Transcript
Datasheet
LAN/Length Cable Tester
TCT-2690 Pro
Introduction
2
Features
2
Specifications
3
Instructions for Operation
4
LAN Mode
4
Memory Mode
7
Low Battery Mode
8
TEL Mode
8
COAX Mode
10
TONE Mode
11
LENGTH Mode
12
SET UP Mode Note
13 14
Quality Link Connections
1
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
Datasheet
LAN/Length Cable Tester
TCT-2690 Pro
Introduction The Goldtool LAN /Length TCT-2690 Pro is designed to check , measure Length and troubleshoot the pin connections of RJ45 and F connect cables. It is ideal for testing the continuity of each pair of an LAN cable and F cable prior to installation on equipments. 1) Check Coax , type CAT5, 5e , 6 and 7 twisted cord network and trouble. 2) Check cable sequence . 3) Use TDR (time domain reflect meter), Measure length and distance, find the trouble location. 4) Find the determined open circuit, short circuit, jumper, cross or split pairs. 5) Service line test and no external adaptor is required. 6) Determine continuity and wiring pattern. 7) Low Battery indication Features 1) One person enough to complete cable continuity check. 2) Check wiring error in 5E, 6E, coaxial cable and telephone line such as open circuit, short circuit, jumper wire, reverse connection , cross talk interference or split pairs. 3) Locate the wiring or connection error. 4) Measure cable length and determine the distance of open circuit and short circuit. 5) Dynamically calibrate cable length and make length measurement as accurate as 97% . 6) Simple and easy use 144 x 64 Dots FSTN LCM Big screen to display test result clear. 7) Portable unit with long battery life. 8) Automatically time delay shut off. 9) Measure length and pair with or without far end recognizer. 10) Locate cable and there are 8 far end passive test jacks (ID No. ID1 ID8). 11) Far end recognizer with prompting voice. 12) Self checking function and automatically compensate any change in battery capacity or ambient temperature. 13) Single board computer software watchdog design and reliable operation.
Quality Link Connections
2
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
Specifications: Name
TCT-2690 Pro 144 x 64 Dots FSTN LCM
Display
LCD Module : 80 x 54 mm (valid visual field 64.78 x 33.26 mm)
Connector type
F/RJ45 (1) TEL . (2) COAX . (3) LAN . (4) TONE . (5) LENGTH . (6) SET ( 7) POWER . (8)MEMORY. (9)UP.(10)DOWN.(11)RIGHT.(12)LEFT.(13)TEST/ENTER.
Button
Cable type Shielded or unshielded, CAT-7, CAT-6, CAT-5E, CAT-5, CAT-4, CAT-3 and Coax Error status
open circuit, short circuit, jumper wire, reverse , connection or cross talk interference and split pairs Measures cable length via TDR
Measure types Checks and verifies wire map Generates four different tracing tones to help identify users Accuracy of the length measurement is ± 5 % or ±1.5 feet . Cable length length: 1~350 meters (3~1200 feet) & accuracy Up to 1000 meters Minimum cable length for testing of split pairs Power source
1 meter (3 feet)
9 Volt alkaline battery Detects a low battery condition.
Turns off Auto-off in any mode and low power consumption for long battery life automatically Input protection
Protection against excess voltage , transients ringer signal
Physical Dimension Operating Temperature: 0° to 50° C (32° to 122° F) Environmental Storage Temperature: -10° to 60° C (14° to 140° F) Humidity: 10 % to 90 % non-condensing Accessories: Note
Tool Bag x 1 pcs , F to BNC Adapter x 2 pcs , RJ45 to USB Adapter x 2 pcs , RJ45 to RJ11 Adapter x 2 pcs , ID1 ~ ID8 x 1 set .
Quality Link Connections
3
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
Instructions for Operation: Picture of power on S E L E C T 1
L A N
M O D E
2
T E L
M O D E
3
C O A X
M O D E
4
T O N E
M O D E
5
L E N G T H
M O D E
LAN Mode: Connect to Loopback connector Push LAN Key to Select LAN Mode Before Test L A N
M O D E
12345678
1) Connect one end of the cable to the Main connector, and the other end to the Loopback connector. 2) Select LAN Mode , Push LAN Key or Test Key to test . 3) Display can indicate the test result of the cable , Open , Short , Cross , Split , Fail or Pass, FTP or UTP . The wrong cable will be blinking and display FAIL , otherwise display PASS . After Test : If All Pass FTP ( STP ) Cable L A N
M O D E
L O O P
1 2 3 4 5 6 7 8 0
FTP PASS
1 2 3 4 5 6 7 8 0 0 : Shield Push KEY back to the picture of before test
Quality Link Connections
4
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
After Test : If 3,5 open UTP Cable L A N
M O D E
L O O P
1 2 3 4 5 6 7 8
2 . 9M FA I L
1 2 3 4 5 6 7 8
OPEN
The wrong cable will be blinking and display FAIL and show the length of the open cable . After Test : If 4,5 short UTP Cable L A N
M O D E
L O O P
1 2 3 4 5 6 7 8
UTP FA I L
1 2 3 4 5 6 7 8
SHOR T
The wrong cable will be blinking and display FAIL After Test : If 4,5 . 7,8 cross L A N
UTP Cable M O D E
L O O P
1 2 3 4 5 6 7 8
UTP FA I L
1 2 3 5 4 6 8 7
CROS S
The wrong cable will be blinking and display FAIL and show wrong pair After Test : If 2 , 3 split UTP Cable L A N
M O D E
L O O P
1 2 3 4 5 6 7 8
UTP FA I L
1 2 3 4 5 6 7 8
SPL I T
The wrong cable will be blinking and display FAIL 5 Quality Link Connections www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
LAN Mode: Connect to Remote Terminator ( ID No. ID1 ID8 ) Push LAN Key to Select LAN Mode Before Test L A N
M O D E
12345678
1) Connect one end of the cable to the Main connector, and the other end to the Remote Terminator. 2) Push LAN Key or Test Key 3) Display can indicate the test result of the cable ,Open ,Short , Fail or Pass ,STP or UTP & ID No. ( without Split function) The wrong cable will be flashing and display FAIL , otherwise display PASS . After Test : If All Pass UTP Cable L A N
M O D E
R E M O T
E
1 2 3 4 5 6 7 8
I
D
-
1
UTP PASS
1 2 3 4 5 6 7 8 The Remote terminator will beep . Push KEY back to the picture of before test and turn off the beep . After Test : If 3,5 open UTP Cable L A N
M O D E
R E M O T
E
I
1 2 3 4 5 6 7 8
D
-
?
2
. 9M
FA I L 1 2 3 4 5 6 7 8
OPEN
The wrong cable will be blinking and display FAIL If Fail display ID-?
Quality Link Connections
6
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
After Test : If 4,5 short UTP Cable L A N
M O D E
R E M O T
E
1 2 3 4 5 6 7 8
I
D
-
?
UTP FA I L
1 2 3 4 5 6 7 8
SHOR T
The wrong cable will be blinking and display FAIL After Test : If 4,5 . 7,8 cross UTP Cable L A N
M O D E
R E M O T
E
1 2 3 4 5 6 7 8
I
D
-
?
UTP FA I L
1 2 3 5 4 6 8 7
CROS S
The wrong cable will be blinking and display FAIL and show wrong pair Memory Mode: Push MEM Key over 3 seconds can memorize the picture of test result . And will display MR-01 for 1 second . Maximum 8 sets memory : MR-01 ~ MR-08. L A N
M O D E
R E M O T
E
1 2 3 4 5 6 7 8
M R I
D
-
0
-
?
1
UTP FA I L
1 2 3 5 4 6 8 7 Push
CROS S
KEY to display different sets memory
Push another MODE Key to go away MEM Mode . M E M O R Y
M R
-
0
1
L O O P
1 2 3 4 5 6 7 8
UTP FA I L
1 2 3 5 4 6 8 7
CROS S 7
Quality Link Connections www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
When push Test Key will display follow picture: M E M O R Y
M R
ALL
0
CLEAR
YES
Push
-
KEY to erase the memory or Push
N
8
?
O
KEY to keep the memory and back to original picture
Note : LAN Mode : 8 sets Memory . TEL Mode : 8 sets Memory . COAX Mode : 4 sets Memory . LENGTH Mode : 6 sets Memory . Low Battery Mode: When power of battery lower than 6.0 V will display follow picture: M E M O R Y
M R
-
0
1
L O O P
1 2 3 4 5 6 7 8
UTP FA I L
1 2 3 5 4 6 8 7
CROS S
TEL Mode: Push TEL Key to Select TEL Mode Before Test T E L F O R
M O D E 6
P
1 2 3 4 5 6
1) Connect one end of the cable to the Main connector, and the other end to the Loopback connector. 2) Select TEL Mode , Push TEL Key or Test Key to Test , UP/Down key select 6P , 4P or 2P 3) Display can indicate the test result of the cable , Open , Short , Cross , Fail or Pass. The wrong cable will be blinking and display FAIL , otherwise display PASS .
Quality Link Connections
8
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
After Test : If All Pass 6P T E L F O R
M O D E 6
P
1 2 3 4 5 6 PASS 1 2 3 4 5 6 After Test : If 2,4 open 6P T E L F O R
M O D E 6
P
1 2 3 4 5 6 FA I L 1 2 3 4 5 6
OPEN
The wrong cable will be blinking and display FAIL After Test : If 2,3 short 6P T E L F O R
M O D E 6
P
1 2 3 4 5 6 FA I L 1 2 3 4 5 6
S HORT
The wrong cable will be blinking and display FAIL After Test : If 2,3 cross 6P T E L F O R
M O D E 6
P
1 2 3 4 5 6 FA I L 1 3 2 4 5 6
CROSS
The wrong cable will be blinking and display FAIL and show wrong pair
Quality Link Connections
9
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
KEY to select 6P 4P
In TEL Mode Push T E L
2P .
M O D E
F O R
4
P
1 2 3 4 FA I L 1 2 3 4 T E L
OPEN
M O D E
F O R
2
P
1 2 FA I L 1 2
OPEN
COAX Mode: Push COAX Key to Select COAX Mode Before Test C O A X
M O D E
7 8
1) Connect one end of the cable to the Main connector, the other end to the Terminator connector. 2) Select COAX Mode , Push Coax Key or Test Key to test . 3) Display the cable Pass or Fail .
Quality Link Connections
10
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
After Test : If All Pass Coax C O A X
M O D E
7 8 PASS 7 8 After Test : If 7,8 open Coax C O A X
M O D E
7 8 FA I L 7 8
OPEN
The wrong cable will be blinking and display FAIL TONE Mode: Push TONE Key Select TONE Mode T O N E
M O D E
1 2 3 4 5 6 7 8
MU S I C : 1 1) Connect one end of the cable to the Main connector. 2) Select TONE Mode , Push TONE Key or Test Key to test . 3) Push 4) Push
key select different music . key select different pairs output . 11
Quality Link Connections www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
LENGTH Mode: For LAN Push LENGTH Key Select LENGTH Mode Before Test : For LAN L
E N G T H
M O D E
LAN
Ca b l e
1) Connect one end of the cable to the Main connector, the other end free or to the Loopback connector. 2) Select LENGTH Mode , Push LENGTH Key or Test Key to test . 3) Push key to display the length of each pair . After Test L
E N G T H
M O D E
LAN Pa i r 1 :
LENGTH Mode: For COAX : Push
Ca b l e 3 0 4 . 0
M
key to select COAX Cable Length Test
Before Test : For COAX L
E N G T H
M O D E
COAX
Ca b l e
1) Connect one end of the cable to the Main connector, the other end free . 2) Select LENGTH Mode , Push LENGTH Key or Test Key to test .
Quality Link Connections
12
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
After Test L
E N G T H
M O D E
COAX L e ng t h :
Ca b l e
1 0 4 . 0
M
SET UP Mode: Push SET UP Key to Select SET UP Mode Push Push
key to set key to next mode
1) Buzzer On/Off . S E T U P
M O D E
1 . Bu z z e r . . ON
OFF
The select setting will blinking . Push SETUP Key to memorize the setting and back to the picture of test 2) Backlight On/Off . S E T U P
M O D E
2 . Ba c k L i gh t . . ON
OFF
The select setting will blinking . Push SETUP Key to memorize the setting and back to the picture of test
Quality Link Connections
13
www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030
3) Length unit select . S E T U P
M O D E
3 . Un i t . . M
FT
The select setting will blinking . Push SETUP Key to memorize the setting and back to the picture of test 4) Calibrate Length . S E T U P
M O D E
4 . Le ng t h
Ad j ? TEST
KEY
1) Connect the Calibrate cable to the connector . 2) Push TEST Key to measure the length of the cable S E T U P
M O D E
4 . Leng t h
Push
-
S E T
Ad j ?
1 0 . 2FT Push
M R
-
+
key to calibrate the length key to next mode
Push MEMORY Key To Memorize the setting Push any Mode Key back to the picture of test Note : 1) Power Auto off if no touch any key in 5 minutes , except TONE Mode . 2) Power Auto off if no touch any key in 30 minutes , On TONE Mode . 14
Quality Link Connections www.telkolink.com | Perpa Ticaret Merkezi A Blok No.516 Sisli-Istanbul | Tel: 0212 3204030