CONTROL BOARD REPLACEMENT KIT K1A6426-2 To reduce the risk of SEVERE INJURY or DEATH: • Disconnect ALL electric and battery power BEFORE performing ANY service or maintenance. • Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing gate. • Too much force on gate will interfere with proper operation of safety reversal system. • NEVER increase force beyond minimum amount required to close gate. • NEVER use force adjustments to compensate for a binding or sticking gate. • If one control (force or travel limits) is adjusted, the other control may also need adjustment. • After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST reverse on contact with a rigid object. • READ AND FOLLOW ALL INSTRUCTIONS. • ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with local electrical codes. NOTE: The operator should be on a separate fused line of adequate capacity. • NEVER let children operate or play with gate controls. Keep the remote control away from children. • ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. • Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH. • Activate gate ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to gate travel.
INSTALLATION Before installing the new control board, be sure to note the locations of all terminal block connections. After installing the new control board, the limits, force adjustments and remote controls will have to be reprogrammed.
1 Disconnect all electric power to the operator. 2 Remove the cover and dust guard from the operator. 3 Disconnect the battery.
Cover
the coaxial cable and all terminal block connections 4 Disconnect from the control board.
5 Remove the mounting screws from the control board. 6 Remove the control board.
Coaxial Cable
Copy all settings from the existing control board to the new control board
7 (Force, Timer-To-Close, Bipart Delay, and Auto Open Jumper).
8 Install the new control board with the mounting screws. 9 Reconnect all terminal block connections and the coaxial cable. 10 Reconnect the battery. 11 Reconnect power to the operator.
Terminal Blocks
Terminal Blocks
all other inputs and outputs as necessary (photoelectric sensors, 12 Verify edges, loops, locks, alarm, reset, accessory power, open and single button). CHGR OVLD
Connector
Dust Guard CTRL
AC PWR /SOLAR
Battery Plug
Battery
Transformer or Solar Panel
1
ADJUSTMENT LEARN LIMIT ASSEMBLY The limits are internal settings that indicate when the gate is in the fully open position and the fully closed position. For proper functionality, the limits must be programmed during the installation process. The gate has to travel a minimum of 6 feet in order to program the limits. The programming uses a combination of buttons on the control board. The specific buttons used for programming depends on which side of the gate the primary operator is installed and how many operators the installation includes. BEFORE programming the limits ensure that the gate is closed and the chain is connected to the operator. To close the gate press the reset switch to RESET/DISCONNECT, then manually close the gate. To resume normal operation press the reset switch back to NORMAL OPERATION. SINGLE GATE LEFT-HAND SIDE
1 2
1
Close the gate.
GATE A 1
PrOut op sid er e ty
Press and release the LEARN LIMITS button. The SET OPEN LIMIT LED will blink.
SET N OPEN LIMIT
SET CLOSE LIMIT
PROGRAM OPEN
GATE 2 G
4
ey t id r s e In op r
P
3
Press and hold the GATE 1 right button to move the gate to the desired OPEN position. When the gate is in the desired position, release the button. NOTE: The Gate 1 right and left buttons can be used to jog the gate back and forth as needed. When the gate is in the desired OPEN position, press and release the LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS LED will blink.
3
2
6
4
GATE 1 Right Button
LEARN LIMITS Button
LEARN LIMITS Button
DIAGNOSTIC
GATE A 1
SET OPEN LIMIT
GATE 1
PROGRAM CLOSE
5
LEARN LIMITS
SET CLOSE
Press and hold the GATE 1 left button to move the gate to the desired CLOSED position. When the gate is in the desired position, release the button. NOTE: The Gate 1 right and left buttons can be used to jog the gate back and forth as needed. When gate is in the desired CLOSED position, press the LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS LED will stop blinking.
5
SET CLOSE LIMIT
EP"
E
"B
LEARN LIMITS
GATE 2 G
6 LEARN LIMITS Button
GATE 1 Left Button DIAGNOSTIC
GATE A 1
SET OPEN LIMIT
GATE 1
Programming is now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming or refer to the following page.) Test the limits by pressing the SINGLE BUTTON to open and close the gate.
SET CLOSE
SET CLOSE LIMIT
"
EEP
"B
LEARN LIMITS
GATE 2 G
SINGLE GATE RIGHT-HAND SIDE
1 2
Close the gate.
1
Press and release the LEARN LIMITS button. The SET OPEN LIMIT LED will blink.
PROGRAM OPEN
3
Press and hold the GATE 1 left button to move the gate to the desired OPEN position. When the gate is in the desired position, release the button. NOTE: The Gate 1 right and left buttons can be used to jog the gate back and forth as needed.
ey t id r s e In op r
6
SET CLOSE LIMIT
LEARN LIMITS
GATE 2 G
When the gate is in the desired OPEN position, press and release and release the LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS LED will blink.
3
PROGRAM CLOSE
5
SET N OPEN LIMIT
P
4
GATE A 1
PrOut op sid er e ty
2 4
GATE 1 Left Button
LEARN LIMITS Button
LEARN LIMITS Button
DIAGNOSTIC
Press and hold the GATE 1 right button to move the gate to the desired CLOSED position. When the gate is in the desired position, release the button. NOTE: The Gate 1 right and left buttons can be used to jog the gate back and forth as needed. When the gate is in the desired CLOSED position, press and release the LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS LED will stop blinking.
GATE A 1
GATE 1
SET CLOSE LIMIT
"
EEP
SET CLOSE
5
SET OPEN LIMIT
"B
LEARN LIMITS
GATE 2 G
6 LEARN LIMITS Button
GATE 1 Right Button DIAGNOSTIC
GATE A 1
GATE 1
Programming is now complete. (If the SET OPEN LIMIT LED continues to blink, repeat programming or refer to the following page.) Test the limits by pressing the SINGLE BUTTON to open and close the gate.
SET OPEN LIMIT
SET CLOSE
SET CLOSE LIMIT
DUAL GATES Refer to the installation manual for dual gate programming. 2
"
EEP
"B
LEARN LIMITS
GATE 2 G
IF THE LIMITS WILL NOT PROGRAM
Learn Limit Nut
3
1 2 Manually close the gate. 3 Remove the learn limit cover and move the learn limit nut to the center position. 4 Press the reset switch to NORMAL OPERATION. Disconnect the operator by pressing the reset switch to RESET/DISCONNECT.
Learn Limit Switch
1 RESET/ DISCONNECT
Program the limits again.
NORMAL OPERATION
4
FORCE ADJUSTMENT
The operator is equipped with an obstruction sensing feature. If the gate encounters an obstruction the operator will automatically reverse direction for a short time and stop. Based on the length and weight of the gate it may be necessary to make force adjustments. The force adjustment should be high enough that small objects such as branches or wind will not cause nuisance interruptions but low enough to prevent serious injury to a person or a vehicle.
1 2
SINGLE BUTTON
1
Use the SINGLE BUTTON to open and close the gate.
FORCE
If the gate stops or reverses before reaching the fully open or closed position increase the force by turning the force control clockwise.
2
3 If the gate hits a rigid object and does not stop or reverse, decrease the force by turning the
OFF
MAX
force control counterclockwise.
4 Run operator through a complete cycle and verify proper operation. NOTE: Weather conditions can affect the gate movement, so seasonal adjustment may be required. The force control is factory set to the mid-position.
TEST After any adjustments are made, test the operator:
1 Use the SINGLE BUTTON to open and close the gate.
SINGLE BUTTON
1
2 Test the limits by making sure the gate is stopping at the OPEN and CLOSE limits. the force by making sure the gate will stop and reverse direction for a short time on 3 Test contact with an obstruction.
PrOut op sid er e ty
2 ey t id r s e In op r
P
3
PrOut op sid er e ty
ey t id r s e In op r P
3
PROGRAMMING A combined total of 50 remote controls and keyless entry PINs can be programmed to the operator. TO ADD OR REPROGRAM A REMOTE CONTROL (NOT PROVIDED)
1 2
1
Press and release the LEARN XMITTER button (LED will light).
LEARN XMITTER
Press the remote control button. The LED will flash and the alarm output will activate twice.
To program additional remote controls, repeat the steps until all the remote controls are programmed.
TO ADD, REPROGRAM OR CHANGE A WIRELESS KEYLESS ENTRY PIN (NOT PROVIDED)
1 2
2
1
LEARN XMITTER
Press and release the LEARN XMITTER button (LED will light). Enter a 4-digit personal identification number (PIN) of your choice on the keypad.
2
the ENTER button on the keypad. The LED will flash and the alarm output will 3 Press activate twice.
ERASE ALL CODES Press and hold the LEARN XMITTER button on the control board until the learn indicator light goes out (approximately 6 seconds). All previous codes are now erased. NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
01-35675
© 2009, The Chamberlain Group, Inc. All Rights Reserved
1
PIN Number
? ? ? ?
LEARN XMITTER