Transcript
15 14 12 10 9
6
3
2
460-60-3
1
L1
L2
1
Brown/White
2
Black/White
Yellow
3
460V
Red
Phase Monitor
Green
Red/White
T3
L2
T2
T2
L1
T1
T1
Terminal Block #4
L2
1 2 3 4 5 Indoor Blower Motor
L1 L2 L3
3 460
T. Block #2
10
63
L
R
LO
70 41
Yel/Blk 66
68
26 40
Red/White
30
R B
L2
RV
Y
L
CC
L1
C
C
COM
Defrost Control 51 SEN JMP
SENSOR
68
67
Red
L1 Outdoor Fan Motor Controller
L3
Compressor
Low Pressure Switch
3 Way Valve
A
LO COM
Y B
RV
W2
6
7
9
4
Electric Heat Relay (Opt.) Electric Heat Relay
T. Block #2
11
T2
Reversing Valve Low Ambient Bypass
Heater Contactor #2
Gnd
L2 Terminal Block #7
73
7
Reversing Valve
Red
Black
460 Transformer #2
230
Y F
5 1 Plug #2
A
Term. Block #3
C
Heater Contactor #1
C
D
Grn
Black
L1
B2
3
CC
W2
3
A
L. A. Control (Opt.)
Compressor Term. Contactor Term. Defrost Control Block Block #5 RV #5
T. Block #2
D
T1
1
L
Pressure Lockout Indicator
O. Motor Controller
L. A. Bypass (Opt.)
B
6
Red
Red
Purple/White
Tan
Blue
Defrost Sensor
Black
High Press. Switch
H
NC
3
10
Black
12
L2
B1 Terminal Block #6
Black
12
12
Black Low Ambient Control (Opt.)
C RV TWV
Brown
Black
Black
H 7
S
Black
Terminal Block #3 10
S
Blue
Blk
L0
Defrost Sensor
39
Blue
Yellow
T1 T2
L1
42
44
Black
Black/White Tan
LC
42
Blue
Black
5
46
Black/White
T2
35
Red
4
Terminal Block #5 11
Yellow
6
Red
Black
2
T3
28
Red/Black
T1
45
Blue/Black
Terminal 9 Block #4
Low Ambient Bypass (Opt.)
Blue
1
Black
3
47
Blue
Black/White
Red
Ground
Yellow
SENSOR
L2
T. Block #2
9
1 2 3
83 Fuse Block
R
C
T. Block #2
57
Blue
COM
Yo C
8
64
Blue/Red
C
Y
L
27 37
29
TERM SPEED TEMP UP 30 60 90
SENSOR
L1
Low Pressure Term. Block Control #5
Phase Monitor
2 1
Black
460V
32
R W2
Black
Red
Transformer 60
Black
Yo Y C
Yellow
27
L1 L2 L3
R
36
Red
Red/White
Phase Monitor 72
58
Blk/Whte Blk/Whte
Black/White
Yellow
L1
NC
Upper Control Panel
38 27
3 Way Valve
L0
R. Vent Opt. Only
T3
R
C
LC
Lower Control Panel
T2
Plug #1
Transformer
Term. Block High Pressure #5 Control
Yellow/Red
Condenser Section
48
T1
L3
TWV
1
COM
24VAC
56
Red
49
L2
78
80
2
Term. Block #5
50
Black
Yellow/Red
Pink
L1
77
Yellow/Red Pink
59 Comp. Contactor
Yellow
C
Red
Blk/Whte
R
Brown
Blue
W2
Blk/Whte
B
43 F Pressure Lockout Indicator 61
Red/Whte
Blue
Brown
Yellow
Y
G2
4
T1
L1
33
G
T2
Outdoor Fan Motor Controller
31
11 Terminal Block #2
T3
T3
Term. Block #7
Yellow Red Black
Purple/White
L3
Transformer
Black
Brown
Blk/Whte
Blue
25 Plug #3
L1 L3
Orange Orange Red/Yellow Blk/Whte Brown
3 4 5 6 7 8 9 10 11 12
Black
1 2
Purple
Orange
24 Plug #2
Red/Whte
L2
Compressor
Compressor Contactor
L3
240V
23
Indoor Blower Motor
1 2 3 B
C
T. Block #2
D Labeled wires connect if no options used.
Factory
Low Voltage
G
G2
Indoor Blower Motor
Plug #3
Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. Remove jumper when Low Amb. Bypass is H installed.
High Voltage
T. Block #2
1 3 2 9 6 14 12 10 15
Field
Optional
! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C.
!
DANGER
*ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.
Bard Mfg. Co. Bryan, Ohio
4100-319 C