Preview only show first 10 pages with watermark. For full document please download

L2 L3 L1 T1 T2 T3

   EMBED


Share

Transcript

208/230-60-3 POWER SOURCE 11 52 51 4 5 RED 5 PIN PLUG FOR INDOOR BLOWER MOTOR BLACK GREEN 3 BROWN BLUE GRAY YELLOW ORANGE YELLOW YELLOW FREEZE THRMOSTAT PURPLE DEHUM. CONTROL 49 BLACK BLACK/WHITE BLACK 14 12 15 3 1 10 6 9 13 2 RED/WHITE 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 L1 L2 L3 L1 L2 L3 5 Circuit Breaker 19 4 4 Ground Compressor Contactor L1 T1 L2 T2 L3 T3 3 L2 L3 BLUE/BLACK 39 38 RED/WHITE 54 R 240V 31 RED 208V BLACK/WHITE 55 C COM 3 FOR 208 VOLT OPERATION, MOVE THIS RED WIRE TO 208 VOLT TRANSFORMER TAP REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED BLACK/WHITE 1 19 10 24 3 2 35 4 7 G 6 9 14 DEHUM RELAY 12 PIN VENT PLUG 27 3 5 4 6 2 Y1 O 1 W R DEHUM LOGIC 58 36 A Y2 FREEZE T-STAT 4 5 A E TWV BLACK/ WHITE 39 32 A2 G1 Yo A1 G Y D 1 7 8 9 C R C 12 LOW VOLTAGE STRIP 10 11 12 27 RED 12 11 10 9 8 7 6 5 4 3 2 1 12 PIN VENT PLUG 27 High Speed Solenoid 27 BLUE BLACK/WHITE PURPLE BLACK/WHITE 48 Reversing Valve L1 2 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 6 PIN 27 CO2 PLUG 1 BLACK L3 1 3 10 12 PIN PLUG FOR THERMOSTAT BLUE/WHITE BLUE/BLACK RED L2 53 Three way Valve 1 2 3 OPTIONAL 3 PIN PLUG FOR ERV BLUE 27 BLACK/WHITE 2 FOR ANTIFREEZE LOOP APPLICATIONS, CONNECT THE LOW PRESSURE SWITCH WITH YELLOW LEADS IN PLACE OF THE LOW PRESSURE SWITCH WITH BLUE LEADS. ONE LEAD WILL CONNECT TO BROWN LEAD FROM THE FLOW SWITCH, AND THE OTHER WILL CONNECT TO THE YELLOW LEAD COMING FROM THE LPC TERMINAL OF THE COMPRESSOR CONTROL MODULE. C LPC LPC 39 35 18 BLACK/WHITE 39 Check Light 460 VOLT PACKAGE UNIT DIAGRAM Y 2 15 Transformer ALR YELLOW 6 GREEN CC R B L YELLOW 4 5 ORANGE HPC T1 T2 T3 Compressor Contactor LPC THREE WAY VALVE Comp. Control Module 24 YELLOW/RED 38 BROWN 2 12 3 1 REVERSING VALVE BROWN 3 YELLOW 42 RED 2 BLACK/WHITE C Compressor Control Module 34 37 L1 L2 L3 48 27 40 RED 41 BLACK YELLOW RED 1 RED/WHITE L1 L2 L3 43 RED/ WHITE RED/ WHITE ALR LPC BROWN 38 53 9 PINK 44 BLUE 10 C Y 21 Phase Monitor YELLOW B 10 LOW VOLTAGE STRIP 10 13 14 15 6 Y CC R Flow Switch RED A 10 HPC Low Pressure Switch 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 Ground Terminal 4 27 Yout YELLOW/BROWN 9 12 YELLOW 7 RED/WHITE 1 C BLACK 53 6 GREEN PINK 10 4 56 PINK 10 3 RED/WHITE BLUE/BLACK 1 YELLOW 8 9 10 11 12 DEHUM 14 RELAY BROWN RED/WHITE 34 10 BROWN/WHITE 7 PURPLE 10 YELLOW 30 YELLOW BLUE BLACK RED 10 BLUE 5 Circuit Breaker RED BROWN/WHITE 10 6 PIN CO2 PLUG 27 L3 Yo Compressor Contactor 29 99 BLUE 50 PURPLE 5 6 RED/WHITE BLACK/WHITE 10 57 BROWN 4 BLUE BROWN 28 RED/YELLOW BROWN/WHITE ORANGE YELLOW YELLOW 55 BLACK/WHITE 2 3 RED/YELLOW PURPLE PURPLE L2 Y 19 High Pressure Switch 3 BLACK/WHITE BLACK/WHITE 1 54 L1 24VAC ORANGE PURPLE/WHITE COM Transformer YELLOW 10 53 3 2 Compressor 10 YELLOW 10 1 L1 460 12 PIN PLUG FOR THERMOSTAT 10 Optional 3 Pin Plug For ERV 11 5 Pin Plug 5 for Indoor Blower Motor 208/230-60-3 POWER SOURCE YELLOW BLUE Compressor Hi Pressure Control Low Pressure Control ! Low Pressure Control Wire Identification numbers for Bard use only. Factory Field Optional Flow Switch DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. High Voltage Low Voltage 4113-201 D