Transcript
Data sheet LA 11MS Air-to-water heat pump with air deflection hoods Order reference: LA 11MS Installation location: Outdoors Flow temperature max 55 °C Casing, powder-coated Air-to-water heat pump for outdoor installation with outside temperature controlled heat pump controller (manager); sound-optimized through use of low-noise sickle-blade axial fans and air deflection hoods; stainless steel base frame; energy-efficient defrosting through cycle reversal and inclined evaporator. Return sensor and outside temperature sensor supplied with the unit, soft starter is integrated. Electric connecting cable between heat pump and heat pump controller must be ordered separately. The heat pump complies with the valid standards and safety regulations as well as the Technical Specifications for Electrical Installations (TAB) of the electrical utility companies.
Technical data LA 11MS
Dimplex Air-to-water heat pump with air deflection hoods (Low temperature) Order reference Set-up / Colour Temperature operating limits for heating water / Air Temperature operating limits for air Heat output / COP at A-7/W35* Heat output / COP at A+2/W35* Heat output / COP at A+7/W35* Heat output / COP at A+10/W35* Electrical nominal power consumption at A+2/W35 Sound power level Sound pressure level at a distance of 10 m (air outlet side) Refrigerant R404A Flow rate (heat source) Heating water flow rate with an int. pressure differential of Dimensions (W x D x H)** Weight (incl. packing) Control voltage Supply voltage Starting current with soft starter Fuse Defrosting / type of defrosting Device connections for heating
LA 11MS
kW/kW/kW/kW/kW db(A) db(A) kg m³/h m³/h / Pa mm kg V A A
Outdoors / White aluminium 55 °C / -20 °C -20 °C to 35 °C 7,60 / 2,90 9,10 / 3,40 10,90 / 4,10 12,00 / 4,60 2,65 63 33 2,50 2500 1.0 / 3000 1360 x 850 x 1360 219 230 1/N/PE~230V, 50Hz 38 25 Reverse cycle 1"
* The specified values have the following meaning, e.g. A+2/W35: heat source temperature +2 °C, heat outlet temperature 35 °C. ** Please note that additional space is required for pipe connections, operation and maintenance.
Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach
Page 1/4 Subject to change and errors! E-mail:
[email protected] Internet: www.dimplex.de
Internet: 25.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339
System accessories LA 11MS Description
Order ref.
Article number
Sample item
LA 11MS EVL 996-1 EVL 997-1 EVL 998-1
342420 321990 322000 322010
1 1
AS 976 SCHT 975-1 TUE 430 PSW 100 PSW 200 HCT 300 KPV 25 EB KPV UP 60 UP 80 DDV 32 VTB 25 WWM 25 MMH 25 MMB 25 HL 16SK
322180 322250 337430 351090 339830 351210 346590 348650 340300 340310 348450 339870 346600 348640 348880 351780
2 2 2
WWSP 332 WWSP 880 WWSP 900 PWS 332 CTHK 631 FLH 25M SVK 852 VTB 25 WWM 25 UP 60 UP 80 PWD 750
346610 337880 339220 348620 336180 349430 326660 339870 346600 340300 340310 349100
KRRV 003
322070
RBG WPM FWPM 470 RDS LDS LDS USB
339700 337470 353790 353770 353780
IN 01 WP
341750
Item
Price
Heat pumps Air-to-water heat pump with air deflection hoods Heat pump manager control line (10 m) Heat pump manager control line (20m) Heat pump manager control line (30m)
Hydraulic accessories 1" connecting hose (10 m) Hose nozzle for 1" / 1" connecting hose Nozzle for 1" connecting hose Floor-mounted buffer tank (100 l)* Floor-mounted buffer tank (200 l)* 3 kW radiator Compact manifold with overflow valve Differential pressureless manifold extension module Circulating pump for main heat pump circuit Circulating pump for main heat pump circuit Dual differential pressureless manifold* Manifold bar for connecting two heating circuits Unmixed heating circuit module* Mixed heating circuit with temperature sensor* Mixer module for bivalent systems Fan convector for heating/cooling with external thermostat*
1 1
DHW preparation accessories Hot water cylinder (300 l) with temperature sensor* Hot water cylinder (400 l) with temperature sensor* Hot water cylinder (500 l) with temperature sensor* Combination cylinder for heating and DHW preparation 2 kW immersion heater for back-up heating Flange heater for hot water cylinder 230 V/2.5 kW Safety valve combination Manifold bar for KPV 25 and HHM 25 connection Hot water module Circulating pump for main heat pump circuit Circulating pump for main heat pump circuit Combi cylinder for heating and domestic hot water preparation with central flow* Thermostat for heating and domestic hot water
1 1 1 1 1 1
Control accessories Swimming pool / remote fault indicator relay module Heat pump manager remote control* Remote diagnostics hardware package Remote diagnostics hardware package (serial) Remote diagnostics hardware package (USB)
Start-up (no discount available) Heat pump (heating only) start-up
1
* Other specific accessories available / required Important information: The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of the heat pump.
Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach
Page 2/4 Subject to change and errors! E-mail:
[email protected] Internet: www.dimplex.de
Internet: 25.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339
Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater SELECTED STEPS: 1. Air-to-water heat pump 2. Universal for customer-specific requirements 3. Heat pump and immersion heater 4. Overflow valve 5. 1 heating circuit for a panel or radiator heating system 6. Without cooling 7. DHW with heat pump and flange heating for thermal disinfection 8. Heat pump manager with external temperature control
Note: The given hydraulic integration schematic is a schematic representation of the key components and serves as an aid for planning your customized system. It does not contain all the required safety devices, the components needed to maintain constant pressure, or any other additional valves which may be required for maintenance and service work as stipulated by EN 12828. The heat pump manager settings and any external regulation system which may be connected must be adapted to the present integration diagram.
Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach
Page 3/4 Subject to change and errors! E-mail:
[email protected] Internet: www.dimplex.de
Internet: 25.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339
Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater Legend: 1. 1.1 1.2 1.3 1.4 1.5 1.6 2. 3. 3.1 4. 5. 6. 7. 8. 9. 10. 13.
Heat Pump Air-to-water heat pump Brine-to-water heat pump Water-to-water heat pump Reversible air-to-water heat pump Reversible brine-to-water heat pump Reversible water-to-water heat pump Heat pump manager Buffer tank Parallel buffer tank Hot water cylinder Swimming pool heat exchanger Passive cooling station with cooling controller N6 Heating and silent or dynamic cooling Fan convector with 4-wire connection Cooling circuit only Heating circuit only Heat source
Domestic hot water distribution system:
DDV 32 EB KPV KPV 25 MMB 25 MMH 25 SST 25 VTB 25 WWM 25
Dual differential pressureless manifold (up to 2.5 m³/h)* Extension module for compact manifold (up to 2.0 m³/h)* Compact manifold with overflow valve (up to 1.3 m³/h)* In combination with EB KPV (up to 2.0 m³/h)* Mixer module, bivalent (up to 2.0 m³/h)* Mixer module for heating circuit Solar station for hot water Manifold bar (up to 2.5 m³/h)* Hot water module / unmixed heating circuit (up to 2.5 m³/h)*
* Recommended max. heating waterflow
Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach
E9 E10 E10.1 E10.2 E10.3 E10.5 F7 K20 K21 M11 M12 M13 M14 M15 M16 M17 M18 M19 MA MZ N1 N2 N3/N4 N6 N12 R1 R2 R3 R4 R5 R9 R11 R13 TC Y5 Y6 Y7 Y8
Page 4/4 Subject to change and errors! E-mail:
[email protected] Internet: www.dimplex.de
Flange heater, hot water 2nd heat generator (HG2) Immersion heater Oil/gas boiler Solid fuel boiler Solar energy system Safety temperature monitor Contactor for 2nd heat generator Contactor for immersion heater hot water Primary pump for heating operation Primary pump for cooling operation Heat circulating pump for main circuit Heat circulating pump for heating circuit 1 Heat circulating pump for heating circuit 2 Auxiliary circulating pump Cooling circulating pump Hot water circulating pump Swimming pool water circulating pump Mixer open Mixer closed Heating controller Cooling controller for reversible heat pumps Room climate control stations Cooling controller for passive cooling Solar controller External wall sensor Return flow sensor Hot water sensor Return flow sensor for cooling water Temperature sensor for heating circuit 2 Flow sensor (antifreeze) Flow sensor for cooling water Sensor for heating circuit 3 / bivalent-renewable Room temperature controller Three-way distribution valve Two-way valve Three-way mixing valve Three-way valve (closing time max. 10 sec.)
Internet: 25.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339