAC/50 Hz test voltage according to VDE 0435 and 4 kV 1.2/50 ms surge voltage according to EN 60 947-5-1 between all inputs and outputs surge capacity according to IEC 1000-4-5, level 3; Burst according to IEC 1000-4-4, level 3; ESD according to IEC 1000-4-2, level 3 electromagnetic fields according to EN 55 022, class B front IP 40 UL, C-UL –10°C to +55°C flush mounting with plastic spring clip or surface mounting with plug-in socket (accessory) for mounting with 2 screws M3 or snap-on mounting on DIN rail 35 mm, any mounting position
www.saia-burgess.com
20 | 21
KOP.F
Technical data Circuit diagrams
A Delayed operation with pulse control (211) ❏ U Outputs 1⁄2 green LED yellow LED
A Delayed operation with pulse control (217) ❏ U S1) Outputs 1⁄2 green LED yellow LED
B Fleeting-on delay timer (221) ❏ U S2) Outputs 1⁄2 green LED yellow LED
B Impulse converter (223) ❏ U S Outputs 1⁄2 green LED yellow LED
C Flasher relay starting with pause and reset (247) ❏ U S3) Outputs 1⁄2 green LED yellow LED
D Delayed release (212) ❏ U S Outputs 1⁄2 green LED yellow LED 1) 2)
22 | 23
The falling edge of S starts the sequence of t; the rising edge of S leads to a reset of t. Function 221 requires a jumper between terminals 2 and 7.
www.saia-burgess.com
saia-burgess Control Devices
KOP.F
Technical data Dimensions
Panel cut out: 45 x 45 mm
Ordering Reference Type KOP Function 260
Multi function with 2 contacts
Housing F0
Flush or plug-in type mounting (11 poles)
Time ranges MW Supply voltage BA
BK CA CW R1 VA
0.01 s...10 h, multi time range 12 VAC/DC 24 VAC/DC 48 VAC/DC 110 VAC/DC 110...240 VAC 24...230 VAC/DC
NOO Accessories CJ 211 11-pin socket (47 x 47 x 20 mm) for flush mounting, connections with screw terminals
CJ 250 11-pin socket (68 x 68 x 24 mm) for mounting with screws or snap-on mounting on DIN rail 35 mm connections with screw terminals
saia-burgess Control Devices
www.saia-burgess.com
22 | 23