Transcript
Hyper SIDELED® Hyper-Bright Low Current LED Lead (Pb) Free Product - RoHS Compliant LG A67K, LP A67K
Released Features • package: white SMT package, colorless clear resin • feature of the device: radiation direction parallel to PCB, so an ideal LED for coupling in light guides • wavelength: 570 nm (green), 560 nm (pure green) • viewing angle: Lambertian Emitter (120°) • technology: InGaAlP • optical efficiency: 4 lm/W (green), 1.2 lm/W (pure green) • grouping parameter: luminous intensity, wavelength • assembly methods: suitable for all SMT assembly methods • soldering methods: reflow soldering • preconditioning: acc. to JEDEC Level 2 • taping: 12 mm tape with 2000/reel, ø330 mm • ESD-withstand voltage: up to 2 kV acc. to JESD22-A114-D • Superior Corrosion Robustness: details see page 9
Besondere Merkmale • Gehäusetyp: weißes SMT Gehäuse, farbloser klarer Verguss • Besonderheit des Bauteils: Abstrahlung parallel zur Platine, deshalb ideal zur Einkopplung in Lichtleiter • Wellenlänge: 570 nm (grün), 560 nm (pure green) • Abstrahlwinkel: Lambertscher Strahler (120°) • Technologie: InGaAlP • optischer Wirkungsgrad: 4 lm/W (grün), 1,2 lm/W (pure green) • Gruppierungsparameter: Lichtstärke, Wellenlänge • Verarbeitungsmethode: für alle SMT-Bestücktechniken geeignet • Lötmethode: Reflow Löten • Vorbehandlung: nach JEDEC Level 2 • Gurtung: 12-mm Gurt mit 2000/Rolle, ø330 mm • ESD-Festigkeit: ESD-sicher bis 2 kV nach JESD22-A114-D • Erweiterte Korrosionsfestigkeit: Details siehe Seite 9 Anwendungen • optischer Indikator • Einkopplung in Lichtleiter • Hinterleuchtung (LCD, Schalter, Tasten, Displays, Werbebeleuchtung) • Innenbeleuchtung im Automobilbereich (z.B. Instrumentenbeleuchtung) • Markierungsbeleuchtung • Signal- und Symbolleuchten
2012-06-15
Applications • optical indicators • coupling into light guides • backlighting (LCD, switches, keys, displays, illuminated advertising) • interior automotive lighting (e.g. dashboard backlighting) • marker lights • signal and symbol luminaire
1
LG A67K, LP A67K Bestellinformation Ordering Information Typ Type
Emissionsfarbe Color of Emission
Lichtstärke1) Seite 15 Luminous Intensity1) page 15 IF = 2 mA IV (mcd)
LG A67K-H2K1-24 LG A67K-G2K1-24
green
3.55 ... 9.00 2.24 ... 9.00
19 (typ.) 17 (typ.)
Q65110A2290 Q65110A2291
LP A67K-E1F2-25 LP A67K-F1G2-25 LP A67K-E1G2-25
pure green
0.71 ... 1.80 1.12 ... 2.80 0.71 ... 2.80
4 (typ.) 6 (typ.) 5 (typ.)
Q65110A2292 Q65110A2293 Q65110A2294
Anm.:
Lichtstrom2) Seite 15 Bestellnummer Luminous Ordering Code 2) page 15 Flux IF = 2 mA ΦV (mlm)
Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5 für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Gurt und Farbe geliefert. Z.B.: LG A67K-G2J1-24 bedeutet, dass auf dem Gurt nur eine der Helligkeitsgruppen G2, H1, H2 oder J1 enthalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppen nicht bestellt werden. Gleiches gilt für die Farben, bei denen Wellenlängengruppen gemessen und gruppiert werden. Pro Gurt wird nur eine Wellenlängengruppe geliefert. Z.B.: LG A67K-G2J1-24 bedeutet, dass auf dem Gurt nur eine der Wellenlängengruppen -2, -3 oder -4 enthalten ist (siehe Seite 5 für nähere Information). Um die Liefersicherheit zu gewährleisten, können einzelne Wellenlängengruppen nicht bestellt werden.
Note:
The above Type Numbers represent the order groups which include only a few brightness groups (see page 5 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LG A67K-G2J1-24 means that only one group G2, H1, H2 or J1 will be shippable for any one reel and color. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where wavelength groups are measured and binned, single wavelength groups will be shipped on any one reel. E.g. LG A67K-G2J1-24 means that only 1 wavelength group -2, -3 oder -4 will be shippable. In order to ensure availability, single wavelength groups will not be orderable (see page 5 for explanation).
Vergleichstabelle für 10 mA Correllation Table for 10 mA Typ Type
Emissionsfarbe Color of Emission
IF = 2 mA
Lichtstärke1)
Lichtstärke2)
Lichtstrom2)
Seite 15
Seite 15
Seite 15
Luminous Intensity1) page 15 IF = 2 mA IV (mcd)
Luminous Intensity2) page 15 IF = 10 mA IV (mcd)
Luminous Flux2) page 15 IF = 10 mA ΦV (mlm)
LG A67K-H2K1-24 green LG A67K-G2K1-24
3.55 ... 9.00 2.24 ... 9.00
LP A67K-E1F2-25 pure green LP A67K-F1G2-25 LP A67K-E1G2-25
0.71 ... 1.80 1.12 ... 2.80 0.71 ... 2.80
⇒ ⇒
Siehe auch Grafik auch Seite 7 / see also graph on page 7
2012-06-15
2
42 (typ.) 37 (typ.
125 (typ.) 110 (typ.
8 (typ.) 13 (typ.) 12 (typ.
25 (typ.) 40 (typ.) 35 (typ.
LG A67K, LP A67K Grenzwerte Maximum Ratings Bezeichnung Parameter
Symbol Symbol
Wert Value LG
Einheit Unit
LP
Betriebstemperatur Operating temperature range
Top
– 40 … + 100
°C
Lagertemperatur Storage temperature range
Tstg
– 40 … + 100
°C
Sperrschichttemperatur Junction temperature
Tj
+ 125
°C
Durchlassstrom Forward current (TA=25°C)
IF
20
mA
Stoßstrom Surge current t ≤ 10 µs, D = 0.005, TA=25°C
IFM
100
mA
Sperrspannung3)Seite 15 Reverse voltage3) page 15 (TA=25°C)
VR
12
V
Leistungsaufnahme Power consumption (TA=25°C)
Ptot
40
mW
Rth JA
480
K/W
Rth JS
250
K/W
Wärmewiderstand Thermal resistance Sperrschicht/Umgebung4)Seite 15 Junction/ambient4) page 15 Sperrschicht/Lötpad Junction/soldering point
2012-06-15
3
LG A67K, LP A67K Kennwerte Characteristics (TA = 25 °C) Bezeichnung Parameter Wellenlänge des emittierten Lichtes Wavelength at peak emission IF = 2 mA
Symbol Symbol (typ.)
Dominantwellenlänge5) Seite 15 Dominant wavelength5) page 15 IF = 2 mA
Werte Value
Einheit Unit
LG
LP
λpeak
572
562
nm
λdom
570* –4/+5
560* ±6
nm
Spektrale Bandbreite bei 50 % Irel max Spectral bandwidth at 50 % Irel max IF = 2 mA
(typ.)
∆λ
22
22
nm
Abstrahlwinkel bei 50 % IV (Vollwinkel) Viewing angle at 50 % IV
(typ.)
2ϕ
120
120
Grad deg.
Durchlassspannung6) Seite 15 Forward voltage6) page 15 IF = 2 mA
(min.) (typ.) (max.)
VF VF VF
1.7 1.8 2.2
1.7 1.8 2.2
V V V
Sperrstrom Reverse current VR = 12 V
(typ.) (max.)
IR IR
0.01 10
0.01 10
µA µA
Temperaturkoeffizient von λpeak Temperature coefficient of λpeak IF = 2 mA; –10°C ≤ T ≤ 100°C
(typ.)
TCλpeak
0.11
0.10
nm/K
Temperaturkoeffizient von λdom Temperature coefficient of λdom IF = 2 mA; –10°C ≤ T ≤ 100°C
(typ.)
TCλdom
0.10
0.10
nm/K
Temperaturkoeffizient vonVF Temperature coefficient of VF IF = 2 mA; –10°C ≤ T ≤ 100°C
(typ.)
TCV
– 2.3
– 2.5
mV/K
Optischer Wirkungsgrad Optical efficiency IF = 2 mA
(typ.)
ηopt
4
1.2
lm/W
* Einzelgruppen siehe Seite 5 Individual groups on page 5
2012-06-15
4
LG A67K, LP A67K Wellenlängengruppen (Dominantwellenlänge)5) Seite 15 Wavelength Groups (Dominant Wavelength)5) page 15 Gruppe Group
pure green
green
Einheit Unit
min.
max.
min.
max.
2
554
557
566
569
nm
3
557
560
569
572
nm
4
560
563
572
575
nm
5
563
566
nm
Helligkeits-Gruppierungsschema Brightness Groups Helligkeitsgruppe Brightness Group E1 E2 F1 F2 G1 G2 H1 H2 J1 J2 K1
Lichtstärke1) Seite 15 Luminous Intensity1) page 15 IV (mcd) 0.71 ... 0.90 ... 1.12 ... 1.40 ... 1.80 ... 2.24 ... 2.80 ... 3.55 ... 4.50 ... 5.60 ... 7.10 ...
Lichtstrom2) Seite 15 Luminous Flux2) page 15 ΦV (mlm) 2.5 (typ.) 3.0 (typ.) 3.8 (typ.) 4.8 (typ.) 6.0 (typ.) 7.6 (typ.) 9.5 (typ.) 12.0 (typ.) 15.0 (typ.) 19.0 (typ.) 24.0 (typ.)
0.90 1.12 1.40 1.80 2.24 2.80 3.55 4.50 5.60 7.10 9.00
Anm.: Die Standardlieferform von Serientypen beinhaltet eine untere bzw. obere Familiengruppe. Diese besteht aus 3 bzw. 4 Helligkeitsgruppen. Einzelne Helligkeitsgruppen sind nicht bestellbar. Note: The standard shipping format for serial types includes a lower or upper family group of 3 or 4 individual brightness groups. Individual brightness groups cannot be ordered.
Gruppenbezeichnung auf Etikett Group Name on Label Beispiel: H1-3 Example: H1-3 Helligkeitsgruppe Brightness Group
Wellenlänge Wavelength
H1
3
Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten. Note: No packing unit / tape ever contains more than one brightness group.
2012-06-15
5
LG A67K, LP A67K Relative spektrale Emission2) Seite 15 Relative Spectral Emission2) page 15 V(λ) = spektrale Augenempfindlichkeit / Standard eye response curve Irel = f (λ); TA = 25 °C; IF = 2 mA OHL00570
100 %
I rel 80
Vλ 60
40 pure-green
green
20
0 400
450
500
550
600
650
nm
700
λ Abstrahlcharakteristik2) Seite 15 Radiation Characteristic2) page 15 Irel = f (ϕ); TA = 25 °C 40˚
30˚
20˚
10˚
0˚
ϕ
50˚
OHL01660
1.0
0.8
0.6 60˚ 0.4 70˚ 0.2 80˚ 0
90˚ 100˚ 1.0 2012-06-15
0.8
0.6
0.4
0˚
20˚ 6
40˚
60˚
80˚
100˚
120˚
LG A67K, LP A67K Durchlassstrom2) Seite 15 Forward Current2) page 15 IF = f (VF); TA = 25 °C
Relative Lichtstärke2) 7) Seite 15 Relative Luminous Intensity2) 7) page 15 IV/IV(2 mA) = f (IF); TA = 25 °C OHL00801
10 2
OHL00802
10 2 mA
IV
IF
IV (2 mA) 10 1
10 1 10 0
10 -1
10 0 10 -2
10 -3 1.4
1.6
1.8
2.0
10 -1 0 10
V 2.2
10 1
mA
10 2
IF
VF Relative Lichtstärke2) Seite 15 Relative Luminous Intensity2) page 15 IV / IV(25 °C)= f (Tj); IF = 2 mA 3.0
OHL00800
IV IV (25˚C)
2.0
1.5
1.0
0.5
0 -60 -40 -20 0
20 40 60 ˚C 100
Tj 2012-06-15
7
LG A67K, LP A67K Maximal zulässiger Durchlassstrom Max. Permissible Forward Current I F = f ( T A)
IF
OHL01429
25 mA
TA
20
TS
15
10
5
TA temp. ambient TS temp. solder point 0
0
20
40
80 ˚C 100
60
T Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA = 25 °C 0.12 IF A
OHL02442
tP
D= T
0.10
0.08
0.06
0.04
Zulässige Impulsbelastbarkeit IF = f (tp) Permissible Pulse Handling Capability Duty cycle D = parameter, TA = 85 °C 0.12 IF A
tP IF T
tP
D= T
0.10
D= 0.005 0.01 0.02 0.05 0.1 0.2 0.5 1
0.08
0.06
0.04
0.02
tP IF T
D= 0.005 0.01 0.02 0.05 0.1 0.2 0.5 1
0.02
0 -5 10 10-4 10-3 10-2 10-1 100 101 s 102
0 -5 10 10-4 10-3 10-2 10-1 100 101 s 102
tp 2012-06-15
OHL02442
tp 8
LG A67K, LP A67K Maßzeichnung8) Seite 15 Package Outlines8) page 15
1.1 (0.043) Anode
(1.4 (0.055))
(R1)
3.8 (0.150) 3.4 (0.134)
(2.9 (0.114))
Cathode marking
(2.85 (0.112))
0.9 (0.035)
(0.3 (0.012))
Cathode
2.54 (0.100) spacing
0.7 (0.028)
4.2 (0.165) 3.8 (0.150)
2.4 (0.094)
2.8 (0.110)
(2.4 (0.094))
C
A
4.2 (0.165) 3.8 (0.150)
GPLY6880
Korrosionsfestigkeit besser als EN 60068-2-60 (method 4): mit erweitertem Korrosionstest: 40°C / 90%rh / 15ppm H2S / 336h Corrosion robustness better than EN 60068-2-60 (method 4): with enhanced corrosion test: 40°C / 90%rh / 15ppm H2S / 336h Kathodenkennung: Cathode mark: Gewicht / Approx. weight:
abgeschrägte Ecke bevelled edge 67 mg
Gurtung / Polarität und Lage8) Seite 15 Method of Taping / Polarity and Orientation8) page 15
Verpackungseinheit 2000/Rolle, ø330 mm Packing unit 2000/reel, ø330 mm
4 (0.157)
4.25 (0.167)
2012-06-15
8 (0.315)
9
12 (0.472)
1.75 (0.069)
Cathode/Collector Marking
5.5 (0.217)
2 (0.079)
3.95 (0.156)
1.5 (0.059)
OHAY2273
LG A67K, LP A67K Empfohlenes Lötpaddesign8) Seite 15 Recommended Solder Pad8) page 15
Reflow Löten Reflow Soldering
3.0 (0.118)
3.7 (0.146)
1.2 (0.047) Padgeometrie für verbesserte Wärmeableitung Paddesign for improved heat dissipation
Cu-Fläche > 16 mm 2 Cu-area > 16 mm 2 Lötstopplack Solder resist OHLPY965
2012-06-15
10
LG A67K, LP A67K Lötbedingungen Soldering Conditions Reflow Lötprofil für bleifreies Löten Reflow Soldering Profile for lead free soldering
Vorbehandlung nach JEDEC Level 2 Preconditioning acc. to JEDEC Level 2 (nach J-STD-020D.01) (acc. to J-STD-020D.01) OHA04525
300 ˚C
T 250
Tp 245 ˚C
240 ˚C
tP
217 ˚C 200
tL
150
tS
100
50 25 ˚C 0
50
0
100
150
200
250
s 300
t Anm.: Das Gehäuse ist nicht für nasschemische Reinigung geeignet. Note: Package not suitable for wetcleaning. Profile Feature
Pb-Free (SnAgCu) Assembly Recommendation
Max. Ratings
Ramp-up Rate to Preheat* 25°C to 150°C
2 K/ s
3K/s
Time ts from TSmin to TSmax (150°C to 200°C
100 s
min. 60sec max. 120sec
Ramp-up Rate to Peak*) 180°C to TP
2 K/ s
3K/s
)
Liquidus Temperture TL
217°C
Time tL above TL
80 s
max. 100 s
Peak Temperature TP
245 °C
max. 250 °C
Time tP within 5°C of the specified peak temperature TP - 5K
20 s
min. 10 s max. 30 s
Ramp-down Rate* TP to 100°C
3K/s
6 K / s maximum
Time 25°C to Peak temperature
max. 8 min.
All temperatures refer to the center of the package, measured on the top of the component * slope calculation ∆T/∆t: ∆t max. 5 s; fulfillment for the whole T-range
2012-06-15
11
LG A67K, LP A67K Barcode-Produkt-Etikett (BPL) Barcode-Product-Label (BPL) OSRAM Opto
BIN1: XX-XX-X-XXX-X
LX XXXX
Semiconductors
RoHS Compliant
(6P) BATCH NO: 1234567890
ML Temp ST 2 260 °C R (1T) LOT NO: 1234567890
(9D) D/C: 1234
Pack: R18 DEMY
022
B_R999_1880.1642 R (X) PROD NO: 123456789(Q)QTY: 9999 (G) GROUP: XX-XX-X-X
OHA04563
Gurtverpackung Tape and Reel W1 D0
P0
A N
F W
E
13.0 ±0.25
P2
Label
P1 Direction of unreeling
Direction of unreeling
W2
Gurtvorlauf: 400 mm 400 mm Leader: Gurtende: Trailer:
160 mm 160 mm
OHAY0324
Tape dimensions in mm (inch) W
P0
P1
P2
D0
E
F
12 + 0.3 – 0.1
4 ± 0.1 8 ± 0.1 2 ± 0.05 1.5 + 0.1 1.75 ± 0.1 5.5 ± 0.05 (0.157 ± 0.004) (0.315 ± 0.004) (0.079 ± 0.002) (0.059 + 0.004) (0.069 ± 0.004) (0.217 ± 0.002)
Reel dimensions in mm (inch) A 330 (13)
2012-06-15
W
Nmin
W1
W2 max
12 (0.472)
60 (2.362)
12.4 + 2 (0.488 + 0.079)
18.4 (0.724)
12
LG A67K, LP A67K Trockenverpackung und Materialien Dry Packing Process and Materials Moisture-sensitive label or print L VE el
LE . see lab e H) nk, (R bla cod y If bar . dit RH mi % hu e ve /60 ed ag ˚C ati rar ck rel 30 _ inf pa < % to ak of 90 urs d ). < ns (pe or urs d , Ho de cte itio Ho urs an bje ing ˚C co 72 nd Ho urs 5 te ˚C su ss 48 e Ho co ± ce 24 6 da e y 40 be tim ˚C h l pro < tor tim e e or ). 23 tim at t wilnt l wit or fac ˚C Flo s tim at or ca at re. Flo d tha ale el or nth nti Flo uiv du if: rea es l 4 5 Flo lab mo ide ce eq low g, l ve vic 5a is be de tin en 24 de , or pro ve l 6 Le e te co , g: un wh Le ve l ke r se da ba ed low ure Le ve mo % ba e ba al d Le ist ure en ref e e 10 ure tim for se ist ale op se for > se , Mo ure 3 ist is or . , is ha se Mo be nk ist nk rd g -03 Mo in n Flo r-p RH g, bla Mo ba TD po If blathi % kin Ca life s (if ar t. s wi 10 ba tor J-S thi, va p. elf Ye ar ek _ < e icat me , C 1 urs Ye er tem ted Sh at ed low uir > 1 WeHo un Aft Indno uir DE 1. dy d e 4 8 ref y is req 2. JE bo e Mo ore tim 16 req : C/ es dit2b a) tim e e St or mi IP ed or g is tim vic b) e Hu en Flo oror tim De 2a kin nc te Flo op a) 3. b) baere Flo or da e l 1 2 Flo If al ref tim ve l 2a 4. se d ve l 3 Le g an ve l Le Ba te ure Le ve Le ist ure Da ist ure Mo ure Mo istist Mo Mo
Barcode label
N RS ins VE ITI TO nta NSUC TIO U g coSEND CO Ais baRE TU MI CThIS SE MO TO OP
M RA OS
Humidity indicator Barcode label Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. Do not eat. Comparator check dot
WET
If wet, examine units, if necessary bake units
15%
If wet, examine units, if necessary bake units
10% 5%
If wet, parts still adequately dry. change desiccant Humidity Indicator MIL-I-8835
AM OS R
Desiccant
OHA00539
Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten. Note: Moisture-senisitve product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC.
Kartonverpackung und Materialien Transportation Packing and Materials
Barcode label
BA P) (6
M Y DE
R 18
-1 -1 +Q P
RO UP : G
4
01 4
C: D/ O D
NO :
20 00
(9 D)
T LO (1 T)
5 14 2 110 0
(Q )Q TY :
TC
O
H 12 34
S S em R ic AM o n O d u p ct to o H rs NO
998
PR (X )
D EM Y
18 R
-1
:
Q +
u L lt S iT Y O T6 P 7 L 6
P -1 G R O U P:
(G )
E Bi D Bi n1 Bi n2 : Pn3 : Q 1: -1 20 M -2 2 L 0 Te 2a 22 m 3 24 0 p ST Ad 26 0 C R C R ditio 0 C R 07 PA 7 na RT l TE C KV XT AR TY :2
AM
00
0
(9 D )
D /C :0
14 4
M
21 2100
)Q
(X )
PR O D
N O :
(1 T)
11 00
LO T
14 2
N O
5
O SR
(Q
A
21 00 21 99 8
o M n O d u p cto to rs
R
34
ic
N O :
H 12 G
O S
em
S
BA TC H
23
:1
(6 P)
:
el
23 G
e
(G )
M u L lt S iT Y O T6 P 7 L 6 E D
Muster
L
<
at
Muster
O M O PT O
NO :1
E V E
L selab . , H) nk de co (R bla r If ba . ity id RH m hu 0% e e /6 d tiv ˚C re ag la re fra ck 30 _ < in pa % k s of to 90 ea s ur d ). < ns or te (p d Ho ururs s , de g itio Ho an bjec co ˚C 72 sin nd Ho ur 5 te 48 ˚C su es e Ho co ± 24 6 da y 40 be oc tim e e ˚C or th r pr ll tim ct ). 23 oo r wi nt tim e l wi fa r Fl oo tim s at at le ˚C at e. ica l Fl th th va oo r ur nt Fl oo s ui be on if: read w ed l 4 5 Fl la m ide ce eq lo g, oc ve l vi is in en de be 24 de or l 5a6 pr Le ve nt wh e te co , w, g: ve l Le ke r re ou se da ba ed flo Le ve tu re m % ba e ba al e Le r en re e ed re 10 ois stu ur e tim se fo al op se fo > , M oi r se st ur 3 is is ha se M oi st nk be k, oo . 03 rd g M oi in an in Fl RH g, r-p bla DM ba Ca bl th po If % kinr life is (if . ar ST f p. wi 10 ba to et Jel r th va Ye ar ks s m _ < cat m d, C ed 1 Ye ee ur iredi Sh te w, te at nt > 1 W Ho Af flody qu In no ire DE 1. e ou 4 8 re ed re qu JE 2. bo ity is M or tim e e 16 re C/ : es id 2b r a) St tim m IP ed oo r or g is tim e vic b) e r Hu Fl oo en tim De 2a kin nc te Fl oo r a) op 3. b) ba re Fl oo da e fe l 1 Fl If al re tim ve l 2 4. se d l 2a3 Le ve g an ve l e Le Ba te ur e Le ve Le Da oist stur e ur e M oi st ur M oi st M oi M
Nns IVEORS ai IT ntNS CT TIO DU U g coSE ON Ais baRE IC TU M CThIS SE
Q : -1 M -2 2 L 0 Te 2a 22 m 3 24 0 p ST Ad 26 0 C R C R0 ditio 0 C R PA 77 na RT l TE CK VA XT R:
Bi Bi n1 Bi n2 : Pn3 : 120
Barcode label
Packing Sealing label Dimensions of transportation box in mm (inch) Breite / Width 352 ±5 (13,858 ±0,1968±)
2012-06-15
Länge / length
Höhe / height
352 ±5 (13,858 ±0,1968)
33 ±5 (1,3 ±0,1968)
13
OHA02044
LG A67K, LP A67K Revision History: 2012-06-15 Previous Version: 2009-12-14 Page
Subjects (major changes since last revision)
Date of change
2
ordering code canceled
2007-10-09
1, 9
additional information
2009-12-14
10, 11
OS-PCN-2012-008
2012-06-15
9
OS-IN-2012-017
2012-06-15
Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components9) page 15 may only be used in life-support devices or systems10) page 15 with the express written approval of OSRAM OS.
2012-06-15
14
LG A67K, LP A67K Fußnoten: 1)
2)
3) 4) 5) 6)
7)
8) 9)
10)
Remarks: 1) Brightness groups are tested at a current pulse duration of 25 ms and a tolerance of ± 11%.
Helligkeitswerte werden mit einer Stromeinprägedauer von 25 ms und einer Genauigkeit von ± 11% ermittelt. Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. Die LED kann kurzzeitig in Sperrichtung betrieben werden. RthJA ergibt sich bei Montage auf PC-Board FR 4 (Padgröße ≥ 16 mm2 je Pad) Wellenlängen werden mit einer Stromeinprägedauer von 25 ms und einer Genauigkeit von ±1 nm ermittelt. Spannungswerte werden mit einer Stromeinprägedauer von 1 ms und einer Genauigkeit von ±0,1 V ermittelt. Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden Maße werden wie folgt angegeben: mm (inch) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist.
2)
3) 4) 5) 6)
2012-06-15
7)
In the range where the line of the graph is broken, you must expect higher brightness differences between single LEDs within one packing unit.
8)
Dimensions are specified as follows: mm (inch) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system.
9)
10)
Published by OSRAM Opto Semiconductors GmbH Wernerwerkstrasse 2, D-93049 Regensburg www.osram-os.com © All Rights Reserved. 15
Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. Driving the LED in reverse direction is suitable for short term application. RthJA results from mounting on PC board FR 4 (pad size ≥ 16 mm2 per pad) Wavelengths are tested at a current pulse duration of 25 ms and a tolerance of ±1 nm. Forward voltages are tested at a current pulse duration of 1 ms and a tolerance of ±0.1 V.
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.