Preview only show first 10 pages with watermark. For full document please download

Le Relays (ale) Le (ale) Features 1a 16a Power Relay For

   EMBED


Share

Transcript

LE (ALE) VDE 1a 16A power relay for micro wave oven LE RELAYS (ALE) FEATURES TMP type PCB type 1. Supports magnetron and heater loads. Capable for switching magnetron and heater loads found in microwave ovens. 2. Excellent heat resistance Ambient temperature: up to 85C 185F Certified UL coil insulation class B and class F 3. High insulation resistance Creepage distance and clearances between contact and coil: Min. 8 mm .315 inch Surge withstand voltage: 10,000V 4. Low operating power Nominal operating power: 400mW/ 200mW (High sensitive type) 5. A wide variety of types Product line consists of 4 types with different shapes and pins 6. Conforms to the various safety standards: UL, CSA, TÜV and VDE approved UL, CSA and VDE approved (PCB type) TYPICAL APPLICATIONS • Microwave ovens • Refrigerators • OA equipment ORDERING INFORMATION ALE LE relay Contact arrangement 1: 1 Form A (400 mW) 7: 1 Form A (200 mW) Terminal shape 2: TMP type/PCB side three terminals (includes one dummy terminal) 3: TMP type/PCB side three terminals 4: TMP type/PCB side four terminals P: PCB type (No tab terminals) Coil insulation class B: Class B insulation F: Class F insulation Nominal coil voltage, V DC 05: 5, 06: 6, 09: 9, 12: 12, 18: 18, 24: 24, 48: 48 Notes: • Certified by UL, CSA, TÜV and VDE (TMP type). • Certified by UL, CSA and VDE (PCB type). ds_61B11_en_le: 290212J 1 LE (ALE) TYPES 1. Standard type TMP type Contact arrangement Nominal coil voltage 1 Form A 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC PCB side three terminals (includes one dummy terminal) Part No. ALE12❍05 ALE12❍06 ALE12❍09 ALE12❍12 ALE12❍18 ALE12❍24 ALE12❍48 PCB side three terminals PCB side four terminals PCB type (No tab terminals) Part No. ALE13❍05 ALE13❍06 ALE13❍09 ALE13❍12 ALE13❍18 ALE13❍24 ALE13❍48 Part No. ALE14❍05 ALE14❍06 ALE14❍09 ALE14❍12 ALE14❍18 ALE14❍24 ALE14❍48 Part No. ALE1P❍05 ALE1P❍06 ALE1P❍09 ALE1P❍12 ALE1P❍18 ALE1P❍24 ALE1P❍48 PCB side three terminals PCB side four terminals PCB type (No tab terminals) Part No. ALE73❍05 ALE73❍06 Part No. ALE74❍05 Part No. ALE7P❍05 ALE74❍06 ALE74❍09 ALE74❍12 ALE74❍18 ALE74❍24 ALE74❍48 ALE7P❍06 ALE7P❍09 ALE7P❍12 ALE7P❍18 ALE7P❍24 ALE7P❍48 ❍: Input the following letter. Class B: B, Class F: F Note: Standard packing; Carton: 100 pcs. Case 500 pcs. 2. High sensitive type TMP type Contact arrangement Nominal coil voltage 1 Form A (High sensitivity: 200mW) 5V DC 6V DC PCB side three terminals (includes one dummy terminal) Part No. ALE72❍05 ALE72❍06 9V DC 12V DC 18V DC 24V DC 48V DC ALE72❍09 ALE72❍12 ALE72❍18 ALE72❍24 ALE72❍48 ALE73❍09 ALE73❍12 ALE73❍18 ALE73❍24 ALE73❍48 ❍: Input the following letter. Class B: B, Class F: F Note: Standard packing; Carton: 100 pcs. Case 500 pcs. RATING 1. Coil data 1) Standard type Nominal coil voltage Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 75%V or less of nominal voltage (Initial) 5%V or more of nominal voltage (Initial) Nominal operating current [10%] (at 20C 68F) 80 mA 66.7mA 44.4mA 33.3mA 22.2mA 16.7mA 8.3mA Nominal operating power (at 20C 68F) Max. applied voltage (at 20C 68F) 63 90 203 360 810 1,440 5,760 400mW 7.25V DC 8.7 V DC 13.05V DC 17.4 V DC 26.1 V DC 34.8 V DC 69.6 V DC Nominal operating power (at 20C 68F) Max. applied voltage (at 20C 68F) 200mW 7.25V DC 8.7 V DC 13.05V DC 17.4 V DC 26.1 V DC 34.8 V DC 69.6 V DC Coil resistance [10%] (at 20C 68F) 2) High sensitive type Nominal coil voltage 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 2 Pick-up voltage (at 20C 68F) 75%V or less of nominal voltage (Initial) Drop-out voltage (at 20C 68F) Nominal operating current [10%] (at 20C 68F) Coil resistance [10%] (at 20C 68F) 5%V or more of nominal voltage (Initial) 40 mA 33.3mA 22.2mA 16.7mA 11.1mA 8.3mA 4.2mA 125 180 405 720 1,620 2,880 11,520 ds_61B11_en_le: 290212J LE (ALE) 2. Specifications Characteristics Contact Rating Item Contact material Arrangement Contact resistance (Initial) Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (reference value)*1 Insulation resistance (Initial) Breakdown voltage (Initial) Electrical characteristics Specifications AgSnO2 type 1 Form A Max. 100 m (By voltage drop 6 V DC 1A) 16A 277V AC 4,432VA 277V AC 16A 400mW (Standard type), 200mW (High sensitive type) 100mA, 5V DC Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section. Between open contacts Between contact and coil 1,000 Vrms for 1 min. (Detection current: 10 mA) 4,000 Vrms for 1 min. (Detection current: 10 mA) Max. 55C 131F, Max. 45C 113F (200mW type) (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 16A, at 20C 68F) Temperature rise (coil) Surge breakdown voltage*2 (Between contact and coil) (Initial) Operate time (at nominal voltage) (at 20C 68F) Release time (at nominal voltage) (at 20C 68F) Functional Destructive Functional Vibration resistance Destructive Mechanical (at 180 times/min.) Electrical (at 20 times/min.) Shock resistance Mechanical characteristics Expected life Conditions for operation, transport and storage*3 Conditions Max. operating speed Unit weight 10,000 V Max. 20 ms (excluding contact bounce time.) Max. 20 ms, Max. 25 ms (200mW type) (excluding contact bounce time) (With diode) 200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.) 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.) 10 to 55 Hz at double amplitude of 1.5 mm Min. 2106 Min. 105 (at resistive load) Ambient temperature: –40C to +85C –40F to +185F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Approx. 17 g .60 oz, Approx. 15 g .53 oz (PCB type) * Specifications will vary with foreign standards certification ratings. Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information. REFERENCE DATA 1-1. Coil temperature rise (400mW type) 1-2. Coil temperature rise (200mW type) Sample: ALE14B12, 6 pcs. Point measured: coil inside Ambient temperature: 25C 77F, 85C 185F Sample: ALE74B12, 6 pcs. Point measured: coil inside Ambient temperature: 23.7C 74.66F, 85C 185F 12A 0A 40 30 20 10 0 23.7°C 85°C 100 16A 25 16A 0A Temperature rise, °C 16A 12A 0A 16A 50 Temperature rise, °C 30 25°C 85°C 250V AC resistive load 20 0A 15 Life, x104 60 2. Life curve 10 10 5 0 80 100 Coil applied voltage, %V ds_61B11_en_le: 290212J 145 0 0 80 100 Coil applied voltage, %V 145 1 0 2 4 6 8 10 12 14 16 Contact current, A 3 LE (ALE) 3. Electrical life test (16 A 277 V AC, resistive load) Sample: ALE14B12, 6 pcs. Operation frequency: 20 times/min. (ON/OFF = 1.5s: 1.5s) Ambient temperature: Room temperature Circuit: Pick-up and drop-out voltage, %V COM 70 NO 277V AC 60Hz 12V DC G Pick-up voltage 60 Max. x Min. 50 40 30 Drop-out voltage 20 Max. x Min. 10 0 0 10 No. of operations, x104 DIMENSIONS (mm inch) CAD Data Data from our Web site. Download CAD 1. TMP type PCB side three terminals (includes one dummy terminal) External dimensions CAD Data #187 terminal 6.0 .236 PC board pattern (Bottom view) 2-1.3 dia. .051 dia. 4.75 .187 0.5 .020 6.35 .250 8.5 .335 1.8 dia. .071 dia. 7.5 .295 26.0 1.024 24.9 .980 Tolerance: 0.1 .004 Schematic (Bottom view) Com 3.5 .138 1.8 .071 0.4 .016 26.0 1.024 28.6 1.126 0.8 .031 0.8 2.45 .031 .096 7.5 .295 12.4 .488 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 4 No 1.5 .059 0.8 .031 Tolerance 0.1 .004 Coil 0.2 .008 0.3 .012 ds_61B11_en_le: 290212J LE (ALE) PCB side three terminals External dimensions CAD Data 6.0 .236 #187 terminal PC board pattern (Bottom view) 3-1.3 dia. .051 dia. 4.75 .187 0.5 .020 6.35 .250 8.5 .335 7.5 .295 23.5 .925 24.9 .980 Tolerance: 0.1 .004 Schematic (Bottom view) 3.5 .138 1.8 .071 0.4 .016 0.5 .020 23.5 .925 28.6 1.126 1.0 .039 2.45 .096 Com 7.5 .295 12.4 .488 No 0.8 .031 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: Tolerance 0.1 .004 Coil 0.2 .008 0.3 .012 PCB side four terminals External dimensions CAD Data #187 terminal 6.0 .236 PC board pattern (Bottom view) 4-1.3 dia. .051 dia. 4.75 .187 0.5 .020 6.35 .250 8.5 .335 7.5 .295 20.0 .787 24.9 .980 3.5 .138 Tolerance: 0.1 .004 Schematic (Bottom view) 3.5 .138 1.8 .071 0.8 .031 0.8 .031 ds_61B11_en_le: 290212J 0.4 .016 0.5 .020 20.0 .787 28.6 1.126 3.5 .138 1.0 .039 2.45 .096 1.0 .039 Com 7.5 .295 12.4 .488 Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: No Tolerance 0.1 .004 Coil 0.2 .008 0.3 .012 5 LE (ALE) 2. PCB type (No tab terminals) External dimensions PC board pattern (Bottom view) CAD Data 4-1.3 dia. 4-.051 dia. 7.5 .295 24.9 .980 20.0 .787 4.3 .169 3.5 .138 Tolerance: 0.1 .004 0.4 .016 1.8 .071 0.8 .031 0.3 .012 0.5 .020 3.5 .138 20.0 .787 28.6 1.126 1.0 .039 2.45 .096 1.0 .039 Schematic (Bottom view) 7.5 .295 12.4 .488 Coil Dimension: Less than 1mm .039inch: Min. 1mm .039inch less than 3mm .118 inch: Min. 3mm .118 inch: 0.8 .031 Tolerance 0.1 .004 No Com 0.2 .008 0.3 .012 SAFETY STANDARDS UL/C-UL (Recognized) File No. Contact rating E43149 16A 277V AC 16A 30V DC 18A 125V AC CSA (Certified) File No. Contact rating LR26550 16A 277V AC 16A 30V DC 18A 125V AC File No. 40009159 VDE (Certified) Contact rating 16A 250V AC (cos=1.0) 16A 30V DC (0ms) TV rating (UL/CSA) File No. Rating UL E43149 CSA LR26550 TV-5 File No. TÜV (Certified) Rating B 11 05 16A 250V AC (cos=1.0) 13461 297 16A 30V DC (0ms) For Cautions for Use, see Relay Technical Information. 6 ds_61B11_en_le: 290212J