Preview only show first 10 pages with watermark. For full document please download

L061600801 Date: 6/10/2016 6/2/16 6/9/16

   EMBED


Share

Transcript

Report No: L061600801 Date: 6/10/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 L061600801 Report No: Report Prepared For: Model Number: Test: Revolution Lighting Technologies (RVLT) 4139 Guardian Street, Simi Valley, CA 93063 152011-112 Electrical and Photometric tests Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample: Client submitted the sample. Catalog number is 152011-112. Received in working and undamaged condition. No modifications were necessary. Testing Condition: Fixture is tested with no special conditions. Sample Arrival Date: 6/2/16 Date of Tests: 6/9/16 Seasoning of Sample: - 6/10/16 No seasoning was performed in accordance with IESNA LM-79. Equipment List Equipment Used Chroma Programmable AC Source Yokogawa Digital Power Meter Xitron Power Analyzer ITECH DC Power Supply Fluke Digital Thermometer LLI Type C Goniophotometer System LLI 2M Sphere LLI Spectroradiometer Model No Stock No Calibration Due Date 61604 WT210 2503AH IT6122 52k/J RMG-C-MKII 2MR97 SPR-3000 PS-AC02 MT-EL06-S1 MT-EL01 PSDC-03-S1 MT-TP02-GC CD-LL04-GC CD-SN03-S2 MT-SC01-S2 -11/18/16 11/30/16 11/17/16 11/24/16 --Before Use *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 1 of 4 Report No: L061600801 Date: 6/10/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Summary Manufacturer: Model Number: Driver Model Number: Total Lumens: Input Voltage (VAC/60Hz): Input Current (Amp): Input Power (W): Input Power Factor: Current ATHD @ 120V(%): Current ATHD @ 277V(%): Efficacy: Color Rendering Index (CRI): Correlated Color Temperature (K): Chromaticity Coordinate x: Chromaticity Coordinate y: Ambient Temperature (oC): Stabilization Time (Hours): Total Operating Time (Hours): Off State Power(W): Revolution Lighting Technologies (RVLT) 152011-112 TOYOZAKI BSD-E321D-370780 3124.65 120.00 0.27 31.66 1.00 15% N/A 99 84 3535 0.4029 0.3886 25.0 0:40 1:15 0.00 FIG. 1 LUMINAIRE *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 2 of 4 Report No: L061600801 Date: 6/10/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 Percent Output NVLAP LAB CODE 200927-0 Spectral Power 1.0 0.8 0.6 0.4 0.2 0.0 380 Wavelength W/m2nm 380 390 400 410 420 430 0.0007 0.0009 0.0015 0.0056 0.0294 0.1112 CRI & CCT x 0.4029 y 0.3886 u' 0.2350 v' 0.5100 CRI 83.90 CCT 3535 Duv -0.00040 R Values R1 82.50 R2 90.35 R3 95.90 R4 82.59 R5 82.26 R6 86.71 R7 85.75 R8 64.83 R9 14.45 R10 77.04 R11 81.65 R12 65.62 R13 84.40 R14 97.72 430 440 450 460 470 480 490 500 480 530 0.3617 0.8454 0.5409 0.3417 0.2448 0.2885 0.3984 510 520 530 540 550 560 570 580 Wavelength(nm) 0.5093 0.5851 0.6302 0.6720 0.7266 0.7902 0.8569 580 590 600 610 620 630 640 630 680 0.9227 0.9757 1.0000 0.9745 0.9026 0.7987 0.6857 650 660 670 680 690 700 710 730 0.5743 0.4656 0.3652 0.2789 0.2114 0.1572 0.1162 780 720 730 740 750 760 770 780 0.0856 0.0632 0.0465 0.0349 0.0260 0.0194 0.0167 CIE 1931 Chromaticity Diagram Y 0.9 520 0.8 530 540 510 0.7 550 560 0.6 570 500 0.5 580 590 0.4 600 0.4029, 0.3886 0.3 610 620 630 640 650 700 490 0.2 480 0.1 470 460 0 0 0.1 440 430 380 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 3 of 4 Report No: L061600801 Date: 6/10/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each sample. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by : Keyur Patel Test Report Released by: Test Report Reviewed by: Jeff Ahn Engineering Manager Steve Kang Quality Assurance *Attached are photometric data reports. Total number of pages: 9 *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 4 of 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L061600801.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L061600801 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 6/10/2016 [MANUFAC] REVOLUTION LIGHTING TECHNOLOGIES (RVLT) [LUMCAT] 152011-112 [LUMINAIRE] 24"L. X 24"W. X 3.75"H. LED TROFFER [BALLASTCAT] TOYOZAKI BSD-E321D-370780 [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [INPUT] 120VAC, 31.66W [TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height N.A. (absolute) N.A. (absolute) 3125 N.A. 99 31.66 1.00 Direct 1.24 1.34 1.42 Rectangular 1.90 ft 0.63 ft 0.00 ft LUMINANCE DATA (cd/sq.m) Angle In Degrees Average 0-Deg Average 45-Deg Average 90-Deg 45 55 65 75 85 8322 7753 7100 5901 3814 9084 9022 9120 9233 6082 9720 10165 11012 10726 6185 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 1 IES INDOOR REPORT PHOTOMETRIC FILENAME : L061600801.IES CANDELA TABULATION 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0.0 1012 1009 993 966 931 887 835 777 713 655 573 495 414 334 253 170 98 37 0 22.5 1012 1010 995 970 937 895 846 792 731 651 596 522 445 369 289 208 130 49 0 45.0 1012 1011 999 978 949 915 870 821 765 715 644 576 502 429 352 266 162 59 0 67.5 1012 1009 1000 983 958 928 890 849 810 740 685 625 557 487 403 299 180 87 0 90.0 1012 1009 1001 985 963 935 900 861 814 765 709 649 585 518 432 309 182 60 0 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 2 IES INDOOR REPORT PHOTOMETRIC FILENAME : L061600801.IES ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180 371.70 792.12 1305.66 2362.61 3049.87 3124.65 3028.67 933.96 1478.28 1478.77 687.26 265.43 74.78 0.00 0.00 0.00 0.00 0.00 0.00 3124.65 N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. 11.90 25.40 41.80 75.60 97.60 100.00 96.90 29.90 47.30 47.30 22.00 8.50 2.40 0.00 0.00 0.00 0.00 0.00 0.00 100.00 Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 95.98 275.71 420.42 513.55 544.32 512.63 421.83 265.43 74.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 3 IES INDOOR REPORT PHOTOMETRIC FILENAME : L061600801.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 119 119 119 119 108 103 98 94 98 89 82 76 89 78 69 62 81 69 60 53 74 61 52 45 69 55 46 39 64 50 41 34 59 45 37 31 55 41 33 27 52 38 30 25 116 116 116 116 105 101 97 93 95 87 81 75 86 76 68 62 79 67 59 52 72 60 51 45 67 54 45 39 62 49 40 34 58 45 36 30 54 41 33 27 50 38 30 25 111 111 111 96 93 90 84 78 73 73 66 61 65 57 51 58 50 44 52 44 39 47 40 34 43 36 30 40 32 27 37 30 25 106 106 106 92 90 87 80 76 72 70 65 60 62 56 51 56 49 44 50 43 38 46 39 34 42 35 30 39 32 27 36 29 25 102 102 102 89 87 84 77 73 70 68 63 59 60 55 50 54 48 43 49 43 38 44 38 33 41 35 30 38 31 27 35 29 24 100 82 68 56 48 41 36 31 28 25 23 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L061600801.IES POLAR GRAPH 1012 759 506 3 253 2 1 Maximum Candela = 1012 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) # 2 - Vertical Plane Through Horizontal Angles (90 - 270) # 3 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.) Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 5