Transcript
VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET
LC-R067R2P
For main and standby power supplies. Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C.
Dimensions (mm)
0.28 (7)
0.28 (7)
Photo/Label for reference only.
0.01 (0.3)
4.016 ± 0.059 (101.7 ± 1.5)
2.756 ± 0.039 (70 ± 1)
1.890 ± 0.039 (48 ± 1)
0.24 (6)
0.02 (0.5)
Terminal type: Faston 187 or Faston 250
2.724 (69.2)
1.87 (47.4)
Specifications
Dimensions
6V 7.2Ah 5.945 inches (151.0 mm)
Width
1.339 inches (34.0 mm)
Height
3.702 inches (94.0 mm)
Total Height*
3.937 inches (100.0 mm)
Approx. mass Standard Terminals and Resin Optional Terminals and Resin
2.78 lbs. (1.26 kg)
UL94HB Faston 187
LC-R067R2P
UL94HB Faston 250
LC-R067R2P1
UL94HB Faston 187/250
LC-R067R2P2
Battery case resin: Standard (UL94HB) Color is black.
Discharge characteristics 77°F (25°C) (Note) Terminal voltage (V)
Nominal Voltage Rated Capacity (20 hour rate) Length
7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5
♦ Please contact Panasonic for availability on optional items. Optional items may be subject to
2.88A 1.44A 11.52A 23.04A
0 1
minimum order quantities.
0.72A 0.36A
5.76A
2
4
6 8 10
20
40 60
2
4
(Minute)
6 8 10
20
40
(Hour)
Discharge time
Characteristics
Self discharge 77˚F (25˚C)
Charge Method (Constant Voltage)
Cycle use (Repeating use)
20 15
3.5A
10
Approx. 20mΩ 102% 100% 85% 65% 91% 82% 64%
(Hour)
Temperature dependency of capacity (20 hour rate)
104˚F (40˚C) 5 4 3 2 1.5
77˚F (25˚C) 32˚F (0˚C)
5˚F (-15˚C) 1 50 40 30 20
Initial current
2.88 A or smaller
Control voltage
7.25V to 7.45V (per 6V cell 25˚C)
Initial current
1.08 A or smaller
5
Control voltage
6.8V to 6.9V (per 6V cell 25˚C)
3 100
Trickle use
(Note)
30
Duration of discharge
Internal Resistance
7.2Ah 6.8Ah 6.3Ah 4.9Ah
(Minute)
Capacity (note) 77˚F (25˚C)
Duration of discharge vs. Discharge current 20 hour rate (3650mA) 10 hour rate (680mA) 5 hour rate (1260mA) 1 hour rate (4900mA) 1.5 hour rate discharge Cut-off voltage 5.25 V Fully charged battery 77˚F (25˚C) 104˚F (40˚C) 77˚F (25˚C) 32˚F (0˚C) 5˚F (-15˚C) Residual capacity after standing 3 months Residual capacity after standing 6 months Residual capacity after standing 12 months
(Note) The above characteristics data are average values obtained within three charge/discharge. Cycles not the minimum values.
VRLA BATTERIES
10
300 500
1
3
5
(mA)
10
30
50
(A) Discharge current
AUGUST 2003
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information.