Preview only show first 10 pages with watermark. For full document please download

Ld1500 Catalog Page

   EMBED


Share

Transcript

NEW! LEVEL & leak detection Leak Detector LD1500 DESCRIPTION The RLE Technologies LD1500 leak detector offers a reliable leak detection solution that mitigates potential water damage, costly business outages, and downtime. The unit detects the presence of any conductive fluid and identifies the distance to the leak. The distance to the leak can be communicated via various protocols to alarm monitoring and notification systems. The physical location of the leak can be determined by cross-referencing the distance with a cable reference map of your site. LD1500 Sensing cable is available in standard lengths with preinstalled mating end connectors. Linked end-to-end these connections allow for easy installation of additional length. The LD1500 can monitor up to 1500 ft (457m) of sensing cable or 1050 ft (320m) or chemical sensing cable. WIRING FEATURES • Adjustable leak, delay and cable contamination alarm thresholds • SNMP, Modbus and BACnet communications • Quick return to normal status after cable is wiped dry • Modbus (RS-485) integration with LD2100 and LD5100 • HTML interface • Self calibrating End Terminator Leader Cable Sensing Cable 10 Basic installation of LD1500,leader cable, sensing cable and EOL terminator Specifications Repeatability Communication Ports Ethernet RS-232 RS-485 RJ-45 Protocol Terminal Emulation (RS-232) SNMP Modbus (RS-485/IP) 24 VAC/VDC @ 600 mA max 1A @ 24 VDC, 0.5A resisitive @ 120 VAC ±2 ft (0.6m) plus ±0.5% of the cable length ±2 ft (0.6m) plus ±0.25% of the cable length 10/100 BASE-T, 500 VAC RMS isolation 9600 baud, no parity, 9 data bits, 1 stop bit 1200, 2400, 9600 or 19200 baud (selectable), no parity, 8 data bits, 1 stop bit 10/100BASE-T Ethernet Port VT100 compatible V1: V2C MIB-2 compliant; NMS Manageable with Get, Set, Traps Slave, RTU mode; supports function codes 03, 04, 06, and 16 BACnet (MS/TP & IP) LED Indication Response Time Alarm Logging Samples Security Login Operating Humidity Operating Temperature Mounting Cable Length Cable Type Dimensions Approvals Weight Warranty EIA-485 1 bi-color power/status (green=power on, red=alarm) Adjustable from 5-995 seconds Bi-color status LED Logging capabilities: Logs last 10 events Web browser access: 1 Web password read only, 1 password read/write 5 to 95% non-condensing 32° to 122°F (°0 to 50°C) Wall mount 1500 ft (457.2m) maximum Water detection cable 3.6"H x 7.0"W x 1.25"D (9.2 x 17.8.0 x 3.2 cm) CE, ETL Listed, RoHS compliant 1.5 lb (0.68 kg) 1 year LEVEL & LEAK DETECTION Supply Voltage Relay Outputs Accuracy ORDERING INFORMATION MODEL DESCRIPTION LD1500 Water detector includes 15' leader cable and end-of-line connector (order sensing cable separately) JC-200 JC-25 NSC-10 NSC-100 NSC-25 NSC-50 SC-10 March 2014 RELATED PRODUCTS PAGE Package of 200 cable-securing J clips Package of 25 cable-securing J clips 10' non-sensing cable 100' non-sensing cable 25' non-sensing cable 50' non-sensing cable 10' sensing cable 581 SC-100 SC-25 SC-50 WCCS-50 X-CON RELATED PRODUCTS 100' sensing cable 25' sensing cable 50' sensing cable Weighted cable connector; simulates 50' of sensing cable X connector single SC input, 3 SC outputs WE MAKE IT EASY. kele.com PAGE 581 581 581 888-397-5353 USA 575