Transcript
PACKAGED GASL" / ELECTRIC PACKAGED SERIES
LG L SERIES® ROOFTOP UNITS − 60HZ
ENGINEERING DATA
Variable or Constant Air Volume 13 to 30 Tons Bulletin No. 210318 August 2004 Supersedes July 2004
Insulated Panels in all Conditioned Areas
Copper Tube Coil with Enhanced Fins
Humiditrol® Hot Gas Reheat Option Available (Not Shown) (Not available for all models)
MERV 7 Filters Furnished (Optional MERV 11 Available)
Thermally Protected Outdoor Coil Fan Motors with PVC Coated Fan Guard Independent Fan Motor Mount (Separate from fan guard)
Hinged Access Panels with Quarter Turn latches
Heavy Gauge Galvanized Steel Panels with Two−layer Enamel Paint Finish
Intelligent Unit Controller Solid−State Microprocessor Provides Flexible Control of all Unit Functions and Diagnostics
High and Low Pressure Switches
Thermal Expansion Valves with Filter Drier
R−410A Refrigerant Available (15, 20, 21 and 30 Ton High Efficiency Models Only)
Belt Drive Blowers Circuit Breaker, Disconnect and GFI Service Outlets Available
Full Perimeter Base Rail with Rigging Holes and Fork Lift Slots
Aluminized Steel Heat Exchanger (Optional Stainless Steel Available)
Fully Insulated Base
Refrigerant Service Valves Available
Power/Gas Entry Through Base or Side of Unit
Combustion Air Inducer
Aluminized Steel Inshot Burners
Copeland Scroll Compressors with Crankcase Heater
Dual Stage Gas Valve with Manual Shut−Off
ASHRAE 90.1 COMPLIANT
NOTE − Due to Lennox’ ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2004 Lennox Industries Inc.
TABLE OF CONTENTS Accessory Air Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 39−41 Blower Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 36−38 Cooling Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 22−32 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 54−65 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 42−45 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2−6 Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 47 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 66−74 High Altitude Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 35 Humiditrol® Condenser Reheat Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 8−9 Humiditrol® Condenser Reheat Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 33−35 Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 46 Model Number Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 7−11 Optional Disconnect Switch Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 42 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 12−21 Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 45 System Controller / Unit Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 48−53 Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 54 & 60
MODEL NUMBER IDENTIFICATION
L G C 240 S 2 B S 1 Y Voltage Y = 208/230V-3 phase-60hz G = 460V-3 phase-60hz J = 575V-3 phase-60hz
Brand/Family L = L Series Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Nominal Cooling Capacity − Tons 156 = 13 Tons 180= 15 Tons 210 = 17.5 Tons 240 = 20 Tons 248 = 21 Tons 300 = 25 Tons 360 = 30 Tons Cooling Efficiency S = Standard Efficiency H = High Efficiency
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 2
Minor Design Sequence 1 = 1st Revision 2 = 2nd Revision 3 = 3rd Revision Heating Type L = Low Gas Heat, 1 Stage S = Standard Gas Heat, 2 Stage M = Medium Gas Heat, 2 Stage H = High Gas Heat, 2 Stage Blower Type B = Constant Air Volume (CAV) − Belt Drive V = Variable Air Volume (VAV) − Belt Drive Refrigerant Type 2 = R−22 4 = R−410A
FEATURES AND BENEFITS APPROVALS ETL and CSA listed. Heating efficiency ratings verified by CSA. Components bonded for grounding to meet safety standards for servicing required by UL, CSA and National and Canadian Electrical Codes. 156 thru 248 models are certified in accordance with the ULE certification program, which is based on ARI Standard 340/360-2000. 300 and 360 models are tested at conditions included in ARI Standard 340/360−2000. ISO 9001 Registered Manufacturing Quality System. ENERGY STAR® certified units are designed to use less energy, help save money on utility bills, and help protect the environment.
WARRANTY Limited ten years aluminized heat exchanger, limited fifteen years optional stainless steel heat exchanger. Limited five years on compressors. Limited three years on Integrated Modular Control. Limited one year all other covered components.
COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. Two efficiency levels provide flexibility. System can operate from 0°F to 125°F without any additional controls. Compressors Resiliently mounted on rubber grommets for quiet operation. Copeland Scroll compressors on all models for high performance, reliability and quiet operation. Compressor Crankcase Heaters Protects against refrigerant migration that can occur during low ambient operation. Thermal Expansion Valves Assures optimal performance throughout the application range. Removable element head. Filter/Driers High capacity filter/driers protect the system from dirt and moisture. High Pressure Switches Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation. Automatic reset Low Pressure Switches Protects the compressor from low pressure conditions such as low refrigerant charge, or low/no air flow. Automatic reset
Freezestats Protects the evaporator coil from damaging ice build−up due to conditions such as low/no air flow, or low/no refrigerant charge. Coil Construction Copper tube construction, enhanced rippled−edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Evaporator Coil Cross row circuiting with rifled copper tubing optimizes both sensible and latent cooling capacity. Low fin per inch count minimizes air pressure drop. Constant air volume (CAV) models have face−split evaporator coils. Variable air volume (VAV) models have row−split evaporator coils designed to keep condensate water off of an inactive part of the coil so the condensate will not re−enter the air stream. Condenser Coil Angled, slab design helps protect coil from possible contact or hail damage. Condensate Drain Pan Drain connection extends outside unit. Painted, galvanized pan with positive slope. Stainless steel drain pan available as a factory installed option. Outdoor Coil Fan Motors Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount. Outdoor Coil Fan PVC coated fan guard furnished. Refrigerant Choice LGC180H, LGA240H, LGA248H, and LGA360H models can be ordered with R−22 or R−410A refrigerant systems. REQUIRED SELECTIONS Cooling Capacity − Specify the nominal cooling capacity of the unit Cooling Efficiency − Specify either standard or high efficiency. Refrigerant Choice (LGC180H, LGA240H, LGA248H, and LGA360H Models Only) Specify R−22 or R−410A refrigerant. OPTIONS Factory Installed Service Valves − Fully serviceable brass valves installed in discharge & liquid lines. Not for use with Humiditrol equipped units. 4 Heat/4 Cool Control Board − Add−on board that enables the unit to operate four stages of cooling and four stages of gas heat when controlled by a 4−stage thermostat or DDC control system. Stainless Steel Condensate Drain Pan Factory or Field Installed Condensate Drain Trap − Field installed only, may be factory enclosed to ship with unit. Available in copper or PVC.
HEATING SYSTEM Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic single or dual stage gas valve with manual shut-off. Heat Exchanger Tubular construction, aluminized steel, life cycle tested. Stainless Steel Heat Exchanger is required if mixed air temperature is less than 45°F. Fan & Limit Controls Factory installed with fixed temperature setting. Heat limit controls protect against overheating. Safety Switches Flame roll−out switches, flame sensors and combustion air inducer proving switches protect system operation. All safety switches are monitored by the IMC unit controller and diagnostic errors are reported and recorded. REQUIRED SELECTIONS Gas Input − Order one: 169,000 Btuh Low Heat Gas Input (LGC156, LGC180 and LGC210 models only). 169,000 / 260,000 Btuh low/high fire − Standard Heat Gas Input. 234,000 / 360,000 Btuh low/high fire − Medium Gas Heat Input. 312,000 / 480,000 Btuh low/high fire − High Gas Heat Input (Not available for LGC156). OPTIONS Factory Installed Stainless Steel Heat Exchanger − Required if mixed air temperature is below 45°F. 4 Heat/4 Cool Control Board − Add−on board that enables the unit to operate four stages of cooling and four stages of gas heat when controlled by a 4−stage thermostat or DDC control system. Factory or Field Installed Fresh Air Tempering − Used in applications with high outside air requirements. The IMC energizes the first stage heat as needed to maintain a minimum supply air temperature for comfort, regardless of the thermostat demand. When ordered as a factory option, the sensor ships with the unit but must be field installed. Field Installed Combustion Air Intake Extensions − Recommended for use with existing flue extension kits in areas where high snow drifts can block intake air. LPG/Propane Kits − Conversion kit to field change over units from Natural Gas to LPG/Propane. Vertical Vent Extension Kit − Exhausts flue gases vertically above unit.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 3
FEATURES AND BENEFITS BLOWER A wide selection of supply air blower options are available to meet a variety of air flow requirements. Motor Overload protected, equipped with ball bearings. Belt drive motors are offered in several different sizes to maximize air performance. Motor Efficiency Specify standard or high. Supply Air Blower Forward curved blades, blower wheel is statically and dynamically balanced. Belt drive motors with adjustable pulley for speed change on CAV units. Blower assembly slides out of unit for servicing. Grease fittings furnished. REQUIRED SELECTIONS Supply Air Blower Specify Constant Air Volume (CAV) or Variable Air Volume (VAV). VAV units require supply duct−mounted, pressure control sensor. Order Standard or High Efficiency Blower motor (See Blower Data Table for specifications). Order one drive kit, see Drive Kit Specifications Table. OPTIONS Factory Installed Supply VFD Blower Bypass Control − Allows variable air volume (VAV) unit to operate as a constant air volume (CAV) unit in case of variable frequency drive (VFD) failure. Field Installed Duct Limit − Field installed limit switch will shut down unit when duct pressure is greater than setpoint. Manual reset. Requires installation kit. Duct Mounted Pressure Control Sensor − VAV units require field installed supply duct−mounted, pressure control sensor.
CABINET Construction Heavy−gauge steel panels and full perimeter heavy−gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have fork slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Air−Flow Choice Units are available in down−flow (vertical) or horizontal return air flow configuration. Horizontal air flow requires Horizontal Roof Curb. Horizontal Return Air Panel Kit is also required if converting a down−flow configured unit to horizontal air flow.
Power and Gas Entry Electrical and gas lines can be brought through the unit base or through horizontal access knock−outs. Exterior Panels Constructed of heavy−gauge, galvanized steel with a two−layer enamel paint finish. Insulation All panels adjacent to conditioned air are fully insulated with non−hygroscopic fiberglass insulation. Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. Access Panels Hinged access panels are provided for 2 compressor/controls/heating areas, blower access and air filter/economizer access. All panels have seals and quarter−turn latching handles to provide a tight air and water seal. REQUIRED SELECTIONS Air Flow Configuration − Specify horizontal or down−flow. OPTIONS Factory Installed Corrosion Protection − Phenolic epoxy coating, applied to condenser coils (with painted base section) and evaporator coils (with painted base and painted blower housings), factory applied to either section or both sections. Field Installed Coil Guards − Painted, galvanized steel wire guards to protect outdoor coil. Not used with Hail Guards. Grille Guards − Protects the space between outdoor coils and main cabinet. Hail Guards − Constructed of heavy gauge steel, painted to match cabinet, helps protect outdoor coils from hail damage. Not used with Coil Guards. Horizontal Return Air Panel Kit − Required for horizontal applications with Horizontal Roof Curb, contains panel with return air opening for field replacement of existing unit panel and panel to cover bottom return air opening in unit, see dimension drawings.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 4
AIR FILTERS Disposable 2 inch (51 mm) pleated MERV 7 filters (Minimum Efficiency Reporting Value based on ASHRAE 52.2). OPTIONS Factory or Field Installed MERV 11 Filters − Disposable 2 inch pleated MERV 11 filters (Minimum Efficiency Reporting Value based on ASHRAE 52.2).
FEATURES AND BENEFITS CONTROLS Intelligent Unit Controller
The Integrated Modular Control (IMC) is a solid−state microprocessor−based control board that provides flexible control of all unit functions. All control voltage is provided via a 24V (secondary) transformer with built−in circuit breaker protection. Built-in functions include: Blower On/Off Delay − Adjustable time delay between blower on and off. Blower Air Delivery Options − Three air delivery options; single zone CAV, bypass zoning with bypass dampers, and modulating VAV with VFD. optional GP1 board required for VAV or bypass zoning. Built-in Control Parameter Defaults − No programming required for standard CAV models. Compressor Time−Off Delay − Adjustable time delay between compressor shutoff and start up. DDC Compatible − Various third party DDC controllers can be factory or field installed. Refer to the Unit Controllers section for details. Dirty Filter Switch Input − When a Dirty Filter Switch is installed, the IMC will signal when the indoor blower static pressure increases, indicating a dirty filter condition. Switch is optional and can be factory or field installed. Discharge Air Control − The IMC will cycle up to 4 stages of heating or cooling to maintain the discharge air setpoints for heating or cooling. The factory installed discharge air sensor must be relocated to the supply duct for proper measurements. Display/Sensor Readout − Displays control parameters, diagnostic codes, and sensor readings. The IMC unit controller displays temperature readings from return air, supply air, and outdoor air sensors that are furnished as standard on all L Series units. IMC will also display readings from optional sensors such as zone sensors, CO2 sensors or relative humidity sensors. Economizer Control Choice − the economizer is controlled by an add−on board to the IMC. The economizer control board has four choices (DIP switch selectable) for controlling the economizer. 1 − Sensible Control − Uses the outdoor air and return air sensors that are furnished with the unit. The IMC compares the two temperatures and enables the economizer when the outdoor air is cooler than return air.
2 − Differential Sensible Control − Uses the outdoor air and return air sensors that are furnished with the unit. The IMC compares the outdoor air and return air and, using setpoints, enables the economizer when the outdoor air is cooler than return air. 3 − Global Enthalpy Control − the IMC communicates with a DDC system that uses one global sensor (enthalpy or sensible), to determine whether outside air is suitable for free cooling on all units connected to the control system. Sensor must be field provided. 4 − Outdoor Enthalpy Control − Senses outdoor air enthalpy and enables economizer if the enthalpy is less than the setpoint of the board. Can be ordered factory or field installed. 5 − Differential Enthalpy Control − Two solid-state enthalpy sensors allow the control board to select between outdoor air or return air, whichever has lower enthalpy. Can be ordered factory or field installed. Fresh Air Tempering − The IMC energizes the first stage heat as needed to maintain a minimum supply air temperature for comfort, regardless of the thermostat demand. For factory option, sensor ships with unit but must be field installed in the supply air duct. Extensive Unit Diagnostics − The IMC monitors all sensors and functions related to unit operation to provide critical information. The IMC will display detailed diagnostic information with over 80 diagnostic codes to pinpoint any problems and reduce troubleshooting time. All diagnostic codes are listed inside control access panel for easy reference. Exhaust Fan Control Modes − Fans controlled by fresh air damper position (non−VFD power exhaust) or or solid−state building static pressure sensor (VFD power exhaust). Permanent Diagnostic Code Storage − Maintains diagnostic codes through a power failure. Field Changeable Control Parameters − Over 200 different control parameters allow customization of the unit operation by changing delays, cooling stages, deadbands, and setpoints. Indoor Air Quality Input − The IMC is Demand Control Ventilation ready from the factory (optional field installed CO2 sensor required). Two modes of operation are available: setpoint and proportional. 1 − Setpoint − Opens the economizer dampers to full position when CO2 setpoint level is reached. 2 − Proportional − Opens the dampers at the first set point and gradually increases it as the CO2 level increases until the second setpoint is reached. Low Ambient Controls − Allows unit cooling operation down to 0°F.
Gas Valve Time Delay Between First and Second Stage − Allows gradual increase of input rate. Minimum Compressor Run Time − Ensures proper oil return to the compressor. Network Capable − The IMC can be daisy chained to other L Series units or L Connection ® Network controllers using twisted pair wire. Night Setback Mode − Adjusts setpoints, closes outdoor air dampers and operates the blower on demand, may be customized for special requirements. Return Air Temperature Limit Control − Allows the user to override the demands based upon the return air temperature during either heating or cooling operation. Helps protect against abnormal operating conditions in the event of a room sensor or thermostat failure. Safety Switch Input − Normally−closed digital input allows the IMC to respond to a external safety switch trip (phase protector, low voltage, etc.) shutting down unit operation. Service Relay Output − Digital output can indicate a critical error has occurred to an external control device. Can also be configured to energize based on relative humidity, indoor air quality, outdoor air temperature or unit operation. Smoke Alarm Mode − Control board has four choices for responding to a smoke alarm. 1 − Unit Off − unit will turn off. 2 − Positive Pressure − blower is energized, exhaust fan is de−energized, and the outdoor air dampers are opened. 3 − Negative Pressure − blower is energized, exhaust fan is energized, and the outdoor air dampers are closed. 4 − Purge − blower is energized, exhaust fan is energized, and the outdoor air dampers are opened. Staging − 2 heat/2 cool. Capable of up to 4 heat/4 cool with zone sensor or with optional FS1 board and 4 heat/4 cool thermostat or third party DDC control system. Strike Three" Protection − Ends cooling or heating operation when any of the following occurs three times (adjustable) within a thermostat cycle: low pressure trip, high pressure trip, heat limit trip, or freeze−stat trip. Gas Reheat − Control parameter option that allows simultaneous heating and cooling operation on CAV gas units for controlling humidity for process air applications such as supermarkets. Field installed relative humidity sensor or dehumidistat can be used.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 5
FEATURES AND BENEFITS CONTROLS − CONTINUED On−Demand Dehumidification − Monitors and controls condenser hot gas bypass operation with Humiditrol option. Prioritizes heat and cool demand with dehumidification demand. Reheat demand can be enabled by digital input or a field installed relative humidity sensor can be used. CAV models only. Thermostat Bounce Delay − Protects compressor from short cycling when mechanical thermostat is used. Warm-up Mode Delay − Adjustable time that the economizer dampers are kept in the closed position during morning warm−up. On−Board User Interface − Push−button, DIP switches used with three−digit display readout for field adjustment of control parameters. LED indicators for L Connection Network (transmit and receive) and for each thermostat input. PC Interface − PC with optional Unit Controller software may be used to field or remotely adjust parameters, read alarms, or display unit status. VAV Control − Supports variable frequency drive (VFD) or bypass variable air volume applications with add−on control board. Zone Sensor Operation − Controls zone temperature with up to 4 stages of heating or cooling with optional zone sensor (FS1 Board not required). OPTIONS Factory Installed
GP1 Board − Multi−purpose board that provides the inputs/outputs necessary for VAV or bypass zoning units. A second GP1 board may be added to provide additional configurable general purpose input/outputs. The GP1 has 2 digital inputs, 1 digital output, 4 analog inputs and 2 analog outputs. 4 Heat / 4 Cool Control Board (FS1) − Provides additional 24VAC thermostat inputs for 4 heat/4 cool thermostats and DDC controls. Factory installed.
Factory or Field Installed Blower Proving Switch − Monitors blower operation, shuts down unit if blower fails. Factory installed. Commercial Control − Unit controllers and system controllers. Field installed. See Pages 48−52. Dirty Filter Switch − Senses static pressure increase indicating dirty filter condition. Smoke Detector − Photoelectric type, installed in supply air section or return air section or both sections Indoor Air Quality (CO2) Sensor − Monitors CO2 levels, reports to IMC board which adjusts economizer dampers as needed. Field Installed Humidity Sensor Kit, Remote Mounted − Humidity sensor required with factory installed Humiditrol Option. Thermostat Control Systems − See page 53.
ELECTRICAL REQUIRED SELECTIONS Voltage Choice − Specify 208/23V, 460V or 575V 3−phase−60hz when ordering base unit. OPTIONS Factory Installed Circuit Breakers up to 250 Amp − HACR circuit breaker without power distribution lugs. Accessible from outside of unit, spring−loaded weatherproof cover furnished. Main power to the unit is field connected to the circuit breaker which allows all power to be shutoff for service. Circuit breaker is sized to the unit maximum overcurrent protection (MOCP) size. Field Installed Disconnect Switch up to 250 Amp − Accessible from outside of unit, spring loaded weatherproof cover furnished. Main power to the unit is field connected to the disconnect which allows all power to be shut off for service. See Optional Disconnect Switch Requirements table, Page 42 for field installed disconnect switches. GFI Service Outlets (2) − 115v ground fault circuit interrupter (GFCI) type, field wired or unit powered.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 6
SERVICEABILITY Designed to streamline general maintenance and decrease troubleshooting time. Diagnostics IMC diagnostic codes pinpoint problems, minimizing troubleshooting time. Marked & Color−Coded Wiring All electrical wiring is color−coded and marked to identify which components it is connecting. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Tool−less, Hinged Access Panels Large access panels are hinged and have quarter−turn, latching handles for quick and easy access to maintenance areas. Filter access panels are hinged for easy access to the filters. Blower Access Blower assembly slides out of the unit for easy access. Coil Cleaning Slab condenser coils allow easier cleaning. Standard Components A large number of common maintenance parts are standard throughout the entire range of sizes (3−30 tons), reducing the need to carry a lot of different parts to the job or in inventory. Compressor Compartment Compressors are located near the perimeter of the unit for easier access. Compressors are isolated from the condenser air flow allowing system operation checks to be done without changing the air flow across the outdoor coils. Thermal Expansion Valves Thermal expansion valves are located near the perimeter of the unit for easier access. Removable element head allows change out of element and bulb without removing the TXV. Service Valves (optional) Optional factory installed liquid and discharge service valves allow refrigerant to be isolated to the high side for service work on the low side of the refrigeration system.
OPTIONS ECONOMIZER/OUTDOOR AIR/EXHAUST OPTIONS Factory or Field Installed Economizer − Parallel gear driven action recirculated air and outdoor air dampers, plug-in connections to unit, nylon bearings, neoprene seals, 24 volt fully modulating spring return motor, adjustable minimum damper position, damper assembly slides in unit, outdoor air hood must be ordered separately, optional down-flow barometric relief dampers available, choice of economizer controls, the IMC add−on board for economizer control is included with the economizer. Enthalpy Control Kit − Differential − Two solid-state enthalpy sensors that allow the economizer control board to select between outdoor air or return air, whichever has lower enthalpy. Enthalpy Control Kit − Outdoor − Outdoor air enthalpy sensor that allows the economizer control board to open the dampers if the outdoor enthalpy is less than the setpoint of the board. Down−Flow Barometric Relief Dampers − Allows relief of excess air, aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle, bird screen furnished, see Field Installed section (below) for damper hood Outdoor Air Damper Section − Linked mechanical dampers, 0 to 25% (fixed) outdoor air adjustable, installs in unit, outdoor air hood must be ordered separately. Automatic model features fully modulating spring return damper motor with plug−in connection. Manual model features a slide damper. Minimum mixed air temperature in heating mode 30°F. Maximum mixed air temperature in cooling mode: 90°F. Outdoor Air Hood − Required with LAREMD Economizer, LAOAD and LAOADM Outdoor Air Damper Sections, cleanable aluminum mesh fresh air filters furnished.
Power Exhaust Fans (PEF)
CEILING DIFFUSERS
Standard Static Power Exhaust − LAPEF18/24 models have two, 1/3 hp motors with 20 in., five blade propeller−type fans with a total power input of 750 Watts and a total air volume of 8630 cfm at 0 in. w.g.. LAPEF30/36 models have three, 1/3 hp motors with 20 in., five blade propeller−type fans with a total power input of 1125 Watts and a total air volume of 12,800 cfm at 0 in. w.g. Motor is inherently protected and enclosed for maximum protection from weather, dust and corrosion. Installs internal to unit for down-flow applications only with economizer option, provides exhaust air pressure relief, interlocked to run when return air dampers are closed and supply air blower is operating, fan runs when outdoor air dampers are 50% open (adjustable), motor is overload protected, steel cabinet and hood painted to match unit, requires optional Down-flow Economizer Barometric Relief Dampers. See Standard Static Power Exhaust Blower Tables. Control options include: Power Exhaust Control − Damper Position Economizer control board controls the power exhaust fans based on the position of the outside air dampers. In two fan applications the fans are staged.
Field Installed Ceiling Diffusers − Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed (prevents recirculation), adapts to T-bar ceiling grids or plaster ceilings. Transitions (Supply and Return) − Used with diffusers, installs in roof curb, galvanized steel construction, flanges furnished for duct connection to diffusers, fully insulated.
ROOF CURBS Field Installed Nailer strip furnished, mates to unit, shipped knocked down. Down−Flow − US National Roofing Contractors Approved, available in 14 inch and 24 inch heights Horizontal − Converts unit from down-flow to horizontal (side) air flow, return air is on unit, supply air is on curb, see dimension drawings. Curbs for rooftop applications meet National Roofing Code requirements. Requires Horizontal Return Air Panel. Available in 26 inch, 30 inch, 37 inch and 41 inch heights. Optional Insulation Kit is available to help prevent sweating. Roof Curb, Cliplock 1000 Full Perimeter − Available in 14 inch, 18 inch and 24 inch heights.
Field Installed Down−Flow Barometric Relief Damper Hood − Field installed only. Horizontal Barometric Relief Dampers − Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle, field installed in return air duct, bird screen furnished.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 7
OPTIONS HUMIDITROL® HOT GAS BYPASS REHEAT OPTION 156H & 180H (3 Compressors) 210H, 240H & 300S (4 Compressors) R−22 CAV MODELS ONLY Factory installed option designed to control humidity. Provides dehumidification on demand using ASHRAE 90.1 recommended method for reheat with comfort conditioning humidity control. In addition to a thermostat/room sensor used for conventional operation, a humidity sensor is required and must be located in the occupied space. Humidity sensor provides input to the Integrated Modular Control (IMC) which is used to control activation of the dehumidification operation. Reheat controls are located in the compressor control section of the unit for easy access. Benefits Improves indoor air quality. Helps prevents damage due to high humidity levels. Improves comfort levels by reducing space humidity levels.
Operation No Dehumidification Demand The unit will operate conventionally whenever there is a demand for cooling or heating and no dehumidification demand. Free cooling is only permitted when there is no demand for dehumidification. Dehumidification Demand Only The IMC is factory set at 60% relative humidity setpoint and can be adjusted at the IMC or with optional Unit Controller Software. For Network Control Panel (NCP) applications, the humidity setpoint can be adjusted at the NCP. The unit will operate in the dehumidification mode
until the relative humidity of the conditioned space is 3% below the setpoint. Reheat operation will initiate on a dehumidification demand and does not require a cooling demand. The reheat coil is sized to offset most of the first stage sensible cooling effect during reheat only operation. This reduction in sensible cooling capacity extends compressor run time to control humidity when cooling loads are light. Solenoid valves divert hot gas from compressor 1 and compressor 2 to the reheat coil. The cooled and dehumidified air from the evaporator is then reheated as it passes through the reheat coil. The de−superheated and partially condensed refrigerant continues to the outdoor condenser coil where condensing is completed. The unit will continue to operate in this mode until the dehumidification demand is satisfied. A heating demand will terminate reheat operation. Dehumidification and Cooling Demand for 156H/180H three compressor models (Thermostat Application) If both a dehumidification and a first stage cooling demand occur, the system will operate compressor 1 and compressor 2 in reheat and compressor 3 will operate in cooling. A demand for second stage cooling will terminate reheat operation until second stage cooling demand is satisfied. Dehumidification and Cooling Demand for 210H/240H/300S four compressor models (Thermostat Application)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 8
If both a dehumidification and a first stage cooling demand occur, the system will operate compressor 1 and compressor 2 in reheat and compressor 3 and compressor 4 will operate in cooling. A demand for second stage cooling will terminate reheat operation until second stage cooling demand is satisfied. Dehumidification and Cooling Demand for 156H/180H three compressor models (Room Sensor Application) If both a dehumidification and a first stage cooling demand occur, the system will operate compressor 1 and compressor 2 in reheat and compressor 3 will operate in cooling. A demand for second stage cooling will terminate reheat and compressor 3 operation and operate compressor 1 and compressor 2 in cooling until second stage cooling demand is satisfied. A demand for third stage cooling will operate compressor 1, compressor 2 and compressor 3 in cooling. Dehumidification and Cooling Demand for 210H/240H/300S four compressor models (Room Sensor Application) If both a dehumidification demand and a first stage cooling demand occur, the system will operate compressor 1 and compressor 2 in reheat and compressor 3 will operate in cooling. If a demand for second stage cooling is initiated, compressor 1 and compressor 2 will operate in reheat and compressor 3 and compressor 4 will operate in cooling. A demand for third stage cooling will terminate reheat and compressor 4 operation and operate compressor 1, compressor 2 and compressor 3 in cooling until third stage cooling demand is satisfied. A demand for fourth stage cooling will operate compressor 1, compressor 2, compressor 3 and compressor 4 in cooling.
OPTIONS HUMIDITROL® HOT GAS BYPASS REHEAT OPTION (CONTINUED) REFRIGERANT SCHEMATIC (156H, 180H MODELS ONLY) NOTE: Refrigerant circuits one and two operates when there is a first-stage thermostat demand. MIXED INDOOR/OUTDOOR AIR
3 CONDENSER COIL
2 1 2
2 1 1
2
1
2
3
3
3
OUTDOOR AIR 1
REFRIGERANT CIRCUIT 1
2
REFRIGERANT CIRCUIT 2
3
REFRIGERANT CIRCUIT 3 REHEAT VALVE
S
CHECK VALVE THERMAL EXPANSION VALVE
REFRIGERANT SCHEMATIC (210H, 240H and 300S MODELS ONLY) NOTE: Refrigerant circuits one and two operates when there is a first-stage thermostat demand. MIXED INDOOR/OUTDOOR AIR
4 3
CONDENSER COIL
2 1 2
2 1
1
2
4 3
2
4 3
1 OUTDOOR AIR 1
REFRIGERANT CIRCUIT 1
2
REFRIGERANT CIRCUIT 2
3
REFRIGERANT CIRCUIT 3
4
REFRIGERANT CIRCUIT 4
S
REHEAT VALVE CHECK VALVE THERMAL EXPANSION VALVE
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 9
OPTIONS The model and catalog numbers that appear here are for ordering field installed accessories only. Item Cabinet A Accessories i
Ceiling Diffusers
Controls
Fact Fact. Field
Barometric Relief
Outdoor Air Dampers
Power Exhaust Fans
15 ton 17.5 ton 20 ton 180
210
240
25 ton
21 ton
25 ton
30 ton
300S
248H
300H
360
%
88K52
88K53
Grille Guards
%
78K78
86K30
Hail Guards
%
88K25
88K26
Horizontal Return Air Panel Kit
%
38K47
38K48
Step−Down Net Weight
%
RTD11−185 392 lbs. (178 kg)
RTD11−275 403 lbs. (183 kg)
LARTD30/36 437 lbs. (198 kg)
Flush Net Weight
%
FD11−185 289 lbs. (135 kg)
FD11−275 363 lbs. (165 kg)
LAFD30/36 414 lbs. (188 kg)
Transitions (Supply and Return) Net Weight
%
LASRT18 80 lbs. (36 kg)
LASRT21/24 75 lbs. (34 kg)
LASRT30/36 85 lbs. (39 kg)
Blower Proving Switch
S
%
LTABPSK
Commercial Controls
S
%
See Pages 48 − 53
Dirty Filter Switch
S
%
LTADFSK
Duct Limit
%
79M80
Duct Limit Installation Kit
%
79M81
%
78M19
Smoke Detector − Supply
S
%
LTASASDK10/36
Smoke Detector − Return
S
%
LTARASDK03/36
PVC Condensate Drain Trap
S
%
LTACDKP03/36
Copper Condensate Drain Trap
S
%
LTACDKC03/36
Service Valves
S
Factory installed option (Not for use on Humiditrol equipped units)
S
Factory installed option
Corrosion Protection Economizer/ Outdoor Air Exhaust/ Power Exhaust Options
156
Coil Guards
Duct Mounted Pressure Control Sensor
Cooling A Accessories i
13 ton
Economizer Net Weight
S
%
Outdoor Air Hood Net Weight Number and Size of Filters
S
%
Economizer Enthalpy Control − Differential
S
%
LTADEK03/36
Economizer Enthalpy Control − Outdoor
S
%
LTASEK03/36
Economizer Control − Global (sensor must be field provided)
S
%
See Intelligent Unit Controller Features, Page 5−6
Economizer Control − Sensible
S
%
See Intelligent Unit Controller Features, Page 5−6
Down−Flow Barometric Relief Dampers Net Weight
S
%
LAGED18/24 30 lbs. (14 kg)
LAGED30/36 45 lbs. (20 kg)
Hood for Down−Flow LAGED
%
LAGEH18/30S
LAGEH30H/36
Horizontal Barometric Relief Dampers Net Weight
%
LAGEDH18/24 20 lbs. (9 kg)
LAGEDH30/36 20 lbs. (9 kg)
LAREMD18/24 86 lbs. (39 kg)
LAREMD30/36 119 lbs. (54 kg)
LAOAH18/24 65 lbs. (29 kg) (3) 16 x25 x 1 in. (406 x 635 x 25 mm)
LAOAH30/36 76 lbs. (34 kg) (5) 16 x25 x 1 in. (406 x 635 x 25 mm)
Damper Section − Automatic Net Weight
S
%
LAOADM18/24 52 lbs. (24 kg)
LAOADM30/36 72 lbs. (33 kg)
Damper Section − Manual Net Weight
S
%
LAOAD18/24 49 lbs. (22 kg)
LAOAD30/36 68 lbs. (31 kg)
Outdoor Air Hood Net Weight Number and Size of Filters
S
%
LAOAH18/24 65 lbs. (29 kg) (3) 16 x25 x 1 in. (406 x 635 x 25 mm)
LAOAH30/36 76 lbs. (34 kg) (5) 16 x25 x 1 in. (406 x 635 x 25 mm)
Standard Static Net Weight
S
%
LAPEF18/24 62 lbs. (28 kg)
LAPEF30/36 99 lbs. (45 kg)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 10
OPTIONS The model and catalog numbers that appear here are for ordering field installed accessories only. Item
Fact Fact. Field Disconnect Switch
S
HACR Circuit Breaker
S
GFI Service Outlets − Field Wired
S
GFI Service Outlets − Unit Powered
S
MERV 11 High Efficiency
S
Electrical A Accessories i
Filters
Gas Heating Accessories
Combustion Air Intake Extensions Fresh Air Tempering
S
LPG/Propane Kit
Stainless Steel Heat Exchanger
Indoor Air Q lit (CO2) Quality Sensors
Roof C b Curbs
15 ton 17.5 ton 20 ton 180
210
25 ton
21 ton
25 ton
30 ton
300S
248H
300H
360
240
See Optional Disconnect Switch Requirements Page 42 Factory installed option
%
31M78 Factory installed option
%
AFK−11 (24 x 24 x 2 order six per unit)
AFK−11 (20 x 20 x 2 order twelve per unit)
%
LTACAIK10/15 2 kits required
%
45L78
%
LTALPGK−169 − For Low Heat (2 kits required) LTALPGK−260 − For Standard Heat (2 kits required) LTALPGK−360 − For Medium (2 kits required) LTALPGK−480 − For High Heat (2 kits required) Factory installed option
% S
LTAWEK10/15 2 kits required Factory installed option
Not Available
17M50
Not Available
Humidity Sensor Kit, Remote Mounted
%
CO2 Sensor Duct Mounting Kit
%
LTIAQSDMK03/36
Sensor − white case CO2 display
%
LTAIAQSWDK03/36
Sensor − white case no display
%
LTAIAQSWN03/36
Sensor − black case CO2 display
%
LTAIAQSND03/36
Sensor − duct mount, black, no display
%
LTAIAQSDMBN03/36
Aspiration Box for duct mounting
%
LTIAQABD03/36
Handheld CO2 Monitor
%
LTAIAQSHM03/36
Down−Flow − 14 in. (356 mm) height − Net Wt.
%
LARMF18/36−14 − 160 lbs. (73 kg)
24 in. (610 m) height − Net Weight
%
LARMF18/36−24 − 220 lbs. (100 kg)
Cliplock 1000 Curbs − 14 in. (356 mm) Height
%
LARMF18/30S−14
LARMF30/36S−14
18 in. (457 mm) Height
%
LARMF18/30S−18
LARMF30/36S−18
24 in. (610 mm) Height
%
LARMF18/30S−24
LARMF30/36S−24
Horizontal − for slab applications 26 in. (660 mm) height − Net Weight
%
LARMFH18/24−26 − 420 lbs. (191 kg)
Not Available
30 in. (762 mm) height − Net Weight
%
Horizontal − for rooftop applications 37 in. (940 mm) height − Net Weight
%
41 in. (1041 mm) height − Net Weight
%
Horizontal Insulation kit − 26 in. (660 mm) curbs
1
156
S
Vertical Vent Extension Kit Humiditrol ® Hot Gas Reheat Option 156H, 180H, 210H, 240H and 300S
%
13 ton
%
for 30 in. (762 mm) curbs
%
for 37 in. (940 mm) curbs
%
for 41 in. (1041 mm) curbs
%
Not Available
1
LARMFH30/36−30 − 445 lbs. (202 kg)
LARMFH18/24−37 − 580 lbs. (263 kg)
Not Available 73K32 Not Available 73K34 Not Available
1
Not Available
LARMFH30/36−41 − 725 lbs. (329 kg) Not Available 73K33 Not Available 73K35
LARMFH30/36 or LARMFH18/24 horizontal roof curbs may be used for the 300S models, however, the smaller LARMF18/24 curbs will increase static pressure.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 11
SPECIFICATIONS − STANDARD EFFICIENCY COOLING (CAV) General Data
Nominal Tonnage Model No. Efficiency Type Blower Type Cooling g Gross Cooling Capacity − Btuh (kW) Performance P f 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant g Charge g Circuit 1 Furnished (R-22) (R 22) Circuit 2 Circuit 3 Circuit 4 Gas Heating Heat Input Type Performance Input − Btuh (KW) First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure − Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Condenser Motor horsepower (W) F Fans Motor rpm Total Motor watts Diameter − in. (mm) No. of blades Total Air volume − cfm (L/s) Evaporator p Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) No. of rows Fins per inch (m) Drain connection − number and size Expansion device type 3 Indoor Nominal motor output Blower and Drive Selection Maximum usable motor output (US Only) Motor − Drive kit
15 Ton
15 Ton LGC180S2B (R−22) Standard Constant Air Volume (CAV) 186,000 (54.5) 180,000 (52.7) 6000 (2830) 18.0 10.0 10.6 9 lbs. 0 oz. (4.08 kg) 9 lbs. 0 oz. (4.08 kg) 9 lbs. 0 oz. (4.08 kg) −−− Low Standard Medium High 1 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) −−− 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 135,000 (39.6) −−− −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (3) 56.5 (5.25) 3/8 (9.5) 1 20 (787) (4) 1/3 (249) 1075 1370 (4) 24 (610) 3 15,850 (7480) 22.3 (2.07) 3/8 (9.5) 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 3 hp (2.2 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 8.63 hp (6.4 kW) 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 865 rpm kit #2 − 685 − 865 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 1045 rpm kit #4 − 945 − 1185 rpm
Blowerwheelnominaldiameterxwidth Type of filter No. and size − in. (mm) Electrical characteristics Filters
7.5 hp kit# 5 − 945 − 1185 rpm kit# 6 − 1045 − 1285 rpm kit# 7 − 850 − 1045 rpm (2) 15 x 15 in. (381 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase
NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 12
SPECIFICATIONS − STANDARD EFFICIENCY COOLING (CAV) General Data
Nominal Tonnage Model No. Efficiency Type Blower Type Gross Cooling Capacity − Btuh (kW) Cooling g P f Performance 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Circuit 1 Refrigerant g Charge g Furnished (R-22) (R 22) Circuit 2 Circuit 3 Circuit 4 Gas Heating Heat Input Type Performance Input − Btuh (KW)
First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure − Natural LPG/Propane Compressor Type (no.) Net face area − sq. ft. (m2) total Condenser C il Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Motor horsepower (W) Condenser F Fans Motor rpm Total Motor watts Diameter − in. (mm) No. of blades Total Air volume − cfm (L/s) Net face area − sq. ft. (m2) total Evaporator p C il Coils Tube diameter − in. (mm) No. of rows Fins per inch (m) Drain connection − number and size Expansion device type 3 Indoor Nominal motor output Blower and Drive Maximum usable motor output Selection (US Only) Motor − Drive kit
Blowerwheelnominaldiameterxwidth Type of filter No. and size − in. (mm) Electrical characteristics Filters
17.5 Ton
17.5 Ton LGC210S2B (R−22) Standard Constant Air Volume (CAV) 212,000 (62.1) 204,000 (59.8) 6800 (3210) 20.4 10.0 10.5 7 lbs. 0 oz. (3.18 kg) 7 lbs. 0 oz. (3.18 kg) 7 lbs. 0 oz. (3.18 kg) 7 lbs. 0 oz. (3.18 kg) Low Standard Medium High 1 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) −−− 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 135,000 (39.6) −−− −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (4) 56.5 (5.25) 3/8 (9.5) 1 20 (787) (4) 1/3 (249) 1075 1370 (4) 24 (610) 3 15,850 (7480) 22.3 (2.07) 3/8 (9.5) 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 3 hp (2.2 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 8.63 hp (6.4 kW) 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 1045 rpm kit #2 − 685 − 1045 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 865 rpm kit #4 − 945 − 1185 rpm 7.5 hp kit# 5 − 945 − 1185 rpm kit# 6 − 1045 − 1285 rpm kit# 7 − 850 − 1045 rpm (2) 15 x 15 in. (381 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase
NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 13
SPECIFICATIONS − STANDARD EFFICIENCY COOLING (CAV)
20 and 25 Ton
General Data G General l Data
Nominal Tonnage 20 Ton 25 Ton Model No. LGC240S2B (R−22) LGC300S2B (R−22) Efficiency Type Standard Standard Blower Type Type Constant Air Volume (CAV) Constant Air Volume (CAV) Cooling g Gross Cooling Capacity − Btuh (kW) 243,000 (71.2) 302,000 (88.4) P f Performance 1 232,000 (67.9) 2 286,000 (83.7) Net Cooling Capacity − Btuh (kW) Total Unit Power (kW) 24.4 30.1 ARI Rated Air Flow − cfm (L/s) 8000 (3775) 9000 (4250) 1 9.5 2 9.5 EER (Btuh/Watt) 3 Integrated Part Load Value (Btuh/Watt) 9.8 9.7 Refrigerant g Charge g Circuit 1 11 lbs. 0 oz. (4.99 kg) 11 lbs. 4 oz. (5.10 kg) Furnished (R-22) (R 22) Circuit 2 11 lbs. 0 oz. (4.99 kg) 11 lbs. 4 oz. (5.10 kg) Circuit 3 11 lbs. 0 oz. (4.99 kg) 11 lbs. 4 oz. (5.10 kg) Circuit 4 11 lbs. 0 oz. (4.99 kg) 11 lbs. 4 oz. (5.10 kg) Refrigerant g Charge g Circuit 1 Not Available 12 lbs. 4 oz. (5.56 kg) Furnished (R-22) (R 22) Circuit 2 Not Available 12 lbs. 4 oz. (5.56 kg) with Humiditrol Option Circuit 3 Not Available 11 lbs. 4 oz. (5.10 kg) Circuit 4 Not Available 11 lbs. 4 oz. (5.10 kg) Gas Heating Heat Input Type Standard Medium High Standard Medium High Performance 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage Input − Btuh (kW) First Stage 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) Second Stage 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) Output − Btuh (kW) Second Stage 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) CSA Thermal Efficiency 80.0% 80.0% Gas Supply Connections 1 in. 1 in. Recommended Gas Supply Pressure Natural 7 in. w.g. (1.7 kPa) 7 in. w.g. (1.7 kPa) LPG/Propane 11 in. w.g. (2.7 kPa) 11 in. w.g. (2.7 kPa) Compressor Type (no.) Scroll (4) Scroll (4) Condenser Net face area − sq. ft. (m2) total 56.5 (5.25) 56.5 (5.25) C il Coils Tube diameter − in. (mm) 3/8 (9.5) 3/8 (9.5) Number of rows 2 2 Fins per inch (m) 20 (787) 20 (787) Condenser Motor horsepower (W) (4) 1/3 (249) (4) 1/2 (373) F Fans 1075 Motor rpm 1075 Total Motor watts 1395 1800 Diameter − in. (mm) (4) 24 (610) (4) 24 (610) No. of blades 3 3 Total Air volume − cfm (L/s) 15,450 (7290) 16,000 (7550) Evaporator p Net face area − sq. ft. (m2) total 22.3 (2.07) 22.3 (2.07) C il Coils Tube diameter − in. (mm) 3/8 (9.5) 3/8 (9.5) No. of rows 3 4 Fins per inch (m) 14 (551) 14 (551) Drain connection − number and size (1) 1 in. NPT coupling (1) 1 in. NPT coupling Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head 4 Indoor Nominal motor output 5 hp (3.7 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 7.5 hp (5.6 kW) Blower and 10 hp (7.5 kW) 10 hp (7.5 kW) Drive Maximum usable motor output 5.75 hp (4.3 kW) 5.75 hp (4.3 kW) Selection (US Only) 8.63 hp (6.4 kW) 8.63 hp (6.4 kW) 11.5 hp (8.6 kW) 11.5 hp (8.6 kW) Motor − Drive kit 5 hp 5 hp kit #2 − 685 − 865 rpm kit #2 − 685 − 865 rpm kit #3 − 850 − 1045 rpm kit #3 − 850 − 1045 rpm kit #4 945 − 1185 rpm kit #4 − 945−1185 rpm 7.5 hp 7.5 hp kit #5 − 945 − 1185 rpm kit #5 − 945 − 1185 rpm kit #6 − 1045 − 1285 rpm kit#6 − 1045−1285 rpm kit #7 − 850 − 1045 rpm kit #7 − 850 − 1045 rpm 10 hp 10 hp kit #6 − 1045−1285 rpm kit #6 − 1045 − 1285 rpm kit #8 − 1135−1365 rpm kit #8 − 1135−1365 rpm Blowerwheelnominaldiameterxwidth (2) 15 x 15 in. (381 x 381 mm) (2) 15 x 15 in. (381 x 381 mm) Filters Type of filter Disposable, pleated MERV 7 (standard) or MERV 11 (optional) No. and size − in. (mm) (6) 24 x 24 x 2 (610 x 610 x 51) Electrical characteristics 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Tested at conditions included in with ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 3 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 4 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 14
13 Ton
SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) General D t Data
Nominal Tonnage Model No. Efficiency Type Blower Type Type
Gross Cooling Capacity − Btuh (kW) 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Circuit 1 Refrigerant Charge F Furnished i h d (R (R-22) 22) Circuit 2 Circuit 3 Circuit 1 Refrigerant Charge F Furnished i h d (R (R-22) 22) Circuit 2 with Humiditrol Option Circuit 3 Gas Heating Heat Input Type Performance
13 Ton LGC156H2B (R−22) High Constant Air Volume (CAV)
Cooling P f Performance
Input − Btuh (kW)
First Stage Second Stage
Output − Btuh (kW)
First Stage Second Stage
CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser C il Coils Condenser F Fans
Evaporator C il Coils
3
Indoor Blower and Drive Selection
Net face area − sq. ft. (m2) total Tube diameter − in. (mm) − No. of rows Fins per inch (m) Motor horsepower (W) Motor rpm Total Motor watts Diameter − in. (mm) − No. of blades Total Air volume − cfm (L/s) Net face area − sq. ft. (m2) total Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condensate Drain − number and size Expansion device type Nominal motor output Maximum usable motor output (US Only) Motor − Drive kit number
Blowerwheelnom. dia.xwidth−in.(mm) Type of filter No. and size − in. (mm) Electrical characteristics Filters
Low 1 Stage
160,000 (46.8) 156,000 (45.7) 5100 (2405) 12.8 12.2 13.6 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 13 lbs. 8 oz. (6.12 kg) 13 lbs. 8 oz. (6.12 kg) 11 lbs. 0 oz. (4.99 kg) Standard 2 Stage
Medium 2 Stage
169,000 (49.5)
169,000 (49.5)
234,000 (68.6)
−−−
260,000 (76.2)
360,000 (105.5)
135,000 (39.6)
−−−
−−−
−−−
208,000 (60.9)
288,000 (84.4)
80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (3) 56.5 (5.25) 3/8 (9.5) − 2 20 (787) (4) 1/3 (249) 1075 1395 (4) 24 (610) − 3 15,450 (7290) 22.3 (2.07) 3/8 (9.5) − 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 2 hp (1.5 kW) 3 hp (2.2 kW) 5 hp (3.7 kW) 2.3 hp (1.7 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 2 hp kit #A − 535 − 725 rpm 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 865 rpm kit #2 − 685 − 865 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 1045 rpm kit #4 − 945 − 1185 rpm (2) 15 x 15 (381 x 381) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase
NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 15
SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) General D t Data
Cooling Performance
Nominal Tonnage Model No. Efficiency Type Blower Type Gross Cooling Capacity − Btuh (kW) 1
Net Cooling Capacity − Btuh (kW)
ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge Circuit 1 F Furnished i h d ((R (R-22) 22)) Circuit 2 Circuit 3 Circuit 4 Refrigerant Charge Circuit 1 F Furnished i h d ((R (R-410A) 410A)) Circuit 2 Circuit 3 Refrigerant Charge Circuit 1 F i h d ((R 22)) Furnished (R-22) Circuit 2 with Humiditrol Option Circuit 3 Circuit 4 Gas Heating Heat Input Type Performance Input − Btuh (kW) First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condenser Motor horsepower (W) F Fans Motor rpm Total Motor watts Diameter − in. (mm) − No. of blades Total Air volume − cfm (L/s) Evaporator Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condensate Drain − number and size Expansion device type 3 Indoor Nominal motor output Blower and Drive Selection Maximum usable motor output (US Only) Motor − Drive kit number
Blowerwheelnom. dia.xwidth−in.(mm) Type of filter No. and size − in. (mm) Electrical characteristics Filters
15 Ton
15 Ton LGC180H2B (R−22) LGC180H4B (R−410A) High Constant Air Volume (CAV) 188,000 (55.1) (R−22) 190,000 (55.7) (R−410A) 182,000 (53.3) (R−22 184,000 (53.9) (R−410A) 5700 (2690) 15.4 (R−22) 16.1 (R−410A) 11.8 (R−22) 11.4 (R−410A) 13.3 (R−22) 12.8 (R−410A) 11 lbs. 8 oz. (5.22 kg) 11 lbs. 8 oz. (5.22 kg) 11 lbs. 8 oz. (5.22 kg) −−− 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) 14 lbs. 0 oz. (6.35 kg) 14 lbs. 0 oz. (6.35 kg) 11 lbs. 8 oz. (5.22 kg) −−− Low Standard Medium High 1 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) −−− 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 135,000 (39.6) −−− −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (3) 56.5 (5.25) 3/8 (9.5) − 2 20 (787) (4) 1/3 (249) 1075 1395 (4) 24 (610) − 3 15,450 (7290) 22.3 (2.07) 3/8 (9.5) − 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 3 hp (2.2 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 8.63 hp (6.4 kW) 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 865 rpm kit #2 − 685 − 865 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 1045 rpm kit #4 − 945 − 1185 rpm 7.5 hp kit# 5 − 945 − 1185 rpm kit# 6 − 1045 − 1285 rpm kit# 7 − 850 − 1045 rpm (2) 15 x 15 (381 x 381) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase
NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 16
SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) General Data
Nominal Tonnage Model No. Efficiency Type Blower Type Cooling Gross Cooling Capacity − Btuh (kW) 1 Net Cooling Capacity − Btuh (kW) Performance P f ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge Circuit 1 F Furnished i h d ((R (R-22) 22)) Circuit 2 Circuit 3 Circuit 4 Refrigerant Charge Circuit 1 F i h d ((R 410A)) Furnished (R-410A) Circuit 2 Circuit 3 Refrigerant Charge Circuit 1 F Furnished i h d ((R (R-22) 22)) Circuit 2 with Humiditrol Option Circuit 3 Circuit 4 Gas Heating Heat Input Type Performance Input − Btuh (kW) First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condenser Motor horsepower (W) F Fans Motor rpm Total Motor watts Diameter − in. (mm) − No. of blades Total Air volume − cfm (L/s) Evaporator Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condensate Drain − number and size Expansion device type 3 Indoor Nominal motor output Blower and Drive Selection Maximum usable motor output (US Only) Motor − Drive kit number
Blowerwheelnom. dia.xwidth−in.(mm) Type of filter No. and size − in. (mm) Electrical characteristics Filters
17.5 Ton
17.5 Ton LGC210H2B (R−22) High Constant Air Volume (CAV) 218,000 (63.9) 210,000 (61.5) 6600 (3115) 18.3 11.5 12.3 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) −−− −−− −−− 13 lbs. 0 oz. (5.90 kg) 13 lbs. 0 oz. (5.90 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) Low Standard Medium High 1 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) −−− 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 135,000 (39.6) −−− −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (4) 56.5 (5.25) 3/8 (9.5) − 2 20 (787) (4) 1/3 (249) 1075 1395 (4) 24 (610) − 3 15,450 (7290) 22.3 (2.07) 3/8 (9.5) − 4 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 3 hp (2.2 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 8.63 hp (6.4 kW) 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 1045 rpm kit #2 − 685 − 1045 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 865 rpm kit #4 − 945 − 1185 rpm 7.5 hp kit# 5 − 945 − 1185 rpm kit# 6 − 1045 − 1285 rpm kit# 7 − 850 − 1045 rpm (2) 15 x 15 (381 x 381) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase
NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 17
SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) General D t Data
Cooling Performance
Nominal Tonnage (kW) Model No. Efficiency Type Blower Type Gross Cooling Capacity − Btuh (kW) 1 Net
Gas Heating Performance
Cooling Capacity − Btuh (kW)
ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge Circuit 1 F i h d ((R-22) Furnished (R 22)) Circuit 2 Circuit 3 Circuit 4 Refrigerant Charge Circuit 1 F i h d ((R-410A) Furnished (R 410A)) Circuit 2 Circuit 3 Circuit 4 Refrigerant Charge Circuit 1 F i h d ((R-22) Furnished (R 22)) Circuit 2 with Humiditrol Option Circuit 3 Circuit 4 Heat Input Type Input − Btuh (kW)
First Stage Second Stage Output − Btuh (kW) Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Condenser Motor horsepower (W) Fans Motor rpm Total Motor watts Diameter − in. (mm) Number of blades Total Air volume − cfm (L/s) Evaporator Net face area − sq. ft. (m2) total Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Condensate Drain − number and size Expansion device type 3 Indoor Nominal motor output Blower and Max. usable motor output (US Only) Di Drive Motor − Drive kit Selection
Filters Electrical characteristics
Blowerwheelnominaldia.xwidth Type of filter Number and size − in. (mm)
20 and 21 Ton
20 Ton 21 Ton LGA240H2B (R−22) LGA248H2B (R−22) LGA240H4B (R−410A) LGA248H4B (R−410A) High High Constant Air Volume (CAV) Constant Air Volume (CAV) 252,000 (73.8) (R−22) 257,000 (75.3) (R−22) 254,000 (74.4) (R−410A) 257,000 (75.3) (R−410A) 242,000 (70.9) (R−22) 248,000 (72.6) (R−22) 244,000 (71.5) (R−410A) 248,000 (72.6) (R−410A) 7500 (3540) 8,000 (3775) 22.0 (R−22) 23.2 (R−410A) 21.2 11.0 (R−22) 10.5 (R−410A) 11.7 11.8 (R−22) 11.5 (R−410A) 12.3 (R−22) 12.7 (R−410A) 11 lbs. 4 oz. (5.10 kg) 12 lbs. 8 oz. (5.67 kg) 11 lbs. 4 oz. (5.10 kg) 12 lbs. 8 oz. (5.67 kg) 11 lbs. 4 oz. (5.10 kg) 12 lbs. 8 oz. (5.67 kg) 11 lbs. 4 oz. (5.10 kg) 12 lbs. 8 oz. (5.67 kg) 11 lbs. 4 oz. (5.10 kg) 13 lbs. 0 oz. (5.90 kg) 11 lbs. 4 oz. (5.10 kg) 13 lbs. 0 oz. (5.90 kg) 11 lbs. 4 oz. (5.10 kg) 13 lbs. 0 oz. (5.90 kg) 11 lbs. 4 oz. (5.10 kg) 13 lbs. 0 oz. (5.90 kg) 12 lbs. 4 oz. (5.56 kg) --12 lbs. 4 oz. (5.56 kg) --11 lbs. 4 oz. (5.10 kg) --11 lbs. 4 oz. (5.10 kg) --Standard Medium High Standard Medium High 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 80.0% 1 in. 1 7 in. w.g. (1.7 kPa) 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (4) Scroll (4) 56.5 (5.25) 70.6 (6.6) 3/8 (9.5) 3/8 (9.5) 2 2 20 (787) 20 (787) (4) 1/3 (249) (6) 1/3 (249) 1075 1075 1395 2500 (4) 24 (610) (6) 24 (610) 3 3 15,450 (7290) 21,500 (10,145) 22.3 (2.07) 33.3 (3.1) 3/8 (9.5) 3/8 (9.5) 4 3 14 (551) 14 (551) (1) 1 in. NPT coupling (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW) 5.75 hp (4.3 kW) − 8.63 hp (6.4 kW) − 11.5 hp (8.6 kW) 5 hp 5 hp kit #2 − 685 − 865 rpm kit #1 − 660 − 810 rpm kit #3 − 850 − 1045 rpm kit #2 − 770 − 965 rpm kit #4 945 − 1185 rpm kit #6 − 560 − 710 rpm 7.5 hp kit #5 − 945 − 1185 rpm 7.5 hp kit #6 − 1045 − 1285 rpm kit #3 − 715 − 880 rpm kit #7 − 850 − 1045 rpm kit#4 − 770 − 965 rpm 10 hp kit #6 − 1045−1285 rpm 10 hp kit #8 − 1135−1365 rpm kit #3 − 715 − 880 rpm kit #5 − 850 − 1045 rpm (2) 15 x 15 in. (381 x 381 mm) (2) 18 x 15 in. (457 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610x610x51) (12) 20 x 20 x 2 (508 x 508 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase
NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 18
21 Ton
SPECIFICATIONS − HIGH EFFICIENCY COOLING (VAV) General D t Data
Cooling P f Performance
Gas Heating Performance
Nominal Tonnage (kW) Model No. Efficiency Type Blower Type Gross Cooling Capacity − Btuh (kW) 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge Circuit 1 F i h d (R-22) Furnished (R 22) Circuit 2 Circuit 3 Circuit 4 Heat Input Type Btuh (kW)
169,000 (49.5)
234,000 (68.6)
305,000 (89.4)
260,000 (76.2)
360,000 (105.5)
470,000 (137.7)
Output − Second Stage
Btuh (kW)
208,000 (60.9)
288,000 (84.4)
376,000 (110.2)
Indoor Blower and Drive Selection
80.0% 1
Natural
7 in. w.g. (1.7 kPa)
LPG/Propane
11 in. w.g. (2.7 kPa)
Compressor Type (no.)
3
High 2 Stage
Btuh (kW)
Gas Supply Connections
Evaporator Coils
Standard 2 Stage
Input − First Stage
Recommended Gas Supply Pressure
Condenser Fans
257,000 (75.3) 248,000 (72.6) 8,000 (3775) 21.0 11.8 14.7 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) Medium 2 Stage
Input − Second Stage
CSA Thermal Efficiency
Condenser Coils
21 Ton LGA248H2V (R−22) High Variable Air Volume (VAV)
Scroll (4)
Net face area − sq. ft. (m2) total Tube diameter − in. (mm) Number of rows Fins per inch (m) Motor horsepower (W) Motor rpm Total Motor watts Diameter − in. (mm) Number of blades Total Air volume − cfm (L/s) Net face area − sq. ft. (m2) total Tube diameter − in. (mm) Number of rows Fins per inch (m) Condensate Drain − number and size Expansion device type Nominal motor output Motor − Drive kit (maximum rpm, 60hz inverter frequency setting)
70.6 (6.6) 3/8 (9.5) 2 20 (787) (6) 1/3 (249) 1075 2500 (6) 24 (610) 3 21,500 (10,145) 33.3 (3.1) 3/8 (9.5) 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW) 5 hp kit #1 − 810 rpm kit #2 − 965 rpm kit #6 − 710 rpm 7.5 hp kit #3 − 880 rpm kit#4 − 965 rpm 10 hp kit #3 − 880 rpm kit #5 − 1045 rpm
Filters
Blowerwheelnominaldia.xwidth Type of filter Number and size − in. (mm)
Electrical characteristics
(2) 18 x 15 in. (457 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (12) 20 x 20 x 2 (508 x 508 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase
NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 19
SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) Nominal Tonnage (kW)
General D t Data
Model No. Efficiency Type
Cooling Performance
Blower Type Gross Cooling Capacity − Btuh (kW) 1 Net
Gas Heating Performance
Cooling Capacity − Btuh (kW)
ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant g Charge g Circuit 1 F i h d (R-22) Furnished (R 22) Circuit 2 Circuit 3 Circuit 4 Refrigerant g Charge g Circuit 1 F i h d (R-410A) Furnished (R 410A) Circuit 2 Circuit 3 Heat Input Type Input − Btuh (kW)
First Stage Second Stage Output − Btuh (kW) Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Condenser Motor horsepower (W) F Fans Motor rpm Total Motor watts Diameter − in. (mm) Number of blades Total Air volume − cfm (L/s) Evaporator p Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Condensate Drain − number and size Expansion device type 3 Indoor Nominal motor output Bl Blower and d Max. usable motor output (US Only) Drive Motor − Drive kit Selection
Blowerwheelnominaldiameterxwidth Type of filter Number and size − in. (mm) Electrical characteristics Filters
25 and 30 Ton
25 Ton
30 Ton
LGC300H2B (R−22)
LGA360H2B (R−22) LGA360H4B (R−410A)
High
High
Constant Air Volume (CAV) 311,000 (91.1)
Constant Air Volume (CAV) 355,000 (104.0) (R−22) 377,000 (110.5) (R−410A) 300,000 (87.9) 336,000 (98.4) (R−22) 360,000 (105.5) (R−410A) 9500 (4484) 10,500 (4955) 28.4 32.9 (R−22) 37.1 (R−410A) 11.0 10.2 (R−22) 9.7 (R−410A) 11.5 10.6 (R−22) 10.4 (R−410A) 11 lbs. 0 oz. (4.99 kg) 17 lbs. 0 oz (7.71 kg) 11 lbs. 0 oz. (4.99 kg) 17 lbs. 0 oz (7.71 kg) 11 lbs. 0 oz. (4.99 kg) 17 lbs. 0 oz (7.71 kg) 11 lbs. 0 oz. (4.99 kg) ----18 lbs. 8 oz. (8.39 kg) --18 lbs. 8 oz. (8.39 kg) --18 lbs. 8 oz. (8.39 kg) Standard Medium High Standard Medium High 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 80.0% 1 1 7 in. w.g. (1.7 kPa) 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (4) Scroll (3) 70.6 (6.6) 70.6 (6.6) 3/8 (9.5) 3/8 (9.5) 2 2 20 (787) 20 (787) (6) 1/3 (249) (6) 1/3 (249) 1075 1075 2500 2500 (6) 24 (610) (6) 24 (610) 3 3 21,500 (10,145) 21,500 (10,145) 33.3 (3.1) 33.3 (3.1) 3/8 (9.5) 3/8 (9.5) 3 3 14 (551) 14 (551) (1) 1 in. NPT coupling (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW) 5.75 hp (4.3 kW) − 8.63 hp (6.4 kW) − 11.5 hp (8.6 kW) 5 hp 5 hp kit #1 − 660 − 810 rpm kit #1 − 660 − 810 rpm kit #2 − 770 − 965 rpm kit #2 − 770 − 965 rpm kit #6 − 560 − 710 rpm kit #6 − 560 − 710 rpm 7.5 hp 7.5 hp kit #3 − 715 − 880 rpm kit #3 − 715 − 880 rpm kit#4 − 770 − 965 rpm kit#4 − 770 − 965 rpm 10 hp 10 hp kit #3 − 715 − 880 rpm kit #3 − 715 − 880 rpm kit #5 − 850 − 1045 rpm kit #5 − 850 − 1045 rpm (2) 18 x 15 in. (457 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (12) 20 x 20 x 2 (508 x 508 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase
NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Tested at conditions included in with ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 20
25 and 30 Ton
SPECIFICATIONS − HIGH EFFICIENCY COOLING (VAV) General D t Data
Nominal Tonnage (kW) Model No. Efficiency Type
Cooling g P f Performance
Gas Heating Performance
Blower Type Gross Cooling Capacity − Btuh (kW) 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant g Charge g Circuit 1 F i h d (R-22) Furnished (R 22) Circuit 2 Circuit 3 Circuit 4 Heat Input Type
25 Ton
30 Ton
LGC300H2V (R−22)
LGC360H2V (R−22)
High
High
Variable Air Volume (VAV) 311,000 (91.1) 300,000 (87.9) 9000 (4245) 27.8 10.8 13.4 12 lbs. 0 oz. (5.44 kg) 12 lbs. 0 oz. (5.44 kg) 12 lbs. 0 oz. (5.44 kg) 12 lbs. 0 oz. (5.44 kg)
Variable Air Volume (VAV) 355,000 (104.0) 336,000 (98.4) 10,500 (4955) 32.9 10.3 13.0 12 lbs. 0 oz (5.44 kg) 11 lbs. 0 oz (4.99 kg) 11 lbs. 0 oz (4.99 kg) 11 lbs. 0 oz (4.99 kg)
Standard 2 Stage
Medium 2 Stage
High 2 Stage
Standard 2 Stage
Medium 2 Stage
High 2 Stage
Input − First Stage Btuh (kW) 169,000 (49.5) 234,000 (68.6) 305,000 (89.4) 169,000 (49.5) 234,000 (68.6) 305,000 (89.4) Input − Second Stage Btuh (kW) 260,000 (76.2) 360,000 (105.5) 470,000 (137.7) 260,000 (76.2) 360,000 (105.5) 470,000 (137.7) Output − Second Stage Btuh (kW) 208,000 (60.9) 288,000 (84.4) 376,000 (110.2) 208,000 (60.9) 288,000 (84.4) 376,000 (110.2) CSA Thermal Efficiency 80.0% 80.0% Gas Supply Connections 1 1 Recommended Gas Supply Pressure Natural 7 in. w.g. (1.7 kPa) 7 in. w.g. (1.7 kPa) LPG/Propane 11 in. w.g. (2.7 kPa) 11 in. w.g. (2.7 kPa) Compressor Type (no.) Scroll (4) Scroll (4) Condenser Net face area − sq. ft. (m2) total 70.6 (6.6) 70.6 (6.6) C il Coils Tube diameter − in. (mm) 3/8 (9.5) 3/8 (9.5) Number of rows 2 2 Fins per inch (m) 20 (787) 20 (787) Condenser Motor horsepower (W) (6) 1/3 (249) (6) 1/3 (249) F Fans Motor rpm 1075 1075 Total Motor watts 2500 2500 Diameter − in. (mm) (6) 24 (610) (6) 24 (610) Number of blades 3 3 Total Air volume − cfm (L/s) 21,500 (10,145) 21,500 (10,145) Evaporator p Net face area − sq. ft. (m2) total 33.3 (3.1) 33.3 (3.1) C il Coils Tube diameter − in. (mm) 3/8 (9.5) 3/8 (9.5) Number of rows 3 3 Fins per inch (m) 14 (551) 14 (551) Condensate Drain − number and size (1) 1 in. NPT coupling (1) 1 in. NPT coupling Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head 3 Indoor Nominal motor output 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW) Bl Blower and d 5 hp 5 hp Motor − Drive kit Drive kit #1 − 810 rpm kit #1 − 810 rpm (maximum rpm, Selection kit #2 − 965 rpm kit #2 − 965 rpm 60hz inverter frequency setting) kit #6 − 710 rpm kit #6 − 710 rpm 7.5 hp 7.5 hp kit #3 − 880 rpm kit #3 − 880 rpm kit#4 − 965 rpm kit#4 − 965 rpm 10 hp 10 hp kit #3 − 880 rpm kit #3 − 880 rpm kit #5 − 1045 rpm kit #5 − 1045 rpm Blowerwheelnominaldiameterxwidth (2) 18 x 15 in. (457 x 381 mm) Filters Type of filter Disposable, pleated MERV 7 (standard) or MERV 11 (optional) Number and size − in. (mm) (12) 20 x 20 x 2 (508 x 508 x 51) Electrical characteristics 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Tested at conditions included in with ARI Standard 340/360; 95F (35C) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80F (27C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 21
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
13 TON HIGH EFFICIENCY − LGC156H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4160 5200 6240 4160 5200 6240 4160 5200 6240
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 1965 2455 2945 1965 2455 2945 1965 2455 2945
105.6 110.2 113.9 113.2 117.3 120.4 121.4 125.7 128.7
30.9 32.3 33.4 33.2 34.4 35.3 35.6 36.8 37.7
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 4.67 .64 4.69 .69 4.71 .74 4.70 .50 4.73 .53 4.75 .55 4.75 .38 4.77 .39 4.79 .40
80_F 27_C .79 .87 .94 .61 .66 .71 .48 .51 .54
85_F 29_C .94 1.00 1.00 .74 .82 .91 .59 .63 .68
Total Cooling Capacity kBtuh 102.8 107.2 110.7 110.0 114.0 116.8 117.9 121.9 124.7
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 30.1 5.27 .64 31.4 5.29 .70 32.4 5.31 .76 32.2 5.30 .51 33.4 5.32 .53 34.2 5.34 .56 34.6 5.34 .38 35.7 5.36 .39 36.5 5.38 .40
80_F 27_C .80 .89 .96 .62 .67 .73 .49 .52 .55
85_F 29_C .96 1.00 1.00 .76 .84 .92 .59 .64 .70
Total Cooling Capacity kBtuh kW 99.6 103.8 107.2 106.4 110.1 112.8 114.1 117.8 120.4
29.2 30.4 31.4 31.2 32.3 33.1 33.4 34.5 35.3
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.95 .65 5.97 .71 5.99 .77 5.99 .51 6.00 .54 6.02 .57 6.02 .38 6.03 .39 6.05 .40
80_F 27_C .82 .90 .98 .63 .68 .75 .49 .52 .55
85_F 29_C .97 1.00 1.00 .77 .86 .94 .60 .65 .72
Total Cooling Capacity kBtuh kW 96.1 99.9 103.5 102.5 106.0 108.5 109.8 113.3 115.7
28.2 29.3 30.3 30.0 31.1 31.8 32.2 33.2 33.9
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 6.71 .66 .83 .99 6.74 .73 .93 1.00 6.75 .79 .99 1.00 6.74 .52 .64 .79 6.76 .55 .70 .89 6.78 .58 .77 .97 6.78 .38 .50 .61 6.80 .40 .53 .67 6.81 .41 .56 .74
13 TON HIGH EFFICIENCY − LGC156H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4160 5200 6240 4160 5200 6240 4160 5200 6240
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 1965 2455 2945 1965 2455 2945 1965 2455 2945
150.4 156.7 161.9 160.7 166.2 170.2 172.2 177.8 181.6
44.1 45.9 47.4 47.1 48.7 49.9 50.5 52.1 53.2
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 9.03 .68 9.06 .74 9.09 .80 9.09 .53 9.12 .56 9.14 .59 9.15 .40 9.17 .41 9.19 .42
80_F 27_C .84 .92 .99 .66 .71 .77 .52 .55 .58
85_F 29_C .98 1.00 1.00 .79 .88 .96 .63 .69 .74
Total Cooling Capacity kBtuh 145.1 150.9 156.3 154.8 160.0 163.7 165.8 171.0 174.6
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 42.5 10.18 .69 44.2 10.22 .75 45.8 10.25 .82 45.4 10.24 .54 46.9 10.26 .57 48.0 10.29 .60 48.6 10.29 .40 50.1 10.32 .41 51.2 10.34 .43
80_F 27_C .85 .94 1.00 .67 .72 .79 .52 .56 .59
85_F 29_C 1.00 1.00 1.00 .81 .90 .98 .64 .70 .76
Total Cooling Capacity kBtuh kW 139.2 144.8 150.7 148.5 153.3 156.6 159.0 163.6 166.9
40.8 42.4 44.2 43.5 44.9 45.9 46.6 47.9 48.9
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 11.51 .70 11.54 .77 11.54 .84 11.54 .55 11.58 .58 11.60 .62 11.59 .41 11.64 .42 11.64 .43
80_F 27_C .87 .96 1.00 .68 .74 .81 .53 .57 .60
85_F 29_C 1.00 1.00 1.00 .83 .93 1.00 .66 .72 .79
Total Cooling Capacity kBtuh kW 132.9 138.5 144.5 141.6 145.9 149.2 151.7 155.8 158.7
38.9 40.6 42.3 41.5 42.8 43.7 44.5 45.7 46.5
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 12.98 .72 .90 1.00 13.01 .79 .99 1.00 13.02 .87 1.00 1.00 13.01 .56 .70 .86 13.05 .59 .77 .95 13.07 .63 .84 1.00 13.07 .41 .54 .67 13.10 .42 .58 .74 13.12 .44 .62 .81
15 TON STANDARD EFFICIENCY − LGC180S (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4800 6000 7200 4800 6000 7200 4800 6000 7200
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400
123.4 128.2 132.0 131.2 135.4 138.3 139.5 143.7 146.5
36.2 37.6 38.7 38.5 39.7 40.5 40.9 42.1 42.9
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 7.02 .66 7.13 .71 7.20 .77 7.18 .53 7.28 .55 7.34 .58 7.36 .40 7.46 .41 7.53 .42
80_F 27_C .80 .88 .94 .64 .69 .74 .51 .54 .57
85_F 29_C .94 1.00 1.00 .77 .84 .91 .62 .66 .72
Total Cooling Capacity kBtuh 120.2 124.8 128.5 127.7 131.8 134.7 136.0 140.0 142.8
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 35.2 7.72 .67 36.6 7.82 .72 37.7 7.90 .78 37.4 7.88 .53 38.6 7.98 .55 39.5 8.04 .58 39.9 8.06 .40 41.0 8.16 .41 41.9 8.22 .42
80_F 27_C .81 .89 .96 .65 .69 .75 .51 .54 .57
85_F 29_C .95 1.00 1.00 .78 .86 .93 .62 .67 .73
Total Cooling Capacity kBtuh kW 116.3 120.8 124.5 123.7 127.6 130.4 131.8 135.6 138.2
34.1 35.4 36.5 36.3 37.4 38.2 38.6 39.7 40.5
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 8.52 .68 8.62 .73 8.71 .79 8.69 .53 8.78 .56 8.85 .59 8.87 .40 8.97 .41 9.03 .42
80_F 27_C .83 .91 .97 .65 .71 .77 .52 .55 .58
85_F 29_C .97 1.00 1.00 .79 .87 .95 .63 .68 .74
Total Cooling Capacity kBtuh kW 112.1 116.5 120.2 119.2 123.0 125.6 127.1 130.8 133.1
32.9 34.1 35.2 34.9 36.0 36.8 37.2 38.3 39.0
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.45 .69 .85 .98 9.55 .75 .93 1.00 9.63 .81 .99 1.00 9.61 .54 .66 .81 9.71 .57 .72 .89 9.79 .60 .79 .96 9.82 .40 .52 .64 9.90 .41 .55 .70 9.98 .43 .59 .76
15 TON STANDARD EFFICIENCY − LGC180S (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4800 6000 7200 4800 6000 7200 4800 6000 7200
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400
176.3 183.2 188.8 187.6 193.5 197.7 199.8 205.6 209.5
51.7 53.7 55.3 55.0 56.7 57.9 58.6 60.3 61.4
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 12.81 .69 12.96 .74 13.09 .80 13.06 .54 13.20 .57 13.31 .60 13.34 .41 13.49 .42 13.58 .43
80_F 27_C .84 .91 .97 .67 .72 .78 .53 .56 .59
85_F 29_C .97 1.00 1.00 .80 .88 .95 .64 .70 .75
Total Cooling Capacity kBtuh 169.9 176.6 182.2 180.7 186.4 190.4 192.6 198.2 201.8
Comp Motor kW 75_F kW Input 24_C 49.8 14.20 .70 51.8 14.35 .76 53.4 14.48 .82 53.0 14.45 .55 54.6 14.60 .58 55.8 14.72 .61 56.4 14.76 .41 58.1 14.89 .42 59.1 15.01 .43
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 22
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .85 .93 .99 .68 .73 .80 .53 .57 .60
85_F 29_C .98 1.00 1.00 .82 .90 .97 .66 .71 .77
Total Cooling Capacity kBtuh kW 163.3 169.6 175.5 173.6 178.8 182.6 185.1 190.3 193.8
47.9 49.7 51.4 50.9 52.4 53.5 54.2 55.8 56.8
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 15.75 .71 15.93 .78 16.08 .84 16.05 .56 16.19 .59 16.31 .62 16.37 .41 16.51 .43 16.61 .44
80_F 27_C .87 .95 1.00 .69 .75 .82 .54 .58 .61
85_F 29_C 1.00 1.00 1.00 .83 .92 .98 .67 .73 .79
Total Cooling Capacity kBtuh kW 156.8 162.9 169.1 166.5 171.4 174.8 177.5 182.1 185.3
46.0 47.7 49.6 48.8 50.2 51.2 52.0 53.4 54.3
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 17.52 .73 .89 1.00 17.73 .79 .97 1.00 17.91 .86 1.00 1.00 17.83 .56 .70 .85 18.01 .60 .77 .94 18.11 .64 .84 1.00 18.18 .42 .55 .68 18.36 .43 .59 .74 18.45 .44 .63 .81
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
15 TON HIGH EFFICIENCY − LGC180H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4800 6000 7200 4800 6000 7200 4800 6000 7200
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400
128.6 133.8 137.6 137.0 141.7 145.1 146.2 150.9 154.1
37.7 39.2 40.3 40.2 41.5 42.5 42.8 44.2 45.2
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.78 .66 5.82 .71 5.85 .76 5.84 .52 5.87 .55 5.91 .57 5.91 .40 5.95 .41 5.98 .42
80_F 27_C .80 .87 .93 .64 .68 .73 .51 .53 .56
85_F 29_C .93 .99 1.00 .76 .83 .90 .61 .66 .71
Total Cooling Capacity kBtuh 125.2 130.0 133.9 133.3 137.7 140.9 142.0 146.5 149.6
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 36.7 6.47 .67 38.1 6.52 .72 39.2 6.54 .77 39.1 6.53 .53 40.4 6.58 .55 41.3 6.61 .58 41.6 6.61 .40 42.9 6.65 .41 43.8 6.68 .42
80_F 27_C .81 .88 .95 .64 .69 .74 .51 .54 .57
85_F 29_C .94 1.00 1.00 .77 .84 .91 .62 .67 .72
Total Cooling Capacity kBtuh kW 121.4 126.1 129.9 129.1 133.3 136.3 137.7 141.8 144.8
35.6 37.0 38.1 37.8 39.1 39.9 40.4 41.6 42.4
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 7.29 .67 7.32 .73 7.36 .78 7.35 .53 7.39 .56 7.41 .59 7.42 .40 7.46 .41 7.48 .42
80_F 27_C .82 .90 .96 .65 .70 .76 .51 .54 .57
85_F 29_C .96 1.00 1.00 .78 .86 .93 .63 .68 .73
Total Cooling Capacity kBtuh kW 117.2 121.8 125.4 124.7 128.6 131.4 132.9 136.8 139.6
34.3 35.7 36.8 36.5 37.7 38.5 38.9 40.1 40.9
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.22 .68 .84 .97 8.26 .74 .91 1.00 8.29 .80 .98 1.00 8.30 .54 .66 .80 8.32 .57 .72 .88 8.35 .60 .78 .95 8.37 .40 .52 .64 8.40 .41 .55 .69 8.43 .42 .58 .75
15 TON HIGH EFFICIENCY − LGC180H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4800 6000 7200 4800 6000 7200 4800 6000 7200
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400
177.6 184.4 189.9 188.9 195.0 199.5 201.4 207.6 211.8
52.0 54.0 55.7 55.4 57.1 58.5 59.0 60.8 62.1
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 10.86 .69 10.92 .73 10.96 .79 10.96 .54 11.02 .57 11.05 .60 11.06 .41 11.13 .42 11.17 .43
80_F 27_C .82 .90 .96 .66 .71 .76 .52 .55 .58
85_F 29_C .96 1.00 1.00 .79 .86 .93 .64 .69 .74
Total Cooling Capacity kBtuh 171.5 178.1 183.6 182.3 188.1 192.3 194.5 200.2 204.1
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 50.3 12.26 .69 52.2 12.31 .75 53.8 12.36 .80 53.4 12.36 .54 55.1 12.40 .57 56.4 12.46 .60 57.0 12.47 .41 58.7 12.52 .42 59.8 12.56 .43
80_F 27_C .84 .92 .98 .67 .72 .78 .53 .56 .59
85_F 29_C .97 1.00 1.00 .80 .88 .95 .64 .70 .76
Total Cooling Capacity kBtuh kW 165.1 171.4 176.9 175.4 180.9 184.8 187.0 192.5 196.0
48.4 50.2 51.8 51.4 53.0 54.2 54.8 56.4 57.4
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 13.86 .70 13.91 .76 13.97 .82 13.97 .55 14.00 .58 14.06 .61 14.09 .41 14.13 .42 14.19 .44
80_F 27_C .85 .93 .99 .68 .74 .80 .53 .57 .60
85_F 29_C .99 1.00 1.00 .82 .90 .97 .66 .71 .78
Total Cooling Capacity kBtuh kW 158.3 164.3 170.3 168.2 173.2 176.8 179.4 184.4 187.6
46.4 48.2 49.9 49.3 50.8 51.8 52.6 54.0 55.0
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 15.67 .72 .88 1.00 15.75 .78 .96 1.00 15.78 .84 1.00 1.00 15.78 .56 .69 .84 15.84 .59 .76 .92 15.90 .63 .82 .99 15.91 .41 .54 .67 15.96 .43 .58 .73 16.01 .44 .62 .80
15 TON HIGH EFFICIENCY − LGC180H (R−410A/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4800 6000 7200 4800 6000 7200 4800 6000 7200
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400
131.6 137.0 141.2 140.4 145.5 149.0 149.8 155.0 158.6
38.6 40.2 41.4 41.1 42.6 43.7 43.9 45.4 46.5
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.75 .68 5.77 .72 5.79 .77 5.79 .54 5.81 .56 5.83 .59 5.83 .42 5.85 .42 5.87 .43
80_F 27_C .80 .86 .92 .65 .70 .74 .52 .55 .57
85_F 29_C .92 .98 1.00 .77 .83 .89 .63 .67 .72
Total Cooling Capacity kBtuh 126.8 131.9 135.9 135.2 139.9 143.2 144.3 149.1 152.3
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 37.2 6.57 .69 38.7 6.61 .73 39.8 6.63 .78 39.6 6.62 .55 41.0 6.65 .57 42.0 6.68 .60 42.3 6.68 .42 43.7 6.71 .42 44.6 6.74 .43
80_F 27_C .82 .88 .94 .66 .71 .76 .53 .55 .58
85_F 29_C .94 .99 1.00 .78 .85 .91 .64 .68 .73
Total Cooling Capacity kBtuh kW 121.7 126.6 130.5 129.7 134.1 137.2 138.5 142.8 145.8
35.7 37.1 38.2 38.0 39.3 40.2 40.6 41.9 42.7
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 7.51 .70 7.54 .75 7.56 .80 7.56 .55 7.60 .58 7.62 .61 7.62 .42 7.66 .43 7.69 .44
80_F 27_C .83 .90 .96 .67 .72 .78 .53 .56 .59
85_F 29_C .95 1.00 1.00 .80 .87 .93 .65 .70 .75
Total Cooling Capacity kBtuh kW 116.3 120.9 124.7 123.9 127.9 130.8 132.2 136.2 139.0
34.1 35.4 36.5 36.3 37.5 38.3 38.7 39.9 40.7
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.57 .71 .85 .97 8.60 .76 .92 1.00 8.63 .82 .98 1.00 8.63 .56 .69 .82 8.66 .59 .74 .89 8.68 .62 .79 .95 8.69 .42 .54 .66 8.73 .43 .57 .72 8.75 .44 .61 .77
15 TON HIGH EFFICIENCY − LGC180H (R−410A/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4800 6000 7200 4800 6000 7200 4800 6000 7200
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400
182.2 189.5 195.4 194.2 200.8 205.4 207.3 213.8 218.3
53.4 55.5 57.3 56.9 58.8 60.2 60.8 62.7 64.0
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 11.30 .70 11.35 .75 11.38 .80 11.38 .55 11.44 .58 11.47 .61 11.47 .42 11.53 .43 11.58 .44
80_F 27_C .83 .90 .96 .67 .72 .77 .53 .56 .59
85_F 29_C .95 1.00 1.00 .80 .86 .93 .65 .70 .75
Total Cooling Capacity kBtuh 174.1 181.0 186.7 185.5 191.5 195.9 197.9 203.9 208.1
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 51.0 12.89 .71 53.0 12.94 .76 54.7 12.98 .81 54.4 12.99 .56 56.1 13.03 .59 57.4 13.06 .62 58.0 13.08 .42 59.8 13.14 .43 61.0 13.17 .44
80_F 27_C .85 .92 .98 .68 .74 .79 .54 .57 .61
85_F 29_C .97 1.00 1.00 .81 .89 .95 .66 .71 .77
Total Cooling Capacity kBtuh kW 165.4 171.8 177.5 176.1 181.6 185.5 188.0 193.4 196.9
48.5 50.3 52.0 51.6 53.2 54.4 55.1 56.7 57.7
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 14.68 .73 14.72 .78 14.76 .84 14.76 .57 14.81 .60 14.86 .63 14.88 .42 14.91 .43 14.97 .45
80_F 27_C .87 .94 .99 .70 .76 .82 .55 .58 .62
85_F 29_C .99 1.00 1.00 .83 .91 .97 .67 .73 .79
Total Cooling Capacity kBtuh kW 155.8 161.9 168.3 165.8 170.6 174.4 177.1 181.8 185.1
45.7 47.4 49.3 48.6 50.0 51.1 51.9 53.3 54.2
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 16.68 .74 .90 1.00 16.74 .81 .97 1.00 16.75 .87 1.00 1.00 16.76 .58 .72 .86 16.82 .61 .78 .94 16.84 .65 .84 .99 16.85 .43 .56 .69 16.91 .44 .60 .76 16.93 .45 .64 .82
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 23
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
17.5 TON STANDARD EFFICIENCY − LGC210S (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
5600 7000 8400 5600 7000 8400 5600 7000 8400
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965
104.0 108.0 111.0 110.4 113.8 116.4 117.4 120.8 123.2
30.5 31.7 32.5 32.4 33.4 34.1 34.4 35.4 36.1
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.70 .64 5.80 .69 5.86 .75 5.86 .50 5.92 .53 6.00 .56 6.02 .38 6.10 .39 6.16 .40
80_F 27_C .79 .87 .95 .62 .66 .72 .49 .52 .55
85_F 29_C .94 1.00 1.00 .75 .84 .91 .60 .64 .70
Total Cooling Capacity kBtuh 100.8 104.4 107.6 107.0 110.2 112.4 113.8 116.8 119.0
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 29.5 6.34 .65 30.6 6.44 .70 31.5 6.50 .76 31.4 6.48 .51 32.3 6.58 .54 32.9 6.62 .56 33.4 6.66 .38 34.2 6.74 .39 34.9 6.80 .40
80_F 27_C .81 .89 .96 .63 .67 .74 .49 .52 .56
85_F 29_C .96 1.00 1.00 .77 .86 .93 .60 .65 .71
Total Cooling Capacity kBtuh kW 97.2 100.8 104.0 103.2 106.2 108.4 109.8 112.6 114.8
28.5 29.5 30.5 30.2 31.1 31.8 32.2 33.0 33.6
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 7.06 .66 7.14 .72 7.22 .78 7.20 .51 7.30 .54 7.34 .57 7.38 .39 7.48 .39 7.54 .41
80_F 27_C .82 .91 .98 .63 .69 .76 .50 .53 .56
85_F 29_C .98 1.00 1.00 .78 .88 .95 .61 .67 .73
Total Cooling Capacity kBtuh kW 93.6 97.0 100.2 99.2 102.0 104.0 105.4 108.2 110.2
27.4 28.4 29.4 29.1 29.9 30.5 30.9 31.7 32.3
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.88 .67 .84 .99 7.96 .74 .93 1.00 8.06 .80 .99 1.00 8.04 .52 .65 .80 8.12 .55 .71 .90 8.18 .58 .78 .97 8.22 .39 .51 .63 8.30 .40 .54 .68 8.38 .41 .57 .76
17.5 TON STANDARD EFFICIENCY − LGC210S (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
5600 7000 8400 5600 7000 8400 5600 7000 8400
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965
202.0 209.4 215.8 214.4 220.6 225.2 228.0 234.0 238.4
59.2 61.4 63.2 62.8 64.7 66.0 66.8 68.6 69.9
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 14.24 .69 14.40 .74 14.56 .80 14.52 .54 14.72 .57 14.82 .60 14.88 .40 15.08 .42 15.20 .43
80_F 27_C .84 .92 .98 .67 .72 .78 .52 .56 .59
85_F 29_C .98 1.00 1.00 .80 .89 .96 .64 .70 .76
Total Cooling Capacity kBtuh 194.4 201.4 208.0 206.0 212.0 216.2 219.2 224.8 229.0
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 57.0 15.88 .70 59.0 16.06 .76 61.0 16.26 .82 60.4 16.22 .55 62.1 16.38 .58 63.4 16.50 .61 64.2 16.58 .41 65.9 16.74 .42 67.1 16.90 .43
80_F 27_C .86 .94 1.00 .68 .73 .80 .53 .57 .60
85_F 29_C .99 1.00 1.00 .82 .91 .98 .66 .71 .78
Total Cooling Capacity kBtuh kW 186.2 193.2 199.8 197.0 202.8 206.6 209.8 215.2 218.6
54.6 56.6 58.6 57.7 59.4 60.5 61.5 63.1 64.1
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 17.76 .72 17.96 .78 18.16 .85 18.10 .55 18.28 .59 18.40 .62 18.48 .41 18.64 .42 18.80 .44
80_F 27_C .88 .96 1.00 .69 .75 .82 .54 .58 .62
85_F 29_C 1.00 1.00 1.00 .84 .93 .99 .67 .73 .80
Total Cooling Capacity kBtuh kW 177.4 184.4 191.2 187.6 192.6 196.6 199.6 204.6 207.6
52.0 54.0 56.0 55.0 56.4 57.6 58.5 60.0 60.8
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 19.92 .73 .91 1.00 20.12 .80 .99 1.00 20.34 .87 1.00 1.00 20.24 .56 .71 .87 20.46 .60 .78 .96 20.54 .64 .85 1.00 20.66 .41 .55 .69 20.82 .43 .59 .76 20.94 .44 .63 .83
17.5 TON HIGH EFFICIENCY − LGC210H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
5600 7000 8400 5600 7000 8400 5600 7000 8400
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965
109.2 114.0 117.6 116.6 120.8 123.8 124.8 129.0 131.8
32.0 33.4 34.5 34.2 35.4 36.3 36.6 37.8 38.6
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 4.94 .65 4.98 .70 5.00 .76 5.00 .51 5.02 .54 5.06 .57 5.06 .39 5.10 .40 5.12 .41
80_F 27_C .80 .89 .97 .63 .67 .74 .49 .52 .56
85_F 29_C .95 1.00 1.00 .76 .85 .93 .60 .65 .71
Total Cooling Capacity kBtuh 106.2 110.6 114.2 113.2 117.0 119.8 121.0 124.8 127.4
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 31.1 5.58 .66 32.4 5.60 .72 33.5 5.64 .78 33.2 5.62 .51 34.3 5.66 .55 35.1 5.68 .58 35.5 5.70 .39 36.6 5.72 .40 37.3 5.76 .41
80_F 27_C .81 .91 .98 .63 .69 .75 .50 .53 .56
85_F 29_C .97 1.00 1.00 .77 .86 .95 .61 .66 .72
Total Cooling Capacity kBtuh kW 102.6 106.8 110.6 109.4 113.0 115.6 116.8 120.4 122.8
30.1 31.3 32.4 32.1 33.1 33.9 34.2 35.3 36.0
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 6.28 .67 6.32 .73 6.34 .80 6.34 .52 6.38 .55 6.40 .58 6.40 .39 6.44 .40 6.46 .41
80_F 27_C .83 .93 1.00 .64 .70 .77 .50 .54 .57
85_F 29_C .98 1.00 1.00 .79 .89 .97 .62 .67 .74
Total Cooling Capacity kBtuh kW 98.8 102.8 107.0 105.2 108.6 111.0 112.4 115.6 117.8
29.0 30.1 31.4 30.8 31.8 32.5 32.9 33.9 34.5
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW 75_F 80_F 85_F Input 24_C 27_C 29_C 7.08 .68 .85 1.00 7.12 .75 .95 1.00 7.14 .82 1.00 1.00 7.14 .53 .65 .81 7.18 .56 .72 .91 7.20 .60 .79 .99 7.20 .39 .51 .63 7.24 .40 .55 .69 7.26 .42 .59 .77
17.5 TON HIGH EFFICIENCY − LGC210H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
5600 7000 8400 5600 7000 8400 5600 7000 8400
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965
207.7 216.4 223.8 221.4 228.9 234.2 236.6 244.1 249.0
60.9 63.4 65.6 64.9 67.1 68.6 69.3 71.5 73.0
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 12.74 .70 12.82 .76 12.86 .82 12.84 .55 12.92 .58 12.96 .62 12.98 .41 13.04 .42 13.08 .44
80_F 27_C .85 .93 .99 .68 .74 .80 .53 .57 .60
85_F 29_C .98 1.00 1.00 .81 .90 .97 .65 .71 .77
Total Cooling Capacity kBtuh 200.3 208.4 216.4 213.2 220.1 225.2 228.0 234.5 239.0
Comp Motor kW 75_F kW Input 24_C 58.7 14.36 .71 61.1 14.44 .78 63.4 14.50 .84 62.5 14.48 .56 64.5 14.56 .59 66.0 14.60 .63 66.8 14.60 .41 68.7 14.68 .43 70.0 14.72 .44
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 24
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .87 .95 1.00 .69 .75 .81 .54 .58 .62
85_F 29_C 1.00 1.00 1.00 .83 .92 .99 .66 .73 .79
Total Cooling Capacity kBtuh kW 192.0 199.9 208.4 204.3 210.8 215.3 218.4 224.4 228.6
56.3 58.6 61.1 59.9 61.8 63.1 64.0 65.8 67.0
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 16.20 .73 16.30 .79 16.34 .86 16.32 .56 16.38 .60 16.42 .64 16.46 .42 16.50 .43 16.54 .45
80_F 27_C .89 .97 1.00 .70 .77 .84 .55 .59 .63
85_F 29_C 1.00 1.00 1.00 .85 .94 1.00 .68 .74 .81
Total Cooling Capacity kBtuh kW 183.1 191.2 199.6 194.7 200.8 205.2 208.0 213.7 217.6
53.7 56.0 58.5 57.1 58.8 60.1 61.0 62.6 63.8
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 18.30 .74 .91 1.00 18.36 .82 .99 1.00 18.44 .89 1.00 1.00 18.42 .57 .72 .87 18.48 .61 .79 .97 18.52 .65 .86 1.00 18.56 .42 .56 .69 18.60 .44 .60 .76 18.64 .45 .65 .84
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
20 TON STANDARD EFFICIENCY − LGC240S (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6400 8000 9600 6400 8000 9600 6400 8000 9600
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530
118.8 123.0 126.4 126.0 129.8 132.4 133.8 137.4 140.0
34.8 36.0 37.0 36.9 38.0 38.8 39.2 40.3 41.0
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 6.72 .60 6.80 .65 6.86 .71 6.86 .48 6.92 .50 6.98 .52 7.02 .36 7.08 .37 7.14 .38
80_F 27_C .76 .85 .93 .58 .62 .68 .46 .49 .51
85_F 29_C .92 1.00 1.00 .72 .81 .89 .56 .61 .66
Total Cooling Capacity kBtuh 115.8 120.0 123.4 122.8 126.4 129.0 130.6 134.2 136.6
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 33.9 7.38 .61 35.2 7.46 .66 36.2 7.54 .72 36.0 7.52 .48 37.0 7.58 .50 37.8 7.64 .53 38.3 7.66 .36 39.3 7.74 .37 40.0 7.80 .38
80_F 27_C .77 .86 .94 .59 .63 .70 .46 .49 .52
85_F 29_C .94 1.00 1.00 .73 .82 .91 .56 .61 .67
Total Cooling Capacity kBtuh kW 112.0 116.2 119.6 119.0 122.6 125.0 126.6 130.0 132.4
32.8 34.1 35.1 34.9 35.9 36.6 37.1 38.1 38.8
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 8.14 .62 8.24 .67 8.30 .74 8.28 .48 8.36 .51 8.42 .54 8.44 .36 8.52 .37 8.56 .38
80_F 27_C .79 .89 .96 .59 .64 .72 .47 .50 .53
85_F 29_C .96 1.00 1.00 .74 .84 .93 .57 .62 .69
Total Cooling Capacity kBtuh kW 108.0 112.2 115.6 114.6 118.0 120.4 122.2 125.4 127.6
31.7 32.9 33.9 33.6 34.6 35.3 35.8 36.8 37.4
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.02 .62 .81 .98 9.12 .69 .91 1.00 9.18 .76 .98 1.00 9.16 .49 .60 .76 9.26 .51 .66 .87 9.30 .54 .74 .95 9.32 .36 .47 .58 9.40 .37 .50 .63 9.46 .39 .53 .71
20 TON STANDARD EFFICIENCY − LGC240S (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6400 8000 9600 6400 8000 9600 6400 8000 9600
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530
230.6 239.2 246.2 245.0 252.2 257.4 260.6 267.6 272.6
67.6 70.1 72.2 71.8 73.9 75.4 76.4 78.4 79.9
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 16.66 .69 16.86 .74 16.98 .80 16.94 .54 17.10 .57 17.24 .60 17.28 .41 17.44 .42 17.52 .43
80_F 27_C .85 .93 1.00 .67 .72 .78 .52 .56 .59
85_F 29_C .99 1.00 1.00 .81 .89 .97 .64 .70 .75
Total Cooling Capacity kBtuh 222.4 231.0 238.0 236.0 243.0 248.0 251.6 258.2 262.8
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 65.2 18.46 .70 67.7 18.66 .76 69.8 18.80 .82 69.2 18.76 .55 71.2 18.94 .58 72.7 19.04 .61 73.7 19.08 .41 75.7 19.24 .42 77.0 19.36 .43
80_F 27_C .86 .95 1.00 .68 .73 .80 .53 .57 .60
85_F 29_C 1.00 1.00 1.00 .82 .91 .99 .65 .71 .77
Total Cooling Capacity kBtuh kW 213.8 222.0 229.4 227.0 233.4 238.4 241.8 248.0 252.4
62.7 65.1 67.2 66.5 68.4 69.9 70.9 72.7 74.0
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 20.54 .71 20.70 .78 20.88 .84 20.82 .55 21.00 .59 21.12 .62 21.18 .41 21.36 .42 21.46 .44
80_F 27_C .88 .97 1.00 .69 .75 .82 .54 .58 .61
85_F 29_C 1.00 1.00 1.00 .84 .94 1.00 .67 .73 .79
Total Cooling Capacity kBtuh kW 205.4 213.4 220.8 217.6 223.8 228.4 232.0 237.8 241.8
60.2 62.5 64.7 63.8 65.6 66.9 68.0 69.7 70.9
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 22.84 .73 .91 1.00 23.02 .80 .99 1.00 23.24 .87 1.00 1.00 23.18 .56 .70 .87 23.34 .60 .77 .96 23.46 .63 .84 1.00 23.58 .41 .55 .68 23.72 .43 .58 .74 23.84 .44 .62 .82
20 TON HIGH EFFICIENCY − LGA240H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6400 8000 9600 6400 8000 9600 6400 8000 9600
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530
126.6 131.6 135.8 134.6 139.2 142.4 143.6 148.0 151.2
37.1 38.6 39.8 39.4 40.8 41.7 42.1 43.4 44.3
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 6.26 .63 .78 .94 6.32 .68 .87 1.00 6.36 .74 .95 1.00 6.34 .50 .61 .74 6.40 .52 .65 .83 6.42 .55 .72 .91 6.44 .38 .48 .59 6.48 .39 .51 .63 6.52 .40 .54 .69
75_F (24_C) Total Cooling Capacity kBtuh kW 122.8 127.8 131.8 130.6 134.8 138.0 139.4 143.4 146.4
36.0 37.5 38.6 38.3 39.5 40.4 40.9 42.0 42.9
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.04 .64 .80 .95 7.08 .69 .89 1.00 7.14 .76 .97 1.00 7.12 .50 .62 .75 7.18 .53 .67 .85 7.20 .56 .73 .93 7.22 .38 .49 .59 7.28 .39 .52 .64 7.30 .40 .55 .70
85_F (29_C) Total Cooling Capacity kBtuh kW 118.8 123.6 127.6 126.4 130.4 133.4 134.8 138.6 141.4
34.8 36.2 37.4 37.0 38.2 39.1 39.5 40.6 41.4
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.94 .65 .81 .97 8.00 .71 .91 1.00 8.04 .78 .98 1.00 8.02 .51 .62 .77 8.08 .54 .68 .87 8.12 .57 .75 .95 8.14 .38 .49 .60 8.18 .39 .52 .66 8.24 .40 .56 .72
95_F (35_C) Total Cooling Capacity kBtuh kW 114.8 119.2 123.4 121.8 125.6 128.4 129.8 133.6 136.0
33.6 34.9 36.2 35.7 36.8 37.6 38.0 39.2 39.9
Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.98 .66 .83 .99 9.04 .73 .93 1.00 9.10 .80 1.00 1.00 9.08 .51 .63 .79 9.13 .54 .70 .89 9.18 .58 .77 .97 9.20 .38 .50 .61 9.24 .39 .53 .67 9.28 .41 .57 .74
20 TON HIGH EFFICIENCY − LGA240H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6400 8000 9600 6400 8000 9600 6400 8000 9600
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530
238.4 248.0 256.0 253.4 261.6 267.5 270.3 278.1 283.6
69.9 72.7 75.0 74.3 76.7 78.4 79.2 81.5 83.1
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 15.72 .70 .85 .99 15.84 .75 .93 1.00 15.92 .81 1.00 1.00 15.89 .55 .67 .81 16.00 .58 .73 .89 16.08 .61 .79 .97 16.12 .41 .53 .65 16.20 .42 .56 .70 16.32 .43 .60 .76
95_F (35_C) Total Cooling Capacity kBtuh kW 230.2 239.2 247.6 244.3 252.0 257.6 260.5 268.0 272.9
67.5 70.1 72.6 71.6 73.9 75.5 76.3 78.5 80.0
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 17.80 .71 .86 1.00 17.90 .77 .95 1.00 18.02 .83 1.00 1.00 17.98 .55 .68 .82 18.09 .58 .74 .91 18.18 .62 .81 .99 18.22 .41 .53 .66 18.30 .42 .57 .72 18.39 .44 .61 .78
105_F (41_C) Total Cooling Capacity kBtuh kW 221.2 230.0 238.6 234.8 241.9 247.1 250.4 257.2 261.7
64.8 67.4 69.9 68.8 70.9 72.4 73.4 75.4 76.7
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.16 .72 .88 1.00 20.28 .78 .97 1.00 20.40 .85 1.00 1.00 20.32 .56 .69 .84 20.48 .59 .76 .94 20.56 .63 .83 1.00 20.60 .41 .54 .67 20.72 .43 .58 .73 20.79 .44 .62 .81
115_F (46_C) Total Cooling Capacity kBtuh kW 211.5 220.2 229.4 224.4 231.0 236.0 239.5 245.7 249.9
62.0 64.5 67.2 65.8 67.7 69.2 70.2 72.0 73.2
Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 22.82 .73 .91 1.00 22.96 .81 .99 1.00 23.09 .88 1.00 1.00 23.02 .57 .71 .87 23.18 .60 .78 .96 23.24 .64 .85 1.00 23.28 .42 .55 .69 23.40 .43 .59 .75 23.48 .45 .64 .83
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 25
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
20 TON HIGH EFFICIENCY − LGA240H (R−410A/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6400 8000 9600 6400 8000 9600 6400 8000 9600
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530
133.0 138.4 142.6 141.4 146.4 149.8 150.8 155.6 159.0
39.0 40.6 41.8 41.4 42.9 43.9 44.2 45.6 46.6
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 6.30 .67 6.36 .72 6.38 .77 6.36 .53 6.42 .56 6.46 .58 6.46 .41 6.50 .41 6.54 .42
80_F 27_C .80 .87 .94 .65 .69 .74 .51 .54 .57
85_F 29_C .93 1.00 1.00 .76 .84 .91 .62 .67 .72
Total Cooling Capacity kBtuh 128.0 133.2 137.2 136.0 140.6 144.0 145.0 149.4 152.6
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 37.5 7.18 .68 39.0 7.24 .73 40.2 7.28 .78 39.9 7.26 .54 41.2 7.32 .56 42.2 7.36 .59 42.5 7.36 .41 43.8 7.42 .42 44.7 7.46 .43
80_F 27_C .82 .89 .95 .66 .70 .76 .52 .55 .58
85_F 29_C .95 1.00 1.00 .78 .86 .93 .63 .68 .74
Total Cooling Capacity kBtuh kW 122.6 127.6 131.6 130.4 134.6 137.6 139.0 143.0 145.8
35.9 37.4 38.6 38.2 39.4 40.3 40.7 41.9 42.7
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 8.20 .69 8.24 .75 8.30 .80 8.28 .54 8.34 .57 8.38 .60 8.38 .41 8.46 .42 8.48 .43
80_F 27_C .83 .91 .97 .67 .72 .78 .52 .56 .59
85_F 29_C .97 1.00 1.00 .80 .88 .95 .64 .70 .76
Total Cooling Capacity kBtuh kW 117.0 121.6 125.6 124.2 128.2 131.0 132.4 136.2 138.8
34.3 35.6 36.8 36.4 37.6 38.4 38.8 39.9 40.7
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.34 .70 .85 .98 9.40 .77 .93 1.00 9.44 .83 .99 1.00 9.42 .55 .68 .82 9.48 .58 .74 .90 9.52 .62 .80 .97 9.54 .41 .53 .66 9.58 .42 .57 .71 9.62 .44 .61 .78
20 TON HIGH EFFICIENCY − LGA240H (R−410A/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6400 8000 9600 6400 8000 9600 6400 8000 9600
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530
245.5 255.5 263.5 261.1 269.5 275.6 278.3 286.4 292.0
71.9 74.9 77.2 76.5 79.0 80.8 81.6 83.9 85.6
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 16.40 .69 16.48 .74 16.60 .80 16.56 .54 16.68 .57 16.76 .60 16.76 .41 16.92 .42 16.96 .43
80_F 27_C .83 .91 .97 .67 .72 .78 .52 .56 .59
85_F 29_C .96 1.00 1.00 .79 .87 .95 .64 .70 .75
Total Cooling Capacity kBtuh 234.3 243.5 251.6 248.7 256.7 262.4 265.1 272.8 277.9
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 68.7 18.68 .70 71.4 18.79 .76 73.7 18.88 .82 72.9 18.84 .55 75.2 18.96 .58 76.9 19.04 .62 77.7 19.08 .41 79.9 19.16 .42 81.4 19.25 .44
80_F 27_C .85 .93 .99 .68 .74 .80 .53 .57 .61
85_F 29_C .98 1.00 1.00 .81 .90 .97 .66 .71 .78
Total Cooling Capacity kBtuh kW 221.9 230.7 239.5 235.5 242.4 248.0 251.2 257.6 262.4
65.0 67.6 70.2 69.0 71.0 72.7 73.6 75.5 76.9
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 21.20 .72 21.32 .78 21.44 .85 21.40 .56 21.52 .59 21.56 .63 21.59 .41 21.72 .43 21.76 .44
80_F 27_C .88 .96 1.00 .70 .76 .83 .54 .58 .62
85_F 29_C 1.00 1.00 1.00 .84 .93 .99 .67 .73 .80
Total Cooling Capacity kBtuh kW 208.4 217.1 226.3 221.1 227.6 232.4 236.0 241.7 246.0
61.1 63.6 66.3 64.8 66.7 68.1 69.2 70.8 72.1
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 24.08 .74 .91 1.00 24.16 .81 .99 1.00 24.28 .88 1.00 1.00 24.24 .57 .72 .87 24.32 .61 .79 .96 24.40 .65 .86 1.00 24.43 .42 .56 .69 24.52 .43 .60 .76 24.59 .45 .64 .84
21 TON HIGH EFFICIENCY − LGA248H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6720 8400 10080 6720 8400 10080 6720 8400 10080
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760
123.2 128.1 132.0 131.1 135.6 138.9 139.9 144.4 147.5
36.1 37.5 38.7 38.4 39.7 40.7 41.0 42.3 43.2
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.56 .58 5.59 .63 5.63 .70 5.61 .46 5.65 .48 5.68 .50 5.69 .35 5.72 .35 5.75 .36
80_F 27_C .74 .84 .93 .56 .60 .66 .44 .47 .49
85_F 29_C .92 1.00 1.00 .69 .79 .89 .54 .58 .63
Total Cooling Capacity kBtuh 119.8 124.6 128.3 127.5 131.7 134.8 136.0 140.3 143.1
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 35.1 6.23 .59 36.5 6.25 .64 37.6 6.29 .71 37.4 6.29 .46 38.6 6.32 .48 39.5 6.34 .51 39.9 6.35 .35 41.1 6.39 .36 41.9 6.41 .37
80_F 27_C .76 .86 .95 .56 .61 .68 .45 .47 .50
85_F 29_C .94 1.00 1.00 .71 .81 .91 .54 .59 .65
Total Cooling Capacity kBtuh kW 116.1 120.7 124.6 123.6 127.5 130.4 131.7 135.8 138.5
34.0 35.4 36.5 36.2 37.4 38.2 38.6 39.8 40.6
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 7.00 .59 7.03 .66 7.06 .73 7.06 .46 7.09 .49 7.12 .52 7.13 .35 7.15 .36 7.19 .37
80_F 27_C .77 .88 .97 .57 .62 .70 .45 .48 .51
85_F 29_C .96 1.00 1.00 .72 .83 .93 .55 .60 .67
Total Cooling Capacity kBtuh kW 112.2 116.5 120.5 119.3 123.0 125.7 127.3 130.9 133.4
32.9 34.1 35.3 35.0 36.0 36.8 37.3 38.4 39.1
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.89 .60 .79 .98 7.93 .67 .91 1.00 7.95 .75 .99 1.00 7.95 .47 .58 .74 7.99 .50 .64 .86 8.01 .52 .72 .96 8.02 .35 .45 .56 8.06 .36 .49 .61 8.09 .37 .52 .69
21 TON HIGH EFFICIENCY − LGA248H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6720 8400 10080 6720 8400 10080 6720 8400 10080
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760
244.2 253.6 261.8 259.8 268.2 274.0 277.0 285.4 291.0
71.6 74.3 76.7 76.1 78.6 80.3 81.2 83.6 85.3
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 14.08 .69 14.14 .75 14.22 .80 14.20 .54 14.26 .57 14.34 .61 14.34 .41 14.42 .42 14.46 .43
80_F 27_C .84 .92 .98 .67 .72 .78 .53 .56 .60
85_F 29_C .97 1.00 1.00 .80 .88 .95 .64 .70 .76
Total Cooling Capacity kBtuh 235.8 245.0 253.2 250.8 258.8 264.4 267.4 275.2 280.4
Comp Motor kW 75_F kW Input 24_C 69.1 15.88 .70 71.8 15.94 .76 74.2 16.02 .82 73.5 16.00 .55 75.8 16.06 .58 77.5 16.12 .62 78.4 16.14 .41 80.7 16.22 .42 82.2 16.26 .44
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 26
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .85 .93 .99 .68 .74 .80 .53 .57 .60
85_F 29_C .99 1.00 1.00 .81 .90 .97 .65 .71 .77
Total Cooling Capacity kBtuh kW 227.2 236.0 244.4 241.4 248.8 254.0 257.4 264.6 269.4
66.6 69.2 71.6 70.7 72.9 74.4 75.4 77.5 79.0
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 17.94 .71 18.02 .78 18.06 .84 18.06 .56 18.14 .59 18.20 .63 18.22 .41 18.28 .43 18.34 .44
80_F 27_C .87 .95 1.00 .69 .75 .82 .54 .58 .62
85_F 29_C 1.00 1.00 1.00 .83 .92 .99 .67 .73 .79
Total Cooling Capacity kBtuh kW 217.8 226.4 235.4 231.2 238.2 243.2 246.8 253.2 257.8
63.8 66.4 69.0 67.8 69.8 71.3 72.3 74.2 75.6
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.30 .73 .89 1.00 20.38 .80 .97 1.00 20.46 .86 1.00 1.00 20.42 .56 .70 .85 20.50 .60 .77 .94 20.56 .64 .84 1.00 20.58 .42 .55 .68 20.66 .43 .59 .75 20.70 .44 .63 .82
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
21 TON HIGH EFFICIENCY − LGA248H (R−410A/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6720 8400 10080 6720 8400 10080 6720 8400 10080
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760
128.2 133.5 137.6 136.6 141.5 144.8 145.9 150.7 153.9
37.6 39.1 40.3 40.0 41.5 42.4 42.8 44.2 45.1
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.25 .54 5.29 .59 5.33 .66 5.31 .43 5.35 .45 5.38 .47 5.39 .33 5.43 .33 5.46 .34
80_F 27_C .71 .82 .92 .52 .56 .63 .41 .44 .46
85_F 29_C .91 1.00 1.00 .66 .77 .87 .50 .54 .59
Total Cooling Capacity kBtuh 123.4 128.4 132.5 131.5 136.0 139.1 140.4 144.8 147.8
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 36.2 6.08 .55 37.6 6.11 .61 38.8 6.15 .69 38.5 6.14 .43 39.9 6.17 .46 40.8 6.21 .48 41.1 6.22 .33 42.4 6.26 .33 43.3 6.29 .34
80_F 27_C .74 .85 .95 .53 .57 .65 .42 .44 .47
85_F 29_C .94 1.00 1.00 .68 .80 .91 .51 .55 .62
Total Cooling Capacity kBtuh kW 118.3 123.0 127.2 126.0 130.1 133.0 134.6 138.6 141.3
34.7 36.0 37.3 36.9 38.1 39.0 39.4 40.6 41.4
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 6.95 .56 6.99 .63 7.03 .71 7.02 .44 7.06 .46 7.09 .49 7.11 .33 7.15 .34 7.18 .35
80_F 27_C .76 .88 .98 .54 .59 .68 .42 .45 .48
85_F 29_C .97 1.00 1.00 .71 .83 .94 .52 .57 .65
Total Cooling Capacity kBtuh kW 112.9 117.4 121.7 120.2 123.9 126.6 128.3 132.0 134.4
33.1 34.4 35.7 35.2 36.3 37.1 37.6 38.7 39.4
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.91 .57 .80 1.00 7.97 .66 .92 1.00 7.99 .75 1.00 1.00 7.99 .44 .55 .74 8.03 .47 .62 .87 8.05 .50 .72 .98 8.07 .33 .43 .53 8.11 .34 .46 .59 8.15 .35 .49 .68
21 TON HIGH EFFICIENCY − LGA248H (R−410A/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6720 8400 10080 6720 8400 10080 6720 8400 10080
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760
247.6 257.2 266.0 263.4 272.0 278.2 281.4 289.8 295.4
72.6 75.4 78.0 77.2 79.7 81.5 82.5 84.9 86.6
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 13.94 .66 14.02 .72 14.10 .78 14.08 .52 14.16 .55 14.22 .58 14.24 .39 14.34 .40 14.40 .41
80_F 27_C .82 .92 .99 .64 .69 .76 .50 .54 .57
85_F 29_C .98 1.00 1.00 .78 .87 .96 .62 .67 .73
Total Cooling Capacity kBtuh 236.2 245.4 254.4 251.2 259.0 264.6 268.2 275.6 280.8
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 69.2 15.86 .68 71.9 15.98 .74 74.6 16.02 .81 73.6 16.02 .53 75.9 16.10 .56 77.5 16.16 .59 78.6 16.18 .39 80.8 16.26 .40 82.3 16.34 .42
80_F 27_C .84 .94 1.00 .65 .71 .78 .51 .55 .58
85_F 29_C 1.00 1.00 1.00 .80 .90 .98 .63 .69 .76
Total Cooling Capacity kBtuh kW 223.6 232.8 242.4 237.8 244.8 250.0 253.8 260.8 265.2
65.5 68.2 71.0 69.7 71.7 73.3 74.4 76.4 77.7
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 18.06 .69 18.14 .77 18.22 .84 18.18 .53 18.26 .57 18.30 .61 18.36 .39 18.42 .41 18.48 .42
80_F 27_C .88 .97 1.00 .67 .74 .82 .52 .56 .60
85_F 29_C 1.00 1.00 1.00 .83 .94 1.00 .65 .71 .79
Total Cooling Capacity kBtuh kW 210.2 219.8 229.4 223.2 229.8 234.6 238.4 244.4 248.4
61.6 64.4 67.2 65.4 67.3 68.8 69.9 71.6 72.8
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.50 .71 .92 1.00 20.58 .80 1.00 1.00 20.66 .88 1.00 1.00 20.62 .55 .69 .87 20.70 .59 .77 .98 20.74 .63 .86 1.00 20.80 .40 .53 .67 20.86 .41 .58 .74 20.90 .43 .62 .83
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 27
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
21 TON HIGH EFFICIENCY − LGA248H2V (R−22/VAV) − COOLING CAPACITY − ONE COMPRESSOR OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperat ure
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW
1680 795 2100 990 2520 1190 1680 795 2100 990 2520 1190 1680 795 2100 990 2520 1190
49.3 52.9 55.4 53.0 56.7 59.3 56.9 60.8 63.5
14.4 15.5 16.2 15.5 16.6 17.4 16.7 17.8 18.6
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 4.32 .64 4.36 .65 4.38 .67 4.36 .53 4.40 .53 4.43 .54 4.40 .43 4.45 .43 4.48 .42
80_F 27_C .72 .74 .77 .61 .62 .64 .50 .51 .52
Total Cooling Capacity
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 85_F 75_F kBtuh kW Input 29_C 24_C .80 48.1 14.1 4.84 .64 .84 51.4 15.1 4.88 .65 .88 53.8 15.8 4.91 .67 .68 51.7 15.2 4.88 .53 .71 55.1 16.1 4.92 .53 .74 57.6 16.9 4.95 .54 .57 55.5 16.3 4.93 .43 .59 59.1 17.3 4.97 .43 .61 61.7 18.1 5.00 .42
80_F 27_C .72 .75 .78 .61 .62 .65 .50 .51 .52
Total Cooling Capacity
85_F kBtuh kW 29_C .80 46.7 13.7 .84 49.9 14.6 .89 52.1 15.3 .68 50.2 14.7 .71 53.4 15.6 .75 55.7 16.3 .58 53.9 15.8 .59 57.3 16.8 .62 59.6 17.5
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.45 .64 5.49 .66 5.52 .68 5.50 .53 5.53 .54 5.56 .55 5.54 .43 5.58 .42 5.61 .42
80_F 27_C .73 .76 .79 .61 .63 .65 .50 .51 .52
Total Cooling Capacity
85_F kBtuh kW 29_C .81 45.2 13.2 .85 48.1 14.1 .90 50.2 14.7 .69 48.6 14.2 .72 51.6 15.1 .76 53.7 15.7 .58 52.1 15.3 .60 55.3 16.2 .62 57.5 16.9
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 6.16 .64 .73 .82 6.19 .66 .77 .87 6.22 .69 .80 .92 6.20 .53 .61 .69 6.24 .54 .63 .73 6.26 .55 .66 .77 6.25 .43 .51 .58 6.28 .42 .52 .60 6.32 .43 .53 .63
21 TON HIGH EFFICIENCY − LGA248H2V (R−22/VAV) − COOLING CAPACITY − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
3570 4200 4830 3570 4200 4830 3570 4200 4830
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 1685 1980 2280 1685 1980 2280 1685 1980 2280
135.1 139.0 142.2 144.3 147.9 150.7 154.0 157.8 160.6
39.6 40.7 41.7 42.3 43.3 44.2 45.1 46.2 47.1
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 7.45 .73 7.49 .76 7.52 .80 7.54 .57 7.57 .59 7.60 .62 7.62 .43 7.67 .44 7.69 .45
80_F 27_C .87 .91 .96 .70 .74 .78 .56 .58 .60
85_F 29_C .99 1.00 1.00 .83 .88 .93 .68 .71 .75
Total Cooling Capacity kBtuh 131.2 134.9 138.1 140.0 143.4 146.0 149.4 152.9 155.5
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 38.5 8.33 .74 39.5 8.36 .77 40.5 8.40 .81 41.0 8.41 .58 42.0 8.45 .60 42.8 8.47 .62 43.8 8.50 .43 44.8 8.55 .44 45.6 8.57 .45
80_F 27_C .88 .93 .97 .71 .75 .79 .56 .58 .61
85_F 29_C 1.00 1.00 1.00 .84 .89 .94 .68 .73 .77
Total Cooling Capacity kBtuh kW 127.0 130.5 133.5 135.4 138.6 141.0 144.4 147.7 150.1
37.2 38.2 39.1 39.7 40.6 41.3 42.3 43.3 44.0
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 9.36 .75 9.39 .79 9.43 .83 9.44 .58 9.48 .61 9.50 .63 9.53 .44 9.57 .45 9.60 .46
80_F 27_C .89 .94 .99 .72 .76 .80 .57 .59 .62
85_F 29_C 1.00 1.00 1.00 .86 .91 .96 .70 .74 .78
Total Cooling Capacity kBtuh kW 122.4 125.8 128.8 130.3 133.4 135.6 139.2 142.1 144.4
35.9 36.9 37.7 38.2 39.1 39.7 40.8 41.6 42.3
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 10.54 .76 .91 1.00 10.58 .80 .96 1.00 10.61 .84 1.00 1.00 10.62 .59 .73 .87 10.66 .61 .78 .93 10.68 .64 .82 .98 10.72 .44 .57 .71 10.75 .45 .60 .75 10.78 .46 .63 .80
21 TON HIGH EFFICIENCY − LGA248H2V (R−22/VAV) − COOLING CAPACITY − THREE COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
5040 6300 7560 5040 6300 7560 5040 6300 7560
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2380 2975 3570 2380 2975 3570 2380 2975 3570
197.1 205.0 212.2 208.9 214.3 218.3 222.5 227.5 231.1
57.8 60.1 62.2 61.2 62.8 64.0 65.2 66.7 67.7
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 11.48 .69 11.55 .75 11.62 .83 11.59 .53 11.64 .57 11.68 .60 11.73 .39 11.78 .40 11.82 .42
80_F 27_C .89 .97 1.00 .67 .73 .80 .52 .56 .60
85_F 29_C 1.00 1.00 1.00 .85 .95 .99 .65 .71 .78
Total Cooling Capacity kBtuh 191.5 199.5 206.5 202.7 207.7 211.6 215.7 220.5 223.8
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 56.1 12.83 .70 58.5 12.90 .77 60.5 12.98 .85 59.4 12.93 .54 60.9 12.99 .57 62.0 13.03 .61 63.2 13.07 .39 64.6 13.13 .40 65.6 13.17 .42
80_F 27_C .91 .98 1.00 .68 .74 .82 .52 .57 .60
85_F 29_C 1.00 1.00 1.00 .86 .96 1.00 .66 .72 .80
Total Cooling Capacity kBtuh kW 185.6 193.5 200.3 195.9 200.7 204.5 208.4 212.9 216.1
54.4 56.7 58.7 57.4 58.8 59.9 61.1 62.4 63.3
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 14.41 .71 14.47 .79 14.56 .87 14.52 .54 14.57 .58 14.62 .62 14.65 .39 14.70 .41 14.75 .42
80_F 27_C .93 .99 1.00 .69 .76 .84 .53 .57 .62
85_F 29_C 1.00 1.00 1.00 .89 .97 1.00 .67 .74 .82
Total Cooling Capacity kBtuh kW 179.2 187.2 193.9 188.7 193.3 196.9 200.8 204.9 207.8
52.5 54.9 56.8 55.3 56.7 57.7 58.8 60.1 60.9
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 16.23 .73 .95 1.00 16.32 .81 1.00 1.00 16.38 .89 1.00 1.00 16.34 .55 .71 .91 16.39 .59 .78 .99 16.45 .63 .87 1.00 16.48 .39 .54 .69 16.53 .41 .59 .76 16.57 .43 .63 .84
21 TON HIGH EFFICIENCY − LGA248H2V (R−22/VAV) − COOLING CAPACITY − FOUR COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6720 8400 10080 6720 8400 10080 6720 8400 10080
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760
244.4 254.7 262.3 253.0 258.7 264.1 268.2 272.7 276.0
71.6 74.6 76.9 74.1 75.8 77.4 78.6 79.9 80.9
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 17.92 .71 18.02 .76 18.09 .89 18.00 .53 18.09 .58 18.14 .62 18.17 .37 18.23 .39 18.27 .41
80_F 27_C .98 1.00 1.00 .69 .75 .85 .53 .57 .62
85_F 29_C 1.00 1.00 1.00 .93 1.00 1.00 .68 .74 .82
Total Cooling Capacity kBtuh 236.4 246.4 253.6 243.8 249.3 254.8 258.2 262.3 265.6
Comp Motor kW 75_F kW Input 24_C 69.3 20.18 .72 72.2 20.28 .80 74.3 20.37 .92 71.5 20.28 .54 73.1 20.35 .59 74.7 20.39 .63 75.7 20.44 .37 76.9 20.49 .39 77.8 20.54 .41
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 28
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C 1.00 1.00 1.00 .71 .76 .89 .54 .59 .63
85_F 29_C 1.00 1.00 1.00 .96 1.00 1.00 .69 .75 .86
Total Cooling Capacity kBtuh kW 228.2 237.6 244.5 234.0 239.7 245.3 247.8 251.6 254.7
66.9 69.6 71.7 68.6 70.2 71.9 72.6 73.7 74.6
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 22.77 .73 22.89 .85 22.98 .95 22.87 .55 22.94 .60 23.00 .65 23.04 .38 23.11 .40 23.11 .42
80_F 27_C 1.00 1.00 1.00 .72 .81 .93 .55 .60 .65
85_F 29_C 1.00 1.00 1.00 .99 1.00 1.00 .71 .77 .90
Total Cooling Capacity kBtuh kW 219.5 228.2 234.8 224.0 229.7 235.2 236.9 240.6 243.4
64.3 66.9 68.8 65.6 67.3 68.9 69.4 70.5 71.3
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 25.76 .75 1.00 1.00 25.86 .89 1.00 1.00 25.93 .99 1.00 1.00 25.84 .56 .74 1.00 25.91 .62 .85 1.00 25.93 .66 .97 1.00 26.01 .38 .56 .72 26.07 .41 .61 .82 26.09 .43 .66 .94
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
25 TON STANDARD EFFICIENCY − LGC300S (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
8000 10000 12000 8000 10000 12000 8000 10000 12000
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665
149.0 154.6 159.2 158.0 162.8 166.2 167.8 172.4 175.6
43.7 45.3 46.7 46.3 47.7 48.7 49.2 50.5 51.5
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 8.34 .61 8.46 .66 8.56 .73 8.52 .48 8.64 .50 8.74 .53 8.76 .36 8.88 .37 8.96 .38
80_F 27_C .77 .86 .95 .59 .63 .70 .46 .49 .52
85_F 29_C .94 1.00 1.00 .72 .82 .91 .56 .61 .67
Total Cooling Capacity kBtuh 144.6 150.0 154.4 153.2 157.8 161.0 162.6 167.2 170.0
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 42.4 9.28 .61 44.0 9.42 .67 45.3 9.52 .74 44.9 9.48 .48 46.2 9.60 .51 47.2 9.70 .54 47.7 9.74 .36 49.0 9.84 .37 49.8 9.94 .38
80_F 27_C .78 .88 .96 .59 .64 .71 .47 .50 .53
85_F 29_C .95 1.00 1.00 .74 .84 .93 .57 .62 .69
Total Cooling Capacity kBtuh kW 140.0 145.2 149.6 148.0 152.4 155.6 157.4 161.4 164.2
41.0 42.6 43.8 43.4 44.7 45.6 46.1 47.3 48.1
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 10.38 .62 10.50 .69 10.62 .76 10.58 .49 10.70 .51 10.78 .55 10.82 .36 10.94 .37 11.02 .39
80_F 27_C .80 .90 .98 .60 .66 .73 .47 .50 .54
85_F 29_C .97 1.00 1.00 .75 .86 .95 .58 .63 .71
Total Cooling Capacity kBtuh kW 135.0 140.0 144.6 142.8 146.8 149.8 151.6 155.4 158.2
39.6 41.0 42.4 41.9 43.0 43.9 44.4 45.5 46.4
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 11.62 .63 .82 .99 11.74 .71 .93 1.00 11.88 .78 1.00 1.00 11.82 .49 .61 .78 11.94 .52 .68 .89 12.04 .55 .76 .97 12.08 .37 .48 .59 12.20 .38 .51 .65 12.28 .39 .55 .73
25 TON STANDARD EFFICIENCY − LGC300S (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
8000 10000 12000 8000 10000 12000 8000 10000 12000
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665
291.5 302.4 311.6 308.4 317.4 324.1 327.8 336.3 342.1
85.4 88.6 91.3 90.4 93.0 95.0 96.1 98.6 100.3
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 20.90 .70 21.15 .76 21.38 .82 21.30 .55 21.55 .58 21.71 .61 21.79 .41 22.03 .42 22.20 .43
80_F 27_C .86 .95 1.00 .68 .73 .80 .53 .57 .60
85_F 29_C 1.00 1.00 1.00 .82 .91 .99 .65 .71 .77
Total Cooling Capacity kBtuh 281.1 291.7 301.3 297.4 305.9 312.2 315.9 323.9 329.6
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 82.4 23.41 .71 85.5 23.65 .77 88.3 23.92 .84 87.2 23.81 .55 89.7 24.05 .59 91.5 24.24 .62 92.6 24.33 .41 94.9 24.57 .42 96.6 24.73 .44
80_F 27_C .88 .97 1.00 .69 .75 .82 .54 .58 .61
85_F 29_C 1.00 1.00 1.00 .84 .93 1.00 .66 .73 .79
Total Cooling Capacity kBtuh kW 270.1 280.5 290.1 285.5 293.5 299.4 303.4 311.0 316.0
79.2 82.2 85.0 83.7 86.0 87.7 88.9 91.1 92.6
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 26.23 .72 26.51 .79 26.79 .86 26.67 .56 26.91 .60 27.11 .63 27.23 .41 27.43 .43 27.63 .44
80_F 27_C .90 .99 1.00 .70 .77 .84 .55 .59 .63
85_F 29_C 1.00 1.00 1.00 .86 .96 1.00 .68 .74 .82
Total Cooling Capacity kBtuh kW 258.4 268.5 278.7 272.7 280.2 286.0 290.1 297.0 301.6
75.7 78.7 81.7 79.9 82.1 83.8 85.0 87.0 88.4
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 29.44 .74 .92 1.00 29.74 .81 1.00 1.00 30.05 .89 1.00 1.00 29.89 .57 .71 .88 30.17 .61 .79 .98 30.37 .65 .87 1.00 30.46 .42 .55 .69 30.67 .43 .60 .76 30.87 .45 .64 .84
25 TON HIGH EFFICIENCY − LGC300H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
8000 10000 12000 8000 10000 12000 8000 10000 12000
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665
157.5 163.6 168.5 167.5 173.2 177.2 178.5 184.2 187.9
46.2 47.9 49.4 49.1 50.8 51.9 52.3 54.0 55.1
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 8.00 .58 8.08 .63 8.14 .69 8.12 .46 8.19 .48 8.25 .51 8.27 .35 8.34 .36 8.39 .37
80_F 27_C .73 .83 .91 .56 .60 .66 .44 .47 .49
85_F 29_C .90 .99 1.00 .69 .78 .87 .54 .58 .63
Total Cooling Capacity kBtuh 152.7 158.6 163.4 162.4 167.7 171.5 173.0 178.3 181.8
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 44.8 9.01 .59 46.5 9.11 .64 47.9 9.17 .71 47.6 9.16 .46 49.1 9.25 .49 50.3 9.31 .51 50.7 9.33 .35 52.3 9.41 .36 53.3 9.48 .37
80_F 27_C .75 .85 .93 .57 .61 .67 .45 .47 .50
85_F 29_C .92 1.00 1.00 .70 .80 .89 .55 .59 .65
Total Cooling Capacity kBtuh kW 147.9 153.6 158.4 157.1 162.2 165.8 167.5 172.4 175.7
43.3 45.0 46.4 46.0 47.5 48.6 49.1 50.5 51.5
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 10.09 .60 10.20 .65 10.28 .72 10.26 .47 10.36 .49 10.43 .52 10.45 .35 10.55 .36 10.61 .37
80_F 27_C .77 .87 .95 .57 .62 .69 .45 .48 .51
85_F 29_C .94 1.00 1.00 .72 .82 .91 .55 .60 .66
Total Cooling Capacity kBtuh kW 143.0 148.4 153.1 151.8 156.5 160.0 161.7 166.3 169.5
41.9 43.5 44.9 44.5 45.9 46.9 47.4 48.7 49.7
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 11.28 .60 .79 .96 11.39 .67 .89 1.00 11.49 .74 .97 1.00 11.46 .47 .58 .74 11.57 .50 .64 .85 11.64 .53 .71 .94 11.67 .35 .46 .56 11.77 .36 .49 .61 11.85 .37 .52 .69
25 TON HIGH EFFICIENCY − LGC300H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
8000 10000 12000 8000 10000 12000 8000 10000 12000
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665
294.0 305.2 314.8 312.4 322.4 329.6 332.8 342.6 349.4
86.2 89.4 92.3 91.6 94.5 96.6 97.5 100.4 102.4
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 18.94 .67 19.16 .72 19.30 .78 19.26 .53 19.46 .56 19.58 .59 19.62 .40 19.80 .41 19.94 .42
80_F 27_C .82 .90 .96 .65 .70 .76 .51 .54 .57
85_F 29_C .96 1.00 1.00 .78 .86 .93 .62 .68 .73
Total Cooling Capacity kBtuh 284.2 295.2 304.2 301.8 311.2 318.0 321.4 330.6 337.0
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 83.3 21.18 .68 86.5 21.38 .74 89.2 21.56 .80 88.4 21.52 .53 91.2 21.70 .56 93.2 21.84 .59 94.2 21.90 .40 96.9 22.10 .41 98.8 22.24 .42
80_F 27_C .83 .91 .98 .66 .71 .77 .52 .55 .58
85_F 29_C .97 1.00 1.00 .79 .88 .95 .63 .69 .75
Total Cooling Capacity kBtuh kW 274.0 284.4 293.6 290.6 299.4 305.6 309.4 318.0 323.6
80.3 83.3 86.0 85.2 87.7 89.6 90.7 93.2 94.8
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 23.66 .69 23.88 .75 24.06 .82 24.06 .54 24.22 .57 24.40 .60 24.48 .40 24.66 .41 24.82 .43
80_F 27_C .85 .93 .99 .67 .73 .79 .52 .56 .59
85_F 29_C .99 1.00 1.00 .81 .90 .97 .65 .70 .77
Total Cooling Capacity kBtuh kW 262.6 272.8 282.2 278.4 286.6 292.4 296.4 304.4 309.8
77.0 79.9 82.7 81.6 84.0 85.7 86.9 89.2 90.8
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 26.46 .70 .87 1.00 26.74 .77 .96 1.00 26.98 .84 1.00 1.00 26.88 .55 .68 .83 27.08 .58 .75 .92 27.28 .62 .81 .99 27.34 .40 .53 .66 27.54 .42 .57 .72 27.70 .43 .61 .79
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 29
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
25 TON HIGH EFFICIENCY − LGC300H2V (R−22/VAV) − COOLING CAPACITY − ONE COMPRESSOR OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
2000 2500 3000 2000 2500 3000 2000 2500 3000
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 945 1180 1415 945 1180 1415 945 1180 1415
59.8 64.2 67.4 64.3 68.9 72.2 69.0 73.8 77.2
17.5 18.8 19.8 18.8 20.2 21.2 20.2 21.6 22.6
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.10 .60 5.19 .61 5.25 .63 5.20 .50 5.28 .50 5.34 .51 5.29 .41 5.38 .41 5.44 .40
80_F 27_C .68 .71 .73 .57 .58 .60 .48 .48 .49
Total Cooling Capacity
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 85_F 75_F kBtuh kW Input 29_C 24_C .76 58.2 17.1 5.75 .61 .80 62.4 18.3 5.85 .62 .84 65.4 19.2 5.92 .64 .64 62.6 18.3 5.86 .50 .67 67.0 19.6 5.96 .51 .70 70.1 20.5 6.03 .51 .54 67.2 19.7 5.97 .41 .56 71.8 21.0 6.08 .41 .57 75.0 22.0 6.15 .40
80_F 27_C .69 .71 .74 .57 .59 .61 .48 .48 .49
Total Cooling Capacity
85_F kBtuh kW 29_C .77 56.7 16.6 .81 60.6 17.8 .85 63.4 18.6 .65 60.9 17.8 .67 65.0 19.0 .71 67.9 19.9 .54 65.5 19.2 .56 69.7 20.4 .58 72.7 21.3
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 6.45 .61 6.55 .62 6.63 .64 6.57 .50 6.68 .51 6.76 .51 6.70 .41 6.81 .40 6.89 .40
80_F 27_C .69 .72 .75 .58 .59 .61 .48 .48 .49
Total Cooling Capacity
85_F kBtuh kW 29_C .77 55.0 16.1 .82 58.7 17.2 .86 61.4 18.0 .65 59.1 17.3 .68 63.0 18.5 .71 65.7 19.3 .55 63.5 18.6 .56 67.5 19.8 .58 70.3 20.6
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.22 .61 .70 .78 7.33 .63 .73 .83 7.42 .65 .76 .88 7.35 .50 .58 .66 7.47 .51 .59 .69 7.55 .52 .62 .72 7.49 .41 .48 .55 7.62 .40 .48 .57 7.70 .40 .50 .59
25 TON HIGH EFFICIENCY − LGC300H2V (R−22/VAV) − COOLING CAPACITY − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4000 5000 6000 4000 5000 6000 4000 5000 6000
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 1890 2360 2830 1890 2360 2830 1890 2360 2830
156.1 162.4 167.4 166.8 172.7 177.0 177.9 184.0 188.4
45.7 47.6 49.1 48.9 50.6 51.9 52.1 53.9 55.2
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 9.43 .71 9.54 .75 9.61 .80 9.59 .57 9.70 .59 9.76 .62 9.77 .43 9.87 .44 9.94 .45
80_F 27_C .84 .91 .97 .68 .73 .78 .55 .57 .60
85_F 29_C .97 1.00 1.00 .81 .87 .94 .66 .70 .75
Total Cooling Capacity kBtuh 151.3 157.4 162.0 161.5 167.2 171.2 172.4 178.1 182.2
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 44.3 10.63 .72 46.1 10.74 .77 47.5 10.84 .82 47.3 10.83 .57 49.0 10.95 .60 50.2 11.02 .62 50.5 11.04 .43 52.2 11.15 .44 53.4 11.22 .45
80_F 27_C .85 .92 .98 .69 .74 .79 .55 .58 .61
85_F 29_C .98 1.00 1.00 .82 .89 .95 .66 .71 .76
Total Cooling Capacity kBtuh kW 146.5 152.2 156.8 156.3 161.6 165.3 166.8 172.2 175.9
42.9 44.6 46.0 45.8 47.4 48.4 48.9 50.5 51.6
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 11.92 .73 12.03 .78 12.15 .83 12.13 .57 12.25 .60 12.35 .63 12.36 .44 12.49 .44 12.59 .46
80_F 27_C .87 .94 1.00 .70 .75 .80 .56 .59 .62
85_F 29_C 1.00 1.00 1.00 .83 .90 .97 .67 .72 .78
Total Cooling Capacity kBtuh kW 141.5 147.0 151.4 150.9 155.9 159.4 161.0 166.1 169.4
41.5 43.1 44.4 44.2 45.7 46.7 47.2 48.7 49.6
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 13.32 .74 .88 1.00 13.44 .79 .95 1.00 13.56 .84 1.00 1.00 13.55 .58 .71 .85 13.69 .61 .76 .92 13.78 .64 .82 .99 13.81 .44 .56 .68 13.94 .45 .59 .74 14.04 .46 .63 .80
25 TON HIGH EFFICIENCY − LGC300H2V (R−22/VAV) − COOLING CAPACITY − THREE COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6000 7500 9000 6000 7500 9000 6000 7500 9000
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2830 3540 4250 2830 3540 4250 2830 3540 4250
238.8 247.2 255.4 252.9 259.5 264.2 269.0 275.3 279.8
70.0 72.4 74.9 74.1 76.1 77.4 78.8 80.7 82.0
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 14.71 .69 14.83 .74 14.97 .82 14.93 .53 15.04 .56 15.12 .59 15.19 .39 15.31 .40 15.38 .42
80_F 27_C .88 .97 1.00 .67 .72 .79 .52 .55 .59
85_F 29_C 1.00 1.00 1.00 .83 .93 1.00 .64 .70 .76
Total Cooling Capacity kBtuh 231.3 239.8 247.9 244.9 251.0 255.6 260.5 266.3 270.5
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 67.8 16.58 .70 70.3 16.74 .76 72.7 16.91 .84 71.8 16.85 .54 73.6 16.98 .57 74.9 17.07 .60 76.3 17.15 .39 78.0 17.28 .40 79.3 17.37 .42
80_F 27_C .90 .99 1.00 .68 .73 .81 .52 .56 .60
85_F 29_C 1.00 1.00 1.00 .85 .95 1.00 .65 .71 .78
Total Cooling Capacity kBtuh kW 224.0 232.5 240.4 236.8 242.5 246.9 251.8 257.3 261.0
65.6 68.1 70.5 69.4 71.1 72.4 73.8 75.4 76.5
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 18.58 .71 18.77 .78 18.95 .86 18.88 .54 19.02 .58 19.12 .61 19.23 .39 19.36 .41 19.45 .42
80_F 27_C .92 1.00 1.00 .69 .75 .83 .53 .57 .61
85_F 29_C 1.00 1.00 1.00 .88 .97 1.00 .67 .73 .80
Total Cooling Capacity kBtuh kW 216.5 225.2 232.9 228.5 233.8 238.2 242.8 247.9 251.5
63.4 66.0 68.3 67.0 68.5 69.8 71.2 72.7 73.7
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.76 .72 .94 1.00 20.97 .80 1.00 1.00 21.19 .88 1.00 1.00 21.08 .55 .70 .90 21.23 .59 .77 .99 21.34 .62 .85 1.00 21.47 .40 .54 .68 21.60 .41 .58 .75 21.71 .43 .62 .83
25 TON HIGH EFFICIENCY − LGC300H2V (R−22/VAV) − COOLING CAPACITY − FOUR COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
8000 10000 12000 8000 10000 12000 8000 10000 12000
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665
304.1 316.2 325.9 316.5 323.5 329.3 335.4 341.3 345.2
89.1 92.7 95.5 92.8 94.8 96.5 98.3 100.0 101.2
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 23.84 .70 24.12 .76 24.36 .88 24.13 .53 24.29 .57 24.42 .61 24.57 .37 24.71 .39 24.79 .41
80_F 27_C .97 1.00 1.00 .69 .74 .85 .52 .57 .61
85_F 29_C 1.00 1.00 1.00 .93 1.00 1.00 .67 .73 .81
Total Cooling Capacity kBtuh 294.7 306.4 315.7 305.4 312.1 317.9 323.5 328.8 332.8
Comp Motor kW 75_F kW Input 24_C 86.4 26.66 .71 89.8 26.98 .80 92.5 27.19 .91 89.5 26.94 .54 91.5 27.12 .58 93.2 27.27 .62 94.8 27.41 .38 96.4 27.56 .39 97.5 27.66 .41
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 30
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .99 1.00 1.00 .70 .76 .88 .53 .58 .62
85_F 29_C 1.00 1.00 1.00 .95 1.00 1.00 .68 .74 .85
Total Cooling Capacity kBtuh kW 284.6 296.0 304.7 293.8 300.1 306.4 310.9 316.1 319.6
83.4 86.7 89.3 86.1 88.0 89.8 91.1 92.6 93.7
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 29.78 .73 30.11 .84 30.37 .94 30.07 .55 30.25 .59 30.44 .63 30.58 .38 30.72 .40 30.84 .42
80_F 27_C 1.00 1.00 1.00 .71 .80 .92 .54 .59 .63
85_F 29_C 1.00 1.00 1.00 .98 1.00 1.00 .70 .76 .89
Total Cooling Capacity kBtuh kW 273.8 284.8 292.9 281.3 287.6 294.0 297.5 302.0 305.5
80.2 83.5 85.8 82.4 84.3 86.2 87.2 88.5 89.5
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 33.35 .74 1.00 1.00 33.70 .88 1.00 1.00 33.98 .97 1.00 1.00 33.61 .56 .73 1.00 33.83 .61 .85 1.00 34.00 .65 .95 1.00 34.12 .38 .55 .71 34.31 .41 .60 .81 34.43 .43 .65 .93
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
30 TON HIGH EFFICIENCY − LGA360H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
9000 11200 13400 9000 11200 13400 9000 11200 13400
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 4250 5285 6325 4250 5285 6325 4250 5285 6325
228.1 236.4 242.9 241.8 249.1 254.2 256.8 263.7 268.6
66.8 69.3 71.2 70.9 73.0 74.5 75.3 77.3 78.7
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 11.16 .65 11.32 .70 11.44 .75 11.42 .51 11.56 .54 11.67 .56 11.72 .39 11.87 .40 11.98 .41
80_F 27_C .79 .87 .94 .63 .67 .73 .50 .53 .55
85_F 29_C .93 1.00 1.00 .76 .83 .91 .61 .65 .70
Total Cooling Capacity kBtuh 222.4 230.4 236.8 235.6 242.6 247.6 250.2 257.0 261.6
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 65.2 12.26 .66 67.5 12.42 .71 69.4 12.53 .76 69.0 12.51 .52 71.1 12.65 .54 72.6 12.77 .57 73.3 12.81 .39 75.3 12.95 .40 76.7 13.07 .41
80_F 27_C .80 .88 .95 .63 .68 .74 .50 .53 .56
85_F 29_C .95 1.00 1.00 .77 .85 .92 .61 .66 .72
Total Cooling Capacity kBtuh kW 216.0 223.6 230.0 228.7 235.3 240.1 242.9 249.3 253.7
63.3 65.5 67.4 67.0 69.0 70.4 71.2 73.1 74.4
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 13.51 .66 13.67 .72 13.79 .78 13.76 .52 13.91 .55 14.00 .58 14.06 .39 14.21 .40 14.30 .41
80_F 27_C .82 .90 .97 .64 .69 .75 .51 .54 .57
85_F 29_C .96 1.00 1.00 .78 .86 .94 .62 .67 .73
Total Cooling Capacity kBtuh kW 208.7 216.2 222.6 221.0 227.2 231.9 234.8 240.7 245.0
61.2 63.4 65.2 64.8 66.6 68.0 68.8 70.5 71.8
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 14.96 .67 .83 .98 15.08 .73 .92 1.00 15.21 .79 .98 1.00 15.19 .53 .65 .80 15.34 .56 .71 .88 15.42 .59 .77 .95 15.49 .39 .51 .63 15.63 .40 .54 .68 15.72 .42 .58 .75
30 TON HIGH EFFICIENCY − LGA360H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
9000 11200 13400 9000 11200 13400 9000 11200 13400
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 4250 5285 6325 4250 5285 6325 4250 5285 6325
340.0 352.4 362.6 360.3 370.6 378.2 382.9 392.8 399.7
99.6 103.3 106.3 105.6 108.6 110.8 112.2 115.1 117.1
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 22.02 .71 22.26 .76 22.46 .82 22.41 .55 22.64 .58 22.77 .62 22.87 .42 23.09 .43 23.26 .44
80_F 27_C .85 .92 .98 .68 .74 .79 .54 .57 .61
85_F 29_C .98 1.00 1.00 .82 .89 .96 .66 .72 .77
Total Cooling Capacity kBtuh 328.5 340.4 350.9 347.8 357.7 365.0 369.9 379.2 385.7
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 96.3 24.34 .72 99.8 24.55 .77 102.8 24.76 .83 101.9 24.70 .56 104.8 24.93 .59 107.0 25.07 .63 108.4 25.17 .42 111.1 25.39 .43 113.0 25.53 .44
80_F 27_C .87 .94 .99 .69 .75 .81 .54 .58 .62
85_F 29_C .99 1.00 1.00 .83 .91 .97 .67 .73 .79
Total Cooling Capacity kBtuh kW 315.8 327.5 338.2 334.1 343.6 350.4 355.4 364.2 370.2
92.6 96.0 99.1 97.9 100.7 102.7 104.2 106.7 108.5
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 26.98 .73 27.17 .79 27.40 .85 27.34 .57 27.53 .60 27.69 .64 27.81 .42 27.98 .43 28.13 .45
80_F 27_C .88 .96 1.00 .71 .77 .83 .55 .59 .63
85_F 29_C 1.00 1.00 1.00 .85 .93 .99 .68 .75 .81
Total Cooling Capacity kBtuh kW 302.2 313.6 324.6 319.5 328.2 334.4 339.6 347.9 353.0
88.6 91.9 95.1 93.6 96.2 98.0 99.5 102.0 103.5
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 29.91 .74 .90 1.00 30.17 .81 .98 1.00 30.41 .87 1.00 1.00 30.31 .58 .72 .87 30.49 .61 .79 .95 30.68 .65 .85 1.00 30.78 .42 .56 .70 30.96 .44 .60 .76 31.13 .45 .64 .83
30 TON HIGH EFFICIENCY − LGA360H (R−410A/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
9600 12000 14400 9600 12000 14400 9600 12000 14400
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 4530 5665 6795 4530 5665 6795 4530 5665 6795
263.3 272.8 280.2 278.8 287.4 293.5 295.4 304.0 310.0
77.2 79.9 82.1 81.7 84.2 86.0 86.6 89.1 90.9
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 14.58 .60 14.72 .64 14.85 .70 14.81 .48 14.95 .50 15.05 .52 15.07 .36 15.21 .37 15.30 .38
80_F 27_C .74 .82 .90 .58 .62 .67 .46 .48 .51
85_F 29_C .89 .98 1.00 .70 .78 .86 .55 .60 .64
Total Cooling Capacity kBtuh 254.3 263.7 270.8 269.5 277.7 283.5 285.8 294.0 299.6
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 74.5 16.10 .61 77.3 16.28 .65 79.4 16.41 .71 79.0 16.36 .48 81.4 16.52 .50 83.1 16.63 .53 83.8 16.67 .37 86.2 16.83 .37 87.8 16.93 .38
80_F 27_C .76 .84 .92 .58 .62 .69 .46 .49 .52
85_F 29_C .91 .99 1.00 .71 .80 .88 .56 .61 .66
Total Cooling Capacity kBtuh kW 244.3 253.1 260.3 258.8 266.5 272.0 274.7 282.3 287.4
71.6 74.2 76.3 75.8 78.1 79.7 80.5 82.7 84.2
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 18.00 .61 18.18 .67 18.33 .73 18.28 .48 18.46 .51 18.59 .53 18.63 .37 18.80 .37 18.92 .38
80_F 27_C .78 .86 .94 .59 .64 .71 .47 .50 .52
85_F 29_C .93 1.00 1.00 .73 .82 .91 .57 .62 .68
Total Cooling Capacity kBtuh kW 233.0 241.5 248.6 246.7 253.9 259.1 262.1 269.0 273.7
68.3 70.8 72.9 72.3 74.4 75.9 76.8 78.8 80.2
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.28 .62 .80 .96 20.49 .69 .89 1.00 20.63 .76 .97 1.00 20.58 .49 .60 .76 20.77 .52 .66 .85 20.91 .54 .73 .93 20.95 .37 .48 .58 21.13 .38 .51 .64 21.27 .39 .54 .71
30 TON HIGH EFFICIENCY − LGA360H (R−410A/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
9600 12000 14400 9600 12000 14400 9600 12000 14400
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 4530 5665 6795 4530 5665 6795 4530 5665 6795
371.1 384.2 395.4 392.9 404.3 412.4 417.0 428.0 435.7
108.8 112.6 115.9 115.1 118.5 120.9 122.2 125.4 127.7
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 25.91 .68 26.20 .73 26.36 .78 26.30 .53 26.54 .56 26.74 .59 26.80 .40 27.04 .41 27.19 .42
80_F 27_C .82 .90 .96 .65 .71 .76 .52 .55 .58
85_F 29_C .96 1.00 1.00 .78 .86 .94 .63 .69 .74
Total Cooling Capacity kBtuh 352.8 365.4 376.6 373.2 383.7 391.7 396.3 406.2 413.3
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 103.4 29.18 .69 107.1 29.46 .75 110.4 29.68 .81 109.4 29.59 .54 112.5 29.86 .57 114.8 30.03 .60 116.1 30.12 .40 119.0 30.39 .42 121.1 30.54 .43
80_F 27_C .84 .92 .98 .67 .72 .79 .53 .56 .60
85_F 29_C .98 1.00 1.00 .81 .89 .96 .65 .70 .76
Total Cooling Capacity kBtuh kW 332.4 345.0 355.9 351.3 361.3 368.3 373.2 382.2 388.7
97.4 101.1 104.3 103.0 105.9 107.9 109.4 112.0 113.9
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 33.00 .71 33.22 .77 33.52 .84 33.45 .55 33.64 .59 33.81 .62 33.98 .41 34.22 .42 34.35 .44
80_F 27_C .87 .95 1.00 .69 .75 .82 .54 .57 .61
85_F 29_C 1.00 1.00 1.00 .84 .92 .99 .67 .73 .80
Total Cooling Capacity kBtuh kW 310.2 322.0 333.8 327.2 336.0 342.3 347.4 355.7 360.7
90.9 94.4 97.8 95.9 98.5 100.3 101.8 104.2 105.7
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 37.29 .73 .91 1.00 37.56 .81 .99 1.00 37.86 .88 1.00 1.00 37.71 .56 .71 .87 37.94 .60 .78 .96 38.15 .64 .86 1.00 38.27 .41 .55 .69 38.48 .43 .59 .76 38.63 .44 .64 .83
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 31
COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
30 TON HIGH EFFICIENCY − LGA360H2V (R−22/VAV) − COOLING CAPACITY − ONE COMPRESSOR OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
2250 2800 3350 2250 2800 3350 2250 2800 3350
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 1060 1320 1580 1060 1320 1580 1060 1320 1580
67.5 72.2 75.5 72.5 77.4 80.8 77.9 82.8 86.4
19.8 21.2 22.1 21.2 22.7 23.7 22.8 24.3 25.3
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 5.73 .67 5.86 .68 5.96 .70 5.87 .56 6.01 .56 6.12 .57 6.03 .46 6.18 .45 6.29 .45
80_F 27_C .76 .78 .81 .64 .65 .67 .53 .54 .54
Total Cooling Capacity
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 85_F 75_F kBtuh kW Input 29_C 24_C .84 65.8 19.3 6.40 .67 .88 70.2 20.6 6.52 .69 .92 73.3 21.5 6.62 .71 .72 70.6 20.7 6.54 .56 .74 75.2 22.0 6.68 .56 .77 78.4 23.0 6.78 .57 .61 75.8 22.2 6.70 .46 .62 80.5 23.6 6.85 .45 .64 83.8 24.6 6.95 .45
80_F 27_C .76 .79 .82 .64 .66 .68 .53 .54 .55
Total Cooling Capacity
85_F kBtuh kW 29_C .85 63.8 18.7 .89 68.0 19.9 .93 70.9 20.8 .72 68.6 20.1 .75 72.9 21.4 .78 75.9 22.2 .61 73.6 21.6 .63 78.0 22.9 .65 81.1 23.8
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 7.16 .68 7.28 .69 7.37 .71 7.31 .56 7.43 .57 7.53 .57 7.47 .45 7.61 .45 7.71 .45
80_F 27_C .77 .80 .83 .64 .66 .68 .53 .54 .55
Total Cooling Capacity
85_F kBtuh kW 29_C .85 61.9 18.1 .90 65.7 19.3 .94 68.4 20.0 .73 66.4 19.5 .76 70.4 20.6 .79 73.2 21.5 .61 71.3 20.9 .63 75.4 22.1 .65 78.3 22.9
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.02 .68 .77 .86 8.14 .70 .80 .91 8.24 .72 .84 .96 8.17 .56 .65 .73 8.31 .57 .67 .77 8.40 .58 .69 .81 8.34 .45 .53 .61 8.49 .45 .54 .64 8.59 .45 .55 .66
30 TON HIGH EFFICIENCY − LGA360H2V (R−22/VAV) − COOLING CAPACITY − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4500 5400 6300 4500 5400 6300 4500 5400 6300
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2125 2550 2975 2125 2550 2975 2125 2550 2975
174.1 179.7 184.2 185.7 191.0 194.9 197.9 203.3 207.2
51.0 52.7 54.0 54.4 56.0 57.1 58.0 59.6 60.7
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 10.78 .71 10.93 .74 11.03 .78 11.08 .56 11.21 .58 11.32 .60 11.40 .43 11.54 .43 11.65 .44
80_F 27_C .84 .89 .94 .68 .72 .75 .54 .56 .58
85_F 29_C .96 1.00 1.00 .80 .86 .91 .65 .69 .73
Total Cooling Capacity kBtuh 168.8 174.0 178.5 179.9 184.8 188.5 191.8 196.7 200.3
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 49.5 11.95 .71 51.0 12.09 .75 52.3 12.20 .79 52.7 12.23 .56 54.2 12.38 .58 55.2 12.47 .61 56.2 12.55 .43 57.6 12.70 .43 58.7 12.80 .44
80_F 27_C .85 .91 .96 .69 .73 .77 .54 .57 .59
85_F 29_C .98 1.00 1.00 .82 .87 .93 .66 .70 .74
Total Cooling Capacity kBtuh kW 163.1 168.2 172.3 173.8 178.3 181.8 185.1 189.8 193.3
47.8 49.3 50.5 50.9 52.3 53.3 54.2 55.6 56.7
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 13.28 .72 13.42 .76 13.54 .81 13.57 .57 13.70 .59 13.81 .61 13.90 .43 14.06 .44 14.14 .45
80_F 27_C .87 .92 .98 .70 .74 .78 .55 .58 .60
85_F 29_C .99 1.00 1.00 .83 .89 .95 .67 .71 .76
Total Cooling Capacity kBtuh kW 157.1 162.0 166.0 167.3 171.6 174.8 178.2 182.6 185.7
46.0 47.5 48.6 49.0 50.3 51.2 52.2 53.5 54.4
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 14.81 .73 .88 1.00 14.94 .78 .94 1.00 15.08 .82 .99 1.00 15.12 .57 .71 .85 15.24 .60 .75 .91 15.36 .62 .80 .96 15.47 .43 .56 .68 15.59 .44 .58 .73 15.71 .45 .61 .77
30 TON HIGH EFFICIENCY − LGA360H2V (R−22/VAV) − COOLING CAPACITY − THREE COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6750 8400 10050 6750 8400 10050 6750 8400 10050
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3185 3965 4745 3185 3965 4745 3185 3965 4745
258.7 267.6 276.2 273.3 279.9 284.8 290.3 296.7 301.0
75.8 78.4 80.9 80.1 82.0 83.5 85.1 87.0 88.2
75_F (24_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 16.85 .69 17.10 .74 17.34 .82 17.27 .53 17.46 .56 17.60 .59 17.74 .39 17.94 .40 18.06 .41
80_F 27_C .88 .97 1.00 .67 .72 .79 .52 .55 .59
85_F 29_C 1.00 1.00 1.00 .84 .94 .99 .65 .70 .76
Total Cooling Capacity kBtuh 250.6 259.7 268.2 264.7 270.8 275.4 281.0 287.0 291.1
85_F (29_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW 75_F kW Input 24_C 73.4 18.68 .70 76.1 18.92 .76 78.6 19.16 .84 77.6 19.06 .54 79.4 19.24 .57 80.7 19.39 .60 82.4 19.54 .39 84.1 19.73 .40 85.3 19.85 .42
80_F 27_C .90 .98 1.00 .68 .73 .81 .52 .56 .60
85_F 29_C 1.00 1.00 1.00 .86 .96 1.00 .66 .72 .78
Total Cooling Capacity kBtuh kW 242.4 251.6 259.7 255.5 261.4 265.7 271.3 276.6 280.6
71.0 73.7 76.1 74.9 76.6 77.9 79.5 81.1 82.2
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 20.76 .71 21.02 .78 21.27 .86 21.15 .54 21.33 .58 21.48 .61 21.64 .39 21.81 .41 21.94 .42
80_F 27_C .93 .99 1.00 .69 .75 .83 .53 .57 .61
85_F 29_C 1.00 1.00 1.00 .88 .97 1.00 .67 .73 .81
Total Cooling Capacity kBtuh kW 233.7 243.1 251.0 245.8 251.3 255.8 261.0 266.0 269.5
68.5 71.2 73.6 72.0 73.6 75.0 76.5 78.0 79.0
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 23.15 .72 .95 1.00 23.44 .81 1.00 1.00 23.69 .88 1.00 1.00 23.54 .55 .70 .91 23.72 .59 .78 .99 23.86 .63 .86 1.00 24.05 .39 .54 .68 24.22 .41 .58 .75 24.34 .43 .62 .84
30 TON HIGH EFFICIENCY − LGA360H2V (R−22/VAV) − COOLING CAPACITY − FOUR COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Ai Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
9000 11200 13400 9000 11200 13400 9000 11200 13400
85_F (29_C) Total Cooling Capacity
L/s kBtuh kW 4250 5285 6325 4250 5285 6325 4250 5285 6325
343.5 356.5 366.8 356.2 363.7 370.1 377.2 383.1 387.1
100.7 104.5 107.5 104.4 106.6 108.5 110.5 112.3 113.4
95_F (35_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 27.98 .70 28.36 .75 28.67 .88 28.35 .53 28.56 .57 28.76 .60 28.96 .37 29.15 .39 29.29 .40
80_F 27_C .97 1.00 1.00 .68 .74 .84 .52 .56 .60
85_F 29_C 1.00 1.00 1.00 .93 1.00 1.00 .67 .73 .81
Total Cooling Capacity kBtuh 331.9 344.5 354.5 342.7 350.1 356.6 362.7 368.2 372.3
Comp Motor kW 75_F kW Input 24_C 97.3 31.20 .71 101.0 31.61 .79 103.9 31.90 .91 100.4 31.55 .53 102.6 31.77 .58 104.5 31.99 .62 106.3 32.18 .37 107.9 32.37 .39 109.1 32.51 .41
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 32
105_F (41_C)
Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .99 1.00 1.00 .70 .75 .88 .53 .57 .62
85_F 29_C 1.00 1.00 1.00 .96 1.00 1.00 .68 .74 .85
Total Cooling Capacity kBtuh kW 319.7 331.9 341.1 328.8 335.7 342.7 347.6 352.6 356.4
93.7 97.3 100.0 96.4 98.4 100.4 101.9 103.3 104.5
115_F (46_C)
Sensible To Total Ratio (S/T) Dry Bulb
Comp Motor kW Input 75_F 24_C 34.92 .72 35.32 .84 35.63 .94 35.21 .55 35.49 .59 35.71 .63 35.89 .38 36.07 .40 36.23 .41
80_F 27_C 1.00 1.00 1.00 .71 .80 .92 .54 .59 .63
85_F 29_C 1.00 1.00 1.00 .98 1.00 1.00 .70 .76 .89
Total Cooling Capacity kBtuh kW 307.0 318.6 327.0 314.0 320.8 327.8 331.5 336.3 339.8
90.0 93.4 95.8 92.0 94.0 96.1 97.2 98.6 99.6
Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 39.18 .74 1.00 1.00 39.59 .88 1.00 1.00 39.93 .98 1.00 1.00 39.42 .56 .73 1.00 39.74 .60 .85 1.00 39.99 .65 .95 1.00 40.10 .38 .55 .71 40.31 .40 .60 .82 40.47 .42 .65 .93
HUMIDITROL® REHEAT OPTION RATINGS
13 TON HIGH EFFICIENCY − LGC156H − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
63F (17C) 67F (19C) 71F (22C)
Total Air Volume
65_F (18_C) Total Cooling Capacity
cfm
L/s kBtuh kW
4200 5200 6200 4200 5200 6200 4200 5200 6200
1980 57.6 16.9 2455 62.2 18.2 2925 65.9 19.3 1980 79.2 23.2 2455 83.3 24.4 2925 86.4 25.3 1980 104.4 30.6 2455 108.7 31.8 2925 111.7 32.7
75_F (24_C)
Sensible To Total Ratio (S/T)
85_F (29_C)
Sensible To Total Ratio (S/T)
95_F (35_C)
Sensible To Total Ratio (S/T)
Sensible To Total Total Total Total Ratio (S/T) Comp Comp Comp Comp Cooling Cooling Cooling Motor Capacity Motor Capacity Motor Capacity Motor Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW kW kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW kBtuh kW kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 4.73 0.34 0.62 0.89 50.8 14.9 5.35 0.27 0.60 0.92 44.6 13.1 6.04 0.22 0.60 0.93 36.1 10.6 6.67 0.09 0.55 0.97 4.76 0.45 0.77 1.00 55.2 16.2 5.37 0.42 0.79 1.00 48.8 14.3 6.05 0.38 0.79 1.00 39.9 11.7 6.70 0.32 0.82 1.00 4.78 0.55 0.90 1.00 58.7 17.2 5.39 0.55 0.92 1.00 52.2 15.3 6.07 0.53 0.96 1.00 43.5 12.7 6.72 0.50 0.98 1.00 4.77 0.29 0.44 0.63 72.0 21.1 5.38 0.25 0.42 0.63 65.4 19.1 6.07 0.20 0.40 0.63 57.5 16.8 6.71 0.14 0.36 0.63 4.80 0.34 0.52 0.75 76.0 22.3 5.40 0.30 0.51 0.76 69.1 20.2 6.09 0.27 0.49 0.78 61.0 17.9 6.73 0.22 0.48 0.81 4.81 0.37 0.60 0.87 78.8 23.1 5.42 0.35 0.60 0.88 71.8 21.0 6.11 0.32 0.61 0.91 63.5 18.6 6.75 0.28 0.61 0.95 4.81 0.28 0.40 0.52 95.9 28.1 5.42 0.24 0.37 0.50 88.1 25.8 6.11 0.20 0.34 0.48 78.8 23.1 6.75 0.14 0.30 0.46 4.84 0.29 0.43 0.57 99.9 29.3 5.44 0.26 0.41 0.56 91.8 26.9 6.12 0.22 0.38 0.55 82.3 24.1 6.76 0.17 0.35 0.55 4.86 0.31 0.47 0.63 102.7 30.1 5.46 0.27 0.45 0.64 94.4 27.6 6.14 0.23 0.43 0.64 84.7 24.8 6.78 0.19 0.40 0.64
13 TON HIGH EFFICIENCY − LGC156H − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4200 5200 6200 4200 6200 6200 4200 5200 6200
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 1980 2455 2925 1980 2455 2925 1980 2455 2925
111.5 118.4 123.9 136.9 143.1 147.7 166.3 172.7 177.2
32.6 34.7 36.3 40.1 41.9 43.2 48.7 50.6 51.9
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.08 0.53 0.73 0.93 7.12 0.61 0.85 1.00 7.16 0.68 0.94 1.00 7.14 0.41 0.55 0.71 7.19 0.44 0.62 0.81 7.20 0.48 0.68 0.90 7.20 0.34 0.46 0.58 7.25 0.35 0.49 0.63 7.28 0.36 0.53 0.69
75_F (24_C) Total Cooling Capacity kBtuh kW 103.3 109.8 115.2 128.1 134.0 138.3 156.0 162.0 166.2
30.2 32.2 33.7 37.5 39.2 40.5 45.7 47.4 48.7
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.01 0.50 0.73 0.95 8.04 0.60 0.87 1.00 8.07 0.70 0.96 1.00 8.06 0.39 0.55 0.71 8.09 0.44 0.61 0.82 8.12 0.48 0.69 0.92 8.12 0.32 0.44 0.57 8.15 0.33 0.48 0.64 8.18 0.34 0.51 0.69
85_F (29_C) Total Cooling Capacity kBtuh kW 95.4 101.7 106.9 119.7 125.2 129.2 146.2 151.8 155.6
27.9 29.8 31.3 35.0 36.7 37.8 42.8 44.4 45.6
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.04 0.50 0.75 0.97 9.06 0.60 0.88 1.00 9.09 0.70 0.98 1.00 9.09 0.37 0.54 0.72 9.12 0.42 0.62 0.84 9.14 0.46 0.70 0.95 9.15 0.29 0.43 0.56 9.17 0.31 0.47 0.64 9.19 0.32 0.51 0.70
95_F (35_C) Total Cooling Capacity kBtuh kW 85.1 90.9 96.3 109.8 115.0 118.7 134.8 140.0 143.6
24.9 26.6 28.2 32.2 33.7 34.8 39.5 41.0 42.0
Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 10.05 0.47 0.74 1.00 10.09 0.58 0.90 1.00 10.12 0.71 1.00 1.00 10.11 0.35 0.53 0.73 10.14 0.40 0.61 0.86 10.17 0.45 0.71 0.97 10.17 0.26 0.41 0.56 10.19 0.28 0.46 0.63 10.21 0.31 0.50 0.71
15 TON HIGH EFFICIENCY − LGC180H − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4800 6000 7200 4800 6000 7200 4800 6000 7200
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400
66.6 71.8 75.8 92.2 96.9 100.2 119.4 124.1 127.4
19.5 21.0 22.2 27.0 28.4 29.4 35.0 36.4 37.3
Sensible To Total Ratio (S/T)
75_F (24_C) Total Cooling Capacity
Sensible To Total Ratio (S/T)
Comp Comp Motor Motor Dry Bulb Dry Bulb kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 5.91 0.34 0.61 0.86 58.0 17.0 6.63 0.27 0.59 0.89 5.95 0.44 0.76 1.00 62.9 18.4 6.67 0.40 0.75 1.00 5.99 0.55 0.89 1.00 66.9 19.6 6.70 0.54 0.90 1.00 5.97 0.29 0.45 0.64 82.2 24.1 6.69 0.22 0.42 0.63 6.01 0.33 0.53 0.75 86.6 25.4 6.73 0.28 0.51 0.76 6.05 0.38 0.61 0.86 89.9 26.3 6.76 0.34 0.59 0.87 6.05 0.26 0.39 0.52 110.1 32.3 6.77 0.23 0.37 0.51 6.09 0.27 0.43 0.57 114.6 33.6 6.82 0.23 0.40 0.57 6.12 0.28 0.47 0.64 117.7 34.5 6.84 0.25 0.44 0.64
85_F (29_C) Total Cooling Capacity kBtuh kW 45.1 49.9 53.7 74.9 79.1 82.2 102.7 106.9 109.8
13.2 14.6 15.7 22.0 23.2 24.1 30.1 31.3 32.2
Sensible To Total Ratio (S/T)
95_F (35_C)
Sensible To Total Ratio (S/T) Comp Comp Motor Motor Dry Bulb Dry Bulb kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 7.42 0.11 0.52 0.89 39.0 11.4 8.14 0.04 0.52 0.94 7.44 0.32 0.75 1.00 43.6 12.8 8.18 0.27 0.78 1.00 7.48 0.47 0.93 1.00 47.4 13.9 8.21 0.47 0.95 1.00 7.48 0.19 0.40 0.62 66.5 19.5 8.21 0.12 0.36 0.63 7.52 0.24 0.50 0.76 70.5 20.7 8.24 0.20 0.47 0.78 7.54 0.30 0.60 0.88 73.4 21.5 8.28 0.27 0.59 0.91 7.56 0.20 0.34 0.49 91.9 26.9 8.29 0.13 0.31 0.46 7.60 0.22 0.39 0.56 95.9 28.1 8.32 0.16 0.36 0.56 7.62 0.24 0.43 0.64 98.6 28.9 8.35 0.18 0.41 0.65 Total Cooling Capacity
15 TON HIGH EFFICIENCY − LGC180H − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
4800 6000 7200 4800 6000 7200 4800 6000 7200
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400
126.3 133.9 139.8 155.9 162.7 167.6 187.3 194.3 199.2
37.01 39.2 41.0 45.7 47.7 49.1 54.9 56.9 58.4
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.87 0.51 0.70 0.90 8.93 0.58 0.81 1.00 8.98 0.65 0.91 1.00 8.96 0.39 0.54 0.70 9.02 0.43 0.60 0.80 9.08 0.47 0.67 0.89 9.08 0.31 0.44 0.57 9.14 0.33 0.48 0.61 9.19 0.34 0.51 0.67
75_F (24_C) Total Cooling Capacity kBtuh kW 116.0 123.3 129.2 144.2 150.6 155.3 176.2 182.8 187.3
34.0 36.1 37.9 42.3 44.1 45.5 51.6 53.6 54.9
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.95 0.50 0.70 0.92 10.01 0.57 0.83 1.00 10.05 0.67 0.92 1.00 10.04 0.36 0.53 0.70 10.10 0.41 0.60 0.80 10.15 0.46 0.67 0.89 10.16 0.29 0.43 0.56 10.23 0.31 0.46 0.61 10.27 0.32 0.50 0.68
85_F (29_C) Total Cooling Capacity kBtuh kW 101.3 108.3 113.9 134.8 141.0 145.4 166.6 172.7 177.0
29.7 31.7 33.4 39.5 41.3 42.6 48.8 50.6 51.9
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 11.16 0.44 0.70 0.93 11.20 0.54 0.83 1.00 11.26 0.65 0.95 1.00 11.25 0.36 0.52 0.71 11.31 0.39 0.60 0.82 11.35 0.44 0.67 0.92 11.37 0.27 0.42 0.55 11.44 0.29 0.46 0.63 11.47 0.32 0.50 0.69
95_F (35_C) Total Cooling Capacity kBtuh kW 93.3 100.0 105.6 124.3 130.1 134.4 153.6 159.4 163.4
27.3 29.3 30.9 36.4 38.1 39.4 45.0 46.7 47.9
Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 12.36 0.43 0.71 0.96 12.42 0.56 0.86 1.00 12.47 0.67 0.97 1.00 12.47 0.33 0.52 0.71 12.52 0.38 0.60 0.83 12.58 0.43 0.69 0.93 12.59 0.25 0.39 0.54 12.64 0.27 0.45 0.62 12.69 0.29 0.49 0.70
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 33
HUMIDITROL® REHEAT OPTION RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
17.5 TON HIGH EFFICIENCY − LGC210H − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
63F (17C) 67F (19C) 71F (22C)
Total Air Volume
65_F (18_C) Total Cooling Capacity
cfm
L/s kBtuh kW
5600 7000 8400 5600 7000 8400 5600 7000 8400
2645 45.2 13.2 3305 50.0 14.6 3965 53.6 15.7 2645 68.6 20.1 3305 72.8 21.3 3965 75.8 22.2 2645 97.8 28.6 3305 102.0 29.9 3965 104.8 30.7
Sensible To Total Ratio (S/T)
75_F (24_C) Sensible To Total Ratio (S/T)
85_F (29_C) Total Cooling Capacity
Sensible To Total Ratio (S/T)
95_F (35_C)
Sensible To Total Ratio (S/T) Comp Comp Comp Comp Motor Motor Motor Motor Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW kW kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW kBtuh kW kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 4.94 0.15 0.52 0.90 40.2 11.8 5.37 0.10 0.52 0.95 32.6 9.5 5.84 −0.04 0.50 1.00 23.8 6.7 6.51 −0.33 0.42 1.00 4.98 0.32 0.77 1.00 44.6 13.1 5.39 0.28 0.78 1.00 36.8 10.8 5.88 0.22 0.83 1.00 27.8 8.1 6.54 0.08 0.85 1.00 5.00 0.50 0.93 1.00 48.2 14.1 5.43 0.50 0.98 1.00 40.6 11.9 5.90 0.46 1.00 1.00 32.0 9.4 6.56 0.43 1.00 1.00 5.00 0.17 0.35 0.59 63.2 18.5 5.41 0.12 0.34 0.61 55.4 16.2 5.90 0.05 0.29 0.59 46.2 13.5 6.56 −0.09 0.20 0.57 5.02 0.24 0.47 0.75 67.0 19.6 5.45 0.20 0.46 0.77 59.0 17.3 5.94 0.14 0.43 0.81 49.6 14.5 6.60 0.04 0.39 0.82 5.06 0.30 0.58 0.90 69.8 20.4 5.47 0.28 0.59 0.93 61.6 18.0 5.96 0.21 0.59 0.96 52.0 15.2 6.62 0.12 0.57 1.00 5.06 0.21 0.35 0.49 92.0 26.9 5.49 0.18 0.34 0.49 83.8 24.5 5.96 0.15 0.30 0.47 74.4 21.8 6.62 0.08 0.26 0.44 5.10 0.23 0.39 0.56 95.8 28.1 5.51 0.21 0.39 0.56 87.4 25.6 6.00 0.17 0.37 0.56 77.6 22.7 6.66 0.11 0.33 0.54 5.12 0.25 0.45 0.64 98.4 28.8 5.55 0.24 0.44 0.65 89.8 26.3 6.01 0.19 0.41 0.66 79.8 23.4 6.67 0.13 0.39 0.66 Total Cooling Capacity
Total Cooling Capacity
17.5 TON HIGH EFFICIENCY − LGC210H − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
5600 7000 8400 5600 7000 8400 5600 7000 8400
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965
155.4 164.8 172.2 186.2 194.6 200.6 223.6 232.0 237.6
45.5 48.3 50.4 54.5 57.0 58.7 65.5 67.9 69.6
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 10.02 0.52 0.73 0.94 10.08 0.61 0.86 1.00 10.14 0.70 0.97 1.00 10.12 0.40 0.55 0.71 10.18 0.44 0.61 0.83 10.26 0.48 0.69 0.93 10.26 0.32 0.45 0.57 10.34 0.33 0.49 0.63 10.38 0.34 0.52 0.70
75_F (24_C) Total Cooling Capacity kBtuh kW 147.2 156.0 163.4 177.2 185.0 190.6 214.0 221.6 226.8
43.1 45.7 47.8 51.9 54.2 55.8 62.7 64.9 66.4
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 11.09 0.52 0.75 0.97 11.15 0.62 0.89 1.00 11.21 0.72 0.99 1.00 11.91 0.40 0.55 0.73 11.27 0.44 0.62 0.85 11.31 0.48 0.71 0.95 11.35 0.31 0.44 0.58 11.39 0.32 0.48 0.64 11.45 0.35 0.53 0.71
85_F (29_C) Total Cooling Capacity kBtuh kW 136.1 144.5 152.1 165.7 172.8 178.1 201.6 208.8 213.6
39.9 42.3 44.5 48.5 50.6 52.1 59.0 61.1 62.5
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 12.29 0.52 0.76 1.00 12.36 0.61 0.91 1.00 12.42 0.72 1.00 1.00 12.40 0.38 0.55 0.73 12.50 0.42 0.63 0.87 12.54 0.48 0.71 0.97 12.54 0.30 0.44 0.58 12.62 0.32 0.48 0.64 12.65 0.33 0.53 0.72
95_F (35_C) Total Cooling Capacity kBtuh kW 123.4 131.5 139.8 152.2 159.0 163.9 187.7 194.2 198.5
36.1 38.5 40.9 44.6 46.6 48.0 55.0 56.9 58.1
Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 13.79 0.50 0.77 1.00 13.87 0.62 0.94 1.00 13.90 0.74 1.00 1.00 13.90 0.36 0.54 0.75 13.98 0.41 0.63 0.89 14.02 0.47 0.74 1.00 14.02 0.28 0.42 0.58 14.10 0.29 0.47 0.65 14.13 0.32 0.52 0.74
20 TON HIGH EFFICIENCY − LGA240H − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
63F (17C) 67F (19C) 71F (22C)
Total Air Volume
65_F (18_C) Total Cooling Capacity
cfm
L/s kBtuh kW
6400 8000 9600 6400 8000 9600 6400 8000 9600
3020 51.6 15.1 3775 56.6 16.6 4530 60.8 17.8 3020 78.6 23.0 3775 83.2 24.4 4530 86.4 25.3 3020 106.6 31.2 3775 111.0 32.5 4530 114.2 33.5
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 6.08 0.09 0.46 0.85 6.14 0.26 0.70 1.00 6.18 0.42 0.89 1.00 6.16 0.14 0.33 0.55 6.22 0.20 0.41 0.72 6.24 0.26 0.54 0.85 6.26 0.16 0.30 0.45 6.30 0.19 0.35 0.51 6.34 0.21 0.39 0.59
75_F (24_C) Total Cooling Capacity kBtuh kW 41.8 46.8 50.8 69.6 73.8 77.0 101.4 105.4 108.4
12.3 13.7 14.9 20.4 21.6 22.6 29.7 30.9 31.8
85_F (29_C)
Sensible To Total Ratio (S/T)
95_F (35_C)
Sensible To Total Ratio (S/T)
Sensible To Total Total Total Ratio (S/T) Comp Comp Comp Cooling Cooling Motor Capacity Motor Capacity Motor Dry Bulb Dry Bulb Dry Bulb kW kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 6.72 −0.06 0.41 0.85 30.8 9.0 7.37 −0.35 0.27 0.88 19.8 5.8 8.13 −0.97 0.01 0.94 6.75 0.15 0.70 1.00 35.6 10.4 7.43 −0.01 0.69 1.00 24.2 7.1 8.19 −0.33 0.66 1.00 6.81 0.38 0.92 1.00 39.6 11.6 7.46 0.29 0.94 1.00 28.4 8.3 8.24 0.13 1.00 1.00 6.79 0.06 0.29 0.53 58.4 17.1 7.44 −0.06 0.18 0.50 46.8 13.7 8.22 −0.28 0.04 0.45 6.85 0.14 0.40 0.73 62.4 18.3 7.50 0.04 0.33 0.73 50.6 14.9 8.27 −0.14 0.26 0.73 6.87 0.21 0.52 0.87 65.4 19.2 7.54 0.12 0.49 0.90 53.4 15.7 8.32 −0.01 0.45 0.93 6.89 0.15 0.30 0.44 91.8 26.9 7.56 0.09 0.25 0.41 84.8 24.8 8.33 0.05 0.23 0.40 6.95 0.17 0.35 0.51 95.6 28.0 7.59 0.12 0.30 0.51 88.6 26.0 8.37 0.08 0.29 0.50 6.96 0.19 0.39 0.59 98.4 28.8 7.65 0.14 0.37 0.60 91.0 26.7 8.41 0.12 0.36 0.61
20 TON HIGH EFFICIENCY − LGA240H − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
6400 8000 9600 6400 8000 9600 6400 8000 9600
65_F (18_C) Total Cooling Capacity
L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530
178.9 189.0 197.4 214.0 223.2 230.0 251.3 260.2 266.3
52.4 55.4 57.9 62.7 65.4 67.4 73.6 76.3 78.0
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 12.22 0.55 0.74 0.94 12.34 0.62 0.86 1.00 12.42 0.71 0.96 1.00 12.40 0.42 0.57 0.72 12.50 0.45 0.64 0.82 12.57 0.49 0.70 0.93 12.58 0.32 0.45 0.58 12.68 0.33 0.49 0.63 12.78 0.35 0.52 0.70
75_F (24_C) Total Cooling Capacity kBtuh kW 165.6 175.4 183.6 201.0 209.8 216.1 241.6 250.0 255.7
48.5 51.4 53.8 58.9 61.5 63.3 70.8 73.3 74.9
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 34
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 13.62 0.54 0.75 0.96 13.73 0.62 0.87 1.00 13.81 0.71 0.97 1.00 13.78 0.40 0.56 0.73 13.89 0.44 0.63 0.85 13.97 0.49 0.72 0.94 13.97 0.32 0.44 0.58 14.09 0.33 0.49 0.64 14.16 0.35 0.53 0.71
85_F (29_C) Total Cooling Capacity kBtuh kW 150.4 160.0 168.0 185.4 193.6 199.5 227.3 235.1 240.6
44.0 46.9 49.2 54.3 56.7 58.5 66.6 68.9 70.5
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 15.19 0.52 0.76 0.98 15.27 0.61 0.89 1.00 15.37 0.71 1.00 1.00 15.34 0.38 0.55 0.74 15.43 0.43 0.64 0.85 15.54 0.48 0.72 0.96 15.54 0.30 0.44 0.58 15.65 0.31 0.48 0.65 15.72 0.33 0.53 0.72
95_F (35_C) Total Cooling Capacity kBtuh kW 135.2 144.2 152.6 169.3 177.0 182.6 215.5 223.0 227.9
39.6 42.3 44.7 49.6 51.9 53.5 63.2 65.4 66.8
Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 16.95 0.51 0.76 1.00 17.05 0.62 0.92 1.00 17.15 0.72 1.00 1.00 17.13 0.35 0.54 0.74 17.21 0.40 0.63 0.87 17.32 0.46 0.73 0.99 17.35 0.29 0.43 0.59 17.43 0.30 0.48 0.66 17.52 0.33 0.53 0.74
HUMIDITROL® REHEAT OPTION RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
25 TON HIGH EFFICIENCY − LGC300S − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
8000 10000 12000 8000 10000 12000 8000 10000 12000
65_F (18_C) Sensible To Total Ratio (S/T)
Total Cooling Capacity
L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665
77.0 82.6 87.2 99.0 103.8 107.2 138.8 143.4 146.6
22.5 24.2 25.5 29.0 30.4 31.4 40.6 42.0 42.9
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.34 .25 .55 .88 8.46 .36 .74 1.00 8.56 .51 .91 1.00 8.52 .17 .35 .55 8.64 .22 .42 .72 8.74 .27 .53 .86 8.76 .23 .35 .47 8.88 .24 .39 .53 8.96 .26 .43 .60
75_F (24_C) Total Cooling Capacity kBtuh kW 62.6 68.0 72.4 90.2 94.8 98.0 122.6 127.2 130.0
18.3 19.9 21.2 26.4 27.8 28.7 35.9 37.2 38.1
85_F (29_C)
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.01 .10 .49 .88 9.14 .27 .74 1.00 9.24 .45 .91 1.00 9.20 .12 .30 .56 9.32 .18 .40 .73 9.42 .24 .52 .89 9.46 .15 .30 .43 9.55 .17 .34 .50 9.65 .19 .39 .59
Total Cooling Capacity kBtuh kW 45.0 50.2 54.6 70.0 74.4 77.6 102.4 106.4 109.2
13.2 14.7 16.0 20.5 21.8 22.7 30.0 31.2 32.0
95_F (35_C)
Sensible To Total Ratio (S/T)
Sensible To Total Ratio (S/T) Comp Comp Motor Motor Dry Bulb Dry Bulb kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 9.59 −.18 .38 .91 27.0 7.9 10.37 −.85 .10 .95 9.71 .10 .71 1.00 32.0 9.4 10.47 −.27 .69 1.00 9.82 .34 .95 1.00 36.6 10.7 10.60 .13 1.00 1.00 9.78 −.08 .15 .47 50.8 14.9 10.54 −.43 −.10 .38 9.89 0 .30 .71 54.8 16.0 10.65 −.29 .14 .71 9.96 .10 .46 .90 57.8 16.9 10.74 −.17 .38 .92 10.00 .02 .19 .35 82.6 24.2 10.78 −.16 .05 .25 10.11 .04 .24 .44 86.4 25.3 10.88 −.12 .12 .37 10.19 .08 .31 .56 89.2 26.1 10.95 −.08 .20 .52 Total Cooling Capacity
25 TON HIGH EFFICIENCY − LGC300S − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature
Total Air Volume
cfm 63F (17C) 67F (19C) 71F (22C)
8000 10000 12000 8000 10000 12000 8000 10000 12000
65_F (18_C) Sensible To Total Ratio (S/T)
Total Cooling Capacity
L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665
238.3 249.9 259.5 269.8 279.9 287.0 320.3 330.0 336.7
69.8 73.2 76.0 79.0 82.0 84.0 93.8 96.6 98.6
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 16.78 .58 .78 .97 17.03 .65 .88 1.00 17.23 .73 .97 1.00 17.16 .44 .59 .74 17.40 .48 .65 .85 17.59 .52 .72 .94 17.65 .36 .48 .60 17.89 .37 .51 .66 18.05 .38 .55 .73
75_F (24_C) Total Cooling Capacity kBtuh kW 219.1 230.4 239.6 256.0 265.5 272.3 298.7 308.2 314.2
64.2 67.5 70.2 75.0 77.7 79.7 87.5 90.2 92.0
85_F (29_C)
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 18.42 .57 .79 .99 18.69 .66 .91 1.00 18.89 .74 1.00 1.00 18.81 .43 .59 .75 19.05 .47 .65 .86 19.24 .51 .74 .96 19.32 .33 .47 .59 19.52 .34 .50 .66 19.72 .36 .54 .73
Total Cooling Capacity kBtuh kW 196.5 207.4 216.6 230.4 239.4 246.1 272.8 281.3 287.1
57.3 60.7 63.4 67.5 70.1 72.1 79.9 82.4 84.1
95_F (35_C)
Sensible To Total Ratio (S/T)
Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.11 .55 .79 1.00 20.35 .65 .93 1.00 20.58 .74 1.00 1.00 20.50 .40 .57 .76 20.74 .44 .64 .88 20.89 .49 .74 .99 20.97 .29 .44 .58 21.20 .31 .49 .65 21.37 .32 .52 .73
Total Cooling Capacity kBtuh kW 173.1 183.7 193.3 205.4 213.9 220.2 246.9 254.9 260.6
50.7 53.8 56.6 60.1 62.6 64.5 72.3 74.6 76.3
Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 22.16 .53 .81 1.00 22.38 .63 .95 1.00 22.64 .75 1.00 1.00 22.53 .35 .55 .77 22.76 .41 .64 .90 22.94 .46 .74 1.00 23.03 .25 .41 .56 23.25 .26 .47 .66 23.40 .29 .51 .73
HIGH ALTITUDE DERATE Units may be installed at altitudes up to 2000 feet (610 m) above sea level without any modification. At altitudes above 2000 feet (610 m), units must be derated to match gas manifold pressures shown in table below. NOTE − This is the only permissible derate for these units. Natural Gas
LPG/Propane
Altitude − ft. ft (m) in. w.g.
kPa
in. w.g.
kPa
2001 − 3000 (610 − 915)
3.6
0.90
10.2
2.54
3001 − 4000 (915 − 1220)
3.5
0.87
9.9
2.46
4001 − 5000 (1220 − 1525)
3.4
0.85
9.6
2.39
5001 − 6000 (1525 − 1830)
3.3
0.82
9.4
2.34
6001 − 7000 (1830 − 2135)
3.2
0.80
9.1
2.26
7001 − 8000 (2135 − 2440)
3.1
0.77
8.8
2.19
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 35
BLOWER DATA 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 − Wet indoor coil air resistance of selected unit. 2 − Any factory installed options air resistance (heat section, economizer, etc.) 3 − Any field installed accessories air resistance (duct resistance, diffuser, etc.) Then determine from blower table blower motor output and drive required. See Pages 39−41 for wet coil and option/accessory air resistance data. See page 38 for factory installed drive kit specifications. Air Volume cfm f (L/s) 4000 (1890) 4250 (2005) 4500 (2125) 4750 (2240) 5000 (2360) 5250 (2475) 5500 (2595) 5750 (2715) 6000 (2830) 6250 (2950) 6500 (3065) 6750 (3185) 7000 (3305) 7250 (3420) 7500 (3540) 7750 (3655) 8000 (3775) 8250 (3895) 8500 (4010) 8750 (4130) 9000 (4245) 9250 (4365) 9500 (4485) 9750 (4600) 10000 (4720) 10250 (4835) 10500 (4955) 10750 (5075) 11000 (5190)
.40 (100) RPM BHP (kW) 545 0.85 (0.63) 555 0.90 (0.67) 565 1.00 (0.75) 575 1.10 (0.82) 585 1.25 (0.93) 595 1.35 (1.01) 605 1.45 (1.08) 615 1.60 (1.19) 630 1.75 (1.31) 640 1.90 (1.42) 650 2.05 (1.53) 665 2.20 (1.64) 675 2.35 (1.75) 690 2.60 (1.94) 700 2.75 (2.05) 715 3.00 (2.24) 725 3.20 (2.39) 740 3.40 (2.54) 750 3.65 (2.72) 765 3.90 (2.91) 780 4.20 (3.13) 790 4.45 (3.32) 805 4.75 (3.54) 820 5.05 (3.77) 835 5.40 (4.03) 845 5.65 (4.21) 860 6.00 (4.48) 875 6.40 (4.77) 890 6.80 (5.07)
.60 (150) RPM BHP (kW) 635 1.10 (0.82) 645 1.25 (0.93) 655 1.35 (1.01) 660 1.45 (1.08) 670 1.60 (1.19) 680 1.70 (1.27) 690 1.85 (1.38) 700 2.00 (1.49) 710 2.15 (1.60) 720 2.35 (1.75) 730 2.50 (1.87) 745 2.70 (2.01) 755 2.90 (2.16) 765 3.10 (2.31) 775 3.30 (2.46) 790 3.55 (2.65) 800 3.80 (2.83) 810 4.00 (2.98) 825 4.30 (3.21) 835 4.55 (3.39) 850 4.85 (3.62) 860 5.15 (3.84) 875 5.45 (4.07) 885 5.75 (4.29) 900 6.15 (4.59) 910 6.45 (4.81) 925 6.85 (5.11) 940 7.25 (5.41) 950 7.60 (5.67)
.80 (200) RPM BHP (kW) 715 1.40 (1.04) 725 1.55 (1.16) 730 1.65 (1.23) 740 1.80 (1.34) 750 1.95 (1.45) 755 2.10 (1.57) 765 2.25 (1.68) 775 2.45 (1.83) 785 2.60 (1.94) 795 2.80 (2.09) 805 3.00 (2.24) 815 3.20 (2.39) 825 3.40 (2.54) 835 3.65 (2.72) 845 3.85 (2.87) 855 4.10 (3.06) 865 4.35 (3.25) 880 4.65 (3.47) 890 4.90 (3.66) 900 5.20 (3.88) 910 5.50 (4.10) 925 5.85 (4.36) 935 6.15 (4.59) 950 6.55 (4.89) 960 6.85 (5.11) 970 7.20 (5.37) 985 7.65 (5.71) 1000 8.05 (6.01) 1010 8.45 (6.30)
TOTAL STATIC PRESSURE Inches Water Gauge (Pa) 1.00 (250) 1.20 (300) 1.40 (350) 1.60 (400) 1.80 (450) 2.00 (495) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP (kW) (kW) (kW) (kW) (kW) (kW) 785 1.70 850 2.00 910 2.30 965 2.60 1020 2.90 1070 3.25 (1.27) (1.49) (1.72) (1.94) (2.16) (2.42) 795 1.85 855 2.15 915 2.45 970 2.80 1025 3.10 1075 3.45 (1.38) (1.60) (1.83) (2.09) (2.31) (2.57) 800 2.00 865 2.35 925 2.65 980 3.00 1030 3.30 1080 3.65 (1.49) (1.75) (1.98) (2.24) (2.46) (2.72) 810 2.15 870 2.50 930 2.85 985 3.20 1040 3.55 1085 3.90 (1.60) (1.87) (2.13) (2.39) (2.65) (2.91) 815 2.30 880 2.70 940 3.05 995 3.40 1045 3.80 1095 4.15 (1.72) (2.01) (2.28) (2.54) (2.83) (3.10) 825 2.50 890 2.90 945 3.25 1000 3.65 1050 4.00 1100 4.40 (1.87) (2.16) (2.42) (2.72) (2.98) (3.28) 835 2.65 895 3.05 955 3.45 1010 3.85 1060 4.25 1110 4.70 (1.98) (2.28) (2.57) (2.87) (3.17) (3.51) 840 2.85 905 3.25 960 3.65 1015 4.10 1065 4.50 1115 4.95 (2.13) (2.42) (2.72) (3.06) (3.36) (3.69) 850 3.05 910 3.45 970 3.90 1025 4.35 1075 4.80 1120 5.20 (2.28) (2.57) (2.91) (3.25) (3.58) (3.88) 860 3.25 920 3.70 975 4.15 1030 4.60 1080 5.05 1130 5.50 (2.42) (2.76) (3.10) (3.43) (3.77) (4.10) 870 3.45 930 3.95 985 4.40 1040 4.85 1090 5.35 1140 5.85 (2.57) (2.95) (3.28) (3.62) (3.99) (4.36) 880 3.70 940 4.20 995 4.65 1045 5.10 1095 5.60 1145 6.10 (2.76) (3.13) (3.47) (3.80) (4.18) (4.55) 890 3.95 950 4.45 1005 4.95 1055 5.40 1105 5.95 1155 6.45 (2.95) (3.32) (3.69) (4.03) (4.44) (4.81) 900 4.15 955 4.65 1015 5.25 1065 5.75 1115 6.25 1160 6.75 (3.10) (3.47) (3.92) (4.29) (4.66) (5.04) 910 4.45 965 4.95 1020 5.50 1075 6.05 1125 6.60 1170 7.15 (3.32) (3.69) (4.10) (4.51) (4.92) (5.33) 920 4.70 975 5.25 1030 5.80 1080 6.35 1130 6.90 1180 7.50 (3.51) (3.92) (4.33) (4.74) (5.15) (5.60) 930 4.95 985 5.50 1040 6.10 1090 6.70 1140 7.25 1185 7.85 (3.69) (4.10) (4.55) (5.00) (5.41) (5.86) 940 5.25 995 5.85 1050 6.45 1100 7.05 1150 7.65 1195 8.25 (3.92) (4.36) (4.81) (5.26) (5.71) (6.15) 950 5.55 1005 6.15 1060 6.80 1110 7.40 1160 8.05 1205 8.65 (4.14) (4.59) (5.07) (5.52) (6.01) (6.45) 960 5.85 1015 6.45 1070 7.15 1120 7.75 1165 8.35 1215 9.05 (4.36) (4.81) (5.33) (5.78) (6.23) (6.75) 970 6.15 1025 6.80 1080 7.50 1130 8.15 1175 8.75 1220 9.40 (4.59) (5.07) (5.60) (6.08) (6.53) (7.01) 985 6.55 1040 7.20 1090 7.85 1140 8.55 1185 9.20 1230 9.85 (4.89) (5.37) (5.86) (6.38) (6.86) (7.35) 995 6.90 1050 7.60 1100 8.25 1150 8.95 1195 9.60 1240 10.30 (5.15) (5.67) (6.15) (6.68) (7.16) (7.68) 1005 7.20 1060 7.95 1110 8.65 1160 9.40 1205 10.05 1250 10.80 (5.37) (5.93) (6.45) (7.01) (7.50) (8.06) 1015 7.60 1070 8.35 1120 9.05 1170 9.80 1215 10.50 1260 11.25 (5.67) (6.23) (6.75) (7.31) (7.83) (8.39) 1030 8.00 1080 8.75 1135 9.55 1180 10.25 1225 11.00 −−− (5.97) (6.53) (7.12) (7.65) (8.21) 1040 8.40 1095 9.20 1145 10.00 1190 10.70 1235 11.45 −−− (6.27) (6.86) (7.46) (7.98) (8.54) 1055 8.85 1105 9.65 1155 10.45 1200 11.20 −−− −−− (6.60) (7.20) (7.80) (8.36) 1065 9.30 1115 10.05 1165 10.90 −−− −−− −−− (6.94) (7.50) (8.13)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 36
2.20 (545) RPM BHP (kW) 1115 3.55 (2.65) 1120 3.75 (2.80) 1130 4.05 (3.02) 1135 4.25 (3.17) 1140 4.50 (3.36) 1150 4.80 (3.58) 1155 5.10 (3.80) 1160 5.35 (3.99) 1170 5.65 (4.21) 1175 5.95 (4.44) 1185 6.30 (4.70) 1190 6.60 (4.92) 1200 6.95 (5.18) 1205 7.30 (5.45) 1215 7.65 (5.71) 1225 8.05 (6.01) 1230 8.40 (6.27) 1240 8.85 (6.60) 1250 9.25 (6.90) 1255 9.65 (7.20) 1265 10.10 (7.53) 1275 10.55 (7.87) 1285 11.05 (8.24) 1295 11.50 (8.58)
2.40 (595) RPM BHP (kW) 1160 3.85 (2.87) 1165 4.10 (3.06) 1175 4.35 (3.25) 1180 4.65 (3.47) 1185 4.90 (3.66) 1195 5.20 (3.88) 1200 5.50 (4.10) 1205 5.80 (4.33) 1215 6.10 (4.55) 1220 6.45 (4.81) 1225 6.75 (5.04) 1235 7.10 (5.30) 1240 7.45 (5.56) 1250 7.85 (5.86) 1260 8.25 (6.15) 1265 8.60 (6.42) 1275 9.00 (6.71) 1280 9.40 (7.01) 1290 9.85 (7.35) 1300 10.30 (7.68) 1310 10.80 (8.06) 1315 11.20 (8.36)
2.60 (645) RPM BHP (kW) 1205 4.15 (3.10) 1210 4.45 (3.32) 1215 4.70 (3.51) 1225 5.00 (3.73) 1230 5.30 (3.95) 1235 5.60 (4.18) 1240 5.90 (4.40) 1250 6.25 (4.66) 1255 6.55 (4.89) 1265 6.90 (5.15) 1270 7.25 (5.41) 1275 7.60 (5.67) 1285 8.00 (5.97) 1290 8.35 (6.23) 1300 8.75 (6.53) 1305 9.15 (6.83) 1315 9.60 (7.16) 1325 10.05 (7.50) 1330 10.45 (7.80) 1340 10.90 (8.13) 1350 11.40 (8.50)
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
−−−
BLOWER DATA 21, 25, and 30 TON (248H, 300H, and 360H) BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 − Wet indoor coil air resistance of selected unit. 2 − Any factory installed options air resistance (heat section, economizer, etc.) 3 − Any field installed accessories air resistance ( duct resistance, diffuser, etc.) Then determine from blower table blower motor output and drive required. See Page 39−41 for wet coil and option/accessory air resistance data. See Page 38 for factory installed drive kit specifications.
BOLD INDICATES FIELD FURNISHED DRIVE Air Volume cfm f (L/s)
TOTAL STATIC PRESSURE Inches Water Gauge (Pa) .20 (50)
.40 (100)
.60 (150)
.80 (200) 1.00 (250) 1.20 (300) 1.40 (350) 1.60 (400) 1.80 (450) 2.00 (495) 2.20 (545) 2.40 (595) 2.60 (645)
RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW)
6000 (2830)
---
435 1.20 525 1.45 570 1.60 630 2.00 700 2.35 750 2.80 795 3.15 840 3.40 880 3.80 920 4.20 960 4.65 995 5.10 (0.90) (1.08) (1.19) (1.49) (1.75) (2.09) (2.35) (2.54) (2.83) (3.13) (3.47) (3.80)
6500 (3065)
---
445 1.30 530 1.60 580 1.80 640 2.20 705 2.60 755 3.05 800 3.40 845 3.70 885 4.15 925 4.60 965 5.00 1000 5.45 (0.97) (1.19) (1.34) (1.64) (1.94) (2.28) (2.54) (2.76) (3.10) (4.43) (3.73) (4.07)
7000 (3305)
---
455 1.40 535 1.75 590 2.05 650 2.45 710 2.85 760 3.30 805 3.70 850 4.05 890 4.50 930 4.95 970 5.40 1005 5.85 (1.04) (1.31) (1.53) (1.83) (2.13) (2.46) (2.76) (3.02) (3.36) (3.69) (4.03) (4.36)
7500 (3540)
380
1.05 465 1.50 540 1.90 600 2.30 660 2.70 715 3.15 765 3.60 810 4.00 855 4.45 895 4.90 935 5.35 975 5.85 1010 6.30 (0.78) (1.12) (1.42) (1.72) (2.01) (2.35) (2.69) (2.98) (3.32) (3.66) (3.99) (4.36) (4.70)
8000 (3775)
390
1.25 475 1.65 545 2.10 610 2.55 665 2.95 720 3.45 770 3.90 815 4.35 860 4.85 900 5.30 940 5.75 980 6.30 1015 6.75 (0.93) (1.23) (1.57) (1.90) (2.20) (2.57) (2.91) (3.25) (3.62) (3.95) (4.29) (4.70) (5.04)
8500 (4010)
405
1.40 485 1.90 555 2.35 620 2.80 675 3.30 725 3.75 775 4.20 820 4.70 865 5.20 905 5.70 945 6.20 985 6.75 1020 7.25 (1.04) (1.42) (1.75) (2.09) (2.46) (2.80) (3.13) (3.51) (3.88) (4.25) (4.63) (5.04) (5.41)
9000 (4245)
415
1.60 495 2.10 565 2.60 625 3.10 685 3.60 735 4.10 785 4.60 830 5.10 870 5.60 915 6.15 955 6.70 990 7.20 1025 7.70 (1.19) (1.57) (1.94) (2.31) (2.69) (3.06) (3.43) (3.80) (4.18) (4.59) (5.00) (5.37) (5.74)
9500 (4485)
430
1.85 505 2.35 575 2.90 635 3.40 690 3.90 745 4.50 790 4.95 835 5.50 880 6.05 920 6.60 960 7.15 995 7.70 1035 8.30 (1.38) (1.75) (2.16) (2.54) (2.91) (3.36) (3.69) (4.10) (4.51) (4.92) (5.33) (5.74) (6.19)
10,000 (4720)
445
2.10 520 2.65 585 3.20 645 3.75 700 4.30 750 4.85 800 5.40 845 5.95 885 6.50 925 7.05 965 7.65 1000 8.20 1040 8.85 (1.57) (1.98) (2.39) (2.80) (3.21) (6.49) (4.03) (4.44) (4.85) (5.26) (5.71) (6.12) (6.60)
10,500 4955)
455
2.35 530 2.95 595 3.50 655 4.10 710 4.70 760 5.25 805 5.80 850 6.40 895 7.00 935 7.60 970 8.15 1010 8.80 1045 9.40 (1.75) (2.20) (2.61) (3.06) (3.03) (3.92) (4.33) (4.77) (5.22) (5.67) (608) (6.56) (7.01)
11,000 (5190)
470
2.60 545 3.25 605 3.85 665 4.45 720 5.10 765 5.66 815 6.30 860 6.90 900 7.50 940 8.10 980 8.75 1015 9.35 (1.94) (2.42) (2.87) (3.32) (3.80) (4.22) (4.70) (5.15) (5.60) (6.04) (6.53) (6.98)
---
11,500 (5425)
485
2.95 555 3.60 620 4.25 675 4.85 730 5.55 775 6.10 820 6.70 865 7.40 910 8.05 945 8.65 985 9.30 1020 9.95 (2.20) (2.69) (3.17) (3.62) (4.14) (4.55) (5.00) (5.52) (6.01) (6.45) (6.94) (7.42)
---
12,000 (5665)
500
3.30 570 4.00 630 4.65 685 5.30 740 6.00 785 6.60 830 7.25 875 7.95 915 8.60 955 9.25 995 9.95 103010.60 (2.46) (2.98) (3.47) (3.95) (4.480 (4.92) (5.41) (5.93) (6.42) (6.90) (7.42) (7.91)
---
12,500 (5900)
515
3.65 580 4.35 640 5.05 695 5.75 750 6.50 795 7.10 840 7.80 885 8.55 925 9.20 965 9.90 100010.55 1035 11.25 (2.72) (3.25) (3.77) (4.29) (4.85) (5.30) (5.82) (6.38) (6.86) (7.39) (7.87) (8.39)
---
13,000 (6135)
530
4.05 595 4.80 655 5.55 710 6.25 760 7.00 805 7.65 850 8.40 890 9.05 930 9.75 970 10.50 101011.30 (3.02) (3.58) (4.14) (4.66) (5.22) (5.71) (6.27) (6.75) (7.27) (7.83) (8.43)
---
---
13,500 (6370)
545
4.45 610 5.25 665 6.00 720 6.75 770 7.50 815 8.25 860 9.00 900 9.70 940 10.45 980 11.20 (3.32) (3.92) (4.48) (5.04) (5.60) (6.15) (6.71) (7.24) (7.80) (8.36)
---
---
---
14,000 (6605)
560
4.90 620 5.70 680 6.55 730 7.30 780 8.10 825 8.85 870 9.65 910 10.40 950 11.15 (3.66) (4.25) (4.89) (5.45) (6.04) (6.60) (7.20) 7.76) (8.31)
---
---
---
---
14,500 (6845)
575
5.40 635 6.25 690 7.05 745 7.90 790 8.65 835 9.45 880 10.30 920 11.10 (4.03) (4.66) (5.26) (5.89) (6.45) (7.05) (7.68) (8.28)
---
---
---
---
---
15,000 (7080)
590
5.90 650 6.80 705 7.65 755 8.50 800 9.30 845 10.10 890 11.00 (4.40) (5.07) (5.71) (6.340 (6.94) (7.53) (8.21)
---
---
---
---
---
---
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 37
BLOWER DATA CONSTANT AIR VOLUME (CAV) BELT DRIVE KIT SPECIFICATIONS Model No.
Motor Efficiency
Nominal hp
Maximum hp
Nominal kW
Maximum kW
Drive Kit Number
RPM Range
156H
Standard or High
2 hp
2.3
1.5
1.7
A
535 − 725
156H thru 210
Standard
3 hp
3.45
2.2
2.6
A 1
535 − 725 685 − 865
High
3 hp
3.45
2.2
2.6
2
685 − 865
156H thru 300S
Standard or High
5 hp
5.75
3.7
4.3
2 3 4
685 − 865 850 − 1045 945 − 1185
180 thru 300S
Standard or High
7.5 hp
8.63
5.6
6.4
5 6 7
945 − 1185 1045 − 1285 850 − 1045
240 thru 300S
Standard or High
10 hp
11.5
7.5
8.6
6 8
1045 − 1285 1135 − 1365
248H, 300H, and 360H
Standard or High
5 hp
5.75
3.7
4.3
1 2 6
660 − 810 770 − 965 560 − 710
Standard or High
7.5 hp
8.63
5.6
6.4
3 4
715 − 880 770 − 965
Standard or High
10 hp
11.5
7.5
8.6
3 5
715 − 880 850 − 1045
NOTE − Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.
VARIABLE AIR VOLUME (VAV) DRIVE KIT SPECIFICATIONS Model No. 248H, 300H, and 360H
Motor Efficiency
Nominal hp
Nominal kW
Drive Kit Number
Maximum RPM @ 60Hz VFD Output (Fixed Pulley)
Standard or High
5 hp
3.7
1 2 6
810 965 710
Standard or High
7.5 hp
5.6
3 4
880 965
Standard or High
10 hp
7.5
3 5
880 1045
NOTE − Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. For VFD applications, nominal motor output is also maximum usable motor output.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 38
BLOWER DATA 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) FACTORY INSTALLED OPTIONS/FIELD INSTALLED ACCESSORY AIR RESISTANCE Air Volume
cfm
Wet Indoor Coil
Humiditrol Gas Heat Exchanger Hot Gas Low/Std. Heat Med. Heat High Heat Reheat Coil
156H,180H, 156H, 210H, 180S/H 240H, 300S 210H, 240H 156 thru 300S 156 thru 300S 180 thru 300S 300S L/s 210S, 240S in. in. in. in. in. in. Pa Pa Pa w.g. Pa w.g. Pa w.g. Pa w.g. w.g. w.g.
Horizontal Roof Curb
Economizer 156H thru 300S
156H thru 240H
in. w.g.
in. w.g.
Pa
Pa
MERV 11 Filter
300S in. w.g.
Pa
in. w.g.
Pa
4000 1890 .02
5
.04
10
.02
5
.04
10
.06
15
−−−
−−−
.06
15
−−−
.01
2
4250 2005 .02
5
.04
10
.02
5
.04
10
.06
15
−−−
−−−
.07
17
−−−
.01
2
4500 2125 .02
5
.05
12
.02
5
.05
12
.07
17
.09
22
−−−
.07
17
.02
5
.01
2
4750 2240 .02
5
.05
12
.02
5
.05
12
.08
20
.10
25
−−−
.08
20
.03
7
.01
2
5000 2360 .02
5
.05
12
.02
5
.05
12
.09
22
.11
27
−−−
.08
20
.03
7
.01
2
5250 2475 .02
5
.06
15
.03
7
.06
15
.10
25
.12
30
−−−
.09
22
.04
10
.02
5
5500 2595 .02
5
.07
17
.03
7
.06
15
.10
25
.13
32
−−−
.10
25
.04
10
.02
5
5750 2715 .03
7
.07
17
.03
7
.06
15
.11
27
.14
35
−−−
.11
27
.05
12
.02
5
6000 2830 .03
7
.08
20
.03
7
.07
17
.12
30
.15
37
−−−
.11
27
.06
15
.02
5
6250 2950 .03
7
.08
20
.03
7
.07
17
.12
30
.16
40
.01
2
.12
30
.07
17
.02
5
6500 3065 .03
7
.09
22
.04
10
.08
20
.13
32
.17
42
.02
5
.13
32
.08
20
.02
5
6750 3185 .04
10
.10
25
.04
10
.08
20
.14
35
.18
45
.03
7
.14
35
.08
20
.02
5
7000 3305 .04
10
.10
25
.04
10
.09
22
.15
37
.19
47
.04
10
.15
37
.09
22
.03
7
7250 3420 .04
10
.11
27
.04
10
.09
22
.16
40
.20
50
.05
12
.16
40
.10
25
.03
7
7500 3540 .05
12
.12
30
.05
12
.10
25
.17
42
.21
52
.06
15
.17
42
.11
27
.03
7
8000 3775 .05
12
.13
32
.05
12
.11
27
.19
47
.24
60
.09
22
.19
47
.13
32
.04
10
8500 4010 .06
15
.15
37
.05
12
.12
30
.20
50
.26
65
.11
27
.21
52
.15
37
.04
10
9000 4245 .07
17
.16
40
.06
15
.13
32
.23
57
.29
72
.14
35
.24
60
.17
42
.04
10
9500 4485 .08
20
.18
45
.07
17
.14
35
.25
62
.32
80
.16
40
.26
65
.19
47
.05
12
10,000 4720 .08
20
.20
50
.07
17
.16
40
.27
67
.35
87
.19
47
.29
72
.21
52
.06
15
10,500 4955 .09
22
.22
55
.08
20
.17
42
.30
75
.38
94
.22
55
.31
77
.24
60
.06
15
11,000 5190 .11
27
.24
60
.08
20
.18
45
.31
77
.40
99
.25
62
.34
85
.27
67
.07
17
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 39
BLOWER DATA 21, 25, and 30 TON (248H, 300H, and 360H) FACTORY INSTALLED OPTIONS/FIELD INSTALLED ACCESSORY AIR RESISTANCE Air V l Volume
Wet Indoor C il Coil
Gas Heat Exchanger Standard Heat in. w.g. Pa
Medium Heat in. w.g. Pa
High Heat in. w.g. Pa
cfm
L/s
in. w.g.
Pa
6000
2830
.04
10
.12
30
.16
40
.19
6500
3070
.05
13
.13
32
.18
45
7000
3305
.06
15
.14
35
.20
7500
3540
.07
17
.15
37
8000
3775
.08
20
.17
8500
4010
.08
20
9000
4245
.09
9500
4485
10,000
Economizer
Horizontal R f Curb Roof C b
MERV 11 Filt Filter
in. w.g.
Pa
in. w.g.
Pa
in. w.g.
Pa
47
.01
3
.08
20
.01
2
.21
52
.01
3
.09
22
.01
2
50
.24
59
.02
5
.10
25
.01
2
.21
52
.25
62
.02
5
.11
27
.02
5
42
.24
59
.28
70
.02
5
.13
32
.02
5
.20
50
.27
67
.31
77
.03
7
.15
37
.02
5
22
.22
55
.29
72
.34
85
.04
10
.17
42
.02
5
.10
25
.24
60
.32
80
.38
94
.04
10
.19
47
.03
7
4720
.11
27
.27
67
.36
90
.42
104
.05
12
.21
52
.03
7
10,500
4955
.12
30
.30
75
.40
99
.46
114
.06
15
.24
60
.03
7
11,000
5190
.12
30
.33
92
.43
107
.50
137
.07
17
.27
67
.04
10
11,500
5425
.13
32
.37
92
.48
119
.55
137
.08
20
.30
75
.04
10
12,000
5665
.14
35
.40
99
.52
129
.60
149
.10
25
.33
82
.04
10
12,500
5900
.15
37
.44
109
.57
142
.65
162
.11
27
.37
92
.05
12
13,000
6135
.16
40
.48
119
.61
152
.70
174
.13
32
.40
99
.05
12
13,500
6370
.17
42
.53
132
.67
167
.76
189
.14
35
.44
109
.06
15
14,000
6605
.18
45
.57
142
.72
179
.82
204
.16
40
.49
122
.06
15
14,500
6845
.19
47
.62
154
.78
194
.89
221
.18
45
.53
132
.06
15
15,000
7080
.20
50
.68
169
.84
209
.95
236
.21
52
.58
144
.07
17
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 40
BLOWER DATA CEILING DIFFUSER AIR RESISTANCE Step-Down Diffuser RTD11−185 Air Volume
cfm
L/s
2 Ends Open
1 Side/2 Ends Open
Flush Diffuser
RTD11−275 All Ends & Sides Open
2 Ends Open
1 Side/2 Ends Open
LARTD30/36 All Ends & Sides Open
2 Ends Open
1 Side/2 Ends Open
All Ends FD11−185 FD11−275 LAFD30/36 & Sides Open
in. in. in. in. in. in. in. in. in. in. Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa w.g. w.g. w.g. w.g. w.g. w.g. w.g. w.g. w.g. w.g.
in. Pa w.g.
in. w.g.
−−− −−−
Pa
5000
2360
.51
127
.44
109
.39
97
−−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−−
.27
67
−−− −−−
5200
2455
.56
139
.48
119
.42
104 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − −
.30
75
−−− −−−
−−− −−−
5400
2550
.61
152
.52
129
.45
112 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − −
.33
82
−−− −−−
−−− −−−
5600
2645
.66
164
.56
139
.48
119 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − −
.36
90
−−− −−−
−−− −−−
5800
2735
.71
177
.59
147
.51
127 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − −
.39
97
−−− −−−
−−− −−−
6000
2830
.76
189
.63
157
.55
137
6200
2925
.80
199
.68
169
.59
147 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − −
.36
90
.31
77
.27
67
−−− −−− −−− −−− −−− −−−
.42 104 .29 72 .46 114 − − − − − −
−−− −−−
6400
3020
6500
3065
.86 214 .72 179 .63 157 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .50 124 − − − − − − − − − − − − − − − − − − − − − − − − .42 104 .36 90 .31 77 − − − − − − − − − − − − − − − − − − − − − − − − .34 85
−−− −−−
.92
229
.99
6600
3115
.77
191
.67
167 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − −
6800
3210
246
.83
206
.72
174 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − −
7000
3305 1.03 256 3400 1.09 271
.87
216
.76
189
.92
229
.80
199 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − −
7200 7400
.49
122
.41
102
.36
90
−−− −−− −−− −−− −−− −−−
−−− −−− −−− −−−
.54 134 − − − − − − .58 144 − − − − − −
−−− −−−
−−− −−−
.62 154 .40 99 .66 164 − − − − − −
−−− −−−
−−− −−−
3490 1.15 286 .97 241 .84 209 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .70 174 − − − − − − 3540 − − − − − − − − − − − − − − − − − − .51 127 .46 114 .41 102 .37 92 .31 77 .25 62 − − − − − − .45 112
−−− −−− −−− −−−
8000
3585 1.20 301 1.02 254 .88 219 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .74 184 − − − − − − 3775 − − − − − − − − − − − − − − − − − − .59 147 .49 122 .43 107 .42 104 .36 90 .29 72 − − − − − − .50 124
8500
4010
−−− −−− −−− −−− −−− −−−
.69
172
.58
144
.50
124
.48
119
.41
102
.34
85
−−− −−−
.57 142
.39
97
9000
4245
−−− −−− −−− −−− −−− −−−
.79
196
.67
167
.58
144
.55
137
.47
117
.39
97
−−− −−−
.66 164
.44
109
9500
4485
−−− −−− −−− −−− −−− −−−
.89
7500 7600
.29 .34
72 85
221
.75
186
.65
162
.62
154
.53
132
.45
112 − − − − − −
.74 184
.51
127
10,000 4720
− − − − − − − − − − − − − − − − − − 1.00 249
.84
209
.73
182
.70
174
.60
149
.51
127 − − − − − −
.81 201
.57
142
10,500 4955
− − − − − − − − − − − − − − − − − − 1.10 273
.92
229
.80
199
.78
194
.68
169
.58
144 − − − − − −
.89 221
.65
162
11,000 5190
− − − − − − − − − − − − − − − − − − 1.21 301 1.01 251
.88
219
.87
216
.76
190
.65
162 − − − − − −
.96 239
.72
179
11,500 5425
−−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−−
.97
241
.85
211
.73
182 − − − − − − − − − − − −
.81
201
12,000 5665
− − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.08 269
.94
234
.82
204 − − − − − − − − − − − −
.90
223
12,500 5900
− − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.19 296 1.04 259
.91
226 − − − − − − − − − − − −
.99
246
13,000 6135
− − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.30 323 1.15 286 1.00 249 − − − − − − − − − − − − 1.10 274
13,500 6370
− − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.43 356 1.26 313 1.10 374 − − − − − − − − − − − − 1.20 298
14,000 6605
− − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.56 388 1.38 343 1.20 298 − − − − − − − − − − − − 1.31 326
14,500 6845
− − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.69 420 1.50 373 1.31 326 − − − − − − − − − − − − 1.43 356
15,000 7080
− − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.84 457 1.63 405 1.43 356 − − − − − − − − − − − − 1.56 388
POWER EXHAUST FANS STANDARD STATIC OPERATION 156H, 180, 210, 240, and 300S Return Duct Air Volume Negative Static Pressure in. w.g. Pa cfm L/s 0 0 8630 4070
248H, 300H, and 360H Return Duct Air Volume Negative Static Pressure in. w.g. Pa cfm L/s 0 0 12,800 6040
0.05
12
8210
3875
0.05
12
12,200
5760
0.10
25
7725
3645
0.10
25
11,500
5430
0.15
37
7110
3355
0.15
37
10,800
5100
0.20
50
6470
3055
0.20
50
9900
4670
0.25
62
5790
2730
0.25
62
9000
4250
0.30
75
5060
2390
0.30
75
7900
3730
0.35
87
4300
2030
0.35
87
6750
3190
0.40
100
3510
1655
0.40
100
5450
2570
0.45
112
2690
1270
0.45
112
4150
1960
0.50
125
1840
870
0.50
125
2900
1370
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 41
BLOWER DATA CEILING DIFFUSER AIR THROW DATA 1
Model No.
Air Volume cfm
156H Models 180 Models
210 Models 240 Models 300S Models
L/s
Step-Down ft.
1
Effective Throw Range m
Model No.
Flush ft.
m
Air Volume cfm
Diffuser 5600 5800 6000 6200 6400 6600
Model 2645 2740 2830 2925 3020 3115
RTD11−185 39 − 49 12 − 15 42 − 51 13 − 16 44 − 54 13 − 17 45 − 55 14 − 17 46 − 55 14 − 17 57 − 56 14 − 17
FD11−185 28 − 37 9 − 11 29 − 38 9 − 12 40 − 50 12 − 15 42 − 51 13 − 16 53 − 52 13 − 16 45 − 56 14 − 17
Diffuser 7200 7400 7600 7800 8000 8200 8400 8600 8800
Model 3400 3490 3585 3680 3775 3870 3965 4060 4155
RTD11−275 33 − 38 10 − 12 35 − 40 11 − 12 36 − 41 11 − 13 38 − 43 11 − 13 39 − 44 12 − 13 41 − 46 12 − 14 43 − 49 13 − 15 44 − 50 13 − 15 47 − 55 14 − 17
FD11−275 26 − 35 8 − 11 28 − 37 9 − 11 29 − 38 9 − 12 40 − 50 12 − 15 42 − 51 13 − 16 43 − 52 13 − 16 44 − 54 13 − 17 46 − 57 14 − 17 48 − 59 15 − 18
1
Throw is the horizontal or vertical distance an airstream travels on leaving the outletor diffuser before the maximum velocity is reduced to 50 ft. (15 m) per minute. Four sides open.
L/s
Diffuser Model
248H Models 300H Models 360H Models
Effective Throw Range
Step-Down ft.
Flush
m
ft.
LARTD30/36
m
LAFD30/36
9000
4245
40 − 47
12 − 14
29 − 35
8 − 11
9500
4485
43 − 50
13 − 15
33 − 41
10 − 12
10,000
4720
46 − 54
14 − 16
37 − 46
11 − 14
10,500
4955
50 − 58
15 − 18
42 − 51
13 − 15
11,000
4190
53 − 61
16 − 19
46 − 56
14 − 17
11,500
5425
55 − 64
17 − 20
50 − 61
15 − 19
12,000
5665
58 − 67
18 − 20
54 − 66
16 − 20
12,500
5900
61 − 71
19 − 22
58 − 71
18 − 22
13,000
6135
64 − 74
20 − 23
62 − 75
19 − 23
13,500
6370
67 − 77
20 − 23
66 − 79
20 − 24
1
Throw is the horizontal or vertical distance an airstream travels on leaving the outletor diffuser before the maximum velocity is reduced to 50 ft. (15 m) per minute. Four sides open.
OPTIONAL DISCONNECT SWITCH REQUIREMENTS Model No. No
156H
180 210 240 248 300 360
Voltage
Blower Motor hp
208/230v−3ph 208/230v−3ph 460v−3ph 575v−3ph 208/230v−3ph 460v−3ph 575v−3ph 208/230v−3ph 460v−3ph 575v−3ph 208/230v−3ph 460v−3ph 575v−3ph
2, 3 5 2, 3, 5 2, 3, 5 3, 5, 7.5 3, 5, 7.5 3, 5, 7.5 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10
Disconnect Switch 80A 30M39 −−− 30M39 30M39 −−− 30M39 30M39 −−− 30M39 30M39 −−− 30M39 30M39
150A −−− 30M40 −−− −−− 30M40 −−− −−− 30M40 −−− −−− −−− −−− −−−
250A −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− 30M41 −−− −−−
ELECTRICAL DATA 13 TON HIGH EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((3)) Locked rotor amps each (total) Fullloadamps each(total) Condenser F M t FanMotors (4) Lockedrotoramps each(total) Motor Output − hp Evaporator p Bl Blower Motor M t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Exhaust Fans P t ti Protection ((amps)) Less Exhaust Fans 2 Minimum Circuit With Exhaust Fans A Ampacity it Less Exhaust Fans (Number)Horsepower (W) Optional p Power E h Exhaust t Fans F Fullloadamps(total) Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating)
2 1.5 7.5 46.9 80 70 70 65
208/230V 14.7 (44.1) 91 (273) 2.4 (9.6) 4.7 (18.8) 3 5 2.2 3.7 10.6 16.7 66 105 80 90 80 90 73 79 68 75 (2) 1/3 (249) 4.8 9.4 15
LGC156H (R−22) 460V 7.1 (21.3) 50 (150) 1.3 (5.2) 2.4 (9.6) 2 3 5 1.5 2.2 3.7 3.4 4.8 7.6 20.4 26.8 45.6 40 40 45 35 40 40 35 36 39 32 34 36 (2) 1/3 (249) 2.6 4.8 15
NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 42
2 1.5 2.7 16.2 30 25 26 24
575V 5.1 (15.3) 37 (111) 1 (4) 1.9 (7.6) 3 5 2.2 3.7 3.9 6.1 23.4 36.6 30 35 25 30 27 29 25 27 (2) 1/3 (249) 2 3.8 15
ELECTRICAL DATA 15 TON STANDARD EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((3)) Locked rotor amps each (total) Fullloadamps each(total) Condenser F M t FanMotors (4) Lockedrotoramps each(total) Motor Output − hp Evaporator p Bl Blower M Motor t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Exhaust Fans P t ti Protection ((amps)) Less Exhaust Fans 2 Minimum Circuit With Exhaust Fans A Ampacity it Less Exhaust Fans (Number)Horsepower (W) Optional p P PowerExhaust E h tF Fans Fullloadamps(total) Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating)
3 2.2 10.6 66 90 80 76 71
208/230V 15.4 (46.2) 124 (372) 2.4 (9.6) 4.7 (18.8) 5 7.5 3.7 5.6 16.7 24.2 105 152 90 110 90 110 82 89 77 84 (2) 1/3 (249) 4.8 9.4 15
LGC180S (R−22) 460V 7.4 (22.2) 59.6 (178.8) 1.3 (5.2) 2.4 (9.6) 3 5 7.5 2.2 3.7 5.6 4.8 7.6 11 26.8 45.6 66 40 45 50 40 40 50 37 40 43 35 37 41 (2) 1/3 (249) 2.6 4.8 15
3 2.2 3.9 23.4 35 30 30 28
575V 5.9 (17.7) 49.4 (148.2) 1 (4) 1.9 (7.6) 5 3.7 6.1 36.6 35 35 32 30 (2) 1/3 (249) 2 3.8 15
7.5 5.6 9 54 40 40 35 33
15 TON HIGH EFFICIENCY ModelNo. LGC180H (R−22) Linevoltagedata−60Hz−3phase 208/230V 460V 575V Rated load amps each (total) 17.3 (51.9) 9 (27) 7.1 (21.3) Compressors p ((3)) Locked rotor amps each (total) 123 (369) 62 (186) 50 (150) Fullloadamps each(total) 2.4 (9.6) 1.3 (5.2) 1 (4) Condenser F M t FanMotors (4) Lockedrotoramps each(total) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Motor Output − hp 3 5 7.5 3 5 7.5 3 5 7.5 Evaporator p Bl Blower M Motor t kW 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 Fullloadamps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Lockedrotoramps 66 105 152 26.8 45.6 66 23.4 36.6 54 1 Maximum Overcurrent With Exhaust Fans 90 100 110 50 50 50 40 40 45 P t ti Protection ((amps)) Less Exhaust Fans 90 90 110 45 50 50 35 40 45 2 Minimum Circuit With Exhaust Fans 82 88 95 42 45 49 33 36 39 A Ampacity it Less Exhaust Fans 77 83 91 40 43 46 31 34 37 (Number)Horsepower (W) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) Optional p P PowerExhaust E h tF Fans Fullloadamps(total) 4.8 2.6 2 Lockedrotoramps(total) 9.4 4.8 3.8 Service Outlet (2) 115 volt GFCI (amp rating) 15 15 15
LGC180H (R−410A) 208/230V 460V 575V 20.5 (61.5) 9.6 (28.8) 7.6 (22.8) 155 (465) 75 (225) 54 (162) 2.4 (9.6) 1.3 (5.2) 1 (4) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) 3 5 7.5 3 5 7.5 3 5 7.5 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 66 105 152 26.8 45.6 66 23.4 36.6 54 110 110 125 50 50 60 40 40 45 110 110 125 50 50 50 40 40 45 92 98 106 44 47 50 35 37 40 87 93 101 42 44 48 33 35 38 (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) 4.8 2.6 2 9.4 4.8 3.8 15 15 15
17.5 TON STANDARD / HIGH EFFICIENCY ModelNo. LGC210S (R−22) LGC210H (R−22) Linevoltagedata−60Hz−3phase 208/230V 460V 575V 208/230V 460V 575V Rated load amps each (total) 14.7 (58.8) 7.1 (28.4) 5.8 (23.2) 14.7 (58.8) 7.1 (28.4) 5.1 (20.4) Compressors p ((4)) Locked rotor amps each (total) 91 (364) 50 (200) 37 (148) 91 (364) 50 (200) 37 (148) Fullloadamps each (total) 2.4 (9.6) 1.3 (5.2) 1 (4) 2.4 (9.6) 1.3 (5.2) 1 (4) Condenser F M t FanMotors (4) Lockedrotoramps each (total) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Motor Output − hp 3 5 7.5 3 5 7.5 3 5 7.5 3 5 7.5 3 5 7.5 3 5 7.5 Evaporator p Bl Blower M Motor t kW 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 Fullloadamps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Lockedrotoramps 66 105 152 26.8 45.6 66 23.4 36.6 54 66 105 152 26.8 45.6 66 23.4 36.6 54 1 Maximum Overcurrent With Exhaust Fans 100 110 125 45 50 60 40 40 45 100 110 125 45 50 60 35 40 45 P t ti (amps) Protection ( ) Less Exhaust Fans 90 100 110 45 50 50 35 40 45 90 100 110 45 50 50 30 35 40 2 Minimum Circuit With Exhaust Fans 88 94 102 43 46 49 35 37 40 88 94 102 43 46 49 32 34 37 A Ampacity it Less Exhaust Fans 83 89 97 41 43 47 33 35 38 83 89 97 41 43 47 30 32 35 (No.)Horsepower (W) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) Optional p P PowerExhaust E h tF Fans Fullloadamps(total) 4.8 2.6 2 4.8 2.6 2 Lockedrotoramps(total) 9.4 4.8 3.8 9.4 4.8 3.8 Service Outlet (2) 115 volt GFCI (amp rating) 15 15 15 15 15 15 NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 43
ELECTRICAL DATA 20 TON STANDARD EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps(total) Condenser F M t FanMotors (4) Lockedrotoramps(total) Motor Output − hp Evaporator p Bl Blower Motor M t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Exhaust Fans P t ti (amps) Protection ( ) Less Exhaust Fans 2 Minimum Circuit With Exhaust Fans A Ampacity it Less Exhaust Fans (No.)Horsepower (W) Optional p P PowerExhaust E h tF Fans Fullloadamps(total) Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating)
5 3.7 16.7 105 110 100 97 92
208/230V 15.4 (61.6) 124 (469) 2.4 (9.6) 4.7 (18.8) 7.5 10 5.6 7.5 24.2 30.8 152 193 125 125 125 125 105 111 100 106 (2) 1/3 (249) 4.8 9.4 15
LGC240S (R−22) 460V 7.4 (29.6) 59.6 (238.4) 1.3 (5.2) 2.4 (9.6) 5 7.5 10 3.7 5.6 7.5 7.6 11 14 45.6 66 84 50 60 60 50 50 60 47 51 54 45 48 51 (2) 1/3 (249) 2.6 4.8 15
5 3.7 6.1 36.6 40 40 38 36
575V 5.9 (23.6) 49.4 (197.6) 1 (4) 1.9 (7.6) 7.5 5.6 9 54 45 45 41 39 (2) 1/3 (249) 2 3.8 15
10 7.5 11 66 50 50 43 41
20 TON HIGH EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps(total) Condenser F M t FanMotors (4) Lockedrotoramps(total) Motor Output − hp Evaporator p Bl Blower Motor M t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Exhaust Fans P t ti (amps) Protection ( ) Less Exhaust Fans 2 Minimum Circuit With Exhaust Fans A Ampacity it Less Exhaust Fans (No.)Horsepower (W) Optional p P PowerExhaust E h tF Fans Fullloadamps(total) Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating)
LGA240H (R−22) 208/230V 460V 575V 17.3 (69.2) 9 (36) 7.1 (28.4) 123 (492) 62 (248) 50 (200) 2.4 (9.6) 1.3 (5.2) 1 (4) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 110 125 150 60 60 70 45 50 50 110 125 125 60 60 70 45 50 50 105 113 119 54 58 61 43 46 48 100 108 114 52 55 58 41 44 46 (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) 4.8 2.6 2 9.4 4.8 3.8 15 15 15
LGA240H (R−410A) 208/230V 460V 575V 20.5 (82) 9.6 (38.4) 7.6 (30.4) 155 (620) 75 (300) 54 (216) 2.4 (9.6) 1.3 (5.2) 1 (4) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 125 150 150 60 70 70 50 50 60 125 125 150 60 60 70 50 50 50 119 126 133 57 60 63 45 48 50 114 121 128 54 57 60 43 46 48 (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) 4.8 2.6 2 9.4 4.8 3.8 15 15 15
LGA248H (R−22) 208/230V 460V 575V 17.3 (69.2) 9 (36) 7.1 (28.4) 123 (492) 62 (248) 50 (200) 14.4 7.8 6 28.2 14.4 11.4 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 125 125 150 60 70 70 50 50 60 110 125 150 60 60 70 45 50 50 112 120 126 58 61 64 46 49 51 105 113 119 54 58 61 43 46 48 (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) 7.2 3.9 3 14.1 7.2 5.7 15 15 15
LGA248H (R−410A) 208/230V 460V 575V 18.1 (72.4) 9 (36) 6.8 (27.2) 137 (548) 62 (248) 50 (200) 14.4 7.8 6 28.2 14.4 11.4 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 125 125 150 60 70 70 50 50 60 125 125 150 60 60 70 45 50 50 116 123 130 58 61 64 44 47 49 109 116 123 54 58 61 41 44 46 (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) 7.2 3.9 3 14.1 7.2 5.7 15 15 15
21 TON HIGH EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps(total) Condenser F M t FanMotors (6) Lockedrotoramps(total) Motor Output − hp Evaporator p Bl Blower Motor M t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Exhaust Fans P t ti (amps) Protection ( ) Less Exhaust Fans 2 Minimum Circuit With Exhaust Fans A Ampacity it Less Exhaust Fans (No.)Horsepower (W) Optional p P PowerExhaust E h tF Fans Fullloadamps(total) Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating)
NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 44
ELECTRICAL DATA 25 TON STANDARD / HIGH EFFICIENCY ModelNo. LGC300S (R−22) Linevoltagedata−60Hz−3phase 208/230V 460V 575V Rated load amps each (total) 18.6 (74.4) 9 (36) 7.4 (29.6) Compressors p ((4)) Locked rotor amps each (total) 156 (624) 75 (300) 54 (216) No. of motors 4 4 4 Condenser F M t FanMotors Fullloadamps each(total) 3 (12) 1.5 (6) 1.2 (4.8) Lockedrotoramps each(total) 6 (24) 3 (12) 2.9 (11.6) Motor Output − hp 5 7.5 10 5 7.5 10 5 7.5 10 Evaporator p Bl Blower M Motor t kW 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 Fullloadamps 16.7 24.2 30.8 7.6 11 14 6.1 9 11 Lockedrotoramps 105 152 193 45.6 66 84 36.6 54 66 1 Maximum Overcurrent With Exhaust Fans 125 125 150 60 60 70 50 50 60 P t ti (amps) Protection ( ) Less Exhaust Fans 125 125 150 60 60 70 45 50 50 2 Minimum Circuit With Exhaust Fans 113 121 127 55 58 61 45 48 50 A Ampacity it Less Exhaust Fans 108 116 122 52 56 59 43 46 48 (No.)Horsepower (W) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) Optional p P PowerExhaust E h tF Fans Fullloadamps(total) 4.8 2.6 2 Lockedrotoramps(total) 9.4 4.8 3.8 Service Outlet (2) 115 volt GFCI (amp rating) 15 15 15
LGC300H (R−22) 208/230V 460V 575V 18.6 (74.4) 9 (36) 7.4 (29.6) 156 (624) 75 (300) 54 (216) 6 6 6 2.4 (14.4) 1.3 (7.8) 1 (6) 4.7 (28.2) 2.4 (14.4) 1.9 (11.4) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 125 125 150 60 70 70 50 50 60 125 125 125 60 60 70 50 50 50 118 125 132 58 61 64 47 50 52 111 118 125 54 58 61 44 47 49 (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) 7.2 3.9 3 14.1 7.2 5.7 15 15 15
30 TON HIGH EFFICIENCY ModelNo. LGA360H (R−22) Linevoltagedata−60Hz−3phase 208/230V 460V 575V Rated load amps each (total) 30.1 (90.3) 15.5 (46.5) 12.1 (36.3) Compressors p ((3)) Locked rotor amps each (total) 225 (675) 114 (342) 80 (240) Fullloadamps each(total) 2.4 (14.4) 1.3 (7.8) 1 (6) Condenser F M t FanMotors (6) Lockedrotoramps each (total) 4.7 (28.2) 2.4 (14.4) 1.9 (11.4) Motor Output − hp 5 7.5 10 5 7.5 10 5 7.5 10 Evaporator p Bl Blower M Motor t kW 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 Fullloadamps 16.7 24.2 30.8 7.6 11 14 6.1 9 11 Lockedrotoramps 105 152 193 45.6 66 84 36.6 54 66 1 Maximum Overcurrent With Exhaust Fans 150 150 175 80 80 90 60 60 70 P t ti (amps) Protection ( ) Less Exhaust Fans 150 150 150 80 80 80 60 60 60 2 Minimum With Exhaust Fans 137 144 151 70 74 77 55 58 60 Ci Circuit it Ampacity A it Less Exhaust Fans 129 137 143 66 70 73 52 55 57 (No.)Horsepower (W) (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) Optional p P PowerExhaust E h tF Fans Fullloadamps(total) 7.2 3.9 3 Lockedrotoramps(total) 14.1 7.2 5.7 Service Outlet (2) 115 volt GFCI (amp rating) 15 15 15
LGA360H (R−410A) 208/230V 460V 575V 33.3 (99.9) 17.9 (53.7) 11.5 (34.5) 239 (717) 125 (375) 80 (240) 2.4 (14.4) 1.3 (7.8) 1 (6) 4.7 (28.2) 2.4 (14.4) 1.9 (11.4) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 175 175 175 90 90 100 60 60 60 150 175 175 90 90 90 60 60 60 147 155 161 78 81 84 53 56 58 140 147 154 74 77 80 50 53 55 (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) 7.2 3.9 3 14.1 7.2 5.7 15 15 15
NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements.
OUTDOOR SOUND DATA Octave Band Sound Power Levels dB, re 10−12 Watts
1
1
125
250
500
1000
2000
4000
8000
Sound Rating R ti Number (dB)
156H 180S, 180H
97
92
91
88
83
79
72
93
210S, 210H 240S, 240H
94
91
90
87
83
79
72
92
300S
96
93
90
87
82
76
65
93
248H, 300H
95
93
92
88
84
81
75
94
360H
94
93
93
90
86
81
75
95
*Unit *U it Model No.
Center Frequency − HZ
Tested according to ARI Standard 270-95 test conditions and ANSI Standard S1.32-1981.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 45
INSTALLATION CLEARANCES − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S)
OUTDOOR AIR HOOD
*NOTE − 66 in. (1676 mm) Recommended service clearance for blower deck removal
36 (914)
*41 (1041)
36 (914)
NOTE − Top Clearance 60 in. (1524 mm). NOTE − Entire perimeter of unit base requires support when elevated above mounting surface.
36 (914)
NOTE − 60 in. (1524 mm) Recommended service clearance for heat exchanger removal
21, 25, and 30 TON (248H, 300H, and 360H) − Unit With Economizer
OUTDOOR AIR HOOD
*NOTE − 66 in. (1676 mm) Recommended service clearance for blower deck removal
36 (914)
*41 (1041)
36 (914)
NOTE − Top Clearance 60 in. (1524 mm). NOTE − Entire perimeter of unit base requires support when elevated above mounting surface.
36 (914)
NOTE − 60 in. (1524 mm) Recommended service clearance for heat exchanger removal
21, 25, and 30 TON (248H, 300H, and 360H) − Unit With Horizontal Barometric Relief Dampers OPTIONAL BAROMETRIC RELIEF EXHAUST DAMPERS (Field Installed on Return Air Duct)
NOTE Allow adequate clearance for duct and barometric relief damper installation. NOTE Dampers may be installed on each side of return air duct or end to end on one side of return air duct. OUTDOOR AIR HOOD
*NOTE − 66 in. (1676 mm) Recommended service clearance for blower deck removal
*41 (1041)
36 (914)
NOTE − Top Clearance 60 in. (1524 mm). NOTE − Entire perimeter of unit base requires support when elevated above mounting surface. NOTE − 60 in. (1524 mm) Recommended service clearance for heat exchanger removal
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 46
36 (914)
FIELD WIRING
L CONNECTION® SYSTEM CONTROLLER NETWORK CONTROL PANEL
OPTIONAL INDOOR RELATIVE HUMIDITY SENSOR
OPTIONAL DISCONNECT SWITCH
1
F
C
B
A − Three wire power (See unit Electrical Data Table) B − Two wire low voltage 20 AWG minimum C − One twisted pair with shield. Lennox #27M19 (Belden type 88761) or equivalent (Must be daisy chained to each unit if more than one unit is connected to Network Control Panel). D − Four wire low voltage 20 AWG minimum E − Two wire power (115 volt) F − Three conductor twisted with shield. Two single twisted pair cables (Lennox #27M19), one double twisted pair cable (Belden type 88723) or equivalent.
A
SINGLE PACKAGE UNIT
To other units in network (up to 31). C
D C
Field wiring not furnished NOTE All wiring must conform to NEC or CEC and local electrical codes. 1 Optional wall−mount transformer (18M13) may be used to power the NCP instead of using the unit’s 24vac.
B OPTIONAL INDOOR AIR QUALITY CO2 SENSOR
WALL MOUNTED ZONE SENSOR
2 OPTIONAL AFTER HOURS PUSHBUTTON
115 VOLT SERVICE OUTLET
2 For
use with duct mounted zone sensor
E
ALL UNIT CONTROLLER SYSTEMS A B C D
− − − −
Three wire power (See Electrical Data Table) Shielded twisted pair cable Four wire low voltage Two wire low voltage (CPC 810-3062) Three wire low voltage (CSI MR88R) Four wire low voltage (Johnson Metasys UNT) Four wire low voltage (Novar Custom Controller) + 2 wire low voltage (Novar Custom Controller) Seven wire low voltage (Honeywell Excel 10 W7750B) E − Two wire power (115 volt) F − Three conductor twisted with shield. Two single twisted pair cables (Lennox #27M19), one double twisted pair cable (Belden type 88723) or equivalent. − Field wiring not furnished − NOTE − All wiring must conform to NEC or CEC and local electrical codes.
FIELD FURNISHED GLOBAL CONTROLLER
OPTIONAL DISCONNECT SWITCH
B
A SINGLE PACKAGE UNIT
F C
OPTIONAL INDOOR RELATIVE HUMIDITY SENSOR
OPTIONAL INDOOR AIR QUALITY CO2 SENSOR
OPTIONAL ROOM SENSOR
115 VOLT SERVICE OUTLET
D
E
ELECTRO-MECHANICAL, ELECTRONIC OR HONEYWELL T7300 THERMOSTAT CONTROL SYSTEM OPTIONAL NITE THERMOSTAT
OPTIONAL THERMOSTAT
OPTIONAL DISCONNECT SWITCH
C B
A SINGLE PACKAGE UNIT
G OPTIONAL REMOTE TEMPERATURE SENSOR
H OPTIONAL INDOOR RELATIVE HUMIDITY SENSOR
D OPTIONAL INDOOR AIR QUALITY CO2 SENSOR
E
OPTIONAL TIME CLOCK
115 VOLT SERVICE OUTLET
F
A − Three wire power (See Electrical Data Table) B − Six wire low voltage (Electro-Mechanical) Seven wire low voltage (Electronic) Nine wire low voltage (Honeywell T7300) Ten wire low voltage (Honeywell T7300 with Service LED) C − Two wire low voltage (Electro-Mechanical Only) D − Four wire low voltage (All Systems) E − Two wire power F − Two wire power (115 volt) G − Two wire low voltage − Seven wire low voltage (T7300 Room Sensor with override) H − Three conductor twisted with shield. Two single twisted pair cables (Lennox #27M19), one double twisted pair cable (Belden type 88723) or equivalent. Field wiring not furnished NOTE All wiring must conform to NEC or CEC and local electrical codes.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 47
L CONNECTION® BUILDING AUTOMATION SYSTEM Network Control Up To 31 Units − Large LCD Display Screen − Integrates with IMC Control on S−Classt Packaged Units and Non−S−Class Units (with DDC Network Control Thermostat) − 7 Day Programming plus Holidays − Six Different Time/Temperature Schedules per Day − Storage of Last 75 Alarms With Time/Date − Remote Access (with NCP Expanded PC Software)
NCP1 Network Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
59L21
ZONE TEMPERATURE SENSORS (One sensor required per unit) Order No.
Description
Wall−Mount After Hours Override Button − Terminal Block Connection − Network Jack for L Connection PC Software Wall Mounted Zone Sensor − With warmer/cooler adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
56L80
Wall Mounted Zone Sensor − Without warmer/cooler adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
94L60
Miniature Wall−Mount − Terminal Block Connection Miniature Wall Mounted Zone Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
94L61
Wall−Mount − Terminal Block Connection Wall Mounted Zone Sensor − use with Building Controller (BC1) for monitoring critical areas . . . . . . . . .
59M04
Wall−Mount − Leaded Connection Flush Mount Zone Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76M32
Temperature Averaging Kit Two zone sensors for temperature averaging in one room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23M20
Duct−Mount (For return air duct) Duct Mounted Zone Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
56L81
Wall Mounted Zone Humidity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17M50
Duct Mounted Relative Humidity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76M31
ZONE HUMIDITY SENSOR
OUTDOOR TEMPERATURE SENSOR
Mounted in watertight enclosure with a sun shield. Use with Building Controller (BC1) to monitor outdoor temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
59M05
CO2 SENSORS Sensor − white case, CO2 display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor − white case, no display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor − black case, CO2 display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor − duct mounted, black, no display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AFTER HOURS REMOTE OVERRIDE BUTTON
After Hours Remote Override Button − Wall Plate furnished (Use with Duct Mounted Zone Sensor if required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
77N39 87N53 87N52 87N54
56L16
Continued on next page "
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 48
L CONNECTION® BUILDING AUTOMATION SYSTEM Order No.
Description
NETWORK THERMOSTAT CONTROL (REQUIRED) − DDC that allows network control of T−Class Packaged Units or Splits over L Connectiont Network
1
Description
Order No.
NTC1 − 2 Htg.−3 Clg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17M10
PC SOFTWARE FOR SETUP, CONFIGURATION AND SCHEDULE ADJUSTMENT OF THE NETWORK CONTROL PANEL (NCP) Network Control Panel (NCP) Software For Remote/Local NCP access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
96L82
NOTE − Requires PC Converter Kit (96L78) for local access and Network Modem Kit (94L62) for remote access FOR SETUP, CONFIGURATION AND SERVICING OF NETWORK THERMOSTAT CONTROL (NTC) Unit Controller Software For Remote/Local network control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
96L80
NOTE − Requires PC Converter Kit (96L78) for local access and Network Modem Kit (94L62) for remote access NETWORK MODEM KIT − Provides direct digital communication between a single rooftop unit (or network of rooftop units) and the Network Control Panel
Connects phone line directly to L Connection network − Includes modem, PC Converter, cables . . . . . .
94L62
NOTE − Requires either NCP software and/or Unit Controller Software BUILDING CONTROLLER
BC1−1 − Use to control lights, vent hoods, exhaust fans, sprinklers and other devices based upon unit occupied operation or time schedule.
17M12
NETWORK ETHERNET CONVERTER − Required to interface between the L Connection network and an ethernet LAN (local area network).
Includes ethernet converter, L Connection modem converter, cable, and transformer . . . . . . . . . . . . . . .
76M77
NOTE − Requires L Connection Unit Controller and NCP software (version 2.05 or higher). kWH DEMAND CONTROLLER Use with the Building Controller, the monitor sends a 24VAC output to a building control device to load shed when electrical demand is high. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76M33
NOTE − Requires kWH meter with KYZ output. 1
Computer system requirements: IBM compatible PC with Pentium or higher processor, Microsoft® Windows® 95, 98, Me, 2000, XP, or NT®. (Windows® 95, Windows® 98, Windows® Me, Windows® 2000, Windows® XP, and Windows® NT® are registered trademarks of Microsoft Corp.), 256 MB RAM (more memory may be required to run additional applications simultaneously), requires at least 20 MB of free hard drive space, VGA or higher resolution monitor (screen resolution must be 800 X 600 or higher and 256 colors), CD−ROM drive, mouse or compatible pointing device, serial COM port, PC modem (model no. USR5699B, USR5610B, USR5686E, 005686−03, 3CP5610A, 3CP5699A, 005687−03, or USR3686D is recommended) for remote connections.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 49
L CONNECTION® BUILDING AUTOMATION SYSTEM Description
Order No.
Use with the Building Controller and Network Control Panel for automatic lighting control . . . . . . . . . . .
34M67
NEMA Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17M11
For Network Modem Kit or Building Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34M23
For Network Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34M24
AMBIENT LIGHT SENSOR
NEMA 1 ENCLOSURES
NETWORK PHONE LINE AUTO−ROUTER (Allows modem, fax and phone to share one line − routes signal to connect to device automatically) Network Phone Line Auto−Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34M22
NETWORK BUS TO PC CONVERTER KIT Allows PC connection to L Connection network − Required for any L Connection PC software when used on a local network
96L78
500 ft. Roll − RS−485 twisted pair communication wire − plenum rated . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27M19
1000 ft. Roll − RS−485 twisted pair communication wire − plenum rated . . . . . . . . . . . . . . . . . . . . . . . . . . .
94L63
2500 ft. Roll − RS−485 twisted pair communication wire − plenum rated . . . . . . . . . . . . . . . . . . . . . . . . . . .
68M25
COMMUNICATION CABLE
NETWORK CONTROL PANEL WALL TRANSFORMER − Separate power supply for NCP (if desired) Screw terminals
Transformer − 20VA, Class 2, Primary 120V, 60Hz, Secondary 24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18M13
FACTORY INSTALLED COMPONENTS Air Flow Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dirty Filter Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 50
Factory Installed
OPTIONAL UNIT CONTROLLERS − FACTORY OR Field Installed Field Installed Catalog No.
System and Component Description
CPC 810−3062 Control Module/Blower Proving Switch/Return Air Sensor/Discharge Air Sensor/Wiring Harness − Network communications (RS−485, shielded pair twisted wire), 8 analog/digital inputs, 8 form−C relay outputs, 2 analog outputs, 24 VAC, output connections (2 stage heat/2 stage cool, 2 auxiliary outputs (user defined), economizer, fan), input connections (space temperature, discharge and return air temperature, 2 compressor monitoring, 2 aux. inputs (user defined), local override (1 to 240 minutes), Blower Proving Switch monitors blower operation and locks out unit in case of blower failure, Return Air Sensor provides input to module to determine heating or cooling operation and number of stages required, Discharge Air Sensor monitors leaving air temperature during unit operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
71M57
Sensor − Room temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
48J43
Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30K48
NO START
CPC 810-3062 2 Heat/2 Cool Includes: Control Module, Blower Proving Switch, Return Air Sensor, Discharge Air Sensor, Room Sensor (in kits 61J80 and 61J81 Only) and Wiring Harness
NO DIRTY FILTER SWITCH
ROOM SENSOR
(48J43)
(30K48)
STOP
Field Installed Catalog No.
System and Component Description
CSI MR88R Control Module/Blower Proving Switch/Return Air Sensor/Discharge Air Sensor/Wiring Harness − Small point count controller, supports free-form modular DDC programming, intelligent I/STAT for independent local analog or digital control, local override and setpoint adjustment, 4 local or global points, integral start/stop schedule, standalone operation, universal inputs (thermistor, voltage, current, contact), 8 relay or low voltage triac outputs, analog outputs, 7 signal inputs plus power, ISTAT port, MR LAN port (RS−485, shielded pair twisted wire), self test diagnostics with LED readout, input point parameters (normal and narrow range, indoor and outdoor temperature range, individual calibration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
71M56
Sensor − Room temperature sensor with microprocessor data communications and power, alphanumeric LCD display for modes selected, mode selection push buttons for (Function, Call, Service, Change and Select), password protection for Service mode, up to 4 global point assignment with red LED’s to indicate (Set Temp., Fan Speed, Room and Outside) . . . . . . . . . . . . . . . . . . . .
I/STAT (Field Furnished)
Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30K48
NO START
CSI MR88R 2 Heat/2 Cool Includes: Control Module, Blower Proving Switch, Return Air Sensor, Discharge Air Sensor and Wiring Harness
DIRTY FILTER SWITCH
(30K48)
STOP
HONEYWELL EXCEL 10 (W7750B) Control Module (W7750B)/Blower Proving Switch/Discharge Air Sensor/Return Air Sensor/Wiring Harness − Standalone control (staged or modulating) of all heating, cooling, mixed air, system fan and economizer functions, up to four stages of heating/cooling combinations, for single zone applications, 6 relay outputs, 2 digital inputs, 1 resistive analog input, network communications, LonMark compliant, configuration options include: supply fan type of air handler, occupancy sensor, window sensor, wall module option, dirty filter monitor, indoor air quality override and smoke control. modes of operation include: occupied, standby, unoccupied, bypass occupied, override modes, start−up and wait, cooling, heating, emergency heat, off mode, disabled mode, smoke emergency, freeze protect, manual position, fan only and disabled. Blower Proving Switch monitors blower operation and locks out unit in case of blower failure, Return Air Sensor provides input to module to determine heating or cooling operation and number of stages required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
71M59
Sensor − Room temperature, with setpoint knob . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19L21
Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30K48
NO
NO START
HONEYWELL EXCEL 10 (W7750B) 4 Heat/4 Cool Includes: Control Module, Blower Proving Switch, Discharge Air Sensor, Return Air Sensor and Wiring Harness
T7770 ROOM SENSOR
DIRTY FILTER SWITCH
(19L21)
(30K48)
STOP
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 51
OPTIONAL UNIT CONTROLLERS − Factory or Field Installed JOHNSON METASYS UNT Control Module/Blower Proving Switch/Wiring Harness −Standalone control of all heating, cooling and economizer functions, various operation modes (including: occupied, unoccupied, warm-up, standby), network communications, 6 analog inputs, 4 binary inputs, momentary override, zone lighting control, advanced unit diagnostics, indoor air quality control, outdoor air temperature and humidity monitoring, alarm monitoring of: sensors, airflow, economizer, dirty filter, heating /cooling operation, cooling limit, Blower Proving Switch monitors blower operation and locks out unit in case of blower failure, Control module may be used in multi−zone applications (i.e. L−Zone). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
71M62 (208/230V−3ph) 71M63 (460V−3ph) 71M64 (575V−3ph)
Commissioning Tool − Hand−held interface tool, monitor & adjust 36 analog/binary points, carrying case. . . . . . . . . . . . . . . . .
60K37
Sensor − Room temperature, phone jack style wiring, quick−mount design, latching door mechanism, setpoint adjustment (warmer/cooler), optional override button, nickel sensors, options for choosing setpoint, indication, mounting and wiring type, plug for handheld commissioning tool (60K36). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42N44
Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30K48
NO
NO
START
JOHNSON METASYS UNT 2 Heat/2 Cool Includes: Control Module, Discharge Air Sensor, Return Air Sensor, Blower Proving Switch and Wiring Harness
TE-6411 ROOM SENSOR
DIRTY FILTER SWITCH
(42N44)
(30K48)
STOP
NOVAR ETM−2051 Electronic Thermostat Module (ETM)/Blower Proving Switch/Return Air Sensor/Discharge Air Sensor/Wiring Harness − Module monitors unit operation from different sensors installed in unit and monitors unit diagnostic codes of the IMC. The ETM has outputs for 2 stage heat/2 stage cool, 7 relay outputs: fan Cool 1, Cool 2. Heat 1, Heat 2, Economizer, Night Mode, automatic or continuous blower operation, economizer damper operation and night setback, features: day/occupied mode with low enthalpy (outdoor air damper open), high enthalpy (outdoor air damper closed) or night/unoccupied mode (outdoor air damper closed), network communication (RS−485, shielded pair twisted wire), local override (1 to 255 minutes), watchdog function, fail−safe operation, ETM allows units to be daisy chained" together (up to 31 units) to be operated from one central location with an executive" type control processor (on−site or off−site), built-in time delays, built-in unit operating defaults, diagnostic LED’s indicate various operating functions, surge suppression protects ETM against lightning or voltage spikes, Blower Proving Switch monitors blower operation and locks out unit in case of blower failure, Return Air Sensor provides input to ETM module to determine heating or cooling operation and number of stages required, Discharge Air Sensor monitors leaving air temperature during unit operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
71M58
Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30K48
Room Temperature Sensor with Built−in Night Setback Override Button − Provides input to ETM module to determine heating or cooling operation and number of stages required (ordered separately). Override button allows momentary override of night setback during unoccupied mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
67K61
Sensor − Remote switch over . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18L36
NO
NO
NO
START
NOVAR ETM-2051 2 Heat/2 Cool Includes: Control Module, Blower Proving Switch, Return Air Sensor, Discharge Air Sensor and Wiring Harness
ROOM SENSOR W/ NIGHT SETBACK OVERRIDE BUTTON
REMOTE SWITCH OVER SENSOR
DIRTY FILTER SWITCH
(67K61)
(18L36)
(30K48)
STOP
NOVAR CUSTOM CONTROLLER Control Module/Blower Proving Switch/Discharge Air Sensor/Room Air Sensor/Wiring Harness − User definable comfort setpoint, on/off and time of day control, cycle II ventilation control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
71M65
Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30K48
NO START
NOVAR CUSTOM CONTROLLER 2 Heat/2 Cool (48K89) Includes: Control Module, Blower Proving
DIRTY FILTER SWITCH
Switch, Discharge Air Sensor, Room Air Sensor and Wiring Harness
(30K48)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 52
STOP
OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS − Field Installed Field Installed Catalog No.
System and Component Description ELECTRO-MECHANICAL THERMOSTAT Thermostat − Two stage heat & two stage cool with dual temperature levers, subbase choice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Subbase − Manual system switch (Off-Heat-Auto-Cool), fan switch (Auto-On) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Subbase − Non-switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Night Setback Operation − Order components below Heating Thermostat − Single stage heat / Single stage cool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Subbase − Non-switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Time Clock − 7 day operation, indicates day and night periods, 2 hour increments, battery back-up . . . . . . . . . . . . . . . . . . . . . . . Time Clock − 24 hour night setback operation, 15 minute increments, battery back-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blower Proving Switch − Monitors blower operation, locks out unit in case of blower failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13F06 13F17 13F16 12F99 13F16 See Price Book See Price Book 30K49 30K48
NO NON SWITCHING SUBBASE
7 DAY TIME CLOCK
(13F16) START
ELECTRO MECHANICAL THERMOSTAT
(13F06) 2 Heat−2 Cool
NIGHT THERMOSTAT 1 Heat/1 Cool
NON SWITCHING SUBBASE
(12F99)
(13F16)
NO
24 HOUR TIME CLOCK
SWITCHING SUBBASE
(13F17)
NO
BLOWER PROVE SWITCH
DIRTY FILTER SWITCH
(30K49)
(30K48)
ELECTRONIC THERMOSTAT Electronic Thermostat − Any two stage heat/ two stage cool electronic thermostat may be used. . . . . . . . . . . . . . . . . . . . . . . . . . . Time Clock − 7 day operation, indicates day and night periods, 2 hour increments, battery back-up . . . . . . . . . . . . . . . . . . . . . . . Time Clock − 24 hour night setback operation, 15 minute increments, battery back-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blower Proving Switch − Monitors blower operation, locks out unit in case of blower failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOP
See Price Book See Price Book See Price Book 30K49 30K48
LESS ECONOMIZER NO
NO
START 7 DAY TIME CLOCK
*ELECTRONIC ROOM THERMOSTAT 2 Heat−2 Cool WITH ECONOMIZER
* Any 2 stage heat/ 2 stage cool electronic thermostat may be used. See Lennox Price Book, Thermostats and Controls, Tab for selection.
24 HOUR TIME CLOCK
BLOWER PROVE SWITCH
DIRTY FILTER SWITCH
(30K49)
(30K48)
STOP
NO
HONEYWELL T7300 THERMOSTAT Thermostat − Programmable, internal or optional remote temperature sensing (sensor required), touch sensitive keyboard, automatic switching, F or C readout, no anticipator, droop/no droop selection, indicator LED’s, hour/day programming, override capabilities, time and operational mode readout, stage status indicators, battery back-up, subbase choice, manual system switch (Heat-OffAuto-Cool), fan switch (Auto-On) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Subbase − Selectable staging, indicator LED’s, auxiliary relay output for economizer operation 2 Heat / 2 Cool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Heat / 3 Cool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor − Room temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor − Room temperature with 3 hour override and setpoint adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor − Return air temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blower Proving Switch − Monitors blower operation, locks out unit in case of blower failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37L54
37L55 37L53 58C92 86G67 27C40 30K49 30K48
NO
SWITCHING SUBBASE
(37L55) 2 Heat−2 Cool START
ROOM TEMPERATURE SENSOR
(37L54)
(86G67) SWITCHING SUBBASE
NO
(58C92) ROOM TEMPERATURE SENSOR W/OVERRIDE
T7300 THERMOSTAT
NO
(37L53)
RETURN AIR TEMPERATURE SENSOR
3 Heat−3 Cool
(27C40)
BLOWER PROVE SWITCH
DIRTY FILTER SWITCH
(30K49)
(30K48)
STOP
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 53
DIMENSIONS AND WEIGHTS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) WEIGHTS Model Number
Net lbs.
CORNER WEIGHTS
Shipping kg
AA
BB
CENTER OF GRAVITY
CC
DD
EE
FF
lbs.
kg
lbs.
kg
lbs.
kg
lbs.
kg
lbs.
kg
inch
mm
inch
mm
156H/180 Base Unit
2355 1070
2555
1159
470
213
470
213
650
295
650
295
50
1270
38−1/2
978
156H/180 Max. Unit
2560 1161
2760
1252
580
263
590
268
700
318
690
313
54
1372
41-1/2
1054
210 Base Unit
2485 1127
2685
1218
480
218
460
209
680
308
710
322
52-1/2
1334
37
940
210 Max. Unit
2680 1216
2880
1306
610
277
590
268
730
331
750
304
52-1/2
1334
41
1041
240/300S Base Unit
2535 1150
2735
1241
490
222
520
236
740
336
710
322
54-1/2
1384
37-1/2
953
349
53
1346
40-1/2
1029
240/300S Max. Unit
2740 1243
2940
1334
610
277
610
277
750
304
770
ACCESSORY SHIPPING WEIGHTS (add to base unit weight) High Fire Heat Exchanger
80 lbs.
36 kg
Power Exhaust
62 lbs.
19 kg
Economizer + Hood
151 lbs.
68 kg
LTL Packaging (less than truck load)
280 lbs.
127 kg
Outdoor Air Damper + Hood
117 lbs.
53 kg
Base Unit − The unit with low fire heat exchanger NO OPTIONS. Max. Unit − The unit with ALL OPTIONS Installed. (High Input Heat Exchanger, Economizer, Power Exhaust Fans, Controls)
BB
AA 4-1/4 (108) 12-3/8 (314)
15 (381)
18 (457)
BOTTOM RETURN AIR OPENING
BOTTOM SUPPLY AIR OPENINGS
28 (711) 20 (508)
12-3/8 (314)
60-1/2 (1537)
4-1/2 (114)
28 (711) 20 (508)
EE CENTER OF GRAVITY
FF
4 (102)
DD
CC BOTTOM POWER ENTRY 5 X 8 inches (127 X 203 mm)
4 (102)
TOP VIEW
OPTIONAL DISCONNECT (Factory Installed) GAS SUPPLY INLET (For Bottom Gas Supply Only)
90-1/8 (2289)
132-5/8 (3369) OPTIONAL 115 VOLT OUTLET (Factory Installed Inside Unit)
54-1/4 (1378) 51 (1295) 19-3/8 (492) 1-1/2 (38)
5-3/8 (137) 31-1/2 (800)
SIDE ELECTRICAL INLETS
3-1/4 (83)
CONDENSATE DRAIN
91-1/8 (2315)
END VIEW
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 54
OPTIONAL OUTDOOR GRILLE KIT (Field Installed) (Both Sides)
FLUE OUTLET
GAS SUPPLY INLET
5-7/8 (149)
LIFTING HOLES (For Rigging Front and Back)
FORKLIFT SLOTS (Front and Left Side Only)
107-3/4 (2737)
SIDE VIEW
25-3/8 (645)
ACCESSORY DIMENSIONS − INCHES (MM)
16 (406)
OPTIONAL OUTDOOR AIR HOOD DETAIL
OPTIONAL OUTDOOR AIR HOOD (Factory or Field Installed) Required with Economizer or Outdoor Air Damper
1 OPTIONAL STANDARD STATIC EXHAUST HOOD (Field Installed)
1
Field Installed in Return Air Duct for Horizontal Applications.
HORIZONTAL BAROMETRIC RELIEF DAMPERS (Field installed in horizontal return air duct adjacent to unit) 31−5/8 (803) 29−1/2 (749)
6-1/2 (165)
FRONT VIEW
SIDE VIEW
1
14-1/2 (368) 1 13 (330)
NOTE − Two furnished per order no. 1 NOTE − Opening size required in return air duct.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 55
ACCESSORY DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) STANDARD ROOF CURBS − DOUBLE DUCT OPENING 1-13/16 (46) 1-13/16 (46)
102-1/8 (2594) 98-1/2 (2502)
Frame Opening
8−1/4 (210)
61−1/2 (1562) 16 (406)
NAILER STRIP (Furnished)
CURB RETURN AIR OPENING
17 (432)
14 (356) LARMF18/36-14 24 (610) LARMF18/36-24
3/4 (19) Typ.
82-5/8 (2099) 86-1/8 (2188)
1-13/16 (46)
Frame Opening
102-1/2 (2604)
61-1/2 (1562)
8−1/4 (210)
NOTE Roof deck may be omitted within confines of curb. CURB SUPPLY AIR OPENING
21 (533 )
SIDE VIEW
1-13/16 (46)
A
1 (25) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24
A
NAILER STRIP (Furnished)
2 (51) SECTION A-A
1-13/16 (46)
TOP VIEW
CLIPLOCK 1000 ROOF CURBS − DOUBLE DUCT OPENING
16" (406.4) 86−1/4" (2190.75) 21" (533.4)
102−1/8" (2593.975)
8−1/4" (209.55)
81−1/2" (2070.1) 61−1/2" (1562.1)
17" (431.8)
98−1/2" (2501.9)
RETURN AIR OPENING 8−1/4" (209.55)
SUPPLY AIR OPENING
14 (356) 18 (457) 24 (610)
61−1/2" (1562.1)
DISCARD DUCT SUPPORT WHEN USING FOR OTHER THAN LARMF − 18/36
2" MIN.
FACTORY INSTALLED PERIMETER WOOD NAILER STRIP
CORNER DETAIL TOP EDGE WOOD NAILER STRIP
BOTTOM FLANGE TYPICAL SLOT TYPICAL LOCKING TAB
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 56
ACCESSORY DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) ROOF CURBS WITH LASRT SUPPLY & RETURN AIR TRANSITIONS FOR FD11 & RTD11 CEILING DIFFUSERS 1-13/16 (46)
102-1/8 (2594) 98-1/2 (2502)
1-13/16 (46)
Frame Opening
69-1/4 (1759)
1-13/16 (46)
TRANSITION DETAIL 26-1/2 (673)
LASRT RETURN TRANSITION
Frame Opening
RETURN AIR OPENING
SUPPORT ANGLE (Furnished with Transitions)
A
B
8 (203)
54 (1372)
4-1/2 (114)
82-5/8 (2099)
69-1/4 (1759)
A
SUPPLY AIR OPENINGS
86-1/8 (2188)
A
2 (51)
B
1-1/2 Typ. (38)
B
LASRT SUPPLY TRANSITION
1-13/16 (46) 1 (25) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24
NAILER STRIP (Furnished)
3/4 Typ. (19) A
TRANSITION OPENING SIZES A
2 (51) SECTION A-A
1-13/16 (46)
TOP VIEW INSULATION (Furnished)
10 8 (203) (254)
NAILER STRIP (Furnished)
2 (51)
A
B
Model Number
inch
mm
inch
mm
LASRT18
18
457
36
914
LASRT21/24
24
610
48
1219
14 (356) LARMF18/36-14 24 (610) LARMF18/36-24
102-1/2 (2604)
NOTE Roof deck may be omitted within confines of curb.
SIDE VIEW
ROOF CURB SPECIFICATIONS
TYPICAL FLASHING DETAIL FOR ROOF CURBS
Roof Curb is rigid enough to be spanned over its entire length or cantilevered if supported on both sides of center of gravity. Roof Curb 1
Moment of inertia (I) (in.4) (cm4)
1
Section modulus
I (in.3) (cm3) C
Curb weight. (lb/ft) (kg/m) of length Design strength (psi) (kPa) 1
UNIT BASE BOTTOM
LARMF18/36-14 LARMF18/36-24 39 (1634)
160 (6639)
5.5 (90)
13.1 (512)
5.5 (8.2)
8.5 (12.7)
20,000 (137,900)
UNIT BASE RAIL FIBERGLASS INSULATION (Furnished)
COUNTER FLASHING (Field Supplied)
NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit)
Includes both sides of curb.
CANT STRIP (Field Supplied) ROOFING MATERIAL
RIGID INSULATION (Field Supplied)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 57
ACCESSORY DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) HORIZONTAL ROOF CURBS − Requires Optional Horizontal Return Air Panel Kit 102-1/8 (2594)
1-13/16 (46) 1-13/16 (46)
98-1/2 (2502)
1-13/16 (46)
Frame Opening
NOTE LARMFH18/24-26 and LARMFH30/36-30 are designed for horizontal discharge when unit is mounted on a slab. LARMFH18/24-37 and LARMFH30/36-41 are designed for horizontal discharge when unit is mounted on a rooftop.
Opening
Frame
1-13/16 (46) 1 2 3 4
1 (25)
26 (660) 37 (940) 30 (762) 41 (1041)
A
A
NAILER STRIP (Furnished)
2 (51)
PANEL TO COVER RETURN AIR OPENING IN BOTTOM OF UNIT (Furnished With Optional Horizontal Return Air Panel Kit)
SECTION A-A
82-5/8 (2099) 98-1/2 (2502) 86-1/8 (2188) 54 (1372)
SUPPLY AIR TURNING VANE (Furnished)
SIDE VIEW NOTE − Roof deck may be omitted within confines of curb.
1,2 3,4
TOP VIEW
1-13/16 (46)
(PACKAGED UNIT)
8-1/4 (210) 13-1/4 (337)
NAILER STRIP (Furnished)
86-1/4 (2191)
102-1/8 (2594) 5-1/2 (140) 1 2 3 4
75
26 (660) 37 (940) 30 (762) 41 (1041)
CURB SUPPLY (1905) AIR OPENING With 1-1/2 in. (38 mm) FLANGE
1,2 3,4 1,3 2,4
SUPPLY AIR TURNING VANE (Furnished)
14 (356) 18 (457)
6-1/2 (165) 17-1/2 (445)
102-1/2 (2604)
86-5/8 (2200)
FRONT VIEW 2
1 LARMFH18/24-26
LARMFH18/24-37
3
SUPPLY DUCT PANELS (Furnished)
SIDE VIEW
LARMFH30/36-30 (used with 300S/300H/360 Models)
4 LARMFH30/36-40
(used with 300S/300H/360 Models)
HORIZONTAL SUPPLY AND RETURN AIR OPENINGS WITH HORIZONTAL ROOF CURB OPTIONAL RETURN AIR PANEL KIT (Required For Horizontal Applications)
54-1/4 (1378) 1 2 3 4
76-1/4 (1937) 87-1/4 (2216) 80-1/4 (2038) 91-1/4 (2318)
1 2 3 4
12-3/8 (314)
60-1/2 (1537) 15 (381) HORIZONTAL RETURN AIR OPENING
2 (51) 22 33 26 37
(559) (838) (660) (940)
NOTE − Top of Roof Curb extends 4 inch (102 mm) inside bottom of unit base. See Typical flashing detail.
30-3/8 (772)
75 (1905) 1,2 14 (356) 3,4 18 (457)
HORIZONTAL SUPPLY AIR OPENING
HORIZONTAL ROOF CURB (Required For Horizontal Applications)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 58
1 2 3 4
1,3 2,4
6-1/2 (165) 17-1/2 (445)
LARMFH18/24-26 LARMFH18/24-37 LARMFH30/36-30 (used with 300S Models Only) LARMFH30/36-40 (used with 300S Models Only)
1,2 3,4
8-1/4 (210) 13-1/4 (337)
ACCESSORY DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS
STEP-DOWN CEILING DIFFUSER H
FLUSH CEILING DIFFUSER E
4−5/8 (117)
G
G
F
4−13/16 (122)
F 2 (51)
C 4−5/8 (117)
E B
E
D
4−13/16 (122)
2 (51)
A
A
C
K
G
B
D
RTD11−185
RTD11−275
in.
34
40
mm
864
1016
in.
23−7/8
28−7/8
mm
606
225
in.
10−1/8
11−1/8
Model Number
A B C D E F G H K
Model Number
A B
FD11−185
FD11−275
in.
30−1/8
36−1/8
mm
613
918
in.
47−5/8
59−5/8
mm
1210
1514
in.
45−5/8
57−5/8
mm
257
283
in.
47−5/8
59−5/8
mm
1159
1464
1514
in.
36
48
mm
914
1219
mm
1210
in.
45−5/8
57−7/8
mm
1159
1470
in.
36
48
mm
914
1219
in.
18
24
mm
457
610
in.
45−5/8
57−5/8
mm
1159
1464
in.
47−5/8
59−5/8
mm
1210
1521
C
D
E
F
G
in.
18
24
mm
457
610
in.
45−5/8
57−5/8
mm
1159
1464
in.
47−5/8
59−5/8
mm
1210
1521
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 59
DIMENSIONS AND WEIGHTS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) Shown With Optional Economizer Dampers, Power Exhaust Fans, Convenience Outlet, Unit Disconnect WEIGHTS Model Number
Net lbs.
CORNER WEIGHTS
Shipping kg
AA
BB
CENTER OF GRAVITY
CC
DD
EE
FF
lbs.
kg
lbs.
kg
lbs.
kg
lbs.
kg
lbs.
kg
inch
mm
inch
mm
248H/300H Base Unit
3020 1370
3230
1465
588
267
630
286
932
423
870
395
62-5/8
1591
36-3/4
933
248H/300H Max. Unit
3340 1515
3450
1565
716
325
743
337
958
335
923
419
61-1/4
1556
39-3/4
1010
360 Base Unit
3330 1510
3540
1606
656
298
639
290 1004 455 1031 468
59-3/4
1518
35-3/8
899
360 Max. Unit
3640 1651
3750
1701
785
356
740
336 1025 465 1090 494
58-7/8
1495
38-1/4
972
ACCESSORY SHIPPING WEIGHTS (add to base unit weight) High Fire Heat Exchange
80 lbs.
36 kg
Power Exhaust
90 lbs.
41 kg
Economizer + Hood
195 lbs.
88 kg
LTL Packaging (less than truck load)
300 lbs.
136 kg
Outdoor Air Damper + Hood
148 lbs.
67 kg
Base Unit − The unit with low fire heat exchanger NO OPTIONS. Max. Unit − The unit with ALL OPTIONS Installed. (High Input Heat Exchanger, Economizer, Power Exhaust Fans, Controls)
EE
4-1/4 (108)
AA 5-3/4 (146)
BB
15 (381)
78-1/2 (1994)
18 (457) 17-1/2 (445)
BOTTOM RETURN AIR OPENING CENTER OF GRAVITY
28 28 (711) (711) 4-1/2 20 (508) 20 (508) (114)
FF BOTTOM SUPPLY AIR OPENINGS
4 (102)
DD
CC BOTTOM POWER/GAS ENTRY 5 X 8 inches (127 X 203 mm)
4 (102)
TOP VIEW
OPTIONAL 115 VOLT OUTLET (Factory Installed Inside Unit)
145 (3683) 90-1/8 (2289)
OPTIONAL DISCONNECT (Factory Installed)
65 (1651) SIDE ELECTRICAL INLETS
61-3/4 (1568)
CONDENSATE DRAIN
91-1/8 (2315)
END VIEW
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 60
FLUE OUTLET
OPTIONAL OUTDOOR GRILLE KIT (Field Installed) (Both Sides)
5-3/4 (146)
5-3/8 (137) 31-1/2 (800)
GAS SUPPLY INLET (For Bottom Gas Supply Only)
3-1/4 (83) 4 (102)
FORKLIFT SLOTS (Front and Left Side Only)
119−3/4 (3042)
SIDE VIEW
LIFTING HOLES (For Rigging Front and Back)
25-3/4 (654)
ACCESSORY DIMENSIONS − INCHES (MM) OPTIONAL OUTDOOR AIR HOOD DETAIL
16 (406) OPTIONAL OUTDOOR AIR HOOD (Factory or Field Installed) Required with Economizer or Outdoor Air Damper
1 OPTIONAL STANDARD STATIC EXHAUST HOOD (Field Installed)
1
Field Installed in Return Air Duct for Horizontal Applications.
HORIZONTAL BAROMETRIC RELIEF DAMPERS (Field installed in horizontal return air duct adjacent to unit) 54−1/2 (1384) 52−1/2 (1334)
6-1/2 (165)
1
14-1/2 (368) 1 13 (330)
FRONT VIEW
SIDE VIEW
NOTE − Two furnished per order no. 1 NOTE − Opening size required in return air duct.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 61
ACCESSORY DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) STANDARD ROOF CURBS − DOUBLE DUCT OPENING 1-13/16 (46) 1-13/16 (46)
1-13/16 (46)
102-1/8 (2594) 98-1/2 (2502)
Frame Opening
79-1/2 (2019)
Frame
Opening
1-3/4 (44)
CURB RETURN AIR OPENING
16 (406)
17 (432)
NAILER STRIP (Furnished)
3/4 (19) Typ.
82-5/8 (2099) 86-1/8 (2188)
13-1/4 (337)
14 (356) LARMF18/36-14 24 (610) LARMF18/36-24
61-1/2 (1562) 21 (533)
CURB SUPPLY AIR OPENINGS
102-1/2 (2604) NOTE Roof deck may be omitted within confines of curb.
1-13/16 (46) 1 (25) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24
A
SIDE VIEW
A
NAILER STRIP (Furnished)
2 (51) SECTION A-A
1-13/16 (46)
TOP VIEW
CLIPLOCK 1000 ROOF CURBS − DOUBLE DUCT OPENING 1−3/4" (44.45) 16" (406.4) 86−1/4" (2190.75) 21" (533.4)
114" (2895.6) 81−1/2" (2070.1) 79−1/2" (2019.3)
17" (431.5)
110−3/8" (2803.525)
RETURN AIR OPENING
13−1/4" (336.55)
SUPPLY AIR OPENING
14 (356) 18 (457) 24 (610)
61−1/2" (1562.1)
FACTORY INSTALLED PERIMETER WOOD NAILER STRIP
CORNER DETAIL TOP EDGE WOOD NAILER STRIP
2" MIN. (50.8)
BOTTOM FLANGE TYPICAL SLOT TYPICAL LOCKING TAB
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 62
ACCESSORY DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) ROOF CURBS WITH LASRT SUPPLY & RETURN AIR TRANSITIONS FOR LARTD & LAFD CEILING DIFFUSERS 102-1/8 (2594)
1-13/16 (46) 1-13/16 (46)
98-1/2 (2502)
ROOF CURB DETAIL
1-13/16 (46)
Frame Opening
80-3/4 (2051)
1-13/16 (46)
B
28 (711)
60 (1524)
82-5/8 (2099 )
LASRT RETURN TRANSITION
Frame Opening
RETURN AIR OPENING
1 (25) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24
SUPPORT ANGLE (Furnished with Transitions)
2 (51)
54 (1372)
SECTION A-A
4-1/2 (114)
SUPPLY AIR OPENINGS
28 (711)
TRANSITION DETAIL
LASRT SUPPLY TRANSITION
60 (1524)
86-1/8 (2188)
1-1/2 Typ. (38)
3/4 Typ. (19) A
B
14 12 (305) (356 ) A
26-1/2 (673)
26-1/2 (673)
LASRT SUPPLY TRANSITION
LASRT RETURN TRANSITION
2 (51) 28 (711)
TOP VIEW
1-13/16 (46)
NAILER STRIP (Furnished)
4-1/2 (114)
28 (711)
SECTION B-B INSULATION (Furnished)
14 12 (305) (356 ) 2 (51)
NAILER STRIP (Furnished)
14 (356) LARMF18/36-14 24 (610) LARMF18/36-24
102-1/2 (2604) NOTE Roof deck may be omitted within confines of curb.
SIDE VIEW
ROOF CURB SPECIFICATIONS
TYPICAL FLASHING DETAIL FOR ROOF CURBS
Roof Curb is rigid enough to be spanned over its entire length or cantilevered if supported on both sides of center of gravity. Roof Curb 1
Moment of inertia (I) (in.4) (cm4)
1
Section modulus
I (in.3) (cm3) C
Curb weight. (lb/ft) (kg/m) of length Design strength (psi) (kPa) 1
UNIT BASE BOTTOM
LARMF18/36-14 LARMF18/36-24 39 (1634)
160 (6639)
5.5 (90)
13.1 (512)
5.5 (8.2)
8.5 (12.7)
20,000 (137,900)
UNIT BASE RAIL FIBERGLASS INSULATION (Furnished)
COUNTER FLASHING (Field Supplied)
NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit)
Includes both sides of curb.
CANT STRIP (Field Supplied) ROOFING MATERIAL
RIGID INSULATION (Field Supplied)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 63
ACCESSORY DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) HORIZONTAL ROOF CURBS − Requires Optional Horizontal Return Air Panel Kit 102-1/8 (2594)
1-13/16 (46) 1-13/16 (46)
98-1/2 (2502)
1-13/16 (46)
Frame Opening
NOTE LARMFH30/36-30 is designed for horizontal discharge when unit is mounted on a slab. LARMFH30/36-41 is designed for horizontal discharge when unit is mounted on a rooftop.
1 2 3 4
Opening
Frame
1-13/16 (46) 1 (25)
26 (660) 37 (940) 30 (762) 41 (1041)
A
A
NAILER STRIP (Furnished)
2 (51)
PANEL TO COVER RETURN AIR OPENING IN BOTTOM OF UNIT (Furnished With Optional Horizontal Return Air Panel Kit)
SECTION A-A
82-5/8 (2099) 98-1/2 (2502) 86-1/8 (2188) 54 (1372)
SUPPLY AIR TURNING VANE (Furnished)
SIDE VIEW
NOTE − Roof deck may be omitted within confines of curb.
1-13/16 (46)
(PACKAGED UNIT)
1,2 3,4
TOP VIEW
8-1/4 (210) 13-1/4 (337)
NAILER STRIP (Furnished)
86-1/4 (2191)
102-1/8 (2594) 5-1/2 (140) 1 2 3 4
26 (660) 37 (940) 30 (762) 41 (1041)
75 (1905)
CURB SUPPLY AIR OPENING With 1-1/2 in. (38 mm) FLANGE
1,3 2,4
1,2 3,4
SUPPLY AIR TURNING VANE (Furnished)
14 (356) 18 (457)
6-1/2 (165) 17-1/2 (445)
102-1/2 (2604)
86-5/8 (2200)
FRONT VIEW 1 LARMFH18/24-26
2
LARMFH18/24-37
3
SUPPLY DUCT PANELS (Furnished)
SIDE VIEW
LARMFH30/36-30 (used with 248H/300S/300H/360 Models) 4 LARMFH30/36-40 (used with 248H/300S/300H/360 Models)
HORIZONTAL SUPPLY AND RETURN AIR OPENINGS WITH HORIZONTAL ROOF CURB
OPTIONAL RETURN AIR PANEL KIT (Required For Horizontal Applications
65 (1651) 91 (2311) LARMFH30/36-30 102 (2591) LARMFH30/36-41
78-1/2 (1994) 15 (381)
HORIZONTAL RETURN AIR OPENING
5-1/4 (133)
2 (51) 2
26 (660) LARMFH30/36-30 2 37 (9401) LARMFH30/36-41
2
NOTE − Top of Curb extends 4 inch (102 mm) inside bottom of unit base. See Typical Flashing Detail.
75 (1905) HORIZONTAL SUPPLY AIR OPENING
42-7/8 (1089)
HORIZONTAL ROOF CURB (Required For Horizontal Applications)
SIDE VIEW
(Horizontal Openings)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 64
18 (457)
13-1/4 (337)
6-1/2 (165) LARMFH30/36-30 17-1/2 (445) LARMFH30/36-41
ACCESSORY DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS LARTD30/36 STEP-DOWN CEILING DIFFUSER 63−5/8 (1616) 4−5/8 (117) 28 28 (711) (711)
63−5/8 (1616) 1−13/16 60 (46) (1524)
LAFD30/36 FLUSH CEILING DIFFUSER
2 (51)
63−5/8 (1616) 4−5/8 (117) 28 28 (711) (711)
63−5/8 (1616) 1−13/16 60 (46) (1524)
38−7/8 51 (987)(1295)
2 (51)
46 (1168)
12−1/8 (308) 65−5/8 (1667) 65−5/8 (1667)
65−5/8 (1667)
65−5/8 (1667)
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 65
GUIDE SPECIFICATIONS This MANU−SPEC® utilizes the Construction Specifications Institute (CSI) Manual of Practice, including MasterFormat, SectionFormat and PageFormat. A MANU−SPEC is a manufacturer−specific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text is indicated by brackets [ ]; delete optional text in final copy of specification. Specifier Notes typically precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols are not used in specification text. Metric conversion, where used, is soft metric conversion. This MANU−SPEC specifies Lennox L Series® Rooftop Units. These products are manufactured by Lennox Industries Inc. Revise MANU−SPEC section number and title below to suit project requirements, specification practices and section content. Refer to CSI MasterFormat for other section numbers and titles. SECTION 15730 UNITARY AIR CONDITIONING EQUIPMENT PART 1 GENERAL PART 1.01 A.
SUMMARY Section Includes: Packaged rooftop units and commercial packaged, gas/electric and electric/electric heat pumps.
Specifier Note: Revise paragraph below to suit project requirements. Add section numbers and titles per CSI MasterFormat and specifier’s practice. B.
Related Sections:
Specifier Note: Article below may be omitted when specifying manufacturer’s proprietary products and recommended installation. Retain Reference Article when specifying products and installation by an industry reference standard. If retained, list standard(s) referenced in this section. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of standard referenced. Conditions of the Contract or Division 1 References Section may establish the edition date of standards. This article does not require compliance with standard, but is merely a listing of references used. Article below should list only those industry standards referenced in this section. Retain only those reference standards to be used within the text of this Section. Add and delete as required for specific project. PART 1.02 A.
B.
C.
REFERENCES American National Standards Institute (ANSI): 1.
ANSI/ASHRAE 15 Safety Standard for Refrigeration Systems.
2.
ANSI/ASHRAE/IESNA 90.1 Energy Efficient Design of New Buildings Except Low−Rise Residential Buildings.
3.
ANSI Z21.47 Gas−Fired Central Furnaces.
Air−Conditioning and Refrigeration Institute (ARI): 1.
ARI 210/240 Unitary Air−Conditioning and Air−Source Heat Pump Equipment.
2.
ARI 270 Sound Rating of Outdoor Unitary Equipment.
3.
ARI 340/360 Commercial and Industrial Unitary Air−Conditioning and Heat Pump Equipment.
4.
ARI 370 Sound Rating of Large Outdoor Refrigerating and Air Conditioning Equipment.
American Society of Heating, Refrigerating, and Air−Conditioning Engineers, Inc. (ASHRAE): 1.
ASHRAE 52.2 Method of Testing General Ventilation Air−Cleaning Devices for Removal Efficiency by Particle Size (ANSI approved).
2.
ASHRAE 62.1 Ventilation for Acceptable Indoor Air Quality.
D.
U.S. Energy Policy Act of 1992 (EPACT).
E.
U.S. National Appliance Energy Conservation Act (NAECA): 1.
F.
National Fire Protection Association (NFPA): 1.
G.
NAECA 1988. NFPA 90A Installation of Air Conditioning and Ventilation Systems.
Underwriters Laboratories, Inc. (UL): 1.
UL 1995 Standard for Safety for Heating and Cooling Equipment.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 66
GUIDE SPECIFICATIONS Specifier Note: Article below should be restricted to statements describing design or performance requirements and functional (not dimensional) tolerances of a complete system. Limit descriptions to composite and operational properties required to link components of a system together and to interface with other systems. PART 1.03 SYSTEM DESCRIPTION A. Design Requirements: Provide products and systems that have been manufactured, fabricated and installed to following criteria: 1. ANSI/ASHRAE/IESNA 90.1. 2. ANSI Z21.47. 3. UL 1995. B. Performance Requirements: 1. Packaged Gas Electric: a. Natural Gas Supply Pressure: 7 in. w.c. (1.7 kPa). b. LPG/Propane Supply Pressure: 11 in. w.c. (2.7 kPa). Specifier Note: Specify 208/230 V or 460 V or 575 V, 3−phase for L Series® units from 6 − 30 ton (21.1 − 105.6 kW). Specify 208/230 V, 1−phase, 208/230 V, 460 V, or 575 V, 3−phase for L Series® units from 3 − 5 ton (10.6 − 17.6 kW). 2.
Packaged Cooling: a. Electrical Requirements for Direct Drive Blowers: 60 hz, [208/230 V, 1−phase] [208/230 V, 3−phase] [460 V, 3−phase] [575 V, 3−phase]. Specifier Note: For belt drive blowers from models LCC072S, LCA072H, LCC090S, LCA090H, LCC102S, LCA102H, LCC156H, LCC180S, LCC180H, LCC210S, LCC210H, LCC240S, LCA240H, LCC300S, LCC300H, LCA360H, and LCC360H single phase is not an option. b.
Electrical Requirements for Belt Drive Blowers: 60 hz, [208/230 V, 1−phase] [208/230 V, 3−phase] [460 V, 3−phase] [575 V, 3−phase]. Specifier Note: Available Heat Pump units include LHA090, LHC090, LHA240 and LHC240 only. 3.
Packaged Heat Pumps: a. Electrical Requirements: 60 hz, [208/230 V, 3−phase] [460 V, 3−phase] [575 V, 3−phase]. 4. ARI Rated Net Cooling Efficiency: To meet or exceed ASHRAE Standard 90.1 at rated airflow not less than 350 cfm/ton. Specifier Note: Article below includes submittal of relevant data to be furnished by Contractor before, during or after construction. Coordinate this article with Architect’s and Contractor’s duties and responsibilities in Conditions of the Contract and Division 1 Submittal Procedures Section. PART 1.04 SUBMITTALS A. General: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures. B. Product Data: Submit product data, including manufacturer’s SPEC−DATA® product sheet, for specified products. C. Shop Drawings: 1. Submit shop drawings in accordance with Section 01330 − Submittal Procedures. 2. Indicate: a. Equipment, piping and connections, together with valves, strainers, control assemblies, thermostatic controls, auxiliaries and hardware, and recommended ancillaries which are mounted, wired and piped ready for final connection to building system, its size and recommended bypass connections. b. Piping, valves and fittings shipped loose showing final location in assembly. c. Control equipment shipped loose, showing final location in assembly. d. Dimensions, internal and external construction details, recommended method of installation with proposed structural steel support, mounting curb details, sizes and location of mounting bolt holes; include mass distribution drawings showing point loads. e. Detailed composite wiring diagrams for control systems showing factory installed wiring and equipment on packaged equipment or required for controlling devices or ancillaries, accessories and controllers. f. Details of vibration isolation. g. Estimate of sound levels to be expected across individual octave bands in dB. h. Type of refrigerant used. D. Quality Assurance: 1. Test Reports: Certified test reports showing compliance with specified performance characteristics and physical properties. 2. Certificates: Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements. 3. Manufacturer’s Instructions: Manufacturer’s installation instructions. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 67
GUIDE SPECIFICATIONS Specifier Note: Coordinate paragraph below with Part 3 Field Quality Requirements Article herein. Retain or delete as applicable. E.
Manufacturer’s Field Reports: Manufacturer’s field reports specified.
F.
Closeout Submittals: Submit the following: 1.
Warranty: Warranty documents specified.
2.
Operation and Maintenance Data: Operation and maintenance data for installed products in accordance with Division 1 Closeout Submittals (Maintenance Data and Operation Data) Section. Include methods for maintaining installed products and precautions against cleaning materials and methods detrimental to finishes and performance. Include names and addresses of spare part suppliers.
3.
Provide brief description of unit, with details of function, operation, control and component service.
4.
Commissioning Report: Submit commissioning reports, report forms and schematics in accordance with Section 01810 − Commissioning.
PART 1.05 A.
QUALITY ASSURANCE Qualifications: 1.
Installer experienced in performing work of this section who has specialized in installation of work similar to that required for this project.
2.
Manufacturer Qualifications: Manufacturer capable of providing field service representation during construction and approving application method.
Specifier Note: Paragraph below should list obligations for compliance with specific code requirements particular to this section. General statements to comply with a particular code are typically addressed in Conditions of the Contract and Division 1 Regulatory Requirements Section. Repetitive statements should be avoided. Current data on building code requirements and product compliance may be obtained from filter manufacturer technical support specialists. B.
C.
Regulatory Requirements: Provide [Packaged gas electric] [Packaged cooling] [Packaged heat pump] that complies with the following requirements: 1.
ARI 210/240.
2.
ARI 270.
3.
ARI 340/360.
4.
ASHRAE 52.2.
5.
NFPA 90A.
Preinstallation Meetings: Conduct preinstallation meeting to verify project requirements, manufacturer’s installation instructions and manufacturer’s warranty requirements. Comply with Division 1 Project Management and Coordination (Project Meetings).
PART 1.06
DELIVERY, STORAGE & HANDLING
A.
General: Comply with Division 1 Product Requirements.
B.
Ordering: Comply with manufacturer’s ordering instructions and lead time requirements to avoid construction delays.
C.
Packing, Shipping, Handling and Delivery:
D.
PART 1.07 A.
1.
Deliver materials in manufacturer’s original, unopened, undamaged containers with identification labels intact.
2.
Ship, handle and unload units according to manufacturer’s instructions.
Storage and Protection: 1.
Store materials protected from exposure to harmful weather conditions.
2.
Factory shipping covers to remain in place until installation. PROJECT CONDITIONS
Installation Location: [Confirm design conditions and temperature.].
Specifier Note: Coordinate article below with Conditions of the Contract and with Division 1 Closeout Submittals (Warranty). PART 1.08
WARRANTY
A.
Project Warranty: Refer to Conditions of the Contract for project warranty provisions.
B.
Manufacturer’s Warranty: Submit, for Owner’s acceptance, manufacturer’s standard warranty document executed by authorized company official. Manufacturer’s warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 68
GUIDE SPECIFICATIONS Specifier Note: Coordinate paragraph below with manufacturer’s warranty requirements. C.
Warranty: Commencing on Date of Installation. 1.
Compressors: 5 years (limited).
2.
Integrated Modular Control: 3 years (limited).
3.
Other System Components: 1 year (limited).
4.
Aluminized Heat Exchangers: 10 years (limited).
5.
Stainless Steel Heat Exchangers: 15 years (limited).
PART 2 PRODUCTS Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material standards and descriptions as applicable. Use of such phrases as or equal" or or approved equal" or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for determining or equal" products. PART 2.01 A.
ROOFTOP UNITS Manufacturer: Lennox Industries Inc. 1.
B.
Contact: 2100 Lake Park Blvd., Richardson, TX 75080; Telephone: (800) 453−6669; website: www.lennox.com.
Proprietary Products/Systems: Lennox L Series® Unitary Air Conditioning Equipment, including the following equipment: 1.
2.
Cabinet: Weatherproofing tested and certified to AGA [Rain test standards] and soundproofing tested to ARI 270, dbA at [______] y (______) y (______) m free field. a.
Heavy gauge steel panels and full perimeter heavy gauge galvanized steel base rails.
b.
Raised edges around duct and power entry openings in bottom of unit.
c.
Airflow Configuration: [Down−flow (vertical) return air] [Horizontal return airflow with Horizontal Roof Mounting Frame] [And Horizontal Return Air Panel Kit (required when converting down−flow configured unit to horizontal airflow)].
d.
Power Entry: Electrical [And gas] lines brought through unit base or through horizontal access knockouts.
e.
Exterior Panels: Constructed of heavy gauge, galvanized steel with 2−layer enamel paint finish.
f.
Insulation: All panels adjacent to conditioned air fully insulated with non−hygroscopic fiberglass insulation. Unit base fully insulated.
g.
Base Rail: Full perimeter base rail with rigging holes; 3 sides with fork slots.
h.
Access Panels: Hinged for compressor/controls/heating areas, blower access and air filter/economizer access; and, sealed with quarter−turn latching handles and tight air and water seal.
Compressor: a.
3.
Copeland scroll type, hermetically sealed.
Fans, General: Centrifugal, forward curved impellers, statically and dynamically balanced. [Multi] V−belt drive with adjustable variable pitch motor pulley. a.
Condenser Fan: Low sound operating, PVC coated fan guard, direct drive propeller type fans to discharge vertically.
b.
Condenser Fan Motor: Permanently lubricated, permanent split capacitor; totally enclosed from weather, dust and corrosion; permanently lubricated ball bearings; resiliently mounted; overload protected.
4.
Evaporator Coils: Pressure and leak tested to 500 psi (3445 kPa), nonferrous coils with enhanced aluminum fins mechanically bonded to durable copper tubes.
5.
Condenser Coils: a.
Pressure and leak tested to 500 psi (3445 kPa), nonferrous coils with enhanced aluminum fins mechanically bonded to durable copper tubes.
Specifier Note: Specify slab construction for L Series® over 6 tons (21.1 kW), excluding heat pumps. b. 6.
[Formed construction] [Slab construction].
Air Distribution: a.
Equipment capable of down−flow (vertical) or side (horizontal) handling of conditioned air.
b.
Optional Equipment: L Series Packaged Gas/Electric − 13 to 30 Tons / Page 69
GUIDE SPECIFICATIONS Specifier Note: The following kit is required for horizontal air handling for L Series® 3 − 12 ton (10.6 − 42.2 kW) models. 1)
Horizontal conversion kit for horizontal air handling.
Specifier Note: The following kit is required for horizontal air handling for L Series®, 13 − 30 ton (45.8 − 105.6 kW) models. 2) 7.
Horizontal return air panel kit and horizontal roof mounting frame for horizontal air handling.
Filters: To meet NFPA 90A, air filter requirements [Type Class 1] [Type Class 2]; [______]% efficiency, metal framed, [Replaceable media] [Throwaway] [Standard to unit manufacturer]. a.
Disposable 2 inch (51 mm) pleated MERV 7 rated.
b.
Disposable 2 inch (51 mm) pleated MERV 11 rated.
8.
Heat Exchanger: Removable for servicing; stainless steel optional for applications where mixed air temperature below 45 degrees F (7 degrees C); E.T.L./C.S.A. design certified for outdoor installation.
9.
Gas Heating System: a.
Tubular heat exchanger and inshot type gas burners constructed of aluminized steel.
b.
Direct spark ignition; electronic flame sensor controls; flame rollout switch; limit controls and automatic redundant dual gas valve with staging control and combustion air proving switch on combustion air inducer.
Specifier Note: When LPG/propane is required, specify optional kit.
10.
11.
c.
Able to use LPG/propane [With optional kit].
d.
Complete service access provided for controls and wiring.
Electric Heating System: a.
Available for factory or field installation.
b.
Heating elements of Nichrome bare wire exposed directly to airstream.
Refrigeration System: a.
Self−sealing, discharge, suction and liquid line service gauge ports, freeze−stats, expansion valves and full refrigerant charge.
b.
Copper tubing not to touch sharp metal surfaces.
c.
Compressor Circuits: Automatic reset, high pressure switch; automatic reset, low pressure switch; liquid line filter−drier. Cooling system capable of operating down to 0 deg. F outdoor temperature as shipped from the factory. d. 12.
13.
Capable of operating down to 0 degrees F (−17 degrees C) without installation of additional controls.
Supply Air Blower: a.
[Constant air volume with adjustable pulleys] [Variable air volume with fixed pulleys and variable frequency drive] [Variable air volume with fixed pulleys and variable frequency drive with bypass].
b.
Centrifugal supply air blower with [Permanently lubricated ball bearings and adjustable belt drive] [Sleeve bearings and multi−speed direct drive motor].
c.
Blower assembly [Slides out of unit] [Is accessible] for servicing.
d.
Blower wheel statically and dynamically balanced.
Integrated Modular Control (IMC): a.
Solid−state control board to operate unit.
b.
Built−in functions include: blower on/off delay; built−in control parameter defaults; service relay output; dirty filter switch input; dehumidistat input, economizer control; [Gas valve delay between stages]; [ETM compatible]; [DDC compatible]; unit diagnosis; diagnostics code storage; indoor air quality input; low ambient controls; minimum run time; night setback mode; smoke alarm mode; low pressure control; thermostat bounce delay; 3−digit display; degrees F or degrees C display, 2−stage heat/3−stage cool thermostat compatible and warm−up mode; [Electric heat staging].
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 70
GUIDE SPECIFICATIONS 14.
15.
16.
Gas Heating Controls: a.
Remote thermostat[s] as indicated.
b.
Built−in [Un] fused disconnect switch.
c.
Two stages of heating control from [Thermostat] [DDC].
d.
Supply fan to turn on [40] seconds after heating demand is received with 8 − 60 second adjustable time delay.
e.
Supply fan to turn off [120] seconds after heating demand has ended with 80 − 300 second adjustable time delay.
f.
Adjustable delay time of [30] [Value between 30 − 160] seconds between low and high fire of 2−stage gas valve system.
g.
Heat off delay of [100] [Value between 30 − 300] seconds after thermostat heating demand has ended.
h.
To turn off heat and keep supply air fan running if overheat limit occurs.
i.
Adjustable maximum overheat limit trip count during heating cycle of [3] [Value between 1 − 15], with digital output, limit indicator.
j.
To report error with each occurrence of overheat limit trip and to identify limit that tripped. Error code stored in nonvolatile memory.
k.
To shut off gas heat if flame rollout occurs and to report error identifying rollout switch.
l.
Maximum flame rollout switch trip count of [3] during heating cycle, with digital output, limit indicator. Maximum count limit adjustable from 1 − 6 counts.
m.
To turn off heat if induced airflow is too low and to report error identifying pressure switch.
n.
Maximum induced airflow pressure switch trip count of [3] during heating cycle, with digital output, limit indicator. Maximum count limit adjustable from 1 − 6 counts.
o.
Error reported if gas valve not energized 2 minutes after heating demand; gas valve identified.
p.
Maximum ignition failure count of [3] with digital output, limit indicator. Maximum count limit adjustable from 1 − 6 counts.
q.
To shut off gas valve if flame not sensed. Error reported and stored in nonvolatile memory.
r.
Delay between stages on gas valve.
s.
To shut off unit if gas valve is energized with no demand for heat. Error reported and stored in nonvolatile memory.
Electric Heating Controls: a.
Panel board with [______] stage controller.
b.
Remote thermostat[s] as indicated.
c.
Built−in [Un] fused disconnect switch.
d.
Supply Fan: Start before electric elements are energized and continue operating until bonnet temperature reaches minimum setting. Include switch for continuous fan operation.
e.
Two stages of heating control from [Thermostat] [DDC].
f.
Supply fan to turn off [20] seconds after heating demand has ended. Time delay adjustable from 0 − 300 seconds.
g.
With delay time of [12] seconds between low and high heat stages. Time delay adjustable from 12 − 60 seconds.
h.
To turn off heat and keep supply air fan running if overheat limit occurs.
i.
Adjustable maximum overheat limit trip count of [3] during heating cycle with digital output, limit indicator. Maximum count limit adjustable from 1 − 15 counts.
j.
Error reported and identified if overheat limit tripped. Error code stored in nonvolatile memory.
Cooling Controls: a.
Provide [Smoke detectors in return] [Smoke detectors in supply].
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 71
GUIDE SPECIFICATIONS Specifier Note: Specify b, c or d below. b. c.
[Manual] [Automatic] outside [And return] air dampers for fixed outside air quantity. Remote controlled outside [And return] air dampers with damper operator and means for adjusting outside air quantity. d. Motorized outside, return and [Automatic] [Power exhaust] [Gravity] relief dampers with spring return damper operator and control package to automatically vary outside air quantity. Outside air and exhaust air dampers, normally closed. e. Tight−fitting parallel blade dampers with neoprene or suitable gaskets, synthetic bushings and 1% maximum leakage. f. Damper Operation: 24 V, spring return motor with gear train sealed in oil. g. Mixed Air Controls: [Maintain 55 degrees F (13 degrees C)] [Indicated] mixed air temperature (adjustable). h. Up to 2 stages of cooling from [Thermostat] [External DDC controller] without need for additional controls. i. Up to 3 stages of cooling when used with relay and [3−stage thermostat] [DDC controller]. Specifier Note: Specify article j" when used with Lennox L Connection Network Building Automation System. j. k. l. m. n. o.
p.
q.
r.
s. t. u. v. w. x.
y.
z.
Up to 4 stages of cooling. To allow blower on delay of up to 60 seconds after cooling demand is received. Default value of zero. To allow blower off delay of up to 240 seconds after cooling demand has ended. Default value of zero. Minimum compressor on time of [240] seconds on 3−phase units, adjustable between 60 − 510 seconds. Minimum compressor off time of [300] seconds on single−phase units, adjustable from 60 − 510 seconds. Default maximum high pressure switch trip occurrence during cooling or dehumidification cycle of [3]. Trip occurrence limit adjustable from 1 − 8 occurrences. If maximum limit reached, compressor locked out and digital output for service activated. Default maximum low pressure switch trip occurrence during cooling or dehumidification cycle of [3]. Trip occurrence limit adjustable from 1 − 8 occurrences. If maximum limit reached, compressor locked out and digital output for service activated. Low pressure trip read delay of [5] minutes if compressor off time has been less than 4 hours and outdoor temperature is less than 70 degrees F (21 degrees C). Delay adjustable from 0 − 34 minutes. Temperature set point adjustable from 10 degrees F (−12 degrees C) to 100 degrees F (38 degrees C). Compressor off time adjustable from 1 − 6 hours. Low pressure trip read delay of [15] minutes if compressor off time has been 4 hours or greater and outdoor temperature is less than 70 degrees F (21 degrees C). Delay adjustable from 0 − 34 minutes. Temperature set point adjustable from 10 degrees F (−12 degrees C) to 100 degrees F (38 degrees C). Compressor off time adjustable from 1 − 6 hours. Low pressure trip read delay of [2] minutes if compressor off time has been less than 4 hours and outdoor temperature is 70 degrees F (21 degrees C) or greater. Delay adjustable from 0 − 34 minutes. Temperature set point adjustable from 10 degrees F (−12 degrees C) to 100 degrees F (38 degrees C). Compressor off time adjustable from 1 − 6 hours. Low pressure trip read delay of [8] minutes if compressor off time has been 4 hours or greater and outdoor temperature is 70 degrees F (21 degrees C) or greater. Delay adjustable from 0 − 34 minutes. Temperature set point adjustable from 10 degrees F (−12 degrees C) to 100 degrees F (38 degrees C). Compressor off time adjustable from 1 − 6 hours. Each pressure switch trip occurrence (either high or low) to record error in nonvolatile memory and identify compressor circuit. Low outdoor air temperature compressor lockout set point of 0 degrees F (−18 degrees C) for each compressor circuit. Low outdoor temperature limit set point individually adjustable for each compressor circuit from 80 degrees F (27 degrees C) to −30 degrees F (−34 degrees C). Maximum allowable evaporator freeze−stat trip occurrence of [3] during cooling demand with limit adjustable from 1 − 4 occurrences. Control to shut off compressor each time freeze−stat trip occurs and record error code in nonvolatile memory. If maximum limit reached, compressor locked out and digital output for service activated. Condenser Fan Control: 1) On units with multiple condenser fans, [6] second time delay between condenser fan shutoff and restart to prevent reverse rotation of fan. Time delay adjustable between 0 − 16 seconds. 2) On units with 4 condenser fans, first stage low outdoor temperature set point of 55 degrees F (13 degrees C) that reduces airflow through condenser by turning off some fans. Set point adjustable between 60 degrees F (16 degrees C) and 10 degrees F (−12 degrees C). 3) On units with 6 condenser fans, second stage low outdoor temperature set point of 40 degrees F (4 degrees C) to reduce airflow through condenser by turning off all fans. Set point adjustable between 60 degrees F (16 degrees C) and 10 degrees F (−12 degrees C). 4) On units with 6 condenser fans, condenser fan on delay of [2] seconds. Adjustable between 0 − 240 seconds.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 72
GUIDE SPECIFICATIONS Specifier Note: Edit article below to suit project requirements. If substitutions are permitted, edit text below. Add text to refer to Division 1 Project Requirements (Product Substitutions Procedures) Section. PART 2.02 A.
PRODUCT SUBSTITUTIONS Substitutions: No substitutions permitted.
PART 3 EXECUTION PART 3.01
MANUFACTURER’S INSTRUCTIONS
Specifier Note: Article below is an addition to the CSI SectionFormat and a supplement to MANU−SPEC. Revise article below to suit project requirements and specifier’s practice. A.
Compliance: Comply with manufacturer’s written data, including product technical bulletins, product catalog installation instructions, product carton installation instructions and manufacturer SPEC−DATA® sheets.
PART 3.02 A.
EXAMINATION Site Verification of Conditions: Verify substrate conditions, which have been previously installed under other sections, are acceptable for product installation in accordance with manufacturer’s instructions.
PART 3.03
INSTALLATION
A.
Install [Packaged rooftop units] [And] [Commercial packaged, gas/electric and electric/electric heat pumps] in accordance with manufacturer’s instructions, on roof curbs [Provided by manufacturer] [As indicated].
B.
Run drain line from cooling coil condensation drain pan to discharge [Over roof drain].
PART 3.04
FIELD QUALITY CONTROL
Specifier Note: Use the following Articles only when manufacturer’s field services are desired to verify the quality of the installed components. Establish the number and duration of periodic site visits required by Manufacturer and specify below. Consult Manufacturer for services required. Delete if field services are not required. A.
Have manufacturer of products supplied under this Section review Work involved in handling, installation/application, protection and cleaning of its product[s], and submit written reports in acceptable format to verify compliance of Work with Contract.
B.
Manufacturer’s Field Services: Provide manufacturer’s field services consisting of product use recommendations and periodic site visits for inspection of product installation in accordance with manufacturer’s instructions.
C.
Schedule site visits to review Work at stages listed:
D.
1.
After delivery and storage of products, and when preparatory Work on which Work of this Section depends is complete, but before installation begins.
2.
[Twice] during progress of Work at [25%] and [60%] complete.
3.
Upon completion of Work, after cleaning is carried out.
Obtain reports within [3] days of review and submit.
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 73
GUIDE SPECIFICATIONS PART 3.05 PERFORMANCE VERIFICATION Specifier Note: Commissioning must ensure performance verification of every part of the unit including, but not necessarily limited to, the following components, as a factory−built and packaged unit: (a) mixing chamber or plenum with outside air and return air dampers; filters; either (i) heating coil or (ii) gas−fired heating unit; DX refrigeration system (generally with air−cooled condenser DX cooling coil with drain pan); humidifier; supply fan with motor and drive; exhaust air dampers; weatherproof curbs [Incorporating vibration isolators]. A.
General: 1. Perform rooftop air handling unit verification in accordance with Section 01750 Starting and Adjusting supplemented as follows: 2. Settings: a. Set outside air and return air dampers for minimum outside air. b. Set outside air and return air dampers for percentage of outside air required by design and repeat measurements of fan capacity. 3. Measurements: a. Measure supply fan capacity. b. Measure pressure drop of each component of air handling unit. c. Measure DBT, WBT of SA, RA, EA. d. Measure air cooled condenser discharge DBT. e. Measure flow rates (minimum and maximum) of SA, RA, EA. f. Measure radiated and discharge sound power levels under maximum heating demand and under maximum cooling demand with compressors running. g. Measure DX refrigeration system performance as specified. 4. Simulations: a. Simulate maximum cooling load and measure refrigerant hot gas and suction temperatures and pressures. b. Simulate maximum heating load and: 1) Verify temperature rise across heat exchanger. 2) Perform flue gas analysis. 3) Verify combustion airflow to heat exchanger. 4) Simulate minimum heating load and repeat measurements. 5. Control Strategies: a. Verify operating control strategies, including: 1) Heat exchanger operating and high limit. 2) Early morning warm−up cycle. 3) Freeze protection. 4) Economizer cycle operation, temperature of changeover. 5) Alarms. 6) Voltage drop across thermostat wiring. 7) Operation of remote panel, including pilot lights, failure modes. 6. Operation and Adjustment: a. Check for smooth, vibrationless correct rotation of supply fan impeller. b. Adjust impeller speed as necessary and repeat measurement of fan capacity. c. Reduce differences between fan capacity at minimum and maximum outside air less than [5]%. d. Reduce difference between fan capacity at full cooling and fan capacity at full heating to less than [5]%. e. OAD: Verify for proper travel. f. Use smoke test to verify no short−circuiting of EA, relief air to outside air intake. g. Check for smooth, vibrationless, correct rotation of power exhaust impeller. h. Check capacity of heating unit. i. Refer to other sections of these specifications for PV procedures for other components. PART 3.06 COMPLETION AND CLEANUP A. Upon completion and verification of performance of installation, remove surplus materials, excess materials, rubbish, tools and equipment. END OF SECTION
L Series Packaged Gas/Electric − 13 to 30 Tons / Page 74
Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at 1−800−4−LENNOX
L Series Packaged Gas/Electric − 21 to 30 Ton Variable Air Volume / Page 76