Preview only show first 10 pages with watermark. For full document please download

Lc Power Supply Relay For La

   EMBED


Share

Transcript

Technical Information – Date 2010-07-21 LC Power Supply /1 Summary Subject to change without notice. We are not responsible for technical errors. DUO_N101ENG_LCPowerS1 • Power Supply for connection to a light grid of type LA/LT (with PNP-Output; transmitter without raised transmission capacity • Input voltage 230 Vac • Plastic housing, IP65, cable feed-through with PG-fitting • Floating relay contacts for switching signal DUOmetric AG Weberstr. 8 86836 Lagerlechfeld / Germany Tel: +49-8232-95979-0 Fax: +49-8232-95979-29 www.duometric.de Email: [email protected] Technical Information LCPower/1 Connectivity Concept Connection of Light Grids: Grids: Type LT LA Output Core Function Description Out 1 Black Light switching active with uninterrupted monitoring range Out 2 Yellow Dark switching active with interrupted monitoring range Out 1 Yellow Warning Output Out 2 Black Signal Output active during malfunction Light or dark switching Circuit board view Power Input LED: Relay, green Relays Output Page 2 of 4 Technical Information LCPower/1 Function Function Relay Relays The relay is active when pin 11 is high. Example light grid: Beams disrupted Free monitoring range Light switching disengaged engaged Dark switching engaged disengaged Housing View PG9 Fitting PG7 Fitting Page 3 of 4 Technical Information LCPower/1 Startup Instructions • • • • • • • Follow proper start-up procedures. For housing installation use only dedicated mounting holes. Do not drill any additional holes into the housing as it will terminate your warranty! Wires are clamped by spring terminals. Use only appropriate wire gauges. Connect power wires at the very end. Output Supply voltage to light grids (Plus 24Vdc:Pin 4,5; Minus: 8,9) is not shortcircuit proof. Thoroughly tighten PG-fittings. Thoroughly mount housing cover. Technical Technical Data Protection class (DIN 40050) Connections Supply voltage Power consumption Outputs Dimensions Cable feed-through Temperature range (ambient) IP 65 For one transmitter & receiver set (plus switching) Spring terminals for wire core diameters of 2 0,2…1,5 mm 230 Vac (±10%), 50…60 Hz ~ 8 VA Up to 250 V, 5 A, 1100 VA 160 mm x 80 mm x 55 mm (L x W x H) 2x PG7-fitting for connecting light grid 2x PG9-fitting for power, relays output, etc. Cable core diameter 4.5…7 mm -10…40 °C Adhere to installation instructions and technical information for the light grid profiles. Export information: This product must only be exported to the USA with the explicit permission of the manufacturer. Page 4 of 4