Preview only show first 10 pages with watermark. For full document please download

Lg Window-type Air Conditioner

   EMBED


Share

Transcript

website http://www.lgservice.com OWNER'S MANUAL MODELS, MODELOS: WL Series: LW1004ER LW1204ER LW1404ER WP Series: LW1804ER IMPORTANT Please read through this manual. It contains valuable information about your air conditioner. This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use. PRECAUTIONS Pay close attention to precautions in order to prevent potential hazards and damage from misuse or improper installation. LG is not responsible for any damages caused by misuse of the air conditioner. ESPAÑOL LG Window-Type Air Conditioner ENGLISH LG Window-Type Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name 1. Safety Precautions Date Purchased ■ Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues. 2. Operating Instructions 3. Care and Maintenance READ THIS MANUAL 4. Hardware Installation Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. 5. Common Issues You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all. PRECAUTION • Contact the authorized service technician for repair or maintenance of this unit. • Contact the installer for installation of this unit. • The air conditioner is not intended for use by young children or invalids without supervision. • Young children should be supervised to ensure that they do not play with the air conditioner. • When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts. • Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only. 2 Safety Precautions Precautions WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to properties only. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING ■ Installation Always install the expansion panel(s). Do not place the power cord near a heater. • No installation may cause fire and electric shock accident. • It may cause fire and electric shock. Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc. Do not disassemble or modify products. • It may cause explosion or fire. • It may cause failure and electric shock. Gasolin 3 ENGLISH To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. ■ Operation Plug in the power plug properly. • Otherwise, it will cause electric shock or fire due to heat generation or electric shock. Do not modify power cord length. • It will cause electric shock or fire due to heat generation. Unplug the unit if strange sounds, odors, or smoke come from it. • Otherwise it may cause fire and electric shock accident. Do not operate or stop the unit by inserting or pulling out the power plug. Do not damage or use an unspecified power cord. • It will cause electric shock or fire due to heat generation. • It will cause electric shock or fire. ON Do not share the outlet with other appliances. • It will cause electric shock or fire due to heat generation. Do not use the socket if it is loose or damaged. • It may cause fire and electric shock. 4 Always plug into a grounded outlet. • No grounding may cause electric shock (See Installation Manual). Do not operate with wet hands or in damp environment. • It will cause electric shock. Do not allow water to run into electric parts. • It will cause failure of machine or electric shock. Leave the door closed while the air conditioner is running. • It is not designed to cool the entire house. Ventilate before operating air conditioner when gas goes out. • It may cause explosion, fire, and burn. ENGLISH CAUTION ■ Installation Never touch the metal parts of the unit when removing the filter. • They are sharp and may cause injury. Do not block the inlet or outlet. • It may cause failure of appliance or accident. Ensure that the outer case is not damaged by age or wear. • If leaving appliance damaged, there is concern of damage due to the falling of product. ■ Operation Be cautious not to touch the sharp edges when installing. • It may cause injury. Hold the plug by the head when taking it out. • It may cause electric shock and damage. Sharp edges 5 Turn off the main power switch when not using it for a long time. • Prevent accidental startup and the possibility of injury. Do not place heavy object on the power cord and take care so that the cord should not be pressed. If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the power-plug out from the socket. • There is danger of fire or electric shock. Turn off the power and breaker firstly when cleansing the unit. • Since the fan rotates at high speed during operation, it may cause injury. Always insert the filter securely. Clean it every two weeks. • Operation without filters will cause failure. Do not clean the air conditioner with water. • Water may enter the unit and degrade the insulation. It may cause an electric shock. Do not put a pet or house plant where it will be exposed to direct air flow. • This could injure the pet or plant. Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. • The appearance of the air conditioner may deteriorate, change color, or develop surface flaws. x Wa Thinner 6 Do not use this appliance for special purposes such as pets, foods, precision machinery, or objects of art. • It is an air conditioner, not a precision refrigeration system. Do not drink water drained from air conditioner. / Do not direct airflow at room occupants only. • It contains containments and will make you sick. / This could damage your health. Safety Precautions Prior to Operation ENGLISH Preparing for operation 1 Contact an installation specialist for installation. 2 Plug in the power plug properly. 3 Do not share the same outlet with other appliances 4 Do not use an extension cord. 5 Do not start/stop operation by plugging/unplugging the power cord. 6 If cord/plug is damaged, replace only with an authorized part. Usage 1 Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time. 2 Due to the possibility of oxygen deficiency, ventilate the room when using together with stoves or other heating devices. 3 Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Usage in such a manner could harm such property. Cleaning and maintenance 1 Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. 2 Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. 3 When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is accidentally triggered on while cleaning inner parts of the unit. Service For repair and maintenance, contact your authorized service dealer. 7 Operating Instructions Remote Control Operations The remote control and control panel will look like those represented in the following pictures. 6 COOL FAN DRY FAN INDOOR TIMER 5 ENERGY SAVER DESIRED AIR PURIFIER CLEAN FILTER FAN SPEED MODE 4 3 TEMP POWER 2 1 Power 1 Temp 2 Fan Speed 4 Timer Mode 3 5 8 4 FAN SPEED SELECTOR 1 POWER Operation starts when this button is pressed and stops when you press the button again. For increased power while cooling, select a higher fan speed. 3 steps: High ➔ Low ➔ Med 2 TEMPERATURE CONTROL 5 ON/OFF TIMER The thermostat monitors room temperature to maintain the desired temperature. The thermostat can be set between 60°F~86°F (16°C~30°C). The unit takes an average of 30 minutes to adjust the room temperature by 1°F. The timer can be set to start and stop the unit in hourly increments (up to 12 hours). 6 REMOTE CONTROL SENSOR 3 OPERATION MODE SELECTOR Select cooling mode to cool the room. Select energy saver mode for energy saving operation. Select fan mode for basic ventilating fan operation. Select dry mode for dry operation. AUTO RESTART In failure of electric power, the unit runs as previous setting operation. Inserting the Remote Control Batteries 1 Push out the cover on the back of the remote control with your thumb 2 Pay attention to polarity and insert two new AAA 1.5V batteries. 3 Reattach the cover. NOTICE : Do not use rechargeable batteries. Make sure that both batteries are new. • In order to prevent discharge, remove the batteries from the remote control if the air conditioner is not going to be used for an extended period of time Keep the remote control away from extremely hot or humid places. To maintain optimal operation of the remote control, the remote sensor should not be exposed to direct sunlight. • The remote control can be mounted on a wall using the mountable holder. 9 ENGLISH Remote Control Operations Operating Instructions Adjusting the Air Flow Direction Vent Control For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air. CLOSE NOTICE VENT Part A OPEN : Before using the ventilation feature, position the vent lever by pulling Part A out straight and snapping it into place. Adjusting the Air Flow Direction Airflow can be adjusted by changing the direction of the air conditioner's louvers. This can also increase the cooling efficiency of the air conditioner. • Adjusting Horizontal Air Flow Direction Adjusting the vertical louvers left and right will change horizontal airflow. • Adjusting Vertical Air Flow Direction Adjusting the horizontal vane up and down will change vertical airflow. The vane can be adjusted by nudging the vane backward or forward. Adjusting horizontal air flow Adjusting vertical air flow • Recommended orientation of louvers Adjust louvers to face upwards when cooling to maximize cooling efficiency. 10 Care and Maintenance Care and Maintenance Air Filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner. How to remove the air filter 1 The grille may be opened from the top for easy maintenance after installation. 2 Open the inlet grille by pulling off the exposed door on the top of the unit (based on installation). 3 Pull the tab slightly to release the filter. Pull the filter in the same direction as the opening. 4 Clean the filter with warm, soapy water. The water should be below 40°C (104°F). 5 Rinse off and gently shake off excess water from the filter. Let it dry before replaceing it. Drainage The base pan may overflow due to high humidity. To drain the excess water, remove the drain cap from the back of the unit and secure the drainpipe. When pressing the drainpipe into place, apply force in the direction away from the fins to avoid injuring yourself. Drain pipe Drain cap 11 ENGLISH Turn the power off and unplug the power plug before cleaning the air conditioner. How to Attach Drain Pan (Optional) The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the air) is drained to the outside. In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water removed from the air may cause some water to collect. To remove this excess water you can install the drain pan as detailed below. 1 Take the drain pan which is located in the air discharge. CABINET 2 Remove the hole rubber from the base-pan (for some models). 3 DRAIN PAN Install the drain pan to the right corner of the cabinet with 4 (or 2) screws. SCREW DRAIN HOSE 4 Connect the drain hose of 3/5" inside diameter to the outlet located at the bottom of the drain pan.You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied). 12 Hardware Installation Hardware Installation CAUTION: This appliance should be installed in accordance with national wiring regulations. The following information serves acts as a guide to help to explain product features. 13 6 5 8 1 7 11 9 14 12 2 4 3 15 1. CABINET 2. FRONT GRILLE 3. AIR FILTER 4. AIR INTAKE (INLET GRILLE) 5. AIR DISCHARGE 6. VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) 7. EVAPORATOR 10 8. HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) 9. CONTROL PANEL 10. POWER CORD 11. COMPRESSOR 12. BASE PAN 13. BRACE 14. CONDENSER 15. REMOTE CONTROLLER Installing the Power cord You can choose between two methods below according to your window stool shape and preference. Using slit "A" Using slit "B" • Fasten the stopper using 2 screw holes, and lead out the power cord through slit "A". • Fasten the stopper using left screw hole, and rotate properly to lead the power cord out through slit "B". A B Power cord Power cord 13 ENGLISH Product Features WK Series How to Install the Unit 1 To prevent vibration and noise, make sure the unit Fence is installed securely and firmly. Awning 2 Install the unit where the sunlight does not shine directly on the unit. Cooled air Heat radiation at least 12" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner. 30"~60" 3 The outside of the cabinet must extend outward for About 1/2" Over 20" CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4 Install the unit a little slanted so the back is slightly lower than the front (about 1/2"). This will force condensed water to flow to the outside. 5 Install the unit with the bottom about 30"~60" above the floor level. Window Requirements NOTICE : All supporting parts should be secured to firm wood, masonry, or metal. • This unit is designed for installation in standard double hung windows with actual opening widths from 25" to 36". • The top and bottom window sash must open sufficiently to allow a clear vertical opening of 15" from the bottom of the upper sash to the window stool. 25" to 36" 15" min (With frame curtain) Stool Offset 1/2" to 11/4" Sill Interior wall 20 1/12" min. (Without frame curtain) 14 Exterior WL Series 1 To prevent vibration and noise, make sure the unit Fence is installed securely and firmly Awning 2 Install the unit where the sunlight does not shine directly on the unit. Cooled air Heat radiation at least 12" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner. 30"~60" 3 The outside of the cabinet must extend outward for About 1/2" Over 20" CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4 Install the unit a little slanted so the back is slightly lower than the front (about 1/2"). This will force condensed water to flow to the outside. 5 Install the unit with the bottom about 30"~60" above the floor level. Window Requirements NOTICE : All supporting parts should be secured to firm wood, masonry, or metal. • This unit is designed for installation in standard double hung windows with actual opening widths from 27" to 39". • The top and bottom window sash must open sufficiently to allow a clear vertical opening of 16" from the bottom of the upper sash to the window stool. 27" to 39" 16" min (With frame curtain) Stool Offset 1/2" to 11/4" Sill Interior wall 23 5/8" min. (Without frame curtain) 15 Exterior ENGLISH How to Install the Unit WP Series How to Install the Unit 1 To prevent vibration and noise, make sure the unit Fence is installed securely and firmly. Awning 2 Install the unit where the sunlight does not shine directly on the unit. Cooled air Heat radiation 3 There should be no obstacles, such as a fence and 30"~60" wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner. About 1/2" Over 20" CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4 Install the unit a little slanted so the back is slightly lower than the front (about 1/2"). This will force condensed water to flow to the outside. 5 Install the unit with the bottom about 30"~60" above the floor level. Window Requirements NOTICE : All supporting parts should be secured to firm wood, masonry, or metal. • This unit is designed for installation in standard double hung windows with actual opening widths from 29" to 41". • The top and bottom window sash must open sufficiently to allow a clear vertical opening of 18" from the bottom of the upper sash to the window stool. Sash 29" to 41" 18" min. Inner sill Window Offset Sill Exterior Interior wall 29" min. (Without frame curtain) 16 WK, WL Series 2 1 5 6 3 4 7 8 NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 13 10 12 9 11 NAME OF PARTS FRAME CURTAIN SILL SUPPORT BOLT NUT SCREW (TYPE A) SCREW (TYPE B) SCREW (TYPE C) FOAM-STRIP DRAIN PIPE FOAM-PE FRAME GUIDE WINDOW LOCKING BRACKET FOAM-PE Q'TY 2 2 2 2 16 3 5 1 1 1 2 1 1 Suggested Tool Requirements SCREWDRIVER(Philips and Flatead), RULER, KNIFE, HAMMER, PENCIL, LEVEL PREPARATION OF CHASSIS Shipping Screws 1 Remove the screws which fasten the cabinet at both sides and at the back. 2 Slide the unit from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet. 3 Cut the window sash seal to the proper length. Peel off the backing and attach the Foam-PE underside of the window sash. to the 4 Remove the backing from the top upper guide Foam-PE and attach it to the bottom of the Upper Guide. 5 Attach the upper guide onto the top of the cabinet with 3 Type A screws . 6 Insert the Frame Guides Upper guide into the bottom of the cabinet. 13 7 Insert the Frame Curtain Frame Guides 10 into the Upper Guide and (Type A) . Upper guide 5 8 Fasten the curtains to the unit with 4 Type A screws . 11 5 11 5 17 (Type A) ENGLISH Installation Kits Contents Cabinet Installation 1 Open the window. Mark a line on center of the window stool. Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked in the window stool. Upper Guide Window stool Front Angle Fig. 1 2 Pull the bottom window sash down behind the Upper Guide until it meets. NOTICE Window Sash : Do not pull the window sash down tightly that the movement of Frame Curtain is restricted. Foam-pe 13 Cabinet Frame Curtain Upper guide 1 Foam-pe 10 Fig. 2 3 Loosely assemble the Sill Support using the parts in Fig. 3. INDOOR OUTDOOR Sill Support Bolt 3 Nut 2 4 Fig. 3 4 Select the position that will place the Sill Support Screw(Type A) near the outer most point on sill (See Fig. 4) About 1/2" NOTICE 5 Frame Guide 11 : Be careful when you install the cabinet (Frame Guides are broken easily). Cabinet 5 Attach the Sill Support to the cabinet track hole in relation to the selected position using 2 Type A screws in each support (See Fig. 4). INDOOR OUTDOOR Fig. 4 18 Screw(Type B) 6 About 1/2" (about 1/2") downward toward the outside (See Fig. 5). Adjust the bolt and the nut of Sill Support balancing the cabinet. for Sill Support 7 Attach the cabinet to the window stool by driving (Type B: Length 16mm (5/8 inch) the screws and below.) through the front angle into window stool. 2 Sash track 8 Pull each Frame Curtain fully to each window sash track, and repeat step 2. Front Angle Screw(Type B) Sill Support 6 2 Fig. 5 9 Attach each Frame Curtain screws the window sash using (Type C). (See Fig. 6) Type C CAUTION: Do not drill a hole in the bottom pan. The unit is designed to operate with approximately 1/2" of water in bottom pan. There is no need to add water if the pan is dry. 7 Fig. 6 10 Slide the unit into the cabinet. (See Fig. 7) CAUTION: For security purpose, reinstall screws (Type A) at cabinet's sides. Screw(Type A) Power cord Screw (Type A) Fig. 7 11 Cut the Foam-Strip to the proper length and insert between the upper window sash and the lower window sash. (See Fig. 8) Foam-Strip 8 Fig. 8 19 ENGLISH 6 The cabinet should be installed with a very slight tilt 12 Attach the Window Locking Bracket C screw with a Type . (See Fig. 9) Window locking bracket 12 Fig. 9 13 Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (See Fig. 10) Fig. 10 14 Pull down the inlet grille and secure it with a Type A screw through the front grille. (See Fig. 11) 15 Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. Fig. 11 20 WP Series 1 2 6 15 7 8 9 3 4 10 NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5 11 13 12 14 NAME OF PARTS FRAME CURTAIN SUPPORT BRACKET SILL BRACKET LOCK NUT SCREW (TYPE A) SCREW (TYPE B) SCREW (TYPE C) SCREW (TYPE D) CARRIAGE BOLT FOAM STRIP FOAM SEAL WINDOW LOCKING BRACKET DRAIN PIPE FOAM-PE FRAME GUIDE Q'TY 2 2 2 4 14 7 5 2 2 1 1 1 1 1 2 Suggested Tool Requirements SCREWDRIVER(Philips and Flatead), RULER, KNIFE, HAMMER, PENCIL, LEVEL Shipping Screws PREPARATION OF CHASSIS 1 Remove the screws which fasten the cabinet at both sides and at the back. COOL FAN DRY HEAT INDOOR FAN DEFROS T DESIRED ENERGY SAVER AIR PURYFIE AUTO RESTARTR 2 Slide the unit from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet. 3 Cut the window sash seal to the proper length. Peel off the backing and attach the Foam-Seal underside of the window sash. to the COOL FAN DRY HEAT INDOOR FAN DEFROS T DESIRED ENERGY SAVER 4 Remove the backing from the top upper guide Foam-PE AIR PURYFIE AUTO RESTAR R T and attach it to the bottom of the Upper Guide. 5 Attach the upper guide onto the top of the cabinet with 3 Type A screws . 6 Insert the Frame Guides Upper guide into the bottom of the cabinet. 11 7 Insert the Frame Curtain Frame Guides into the Upper Guide and 14 Upper guide . 8 Fasten the curtains to the unit with 10 Type A screws . (Type A) 5 15 21 5 (Type A) ENGLISH Installation Kits Contents Cabinet Installation 1 Open the window. Mark a line on the center of the window stool between the side window stop moldings. Loosely attach the sill bracket to the support bracket using the carriage bolt and the lock nut. Sill Bracket 3 Support Bracket 2 Carriage Bolt 9 Lock nut 4 Fig. 12 Machine screw(Type D) and lock nut 2 Attach the sill bracket to the window sill using the screws (Type B). Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked window stool. Cabinet Track hole Outer edge of window sill Support Bracket 2 6 (Type B) Sill bracket 3 Carriage bolt and lock nut Fig. 13 3 Using the M-screw and the lock nut, attach the support bracket to the cabinet track hole. Use the first track hole after the sill bracket on the outer edge of the window sill. Tighten the carriage bolt and the lock nut. Be sure the cabinet slants outward. CAUTION: Do not drill a hole in the bottom pan. The unit is designed to operate with approximately 1/2" of water in bottom pan. Upper Guide Window stool Front angle 4 Pull the bottom window sash down behind the Top Window sash Fig. 14 Upper Guide retainer bar until they meet. NOTICE :1. Do not pull the window sash down so tightly that the movement of Frame curtain is restricted. Attach the cabinet to the window stool by driving the screws (Type B) through the cabinet into window stool. 2. The cabinet should be installed with a very slight tilt downward toward the outside. 22 Foam -Seal 11 Cabinet Frame curtain Foam-PE 14 Fig. 15 track, and pull the bottom window sash down behind the Top retainer bar until it meets. Sash track Front Angle 6 Screw(Type B) Fig. 16 6 Attach each Frame curtain the window sash by using screws (Type C.) (See Fig. 17) 7 (Type C) Fig. 17 7 Slide the unit into the cabinet.(See Fig. 18) COOL CAUTION: For security purpose, reinstall screws(Type A) at cabinet's sides. FAN DRY HEAT INDOO FAN DEFRO ST R DESIR Screw Power Cord ED ENERG SAVER Y AIR PURYF AUTOIER RESTA RT Screw Fig. 18 8 Cut the Foam-strip to the proper length and insert between the upper window sash and the lower window sash.(See Fig. 19) Foam-Strip Fig. 19 9 Attach the Window locking bracket with a screw Window locking bracket (Type C.) (See Fig. 20) Fig. 20 23 ENGLISH 5 Pull each Frame curtain fully to each window sash 10 Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (See Fig. 21) 11 Lift the inlet grille and secure it with a screw (Type A) through the front grille.(See Fig. 21) R POWE TEMP MODE FAND SPEE TIME 12 Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. Fig. 21 Electrical Data Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut or remove the grounding prong from the plug. Power supply cord with 3-prong grounding plug Use 15 AMP, time delay fuse or circuit breaker. Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC Use of extension cords • Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated at 15A, 125V. Electrical Data (LW1804ER MODEL) Line Cord Plug Use Wall Receptacle Power Supply 230V/208V Use 15 AMP circuit. Refer to nameplate for correct fusing. tandem type All wirring should be made in accordance with local electrical codes and regulations. NOTICE : Aluminum house wiring may pose special problems. Consult a qualified electrician. 24 IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet (Fig. 22) to minimize the hazard of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded. Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores (Fig. 23). The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection. CAUTION: Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded through the house wiring. The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded. PREFERRED METHOD Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter ground terminal might break. DO NOT USE the appliance with a broken adapter plug. Ensure proper ground exists before use Fig. 22 DO NOT CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER PLUG. B. SITUATIONS WHEN THE APPLIANCE WILL BE DISCONNECTED OFTEN. Do not use an adapter plug in these situations. Unplugging the power cord frequently can lead to an eventual breakage of the ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet instead. A. SITUATIONS WHEN THE APPLIANCE WILL BE DISCONNECTED OCCASIONALLY: TEMPORARY METHOD USE OF EXTENSION CORDS Adapter plug Metal screw Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated at 15A, 125V. Receptacle cover Fig. 23 25 ENGLISH Electrical Safety Electrical Safety (LW1804ER MODEL) IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet (Fig. 24) to minimize the hazard of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded. 230, 208, and 230/208 VOLT UNITS These units are equipped with a three-prong grounding plug on the power supply cord, which must be plugged into a matching properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances. PREFERRED METHOD NOTICE 3-prong grounding type wall receptacle 3-prong grounding plug Ground prong Power supply cord Ensure proper ground exists before use Fig. 24 DO NOT CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER PLUG. FUSE – Use a time-delay fuse or circuit breaker. Refer to serial plate for proper power supply requirements. 26 : DO NOT USE AN EXTENSION CORD on 230, 208, and 230/208 Volt units. Common Issues Common Problems and Solutions The air conditioner is operating normally when: • You hear a pinging noise. This is caused by water being picked up by the condenser on rainy days or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency. • You hear the thermostat click. This is caused by the compressor cycle starting and stopping. • You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid conditions or on rainy days. This water overflows and drips from the rear of the unit. • You hear the fan running while the compressor is silent. This is a normal operational feature. The air conditioner may be operating abnormally when: Problem Possible Causes What To Do ■ The air conditioner is unplugged or • Make sure the plug is completely plugged into not plugged in completely the outlet The air conditioner does not operate at all Air conditioner does not cool ■ The fuse is blown/circuit breaker is • Check the fuse/circuit breaker box and replace triggered the fuse or reset the breaker ■ Power failure. • In the event of a power failure, set the power control to OFF. When the power is restored, wait 3 minutes to restart the air conditioner to prevent the compressor from overloading ■ Air flow is restricted • Make sure there are no curtains, blinds, furniture or other obstacles in front of the air conditioner ■ The THERMOSTAT may not be set cool enough • Turn the knob to a higher setting. The highest setting provides maximum cooling ■ The air filter is dirty. • Clean the filter at least every 2 weeks. Refer to the “Care and Maintenance” section (p.11) of the manual. ■ The air conditioner was just turned on. • After the air conditioner is turned on, you need to give the air conditioner some time to cool the room. ■ Cold air is escaping. • Check for open furnace floor resisters and cold air returns. • CLOSE the air conditioner vent Ice appears on the air conditioner. ■ Cooling coils are iced up • See Ice appears on the air conditioner below ■ The cooling coils are iced over. • Ice may block the air flow and obstruct the air conditioner from properly cooling the room. Set the fan at MED or HIGH while setting the thermostat at 1 or 2 until the ice melts. ❈ You can refer to the Energy Star program in detail at "www.energystar.gov". 2727 ENGLISH Before calling for service, please review the following list of common problems and solutions.