Preview only show first 10 pages with watermark. For full document please download

La 12v12

   EMBED


Share

Transcript

Valve Regulated Lead-Acid Rechargeable Battery LA-12V12 The battery is constructed by plates, separators, safety valves and container. Since the electrolyte is held by a glassmat separator and plates, the battery can be used in any direction and position without leakage. PERFORMANCE SPECIFICATIONS Nominal Voltage(V)....................................................................................................................12 volts(6cells in series) Nominal Capacity(AH) 20 hour rate F.V.(1.75V/cell) (600mA to 10.50volts) ......................................................................................12A.H. 10 hour rate F.V.(1.75V/cell) (1140mA to10.50volts) ..................................................................................11.4A.H. 5 hour rate F.V.(1.75V/cell) (2040mA to 10.50volts) ...................................................................................10.2A.H. 1 hour rate F.V.(1.55V/cell) (7200mA to 9.30volts)........................................................................................7.2A.H. Approximate Weight............................................................................................................................... 3940g(8.69lbs.) Terminal Standard..........................................................................................................................................................Type T2 Optional............................................................................................................................................................Type T1 Internal Resistance (Fully Charged Battery)........................................................................................................<18m Maximum Discharge Current For 5 sec.(A).............................................................................................................180A Maximum Charge Current(A)....................................................................................................................................3.6A Ambient Temperature Charge....................................................................................................................................0OC(32OF)~40OC(104OF) Discharge.............................................................................................................................-20OC(-4OF)~50OC(122OF) Storage.................................................................................................................................-20OC(-4OF)~40OC(104OF) Vibration test: Frequency: 16.7HZ Amplitude: 4mm Vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality. Case...........................................................................................................................................................................ABS Dimension(mm/inch) Length 1.5mm............................................................................................................................151/5.94 Width 1.5mm..............................................................................................................................98/3.86 Container Height 1.5mm..............................................................................................................................94/3.70 Total Height 2mm.................................................................................................................................98/3.86 Application.........................................................UPS, Laboratory Equipment, Toy-Cars, Power Packs, Fishing Lights. BP12-12 Battery discharge characteristics (25°C/77°F) Battery Charging Characteristics (Typical example of the charge characteristics for the standby use) 140 0.21 15.0 120 0.18 14.0 100 0.15 13.0 13.0 Charge voltage 2.04A 1.14A 0.6A 3A 10.0 7.2A 9.0 80 60 40 Charge voltage(V) 11.0 Charge current(CA) Charge volume(%) Terminal Voltage(V) 12.0 0.12 0.09 0.06 20 0.03 0 0 C ha rg e 1 Discharge 100 %(0.05CA x 20h) 50 %(0.05CA x 10h) 2 Constant voltage charging Charge voltage:2.275V/cell Charge current:0.1CA 3 Temperature:20°C(68°F) 12.0 11.0 10.0 Charge current 8.0 36A 24A 12A 0 5 0 7.0 vo lu m e 1 2 3 5 10 20 30 60 2 3 5 10 20 30 25 Effect of Temperature on Long Term Float Life 10 8 Charging Procedure Temperature Charging compensation Max. charging Voltage current coefficient of O at 20 C (CA) voltage (V/cell) charging (mV/ OC/cell) 2.25~2.30 -3 Charging time O 0.1CA, 20 C (h) Temp O ( C) 100% discharge 24 0.3 50% discharge 20 0~40 O (32~104 F) 2.40~2.50 0.3 -4 16 6 5 4 Life expectancy(year) Constant For standby voltage & power Source Constant current charging For (with current cycle service restriction) 20 Charge time (hr) Discharge time Charging method 15 Hr Min Application 10 Charging voltage : 2.275V/cell 3 2 1 10 0.5 O 20 68 O *Temperature compensation of charging voltage is not needed, when using the batteries within 5 C to 35 C range. 30 86 50 oC 122 oF 40 104 Battery temperature TERMINAL TYPE mm(inch) Terminal T1 98 1.5(3.86 6.35(0.25) 4.75(0.19) 98 2(3.86 0.08) 94 1.5(3.7 0 0.6) 0.06) 7.85(0.31) 0.8(0.03) 6.35(0.25) 1.5(5.94 Discharge time 3.4(0.13) 3.2(0.13) 151 Constant power discharge characteristics at 25 oC/77 oF Terminal T2 0.06) 0.8(0.03) OUTER DIMENSIONS Final Voltage 5Min 10Min 15Min 30Min 10.80V 433.9 319.4 256.0 152.3 87.34 10.50V 502.2 346.0 267.7 158.1 89.96 10.20V 533.6 358.5 276.0 161.7 9.90V 557.5 367.1 282.4 9.60V 576.0 374.4 288.0 5Hr 10Hr 20Hr 34.98 24.12 13.48 7.05 35.68 24.48 13.68 7.20 91.57 36.00 24.61 13.75 7.23 164.0 92.67 36.25 24.70 13.79 7.25 165.6 93.60 36.47 24.77 13.79 7.25 1Hr 3Hr Battery output power(W) TERMINAL POSITION