Transcript
Temperature Chambers SELECTION GUIDE
Temperature Chambers
Temperature Chambers (Floor Standing Models)
Temperature Chambers (Tabletop Models)
Operating Temp. Range (℃/℉)
Description TC-G-180
180 / 6.4
TC-G-300
300 / 10.6
TC-G-408 Temperature Chambers (Floor Standing Models)
TC-G-800
-35 to 150 / -31 to 302
TC-G-1500
1500 / 53
TC-KE-065
148 - 153
300 / 10.6 25 / 0.9
TC-KE-025
(Tabletop Models)
800 / 28.3 1000 / 35.3
-60 to 150 / -76 to 302
Page
408 / 14.4
TC-G-1000
TC-GU-300
Temperature Chambers
Chamber Volume (L / cu ft)
-35 to 150 / -31 to 302
65 / 2.3
TC-KE-100
100 / 3.53
TC-ME-025
25 / 0.9
154 - 159
TC-ME-065
-20 to 120 / -4 to 248
TC-ME-100
65 / 2.3 100 / 3.53
Accessories & Options Description for Temperature Chambers
Page 160-161
GENERAL APPLICATIONS Temperature Chambers Test for reliability, durability, climatic, freezing resistance, quality assurance, thermal endurance etc.
- Testing for electric and electronic component, sensors.
- Testing for semiconductor, PCB, LCD & LED.
- Pharmaceutical tests.
- Mechanical / Military / Aircraft engineering.
- Automobile, Transport / automobile supply industries.
- Chemical / Petrochemical industries.
- Construction materials / Plastic / Textile industries.
- Testing mould, liquor, cigar, paintings.
- Testing metal related industries like plating etc.
TECHNICAL BENEFITS Safety Features 1) Self-protecting cut-off function: - Over temperature, electrical leakage or over voltage automatically cuts the power from the unit, in an orderly fashion, starting with the heating element then the controller unit. 2) T ime setting function for automated RUN / OFF: - Enable automatic start and shut off of a unit at any specific time. - A timer can be set for a month and data can be recorded in time, day, or week intervals. 3) Door-open warning alarm: - Intermittent toned alarm audible alarm and visual alarms. - Heating element, fan, and platform automatically stops when the door is opened to minimize heat loss and to ensure users safety.
Optimum Control Features 1) Microprocess PID control / Auto-tuning / Calibration. 2) Optimize CPU logic control system. - Optimum control of temperature with economical controls that reduces power consumption. 3) Touch screen type display. - 5.7-inch Color LCD display with interactive input system. ( Floor Standing Models only) -T emperature / timer settings, and operation condition. - Temp., other operating parameters can be recorded using a chart recorder. - Easily visible set value: set point (SP) / pre-sent value (PV) are also added on the colorful LCD controller.
Protect the Global Environment - Use of HFC refrigerant prevents damage to the ozone layer. -C omplies with the Montreal Protocol on Substances That Deplete the Ozone Layer control measures.
T
Temperature Chambers
Temperature Chambers (Floor Standing Models)
Certification only for the TC-G-180·300·408
Floor Standing Models
TC-G / GU Models
148
Temperature Chambers
Temperature Chambers (Floor Standing Models)
Dimension (TC-G / GU Models)
Models
TC-G
TC-GU
Capacity 180L (6.4cu ft) 300L (10.6cu ft) 408L (14.4cu ft) 800L (28.3cu ft) 1000L (35.3cu ft) 1500L (53 cu ft) 300L (10.6cu ft)
W 1025mm (40.4”) 1120mm (44.1”) 1120mm (44.1”) 1570mm (61.8”) 1570mm (61.8”) 1570mm (61.8”) 1120mm (44.1”)
D
H
1035mm (40.7”) 1070mm (42.1”) 1240mm (48.8”) 1245mm (48.8”) 1445mm (56.9”) 2045mm (80.5”) 1070mm (42.1”)
1530mm (60.2”) 1730mm (68.1”) 1730mm (68.1”) 2060mm (81.1”) 2060mm (81.1”) 2050mm (80.7”) 1730mm (68.1”)
A 450mm (17.7”) 450mm (17.7”) 520mm (20.5”) 490mm (19.3”) 560mm (22”) 560mm (22”) 450mm (17.7”)
B 1230mm (48.4”) 1230mm (48.4”) 1230mm (48.4”) 1260mm (49.6”) 1260mm (49.6”) 800mm (31.5”) 1230mm (48.4”)
Air Flow & Operating Range TC-G Models
• -35℃ to 150℃ / -31℉ to 150℉
TC-GU Models
• -60℃ to 150℃ / -76℉ to 302℉
149
T
Temperature Chambers
Temperature Chambers (Floor Standing Models)
Operating & Constructional Features Constructional Features
Door Catch & Trim
• Standard environmental test chambers.
• High quality #304 stainless steel exterior and interior.
• Casters for easy mobility when installing or moving temp. test chamber.
•C onvenient maintenance-available to view total operating time.
• Spacious chamber volume maximum capacity of 1500L.
• Choose from 7 different model chambers based on size and temperature preference. - The series comes in 2 different models based on temp. ranges ranging in -35℃ to 150℃, -60℃ to 150℃ and six different volume capacities of 180L, 300L, 408L, 800L, 1000L and 1500L.
• Unique door lock & trim. - Vice lock type door and foam silicone packing to ensure a perfect seal. - Door open warning alarm.
• Inner door. - Optional inner glass door comes with four holes to handle samples inside the chamber. (excludes chambers with volume capacities of 800L or 1500L)
• Ventilation. - Ventilation vent is located at the upper right side of the unit.
• Chart recorder. (optional) - 6-point dot type recorder with a digital display.
• Viewing window for observation. - Tempered glass window provides a clear view of samples in the chamber, beneficial during testing. - Fluorescent lighting source included.
• Cable port for external probes or wires. - 50mm diameter cable port comes standard on the left side of the unit. Additional 50mm or 80mm diameter cable ports can be custom ordered. (optional)
• Easy cleaning of condenser air-filter. - To prevent deterioration of refrigeration system and keep filter dust free by periodically cleaning the filter.
Color LCD Controller
℃
25.0 ℃
100.0
Digital Recorder (optional)
150
Safety Features
• Leakage breaker for power supply.
• Over current protection.
• Overheat / overcool protection.
• Switch-off after alarm for over heating.
• Door open alarm.
• Vice lock door type locking mechanism.
Temperature Chambers
Temperature Chambers (Floor Standing Models)
Operating Features
• Microprocess PID control / Auto-tuning / Calibration.
•C hamber supports three different languages: English, Chinese, and Korean.
• Optimize CPU logic control system. - Optimum control of temperature with economical power consumption.
• Touch screen type display. - 5.7-inch Color LCD display with interactive input system. : Easily visible set value: set point (SP) /present value (PV) are also added on the colorful LCD controller. - Temperature, timer settings, operation condition. - Temperature and other operating parameters can be recorded using a chart recorder. • Programming operation.
Description
TC-G / GU
Programmable Pattern Capacity Pattern Repeat Time Max. Segments per a Pattern Available Max. Segments* Programmable Process Time per a Segment
120 999 100 1200 0 to 99 hr 59 min
Viewing Window
Cable Port
* Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment an patterns properly.
• Computer interface. - Save data in excel format. - Software provided. - Storage of program information, backup of value settings / recovery, and temperature values. - RS-232C port as standard offer.
•R S-485 communication port offers connection of a maximum of 9 temperature chamber units to one PC. (optional)
Multi-control Display
Single-control Display
Program Setting Display
Graph Display
Air Filter
Ventilation
151
T
Temperature Chambers
Temperature Chambers (Floor Standing Models)
Specifications & Ordering Information Model Chamber Volume (L / cu ft)
TC-G-180
TC-G-300
180 / 6.4
300 / 10.6
TC-G-408
0.2 / 0.36
at 100℃ (±℃ / ℉) at 100℃ (±℃ / ℉)
0.9 / 1.62
1 / 1.80
0.8 / 1.44
Mechanical single stage refrigerator system R-404A
Capacity (W)
1500
(68℉ to -31℉)
(air-cooled condenser)
R-404A (1st step), R-23 (2nd step) 4250
6000
Plate fin cooler Ni-Cr Wire Heater
Material
SUS TUBE Heater
2000
Drying Bulb (W)
3000
5000
Pt 100
Temperature Interior
Stainless steel #304
Exterior
Stainless steel #304
Insulation
Polyurethane foam 100mm (3.94”)
Door
Glass wool Tangent blower (90W)
4 sets of sirocco fan (4×90W)
Interior (mm / inch)
500×630×600 / 19.7×24.8×23.6
600×630×800 / 23.6×24.8×31.5
600×850×800 / 23.6×33.5×31.5
1000×800×1000 / 39.4×31.5×39.4
1000×1000×1000 / 39.4×39.4×39.4
1000×1000×1500 / 39.4×39.4×59.1
Exterior (mm / inch)
1025×1035×1530 / 40.4×40.7×60.2
1120×1070×1730 / 44.1×42.1×68.1
1120×1240×1730 / 44.1×44.8×68.1
1570×1245×2060 / 61.8×49×81.1
1570×1445×2060 / 61.8×56.9×81.1
1570×2045×2560 / 61.8×80.5×81.1
Viewing Windows Net Weight (kg / lbs)
200×330 / 7.9×13 310±10 / 683.4±22
375±10 / 826.7±22
270×330 / 10.6×13 400±10 / 881.8±22
Cable Port
Basically one hole provided / Ø50mm (2”) Optionally max. two holes available / Ø50 or 80mm (2 or 3.2”)
Interface Port
Basically RS-232C [RS-485(Maximum 9 Units Control)-optional] 1ph / 16.2A
Electrical Requirements (230V, 60Hz) Cat. No.
AAH81411K
Cat. No.
AAH81412K
AAH81422K
AAH81419K
AAH81429K
AAH81418K
AAH81428K
670±10 / 1477±22
AAH81441K
AAH81451K
3ph / 22.5A AAH81432K
AAH81442K
AAH81452K
3ph / 11.5A AAH81439K
3ph / 5.2A
Electrical Requirements (380V, 50Hz)
610±10 / 1345±22
3ph / 22.5A AAH81431K
3ph / 5.4A
Electrical Requirements (380V, 60Hz) Cat. No.
AAH81421K 1ph / 16.2A
Electrical Requirements (230V, 50Hz)
AAH81449K
AAH81459K
3ph / 11.5A AAH81438K
1) Technical data according to DIN 12880, IEC 60068.
※ Certification only for the TC-G-180∙300∙408. ※ Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%). ※ All specifications are under ambient temperature 20℃ (68℉), No Load.
152
85 From 20℃ to -35℃
Mechanical dual stage refrigerator system
(air-cooled condenser)
(mm / inch)
Cat. No.
0.5 / 0.9
On singe point control
Refrigerant
Air Flow
(W×D×H)
0.5 / 0.9
60 From -35℃ to 120℃ (-31℉ to 248℉)
Cooler
Dimension
0.4 / 0.72
60 From 20℃ to -35℃ (68℉ to -31℉)
Cooling (Min.) System
0.1 / 0.18
50 From -35℃ to 120℃ (-31℉ to 248℉)
Heating (Min.) Time
Material
TC-G-1500 1500 / 53
-35 to 150 / -31 to 302
Fluctuation 1) Variation 1)
Sensor
1000 / 35.3
Cooling fuzzy control system
Range (℃ / ℉)
Heater
TC-G-1000
800 / 28.3
Programmable, Touch screen type controller (5.7” Color monitor)
Controller
Refrigeration
TC-G-800
408 / 14.4
Control System
Temperature
Certification only for the TC-G-180.300.408
AAH81448K
AAH81458K
750±10 / 1653.5±22
3ph / 28.5A AAH81462K 3ph / 15.2A AAH81468K
Temperature Chambers
Temperature Chambers (Floor Standing Models)
Specifications & Ordering Information Model
TC-GU-300 300 / 10.6
Chamber Volume (L / cu ft)
Cooling fuzzy control system
Control System
Programmable, Touch screen type controller (5.7” Color monitor)
Controller Range (℃ / ℉) Temperature
-60 to 150 / -76 to 302 without humidity *best programmable control range : -50 to 140 / -58 to 284 0.3 / 0.54
Fluctuation 1) at 40℃ (±℃ / ℉)
0.5 / 0.9
Variation 1) at 40℃ (±℃ / ℉) Time
Heating (Min.) Cooling (Min.) System
Refrigeration
Refrigerant
60 From -60℃ to 120℃ (-76℉ to 248℉) 65 From 20℃ to -60℃ (68℉ to -76℉) on singe point control Mechanical single stage refrigerator system (air-cooled condenser) R-404A (1st step), R-23 (2nd step) 3000
Capacity (W)
Plate fin cooler
Cooler Heater
Material
Ni-Cr Wire Heater 2000
Drying Bulb (W)
Pt 100
Temperature Sensor Interior Material
Exterior Insulation
Stainless steel #304 Stainless steel #304 Polyurethane foam 100mm (3.94”) Glass wool
Door
Tangent blower (90W)
Air Flow Dimension (W×D×H)
Interior (mm / inch)
600×630×800 / 23.6×24.8×31.5
Exterior (mm / inch)
1120×1070×1730 / 44.1×42.1×68.1
Viewing Windows (mm / inch) Net Weight (kg / lbs)
Cable Port Interface Port
200×330 / 7.9×13 375±10 / 870.8±22 Basically one hole provided / Ø 50mm (2”) Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”) Basically RS-232C [RS-485(Maximum 9 Units Control)-optional]
Electrical Requirements (230V, 60Hz)
1ph / 24.3A
Cat. No.
AAH81521K
Electrical Requirements (230V, 50Hz)
1ph / 24.3A
Cat. No.
AAH81522K
Electrical Requirements (380V, 60 / 50Hz) Cat. No.
3ph / 8.3A AAH81528K
1) Technical data according to DIN 12880, IEC 60068.
※ Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%). ※ All specifications are under ambient Temperature 20℃ (68℉), No Load.
153
T Please visit
Temperature Chambers
Temperature Chambers (Tabletop Models) .com
For further information on Jeio Tech´s Temperature Chamber products Information is readily available on our website.
TC-KE-100
TC-ME-100 with stand (optional)
※ In the year of 2012, this products design can be changed without prior notice.
154
Temperature Chambers
Temperature Chambers (Tabletop Models)
Dimension (TC-KE / ME Models)
Models TC-KE
TC-ME
Capacity 25L (0.9cu ft) 65L (2.3cu ft) 100L (3.53cu ft) 25L (0.9 cu ft) 65L (2.3 cu ft) 100L (3.53 cu ft)
W 520mm (20.5”) 570mm (22.4”) 650mm (25.6”) 610mm (24”) 660mm (26”) 760mm (29.9”)
D 760mm (29.9”) 890mm (35”) 1000mm (39.4”) 855mm (33.7”) 970mm (38.2”) 1070mm (42.1”)
H 867mm (34.1”) 1010mm (39.8”) 1050mm (41.3”) 920mm (36.2”) 1065mm (41.9”) 1085mm (42.7”)
A 200mm (7.9”) 235mm (9.3”) 263mm (10.4”) 220mm (8.7”) 258mm (10.2”) 318mm (12.5”)
B 467mm (18.4”) 540mm (21.2”) 557mm (21.9”) 498mm (19.6”) 570mm (22.4”) 56.3mm (22.2”)
Air Flow & Operating Range TC-KE Models
• -35℃ to 150℃ / -31℉ to 302℉
TC-ME Models
• -20℃ to 120℃ / -4℉ to 248℉
155
T
Temperature Chambers
Temperature Chambers (Tabletop Models)
Operating & Constructional Features Constructional Features
• Small size and light weight.
• Compact design with high performance.
• Choose from 6 different model chambers based on size and temperature preference. - The series comes in 2 different model based on temp. ranging in -35℃ to 150℃, -20℃ to 120℃ and three different volume capacities of 20L, 65L, 100L.
• Efficient system with durable materials. - The evaporating system for better thermal efficiency with corrosion-resistant materials. - The heating system with minimized potential heat when heating or cooling for prompt reaction time and advanced performance.
• Viewing window. - A tempered glass window provides a clear view of samples in the chamber, beneficial during testing.
• Cable port for external probes or wires. - 50mm diameter cable port comes standard on the left side of the unit. Additional 50mm or 80mm diameter cable ports can be custom ordered. (optional)
• Optional stand for space-saving layout. - For use in limited spaces: stand and casters.
※ Be sure to secure the stand onto floor with earthquake resistant fitting for your safety when using stand.
Inner Glass Door
Safety Features
Controller
Portable Recorder (optional)
156
• Leakage breaker for power supply.
• Over current protection.
• Overheat protection.
• Switch-off after alarm for over heating.
• Door open alarm.
Temperature Chambers
Temperature Chambers (Tabletop Models)
Operating Features
• Microprocessor PID control / Auto-tuning / Calibration.
• Digital LCD display with touch-sensitive keys.
• Easy operation with wide LCD screen. -T emperature / timer settings and operating condition.
• Program patterns are memorized for 10 years due to a battery built into the PCB.
• Expansion parameter inputs. (displayed by letters)
• Programming operation. Description Programmable Pattern Capacity
TC - KE / ME 10
Pattern Repeat Time
999
Max. Segments per a Pattern
100
Available Max. Segments* Programmable Process Time per a Segment
100
Door Handle (TC-KE Models only)
0 to 99 hr 59 min
* Even though the max. segments per a pattern are 100, available total segments are up to 300 not 3000, so you need to arrange the number of segment and patterns properly.
• Computer interface. (optional) - Software provided. - Save data in excel format. - Storage of program information, backup of value settings / recovery, and temperature values. - RS-232C port as standard offer.
• Chart Recorder. (optional) - 6 point dot type recorder with digital display.
• RS-485 communication port offers a maximum of 9 temp. chambers to be connected by one PC. (optional)
Multi-control Display
Single-control Display
Program Setting Display
Graph Display
Water Tank
Cable Port
157
T
Temperature Chambers
Temperature Chambers (Tabletop Models)
Specifications & Ordering Information Model
TC-KE-025 25 / 0.9
Chamber Volume (L / cu ft)
TC-KE-065 65 / 2.3 PID control (LCD Type)
Controller
-35~150 / -31~302
Range (℃ / ℉) Temperature1)
TC-KE-100 100 / 3.53
± 0.5°C
Fluctuation2) at 50℃ (±℃ / ℉) Variation2) at 50℃
± 1°C
(±℃ / ℉)
Heating
60 (-40℃ 100℃)
Cooling3)
70 (25℃ -35℃)
System
Mechanical single stage refrigerator system (air-cooled condenser)
Refrigerant
R-404A
Capacity (W)
470
3)
Time
Refrigeration
Heater
Material
Ni-Cr Wire Heater
Drying Bulb (W)
1000
Temperature Sensor
Material
565
657
1200
1500
Plate fin cooler (cooper)
Cooler
Pt 100
Internal
Stainless steel #304 (2B polish)
External
Stainless steel #304 & Steel, 0.8t, Double painted & baked
Insulation
Polyurethane foam 100mm [3.94”]
Door
Glasswool
Air Flow (sirocco fan)
60W×1EA
Interface Port
Basically RS-232C, [RS-485:optional]
Cable Port
Basically one hole provided / Ø50mm (2”) Optionally max. two holes available / Ø50 or 80mm (2 or 3.2”)
Dimension (W×D×H)
Electrical Requirements
60W×1EA
Internal (mm / inch)
350×220×350 / 13.8×8.7×13.8
400×330×495 / 15.7×13×19.5
500×380×530 / 19.7×15×20.9
External (mm / inch)
610×855×920 / 24×33.7×36.2
660×970×1065 / 26×38.2×41.9
760×1070×1085 / 29.9×42.1×42.7
Weight (kg / lbs)
110 ±10 / 242.5 ±22
140 ±10 / 308.6 ±22
150 ±10 / 330.7 ±22
7.4A
8.8A
10.8A
AAH86111K
AAH86121K
AAH86131K
7.1A
8.4A
10.3A
AAH86112K
AAH86122K
AAH86132K
AC230V, 1ph, 60Hz AC230V, 1ph, 50Hz
1) All specifications are under ambient temperature 20℃ (68℉), no load. 2)Technical data according to DIN 12880, IEC 60068. 3) Up to 98% of the set value.
* 80mm cable access hole is NOT available for 25L chamber (TC-ME-025). * Above the dimensions are NOT included size of attached accessories. ※Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%). Recommended ambient temperature : +20℃ (68℉).
158
60W×2EA
Temperature Chambers
Temperature Chambers (Tabletop Models)
Specifications & Ordering Information Model
TC-ME-025 25 / 0.9
Chamber Volume (L / cu ft)
Program controller (LCD type)
Controller Range (℃ / ℉)
-20 to 120 / -4 to 248
Program Control (℃ / ℉)
-15 to 120 / -5 to 248
Fluctuation 1) (±℃ / ℉) at 100℃
0.4 / 0.72
0.3 / 0.55
0.3 / 0.55
Variation (±℃ / ℉) at 100℃
2 / 3.60
1.9 / 3.42
1.8 / 3.24
1)
Time
Heating (Min.)
55 From -15℃ to 120℃ (5℉ to 248℉)
Cooling (Min.)
60 From 20℃ to -15℃ (68℉ to 5℉) on singe point control * Mechanical single stage refrigerator system (air-cooled condenser)
System Refrigeration
R-404A
Refrigerant 250
Capacity (W)
250 Ni-Cr Wire Heater
Material 800
Drying Bulb (W)
1000
Interior
Stainless steel #304
Exterior
Stainless steel, 1mm (0.04”) / Double painted & baked Polyurethane foam 50mm (1.97”)
Insulation
Glass wool
Door
Sirocco fan (60W)
Air Flow
Dimension (W×D×H)
Interior (mm / inch)
350×220×350 / 13.8×8.7×13.8
400×330×495 / 15.7×13×19.5
500×380×530 / 19.7×15×20.9
Exterior (mm / inch)
500×760×850 / 19.7×29.9×33.5
550×890×1000 / 21.7×35×39.4
650×1000×1030 / 25.6×39.4×40.6
Net Weight (kg / lbs)
80±5 / 176±11
110±5 / 242±11
130±5 / 286±11
Basically one hole provided / Ø 50mm (2”) Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”)
Cable Port
Basically RS-232C [RS-485 (Maximum 9 Units Control) - optional]
Interface Port Electrical Requirements
1000
Pt 100
Temperature Sensor
Material
375
Plate fin cooler (cooper)
Cooler Heater
TC-ME-100 100 / 3.53
Cooling PID control system
Control System
Temperature
TC-ME-065 65 / 2.3
AC230V, 1ph, 60Hz AC230V, 1ph, 50Hz
5.3A
6.1A
6.8A
AAH86011K
AAH86021K
AAH86031K
5.1A
6A
6.5A
AAH86012K
AAH86022K
AAH86032K
1)Technical data according to DIN 12880, IEC 60068.
* 80mm cable access hole is NOT available for 25L chamber (TC-ME-025). * Above the dimensions are NOT included size of attached accessories. ※ Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%). ※ All specifications are under ambient temperature 20℃ (68℉), no load.
159
T
Temperature Chambers Accessories & Options
Viewing Window
Inner Door
Recorder
Viewing Window
Warning Signal Light
Cable Port
• An observation window is only installed in the floor type chambers.
• A tempered dual window provides a clear view of samples during testing.
• A through hole of 50 or 80mm dia. (2.0 or 3.2˝ dia.) is provided on the wall of chamber to allow electrical cables to be introduced into the chamber. A 50mm hole is provided, maximum two holes (50 or 80mm) are optional.
Inner Door
Shelf
•A n inner glass door for quick viewing of samples and to prevent outside air from flowing in. (Table top - without hand entry ports.)
Temperature Recorder
• 6-point dot type recorder.
• digital display.
•W ire and perforated type shelves (shelf brackets included) are made of durable stainless steel. Standard shelves and shelf brackets come standard.
Warning Signal Light
• A malfunction indicator can be placed on the right upper side.
Tabletop Chambers Cat. No. AAA8T504 AAA8T506 AAA8T540 AAA8T541 AAA8T542 AAA80550 RTD679 RTD680 RTD681 AAA80602-6 AAA80602-7 AAA80602-8 AAA8T612 AAA8T613 AAA8T610 AAA8T611 AAA80631 AAA80632 AAA80633 AAA80634 AAA80635 CFA1910
Description
25L
Portable Recorder (6 points) Portable Recorder (digital, 6 channels) RS-232C Interface Converter included a Cable (5m / 16.4ft) RS-485 Interface Converter included a Cable (5m / 16.4ft) Interface Cable (5m / 16.4ft) Warning Signal Lamp Wire Shelf for TC - KE / ME - 025 Wire Shelf for TC - KE / ME - 065 Wire Shelf for TC - KE / ME - 100 Perforated Shelf for TC - KE / ME - 025 Perforated Shelf for TC - KE / ME - 065 Perforated Shelf for TC - KE / ME - 100 Cable Port (Ø 50mm / 2.0”) for TC - ME Models Cable Port (Ø 80mm / 3.2”) for TC - ME Models Cable Port (Ø 50mm / 2.0”) for TC - KE Models Cable Port (Ø 80mm / 3.2”) for TC - KE Models Stand for TC - KE / ME - 025 Stand for TC - KE / ME - 065 Stand for TC - KE / ME - 100 Two Step Stand for TC - KE / ME - 025 Two Step Stand for TC - KE / ME - 065 Temperature Sensor (RTD type)
• • • • • • • • • • • • •
TC-KE 65L • • • • • • • • • • • • •
100L • • • • • • • • • • • •
25L • • • • • • • • • • • • •
TC-ME 65L • • • • • • • • • • • • •
※ 80mm cable access hole is NOT available for 25L chamber.
Wire & Perforated Shelves for Tabletop Chambers Models TC - KE / ME - 025 TC - KE / ME - 065 TC - KE / ME - 100
* Only for wire shelf.
160
Included* 2 2 2
Maximum 7 10 10
Description Space
20mm (0.8”) 20mm (0.8”) 20mm (0.8”)
Dimension (W×L)
195×310mm (7.7×12.2”) 280×360mm (11×14.2”) 330×460mm (13×18.1”)
100L • • • • • • • • • • • •
Temperature Chambers Accessories & Options
Floor Standing Chambers Cat. No.
Description Recorder (6 points) Recorder (digital, 6 channels) RS-485 Interface Converter included a Cable (5m / 16.4ft) Interface Cable (5m / 16.4ft) Warning Signal lamp Inner Glass Door (only for 180L chambers) Inner Glass Door (only for 270, 300, 408L chambers) Wire Shelf for TC - G - 180 Wire Shelf for TC - G/GU - 300 Wire Shelf for TC - G - 408 Wire Shelf for TC - G - 800 Wire Shelf for TC - G - 1000, 1500 Perforated Shelf for TC - G - 180 Perforated Shelf for TC - G/GU - 300 Perforated Shelf for TC - G - 408 Perforated Shelf for TC - G - 800 Perforated Shelf for TC - G - 1000 , 1500 Cable Port (Ø 50mm / 2.0”) Cable Port (Ø 80mm / 3.2”) Temperature Sensor (RTD type)
AAA8T500 AAA8T505 AAA8T541 AAA8T542 AAA80550 AAA81552 AAA81551 EDA8212 EDA8213 EDA8214 EDA8215 EDA8216 AAA80602-1 AAA80602-2 AAA80602-3 AAA80602-4 AAA80602-5 AAA8T610 AAA8T611 CFA1185
180L
300L
• • • • • • • • • • • •
• • • • • • • • • • • •
TC-G 408L • • • • • • • • • • • •
800L • • • • • • • • • • • •
1000L 1500L • • • • • • • • • • • •
• • • • • • • • • • • •
Wire & Perforated Shelves for Floor Standing Chambers Models TC - G - 180 TC - G/GU - 300 TC - G - 408 TC - G - 800 TC - G - 1000, 1500
Included* 2 2 2 2 2
Maximum 9 10 10 14 14
Description Space 40mm (1.6”) 40mm (1.6”) 40mm (1.6”) 40mm (1.6”) 40mm (1.6”)
Dimensions (W×L) 463×518mm (17.2×20.4”) 518×558mm (20.4×22.0”) 560×740mm (22.0×29.1”) 750×960mm (30.0×37.8”) 950×960mm (37.4×37.8”)
* Only for wire shelf. ※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details.
161