Transcript
LBH-DVI-EAD LINK BRIDGETM HDBASET DVI VIDEO CONVERTING TRANSMITTER SYSTEM
BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed as a result of their use or application. All rights reserved. ©2013 Broadata Communications, Inc.
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
CAUTION This symbol alerts the user that important literature concerning the operation of this unit has been included. Therefore, it should be read carefully in order to avoid potential problems. Manufacturer: This symbol shall be accompanied by the name and address of the manufacturer adjacent to the symbol, and the date of manufacture where the date shall be located adjacent to the symbol. SN Serial Number: Indicates the manufacturer’s serial number so that a specific medical device can be identified. CLASS II ME EQUIPMENT
Functional Earth Terminal.
Caution, review manufacturer’s documentation for instructions. WARNING: No modification of this equipment is allowed. DO NOT remove cover (or back). There are no user serviceable parts inside. Refer servicing to qualified service personnel.
Product Safety: This product meets the medical safety requirements. North American Safety Compliance: ANSI/AAMI ES60601-1:2005/(R):2012 Medical electrical equipment – Part 1: General requirements for basic safety and essential performance CAN/CSA-C22.2 No. 60601-1-08 (3rd Ed.) Medical electrical equipment – Part 1: General requirements for basic safety and essential performance WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY
Broadata Technical Support,
[email protected]
3
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
EEC Safety Compliance: These products meet the requirements of EN 60601-1:2005 so as to conform to the Medical Device Directive 93/42/EEC (general safety information) as amended by 2007/47/EC. This equipment is energized from 100-240 VAC 50 / 60 Hz power source. It is the responsibility of the installer to ensure that the equipment is installed in accordance with applicable hospital, local and national electrical codes. An additional multiple socket-outlet or extension cord shall not be connected to the system To power unit down, remove power cable from unit or disconnect power cord from power receptacle. The power supply or the appliance coupler is the only recognized disconnect device, disconnect the power supply from the AC mains. Do not position the equipment so that is it is difficult to access the appliance coupler. Class II Medical System No Applied Parts IP20 LBH Power Supply: 80275-2401
[email protected] Power Supply For medical applications must use: MPS-24V 30W-BP (BCI-80275-2475): BridgePower 24V D/T 2.5mm 100240V~, 50-60Hz 1.0A LCK MED MPS-24V-50W-GLT (BCI-80275-2421): GlobTek 24V D/T 2.5mm 100-240V~, 50-60Hz 1.6A LCK MED Power Cord: Use a hospital grade power cord with the correct plug for your power source. Recycling: Upon termination of the service life of this product please return unit to the manufacturer for proper waste disposal, or follow local governing ordinances and recycling plans regarding the recycling or disposal of this equipment , or contact the Electronic Industries Alliance (www.eiae.org). Declarations of Conformity FCC and Council Directives of European Standards: This device complies with Part 15 of FCC rules and 93/42/EEC of the Council Directives of European Standards Directive as amended by 2007/47/EC. Operation is subject to the following two conditions: (1) This device may not
4
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable results. 1. Use the specified cables with this device so as not to interfere with radio and television reception. Use of other cables and / or adapters may cause interference with other electronic equipment. 2. This equipment has been tested and found to comply with the limits pursuant to FCC part 15 and CISPR 11. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. IEC: This equipment has been tested and found to comply with the limits for medical devices to the IEC 60601-1-2. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. FCC, Council Directives of European Standards and IEC: There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult your dealer or an experienced radio/TV technician for help. Accessory equipment connected to this monitor must be certified according to the respective IEC Standards (i.e., IEC 60950-1) for data processing equipment and IEC 60601-1 for medical equipment). Anyone who connects additional equipment to the signal input part or signal output part configures a medical system, and is therefore responsible that the system complies with the requirements of system standard IEC 60601-1-1. Whoever is responsible for securing the monitor to a system needs to insure that the mounting equipment used with this display complies to IEC standard 60601-1. If in doubt, consult the technical services department or your local representative.
Broadata Technical Support,
[email protected]
5
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
About this Manual This manual is designed to assist the user with installation, setup and operation of the LBH-DVI-EAD-T/R products. The functional descriptions in this manual are representative of: 60722-0500 LBH-DVI-EAD-T 60722-0600 LBH-DVI-EAD-R 60722-2500 LBH-DVI-EAD-T-WP 60722-2600 LBH-DVI-EAD-R-WP Manual ID Number: 60000-LBHDVIEAD-080714 The combination of the LBH-DVI-EAD T/R video system and the power supply is a medical electrical system Intended Use and Contraindications Intended Use: This device is intended for use in a medical environment to transmit high quality video and graphic images . Suitable for Continuous Use. All parts of the system are suitable for use within the patient environment Contraindications: This device is not intended for life support applications. Not suitable for use in an oxygen rich environment Operational Failure Conditions and Mitigation Operational Failure: End user cannot view the video data from a connected video source due to Incompatibility with video source equipment, or degraded video data, or the unit cannot be powered on. Mitigation: Bypass the device by connecting via a failsafe cable from the output of the video source directly to a monitor. For mission critical applications, we strongly recommend that a replacement unit be immediately available.
SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical spikes, surges, electric shock, lightning strikes, etc. Use of surge protection systems is highly recommended in order to protect and extend the life of your equipment.
6
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
TABLE OF CONTENTS 1.0 PRODUCT DESCRIPTION .............................................6 2.0 SETUP .............................................................................. 9 2.1 MOUNTING ......................................................................9 2.2 CABLING AND CONNECTORS ...................................... 9 2.2.1 ELECTRICAL CABLE CONNECTIONS ..................... 10 2.2.1.1 DVI VIDEO INTERFACE ............................................ 10 2.2.1.2 AUDIO INTERFACE .................................................. 11 2.2.1.3 SERIAL DATA INTERFACE ....................................... 12 2.2.1.4 STATUS LED’S ......................................................... 13 2.2.2 CAT-5e/6 CABLE CONNECTION ............................... 13 2.3 DC POWER CONNECTION ......................................... 15 2.5 IN-WALL POWER/CAT-5e/6 WIRING INSTRUCTION 16 3.0 OPERATION ................................................................... 19 4.0 MAINTENANCE AND TROUBLESHOOTING .............. 20 4.1 MAINTENANCE ............................................................. 20 4.2 TROUBLESHOOTING .................................................. 20 5.0 SPECIFICATIONS .......................................................... 22 6.0 SERVICE PROCEDURE ............................................... 24 6.1 REPLACEMENT POLICY ............................................. 24 6.2 RETURN AND REPAIR SERVICE ................................. 24 7.0 LIMITED WARRANTY .................................................... 25
Broadata Technical Support,
[email protected]
7
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
1.0 PRODUCT DESCRIPTION The LBH-DVI-EAD Series is a high performance, low cost, miniature, Link BridgeTM HDBaseT DVI Transmission System. It carries one (1) unidirectional DVI video, one (1) unidirectional embedded stereo audio and two (2) bi-directional RS-232 and one (1) bi-directional IR through one CAT-5e/6. The TX or RX unit can power the opposite side over the CAT-5e/6 cable, via PoH (Power Over HDBT). This unique transmission system lets your digital flat panel display extend at 4K2K Ultra HD and WUXGA (1920x1200 @ 60Hz) or 720p/1080i/1080p HDTV video resolution. No user adjustment is required for the LBH-DVI-EAD system due to the use of advanced digital HDBT transmission system technology with zero compression and zero bit reduction. This allows for a quick and easy setup, offering trouble-free operation for many years to come. In addition, the LBH-DVI-EAD transmitter (or receiver) is compatible with our LBH-EAD Series receiver (or transmitter). This makes both HDBT transmission and HDMI/DVI/VGA/YPbPr/SV/CV/SDI conversion in one single system setup. The LBH-DVI-EAD comes with either a standalone miniature enclosure or a Decora wall-plate packaging. The units are easily monitored by power and link LED indicators. Figures 1-1, 1-2, 1-3 and 1-4 illustrate the front and rear panels of the LBH-DVI-EAD-T and LBH-DVI-EAD-R units.
8
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
FRONT PANEL (STANDALONE)
HDCP
Out
DATA SPDIF
2
1
5
4
Data In
2
1
2
1
SPDIF In
In
L/R
IR
PWR/ LINK
Data Out
DATA
Power Link LED
DVI IN
3
SPDIF
AUDIO L/R
LBH-DVI-EAD-Tx
DVI In
Audio In
Out
DATA
HDCP
SPDIF
2
1
5
4
Data In
2
1
2
1
SPDIF Out
In
L/R
IR
PWR/ LINK
Data Out
DATA
Power Link LED
DVI OUT
3
SPDIF
AUDIO L/R
LBH-DVI-EAD-Rx
DVI Out
Audio Out
Figure 1-1 LBH-DVI-EAD-T/R Front Panel
REAR PANEL (STANDALONE)
LINK +24VDC 1.5AMP
Power Connector
CAT-5e/6 Output Connector
Figure 1-2 LBH-DVI-EAD-T/R Rear Panel Broadata Technical Support,
[email protected]
9
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
FRONT PANEL (WALL PLATE)
Power Link LED
Power Link LED
PWR/LINK
PWR/LINK
SPDIF
SPDIF HDCP
DVI In
DVI IN SPDIF
HDCP
DVI Out
SPDIF In
SPDIF
L /R
Data/IR Out Data/IR In
5
2
4
1
IR 3 2 1
L /R
Audio Out
L/R
L/R
Audio In
D
D
Out
SPDIF Out
DVI OUT
AUDIO IN
Out
Data/IR Out
LBH -EAD 2 1 -Tx
5
2
4
1
IR 3
Data/IR In
2
2
1
1
AUDIO OUT
LBH -EAD -Rx
In DATA
In DATA
Figure 1-3 LBH-DVI-EAD-T/R-WP Front Panel REAR PANEL (WALL PLATE)
Power Connector
+24V
CAT-5e/6 Connector
Figure 1-4 LBH-DVI-EAD-T/R-WP Rear Panel 10
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
2.0 SETUP LBH-DVI-EAD-T (or LBH-DVI-EAD-R) is a transmitter or receiver and they can be paired with any DVI/HDMI centric LBH receiver (such as LBH-DVI-R). One LBH-DVI-EAD-T transmitter unit is located at the near-end and connected through one CAT-5e/6, to the LBH-DVI-EAD-R receiver located at the far-end of the link. Figure 2-1 depicts a typical installation for the LBH-DVI-EAD-T/R.
Figure 2-1 LBH-DVI-EAD-T/R Setup
2.1 Mounting Before installing the units into your housing, make sure there is enough space to pull and connect both the electrical and CAT-5e/6 transmission cables without stressing them beyond the manufacturer’s limitations (also known as the minimum bend radius).
2.2 Cabling and Connectors In order to setup the LBH-DVI-EAD-T/R properly, make sure to observe the following instructions when installing the proper cables. The LBH-DVI-EAD-T/R requires two parts to the cabling setup, the electrical and the CAT-5e/6 transmission.
Broadata Technical Support,
[email protected]
11
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
2.2.1 Electrical Cable Connection The three available cable connections on the electrical side are for DVI video, audio and data connections. Follow the proceeding instructions in order to properly install your electrical connections.
2.2.1.1 DVI Video Interface The DVI video connection is the DVI plug connectors for video input and output ports. Use the following instructions to properly connect your component video as illustrated in Figure 2-2. 1. Connect the LBH-DVI-EAD-T (Transmitter) unit’s DVI video input port to the user’s DVI video source with the appropriate DVI cables.
HDCP
Out
DATA SPDIF
2
1
5
4
2
1
2
1
In
L/R
IR
PWR/ LINK
DATA
2. For the receive unit, connect the LBH-DVI-EAD-R (Receiver) DVI video output port to the user’s DVI video receivers with the appropriate DVI cables respectively, as illustrated in Step 1.
DVI IN
3
SPDIF
AUDIO L/R
LBH-DVI-EAD-Tx
User’s DVI Video Source
PWR/LINK SPDIF HDCP
DVI IN
User’s DVI Video Source
SPDIF
L /R
L/R
D
Out 5
2
4
1
IR 3 2
2
1
1
AUDIO IN
LBH -EAD -Tx
In DATA
Figure 2-2 Video Connection 12
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
2.2.1.2 Audio Interface The audio interface supports single stereo channel high fidelity transmissions. One stereo channel is transmitted in one direction. Line-level audio signals are connected to the LBH-DVI-EAD units. The following steps illustrate the installation procedures for audio devices.
2
1
2
1
In
L/R
DVI IN
5
4
3
2
1
PWR/ LINK
HDCP
Out
DATA SPDIF
2
1
5
4
2
1
2
1
In
L/R
IR
Out
DATA SPDIF
DATA
HDCP
IR
PWR/ LINK
SPDIF
AUDIO L/R
DVI OUT
Figure 2-3a Audio input to LBH-DVI-EAD unit
3
SPDIF
AUDIO L/R
LBH-DVI-EAD-Tx
User’s Audio Output
DATA
To send audio signals, label and connect one stereo audio-jack cable to the “AUDIO OUTPUT” connector and the line level audio receiver, connect the other cable to the front panel stereo jack connector labeled “AUDIO IN” (see Figure 2-3a and 2-3b) to the line level source.
LBH-DVI-EAD-Rx
User’s Audio Input
Figure 2-3b Audio output to LBH-DVI-EAD unit
Broadata Technical Support,
[email protected]
13
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
2.2.1.3 Serial Data Interface Each LBH-DVI-EAD unit can be used for RS-232 and IR interface. RS-232/ IR Data The LBH-DVI-EAD transmits two channels of data signals. Follow the procedures for installing data terminal devices. 1. Label and connect one serial data cable to the user’s RS-232 or IR device. 2. Connect the other end of this cable to the front panel data terminal block connector on the LBH-DVI-EAD (see Figure 2-4).
Figure 2-4 RS-232/IR Terminal block pinout
Figure 2-5 IR Cable pinout 14
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
2.2.1.4 Status LED’s Additional status LED’s are provided for the user to indicate the presence of HDCP video, audio presence and data presence. These are to assist the user in identifying right from the front panel whether a given signal is present for transmission and aid in the troubleshooting process if a given signal is missing.
2
1
2
1
In
L/R
DVI IN
5
4
3
2
1
PWR/ LINK
HDCP
Out
DATA SPDIF
2
1
5
4
2
1
2
1
In
L/R
IR
Out
DATA SPDIF
DATA
HDCP
IR
PWR/ LINK
Data in and Data out LED: It will be on when the unit detects data signal.
SPDIF
AUDIO L/R
DATA
HDCP LED: Will be solid LED when video input has a HDCP. It will blink when video input does not have HDCP.
DVI OUT
LBH-DVI-EAD-Tx
3
SPDIF
AUDIO L/R
LBH-DVI-EAD-Rx
SPDIF & L/R detect LED. It will be on when the unit detect the audio input signal.
2.2.2 CAT-5e/6 Cable Connection Follow the ensuing instructions on installing and connecting the CAT-5e/6 links: 1. Ensure the power is off before proceeding with the CAT-5e/6 cable installation. 2. It is recommended to use shielded CAT-5e/6 cabling. 3. Connect the CAT-5e/6 from one unit to the other connecting the near end LBH-DVI-EAD-T unit’s HDBT port to the far end of the LBH-DVI-EAD-R unit’s CAT-5e/6 RX port as illustrated in Figure 2-6.
Broadata Technical Support,
[email protected]
15
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
LINK
LBH-DVI-EAD-T
+24VDC 1.5AMP
LINK
LBH-DVI-EAD-R
+24VDC 1.5AMP
LBH-DVI-EAD-T-WP
+24V
+24V
LBH-DVI-EAD-R-WP
Figure 2-6 CAT-5e/6 Connection
16
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
2.3 DC Power Connection Congratulations! You are now ready to power up the LBH-DVI-EAD and set up your network connection. In order to make sure that you have a proper installation, please observe the following: 1. Your AC jack has power. 2. The 24VDC power supply is working. 3. Your electrical system has proper grounding (this ensures that your power supply does not suffer from voltage variations). 4. Power Surge Protection. This is optional, but highly recommended. A UPS system provides voltage regularity as well as prevents spikes from occurring, thus protecting your LBH-DVI-EAD from sensitive voltage conditions. The LBH-DVI-EAD derives power from an external 24VDC power supply. This power supply is a AC/DC adapter, 100-240 VAC, 50-60 Hz, at 1.5A. This power supply comes standard for the LBH-DVI-EAD unless otherwise specified. If you have any problems or concerns, regarding the installation, make sure that you have taken the proper steps to ensure a proper power connection. Otherwise, feel free to contact us for any questions you may have.
Broadata Technical Support,
[email protected]
17
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
2.4 In-Wall Power/CAT-5e/6 Wiring Instruction The in-wall power/CAT-5e/6 installation for the LBH-DVI-EAD-WP (wall plate version) must conform to national and local electrical codes, e.g., UL junction boxes shall be used and DC power source shall not exceed product rated range (+24VDC @ 1.5A). Follow the following steps for power/CAT-5e/6 installation: 1. As shown in Figure 2-7, feed both CAT-5e/6 and power cables through the opening of the wall box, and secure the cables with cable clamps to provide strain relief. 2. Terminated CAT-5e/6 with RJ45 connector to be directly plugged into the RJ45 connector port of the LBH-DVI-EAD-WP units (see Figure 2-6). 3. Before connecting power wire to the LBH-DVI-EAD-WP unit, make sure power supply is off. Prepare the Positive (+24V) and Negative (GND or +24V return), and chassis ground (CHASSIS to earth ground) tip of the power wire as shown in Figure 2-8 to be directly plugged into the captive screw +24VDC connector of the LBH-DVI-EAD-WP units (see Figure 2-7). Make sure the polarity of the connection is correct. Insulate any exposed wire shields to prevent short circuits.
18
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
Wall
Clamp Junction Box
LBH-DVI-EAD-WP Unit
Power Wire
+24V GND
CAT-5e/6 Cable Link Port
Figure 2-7 In-wall CAT-5e/6/power cable installation
Captive Screw Connector
+24V
GND
+ _
Figure 2-8 Power Connection
Broadata Technical Support,
[email protected]
19
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
Note 1: During installation, the installer may need to connect the power supply output to an appropriate Listed NEC type cable before it is routed behind a wall. Simply routing the power supply output cable behind a wall will most likely not comply with applicable installation requirements. Unit should only be powered by a power source that is Listed to the Medical standard (ANSI AAMI ES 60601-1/EN 60601-1: 2005), Class 2, LPS Power Source that is double insulated from mains. Note 2: The installation shall be in accordance with the applicable provisions of the National Electrical Code ANSI/NFPA 70, Article 725 and the Canadian Electrical Code, Part 1, Section 16. Note 3: The power supply shall not be permanently fixed to the building structure or similar structures. Note 4: The power supply shall not be located within environmental air handling spaces or within the wall cavity. Note 5: The power supply is to be located within the same vicinity as the A/V processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium or desk.
20
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
3.0 OPERATION After the installation procedure is completed, the units are ready for operation. To operate the LBH-DVI-EAD units, simply apply power as indicated in the previous sections. The following describes the LED activity.
LED Indicator PWR/LINK
Description When power is connected, this LED turns RED. When power and link are on, this LED turns GREEN
HDCP
It will be a solid BLUE LED when video input has a HDCP. It will blink when video input does not have HDCP
L/R
GREEN LED will be on when unit detects the audio input signal
SPDIF
GREEN LED will be on when the unit detects the SPIF input signal
DATA
GREEN LED will be on when the unit detects data signal
Table 1 LED Indicator
Broadata Technical Support,
[email protected]
21
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
4.0 MAINTENANCE AND TROUBLESHOOTING 4.1 Maintenance There is no operator maintenance, however, observe the following light indicators to make sure that the unit is working properly:
4.2 Troubleshooting If the LBH-DVI-EAD units do not operate properly after installation, check for possible cable breaks, loose connections, and incorrect cable connections. If problems persist that may be fiber related, contact BCI at 1-800-214-0222 for further assistance. For electrical problems, perform the following troubleshooting procedures: 1. If the POWER indicator is OFF, check for the following: a. The line cord is plugged into the unit and your outlet has power. 2. If the POWER indicator is ON, but the Link indicator is OFF, check for the following: a. Make sure the appropriate CAT-5e/6 are being used. b. Cable and RJ45 connectors are not broken. c. For each unit, the transmit (TX) cable is connected to the other unit’s receiver (RX). 3. If the POWER indicator and HDBaseT Link indicator are ON, but the audio/video channels are not operating, then: a. Check to see that the attached user equipment is turned on.
22
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
b. Both ends of the link are connected to the corresponding equipment and to the same corresponding channel port. c.
Cable connections at both the video/audio channels are securely fastened to each connector. Turn the power off, then back on to reset the link.
Broadata Technical Support,
[email protected]
23
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
5.0 SPECIFICATIONS Video Resolution
Up to 1080p@60Hz or 4K2K and 1920x1200@60HZ
Connector
DVI Female Plug
Protocol
DDC/EDID/HDCP Capable
Audio Channel Capacity
1 Stereo
Operating Mode
Unbalanced (Stereo Audio), Unidirectional
Input/Output Impedance
10k/50 Ohms (Stereo Audio)
Max. Input/Output Level
5 dBu/4Vpp (Stereo Audio) Magnitude Freq. Response 20Hz to 20kHz @ -3dB THD+N
>70 @ 1k Hz (Stereo Audio)
Connector
3.5mm Stereo Jack
Serial Data Channel Capacity
2 RS-232/1 IR
Signal Format Data Rate Connector
RS-232/IR Up to 57.6kbaud Terminal Block
Transmission Cable Type
CAT-5e/6 Shielded
Number of Cables
1
Connector
RJ45
24
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
Physical Dimension Standalone Wallplate
4.17”(W) x 4.1”(D) x 1.1”(H) 1.75”(W) x 2.70”(D) x 2.81”(H)
Power Level (max.)
+24VDC @ 1.5A
Operating Temperature
0 to +40oC
Humidity
0 to 95% RH, non-condensing
Max. Dew Point
28 C
Elevation
70kPA to 106kPA (0 m to 3050m)
The permissible storage and transport conditions are; • • • •
Temp: -25 to +70R”C Humidity: 0-95%RH non-condensing Altitude: 0 to 4000m Atmospheric Pressure: 50 to 106kPa
LBH-DVI-EAD-T
HDBT Transmitter, CAT-5e/6
DVI
1A
LBH-DVI-EAD-R
HDBT Receiver, CAT-5e/6
2 RS-232/1-IR
Add -WP for Wallplate configuration Add -CH for LBH-CH Chassis mounting kit Add -UPS for International Universal Power Supply
Broadata Technical Support,
[email protected]
25
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
6.0 SERVICE PROCEDURE 6.1 Replacement Policy Standard products found defective on arrival (DOA) will be replaced, based on availability, within 24 to 48 hours anywhere in the U.S. Please call Customer Service at 800-214-0222 for information.
6.2 Return/Repair Service The LBH-DVI-EAD System contains no user serviceable components. If you have a problem with your unit, please contact the Customer Service Department. To facilitate our return/repair processing please contact Broadata Communications, Inc. to obtain a Return Material Authorization (RMA). Please include the following information: • • • •
Product model number Serial Number Complete description of problem Hardware installation description
Broadata Communications, Inc. 2545 West 237th Street, Suite K Torrance, CA 90505 1-800-214-0222 (310) 530-1416 (310) 530-5958 (Facsimile) e-mail:
[email protected] Website: www.broadatacom.com
26
Broadata Technical Support, (800) 214-0222
LBH-DVI-EAD User’s Manual Link Bridge TM HDBT DVI Video Converting Transmitter System
7.0 LIMITED WARRANTY Broadata Communications, Inc. (BCI) warrants, for a period of one year from date of shipment, each product sold shall be free from defects in material and workmanship. BCI will correct, either by repair, or at BCI’s election, by replacement, any said products that in our sole discretion prove to be defective and are returned to the manufacturing location within 30 days after such defect is ascertained. All warranties are limited to defects arising under normal use and do not include malfunctions or failure resulting from misuse, abuse, neglect, alterations, electrical power problems, usage not in accordance with product instructions, improper installation, or damage determined by BCI to have been caused by the Buyer or repair made by a third party. Limited warranties granted on products are to the initial customer end-user and are not transferable. OUR LIABILITY UNDER THIS WARRANTY SHALL IN ANY CASE BE LIMITED TO THE INVOICE VALUE OF THE PRODUCT SOLD AND BCI SHALL NOT BE LIABLE TO ANYONE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE USE OF ITS PRODUCTS OR THE SALE THEREOF. We make NO WARRANTY AS TO THE MERCHANTABILITY OF ANY GOODS, OR THAT THEY ARE FIT FOR ANY PARTICULAR PURPOSE OR END APPLICATION NOR DO WE MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OTHER THAN AS STATED ABOVE.
Broadata Technical Support,
[email protected]
27
LBH-DVI-EAD User’s Manual Link BridgeTM HDBT DVI Video ConvertingTransmitter System
28
Broadata Technical Support, (800) 214-0222
Broadata Communications, Inc. 2545 West 237th Street, Suite K Torrance, CA 90505 1-800-214-0222 (310) 530-1416 (310) 530-5958 (Facsimile) e-mail:
[email protected] Website: www.broadatacom.com
60000-LBHDVI-EAD-080714