Ladda Ner Produktkatalog

   EMBED


Share

Transcript

Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE Series 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co., Ltd. ISO 9001 Certified number : 01 100 79269 ISO 14001 Certified number : 310102-UK Fujitsu General (Shanghai) Co., Ltd. ISO 9001 Certified number : 00608Q11061R2M ISO 14001 Certified number : 00609E20454R2M Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd. “ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas. *Echelon ®, LONWORKS ®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. *BACnet ® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE). The colors may be different from the actual colors because this catalog is printed matter. Product specifications are subject to change without notice. Distributed by : Copyright© 2011 Fujitsu General Limited. All rights reserved. 6NNJ24-1212E The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only energy savings and comfort but also ease of design, installation, and maintenance. Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. OU UTDOOR UNITS Small Office Various Line-up for each buildings 4HP 5HP 6HP AJ*A40LALH AJ*A45LALH Large Homes AJ*A54LALH AJ* : AJY (FUJITSU), AJH (GENERAL) Building owners Installers End users Service and Management companies Wide lineup of indoor units and controllers to support a variety of properties. INDOOR UNITS CONTROLLERS Central Controller 02 Compact Cassette Cassette Low Static Pressure Duct Slim Duct (Drain Pump internal) Medium Static Pressure Duct High Static Pressure Duct Floor / Ceiling Ceiling Wall Mounted (EEV internal / EEV external) Wall Mounted Central Remote Controller Individual Controller Group Remote Controller Touch Panel Controller System Controller (Software) Wireless Remote Controller Simple Remote Controller Wired Remote Controller Wired Remote Controller (Touch Panel) 03 FEATURES High Energy Saving Efficiency in actual operation The building load is the range of almost 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate performance air conditioner corresponding not only to the rated performance at 100% load, but also to low to medium load Load curve (a typical office building) Building load (%) 100 80 Large propeller fan DC inverter control 60 High performance and low noise realized by large propeller and optimization of angle. Efficiency is improved by mounting of new active filter module. 40 20 0 0 3 6 9 12 15 18 21 24 Time (h) DC fan motor Miniaturized, low noise, high efficiency, multi-stage DC fan motor is mounted. Subcool heat exchanger Pressure Cooling performance is improved by mounting of dual tube heat exchanger. High EER / COP 4.29 3.72 3.60 Large heat exchanger High part load performance (6HP class) 4.20 Heat exchange performance is substantially improved by mounting of 3-row large heat exchanger. 3.95 3.45 66 % UP 50% 5.73 46 % UP : COP 6 HP 100% 3.45 EER Cooling part load 04 Enthalpy 100% 3.95 Optimized refrigerant flow design Highly accurate parts DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. High Compressor efficiency : EER 5 HP Cooling performance improved 50% 5.75 High efficiency compressor motor 4 HP effect COP Heating part load Conditions : Connected indoor units: AUXA30GALH+AUXD24GALH Cooling : indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWB Heating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB DC Twin Rotary compressor Compressor capacity High 05 FEATURES More Comfort Operation Performance is Efficiently Controlled. Powerful Heating Room temperature set point limitation Economy operation The minimum and maximum temperature range can be set. The temperature setting is offset automatically over a certain period of time. Heating capacity is improved at low outdoor temperature by our advanced technology. Heating (°C) Cooling 30 Heating capacity (kW) Various Energy Saving Function 16.6 Set Temp. Down Heating Set Temperature MAX. - 4°C 28 Down Down 33% Down Economy operation Control Temperature 26 J-II series (6HP) Current model (6HP class) UP ! Economy operation 24 Set Temp. 22 Economy operation Economy operation Control Temperature 20 18 MAX. +2°C Cooling Set Temperature 16 Up -20 Up -10 0 7 Outdoor temperature (°C) 14 12 10 Original Set Temp. Set point limitation setting Capacity save operation Low Noise Design The power consumption at peak can be limited. Setting range 100% Low noise design of outdoor unit Capacity Capacity save Low noise mode Significantly reduced noise by optimized airflow structure design of outdoor unit. Setting level Outdoor unit can be switched to silent mode, depending on the installation environment. Current model 56dB J-II series (4~ 6HP) 53dB 80% 60% Noise level Rated noise value -5dB ~ -6dB 40% 0% Low noise mode Central Remote Controller Time 6HP class (Cooling) Time Various Comfort Control Function Wasteful Operation is Prevented. Auto Off function Able to prevent wastage of energy. OFF OFF OFF Easy auto changeover function Non-stop oil recovery operation Auto louver grill (Option for Slim Duct) At the auto mode, cooling and heating mode is switched automatically to maintain the setting temperature. The product continues to operate without stopping the cooling or heating operation during oil recovery modes. Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet Temp. (°C) Cooling operation Heating operation With Auto Louver 18:00 20:00 22:00 Set Temp. J-II series 35 ON 30 Operation stopped at oil recovery Heating operation Function setting is required. 1 indoor unit (Master) can apply this function. 06 Current model Time ON 25 20 OFF Temperature(°C) 40 15 Time 07 FEATURES More Convenience Central Control of Small Office, Shop, etc. Building Management System Individual and Central Control of Large Homes A/C central controller Convertor for BMS Control Central Remote Controller Wireless Remote Controller Wired Remote Controller UTY-LNH* UTY-RNK* UTY-DCG* Network Convertor for LONWORKS ® UTY-VLGX Network Convertor UTY-VGGXZ1 BACnet ® Gateway (Software) Group Remote Controller UTY-CGG* UTY-ABGX Max. controllable 18 indoor units Lighting facilities Ventilation system Central Remote Controller Security system UTY-DCG* Max. controllable 100 indoor units • Automatic display of number of connected indoor unit • Max. controllable 100 units or Touch Panel Controller Group Remote Controller UTY-CGG* UTY-DTG* Wired Remote Controller (Touch Panel) Max. controllable 400 indoor units Simple Remote Controller System Controller (Software) UTY-APGX Max. controllable 1,600 indoor units • Max. controllable 18 indoor units UTY-RSK* UTY-RHK* With operation mode Without operation mode UTY-RNR* R*: RY (FUJITSU), RG (GENERAL) K*: KY (FUJITSU), KG (GENERAL) H*: HY (FUJITSU), HG (GENERAL) G*: GY (FUJITSU), GG (GENERAL) G*: GY (FUJITSU), GG (GENERAL) Control system composition example Control system composition example VRF network system Building control computer Central Remote Controller or Network Convertor for LONWORKS ® Central Remote Controller or System Controller (Software) BACnet ® Gateway (Software) 08 Touch Panel Controller Network Convertor Wired Remote Controller Group Remote Controller Group Remote Controller Wired Remote Controller + Simple Remote Controller Simple Remote Controller IR Receiver Unit + Wireless Remote Controller Wireless Remote Controller Wired Remote Controller + Wireless Remote Controller 09 FEATURES More Design Flexibility Easy Installation Long Piping Length Easier Installation Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design. Easy piping connection Flexible installation of outdoor unit Improvement of the reliability by decreasing the flare connection. Corresponds to the outdoor unit concentration installation. J-II series Actual piping length Height difference between outdoor 120 m max. and indoor units Flare connection Previous model EV kit 30 m max. Terminal box Power supply cable Piping length from first separation tube to the farthest indoor unit 15 m max. Total piping length • Decreasing wiring mistakes by using non-polar 2 wires.(Remote controller cable is 3 wires) 180 m max. • Improvement of wiring installation by common with V-II power supply method. 2 to 7 units Indoor unit 2 to 8 units 6 HP 2 to 9 units Flexible installation by 4 way pipe direction Convenient Commissioning Support Number of connectable indoor unit 5HP Power supply (Indoor ) Easy wiring connection High Capacity Connection 4 HP Reduced installation intervals by front access Power supply (Outdoor ) Height difference between indoor and indoor units 40 m max. Flare connection 12 types, 48 models Connectable indoor unit capacity range Automatic address setting function Connection check function The address of each indoor unit can be automatically set by button switch of outdoor unit. Possible to confirm whether wiring connection and address setting are correct by check run function for a short time. 130 % max. 3 7 1 0 2 4 5 6 • Display connected indoor unit numbers • Duplicately set address number of indoor unit can be displayed Press the push button of outdoor unit. Wide operating range Installation in extreme temperature conditions is possible due to an increase in operational range. Cooling : -5°C~46°C Heating : -20°C~21°C (°C) 50 40 Heating 21°C 30 20 10 -10 Easy to connect with V-II communication system -20°C area Operation possible in heating. 0 -20 10 Cooling 46°C -5°C -20°C J-II system V-II system Connects without a converter It is possible to connect directly with the transmission cable of the V-II system without convertor. 11 FEATURES OUTDOOR UNITS Specifications Easy Maintenance AJ*A40LALH Model name Capacity range HP Max.connectable indoor unit*1 AJ*A45LALH 4 5 6 7 8 9 Power source 1Ø, ~ 230 V, 50 Hz Easy to read 7-segment LED Confirm detail operational and trouble status without using specific equipment Input power Error status can be checked easily via the indoor unit wired controller An error code is displayed on a liquid crystal screen. 12.1 14.0 Heating 13.6 16.0 18.0 Cooling 3.25 3.89 4.49 4.56 Cooling Capacity Design for Easy Maintenance kW kW Faulty unit number (Remote controller address) 3.17 3.81 EER Cooling 3.72 3.60 3.45 COP Heating 4.29 4.20 3.95 6,200 6,400 6,900 50 51 53 52 53 55 W/W m 3/h Air flow rate Cooling Sound pressure level dB(A) Heating Heat exchanger fin Blue fin mm Weight kg Refrigerant charge kg Error code Liquid Connection pipe diameter 1,334 x 970 x 370 117 4.8 5.3 9.52 mm Gas 7-segment LED 15.5 Heating Dimensions (H×W×D) Wired Remote Controller AJ*A54LALH 15.88 Cooling Operation temperature range 19.05 -5 to 46 °CDB Heating SU MO TU WE TH FR SA -20 to 21 Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function might work when using it outside the operation range. Simple Remote Controller Dimensions Remote controller address Error code 166 Movable PCB panel 650 154 AJ*A40LALH / AJ*A45LALH / AJ*A54LALH 32 Emergency Stop Function (410) 40 51(Gas) 370 43(Liquid) (Unit : mm) Easier for maintenance work behind the PCB 36 970 370 12 Terminal blocks (Transmission) Central Remote Controller or Emergency stop function Terminal blocks (Power) Emergency stop function Emergency stop function 3-Way valve (Liquid) 907 Touch T hP Panell Controller 1000 Note : In case of received Emergency alarm by Indoor / outdoor unit : All units connected within same refrigerant system will be stopped. Central Remote Controller or Touch Panel Controller : all units connected within VRF network system with Central Remote Controller or Touch Panel Controller will be stopped. 32 1334 Emergency alarm can be received by indoor, outdoor units, Central Remote Controller or Touch Panel Controller when they received it, all units will be stopped. AJ* : AJY (FUJITSU), AJH (GENERAL) 21 Detail 21 65 Ø28 (Cable port) Ø28 (Cable port) Pipe port A 14 15 50 Ø28 (Cable port) Ø28 (Cable port) Pipe port 55 A 65 142 155 120 50 131 87 25 95 Pipe port 50 Equipment Detail (Diagram) USB adaptor (Field supplied) 89 Software 227 Service Tool UTY-ASGX • Last 5 min. operation memory can be also recorded. 341 305 • Detail operation status and recent error history can be checked and analyzed by using Service Tool. Ø28 (Cab le port) Connection to Service Tool 50 Transmission cable (Non-polar 2 wires) 21 Trouble diagnosis by Service Tool 279 ((Liquid valve)) 297 (Gas valve) le port) ab Ø28 (C 70 111 3-Way valve (Gas) 50 438 Pipe & cable port 622 12 AJ* : AJY (FUJITSU), AJH (GENERAL) 13 INDOOR UNITS Indoor Unit Lineup Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs. 12 Types, 48 Models, Capacity range from 2.2kW to 14.0kW Capacity range (kW) Model code 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 12.5 14.0 7 9 12 14 18 24 30 36 45 54 AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH ARXA30GBLH ARXA36GBLH ARXA45GBLH ARXC36GATH ARXC45GATH AB*A36GATH AB*A45GATH Compact Cassette Cassette Cassette Low Static Pressure Duct ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH Slim Duct (Drain pump internal) Duct ARXD24GALH Medium Static Pressure Duct ARXA24GBLH High Static Pressure Duct Floor (*Same as Ceiling models) Floor AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH Concealed Floor (*Same as Low Static Pressure Duct models) ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH AB*A30GATH AS*A12GACH AS*A14GACH AS*A18GACH AS*A24GACH AS*A30GACH Slim Concealed Floor (*Same as Slim Duct models) Ceiling Ceiling AB*A54GATH Wall Mounted AS*A07GACH Wall Mounted AS*A09GACH With this model, Wall Mounted (EEV external) connection of AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH EV kit is necessary. AB* : ABY(FUJITSU), ABH(GENERAL) AS* : ASY(FUJITSU), ASH(GENERAL) 14 15 INDOOR UNITS Compact Cassette AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH Ceiling panel A B C D 2 Quiet quality High efficiency design by 2 stage structure Optimization of wing form (laminar wing type) and wing number (7 blades each) An evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams. Adoption of laminar wing Quiet 2 Long life filter : standard equipment 3 Adaptation of transparent drainage parts 570mm Optional parts 570mm Spin direction No airflow separation Airflow direction Specifications Dimensions AUXB07GALH AUXB09GALH AUXB12GALH AUXB18GALH AUXB24GALH 2.2 2.8 3.6 4.5 5.6 7.1 2.8 3.2 25 25 4.1 5.0 6.3 8.0 29 35 36 540 550 84 600 680 710 1,030 Power source (Unit : mm) Models: AUXB07 / AUXB09 / AUXB12 / AUXB14 / AUXB18 / AUXB24 530 590 580 830 390 390 400 450 High 34 35 37 38 41 50 30 30 34 34 35 44 25 25 27 27 27 30 dB(A) Low mm kg Liquid (Flare) mm Drain ø15.88 146 285 285 183 40 UTG-UF*C-W mm 50 x 700 x 700 kg 2.6 F* : FY (FUJITSU) ; FG(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. Ceiling Gas pipe Control Box Liquid pipe 262 Weight ø12.70 ø25 (I.D) ; ø32 (O.D.) Model name Dimensions (H x W x D) 17 ø9.52 30 Gas (Flare) 15 ø6.35 123 Connection pipe diameter Drain hose 19 Weight IR receiver 245 x 570 x 570 215 Dimensions (H x W x D) 114 Med 370 450 350 □ 570 : Indoor unit 450 350 114 Sound pressure level m3/h Low Med 530 High 530 Hanging bolt position 700 700 kW W Airflow rate 16 AUXB14GALH Air Outlet Shutter Plate : UTR-YDZB Insulation Kit for High Humidity : UTZ-KXGC Fresh Air Intake Kit : UTZ-VXAA 230V ~, 50Hz Input power Cassette Grille Worlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size) □ 580 to 660 Ceiling openings Quiet In the case of a previous fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven. Heating 3.0 3.0 3.0 3.0 B : 2-stage turbo fan D : Panel Compact design Previous turbo fan Cooling 2.7 2.7 2.7 2.7 2.7 2.7 Airflow runs through smoothly along the laminar wing Slow Capacity High ceiling mode 07 09 12 14 18 24 During installation, maintenance and operation, the drain pump and kit can be checked easily. Laminar wing 20%UP Model name Standard mode 540 Hanging bolt position = Model code 30 + Heat exchange efficiency The maximum height from floor to ceiling (m) Maintenance of fan motor and fan A : Fan motor C : Bell-mouth Designed by CFD-analysis (fluid) simulations Wind velocity Fast The compact cassette can be installed up to a height of 3.0m (12/14/18/24). Grille cover Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily. 2-stage turbo fan 2-stage turbo fan 3 High ceiling mode 1 1-stage Max. 700mm 1 Compact size panel design that fits standard ceiling panel (600x600mm) 2-stage High lift drain pump Improvement of the airflow distribution Models 17 INDOOR UNITS Cassette Improvement of the airflow distribution Models AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH High lift drain pump The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution. Front part Ceiling panel Ceiling Bottom view Rear part Powerful, wide airflow and quiet operation Max. 850mm High ceiling mode Much less temperature irregularity happens by spreading airflow widely Round louvre This cassette can be installed up to a height of 4.2m (36/45/54). The maximum height from floor to ceiling (m) Model code Adjustment of hanger position is possible after installation High efficiency turbo fan with 3-dimensional blade High ceiling mode 3.0 3.0 3.2 3.2 3.2 3.2 3.5 3.5 3.6 4.2 4.2 4.2 18 24 30 36 45 54 Detachable Grille corner High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger. Standard mode Previous turbo fan Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling. Adjustment can be done just taking off the corner part 500mm 450mm 3-dimensional blade Previous blade Optional parts One way aperture installation Heat exchanger < Motor side > Heat exchanger < Motor side > Separation phenomenon of airflow causes noise Quiet Wind velocity Fast No airflow separation Parallel apertures Uneven airflow Slow : Turbulent flow noise Dimensions AUXA36GALH AUXA45GALH AUXA54GALH 230V ~, 50Hz 5.6 7.1 9.0 11.2 12.5 14.0 6.3 8.0 10.0 12.5 14.0 16.0 39 46 59 80 99 119 1,150 1,280 1,600 1,800 1,900 2,000 940 1,040 1,300 1,300 1,370 1,370 Low 870 870 1,100 1,100 1,100 1,100 High 36 38 40 44 46 47 30 33 38 38 39 39 29 29 33 33 33 33 W High Med dB(A) Low Dimensions (H x W x D) Weight Connection pipe diameter mm 246 x 840 x 840 kg 22 27 mm Weight ø15.88 ø19.05 358 (Control) Box ø25 (I.D.) ; ø32 (O.D.) Drain Model name Dimensions (H x W x D) Drain hose ø9.52 Liquid (Flare) Gas (Flare) 288 x 840 x 840 358 278 mm 50 x 950 x 950 kg 5.5 G* : GY(FUJITSU) ; GG(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 60 40 UTG-UG*A-W 298(256) Sound pressure level m3/h 200 Med 796 Hanging bolt position 950 Ceiling 10 Airflow rate IR receiver (Option) 142 Input power kW 142 Heating Liquid pipe Gas pipe 44 140 Cooling Capacity Models: AUXD18 / AUXD24 (Slim type) AUXA30 / AUXA36 / AUXA45 / AUXA54 420 699 Hanging bolt position □ 860 to 910 Ceiling opening AUXA30GALH □ 840 : Indoor unit AUXD24GALH Power source 607 AUXD18GALH Model name (Unit : mm) ( ) : AUXD18 / AUXD24 950 : Airflow direction Specifications 18 UTY-LRH*B1 UTR-YDZC UTG-BGYA-W UTZ-KXGA / UTZ-KXGB UTG-AGYA-W UTZ-VXGA H*: HY(FUJITSU), HG(GENERAL) : Spin direction Cassette Grille IR Receiver Unit : Air Outlet Shutter Plate : Panel Spacer : Insulation Kit for High Humidity : Wide Panel : Fresh Air Intake Kit : Wire hole 19 INDOOR UNITS Low Static Pressure Duct / Concealed Floor Models ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH Compact design Flexible installation Ultra-slim duct air conditioner for easy installation Ceiling concealed Max. 850mm Height 217mm ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH Slim size (217mm) allows installation even where the space behind the ceiling is narrow. Floor concealed Small and compact indoor unit suitable for many applications Two-direction drain piping Concealed Floor Filter (Accessory) ARXB07 / ARXB09 Duct indoor unit Low noise level Filter (2pcs.) Two-direction drain piping Low static pressure mode 7 Model Static pressure range Pa Noise level (Low speed) dB(A) 9 12 14 Airflow drop prevention Air-intake Air intake direction can be selected to match the installation site. Low noise realized 18 Optional parts 0 to 50 24 27 25 30 Filter (3pcs.) Normal mode Airflow A low noise level has been achieved for each capacity ARXB12 / ARXB14 / ARXB18 30 Bottom side Remote Sensor Unit : UTY-XSZX IR Receiver Unit : UTB-YWC Drain Pump Unit : UTZ-PX1BBA Back side Static pressure (Pa) Specifications Dimensions ARXB07GALH ARXB09GALH ARXB12GALH Power source High Med dB(A) Low Dimensions (H x W x D) Weight Connection pipe diameter 96 886 (596) 370 440 590 800 890 (Bolt pitch) 310 370 500 750 810 280 340 450 700 730 0 to 50 0 to 50 0 to 50 0 to 50 0 to 50 25 25 25 25 25 29 31 30 33 36 26 29 28 32 34 24 27 25 30 30 kg 15 mm Note : Specifications are based on the following conditions. ø6.35 ø9.52 ø15.88 Brackets 2 47 850 (560) 85 150 Airflow outlet 953 (663) 94 (50) ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Brackets 3 23 ø12.70 217 194 Control box 1 24 217 x 953 x 595 22 170 90 217 x 663 x 595 Drain 20 63 mm Liquid (Flare) Gas (Flare) 55 364 Sound pressure level 6.3 46 65 75 Pa Standard static pressure 5.6 5.0 587 Static pressure range 4.5 4.0 390 m3 / h Low 3.6 3.2 (Bolt pitch) Med 2.8 2.8 595 High 2.2 166 W Input power 886 (596) *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. 20 kW Models: ARXB07 / ARXB09 / ARXB12 / ARXB14 / ARXB18 Control box 600 (400) 10 Cooling Heating Airflow rate ARXB18GALH 150 Capacity ARXB14GALH 230V ~, 50Hz 217 Model name (Unit : mm) ( ) : AR7 / AR9 1 Refrigerant piping flare connection (Gas) 2 Refrigerant piping flare connection (Liquid) 3 Drain piping connection 21 INDOOR UNITS Slim Duct / Slim Concealed Floor Auto Louver Grille Kit (Option) High lift drain pump Models (Drain pump internal model) ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Max. Max. 850mm ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH Slim Duct 850mm Auto Louver Grille ARXD18GALH Drain hose is standard accessory Selectable with a wide range of static pressure Slim design and wide range of static pressure for flexible installation. ARXD24GALH Slim Concealed Floor By using DC fan motor, it is possible to change of static pressure range 0 to 90Pa. The change of static pressure range is possible by remote controller. Wired Remote Controller Static pressure range Wireles Remote Controller Filter (Accessory) 0 to 90 Pa ARXD07 / 09 / 12 / 14 / 18 *24 model is 0 to 50Pa Filter (2pcs.) ARXD24 Filter (3pcs.) Flexible installation Ceiling concealed Slim design Air-intake This model is slim design, it can install at the place where a ceiling is narrow. Air intake direction can be selected to match the installation site. Optional parts Floor concealed Drain port Remote Sensor Unit : UTY-XSZX IR Receiver Unit : UTB-YWC Auto Louver Grille Kit : UTD-GXSA-W (for ARXD07/09/12/14GALH) UTD-GXSB-W (for ARXD18GALH) UTD-GXSC-W (for ARXD24GALH) Height 198mm Bottom side Back side Specifications Dimensions High Med m3/ h Low Static pressure range 2.8 3.6 4.5 5.6 2.8 3.2 4.0 5.0 6.3 8.0 44 50 54 92 83 122 550 600 600 800 940 1,330 490 550 510 710 840 1,240 440 480 450 610 750 1,100 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 50 25 25 25 25 25 25 28 29 30 34 34 35 25 26 27 32 32 32 7.1 dB(A) Low kg Weight Connection pipe diameter 22 Liquid (Flare) Gas (Flare) 28 198 x 700 x 620 17 18 ø6.35 mm Drain Note : Specifications are based on the following conditions. 22 24 24 mm Dimensions (H x W x D) 28 29 198 x 900 x 620 198 x 1,100 x 620 22 26 30 48 F (All surroundings) E D C (Bolt pitch) 43 78 Med 168 High 198 Sound pressure level G 82 Pa Standard static pressure 51 10 ø9.52 ø12.70 ø15.88 ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. 174 W Input power 2.2 B A 31 ARXD07-14 ARXD18 A 700 900 1100 B 650 850 1050 C 734 934 1134 D 650 850 1050 E P100x6=600 P100x8=800 P100x10=1000 F 18xØ5 22xØ5 26xØ5 G 574 774 974 47 kW 78 55 Heating Airflow rate *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. 230V ~, 50Hz Cooling Models: ARXD07 / ARXD09 / ARXD12 / ARXD14 / ARXD18 / ARXD24 89 Capacity ARXD24GALH ARXD18GALH 152 71 Power source ARXD14GALH 30 ARXD12GALH 377 ARXD09GALH (Bolt pitch) ARXD07GALH Model name (Unit : mm) 119 Drain pump 163 Drain pump built-in 69 144 264 367 620 ARXD24 23 INDOOR UNITS Medium Static Pressure Duct Selectable with a wide range of static pressure Models ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH It is possible to change of static pressure range 0 to 150Pa. Easy maintenance See below for the case of rear suction type Static pressure range New model 1 0 to 150 Pa 1.Control box 2.Fan casing 4 3.Fan Can be installed for various location Low energy consumption by DC fan motor. Selectable with a wide range of static pressure. It can be installed in such locations as high-rise condominiums by low static pressure design. 4.Motor 3 2 It can also be installed in wide spade when high static pressure is required, such as for offices. Bottom panel: 2 pieces The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed. Slim & Compact design In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270mm, Further space savings have been achieved by mounting the electrical control box internally inside the chassis. 1,200 Low energy consumption by high efficiency DC fan motor NEW Embedded in Ceiling The change of static pressure range is possible by remote controller Improved motor efficiency from previous model. 1,135mm Installation styles Easy setting by using remote controller NEW Two-direction drain piping Control box is now included as part of the main chassis 270mm Optional parts One touch operating and easy to install long life filter (Optional Parts) 24 model Dimensions Model name ARXA24GBLH ARXA30GBLH 7.1 ARXA36GBLH ARXA45GBLH 9.0 11.2 12.5 8.0 10.0 12.5 14.0 94 108 194 240 1,280 1,410 1,840 1,970 990 1,280 1,600 1,860 840 1,150 1,470 1,640 Power source 230V ~, 50Hz Cooling Remote Sensor Unit : UTY-XSZX Long Life Filter : UTD-LF25NA Flange (Square) : UTD-SF045T Duct indoor unit Two-direction drain piping 30 / 36 / 45 model Specifications Capacity Hanging from Ceiling Flange (Round) : UTD-RF204 IR Receiver Unit : UTB-YWC Drain Pump Unit : UTZ-PX1NBA (Unit : mm) Models: ARXA24 / ARXA30 / ARXA36 / ARXA45 *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size. kW Static pressure range Pa Standard static pressure Sound pressure level High Med dB(A) Low kg Weight 0 to 150 0 to 150 50 50 60 31 34 37 41 27 32 35 38 23 29 33 36 36 Gas (Flare) 264 264 82 ø205 hole Note : Specifications are based on the following conditions. ø15.88 75 168 1 3 2 P.C.D. ø225 40 121 ø9.52 mm 3 240 281 264 Front view 270 x 1,135 x 700 Liquid (Flare) Drain 24 0 to 150 40 mm Dimensions (H x W x D) Connection pipe diameter 0 to 150 138 ø200 (knock out hole) 700 m 3/h Low 447(Bolt pitch) Med 114 66 32 1177(Bolt pitch) Outlet 270 32 173 High 161 Airflow rate 240 W Input power 138 Heating 1015 1135 107 240 270 Top view ø19.05 Side view (R) Side view (L) ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. 1 Refrigerant piping flare connection (Liquid) : 2 Refrigerant piping flare connection (Gas) : 3 Drain piping connection (Drain pipe) Rear view 25 INDOOR UNITS High Static Pressure Duct Models Low noise ARXC36GATH ARXC45GATH Models : ARXC36 / ARXC45 Design also corresponding to high static pressure Cutting off the corners of the conventional indoor unit front panel and fan casing, has enabled less turbulent air flow. Low noise is realized by adopting a plastic case and a plastic fan. These indoor units allow for high airflow quantities ARXC36GATH ARXC45GATH Previous model Max. 250Pa New model (ARXC36GATH) ARXC36GATH : Plastic fan [45dB(A)] * Model : Material (At 100Pa : Actual noise measurement value) 500mm Easy installation (Compact size & Lightweight) Models : ARXC36 1,050 Volume 47.5% down Heat exchanger Weight 42% down 400mm A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight. 500 Plastic fan ø225mm 400 ARXC36GATH : 43kg (unit: mm) Specifications ARXC36GATH Power source High Med m3/ h Low Static pressure range Pa Standard static pressure High Med dB(A) 14.0 405 715 2,600 3,500 1,950 3,000 1,450 2,460 100 to 200 100 to 250 100 100 45 49 38 45 mm kg Weight Gas 400 324 108 88 Rear view 1 2 3 71 4 295 42 Side view (L) 400 x 1,050 x 500 43 14 371 356 208 1,080(Bolt pitch) 1,000 862 851 1,050 Top view Side view (R) 85 46 ø9.52 (Flare) Liquid mm Drain Note : Specifications are based on the following conditions. 26 12.5 12.5 32 Low Dimensions (H x W x D) Connection pipe diameter 11.2 41 123 139 kW W Input power Sound pressure level Models: ARXC36 / ARXC45 230V ~, 50Hz Cooling Heating Airflow rate (Unit : mm) 585 500(Bolt pitch) Capacity ARXC45GATH Long-Life Filter : UTD-LF60KA IR Receiver Unit : UTB-YWC Remote Sensor Unit : UTY-XSZX Casing (Plastic) Dimensions Model name Optional parts ø19.05 (Flare) ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. 1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection Front view 27 INDOOR UNITS Floor / Ceiling Models AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH Double auto swing Super vane A combination of up/down and right/left directional swing allows three-dimensional air direction control. Double Louvre Super vane with newly developed special configuration boosts airflow sending cool air quickly to every corner of the room. RIGHT and LEFT SWING The slim and lightweight design allow the unit to be suspended from the ceiling or installed on the floor. This type suits many room designs 2 UP and DOWN SWING 3 1 4 1 5 Auto-closing louvre 2 Floor standing 3 When operation is stopped, the louvres will automatically close. (This function is available on all non-ducted models.) 4 5 steps selectable 4 steps selectable Compact design Symmetrical, slim and compact design. High power DC fan motor Flexible installation Example for floor installation Example for ceiling installation Floor console Under ceiling • High power • Wide rotation range • High efficiency 655 990 Specifications Dimensions Model name AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH 3.6 4.5 5.6 7.1 4.0 5.0 6.3 8.0 30 42 74 99 660 780 1,000 1,000 Power source Capacity kW W Input power High Med Sound pressure level m3/ h 570 640 720 820 Low 490 550 580 680 High 36 40 46 47 32 36 39 42 28 34 35 37 Med dB(A) Low mm Dimensions (H x W x D) kg Weight Connection pipe diameter (Unit : mm) (Unit : mm) Models: AB*A12 / AB*A14 / AB*A18 / AB*A24 230V ~, 50Hz Cooling Heating Airflow rate 199 Liquid (Flare) Gas (Flare) mm 199 x 990 x 655 25 26 27 26 ø6.35 ø9.52 ø12.70 ø15.88 Drain 2 1 ø25 (I.D.) ; ø32 (O.D.) 2 1 AB*: ABY(FUJITSU), ABH(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection 3 28 3 29 INDOOR UNITS Ceiling Models AB*A30GATH AB*A36GATH AB*A45GATH AB*A54GATH Double auto swing and wide airflow High lift drain pump Auto airflow direction and auto swing Optional drain pump unit allows flexible installation design. Right and left Easily concealed in any installation Max. 500mm Fresh air intake 5 steps selectable Up and down Fresh air 1 Indoor 2 Outdoor 3 4 High power DC fan motor 4 steps selectable Installation • High power • Wide rotation range • High efficiency Long airflow Open Concealed Long Airflow ensures comfort to every corner of a large room. Wall mounted (Field Supplied) Long-life filter -flow e air tanc dis ong High Efficiency long-life filter doubles the life of the filter compared to standard filters. L General installation pattern which suspends the indoor unit from the ceiling. Installation pattern where part of the indoor unit is embedded into the ceiling. Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient. Specifications Dimensions AB*A30GATH Model name AB*A36GATH Power source Capacity Cooling kW W Input power High Med Sound pressure level AB*A54GATH m3/ h 9.0 11.2 12.5 14.0 10.0 12.5 14.0 16.0 66 85 131 180 1,630 1,690 2,010 2,270 1,370 1,400 1,600 1,780 Low 1,140 1,170 1,230 1,280 High 42 45 48 51 38 38 42 45 33 34 35 36 Med dB(A) Low mm Dimensions (H x W x D) kg Weight Connection pipe diameter AB*A45GATH Optional parts Hight Drain Pump Unit : UTR-DPB24T Flange : UTD-RF204 240mm (Unit : mm) Models: AB*A30 / AB*A36 / AB*A45 / AB*A54 230V ~, 50Hz Heating Airflow rate Slim & Compact design Liquid (Flare) Gas (Flare) mm 240 x 1,660 x 700 46 48 ø9.52 ø9.52 ø19.05 ø15.88 Drain AB*: ABY(FUJITSU), ABH(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. ø25 (I.D.) ; ø32 (O.D.) 1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 3 Drain piping connection 2 30 1 3 31 INDOOR UNITS Wall Mounted Models (EEV internal model) Models (EEV external model) AS*A07GACH AS*A09GACH AS*A12GACH AS*A14GACH AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH Compact size Width 790mm Powerful output even compact design Though the indoor unit is compact, it features a large, high pressure cross fan (90mm diameter) in a centre mounted configuration and a Lambda type heat exchanger to provide plenty of power. Auto swing louvre The Auto Swing Louvre function ensures that the air direction corresponds to the mode selected. 1 Compact and Stylish design indoor 2 ing Sw 3 4 Step Swing 790mm Filter features Deodorizing effect High quality air conditioning by incorporation of high performance filter. (Odor reduction rate) Trimethylamine Ammonia Long-life* Ion Deodorization Filter (ppm) (ppm) 160 160 With no filter 120 The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic. New filter 80 80 New filter 40 40 Easy maintenance • High power • Wide rotation range • High efficiency • Compact size Easy maintenance has been realized as the front panel can removed for easy access. Open panel 0 0 (*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.) With no filter 120 New style high power DC fan motor 30 0 60 120 (min) 0 30 60 120 (min) Hydrogen sulfate (ppm) Apple-catechin Filter 160 With no filter 120 New filter 80 Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. Testing organization : Environmental Sanitary Inspection Center Test method : Deodorization Test 40 0 0 30 60 120 (min) Specifications AS*A07GACH AS*A09GACH AS*A12GACH AS*A14GACH AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH Power source 230V ~, 50Hz Sound pressure level High Med dB(A) Low Dimensions (H x W x D) Weight Connection pipe diameter 3.6 4.5 2.8 3.2 4.1 5.0 2.8 3.2 4.1 5.0 17 18 22 34 15 16 21 34 490 500 560 670 490 500 560 680 450 450 480 490 450 450 480 490 370/420*1 370/420*1 420 420 370/420*1 370/420*1 420 420 35 36 39 44 34 35 38 43 33 33 35 37 32 32 34 35 27/31*1 27/31*1 31 32 26/30*1 26/30*1 30 30 790 mm 275 x 790 x 215 275 x 790 x 215 kg 9 9 Liquid (Flare) Gas (Flare) mm Drain EV Kit (option) AS*: ASY(FUJITSU), ASH(GENERAL) Note : Specifications are based on the following conditions. 32 ø6.35 ø6.35 ø12.70 ø12.70 ø13.8(I.D.) ; ø15.8-ø16.7(O.D.) - 215 470 3 530 660 1 EV kit (UTR-EV09XB/ UTR-EV14XB ) Optional parts: 2 ø13.8(I.D.) ; ø15.8-ø16.7(O.D.) UTR-EV09XB 416 222 UTR-EV14XB Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. *1 : This value is under cooling operation. 1 Refrigerant pipe flare connection (Liquid) 2 Refrigerant pipe flare connection (Gas) 3 Drain piping connection OUTDOOR UNIT SIDE 32 UPWARD 19 wire Install the unit as confiremed direction . Install the unit where it will not be tilted by more than 5° Horizontal installation INDOOR UNIT SIDE 65 97 121 Low 2.8 65 m 3/h 2.2 wire Med 4.5 Vertical installation High 3.6 UPWARD W Input power 2.8 Models: AS*A07 / AS*A09 / AS*A12 / AS*A14 AS*E07 / AS*E09 / AS*E12 / AS*E14 Install the unit as confirmed direction. Install the unit where it will not be tilted by more than 5° kW 230V ~, 50Hz 2.2 (Unit : mm) 275 Cooling Heating Airflow rate Symmetrical, clean design that suits all interiors. Dimensions Model name Capacity Symmetrical design 33 INDOOR UNITS Wall Mounted “Vertical airflow” provides powerful floor level heating Models AS*A18GACH AS*A24GACH AS*A30GACH Air conditioner filter features 5 (24/30) Ion Deodorization Filter 2.5 Simple & Elegant Appearance Design Organic coating fin used heat exchanger 0 3 6 9 12(m) (˚C) 46 o Outside air conditions: 2 ˚C 60% Operation contents: Heating, Set temperature (Max set temp) 30 ˚C, 33 airflow Hi, Air direction downward and front 32 31 30 29 Apple-catechin Filter Pre Filter Power diffuser (full open) “Horizontal airflow” does not blow cool air directly at the occupants in the room 5 Antibacterial deodorizing pre-filter with special ceramic powder Long-life* Ion Deodorization Filter (24/30) Compact & Slim design The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic. 2.5 By using DC fan motor, compact design is realized. New model 0 Previous model 3 6 9 (*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.) 12(m) (˚C) Power diffuser Outside air conditions: 35 ˚C 40% Operation contents: Cooling, Set temperature (Min set temp) 18 ˚C, airflow Hi, Air direction downward and front Using different filters at both sides 15 16 17 18 Apple-catechin Filter Easy maintenance 998mm Simplification of drain pan cleaning improves maintenance-ability. 1120mm DC fan motor Specifications Dimensions AS*A18GACH Model name Power source Capacity kW W Input power High Med m3/ h Low High Sound pressure level Med dB(A) Low 7.1 8.0 6.3 8.0 9.0 32 60 91 840 1,100 1,240 770 910 980 690 730 770 41 48 52 39 43 45 35 35 35 kg Weight Liquid (Flare) Gas (Flare) mm AS*: ASY(FUJITSU), ASH(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. 34 Models: AS*A18 / AS*A24 / AS*A30 320 520 320 x 998 x 228 15 ø9.52 Drain (Unit : mm) 998 5.6 mm Dimensions (H x W x D) Connection pipe diameter AS*A30GACH 230V ~, 50Hz Cooling Heating Airflow rate AS*A24GACH Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. 590 228 721 ø15.88 ø12 (I.D.) ; ø16 (O.D.) 520 1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain hose connection 35 CONTROLLER Control System Every user's needs are supported by offering a variety of controls, such as individual control, central control and building management control options. Building Management Air Conditioning Individual Control Air Conditioning Central Control System Controller Software UTY-APGX UTY-PEGX(Option) USB Adaptor *2 System Outdoor unit Wired Remote Controller (Touch panel) UTY-RNR* Internet or Public Telephone Line Indoor unit (Field supplied) R*:RY(FUJITSU), RG(GENERAL) Outdoor unit Wired Remote Controller Remote / Monitoring side UTY-RNK* Indoor unit Touch Panel Controller K*:KY(FUJITSU), KG(GENERAL) UTY-DTG* Simple Remote Controller UTY-RSK* G*:GY(FUJITSU), GG(GENERAL) Central Remote Controller K*:KY(FUJITSU), KG(GENERAL) UTY-DCG* General-purpose Building Control Computer Signal Amplifier UTY-RHK* UTY-VSGXZ1 Without operation mode G*:GY(FUJITSU), GG(GENERAL) Group Remote Controller Connectable to various sized BMS/BAS *1 Simple Remote Controller Network Convertor K*:KY(FUJITSU), KG(GENERAL) UTY-VGGXZ1 UTY-CGG* Wireless Remote Controller IR Receiver Unit UTY-LNH* UTB-YWC G*:GY(FUJITSU), GG(GENERAL) BACnet ® Gateway Software H*: HY(FUJITSU), HG(GENERAL) UTY-ABGX USB Adaptor *2 IR Receiver Unit UTY-LRH*B1 (Field supplied) or Card-key Network Convertor (BMS / LONWORKS®) External Switch Controller *B:YB(FUJITSU), GB(GENERAL) For single split UTY-TEKX UTY-VLGX Network Convertor (Field supplied) Web Monitoring Tool Service Tool Software Internet or Public Telephone Line The devices above cannot be connected to the S series. (Except System Controller & BACnet® Gateway) 36 (Monitoring side) (VRF system side) Software SU MO TU WE TH FR SA 7 SU MO TU WE TH FR SA 7 3 6 9 12 15 18 21 3 6 9 12 15 18 21 UTY-ASGX UTY-AMGX *1. BMS/BAS: Building Management System / Building Automation System *2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation. UTY-VGGXZ1 USB Adaptor *2 USB Adaptor *2 (Field supplied) (Field supplied) Transmission line (VRF Network) LONWORKS ® Network Remote controller line (2 wires) Ethernet Remote controller line (3 wires) Signal line(Single split system) USB cable Group Remote Controller line 37 CONTROLLER Wiring system Max. transmission line length • Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring. • Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers). Comparison table of Controllers 3,600m Item System Controller UTY-APGX Maximum 1,600 indoor units can be controlled. Air conditioning control Operation monitoring Status monitoring system Electricity charge calculation USB Adaptor NW 1 Internet or Public Telephone Line NW 2 NW 3 NW 4 Model name (Remote / Monitoring side) Touch Panel Controller One Touch Panel Controller can control up to 400 groups / 400 indoor units. Group Remote Controller Maximum 8 remote controller groups can be controlled BACnet Gateway UTY-ABGX ® IR Receiver Kit Cassette type indoor unit can be controlled with Wireless Remote Controller USB Adaptor Remote Controller line Maximum 16 units can be controlled BACnet ® Network Convertor for LONWORKS® UTY-VLGX BACnet ® Operator Workstation (B-OWS) System without Remote Controller Together with Touch Panel Controller, it is possible to build non remote controller system. Web Monitoring Tool Trouble free operation at all times by remote monitoring system. UTY-DTGG 1 8 100 400 1600 18 100 400 1600 Max. controllable groups - - - - - - 16 400 1600 - - - - - - - - Display External Switch Controller Indoor units can be controlled by combining with Card-key switch such as hotel room. Network Convertor UTY-VGGXZ1 - Operation mode setting Fan speed setting Room temp. setting - Room temp. set point limitation Up/down air direction flap setting Touch Panel Controller Remote Controller line (2 wires) Central Remote Controller Simple Remote Controller IR Receiver unit Remote Controller line (3 wires) USB cable Indoor unit (Duct) Group Simple Remote Controller Remote Controller System Controller Wireless Wired Remote Controller Remote Controller (Touch panel) LONWORKS® Network Ethernet Signal line (single system) Group Remote Controller line - - - - - - - - - - RC prohibition - - - - - - - Anti freeze setting - - - - - - - Setback cool/heat - - - - - - Economy mode setting - - - - - Failure - - - - - Defrosting - - - - - Current time - - - - - Day of week - - - - - R.C. prohibition - - - - - Cooling/heating priority - - - - - Address display - - - - - Room temp - - - - - - Multi language - - - - - - - - - - - - - - - - - - - - On/Off, Temp, - - - - - - - - - Week Week - - - Week Week Year Year 8 4 - - - 4 20 20 144 - - - - - - - - On/off timer Sleep timer - - - - - - - - - Program timer - - - - - - - - - Auto off timer - - - - - - - - Day off - - - - - 10 30 ● 30 - - 5 10 10 10 10 Status monitoring system - - - - - - Electricity charge calculation - - - - - - - - Emergency stop - - - - - - Control via internet - - - - - - - - E-mail notification for malfunction - - - - - - - - - - - - Child lock Password setting Password setting - Error history Control Indoor unit (Cassette) - - Min. unit of timer setting (Minutes) Module link - - mode, times per day Timer Wired External Switch Remote Controller Controller - - Summer time Transmission line - - Single system Service Tool Extensive monitoring and analysis functions for installation and maintenance. - Group setting Right/left air direction flap setting Schedule timer Big Multi system - Test operation Backlight Outdoor unit UTY-APGX 16 USB Adaptor 38 UTY-DTGY UTY-DCGG 1 Period (Monitoring side) UTY-DCGY UTY-CGGG 16 (VRF network system side) (Monitoring side) UTY-CGGY UTY-LNHG 1 Name registration Service Tool UTY-ASGX (Monitoring side) UTY-LNHY UTY-RHKG 16 IR Receiver Unit Duct type indoor unit can be controlled with Wireless Remote Controller. Network Convertor UTY-VGGXZ1 Internet or Public Telephone Line UTY-RHKY UTY-RSKG 1 USB Adaptor Web Monitoring Tool UTY-AMGX UTY-RSKY UTY-RNKG 16 Transmission line line is non-polar 2-conductor. Signal Amplifier UTY-VSGX UTY-RNKY UTY-RNRG Software 1 Card key 2 Remote Controllers Indoor unit can be controlled from both remote controllers. UTY-RNRY System Controller 16 LONWORKS® LONWORKS® Network Touch Panel Controller Max. controllable indoor units Air conditioning control function BACnet Simple Remote Simple Remote*1 Wireless Remote Group Remote Central Remote Controller Controller Controller Controller Controller On / Off Network Convertor UTY-VGGXZ1 ® Wired Remote Controller Max. controllable remote controller groups Central Remote Controller Maximum 100 indoor units can be controlled. Building Management System Wired Remote Controller (Touch panel) Key lock Child lock *1 "Operation mode" setting is not available for this model. *2 This function is available only through external input. control. *2 ● : Supported *2 — : Not supported yet - Password setting ○ : Supported soon 39 CONTROLLER Wired Remote Controller (Touch Panel) Max. transmission controllable Max. line length 16 indoor units UTY-RNR* Various convenient functions Setback-Cool / Setback-Heat (Future release) ・Cooling / Heating is automatically started when the room temperature reaches a setting temperature even if the indoor unit is off. Easy operation by high-definition large STN-LCD touch panel screen In summer • Easy finger touch operation with LCD panel • Built-in weekly/Daily timer(ON/OFF,Temp.,Mode) • Backlight enables easy operation in a darkened room • Room temperature display • Control up to 16 indoor units • Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish) In winter Setting temp. Room temp. Setting temp. Setback-Heat function operation Setback-Heat function set Setback-Cool function operation Automatically start Automatically stop Setback-Cool function set Automatically start Automatically stop Displays setting status and Limitations • The remote controller settings can be easily checked Functions High performance and compact size Various energy saving control • In addition to the individual control, various energy saving controls can be realized using one remote controller only. Auto OFF Timer • The indoor unit automatically turns off after a set time has passed. • The time interval for which auto off works can be set. Individual control Ex) At interval time hour (17:00 to 24:00)to prevent forgetting to turn off Thermo sensor Room temp. Weekly timer Auto off timer Child lock • Lock / unlock method: Push the ON/OFF button and the screen (4 seconds) Set interval time hour (17:00 to 24:00) ON Auto OFF Summer Time display • This function can be set easily from Menu screen Set off time (30 to 240 minutes) OFF 17:00 Accurate and comfortable control • Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. 24:00 Name Registration • Indoor unit names can be registered in the remote controller screen. This makes it easy to identify the indoor unit you want to control in the room. 2 schedules Weekly Timer • 2 schedules such as for the summer and winter can be set. • 8 setting changeable per day of week (Setting items: On/Off, Temperature, Mode, Time) Ex) Simplified installation Schedule 1 (Summer schedule) Setting temp. 26°C ON OFF Uses non-polar 2-wire type • The faulty wiring can be prevented by using non-polar 2-wire. Schedule 2 (Winter schedule) Setting temp. OFF 25°C 24°C OFF ON OFF I.U. I.U. Y1Y2 Y3 non-polar 2-wire 23°C OK 8:40 11:40 17:30 20:40 Time 8:40 10:00 15:30 17:30 20:40 Address → Y1 Backlight • Backlight enable easy operation in a darkened room. • For the lighting time of Backlight, 30 or 60 seconds can be set. • Backlight activates while the buttons are operated and goes off 30 or 60 seconds after the operation stops. 23°C Settable time range 10 to 120 minutes Settable time range 10 to 120 minutes 02 01 Time 11:40 13:40 Time Error History Display • The errors that occur in the indoor unit or remote controller are saved as a history. • A maximum of 32 error incidents can be saved. Set Temperature Upper and Lower Limit Setting • The set temperature range can be set for each operation mode. (Cooling / Heating / Auto) During Cooling 30°C During Heating Specifications 30°C UTY-RNR* Model name 25°C 25°C DC 12V Power Supply Dimensions (H x W x D) (mm) 18°C Original temp. setting range Lower limit setting 10°C Original temp. setting range Upper limit setting 120 x 120 x 20.4 220 Weight (g) DC12V is supplied by the indoor unit. 40 03 Easy Maintenance 25°C 13:40 04 Y2 05 22°C 11:40 Y1 The appropriate indoor unit performs the air blow and LED lamps blink. Setting temp. Set temperature change Auto return 24°C Room temperature display Y2 Heating operation Setting temp. Set temperature change Auto return Room temperature sensor OK Auto Address Setting/Setting Position Notification • Reduce errors and install time compared with the current specification Rotary SW • When will be set remote controller groups, can also be set automatically new Wired remote controller address • After auto address setting of new wired remote controller groups, what number can also confirm addresses Time Set Temperature Auto Return • The setting temperature automatically returns to the previous setting temperature. • The time range in which the set temperature can be changed is 10 to 120 minutes. Cooling operation Y1Y2 Y3 R* : RY(FUJITSU), RG(GENERAL) 41 CONTROLLER Wired Remote Controller Max. controllable 16 indoor units UTY-RNK* Simple Remote Controller Max. controllable 16 indoor units UTY-RSK* UTY-RHK* (Without Operation mode) The room temperature can be controlled by detecting the temperature accurately from the built-in sensor Compact remote controller provides access to basic functions • Simple operation with Built-in Weekly / Daily Timer. • Control up to 16 indoor units. • Up to 2 wired remote controllers can be connected to a single indoor unit. • Up to 16 indoor units can be controlled with one remote controller. • Suitable for hotels or offices as it is easily operated with no complex functions. UTY-RSK* Functions Functions Powerful features and compact size Built-in timers This Wired Remote Controller incorporates four primary functions into a single unit. Weekly timer : Possible to set ON/OFF time to operate twice each day of the week. Individual control Thermo sensor UTY-RHK* Without Operation mode Weekly timer Easy-to-understand time bar display Setup screen example Set to Wednesday: 8:00 to 20:00. Setback timer 0 3 6 9 12 24°C 15 18 Screen after setup 21 Time User-friendly operation Backlight • Provides access to basic operations, such as Start / Stop, Fan control, Operation mode switching, and Room temperature setting. • A large On / Off button is provided in the centre of the remote controller for easy operation. • Can be used jointly with other individual control unit. • Following an error display, diagnostics can be carried out on the controller. • Backlight enables easy operation in a darkened room. • Backlight activates during all button operations, and lasts 10 seconds in Operation mode and 5 seconds in stop mode after a button is pressed. Simple installation Functions summary Setback timer : Possible to set temperature for two times spans and for each day of the week. Accurate and comfortable Setup screen example Set from Sunday to Saturday: 12:00 to 15:00, 28°C. Sensor part Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. This new wired remote controller and the optional remote sensor allows flexibility in sensor location, suitable for all requirements. Thermo sensor display Control part for changing the thermo sensor 0 3 6 9 28°C 15 18 12 Can be mounted on the European Mounting Box (Installation dimension: 60mm) or the JIS Built-in Box (Installation dimension: 83.5mm). 21 Time At "Weekly timer" + "Set back timer" setup 3 6 9 24°C 12 15 18 21 28°C Operation 24°C Time Diagnosis check function Example of changing sensor Indoor unit Day UTY-RHK* European switch box Fan control *1 Operation mode Room temp. setting JIS built-in box *1: "Operation mode" setting is not available. It is recommend to use together with other type controller. Two methods are available for determining the cause of failure in the event of a malfunction occurs: Remote Sensor in the bedroom UTY-RSK* On / Off 83.5mm 0 60mm 28°C 24°C Model • Malfunction diagnosis function • Error history (Last 16 error codes can be accessed) Night Wired remote controller Remote sensor The detecting point can be easily changed Wired Remote Controller in the living room Simple installation Components are compatible with standard switch boxes. Flat back surface allows to be installed wherever it is needed. European mounting box JIS built-in box Displayed temperature is set temperature. Specifications Model name Power Supply Dimensions (H x W x D) (mm) Weight (g) DC12V is supplied by the indoor unit. K* : KY(FUJITSU), KG(GENERAL) 42 Specifications UTY-RNK* DC 12V 120 x 120 x 18 160 Model name UTY-RSK* DC 12V Power Supply Dimensions (H x W x D) (mm) 120 x 75 x 14 90 Weight (g) DC12V is supplied by the indoor unit. UTY-RHK* 90 K* : KY(FUJITSU), KG(GENERAL) 43 CONTROLLER Wireless Remote Controller Max. controllable 16 indoor units UTY-LNH* IR Receiver Unit UTB-YWC Selectable 4 Simple and sophisticated operations with a choice of 4 daily timers daily timers Necessary to control for all duct type by Wireless Remote Controller • A single controller controls up to 16 indoor units. Functions Wiring connection Built-in daily timer Easy installation and operation Select from 4 different timer programs : On / Off / Program / Sleep Program timer : The program timer operates the ON and OFF timer once within a 24 hour period. Sleep timer : The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours. Code selector switch prevents indoor unit mix-up. (Up to 4 codes can be set.) Duct Type Indoor Unit IR Receiver Unit Wireless Remote Controller Specifications Wide and precise Cooling operation/dry operation Model name When the sleep timer is set, the set temperature automatically rises 1˚C every hour. The set temperature can rise up to a maximum of 2˚C. Battery Dimensions (H x W x D) (mm) T imer setting Weight (g) UTB-YWC DC 12V 145 x 90 x 30 150 60min. 2˚C 1˚C Address setting During installation work, address setting can be performed using the Wireless Remote Controller, thus eliminating manual switch setting. Heating operation When the sleep timer is set, the set temperature automatically drops 1˚C every 30 minutes. The set temperature can drop to a max. of 4˚C. 1˚C 2˚C Transmission line Outdoor unit 3˚C Indoor unit 4˚C IR Receiver Unit UTY-LRH*B1 Cassette type indoor unit can be controlled with Wireless Remote Controller Wireless Remote Controller 30min. 60min. 90min. Timer setting Wireless Remote Controller Specifications Specifications Model name Battery Dimensions (H x W x D) (mm) Weight (g) H* : HY(FUJITSU), HG(GENERAL) 44 UTY-LNH* 1.5V (R03 / LR03 / AAA) x 2 170 x 56 x 19 85 Model name Battery Dimensions (H x W x D) (mm) Weight (g) UTY-LRH*B1 DC 12V 193.9 x 193.9 x 31.2 140 H* : YB(FUJITSU), GB(GENERAL) 45 CONTROLLER Group Remote Controller Max. controllable UTY-CGG* remote controller groups 8 Useful functions Max. connectable 64 Group control of indoor units with simple operation group R.C. in a VRF network system • Up to 8 remote controller groups can be controlled by one Group Remote Controller. • Up to 64 Group Remote Controllers can be connected in one VRF network system. • Network Convertor (UTY-VGGXZ1) is required to connect Group Remote Controllers to a VRF network system. (Network Convertor allows up to 4 Group Remote Controllers) Indoor Unit Operation Indicators 1 Timer setting at all the connected indoor units is possible by centralized timer on the front panel. Timer setting at all the connected indoor units is possible by centralized timer on the front panel. With cover closed : On : Timer operation 2 All the connected indoor Press the ALL TIMER button to turn the timer operation on or off for all indoor units. units can be turned on / off simultaneously by centralized ON/OFF button on the front of the cover. Functions 3 The indoor unit can be quickly Central control ON/OFF control Operation Lamp turned on and off by ON / OFF button of each indoor unit on the front of the door. High performance and compact size ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually. : Off : Selection ALL TIMER Button Weekly timer Control up to 8 remote controller groups Single Group Remote Controller controls and monitors up to 8 remote controller groups. This is on if any of the indoor units is operating. This flashes if any of the indoor units has malfunction(s). Indoor Unit Name Labels ALL OFF Button Write the names of the indoor units on the included labels and attach them. Press the ALL OFF button to turn off all of the indoor units. ON / OFF Button ALL ON Button Press the ON / OFF button to turn the corresponding indoor unit on or off. Press the ALL ON button to turn on all of the indoor units. With cover open Timer and Clock Display and setting Displaying the Status and Controlling indoor units Setting Display Hotel Transmission Display Operation Lock Display Day Display Guest room ON / OFF Display Timer and Clock Display Fan Speed Display Timer Mode Display Office room Office & Lounge Set Temperature Display Lounge Operation Mode Display Timer Mode (DELETE) Button ON / OFF Button DAY Button Select Button Restaurant Restaurant Network Convertor Fan Control Button Set Time Button Master Control Button*1, *2, *3 PROGRAM (CLOCK ADJUST) Button Lobby Set Temperature Button Lobby ENTER Button 1 Child Lock Function Group Remote Controller 1 To control office room, lounge, restaurant and lobby (8 remote controller groups) 2 Group Remote Controller Group Remote Controller 2 To control guest room and lounge (7 remote controller groups) " is not available for a heat pump model unless it is set up for the master indoor unit. * 1 : "AUTO * 2 : "FAN " is not available for a heat pump model " is not available for a cooling only model * 3 : "HEAT Built-in weekly timers The weekly timer is provided as a standard function. 1. The timer can be set up for up to 4 times per day. (On / Off, operating mode, set temperature) 2. Allows separate settings for each day of the week. Time Air conditioning ON/OFF setting corresponding to air conditioning specification needs is possible. Temperature switching (Peak power cut) (Anti-freeze) Time Switching between the cooling mode and heating mode can be set by time. Ope. Time Since peak power cut is performed in a planned way, setting which changes the room temperature linked with time is possible. Stop setting Specifications Ope. Temperature switching Ope. Ope. Cooling / Heating switching Ope. ON / OFF switching Low temperature heating operation can be set to prevent freezing in cold regions at night, etc. Time Indoor unit stop setting at operation end time is possible. Power Supply DC 12V Dimensions (H x W x D) (mm) 120 x 120 x 18 200 Weight (g) DC12V is supplied by a network converter. 46 UTY-CGG* Model name Time G* : GY(FUJITSU), GG(GENERAL) 47 CONTROLLER Central Remote Controller Max. controllable 100 Indoor units UTY-DCG* Max. controllable Central control of small- and medium-sized buildings and tenants. The operation status of all connected indoor units can be viewed at a glance on a large LCD monitor to simplify individual control to batched control. 16 groups • Individual control and monitor of 100 indoor units • 5 inch TFT color screen • User friendly view and easy operation • External input / output contact • Detachable power supply unit • Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish) Functions Diverse control of indoor units • Weekly timer : Weekly timer can set the timer by various combinations. • Individual control (On / Off, Mode, set Temp, Fan speed, Economy operation, Antifreeze operation) Set temp. Weekend 26°C 26°C 26°C 28°C 28°C 28°C Holiday 8:00 User friendly operation Operation status monitor displays for all indoor units Easy comprehensible display and operation button 28°C 26°C Weekday • Remote controller prohibition (All, On / Off, R.C prohibition setting prohibits individual remote control operation from this controller Function menu displays the items to select. 21:00 Time Error history • Room temperature set point upper and lower limitation Registration indoor unit 18:00 • Automatic clock adjustment : The time setting of each controller can be set in batch automatically. Mode, Temp, Timer, Filter) : Function Menu 12:00 13:00 • Max 200 Errors memorize. • Suitable maintenance is possible by analysis of the error history data. Function button 1 to 1 function button supports easy setting. Operation guidance Easy Installation • The control panel and power supply unit can be installed separately. • For flexibility in installation, the Control panel can be built into the wall or fix on the wall. Setting pattern 1 Ceiling Power supply unit Wall Group : 3F Wall Indoor unit registration finish Group : Division C Specifications Group : Tenant B Group : Tenant C UTY-DCG* Model name Power Supply Dimensions (H x W x D) (mm) Weight (g) Emergency stop function Control panel Control panel + Power supply unit Group : Division B Group : 2F Group : Tenant A Indoor unit registration start SW BOX Group : Hallway Group : Division A Indoor unit registration Setting pattern 2 System overview • It allows multiple indoor units grouping (Max.16 groups controlled) • Interlock with external device • Automatic or manual indoor unit registration Control Panel Power Supply Unit DC 5 V 100-240V, 50-60Hz, Single phase 120 x 162 x 25.7 99 x 135 x 39.2 308 355 Packing List Control Panel / Power Supply Unit / Connecting cable, etc. G* : GY(FUJITSU), GG(GENERAL) 48 49 CONTROLLER Touch Panel Controller Max. controllable 400 Indoor units UTY-DTG* Up to 400 indoor units can be controlled High visibility and easy operation via high resolution 7.5 inch TFT-LCD touch panel screen Group A • Large-sized 7.5-inch TFT color • LCD Easy finger touch operation • Stylish shape and design to suit all application • No additional component is required for installation • Up to 400 indoor units can be controlled • Selectable 2 display types (Icon / List) in monitoring mode • Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish. Group B It allows multiple indoor unit grouping Emergency stop control Air conditioner can be turned off through the external input control Emergency stop function Functions Function Versatility • Up to 400 indoor units can be controlled • It allows multiple indoor units grouping • Schedule timer function is standard (20 patterns per day) • Emergency stop function(through the external input control) • Temperature upper and lower limit setting • The clock of each indoor unit correct setting CSV format data edited by PC can be imported to Touch Panel Controller. Individual control Flexible grouping Data transfer available by USB Easy installation Touch Panel Controller is easily mounted to the wall Flat back surface allows to be installed wherever it is needed. • Correctable mechanism for tilting (horizontal) after the installation of the body No additional component is required for installation • There is no need for the installation space of power supply adaptor and transmission adaptor etc. Schedule control Indoor units operation monitoring Automatic clock adjustment The time setting of each controller can be set in batch automatically. Real size screen image Easy operation Easy maintenance • Large and wide-angled LCD is easily viewable even at a distance • Easy-to-understand icon-driven Graphical User Interface (GUI) • Wide range of simple-to-understand icons • Flat touch screen is easily cleaned • Non-glare coating on touch panel controller minimizes fingerprint marking • Easy-to-remove front cover Specifications • Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate on-screen icon • Up-to-date status display • Background color identifies current control operation Blue for monitoring, green for operational control Model name Power Supply Dimensions (H x W x D) (mm) Weight (g) Interface UTY-DTG* 100-240V 50/60Hz, Single phase 260 x 246 x 54 2,150 USB 2.0 G* : GY(FUJITSU), GG(GENERAL) 50 51 CONTROLLER Max. controllable Software 4 VRF network systems UTY-APGX Max. controllable 400 System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings. Outdoor units • Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled. • Supports VRF S series, V series and V-ll series. • In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met. Max. controllable 1,600 Indoor units Functions User friendly view and operation • Click & Operate : The property is shown visually from the perspective most suitable for operation and operated accordingly (Click & Operate). You can select from among the 4 displays of site, building, floor, or list. Click & Operate the whole building ! • Freely define groups for batched control : Indoor units can be freely grouped for simple batched control from a tree menu. Grouping by hierarchal structure, such as by section, division or department is possible. Properties can be shown using one of the four displays of site, building, floor, or list. Click & Operate any specified unit(s)! Energy saving management Peak cut operation With UTY-PEGX Outdoor unit capacity save Option Option Option A power meter is connected to detect the total power consumption while shifting the indoor unit set temperature, set the indoor unit forced thermostat off, and taking other measures to carefully control the power Outdoor unit Forced thermostat Target power consumed while stop range off range consumption maintaining comfort and conducting control to maintain the target power consumption set for each time. The indoor units to be controlled can be freely grouped and the control Shows change in power Ideal control line (Use of level can be set. consumption by time average power consumption) Outdoor unit capacity save switches the outdoor unit capability upper limit to suppress power consumption during hot summers and cold winters by averaging the power saving effect of each refrigerant system. You can select from 50% or more of the capacity upper limit. Indoor unit rotation operation Batched stop Option The operation of indoor units can be automatically rotated within a group in accordance with the set annual schedule to reduce power consumption while maintaining comfort. The indoor unit operation stoppage rate can be selected. Outdoor unit capacity upper limit Power consumption System Controller Time Outdoor unit capacity control screen Batched stop at a freely set time for a property, building, or freely set block unit can be done to prevent any air conditioning unit from being forgotten to be turned off at the end of office hours, etc. In addition, any air conditioning unit whose operation is left on can be immediately identified by the icon color for a building or indoor unit in the monitoring screen and batched stop conducted in response. The display is easily changed by pressing the button. Batched stop Forget to turn off Entire building stopped Indoor unit rotation screen Site view List view Electricity charge apportionment Electricity charge apportionment calculation framework Suppose you want to find the power consumed by the air conditioners of each tenant from the electricity charge for each month. With electricity charge apportionment function, used energy apportionment ratio will be provided, calculating in detail the energy consumed by the units used by each tenant. This information is then used to calculate the charges for the electricity consumed for air conditioning by each tenant from the total electricity charges in the bill from the electric power company. (See figure at right) The detailed calculation takes into consideration such things as unused rooms and nighttime electricity charges and shows them in a charges calculation sheet. Batched control of freely defined groups Energy used by each unit is calculated Energy apportioned by the outdoor unit to each indoor unit is calculated Tenant A Tenant A Tenant B Tenant C Tenant B Tenant C System Configuration Example Building view Electric power company Batched control of freely selected units Electricity charges (air conditioning) Signal transmission line System Controller P r Powe Pow distribu ibu butio tion boardd Outdoor unit Click & Operate the whole floor ! The floor layout drawing can be imported to easily make the settings for the actual building. Tenant A-1 Tenant A-2 Tenant A-3 Tenant A-4 Tenant A-5 Tenant A-6 P r Powe Pow distribu ibu butio tion boardd Electricity charges by tenant are calculated The distribution ratio for energy used by each indoor unit is calculated and the electricity charges for the energy used by each indoor unit are calculated from the total electricity charges. The energy used by each indoor unit and the energy apportioned by the outdoor unit are added together to calculate the total amount of energy used. Indoor unit energy used Tenant B-1 Tenant B-2 Tenant B-3 Tenant A Tenant B Tenant C Electric Bill Electric Bill Electric Bill Apportioned energy Indoor unit total energy used 3Ø, 4 wire 400V, 50Hz Tenant C-1 Tenant C-2 Tenant C-3 1Ø, 2wire 230V, 50Hz Floor view Click & Operate the unit ! 52 53 CONTROLLER Remote centralized control System Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and communicate with VRF system. VRF Explorer runs remotely and provides user interface and communicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a single PC or in different PCs separated by network. By using VRF Explorer software, one PC can perform central control of 10 VRF system sites with max. 20 buildings per site. Remote central control 1 VRF Explorer can control or monitor up to 10 sites. VRF Explorer Building management company, management center, etc. VRF Controller A maximum of 10 locations, such as offices or factories Schedule control Error display & E-mail notification • Annual schedules can be set for each remote controller group / user defined group. • Start / stop, operating mode, remote controller prohibition, and temperature settings can be set up to 144 times per day at 10 minute intervals for up to 101 configurations for each remote controller group. • Settings can be made for periods straddling midnight. • Allows programming of special settings for holidays, including public holidays, for a complete year. • Low noise operation of outdoor unit can be scheduled. Error is notified with popup message, audible sound and E-mail real time when error occurs. Error for the past 1 year are logged and can be reviewed later. VRF Controller On site central control Internet or Telephone Line or LAN Max. 4 VRF network systems per site Operating & control record Displays the history of operation status and control. Internet or Telephone Line or LAN 1 VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously). VRF Explorer Central Monitoring Screen for all Properties VRF Explorer Building Management Company A (In charge of the day shift) VRF Explorer VRF Explorer Building Management Company B (In charge of the night shift) Internet or Telephone Line or LAN Office Management Center VRF Explorer VRF Controller Diverse control of indoor units • Indoor unit operation state, operation mode, etc. are displayed • Indoor unit start / stop and operation mode switching • Temperature setting, Remote Controller prohibition. VRF Explorer Prohibition Setting This prohibits changes to the operation mode, temperature, start / stop, etc. Multiple language display Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish) Security Company Headquarters Management Center The following chart shows the detail requirement for an AT compatible personal computer to run System Controller. Applies for both VRF Controller and VRF Explorer PC. Special Property Detailed Monitoring Screen Can be used for a variety of applications • Microsoft ® Windows ® XP SP3 (32-bit) Professional (*1) • Microsoft ® Windows ® Vista ® SP2 (32-bit) Home Premium, Business (*2) • Microsoft ® Windows ® 7 SP1 (32/64-bit) Home Premium, Professional (*2) [Supported languages] (*1) English only (*2) English, Chinese, French, German, Russian, Spanish, and Polish Operating system Air conditioning management for large shopping malls or the outlets of nationwide franchises Air conditioning management of multiple buildings spread over a large site Provides high-quality building air conditioning service • Remote centralized management can be used for nighttime only to manage the air conditioning of multiple stores, operate air conditioning for people working overtime, and checking to see if employees forgot to turn off the air conditioning after they leave. • Batched operation of the factory buildings on a large site can be remotely conducted from the management office of the administration building to employ power saving operation. • Service companies that manage buildings that are empty at night after the managers leave to go home can conduct centralized remote monitoring of the building without dispatching employees to the site, which allows them to monitor the air conditioning for multiple clients. CPU Intel® CoreTM i3 2GHz or higher Memory 2GB or more (Windows® XP, Vista®, 7 32-bit), 4GB or more (Windows® 7 64-bit) HDD 40GB or more of free space • The System Controller remote monitoring and control functions can be used to receive outsourcing business from small and medium size building owners to manage their air conditioning energy. Display 1024 x 768 or higher resolution • Nighttime only remote monitoring of multiple properties after the people leave can be performed for areas that require 24-hour operation, such as server rooms, to monitor for Service Companies problems. Interface USB port is required for each of the followings for Server PC ; • Wibu Key (Software protection key) • Echelon® U10 USB Network Interface (Required for each VRF Network) Ethernet port is required for remote connection using internet. Accelerator Requires the internal graphics accelerator be compatible with Microsoft® DirectX® 9.0 Software required Adobe ® Reader® 9.0 or later Hardware required DVD-ROM Drive • Multiple users via a LAN can control the air conditioning in the office, general affairs department, or janitor’s room. • The air conditioning for franchise locations nationwide can be centrally controlled from headquarters to facilitate operation status and control to save energy. Commercial buildings Franchises Security Support • The headquarters can conduct centralized remote monitoring of the company’s factories in outlying areas to improve the power saving effect for the entire company. • Controlling the operation of each building and each classroom on campus makes it possible to reduce expenses by remotely controlling those spaces in accordance with the teaching schedule. Factories Universities Hospitals