Serial ATA Test QPHY-SATA-TSG-RSG
Key Features • QPHY-SATA-TSG-RSG supports all PHY, TSG, OOB and RSG
QPHY-SATA-TSG-RSG is an
engineers to quickly find the root
automated test package for Serial
cause of serial data problems.
compliance tests as described
ATA compliance testing. It provides
by the Serial ATA Unified Test
connection diagrams to ensure
Document Version 1.4
the proper setup for the required
• Complete automation of physical layer transmitter and receiver testing • QPHY-SATA-TSG-RSG provides full reporting capability including Pass/Fail indications and screen-shots from pertinent tests • Eye Doctor™ II Advanced Signal Integrity Tools enable channel emulation and equalization which aids in debugging Serial ATA compliance failures • SDA II allows fast eye diagram creation and jitter analysis on long memory acquisitions
measurements, automates the oscilloscope for performing these measurements, and provides a comprehensive report of results including screenshots.
SDA II allows the user to quickly create eye diagrams utilizing the full record length of the oscilloscope and perform jitter analysis accurately using both the spectral and NQ-Scale methods of jitter decomposition. This is critically important for properly distinguishing between random and
By utilizing the PeRT3™, QPHY-
deterministic jitter in systems where
SATA-TSG-RSG can perform all of
there could be crosstalk present.
the PHY, TSG, OOB and RSG tests automatically. Using a single piece of equipment, the PeRT3 can replace the Arbitrary Waveform Generator and the Frame Error Rate tester that are typically used for SATA compliance testing. This reduces the investment and makes the test setup much simpler. The LeCroy SDA 8 Zi/Zi-A Series of oscilloscopes with the Eye Doctor™ II analysis package are the perfect instruments for performing Serial ATA compliance measurements and more importantly for debugging compliance failures allowing the
Additionally, Eye Doctor II provides the channel emulation and de-embedding tools that engineers need for next generation serial data standards. QPHY-SATA-TSG-RSG uses all of these oscilloscope features to perform the compliance tests as described by the SATA Unified Test Document.
complete transmitter and receiver testing The LeCroy QPHY-SATA-TSG-RSG automated test solution is the only solution that fully integrates transmitter and receiver testing into one test suite. Using the LeCroy Protocol-enabled Receiver and Transmitter Tolerance Tester (PeRT3), QPHY-SATA-TSG-RSG has the ability to perform all of the 1.5 Gb/s, 3.0 Gb/s and 6.0 Gb/s SATA receiver tests as described by the SATA Unified Test Document. Also, the PeRT3 can connect to the device under test, set the device to output the proper test pattern or enter loopback mode and output the proper test pattern. Then QPHY-SATA-TSG-RSG uses the SDA
Spread Spectrum Clock (SSC) validation requires long memory and specialized analysis functions. LeCroy is the only manufacturer that can precisely track SSC profiles through multiple cycles in real time.
813Zi/Zi-A oscilloscope to perform all of the SATA transmitter measurements as described by the Unified Test Document. All of this can be done simply with the push of a button. Using the TF-SATA-C, the transmitter output of the product under test can be connected between either the PeRT3 input or the oscilloscope input. Additionally, the transmitter output of the PeRT3 can be connected between either the product under test or the oscilloscope which is used for automatic calibration of the jitter output. The ISI channel for 1.5 Gb/s, 3.0 Gb/s or
OOB timing measures COMINIT/COMRESET and COMWAKE bit rate, burst and gap widths.
6.0 Gb/s, which is required for receiver testing, can be put in the path from the PeRT3 to the product under test. Additionally, since all of these tests are run from QPHY-SATA-TSG-RSG, the results of the transmitter test as well as the receiver results can be created in one comprehensive report. Finally, everything required for SATA testing can be ordered with LeCroy’s SATA Bundles. For additional information on LeCroy’s SATA Bundle Options please visit www.lecroy.com.
2
Clock-to-data Jitter Measurements. Clock recovery options enable you to meet the Jitter Transfer Function (JTF) specification requirements. Industry-leading Q-Scale analysis provides the industry’s most precise breakdown of Random and Deterministic Jitter (Rj and Dj).
SGRSG -Bu ndl e
le
SAT A-T
Transmitter Test
SAT A-R SGBun d
Product Code
SAT A-T
Product Description
SGBun d
le
sata test suites
SDA 813Zi-A Oscilloscope 13 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch Serial Data Analyzer with 15.3" WXGA Color Display. 50 Ω and 1 MΩ Input Eye Doctor Advanced Signal Integrity Tools for WaveMaster® 8 Zi/Zi-A Oscilloscopes QualiPHY Enabled SATA Software Option SATA 1.5 Gb/s, 3.0 Gb/s and 6.0 Gb/s Compliance Test Fixture
SDA 813Zi/Zi-A
3
3
WM8Zi-EYEDRII
3
3
QPHY-SATA-TSG-RSG
3
TF -SATA-C
3
3 3
3
3
3
Receiver Test PeRT3 Hardware Platform Eagle PeRT3 System – 1 Channel
PER-R006-S01-X
Eagle PeRT3 System – 2 Channel
PER-R006-S02-X
Eagle PeRT3 System – 4 Channel
3
PER-R006-S04-X
Eagle Test Suite Options Eagle Receiver Tolerance Test Suite
PER-R006-008-A
3
3
Eagle SATA Receiver Test Suite
SAT-R006-004-A
3
3
Accessories Keithley S46 RF-Microwave Switch System with 8 SPDT relays installed
RF-Switch-8-SPDT
3
GPIB-Host
3
Pair of ±1 ps Matched SMA-SMA Cables 8 Inches (3 pair are included)
Matched-SMA-Cables-8inch-Pair
3
Pair of ±1 ps Matched SMA-SMA Cables 12 Inches (2 pair are included)
Matched-SMA-Cables-12inch-Pair
3
Pair of ±1 ps Matched SMA-SMA Cables 18 Inches (2 pair are included)
Matched-SMA-Cables-18inch-Pair
3
Pair of ±1 ps Matched SMA-SMA Cables 24 Inches
Matched-SMA-Cables-24inch-Pair
GPIB Host Option for LeCroy Oscilloscope
3
3
Eagle SATA Switch (includes 2 pair of SMA-SMA cables)
PER-AC06-001-X
3
3
SATA ISI Channel (includes 2 pair of SMA-SMA cables)
PER-AC06-P01-X
3
3
Low-Pass Rise Time Filter 100 ps (2 filters included)
Rise-Time-Filter-100ps
3
3
Low-Pass Rise Time Filter 150 ps (2 filters included)
Rise-Time-Filter-150ps
3
3
20 dB Attenuator (2 attenuators included)
20dB-SMA-Attenuator
3
SATA-TSG-Bundle can be used to perform PHY and TSG tests only. A BIST initiator is also required. SATA-RSG-Bundle can be used to perform RSG test only. SATA-TSG-RSG-Bundle can be used to perform PHY, TSG, OOB and RSG tests.
3
specifications and ordering information QPHY-SATA-TSG-RSG Test Coverage
Ordering Information
Phy General Requirements
Product Description QualiPHY Enabled SATA Software Option
Test PHY-01 – Unit Interval Test PHY-02 – Frequency Long Term Accuracy
Product Code QPHY-SATA-TSG-RSG
13 GHz 40 GS/, 4 Ch, 20 Mpts/Ch Serial Data Analyzer with 15.3" WXGA Color Display, 50 Ω and 1 MΩ Input
Test PHY-03 – SSC Frequency Test PHY-04 – SSC Deviation
SDA 813Zi/Zi-A
Eye Doctor Advanced Signal Integrity Tools For WaveMaster 8 Zi-A Oscilloscopes
Phy Transmitter Signal Requirements Test TSG-01 – Differential Output Voltage
WM8Zi-EYEDRII
Eagle PeRT 3 System – 1 Channel
PER-R006-S01-X
Eagle Receiver Tolerance Test Suite
PER-R006-008-A
Test TSG-03 – Differential Skew
Eagle SATA Receiver Test Suite
SAT-R006-004-A
Test TSG-04 – AC Common Mode Voltage
SATA 1.5 Gb/s, 3.0 Gb/s and 6.0 Gb/s Compliance Test Fixture
Test TSG-02 – Rise/Fall Time
Test TSG-05 – Rise/Fall Imbalance
TF-SATA-C
SATA 1.5 Gb/s, 3.0 Gb/s and 6.0 Gb/s Compliance Test Fixture Measure Kit
Test TSG-06 – Amplitude Imbalance Test TSG-09 – Gen1 TJ at Connector, fBAUD/500 Test TSG-10 – Gen1 DJ at Connector, fBAUD/500
TF-SATA-C-KIT
SATA Bundles SATA PHY, TSG and OOB Test Bundle
SATA-TSG-Bundle
Test TSG-11 – Gen2 TJ at Connector, fBAUD/500
SATA RSG Test Bundle
SATA-RSG-Bundle
Test TSG-12 – Gen2 DJ at Connector, fBAUD/500
SATA PHY, TSG, OOB and RSG Test Bundle
Test TSG-13 – Gen3 Transmit Jitter
Compatible Oscilloscopes
Test TSG-14 – Gen3 TX Maximum Differential Voltage
WavePro®/SDA/DDA 760 Zi or higher bandwidth*† (1.5 Gb/s testing only)
Test TSG-15 – Gen3 TX Minimum Differential Voltage
WaveMaster®/SDA/DDA 813 Zi/Zi-A or higher bandwidth*†
Test TSG-16 – Gen3 TX AC Common Mode Voltage
SDA 13000*†
SATA-TSG-RSG-Bundle
*SDA II is required for QPHY-SATA-TSG-RSG. † Eye Doctor II is required for QPHY-SATA-TSG-RSG.
Phy OOB Requirements Test OOB-01 – OOB Signal Detection Threshold Test OOB-02 – UI During OOB Test OOB-03 – COMINIT and COMWAKE Burst Length Test OOB-04 – COMINIT Transmit Gap Length Test OOB-05 – COMWAKE Transmit Gap Length Test OOB-06 – COMWAKE Gap Detection Windows Test OOB-07 – COMINIT Gap Detection Windows Phy Receive Signal Requirements RSG-01 : Gen1 (1.5 Gb/s) Receiver Jitter Tolerance Test RSG-02 : Gen2 (3 Gb/s) Receiver Jitter Tolerance Test RSG-03 : Gen3 (6 Gb/s) Receiver Jitter Tolerance Test RSG-05 : Receiver Stress Test at +350ppm RSG-06 : Receiver Stress Test With SSC
LeCroy TF-SATA-C can be used for 1.5 Gb/s, 3.0 Gb/s and 6.0 Gb/s SATA compliance testing.
Customer Service LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes: • No charge for return shipping • Long-term 7-year support • Upgrade to latest software at no charge
1-800-5-LeCroy www.lecroy.com
Local sales offices are located throughout the world. Visit our website to find the most convenient location.
© 2010 by LeCroy Corporation. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders.