La22hs

   EMBED


Share

Transcript

Data sheet LA 22HS High-temperature air-to-water heat pump Order reference: LA 22HS Installation location: Outdoors Flow temperature max 75 °C Casing, powder-coated High-temperature air-to-water heat pump for outdoor installation with outside temperature controlled heat pump controller (manager); sound-optimised through use of low-noise sickle-blade axial fans and air deflection hoods; stainless steel base frame; energy-efficient defrosting through cycle reversal and inclined evaporator; soft starter is integrated, return and outside temperature sensors are supplied with the unit. For hot water production in the summer, a flow temperature of 60°C is available. Electric connecting cable between heat pump and heat pump controller must be ordered separately. The heat pump complies with the valid standards and safety regulations as well as the Technical Specifications for Electrical Installations (TAB) of the electrical utility companies. Technical data LA 22HS Dimplex High-temperature air-to-water heat pump (High temperature) Order reference Set-up / Colour Temperature operating limits for heating water / Air Temperature operating limits for air Heat output / COP at A-7/W35* Heat output / COP at A+2/W35* Heat output / COP at A+7/W35* Heat output / COP at A+10/W35* Electrical nominal power consumption at A+2/W35 Sound pressure level at a distance of 10 m (air outlet side) Sound pressure level at a distance of 1 m (air outlet side) Refrigerant R404A / R134a Flow rate (heat source) Heating water flow rate with an int. pressure differential of Dimensions (W x D x H)** Weight (incl. packing) Control voltage Supply voltage Starting current with soft starter Fuse Defrosting / type of defrosting Device connections for heating LA 22HS kW/kW/kW/kW/kW db(A) Outdoors / White aluminium 75 °C / -20 °C -20 °C to 35 °C 11,00 / 2,60 13,60 / 3,10 15,40 / 3,40 16,50 / 3,50 4,00 41 db(A) 58 kg m³/h m³/h / Pa mm kg V A A 3,30 8000 1.8 / 3000 1680 x 1000 x 1710 411 230 3/PE~400V, 50 Hz 25 25 Reverse cycle 1 1/4" * The specified values have the following meaning, e.g. A+2/W35: heat source temperature +2 °C, heat outlet temperature 35 °C. ** Please note that additional space is required for pipe connections, operation and maintenance. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 1/4 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 25.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 System accessories LA 22HS Description Order ref. Article number Sample item LA 22HS EVL 996-1 EVL 997-1 EVL 998-1 340120 321990 322000 322010 1 AS 976-1 PSW 200 CTHK 631 CTHK 632 CTHK 633 CTHK 634 PSW 500 HDLR 450 KPV 25 EB KPV UP 60 UP 80 DDV 32 VTB 25 WWM 25 bauseits MMH 25 MMB 25 HL 16SK HL 26SK HL 36SK 330530 339830 336180 335910 322140 322150 339210 337450 346590 348650 340300 340310 348450 339870 346600 WWSP 880 FLH 60 FLHU 70 FLH 25M SVK 852 SST 25 WWSP 900 VTB 25 WWM 25 UP 80 PWD 750 337880 338060 338070 349430 326660 348430 339220 339870 346600 340310 349100 KRRV 003 322070 FG 3115 RBG WPM FWPM 470 RDS LDS LDS USB 336620 339700 337470 353790 353770 353780 IN 01 WP 341750 Item Price Heat pumps High-temperature air-to-water heat pump Heat pump manager control line (10 m) Heat pump manager control line (20m) Heat pump manager control line (30m) 1 Hydraulic accessories 1 1/4" connecting hose (10 m)* Floor-mounted buffer tank (200 l) 2 kW immersion heater for back-up heating 2.9 kW immersion heater for back-up heating 4.5 kW immersion heater for back-up heating 6 kW immersion heater for back-up heating Universal buffer tank (500 l)* Immersion heater pipe assembly* Compact manifold with overflow valve Differential pressureless manifold extension module Circulating pump for main heat pump circuit Circulating pump for main heat pump circuit Dual differential pressureless manifold* Manifold bar for connecting two heating circuits Unmixed heating circuit module Circulating pump depending on heating system pressure drop Mixed heating circuit with temperature sensor* Mixer module for bivalent systems Fan convector for heating/cooling with external thermostat* Fan convector for heating/cooling with external thermostat* Fan convector for heating/cooling with external thermostat* 1 1 1 1 1 348640 348880 351780 351790 351800 DHW preparation accessories Hot water cylinder (400 l) with temperature sensor 6 kW flange heater for hot water cylinder 2/2.7/4 kW flange heater for hot water cylinder Flange heater for hot water cylinder 230 V/2.5 kW Safety valve combination Solar station for hot water Hot water cylinder (500 l) with temperature sensor* Manifold bar for KPV 25 and HHM 25 connection Hot water module Circulating pump for main heat pump circuit Combi cylinder for heating and domestic hot water preparation with central flow* Thermostat for heating and domestic hot water 1 1 1 1 1 Control accessories External temperature sensor with casing Swimming pool / remote fault indicator relay module Heat pump manager remote control* Remote diagnostics hardware package Remote diagnostics hardware package (serial) Remote diagnostics hardware package (USB) Start-up (no discount available) Heat pump (heating only) start-up 1 * Other specific accessories available / required Important information: The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of the heat pump. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 2/4 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 25.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater SELECTED STEPS: 1. Air-to-water heat pump 2. Universal for customer-specific requirements 3. Heat pump and immersion heater 4. Differential pressureless manifold 5. 1 heating circuit for a panel or radiator heating system 6. Without cooling 7. DHW with heat pump and flange heating for thermal disinfection 8. Heat pump manager with external temperature control Note: The given hydraulic integration schematic is a schematic representation of the key components and serves as an aid for planning your customized system. It does not contain all the required safety devices, the components needed to maintain constant pressure, or any other additional valves which may be required for maintenance and service work as stipulated by EN 12828. The heat pump manager settings and any external regulation system which may be connected must be adapted to the present integration diagram. Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach Page 3/4 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Internet: 25.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339 Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater Legend: 1. 1.1 1.2 1.3 1.4 1.5 1.6 2. 3. 3.1 4. 5. 6. 7. 8. 9. 10. 13. Heat Pump Air-to-water heat pump Brine-to-water heat pump Water-to-water heat pump Reversible air-to-water heat pump Reversible brine-to-water heat pump Reversible water-to-water heat pump Heat pump manager Buffer tank Parallel buffer tank Hot water cylinder Swimming pool heat exchanger Passive cooling station with cooling controller N6 Heating and silent or dynamic cooling Fan convector with 4-wire connection Cooling circuit only Heating circuit only Heat source Domestic hot water distribution system: DDV 32 EB KPV KPV 25 MMB 25 MMH 25 SST 25 VTB 25 WWM 25 Dual differential pressureless manifold (up to 2.5 m³/h)* Extension module for compact manifold (up to 2.0 m³/h)* Compact manifold with overflow valve (up to 1.3 m³/h)* In combination with EB KPV (up to 2.0 m³/h)* Mixer module, bivalent (up to 2.0 m³/h)* Mixer module for heating circuit Solar station for hot water Manifold bar (up to 2.5 m³/h)* Hot water module / unmixed heating circuit (up to 2.5 m³/h)* * Recommended max. heating waterflow Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach E9 E10 E10.1 E10.2 E10.3 E10.5 F7 K20 K21 M11 M12 M13 M14 M15 M16 M17 M18 M19 MA MZ N1 N2 N3/N4 N6 N12 R1 R2 R3 R4 R5 R9 R11 R13 TC Y5 Y6 Y7 Y8 Page 4/4 Subject to change and errors! E-mail: [email protected] Internet: www.dimplex.de Flange heater, hot water 2nd heat generator (HG2) Immersion heater Oil/gas boiler Solid fuel boiler Solar energy system Safety temperature monitor Contactor for 2nd heat generator Contactor for immersion heater hot water Primary pump for heating operation Primary pump for cooling operation Heat circulating pump for main circuit Heat circulating pump for heating circuit 1 Heat circulating pump for heating circuit 2 Auxiliary circulating pump Cooling circulating pump Hot water circulating pump Swimming pool water circulating pump Mixer open Mixer closed Heating controller Cooling controller for reversible heat pumps Room climate control stations Cooling controller for passive cooling Solar controller External wall sensor Return flow sensor Hot water sensor Return flow sensor for cooling water Temperature sensor for heating circuit 2 Flow sensor (antifreeze) Flow sensor for cooling water Sensor for heating circuit 3 / bivalent-renewable Room temperature controller Three-way distribution valve Two-way valve Three-way mixing valve Three-way valve (closing time max. 10 sec.) Internet: 25.07.2007 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339