Preview only show first 10 pages with watermark. For full document please download

Lcf12-50j-p7 - Radio Frequency Systems

   EMBED


Share

Transcript

PRODUCT DATASHEET LCF12-50J-P7 1/2" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable CELLFLEX® 1/2" low loss flexible cable FEATURES / BENEFITS Low Attenuation The low attenuation of CELLFLEX® coaxial cable results in highly efficient signal transferin your RF system. Complete Shielding The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference. Low VSWR Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise. Outstanding Intermodulation Performance CELLFLEX®FRD[LDOFDEOHVVROLGLQQHUDQGRXWHUFRQGXFWRUVYLUWXDOO\HOLPLQDWHLQWHUPRGV Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory. High Power Rating Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels. Wide Range of Application Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects. 1/2" CELLFLEX® Low-Loss Foam Dielectric Coaxial Cable Technical Features APPLICATIONS Applications OEM jumpers, Main feed transitions to equipment, GPS lines, intended for outdoor usage STRUCTURE Cable Type Size Jacket Option Inner Conductor Dielectric Outer Conductor Jacket mm (in) mm (in) mm (in) mm (in) Foam-Dielectric, Corrugated 1/2" Black 4.8 (0.19) Copper-Clad Aluminum Wire 11.9 (0.47) Foam Polyethylene 13.8 (0.54) Corrugated Copper 15.8 (0.62) Polyethylene, PE ELECTRICAL SPECIFICATIONS ȍ GHz % pF/m (pF/ft) µH/m (µH/ft) kW Volts Volt RMS ȍm ȍft) ȍm ȍft) Impedance Maximum Frequency Velocity Capacitance Inductance Peak Power Rating RF Peak Voltage Jacket Spark Inner Conductor dc Resistance Outer Conductor dc Resistance Return Loss (VSWR) Performance Maximum Return Loss Phase Stabilized Temperature & Power dB (VSWR) 50 +/- 1 8.8 88.0 76 (23.2) 0.19 (0.058) 38.0 1950.0 8000.0 1.57 (0.48) 2.7 (0.82) Premium for 698 - 794, 824 - 960, 1710 - 1755, 1850 - 1990, 2110 - 2155 MHz 24 (1.135) Phase stabilized and phase matched cables and assemblies are available upon request. Standard MECHANICAL SPECIFICATIONS Cable Weight Minimum Bending Radius Minimum Bending Radius Bending Moment Tensile Strength Recommended / Maximum Clamp Spacing LCF12-50J-P7 REV: E kg/m (lb/ft) mm (in) mm (in) Nm (lb*ft) N (lb) m (ft) 0.2 (0.14) 70 (3) 125 (5) 6.5 1100 (247) 0.6 / 1 (2 / 3.25) REV DATE: 26.Jun.2017 All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering www.rfsworld.com Page 1 of 2 PRODUCT DATASHEET LCF12-50J-P7 1/2" CELLFLEX® Low-Loss Foam-Dielectric Coaxial Cable ATTENUATION AND POWER RATING Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 750 800 824 894 900 925 960 1000 1250 1400 1500 1700 1800 2000 2100 2200 2400 2500 2600 2700 3000 3500 4000 5000 6000 7000 8000 8800 Attenuation dB/100m dB/100ft 0.15 0.045 0.21 0.064 0.26 0.079 0.30 0.091 0.67 0.204 0.95 0.29 1.17 0.356 1.51 0.462 2.02 0.616 2.16 0.658 2.24 0.684 2.66 0.81 2.87 0.875 3.08 0.94 3.81 1.16 4.43 1.35 4.71 1.44 4.98 1.52 5.04 1.54 5.48 1.67 5.95 1.81 6.17 1.88 6.39 1.95 6.49 1.98 6.78 2.07 6.80 2.07 6.90 2.10 7.04 2.15 7.20 2.19 8.12 2.48 8.64 2.63 8.97 2.73 9.61 2.93 9.91 3.02 10.50 3.20 10.80 3.29 11.10 3.38 11.60 3.54 11.90 3.62 12.20 3.70 12.40 3.78 13.20 4.01 14.40 4.38 15.50 4.72 17.60 5.37 19.60 5.97 21.40 6.54 23.20 7.07 24.60 7.49 Power kW 38.00 38.00 32.90 28.50 12.70 8.93 7.26 5.63 4.21 3.93 3.79 3.19 2.96 2.76 2.23 1.92 1.80 1.71 1.69 1.55 1.43 1.38 1.33 1.31 1.25 1.25 1.23 1.21 1.18 1.05 0.983 0.947 0.884 0.857 0.809 0.787 0.765 0.732 0.714 0.696 0.685 0.644 0.59 0.548 0.483 0.433 0.397 0.366 0.345 TESTING AND ENVIRONMENTAL Fire Performance Installation Temperature Storage Temperature Operation Temperature Halogene Free -40 to 60 (-40 to 140) °C(°F) -70 to 85 (-94 to 185) °C(°F) -50 to 85 (-58 to 185) °C(°F) PREMIUM PERFORMANCE CODES Properties no suffix Specify when ordering 24.0 dB 1.135:1 6.30% P1 410-470 MHz 23.0 dB 1.152:1 7.10% P2 790-960 MHz 24.0 dB 1.135:1 6.30% P3 2500-2700 MHz 24.0 dB 1.135:1 6.30% P4 1700-1880 MHz 24.0 dB 1.135:1 6.30% P5 1710-2155 MHz 28.0 dB 1.083:1 4.00% P6 1900-2200 MHz 24.0 dB 1.135:1 6.30% P7 698-794, 824-960, 1710-1755, 1850-1990 and 2110-2155 MHz 790-960 MHz and 1710-2200 MHz 24.0 dB 1.135:1 6.30% 23.0 dB 1.152:1 7.10% P8 Attenuation at 20°C (68°F) cable temperature; tolerance +/- 5% max.; Mean power rating at 40°C (104°F) ambient temperature External Document Links Notes Phase stabilized versions available upon request. LCF12-50J-P7 REV: E REV DATE: 26.Jun.2017 All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering www.rfsworld.com Page 2 of 2