Preview only show first 10 pages with watermark. For full document please download

Leuze Odsl8 Optical Distance Sensors

   EMBED


Share

Transcript

Leuze electronic ODSL 8 Optical laser distance sensors Dimensioned drawing 20 … 400mm 18 - 30 V DC l Reflection-independent distance information l Highly insensitive to extraneous light l Analogue current and voltage output l Measurement range and mode adjustable l Teachable switching output l M12 turning connector A B C D E We reserve the right to make changes • ods_12e.fm ISO 9001 IEC 60947... Transmitter Receiver Optical axis 90° turning connector LED yellow, green Electrical connection IP 67 IEC 60947... Accessories: (available separately • see page 72) l l l l Mounting systems Programming software Ready-made cable KB 448-2000-8A Control guard Leuze electronic GmbH + Co KG http://www.leuze.de Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730 ODSL 8/V... - 04 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: [email protected] – 56 – Leuze electronic ODSL 8 Specifications Tables Optical data Measurement range 1) Resolution Light source Wavelength Light spot diameter Laser class Laser warning notice 20 … 400mm 0.1mm laser (modulated light) 650 nm (visible red light) divergent, 1x6mm at 400m 2 acc. to EN 60825-1 (2003/10) see remarks Error limits Absolute measurement accuracy 1) ± 1% up to 200mm / ± 2% 200 … 400mm (6 … 90% diffuse reflection) Repeatability 2) ± 0.25% up to 200mm / ± 1% 200 … 400mm (6 … 90% diffuse reflection) Linearity 0.5% at 90% (white) Timing Measurement frequency Response time Delay before start-up 200Hz / 5ms measurement time £ 20 ms £ 300ms Electrical data Operating voltage UB Residual ripple Bias current Switching output Signal voltage high/low Analogue output Indicators LED green continuous light flashing off LED yellow continuous light flashing off 18 … 30VDC (incl. residual ripple) £ 15% of UB £50mA PNP transistor, high-active ³ (UB -2V)/£ 2V RL ³2kW (voltage) RL £ 500 W (current) teach-in on GND Diagrams teach-in on +UB ready for operation error teaching procedure no voltage object inside teach-in measurement distance teaching procedure object outside teach-in measurement distance Mechanical data Housing Optics cover Weight Connection type metal glass 70g M12 connector, 8-pin, turning Environmental data Ambient temp. (operation/storage) Protective circuit3) VDE safety class 4) Protection class Standards applied 1) 2) 3) 4) -20°C … +50°C/-40°C … +70°C 2, 3 II, all-insulated IP 67 IEC 60947-5-2 Remarks Luminosity coefficient 6% ... 90%, over complete temperature range, measured object ³ 50x50mm² Same object, measured object ³ 50x50mm² 2=polarity reversal protection, 3=short-circuit protection for all outputs Rating voltage 250VAC A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance l Switching frequency depends on the reflectivity of the measured object and on the measurement mode. l Teaching procedure: Position measured object at desired measurement distance. Connect teach input to +UB for ³ 2s. Reconnect teach input to GND, switching output is programmed. l In the analogue version, the voltage output is calibrated. Order guide Designation M12 connector ODSL 8/V4-400-S12 500 39614 Programming terminal UPG 5 500 39627 ODSL 8/V... - 04 0404 – 57 – www.ctiautomation.net - Email: [email protected] CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: