Preview only show first 10 pages with watermark. For full document please download

Layerzero Series 70 Epanel

   EMBED


Share

Transcript

Product Brochure Series 70 ePanel-2 Web-Enabled Wall-Mounted Remote Power Panel ePanel-2 Wall-Mounted Remote Power Panel Purpose ePanel: Save Space, Increase Safety & Efficiency, And Maximize Reliability ePanel Uses A Wall-Mounted Design To Maximize The Effectiveness Of Critical Floor Space Web-enabled Series 70: ePanel-2 Wall-Mounted Distribution Panels save space. ePanel is highly configurable to meet a variety of business goals, and can be installed at the end of server rows or on the walls. The ePanel utilizes the IP-20 finger-safe SafePanel™, requires Category-0 PPE, provides selective trip coordination to 35 kAIC, enables Bluetooth connectivity, contains waveform capture on every breaker, with Modbus/TCP, SNMP, HTTP web browsing protocols supported. 2 2 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. ePanel-2 Product Overview InSight™ IR Portholes to Thermal Scan Bolted Connections Two 42-Circuit SafePanel™ Panel Boards Polycarbonate Window to view Circuit Breaker Positions Guided Wireways for Organized Cabling Compression Connections at Input Feeder Circuit Breaker Designation Cards Flexible Busway for Higher Reliability Product Features Reliability Safety Power Quality Monitoring Silver Plated Terminals Sectionalized Components Waveform Capture Machined Hardware Polycarbonate Windows “Black Box” Forensic Diagnostics Convection Cooling Dead-Front Hinged Doors LCD Membrane Panel Serialized Critical Board Tracking SafePanel™ Distribution Selective Trip Coordination Guided Wireways Front-Only Installation Connectivity Ethernet Connectivity Modbus/TCP Agency Certification The Series 70 ePanel-2 is ETL and cETL listed to UL 60950 NTP Time Clock Synchronization SNMP Connectivity Certified To CSA Std C22.2 No. 107.1 Bluetooth Connectivity 3 3 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Silver Plated Terminals Provides Excellent Electrical Conductivity LayerZero utilizes silver plating on all bus joints to be able to provide the highest performance. Silver has high conductivity and low resistance which makes for a great contact. Silver Plated Ground and Neutral Connections Silver Plated Inputs 4 4 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Machined Hardware Designed To Retain Constant Torque Our systems utilize machined cap screws and engineered disc springs with a flat pressure vs deflection profile to ensure that all bolted connections maintain constant torque through the life of the product. Machined Cap Screw Engineered Disc Springs Helicoil Inserts LayerZero hardware is designed so that when bolts are tightened, they stay that way. 5 5 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Convection Cooling No Fans, Dust Filters, or Fan Fuses Fans and fan sensors are one of the most common components to fail. For maximum uptime, ePanel-2 systems do not contain any fans, dust filters to change, or fan fuses to replace. The Series 70 ePanel-2 Remote Power Panels utilizes a natural convection-cooled heat dissipation system. ePanel-2 is Convection Cooled 6 6 Series 70 ePanel-2 Brochure Louvered Vents are Available © 2014 LayerZero Power Systems, Inc. Serialized Circuit Board Tracking Serialized circuit boards We serialize and track all critical circuit boards and memory cards through our eBOSS portal, which allows customers to reference which components their machines are made from, who tested the components, as well as the ability to view notes generated from testing. Serialized components offer the ability to drill-down on prospective component failure utilizing predictive modeling techniques, so if part fails, the instance can be cross-referenced with similar parts. This preventative maintenance helps ensure maximum uptime. Critical Boards Process Power Quality Monitoring Information 7 7 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Selective Trip Coordination Selective Trip Coordination LayerZero Series 70 ePanel-2 Remote Power Panels are selective trip coordinated. Selective Trip Coordination ensures that the main breaker will remain unaffected by the branch circuit breakers in the event of a downstream fault. The Fault Current Opens the Solenoid Magnet, Causing The Contacts To Part Unequal Pressure on Each Side of The Arc Causes the Plasma Wave To Rotate Away From The Contacts The Plasma Wave is Driven into 12 Evenly Spaced Dividers The Plasma is Rapidly Cooled Transient Voltage Attempts To ReStrike The Arc, But The Plasma Is Again Pushed Into The Dividers When Sufficiently Cool, Charged Particles Recombine And The Fault Current Is Stopped Quickly & Safely Main CB does not trip Panel board critical bus outage lasts <4 msec. Critical loads continue to operate Faulted branch CB trips in <4 msec Downstream fault High Speed Branch Circuit Breakers With Selective Tripping 8 8 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Sectionalized Components Sectionalized Components Help Maximize Operator Safety Operators are well-protected from exposed connections. There is a physical separation between the main circuit breaker(s) and branch circuit breakers. All connections are optically isolated to minimize risk. Polycarbonate windows are utilized to permit visibility and maximize operator safety. Energized parts are all insulated, covered, recessed, &/or internally mounted for safer operation of the unit. In addition, sections that isolate machine components are insulated. Inputs/Main Circuit Breakers Branch Distribution Inputs/Main CBs Isolated from Distribution 9 9 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Polycarbonate Windows View CB Positions With Dead-Front Doors Closed Our Series 70 product line was inspired by NFPA-70E, to help data centers drastically reduce the risks of their energy distribution systems. SafePanel circuit breaker positions can be viewed with the dead-front door closed. CBs Viewable Through Polycarbonate Windows 10 10 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Dead-Front Hinged Doors Dead-Front Hinged Doors Maximize Operator Safety The Series 70 ePanel-2 utilizes dead-front hinged doors. Dead-Front hinged doors allows for operation of circuit breakers without risk to the operator. Dead Front Doors Permit CB Functionality while Protecting Operators 11 11 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. SafePanel™ Distribution The LayerZero SafePanel™ The Series 70 ePanel features an IP-20, finger-safe panel board, meaning that the opening will not allow ingress of ½” (12.5mm) diameter probe, for maximum operator safety. An arc can form as two live conductors are separated – such as the removal of a circuit breaker from a panel board. The SafePanel design ensures that a potential arc would be contained in the connection well so that even if a branch breaker were to be removed, the arc would be contained in the connection well. Insulated with the components deeply isolated, removal of the breaker is safe and easy. 15/16” IP-20 Rated Finger-Safe Ingress Isolated, Non-Conducting Brass Screws ePanel-2 400 A Circuit Breaker Installation Process 12 12 The Protective Cover Is Removed The Breaker Is Inserted Into The Opening The Breaker Snaps Into The DIN Rail The Breaker Is Secured With An Isolated, Non Conducting Screw Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Guided Wireways Guided Wireways Help keep cables and wiring organized with our guided wireways and cable clips. Clips Help Manage Cables Guided Wireways Help Facilitate Organized Cabling 13 13 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Front-Only Access Front Only Access Enhances Critical Load Reliability The Series 70: ePanel-2 can be installed, operated, diagnosed and maintained from the front. The dead-front panels are hinged, and side or rear covers never have to be removed. Unhinged covers can be bulky and unwieldy, and operator error during removal and replacement of covers has been known to cause mishaps and compromise load reliability. A safe, non-invasive operation and maintenance regime results in a higher reliability of the critical load. 14 14 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Ethernet Connectivity Open protocols LayerZero utilizes open source protocols for its communications, which allows for: • An enhanced ability to customize software • Flexible software development options • Lower total cost of ownership (no per copy fees) • Elimination of vendor lock-in • No proprietary limitations • Provides a stable, well developed foundation The control path for the communications system gathers information from all aspects of the machine, isolated by fiber optics. Connectivity to a WAN allows for the information to be accessible from any location, offering a variety of monitoring options. Series 70 ePanel Standard Ethernet Modbus/TCP • Panel Setup • Meters • Alarms http:// through a standard web browser • Meters • Alarms • Waveforms • History/Event Log • Diagnostics Dry Contacts Simple Network Management Protocol (SNMP) • Alarms • Alarms A Flexible Approach A variety of connectivity options provide operators with the ability to adapt LayerZero systems to fit existing networks without the complications of working with closed, proprietary systems. The Series 70 ePanel-2 is designed to make it easy to transfer and exchange power usage data, which is very useful towards making smart corporate decisions and policies. 15 15 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Bluetooth Connectivity Bluetooth Helps Keep Panel Board Names Up-To-Date Coordinate efforts to keep panel board naming conventions accurate and up-to-date with Bluetooth connectivity. In critical facilities, Facilities typically install the physical circuit breakers, while IT workers manage naming of panel designations. With Bluetooth connectivity, the naming of circuit breakers can be taken care of at the point-of-impact, bringing together the efforts of facilities and IT for more accurate panel names. 16 16 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Waveform Capture Real-Time Waveform Capture The Series 70 ePanel-2 provides real-time waveform capture functionality, enabling operators the ability to obtain a fingerprint of the power quality at any given moment. Waveform captures are available for both the main and branch circuit breakers, every pole of every breaker. 17 17 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. “Black Box” Forensic Diagnostics “Black box” forensic diagnostics The black box capabilities of LayerZero equipment are extremely useful for analyzing root cause analysis, enabling operators to pinpoint exactly where a fault occurred. “Black box” forensics provide successive event information with ten microsecond resolution, supplies a brief snapshot of the event with a lead-in for further inquiry, and furnishes a real-time status indicator of all machine parameters at the time of the event. “Black box” event history is one of the most useful recording schemes in the mission critical power machine industry. LayerZero Black Box Forensics Can Help You: • Reconstruct The Sequence of Events • Find the Root Cause of Power Quality Incidents • Record Snapshots of the Power 18 18 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. LCD Membrane Panel LCD Information The front mounted LCD panel provides operators with a great deal of information, including: • Alarms • Main 1 Basic Meters • Main 2 Basic Meters • Branch Amps Meters • Branch kW Meters • Main 1 Derived Meters • Main 2 Derived Meters • Branch Derived Meters 19 19 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Technical Specifications Electrical Configurations Mechanical Configurations ePanel 2-2: 225A, 84-circuit 225A, 100% rated fixed mount main CB 225A, 100% rated plug-in main CB option ePanel 2-4: 400A, 84-circuit 400A, 100% rated fixed mount main CB 400A, 100% rated plug-in main CB option Voltage configurations: 480V, 3-wire: 14kAIC 480Y/277V, 415Y/240V, 400Y/230V, 380Y/220V: 14kAIC 208Y/120V: 25kAIC Enclosures sized to accommodate 75 °C feeders ETL Listed to: UL 67 and CSA C22.2 No. 29-M1989 Product Name ePanel-2-2 ePanel-2-4 Panel Board & Main CB Rating Main CB Mounting 225A Fixed 400A • Wall-Mounted • Door-in-door construction » Hinged inner doors for safety » Two separate inner doors a. Branch circuit panel inner door for normal panel board loading and wiring b. Main Circuit breaker inner door for installation and maintenance access » Hinged outer door • Viewing window on outer door for branch circuit breakers and main circuit breaker position view • Viewing windows on doors • Top main cable access • Top/Bottom branch cable access • Circuit identification tags on panel board • Plug-in main circuit breaker is optional • Input feeder connection options: » Single mechanical lug » Dual mechanical lug (accepts two conductors per phase) » NEMA 2-hole studs for long-barrel, 2-hole compression lugs Enclosure Width Enclosure Height Enclosure Depth Input Feeder Termination Single, Mechanical Dual, Mechanical Two-Hole, Compression 47"W 80"H 80"H 80"H 10.5"D Fixed 47"W 80"H 80"H 80"H 10.5"D 225A Plug-in 47"W 80"H 80"H 80"H 10.5"D 400A Plug-in 47"W 80"H 80"H 80"H 10.5"D Power Monitoring Option Connectivity Option To support the total needs of an increasingly information centric critical power distribution environment, the Series 70 ePanel may be optionally equipped with a branch circuit level and panel board main circuit power monitoring. The Panel Board Branch Power Monitor allows site management to monitor power consumption. This provides information that is increasingly vital to the revenue model of many data processing units. Each panel board is equipped with the ability to communicate measured information remotely to the Building Management System using open protocols. The connectivity is Ethernet based and the design is plugand-play. Each panel board is assigned a fixed IP address. Information is accessed via: In addition to measuring the main bus voltage of the panel board and delivering Waveform Capture upon anomaly of main bus voltage, the power monitor measures the following parameters for each of the 42 branch circuits in a given panel board: • Web-browser (http://) service 20 • MODBUS TCP/IP service • SNMP service • Bluetooth Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Series 70 ePanel-2 Technical Characteristics Mechanical Characteristics Main CB Mounting Dimensions Fixed Plug-In Panel Board & Main CB Rating Enclosure Height Enclosure Width Input Feeder Termination Single, Mechanical Dual, Mechanical Two-Hole, Compression Enclosure Depth 225 A 400 A 225 A 47”W 80”H 10.5”D 400 A Enclosure Mounting Wall-Mounted Frame Construction Welded Frame Enclosure Gauge 16 Gauge or greater Electrical Connections Flexible Busway, Silver-Plated Solid Busbar Color Textured Powder Coat White (RAL 7035), Black, Custom Seismic Floor Anchors Optional Seismic Floor Stand Optional Sectionalization Engineered Composite Insulation, Dead Front Doors Circuit Breaker Identification Labels Viewable Through Polycarbonate Window Electrical Characteristics Input Feeder Termination Single, Mechanical; Dual, Mechanical; Two-Hole, Compressoin Input Current 225 A; 400 A Voltages 480 Y/277 V; 415 Y/240 V; 400 Y/230 V; 380 Y/220 V: 14 kAIC; 208 Y/ 120 V: 25 kAIC Number of Output CBs 84-Circuit Frequency 50 Hz, 60 Hz Poles 3-pole, 4-pole Phases 3-Phase, 3-Wire (Input); 3-Phase, 4-Wire + Ground (Output) Neutral Rating 100%, 200% Circuit Breaker Mounting Type None, Fixed, Plug-In Distribution SafePanel™ Distribution Power Quality Monitoring Waveform Capture Local Display, Remote Display via Web Browser Voltmeter Input sources and Output, for each phase Ammeter Input sources and Output, for each phase Metering Apparent Power, Real Power, Power Factor, Output Total Harmonic Distortion CB Status Indicator Open/Closed/Tripped Circuit Breaker 21 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. Series 70 ePanel-2 Technical Characteristics Operational Characteristics Password Protection User Configurable Roles Cooling Convection Cooling Cable Access Top/Bottom Service Access Front and Side Access Noise & Interference Isolation Optical Fiber IR Scan Port Type InSight™ IR Portholes Display Type LCD Membrane Backup Monitoring System LED (Light Emitting Diodes) Connectivity Meters Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary) Alarms Local Display, Ethernet, Modbus/TCP, http via Web Browser (Non-Proprietary) Summary Alarm Dry Contacts Waveforms Local Display, Ethernet, http via Web Browser (Non-Proprietary) History/Event Log Local Display, Ethernet, http via Web Browser (Non-Proprietary) Diagnostics Local Display, Ethernet, http via Web Browser (Non-Proprietary) Time Synchronization Network Time Protocol (NTP) Standards Conformance CSA C22.2 No 29-M1989 IEEE C62.41 and 45 NEMA AB-1 NFPA 70E UL ETL Listed to UL 67 Contact LayerZero for custom sizes and designs. 22 Series 70 ePanel-2 Brochure © 2014 LayerZero Power Systems, Inc. LayerZero Power Systems, Inc. 1500 Danner Drive Aurora, OH 44202 U.S.A. Learn more at www.LayerZero.com © 2014 LayerZero Power Systems, Inc. LayerZero Power Systems, LayerZero.com and the LayerZero logo are registered trademark of LayerZero. All product specifications are subject to change without notice. 23 Series 70 ePanel-2 Brochure Rev. 5/14 © 2014 LayerZero Power Systems, Inc.