Preview only show first 10 pages with watermark. For full document please download

Lanmark-5 U/utp Pvc 500m Reel

   EMBED


Share

Transcript

LANmark-5 U/UTP PVC 500m Reel Nexans ref.: N100.522 • Offers headroom to Category 5E standards • Performance guaranteed to 155MHz • Supports Gigabit Ethernet Description Application Nexans LANmark-5 cable designed to provide additional performance and bandwidth over and above the basic requirements of Category 5e. With modern high speed applications, installation effects can have a serious influence on the initial cable performance and without sufficient headroom problems can arise. The addition of transition points within the link can also lead to additional losses. Nexans LANmark-5 provides the additional headroom necessary to ensure that applications such as Gigabit Ethernet can run efficiently after installation. It is available in Grey PVC or Orange LSZH. Performance With guaranteed performance to 155MHz, Nexans LANmark-5 cables provide guaranteed additional headroom and bandwidth over and above the requirements of TIA 568-B and IEC 61156-5. Guarantees Nexans LANmark-5 cables are covered by the guarantee that they are Category 5e and by a parts and labour warranty as described in the Nexans Certified System Warranty. Moreover they come with following guarantees: • • • • • 3dB min. headroom over IEC 61156-5 and TIA 568-B Cat 5e NEXT Improved ACR Superior EMC performance 155MHz guaranteed performance When used in a full LANmark system, full LANmark D channel warranty can be obtained. Standards International ISO/IEC 11801; ISO/IEC 61156-5 National TIA/EIA-568-B.2;TIA/ EIA-568-B.2 Operating temperature, range Min. static operating bending rad. Laying operation bending rad. Ambient install temp, range (°C) -20 .. 60 °C 20.0 mm 40.0 mm 0 .. 50 °C Generated 3/2/07 - http://www.nexans.be Flame retardant IEC 60332-1 Page 1 / 4 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. LANmark-5 U/UTP PVC 500m Reel Related Information Installation: Nexans LANmark-5 cables are designed to be installer friendly. The additional performance headroom provides confidence for difficult installations. Contact Cabling Solutions Alsembergsesteenweg 2, b3 B-1501 Buizingen Belgium Phone: +32 2 363 38 00 [email protected] Operating temperature, range Min. static operating bending rad. Laying operation bending rad. Ambient install temp, range (°C) -20 .. 60 °C 20.0 mm 40.0 mm 0 .. 50 °C Generated 3/2/07 - http://www.nexans.be Flame retardant IEC 60332-1 Page 2 / 4 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. LANmark-5 U/UTP PVC 500m Reel Nexans ref.: N100.522 Characteristics Construction characteristics Type of cable Outer sheath Colour Dimensional characteristics Diameter over insulation Nominal outer diameter (mm) Approximate weight (kg/km) Conductor cross-section (AWG) Electrical characteristics Characteristic impedance Transfer impedance Transmission characteristics Coupling attenuation at 30 MHz Skew Velocity of propagation Propagation delay, max. 100 MHz Usage characteristics Category Range Component function Operating temperature, range Minimum static operating bending radius Laying operation bending radius Fire load (MJ/km) Length (m) Ambient installation temperature, range (°C) Flame retardant Packaging U/UTP PVC Grey 0.9 mm 4.9 mm 30 kg/km 24 100 Ohm 20 45 dB 45 ns/100m 68.0 % 536 ns/100m LANmark-5 LANmark-5 Cable -20 .. 60 °C 20.0 mm 40.0 mm 400 MJ/km 500 m 0 .. 50 °C IEC 60332-1 Reel Electrical Performance all values are specified at 20°C Frequency 1 4 10 16 20 31.25 62.5 100 155 Attenuation dB/100m 2.1 4.0 6.3 8.0 9.0 11.4 16.5 21.3 27.2 NEXT dB 68.3 59.3 53.3 50.3 48.8 45.9 41.4 38.3 35.5 ACR dB/100m 66.2 55.3 47.0 42.3 39.8 34.5 24.9 17.0 8.3 PSNEXT(*) dB 65.3 56.3 50.3 47.3 45.8 42.9 38.4 35.3 32.5 Generated 3/2/07 - http://www.nexans.be ELFEXT dB/100m 63.8 51.7 43.8 39.7 37.7 33.9 27.9 23.8 19.9 PSELFEXT dB/100m 61.0 49.0 41.0 36.9 35.0 31.1 25.1 21.0 17.2 RL dB 20.0 23.0 25.0 25.0 25.0 23.6 21.5 20.1 18.7 Page 3 / 4 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. LANmark-5 U/UTP PVC 500m Reel (*) Dual cable versions additionally comply to the additional PSNEXT requirements for multi-unit cables as specified in the relevant TIA and IEC cable standards. Generated 3/2/07 - http://www.nexans.be Page 4 / 4 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.