Meeting Various Needs with the FUJITSU GENERAL VRF AIRSTAGE Series
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/
ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101
Fujitsu General (Thailand) Co., Ltd.
ISO 9001 Certified number : 01 100 79269
ISO 14001 Certified number : 310102-UK
Fujitsu General (Shanghai) Co., Ltd.
ISO 9001 Certified number : 00608Q11061R2M
ISO 14001 Certified number : 00609E20454R2M
Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas. *Echelon ®, LONWORKS ®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. *BACnet ® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE). The colors may be different from the actual colors because this catalog is printed matter. Product specifications are subject to change without notice. Distributed by :
Copyright© 2011 Fujitsu General Limited. All rights reserved. 6NNJ24-1212E
The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only energy savings and comfort but also ease of design, installation, and maintenance. Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses.
OU UTDOOR UNITS
Small Office
Various Line-up for each buildings 4HP 5HP 6HP
AJ*A40LALH AJ*A45LALH
Large Homes
AJ*A54LALH
AJ* : AJY (FUJITSU), AJH (GENERAL)
Building owners
Installers
End users
Service and Management companies
Wide lineup of indoor units and controllers to support a variety of properties. INDOOR UNITS
CONTROLLERS
Central Controller
02
Compact Cassette
Cassette
Low Static Pressure Duct
Slim Duct (Drain Pump internal)
Medium Static Pressure Duct
High Static Pressure Duct
Floor / Ceiling
Ceiling
Wall Mounted (EEV internal / EEV external)
Wall Mounted
Central Remote Controller
Individual Controller
Group Remote Controller
Touch Panel Controller
System Controller (Software)
Wireless Remote Controller
Simple Remote Controller
Wired Remote Controller
Wired Remote Controller (Touch Panel)
03
FEATURES
High Energy Saving Efficiency in actual operation The building load is the range of almost 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate performance air conditioner corresponding not only to the rated performance at 100% load, but also to low to medium load
Load curve (a typical office building)
Building load (%)
100
80
Large propeller fan
DC inverter control
60
High performance and low noise realized by large propeller and optimization of angle.
Efficiency is improved by mounting of new active filter module.
40 20 0
0
3
6
9
12
15
18
21
24 Time (h)
DC fan motor Miniaturized, low noise, high efficiency, multi-stage DC fan motor is mounted.
Subcool heat exchanger
Pressure
Cooling performance is improved by mounting of dual tube heat exchanger.
High EER / COP
4.29 3.72
3.60
Large heat exchanger
High part load performance (6HP class)
4.20
Heat exchange performance is substantially improved by mounting of 3-row large heat exchanger.
3.95 3.45
66 % UP
50%
5.73
46 % UP
: COP
6 HP
100% 3.45
EER Cooling part load
04
Enthalpy
100% 3.95
Optimized refrigerant flow design Highly accurate parts
DC twin rotary compressor Efficiency in all load regions is good. Especially good performance from low to medium at normal operation. High Compressor efficiency
: EER
5 HP
Cooling performance improved
50%
5.75 High efficiency compressor motor
4 HP
effect
COP Heating part load
Conditions : Connected indoor units: AUXA30GALH+AUXD24GALH Cooling : indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWB Heating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB
DC Twin Rotary compressor
Compressor capacity
High
05
FEATURES
More Comfort
Operation Performance is Efficiently Controlled.
Powerful Heating
Room temperature set point limitation
Economy operation
The minimum and maximum temperature range can be set.
The temperature setting is offset automatically over a certain period of time.
Heating capacity is improved at low outdoor temperature by our advanced technology.
Heating
(°C)
Cooling
30
Heating capacity (kW)
Various Energy Saving Function
16.6
Set Temp. Down
Heating Set Temperature
MAX. - 4°C
28
Down
Down
33%
Down
Economy operation Control Temperature
26
J-II series (6HP)
Current model (6HP class)
UP !
Economy operation
24 Set Temp.
22
Economy operation
Economy operation Control Temperature
20 18
MAX. +2°C Cooling Set Temperature
16
Up
-20
Up
-10
0
7 Outdoor temperature (°C)
14 12 10 Original Set Temp.
Set point limitation setting
Capacity save operation
Low Noise Design
The power consumption at peak can be limited.
Setting range
100%
Low noise design of outdoor unit
Capacity
Capacity save
Low noise mode
Significantly reduced noise by optimized airflow structure design of outdoor unit.
Setting level
Outdoor unit can be switched to silent mode, depending on the installation environment.
Current model
56dB J-II series
(4~ 6HP)
53dB
80% 60%
Noise level
Rated noise value
-5dB ~ -6dB
40% 0%
Low noise mode
Central Remote Controller
Time
6HP class (Cooling)
Time
Various Comfort Control Function
Wasteful Operation is Prevented. Auto Off function Able to prevent wastage of energy.
OFF OFF OFF
Easy auto changeover function
Non-stop oil recovery operation
Auto louver grill (Option for Slim Duct)
At the auto mode, cooling and heating mode is switched automatically to maintain the setting temperature.
The product continues to operate without stopping the cooling or heating operation during oil recovery modes.
Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet
Temp. (°C)
Cooling operation
Heating operation
With Auto Louver
18:00
20:00
22:00
Set Temp.
J-II series
35
ON
30 Operation stopped at oil recovery
Heating operation Function setting is required. 1 indoor unit (Master) can apply this function.
06
Current model
Time
ON
25 20
OFF
Temperature(°C)
40
15 Time
07
FEATURES
More Convenience Central Control of Small Office, Shop, etc. Building Management System
Individual and Central Control of Large Homes A/C central controller
Convertor for BMS Control
Central Remote Controller
Wireless Remote Controller
Wired Remote Controller
UTY-LNH*
UTY-RNK*
UTY-DCG*
Network Convertor for LONWORKS ® UTY-VLGX Network Convertor UTY-VGGXZ1
BACnet ® Gateway (Software)
Group Remote Controller UTY-CGG*
UTY-ABGX
Max. controllable 18 indoor units
Lighting facilities Ventilation system
Central Remote Controller
Security system
UTY-DCG* Max. controllable 100 indoor units
• Automatic display of number of connected indoor unit • Max. controllable 100 units
or Touch Panel Controller
Group Remote Controller UTY-CGG*
UTY-DTG*
Wired Remote Controller (Touch Panel)
Max. controllable 400 indoor units
Simple Remote Controller
System Controller (Software) UTY-APGX Max. controllable 1,600 indoor units
• Max. controllable 18 indoor units
UTY-RSK*
UTY-RHK*
With operation mode
Without operation mode
UTY-RNR*
R*: RY (FUJITSU), RG (GENERAL) K*: KY (FUJITSU), KG (GENERAL) H*: HY (FUJITSU), HG (GENERAL) G*: GY (FUJITSU), GG (GENERAL)
G*: GY (FUJITSU), GG (GENERAL)
Control system composition example
Control system composition example
VRF network system
Building control computer Central Remote Controller
or
Network Convertor for LONWORKS ®
Central Remote Controller or
System Controller (Software) BACnet ® Gateway (Software)
08
Touch Panel Controller
Network Convertor
Wired Remote Controller
Group Remote Controller
Group Remote Controller
Wired Remote Controller + Simple Remote Controller
Simple Remote Controller
IR Receiver Unit + Wireless Remote Controller
Wireless Remote Controller
Wired Remote Controller + Wireless Remote Controller
09
FEATURES
More Design Flexibility
Easy Installation
Long Piping Length
Easier Installation
Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design.
Easy piping connection
Flexible installation of outdoor unit
Improvement of the reliability by decreasing the flare connection.
Corresponds to the outdoor unit concentration installation.
J-II series Actual piping length
Height difference between outdoor
120 m max.
and indoor units
Flare connection
Previous model EV kit
30 m max. Terminal box Power supply cable
Piping length from first separation tube to the farthest indoor unit
15 m max. Total piping length
• Decreasing wiring mistakes by using non-polar 2 wires.(Remote controller cable is 3 wires)
180 m max.
• Improvement of wiring installation by common with V-II power supply method.
2 to 7 units
Indoor unit 2 to 8 units
6 HP
2 to 9 units
Flexible installation by 4 way pipe direction
Convenient Commissioning Support
Number of connectable indoor unit
5HP
Power supply (Indoor )
Easy wiring connection
High Capacity Connection 4 HP
Reduced installation intervals by front access
Power supply (Outdoor )
Height difference between indoor and indoor units
40 m max.
Flare connection
12 types, 48 models
Connectable indoor unit capacity range
Automatic address setting function
Connection check function
The address of each indoor unit can be automatically set by button switch of outdoor unit.
Possible to confirm whether wiring connection and address setting are correct by check run function for a short time.
130 % max. 3
7
1
0
2
4
5
6
• Display connected indoor unit numbers • Duplicately set address number of indoor unit can be displayed
Press the push button of outdoor unit.
Wide operating range Installation in extreme temperature conditions is possible due to an increase in operational range. Cooling : -5°C~46°C Heating : -20°C~21°C
(°C) 50 40
Heating 21°C
30 20 10
-10
Easy to connect with V-II communication system
-20°C area Operation possible in heating.
0
-20
10
Cooling 46°C
-5°C -20°C
J-II system
V-II system
Connects without a converter
It is possible to connect directly with the transmission cable of the V-II system without convertor.
11
FEATURES
OUTDOOR UNITS
Specifications
Easy Maintenance
AJ*A40LALH
Model name Capacity range
HP
Max.connectable indoor unit*1
AJ*A45LALH
4
5
6
7
8
9
Power source
1Ø, ~ 230 V, 50 Hz
Easy to read 7-segment LED Confirm detail operational and trouble status without using specific equipment
Input power
Error status can be checked easily via the indoor unit wired controller An error code is displayed on a liquid crystal screen.
12.1
14.0
Heating
13.6
16.0
18.0
Cooling
3.25
3.89
4.49 4.56
Cooling
Capacity
Design for Easy Maintenance
kW
kW
Faulty unit number (Remote controller address)
3.17
3.81
EER
Cooling
3.72
3.60
3.45
COP
Heating
4.29
4.20
3.95
6,200
6,400
6,900
50
51
53
52
53
55
W/W m 3/h
Air flow rate Cooling
Sound pressure level
dB(A)
Heating Heat exchanger fin
Blue fin mm
Weight
kg
Refrigerant charge
kg
Error code
Liquid
Connection pipe diameter
1,334 x 970 x 370 117 4.8
5.3 9.52
mm
Gas
7-segment LED
15.5
Heating
Dimensions (H×W×D)
Wired Remote Controller
AJ*A54LALH
15.88
Cooling
Operation temperature range
19.05 -5 to 46
°CDB
Heating
SU MO TU WE TH FR SA
-20 to 21
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. The protective function might work when using it outside the operation range.
Simple Remote Controller
Dimensions
Remote controller address
Error code
166
Movable PCB panel
650
154
AJ*A40LALH / AJ*A45LALH / AJ*A54LALH
32
Emergency Stop Function
(410) 40
51(Gas)
370
43(Liquid)
(Unit : mm)
Easier for maintenance work behind the PCB
36 970
370
12
Terminal blocks (Transmission) Central Remote Controller or Emergency stop function
Terminal blocks (Power)
Emergency stop function
Emergency stop function
3-Way valve (Liquid)
907
Touch T hP Panell Controller
1000
Note : In case of received Emergency alarm by Indoor / outdoor unit : All units connected within same refrigerant system will be stopped. Central Remote Controller or Touch Panel Controller : all units connected within VRF network system with Central Remote Controller or Touch Panel Controller will be stopped.
32
1334
Emergency alarm can be received by indoor, outdoor units, Central Remote Controller or Touch Panel Controller when they received it, all units will be stopped.
AJ* : AJY (FUJITSU), AJH (GENERAL)
21
Detail
21
65
Ø28 (Cable port) Ø28 (Cable port) Pipe port
A
14
15
50
Ø28 (Cable port) Ø28 (Cable port) Pipe port
55
A 65
142
155
120 50
131 87
25 95 Pipe port
50
Equipment Detail (Diagram)
USB adaptor (Field supplied)
89
Software 227
Service Tool UTY-ASGX
• Last 5 min. operation memory can be also recorded.
341 305
• Detail operation status and recent error history can be checked and analyzed by using Service Tool.
Ø28 (Cab
le port)
Connection to Service Tool
50
Transmission cable (Non-polar 2 wires)
21
Trouble diagnosis by Service Tool
279 ((Liquid valve)) 297 (Gas valve)
le port)
ab Ø28 (C
70
111
3-Way valve (Gas)
50
438
Pipe & cable port 622
12
AJ* : AJY (FUJITSU), AJH (GENERAL)
13
INDOOR UNITS
Indoor Unit Lineup
Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs.
12 Types, 48 Models, Capacity range from 2.2kW to 14.0kW Capacity range (kW) Model code
2.2
2.8
3.6
4.5
5.6
7.1
9.0
11.2
12.5
14.0
7
9
12
14
18
24
30
36
45
54
AUXB07GALH
AUXB09GALH
AUXB12GALH
AUXB14GALH
AUXB18GALH
AUXB24GALH
AUXD18GALH
AUXD24GALH
AUXA30GALH
AUXA36GALH
AUXA45GALH
AUXA54GALH
ARXA30GBLH
ARXA36GBLH
ARXA45GBLH
ARXC36GATH
ARXC45GATH
AB*A36GATH
AB*A45GATH
Compact Cassette Cassette Cassette
Low Static Pressure Duct ARXB07GALH
ARXB09GALH
ARXB12GALH
ARXB14GALH
ARXB18GALH
ARXD07GALH
ARXD09GALH
ARXD12GALH
ARXD14GALH
ARXD18GALH
Slim Duct (Drain pump internal)
Duct
ARXD24GALH
Medium Static Pressure Duct ARXA24GBLH
High Static Pressure Duct
Floor (*Same as Ceiling models)
Floor
AB*A12GATH
AB*A14GATH
AB*A18GATH
AB*A24GATH
Concealed Floor (*Same as Low Static Pressure Duct models) ARXB07GALH
ARXB09GALH
ARXB12GALH
ARXB14GALH
ARXB18GALH
ARXD07GALH
ARXD09GALH
ARXD12GALH
ARXD14GALH
ARXD18GALH
ARXD24GALH
AB*A12GATH
AB*A14GATH
AB*A18GATH
AB*A24GATH
AB*A30GATH
AS*A12GACH
AS*A14GACH
AS*A18GACH
AS*A24GACH
AS*A30GACH
Slim Concealed Floor (*Same as Slim Duct models)
Ceiling
Ceiling AB*A54GATH
Wall Mounted AS*A07GACH
Wall Mounted
AS*A09GACH
With this model,
Wall Mounted (EEV external)
connection of
AS*E07GACH
AS*E09GACH
AS*E12GACH
AS*E14GACH
EV kit is necessary.
AB* : ABY(FUJITSU), ABH(GENERAL) AS* : ASY(FUJITSU), ASH(GENERAL)
14
15
INDOOR UNITS
Compact Cassette AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH
Ceiling panel
A B C D
2
Quiet quality
High efficiency design by 2 stage structure
Optimization of wing form (laminar wing type) and wing number (7 blades each)
An evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.
Adoption of laminar wing Quiet
2
Long life filter : standard equipment
3
Adaptation of transparent drainage parts
570mm
Optional parts
570mm
Spin direction
No airflow separation
Airflow direction
Specifications
Dimensions AUXB07GALH
AUXB09GALH
AUXB12GALH
AUXB18GALH
AUXB24GALH
2.2
2.8
3.6
4.5
5.6
7.1
2.8
3.2
25
25
4.1
5.0
6.3
8.0
29
35
36
540
550
84
600
680
710
1,030
Power source
(Unit : mm)
Models: AUXB07 / AUXB09 / AUXB12 / AUXB14 / AUXB18 / AUXB24
530
590
580
830
390
390
400
450
High
34
35
37
38
41
50
30
30
34
34
35
44
25
25
27
27
27
30
dB(A)
Low mm kg Liquid (Flare) mm
Drain
ø15.88
146 285
285
183
40
UTG-UF*C-W mm
50 x 700 x 700
kg
2.6
F* : FY (FUJITSU) ; FG(GENERAL) Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Ceiling
Gas pipe Control Box Liquid pipe
262
Weight
ø12.70 ø25 (I.D) ; ø32 (O.D.)
Model name Dimensions (H x W x D)
17 ø9.52
30
Gas (Flare)
15 ø6.35
123
Connection pipe diameter
Drain hose
19
Weight
IR receiver
245 x 570 x 570
215
Dimensions (H x W x D)
114
Med
370
450 350
□ 570 : Indoor unit
450 350
114
Sound pressure level
m3/h
Low
Med
530
High
530 Hanging bolt position
700
700
kW W
Airflow rate
16
AUXB14GALH
Air Outlet Shutter Plate : UTR-YDZB Insulation Kit for High Humidity : UTZ-KXGC Fresh Air Intake Kit : UTZ-VXAA
230V ~, 50Hz
Input power
Cassette Grille
Worlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size)
□ 580 to 660 Ceiling openings
Quiet
In the case of a previous fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven.
Heating
3.0 3.0 3.0 3.0
B : 2-stage turbo fan D : Panel
Compact design
Previous turbo fan
Cooling
2.7 2.7 2.7 2.7 2.7 2.7
Airflow runs through smoothly along the laminar wing Slow
Capacity
High ceiling mode
07 09 12 14 18 24
During installation, maintenance and operation, the drain pump and kit can be checked easily.
Laminar wing
20%UP
Model name
Standard mode
540 Hanging bolt position
=
Model code
30
+
Heat exchange efficiency
The maximum height from floor to ceiling (m)
Maintenance of fan motor and fan
A : Fan motor C : Bell-mouth
Designed by CFD-analysis (fluid) simulations
Wind velocity Fast
The compact cassette can be installed up to a height of 3.0m (12/14/18/24).
Grille cover
Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily.
2-stage turbo fan
2-stage turbo fan
3
High ceiling mode
1
1-stage
Max.
700mm
1
Compact size panel design that fits standard ceiling panel (600x600mm)
2-stage
High lift drain pump
Improvement of the airflow distribution
Models
17
INDOOR UNITS
Cassette Improvement of the airflow distribution
Models
AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH
High lift drain pump
The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution. Front part
Ceiling panel
Ceiling
Bottom view
Rear part
Powerful, wide airflow and quiet operation
Max.
850mm
High ceiling mode
Much less temperature irregularity happens by spreading airflow widely
Round louvre
This cassette can be installed up to a height of 4.2m (36/45/54). The maximum height from floor to ceiling (m) Model code
Adjustment of hanger position is possible after installation
High efficiency turbo fan with 3-dimensional blade
High ceiling mode
3.0 3.0 3.2 3.2 3.2 3.2
3.5 3.5 3.6 4.2 4.2 4.2
18 24 30 36 45 54
Detachable Grille corner
High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.
Standard mode
Previous turbo fan Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling.
Adjustment can be done just taking off the corner part
500mm 450mm
3-dimensional blade
Previous blade
Optional parts
One way aperture installation Heat exchanger < Motor side >
Heat exchanger < Motor side >
Separation phenomenon of airflow causes noise
Quiet
Wind velocity Fast
No airflow separation
Parallel apertures
Uneven airflow
Slow
: Turbulent flow noise
Dimensions AUXA36GALH
AUXA45GALH
AUXA54GALH
230V ~, 50Hz 5.6
7.1
9.0
11.2
12.5
14.0
6.3
8.0
10.0
12.5
14.0
16.0
39
46
59
80
99
119
1,150
1,280
1,600
1,800
1,900
2,000
940
1,040
1,300
1,300
1,370
1,370
Low
870
870
1,100
1,100
1,100
1,100
High
36
38
40
44
46
47
30
33
38
38
39
39
29
29
33
33
33
33
W High
Med
dB(A)
Low Dimensions (H x W x D) Weight Connection pipe diameter
mm
246 x 840 x 840
kg
22
27
mm
Weight
ø15.88
ø19.05
358
(Control) Box
ø25 (I.D.) ; ø32 (O.D.)
Drain Model name Dimensions (H x W x D)
Drain hose
ø9.52
Liquid (Flare) Gas (Flare)
288 x 840 x 840
358
278
mm
50 x 950 x 950
kg
5.5
G* : GY(FUJITSU) ; GG(GENERAL) Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
60 40
UTG-UG*A-W
298(256)
Sound pressure level
m3/h
200
Med
796 Hanging bolt position
950
Ceiling
10
Airflow rate
IR receiver (Option)
142
Input power
kW
142
Heating
Liquid pipe
Gas pipe
44 140
Cooling
Capacity
Models: AUXD18 / AUXD24 (Slim type) AUXA30 / AUXA36 / AUXA45 / AUXA54
420 699 Hanging bolt position □ 860 to 910 Ceiling opening
AUXA30GALH
□ 840 : Indoor unit
AUXD24GALH
Power source
607
AUXD18GALH
Model name
(Unit : mm) ( ) : AUXD18 / AUXD24
950
: Airflow direction
Specifications
18
UTY-LRH*B1 UTR-YDZC UTG-BGYA-W UTZ-KXGA / UTZ-KXGB UTG-AGYA-W UTZ-VXGA
H*: HY(FUJITSU), HG(GENERAL) : Spin direction
Cassette Grille
IR Receiver Unit : Air Outlet Shutter Plate : Panel Spacer : Insulation Kit for High Humidity : Wide Panel : Fresh Air Intake Kit :
Wire hole
19
INDOOR UNITS
Low Static Pressure Duct / Concealed Floor Models
ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH
Compact design
Flexible installation
Ultra-slim duct air conditioner for easy installation
Ceiling concealed Max.
850mm
Height
217mm ARXB07GALH ARXB09GALH
ARXB12GALH ARXB14GALH ARXB18GALH
Slim size (217mm) allows installation even where the space behind the ceiling is narrow. Floor concealed
Small and compact indoor unit suitable for many applications
Two-direction drain piping
Concealed Floor
Filter (Accessory) ARXB07 / ARXB09
Duct indoor unit
Low noise level
Filter (2pcs.)
Two-direction drain piping
Low static pressure mode
7
Model Static pressure range
Pa
Noise level (Low speed)
dB(A)
9
12
14
Airflow drop prevention
Air-intake Air intake direction can be selected to match the installation site.
Low noise realized
18
Optional parts
0 to 50 24
27
25
30
Filter (3pcs.)
Normal mode
Airflow
A low noise level has been achieved for each capacity
ARXB12 / ARXB14 / ARXB18
30
Bottom side
Remote Sensor Unit : UTY-XSZX IR Receiver Unit : UTB-YWC Drain Pump Unit : UTZ-PX1BBA
Back side
Static pressure (Pa)
Specifications
Dimensions ARXB07GALH
ARXB09GALH
ARXB12GALH
Power source
High Med
dB(A)
Low Dimensions (H x W x D) Weight Connection pipe diameter
96
886 (596)
370
440
590
800
890
(Bolt pitch)
310
370
500
750
810
280
340
450
700
730
0 to 50
0 to 50
0 to 50
0 to 50
0 to 50
25
25
25
25
25
29
31
30
33
36
26
29
28
32
34
24
27
25
30
30
kg
15
mm
Note : Specifications are based on the following conditions.
ø6.35
ø9.52 ø15.88
Brackets
2
47
850 (560)
85
150
Airflow outlet
953 (663) 94 (50)
ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Brackets
3
23
ø12.70
217 194
Control box
1
24
217 x 953 x 595 22
170
90
217 x 663 x 595
Drain
20
63
mm
Liquid (Flare) Gas (Flare)
55
364
Sound pressure level
6.3
46
65 75
Pa Standard static pressure
5.6
5.0
587
Static pressure range
4.5
4.0
390
m3 / h
Low
3.6
3.2
(Bolt pitch)
Med
2.8
2.8
595
High
2.2
166
W
Input power
886 (596)
*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.
20
kW
Models: ARXB07 / ARXB09 / ARXB12 / ARXB14 / ARXB18
Control box
600 (400)
10
Cooling Heating
Airflow rate
ARXB18GALH
150
Capacity
ARXB14GALH
230V ~, 50Hz
217
Model name
(Unit : mm) ( ) : AR7 / AR9
1 Refrigerant piping flare connection (Gas) 2 Refrigerant piping flare connection (Liquid) 3 Drain piping connection
21
INDOOR UNITS
Slim Duct / Slim Concealed Floor Auto Louver Grille Kit (Option)
High lift drain pump
Models (Drain pump internal model)
ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH
Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Max.
Max.
850mm ARXD07GALH ARXD09GALH
ARXD12GALH ARXD14GALH
Slim Duct
850mm
Auto Louver Grille
ARXD18GALH
Drain hose is standard accessory
Selectable with a wide range of static pressure
Slim design and wide range of static pressure for flexible installation. ARXD24GALH
Slim Concealed Floor
By using DC fan motor, it is possible to change of static pressure range 0 to 90Pa. The change of static pressure range is possible by remote controller.
Wired Remote Controller
Static pressure range
Wireles Remote Controller
Filter (Accessory)
0 to 90 Pa
ARXD07 / 09 / 12 / 14 / 18
*24 model is 0 to 50Pa
Filter (2pcs.)
ARXD24
Filter (3pcs.)
Flexible installation Ceiling concealed
Slim design
Air-intake
This model is slim design, it can install at the place where a ceiling is narrow.
Air intake direction can be selected to match the installation site.
Optional parts
Floor concealed
Drain port
Remote Sensor Unit : UTY-XSZX IR Receiver Unit : UTB-YWC Auto Louver Grille Kit : UTD-GXSA-W (for ARXD07/09/12/14GALH) UTD-GXSB-W (for ARXD18GALH) UTD-GXSC-W (for ARXD24GALH)
Height
198mm Bottom side
Back side
Specifications
Dimensions
High Med
m3/ h
Low Static pressure range
2.8
3.6
4.5
5.6
2.8
3.2
4.0
5.0
6.3
8.0
44
50
54
92
83
122
550
600
600
800
940
1,330
490
550
510
710
840
1,240
440
480
450
610
750
1,100
0 to 90
0 to 90
0 to 90
0 to 90
0 to 90
0 to 50
25
25
25
25
25
25
28
29
30
34
34
35
25
26
27
32
32
32
7.1
dB(A)
Low
kg
Weight Connection pipe diameter
22
Liquid (Flare) Gas (Flare)
28
198 x 700 x 620 17
18 ø6.35
mm
Drain Note : Specifications are based on the following conditions.
22
24
24
mm
Dimensions (H x W x D)
28
29
198 x 900 x 620
198 x 1,100 x 620
22
26
30
48
F (All surroundings)
E D C (Bolt pitch) 43
78
Med
168
High
198
Sound pressure level
G
82
Pa Standard static pressure
51
10
ø9.52
ø12.70
ø15.88 ø25 (I.D.) ; ø32 (O.D.)
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
174
W
Input power
2.2
B A
31
ARXD07-14
ARXD18
A
700
900
1100
B
650
850
1050
C
734
934
1134
D
650
850
1050
E
P100x6=600
P100x8=800
P100x10=1000
F
18xØ5
22xØ5
26xØ5
G
574
774
974
47
kW
78 55
Heating
Airflow rate
*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.
230V ~, 50Hz Cooling
Models: ARXD07 / ARXD09 / ARXD12 / ARXD14 / ARXD18 / ARXD24
89
Capacity
ARXD24GALH
ARXD18GALH
152 71
Power source
ARXD14GALH
30
ARXD12GALH
377
ARXD09GALH
(Bolt pitch)
ARXD07GALH
Model name
(Unit : mm)
119
Drain pump
163
Drain pump built-in
69 144 264 367 620
ARXD24
23
INDOOR UNITS
Medium Static Pressure Duct Selectable with a wide range of static pressure
Models
ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH
It is possible to change of static pressure range 0 to 150Pa.
Easy maintenance See below for the case of rear suction type
Static pressure range
New model 1
0 to 150 Pa
1.Control box 2.Fan casing
4
3.Fan
Can be installed for various location
Low energy consumption by DC fan motor. Selectable with a wide range of static pressure.
It can be installed in such locations as high-rise condominiums by low static pressure design.
4.Motor
3
2
It can also be installed in wide spade when high static pressure is required, such as for offices.
Bottom panel: 2 pieces
The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.
Slim & Compact design In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270mm, Further space savings have been achieved by mounting the electrical control box internally inside the chassis. 1,200
Low energy consumption by high efficiency DC fan motor
NEW
Embedded in Ceiling
The change of static pressure range is possible by remote controller
Improved motor efficiency from previous model.
1,135mm
Installation styles
Easy setting by using remote controller
NEW
Two-direction drain piping
Control box is now included as part of the main chassis 270mm
Optional parts One touch operating and easy to install long life filter (Optional Parts)
24 model
Dimensions
Model name
ARXA24GBLH
ARXA30GBLH
7.1
ARXA36GBLH
ARXA45GBLH
9.0
11.2
12.5
8.0
10.0
12.5
14.0
94
108
194
240
1,280
1,410
1,840
1,970
990
1,280
1,600
1,860
840
1,150
1,470
1,640
Power source
230V ~, 50Hz Cooling
Remote Sensor Unit : UTY-XSZX Long Life Filter : UTD-LF25NA Flange (Square) : UTD-SF045T
Duct indoor unit Two-direction drain piping
30 / 36 / 45 model
Specifications
Capacity
Hanging from Ceiling
Flange (Round) : UTD-RF204 IR Receiver Unit : UTB-YWC Drain Pump Unit : UTZ-PX1NBA
(Unit : mm)
Models: ARXA24 / ARXA30 / ARXA36 / ARXA45 *Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.
kW
Static pressure range Pa Standard static pressure Sound pressure level
High Med
dB(A)
Low
kg
Weight
0 to 150
0 to 150
50
50
60
31
34
37
41
27
32
35
38
23
29
33
36
36
Gas (Flare)
264
264 82
ø205 hole
Note : Specifications are based on the following conditions.
ø15.88
75
168
1
3
2
P.C.D. ø225
40
121
ø9.52 mm
3
240 281
264
Front view
270 x 1,135 x 700
Liquid (Flare)
Drain
24
0 to 150
40
mm
Dimensions (H x W x D)
Connection pipe diameter
0 to 150
138
ø200 (knock out hole)
700
m 3/h
Low
447(Bolt pitch)
Med
114 66 32
1177(Bolt pitch) Outlet
270 32
173
High
161
Airflow rate
240
W
Input power
138
Heating
1015 1135
107
240 270
Top view
ø19.05
Side view (R)
Side view (L)
ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
1 Refrigerant piping flare connection (Liquid) : 2 Refrigerant piping flare connection (Gas) : 3 Drain piping connection (Drain pipe)
Rear view
25
INDOOR UNITS
High Static Pressure Duct Models
Low noise
ARXC36GATH ARXC45GATH
Models : ARXC36 / ARXC45
Design also corresponding to high static pressure
Cutting off the corners of the conventional indoor unit front panel and fan casing, has enabled less turbulent air flow. Low noise is realized by adopting a plastic case and a plastic fan.
These indoor units allow for high airflow quantities
ARXC36GATH ARXC45GATH
Previous model
Max.
250Pa
New model (ARXC36GATH)
ARXC36GATH : Plastic fan [45dB(A)] * Model : Material (At 100Pa : Actual noise measurement value)
500mm
Easy installation (Compact size & Lightweight) Models : ARXC36
1,050
Volume
47.5% down
Heat exchanger
Weight
42% down
400mm
A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight.
500
Plastic fan ø225mm
400
ARXC36GATH : 43kg (unit: mm)
Specifications ARXC36GATH
Power source
High Med
m3/ h
Low Static pressure range Pa Standard static pressure High Med
dB(A)
14.0
405
715
2,600
3,500
1,950
3,000
1,450
2,460
100 to 200
100 to 250
100
100
45
49
38
45
mm kg
Weight
Gas
400 324
108
88
Rear view
1 2 3
71 4 295
42
Side view (L)
400 x 1,050 x 500 43
14
371 356 208
1,080(Bolt pitch) 1,000 862
851 1,050 Top view
Side view (R)
85
46 ø9.52 (Flare)
Liquid mm
Drain Note : Specifications are based on the following conditions.
26
12.5
12.5
32
Low Dimensions (H x W x D)
Connection pipe diameter
11.2
41 123 139
kW W
Input power
Sound pressure level
Models: ARXC36 / ARXC45
230V ~, 50Hz Cooling Heating
Airflow rate
(Unit : mm)
585 500(Bolt pitch)
Capacity
ARXC45GATH
Long-Life Filter : UTD-LF60KA IR Receiver Unit : UTB-YWC Remote Sensor Unit : UTY-XSZX
Casing (Plastic)
Dimensions
Model name
Optional parts
ø19.05 (Flare) ø25 (I.D.) ; ø32 (O.D.) Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection
Front view
27
INDOOR UNITS
Floor / Ceiling Models
AB*A12GATH AB*A14GATH AB*A18GATH AB*A24GATH
Double auto swing
Super vane
A combination of up/down and right/left directional swing allows three-dimensional air direction control.
Double Louvre Super vane with newly developed special configuration boosts airflow sending cool air quickly to every corner of the room.
RIGHT and LEFT SWING
The slim and lightweight design allow the unit to be suspended from the ceiling or installed on the floor. This type suits many room designs
2
UP and DOWN SWING
3
1
4
1
5
Auto-closing louvre
2
Floor standing
3
When operation is stopped, the louvres will automatically close. (This function is available on all non-ducted models.)
4
5 steps selectable
4 steps selectable
Compact design Symmetrical, slim and compact design.
High power DC fan motor
Flexible installation Example for floor installation
Example for ceiling installation
Floor console
Under ceiling
• High power • Wide rotation range • High efficiency
655
990
Specifications
Dimensions
Model name
AB*A12GATH
AB*A14GATH
AB*A18GATH
AB*A24GATH
3.6
4.5
5.6
7.1
4.0
5.0
6.3
8.0
30
42
74
99
660
780
1,000
1,000
Power source Capacity
kW W
Input power High Med
Sound pressure level
m3/ h
570
640
720
820
Low
490
550
580
680
High
36
40
46
47
32
36
39
42
28
34
35
37
Med
dB(A)
Low mm
Dimensions (H x W x D)
kg
Weight Connection pipe diameter
(Unit : mm)
(Unit : mm)
Models: AB*A12 / AB*A14 / AB*A18 / AB*A24
230V ~, 50Hz Cooling Heating
Airflow rate
199
Liquid (Flare) Gas (Flare)
mm
199 x 990 x 655 25
26
27
26
ø6.35
ø9.52
ø12.70
ø15.88
Drain
2
1
ø25 (I.D.) ; ø32 (O.D.)
2 1
AB*: ABY(FUJITSU), ABH(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain piping connection
3
28
3
29
INDOOR UNITS
Ceiling Models
AB*A30GATH AB*A36GATH AB*A45GATH AB*A54GATH
Double auto swing and wide airflow
High lift drain pump
Auto airflow direction and auto swing
Optional drain pump unit allows flexible installation design.
Right and left
Easily concealed in any installation
Max.
500mm
Fresh air intake 5 steps selectable Up and down Fresh air 1 Indoor
2
Outdoor
3 4
High power DC fan motor
4 steps selectable
Installation
• High power • Wide rotation range • High efficiency
Long airflow Open
Concealed
Long Airflow ensures comfort to every corner of a large room.
Wall mounted (Field Supplied)
Long-life filter
-flow
e air
tanc
dis ong
High Efficiency long-life filter doubles the life of the filter compared to standard filters.
L
General installation pattern which suspends the indoor unit from the ceiling.
Installation pattern where part of the indoor unit is embedded into the ceiling.
Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient.
Specifications
Dimensions AB*A30GATH
Model name
AB*A36GATH
Power source Capacity
Cooling kW W
Input power High Med
Sound pressure level
AB*A54GATH
m3/ h
9.0
11.2
12.5
14.0
10.0
12.5
14.0
16.0
66
85
131
180
1,630
1,690
2,010
2,270
1,370
1,400
1,600
1,780
Low
1,140
1,170
1,230
1,280
High
42
45
48
51
38
38
42
45
33
34
35
36
Med
dB(A)
Low mm
Dimensions (H x W x D)
kg
Weight Connection pipe diameter
AB*A45GATH
Optional parts Hight
Drain Pump Unit : UTR-DPB24T Flange : UTD-RF204
240mm
(Unit : mm)
Models: AB*A30 / AB*A36 / AB*A45 / AB*A54
230V ~, 50Hz
Heating
Airflow rate
Slim & Compact design
Liquid (Flare) Gas (Flare)
mm
240 x 1,660 x 700 46
48
ø9.52
ø9.52 ø19.05
ø15.88
Drain AB*: ABY(FUJITSU), ABH(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
ø25 (I.D.) ; ø32 (O.D.)
1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3
3 Drain piping connection 2
30
1
3
31
INDOOR UNITS
Wall Mounted Models (EEV internal model)
Models (EEV external model)
AS*A07GACH AS*A09GACH AS*A12GACH AS*A14GACH
AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH
Compact size
Width
790mm
Powerful output even compact design
Though the indoor unit is compact, it features a large, high pressure cross fan (90mm diameter) in a centre mounted configuration and a Lambda type heat exchanger to provide plenty of power.
Auto swing louvre The Auto Swing Louvre function ensures that the air direction corresponds to the mode selected.
1
Compact and Stylish design indoor
2
ing Sw
3 4 Step Swing
790mm
Filter features Deodorizing effect
High quality air conditioning by incorporation of high performance filter.
(Odor reduction rate) Trimethylamine
Ammonia
Long-life* Ion Deodorization Filter
(ppm)
(ppm)
160
160 With no filter
120
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
New filter
80
80
New filter
40
40
Easy maintenance
• High power • Wide rotation range • High efficiency • Compact size
Easy maintenance has been realized as the front panel can removed for easy access. Open panel
0
0
(*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.)
With no filter
120
New style high power DC fan motor
30
0
60
120 (min)
0
30
60
120 (min)
Hydrogen sulfate (ppm)
Apple-catechin Filter
160 With no filter
120
New filter
80
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
Testing organization : Environmental Sanitary Inspection Center Test method : Deodorization Test
40 0 0
30
60
120 (min)
Specifications AS*A07GACH AS*A09GACH AS*A12GACH AS*A14GACH AS*E07GACH AS*E09GACH AS*E12GACH AS*E14GACH
Power source
230V ~, 50Hz
Sound pressure level
High Med
dB(A)
Low Dimensions (H x W x D) Weight Connection pipe diameter
3.6
4.5
2.8
3.2
4.1
5.0
2.8
3.2
4.1
5.0
17
18
22
34
15
16
21
34
490
500
560
670
490
500
560
680
450
450
480
490
450
450
480
490
370/420*1
370/420*1
420
420
370/420*1
370/420*1
420
420
35
36
39
44
34
35
38
43
33
33
35
37
32
32
34
35
27/31*1
27/31*1
31
32
26/30*1
26/30*1
30
30
790
mm
275 x 790 x 215
275 x 790 x 215
kg
9
9
Liquid (Flare) Gas (Flare)
mm
Drain EV Kit (option) AS*: ASY(FUJITSU), ASH(GENERAL) Note : Specifications are based on the following conditions.
32
ø6.35
ø6.35
ø12.70
ø12.70
ø13.8(I.D.) ; ø15.8-ø16.7(O.D.) -
215
470
3
530 660 1
EV kit (UTR-EV09XB/ UTR-EV14XB ) Optional parts:
2
ø13.8(I.D.) ; ø15.8-ø16.7(O.D.) UTR-EV09XB
416 222
UTR-EV14XB
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. *1 : This value is under cooling operation.
1 Refrigerant pipe flare connection (Liquid) 2 Refrigerant pipe flare connection (Gas) 3 Drain piping connection
OUTDOOR UNIT SIDE
32 UPWARD
19
wire
Install the unit as confiremed direction . Install the unit where it will not be tilted by more than 5°
Horizontal installation INDOOR UNIT SIDE
65 97 121
Low
2.8
65
m 3/h
2.2
wire
Med
4.5
Vertical installation
High
3.6
UPWARD
W
Input power
2.8
Models: AS*A07 / AS*A09 / AS*A12 / AS*A14 AS*E07 / AS*E09 / AS*E12 / AS*E14
Install the unit as confirmed direction. Install the unit where it will not be tilted by more than 5°
kW
230V ~, 50Hz
2.2
(Unit : mm)
275
Cooling Heating
Airflow rate
Symmetrical, clean design that suits all interiors.
Dimensions
Model name
Capacity
Symmetrical design
33
INDOOR UNITS
Wall Mounted “Vertical airflow” provides powerful floor level heating
Models
AS*A18GACH AS*A24GACH AS*A30GACH
Air conditioner filter features
5
(24/30)
Ion Deodorization Filter 2.5
Simple & Elegant Appearance Design
Organic coating fin used heat exchanger 0
3
6
9
12(m) (˚C)
46
o
Outside air conditions: 2 ˚C 60% Operation contents: Heating, Set temperature (Max set temp) 30 ˚C, 33 airflow Hi, Air direction downward and front
32
31
30
29
Apple-catechin Filter Pre Filter
Power diffuser (full open)
“Horizontal airflow” does not blow cool air directly at the occupants in the room 5
Antibacterial deodorizing pre-filter with special ceramic powder
Long-life* Ion Deodorization Filter
(24/30)
Compact & Slim design
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
2.5
By using DC fan motor, compact design is realized.
New model
0
Previous model
3
6
9
(*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.)
12(m) (˚C)
Power diffuser Outside air conditions: 35 ˚C 40% Operation contents: Cooling, Set temperature (Min set temp) 18 ˚C, airflow Hi, Air direction downward and front
Using different filters at both sides 15
16
17
18
Apple-catechin Filter
Easy maintenance
998mm
Simplification of drain pan cleaning improves maintenance-ability.
1120mm
DC fan motor
Specifications
Dimensions AS*A18GACH
Model name Power source Capacity
kW W
Input power High Med
m3/ h
Low High Sound pressure level
Med
dB(A)
Low
7.1
8.0
6.3
8.0
9.0
32
60
91
840
1,100
1,240
770
910
980
690
730
770
41
48
52
39
43
45
35
35
35
kg
Weight Liquid (Flare) Gas (Flare)
mm
AS*: ASY(FUJITSU), ASH(GENERAL) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
34
Models: AS*A18 / AS*A24 / AS*A30
320
520
320 x 998 x 228 15 ø9.52
Drain
(Unit : mm)
998
5.6
mm
Dimensions (H x W x D)
Connection pipe diameter
AS*A30GACH
230V ~, 50Hz Cooling Heating
Airflow rate
AS*A24GACH
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
590 228
721
ø15.88 ø12 (I.D.) ; ø16 (O.D.)
520
1 Refrigerant piping flare connection (Liquid) 2 Refrigerant piping flare connection (Gas) 3 Drain hose connection
35
CONTROLLER
Control System Every user's needs are supported by offering a variety of controls, such as individual control, central control and building management control options.
Building Management
Air Conditioning Individual Control
Air Conditioning Central Control System Controller
Software
UTY-APGX UTY-PEGX(Option)
USB Adaptor *2
System Outdoor unit
Wired Remote Controller (Touch panel) UTY-RNR*
Internet or Public Telephone Line
Indoor unit
(Field supplied) R*:RY(FUJITSU), RG(GENERAL)
Outdoor unit
Wired Remote Controller
Remote / Monitoring side
UTY-RNK*
Indoor unit
Touch Panel Controller
K*:KY(FUJITSU), KG(GENERAL)
UTY-DTG*
Simple Remote Controller UTY-RSK* G*:GY(FUJITSU), GG(GENERAL)
Central Remote Controller
K*:KY(FUJITSU), KG(GENERAL)
UTY-DCG*
General-purpose Building Control Computer
Signal Amplifier
UTY-RHK*
UTY-VSGXZ1
Without operation mode
G*:GY(FUJITSU), GG(GENERAL)
Group Remote Controller Connectable to various sized BMS/BAS *1
Simple Remote Controller
Network Convertor
K*:KY(FUJITSU), KG(GENERAL)
UTY-VGGXZ1
UTY-CGG*
Wireless Remote Controller
IR Receiver Unit
UTY-LNH*
UTB-YWC
G*:GY(FUJITSU), GG(GENERAL)
BACnet ® Gateway
Software
H*: HY(FUJITSU), HG(GENERAL)
UTY-ABGX
USB Adaptor *2
IR Receiver Unit UTY-LRH*B1
(Field supplied)
or
Card-key
Network Convertor (BMS / LONWORKS®)
External Switch Controller
*B:YB(FUJITSU), GB(GENERAL)
For single split
UTY-TEKX
UTY-VLGX
Network Convertor (Field supplied)
Web Monitoring Tool
Service Tool
Software
Internet or Public Telephone Line
The devices above cannot be connected to the S series. (Except System Controller & BACnet® Gateway)
36
(Monitoring side)
(VRF system side)
Software
SU MO TU WE TH FR SA
7
SU MO TU WE TH FR SA
7 3 6 9 12 15 18 21
3 6 9 12 15 18 21
UTY-ASGX
UTY-AMGX
*1. BMS/BAS: Building Management System / Building Automation System *2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation.
UTY-VGGXZ1
USB Adaptor *2
USB Adaptor *2
(Field supplied)
(Field supplied)
Transmission line (VRF Network)
LONWORKS ® Network
Remote controller line (2 wires)
Ethernet
Remote controller line (3 wires)
Signal line(Single split system)
USB cable
Group Remote Controller line
37
CONTROLLER
Wiring system
Max. transmission line length
• Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring. • Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers).
Comparison table of Controllers
3,600m Item
System Controller UTY-APGX Maximum 1,600 indoor units can be controlled. Air conditioning control Operation monitoring Status monitoring system Electricity charge calculation
USB Adaptor NW 1
Internet or Public Telephone Line
NW 2 NW 3 NW 4
Model name
(Remote / Monitoring side) Touch Panel Controller One Touch Panel Controller can control up to 400 groups / 400 indoor units.
Group Remote Controller Maximum 8 remote controller groups can be controlled
BACnet Gateway UTY-ABGX ®
IR Receiver Kit Cassette type indoor unit can be controlled with Wireless Remote Controller
USB Adaptor
Remote Controller line Maximum 16 units can be controlled
BACnet ®
Network Convertor for LONWORKS® UTY-VLGX
BACnet ® Operator Workstation (B-OWS)
System without Remote Controller Together with Touch Panel Controller, it is possible to build non remote controller system.
Web Monitoring Tool Trouble free operation at all times by remote monitoring system.
UTY-DTGG
1
8
100
400
1600
18
100
400
1600
Max. controllable groups
-
-
-
-
-
-
16
400
1600
-
-
-
-
-
-
-
-
Display
External Switch Controller Indoor units can be controlled by combining with Card-key switch such as hotel room.
Network Convertor UTY-VGGXZ1
-
Operation mode setting Fan speed setting Room temp. setting -
Room temp. set point limitation
Up/down air direction flap setting
Touch Panel Controller
Remote Controller line (2 wires) Central Remote Controller
Simple Remote Controller
IR Receiver unit
Remote Controller line (3 wires) USB cable
Indoor unit (Duct)
Group Simple Remote Controller Remote Controller
System Controller
Wireless Wired Remote Controller Remote Controller (Touch panel)
LONWORKS® Network Ethernet Signal line (single system) Group Remote Controller line
-
-
-
-
-
-
-
-
-
-
RC prohibition
-
-
-
-
-
-
-
Anti freeze setting
-
-
-
-
-
-
-
Setback cool/heat
-
-
-
-
-
-
Economy mode setting
-
-
-
-
-
Failure
-
-
-
-
-
Defrosting
-
-
-
-
-
Current time
-
-
-
-
-
Day of week
-
-
-
-
-
R.C. prohibition
-
-
-
-
-
Cooling/heating priority
-
-
-
-
-
Address display
-
-
-
-
-
Room temp
-
-
-
-
-
-
Multi language
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
On/Off, Temp,
-
-
-
-
-
-
-
-
-
Week
Week
-
-
-
Week
Week
Year
Year
8
4
-
-
-
4
20
20
144
-
-
-
-
-
-
-
-
On/off timer Sleep timer
-
-
-
-
-
-
-
-
-
Program timer
-
-
-
-
-
-
-
-
-
Auto off timer
-
-
-
-
-
-
-
-
Day off
-
-
-
-
-
10 30 ●
30
-
-
5
10
10
10
10
Status monitoring system
-
-
-
-
-
-
Electricity charge calculation
-
-
-
-
-
-
-
-
Emergency stop
-
-
-
-
-
-
Control via internet
-
-
-
-
-
-
-
-
E-mail notification for malfunction
-
-
-
-
-
-
-
-
-
-
-
-
Child lock
Password setting
Password setting
-
Error history
Control
Indoor unit (Cassette)
-
-
Min. unit of timer setting (Minutes)
Module link
-
-
mode, times per day
Timer
Wired External Switch Remote Controller Controller
-
-
Summer time
Transmission line
-
-
Single system
Service Tool Extensive monitoring and analysis functions for installation and maintenance.
-
Group setting
Right/left air direction flap setting
Schedule timer Big Multi system
-
Test operation
Backlight
Outdoor unit
UTY-APGX
16
USB Adaptor
38
UTY-DTGY
UTY-DCGG
1
Period
(Monitoring side)
UTY-DCGY
UTY-CGGG
16
(VRF network system side)
(Monitoring side)
UTY-CGGY
UTY-LNHG
1
Name registration
Service Tool UTY-ASGX
(Monitoring side)
UTY-LNHY
UTY-RHKG
16
IR Receiver Unit Duct type indoor unit can be controlled with Wireless Remote Controller.
Network Convertor UTY-VGGXZ1
Internet or Public Telephone Line
UTY-RHKY
UTY-RSKG
1
USB Adaptor
Web Monitoring Tool UTY-AMGX
UTY-RSKY
UTY-RNKG
16
Transmission line line is non-polar 2-conductor.
Signal Amplifier UTY-VSGX
UTY-RNKY
UTY-RNRG
Software
1
Card key
2 Remote Controllers Indoor unit can be controlled from both remote controllers.
UTY-RNRY
System Controller
16
LONWORKS®
LONWORKS® Network
Touch Panel Controller
Max. controllable indoor units
Air conditioning control function
BACnet
Simple Remote Simple Remote*1 Wireless Remote Group Remote Central Remote Controller Controller Controller Controller Controller
On / Off
Network Convertor UTY-VGGXZ1
®
Wired Remote Controller
Max. controllable remote controller groups
Central Remote Controller Maximum 100 indoor units can be controlled.
Building Management System
Wired Remote Controller (Touch panel)
Key lock
Child lock
*1 "Operation mode" setting is not available for this model. *2 This function is available only through external input. control.
*2
● : Supported
*2
— : Not supported yet
-
Password setting
○ : Supported soon 39
CONTROLLER
Wired Remote Controller (Touch Panel)
Max. transmission controllable Max. line length
16
indoor units
UTY-RNR*
Various convenient functions Setback-Cool / Setback-Heat (Future release) ・Cooling / Heating is automatically started when the room temperature reaches a setting temperature even if the indoor unit is off.
Easy operation by high-definition large STN-LCD touch panel screen
In summer
• Easy finger touch operation with LCD panel • Built-in weekly/Daily timer(ON/OFF,Temp.,Mode) • Backlight enables easy operation in a darkened room • Room temperature display • Control up to 16 indoor units • Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish)
In winter
Setting temp.
Room temp.
Setting temp.
Setback-Heat function operation Setback-Heat function set
Setback-Cool function operation
Automatically start
Automatically stop
Setback-Cool function set
Automatically start
Automatically stop
Displays setting status and Limitations • The remote controller settings can be easily checked
Functions High performance and compact size
Various energy saving control
• In addition to the individual control, various energy saving controls can be realized using one remote controller only.
Auto OFF Timer • The indoor unit automatically turns off after a set time has passed. • The time interval for which auto off works can be set.
Individual control
Ex) At interval time hour (17:00 to 24:00)to prevent forgetting to turn off
Thermo sensor
Room temp.
Weekly timer
Auto off timer
Child lock • Lock / unlock method: Push the ON/OFF button and the screen (4 seconds)
Set interval time hour (17:00 to 24:00) ON
Auto OFF
Summer Time display • This function can be set easily from Menu screen
Set off time (30 to 240 minutes) OFF 17:00
Accurate and comfortable control • Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller.
24:00
Name Registration • Indoor unit names can be registered in the remote controller screen. This makes it easy to identify the indoor unit you want to control in the room.
2 schedules Weekly Timer • 2 schedules such as for the summer and winter can be set. • 8 setting changeable per day of week (Setting items: On/Off, Temperature, Mode, Time) Ex)
Simplified installation Schedule 1 (Summer schedule) Setting temp.
26°C
ON
OFF
Uses non-polar 2-wire type • The faulty wiring can be prevented by using non-polar 2-wire.
Schedule 2 (Winter schedule) Setting temp.
OFF
25°C
24°C
OFF
ON
OFF
I.U.
I.U.
Y1Y2 Y3
non-polar 2-wire
23°C
OK 8:40
11:40
17:30
20:40
Time
8:40 10:00
15:30 17:30
20:40
Address → Y1
Backlight • Backlight enable easy operation in a darkened room. • For the lighting time of Backlight, 30 or 60 seconds can be set. • Backlight activates while the buttons are operated and goes off 30 or 60 seconds after the operation stops.
23°C
Settable time range 10 to 120 minutes
Settable time range 10 to 120 minutes
02
01
Time
11:40
13:40
Time
Error History Display • The errors that occur in the indoor unit or remote controller are saved as a history. • A maximum of 32 error incidents can be saved.
Set Temperature Upper and Lower Limit Setting • The set temperature range can be set for each operation mode. (Cooling / Heating / Auto) During Cooling 30°C
During Heating
Specifications
30°C
UTY-RNR*
Model name
25°C 25°C
DC 12V
Power Supply Dimensions (H x W x D) (mm)
18°C
Original temp. setting range
Lower limit setting
10°C
Original temp. setting range
Upper limit setting
120 x 120 x 20.4 220
Weight (g) DC12V is supplied by the indoor unit.
40
03
Easy Maintenance
25°C
13:40
04
Y2
05
22°C
11:40
Y1
The appropriate indoor unit performs the air blow and LED lamps blink.
Setting temp. Set temperature change Auto return
24°C
Room temperature display
Y2
Heating operation
Setting temp. Set temperature change Auto return
Room temperature sensor
OK
Auto Address Setting/Setting Position Notification • Reduce errors and install time compared with the current specification Rotary SW • When will be set remote controller groups, can also be set automatically new Wired remote controller address • After auto address setting of new wired remote controller groups, what number can also confirm addresses
Time
Set Temperature Auto Return • The setting temperature automatically returns to the previous setting temperature. • The time range in which the set temperature can be changed is 10 to 120 minutes. Cooling operation
Y1Y2 Y3
R* : RY(FUJITSU), RG(GENERAL)
41
CONTROLLER
Wired Remote Controller
Max. controllable
16
indoor units
UTY-RNK*
Simple Remote Controller
Max. controllable
16
indoor units
UTY-RSK* UTY-RHK* (Without Operation mode)
The room temperature can be controlled by detecting the temperature accurately from the built-in sensor
Compact remote controller provides access to basic functions
• Simple operation with Built-in Weekly / Daily Timer. • Control up to 16 indoor units. • Up to 2 wired remote controllers can be connected to a single indoor unit.
• Up to 16 indoor units can be controlled with one remote controller. • Suitable for hotels or offices as it is easily operated with no complex functions. UTY-RSK*
Functions
Functions
Powerful features and compact size
Built-in timers
This Wired Remote Controller incorporates four primary functions into a single unit.
Weekly timer : Possible to set ON/OFF time to operate twice each day of the week.
Individual control
Thermo sensor
UTY-RHK* Without Operation mode
Weekly timer
Easy-to-understand time bar display
Setup screen example Set to Wednesday: 8:00 to 20:00.
Setback timer
0
3
6
9
12
24°C 15
18
Screen after setup
21 Time
User-friendly operation
Backlight
• Provides access to basic operations, such as Start / Stop, Fan control, Operation mode switching, and Room temperature setting. • A large On / Off button is provided in the centre of the remote controller for easy operation. • Can be used jointly with other individual control unit. • Following an error display, diagnostics can be carried out on the controller.
• Backlight enables easy operation in a darkened room. • Backlight activates during all button operations, and lasts 10 seconds in Operation mode and 5 seconds in stop mode after a button is pressed.
Simple installation
Functions summary
Setback timer : Possible to set temperature for two times spans and for each day of the week.
Accurate and comfortable
Setup screen example Set from Sunday to Saturday: 12:00 to 15:00, 28°C.
Sensor part
Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. This new wired remote controller and the optional remote sensor allows flexibility in sensor location, suitable for all requirements.
Thermo sensor display Control part for changing the thermo sensor
0
3
6
9
28°C 15 18
12
Can be mounted on the European Mounting Box (Installation dimension: 60mm) or the JIS Built-in Box (Installation dimension: 83.5mm).
21 Time
At "Weekly timer" + "Set back timer" setup
3
6
9
24°C 12
15
18
21
28°C
Operation
24°C
Time
Diagnosis check function
Example of changing sensor
Indoor unit
Day
UTY-RHK*
European switch box
Fan control *1
Operation mode Room temp. setting
JIS built-in box
*1: "Operation mode" setting is not available. It is recommend to use together with other type controller.
Two methods are available for determining the cause of failure in the event of a malfunction occurs:
Remote Sensor in the bedroom
UTY-RSK*
On / Off
83.5mm
0
60mm
28°C
24°C
Model
• Malfunction diagnosis function • Error history (Last 16 error codes can be accessed) Night
Wired remote controller
Remote sensor
The detecting point can be easily changed Wired Remote Controller in the living room
Simple installation Components are compatible with standard switch boxes. Flat back surface allows to be installed wherever it is needed.
European mounting box
JIS built-in box
Displayed temperature is set temperature.
Specifications Model name Power Supply Dimensions (H x W x D) (mm) Weight (g) DC12V is supplied by the indoor unit. K* : KY(FUJITSU), KG(GENERAL)
42
Specifications UTY-RNK* DC 12V 120 x 120 x 18 160
Model name
UTY-RSK* DC 12V
Power Supply Dimensions (H x W x D) (mm)
120 x 75 x 14 90
Weight (g) DC12V is supplied by the indoor unit.
UTY-RHK*
90
K* : KY(FUJITSU), KG(GENERAL)
43
CONTROLLER
Wireless Remote Controller
Max. controllable
16 indoor units
UTY-LNH*
IR Receiver Unit UTB-YWC
Selectable
4
Simple and sophisticated operations with a choice of 4 daily timers
daily timers
Necessary to control for all duct type by Wireless Remote Controller
• A single controller controls up to 16 indoor units.
Functions
Wiring connection
Built-in daily timer
Easy installation and operation
Select from 4 different timer programs : On / Off / Program / Sleep Program timer : The program timer operates the ON and OFF timer once within a 24 hour period. Sleep timer : The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours.
Code selector switch prevents indoor unit mix-up. (Up to 4 codes can be set.) Duct Type Indoor Unit
IR Receiver Unit Wireless Remote Controller
Specifications
Wide and precise Cooling operation/dry operation
Model name
When the sleep timer is set, the set temperature automatically rises 1˚C every hour. The set temperature can rise up to a maximum of 2˚C.
Battery Dimensions (H x W x D) (mm)
T imer setting
Weight (g)
UTB-YWC DC 12V 145 x 90 x 30 150
60min.
2˚C 1˚C
Address setting During installation work, address setting can be performed using the Wireless Remote Controller, thus eliminating manual switch setting.
Heating operation When the sleep timer is set, the set temperature automatically drops 1˚C every 30 minutes. The set temperature can drop to a max. of 4˚C.
1˚C
2˚C
Transmission line
Outdoor unit
3˚C
Indoor unit
4˚C
IR Receiver Unit UTY-LRH*B1 Cassette type indoor unit can be controlled with Wireless Remote Controller
Wireless Remote Controller
30min. 60min. 90min. Timer setting
Wireless Remote Controller
Specifications
Specifications Model name Battery Dimensions (H x W x D) (mm) Weight (g) H* : HY(FUJITSU), HG(GENERAL)
44
UTY-LNH* 1.5V (R03 / LR03 / AAA) x 2 170 x 56 x 19 85
Model name Battery Dimensions (H x W x D) (mm) Weight (g)
UTY-LRH*B1 DC 12V 193.9 x 193.9 x 31.2 140
H* : YB(FUJITSU), GB(GENERAL)
45
CONTROLLER
Group Remote Controller
Max. controllable
UTY-CGG*
remote controller groups
8
Useful functions
Max. connectable
64
Group control of indoor units with simple operation
group R.C. in a VRF network system
• Up to 8 remote controller groups can be controlled by one Group Remote Controller. • Up to 64 Group Remote Controllers can be connected in one VRF network system. • Network Convertor (UTY-VGGXZ1) is required to connect Group Remote Controllers to a VRF network system. (Network Convertor allows up to 4 Group Remote Controllers)
Indoor Unit Operation Indicators
1 Timer setting at all the connected indoor units is possible by centralized timer on the front panel.
Timer setting at all the connected indoor units is possible by centralized timer on the front panel.
With cover closed
: On : Timer operation
2 All the connected indoor
Press the ALL TIMER button to turn the timer operation on or off for all indoor units.
units can be turned on / off simultaneously by centralized ON/OFF button on the front of the cover.
Functions 3 The indoor unit can be quickly Central control
ON/OFF control
Operation Lamp
turned on and off by ON / OFF button of each indoor unit on the front of the door.
High performance and compact size ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually.
: Off : Selection
ALL TIMER Button
Weekly timer
Control up to 8 remote controller groups Single Group Remote Controller controls and monitors up to 8 remote controller groups.
This is on if any of the indoor units is operating. This flashes if any of the indoor units has malfunction(s).
Indoor Unit Name Labels
ALL OFF Button
Write the names of the indoor units on the included labels and attach them.
Press the ALL OFF button to turn off all of the indoor units.
ON / OFF Button
ALL ON Button
Press the ON / OFF button to turn the corresponding indoor unit on or off.
Press the ALL ON button to turn on all of the indoor units.
With cover open
Timer and Clock Display and setting
Displaying the Status and Controlling indoor units
Setting Display
Hotel
Transmission Display Operation Lock Display
Day Display
Guest room
ON / OFF Display Timer and Clock Display Fan Speed Display Timer Mode Display
Office room
Office & Lounge
Set Temperature Display
Lounge
Operation Mode Display Timer Mode (DELETE) Button ON / OFF Button DAY Button Select Button
Restaurant
Restaurant Network Convertor
Fan Control Button
Set Time Button
Master Control Button*1, *2, *3 PROGRAM (CLOCK ADJUST) Button Lobby
Set Temperature Button
Lobby ENTER Button 1
Child Lock Function
Group Remote Controller 1 To control office room, lounge, restaurant and lobby (8 remote controller groups)
2
Group Remote Controller
Group Remote Controller 2 To control guest room and lounge (7 remote controller groups)
" is not available for a heat pump model unless it is set up for the master indoor unit. * 1 : "AUTO * 2 : "FAN " is not available for a heat pump model " is not available for a cooling only model * 3 : "HEAT
Built-in weekly timers The weekly timer is provided as a standard function. 1. The timer can be set up for up to 4 times per day. (On / Off, operating mode, set temperature) 2. Allows separate settings for each day of the week.
Time Air conditioning ON/OFF setting corresponding to air conditioning specification needs is possible.
Temperature switching
(Peak power cut)
(Anti-freeze)
Time Switching between the cooling mode and heating mode can be set by time.
Ope. Time
Since peak power cut is performed in a planned way, setting which changes the room temperature linked with time is possible.
Stop setting
Specifications
Ope.
Temperature switching Ope.
Ope.
Cooling / Heating switching
Ope.
ON / OFF switching
Low temperature heating operation can be set to prevent freezing in cold regions at night, etc.
Time Indoor unit stop setting at operation end time is possible.
Power Supply
DC 12V
Dimensions (H x W x D) (mm)
120 x 120 x 18 200
Weight (g) DC12V is supplied by a network converter.
46
UTY-CGG*
Model name
Time
G* : GY(FUJITSU), GG(GENERAL)
47
CONTROLLER
Central Remote Controller
Max. controllable
100
Indoor units
UTY-DCG*
Max. controllable
Central control of small- and medium-sized buildings and tenants. The operation status of all connected indoor units can be viewed at a glance on a large LCD monitor to simplify individual control to batched control.
16
groups
• Individual control and monitor of 100 indoor units • 5 inch TFT color screen • User friendly view and easy operation • External input / output contact • Detachable power supply unit • Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish)
Functions Diverse control of indoor units • Weekly timer : Weekly timer can set the timer by various combinations.
• Individual control (On / Off, Mode, set Temp, Fan speed, Economy operation, Antifreeze operation)
Set temp.
Weekend
26°C
26°C
26°C
28°C
28°C
28°C
Holiday 8:00
User friendly operation Operation status monitor displays for all indoor units Easy comprehensible display and operation button
28°C
26°C
Weekday
• Remote controller prohibition (All, On / Off, R.C prohibition setting prohibits individual remote control operation from this controller
Function menu displays the items to select.
21:00 Time
Error history
• Room temperature set point upper and lower limitation
Registration indoor unit
18:00
• Automatic clock adjustment : The time setting of each controller can be set in batch automatically.
Mode, Temp, Timer, Filter) :
Function Menu
12:00 13:00
• Max 200 Errors memorize. • Suitable maintenance is possible by analysis of the error history data.
Function button 1 to 1 function button supports easy setting.
Operation guidance
Easy Installation • The control panel and power supply unit can be installed separately. • For flexibility in installation, the Control panel can be built into the wall or fix on the wall. Setting pattern 1
Ceiling Power supply unit
Wall
Group : 3F
Wall
Indoor unit registration finish
Group : Division C
Specifications Group : Tenant B
Group : Tenant C
UTY-DCG*
Model name
Power Supply Dimensions (H x W x D) (mm) Weight (g) Emergency stop function
Control panel
Control panel + Power supply unit Group : Division B
Group : 2F Group : Tenant A
Indoor unit registration start
SW BOX Group : Hallway
Group : Division A
Indoor unit registration
Setting pattern 2
System overview • It allows multiple indoor units grouping (Max.16 groups controlled) • Interlock with external device
• Automatic or manual indoor unit registration
Control Panel
Power Supply Unit
DC 5 V
100-240V, 50-60Hz, Single phase
120 x 162 x 25.7
99 x 135 x 39.2
308
355
Packing List
Control Panel / Power Supply Unit / Connecting cable, etc.
G* : GY(FUJITSU), GG(GENERAL)
48
49
CONTROLLER
Touch Panel Controller
Max. controllable
400
Indoor units
UTY-DTG*
Up to 400 indoor units can be controlled
High visibility and easy operation via high resolution 7.5 inch TFT-LCD touch panel screen
Group A
• Large-sized 7.5-inch TFT color • LCD Easy finger touch operation • Stylish shape and design to suit all application • No additional component is required for installation • Up to 400 indoor units can be controlled • Selectable 2 display types (Icon / List) in monitoring mode • Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish.
Group B
It allows multiple indoor unit grouping
Emergency stop control Air conditioner can be turned off through the external input control Emergency stop function
Functions Function
Versatility
• Up to 400 indoor units can be controlled • It allows multiple indoor units grouping • Schedule timer function is standard (20 patterns per day) • Emergency stop function(through the external input control) • Temperature upper and lower limit setting • The clock of each indoor unit correct setting
CSV format data edited by PC can be imported to Touch Panel Controller.
Individual control
Flexible grouping
Data transfer available by USB
Easy installation Touch Panel Controller is easily mounted to the wall Flat back surface allows to be installed wherever it is needed. • Correctable mechanism for tilting (horizontal) after the installation of the body
No additional component is required for installation • There is no need for the installation space of power supply adaptor and transmission adaptor etc. Schedule control
Indoor units operation monitoring
Automatic clock adjustment The time setting of each controller can be set in batch automatically.
Real size screen image
Easy operation
Easy maintenance
• Large and wide-angled LCD is easily viewable even at a distance • Easy-to-understand icon-driven Graphical User Interface (GUI) • Wide range of simple-to-understand icons
• Flat touch screen is easily cleaned • Non-glare coating on touch panel controller minimizes fingerprint marking • Easy-to-remove front cover
Specifications • Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate on-screen icon • Up-to-date status display • Background color identifies current control operation Blue for monitoring, green for operational control
Model name Power Supply Dimensions (H x W x D) (mm) Weight (g) Interface
UTY-DTG* 100-240V 50/60Hz, Single phase 260 x 246 x 54 2,150 USB 2.0
G* : GY(FUJITSU), GG(GENERAL)
50
51
CONTROLLER
Max. controllable
Software
4
VRF network systems
UTY-APGX
Max. controllable
400
System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings.
Outdoor units
• Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled. • Supports VRF S series, V series and V-ll series. • In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met.
Max. controllable
1,600
Indoor units
Functions User friendly view and operation • Click & Operate : The property is shown visually from the perspective most suitable for operation and operated accordingly (Click & Operate). You can select from among the 4 displays of site, building, floor, or list.
Click & Operate the whole building !
• Freely define groups for batched control : Indoor units can be freely grouped for simple batched control from a tree menu. Grouping by hierarchal structure, such as by section, division or department is possible.
Properties can be shown using one of the four displays of site, building, floor, or list.
Click & Operate any specified unit(s)!
Energy saving management Peak cut operation
With UTY-PEGX
Outdoor unit capacity save
Option
Option
Option
A power meter is connected to detect the total power consumption while shifting the indoor unit set temperature, set the indoor unit forced thermostat off, and taking other measures to carefully control the power Outdoor unit Forced thermostat Target power consumed while stop range off range consumption maintaining comfort and conducting control to maintain the target power consumption set for each time. The indoor units to be controlled can be freely grouped and the control Shows change in power Ideal control line (Use of level can be set. consumption by time average power consumption)
Outdoor unit capacity save switches the outdoor unit capability upper limit to suppress power consumption during hot summers and cold winters by averaging the power saving effect of each refrigerant system. You can select from 50% or more of the capacity upper limit.
Indoor unit rotation operation
Batched stop
Option
The operation of indoor units can be automatically rotated within a group in accordance with the set annual schedule to reduce power consumption while maintaining comfort. The indoor unit operation stoppage rate can be selected.
Outdoor unit capacity upper limit
Power consumption
System Controller
Time
Outdoor unit capacity control screen
Batched stop at a freely set time for a property, building, or freely set block unit can be done to prevent any air conditioning unit from being forgotten to be turned off at the end of office hours, etc. In addition, any air conditioning unit whose operation is left on can be immediately identified by the icon color for a building or indoor unit in the monitoring screen and batched stop conducted in response.
The display is easily changed by pressing the button. Batched stop Forget to turn off
Entire building stopped
Indoor unit rotation screen Site view
List view
Electricity charge apportionment Electricity charge apportionment calculation framework Suppose you want to find the power consumed by the air conditioners of each tenant from the electricity charge for each month. With electricity charge apportionment function, used energy apportionment ratio will be provided, calculating in detail the energy consumed by the units used by each tenant. This information is then used to calculate the charges for the electricity consumed for air conditioning by each tenant from the total electricity charges in the bill from the electric power company. (See figure at right) The detailed calculation takes into consideration such things as unused rooms and nighttime electricity charges and shows them in a charges calculation sheet.
Batched control of freely defined groups
Energy used by each unit is calculated
Energy apportioned by the outdoor unit to each indoor unit is calculated
Tenant A
Tenant A
Tenant B
Tenant C
Tenant B
Tenant C
System Configuration Example Building view Electric power company
Batched control of freely selected units
Electricity charges (air conditioning)
Signal transmission line
System Controller P r Powe Pow distribu ibu butio tion boardd
Outdoor unit
Click & Operate the whole floor !
The floor layout drawing can be imported to easily make the settings for the actual building.
Tenant A-1
Tenant A-2
Tenant A-3
Tenant A-4
Tenant A-5
Tenant A-6
P r Powe Pow distribu ibu butio tion boardd
Electricity charges by tenant are calculated The distribution ratio for energy used by each indoor unit is calculated and the electricity charges for the energy used by each indoor unit are calculated from the total electricity charges.
The energy used by each indoor unit and the energy apportioned by the outdoor unit are added together to calculate the total amount of energy used. Indoor unit energy used
Tenant B-1
Tenant B-2
Tenant B-3
Tenant A
Tenant B
Tenant C
Electric Bill
Electric Bill
Electric Bill
Apportioned energy
Indoor unit total energy used
3Ø, 4 wire 400V, 50Hz Tenant C-1
Tenant C-2
Tenant C-3
1Ø, 2wire 230V, 50Hz
Floor view
Click & Operate the unit !
52
53
CONTROLLER
Remote centralized control System Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and communicate with VRF system. VRF Explorer runs remotely and provides user interface and communicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a single PC or in different PCs separated by network. By using VRF Explorer software, one PC can perform central control of 10 VRF system sites with max. 20 buildings per site.
Remote central control 1 VRF Explorer can control or monitor up to 10 sites. VRF Explorer Building management company, management center, etc.
VRF Controller A maximum of 10 locations, such as offices or factories
Schedule control
Error display & E-mail notification
• Annual schedules can be set for each remote controller group / user defined group. • Start / stop, operating mode, remote controller prohibition, and temperature settings can be set up to 144 times per day at 10 minute intervals for up to 101 configurations for each remote controller group. • Settings can be made for periods straddling midnight. • Allows programming of special settings for holidays, including public holidays, for a complete year. • Low noise operation of outdoor unit can be scheduled.
Error is notified with popup message, audible sound and E-mail real time when error occurs. Error for the past 1 year are logged and can be reviewed later.
VRF Controller
On site central control
Internet or Telephone Line or LAN
Max. 4 VRF network systems per site
Operating & control record Displays the history of operation status and control.
Internet or Telephone Line or LAN
1 VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously).
VRF Explorer Central Monitoring Screen for all Properties
VRF Explorer Building Management Company A (In charge of the day shift)
VRF Explorer
VRF Explorer
Building Management Company B (In charge of the night shift)
Internet or Telephone Line or LAN
Office Management Center
VRF Explorer
VRF Controller
Diverse control of indoor units • Indoor unit operation state, operation mode, etc. are displayed • Indoor unit start / stop and operation mode switching • Temperature setting, Remote Controller prohibition.
VRF Explorer
Prohibition Setting This prohibits changes to the operation mode, temperature, start / stop, etc.
Multiple language display Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish)
Security Company
Headquarters Management Center
The following chart shows the detail requirement for an AT compatible personal computer to run System Controller. Applies for both VRF Controller and VRF Explorer PC.
Special Property Detailed Monitoring Screen
Can be used for a variety of applications
• Microsoft ® Windows ® XP SP3 (32-bit) Professional (*1) • Microsoft ® Windows ® Vista ® SP2 (32-bit) Home Premium, Business (*2) • Microsoft ® Windows ® 7 SP1 (32/64-bit) Home Premium, Professional (*2) [Supported languages] (*1) English only (*2) English, Chinese, French, German, Russian, Spanish, and Polish
Operating system
Air conditioning management for large shopping malls or the outlets of nationwide franchises
Air conditioning management of multiple buildings spread over a large site
Provides high-quality building air conditioning service
• Remote centralized management can be used for nighttime only to manage the air conditioning of multiple stores, operate air conditioning for people working overtime, and checking to see if employees forgot to turn off the air conditioning after they leave.
• Batched operation of the factory buildings on a large site can be remotely conducted from the management office of the administration building to employ power saving operation.
• Service companies that manage buildings that are empty at night after the managers leave to go home can conduct centralized remote monitoring of the building without dispatching employees to the site, which allows them to monitor the air conditioning for multiple clients.
CPU
Intel® CoreTM i3 2GHz or higher
Memory
2GB or more (Windows® XP, Vista®, 7 32-bit), 4GB or more (Windows® 7 64-bit)
HDD
40GB or more of free space
• The System Controller remote monitoring and control functions can be used to receive outsourcing business from small and medium size building owners to manage their air conditioning energy.
Display
1024 x 768 or higher resolution
• Nighttime only remote monitoring of multiple properties after the people leave can be performed for areas that require 24-hour operation, such as server rooms, to monitor for Service Companies problems.
Interface
USB port is required for each of the followings for Server PC ; • Wibu Key (Software protection key) • Echelon® U10 USB Network Interface (Required for each VRF Network) Ethernet port is required for remote connection using internet.
Accelerator
Requires the internal graphics accelerator be compatible with Microsoft® DirectX® 9.0
Software required
Adobe ® Reader® 9.0 or later
Hardware required
DVD-ROM Drive
• Multiple users via a LAN can control the air conditioning in the office, general affairs department, or janitor’s room. • The air conditioning for franchise locations nationwide can be centrally controlled from headquarters to facilitate operation status and control to save energy.
Commercial buildings
Franchises
Security Support
• The headquarters can conduct centralized remote monitoring of the company’s factories in outlying areas to improve the power saving effect for the entire company. • Controlling the operation of each building and each classroom on campus makes it possible to reduce expenses by remotely controlling those spaces in accordance with the teaching schedule.
Factories
Universities
Hospitals