Preview only show first 10 pages with watermark. For full document please download

Labcompanion_temperaturechambers

   EMBED


Share

Transcript

Temperature Chambers SELECTION GUIDE Temperature Chambers Temperature Chambers (Floor Standing Models) Temperature Chambers (Tabletop Models) Operating Temp. Range (℃/℉) Description TC-G-180 180 / 6.4 TC-G-300 300 / 10.6 TC-G-408 Temperature Chambers (Floor Standing Models) TC-G-800 -35 to 150 / -31 to 302 TC-G-1500 1500 / 53 TC-KE-065 148 - 153 300 / 10.6 25 / 0.9 TC-KE-025 (Tabletop Models) 800 / 28.3 1000 / 35.3 -60 to 150 / -76 to 302 Page 408 / 14.4 TC-G-1000 TC-GU-300 Temperature Chambers Chamber Volume (L / cu ft) -35 to 150 / -31 to 302 65 / 2.3 TC-KE-100 100 / 3.53 TC-ME-025 25 / 0.9 154 - 159 TC-ME-065 -20 to 120 / -4 to 248 TC-ME-100 65 / 2.3 100 / 3.53 Accessories & Options Description for Temperature Chambers Page 160-161 GENERAL APPLICATIONS Temperature Chambers Test for reliability, durability, climatic, freezing resistance, quality assurance, thermal endurance etc. - Testing for electric and electronic component, sensors. - Testing for semiconductor, PCB, LCD & LED. - Pharmaceutical tests. - Mechanical / Military / Aircraft engineering. - Automobile, Transport / automobile supply industries. - Chemical / Petrochemical industries. - Construction materials / Plastic / Textile industries. - Testing mould, liquor, cigar, paintings. - Testing metal related industries like plating etc. TECHNICAL BENEFITS Safety Features 1) Self-protecting cut-off function: - Over temperature, electrical leakage or over voltage automatically cuts the power from the unit, in an orderly fashion, starting with the heating element then the controller unit. 2) T  ime setting function for automated RUN / OFF: - Enable automatic start and shut off of a unit at any specific time. - A timer can be set for a month and data can be recorded in time, day, or week intervals. 3) Door-open warning alarm: - Intermittent toned alarm audible alarm and visual alarms. - Heating element, fan, and platform automatically stops when the door is opened to minimize heat loss and to ensure users safety. Optimum Control Features 1) Microprocess PID control / Auto-tuning / Calibration. 2) Optimize CPU logic control system. - Optimum control of temperature with economical controls that reduces power consumption. 3) Touch screen type display. - 5.7-inch Color LCD display with interactive input system. ( Floor Standing Models only) -T  emperature / timer settings, and operation condition. - Temp., other operating parameters can be recorded using a chart recorder. - Easily visible set value: set point (SP) / pre-sent value (PV) are also added on the colorful LCD controller. Protect the Global Environment - Use of HFC refrigerant prevents damage to the ozone layer. -C  omplies with the Montreal Protocol on Substances That Deplete the Ozone Layer control measures. T Temperature Chambers Temperature Chambers (Floor Standing Models) Certification only for the TC-G-180·300·408 Floor Standing Models TC-G / GU Models 148 Temperature Chambers Temperature Chambers (Floor Standing Models) Dimension (TC-G / GU Models) Models TC-G TC-GU Capacity 180L (6.4cu ft) 300L (10.6cu ft) 408L (14.4cu ft) 800L (28.3cu ft) 1000L (35.3cu ft) 1500L (53 cu ft) 300L (10.6cu ft) W 1025mm (40.4”) 1120mm (44.1”) 1120mm (44.1”) 1570mm (61.8”) 1570mm (61.8”) 1570mm (61.8”) 1120mm (44.1”) D H 1035mm (40.7”) 1070mm (42.1”) 1240mm (48.8”) 1245mm (48.8”) 1445mm (56.9”) 2045mm (80.5”) 1070mm (42.1”) 1530mm (60.2”) 1730mm (68.1”) 1730mm (68.1”) 2060mm (81.1”) 2060mm (81.1”) 2050mm (80.7”) 1730mm (68.1”) A 450mm (17.7”) 450mm (17.7”) 520mm (20.5”) 490mm (19.3”) 560mm (22”) 560mm (22”) 450mm (17.7”) B 1230mm (48.4”) 1230mm (48.4”) 1230mm (48.4”) 1260mm (49.6”) 1260mm (49.6”) 800mm (31.5”) 1230mm (48.4”) Air Flow & Operating Range TC-G Models • -35℃ to 150℃ / -31℉ to 150℉ TC-GU Models • -60℃ to 150℃ / -76℉ to 302℉ 149 T Temperature Chambers Temperature Chambers (Floor Standing Models) Operating & Constructional Features Constructional Features Door Catch & Trim • Standard environmental test chambers. • High quality #304 stainless steel exterior and interior. • Casters for easy mobility when installing or moving temp. test chamber. •C  onvenient maintenance-available to view total operating time. • Spacious chamber volume maximum capacity of 1500L. • Choose from 7 different model chambers based on size and temperature preference. - The series comes in 2 different models based on temp. ranges ranging in -35℃ to 150℃, -60℃ to 150℃ and six different volume capacities of 180L, 300L, 408L, 800L, 1000L and 1500L. • Unique door lock & trim. - Vice lock type door and foam silicone packing to ensure a perfect seal. - Door open warning alarm. • Inner door. - Optional inner glass door comes with four holes to handle samples inside the chamber. (excludes chambers with volume capacities of 800L or 1500L) • Ventilation. - Ventilation vent is located at the upper right side of the unit. • Chart recorder. (optional) - 6-point dot type recorder with a digital display. • Viewing window for observation. - Tempered glass window provides a clear view of samples in the chamber, beneficial during testing. - Fluorescent lighting source included. • Cable port for external probes or wires. - 50mm diameter cable port comes standard on the left side of the unit. Additional 50mm or 80mm diameter cable ports can be custom ordered. (optional) • Easy cleaning of condenser air-filter. - To prevent deterioration of refrigeration system and keep filter dust free by periodically cleaning the filter. Color LCD Controller ℃ 25.0 ℃ 100.0 Digital Recorder (optional) 150 Safety Features • Leakage breaker for power supply. • Over current protection. • Overheat / overcool protection. • Switch-off after alarm for over heating. • Door open alarm. • Vice lock door type locking mechanism. Temperature Chambers Temperature Chambers (Floor Standing Models) Operating Features • Microprocess PID control / Auto-tuning / Calibration. •C  hamber supports three different languages: English, Chinese, and Korean. • Optimize CPU logic control system. - Optimum control of temperature with economical power consumption. • Touch screen type display. - 5.7-inch Color LCD display with interactive input system. : Easily visible set value: set point (SP) /present value (PV) are also added on the colorful LCD controller. - Temperature, timer settings, operation condition. - Temperature and other operating parameters can be recorded using a chart recorder. • Programming operation. Description TC-G / GU Programmable Pattern Capacity Pattern Repeat Time Max. Segments per a Pattern Available Max. Segments* Programmable Process Time per a Segment 120 999 100 1200 0 to 99 hr 59 min Viewing Window Cable Port * Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment an patterns properly. • Computer interface. - Save data in excel format. - Software provided. - Storage of program information, backup of value settings / recovery, and temperature values. - RS-232C port as standard offer. •R  S-485 communication port offers connection of a maximum of 9 temperature chamber units to one PC. (optional) Multi-control Display Single-control Display Program Setting Display Graph Display Air Filter Ventilation 151 T Temperature Chambers Temperature Chambers (Floor Standing Models) Specifications & Ordering Information Model Chamber Volume (L / cu ft) TC-G-180 TC-G-300 180 / 6.4 300 / 10.6 TC-G-408 0.2 / 0.36 at 100℃ (±℃ / ℉) at 100℃ (±℃ / ℉) 0.9 / 1.62 1 / 1.80 0.8 / 1.44 Mechanical single stage refrigerator system R-404A Capacity (W) 1500 (68℉ to -31℉) (air-cooled condenser) R-404A (1st step), R-23 (2nd step) 4250 6000 Plate fin cooler Ni-Cr Wire Heater Material SUS TUBE Heater 2000 Drying Bulb (W) 3000 5000 Pt 100 Temperature Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94”) Door Glass wool Tangent blower (90W) 4 sets of sirocco fan (4×90W) Interior (mm / inch) 500×630×600 / 19.7×24.8×23.6 600×630×800 / 23.6×24.8×31.5 600×850×800 / 23.6×33.5×31.5 1000×800×1000 / 39.4×31.5×39.4 1000×1000×1000 / 39.4×39.4×39.4 1000×1000×1500 / 39.4×39.4×59.1 Exterior (mm / inch) 1025×1035×1530 / 40.4×40.7×60.2 1120×1070×1730 / 44.1×42.1×68.1 1120×1240×1730 / 44.1×44.8×68.1 1570×1245×2060 / 61.8×49×81.1 1570×1445×2060 / 61.8×56.9×81.1 1570×2045×2560 / 61.8×80.5×81.1 Viewing Windows Net Weight (kg / lbs) 200×330 / 7.9×13 310±10 / 683.4±22 375±10 / 826.7±22 270×330 / 10.6×13 400±10 / 881.8±22 Cable Port Basically one hole provided / Ø50mm (2”) Optionally max. two holes available / Ø50 or 80mm (2 or 3.2”) Interface Port Basically RS-232C [RS-485(Maximum 9 Units Control)-optional] 1ph / 16.2A Electrical Requirements (230V, 60Hz) Cat. No. AAH81411K Cat. No. AAH81412K AAH81422K AAH81419K AAH81429K AAH81418K AAH81428K 670±10 / 1477±22 AAH81441K AAH81451K 3ph / 22.5A AAH81432K AAH81442K AAH81452K 3ph / 11.5A AAH81439K 3ph / 5.2A Electrical Requirements (380V, 50Hz) 610±10 / 1345±22 3ph / 22.5A AAH81431K 3ph / 5.4A Electrical Requirements (380V, 60Hz) Cat. No. AAH81421K 1ph / 16.2A Electrical Requirements (230V, 50Hz) AAH81449K AAH81459K 3ph / 11.5A AAH81438K 1) Technical data according to DIN 12880, IEC 60068. ※  Certification only for the TC-G-180∙300∙408. ※ Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%). ※ All specifications are under ambient temperature 20℃ (68℉), No Load. 152 85 From 20℃ to -35℃ Mechanical dual stage refrigerator system (air-cooled condenser) (mm / inch) Cat. No. 0.5 / 0.9 On singe point control Refrigerant Air Flow (W×D×H) 0.5 / 0.9 60 From -35℃ to 120℃ (-31℉ to 248℉) Cooler Dimension 0.4 / 0.72 60 From 20℃ to -35℃ (68℉ to -31℉) Cooling (Min.) System 0.1 / 0.18 50 From -35℃ to 120℃ (-31℉ to 248℉) Heating (Min.) Time Material TC-G-1500 1500 / 53 -35 to 150 / -31 to 302 Fluctuation 1) Variation 1) Sensor 1000 / 35.3 Cooling fuzzy control system Range (℃ / ℉) Heater TC-G-1000 800 / 28.3 Programmable, Touch screen type controller (5.7” Color monitor) Controller Refrigeration TC-G-800 408 / 14.4 Control System Temperature Certification only for the TC-G-180.300.408 AAH81448K AAH81458K 750±10 / 1653.5±22 3ph / 28.5A AAH81462K 3ph / 15.2A AAH81468K Temperature Chambers Temperature Chambers (Floor Standing Models) Specifications & Ordering Information Model TC-GU-300 300 / 10.6 Chamber Volume (L / cu ft) Cooling fuzzy control system Control System Programmable, Touch screen type controller (5.7” Color monitor) Controller Range (℃ / ℉) Temperature -60 to 150 / -76 to 302 ­without humidity *best programmable control range : -50 to 140 / -58 to 284 0.3 / 0.54 Fluctuation 1) at 40℃ (±℃ / ℉) 0.5 / 0.9 Variation 1) at 40℃ (±℃ / ℉) Time Heating (Min.) Cooling (Min.) System Refrigeration Refrigerant 60 From -60℃ to 120℃ (-76℉ to 248℉) 65 From 20℃ to -60℃ (68℉ to -76℉) on singe point control Mechanical single stage refrigerator system (air-cooled condenser) R-404A (1st step), R-23 (2nd step) 3000 Capacity (W) Plate fin cooler Cooler Heater Material Ni-Cr Wire Heater 2000 Drying Bulb (W) Pt 100 Temperature Sensor Interior Material Exterior Insulation Stainless steel #304 Stainless steel #304 Polyurethane foam 100mm (3.94”) Glass wool Door Tangent blower (90W) Air Flow Dimension (W×D×H) Interior (mm / inch) 600×630×800 / 23.6×24.8×31.5 Exterior (mm / inch) 1120×1070×1730 / 44.1×42.1×68.1 Viewing Windows (mm / inch) Net Weight (kg / lbs) Cable Port Interface Port 200×330 / 7.9×13 375±10 / 870.8±22 Basically one hole provided / Ø 50mm (2”) Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”) Basically RS-232C [RS-485(Maximum 9 Units Control)-optional] Electrical Requirements (230V, 60Hz) 1ph / 24.3A Cat. No. AAH81521K Electrical Requirements (230V, 50Hz) 1ph / 24.3A Cat. No. AAH81522K Electrical Requirements (380V, 60 / 50Hz) Cat. No. 3ph / 8.3A AAH81528K 1) Technical data according to DIN 12880, IEC 60068. ※ Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%). ※ All specifications are under ambient Temperature 20℃ (68℉), No Load. 153 T Please visit Temperature Chambers Temperature Chambers (Tabletop Models) .com For further information on Jeio Tech´s Temperature Chamber products Information is readily available on our website. TC-KE-100 TC-ME-100 with stand (optional) ※ In the year of 2012, this products design can be changed without prior notice. 154 Temperature Chambers Temperature Chambers (Tabletop Models) Dimension (TC-KE / ME Models) Models TC-KE TC-ME Capacity 25L (0.9cu ft) 65L (2.3cu ft) 100L (3.53cu ft) 25L (0.9 cu ft) 65L (2.3 cu ft) 100L (3.53 cu ft) W 520mm (20.5”) 570mm (22.4”) 650mm (25.6”) 610mm (24”) 660mm (26”) 760mm (29.9”) D 760mm (29.9”) 890mm (35”) 1000mm (39.4”) 855mm (33.7”) 970mm (38.2”) 1070mm (42.1”) H 867mm (34.1”) 1010mm (39.8”) 1050mm (41.3”) 920mm (36.2”) 1065mm (41.9”) 1085mm (42.7”) A 200mm (7.9”) 235mm (9.3”) 263mm (10.4”) 220mm (8.7”) 258mm (10.2”) 318mm (12.5”) B 467mm (18.4”) 540mm (21.2”) 557mm (21.9”) 498mm (19.6”) 570mm (22.4”) 56.3mm (22.2”) Air Flow & Operating Range TC-KE Models • -35℃ to 150℃ / -31℉ to 302℉ TC-ME Models • -20℃ to 120℃ / -4℉ to 248℉ 155 T Temperature Chambers Temperature Chambers (Tabletop Models) Operating & Constructional Features Constructional Features • Small size and light weight. • Compact design with high performance. • Choose from 6 different model chambers based on size and temperature preference. - The series comes in 2 different model based on temp. ranging in -35℃ to 150℃, -20℃ to 120℃ and three different volume capacities of 20L, 65L, 100L. • Efficient system with durable materials. - The evaporating system for better thermal efficiency with corrosion-resistant materials. - The heating system with minimized potential heat when heating or cooling for prompt reaction time and advanced performance. • Viewing window. - A tempered glass window provides a clear view of samples in the chamber, beneficial during testing. • Cable port for external probes or wires. - 50mm diameter cable port comes standard on the left side of the unit. Additional 50mm or 80mm diameter cable ports can be custom ordered. (optional) • Optional stand for space-saving layout. - For use in limited spaces: stand and casters. ※ Be sure to secure the stand onto floor with earthquake resistant fitting for your safety when using stand. Inner Glass Door Safety Features Controller Portable Recorder (optional) 156 • Leakage breaker for power supply. • Over current protection. • Overheat protection. • Switch-off after alarm for over heating. • Door open alarm. Temperature Chambers Temperature Chambers (Tabletop Models) Operating Features • Microprocessor PID control / Auto-tuning / Calibration. • Digital LCD display with touch-sensitive keys. • Easy operation with wide LCD screen. -T  emperature / timer settings and operating condition. • Program patterns are memorized for 10 years due to a battery built into the PCB. • Expansion parameter inputs. (displayed by letters) • Programming operation. Description Programmable Pattern Capacity TC - KE / ME 10 Pattern Repeat Time 999 Max. Segments per a Pattern 100 Available Max. Segments* Programmable Process Time per a Segment 100 Door Handle (TC-KE Models only) 0 to 99 hr 59 min * Even though the max. segments per a pattern are 100, available total segments are up to 300 not 3000, so you need to arrange the number of segment and patterns properly. • Computer interface. (optional) - Software provided. - Save data in excel format. - Storage of program information, backup of value settings / recovery, and temperature values. - RS-232C port as standard offer. • Chart Recorder. (optional) - 6 point dot type recorder with digital display. • RS-485 communication port offers a maximum of 9 temp. chambers to be connected by one PC. (optional) Multi-control Display Single-control Display Program Setting Display Graph Display Water Tank Cable Port 157 T Temperature Chambers Temperature Chambers (Tabletop Models) Specifications & Ordering Information Model TC-KE-025 25 / 0.9 Chamber Volume (L / cu ft) TC-KE-065 65 / 2.3 PID control (LCD Type) Controller -35~150 / -31~302 Range (℃ / ℉) Temperature1) TC-KE-100 100 / 3.53 ± 0.5°C Fluctuation2) at 50℃ (±℃ / ℉) Variation2) at 50℃ ± 1°C (±℃ / ℉) Heating 60 (-40℃  100℃) Cooling3) 70 (25℃  -35℃) System Mechanical single stage refrigerator system (air-cooled condenser) Refrigerant R-404A Capacity (W) 470 3) Time Refrigeration Heater Material Ni-Cr Wire Heater Drying Bulb (W) 1000 Temperature Sensor Material 565 657 1200 1500 Plate fin cooler (cooper) Cooler Pt 100 Internal Stainless steel #304 (2B polish) External Stainless steel #304 & Steel, 0.8t, Double painted & baked Insulation Polyurethane foam 100mm [3.94”] Door Glasswool Air Flow (sirocco fan) 60W×1EA Interface Port Basically RS-232C, [RS-485:optional] Cable Port Basically one hole provided / Ø50mm (2”) Optionally max. two holes available / Ø50 or 80mm (2 or 3.2”) Dimension (W×D×H) Electrical Requirements 60W×1EA Internal (mm / inch) 350×220×350 / 13.8×8.7×13.8 400×330×495 / 15.7×13×19.5 500×380×530 / 19.7×15×20.9 External (mm / inch) 610×855×920 / 24×33.7×36.2 660×970×1065 / 26×38.2×41.9 760×1070×1085 / 29.9×42.1×42.7 Weight (kg / lbs) 110 ±10 / 242.5 ±22 140 ±10 / 308.6 ±22 150 ±10 / 330.7 ±22 7.4A 8.8A 10.8A AAH86111K AAH86121K AAH86131K 7.1A 8.4A 10.3A AAH86112K AAH86122K AAH86132K AC230V, 1ph, 60Hz AC230V, 1ph, 50Hz 1) All specifications are under ambient temperature 20℃ (68℉), no load. 2)Technical data according to DIN 12880, IEC 60068. 3) Up to 98% of the set value. * 80mm cable access hole is NOT available for 25L chamber (TC-ME-025). * Above the dimensions are NOT included size of attached accessories. ※Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%).  Recommended ambient temperature : +20℃ (68℉). 158 60W×2EA Temperature Chambers Temperature Chambers (Tabletop Models) Specifications & Ordering Information Model TC-ME-025 25 / 0.9 Chamber Volume (L / cu ft) Program controller (LCD type) Controller Range (℃ / ℉) -20 to 120 / -4 to 248 Program Control (℃ / ℉) -15 to 120 / -5 to 248 Fluctuation 1) (±℃ / ℉) at 100℃ 0.4 / 0.72 0.3 / 0.55 0.3 / 0.55 Variation  (±℃ / ℉) at 100℃ 2 / 3.60 1.9 / 3.42 1.8 / 3.24 1) Time Heating (Min.) 55 From -15℃ to 120℃ (5℉ to 248℉) Cooling (Min.) 60 From 20℃ to -15℃ (68℉ to 5℉) on singe point control * Mechanical single stage refrigerator system (air-cooled condenser) System Refrigeration R-404A Refrigerant 250 Capacity (W) 250 Ni-Cr Wire Heater Material 800 Drying Bulb (W) 1000 Interior Stainless steel #304 Exterior Stainless steel, 1mm (0.04”) / Double painted & baked Polyurethane foam 50mm (1.97”) Insulation Glass wool Door Sirocco fan (60W) Air Flow Dimension (W×D×H) Interior (mm / inch) 350×220×350 / 13.8×8.7×13.8 400×330×495 / 15.7×13×19.5 500×380×530 / 19.7×15×20.9 Exterior (mm / inch) 500×760×850 / 19.7×29.9×33.5 550×890×1000 / 21.7×35×39.4 650×1000×1030 / 25.6×39.4×40.6 Net Weight (kg / lbs) 80±5 / 176±11 110±5 / 242±11 130±5 / 286±11 Basically one hole provided / Ø 50mm (2”) Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”) Cable Port Basically RS-232C [RS-485 (Maximum 9 Units Control) - optional] Interface Port Electrical Requirements 1000 Pt 100 Temperature Sensor Material 375 Plate fin cooler (cooper) Cooler Heater TC-ME-100 100 / 3.53 Cooling PID control system Control System Temperature TC-ME-065 65 / 2.3 AC230V, 1ph, 60Hz AC230V, 1ph, 50Hz 5.3A 6.1A 6.8A AAH86011K AAH86021K AAH86031K 5.1A 6A 6.5A AAH86012K AAH86022K AAH86032K 1)Technical data according to DIN 12880, IEC 60068. * 80mm cable access hole is NOT available for 25L chamber (TC-ME-025). * Above the dimensions are NOT included size of attached accessories. ※ Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%). ※ All specifications are under ambient temperature 20℃ (68℉), no load. 159 T Temperature Chambers Accessories & Options Viewing Window Inner Door Recorder Viewing Window Warning Signal Light Cable Port • An observation window is only installed in the floor type chambers. • A tempered dual window provides a clear view of samples during testing. • A through hole of 50 or 80mm dia. (2.0 or 3.2˝ dia.) is provided on the wall of chamber to allow electrical cables to be introduced into the chamber. A 50mm hole is provided, maximum two holes (50 or 80mm) are optional. Inner Door Shelf •A  n inner glass door for quick viewing of samples and to prevent outside air from flowing in. (Table top - without hand entry ports.) Temperature Recorder • 6-point dot type recorder. • digital display. •W  ire and perforated type shelves (shelf brackets included) are made of durable stainless steel. Standard shelves and shelf brackets come standard. Warning Signal Light • A malfunction indicator can be placed on the right upper side. Tabletop Chambers Cat. No. AAA8T504 AAA8T506 AAA8T540 AAA8T541 AAA8T542 AAA80550 RTD679 RTD680 RTD681 AAA80602-6 AAA80602-7 AAA80602-8 AAA8T612 AAA8T613 AAA8T610 AAA8T611 AAA80631 AAA80632 AAA80633 AAA80634 AAA80635 CFA1910 Description 25L Portable Recorder (6 points) Portable Recorder (digital, 6 channels) RS-232C Interface Converter included a Cable (5m / 16.4ft) RS-485 Interface Converter included a Cable (5m / 16.4ft) Interface Cable (5m / 16.4ft) Warning Signal Lamp Wire Shelf for TC - KE / ME - 025 Wire Shelf for TC - KE / ME - 065 Wire Shelf for TC - KE / ME - 100 Perforated Shelf for TC - KE / ME - 025 Perforated Shelf for TC - KE / ME - 065 Perforated Shelf for TC - KE / ME - 100 Cable Port (Ø 50mm / 2.0”) for TC - ME Models Cable Port (Ø 80mm / 3.2”) for TC - ME Models Cable Port (Ø 50mm / 2.0”) for TC - KE Models Cable Port (Ø 80mm / 3.2”) for TC - KE Models Stand for TC - KE / ME - 025 Stand for TC - KE / ME - 065 Stand for TC - KE / ME - 100 Two Step Stand for TC - KE / ME - 025 Two Step Stand for TC - KE / ME - 065 Temperature Sensor (RTD type) • • • • • • • • • • • • • TC-KE 65L • • • • • • • • • • • • • 100L • • • • • • • • • • • • 25L • • • • • • • • • • • • • TC-ME 65L • • • • • • • • • • • • • ※ 80mm cable access hole is NOT available for 25L chamber. Wire & Perforated Shelves for Tabletop Chambers Models TC - KE / ME - 025 TC - KE / ME - 065 TC - KE / ME - 100 * Only for wire shelf. 160 Included* 2 2 2 Maximum 7 10 10 Description Space 20mm (0.8”) 20mm (0.8”) 20mm (0.8”) Dimension (W×L) 195×310mm (7.7×12.2”) 280×360mm (11×14.2”) 330×460mm (13×18.1”) 100L • • • • • • • • • • • • Temperature Chambers Accessories & Options Floor Standing Chambers Cat. No. Description Recorder (6 points) Recorder (digital, 6 channels) RS-485 Interface Converter included a Cable (5m / 16.4ft) Interface Cable (5m / 16.4ft) Warning Signal lamp Inner Glass Door (only for 180L chambers) Inner Glass Door (only for 270, 300, 408L chambers) Wire Shelf for TC - G - 180 Wire Shelf for TC - G/GU - 300 Wire Shelf for TC - G - 408 Wire Shelf for TC - G - 800 Wire Shelf for TC - G - 1000, 1500 Perforated Shelf for TC - G - 180 Perforated Shelf for TC - G/GU - 300 Perforated Shelf for TC - G - 408 Perforated Shelf for TC - G - 800 Perforated Shelf for TC - G - 1000 , 1500 Cable Port (Ø 50mm / 2.0”) Cable Port (Ø 80mm / 3.2”) Temperature Sensor (RTD type) AAA8T500 AAA8T505 AAA8T541 AAA8T542 AAA80550 AAA81552 AAA81551 EDA8212 EDA8213 EDA8214 EDA8215 EDA8216 AAA80602-1 AAA80602-2 AAA80602-3 AAA80602-4 AAA80602-5 AAA8T610 AAA8T611 CFA1185 180L 300L • • • • • • • • • • • • • • • • • • • • • • • • TC-G 408L • • • • • • • • • • • • 800L • • • • • • • • • • • • 1000L 1500L • • • • • • • • • • • • • • • • • • • • • • • • Wire & Perforated Shelves for Floor Standing Chambers Models TC - G - 180 TC - G/GU - 300 TC - G - 408 TC - G - 800 TC - G - 1000, 1500 Included* 2 2 2 2 2 Maximum 9 10 10 14 14 Description Space 40mm (1.6”) 40mm (1.6”) 40mm (1.6”) 40mm (1.6”) 40mm (1.6”) Dimensions (W×L) 463×518mm (17.2×20.4”) 518×558mm (20.4×22.0”) 560×740mm (22.0×29.1”) 750×960mm (30.0×37.8”) 950×960mm (37.4×37.8”) * Only for wire shelf. ※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details. 161