LIEBERT® PSI-XR High Performance Rack & Tower UPS For Network Power Protection
Liebert® PSI-XR is a compact, line-interactive UPS system designed especially for IT applications such as network closets and small data centers The flexible design of Liebert PSI-XR allows the unit to be configured as a self-standing tower or to be rack-mounted within a 2U space. It is available in four capacities, in both 230V or 120V models. The UPS features an innovative lineinteractive design incorporating buck/ boost automatic voltage regulation technology. This protects against utility voltage fluctuation by raising and lowering utility power to the level needed by the connected equipment. It also allows the UPS to prolong battery life by maximizing its time on utility power before going to battery.
Liebert PSI-XR Standard Features: Flexibility: yySix to seven battery-backed outlets yyConfigurable input voltage window yyRotatable Display Panel yyAutomatic Frequency Sensing yyMultiple Communications Options (USB, SNMP and Contact Closure).
Higher Availability:
Ideally suited for:
yyData line surge protection yyAdvance early warning of UPS systemstatus yyFull sequenced battery testing yyLightning and surge protection yyRemote emergency power off yyUser replaceable hot swappable batteries yyAmple battery backup time at full load when utility fails, for an orderly shutdown of connected equipment.
yyPC’s yyNetwork workstations yyServers yyNetwork closets yyLarge network peripherals yyVoIP.
Lowest Total Cost Of Ownership: yy0.9 Output Power Factor to provide more power for your protected load, and more energy efficient operation yyWider input voltage window yyReduced installation time and costs yyTwo-Year Warranty Standard.
Liebert PSI XR 2U Rack version
Liebert PSI XR 2U Tower version
LIEBERT® PSI-XR
Liebert® PSI XR Specifications MODEL NUMBER
PS1000RT3-230XR
PS1500RT3-230XR
PS2200RT3-230XR
PS3000RT3-230XR
Power Rating, VA/W
1000VA/900W
1500VA/1350W
2200VA/1980W
3000VA/2700W
440 x 490.5 x 88 560 x 612 x 228
440 x 490.5 x 88 560 x 612 x 228
440 x 700.5 x 88 560 x 821 x 228
440 x 700.5 x 88 560 x 821 x 228
25/29
28/32
42/47
46/51
DIMENSIONS, W X D X H, MM Unit Shipping
WEIGHT, KG Unit / Shipping
INPUT AC PARAMETERS Surge Protection Voltage Range Without Battery Operation Frequency Range Input Socket
IEC-320-C14
Output Sockets
(6) IEC-320-C13
Voltage (Normal Mode) Voltage (Battery Mode) Transfer Time On-Battery Waveform Overload Warning
220J 165 to 300 VAC (configurable) 45~65Hz, (±0.5Hz) IEC-320-C14 IEC-320-C20 (6) IEC-320-C13 (6) IEC-320-C13 (1) IEC-320-C19 220/230/240 VAC (configurable) 220/230/240 VAC (configurable); ±5% before low-battery warning 4-6 ms typical Sinewave >100%
IEC-320-C20 (6) IEC-320-C13 (1) IEC-320-C19
BATTERY PARAMETERS Type Quantity x Voltage x Rating Recharge Time Battery Backup Time
Valve-regulated, nonspillable, lead acid 4 x 12 x 9 8 x 12 x 7.2 5 hours to 90% of rated capacity, after full discharge into resistive load
4 x 12 x 7.2
8 x 12 x 9
ENVIRONMENTAL Operating / Storage Temperature, °C Relative Humidity Operating Altitude Audible Noise
0 to 40 / -15 to 40 0% to 90%, non-condensing Up to 3000m at 35°C without derating <40 dBA, internal fan(s) Off; <45 dBA, internal fan(s) On
AGENCY Safety EMC Transportation Warranty
IEC62040-1-1 IEC/EN/AS 62040-2 2nd Ed Class A ISTA Procedure 1A Certification 2 years standard (+ 1 year warranty extension available) User Manual on CD, Software CD, DB9 Serial cable, USB Cable, Tower Stands, Rack Handles w/ mounting hardware, Safety Instruction Sheet, Environment protection sheet, REPO mate socket, (2) IEC output cables for 1000/1500VA and (3) IEC output cables for 2200/3000 VA, for PS2200/3000: (1) “Shucko” CEE 7/7 to IEC-320-C19 input cord and(1) UK plug to IEC-320-C19 input cord.
Packaging
Liebert PSI XR Battery Cabinet Specifications MODEL NUMBER
PSRT3-24VBXR
Used w/UPS Model
PSRT3-48VBXR
PS1000RT3-230XR / PS1500RT3-230XR
PS2200RT3-230XR / PS3000RT3-230XR
DIMENSIONS, W XD X H, MM Unit / Shipping
440 x 490.5 x 88 / 560 x 675 x 228
WEIGHT, KG Unit / Shipping
29 / 33
BATTERIES Type Quantity x Voltage x Rating Battery Manufacturers
Valve-regulated, nonspillable, lead acid 8 x 12 x 7.2
8 x 12 x 7.2 CSB, YUASA or Equivalent
ENVIRONMENTAL Operating / Storage Temperature, °C Relative Humidity Maximum Operating Altitude
0 to 40 / -15 to 40 0% to 90%, non-condensing 3000m at 35°C without derating
AGENCY
IEC/EN/AS 62040-1-1 / IEC/EN/AS 62040-2 2nd Ed Class A ISTA Procedure 1A Certification
Safety / Emissions Transportation
Battery Runtime Chart (Runtimes are in minutes, assuming fully charged batteries at 25°C) NUMBER OF BATTERIES
PS1000RT3-230XR
Internal Battery (half/full load) 1 Cabinet (half/full load) 2 Cabinet (half/full load) 3 Cabinet (half/full load) 4 Cabinet (half/full load) 5 Cabinet (half/full load) 6 Cabinet (half/full load)
(DB-9) Port
Vertiv Intellislot Port
Emergency Power off USB Connector Port Voltage Configuration DIP Switch
15 / 6 73 / 31 129 / 65 181 / 96 233 / 124 285 / 151 336 / 179
Battery backed-up receptacle 16A
PS1500RT3-230XR
PS2200RT3-230XR
PS3000RT3-230XR
13 / 5 55 / 18 95 / 46 131 / 64 167 / 82 203 / 106 239 / 124
14 / 5 45 / 15 67 / 29 95 / 48 143 / 72 167 / 84 191 / 102
13 / 5 31 / 12 56 / 18 73 / 31 95 / 47 113 / 56 131 / 65
Resettable Input/Output Circuit Breakers
Input Plug Battery Data-Line Backed-up Protection Extended Battery Receptacles 10A Connector
Tech Support Always On! Our Commitment to your daily Business, provided by multi language Tech Support. Toll-free 0080011554499 Toll +39 02 98250222
[email protected]
VertivCo.com | Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827 © 2016 Vertiv Co. All rights reserved. Vertiv™, the Vertiv logo and Liebert® PSI-XR are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.
MKA4L0UKPSIXR - Rev.1-09/2012