Transcript
High Voltage Solid State Relays General Information FEATURES 3750 Vrms or 5300 Vrms I/O isolation Current-limit protection built-in Linear ac/dc operation High-reliability monolithic receptor Extremely low leakage current (pA) High contact off-impedance (GW) Low power consumption (1 mW—12 mW) Very low switch offset (typically 0.1 mV) Logic compatible Clean, bounce-free switching Built-in 1 Form C break-before-make High surge capability Insensitive to dv/dt Surface mountable Compatible with UL1459 and FCC 68.302 UL recognized CSA certified BABT certificate of recognition to BS6301
• • • • • • • • • • • • • • • • • •
BENEFITS • Long life • Maintenance free • Current-limit SSRs can sustain repeated faults without damage Minimizes drive circuitry • • Noiseless • Immune to shock • Immune to environmental hazards such as salt, dirt, and humidity • No arcing • No mounting restrictions • Preapproved for DAA applications • High reliability • Easily configured in series or in parallel for increased voltage or current
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
DESCRIPTION Siemens Solid State Relays (SSRs) are miniature, optically-coupled relays with high-voltage MOSFET outputs. The relays are capable of switching ac or dc loads from as little as nanovolts to hundreds of volts. Likewise, the relays can switch currents in the range of nanoamps to hundreds of milliamps. The MOSFET switches are ideal for small signal switching and are primarily suited for dc or audio frequency applications. Siemens offers integrated current limiting on many of its relays. If load current through the relay exceeds the rated value, the relay clamps the current at a predefined value. If the excessive load current persists, the limiting circuit has a foldback feature to minimize relay power dissipation. The current-limit circuit has a multitude of uses. It can be used in telephony to clamp excessive currents emanating from lightning strikes and/ or power-main crosses or in instrumentation and industrial application to squelch transients from reactive loads. The current-limit circuit also provides short-circuit protection in power-feed applications. The SSRs feature a monolithic output die that minimizes wire bonds and permits easy integration of high-performance circuits such as current limiting in normally-open switches. The output die contains all the necessary circuitry to perform a relay function, including the photodiode receptor array, turn-on and turn-off control circuitry, and the MOSFET switches. The optically-coupled input is controlled by a highly efficient GaAlAs infrared LED. Siemens SSRs are available in a 6- or 8-pin through-hole DIP or in gullwing surface-mount packages. Some parts are also offered in 8- or 18-pin small-outline packages (SOPs). The SOPs are size and height compatible with PCMCIA Type 2 cards. A 0.4 mm distance through insulation spacing is also available on “H” suffix coded parts. Refer to the Parts Coding section for a more in-depth description of these parts.
1 of 20
October 1998
Typical Applications • ac Switch • Telephone • Heater Control • Light Control • Switching Systems • Voltmeters • Test Equipment
Application Function Equipment
• • • • • • •
Typical Applications (continued) • Service Equipment • Thermostats • Answering Machines • E&M Signaling • Battery Switch • Multiplexers • Scanners • Board Testers • Gas Pumps • Motor Controls • Output Modules • Appliances
Modems Programmable Controllers FAX Data Acquisition Systems Security Equipment Electric Meters Ring Relay
Application Function
Flying Capacitor Flying Capacitor Switch Data Acquisition Systems Multiplexers Scanners
Equipment LH1522
LH1522
+ –
SENSOR OUTPUT
DATA OUT
Telephone Line Interface/SLIC Ring Relay Break Switch Ground Start Test Access E&M Signalling Subscriber Line Interface Circuits PBX Switching Systems Test/Service Equipment (1/2) LH1524
RING GENERATOR
RING ACCESS TIP
SECONDARY PROTECTOR AT&T LH1150
Application Function Equipment
Ring Generators Square Wave Generator PBX Central Office Equipment Ring Generator
LH1513 BREAK SWITCH
LINE FEED
RING LH1504 GROUND START
RING ACCESS (1/2) LH1524
LH1513
LH1513
dcV
+5 V
Application Function Equipment
20 Hz 2 dcV P-P ac
+5 V
Lamp, Light, Indicator Control ac Switch Programmable Controllers Thermostats Control Panels Industrial Controls
20 Hz
LH1516 +5 V
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
2 of 20
Typical Applications October 1998
Application Function Equipment
Application Function Equipment
Data Access Arrangement (DAA) Current-Limited Switchhook Control Modems Security Equipment Answering Machines Telephones FAX
Thermocouple Switching Thermocouple Matrix Control Scanners Data Acquisition Systems Programmable Controllers
THERMOCOUPLER LH1544
+5 V OFF HOOK LH1525
VM FUSE
ISOLATED CIRCUITRY
TIP
TVS RING
LH1544
RING DETECT
RINGDET
THERMOCOUPLER
Application Function
Multiplexer Analog Signal Multiplexer Analog Input Module Instrumentation Voltmeters Test Equipment Board Testers Scanners Data Acquisition Systems
Equipment
Application Function Equipment
Alarm Switch Glass Break Indicator Fire, Smoke Detector Security Systems Fire/Smoke Alarms
+5 V LOAD
LH1522
LH1510 +5 V
µP
D E C O D E R
LH1522
TO ALARM
SENSOR OUTPUT
LH1522
LH1522
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
3 of 20
Typical Applications October 1998
Application Function
Application Function Equipment
Print Head Driver Current-Limited Drivers Piezoelectric Transducer High-Voltage Print Head Ink Jet Printers Display Drivers Thermal Printers
Equipment
Talk/Data Switch On/Off-hook Control Modems FAX
+5 V
A2 (TIP)
D DATA MANIPULATION AND LOGIC CONTROL
ENABLE
D FLIP-FLOP
Q
LH1536
LH1536 K2
K3
B2 (ASSOCIATED PHONE) (RING) (NORMALLY CLOSED)
PHONE
DELAY
FUSE
A (TIP)
LH1513 K1
LH1520
ISOLATED CIRCUITRY
HIGH VOLTAGE PIEZOELECTRIC TRANSDUCER
+5 V
TVS
B (PHONE LINE) (RING) OFFHOOK RING DETECT RINGDET
Application Function Equipment
Motor, Light, Heat, Solenoid Control Triac Predriver Industrial Controls Programmable Controllers Factory Automation Equipment Appliances
Application Function Equipment
Two-Line PSTN Interface On/Off-hook Control Telephone Equipment Test/Service Equipment
LH1503 TIP
LH1510
LINE 1
TIP
RING
LOAD
+
MOV
TRIAC
LH1503 RING
TIP
– RING
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
4 of 20
LINE 2
Typical Applications October 1998
Wiring Diagrams ac/dc OUTPUT CONFIGURATIONS
SINGLE LOAD 1
6
2
5
1
8
LOAD
LOAD 2 6, 7
NC
NC
SOP
3 3
4
LOAD
5
4
LOAD
TWO LOADS 1
8
2
7
LOAD 1
LOAD 1
SOP 3
6
5
4
LOAD 2
LOAD 2
1
18
LOAD 1
2
17
NC
3
16
NC
4
15
LOAD 1
6
13
7
12
8
11
9
10
LOAD 2 NC NC LOAD 2
dc OUTPUT CONFIGURATIONS SINGLE LOAD — REDUCED RON — INCREASED LOAD CURRENT — REDUNDANCY
1
6
2
5
3
4
+ LOAD
– LOAD
SINGLE LOAD 1
6
2
5
3
4
+ LOAD
– LOAD
1
6
2
5
3
4
– LOAD
+ LOAD
TWO LOADS
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
1
6
2
5
3
4
5 of 20
+ LOAD 1
–LOAD COMMON
+ LOAD 2
Wiiring Diagrams October 1998
LH1500, LH1504 LH1510, LH1516 1 Form A Absolute Maximum Ratings TA=25°C Stresses in excess of the Absolute Maximum Ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to Absolute Maximum Ratings for extended periods of time can adversely affect reliability. Parameter
Symbol
Test Conditions
LH1500
LH1504
LH1510
LH1516
Units
Ambient Operating Temperature range
TA
—
–40 to +85
Storage Temperature Range
Tstg
—
–40 to +150
Pin Soldering Temperature
TS
t=10 s max
260
Input/Output Isolation Voltage*
VISO
—
3750
LED Continuous Forward Current
IF
—
50
mA
LED Reverse Voltage
VR
IR £ 10 mA
8
V
dc or Peak ac Load Voltage
VL
IL £ 50 mA
Continuous dc Load Current Bidirectional Operation Unidirectional Operation
IL
—
Peak Load Current
IP
Output Power Dissipation (continuous)
PDISS
°C
Vrms
350
400
200
400
150 250
95 —
200 350
240 450
t=100 ms (single shot)
†
†
†
†
mA
—
600
600
mW
mA
550
* 5300 Vrms input/output isolation voltage available on some products. Consult factory. † Refer to Current Limit Performance Application Note 58 for a discussion on relay operation during transient currents.
Recommended Operating Conditions 95
IFON = 5 mA to 20 mA
120
LOAD CURRENT (mA)
LOAD CURRENT (mA)
150
90 IFON = 2 mA IFON = 3 mA IFON = 4 mA
60 30
80 60 IFON = 2 mA IFON = 3 mA IFON = 4 mA
40
20 LH1504
LH1500
0 –40
IFON = 5 mA to 20 mA
–20
0
20
40
60
0 –40
80
–20
IFON = 5 mA to 20 mA
160 120 IFON = 2 mA IFON = 3 mA IFON = 4 mA
80 40
LH1510
0 –40
–20
20
40
200
LOAD CURRENT (mA)
LOAD CURRENT (mA)
200
0
60
80
AMBIENT TEMPERATURE (°C)
AMBIENT TEMPERATURE (°C)
IFON = 5 mA to 20 mA
160 120 IFON = 2 mA IFON = 4 mA IFON = 3 mA
80 40
LH1516
0
20
40
60
0 –40
80
AMBIENT TEMPERATURE (°C)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
–20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
6 of 20
October 1998
Electrical Characteristics TA=25°C Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering evaluations. Typical values are for information purposes only and are not part of the testing requirements. .
I N P U T
Parameter
Symbol
Test Conditions
Values
LH1500
LH1504
LH1510
LH1516
Units
LED Forward Current for Switch Turn-on
IFon
IL=100 mA t=10 ms
LED Forward Current for Switch Turn-off
IFoff
LED Forward Voltage
VF
ON-resistance ac/dc Pin 4 (±) to 6 (±) dc Pin 4, 6 (+) to 5 (±)
RON
OFF-resistance
ROFF
IF=0 mA VL=±100 V
ON-state Voltage
—
IL=1 mA
Min Typ Max Min Typ Max ± Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max ± Min Typ Max Min Typ Max Min Typ Max ± Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max
— 1.0 2.0 0.2 0.9 — 300 1.15 1.26 1.45 12 20 25 3.00 5.00 6.25 0.5 5000 — — — — — — — 230 270 370 6 — — — — 0.02 200 — — 1.0 350 — 55 — — 10 — — 0.15 — — 0.8 — — 1.2 2.0 — 0.5 2.0
— 0.5 2.0 0.1 0.4 — 350 1.15 1.26 1.45 12* 23* 34* — — — 0.5 5000 — 1.2 1.4 1.8 3.0 3.6 5.0 150 210 270 11 — — — — 0.02 200 — — 1.0 400 — 2.5 — — 2 — — — — — 0.8 — — 1.6 5.0 — 2.0 5.0
— 1.0 2.0 0.2 0.9 — 150 1.15 1.26 1.45 6 10 15 1.50 2.50 3.75 0.5 5000 — — — — — — — 300 360 450 5 600 720 920
— 0.9 2.0 0.2 0.8 — 350 1.15 1.26 1.45 5 7 10 1.25 2.00 2.50 0.5 2500 — — — — — — — 290 400 550 5 — — — — 0.04 200 — — 1.0 400 — 150 — — 30 — — 0.1 — — 0.8 — — 1.1† 3.0† — 0.8† 3.0†
mA mA mA mA mA mA V V V V W W W W W W GW GW GW V V V V V V mA mA mA V mA mA mA nA nA nA mA mA mA V pF pF pF pF pF pF mV mV mV pF pF pF ms ms ms ms ms ms
VL IF=10 mA
IF=5 mA IL=50 mA IF=5 mA IL=100 mA
IL=90 mA t=10 ms
O U T P U T
Current Limit ac/dc Pin 4 (±) to 6 (±) dc Pin 4, 6 (+) to 5 (±)
ILMT
Off-state Leakage Current
—
IF=5 mA t=5 ms VL IF=5 mA, VL=4 V t=5 ms IF=0 mA VL=±100 V IF=0 mA
Output Capacitance Pin 4 to 6
—
VL IF=0 mA VL=1 V IF=0 mA VL=50 V
T R A N S F E R
Switch Offset
—
IF=5 mA
Input/Output Capacitance
CISO
VISO=1 V
Turn-on Time
ton
IF=5 mA IL=50 mA
Turn-off Time
toff
IF=5 mA IL=50 mA
0.02 200 — — 1.0 200 — 60 — — 15 — — 0.15 — — 0.8 — — 1.0† 2.0† — 0.7† 2.0†
* RON=V (50 mA) – V (20 mA)/30 mA, †IF=10 mA. Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
7 of 20
LH1500, LH1504, LH1510, LH1516 October 1998
LH1517, LH1518, LH1519 1 Form A
Absolute Maximum Ratings TA=25°C Stresses in excess of the Absolute Maximum Ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to Absolute Maximum Ratings for extended periods of time can adversely affect reliability. Parameter
Symbol
Test Conditions
TA
—
Ambient Operating Temperature range Storage Temperature Range
LH1518
Pin Soldering Temperature
TS IF
Units
°C
–40 to +150 t=10 s max
260
—
3750
Vrms
50
mA
VISO
LED Continuous Forward Current
LH1519
–40 to +85
Tstg
Input/Output Isolation Voltage*
LED Reverse Voltage
VR
IR £ 10 mA
dc or Peak ac Load Voltage
VL
IL £ 50 mA
Continuous dc Load Current Bidirectional Operation Unidirectional Operation
IL
Peak Load Current
IP
Output Power Dissipation (continuous)
LH1517
8
V
150
250
—
mA
t=100 ms (single shot) —
PDISS
400 800
155 300
240 450
1200
†
†
600
550
mW
* 5300 Vrms input/output isolation voltage available on some products. Consult factory. † Refer to Current-Limit Performance Application Note for a discussion on relay operation during transient currents.
Recommended Operating Conditions 130 120
IFON = 6 mA to 20 mA
320 240 IFON = 2 mA IFON = 3 mA
160
IFON = 4 mA IFON = 5 mA
80
LH1517
0 –40
80 60
IFON = 2 mA
40
IFON = 3 mA IFON = 4 mA
20 LH1518
–20
0
20
40
60
0 –40
80
AMBIENT TEMPERATURE (°C)
225
LOAD CURRENT (mA)
IFON = 5 mA to 20 mA
100 LOAD CURRENT (mA)
LOAD CURRENT (mA)
400
–20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
IFON = 5 mA to 20 mA
180 135
IFON = 2 mA IFON = 3 mA IFON = 3 mA
90 45
LH1519
0 –40
–20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
8 of 20
October 1998
result of engineering evaluations. Typical values are for information purposes only and are not part of the testing requirements.
Electrical Characteristics TA=25°C Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the
I N P U T
Parameter
Symbol
Test Conditions
LED Forward Current for Switch Turn-on
IFon
IL=100 mA t=10 ms
LED Forward Current for Switch Turn-off
IFoff
LED Forward Voltage
VF
ON-resistance ac/dc Pin 4 (±) to 6 (±) dc Pin 4, 6 (+) to 5 (±)
RON
OFF-resistance
ROFF
IF=0 mA VL=±100 V
ON-state Voltage
—
IL=1 mA
Values
LH1517
LH1518
LH1519
Units
Min Typ Max Min Typ Max ±
— 0.9 2.0 0.2 0.8 — 100
— 0.8 2.0 0.2 0.7 — 200
— 0.9 2.0 0.2 0.8 — 200
mA mA mA mA mA mA V
Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max ±
1.15 1.26 1.45 1 2 3 0.25 0.50 0.85 0.5 2500 — — — — — — — — — — —
1.15 1.26 1.45 10 15 20 2.50 3.75 5.00 0.5 5000 — — — — — — — 170 200 280 6
1.15 1.26 1.45 3 6 10 0.75 1.50 2.50 0.5 2500 — — — — — — — 330 450 550 4
V V V W W W W W W GW GW GW V V V V V V mA mA mA V
Min Typ Max Min Typ Max Min Typ Max ±
— — — — 0.04 200 — — 1.0 150
— — — — 0.02 200 — — 1.0 250
— — — — 0.04 200 — — 1.0
mA mA mA nA nA nA mA mA mA V
Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max
— 185 — — 45 — — 0.1 — — 0.8 — — 1.7† 3.0† — 1.3† 3.0†
— 55 — — 10 — — 0.15 — — 0.8 — — 1.4 3.0 — 0.7 3.0
— 100 — — 20 — — 0.1 — — 0.8 — — 2.0 3.0 — 0.9 3.0
pF pF pF pF pF pF V V V pF pF pF ms ms ms
VL IF=10 mA IF=5 mA IL=50 mA IF=5 mA IL=100 mA
IL=90 mA t=10 ms O U T P U T
Current Limit ac/dc Pin 4 (±) to 6 (±) dc Pin 4, 6 (+) to 5 (±)
ILMT
Off-state Leakage Current
—
IF=5 mA t=5 ms VL IF=5 mA, VL=4 V t=5 ms IF=0 mA VL=±100 V IF=0 mA
Output Capacitance Pin 4 to 6
—
VL IF=0 mA VL=1 V IF=0 mA VL=50 V
T R A N S F E R
Switch Offset
—
IF=5 mA
Input/Output Capacitance
CISO
VISO=1 V
Turn-on Time
ton
IF=5 mA IL=50 mA
Turn-off Time
toff
IF=5 mA IL=50 mA
ms ms
* IF=1.5 mA † IF=10 mA ‡ IL=25 mA Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
9 of 20
LH1517, LH1518, LH1519 October 1998
LH1530, LH1535, LH1540 LH1541, LH1550 1 Form A implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to Absolute Maximum Ratings for extended periods of time can adversely affect reliability.
Absolute Maximum Ratings TA=25°C Stresses in excess of the Absolute Maximum Ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not Parameter Ambient Operating Temperature Range
Symbol
Test Conditions
LH1530
LH1535/ LH1540
LH1541
LH1550
Units
TA
—
–40 to +85
–40 to +85
–40 to +85
–40 to + 85
°C
—
–40 to +150 –40 to +150 –40 to +150 –40 to +150
°C
Storage Temperature Range
Tstg
Pin Soldering Temperature
TS
Input/Output Isolation Voltage*
t=10 s max
260
260
260
260
°C
VISO
—
3750
3750
3750
3750
Vrms
LED Continuous Forward Current
IF
—
50
50
50
50
mA
LED Reverse Voltage
VR
IR £ 10 mA
8
8
8
5
V
dc or Peak ac Load Voltage
VL
IL £ 50 mA
350
400/350
200
350
V
Continuous dc Load Current Bidirectional Operation Unidirectional Operation
IL
— 150 250
120 250
55 —
100 —
mA mA
Peak Load Current
IP
400
†
100
†
mA
550
550
550
550
mW
Output Power Dissipation (continuous)
t=100 ms (single shot) —
PDISS
* 5300 Vrms input/output isolation voltage available on some products. Consult factory. † Refer to Current-Limit Performance Application Note for a discussion on relay operation during transient currents
Recommended Operating Conditions 120
IFON = 5 mA to 20 mA
120
LOAD CURRENT (mA)
LOAD CURRENT (mA)
150
90 IFON = 2 mA IFON = 3 mA IFON = 4 mA
60 30
IFON = 5 mA to 20 mA
100 80 60
IFON = 2 mA IFON = 3 mA IFON = 4 mA
40 20
LH1540 LH15
LH1530
0 –40
–20
0
20
40
60
0 –40
80
–20
100
40
80
LOAD CURRENT (mA)
LOAD CURRENT (mA)
50
30 IFON = 2 mA IFON = 3 mA IFON = 4 mA IFON = 5 mA to 20 mA
10
20
40
60
80
AMBIENT TEMPERATURE (°C)
AMBIENT TEMPERATURE (°C)
20
0
60
IF = 1.5 mA IF = 3.75 mA IF = 4.5 mA 20 TO 20 mA 40
LH1541 0
–40
–20
0
20
40
60
0
80
AMBIENT TEMPERATURE (°C)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
LH1550
–40
–20
0
20
40
60
80
AMBIENT TEMPERATURE (C°)
10 of 20
October 1998
result of engineering evaluations. Typical values are for information purposes only and are not part of the testing requirements.
Electrical Characteristics TA=25°C Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the
I N P U T
Parameter
Symbol
Test Conditions
LED Forward Current for Switch Turn-on
IFon
IL=100 mA t=10 ms
LED Forward Current for Switch Turn-off
IFoff
LED Forward Voltage
VF
ON-resistance ac/dc Pin 4 (±) to 6 (±) dc Pin 4, 6 (+) to 5 (±)
RON
OFF-resistance
ROFF
IF=0 mA VL=±100 V
ON-state Voltage
—
IL=1 mA
Values
LH1530
LH1535/ LH1540
LH1541
LH1550
Units
Min Typ Max Min Typ Max ±
— 1.0 2.0 0.2 0.9 — 300
— 1.0 2.0 0.2 0.9 — 350/300
— 0.6 2.0 0.1 0.5 — 150
— 1.2 2.5 0.01 1.100 — 300
mA mA mA mA mA mA V
Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max ±
1.15 1.26 1.45 12 18 25 3.00 5.00 6.25 0.5 5000 — — — — — — — — — — —
1.15 1.26 1.45 12 20 25 3.00 5.00 6.25 0.5 5000 — — — — — — — 170 210 250 6
1.10* 1.19* 1.45* 70 110 160 — — — 0.5 10000 — — — — — — — — — — —
1.10* 1.19* 1.45* 25‡ 37‡ 50‡ — — — 0.5 5000 — — — — — — — 150 200 270 13
V V V W W W W W W GW GW GW V V V V V V mA mA mA V
Min Typ Max Min Typ Max Min Typ Max ±
— — — — 0.1 200 — — 1.0 350
— — — — 0.32 200 — — 1.0 400/350
— — — — 0.4 200 — — 1.0 200
— — — — 0.3 200 — — 1.0 350
mA mA mA nA nA nA mA mA mA V
Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max Min Typ Max
— 55 — — 10 — — 0.15 — — 0.8 — — 0.5† 1.0† — 0.5† 1†
— 55 — — 10 — — 0.15 — — 0.8 — — 1.2 2.0 — 0.5 2.0
— 4.8 — — 3.6 — — 0.15 — — 0.8 — — 0.12 0.25 — 0.03 0.25
— 40 — — 8 — — 0.15 — — 0.8 — — 1.4 3.0 — 0.5 3.0
pF pF pF pF pF pF V V V pF pF pF ms ms ms ms ms ms
VL IF=10 mA IF=5 mA IL=50 mA IF=5 mA IL=100 mA
IL=90 mA t=10 ms O U T P U T
Current Limit ac/dc Pin 4 (±) to 6 (±) dc Pin 4, 6 (+) to 5 (±)
ILMT
Off-state Leakage Current
—
IF=5 mA t=5 ms VL IF=5 mA, VL=4 V t=5 ms IF=0 mA VL=±100 V IF=0 mA
Output Capacitance Pin 4 to 6
—
VL IF=0 mA VL=1 V IF=0 mA VL = 50 V
T R A N S F E R
Switch Offset
—
IF=5 mA
Input/Output Capacitance
CISO
VISO=1 V
Turn-on Time
ton
IF=5 mA IL=50 mA
Turn-off Time
toff
IF=5 mA IL=50 mA
* IF=5 mA. † IF=10 mA. ‡ IL=100 mA, t=10 ms Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
11 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
A. LED Voltage vs. Temperature
B. LED Dropout Voltage vs. Temperature
1.6
1.20
LED FORWARD VOLTAGE (V)
LED FORWARD VOLTAGE (V)
IL = 100 mA
1.5 IF = 50 mA IF = 20 mA
1.4 1.3 1.2 IF = 1 mA IF = 2 mA
1.1
IF = 5 mA
1.15 TYP.
1.10 MIN.
1.05
1.00
IF = 10 mA
1.0 –40
–20
20
0
40
60
0.95 –40
80
0
–20
40
60
80
AMBIENT TEMPERATURE (°C)
AMBIENT TEMPERATURE (°C)
C. LED Current for Switch Turn-On vs. Temperature
D. LED Current for Switch Turn-On vs. Temperature (LH1541)
100 LED FORWARD CURRENT FOR SWITCH TURN-ON (%) NORMALIZED TO 25 °C
LED FORWARD CURRENT FOR SWITCH TURN-ON (%) NORMALIZED TO 25 °C
20
IL = 100 mA 80 60 40
LH1500, LH1504, LH1510, LH1500, LH1504, LH1516, LH1517, LH1518, LH1510, LH1516, LH1519, LH1525, LH1530, LH1517, LH1518, LH1540
20 0 –20 –40 –60 –40
–20
0
20
40
60
80
160 IL = 50 mA 150 120 90 60 30 0 –30 –60 –40
–20
0
20
40
60
80
AMBIENT TEMPERATURE (°C) AMBIENT TEMPERATURE (°C)
E. Current Limit vs. Temperature F. ON-Resistance vs. Temperature 50
IF = 5 mA t = 5 ms VL = SEE ELEC. CHAR.
30 20
CHANGE IN ON-RESISTANCE (%) NORMALIZED TO 25°C
CHANGE IN CURRENT LIMIT (%) NORMALIZED TO 25 °C
40
10 LH1516, LH1519
0 –10 –20
ALL OTHER CURRENT LIMITED SSRs
–30 –40 –40
–20
0
20
40
60
40 B
A – LH1504, LH1516, LH1518, 20 LH1519 30
A – LH1504, LH1516, LH1518, LH1519 B – LH1500, LH1530, LH1540 C – LH1510, LH1517 D – LH1525, LH1541
A
10 C, D
0 B, D
–10 C
–20 IL = 50 mA –30 A
80
–40 –40
AMBIENT TEMPERATURE (°C)
–20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
12 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
ac/dc ON-RESISTANCE VARIATION (%) NORMALIZED TO DATA SHEET RON SPECIFICATION @ IF = 5 mA
B. Variation in ON-Resistance vs. LED Current (LH1525)
1.5 DATA SHEET RON SPECIFICATION @ IF = 5 mA
ac/dc ON-RESISTANCE VARIATION (%) NORMALIZED TO
A. Variation in ON-Resistance vs. LED Current
IL = 50 mA
A, C, D, E
1.0
A A– – LH1500, LH1500, LH1530,LH1530, LH1540 B – LH1504 LH1535, C – LH1510LH1540 D – LH1518
LH1516, LH1517, LH1519 B E– –LH1504
B
0.5
A
B, C
0
D
E
4
8
12
16
7 6 5 4 3 2 1 0.0
20
1.0
2.0
3.0
4.0
5.0
LED FORWARD CURRENT (mA)
LED FORWARD CURRENT (mA)
C. Switch Capacitance vs. Applied Voltage
D. Switch Capacitance vs. Applied Voltage 200
80 IF = 0 mA TA = 25 °C f = 1 MHz
70
A LH1510 A –– LH1510
50
B – LH1500, LH1518,
B – LH1530, LH1500, LH1540 40 A
30
IF = 0 mA TA = 25 °C f = 1 MHz
160
60
CAPACITANCE (pF)
CAPACITANCE (pF)
8
0
–0.5 0
9
A – LH1517 B – LH1516 C – LH1519
120
A
80
20
B
40
10
C
B 0 0
20
40
60
80
0
100
0
20
APPLIED VOLTAGE (V)
60
40
80
100
APPLIED VOLTAGE (V)
E. Switch Capacitance vs. Applied Voltage (LH1525)
F. Switch Capacitance vs. Applied Voltage (LH1541)
70
6.0
60 50 CAPACITANCE (pF)
CAPACITANCE (pF)
5.0
40 30 20 10 0
0
4.0 3.0 2.0 1.0
20
40
60
80
0.0
100
0
20
30
40
50
60
70
80
90 100
APPLIED VOLTAGE (V)
APPLIED VOLTAGE (V)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
10
13 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
A. Insertion Loss vs. Frequency
B. Insertion Loss vs. Frequency (LH1525)
0.30
0.6
A
RL = 600 W RL = 600 W
0.5 B
INSERTION LOSS (dB)
INSERTION LOSS (dB)
0.25 0.20
0.15
C D LH1530, LH1540 AAB –––LH1500, LH1500, LH1530, LH1518 C – LH1510 LH1540 LH1535, D – LH1516, LH1519
0.10
E – LH1517
0.05
10 3
10 4
0.3 0.2 0.1
E
0 10 2
0.4
0.0 102
10 5
103
FREQUENCY (Hz)
1.75
105
FREQUENCY (Hz)
C. Insertion Loss vs. Frequency (LH1541) 2.00
104
D. Output Isolation 100
RL = 600 W
VP = 10 V RL = 50 W
ISOLATION (dB)
INSERTION LOSS (dB)
80 1.50 1.25 1.00 0.75
60 A A –– LH1504, LH1541 A LH1504, B – LH1500, LH1510, LH1518, C – LH1525, LH1530, LH1540 LH1541
40
B
LH1519 D – LH1516, LH1517
C D
0.50
20 0.25 0 102
103
104
0 102
105
103
FREQUENCY (Hz)
104
105
106
107
FREQUENCY (Hz)
E. Leakage Current vs. Applied Voltage
F. Leakage Current vs. Applied Voltage at Elevated Temperatures
90 80
3.0
OFF-STATE LEAKAGE CURRENT (nA)
OFF-STATE LEAKAGE CURRENT (pA)
100 IF = 0 mA TA = 25 °C
70
LH1516, LH1517, LH1519
60 50 40 30
ALL OTHER FORM A SSRs
20 10 0 0
LH1541 50
100
150
200
250
300
A LH1517, LH1519 A––LH1516, LH1516,
A
85 °C
– LH1500, LH1519 LH1504, LH1510, LH1517, 2.5 B LH1518, LH1530, LH1540
B
2.0 70 °C
1.5
A B
1.0 50 °C
A
0.5
B 0
350 400
0
50
100
150
200
250
300
350
400
LOAD VOLTAGE (V) LOAD VOLTAGE (V)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
14 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
A. Leakage Current vs. Applied Voltage at Elevated Temperatures (LH1525)
B. Leakage Current vs. Applied Voltage at Elevated Temperatures (LH1541) 270 OFF-STATE LEAKAGE CURRENT (pA)
OFF-STATE LEAKAGE CURRENT (nA)
3.5 3.0 85 °C
2.5 2.0 1.5 70 °C 1.0 50 °C
0.5 0.0 0
50
100
150
200
250
300
350 400
240
85 °C
210 180 150 120 70 °C
90 60
50 °C
30 0
LOAD VOLTAGE (V)
0
20
40
80 100 120 140 160 180 200
60
LOAD VOLTAGE (V)
D. Switch Breakdown Voltage vs. Temperature (LH1541)
8 6 4
LH1500, LH1504, LH1510, LH1500, LH1504, LH1516, LH1517, LH1518, LH1510, LH1516, LH1519, LH1525, LH1530, LH1517, LH1518, LH1540
2 0 –2 –4 –6 –8 –40
–20
0
8
CHANGE IN BREAKDOWN VOLTAGE (%) NORMALIZED TO 25 °C
CHANGE IN BREAKDOWN VOLTAGE (%) NORMALIZED TO 25 °C
C. Switch Breakdown Voltage vs. Temperature
20
40
60
6 4 2 0 –2 –4 –6 –8 –10 –40
80
–20
20
40
60
80
AMBIENT TEMPERATURE (°C)
AMBIENT TEMPERATURE (°C)
E. Switch Offset Voltage vs. Temperature
F. Switch Offset Voltage vs. Temperature (LH1525) 5
3.5 LH1510, LH1518, A ––LH1500, A LH1500, LH1530, LH1518, LH1540, LH1541 LH1510, LH1517, LH1519 B – LH1516, LH1535, LH1530,
3.0 2.5
IF = 5 mA
SWITCH OFFSET VOLTAGE (µV)
SWITCH OFFSET VOLTAGE (µV)
0
2.0 1.5 1.0 B A
0.5
IF = 5 mA 4
3
2
1
0
0 20
30
40
50
60
70
80
20
90
AMBIENT TEMPERATURE (°C)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
30
40
50
60
70
80
90
AMBIENT TEMPERATURE (°C)
15 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
A. Switch Offset Voltage vs. LED Current
B. Switch Offset Voltage vs. LED Current (LH1525) 0.6
A LH1510, LH1518, A––LH1500, LH1500,
0.5
SWITCH OFFSET VOLTAGE (µV)
SWITCH OFFSET VOLTAGE (µV)
0.6
LH1530,LH1518, LH1540 LH1510, B – LH1516, LH1517, LH1519
0.4 A 0.3 B
0.2
0.1
0.5 0.4 0.3 0.2 0.1 0.0
0 0
5
15
10
0
25
20
5
LED FORWARD CURRENT (mA)
60
CHANGE IN TURN-ON TIME (%) NORMALIZED TO 25 °C
SWITCH OFFSET VOLTAGE (µV)
0.5 0.4 0.3 0.2
40
A B
30
15
10
20
0 –10 –20
–40 –40
25
C D
CHANGE IN TURN-OFF TIME (%) NORMALIZED TO 25 °C
50 40 30 20 10 0 –10 IF = 5 mA IL = 50 mA
–30 –40 0
20
40
60
80
0
20
40
60
80
160 140
A A –– LH1516, LH1519 B – LH1504 LH1516, C – LH1500, LH1510, LH1517, LH1530, H1519 LH1540
A,B C D
120 100
D – LH1518
80 60 40 20
A
0 –20 –40 –60 –80 –40
IF = 5 mA IL = 50 mA
C, D B
–20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
AMBIENT TEMPERATURE (°C)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
–20
F. Turn-Off Time vs. Temperature
70 60
–20
IF = 5 mA IL = 50 mA
AMBIENT TEMPERATURE (°C)
E. Turn-On Time vs. Temperature (LH1541)
–40
LH1519, LH1530
D C A B
10
LED FORWARD CURRENT (mA)
–20
25
20
–30 0
A A –– LH1500, LH1518, LH1540 B – LH1504 LH1500, C – LH1510, LH1525 D – LH1516, LH1517, LH1518,
50
0.1
5
20
D. Turn-On Time vs. Temperature
0.6
0
15
LED FORWARD CURRENT (mA)
C. Switch Offset Voltage vs. LED Current (LH1541)
CHANGE IN TURN-ON TIME (%) NORMALIZED TO 25 °C
10
16 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
A. Turn-Off Time vs. Temperature (LH1525)
B. Turn-Off Time vs. Temperature (LH1541) 160 140
IF = 5 mA IL = 50 mA
CHANGE IN TURN-OFF TIME (%) NORMALIZED TO 25 °C
CHANGE IN TURN-OFF TIME (%) NORMALIZED TO 25 °C
15 10 5 0 –5 –10
120 100 80 60 40 20 0 –20 –40
IF = 5 mA IL = 50 mA
–60 –15 –40
–20
0
20
40
60
–80 –40
80
–20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
AMBIENT TEMPERATURE (°C)
C. Turn-On Time vs. LED Current (LH1500, LH1518, LH1540)
D. Turn-On Time vs. LED Current (LH1504) 10 IL = 50 mA
10
IL = 50 mA
8 TURN-ON TIME (ms)
TURN-ON TIME (ms)
8 85 °C
6
25 °C –40 °C
4 –40 °C
4 –40 °C 25 °C
2
25 °C
85 °C
2
25 °C 85 °C –40 °C
6
85 °C
0 0
0 0
10
20
30
40
50
10
20
30
40
50
LED FORWARD CURRENT (mA)
LED FORWARD CURRENT (mA)
F. Turn-On Time vs. LED Current (LH1516, LH1519) E. Turn-On Time vs. LED Current (LH1510) 10 10
IL = 50 mA IL = 50 mA
8 TURN-ON TIME (ms)
TURN-ON TIME (ms)
8 –40 °C 6
25 °C 85 °C
4 –40 °C 2
25 °C
6
4
–40 °C 25 °C 85 °C
2
85 °C
0 0
0 0
10
20
30
40
10
20
30
40
50
50
LED FORWARD CURRENT (mA) LED FORWARD CURRENT (mA)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
17 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
A. Turn-On Time vs. LED Current (LH1517)
B. Turn-On Time vs. LED Current (LH1525) 3.0
10 IL = 50 mA
2.4 TURN-ON TIME (ms)
TURN-ON TIME (ms)
8
6 –40 °C 25 °C 85 °C
4
1.8 85 °C 25 °C –40 °C
1.2
0.6
2
0.0
0 0
10
20
30
40
0
50
8
12
20
16
LED FORWARD CURRENT (mA)
LED FORWARD CURRENT (mA)
C. Turn-On Time vs. LED Current (LH1530)
D. Turn-On Time vs. LED Current (LH1541)
10
1.50
IL = 50 mA
1.25
TURN-ON TIME (ms)
8
TURN-ON TIME (ms)
4
6
4 –40 °C 25 °C 85 °C
2
10
20
1.00
+25 °C
0.75
–40 °C
0.50
0.25
0 0
+85 °C
30
40
0
50
0
5
10
15
20
LED FORWARD CURRENT (mA)
LED FORWARD CURRENT (mA)
E. Turn-Off Time vs. LED Current (LH1500, LH1530, LH1540)
F. Turn-Off Time vs. LED Current (LH1504) 4.5
0.9
–40 °C
IL = 50 mA
–40 °C
4.0 IL = 50 mA
TURN-OFF TIME (ms)
TURN-OFF TIME (ms)
0.8 0.7 0.6 0.5
25 °C
0.4
85 °C
3.5 3.0 2.5 25 °C
2.0 1.5
85 °C
1.0
0.3 0.5
0.2 0
10
20
30
40
0
10
20
30
40
50
50 LED FORWARD CURRENT (mA)
LED FORWARD CURRENT (mA)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
18 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
A. Turn-Off Time vs. LED Current (LH1510, LH1518) 1.4
1.6
IL = 50 mA
– 4 0 °C
–40 °C
1.4 TURN-OFF TIME (ms)
1.2 TURN-OFF TIME (ms)
B. Turn-Off Time vs. LED Current (LH1516, LH1519)
1.0
0.8 25 °C 0.6 85 °C
0.4
10
20
30
1.2 1 25 °C
0.8 0.6
0.2 0
IL = 50 mA
40
85 °C
0.4
50
0
LED FORWARD CURRENT (mA)
10
20
30
40
50
LED FORWARD CURRENT (mA)
C. Turn-Off Time vs. LED Current (LH1517)
D. Turn-Off Time vs. LED Current (LH1525)
2.5
0.32
–40 °C
85 °C 0.29
IL = 50 mA 1.5
TURN-OFF TIME (ms)
TURN-OFF TIME (ms)
2.0
25 °C
1.0
85 °C
25 °C
0.26
0.23
–40 °C
0.20
0.5
0.17
0 0
10
20
30
40
0
50
LED FORWARD CURRENT (mA)
4
8
12
16
20
LED FORWARD CURRENT (mA)
E. Turn-Off Time vs. LED Current (LH1541) 40 –40 °C TURN-OFF TIME (µs)
30 +85 °C +25 °C
20
10
0 0
10
20
30
40
50
LED FORWARD CURRENT (mA)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
19 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998
Typical Performance Characteristics, LH1550 B. LED Current for Switch Turn-On/Off vs. Temperature
A. LED Voltage vs. Temperature
1.5
LED FORWAD CURRENT FOR SWITCH TURN-0N/OFF (%) NORMALIZED TO 25 °C
LED FORWAD VOLTAGE (V)
1.6
IF = 50 mA IF = 20 mA
1.4 1.3 1.2 1.1
IF = 1 mA IF = 2 mA
1.0 –40
IF = 5 mA IF = 10 mA –20
0 20 40 60 AMBIENT TEMPERATURE, TA (°C)
80
300 IF = 50 mA 200
100
0
–100 –40
CHANGE IN ON-RESISTANCE (%) NORMALIZED TO 25 °C
CHANGE IN CURRENT LIMIT (%) NORMALIZED TO 25 °C
40
60
80
60 IF = 5 mA, t = 5 ms
30 20 10 0 –10 –20 –30 –20
0
20
40
60
50 IL = 5 mA 40 30 20 10 0 –10 –20 –30 –40 –40
80
–20
0
20
40
60
80
AMBIENT TEMPERATURE, TA (°C)
AMBIENT TEMPERATURE, TA (°C)
F. Turn-Off Time vs. Temperature
E. Turn-Off Time vs. Temperature 70
80 IF = 5 mA IF = 50 mA
50 40 30 20 10 0 –10 –20 –30 –20
0
20
IF = 5 MA IL = 50 MA
75 CHANGE IN TURN-OFF TIME (%) NORMALIZED TO 25 °C
60 CHANGE IN TURN-ON TIME (%) NORMALIZED TO 25 °C
20
D. ON-Resistance vs. Temperature
40
–40 –40
0
AMBIENT TEMPERATURE, TA (°C)
C. Current Limit vs. Temperature
–40 –40
–20
40
60
25
0
–25
–50 –40
80
–20
0
20
40
60
80
AMBIENT TEMPERATURE, TA (°C)
AMBIENT TEMPERATURE, TA (°C)
Siemens Microelectronics, Inc. • Optoelectronics Division www.smi.siemens.com/opto/
50
20 of 20
LH1530, LH1535, LH1540, LH1541, LH1550 October 1998