Lepc24 - Columbia Lighting

   EMBED


Share

Transcript

LEPC24 2' × 4' LED, e•poc® Full Distribution Luminaire PROJECT INFORMATION Project Name Type Catalog No. Date CONSTRUCTION Luminaire housing, end caps, and reflectors are die-formed code-gauge cold-rolled steel. Frameless optics system hinges from either side for easy access to lamps and electrical components. Mechanical light trap prevents light leaks. Latches are spring loaded. Fixture construction is standard static. Air handling return air side slots are available as option. FEATURES • High-performance LED luminaire • Long-life, 60,000 hour LEDs at L80 (80% lumen maintenance) reduce life cycle maintenance costs • DesignLights Consortium® qualified • Four LED color choices • Four lumen packages ranging from 3625 to 7250 nominal • Superior color consistency to a 3-step MacAdam ellipse and 82 CRI • Full distribution provides controlled high angle light for visual comfort • Lens design and materials provide uniform appearance without pixilation • Unique frameless optical system and modular electrical system allow for easy LED module or driver replacement from below the ceiling • Most configurations produce low W/ft2 to meet the most restrictive lighting power density codes • U.S. Transformed ORDERING INFORMATION LEPC 24 – MODEL LEPC e∙poc® LED Full Distribution Luminaire COLOR TEMP 30 35 40 50 XW VW MW LW ML HL VL XL SHIELDING Lenses are high transmission extruded acrylic. INSTALLATION An access plate is furnished with each recessed fixture for fast wiring connections without the necessity to open the fixture or wireway. WARRANTY Five year warranty. (Terms and Conditions apply) – LL – EXAMPLE LEPC24-35LWG-LL-EDU – U – AIR FUNCTION DRIVER VOLTAGE G Grid SM Surface Mount For hard ceilings use flange kit. Blank Static A Air Return Side Slots E Fixed Output ED 0-10V Dimming ED1 0-10V 1% Dimming LUTH Hi-lume 1% EcoSystem LED driver with Soft-on, Fade-toBlack dimming technology LUT5 5-Series EcoSystem LED driver ESD Fixed Output / Step Dimming4 U 120V-277V Extra Low Watt Very Low Watt Medium Low Watt Low Watt Medium Lumen High Lumen Very High Lumen Extra High Lumen SHIELDING LL Low Lamp Image (See Product Availability Table Below) In-Fixture Module Antenna adds 2" to overall fixture height at specific location. Not available with Surface Mount ceiling types. 3 For compatibility with Dual-Lite LiteGear® inverters in lieu of installed Battery Pack, contact Hubbell Lighting Representative. 4 Can be converted to fixed output by tying the hot leads together. 1 2 ACCESSORIES (ORDER SEPARATELY) Protected by US Patents D603,999; D604,446. Additional US and Canada Patents Pending. Specifications subject to change without notice. OPTIONS C388 C488 C588 GLR NYC RM ELL14 3-Wire Flex 4-Wire Flex 5-Wire Flex Fast Blow Fuse NYC Compliant Row Mount Emergency Battery Pack Installed, 1400 Lumens3 GTD Generator Transfer Device CP Chicago Plenum PRODUCT AVAILABILITY SIZE LUMEN PACKAGE XW VW MW LW 2'x4' ML HL VL XL FK24 2' ×4' Single Flange Kit FKCR Flange Kit Row Adaptor Damp Label - standard IC Rating - standard Page 1/3 Rev. 08/23/17 CERTIFICATION All luminaires are built to UL1598 and 2108 standards, and bear appropriate CSA labels. Damp location labeling is standard. Emergency equipped fixtures labeled UL924. Adheres to LM79, LM80 and TM21 standards. IC rating is standard on all models. Designlights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org. UL Sanitation Approved CEILING TYPE LUMEN OUTPUT SIZE 24 2' × 4' 3000K 3500K 4000K 5000K FINISH All visible parts are custom formulated soft, nonglare high-reflectance white powder coat finish, painted after fabrication. CEILING COMPATIBILITY Luminaire fits recessed exposed grid ceilings (G); four integral T-Bar clips standard. A flange kit (FK) option is available for recessed hard ceiling applications. Surface Mount (SM) option allows placement on ceiling plane. Cable Mount option (CM) allows suspension below ceiling plane. For information on compatibility with specific ceilings, or where plenum depth is a problem, contact your Hubbell Lighting representative. NOMINAL LUMENS (4000K) 2500-2700 3100-3350 3400-3700 4000-4300 4650-5000 5400-5900 6900-7500 8200-8900 NOMINAL WATTS 24 29 32 38 45 53 70 91 LUMENS PER WATT 104-113 107-116 106-116 105-115 103-111 102-111 100-107 90-98 Actual lumens will vary according to color temperature and other factors. For exact lumens and watts see specific photometric test(s). RECESSED ARCHITECTURAL / LEPC24 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LEPC24 2' × 4' LED, e•poc® Full Distribution Luminaire PHOTOMETRIC DATA LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Shielding Angle Spacing Criterion Luminous Opening in Feet Test 14.00748 Test Date 11/13/2014 ZONAL LUMEN SUMMARY LEPC24-40LWG-LL-EDU LEPC Epoc LED Full Distribution, Recessed Architectural 2 x 4 LED with frosted linear prismed lenses D700C30UNVTZ-C 1.00 LED 3635 28.60 0º = 90 90º = 90 0º = 1.19 90º = 1.25 Length: 3.85 Width: 1.88 Height: 0.00 Zone 0-30 INDOOR CANDELA PLOT Lumens % Lamp % Fixt. 1023 28.1 90 28.1 0-40 1656 45.6 45.6 0-60 2879 79.2 79.2 0-90 3635 100.0 100.0 0-180 3635 100.0 100.0 75 700 ENERGY DATA 60 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 COMPLIANCE Comparative Yearly Lighting Energy Cost per 1000 Lumens 127 Noncompliant $1.92 based on 3000 hrs. and $0.08 per KWH 1400 0 15 0.0 30 Horiz 0-180 45.0 45 90.0 Test 14.00749 Test Date 11/13/2014 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Shielding Angle Spacing Criterion Luminous Opening in Feet ZONAL LUMEN SUMMARY LEPC24-40MLG-LL-EDU LEPC Epoc LED Full Distribution, Recessed Architectural 2 x 4 LED with frosted linear prismed lens D10CC55UNVT-C 1.00 LED 4647 37.40 0º = 90 90º = 90 0º = 1.19 90º = 1.25 Length: 3.85 Width: 1.88 Height: 0.00 Zone 0-30 INDOOR CANDELA PLOT Lumens % Lamp % Fixt. 1307 28.1 90 28.1 0-40 2117 45.6 45.6 0-60 3681 79.2 79.2 0-90 4647 100.0 100.0 0-180 4647 100.0 100.0 75 850 ENERGY DATA 60 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 COMPLIANCE Comparative Yearly Lighting Energy Cost per 1000 Lumens 124 Noncompliant $1.90 based on 3000 hrs. and $0.08 per KWH 1700 0 15 0.0 30 Horiz 0-180 45.0 45 90.0 Test 14.00750 Test Date 11/13/2014 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Shielding Angle Spacing Criterion Luminous Opening in Feet ZONAL LUMEN SUMMARY LEPC24-40HLG-LL-EDU LEPC Epoc LED Full Distribution, Recessed Architectural 2 x 4 LED with frosted linear prismed lenses D10CC55UNVT-C 1.00 LED 5199 42.00 0º = 90 90º = 90 0º = 1.19 90º = 1.25 Length: 3.85 Width: 1.88 Height: 0.00 Zone INDOOR CANDELA PLOT Lumens % Lamp % Fixt. 0-30 1462 28.1 90 28.1 0-40 2368 45.6 45.6 0-60 4117 79.2 79.2 0-90 5199 100.0 100.0 0-180 5199 100.0 100.0 75 950 ENERGY DATA 60 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 COMPLIANCE Comparative Yearly Lighting Energy Cost per 1000 Lumens 124 Noncompliant $1.94 based on 3000 hrs. and $0.08 per KWH 1900 0 15 0.0 Page 2/3 Rev. 08/23/17 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com 30 Horiz 0-180 45.0 45 90.0 RECESSED ARCHITECTURAL / LEPC24 LEPC24 2' × 4' LED, e•poc® Full Distribution Luminaire PHOTOMETRIC DATA Test 14.00751 Test Date 11/13/2014 LUMINAIRE DATA ZONAL LUMEN SUMMARY Zone LEPC24-40VLG-LL-EDU LEPC Epoc LED Full Distribution, Recessed Architectural 2 x 4 LED with frosted linear prismed lenses D15CC55UNVTW-C 1.00 LED 7256 59.90 0º = 90 90º = 90 0º = 1.19 90º = 1.25 Length: 3.85 Width: 1.88 Height: 0.00 Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Shielding Angle Spacing Criterion Luminous Opening in Feet INDOOR CANDELA PLOT Lumens % Lamp % Fixt. 0-30 2040 28.1 90 28.1 0-40 3304 45.5 45.5 0-60 5745 79.2 79.2 0-90 7256 100.0 100.0 0-180 7256 100.0 100.0 75 1400 ENERGY DATA 60 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 COMPLIANCE Comparative Yearly Lighting Energy Cost per 1000 Lumens 121 Noncompliant $1.98 based on 3000 hrs. and $0.08 per KWH 2800 0 15 0.0 DIMENSIONAL DATA - GRID 30 Horiz 0-180 45.0 45 90.0 CEILING COMPATIBILITY Type G FKCR 33/8" 24" Side End For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. 24" For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK24 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK24 & (1) FKCR) FK24 Flange Kit 48" Side Flange kit cut out dimension for single unit only: 243/8" × 483/8" 4.270 2.98 48.850 For hard ceiling applications, order FK24 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. 3.776 .250 KOS 4 PLCS 5.770 3.01 2.98 4.244 4.500 4.244 5.000 25.015 9.920 4.270 3.01 DIMENSIONAL DATA - SURFACE MOUNT Row cut out dimensions using FK24s & FKCR adapters: Width 243/8", Length [48" × (# in row)] + 3/8". Example: (48" × 2) + 3/8" = 963/8" End Page 3/3 Rev. 08/23/17 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. RECESSED ARCHITECTURAL / LEPC24