Preview only show first 10 pages with watermark. For full document please download

Labcold Rlhe1345

   EMBED


Share

Transcript

LABCOLD SUPERFREEZER MODEL RLHE1345 USERS INSTRUCTION MANUAL IMPORTANT PLEASE READ CAREFULLY THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE ESSENTIAL FOR THE RELIABLE OPERATION AND MAINTENANCE OF YOUR FREEZER 1 Important Notes: Please read carefully before installing your freezer. This Labcold product has been made with great care, tested thoroughly before being sent to you, and is expected to give good service over many years if looked after. The following information is provided for your guidance: 1. Acceptance: Immediately upon delivery to you the product packaging and the product itself should be inspected for any signs of damage. It was perfect when it left us and should still be so when you receive it. If this is not the case please contact the supplier from whom you ordered it within three days of delivery. 2. Positioning: Units should be positioned so as to allow adequate airflow around the refrigeration compartment. Once in its final position for use, the equipment must be left to stand for at least 2 hours before being switched on to prevent damage to the refrigeration system. 3. Stabilisation: Following the above resting period the equipment can be switched on and left for at least 24 hours to cool down and the temperature to stabilise. After this time the unit should be checked for correct operation. Only after this should the product be used for the storage of material. 4. Calibration: If desired, and following steps 1 to 3 above, the operating temperature inside the chamber (at the centre) may be checked against an independent thermometer of verified accuracy. Any adjustment necessary can then be made by reference to the appropriate section in this manual. All Labcold products have their operating temperatures factory set when being built but during transit, or when being operated in a different environment, small adjustments are sometimes necessary. Such adjustments are intended to be performed by the user and are not covered by the warranty. 5. Recalibration: For improved long term performance and security of contents the operation outlined in 4 above should be repeated at regular intervals. Labcold recommends once every six months. 6. Warranty: This Labcold product is warranted against manufacturing defect or malfunction for a period of 12 months from the date of delivery, or other time period as agreed in writing by the manufacturers. This warranty, valid within the United Kingdom only, covers all parts and all labour required to return the product to correct working order subject to the Standard Conditions of Sale provided it has been operated and cared for in accordance with this operators manual. If the product was purchased through a third party vendor, or outside the UK, then different terms may apply and reference should be made to the vendor from whom it was purchased. 7. Liability is limited to the extent of the Standard Conditions of Sale. Customers are advised that their rights to claim for damages lies with the vendor from whom the item was purchased. Labcold and its agents accept no further liability for the loss of customer’s stored samples, products or other contents, nor the direct or indirect economic or other consequences resulting from such loss. Customers are therefore advised to ensure that they establish suitable checking and monitoring protocols as appropriate to the importance and risk associated with the stored contents in order to mitigate any loss that may occur. Customers are further advised to ensure that they have a suitable contingency plan in place to safeguard their stored property in the event that the unit cannot be repaired in time to prevent its loss or spoilage. 8. Customers are advised to read this manual together with the vendor’s Standard Terms and Conditions of Sale to which this product, its use, delivery and installation, repair, and warranty are subject. A copy of the Standard Terms and Conditions of Sale may be obtained by contacting the vendor or viewing their catalogue or web site. 2 OPERATING INSTRUCTIONS FOR LABCOLD SUPERFREEZER MODEL RLHE1345 This freezer has been designed for reliability, efficiency of operation and long life. A little care with its sitting and use will be amply rewarded. POSITION The freezer should be positioned on a solid level floor allowing an air space of 75mm around it. This air space is required to dissipate the heat, which is extracted from the chamber. If the freezer has been tipped during positioning, it should be left to stand for 24 hours prior to switching on. The freezer should be sited in a position that is as cool and well ventilated as practical and out of direct sunlight. SERVICES The freezer is best connected to an individual fused spur protected by a 13 amp fuse. Connection can also be made through a suitable plug again fused at 13 amps. A removable plug adds to the chance of accidental disconnection of the equipment. If the electric supply has an RCD fitted, it must be of a value of at least 70mA to avoid nuisance trips. If the remote alarm connections are required they are found on the rear of the freezer. The contacts are clearly labelled and are rated up to a maximum of 500mA at 24V D.C. DISPLAY ELECTRONIC THERMOMETER WITH TEMPERATURE ALARM Labelling enhanced for instruction purposes BUTTON FUNCTION & RECORD VALUES MAX/ MIN RECORD VALUES button. The display will show To see the maximum recorded temperature, press and then the maximum recorded temperature will be displayed. To see the minimum recorded temperature, press button. The display will show and then the minimum recorded temperature will be displayed. 3 RESET RECORD VALUES To reset the maximum recorded temperature, press button. Then hold the button . The maximum recorded temperature is now for 3 seconds until the display shows reset. To reset the minimum recorded temperature, press 3 seconds until the display shows button. Then hold the button for . The minimum recorded temperature is now reset. CHANGE SET POINT VALUE To change the set point value press and hold the or button for 3 seconds. Then use the button to change the value. ALARM SETTINGS PRESS ANY OF THE BUTTONS TO MUTE THE ALARM The Alarm settings for this refrigerator when set to run at -40oC are:HIGH ALARM: SET POINT -30ºC LOW ALARM: SET POINT -50ºC ALARM DELAY: 15 MINS REMOTE ALARM CONNECTIONS (OPTIONAL EXTRA) The remote volt free contacts can be found on the rear of the freezer labelled “REMOTE ALARM” N/C, N/O, COMMON”. These contacts can be connected to any alarm system or telephone dialling unit that operates on low voltage. Do not connect to Mains (240V) equipment. Maximum rating 30V, 2.50mA. ! WARNING ! The interior of this unit will cause freezer burn to unprotected skin when operating. We recommend the use of high efficiency asbestos free gloves. Cryo-Gloves are ideal for this purpose and for use with ovens and autoclaves. Filing systems improve the efficiency with which the chamber can be used. They repair their cost in time saving within a short period. If you have any queries regarding this freezer do not hesitate to call our Service Department 0870 300 1002 WEEE: Disposal at end of life. This equipment, when being disposed of in an EU Member State, is subject to the Waste Electrical and Electronic Equipment Regulations (WEEE) and must be recycled and disposed of in accordance with EU directive 2002/96/EC as applied in local laws of that State at the time of disposal. As this item is designed for medical or scientific use, before presenting for collection and disposal it will be necessary for the user to provide documentary evidence of decontamination and/or that it is entirely safe to handle and dismantle outside of a controlled environment. Goods that cannot be so certified fall outside the scope of the Directive and remain the user's responsibility to dispose of. Labcold recognises the benefit to the environment of this legislation and is designing products to allow more recycling and less impact on landfill. Please contact your vendor or local Labcold distributor for further advice on disposal of this product at the end of its useful life. LABCOLD, The Loddon Centre, Wade Road, Basingstoke, Hampshire, RG24 8FL 4