Preview only show first 10 pages with watermark. For full document please download

Liebert Gxt Ups - Puerto Rico Suppliers .com

   EMBED


Share

Transcript

Liebert GXT is featured in these Scenarios: Liebert GXT UPS Scenario B 1-2 Racks Single Phase page 10 Scenario C 3-6 Racks Single Phase page 12 Liebert GXT UPS leads the industry in combining the best total cost of ownership with small size, high capacity and function-rich features. This true online UPS offers internal batteries, unlimited extended external batteries, and internal bypass capability, resulting in continuous uptime for the connected equipment. Designed for rack-mount or tower modes, the Liebert GXT is available in 500, 700, 1,000, 1,500, 2,000, 3,000, 6,000, and 10,000 VA ratings, in both 120V and 230V models. Features & Benefits Flexibility: Higher Availability: Lowest Total Cost Of Ownership: n Unit can be installed in either rack or tower configuration. n Protection and conditioning against all forms of power anomalies. n n The Liebert GXT automatically detects and matches line input frequencies of either 60 or 50 Hz. n Internal automatic and manual bypass assure continuity of power to critical loads during system maintenance or in case of internal fault. Corrects for frequency variations without switching to battery, resulting in longer battery life. n Two-year, no-hassle replacement warranty with paid shipping both ways. n Compatible with backup generator — handles frequency variations and other power fluctuations that occur during generator operation. n Configuration program allows selection of UPS features including output voltage, auto-restart enable/disable, and other features. n Wide input voltage window allows the UPS to support the critical load without having to transfer to battery, extending system availability for when battery backup is truly needed. n User-replaceable hot-swappable internal batteries. n Advanced early warning of UPS status via automatic and manual battery test feature. Frequently Asked Questions Question Resolution Why should I consider using online, double-conversion UPS technology? While line interactive UPS technology is appropriate for many situations, there may be times when you need greater power capacity or higher levels of availability offered by online double-conversion technology. With zero transfer time when switching to battery, online technology’s clean power (through 100% power conditioning) causes less stress on power supplies, creating the highest level of equipment protection. Over time, the online, double-conversion Liebert GXT also offers an attractive total cost of ownership. Because an online system corrects for frequency variations without switching to battery, it can greatly extend the lifetime of the UPS battery. Is the Liebert GXT compatible with a backup generator? Generators do not provide computer grade AC power required by today’s sensitive electronics. A true online UPS such as the Liebert GXT will work with a generator and provide tight voltage and frequency regulation. The UPS will bridge the gap between loss of AC power and the time it takes your generator to come up to speed and your loads to be switched to generator power — can your business-critical applications be without power for even a few minutes? How fast can I get a Liebert GXT shipped to my customer? Liebert maintains a warehouse of products for quick distribution. Ingram Micro and Tech Data also stock many standard Liebert UPS products for next day shipment. 38 Competitive Comparison The Liebert GXT offers a number of advantages over the competition, which you can use to generate new high-margin sales. Feature Liebert GXT APC SmartUPS-RT Powerware 9125 Tripplite Smart Online Capacity range down to 500VA. Yes No No No Widest input frequency window (40-70Hz). Yes No No No Delivered fully assembled — batteries connected and activated at the factory. Yes No No Yes Standard rack ears and tower pedestal. Yes No No Yes Two-year, no hassle replacement warranty. Yes No No No Liebert GXT Product Ancillary Guide Liebert GXT UPS GXT2-500RT120 GXT2-700RT120 GXT2-1000RT120 GXT2-1500RT120 GXT2-2000RT120 VA/Watts 500/350W 700/490W 1000/700W 1500/1050W 2000/1400W UPS Battery Kit internal internal internal internal internal External Battery Cabinet GXT2-48VBATT GXT2-48VBATT GXT2-48VBATT GXT2-48VBATT GXT2-48VBATT 4-Post Rack Mounting Kit RMKIT18-32 RMKIT18-32 RMKIT18-32 RMKIT18-32 RMKIT18-32 Web/SNMP Card IS-WEBCARD IS-WEBCARD IS-WEBCARD IS-WEBCARD IS-WEBCARD MicroPOD MP2-115A MP2-115A MP2-115A MP2-115A MP2-120C Liebert GXT UPS GXT2-3000RT120 GXT2-2700RT208 GXT2-6000RTL630 GXT2-6000RT208 VA/Watts 3000/2100W 2700/890W 6000/4200W 6000/4200W 10000/8000W UPS Battery internal internal GXT2-240BATKIT [1] √ GXT2-144BATKIT [1] √ GXT2-288RTBKIT [2] √ External Battery Cabinet GXT2-72VBATT GXT2-72VBATT GXT2-240VBATTUL GXT2-144VBATT GXT2-288RTVBATT 4-Post Rack Mounting Kit RMKIT18-32 RMKIT18-32 RMKIT18-32 RMKIT18-32 RMKIT18-32 Web/SNMP Card IS-WEBCARD IS-WEBCARD IS-WEBCARD IS-WEBCARD IS-WEBCARD MicroPOD MP2-130C MP2-220N PD-L630 √ PD-002 PD-101 GXT2-10000RT208 √ Required UPS Components 39 Liebert GXT UPS Specifications Model Number GXT2-500RT120 GXT2-700RT120 GXT2-1000RT120 Model Rating VA/W 500VA/350W 700VA/ 490W 1000VA / 700W 1500VA / 1050W Dimensions: in (mm) 3.5 x 21.5 x 17 in. 3.5 x 21.5 x 17 in. 3.5 x 21.5 x 17 in. 3.5 x 21.5 x 17 in. (89 x 546 x 432 mm) (89 x 546 x 432 mm) (89 x 546 x 432 mm) (89 x 546 x 432 mm) 49 lbs. (22 kg) 49 lbs. (22 kg) 50 lbs. (23 kg) 51 lbs. (23 kg) WxDxH Weight: lbs. (kg) GXT2-1500RT120 Input AC Parameters Voltage Range 120 VAC nominal, (60 to 140VAC Variable based upon output load) Frequency 40 - 70 Hz; Auto Sensing Input Power Cord 6 ft. attached, w/ NEMA 6 ft. attached, w/ NEMA 10 ft. attached, w/ NEMA 10 ft. attached, w/ NEMA 5-15 plug 5-15 plug 5-15 plug 5-15 plug (6) NEMA 5-15R (6) NEMA 5-15R (6) NEMA 5-15R (6) NEMA 5-15R Output AC Parameters Output Receptacles Voltage 100/110/115/120/127 (user configurable) VAC; ±3% Frequency 50 Hz or 60 Hz Waveform Sinewave Typical Battery Backup Time Full Load 28 minutes 17 minutes 11 minutes 7 minutes Half Load 66 minutes 44 minutes 25 minutes 20 minutes Recharge Time 5 Hours to 95% capacity after full discharge into 100% load Agency Safety UL 1778; c-UL Listed RFI/EMI FCC Part 15, Subpart B, Class A Surge Immunity IEEE 587 Category A & B Transportation ISTA Procedure 1A Model Number GXT2-2000RT120 GXT2-2700RT208 Model Rating VA/W 2000VA / 1400W 2700VA/1890W 3000VA / 2100W Dimensions: in (mm) 3.5 x 21.5 x 17 in. 3.5 x 24.2 x 17 in. 3.5 x 24.2 x 17 in. (89 x 546 x 432 mm) (89 x 615 x 432 mm) (89 x 615 x 432 mm) 54 lbs. (24kg) 75.2 (34.1) 69 lbs. (31kg) WxDxH Weight: lbs. (kg) GXT2-3000RT120 Input AC Parameters Voltage Range 120 VAC nominal, 208 VAC nominal, 120 VAC nominal, (60 to 140VAC Variable based upon output load) (119 to 280VAC Variable based upon output load) (60 to 140VAC Variable based upon output load) Frequency 40 - 70 Hz; Auto Sensing 40 - 70 Hz; Auto Sensing 40 - 70 Hz; Auto Sensing Input Power Cord 10 ft. attached, w/ NEMA 10 ft. attached w/ NEMA L6-20 plug 10 ft. attached, w/ NEMA 5-20 plug 5-15 plug L5-30 plug (6) 5-20 T-Slot (2) NEMA L6-15R (6) NEMA 5-15R receptacles (1) NEMA L6-20R (1) NEMA L5-30R on 12” cord Output AC Parameters Output Receptacles 100/110/115/120/127 (user configurable) VAC; ±3% 200/208/220/230/240 (user configurable) VAC; ±3% 100/110/115/120/127 (user configurable) VAC; ±3% Frequency 50 Hz or 60 Hz 50 Hz or 60 Hz 50 Hz or 60 Hz Waveform Sinewave Sinewave Sinewave Voltage Typical Battery Backup Time Full Load 6 minutes 5 minutes 5 minutes Half Load 14 minutes 16 minutes 16 minutes Recharge Time 5 Hours to 95% capacity after full discharge into 100% load Agency Safety UL 1778; c-UL Listed RFI/EMI FCC Part 15, Subpart B, Class A Surge Immunity IEEE 587 Category A & B Transportation ISTA Procedure 1A 40 Specifications Model Number Model Rating DIMENSIONS Unit W x D x H in. (mm) WEIGHT lbs (kg) Unit GXT2-6000RT208 GXT2-10000RT208 4200W/5200VA at 120/208 (120 or 240 degrees) 8000W/8660VA at 120/208 (120 or 240 degrees) 4200W/6000VA at 120/240 (180 degrees) 8000W/10000VA at 120/240 (180 degrees) 6.9 x 24.2 x 16.9 (176 x 615 x 430) 10.5 x 26.0 x 16.9 (267 x 660 x 430) 67 (30.3) 109 (49.3) Input AC Parameters Nominal Operating Frequency 50 or 60 Hz (Factory Default = 60) Factory Default VAC 120/208 VAC at 120 degrees L1-L2 Factory Default Input Phase Angle Allowable Input Phase Angle 120 degrees 120, 180, 240 degrees, Auto-sensing on application of AC (Restrictions for L-N voltages other than 120 VAC) Factory Default L1-N, L2-N VAC 120 VAC nominal Input Frequency w/o Battery Operation 40 - 70 Hz Output AC Parameters Factory Default VAC 120/208 VAC @ 120 degrees L1-L2 Factory Default Output Phase Angle Allowable Output Phase Angle 120 degrees 120, 180, 240 degrees Auto-sensing on initial application of input AC Factory Default L1-N, L2-N VAC 120 VAC nominal User Configurable L1-N, L2-N VAC 100/110/115/120/127 VAC, ±3% Frequency 50 Hz or 60 Hz, Nominal Waveform Overload Rating Sinewave 200% for 8 cycles; 130% for 10 seconds 200% for 8 cycles then shutdown; 130% for 60 seconds with transfer to bypass with transfer to bypass Environmental Operating Temp +32°F to +104°F (0°C to +40°C) Storage Temp +5°F to +122°F (-15°C to +50°C) Relative Humidity Operating Elevation 0% to 95%, non-condensing Up to 10,000 ft. (3000m) at 104°F (40°C) without derating Storage Elevation Audible Noise 50,000 ft. (15,000 m) maximum <55 dBA, at 1 meter from the rear; <50 dBA, at 1 meter from the front or sides Agency Safety UL 1778, c-UL Listed (Suitable for computer room applications) RFI/EMI FCC Part 15, Subpart B, Class A Surge Immunity IEEE/ANSI C62.41 Category A & B Transportation ISTA Procedure 1A Internal Battery Model Number GXT2-144BATKIT (one required) GXT2-288RTBKIT (two required) WEIGHT lbs (kg) 79 (35.8) (one required) 78.1 (35.5) (two required) Type Quantity x V x Rating Valve-regulated, non-spillable, flame retardant, lead acid 12 x 12V x 9.0 AH (one required) Battery Mfg / Part # Recharge Time 12 x 12V x 9.0 AH (two required) Yuasa / REW 45-12 FR 6 Hours to 90% capacity after full discharge into 100% load Optional Extended Battery Cabinet Model Number DIMENSIONS W x D x H in.(mm) WEIGHT lbs (kg) Unit GXT2-144VBATT GXT2-288RTVBATT (requires two GXT2-288RTBKIT) 3.5 x 24.2 x 16.9 (87 x 618 x 430) 7.0 x 26.0 x 16.9 (178 x 660 x 430) 93.6 (42.5) 41.6 (18.9) (two required) BATTERY PARAMETERS Type Qty x V x Rating Battery Mfg / Part # Valve-regulated, non-spillable, flame retardant, lead acid 12 x 12V x 9.0 AH per kit 12 x 12V x 9.0 AH per kit (two required) Yuasa / REW 45-12 FR ENVIRONMENTAL Operating Temp +32°F to +104°F (0°C to +40°C) Storage Temp +5°F to +122°F (-15°C to +50°C) Relative Humidity Operating Elevation Storage Elevation 0% to 95%, non-condensing Up to 10,000 ft. (3000m) at 104°F (40°C) without derating 50,000 ft. (15,000m) maximum AGENCY Safety UL 1778, c-UL Listed (Suitable for computer room applications) RFI/EMI FCC Part 15, Subpart B, Class A Transportation ISTA Procedure 1A Note: Part Numbers GXT2-6000RT208 and GXT2-10000RT208 do not include internal battery kits. When calculating total unit weight, add weight of internal batteries. 41 Liebert GXT UPS Specifications POWER DISTRIBUTION GXT 2-6000RT208 Model Number PD-HDWR PD-HDWR-MBS PD-001 Amp Rating 30 No Bypass 30 With Bypass 30 With Bypass Input Power Connection Hardwire Terminals Hardwire Terminals L14-30P PD-002 PD-003 30 With Bypass 30 With Bypass L14-30P L14-30P PD-004 PD-005 30 With Bypass 30 With Bypass L14-30P L14-30P PD-006 PD-007 GXT 2-6000RTL630 Model Number PD-L630 GXT 2-10000RT208 Model Number PD-101 PD-102 PD-103 PD-104 PD-105 30 With Bypass 30 With Bypass L14-30P L14-30P Output Power Connection Hardwire Terminals Hardwire Terminals (1) L6-30R,(1) L14-30R, (4) 5-15/20R T-slot (2) L6-20R, (2) 5-15/20R T-slot (2) L6-30R, (4) 5-15/20R T-slot (4) EN60320 / C19 (4) L5-20R, (2) L5-30R (4) L5-20R, (2) L6-30R (4) L6-20R Amp Rating 30 Input Power Connection L6-30P Output Power Connection (2) L6-30R, (2) L6-20R Amp Rating 50 50 50 50 50 Input Power Connection Hard Wired Hard Wired Hard Wired Hard Wired Hard Wired Output Power Connection (8) 5-15/20R T-slot, (2) L6-30R (4) 5-15/20R T-slot, (4) L6-20R (4) 5-15/20R T-slot, (4) L6-30R (4) 5-20R T-slot, (2) L6-30R, (2) L6-20R (4) 5-20R T-slot, (2) L6-30R, (2) L5-20R BATTERY CABINETS UPS Model GXT2-500RT120 GXT2-700RT120 GXT2-1000RT120 GXT2-1500RT120 GXT2-2000RT120 GXT2-3000RT120 GXT2-2700RT208 GXT2-6000RTL630 GXT2-6000RT208 GXT2-10000RT208 Total Runtime with Internal and Extended Battery Cabinets/Full Load Runtime with Internal Extended Battery Batteries @ Full Load Cabinet P/N 28 minutes GXT2-48VBATT 17 minutes GXT2-48VBATT 11 minutes GXT2-48VBATT 7 minutes GXT2-48VBATT 6 minutes GXT2-48VBATT 5 minutes GXT2-72VBATT 5 minutes GXT2-72VBATT 7 minutes GXT2-240VBATTUL 5 minutes GXT2-144VBATT GXT2-288VBATT 6 minutes PARALLEL CAPABILITY GXT2-10000RT208 Model GXT2-PP20KRT208 Voltage 48 VDC 48 VDC 48 VDC 48 VDC 48 VDC 72 VDC 72 VDC 240 VDC 144 VDC 288 VDC One Cabinet 115 min. 68 min. 44 min. 28 min. 18 min. 20 min. 20 min. 21 min. 14 min. 17 min. Two Cabinets 231 min. 136 min. 88 min. 56 min. 42 min. 40 min. 40 min. 38 min. 25 min. 28 min. Description Paralleling POD maximum (3) GXT2-10000RT208 connection for 20kVA capacity plus 10kVA redundancy (requires (1) paralleling cable p/n GXT2-20KPC-6 for connection to each GXT2-10000RT208) GXT2-20KPC-6 Paralleling cable, approximately 6 feet long SYSTEM CONFIGURATION Capacity / Redundancy GXT2-10000RT208 GXT2-288RTBKIT GXT2-PP20KRT208 GXT2-20KPC-6 PD-201 10kVA / 10kVA 2* 4* 1* 2* 1 20kVA / 2* 4* 1* 2* 1 3* 6* 1* 3* 1 20kVA / 10kVA * Required Paralleling Components 42 Liebert GXT Related Products Rack-Mounting Kits These kits are required to mount a Liebert GXT and external battery cabinets within equipment racks. Liebert MicroPOD™ A maintenance bypass switch that permits scheduled maintenance or UPS replacement without discontinuing power to critical equipment. Liebert Nform A simple to use monitoring and communications softwaresolution that combines network monitoring of power and cooling equipment. Liebert MultiLink Shutdown Software Monitors battery status and warns users of impending power loss and automatically shuts down systems in a safe and orderly manner. Extended Warranties One-year and three-year warranty extensions are available at the time of the UPS sale to cost-effectively extend the life of the UPS. 5-Year Power Assurance Package For UPSs 1000VA and larger, 5-year warranty, onsite service, and equipment disposal. For UPSs 6kVA and larger, also includes startup and preventive maintenance. Liebert IntelliSlot Web Card The Liebert IntelliSlot Web Card delivers SNMP and web management communications capability to a Liebert GXT unit. TM 43