Preview only show first 10 pages with watermark. For full document please download

Led Rolling Scan   Led rolling scan (ea ‐ 3020) manual  2009‐08‐01 

   EMBED


Share

Transcript

  LED ROLLING SCAN             LED ROLLING SCAN (EA ‐ 3020) Manual    2009‐08‐01    INCLUDED IN BOX:   1 x EA ‐ 3020   USER MANUAL    UNPACKING INSTRUCTIONS  UPON RECEIVING THE UNIT, UNPACK CARTON AND VERIFY THAT ALL PARTS HAVE BEEN RECEIVED IN  GOOD CONDITION.  IF THERE IS ANY SIGN OF DAMAGE TO THE CARTON OR UNIT DUE TO SHIPPING OR  MISHANDLING, NOTIFY THE SHIPPER IMMEDIATELY. KEEP ORIGINAL PACKING MATERIALS IN THE  EVENT THE UNIT MUST BE RETURNED FOR ANY REASON. ALL FIXTURES MUST BE RETURNED IN THEIR  ORIGINAL PACKAGING.  IF ANY ACCESSORY IS MISSING THAT SHOULD HAVE BEEN RECEIVED WITH THE UNIT, NOTIFY  OMNISISTEM IMMEDIATELY WITHIN 3 DAYS OF RECEIVING THE ITEM. IF NOTIFICATION IS NOT  RECEIVED WITHIN 3 DAYS, UNIT IS CONSIDERED TO HAVE BEEN RECEIVED WITH ALL COMPONENTS  AND WITHOUT DAMAGES.   CONTACT US  OFFICE:                                                           TECHNICAL SUPPORT:                                                               VISIT US ON THE WEB:  OMNISISTEM LIGHTS & EFFECTS  6403 SOUTH 208th STREET  KENT, WA 98032  TEL:  253‐395‐9500  FAX:   253‐395‐9494  HOURS OF OPERATION:  MONDAY – FRIDAY 8AM ‐ 5PM PST  ATTN:  SERVICE DEPARTMENT (RA#‐‐‐‐‐‐‐‐)  OMNISISTEM LIGHTS & EFFECTS  6403 SOUTH 208th STREET  KENT, WA 98032  TEL:  253‐395‐9500  FAX:   253‐395‐9494       HOURS OF OPERATION:  MONDAY – FRIDAY 10AM ‐ 4PM PST  WWW.OMNISISTEM.COM      LED ROLLING SCAN (EA ‐ 3020) Manual    2009‐08‐01  CODE:  POWER:  POWER CONSUMPTION:  FUSE:    LED SIZE:  LED POWER:  LED COUNT:    AMBIENT  TEMPERATURE:    FEATURES:          BEAM ANGLE:    CONTROL:        DIMENSIONS:  WEIGHT:    FEATURES      EA ‐ 3020   120V 60Hz  6W ( at maximum intensity)  1 A  5mm  0.08W  55 (18 Red, 20 Green, 17 Blue)   23° F ‐ 113° F ( ‐5° C ‐ 45° C)  BI‐DIRECTIONALLY ROTATING BARREL  SOUND ACTIVE MIRROR BARREL  EXTREMELY LONG LIFETIME (100,000 hr. rating)  VERY LOW POWER CONSUMPTION  INCLUDES HANGING BRACKET  60˚  DMX‐512 (3 CHANNELS)  SOUND ACTIVE  MASTER/SLAVE  48 x 23 x 22.5 cm  15.6 kg                                LED ROLLING SCAN (EA ‐ 3020) Manual    2009‐08‐01    IMPORTANT SAFETY INFORMATION                         This unit is intended for indoor use only.  Unit should be warmed up for 15 minutes before operating. For optimal effects, the system should be turned off  for 25 minutes after running continuously for 3 hours.  Ensure the power source is of the correct voltage for this fixture. Connect power through a direct switch circuit,  NOT a dimmer or variable circuit source.  Disconnect unit from power when not in use.  Do not install or operate the device in harmful environment conditions.   (i.e. extreme heat, cold, moisture or dust)  If the unit has been exposed to extreme environmental conditions or drastic temperature fluctuations,   ensure the unit is returned to room temperature before operating.  Do not block fan or ventilation slots while operating unit.   Do not move the device while in operation.   Do not aim smoke or bubble effects near unit.  Do not operate the unit during thunderstorms.  Disconnect power prior to servicing or cleaning unit.  Do not use solvents or abrasive cleaners to clean the unit. Use a damp cloth only.  Modification(s) to the device or power cord will result in termination of the dealer/manufacturer’s warranty.    Use safety cable for added security when installing the unit by the hanging bracket.   Avoid direct eye contact with the light source.  Do not connect this unit to a dimmer pack.  The safest way to disconnect your power cord from main power is to grip cord end and detach from plug.  Do not leave unit unattended while operating for extended periods of time or overnight.  Contact the nearest dealer or service center for assistance with operating your unit. Unauthorized tampering  can cause additional damage. All units opened by an unauthorized user will not be covered under warranty.      PANEL OVERVIEW / FUSE REPLACEMENT    To the left is a diagram displaying the back  panel for the LED Rolling Scan. This is where  the controller and other units would  connect via the DMX‐IN and DMX‐OUT  connectors. Dip switch settings are also set  at this panel.    FUSE REPLACEMENT:  Prior to working on your unit, disconnect  the main power source. The fuse can be  replaced by unscrewing the fuse cover with  a Phillips screw driver. Remove the fuse  carefully to ensure the fuse holder is not  damaged . Pull the fuse out of the fuse seat  and replace with a 1A fuse. Insert the fuse  seat back into the unit and secure with the  fuse cover to original position to protect the  fuse      LED ROLLING SCAN (EA ‐ 3020) Manual    2009‐08‐01    MAINTENANCE        The amount of maintenance is dependent on atmospheric conditions and frequency of use. The LED Rolling Scan  should be cleaned every 30 days to ensure maximum life expectancy. The housing must be cleaned with a damp, lint‐ free cloth. Never use alcohol or solvents to clean this unit or mirrors. The mirrors should be cleaned every 15 days as  they tend to build up residue due to  the use of fog/haze machines and use in smoking environments.      Disconnect the power cord from the main power prior to using any liquid to clean your unit.       DMX CONTROL SETTINGS      CHANNEL CH. 1  CH. 2  CH. 3  CH. 4                                                             DMX DIP SWITCH SETTINGS  FUNCTION  DIMMER/STROBE  RED DIMMER  GREEN DIMMER  BLUE DIMMER    1  1  2  2  3  4  4  8  5  16  6  32  7  64  8  128  9  256  10  AUTO        DIP SWITCHES ‐ 1,2,3 ON  RED ON    DIP SWITCHES ‐ 4,5,6 ON  GREEN ON  DIP SWITCHES ‐ 7,8 ON  AUTO COLOR CHANGE  DIP SWITCHES ‐ 1,9 ON  STROBE R to G to B    DIP SWITCHES ‐ 7,8 ON  BLUE ON      DIP SWITCHES ‐ 3,9 ON  COLOR CHANGE W/ SPEED CONTROL  (DIP SWITCH 1 & 2 CONTROL SPEED   WHILE 3 & 9 ARE ON)    DMX ON SETTINGS      ON  FUNCTION  10  DMX ON     (used in conjunction with dip switch selection)  LED ROLLING SCAN (EA ‐ 3020) Manual      2009‐08‐01        LINE  BROWN  BLUE  YELLOW/CYAN  ELECTRICAL        CONNECTION  Cathode  Anode  Ground Wire  INTERNATIONAL SYMBOL  L  N        TROUBLESHOOTING        If your unit does not turn on:     Check the  main power source is fully functional   Check power cord connection on each side   Check that the correct fuse has been installed and it is not blown      If the unit is not responding to sound:     Check that the dip switches at the rear of unit to have been set to sound activation   Check sensitivity switch at the rear of the unit       For additional information regarding operation of the unit or if you have a unit requiring service*,   contact the OmniSistem Technical Department at 253‐395‐9500 Monday – Friday  10am ‐ 4pm PST.      * All service items must be given an RA# prior to shipping to our facilities. You can acquire a RA # by calling our offices during regular  business hours. All service items must be shipped with a copy of original receipt if purchased within a year and covered under our  warranty policy. If the unit has been modified warranty is void.   LED ROLLING SCAN (EA ‐ 3020) Manual    2009‐08‐01