Preview only show first 10 pages with watermark. For full document please download

Linea Clima General Catalogue 2012

   EMBED


Share

Transcript

True life inside LINEA CLIMA GENERAL CATALOGUE 2012 For more than 30 years carefully treating air and water to guarantee a more comfortable life. Everyday . By contacting Gruppo Ferraro means you can count on a single important reference point. A reliable supplier, moreover an experienced, qualified and proactive partner. The three companies making the Gruppo Ferraro areIndustrie Ferraro, LMF Clima and Rame Cz work in perfect synergy and for more than thirty years have worked in the fields of liquid and gas coduction, manufacturing components for their use in numerous fields such as heating, air conditioning, refrigeration and automation. Through constant investment in machinery, equipment and technology applied to the treatment of air and the recovery of clean energy, has allowed Gruppo Ferraroto consolidate its leading role in this field. Ferraro Group. Three companies, one trustworthy partner. This natural and spontaneous tendency to continuously evolve in infrastructures and production processes has been the key to success which started at the Group’s birth, keeps evolving in the present and is the starting point for the its’ future. Quality. Our value since 1980. The company LMF Clima of the Ferraro Group,designs and manufactures equipment and units for air-conditioning, heating and air-treatment systems. Founded in 1980, LMF Clima distinguishes itself for its ability to develop skills and processes, with the aim of ensuring the highest quality of its products. In 1996 LMF designed its first complete line of air treatment, thereby becoming an essential reference point to those in the sector. After 30 years of experience, LMF carries out its designs on a surface of 10.000MQ with state of the art machinery and equipment and offers solutions which meet the needs of an extremely demanding market, where the ratio of Quality/price is the discriminating factor. The will to introduce itself as a valued and proactive partner, one willing to attentively evaluate various new solutions that technology has to offer is LMF’s main aim. INDEX Heat recovery unit 8 RKE Heat recovery unit Pag. 14 RKE BP Heat recovery unit with free cooling Pag. 24 RKE FO Heat recovery unit with high ef ciency lters, plug and play Pag. 30 RKE BF Heat recovery unit with free cooling, high ef ciency lters, plug and play Pag. 36 UTW-REC High air ow heat recovery unit Pag. 42 RKH High ef ciency heat recovery unit Pag. 48 RKS 90% heat recovery unit plug and play Pag. 54 RKS 3V 90% heat recovery unit Pag. 60 SRS 90% ef ciency heat recovery unit Pag. 66 SRS BF 90% ef ciency heat recovery unit with free cooling, plug and play Pag. 72 TWR Rotary high ef ciency heat recovery unit Pag. 76 RFM Heat recovery unit with built-in heat pump system Pag. 82 HPX Heat recovery unit with built-in heat pump system Pag. 88 Index www.lmf.it Air handling unit BAW Ductable terminal unit Pag. 94 FSM Compact air conditioning unit Pag. 100 FSM T High pressure compact air conditioning unit Pag. 108 UTW Air conditioning unit Pag. 116 FLEX Air handling unit Pag. 124 CTE Direct driven fan box Pag. 134 CTT Belt driven fan box Pag. 138 SIL Low noise fan unit Pag. 140 EKA Low body fan box Pag. 144 Fan Unit Index www.lmf.it 9 Recovery efficiency (%) Q Range overview Airflow (m³/h) 10 Index www.lmf.it External Static Pressure (Log Pa) Airflow (Log m³/h) Index www.lmf.it 11 Q Main feautures Model Efficiency Efficiency Efficiency Efficiency >50% >70% >80% >90% Plug&Play H V EC FANS INSIDE PARTIAL OUTSIDE RKE √ √ √ √ √ RKE BP √ √ √ √ √ RKE FO √ √ √ √ √ √ √ RKE BF √ √ √ √ √ √ √ UTW-REC √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ RKH RKS √ RKS 3V √ SRS √ SRS BF √ √ √ √ √ √ √ √ √ √ √ TWR BAW √ FSM √ √ FSM T √ √ UTW √ √ √ √ √ √ √ √ CTE √ √ CTT √ √ SIL √ EKA √ FLEX Model RFM √ R410A R407C √ √ HPX 12 √ √ Scroll Plug&Play √ √ √ √ Rotary √ √ HP FULL OUTSIDE √ √ Efficiency >50% INSIDE PARTIAL OUTSIDE √ √ √ √ √ √ √ √ FULL OUTSIDE √ Index www.lmf.it Q Legenda Efficiency >50% Efficiency >70% Efficiency >80% Efficiency >90% Plug&Play Heat recovery ef ciency more than 50% R410A Refrigerant gas R410A Heat recovery ef ciency more than 70% R407C Refrigerant gas R407C Heat recovery ef ciency more than 80% HP Heat recovery ef ciency more than 90% Rotary Hermetic rotary compressors Scroll Hermetic scroll compressors Multifunction electronic control built-in H Horizontal unit for false ceiling or oor installation (support legs not included) V Vertical unit for oor installation (support legs included) EC FANS Reversible heat pump refrigerant circuit Inverter controlled direct driven centrifugal fans For indoor installation only INSIDE PARTIAL OUTSIDE For indoor and outdoor installation in a protected position, roof cover and support legs are suggested For indoor and outdoor installation FULL OUTSIDE Index www.lmf.it 13 RKE Efficiency >50% H V INSIDE PARTIAL OUTSIDE RKE Heat recovery unit from 200 to 6.800 m³/h Q General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants, by using an aluminum plated cross ow heat exchanger, able to transfer more than 50% of heat which otherwise would be lost with air exhaust. These units may be integrated with traditional heating and cooling systems (such as fan-coils, water heaters, etc.) and can operate both in summer and winter seasons. RKE series consists of 10 models, with air ow rate from 200 m³/h to 6800 m³/h; all the units are particularly suitable for false ceiling installation and may be appropriately ducted allowing air supply and air suction directly in the room. RKE units are available in the following base versions: RKE horizontal unit RKE/V vertical unit. Q Mechanical features Fully removable panels (sandwich type). Acoustic and thermal panel insulation (thickness 10 mm for RKE 03-06-10 models and 20 mm for bigger models). High ef ciency aluminum plated heat recovery - EUROVENT certi ed - with air ows separated by special seals. G4 ef ciency class air lters, easily removable everywhere (bottom, side, top) allowing their periodic cleaning; as an option, F6-F7-F8 ef ciency class soft bag lters. Fans mounted on a easy removable support. Double inlet centrifugal fans, with multi-speed direct driven motor. The unit is complete of electrical terminal box tted with relay board, to aid the electrical connections and fan control. Galvanized steel condensate drain tray, with discharge from the bottom side. 14 Heat recovery unit www.lmf.it Q Accessories SKW SKE SAF V33 CDM SED MS3 LCS SKR SSE FC6 FT6 FT7 FT8 HCP VSA BCC GAT STEEL Roof cover TPR External hood CFA Supports H=180 mm PD2 Inverter driven fan motors DDE Fan speed control for DDE RDE Air lter pressure switch PSTD Room hygrostat HAS Ductable hygrostat HCS 3 step fan speed control CVU Control panel PCR Remotable temperature sensor for PCR NTC Antifreeze thermostat TEG Electronic control LCE Multifunction electronic control RQU Differential pressure transducer DPS Ductable CO2 transducer AQS Air quality control system KAQ RKE Internal water heating coil Pre or post electric heater External water cooling coil section 3 way valve with actuator External by-pass for free-cooling External direct expansion coil section 3 damper mixing box section Damper connection lever Adjusting damper on/off damper actuator F6 class compact lter F6 class soft bag lter F7 class soft bag lter F8 class soft bag lter External umidi cation/adiabatic cooling section Solenoid valve Round adapter for circular duct Flexible joint FRAME AND INSULATED SANDWICH PANEL CEILING FIXING SYSTEM OF THE UNIT ELECTRIC BOARD WITH RELAYS THE BEST POSSIBILITY OF INSPECTION, MAINTENANCE AND REPLACEMENT OF ALL THE INTERNAL COMPONENTS, ALSO CONDENSATE DRAIN TRAY MOVABLE FOR CLEANING AND MAINTENANCE IF THE UNIT IS ALREADY INSTALLED THE ELECTRIC CONNECTION BOX WITH RELAYS BOARD FOR LOAD POWER MANAGING ROUND ADAPTER FOR CIRCULAR DUCT Heat recovery unit www.lmf.it 15 Q Model RKE Max Air ow Med m³/h Min RKE Max External Static Pressure Med Pa Min Max Sound pressure level at 1 m Med dB(A) Min Full load total current 03 06 10 14 19 25 30 40 50 60 300 500 930 1400 1900 2500 3200 4000 5000 6000 200 300 750 1200 1400 1700 2500 - - - 100 150 600 850 1000 1100 1800 3000 4000 5000 163 121 100 129 125 120 114 120 99 188 184 136 115 100 97 56 164 - - - 167 144 90 91 82 68 142 105 139 208 51,1 51,1 52,2 62,3 58,4 56,0 58,8 62,1 63,7 64,5 49,7 47,4 48,8 56,9 53,7 51,0 53,5 - - - 44,3 41,0 45,3 45,6 42,1 44,6 51,1 54,9 59,1 62,0 A 1,40 1,40 4,00 6,00 7,80 7,60 12,6 6,20 11,2 10,8 W/(m3/s) 1376 1019 1003 1418 1172 1019 1301 1183 1428 1594 Fan speeds n° 3 3 3 3 3 3 3 2 2 2 Poles n° 2 2 4 4 4 4 4 4 4 4 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 B B B B B B B B B B Speci c fan power Motor protection rating Motor insulation class Electrical power supply V-Ph-Hz Max Ef ciency (1) Med % Min Max Recovered heating capacity (1) Med kW Min Max Supply temperature (1) Med °C Min 230-1-50 400-3+N-50 53,3 58,7 57,0 51,2 50,3 55,5 53,9 54,9 53,8 55,7 62,2 58,5 52,1 52,1 57,9 55,5 - - 53,1 - 59,6 66,8 60,0 54,1 54,0 60,6 57,5 56,7 55,3 54,3 1,30 2,40 4,40 6,00 7,90 11,5 14,3 18,2 22,4 26,5 0,90 1,60 3,60 5,20 6,10 8,20 11,5 - - - 0,50 0,80 3,00 3,80 4,50 5,50 8,60 14,1 18,4 22,6 7,1 8,3 7,9 6,6 6,4 7,6 7,2 7,4 7,2 7,1 7,6 9,1 8,3 6,8 6,8 8,1 7,6 - - - 8,5 10,1 8,6 7,3 7,3 8,7 8,0 7,9 7,5 7,3 Water cooling accessory SAF Rows 3 3 3 3 3 3 3 3 3 3 Air pressure drop Max Pa 43 59 63 81 83 64 84 84 66 69 Total cooling capacity (2) Max kW 2,30 3,10 5,70 8,20 10,8 16,5 19,2 24,0 27,9 28,2 Sensible cooling capacity (2) Max kW 1,38 1,86 3,42 4,92 6,48 9,90 11,5 14,4 16,7 16,9 Supply temperature (2) Max °C 19,5 20,9 20,9 21,7 21,9 20,6 21,5 21,3 21,3 21,3 Water ow rate (2) Max m³/h 0,40 0,53 0,98 1,41 1,86 2,84 3,30 4,13 4,80 4,85 Water pressure drop (2) Max kPa 6 11 15 9 10 22 29 30 27 24 - - 3 3 3 3 3 3 3 3 Air pressure drop Max Pa - - 58 63 85 62 85 90 94 111 Heating capacity (3) Max kW - - 9,60 14,9 18,6 26,9 31,5 39,5 46,7 53,8 Supply temperature (3) Max °C - - 35,1 34,3 32,0 35,6 33,0 33,2 28,8 27,9 Water ow rate (3) Max m³/h - - 0,83 1,28 1,60 2,31 2,71 3,40 4,02 4,63 Water pressure drop (3) Max kPa - - 15 41 28 21 29 53 23 26 1 1 1 1 1 1 1 1 1 1 kW 2,00 4,00 4,50 6,00 9,00 12,0 12,0 12,0 18,0 24,0 Max °C 19,6 23,5 14,2 12,6 13,9 14,1 11,0 8,8 10,6 11,8 Max Pa 5 5 8 8 11 7 10 11 13 15 Water post-heating accessory SKW Rows Electric pre or post-heating accessory SKE Stages Heating capacity T air side Pressure drop Electrical power supply V-Ph-Hz 230-1-50 400-3+N-50 High ef ciency lters FC6 Pressure drop Max Pa - - 26 45 51 43 50 47 38 34 FT6 Pressure drop Max Pa - - - 145 170 162 172 189 175 179 FT7 Pressure drop Max Pa - - - 171 199 191 197 229 205 185 FT8 Pressure drop Max Pa - - - 214 239 230 238 260 248 225 mm 200 200 315 315 315 355 400 450 600 600 Circular duct supply connector BCC Diameter (1) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C outlet 12°C (3) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH, water inlet 70°C outlet 60°C 16 Heat recovery unit www.lmf.it Q Max fan speed air performances 600 30 50 40 25 60 400 06 19 14 52,0 10 03 300 60,5 65,5 56,0 57,3 200 RKE External Static Pressure (Pa) 500 61,4 55,8 64,5 51,1 62,3 100 58,8 56,0 58,4 52,2 51,1 62,1 63,7 64,9 59,0 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Air ow (m³/h) Q Medium fan speed air performances 500 30 450 External Static Pressure (Pa) 400 56,5 25 350 14 06 300 49,7 03 56,1 10 250 19 55,0 55,4 50,3 47,4 200 150 51,3 56,9 48,8 49,7 53,5 53,7 100 51,0 48,6 50 49,1 51,9 56,7 0 0 500 1000 1500 2000 2500 3000 Air ow (m³/h) Q Minimum fan speed air performances 350 60 30 50 External Static Pressure (Pa) 300 40 61,9 54,7 250 03 200 06 55,1 25 14 62,0 19 45,5 10 41,0 150 100 59,1 51,1 45,6 45,3 42,1 44,6 54,9 44,3 38,2 50 62,4 62,4 55,7 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Air ow (m³/h) Heat recovery unit www.lmf.it 17 Q Dimensions and weight RxT O RxT RxT RKE SKR Q P d SAF-SED MS3 RKE Q Dimensions and weight RKE 03 06 10 14 19 25 30 40 50 60 A B C D Ø E F G H H1 L L1 M Weight mm mm mm mm () mm mm mm mm mm mm mm mm kg 990 750 270 195 170 197 100 153 162 275 -- (119) 39 990 750 270 195 170 197 100 153 162 275 -- (119) 41 1150 860 385 230 ¾” 245 238 225 218 267 240 330 -- (81) 68 1350 900 410 230 ¾” 241 224 241 270 267 240 337 -- (81) 91 1450 900 470 280 ¾” 241 284 241 270 327 240 337 -- (81) 99 1700 1230 490 305 ¾” 323 290 323 270 347 306 502 -- (131) 140 1700 1230 530 305 ¾” 308 331 323 297 387 339 502 -- (101) 155 1700 1230 630 405 ¾” 308 377 323 297 487 339 502 -- (101) 179 1700 1350 705 480 1” 353 (278) 427 (353) 353 297 (339) 555 339 (297) 555 -- (101) 235 1900 1450 755 530 1” 379 (334) 419 (379) 379 350 (403) 615 403 (350) 615 -- (101) 273 O P Q R S T d mm mm mm mm mm mm ('') 375 400 210 75 280 ¾” 375 400 210 75 280 ¾” 430 400 450 310 75 330 ¾” 450 700 480 310 75 330 ¾” 450 700 480 410 100 330 ¾” 615 700 650 410 150 500 1” 615 700 650 410 150 500 1” 615 800 650 510 150 500 1” 675 850 707 610 175 600 1 ½” 725 900 757 610 200 600 1 ½” Where different, within brackets, dimensions and weight of vertical version. 18 Heat recovery unit www.lmf.it CDM RKE Filter HORIZONTAL UNIT Possible post-heating CDM VERTICAL UNIT Heat recovery unit www.lmf.it 19 Q RKE possible installations (Horizontal version) TYPE A TYPE B INSIDE OUTSIDE RKE INSIDE R90 A90 Fresh air E90 Exhaust air OUTSIDE M90 E90 Return air Exhaust air Supply air Fresh air M90 Supply air A90 TYPE C R90 Return air TYPE D INSIDE Supply air Fresh air Exhaust air Return air M90 R90 E90 A90 E90 A90 M90 R90 Fresh air Exhaust air OUTSIDE Return air Supply air OUTSIDE INSIDE Q RKE/V possible installations (Vertical Version) Vertical con guration (with re-heating system - only type B or C) TYPE B TYPE A A90 R90 E90 Fresh air Return air Exhaust air Supply air Exhaust air Supply air Fresh air Return air E90 A90 M90 TYPE C M90 R90 TYPE D R90 E90 A90 Supply air Return air Exhaust air Fresh air Exhaust air Fresh air Supply air Return air E90 20 M90 A90 M90 R90 Heat recovery unit www.lmf.it Q Controls Speed control CVU RKE It is composed of a 2/3 step fan speed control (min/med/max air speed) and a manual off/ cooling/heating switch, capable of connecting an antifreeze thermostat (accessory TEG) that can stop the unit in heating mode. Accessories TEG Antifreeze thermostat Control Panel PCR This digital controller is intended for temperature regulation in environments equipped with heat recovery unit or air conditioning unit. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the control panel internal sensor or with an external one (accessory NTC). The control panel is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) and/or electric heater; moreover it includes a manual or automatic heating/cooling changeover, an economy function to reduce power consumption (it allows to temporary set an energy saving mode through a reduction of the actual set point temperature by a step when in heating mode, or increasing it by the same step when in cooling mode), and clogged lter alarm by setting the time-to-maintenance. This device can drive in a proportional way both valves and fan in order to control room temperature with the highest comfort and energy saving, following a proportional band for fan and proportional and integral for valves: the regulator will drive this valve through power pulses with one second resolution in a way that its stem will reach the position needed for the regulation, thus performing a modulation. The regulator, as soon as power is rst applied, and before it starts the actual regulation, will perform a stem position re-synchronization cycle, which is obtained by closing the valve for a time which is 150% of the value stored as nominal opening time. This cycle will be periodically repeated in order to recover possible positioning errors which might be accumulated during time. Accessories SKW internal water heating coil SKE post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V NTC remotable temperature sensor for PCR TEG antifreeze thermostat (it can be connected by an electro mechanic wiring thus no alarm is displayed on control panel) SSE on/off damper spring actuator (only in combination with TEG accessory, by an electro mechanic wiring) Heat recovery unit www.lmf.it 21 RKE Electronic control LCE It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with a supply air sensor or with the remote control panel internal sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric heater and free-cooling/freeheating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF, sensors diagnostic and integrated scheduling clock with four programs for each day of the week. Accessories SKW internal water heating coil SKE post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V CDM external by-pass section for free-cooling PSTD air lter pressure switch Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control or continuous control with DDE-DDB, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater and mixing box), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. 22 Heat recovery unit www.lmf.it RKE Accessories SKW internal water heating coil SKE pre or post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V CDM external by-pass section for free-cooling MS3 3 damper mixing box SSE on/off spring actuator for damper PSTD air lter pressure switch DDE inverter driven fan motors AQS ductable CO2 transducer (only with DDE) DPS ductable differential pressure transducer (only with DDE) enables constant pressure ow VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat SS P P SS SS TR TM SS SV SV Air ow control KAQ It is composed of a complete air quality control system, non related to the main control chosen, but has to be installed to accessory DDE: it includes a ductable CO2 transducer, an electronic control with analog output and a 24V transformer, all fully wired in an electrical panel onboard. KAQ Heat recovery unit www.lmf.it 23 RKE BP RKE BP Efficiency H >50% V INSIDE PARTIAL OUTSIDE Heat recovery unit with free cooling from 400 to 6.200 m³/h Q General features The RKE BP unit has the same characteristics as the RKE unit, but with one difference only: the system able to exclude the recovery exchanger; this working function is called free-cooling , it uses the fresh air at the temperature to get easy the room cooling. RKE BP series consist in 6 models with air ow range from 400 m³/h to 6200 m³/h. RKEBP units are available in the following base versions: RKE BP horizontal unit with by-pass RKE BP/V vertical unit with by-pass Q Mechanical features Fully removable panels (sandwich type). Acoustic and thermal panel insulation. High ef ciency aluminum plated heat recovery - EUROVENT certi ed The by-pass was made by a special motorised system that it keep the same air ow when the unit is working in the standard way or in free-cooling. G4 ef ciency class air lters; as an option, F6-F7-F8 ef ciency class soft bag lters. Double inlet centrifugal fans with multi-speed direct driven motor. The unit is complete of electrical terminal box tted with relay board, to aid the electrical connections and fan control. Galvanized steel condensate drain tray, with discharge from the bottom side. 24 Heat recovery unit www.lmf.it Q Accessories SKW SKE SAF V33 SED MS3 LCS SKR SSE FC6 FT6 FT7 FT8 HCP VSA INTERNAL BY-PASS Round adapter for circular duct Flexible joint Roof cover External hood Supports H=180 mm Inverter driven fan motors Fan speed control for DDE Air lter pressure switch Room hygrostat Ductable hygrostat Electronic control Multifunction electronic control Differential pressure transducer Ductable CO2 transducer Air quality control system BCC GAT TPR CFA PD2 DDE RDE PSTD HAS HCS LCE RQU DPS AQS KAQ FOR FREE-COOLING Heat recovery unit www.lmf.it RKE BP Internal water heating coil Pre or post electric heater External water cooling coil section 3 way valve with actuator External direct expansion coil section 3 damper mixing box section Damper connection lever Adjusting damper On/off damper actuator F6 class compact lter F6 class soft bag lter F7 class soft bag lter F8 class soft bag lter External umidi cation/adiabatic cooling section Solenoid valve 25 Q Model RKE BP Max RKE BP Air ow Med m³/h Min Max External Static Pressure Med Pa Min Max Sound pressure level at 1 m Med 10 14 19 30 40 60 750 1100 1600 2600 3400 5500 600 1000 1400 2250 - - 500 800 1000 1500 2500 4000 160 119 115 145 144 156 115 108 38 141 - - 90 63 48 176 155 269 52 59 58 58 61 64 - - dB(A) Min Full load total current A 4,00 6,00 7,80 12,6 6,20 10,8 W/(m3/s) 1106 1418 1219 1340 1152 1567 Fan speeds n° 3 3 3 3 2 2 Poles n° 4 4 4 4 4 4 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 B B B B B B Speci c fan power Motor protection rating Motor insulation class Electrical power supply V-Ph-Hz Max Ef ciency (1) Med % Min Max Recovered heating capacity (1) Med kW Min Max Supply temperature (1) Med °C Min 230-1-50 400-3+N-50 55,9 50,7 50,1 53,5 53,5 57,4 51,2 50,8 54,4 - 52,8 - 58,7 52,5 52,8 57,0 55,5 54,9 24,1 3,50 4,60 6,70 11,6 15,1 2,90 4,30 5,90 10,2 - - 2,40 3,50 4,40 7,10 11,5 18,2 7,0 7,7 6,5 6,4 7,1 7,1 8,0 6,6 6,5 7,3 - - 8,3 6,9 7,0 7,9 7,6 7,4 Water cooling accessory SAF 3 3 3 3 3 3 Air pressure drop Rows Max Pa 45 56 64 61 64 60 Total cooling capacity (2) Max kW 5,20 7,20 9,90 17,0 22,2 27,3 Sensible cooling capacity (2) Max kW 3,12 4,32 5,94 10,2 13,3 16,4 Supply temperature (2) Max °C 20,3 21,1 21,4 20,8 20,9 21,0 Water ow rate (2) Max m³/h 0,89 1,24 1,70 2,92 3,82 4,70 Water pressure drop (2) Max kPa 13 7 9 23 26 23 3 3 3 3 3 3 Max Pa 42 43 65 61 69 97 Water post-heating accessory SKW Rows Air pressure drop Heating capacity (3) Max kW 8,40 12,8 16,8 27,8 36,0 51,3 Supply temperature (3) Max °C 37,4 36,8 33,7 35,0 34,7 28,5 Water ow rate (3) Max m³/h 0,72 1,10 1,44 2,39 3,10 4,41 Water pressure drop (3) Max kPa 12 31 23 22 44 24 1 1 1 1 1 1 kW 4,50 6,00 9,00 12,0 12,0 24,0 Max °C 17,6 16,0 16,5 13,6 10,4 12,8 Max Pa 6 6 8 8 8 13 Electric pre or post-heating accessory SKE Stages Heating capacity T air side Pressure drop Electrical power supply V-Ph-Hz 400-3+N-50 High ef ciency lters FC6 Pressure drop Max Pa - 32 41 37 39 31 FT6 Pressure drop Max Pa - 112 141 137 157 163 FT7 Pressure drop Max Pa - 132 165 156 191 184 FT8 Pressure drop Max Pa - 164 197 189 229 230 mm 315 315 315 400 450 600 Round adapter for circular duct BCC Diameter (1) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C outlet 12°C (3) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH, water inlet 70°C outlet 60°C 26 Heat recovery unit www.lmf.it Q Max fan speed air performances 600 30 400 RKE BP External Static Pressure (Pa) 500 58,5 40 300 60 61,0 19 10 63,3 56,6 14 57,9 52,0 200 58,8 59,1 100 64,0 61,4 58,0 52,0 59,4 60,1 59,2 64,5 62,2 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 Air ow (m³/h) Q Medium fan speed air performances 500 30 450 External Static Pressure (Pa) 400 56,5 350 300 19 14 250 55,0 10 200 150 55,4 50,3 56,1 54,5 100 50 57,0 53,0 48,3 51,9 0 0 500 1000 1500 2000 2500 3000 Air ow (m³/h) Q Minimum fan speed air performances 350 30 External Static Pressure (Pa) 300 60 250 61,9 40 200 19 14 10 48,8 150 55,1 54,7 51,5 62,1 100 52,9 47,9 45,5 45,8 50 44,5 54,9 45,9 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 Air ow (m³/h) Heat recovery unit www.lmf.it 27 Q Controls RKE BP Electronic control LCE It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with a supply air sensor or with the remote control panel internal sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric heater and free-cooling/ free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF, sensors diagnostic and integrated scheduling clock with four programs for each day of the week. Accessories SKW SKE SAF V33 PSTD internal water heating coil post heating electric heater external water cooling/heating coil 3 way valve with 3 points actuator 230V air lter pressure switch Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control or continuous control with DDE-DDB, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater and mixing box), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. 28 Heat recovery unit www.lmf.it RKE BP Accessories SKW internal water heating coil SKE pre or post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V MS3 3 damper mixing box SSE on/off spring actuator for damper PSTD air lter pressure switch DDE inverter driven fan motors AQS ductable CO2 transducer (only with DDE) DPS ductable differential pressure transducer (only with DDE) enables constant pressure ow VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat SS P P SS SS TR TM SS SV SV Air ow control KAQ It is composed of a complete air quality control system, non related to the main control chosen, but has to be installed to accessory DDE: it includes a ductable CO2 transducer, an electronic control with analog output and a 24V transformer, all fully wired in an electrical panel onboard. KAQ Heat recovery unit www.lmf.it 29 RKE FO RKE FO Efficiency Plug&Play >50% H V EC FANS INSIDE PARTIAL OUTSIDE Heat recovery unit with high ef ciency lters, plug and play from 400 to 6.800 m³/h Q General features The RKE FO unit has the same characteristics as the RKE unit, but the RKE FO versions included: 1. motor with frequency converter (DDE as standard) 2. high ef ciency lters, class F6-F7-F8 3. air lter pressure switches (PSTD as standard) 4. electronic built-in control (RQU as standard) for: Heating/cooling/free-cooling automatic mode (2/4 pipe plant) antifreeze electric heater on/off mode winter heating speed-up heat recovery defrost manual or automatic fan speed selection dirty lter alarm timer RKE FO units are available in the following base versions: RKE FO horizontal unit RKE FO/V vertical unit Version Version Version Version Version Version 30 FO2 FO3 FO4 FO5 FO6 FO7 with with with with with with G4 G4 G4 F6 F6 F6 lter on return and G4+F6 on supply side lter on return and G4+F7 on supply side lter on return and G4+F8 on supply side lter on return and F6 on supply side lter on return and F6+F7 on supply side lter on return and F6+F8 on supply side Heat recovery unit www.lmf.it Q Accessories Internal water heating coil Pre or post electric heater External water cooling coil section 3 way valve with actuator External by-pass for free-cooling External direct expansion coil section 3 damper mixing box section Damper connection lever Adjusting damper On/off damper actuator External umidi cation/adiabatic cooling section Solenoid valve Round adapter for circular duct Flexible joint Roof cover External hood Supports H=180 mm Room hygrostat Ductable hygrostat Differential pressure transducer Ductable CO2 transducer EFFICIENCY FILTER WITH DIFFERENTIAL RKE FO HIGH SKW SKE SAF V33 CDM SED MS3 LCS SKR SSE HCP VSA BCC GAT TPR CFA PD2 HAS HCS DPS AQS ON-BOARD ELECTRONIC PANEL CONTROL PRESSURE SWITCH STEEL FRAME AND INSULATED SANDWICH PANEL ROUND ADAPTER FOR CIRCULAR DUCT Heat recovery unit www.lmf.it 31 Q Model RKE FO Nom m³/h Max Min Nom Sound pressure level at 1 m dB(A) Max Min Full load total current A Speci c fan power W/(m³/s) Motor protection rating Motor insulation class Electrical power supply 14 19 25 30 40 50 60 1400 1900 2500 3200 4000 5000 6000 1400 1850 2200 3000 4000 4500 5200 6600 400 600 700 1200 1300 2000 3000 4000 52,0 60,0 62,0 64,0 63,0 65,0 63,0 64,0 53,0 61,0 63,0 62,0 62,0 64,0 64,0 65,0 51,0 59,0 61,0 66,0 64,0 68,0 60,0 63,0 12,0 12,6 15,6 15,6 16,0 16,4 33,2 33,2 1829 1668 1575 1967 1613 1326 1402 1595 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 20 IP 20 F F F F F F F F V-Ph-Hz Nom Ef ciency (1) % Max Recovered heating capacity (1) 56,9 51,2 50,3 55,5 53,9 54,9 53,8 53,1 54,0 49,5 49,4 54,3 53,1 54,1 53,6 52,5 Min 62,7 56,1 56,1 60,0 59,6 59,2 57,1 55,7 4,40 6,00 7,90 11,5 14,3 18,2 22,4 26,5 Max kW Nom Supply temperature (1) 230-1-50 Nom Min Max °C Min 6,30 7,60 9,00 13,5 15,9 20,2 23,2 28,8 2,10 2,80 3,30 6,00 6,40 9,80 14,2 18,5 7,9 6,6 6,4 7,6 7,2 7,4 7,2 7,1 7,3 6,2 6,2 7,3 7,1 7,3 7,2 6,9 9,2 7,7 7,7 8,6 8,5 8,4 7,9 7,6 High ef ciency lters FC6 Pressure drop Max Pa 26 45 51 43 50 47 38 34 FT6 Pressure drop Max Pa - 145 170 162 172 189 175 179 FT7 Pressure drop Max Pa - 171 199 191 197 229 205 185 FT8 Pressure drop Max Pa - 214 239 230 238 260 248 225 (1) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH Q Max fan speed air performances RKE FO 10 600 G4 FC6 500 External Static Pressure (Pa) RKE FO Air ow 10 930 51,0 400 52,0 300 53,0 200 100 0 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Air ow (m³/h) 32 Heat recovery unit www.lmf.it RKE FO 14 600 G4 500 FC6+FT7 RKE FO External Static Pressure (Pa) 59,0 FC6 FC6+FT8 400 60,0 300 200 61,0 100 0 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 Air ow (m³/h) RKE FO 19 G4 600 61,0 FC6 FC6+FT7 FC6+FT8 External Static Pressure (Pa) 500 400 62,0 300 63,0 200 100 0 600 800 1000 1200 1400 1600 1800 2000 2200 Air ow (m³/h) RKE FO 25 900 G4 External Static Pressure (Pa) 800 700 66,0 FC6 FC6+FT7 FC6+FT8 600 500 64,0 400 300 62,0 200 100 0 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900 3100 Air ow (m³/h) Heat recovery unit www.lmf.it 33 RKE FO 30 700 G4 FC6 64,0 FC6+FT7 600 External Static Pressure (Pa) 500 400 300 63,0 200 100 62,0 0 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 Air ow (m³/h) RKE FO 40 800 G4 FC6 700 68,0 External Static Pressure (Pa) FC6+FT7 FC6+FT8 600 500 67,0 400 300 200 65,0 100 0 1900 2100 2300 2500 2700 2900 3100 3300 3500 3700 3900 4100 4300 4500 4700 Air ow (m³/h) RKE FO 50 500 G4 FC6 60,0 400 External Static Pressure (Pa) RKE FO FC6+FT8 FC6+FT7 300 FC6+FT8 62,0 200 100 64,0 0 2900 3100 3300 3500 3700 3900 4100 4300 4500 4700 4900 5100 5300 Air ow (m³/h) 34 Heat recovery unit www.lmf.it RKE FO 60 500 G4 63,0 FC6 RKE FO External Static Pressure (Pa) 400 64,0 300 FC6+FT7 FC6+FT8 200 100 65,0 0 3900 4100 4300 4500 4700 4900 5100 5300 5500 5700 5900 6100 6300 6500 6700 6900 Air ow (m³/h) Q Controls Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control or continuous control, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater and mixing box), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories SKW internal water heating coil SKE pre or post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V CDM external by-pass section for free-cooling MS3 3 damper mixing box SSE on/off spring actuator for damper AQS ductable CO2 transducer DPS ductable differential pressure transducer, enables constant pressure ow VSA solenoid valve for adiabatic humidi cation/ cooling HAS room hygrostat HCS ductable hygrostat SS P P SS SS TR TM SS SV SV Heat recovery unit www.lmf.it 35 RKE BF RKE BF Efficiency Plug&Play H >50% V EC FANS INSIDE PARTIAL OUTSIDE Heat recovery unit with free cooling, high ef ciency lters, plug and play from 400 to 6.200 m³/h Q General features The RKE BF unit has the same characteristics as the RKE unit, but the RKE BF versions included: 1. motorized integrated by-pass 2. motor with frequency converter (DDE as standard) 3. high ef ciency lters, class F6-F7-F8 4. air lter pressure switches (PSTD as standard) 5. electronic built-in control (RQU as standard) for: Heating/cooling/free-cooling automatic mode (2/4 pipe plant) antifreeze electric heater on/off mode winter heating speed-up heat recovery defrost manual or automatic fan speed selection dirty lter alarm timer RKE BF units are available in the following base versions: RKE BF horizontal unit; RKE BF/V vertical unit; Version Version Version Version Version Version Version 36 BF1 BF2 BF3 BF4 BF5 BF6 BF7 with with with with with with with G4 G4 G4 G4 F6 F6 F6 lter on return and F6 on supply side lter on return and G4+F6 on supply side lter on return and G4+F7 on supply side lter on return and G4+F8 on supply side lter on return and F6 on supply side lter on return and F6+F7 on supply side lter on return and F6+F8 on supply side Heat recovery unit www.lmf.it Q Accessories Internal water heating coil Pre or post electric heater External water cooling coil section 3 way valve with actuator External direct expansion coil section 3 damper mixing box section Damper connection lever Adjusting damper On/off damper actuator External umidi cation/adiabatic cooling section Solenoid valve Round adapter for circular duct Flexible joint Roof cover External hood Supports H=180 mm Room hygrostat Ductable hygrostat Differential pressure transducer Ductable CO2 transducer INTERNAL RKE BF SKW SKE SAF V33 SED MS3 LCS SKR SSE HCP VSA BCC GAT TPR CFA PD2 HAS HCS DPS AQS BY-PASS FOR FREE-COOLING INVERTER CONNECTION FOR CIRCULAR DUCTS HIGH AIR EFFICIENCY BAG FILTER FILTER PRESSURE SWITCH BY-PASS SERVOMOTOR HIGH EFFICIENCY COMPACT FILTER Heat recovery unit www.lmf.it 37 Q Model RKE BF Nom Max m³/h Min Nom Sound pressure level at 1 m Max dB(A) Min Full load total current A Speci c fan power 19 30 40 60 1600 2600 3400 5500 1400 1600 2200 3300 4300 6100 400 600 700 1300 2000 4000 52,0 59,0 62,0 63,0 67,0 64,0 53,0 60,0 63,0 62,0 65,0 65,0 51,0 58,0 61,0 64,0 68,0 63,0 12,0 12,6 15,6 16,0 16,4 33,2 2050 1819 1571 1956 1528 1567 IP 44 IP 44 IP 44 IP 44 IP 20 F F F F F F Motor insulation class Electrical power supply 14 1100 IP 44 W/(m³/s) Motor protection rating V-Ph-Hz 230-1-50 Nom Ef ciency (1) 55,9 50,7 50,1 53,5 53,5 52,8 51,4 48,5 48,8 51,9 52,0 52,1 Min 60,2 54,2 54,8 57,9 56,9 54,8 Nom 3,5 4,6 6,7 11,6 15,1 24,1 Max Recovered heating capacity (1) Max % kW Min Nom Supply temperature (1) Max °C Min 6,0 6,4 8,8 14,2 18,6 26,4 2,0 2,7 3,2 6,3 9,5 18,2 7,7 6,5 6,4 7,1 7,1 7,0 6,7 6,0 5,9 6,8 6,8 6,8 8,7 7,3 7,4 8,1 7,9 7,4 High ef ciency lters FC6 Pressure drop Max Pa 21 35 42 40 39 31 FT6 Pressure drop Max Pa - 111 141 137 158 163 FT7 Pressure drop Max Pa - 131 165 157 192 168 FT8 Pressure drop Max Pa - 164 198 189 217 204 (1) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH Q Max fan speed air performances RKE BF 10 500 External Static Pressure (Pa) RKE BF Air ow 10 750 51,0 400 52,0 300 200 100 53,0 FC6 G4 0 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Air ow (m³/h) 38 Heat recovery unit www.lmf.it RKE BF 14 500 58,0 450 FC6+FT7 FC6+FT8 RKE BF External Static Pressure (Pa) 400 350 59,0 300 250 200 150 100 60,0 G4 50 FC6 0 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 Air ow (m³/h) RKE BF 19 600 G4 FC6 External Static Pressure (Pa) 500 61,0 FC6+FT7 FC6+FT8 400 62,0 300 200 63,0 100 0 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 Air ow (m³/h) RKE BF 30 700 G4 FC6 64,0 600 External Static Pressure (Pa) FC6+FT7 FC6+FT8 500 400 300 63,0 200 100 62,0 0 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 Air ow (m³/h) Heat recovery unit www.lmf.it 39 RKE BF 40 800 External Static Pressure (Pa) G4 FC6 68,0 FC6+FT7 600 FC6+FT8 500 67,0 400 300 200 100 65,0 0 1900 2100 2300 2500 2700 2900 3100 3300 3500 3700 3900 4100 4300 Air ow (m³/h) RKE BF 60 400 G4 350 63,0 FC6 External Static Pressure (Pa) RKE BF 700 300 250 FC6+FT7 200 FC6+FT8 64,0 150 100 65,0 50 0 3900 4100 4300 4500 4700 4900 5100 5300 5500 5700 5900 6100 6300 Air ow (m³/h) 40 Heat recovery unit www.lmf.it Q Controls Multifunction electronic control RQU RKE BF It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control or continuous control, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater and mixing box), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories SKW internal water heating coil SKE pre or post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V MS3 3 damper mixing box SSE on/off spring actuator for damper AQS ductable CO2 transducer DPS ductable differential pressure transducer, enables constant pressure ow VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat SS P P SS SS TR TM SS SV SV Heat recovery unit www.lmf.it 41 UTW-REC UTW REC Efficiency >50% INSIDE PARTIAL OUTSIDE High air ow heat recovery unit from 2.000 to 19.000 m³/h Q General features UTW-REC are high air ow rate units for oor installation, complete with cross ow aluminum plated cross ow heat exchanger. Suitable for commercial and industrial plants, it offers a real energy saving in forced ventilation plants; the heat recovery transfers more than 50% of heat which otherwise would be lost with air exhaust. These units may be integrated with traditional heating and cooling systems (such as fan-coils, water heaters, etc.) and can operate both in summer and winter seasons. UTW-REC series consists of 8 models, with 2000 m³/h to 19000 m³/h and include a wide range of Accessories; they allow a complete series of air treatments which permit an adaptation for a large variety of applications. UTW-REC units are available in the following base versions: UTW-REC basic unit with return fan, G4 lter on the fresh air, heat recovery, supply fan UTW-REC+2ST unit with return fan, G4 lter on the fresh air, heat recovery, supply fan, damper on the fresh air side, damper on the exhaust air side. UTW-REC+3ST unit with return fan, G4 lter on the fresh air, heat recovery, supply fan, damper on the fresh air side, damper on the exhaust air side, mixing damper. Q Mechanical features The frame is made from steel pro les and the panels are sandwich type, internally insulated with sound and thermalproof material (20 mm thick. for 022 to 110 model, 25 mm thick. for 145 and 198 models). The panels are prepainted steel type and supplied with gripping seals xed to the frame by steel screws, while the inspection panels are supplied with ¼ turn safety closure. The units stand on solid galvanized steel feet support, designed for allowing the possibility to securely transport or transfer the unit around the location. The fan are double inlet forward curved centrifugal type and electric motors are 3-phase single or twin polarity type; the fan-motor group is put on a robust galvanized steel support with rubber antivibrators . The base ltering section, on the fresh air side, is composed of G4 ef ciency class synthetic cell lter; G4 lter on the return side in an option; as an option, F7 ef ciency class rigid bag lter section. The water heating-cooling coils are copper tubes and aluminum ns type; the electric heaters are composed of armoured elements mounted in a metallic frame, complete with connection board and safety thermostat. 42 Heat recovery unit www.lmf.it Q Accessories ELECTRIC SBCE SBC2E SBC3E SBC2 V32 SBC4 V34 V36 ST SSE PF PF6 TS TS8 F9 class rigid bag lter section Prearranged steam humidi er section Adiabatic humidi cation section Solenoid valve Sound attenuator section on supply Sound attenuator section on return Fixed ns air intake grille Supply plenum section Adjustable nned supply diffuser Roof cover Air lter pressure switch Room hygrostat Ductable hygrostat Multifunction electronic control Multifunction electronic control for 2 speed motors TS9 UV UP VSA SSM SSR GAS PMA BRM CPP PSTD HAS HCS RQU RQ2 MOTOR ON STEEL BELT ADJUSTER FRAME AND INSULATED SANDWICH PANELS EXTREMELY EASY INTERNAL COMPONENTS ACCESS AND FAN MAINTENANCE SECTION MOUNTED ON RUBBER ANTIVIBRATING FILTER’S EXTRACTION FROM SIDE CROSS FLOW HEAT RECOVERY Heat recovery unit www.lmf.it 43 UTW-REC 1 step post electric heater section 2 step post electric heater section 3 step post electric heater section 2 rows water coil section 3 way valve with actuator 4 rows water coil section 4 rows 3 way valve with actuator 6 rows 3 way valve with actuator Adjusting damper On/off damper actuator G4 class plain lter on return F6 class compact lter on return F7 class rigid bag lter section F8 class rigid bag lter section Q Model UTW REC UTW-REC Air ow External static pressure Sound pressure level at 1 m Full load total power input Full load total current 022 033 055 066 088 110 145 198 m3/h 2000 3100 4400 5700 8000 10000 12500 15000 Pa 150 150 200 200 200 200 200 200 dB(A) 72 75 77 77 75 77 73 74 kW 1,10 2,20 3,00 4,40 4,40 6,00 8,00 8,00 3,06 5,20 6,80 9,68 9,68 12,6 16,2 16,2 Motor protection rating IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 Motor insulation class F F F F F F F F A Electrical power supply V-Ph-Hz 400-3+N-50 Ef ciency (1) % 56,7 54,4 50,8 50,7 59,0 57,2 56,5 64,8 Recovered heating capacity (1) kW 9,40 14,0 18,6 24,0 39,2 47,5 58,8 80,8 Supply temperature (1) °C 7,9 7,3 6,5 6,5 8,4 8,0 7,8 9,7 2 2 2 2 2 2 2 2 5,60 9,70 11,0 15,3 24,0 32,2 38,7 54,1 Water coil accessory section SBC2 Rows Total cooling capacity (2) kW Sensible cooling capacity (2) kW 4,76 8,25 9,35 13,0 20,4 27,4 32,9 46,0 Water ow rate (2) m3/h 0,96 1,67 1,89 2,63 4,13 5,54 6,66 9,31 Water pressure drop (2) kPa 8 26 6 7 14 14 14 39 Heating capacity (3) kW 16,1 23,7 32,9 41,7 61,9 80,9 106 128 Water ow rate (3) m3/h 1,38 2,04 2,83 3,59 5,32 6,96 9,12 11,0 Water pressure drop (3) kPa 12 31 10 10 19 18 34 44 4 4 4 4 4 4 4 4 Total cooling capacity (2) kW 12,8 20,8 29,3 37,5 52,8 62,3 76,5 97,4 Sensible cooling capacity (2) kW 10,2 16,6 23,4 30,0 42,2 49,8 61,2 77,9 Water ow rate (2) m3/h 2,20 3,58 5,04 6,45 9,08 10,7 13,2 16,8 Water pressure drop (2) kPa 22 64 73 41 54 13 20 29 Heating capacity (3) kW 13,3 21,0 29,6 37,1 51,3 62,3 76,5 97,4 Water ow rate (3) m3/h 1,14 1,81 2,55 3,19 4,41 5,36 6,58 8,38 Water pressure drop (3) kPa 23 65 74 40 51 13 20 29 1 1 1 1 1 1 1 1 kW 3,00 4,00 5,00 4,50 7,00 6,70 8,40 10,0 °C 4,4 3,8 3,3 2,3 2,6 2,0 2,0 2,0 2 2 2 2 2 2 2 2 kW 6,00 8,00 10,0 9,00 14,0 13,4 16,8 20,0 °C 8,8 7,6 6,7 4,6 5,1 3,9 4,0 3,9 3 3 3 3 3 3 3 3 kW 9,00 12,0 15,0 13,5 21,0 20,1 25,2 30,0 °C 13,2 11,4 10,0 7,0 7,7 5,9 5,9 5,9 Water coil accessory section SBC24 Rows Electric post-heating accessory Stages Heating capacity SBCE T air side Stages Heating capacity SBC2E T air side Stages Heating capacity T air side Electrical power supply SBC3E V-Ph-Hz 400-3+N-50 (1) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C outlet 12°C (3) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH, water inlet 70°C outlet 60°C 44 Heat recovery unit www.lmf.it Q Dimensions and weight X1 UTW-REC Y1 X1 X2 A1 Ø 20 90 Y1 A X1 A2 H M90° A L3 A W UTW REC 022 033 055 066 088 110 145 198 W mm 850 1030 1240 1240 1530 1530 1850 2100 A mm 570 570 630 750 870 1110 1180 1320 L3 mm 1140 1140 1260 1390 1540 1780 1890 2030 H mm 1140 1140 1260 1390 1540 1780 1890 2030 Ø SBC2 mm 1” 1” 1” 1” 1” 1¼ 1¼ 2” Ø SBC4 mm 1” 1” 1” 1” 1¼ 2” 2” 2” X1 mm 240 300 340 400 480 560 480 560 Y1 mm 270 270 290 350 410 480 410 480 X2 mm - - - - - - 390 460 A1 mm 790 970 1180 1180 1470 1470 1770 2020 A2 mm 510 510 570 690 810 1050 1100 1240 L1 mm 570 570 570 570 570 570 570 570 L2 mm 570 570 630 750 870 1110 1180 1320 L4 mm 1080 1080 1080 1080 1080 1620 1620 1620 P mm 410 410 410 410 410 410 410 510 Q mm 600 800 900 1000 1200 1300 1700 1900 R mm 210 210 210 310 310 410 510 510 S mm 780 960 1170 1170 1460 1460 1600 1900 RxS RxS SSR TS SBC2-4 UP UV SBCE L1 L1 L2 L2 L1 SSM PMA L4 L1 PF L4 A L3 A Heat recovery unit www.lmf.it 45 UTW-REC Q Typical composition UTW-REC 2ST TS SBC2 Unit complete with: Return and Fresh Air damper, F7 rigid bag lter section, 2-4 row water cooling-heating section UTW-REC 3ST PF TS SBC2 SSM Unit complete with: Return, Fresh Air and Mixing damper, return lter, F7 rigid bag lter section, 2-4 row water cooling-heating section sound attenuator UTW-REC 3ST PF SBCE Unit complete with: Return, Fresh Air and Mixing damper, return lter, Electric heater section UTW-REC 3ST TS SBC4 SBCE SSR SSM Unit complete with: Return, Fresh Air and Mixing damper, F7 rigid bag lter section, 4 row water cooling-heating, electric heater section, section sound attenuator on return and supply 46 Heat recovery unit www.lmf.it Q Controls Multifunction electronic control RQU UTW-REC It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 1/2 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, winter humidi cation, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater and mixing box), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories V3x 3 way valve with modulating 0-10V actuator 24V SSE on/off spring actuator for damper PSTD air lter pressure switch VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat Heat recovery unit www.lmf.it 47 RKH Efficiency >70% H V INSIDE PARTIAL OUTSIDE RKH High ef ciency heat recovery unit from 400 to 4.700 m³/h Q General features RKH heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants, by using an aluminum plated cross ow heat exchanger, able to transfer more than 70% of heat which otherwise would be lost with air exhaust. These units may be integrated with traditional heating and cooling systems (such as fan-coils, water heaters, etc.) and can operate both in summer and winter seasons. RKE series consists of 5 models, with air ow rate from 400 m³/h to 4700 m³/h; all the units are particularly suitable for false ceiling installation and may be appropriately ducted allowing air supply and air suction directly in the room. RKE units are available in the following base versions: RKH horizontal unit; RKH/V vertical unit. Q Mechanical features Fully removable panels (sandwich type). Acoustic and thermal panel insulation (thickness 20 mm). High ef ciency aluminum plated heat recovery - EUROVENT certi ed - with air ows separated by special seals. G4 ef ciency class air lters, easily removable everywhere (bottom, side, top) allowing their periodic cleaning; as an option, F6-F7-F8 ef ciency class compact lters. Fans mounted on a easy removable support. Double inlet centrifugal fans, with multi-speed direct driven motor. The unit is complete of electrical terminal box tted with relay board, to aid the electrical connections and fan control. Galvanized steel condensate drain tray, with discharge from the bottom. 48 Heat recovery unit www.lmf.it Q Accessories External hood Supports H=180 mm Inverter driven fan motors Fan speed control for DDE Air lter pressure switch Room hygrostat Ductable hygrostat 3 step fan speed control Control panel Remotable temperature sensor for PCR Antifreeze thermostat Electronic control Multifunction electronic control Differential pressure transducer Ductable CO2 transducer Air quality control system SKE SAF V33 CDM SED SKR SSE FC6 FC7 FC8 HCP VSA BCC GAT TPR THE CFA PD2 DDE RDE PSTD HAS HCS CVU PCR NTC TEG LCE RQU DPS AQS KAQ RKH Pre or post electric heater External water cooling coil section 3 way valve with actuator External by-pass for free-cooling External direct expansion coil section Adjusting damper On/off damper actuator F6 class compact lter F7 class compact lter F8 class compact lter External umidi cation/adiabatic cooling section Solenoid valve Round adapter for circular duct Flexible joint Roof cover BEST POSSIBILITY OF INSPECTION, MAINTENANCE AND REPLACEMENT OF ALL THE INTERNAL COMPONENTS, ALSO IF THE UNIT IS ALREADY INSTALLED CEILING FIXING SYSTEM OF THE UNIT THE ELECTRIC CONNECTION BOX WITH RELAYS BOARD FOR LOAD POWER MANA- ELECTRIC BOARD WITH GING RELAYS VERY HIGH EFFICIENCY ALUMINUM CROSS FLOW EXCHANGER DIRECT DRIVEN 3 SPEED FAN-MOTOR Heat recovery unit www.lmf.it 49 Q Model RKH Max Air ow Med m³/h RKH Min Max External Static Pressure Sound pressure level at 1 m Med Pa 19 25 30 40 60 700 1400 2300 3200 4000 660 1270 2000 - - 610 1030 1800 2600 3050 245 251 260 283 210 221 203 227 - - Min 186 114 174 181 121 Max 52,0 55,0 56,0 59,0 62,0 50,0 53,0 54,0 - - 45,0 48,0 49,0 52,0 55,0 Med dB(A) Min Full load total current A 6,00 6,20 11,4 6,60 6,60 W/(m³/s) 2321 1182 1225 1085 1136 Fan speeds n° 3 3 3 2 2 Poles n° Speci c fan power Max Motor protection rating Motor insulation class Med % 4 4 IP 55 IP 55 F F F F 230-1-50 400-3+N-50 71,5 72,7 72,7 72,0 71,9 71,7 73,1 73,3 - - Min 72,1 74,1 73,8 73,0 73,2 Max 4,20 8,50 13,9 19,2 23,9 3,90 7,70 12,2 - - 3,70 6,30 11,0 15,8 18,6 Med kW Min Max Supply temperature (1) 4 IP 55 V-Ph-Hz Max Recovered heating capacity (1) 4 IP 55 F Electrical power supply Ef ciency (1) 4 IP 55 Med °C Min 11,2 11,5 11,5 11,3 11,3 11,3 11,6 11,6 - - 11,4 11,8 11,7 11,5 11,6 Water cooling accessory SAF Rows Air pressure drop Max Pa 3 3 3 3 3 35 48 57 72 60 Total cooling capacity (2) Max kW 5,8 11,4 15,3 20,8 26,2 Sensible cooling capacity (2) Max kW 3,05 6,01 8,4 11,4 14,4 Supply temperature (2) Max °C 14,9 15,1 17,0 17,3 17,2 Water ow rate (2) Max m³/h 0,99 1,96 2,63 3,58 4,51 Water pressure drop (2) Max kPa 3 11 19 23 10 1 1 1 1 1 kW 3,00 4,50 9,00 12,0 12,0 °C 12,6 9,5 11,5 11,0 8,8 Pa 3 3 7 7 8 51 64 50 Electric pre or post-heating accessory SKE Stages Heating capacity T air side Max Pressure drop Max Electrical power supply V-Ph-Hz 400-3+N-50 High ef ciency lters FC6 Pressure drop Max Pa 33 36 FC7 Pressure drop Max Pa 77 87 121 152 119 FC8 Pressure drop Max Pa 106 120 168 210 165 mm 315 355 400 450 600 Round adapter for circular duct BCC Diameter (1) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C outlet 12°C 50 Heat recovery unit www.lmf.it Q Max fan speed air performances 500 60 450 External Static Pressure (Pa) 400 350 25 19 300 59,0 59,0 59,0 RKH 30 40 57,0 56,0 59,0 55,0 52,0 250 56,0 62,0 200 150 62,0 56,0 100 56,0 50 53,0 58,0 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Air ow (m³/h) Q Dimensions and weight RKH 19 25 30 40 60 A mm 1450 1700 1700 1700 1900 B mm 900 1230 1230 1230 1450 C mm 470 490 530 630 755 L mm 240 306 339 339 403 H mm 270 270 297 297 350 L1 mm 337 502 502 502 615 H1 mm 327 347 387 487 615 Weight kg 110 155 170 200 300 Horizontal Vertical Heat recovery unit www.lmf.it 51 Q Controls RKH Speed control CVU It is composed of a 2/3 step fan speed control (min/med/max air speed) and a manual off/ cooling/heating switch, capable of connecting an antifreeze thermostat (accessory TEG) that can stop the unit in heating mode. Accessories TEG Antifreeze thermostat Control Panel PCR This digital controller is intended for temperature regulation in environments equipped with heat recovery unit or air conditioning unit. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the control panel internal sensor or with an external one (accessory NTC). The control panel is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) and/or electric heater; moreover it includes a manual or automatic heating/cooling changeover, an economy function to reduce power consumption (it allows to temporary set an energy saving mode through a reduction of the actual set point temperature by a step when in heating mode, or increasing it by the same step when in cooling mode), and clogged lter alarm by setting the time-to-maintenance. This device can drive in a proportional way both valves and fan in order to control room temperature with the highest comfort and energy saving, following a proportional band for fan and proportional and integral for valves: the regulator will drive this valve through power pulses with one second resolution in a way that its stem will reach the position needed for the regulation, thus performing a modulation. The regulator, as soon as power is rst applied, and before it starts the actual regulation, will perform a stem position re-synchronization cycle, which is obtained by closing the valve for a time which is 150% of the value stored as nominal opening time. This cycle will be periodically repeated in order to recover possible positioning errors which might be accumulated during time. Accessories SKW SKE SAF V33 NTC TEG SSE internal water heating coil post heating electric heater external water cooling/heating coil 3 way valve with 3 points actuator 230V remotable temperature sensor for PCR antifreeze thermostat (it can be connected by an electro mechanic wiring thus no alarm is displayed on control panel) on/off damper spring actuator (only in combination with TEG accessory, by an electro mechanic wiring) Electronic control LCE It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with a supply air sensor or with the remote control panel internal sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric heater and free-cooling/freeheating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF, sensors diagnostic and integrated scheduling clock with four programs for each day of the week. 52 Heat recovery unit www.lmf.it Accessories SKW SKE SAF V33 CDM PSTD internal water heating coil post heating electric heater external water cooling/heating coil 3 way valve with 3 points actuator 230V external by-pass section for free-cooling air lter pressure switch RKH SS P P SS SS TR TM SS SV SV Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control or continuous control with DDE-DDB, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater and mixing box), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories SKW internal water heating coil SKE pre or post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V CDM external by-pass section for free-cooling MS3 3 damper mixing box SSE on/off spring actuator for damper PSTD air lter pressure switch DDE inverter driven fan motors AQS ductable CO2 transducer (only with DDE) DPS ductable differential pressure transducer (only with DDE) enables constant pressure ow VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat Air ow control KAQ It is composed of a complete air quality control system, non related to the main control chosen, but has to be installed to accessory DDE: it includes a ductable CO2 transducer, an electronic control with analog output and a 24V transformer, all fully wired in an electrical panel onboard. KAQ Heat recovery unit www.lmf.it 53 RKS RKS Efficiency Plug&Play >90% H V EC FANS INSIDE PARTIAL OUTSIDE 90% heat recovery unit plug and play from 100 to 2.300 m³/h Q General features RKS heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants, by using an aluminum plated counter- ow heat exchanger, able to transfer more than 90% of heat which otherwise would be lost with air exhaust. These units may be integrated with traditional heating and cooling systems (such as fan-coils, water heaters, etc.) and can operate both in summer and winter seasons. RKS series consists of 4 models, with air ow rate from 100 m³/h to 2300 m³/h; all the units are particularly suitable for false ceiling installation and may be appropriately ducted allowing air supply and air suction directly in the room. RKE units are available in the following base versions: RKS horizontal unit RKS/V vertical unit Q Mechanical features Fully removable panels (sandwich type). Acoustic and thermal panel insulation (thickness 20 mm). High ef ciency aluminum plated heat recovery - EUROVENT certi ed - with air ows separated by special seals. G4 ef ciency class air lters, easily removable everywhere (bottom, side, top) allowing their periodic cleaning; as an option, F6-F7-F8 ef ciency class compact lters. Fans mounted on a easy removable support. Double inlet centrifugal fans, with high ef ciency brushless direct driven motor. The unit is complete of on-board electronic control panel. Galvanized steel condensate drain tray, with discharge from the bottom side. 54 Heat recovery unit www.lmf.it Q Accessories Pre or post electric heater External water cooling coil section 3 way valve with actuator External direct expansion coil section Internal by-pass for free-cooling Adjusting damper On/off damper actuator F6 class compact lter F7 class compact lter F8 class compact lter External umidi cation/adiabatic cooling section Solenoid valve Round adapter for circular duct Flexible joint Roof cover External hood Supports H=180 mm Air lter pressure switch Room hygrostat Ductable hygrostat Differential pressure transducer Ductable CO2 transducer EC RKS SKE SAF V33 SED BPL SKR SSE FC6 FC7 FC8 HCP VSA BCC GAT TPR CFA PD2 PSTD HAS HCS DPS AQS BRUSHLESS FAN MOTOR VERY HIGH EFFICIENCY COUNTER-FLOW HEAT EXCHANGER COMPACT FILTERS EASILY REMOVABLE THE UNIT IS ALWAYS EQUIPPED WITH THE INSTALLATION KIT THE COUNTER-FLOW PRINCIPLE ALLOWS A HEAT RECOVERY WITH EFFICIENCY >90% Heat recovery unit www.lmf.it 55 Q Model RKS Nom Air ow Max m³/h RKS Min Nom External Static Pressure Sound pressure level at 1 m Max Pa 10 14 25 40 500 1000 1500 2000 750 1500 2100 2300 100 500 750 1000 185 225 235 270 67 104 135 65 Min 376 363 350 467 Nom 52,0 64,0 63,0 62,0 53,0 64,0 62,0 61,0 52,0 64,0 63,0 62,0 Max dB(A) Min Full load total current A 3,20 6,40 6,40 6,40 Full load total power input W 720 1500 1500 1500 W/(m3/s) 588 1261 1203 1284 Motor protection rating IP 32 IP 54 IP 54 IP 54 Motor insulation class F F F F 90,0 90,1 90,1 90,0 88,6 88,7 88,9 89,5 95,3 92,5 92,5 92,4 4,10 8,20 12,3 16,3 6,00 12,1 16,9 18,7 Speci c fan power Electrical power supply V-Ph-Hz Nom Ef ciency (1) Max % Min Nom Recovered heating capacity (1) Supply temperature (1) Max kW 230-1-50 Min 0,90 4,20 6,30 8,40 Nom 17,3 17,3 17,3 17,3 16,9 16,9 17,0 17,2 18,7 18,0 18,0 18,0 3 3 3 3 Max °C Min Water cooling accessory SAF Rows Air pressure drop Nom Pa 40 33 33 30 Total cooling capacity (2) Nom kW 4,00 6,70 12,3 16,1 Sensible cooling capacity (2) Nom kW 1,92 3,22 5,90 7,73 Supply temperature (2) Nom °C 15,9 17,7 15,6 15,8 Water ow rate (2) Nom m³/h 0,69 1,15 2,12 2,77 Water pressure drop (2) Nom kPa 8 6 13 14 1 1 1 1 kW 0,50 1,00 1,50 2,00 Nom °C 2,9 2,9 2,9 2,9 Nom Pa 8 8 7 10 Electric pre or post-heating accessory SKE Stages Heating capacity T air side Pressure drop Electrical power supply V-Ph-Hz 230-1-50 High ef ciency lters FC6 Pressure drop Nom Pa 9 41 32 31 FC7 Pressure drop Nom Pa 46 97 76 74 FC8 Pressure drop Nom Pa 63 135 105 102 mm 315 315 355 450 Round adapter for circular duct BCC Diameter (1) Outdoor air -7°C 80% RH, ambient air 20°C 55% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C 56 Heat recovery unit www.lmf.it Q Max fan speed air performances 500 40 450 10 64,0 52,0 25 14 350 RKS External Static Pressure (Pa) 400 63,0 300 62,0 63,0 250 64,0 52,0 200 51,0 150 100 50,0 62,0 50,0 64,0 45,0 61,0 50 50,0 49,0 45,0 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Air ow (m³/h) Horizontal Vertical Q Dimensions and weight RKS 10 14 25 40 A mm 1150 1450 1700 1700 B mm 860 1230 1230 1230 C mm 385 410 490 630 L mm 226 235 235 235 H mm 112 210 210 210 L1 mm 330 331 502 502 H1 mm 267 268 347 487 Weight kg 75 120 175 220 Heat recovery unit www.lmf.it 57 Q Controls RKS Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 3 step fan speed control or continuous control, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories 58 SKE pre or post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V BPL internal by-pass for free-cooling SSE on/off spring actuator for damper PSTD air lter pressure switch AQS ductable CO2 transducer DPS ductable differential pressure transducer, enables constant pressure ow VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat Heat recovery unit www.lmf.it SS P P RKS SS SS TR TM SS SV SV Heat recovery unit www.lmf.it 59 RKS 3V RKS 3V Efficiency >90% H V INSIDE PARTIAL OUTSIDE 90% heat recovery unit from 100 to 2.900 m³/h Q General features RKS 3V heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants, by using an aluminum plated counter- ow heat exchanger, able to transfer more than 90% of heat which otherwise would be lost with air exhaust. These units may be integrated with traditional heating and cooling systems (such as fan-coils, water heaters, etc.) and can operate both in summer and winter seasons. RKS 3V series consists of 4 models, with air ow rate from 100 m³/h to 2900 m³/h; all the units are particularly suitable for false ceiling installation and may be appropriately ducted allowing air supply and air suction directly in the room. RKE units are available in the following base versions: RKS 3V horizontal unit RKS 3V/V vertical unit. Q Mechanical features Fully removable panels (sandwich type). Acoustic and thermal panel insulation (thickness 20 mm). High ef ciency aluminum plated heat recovery - EUROVENT certi ed - with air ows separated by special seals. G4 ef ciency class air lters, easily removable everywhere (bottom, side, top) allowing their periodic cleaning; as an option, F6-F7-F8 ef ciency class compact lters. Fans mounted on a easy removable support. Double inlet centrifugal fans, with multi-speed direct driven motor. The unit is complete of electrical terminal box tted with relay board, to aid the electrical connections and fan control. Galvanized steel condensate drain tray, with discharge from the bottom side. 60 Heat recovery unit www.lmf.it Q Accessories Supports H=180 mm Brushless fan motors Fan speed control for DDE Air lter pressure switch Room hygrostat Ductable hygrostat 3 step fan speed control Control panel Remotable temperature sensor for PCR Antifreeze thermostat Electronic control Multifunction electronic control* Differential pressure transducer Ductable CO2 transducer Air quality control system SKE SAF V33 BPL SED SKR SSE FC6 FC7 FC8 HCP VSA BCC GAT TPR CFA PD2 DDB RDE PSTD HAS HCS CVU PCR NTC TEG LCE RQU DPS AQS KAQ RKS 3V Pre or post electric heater External water cooling coil section 3 way valve with actuator Internal by-pass for free-cooling External direct expansion coil section Adjusting damper On/off damper actuator F6 class compact lter F7 class compact lter F8 class compact lter External umidi cation/adiabatic cooling section Solenoid valve Round adapter for circular duct Flexible joint Roof cover External hood * (for model 10 only in combination with DDB) DIRECT DRIVEN 3 SPEED FAN-MOTOR VERY HIGH EFFICIENCY COUNTER-FLOW HEAT EXCHANGER COMPACT FILTERS EASILY REMOVABLE THE UNIT IS ALWAYS EQUIPPED WITH THE INSTALLATION KIT THE COUNTER-FLOW PRINCIPLE ALLOWS A HEAT RECOVERY WITH EFFICIENCY >90% ELECTRICAL TERMINAL BOX Heat recovery unit www.lmf.it 61 Q Model RKS 3V Max RKS 3V Air ow External Static Pressure Sound pressure level at 1 m 14 25 40 1000 1500 2000 485 950 1430 1800 Min 440 810 1330 1600 Max 85 130 150 215 175 Med m³/h 10 500 60 125 135 Min 55 75 125 165 Max 52,0 55,0 60,0 59,0 50,0 54,0 59,0 56,0 45,0 48,0 56,0 54,0 Med Med Pa dB(A) Min Full load total current A 3,00 6,20 14,2 11,4 Full load total power input W 720 1500 3300 2800 Speci c fan power W/(m³/s) 1557 1457 1459 1395 Fan speeds n° 3 3 3 3 Poles n° 4 4 4 4 IP 44 IP 55 IP 55 IP 55 F F F F Motor protection rating Motor insulation class Electrical power supply V-Ph-Hz 90,0 90,1 90,1 90,0 90,1 90,3 90,3 90,4 Min 90,5 90,9 90,5 90,8 Max 4,10 8,20 12,3 16,3 4,00 7,80 11,7 14,8 Min 3,60 6,70 10,9 13,2 Max 17,3 17,3 17,3 17,3 17,3 17,4 17,4 17,4 17,4 17,5 17,4 17,5 Max Ef ciency (1) Recovered heating capacity (1) Supply temperature (1) 230-1-50 Med Med Med % kW °C Min Water cooling accessory SAF Rows 3 3 3 3 Air pressure drop Max Pa 40 33 33 30 Total cooling capacity (2) Max kW 4,00 6,70 12,3 16,1 Sensible cooling capacity (2) Max kW 1,92 3,22 5,90 7,73 Supply temperature (2) Max °C 15,9 17,7 15,6 15,8 Water ow rate (2) Max m³/h 0,69 1,15 2,12 2,77 Water pressure drop (2) Max kPa 8 6 13 14 1 1 1 1 Electric pre or post-heating accessory SKE Stages Heating capacity T air side Pressure drop kW 0,50 1,00 1,50 2,00 Max °C 2,9 2,9 2,9 2,9 Max Pa 8 8 7 10 Electrical power supply V-Ph-Hz 230-1-50 High ef ciency lters FC6 Pressure drop Max Pa 19 41 32 31 FC7 Pressure drop Max Pa 46 97 76 74 FC8 Pressure drop Max Pa 63 135 105 102 mm 315 315 355 450 Round adapter for circular duct BCC Diameter (1) Outdoor air -7°C 80% RH, ambient air 20°C 55% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C outlet 12°C 62 Heat recovery unit www.lmf.it Q Max fan speed air performances 450 40 59,0 350 RKS 3V External Static Pressure (Pa) 400 59,0 300 25 60,0 14 250 55,0 10 200 59,0 52,0 60,0 150 55,0 52,0 100 50 59,0 60,0 55,0 52,0 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Air ow (m³/h) Q Dimensions and weight RKS 3V 10 14 25 40 A mm 1150 1450 1700 1700 B mm 860 1230 1230 1230 C mm 385 410 490 630 L mm 240 240 306 339 H mm 218 270 270 297 L1 mm 330 331 502 502 H1 mm 267 268 347 487 Weight kg 75 120 175 220 Horizontal Vertical Heat recovery unit www.lmf.it 63 Q Controls RKS 3V Speed control CVU It is composed of a 3 step fan speed control (min/med/max) and a manual off/cooling/heating switch with capacity to connect an antifreeze thermostat (accessory TEG) that can stop the unit in heating mode. Accessories TEG Antifreeze thermostat Control Panel PCR This digital controller is intended for temperature regulation in environments equipped with heat recovery unit or air conditioning unit. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the control panel internal sensor or with an external one (accessory NTC). The control panel is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) and/or electric heater; moreover it includes a manual or automatic heating/cooling changeover, an economy function to reduce power consumption (it allows to temporary set an energy saving mode through a reduction of the actual set point temperature by a step when in heating mode, or increasing it by the same step when in cooling mode), and clogged lter alarm by setting the time-to-maintenance. This device can drive in a proportional way both valves and fan in order to control room temperature with the highest comfort and energy saving, following a proportional band for fan and proportional and integral for valves: the regulator will drive this valve through power pulses with one second resolution in a way that its stem will reach the position needed for the regulation, thus performing a modulation. The regulator, as soon as power is rst applied, and before it starts the actual regulation, will perform a stem position re-synchronization cycle, which is obtained by closing the valve for a time which is 150% of the value stored as nominal opening time. This cycle will be periodically repeated in order to recover possible positioning errors which might be accumulated during time. Accessories SKE post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V NTC remotable temperature sensor for PCR TEG antifreeze thermostat (it can be connected by an electro mechanic wiring thus no alarm is displayed on control panel) SSE on/off damper spring actuator (only in combination with TEG accessory, by an electro mechanic wiring) Electronic control LCE It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with a supply air sensor or with the remote control panel internal sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric heater and free-cooling/freeheating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF, sensors diagnostic and integrated scheduling clock with four programs for each day of the week. 64 Heat recovery unit www.lmf.it post heating electric heater external water cooling/heating coil 3 way valve with 3 points actuator 230V internal by-pass for free-cooling air lter pressure switch RKS 3V Accessories SKE SAF V33 BPL PSTD SS P P SS SS TR TM SS SV SV Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control or continuous control with DDB, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories SKE pre or post heating electric heater SAF external water cooling/heating coil V33 3 way valve with 3 points actuator 230V BPL internal by-pass for free-cooling SSE on/off spring actuator for damper PSTD air lter pressure switch DDB brushless fan motors AQS ductable CO2 transducer (only with DDB) DPS ductable differential pressure transducer (only with DDB) enables constant pressure ow VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat Air ow control KAQ It is composed of a complete air quality control system, non related to the main control chosen, but has to be installed to accessory DDB: it includes a ductable CO2 transducer, an electronic control with analog output and a 24V transformer, all fully wired in an electrical panel onboard. KAQ Heat recovery unit www.lmf.it 65 SRS Efficiency >90% EC FANS INSIDE PARTIAL OUTSIDE SRS 90% ef ciency heat recovery unit from 1.000 to 11.500 m³/h Q General features The SRS units are designed and developed for civil, commercial or industrial buildings requiring the air renewal and very high heat recovery ef ciency at the same time so that any re-heating system is unnecessary. This type of unit meets the energy saving and pollution reduction laws and, contemporarily, makes the plants easier both for realization and management. The series, normal version SRS and thermal break frame version SRS-H, consists of six sizes, to cover 1000 ÷ 11500 m³/h air ow range, with over 90% heat recovery ef ciency. Q Mechanical features Unit frame made from double vane extruded aluminum pro les (thermal break type in H version), connected together by breglass-reinforced nylon joints. Standard support base made from continuous closed aluminum pro les and aluminum corner joints endowed with hole for lifting. Sandwich panels; RAL 9002 pre-painted external sheet metal and internal galvanized sheet metal; 42 mm nominal thickness. Class 0 mineral wool thermal and acoustic insulation. Synthetic cell lters, G4 ef ciency class on return air intake, compact F7 ef ciency class on fresh air intake, removable by side; F7 lter on return air intake also as an option. Direct driven double inlet forward curved blade fans and electronic motors provided with frequency converter. Heat recovery section composed of counter ow air-to-air recovery to provide very high ef ciency; recovery device removable by side. 66 Heat recovery unit www.lmf.it Q Accessories THE F7 COMPACT FILTER WITH PRESSURE SWITCH THE DOULE INLET FAN-MOTOR WITH FREQUENCY INVERTER AEH CCS V3M FC7 BPL SKR SSE PSTD TPR CU-A CU-E GA-A GA-E BC-A BC-E DDB RQU DPS AQS KAQ EXTREMELY SRS Pre or post electric heater External water coil section 3 way valve with actuator F7 class compact lter Internal by-pass for free-cooling Adjusting damper On/off damper actuator Air lter pressure switch Roof cover Fresh air side external hood Exhaust air side external hood Fresh air side exible joint Exhaust air side exible joint Round adapter for circular duct on fresh air side Round adapter for circular duct on exhaust air side Brushless fan motors Multifunction electronic control Differential pressure transducer Ductable CO2 transducer Air quality control system EASY INTERNAL COMPONENTS ACCESS FOR MAINTENANCE THE COUNTER-FLOW PRINCIPLE ALLOWS A HEAT RECOVERY WITH EFFICIENCY >90% Heat recovery unit www.lmf.it 67 Q Model SRS Nom Max Min Nom Max Min Nom Max Min External Static Pressure Sound pressure level at 1 m m³/h Pa dB(A) Full load total current Full load total power input Speci c fan power Motor protection rating Motor insulation class Electrical power supply A kW W/(m³/s) 040 060 065 080 100 1450 2500 1000 605 116 824 51,0 47,6 51,0 14,8 2,80 3101 IP 44 F 2900 4200 2000 550 97 723 51,0 48,5 51,6 16,4 3,00 1887 IP 44 F 4400 4400 6200 7000 3000 4000 425 605 91 226 695 653 53,0 54,0 51,2 52,5 54,3 53,1 29,6 32,8 5,60 6,00 2233 2207 IP 44 IP 44 F F 230-1-50 5800 8400 5000 550 97 632 53,0 50,5 54,5 32,8 6,00 1887 IP 44 F 7600 11000 6000 570 215 682 55,0 51,6 54,1 49,2 9,00 2095 IP 44 F V-Ph-Hz Nom Ef ciency (1) % Max Recovered heating capacity (1) 90,0 90,0 90,0 88,3 88,7 88,7 91,3 91,3 91,3 90,3 90,5 90,8 23,7 35,9 35,9 47,3 62,0 kW °C Max Min Electric pre or post-heating accessory AEH Stages Heating capacity T air side Pressure drop Electrical power supply 90,0 88,7 11,8 Nom Water cooling accessory CCS Rows Air pressure drop Total cooling capacity (2) Sensible cooling capacity (2) Supply temperature (2) Water ow rate (2) Water pressure drop (2) 90,0 88,7 Min Max Supply temperature (1) 90,0 88,0 Nom Min Nom Nom Nom Nom Nom Nom Pa kW kW °C m³/h kPa Nom Nom kW °C Pa V-Ph-Hz 20,0 33,8 49,9 56,0 67,5 88,4 8,30 16,6 24,8 33,1 41,0 49,4 17,3 17,3 17,3 17,3 17,3 17,3 16,8 16,9 17,0 16,8 16,9 16,9 17,6 17,6 17,6 17,4 17,4 17,5 3 61 11,1 5,77 15,2 1,91 13 3 62 24,0 12,2 14,4 4,13 19,5 3 67 35,0 17,9 14,4 6,02 9,1 3 67 35,0 17,9 14,4 6,02 9,1 3 68 50,9 26,0 13,8 8,75 20,3 3 75 65,0 33,2 13,8 11,2 22,6 1 6,00 12,2 8 1 12,0 12,2 8 1 1 18,0 18,0 12,0 12,0 8 8 400-3+N-50 1 24,0 12,2 8 1 30,0 11,6 8 (1) Outdoor air -7°C 80% RH, ambient air 20°C 55% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C outlet 12°C Q Max fan speed air performances 900 020 51,0 800 External Static Pressure (Pa) SRS Air ow 020 040 700 51,6 060 51,0 600 100 54,1 54,3 065 53,1 080 54,5 54,0 53,0 51,0 55,0 500 53,0 400 300 51,6 52,5 200 47,6 50,5 48,5 100 51,2 0 0 2000 4000 6000 8000 10000 12000 Air ow (m³/h) 68 Heat recovery unit www.lmf.it Q Air ow / Ef ciency diagram In the chart, there are the performances at different conditions of external air, at different air volume (in percentage in comparison to the nominal air ow) Room 20°C 50% RH SRS 92 90 -7°C Ef ciency (%) 88 -5°C 86 84 0°C 82 80 5°C 78 60 70 80 90 100 110 120 130 140 150 Air ow rate (%) Q Dimensions and weight X C 100 H1 H Y A B SRS ½ W1 W ½ L 020 040 060 065 080 100 L mm 1460 1460 1460 1460 1460 1660 W mm 640 1090 1590 1590 2196 2296 H mm 1560 1560 1560 1560 1560 1760 W1 mm 560 1100 1510 1510 216 2216 H1 mm 670 670 670 670 670 770 X mm 300 335 300 335 335 335 Y mm 265 295 265 295 295 295 A mm 120 105 120 105 105 105 B mm 170 377 170 240 377 223 C mm - - 650 440 771 423 Weight kg 390 560 930 940 1070 1290 Heat recovery unit www.lmf.it 69 SRS GA-A GA-E SRS BC-A BC-E CU-A CU-E CCS 020 040 060 065 080 100 120x600x500 120x600x950 120x600x500 120x600x500 120x600x950 120x700x1000 n° 1 1 2 2 2 2 L2 x H1 x W1 150x600x500 150x600x950 150x600x500 150x600x500 150x600x950 150x700x1000 n° 1 1 2 2 2 2 L2 x H2 x W2 150x400x400 150x400x400 150x400x400 150x400x400 150x400x400 150x400x400 n° 1 1 2 2 2 3 L1 x Ø 120x500 120x400 120x500 120x500 120x400 120x600 n° 1 2 2 2 4 3 L1 x Ø 120x400 120x400 120x400 120x400 120x400 120x400 n° 1 1 2 2 2 3 L3 x H1 x W1 425x600x500 425x600x950 425x600x500 425x600x500 425x600x950 495x700x1000 n° 1 1 2 2 2 2 L4 x H2 x W2 500x400x400 500x400x400 500x400x400 500x400x400 500x400x400 500x400x400 n° 1 1 2 2 2 3 L5 x H5 840 x 750 840 x 750 840 x 750 840 x 750 840 x 750 840 x 850 CCS GA-E BC-E H2 x W2 SKR L1 x H1 x W1 AEH H5 CU-E L4 GA-A BC-A H1 x W1 SKR CU-A L5 L1 L2 L3 L1 Q Possible air ow directions Intake and outlet air ows directions can be set according to 4 possible unit con gurations (A, B, C or D). For indoor installation also, a further rotation of 90° of fan sections and/or lter sections is possible. M = supply air R = return air E 90 A = outside air A 90 M 90 M E R 90 A R B A A R R 90 E = exhaust air E M A 90 M 90 E 90 M R E A D C A R E 70 M Heat recovery unit www.lmf.it Q Controls Multifunction electronic control RQU SRS It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 3 step fan speed control or continuous control, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories CCS external water cooling/heating coil AEH pre or post heating electric heater V3M 3 way valve with 3 points actuator 230V BPL internal by-pass for free-cooling SSE on/off spring actuator for damper PSTD air lter pressure switch AQS ductable CO2 transducer DPS ductable differential pressure transducer, enables constant pressure ow SS P P SS SS TR TM SS SV SV Air ow control KAQ It is composed of a complete air quality control system, non related to the main control chosen, but has to be installed to accessory DDE: it includes a ductable CO2 transducer, an electronic control with analog output and a 24V transformer, all fully wired in an electrical panel onboard. KAQ Heat recovery unit www.lmf.it 71 SRS BF SRS BF Efficiency >90% Plug&Play EC FANS INSIDE PARTIAL OUTSIDE 90% ef ciency heat recovery unit with free cooling, plug and play da 1.000 a 11.500 m³/h Q General features The SRS units are designed and developed for civil, commercial or industrial buildings requiring the air renewal and very high heat recovery ef ciency at the same time so that any re-heating system is unnecessary. This type of unit meets the energy saving and pollution reduction laws and, contemporarily, makes the plants easier both for realization and management. The series, normal version SRS and thermal break frame version SRS-H, consists of six sizes, to cover 1000 ÷ 11500 m³/h air ow range, with over 90% heat recovery ef ciency. The SRS BF is a plug and play unit for outdoor installation, it includes: - the fresh air and exhaust external hoods - the supply and return exible joints - the roof cover - by-pass system for free-cooling - the multifunction electronic control Q Mechanical features Unit frame made from double vane extruded aluminum pro les (thermal break type in H version), connected together by breglass-reinforced nylon joints. Standard support base made from continuous closed aluminum pro les and aluminum corner joints endowed with hole for lifting. Sandwich panels; RAL 9002 pre-painted external sheet metal and internal galvanized sheet metal; 42 mm nominal thickness. Class 0 mineral wool thermal and acoustic insulation. Synthetic cell lters, G4 ef ciency class on return air intake, compact F7 ef ciency class on fresh air intake, removable by side; F7 lter on return air intake also as an option. Direct driven double inlet forward curved blade fans and electronic motors provided with frequency converter. Heat recovery section composed of counter ow air-to-air recovery to provide very high ef ciency; recovery device removable by side. 72 Heat recovery unit www.lmf.it Q Accessories AEH CCS V3M FC7 SKR SSE PSTD BC-A BC-E DDB DPS AQS SRS BF Pre or post electric heater External water coil section 3 way valve with actuator F7 class compact lter Adjusting damper On/off damper actuator Air lter pressure switch Round adapter for circular duct on fresh air side Round adapter for circular duct on exhaust air side Brushless fan motors Differential pressure transducer Ductable CO2 transducer Options included in the base version: the fresh air and exhaust external hoods, the supply and return exible joints, the roof cover, by-pass system for free-cooling, the multifunction electronic control. THE INTERNAL BY-PASS FOR FREE-COOLING ROOF COVER THE EXHAUST AIR SIDE EXTERNAL HOOD THE MULTIFUNCTION ELECTRONIC CONTROL THE FRESH AIR SIDE EXTERNAL HOOD Heat recovery unit www.lmf.it 73 Q Model SRS BF Nom Max Min Nom Max Min Nom Max Min External Static Pressure Sound pressure level at 1 m m³/h Pa dB(A) Full load total current Full load total power input Speci c fan power Motor protection rating Motor insulation class Electrical power supply A kW W/(m3/s) 040 060 065 080 100 1450 2500 1000 605 116 824 51,0 47,6 51,0 14,8 2,80 3101 IP 44 F 2900 4200 2000 550 97 723 51,0 48,5 51,6 16,4 3,00 1887 IP 44 F 5800 8400 5000 550 97 632 53,0 50,5 54,5 32,8 6,00 1887 IP 44 F 7600 11000 6000 570 215 682 55,0 51,6 54,1 49,2 9,00 2095 IP 44 F 90,0 88,0 91,3 11,8 20,0 8,30 17,3 16,8 17,6 90,0 88,7 91,3 23,7 33,8 16,6 17,3 16,9 17,6 4400 4400 6200 7000 3000 4000 425 605 91 226 695 653 53,0 54,0 51,2 52,5 54,3 53,1 29,6 32,8 5,60 6,00 2233 2207 IP 44 IP 44 F F 230-1-50 90,0 90,0 88,7 88,3 91,3 90,3 35,9 35,9 49,9 56,0 24,8 33,1 17,3 17,3 17,0 16,8 17,6 17,4 90,0 88,7 90,5 47,3 67,5 41,0 17,3 16,9 17,4 90,0 88,7 90,8 62,0 88,4 49,4 17,3 16,9 17,5 3 61 11,1 5,77 15,2 1,91 13 3 62 24,0 12,2 14,4 4,13 19,5 3 67 35,0 17,9 14,4 6,02 9,1 3 67 35,0 17,9 14,4 6,02 9,1 3 68 50,9 26,0 13,8 8,75 20,3 3 75 65,0 33,2 13,8 11,2 22,6 1 6,00 12,2 8 1 12,0 12,2 8 1 1 18,0 18,0 12,0 12,0 8 8 400-3+N-50 1 24,0 12,2 8 1 30,0 11,6 8 V-Ph-Hz Ef ciency (1) Recovered heating capacity (1) Supply temperature (1) Water cooling accessory CCS Rows Air pressure drop Total cooling capacity (2) Sensible cooling capacity (2) Supply temperature (2) Water ow rate (2) Water pressure drop (2) Electric pre or post-heating accessory AEH Stages Heating capacity T air side Pressure drop Electrical power supply Nom Max Min Nom Max Min Nom Max Min kW Nom Nom Nom Nom Nom Nom Pa kW kW °C m³/h kPa Nom Nom kW °C Pa V-Ph-Hz % °C (1) Outdoor air -7°C 80% RH, ambient air 20°C 55% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C outlet 12°C Q Max fan speed air performances 900 020 51,0 800 External Static Pressure (Pa) SRS BF Air ow 020 040 700 51,6 060 51,0 54,3 065 53,1 600 51,0 100 54,1 080 54,5 54,0 53,0 55,0 500 53,0 400 300 51,6 52,5 200 47,6 50,5 48,5 100 51,2 0 0 2000 4000 6000 8000 10000 12000 Air ow (m³/h) 74 Heat recovery unit www.lmf.it Q Air ow / Ef ciency diagram In the chart, there are the performances at different conditions of external air, at different air volume (in percentage in comparison to the nominal air ow) SRS BF Room 20°C 50% RH 92 90 -7°C Ef ciency (%) 88 -5°C 86 84 0°C 82 80 5°C 78 60 70 80 90 100 110 120 130 140 150 Air ow rate (%) Q Controls Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 3 step fan speed control or continuous control, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories CCS external water cooling/heating coil AEH pre or post heating electric heater V3M 3 way valve with 3 points actuator 230V SSE on/off spring actuator for damper AQS ductable CO2 transducer DPS ductable differential pressure transducer, enables constant pressure ow Heat recovery unit www.lmf.it 75 TWR Efficiency >80% INSIDE PARTIAL OUTSIDE TWR Rotary high ef ciency heat recovery unit from 3.000 to 15.000 m³/h Q General features The TWR units are designed and developed for civil, commercial or industrial buildings requiring the air renewal and heat & humidity recovery at the same time so that any re-treatment system can be sized as small as possible. This type of unit meets the energy saving and pollution reduction laws and, contemporarily, makes the plants easier both for realization and management. The series consists of four sizes, to cover from 3000 to 15000 m³/h air ow range, with over 80% heat recovery ef ciency TWR units are available in the following base versions: TWR basic unit TWR r unit with recirculation damper TWR h unit with water heating coil TWR c unit with water cooling coil Q Mechanical features Unit frame made by a vane extruded aluminum pro les, connected together by breglass-reinforced nylon joints. Standard support base made from continuous closed aluminum pro les and aluminum corner joints endowed with hole for lifting. Sandwich panels, RAL 9002 precoated sheet metal outside nominal thickness. and galvanized steel sheet metal inside with 42 mm Class 0 mineral wool thermal and acoustic insulation. Synthetic cell lters, G4 ef ciency class on both air intakes; as an option, F7 soft bag lter on return air circuit and F8 on supply air circuit. High ef ciency and low noise direct driven plug-fans, impellers with welded blades and powder coated, electric motors already provided with PTC thermistor and possibly equipped with frequency converter. Heat recovery section by water resistant aluminum alloy hygroscopic thermal wheel, possibly equipped with rotor speed control. 76 Heat recovery unit www.lmf.it Q Accessories Pre or post electric heater External water heating coil section External water coil section 3 way valve with actuator Fresh air side adjusting damper Exhaust air side adjusting damper On/off damper actuator F7 class soft bag lter F8 class soft bag lter Sound attenuator section Roof cover Round adapter for circular duct External hood Flexible joint Inverter for motors Air lter pressure switch Multifunction electronic control Differential pressure transducer Ductable CO2 transducer Air quality control system TWR AEH CHS CCS V3M SKRi SKRo SSE FT7 FT8 SL TPR BC CU GA FSC PSTD RQU DPS AQS KAQ THE PLUG-FAN SECTION ALUMINUM FRAME WITH 3 WAY JOINTS THE HIGH EFFICIENCY THERMAL WHEEL ROOF COVER CONDENSATE DISCHARGE FLEXIBLE JOINT Heat recovery unit www.lmf.it 77 Q Model TWR 400 Nom TWR Air ow Sound pressure level at 1 m 900 1300 4000 6300 9000 13000 4800 7500 10500 15000 Min 3000 5000 7600 11000 Nom 696 799 842 784 250 424 580 458 Min 1049 1093 1031 1019 Nom 53 54 54 56 dB(A) 55 56 56 58 54 55 55 57 A 6,00 12,2 16,2 21,2 Max External Static Pressure 630 Max Max m³/h Pa Min Full load total current Full load total power input W 3,00 6,00 8,00 11,0 W/(m3/s) 1350 1714 1600 1523 Motor protection rating IP 55 IP 55 IP 55 IP 55 Motor insulation class F F F F Speci c fan power Electrical power supply V-Ph-Hz Nom Ef ciency (1) Recovered heating capacity (1) Supply temperature (1) Max % 80,0 80,0 78,0 78,1 82,0 83,2 82,6 82,0 44,9 70,6 101 146 52,2 81,7 115 164 Max kW Min 35,0 57,9 87,4 126 Nom 14,0 14,0 14,0 14,0 Max °C Max % 13,3 13,3 13,4 13,4 15,0 14,8 14,6 14,6 80,0 80,0 80,0 80,0 77,5 77,7 78,0 78,1 Min 83,2 82,6 82,0 82,0 Nom 10,1 15,8 22,6 32,6 Max kW Min Nom Supply temperature (2) 80,0 77,7 Min Nom Recovered cooling capacity (2) 80,0 77,5 Nom Min Ef ciency (2) 400-3+N-50 Max °C Min 11,7 18,3 25,7 36,8 7,8 13,0 19,6 28,3 27,2 27,2 27,2 27,2 27,3 27,3 27,3 27,3 27,0 27,0 27,1 27,1 0,70 Rotary heat exchanger Full load current Full load power input Electrical power supply A 3,00 3,00 3,00 kW 40,0 40,0 40,0 V-Ph-Hz 24V DC 400 230-1-50 Water post-heating accessory CHS Rows 2 2 2 2 25 26 24 26 Air pressure drop Pa Heating capacity (3) kW 34,9 54,1 74,0 107 Supply temperature (3) °C 39,5 39,0 38,0 38,1 Water ow rate (3) m³/h 3,00 4,65 6,36 9,20 Water pressure drop (3) kPa 19 15 5 7 4 4 4 4 Pa 123 129 119 127 Water cooling accessory CCS Rows Air pressure drop Total cooling capacity (4) kW 27,4 43,2 61,3 91,8 Sensible cooling capacity (4) kW 15,1 23,8 33,7 50,5 °C 16,1 16,1 16,2 15,9 Water ow rate (4) Supply temperature (4) m³/h 4,71 7,43 10,5 15,8 Water pressure drop (4) kPa 27 30 18 30 1 1 1 1 kW 18,0 24,0 36,0 54,0 °C 13,2 11,2 11,8 12,2 Pa 8 8 8 8 Electric pre or post-heating accessory AEH Stages Heating capacity T air side Pressure drop Electrical power supply V-Ph-Hz 400-3+N-50 (1) Outdoor air -10°C 90% RH, ambient air 20°C 50% RH (2) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH (3) Outdoor air -10°C 90% RH, ambient air 20°C 50% RH, water inlet 70°C outlet 60°C (4) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH, water inlet 7°C outlet 12° 78 Heat recovery unit www.lmf.it Q Max fan speed air performances 1200 55,0 400 630 54,0 55,0 1300 54,0 54,0 800 TWR External Static Pressure (Pa) 57,0 900 1000 56,0 53,0 600 56,0 58,0 56,0 400 55,0 200 0 2000 4000 6000 8000 10000 12000 14000 16000 Air ow (m³/h) Q Unit version TWR Basic unit TWR r Unit with recirculation damper TWR h Unit with water heating coil TWR c Unit with water cooling coil Heat recovery unit www.lmf.it 79 Q Dimensions and weight H1 H TWR H1 W1 Φ L TWR Φ W 400 630 900 1300 L mm 2420 2420 2870 3220 W H W1 mm mm mm 1350 1450 1270 1600 1700 1520 1900 2000 1820 2220 2320 2140 H1 mm 400 500 600 700 Ø Weight mm kg ½” 610 ½” 930 1” 1270 1” 1690 SKRi SKRo GA BC L1 x P x Q L1 x P x Q L2 x P x Q L1 x Ø N° L3 x P x Q L4 x H3 x W3 L5 x H3 x W3 L5 x H3 x W3 120 x 400 x 1270 120 x 400 x 1270 150 x 400 x 1270 120 x 400 2 300 x 400 x 1270 1080 x 675 x 1350 300 x 675 x 1350 500 x 675 x 1350 120 x 500 x 1500 120 x 500 x 1500 150 x 500 x 1500 120 x 500 2 400 x 500 x 1500 1080 x 800 x 1600 300 x 800 x 1600 500 x 800 x 1600 120 x 600 x 1800 120 x 600 x 1800 150 x 600 x 1800 120 x 500 3 400 x 600 x 1800 1080 x 950 x 1900 300 x 950 x 1900 500 x 950 x 1900 120 x 700 x 2140 120 x 700 x 2140 150 x 700 x 2140 120 x 500 4 500 x 700 x 2140 1080 x 1100 x 2220 300 x 1100 x 2220 500 x 1100 x 222 CHS CCS SL L5 L5 L4 CU SL CHS CCS SKRo PxQ FT7 GA BC FT8 CU H2 x W2 AEH H3 x W2 PxQ AEH SKRi L L1 80 L2 L1 L3 Heat recovery unit www.lmf.it Q Air ow / Ef ciency diagram Room condition 20°C 50% RH 84,0 TWR Ef ciency (%) 83,0 82,0 81,0 80,0 79,0 78,0 Air ow rate (%) 77,0 70% 80% 90% 100% 110% 120% Valid for outside temperature range 20°C to + 35°C and room temperature range +10°C to +30°C Q Controls Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (1 step fan speed control or continuous control with FSC, based on CO2 sensor AQS or pressure transducer DPS) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/ free-heating based on fresh air sensor (it stops the thermal wheel); moreover it includes a manual or automatic heating/cooling changeover, manage of recirculation damper for quick winter startup, winter humidi cation and summer adiabatic cooling, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater and modulates supply air ow), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories V3M 3 way valve with 3 points actuator 230V SSE on/off spring actuator for damper FSC inverter for plug fan motors PSTD air lter pressure switch AQS ductable CO2 transducer DPS ductable differential pressure transducer, enables constant pressure ow Air ow control KAQ It is composed of a complete air quality control system, non related to the main control chosen, but has to be installed to accessory FSC: it includes a ductable CO2 transducer, an electronic control with analog output and a 24V transformer, all fully wired in an electrical panel onboard. Heat recovery unit www.lmf.it 81 RFM RFM R410A Scroll Plug&Play Rotary HP Efficiency >50% INSIDE PARTIAL OUTSIDE Heat recovery unit with built-in heat pump system from 900 to 4.000 m³/h Q General features The new stand-alone RFM units are dedicated to the re lling of room air and its thermal treatment. They are designed and developed for satisfying four different typical needs of residential and commercial applications: 1. the renewal of room air 2. the energy saving by using a heat recovery system 3. the neutralisation of the renewal air heat loads, by a fully automatic microprocessor controlled heat pump system; in particular, the function of heat recovery upraises both cooling and heating performances, while generating very high ef ciency and assuring, therefore, very interesting money saving 4. the neutralisation of room heat loads. RFM unit works with 100% fresh air with total cooling capacity from 5,4 to 23,5kW and total heating capacity from 8,9 to 40,4kW. Q Mechanical features Prepainted frame and fully removable sandwich panels with 20 mm thickness polyethylene/polyester thermal and acoustic insulation. High ef ciency cross ow heat recovery - EUROVENT certi ed -, aluminum heat exchanger plates with supplementary sealing; stainless steel drain tray, extended to all the cooling/heating components and heat insulated, complete with water trap. G4 ef ciency class synthetic cell lters. Single speed double inlet forward curved fans, eventually matched with speed electronic regulator or supplied with built-in frequency converter motors. Heat pump refrigeration system (R410A) composed of scroll hermetic compressor, Cu-Al evaporator and condenser coils, bi ow thermostatic valve, liquid separator and receiver, 4-way valve for cycle inversion, overpressure safety valve, high and low pressure switches, bi ow freon lter and liquid indicator. Internal electrical board for supplying all the electrical powers; room, outside and frost temperature sensors. Microprocessor control for fully automatic management of room temperature, free-cooling, heating/cooling mode and defrost cycles; display for setting and for visualizing sensor and set-point temperature values, connected up to 20 m far from unit board. 82 Heat recovery unit www.lmf.it Q Accessories SKE FC6 DDE PSTD SKR SSE GAT TPR CFA PD2 RFM Pre or post electric heater F6 class compact lter Inverter driven fan motors Air lter pressure switch Adjusting damper On/off damper actuator Flexible joint Roof cover External hood Supports H=180 mm R410A THE GAS REFRIGERANT SYSTEM SIDE TECHNICAL SPACE, EXTERNAL FROM THE AIR FLOW, ALLOWS TO WORK VERY EASILY STATIC RECOVERY BY THE HIGH EFFICIENCY ALUMINUM CROSS FLOW EXCHANGER PRE-PAINTED STEEL FRAME WITH INSULATED SANDWICH PANELS OPENING SYSTEM FROM THE BOTTOM WITH A 1/4 HIGH TURN SECURITY LOCK CAPACITY G4 FILTER, THICK. Heat recovery unit www.lmf.it 98MM 83 Q Model RFM 14 19 25 30 40 50 m³/h 900 1400 2000 2600 3300 4000 External static pressure on supply Pa 225 154 187 179 211 159 External static pressure on return Pa 184 122 130 148 153 133 RFM Air ow Sound pressure level at 1 m dB(A) 55 52 59 58 58 62 A 14,6 21,6 36,3 22,6 26,9 24,8 Speci c fan power W/(m³/s) 1880 1170 1231 1177 1372 1683 Electrical power supply V-Ph-Hz Full load total current 230-1-50 400-3+N-50 Ef ciency (1) % 46,7 44,6 49,2 47,8 48,8 47,8 Recovered cooling capacity (1) W 803 1184 1888 2336 3033 3594 Compressor cooling capacity (1) W 4597 7010 10352 12705 17548 19928 Total cooling capacity (1) W 5400 8194 12240 15041 20581 23522 Available cooling capacity (1) W 1838 2678 4085 4804 6740 7521 2,80 2,57 2,60 2,86 2,94 2,78 19,7 20,1 19,7 20,3 19,7 20,2 EER (1) Supply temperature (1) °C Ef ciency (2) % 54,0 51,4 56,9 55,2 56,4 55,2 Recovered heating capacity (2) W 4015 6004 9446 11892 15463 18296 Compressor heating capacity (2) W 4860 7672 11612 14571 19629 22137 Total heating capacity (2) W 8875 13676 21058 26464 35092 40433 Available heating capacity (2) W 796 1095 3060 3094 5386 4488 6,12 5,65 5,69 5,88 6,03 5,62 °C 22,6 22,3 24,5 23,5 24,8 23,3 A 4,20 4,40 6,00 7,00 7,00 5,80 Full load total power input W 1472 1484 3288 2796 2796 5110 Poles n° 4 4 4 4 4 4 Motor protection rating IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 Motor insulation class F F F F F F COP (2) Supply temperature (2) Fans Full load total current Electrical power supply V-Ph-Hz 230-1-50 400-3--50 Compressor Refrigerant gas R410A Type Full load current Full load power input Electrical power supply rotary rotary scroll scroll scroll scroll A 8,83 15,4 22,1 10,6 14,9 16,4 W 1930 3360 4860 5630 7965 8735 V-Ph-Hz 230-1-50 400-3--50 Electric pre or post-heating accessory RES Stages Heating capacity T air side Pressure drop Electrical power supply 1 1 1 1 1 1 kW 2,50 2,50 5,00 5,00 7,00 7,00 °C 8,2 5,3 7,4 5,7 6,2 5,1 Pa 5 9 6 9 7 9 70 55 70 V-Ph-Hz 400-3+N-50 High ef ciency lters FK6 Pressure drop Pa 40 65 55 (1) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH (2) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH 84 Heat recovery unit www.lmf.it Q Dimensions and weight RFM RFM 14 19 25 30 40 50 A mm. 1450 1450 1700 1700 1900 1900 B mm. 1230 1230 1560 1560 1700 1700 C mm. 470 470 530 530 705 705 F mm. 50 50 192 182 280 280 G mm. 154 154 72 59 135 135 L mm. 235 235 303 330 335 335 H mm. 265 265 266 290 290 290 M mm. 182 182 280 254 313 313 N mm. 120 120 172 136 183 183 L1 mm. 331 331 502 502 545 545 H1 mm. 323 323 387 387 545 545 M1 mm. 417 417 412 412 450 450 Weight Kg 212 225 258 258 305 315 Q Possible installations OUTSITE Exhaust Fresh air INSIDE OUTSITE Supply Return Heat recovery unit www.lmf.it 85 Q Controls RFM It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit with builtin heat pump system; it is an easy plug and play electronic control. The device automatically controls the fan speed (1 step fan speed control or continuous control with DDE based on constant air ow algorithm) as well as the possible electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition is performed with the return air sensor, the supply air sensor before direct expansion coil and exhaust air sensor (for defrosting in heat mode). The electronic control is suitable to manage electric pre and/or post heater, automatic heating/cooling changeover, manage of external dampers, heat exchanger defrost based on exhaust air sensor (it reverses the refrigerant cycle), clogged lter alarm by pressure switch, remote ON-OFF via digital input, sensors diagnostic, electric heater post ventilation and thermal protection alarm, high and low pressure alarm, compressor and fans thermal protection, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. The display clearly shows the current working mode and ambient room temperature and desired set point is easily changeable with arrows keys; moreover there are two different level of parameters to setup and adjust every functions of the unit. A single remote control panel can connect up to four units, allowing and easy and quick setup and check from a single site. Accessories SKE pre or post heating electric heater SSE on/off spring actuator for damper PSTD air lter pressure switch DDE inverter driven fan motors The schematic diagram shows position and function of the components of the unit. TF TA = return air sensor TE = supply air sensor before direct expansion coil TF = exhaust air sensor Tsp= set point temperature 86 Heat recovery unit www.lmf.it According to Tsp-Te and Tsp-Ta values, the electronic control determines by it-self the working mode of the system, deciding cooling, heating (with or without electric heater) or defrosting mode. Heating + electric heater RFM Ventilation Heating Vent. Ventilation Ventilation Cooling When accessorizing the unit with DDE fans the available external air pressure is increased but the air ow is always maintained the nominal air ow; fans are set up in factory with constant air ow working mode. Heat recovery unit with built-in heat pump system cannot work with air ow different from nominal air ow in order to assure a good operation of the refrigerant system. Heat recovery unit www.lmf.it 87 HPX HPX R407C Scroll Plug&Play HP Efficiency >50% INSIDE PARTIAL OUTSIDE FULL OUTSIDE Heat recovery unit with builtin heat pump system from 2.000 to 14.000 m³/h Q General features The wholly self-controlled HPX units are designed and developed for civil, commercial or industrial buildings in which the air renewal and its thermal treatment are possible by one compact and ef cient solution; in fact, the use of two sequential heat recovery systems (static + dynamic) makes the unit particularly ef cient, according to the energy saving and pollution reduction laws and, contemporarily, making the plants easier both for realization and management. HPX series, T, TB and P version (and T-H, TB-H and P-H version with thermal break frame), consists of ve sizes, to cover 2000÷14000 m³/h air ow range, 0,5÷29,3 kW leftover (nominal) cooling power range and 3,2÷40,5 kW leftover (nominal) heating power range. According to the selected version, HPX unit can satisfy: the renewal of room air and the neutralization of summer and winter heat loads connected with it (T version) as above, but with built-in free-cooling system also (TB version) the neutralization of the room heat loads also, by using room recycled air partially (P version) Q Mechanical features Unit frame made in extruded aluminum pro les and sandwich panels (thick 42 mm) RAL 9002 pre-painted. Class 0 mineral wool insulation. Synthetic lter cell, G4 ef ciency class, removable by side; as option breglass rigid bag lters, F7 ef ciency class. Fan sections composed of belt driven double inlet forward curved blade fans and class F IP55 three-phase motors; rubber isolators below fan-motor group; safety micro-switches on inspection doors. High ef ciency cross ow heat recovery - EUROVENT certi ed - air to air type, made in aluminum. Second section of heat transfer by heat pump refrigeration system (R407C) essentially composed of: scroll hermetic compressor(s) evaporator/condenser coils Cu tube, Al ns bi- ux thermostatic valves cycle inversion valves low/high pressure switches high pressure manometers liquid separators and receivers Built-in electrical board complete with microprocessor for temperature control and remotable consolle for setting and for visualizing sensor and set-point temperature values, both for master module and slave module(s) (max 4 modules); prearrangement for remote supervision system by RS485 connection and MODBUS protocol. 88 Heat recovery unit www.lmf.it Q Accessories AEH F7 class rigid bag lter FTR Air lter pressure switch PSTD Liquid manometer MDL Adjusting damper SKR on/off damper actuator SSE Fresh air side external hood CU-A Exhaust air side external hood CU-E Fresh air side exible joint GA-A Exhaust air side exible joint GA-E Roof cover TPR THE HPX Pre or post electric heater SIDE TECHNICAL SPACE, ALLOWS A VERY EASY ACCESS FOR INSPECTIONS AND MAINTENANCE LARGE DOORS WITH HANDLES AND HINGES FOR CHECK OR REPLACEMENT OF ALL THE COMPONENTS THE EVAPORATOR AND CONDENSER COILS WITH TUBES AND ALUMINUM CU FINS STATIC RECOVERY BY THE HIGH EFFICIENCY ALUMINUM CROSS FLOW EXCHANGER THE THE F7 RIGID BAG FILTER FAN SECTION, MOUNTED ON RUBBER SUPPORTS ANTIVIBRATION THE AIR FILTER PRESSURE SWITCH Heat recovery unit www.lmf.it 89 Q Model HPX HPX Air ow 020 040 060 090 120 Nom m³/h 2400 4800 7000 10000 14000 Min m³/h 2000 4000 6000 8000 10000 External Static Pressure Nom Pa 350 350 350 350 350 Sound pressure level at 1 m Nom dB(A) 47 49 50 51 53 A 13,4 26,1 40,8 56,0 80,4 Full load total current Electrical power supply V-Ph-Hz 400-3+N-50 Cooling mode Ef ciency T-TB (1) Nom % 44,3 42,8 47,5 50,5 45,8 Recovered cooling capacity T-TB (1) Nom kW 2,10 4,10 6,20 9,00 11,9 Compressor cooling capacity (1) Nom kW 11,0 22,0 33,0 44,0 58,0 Total cooling capacity T-TB (1) Nom kW 13,1 26,1 39,2 53,0 69,9 Available cooling capacity T-TB (1) Nom kW 0,50 1,10 1,90 1,30 1,00 EER T-TB (1) Nom 3,47 3,45 3,49 3,52 3,53 Supply temperature T-TB (1) Nom °C 25,6 25,6 25,5 25,8 25,9 Ef ciency P (1) Nom % 53,9 48,1 45,1 43,7 43,9 Recovered cooling capacity P (1) Nom kW 0,90 2,10 3,20 4,30 5,80 Compressor cooling capacity (1) Nom kW 11,0 22,0 33,0 44,0 58,0 Total cooling capacity P (1) Nom kW 11,9 24,1 36,2 48,3 63,8 Available cooling capacity P (1) Nom kW 5,57 11,5 17,5 22,4 29,3 EER P (1) Nom 3,47 3,45 3,49 3,52 3,53 Supply temperature P (1) Nom 21,6 21,4 21,2 21,7 22,0 °C Heating mode Ef ciency T-TB (2) Nom % 51,0 49,2 54,8 56,4 51,4 Recovered heating capacity T-TB (2) Nom kW 9,90 19,5 29,2 40,5 53,1 Compressor heating capacity (2) Nom kW 12,0 24,0 36,0 48,0 64,0 Total heating capacity T-TB (2) Nom kW 21,9 43,5 65,2 88,5 117 Available heating capacity T-TB (2) Nom kW 3,20 6,10 10,0 12,0 15,1 COP T-TB (2) Nom 5,61 5,58 5,62 5,72 5,72 Supply temperature T-TB (2) Nom °C 23,9 23,7 24,2 23,5 23,2 Ef ciency P (2) Nom % 62,5 55,4 52,0 50,3 50,6 Recovered heating capacity P (2) Nom kW 4,50 9,90 15,1 20,4 27,5 Compressor heating capacity (2) Nom kW 12,0 24,0 36,0 48,0 64,0 Total heating capacity P (2) Nom kW 16,5 33,9 51,1 68,4 91,5 Available heating capacity P (2) Nom kW 7,15 15,2 23,5 30,2 40,5 COP P (2) Nom 4,23 4,35 4,41 4,41 4,47 Supply temperature P (2) Nom °C 28,8 29,3 29,9 28,9 28,5 Fans Full load total current A 5,20 9,68 16,2 22,6 31,2 Full load total power input kW 2,20 4,40 8,00 11,0 15,0 Poles n° 4 4 4 4 4 IP 55 IP 55 IP 55 IP 55 IP 55 F F F F F Motor protection rating Motor insulation class Electrical power supply V-Ph-Hz 400-3-50 Compressors R407C Refrigerant gas Type scroll Number Full load total current Full load total power input Electrical power supply 1 2 2 2 2 A 8,20 16,4 24,6 33,4 49,2 kW 4,84 9,68 14,8 20,2 29,8 V-Ph-Hz 400-3-50 Electric pre or post-heating accessory AEH Stages 1 1 1 1 1 kW 6,00 12,0 18,0 24,0 32,0 Nom °C 7,4 7,4 7,6 7,1 6,7 Nom Pa 35 35 35 35 35 132 156 Heating capacity T air side Pressure drop Electrical power supply V-Ph-Hz 400-3+N-50 High ef ciency lters FTR Pressure drop Nom Pa 160 104 112 (1) Outdoor air 32°C 50% RH, ambient air 26°C 50% RH (2) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH 90 Heat recovery unit www.lmf.it Q Dimensions and weight HPX 020 040 060 090 120 mm 2400 2400 2740 3110 3410 mm 870 1200 1500 1900 2000 C mm 1560 1560 1660 1805 2135 L mm 238 340 403 475 560 H mm 268 300 351 408 482 L1 mm 790 1120 1420 1820 1920 H1 mm 670 670 720 793 958 L2 mm 196 322 436 535 542 H2 mm 341 325 324 299 304 Weight kg 670 860 1330 1820 2150 40 L1 HPX A B 40 R F H1 C H S E H2 L2 1/2” 1/2” L A S F R E QCE = = = = = supply fresh air room air exhaust electrical board QCE B Heat recovery unit www.lmf.it 91 Q Controls HPX It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit with built-in heat pump system; it is an easy plug and play electronic control. The device automatically controls the fan (1 step fan speed control) as well as the possible electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition is performed with the return air sensor, the fresh air sensor and exhaust air sensor (for defrosting in heat mode). The electronic control is suitable to manage electric pre and/or post heater, free-cooling/free-heating by-pass damper based on fresh air sensor, automatic heating/cooling changeover, manage of external dampers, heat exchanger defrost based on exhaust air sensor (it reverses the refrigerant cycle), clogged lter alarm by pressure switch, remote ON-OFF via digital input, sensors diagnostic, electric heater post ventilation and thermal protection alarm, high and low pressure alarm, compressors and fans thermal protection, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. The display clearly shows the current working mode and ambient room temperature and desired set point is easily changeable with arrows keys; moreover there are two different level of parameters to setup and adjust every functions of the unit. A single remote control panel can connect up to four units, allowing and easy and quick setup and check from a single site. Accessories AEH pre or post heating electric heater SSE on/off spring actuator for damper PSTD air lter pressure switch The schematic diagram shows position and function of the components of the unit. TF TA = return air sensor TE = fresh air sensor TF = exhaust air sensor Tsp= set point temperature 92 Heat recovery unit www.lmf.it Risc. (100%) According to Tsp-Te and Tsp-Ta values, the electronic control determines by it-self the working mode of the system, deciding cooling, heating (with or without electric heater) or defrosting mode. HPX Heating 100% + electric heater Ventilation Risc. (50%) Vent. Ventilation Heating (100%) Heating (50%) Ventilation Cooling (50%) Free-cooling Cooling (100%) Heat recovery unit with built-in heat pump system cannot work with air ow different from nominal air ow in order to assure a good operation of the refrigerant system. Heat recovery unit www.lmf.it 93 BAW BAW-V H V INSIDE Ductable Terminal Unit BAW from 300 to 5.100 m³/h Q General features BAW series terminal units are available in 8 models with nominal air ow rate from 300 to 5100 m³/h. They are designed and developed for residential and commercial applications and they stand out for their small dimensions and easy installation like a simple fan-coil unit. Because of their small size, this series is particularly suitable for false ceiling installation, with direct or ducted supply to room. In their following base versions, they are supplied with water coil and fan: BAW horizontal ow unit; BAW/V vertical ow unit. Q Mechanical features The casing is made from aluzink sheet metal. The unit acoustic and thermal insulation is obtained by an adequate thickness of polyethylene and polyester. Heating/cooling coil is Cu tubes and Al ns type with threaded connections. Stainless steel condensate drainage. Air lters are easily removable for cleaning or replacement. Direct driven centrifugal fans with 3-speed motors; they are statically and dynamically balanced to reduce vibrations and noise. The unit is supplied with onboard electric connector (from 12 up to 18 model with relays). 94 Air handling unit www.lmf.it Q Accessories 1 step post electric heater section 2 step post electric heater section External water heating coil section 3 way valve with actuator for RQU 3 way valve with actuator for PCR 1 damper mixing box section 2 damper mixing box section On/off damper actuator G2 class plain lter section G4 class plain lter section Adiabatic humidi cation section Solenoid valve Fixed ns air intake grille Suction plenum section Return section with damper Supply plenum silenced section Supply plenum with round adapter for circular duct section Supply duct ange connection Adjustable nned supply diffuser Air lter pressure switch Room hygrostat Ductable hygrostat 3 step fan speed control Control panel Remotable temperature sensor for PCR Multifunction electronic control SRE 2SRE SRW V3 V3/S230 CM CMX SSE AF FOS UAP VSA GAS PAS SRX PAM PBC FM BRM PSTD HAS HCS CVU PCR NTC RQU BAW BRM BRM FM PBC FM UAP PAM PBC SRE SRW PAM BAW AF-FOS SRE CM-CMX Horizontal version SRW PAS SRX GAS BAW/V AF-FOS Vertical version Air handling unit www.lmf.it 95 Q Model BAW Max Air ow Med m³/h Min Max External Static Pressure Med Pa 12 13 14 15 16 17 18 1500 1600 2100 2400 3400 3800 4200 880 1250 1350 1350 1450 2200 3300 3450 760 1000 1100 700 800 1400 2700 2800 60 105 70 100 100 120 130 125 57 99 64 85 83 80 110 110 Min 51 95 64 70 59 63 100 105 Max 54,1 52,7 52,9 56,3 56,3 58,8 58,8 58,9 51,1 50,9 51,1 49,5 49,2 54,0 52,4 51,8 49,8 49,1 48,6 42,9 42,5 42,9 44,8 44,5 A 1,00 1,90 1,90 2,60 2,60 3,90 5,50 5,50 W/(m³/s) 663 658 635 831 858 723 647 819 Fan speeds n° 3 3 3 3 3 3 3 3 Poles n° 4 4 4 4 4 4 4 4 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 B B B B B B B B Sound pressure level at 1 m Med dB(A) Min Full load total current Speci c fan power Max Motor protection rating Motor insulation class Electrical power supply V-Ph-Hz Rows Max Heating capacity (1) Water ow rate (1) BAW 10 950 Water pressure drop (1) Total cooling capacity (2) Sensible cooling capacity (2) Water ow rate (2) Water pressure drop (2) 3 3 4 3 3 3 4 4 10,2 16,9 20,3 22,5 26,5 35,2 44,6 51,1 9,73 14,8 17,9 16,4 18,4 25,9 40,2 44,1 Min 8,78 12,5 15,2 9,89 11,6 18,5 34,7 37,6 Max 0,88 1,45 1,75 1,94 2,28 3,03 3,84 4,39 0,84 1,27 1,54 1,41 1,58 2,23 3,46 3,79 Min 0,76 1,08 1,31 0,85 1,00 1,59 2,98 3,23 Max 41 38 43 52 41 37 43 40 37 30 33 28 20 20 35 30 Min 30 21 24 10 8 10 26 22 Max 4,46 7,60 9,43 9,74 11,9 15,4 19,9 23,1 Med Med Med kW 230-1-50 m³/h kPa 4,23 6,70 8,38 7,21 8,40 11,4 18,0 20,1 Min 3,80 5,74 7,20 4,41 5,36 8,24 15,7 17,3 Max 3,60 6,00 7,26 7,86 9,50 12,5 15,8 18,1 3,42 5,33 6,43 5,92 6,74 9,40 14,4 15,8 Min 3,12 4,57 5,56 3,68 4,39 6,85 12,5 13,6 Max 0,77 1,31 1,62 1,68 2,05 2,65 3,42 3,97 0,73 1,15 1,44 1,24 1,44 1,96 3,10 3,46 Min 0,65 0,99 1,24 0,76 0,92 1,42 2,70 2,98 Max 32 32 38 40 33 28 34 33 29 25 30 22 17 16 28 25 24 18 22 9 7 9 22 19 Med Med Med Med kW kW m³/h kPa Min Water post-heating accessory SRW Rows 2 2 2 2 2 2 2 2 Max kW 6,79 11,4 11,9 15,3 18,2 23,8 25,5 30,0 Water ow rate (1) Max m³/h 0,58 0,98 1,02 1,32 1,57 2,05 2,19 2,58 Water pressure drop (1) Max kPa 14 24 26 27 32 27 31 52 1 1 1 1 1 1 1 1 kW 3,00 4,50 4,50 4,50 6,00 6,00 6,00 6,00 °C 9,3 8,8 8,3 6,3 7,4 5,2 4,6 4,2 Pa 4 3 4 5 5 7 15 13 2 2 2 2 2 2 2 2 kW 6,00 9,00 9,00 9,00 12,0 12,0 12,0 12,0 °C 18,6 17,6 16,5 12,6 14,7 10,4 9,3 8,4 Pa 4 3 4 5 5 7 15 13 Heating capacity (1) Electric post-heating accessory SRE Stages Heating capacity T air side (Max fan speed) SRE Pressure drop (Max fan speed) Stages Heating capacity T air side (Max fan speed) Pressure drop (Max fan speed) Electrical power supply 2SRE V-Ph-Hz 400-3+N-50 Circular duct supply connector PBC Diameter mm Connections 200 200 200 200 200 200 200 200 2 3 3 3 4 4 4 5 (1) Ambient air 20°C 50% RH, water inlet 70°C outlet 60°C (2) Ambient air 27°C 47% RH, water inlet 7°C outlet 12°C 96 Air handling unit www.lmf.it Q Max fan speed air performances 450 18 17 External Static Pressure (Pa) 400 350 58,6 16 58,6 300 15 14 250 56,8 58,1 58,2 56,8 58,1 200 12 13 10 150 56,0 58,7 52,7 52,0 50,8 100 55,7 52,0 59,5 56,3 58,8 56,3 52,9 58,8 54,0 50 53,0 53,0 60,0 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 Air ow (m³/h) Q Medium fan speed air performances 400 18 17 BAW External Static Pressure (Pa) 350 16 300 56,0 56,0 250 15 53,3 200 12 13 10 48,5 150 54,0 55,9 14 54,8 55,3 50,7 51,2 54,0 53,0 50,0 51,2 50,7 100 50,5 50 53,9 49,5 51,0 51,5 51,1 0 0 500 1000 1500 2000 2500 3000 3500 4000 Air ow (m³/h) Q Minimum fan speed air performances 350 18 External Static Pressure (Pa) 300 17 250 53,3 16 53,0 200 50,5 15 14 45,9 10 47,9 150 50,5 50,5 49,4 47,6 49,0 100 43,3 49,0 45,0 47,9 48,1 50 48,8 43,6 48,1 0 0 500 1000 43,4 12 13 1500 44,8 2000 2500 3000 3500 Air ow (m³/h) Air handling unit www.lmf.it 97 Q Dimensions and weight X6 X1 X1 X5 X2 X3 X5 X2 X2 X6 X3 X4 X2 B H X4 A A C P BAW 10 12 13 14 15 16 17 18 mm 640 1000 1000 1100 1340 1340 1340 1640 mm mm mm mm mm mm mm mm mm 295 450 750 295 135 306 199 137 295 450 750 295 139 290 186 95 135 295 450 750 295 139 290 186 95 135 322 500 835 322 159 306 170 159 151 322 535 950 322 279 306 170 279 152 372 535 950 372 237 328 210 237 238 372 535 950 372 237 328 210 237 238 372 535 950 372 387 328 210 387 238 X6 mm 140 136 136 144 143 114 114 114 Weight of horizontal version Weight of vertical version Accessories L1 Accessories L2 Accessories L3 kg kg mm mm mm 23 30 200 50 400 33 45 200 50 400 36 48 200 50 400 40 54 200 50 400 48 63 200 50 400 55 72 200 50 400 60 75 200 50 400 71 86 200 50 400 BAW UAP SRW SRE PAM PBC L1 L1 L1 L1 L1 BAW A B C H P X1 X2 X3 X4 X5 FOS AF PAS CMX CM L3 L3 L3 FM L2 Q Controls Speed control CVU It is composed of a 3 step fan speed control (min/med/max) and a manual off/cooling/heating switch with capacity to connect an antifreeze thermostat (accessory TEG) that can stop the unit in heating mode. Accessories TEG Antifreeze thermostat 98 Air handling unit www.lmf.it Control Panel PCR This digital controller is intended for temperature regulation in environments equipped with heat recovery unit or air conditioning unit. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the control panel internal sensor or with an external one (accessory NTC). The control panel is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) and/or electric heater; moreover it includes a manual or automatic heating/cooling changeover, an economy function to reduce power consumption (it allows to temporary set an energy saving mode through a reduction of the actual set point temperature by a step when in heating mode, or increasing it by the same step when in cooling mode), and clogged lter alarm by setting the time-to-maintenance. This device can drive in a proportional way both valves and fan in order to control room temperature with the highest comfort and energy saving, following a proportional band for fan and proportional and integral for valves: the regulator will drive this valve through power pulses with one second resolution in a way that its stem will reach the position needed for the regulation, thus performing a modulation. The regulator, as soon as power is rst applied, and before it starts the actual regulation, will perform a stem position re-synchronization cycle, which is obtained by closing the valve for a time which is 150% of the value stored as nominal opening time. This cycle will be periodically repeated in order to recover possible positioning errors which might be accumulated during time. SSE 3 way valve with 3 points actuator 230V remotable temperature sensor for PCR antifreeze thermostat (it can be connected by an electro mechanic wiring thus no alarm is displayed on control panel) on/off damper spring actuator (only in combination with TEG accessory, by an electro mechanic wiring) Multifunction electronic control RQU It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, humidi cation, antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories V3 3 way valve with modulating 0-10V actuator 24V CMX 2 damper mixing box section SSE on/off spring actuator for damper PSTD air lter pressure switch VSA solenoid valve for adiabatic humidi cation/ cooling HAS room hygrostat HCS ductable hygrostat TEG PSTD SSE HAS VS HCS T TL V3P4 RTP4(RTP4-L) Air handling unit www.lmf.it 99 BAW Accessories V3/S230 NTC TEG FSM H INSIDE Compact air conditioning unit FSM from 400 to 7.400 m³/h Q General features FSM unit series is designed and built for those applications in which a minimum amount of space is the rst factor when realizing an air-conditioning system. The series offers 7 models and a wide range of Accessories that permit as many air treatments as they are suitable for a lot of home, commercial and industrial environments. The easy installation, large exibility and high quality of the product complete the features of the unit series. The base unit is supplied with G4 lter, water coil(s) and fan. Q Mechanical features The frame is made from steel pro les and the panels are sandwich type, internally insulated with sound-proof material (10 mm thick. for 10 to 40 model, 20 mm thick. for 50 and 60 models). The panels are prepainted steel type and supplied with gripping seals xed to the frame by steel screws. The base ltering section is composed of G4 ef ciency class synthetic cell lter. The water heat exchanger coils are Cu tubes and Al ns type. The galvanized steel condensate drain tray is easily removable from bottom without disassembling the unit. The fans are double inlet forward curved centrifugal type and 3-speed direct driven type. The electronic connection panel is supplied entirely cabled and is tted with a relay board to control fan input power. 100 Air handling unit www.lmf.it Q Accessories 1 step post electric heater section 2 step post electric heater section 3 step post electric heater section External water heating coil section 2 rows 3 way valve with actuator for RQU 4 rows 3 way valve with actuator for RQU 6 rows 3 way valve with actuator for RQU 3 way valve with actuator for PCR 2 damper mixing box section Adjusting damper On/off damper actuator F6 class compact lter F6 class soft bag lter F7 class soft bag lter F8 class soft bag lter Adiabatic humidi cation section Solenoid valve Prearranged steam humidi er section Fixed ns air intake grille Adjustable nned supply diffuser Suction plenum section Supply plenum section Supply plenum with round adapter for circular duct section Sound attenuator section on return Sound attenuator section on supply Flexible joint Inverter driven fan motors Fan speed control for DDE Air lter pressure switch Room hygrostat Ductable hygrostat 3 step fan speed control Control panel Remotable temperature sensor for PCR Antifreeze thermostat Multifunction electronic control BRE 2BRE 3BRE SRW V32 V34 V36 V3/S230 CMS SRR SSE FC6 FT6 FT7 FT8 UPA VSA UV GRA BMA PAR PMA PCF SLR SLM GAT DDE RDE PSTD HAS HCS CVU PCR NTC TEG RQU FSM MEDIUM AND HIGH EFFICIENCY FILTERING CLASS COMPOSITION WITH VERY EASY INSTALLATION OF MODULAR ELE- ELECTRIC BOARD WITH RELAYS MENTS STEEL FRAME AND INSULATED PANEL FANS MOUNTED ON ANTIVIBRATING MOUNTS EXTREMELY VERY EASY CONNECTION BETWEEN THE BASIC UNIT AND OTHER SECTIONS EASY INTERNAL COMPONENTS ACCESS AND MAINTENANCE EXTRACTABLE FILTER AND DISMOUNTING OF COILS AND FANS FROM BELOW Air handling unit www.lmf.it 101 Q Basic con gurations Single water heating/cooling coil 2 pipes systems FSM 2 FSM 4 FSM 6 2 row coil 4 row coil 6 row coil Two water heating & cooling coils 4 pipes systems 4+2 row coils 6+2 row coils FSM FSM 42 FSM 62 Single water heating/cooling coil and droplet eliminator 2 pipes systems FSM 4S FSM 6S 4 row coil and droplet eliminator 6 row coil and droplet eliminator Single water heating/cooling coil and electric heater 2 pipes systems FSM 4E FSM 6E 102 4 row coil and electric heater 6 row coil and electric heater Air handling unit www.lmf.it Q Model FSM Max Air ow Sound pressure level at 1 m 25 30 40 50 60 2800 3600 4200 5100 6500 850 1400 2350 2700 2950 3100 4100 600 900 1900 1800 1900 1800 2700 Max 51,2 55,3 55,3 56,8 58,3 56,8 59,0 49,0 52,2 54,9 54,5 55,2 50,5 52,4 47,0 49,2 51,4 47,2 51,2 42,4 46,6 1,90 1105 3 4 IP 20 B 3,00 1127 3 4 IP 55 F 5,80 1292 3 4 IP 55 F 5,80 1225 3 4 IP 55 F 230-1-50 6,00 1112 3 4 IP 55 F 7,60 1026 3 4 IP 20 B 11,4 1011 3 4 IP 20 B Med dB(A) Min Full load total current Speci c fan power Fan speeds Poles Motor protection rating Motor insulation class Electrical power supply 20 2000 Min Med m³/h 10 1000 Max A W/(m³/s) n° n° V-Ph-Hz 2 rows coil FSM2 External static pressure Heating capacity (1) Water ow rate (1) Water pressure drop (1) Max Max Max Max Pa kW m³/h kPa 159 8,77 0,75 30 216 16,3 1,40 10 176 23,1 1,99 26 220 27,0 2,32 36 186 31,8 2,73 11 189 33,3 2,86 70 218 43,2 3,72 4 Max Max Max Max Max Max Max Max Pa kW m³/h kPa kW kW m³/h kPa 140 13,0 1,12 17 5,72 4,45 0,98 14 190 25,4 2,18 30 11,3 8,80 1,94 24 150 35,2 3,03 27 15,7 12,2 2,70 22 180 42,5 3,66 39 18,5 14,8 3,18 30 150 50,4 4,33 34 21,9 17,4 3,77 26 160 59,4 5,11 35 27,1 20,9 4,66 30 189 73,5 6,32 17 30,7 24,9 5,28 12 Max Max Max Max Max Pa kW kW m³/h kPa 120 7,19 5,25 1,24 13 165 13,5 10,1 2,32 9 14 19,8 14,4 3,41 25 140 23,7 17,7 4,08 36 114 26,0 20,0 4,47 7 136 31,1 24,3 5,35 4 161 40,2 31,0 6,91 7 Max Max Max kW m³/h kPa 2 8,77 0,75 30 2 16,3 1,40 10 2 23,1 1,99 26 2 27,0 2,32 36 2 31,8 2,73 11 2 33,3 2,86 70 2 43,2 3,72 4 1 3,00 8,8 6 2 6,00 17,6 13 3 9,00 26,5 13 1 4,50 6,6 9 2 9,00 13,2 17 3 13,5 19,9 17 1 6,60 6,9 9 2 13,2 13,9 17 3 19,8 20,8 17 1 7,50 6,1 13 2 15,0 12,3 27 3 22,5 18,4 27 400-3+N-50 1 8,10 5,7 12 2 16,2 11,3 24 3 24,3 17,0 24 1 9,00 5,2 12 2 18,0 10,4 24 3 27,0 15,6 24 1 10,5 4,8 15 2 21,0 9,5 29 3 31,5 14,3 29 Pa Pa Pa Pa 23 34 40 51 27 59 70 87 27 57 67 84 37 95 112 141 34 83 98 123 34 110 130 163 39 135 159 200 mm 200 200 250 250 15 315 315 2 4 4 4 4 4 5 4 rows coil FSM4 FSM External static pressure Heating capacity (1) Water ow rate (1) Water pressure drop (1) Total cooling capacity (2) Sensible cooling capacity (2) Water ow rate (2) Water pressure drop (2) 6 rows coil FSM6 External static pressure Total cooling capacity (2) Sensible cooling capacity (2) Water ow rate (2) Water pressure drop (2) Water post-heating accessory SRW Rows Heating capacity (1) Water ow rate (1) Water pressure drop (1) Electric post-heating accessory BRE Stages Heating capacity T air side (Max fan speed) Pressure drop (Max fan speed) Stages Heating capacity T air side (Max fan speed) Pressure drop (Max fan speed) Stages Heating capacity T air side (Max fan speed) Pressure drop (Max fan speed) Electrical power supply BRE 2BRE 3BRE kW °C Pa kW °C Pa kW °C Pa V-Ph-Hz High ef ciency lters FC6 Pressure drop FT6 Pressure drop FT7 Pressure drop FT8 Pressure drop Max Max Max Max Circular duct supply connector PCF Diameter Connections (1) Ambient air 20°C 50% RH, water inlet 70°C outlet 60°C (2) Ambient air 27°C 47% RH, water inlet 7°C outlet 12°C Air handling unit www.lmf.it 103 Q Max fan speed air performances 400 30 20 External Static Pressure (Pa) 350 40 53,6 53,7 300 50 56,0 60 58,8 56,0 56,0 57,6 54,5 250 25 10 57,3 56,0 55,2 52,1 57,9 56,5 56,5 200 59,0 58,0 55,2 56,8 55,3 150 55,3 59,0 58,3 100 52,0 56,6 50 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 Air ow (m³/h) Q Medium fan speed air performances 350 External Static Pressure (Pa) 300 40 52,6 250 54,0 60 55,4 54,8 50 52,2 25 10 54,9 55,3 200 54,9 52,4 50,0 150 50,5 54,5 100 49,0 43,1 50 52,2 55,0 55,6 54,6 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Air ow (m³/h) Q Minimum fan speed air performances 300 250 External Static Pressure (Pa) FSM 30 20 50 30 49,2 25 200 10 20 49,2 52,0 150 51,4 40 60 47,0 42,4 100 51,2 50 50,6 47,2 43,7 48,3 0 0 500 1000 1500 2000 2500 3000 3500 Air ow (m³/h) 104 Air handling unit www.lmf.it Q Accessory layout GRA PAR CMS SLR FC6 SRR Base unit with single coil UPA SRW FT6-7-8 BRE SLM PCF PMA Base unit with 2 coil (heating and cooling BMA FSM Base unit with coil and droplet eliminator Base unit with cooling coil and electric heater Q Dimensions and weight L W Y1 Y x x2 H ØR A2 A1 Ø1 condensate discharge on side Air ow x x1 x2 Right side connection x x1 x2 Air handling unit www.lmf.it 105 FSM W mm 20 25 30 40 50 60 710 1070 1400 1400 1680 1780 2000 H mm 390 390 390 390 390 480 480 L mm 850 850 850 850 850 960 960 ¾” ¾” ¾” ¾” 1” 1” 1” Ø 2R Ø 4R ¾” ¾” 1” 1” 1” 1¼ 1¼ Ø 6R Ø1 mm ¾” ½” 1” ½” 1” ½” 1” ½” 1¼ ½” 1¼ ½” 1¼ ½” X1 mm 240 306 240 240 306 306 306 Y1 X2 X3 A1 A2 X Y Weight mm mm mm mm mm mm mm kg 216 670 350 235 136 52÷60 270 1030 350 382 82 60÷70 216 318 1360 350 301 136 75÷88 270 318 1360 350 301 82 78÷90 270 418 1640 350 325 82 96÷110 270 435 1720 420 366 160 101÷120 270 285 1940 420 256 160 120÷140 SLR FSM UV UPA SRW BRE SLM PCF-PMA L2 L L2 L2 L1 L1 L2 L1 20 25 CMS FSM 10 L1 PAR FT6-7-8 L1 L1 FSM 10 30 40 50 60 L1 mm 390 390 390 390 390 480 480 L2 mm 850 850 850 850 850 960 960 Q Controls Speed control CVU It is composed of a 3 step fan speed control (min/med/max) and a manual off/cooling/heating switch with capacity to connect an antifreeze thermostat (accessory TEG) that can stop the unit in heating mode. Accessories TEG Antifreeze thermostat Control Panel PCR This digital controller is intended for temperature regulation in environments equipped with heat recovery unit or air conditioning unit. The device automatically controls the fan speed (manual or automatic 2/3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the control panel internal sensor or with an external one (accessory NTC). The control panel is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) and/or electric heater; moreover it includes a manual or automatic heating/cooling changeover, an economy function to reduce power consumption (it allows to temporary set an energy saving mode through a reduction of the actual set point temperature by a step when in heating mode, or increasing it by the same step when in cooling mode), and clogged lter alarm by setting the time-to-maintenance. 106 Air handling unit www.lmf.it This device can drive in a proportional way both valves and fan in order to control room temperature with the highest comfort and energy saving, following a proportional band for fan and proportional and integral for valves: the regulator will drive this valve through power pulses with one second resolution in a way that its stem will reach the position needed for the regulation, thus performing a modulation. The regulator, as soon as power is rst applied, and before it starts the actual regulation, will perform a stem position re-synchronization cycle, which is obtained by closing the valve for a time which is 150% of the value stored as nominal opening time. This cycle will be periodically repeated in order to recover possible positioning errors which might be accumulated during time. Accessories V3/S230 NTC TEG SSE 3 way valve with 3 points actuator 230V remotable temperature sensor for PCR antifreeze thermostat (it can be connected by an electro mechanic wiring thus no alarm is displayed on control panel) on/off damper spring actuator (only in combination with TEG accessory, by an electro mechanic wiring) Multifunction electronic control RQU FSM It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 3 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, humidi cation, antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories V3x 3 way valve with modulating 0-10V actuator 24V CMS 2 damper mixing box SSE on/off spring actuator for damper PSTD air lter pressure switch DDE inverter driven fan motors (only with RDE) VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat Air handling unit www.lmf.it 107 FSM T H INSIDE High pressure compact air conditioning unit FSM T da 500 a 4.200 m³/h Q General features FSM T unit series is designed and built for those applications in which a minimum amount of space and a very high static pressure available are the main factors when realizing an air-conditioning system. The series offers 3 models and a wide range of accessories that permit as many air treatments as they are suitable for a lot of home, commercial and industrial environments. The easy installation, large exibility and high quality of the product complete the features of the unit series. This units are good for ceiling and on view installation. The more than adequate rear door, supplied with 1/4 turn security lock, guarantee simply accessibility to each internal component for maintenance and replacement. The base unit is supplied with G4 lter, water coil and fan. Q Mechanical features The frame is made from steel pro les and the panels are sandwich type, internally insulated with sound-proof material 10 mm thickness. The panels are prepainted steel type and supplied with gripping seals xed to the frame by steel screws. The base ltering section is composed of G4 ef ciency class synthetic cell lter. The water heat exchanger coils are Cu tubes and Al ns type. The galvanized steel condensate drain tray is easily removable from bottom without disassembling the unit. The fans are double inlet forward curved centrifugal type and the electric motors 3-phase with two speeds. 108 Air handling unit www.lmf.it Q Accessories 1 step post electric heater section 2 step post electric heater section 3 step post electric heater section External water heating coil section 2 rows 3 way valve with actuator for RQU 4 rows 3 way valve with actuator for RQU 6 rows 3 way valve with actuator for RQU 3 way valve with actuator for PCR 2 damper mixing box section Adjusting damper On/off damper actuator F6 class compact lter F6 class soft bag lter F7 class soft bag lter F8 class soft bag lter Adiabatic humidi cation section Solenoid valve BRE 2BRE 3BRE SRW V32 V34 V36 V3/S230 CMS SRR SSE FC6 FT6 FT7 FT8 UPA VSA Prearranged steam humidi er section Fixed ns air intake grille Adjustable nned supply diffuser Suction plenum section Supply plenum section Supply plenum with round adapter for circular duct section Sound attenuator section on return Sound attenuator section on supply Flexible joint Air lter pressure switch Room hygrostat Ductable hygrostat Remotable temperature sensor for PCR 3 step fan speed control Control panel Multifunction electronic control for 2 speed motors AND COOLING SLR SLM GAT PSTD HAS HCS NTC CVU-T PCR-T RQ2 FSM T STEEL HEATING UV GRA BMA PAR PMA PCF FRAME AND INSULATED PANEL COIL CONNECTIONS ACCESS TO THE FILTERING SECTION FOR MAINTENANCE EASY ACCESS FROM THE BOTTOM OF THE UNIT TO THE INTERNAL COMPONENTS CONDENSATE DISCHARGE DAMPER Air handling unit www.lmf.it 109 Q Basic con gurations Single water heating/cooling coil 2 pipes systems FSM T 2 2 row coil FSM 4 T 4 row coil FSM 6 T 6 row coil Two water heating & cooling coils 4 pipes systems 4+2 row coils FSM T 62 6+2 row coils FSM T FSM T 42 Single water heating/cooling coil and droplet eliminator 2 pipes systems FSM T 4S 4 row coil and droplet eliminator FSM T 6S 6 row coil and droplet eliminator Single water heating/cooling coil and electric heater 2 pipes systemsi FSM T 4E 4 row coil and electric heater FSM T 6E 6 row coil and electric heater 110 Air handling unit www.lmf.it Q Model FSM T 10 20 30 1300 2400 3600 Air ow m³/h Sound pressure level at 1 m dB(A) 70,1 73,7 73,2 A 1,60 2,70 3,50 Full load total current Full load total power kW 0,55 1,10 1,50 W/(m³/s) 1523 1650 1500 Fan speeds n° 1 1 1 Poles n° 4 4 4 IP 55 IP 55 IP 55 F F Speci c fan power Max Motor protection rating Motor insulation class F Electrical power supply V-Ph-Hz 400-3-50 2 rows coil FSM2 T External static pressure Pa 430 434 440 Heating capacity (1) kW 10,4 18,3 27,0 Water ow rate (1) m³/h 0,89 1,57 2,32 Water pressure drop (1) kPa 43 13 36 4 rows coil FSM4 T Pa 400 400 400 kW 15,9 29,0 42,5 Water ow rate (1) m³/h 1,37 2,49 3,66 Water pressure drop (1) kPa 25 39 39 Total cooling capacity (2) kW 6,95 12,8 18,5 Sensible cooling capacity (2) kW 5,33 9,90 14,8 Water ow rate (2) m³/h 1,20 2,20 3,18 Water pressure drop (2) kPa 20 31 30 FSM T External static pressure Heating capacity (1) 6 rows coil FSM6 T External static pressure Pa 369 365 361 Total cooling capacity (2) kW 8,80 15,7 23,7 Sensible cooling capacity (2) kW 6,42 11,6 17,7 Water ow rate (2) m³/h 1,51 2,70 4,08 Water pressure drop (2) kPa 20 12 36 2 2 2 Heating capacity (1) kW 8,69 15,6 22,7 Water ow rate (1) m³/h 0,75 1,34 1,95 Water pressure drop (1) kPa 30 33 26 1 1 1 kW 3,00 4,50 7,50 °C 6,8 5,5 6,1 Pa 10 12 13 2 2 2 kW 6,00 9,00 15,0 °C 13,6 11,0 12,3 Pa 21 23 26 3 3 3 kW 9,00 13,5 22,5 °C 20,4 16,5 18,4 Pa 21 23 26 Water post-heating accessory SRW Rows Electric post-heating accessory BRE Stages Heating capacity BRE T air side Pressure drop Stages Heating capacity 2BRE T air side Pressure drop Stages Heating capacity 3BRE T air side Pressure drop Electrical power supply V-Ph-Hz 400-3+N-50 High ef ciency lters FC6 Pressure drop Pa 31 33 FT6 Pressure drop Pa 46 72 36 94 FT7 Pressure drop Pa 54 85 111 FT8 Pressure drop Pa 68 106 140 mm 200 200 250 2 4 4 Circular duct supply connector PCF Diameter Connections (1) Ambient air 20°C 50% RH, water inlet 70°C outlet 60°C (2) Ambient air 27°C 47% RH, water inlet 7°C outlet 12°C Air handling unit www.lmf.it 111 Q Max fan speed air performances 650 71,0 External Static Pressure (Pa) 600 20 72,0 550 71,0 30 500 10 73,0 70,0 72,0 450 71,0 400 75,0 72,0 74,0 350 76,0 73,0 76,0 300 0 500 1000 1500 2000 2500 3000 3500 4000 4500 3500 4000 4500 Q Minimum fan speed air performances 350 300 External Static Pressure (Pa) FSM T Air ow (m³/h) 20 30 63,0 250 64,0 200 10 65,0 61,0 63,0 150 62,0 100 64,0 50 66,0 0 0 500 1000 1500 2000 2500 3000 Air ow (m³/h) 112 Air handling unit www.lmf.it Q Dimensions and weight L W Y1 A2 H Y x A1 x2 ØR Ø1 condensate discharge on side Air ow x x1 x2 Right side connection W H L Ø 2R Ø 4R Ø 6R Ø1 X1 Y1 X2 A1 A2 X Y Weight mm mm mm mm mm mm mm mm mm mm mm kg CMS PAR FT6-7-8 L1 L1 L1 FSM T L1 L2 mm mm 10 20 30 710 390 850 ¾” ¾” ¾” ½” 240 215 675 355 360 140 55÷63 1070 390 850 ¾” ¾” 1” ½” 306 215 1035 355 520 140 64÷74 1400 390 850 ¾” 1” 1” ½” 240 215 175 1365 355 518 140 83÷95 SLR FSM T L2 L FSM T FSM T UV UPA SRW BRE SLM PCF-PMA L2 L2 L1 L1 L2 L1 10 20 30 390 850 390 850 390 850 Air handling unit www.lmf.it 113 Q Accessory layout GRA PAR CMS SLR FC6 SRR Base unit with single coil UPA FT6-7-8 SRW BRE SLM PCF PMA Base unit with 2 coil (heating and cooling) BMA FSM T Base unit with coil and droplet eliminator Base unit with cooling coil and electric heater Q Controls Speed control CVU-T It is composed of a 2 step fan speed control (min/max) and a manual off/cooling/heating switch with capacity to connect an antifreeze thermostat (accessory TEG) that can stop the unit in heating mode. Accessories TEG Antifreeze thermostat Control Panel PCR-T This digital controller is intended for temperature regulation in environments equipped with heat recovery unit or air conditioning unit. The device automatically controls the fan speed (manual or automatic 2 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the control panel internal sensor or with an external one (accessory NTC). The control panel is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) and/or electric heater; moreover it includes a manual or automatic heating/cooling changeover, an economy function to reduce power consumption (it allows to temporary set an energy saving mode through a reduction of the actual set point temperature by a step when in heating mode, or increasing it by the same step when in cooling mode), and clogged lter alarm by setting the time-to-maintenance. 114 Air handling unit www.lmf.it This device can drive in a proportional way both valves and fan in order to control room temperature with the highest comfort and energy saving, following a proportional band for fan and proportional and integral for valves: the regulator will drive this valve through power pulses with one second resolution in a way that its stem will reach the position needed for the regulation, thus performing a modulation. The regulator, as soon as power is rst applied, and before it starts the actual regulation, will perform a stem position re-synchronization cycle, which is obtained by closing the valve for a time which is 150% of the value stored as nominal opening time. This cycle will be periodically repeated in order to recover possible positioning errors which might be accumulated during time. Accessories V3/S230 NTC TEG SSE 3 way valve with 3 points actuator 230V remotable temperature sensor for PCR antifreeze thermostat (it can be connected by an electro mechanic wiring thus no alarm is displayed on control panel) on/off damper spring actuator (only in combination with TEG accessory, by an electro mechanic wiring) Multifunction electronic control RQ2 FSM T It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 2 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, humidi cation, antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. Accessories V3x 3 way valve with modulating 0-10V actuator 24V CMS 2 damper mixing box SSE on/off spring actuator for damper PSTD air lter pressure switch VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat Air handling unit www.lmf.it 115 UTW H V INSIDE PARTIAL OUTSIDE Air conditioning unit UTW from 2.000 to 19.000 m³/h Q General features UTW series units are designed and developed to meet a wide range of requests within home, commercial and industrial plants. Proposed in 8 models with an extensive range of accessories, they allow a complete series of air treatments which permit an adaptation for a large variety of applications. The easy installation, large exibility and high quality of the product complete the features of the unit series. Base unit is supplied with G4 lter, water coil and single or twin belt driven fan. They are available in the following base versions: BUH horizontal ow with single water coil; BFV vertical ow with single water coil; BDH horizontal ow with two water coils; E horizontal ow with water coil and electric heater; S horizontal ow with water coil and droplet eliminator. Q Mechanical features The frame is made from steel pro les and the panels are sandwich type, internally insulated with sound and thermalproof material (20 mm thick. for 022 to 110 model, 25 mm thick. for 145 and 198 models). The panels are prepainted steel type and supplied with gripping seals xed to the frame by steel screws, while the inspection panels are supplied with 1/4 turn safety closure. The units stand on solid galvanized steel feet support, designed for allowing the possibility to securely transport or transfer the unit around the location. The fan are double inlet forward curved centrifugal type and electric motors are 3-phase single or twin polarity type; the fan-motor group is put on a robust galvanized steel support with rubber antivibrators. The base ltering section is composed of G4 ef ciency class synthetic cell lter; as an option, F7 ef ciency class rigid bag lter section. The water heat exchange coils are copper tubes and aluminum ns type; the electric heaters are composed of armoured elements mounted in a metallic frame, complete with connection board and safety thermostat. 116 Air handling unit www.lmf.it Q Accessories 1 step post electric heater section 2 step post electric heater section 3 step post electric heater section 2 rows water coil section 2 rows 3 way valve with actuator 4 rows water coil section 4 rows 3 way valve with actuator 6 rows 3 way valve with actuator Heat recovery section 2 damper mixing box section 3 damper mixing box section Adjusting damper On/off damper actuator G4 class plain lter on return F7 class rigid bag lter section F8 class rigid bag lter section SBCE SBC2E SBC3E SBC2 V32 SBC4 V34 V36 REC CM G3S ST SSE PF TS TS8 F9 class rigid bag lter section Prearranged steam humidi er section Adiabatic humidi cation section Solenoid valve Sound attenuator section on supply Sound attenuator section on return Fixed ns air intake grille Supply plenum section Adjustable nned supply diffuser Roof cover Flexible joint Air lter pressure switch Room hygrostat Ductable hygrostat Multifunction electronic control Multifunction electronic control for 2 speed motors TS9 UV UP VSA SSM SSR GAS PMA BRM CPP GAT PSTD HAS HCS RQU RQ2 UTW ELECTRIC MOTOR ON BELT ADJUSTER STEEL EXTREMELY EASY INTERNAL COMPONENTS ACCESS AND MAINTENANCE FRAME AND INSULATED SANDWICH PANELS FAN SECTION MOUNTED ON RUBBER ANTIVIBRATING FILTER EXTRACTION ON SIDE VERTICAL VERSION Air handling unit www.lmf.it 117 Q Model UTW Air ow External static pressure 022 033 055 066 088 110 145 198 m³/h 2000 3100 4400 5700 8000 11000 14000 19000 250 Pa 150 150 200 200 200 250 250 Sound pressure level at 1 m dB(A) 70 73 76 75 73 76 72 74 Full load total power input kW 0,74 1,10 2,20 2,20 3,00 4,40 6,00 4,00 Full load total current A Motor protection rating Motor insulation class Electrical power supply 2,26 3,06 5,20 5,20 6,80 9,68 12,6 7,22 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 F F F F F F F B V-Ph-Hz 400-3+N-50 2 rows coil UTW2 Heating capacity (1) kW 12,6 18,9 26,1 33,3 49,5 67,2 87,3 118 Water ow rate (1) m³/h 1,08 1,63 2,24 2,86 4,26 5,78 7,51 10,1 Water pressure drop (1) kPa 22 51 10 12 11 10 12 30 Heating capacity (1) kW 20,3 30,7 43,8 55,4 80,5 106 138 186 Water ow rate (1) m³/h 1,75 2,64 3,77 4,76 6,92 9,12 11,9 16,0 Water pressure drop (1) kPa 26 62 34 14 16 3 7 11 Total cooling capacity (2) kW 7,76 12,7 18,5 22,3 33,5 38,6 54,9 76,0 UTW 4 rows coil UTW4 Sensible cooling capacity (2) kW 6,30 9,40 13,5 17,0 24,8 32,7 42,7 57,0 Water ow rate (2) m³/h 1,33 2,18 3,18 3,84 5,76 6,64 9,44 13,1 Water pressure drop (2) kPa 16 44 25 10 12 2 4 7 Total cooling capacity (2) kW 9,90 16,4 20,7 26,5 41,3 56,3 67,7 95,6 Sensible cooling capacity (2) kW 8,12 12,2 17,1 21,8 31,7 43,1 55,0 73,9 Water ow rate (2) m³/h 1,70 2,82 3,56 4,56 7,10 9,68 11,6 16,4 Water pressure drop (2) kPa 6 18 3 3 6 6 3 5 2 2 2 2 2 2 2 2 Heating capacity (1) kW 12,6 18,9 26,1 33,3 49,5 67,2 87,3 118 Water ow rate (1) m³/h 1,08 1,63 2,24 2,86 4,26 5,78 7,51 10,1 Water pressure drop (1) kPa 22 51 10 12 11 10 12 30 4 4 4 4 4 4 4 4 Heating capacity (1) kW 20,3 30,7 43,8 55,4 80,5 106 138 186 Water ow rate (1) m³/h 1,75 2,64 3,77 4,76 6,92 9,12 11,9 16,0 Water pressure drop (1) kPa 26 62 34 14 16 3 7 11 1 1 1 1 1 1 1 1 kW 3,00 4,20 4,80 4,80 7,20 7,20 8,40 10,0 °C 4,4 4,0 3,2 2,5 2,6 1,9 1,8 1,5 2 2 2 2 2 2 2 2 kW 6,00 8,40 9,60 9,60 14,4 14,4 16,8 20,0 °C 8,8 8,0 6,4 5,0 5,3 3,9 3,5 3,1 3 3 3 3 3 3 3 3 kW 9,00 12,6 14,4 14,4 21,6 21,6 25,2 30,0 °C 13,2 12,0 9,6 7,4 7,9 5,8 5,3 4,6 6 rows coil UTW6 Water post-heating accessory SBC2 Rows Water post-heating accessory SBC4 Rows Electric post-heating accessory section Stages Heating capacity SBCE T air side Stages Heating capacity SBC2E T air side Stages Heating capacity T air side Electrical power supply SBC3E V-Ph-Hz 400-3+N-50 Recovery accessory REC Ef ciency (3) % 56,7 54,4 50,8 50,7 59,0 57,2 56,5 64,8 Recovered heating capacity (3) kW 9,40 14,0 18,6 24,0 39,2 47,5 58,8 80,8 Supply temperature (3) °C 7,9 7,3 6,5 6,5 8,4 8,0 7,8 9,7 (1) Ambient air 20°C 50% RH, water inlet 70°C outlet 60°C (2) Ambient air 27°C 47% RH, water inlet 7°C outlet 12°C (3) Outdoor air -5°C 80% RH, ambient air 20°C 50% RH 118 Air handling unit www.lmf.it Q Typical layout BUH 2 BUH 4 BUH 6 BDH 42 BDH 62 BDH 64 SV SV Horizontal ow, with one heating water coil and one cooling water coil Horizontal ow, with single water coil UTW BDH 4S BDH 6S BDH 4E BDH 6E SV Horizontal ow, with one water coil and electric heater SV Horizontal ow, with one water coil and droplet eliminator SV BFV 2 BFV 4 BFV 6 Vertical ow, with single water coil Air handling unit www.lmf.it 119 Q Accessory layout PMA SS Base unit TS GAS ST SBC UTW G3S GAS ST Ba se CM un it CM TS UP UV SBC SS PMA 120 Air handling unit www.lmf.it Q Dimensions and weight X1 MO° A Y1 Y1 Ø 20 90 W A M90° X1 X1 Y1 Y1 X2 A A2 ØR A X1 A MO° A1 M90° ØR A2 X2 X1 X1 A 90 Ø 20 W A1 022 033 055 066 088 110 145 198 W A Ø 2R Ø 4R Ø 6R mm mm 850 570 1” 1” 1” 1030 570 1” 1” 1 1/4 1240 630 1” 1” 1 1/4 1240 750 1” 1” 1 1/4 1530 870 1” 1 _” 2” 1530 1110 1 1/4 2” 2” 1850 1180 1 1/4 2” 2 1/2 2100 1320 2” 2” 2 12” X1 mm 240 300 340 400 480 560 480 560 Y1 X2 A1 A2 L1 L2 L3 L4 H P Q R mm mm mm mm 270 790 510 570 570 1140 1080 1140 410 600 210 270 970 510 570 570 1140 1080 1140 410 800 210 290 1180 570 570 630 1260 1080 1260 410 900 210 350 1180 690 570 750 1390 1080 1390 410 1000 310 410 1470 810 570 870 1540 1080 1540 410 1200 310 480 1470 1050 570 1110 1780 1620 1780 410 1300 410 410 390 1770 1100 570 1180 1890 1620 1890 410 1700 510 480 460 2020 1240 570 1320 2030 1620 2030 510 1900 510 780 960 1170 1170 1460 1460 1600 1900 S RxS UTW UTW RxS REC PxQ RxS RxS CM G3S UTW (SV) UP UV L2 L2 SBC2-4 SBCE SSM-SSR PMA L4 L1 90 PxQ H TS L1 L2 L3 L1 A A L1 L1 UTW Air handling unit www.lmf.it 121 Q Typical composition UTW - BDH CM UP Horizontal ow, with 2 damper mixing box, lter, two water coils and evaporative pack humidi er UTW - BDH SV G3S TS SSM UTW Horizontal ow, with return fan, 3 damper mixing box, bag lter, two water coils and supply sound attenuator UTW/V - BFV CM TS SSM UTW/V - BFV GAS PMA BRM Vertical ow, with 2 damper mixing box, bag lter and supply sound attenuator Vertical ow, with return grille, supply plenum with diffuser UTWREC+3ST UTWREC+2ST - 4S TS Horizzontal ow with return fan, heat recovery, 3 damper mixing box and supply fan Horizzontal ow with return fan, heat recovery, fresh air damper, exhaust air damper, bag lter, coil with droplet eliminator and supply fan 122 Air handling unit www.lmf.it Q Controls Multifunction electronic control RQU-RQ2 It consists of an on board electrical panel totally wired and a remote control panel that allows temperature regulation in environments equipped with heat recovery unit or air conditioning unit; it is an easy plug and play electronic control. The device automatically controls the fan speed (manual or automatic 1/2 step fan speed control) as well as the possible valves/electric heater in order to adjust the room temperature in the most suitable way. Temperature acquisition can be performed either with the supply air sensor, as standard, or with the return air sensor. The electronic control is suitable to manage two water coil for heating/cooling (4 pipes system), or single coil (2 pipes system) with or without electric pre and/or post heater and free-cooling/free-heating by-pass damper based on fresh air sensor; moreover it includes a manual or automatic heating/cooling changeover, manage of mixing box for quick winter startup, winter humidi cation, heat exchanger defrost based on exhaust air sensor (it activates electric pre heater and mixing box), antifreeze alarm (it stops the unit and full open water heating coil), clogged lter alarm by pressure switch, electric heater post ventilation and thermal protection alarm, remote ON-OFF via digital input, sensors diagnostic, integrated scheduling clock with four programs for each day of the week and RS485 serial interface with MODBUS protocol. UTW Accessories V3x 3 way valve with modulating 0-10V actuator 24V G3S 3 damper mixing box SSE on/off spring actuator for damper PSTD air lter pressure switch VSA solenoid valve for adiabatic humidi cation/cooling HAS room hygrostat HCS ductable hygrostat Air handling unit www.lmf.it 123 FLEX Efficiency Efficiency Efficiency >50% >70% >80% H V INSIDE PARTIAL OUTSIDE FULL OUTSIDE Air handling unit FLEX from 1.000 to 100.000 m³/h Q General features The FLEX series is the new range of Air Handling Units. Designed for maximum exibility in the selection, design and installation process, these units are produced with latest generation equipments, able to keep a very high quality standard. FLEX series is available in 25 sizes and it can cover a request for air ow rates from 1.000 to 100.000 m3/h. This series is the best solution for all plants that need heat, venting and air conditioning or generally air handling, from domestic to industrial installations. For this reason, the range includes the widest range of sections, components and accessories currently available on the market: fans, coils, heat recovery systems, lters, humidi cation, control systems and accessories, designed to meet the best comfort, in complete compliance with technical standards in the HVAC market. Particularly, the thermo-mechanical performance of the casing are declared according to UNI EN 1886, which classi es the mechanical strength, the air leakage, the heating transfer coef cient and the thermal bridging class. It has also been paid big attention to safety requirements, in fact all machines are equipped as standard with protection devices accordingly to the Machinery Directive 2006/42/EC and appropriate instructions for proper installation, use and maintenance. A friendly use selection software is available for the complete range and accessories. The constant automatic updating makes the software a dynamic instrument and subject to constant improvements. 124 Air handling unit www.lmf.it Q Mechanical features LThe frame is made from extruded ALUMINUM pro les with a safety shape that eliminates dangerous internal protuberances, due the screws used to joint the panels; so nally no screws are visible inside the unit. An EPDM gasket is installed on the pro le; it is formed with a rigid base for the frame xing and a soft surface to adapt to the panel and to guarantee the minimum leakage of the casing. A the destination of the unit: == size from 14 to 215 == size from 235 to 855 == size from 14 to 215 == size from 235 to 855 B C FLEX In this range, 4 different frames are used, according to size and A) 40 mm standard pro le, with 42 mm thickness panel B) 60 mm standard pro le, with 62 mm thickness panel C) 40 mm thermal break pro le, with 42 mm thickness panel D) 60 mm thermal break pro le, with 62 mm thickness panel D The execution with thermal break pro le is particularly suitable in the cases in which a strong difference of temperature is present between inside and outside unit: very warm or very cold areas and/or installations with very strong cooling or heating treatment. Very suitable for tropical environments. The panels are available in the following con gurations: External side in prepainted steel RAL 9002 internal side in galvanized steel External side in prepainted steel RAL 9002 internal side in ALUMINUM External side in prepainted steel RAL 9002 internal side in stainless steel Different combinations of panels/materials can be made on request. Air handling unit www.lmf.it 125 Q Air ow rates Air ow rate related to air velocity through the coil FLEX Size 2,00 2,5 3,0 3,5 4,2 m³/h m3/s m³/h m3/s m³/h m3/s m³/h m3/s m³/h m3/s 14 27 1037 1953 0,288 0,542 1296 2441 0,360 0,678 1555 2929 0,432 0,814 1814 3417 0,504 0,949 2177 4101 0,605 1,139 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 3469 4253 5037 6411 7409 8407 10055 11409 12763 14118 15472 16900 18559 20218 24430 28439 32448 38042 42742 47442 52142 56843 61543 0,964 1,181 1,399 1,781 2,058 2,335 2,793 3,169 3,545 3,922 4,298 4,694 5,155 5,616 6,786 7,900 9,013 10,567 11,873 13,178 14,484 15,790 17,095 4336 5316 6296 8014 9261 10508 12569 14261 15954 17647 19340 21125 23198 25272 30537 35548 40559 47552 53428 59303 65178 71053 76928 1,205 1,477 1,749 2,226 2,573 2,919 3,491 3,962 4,432 4,902 5,372 5,868 6,444 7,020 8,483 9,875 11,267 13,209 14,841 16,473 18,105 19,737 21,369 5203 6380 7556 9616 11113 12610 15082 17114 19145 21177 23208 25350 27838 30326 36644 42658 48671 57063 64113 71163 78214 85264 92314 1,445 1,772 2,099 2,671 3,087 3,503 4,190 4,754 5,318 5,882 6,447 7,042 7,733 8,424 10,179 11,849 13,520 15,851 17,809 19,768 21,726 23,684 25,643 6071 7443 8815 11219 12965 14712 17596 19966 22336 24706 27076 29575 32478 35381 42752 49767 56783 66573 74799 83024 91249 99474 107700 1,686 2,067 2,449 3,116 3,602 4,087 4,888 5,546 6,204 6,863 7,521 8,215 9,022 9,828 11,876 13,824 15,773 18,493 20,777 23,062 25,347 27,632 29,917 7285 8931 10578 13463 15558 17654 21115 23959 26803 29647 32491 35490 38973 42457 51302 59721 68140 79888 89758 99629 109499 119369 129240 2,024 2,481 2,938 3,740 4,322 4,904 5,865 6,655 7,445 8,235 9,025 9,858 10,826 11,794 14,251 16,589 18,928 22,191 24,933 27,675 30,416 33,158 35,900 Q Dimensions and weight diagram 1000 2000 5000 20000 10000 50000 100000 2 2,5 3 3,5 4 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 126 724 789 855 Air handling unit www.lmf.it Q The main dimensions Size Panel thickness Width Height* Module Coil mm mm mm xwidth xheight W mm H mm Surface m² 42 700 655 660 1,00 0,75 400 360 0,14 27 42 865 820 660 1,25 1,00 565 480 0,27 48 42 1030 985 660 1,50 1,25 730 660 0,48 59 42 1195 985 660 1,75 1,25 895 660 0,59 70 42 1360 985 660 2,00 1,25 1060 660 0,70 89 42 1360 1150 660 2,00 1,50 1060 840 0,89 103 42 1525 1150 660 2,25 1,50 1225 840 1,03 117 42 1690 1150 660 2,50 1,50 1390 840 1,17 140 42 1525 1480 660 2,25 2,00 1225 1140 1,40 158 42 1690 1480 660 2,50 2,00 1390 1140 1,58 177 42 1855 1480 660 2,75 2,00 1555 1140 1,77 196 42 2020 1480 660 3,00 2,00 1720 1140 1,96 215 42 2185 1480 660 3,25 2,00 1885 1140 2,15 235 60 1980 1780 640 3,00 2,50 1630 1440 2,35 258 60 2140 1780 640 3,25 2,50 1790 1440 2,58 281 60 2300 1780 640 3,50 2,50 1950 1440 2,81 339 60 2300 2100 640 3,50 3,00 1950 1740 3,39 395 60 2620 2100 640 4,00 3,00 2270 1740 3,95 451 60 2940 2100 640 4,50 3,00 2590 1740 4,51 528 60 2940 2420 640 4,50 3,50 2590 2040 5,28 594 60 3260 2420 640 5,00 3,50 2910 2040 5,94 659 60 3580 2420 640 5,50 3,50 3230 2040 6,59 724 60 3900 2420 640 6,00 3,50 3550 2040 7,24 789 60 4220 2420 640 6,50 3,50 3870 2040 7,89 855 60 4540 2420 640 7,00 3,50 4190 2040 8,55 FLEX mm 14 * height including basement (120 mm) Q Casing features Characteristics From size 14 to 215 From size 235 to 855 Standard pro le Thermal break pro le Standard pro le Thermal break pro le Casing strength D1 D1 D1 D1 Casing air leakage (-400 Pa/ +700 Pa) L1 L1 L1 L1 Filter by pass leakage F9 F9 F9 F9 Thermal transmittance T2 T2 T2 T2 Thermal bridging factor TB3 TB2 TB1 TB1 Minimum noise reduction (dB) 34 34 36 36 Air handling unit www.lmf.it 127 EXTREMELY EASY INTERNAL COMPONENTS ACCESS FOR INSPECTIONS AND MAINTENANCE FLEX WIDE RANGE OF FILTRATION SYSTEM DAMPER FULLY ALUMINUM MADE, WITH BLADES IN SPECIAL PROFILE TO MINIMIZE PRESSURE DROP, AND NYLON GEAR AND GASKET All the heating and cooling sections are provided with removable coils. The available heating coils are the following: by hot or overheat water by steam condensing electric with armoured elements The available cooling coils are the following: by chilled water directly expansion The cooling sections are provided by a removable drain panel. 128 Air handling unit www.lmf.it The humidi cation systems are available in all the different version presents on the market: by steam by evaporative pack with or without ricirculation pump by air washer by high pressured water by ultrasounds by compressed air and water atomizers Particular importance on energy saving is used in order to guarantee the best ef ciency of the unit. The FLEX range offers the possibility to choose from the main recovery systems: ALUMINUM plate cross ow; Thermal wheel recovery; Run around coils; Heat pipes. FLEX The fan section is the most important component in the sizing of an air handling unit. For each size there is a variable number of potential fans with different features, adaptable to the real working point of the project to optimize ef ciency, noise level and, in general, the working mode of the machine. The type of fans installed are the following: double inlet forward blades double inlet backward blades plug-fan On the fan sections a safety mesh is provided. A copper cable ensures the grounding between the suspended fan base and the main frame. The micro switch installed on the inspection door. Air handling unit www.lmf.it 129 Q Typical layout Con guration 1 Structure with aluminum frame and panels in galvanized steel inside and prepainted steel outside, insulating material. Air intake with damper. Steam humidi er section; droplet eliminator in PVC; ALUMINUM condensate drain tray; Supply fan section with forward curved centrifugal fan, three-phase electric motor and transmission with belt. G4 pre lter and F7 rigid bag lter; Cu-Al 2 row heating coil; FLEX Cu-Al 6 row cooling coil; Model Air ow Static pressure Motor power Heating power (1) Cooling power (2) Steam rate 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 m³/h 1400 2700 4700 5800 6900 8700 10000 11500 13600 15500 17500 20000 22000 24000 26000 29000 34000 40000 45000 53000 60000 67000 74000 81000 88000 Pa 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 300 300 300 300 kW 0.75 1.5 2.2 3.0 3.0 4.0 5.5 2x 3.0 7.5 7.5 7.5 11 11 11 15 15 15 18.5 18.5 30 30 30 30 37 2x 22 kW 14 25 46 54 64 81 97 112 132 143 161 183 203 218 240 267 317 373 419 494 559 632 698 764 830 kW 11 18 37 47 53 68 81 86 109 117 135 155 174 183 204 229 273 278 328 384 447 513 576 641 687 kg/h 5 10 10 20 20 40 40 40 40 40 60 60 60 80 80 80 80 80 120 120 120 120 180 180 180 Dimensions L (mm) 3585 3750 3915 3915 4080 4080 4080 4080 4245 4410 4410 4575 4575 4855 4855 4980 4980 5140 5300 5300 5300 5300 5620 5620 5620 H (mm) 655 820 985 985 985 1150 1150 1150 1480 1480 1480 1480 1480 1780 1780 1780 2100 2100 2100 2420 2420 2420 2420 2420 2420 P (mm) 700 865 1030 1195 1360 1360 1525 1690 1525 1690 1855 2020 2185 1980 2140 2300 2300 2620 2940 2940 3260 3580 3900 4220 4540 Fan sections ef ciency always >60% (1) External air temperature 5°C db (supply >22°C) Heating water temperature inlet 70°C outlet 60°C. (2) External air temperature 32°C db 50% ru (supply <18°C) Cooling water temperature inlet 7°C outlet 12°C Con guration 2 Structure with aluminum frame and panels in galvanized steel inside and prepainted steel outside, insulating material. Mixing box with 2 dampers. G4 pre lter and F7 rigid bag lter; Cu-Al 2 row heating coil; Cu-Al 4 row cooling DX coil; Steam humidi er; droplet eliminator in PVC; ALUMINUM condensate drain tray; Post-heating electric heater; Supply fan section with plug-fan and three-phase electric motor. Model Air ow Static Pressure Motor power Heating power (1) Cooling power (2) Steam rate Heating power (3) 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 m³/h 1400 2700 4700 5800 6900 8700 10000 11500 13600 15500 17500 20000 22000 24000 26000 29000 34000 40000 45000 53000 60000 67000 74000 81000 88000 Pa 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 300 300 300 300 kW 0.55 1.1 2.2 3.0 3.0 4.0 4.0 5.5 5.5 5.5 7.5 7.5 11 11 11 11 15 18.5 18.5 30 37 2x18,5 2x 18,5 2 x 18,5 2 x 18,5 kW 14 25 46 54 64 81 97 112 132 143 161 183 203 218 240 267 317 373 419 494 559 632 698 764 830 kW 8.8 17.4 30.5 37.5 44.7 57.7 66.6 76 89.5 102 114.8 150.4 141 156.2 170.2 187.3 221.2 260.4 294.5 348 368 495 544 590 675 kg/h 5 10 10 20 20 40 40 40 40 40 60 60 60 80 80 80 80 80 120 120 120 120 180 180 180 kW 3 5 9 11 13 16 19 21 25 29 32 36 39 43 47 51 61 72 82 96 107 119 131 143 155 Dimensions L (mm) 4080 4245 4245 4245 4410 4740 4905 4905 4905 5070 5070 5070 5235 5780 5780 5780 6100 6100 6420 6420 6800 6800 6800 6800 6800 H (mm) 655 820 985 985 985 1150 1150 1150 1480 1480 1480 1480 1480 1780 1780 1780 2100 2100 2100 2420 2420 2420 2420 2420 2420 P (mm) 700 865 1030 1195 1360 1360 1525 1690 1525 1690 1855 2020 2185 1980 2140 2300 2300 2620 2940 2940 3260 3580 3900 4220 4540 Fan sections ef ciency always >60% (1) External air temperature -5°C db (supply >23°C) Heating water temperature inlet 70°C outlet 60°C. (2) External air temperature 30°C db 50% ru (supply <18°C) R410A Evap. temperature 7°C (3) Air temperature 18°C db (supply 23°C) - Power supply 400V - 3ph - 50Hz 130 Air handling unit www.lmf.it Con guration 3 Structure with aluminum frame and panels in galvanized steel inside and prepainted steel outside, insulating material. droplet eliminator in PVC; ALUMINUM condensate drain tray; Mixing box with 2 dampers. Supply fan section with plug-fan and three-phase electric motor. G4 pre lter and F7 rigid bag lter; Gas heater. Cu-Al 4 row cooling DX coil; Model Static pressure Motor power Cooling power (1) Heating power (2) m³/h 1400 2700 4700 5800 6900 8700 10000 11500 13600 15500 17500 20000 22000 24000 26000 29000 34000 40000 45000 53000 Pa 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 kW 0,55 1,1 2,2 2,2 2,2 3,0 4,0 5,5 5,5 5,5 7,5 7,5 7,5 11 11 18,5 18,5 18,5 18,5 30 kW 8.8 17.4 30.5 37.5 44.7 57.7 66.6 76 89.5 102 114.8 150.4 141 156.2 170.2 187.3 221.2 260.4 294.5 348 kW 20-34 27-46 41-69 55-93 55-93 76-127 76-127 90-151 111-186 139-232 174-290 174-290 174-290 208-348 208-348 244-407 279-465 313-522 361-603 403-672 Dimensions L (mm) 4080 4080 4410 4410 4575 5070 5275 5275 5605 5770 5895 5895 6100 6320 6320 6480 6540 7020 7340 7500 H (mm) 655 820 985 985 985 1150 1150 1150 1480 1480 1480 1480 1480 1780 1780 1780 2100 2100 2100 2420 P (mm) 700 865 1030 1195 1360 1360 1525 1690 1525 1690 1855 2020 2185 1980 2140 2300 2300 2620 2940 2940 FLEX 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 Air ow NOT AVAILABLE Fan sections ef ciency always >60% (1) External air temperature 30°C db 50% ru (supply <18°C) (2) External air temperature -5°C db (supply 20°C) Con guration 4 Structure with aluminum frame and panels in galvanized steel inside and prepainted steel outside, insulating material. Return fan section with forward curved centrifugal fan, three-phase electric motor and transmission with belt. Mixing box with 3 dampers G4 pre lter and F7 rigid bag lter; Model Air ow Static pressure 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 m³/h 1400 2700 4700 5800 6900 8700 10000 11500 13600 15500 17500 20000 22000 24000 26000 29000 34000 40000 45000 53000 60000 67000 74000 81000 88000 Pa 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 300 300 300 300 R410A Evap. temperature 7°C. Cu-Al 2 row heating coil; Cu-Al 6 row cooling coil; Steam humidi er section; droplet eliminator in PVC; ALUMINUM condensate drain tray; Cu-Al 1 row post-heating coil; Supply fan section with forward curved centrifugal fan, three-phase electric motor and transmission with belt. Motor power Supply return Heating power (1) Cooling power (2) Steam rate Heating power (3) kW 0.75 1,5 2,2 2,2 3,0 4,0 4,0 5,5 7,5 7,5 7,5 7,5 11 11 11 11 15 15 15 18,5 22 30 30 37 2X 18,5 kW 0.25 0.55 1,1 1,1 1,5 1,5 2,2 3,0 3,0 3,0 3,0 4,0 5,5 5,5 5,5 5,5 7,5 11 11 11 15 18,5 18,5 22 2X15 kW 10 18 33 41 48 61 70 77 95 108 122 137 141 166 182 187 219 270 309 363 413 464 513 521 606 kW 8 16 28 35 41 53 58 67 82 93 106 113 126 144 148 166 198 239 236 279 324 370 418 465 512 kg/h 5 10 10 20 20 40 40 40 40 40 60 60 60 80 80 80 80 80 120 120 120 120 180 180 180 kW 3 6 10 13 15 19 22 25 30 35 38 43 48 52 57 63 75 80 96 113 129 146 162 178 189 Dimensions L (mm) 5605 5935 6295 6430 6925 7090 7090 7090 7750 8105 8105 8270 8245 9040 9200 9680 9680 9680 10000 10000 10000 10000 10320 10320 10320 H (mm) 655 820 985 985 985 1150 1150 1150 1480 1480 1480 1480 1480 1780 1780 1780 2100 2100 2100 2420 2420 2420 2420 2420 2420 P (mm) 700 865 1030 1195 1360 1360 1525 1690 1525 1690 1855 2020 2185 1980 2140 2300 2300 2620 2940 2940 3260 3580 3900 4220 4540 Fan sections ef ciency always >60% (1) External air temperature 5°C db (supply >24°C) Heating water temperature inlet 70°C outlet 60°C. (2) External air temperature 30°C db 50% ru (supply <18°C) ) Cooling water temperature inlet 7°C outlet 12°C. (3) Air temperature 18°C db (supply >23°C) Heating water temperature inlet 45°C outlet 40°C. Air handling unit www.lmf.it 131 Con guration 5 FLEX Structure with aluminum frame and panels in galvanized steel inside and prepainted steel outside, insulating material. G4 pre lter on the return side; Return fan section with plug-fan and three-phase electric motor. G4 pre lter on the fresh air side; Cross ow heat recovery with built-in by-pass damper for free-cooling mode, with fresh air damper and Model Air ow Static pressure 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 m³/h 1400 2700 4700 5800 6900 8700 10000 11500 13600 15500 17500 20000 22000 24000 26000 29000 34000 40000 45000 53000 60000 67000 74000 81000 88000 Pa 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 300 300 300 300 exhaust air damper; F7 rigid bag lter; Cu-Al 2 row heating coil; Cu-Al 4 row cooling coil; droplet eliminator in PVC; ALUMINUM condensate drain tray; Supply fan section with plug-fan and three-phase electric motor. Motor power Supply Return Recovery ef ciency (1) Recovery power (1) Heating power (2) Cooling power (3) kW 0,55 1,1 2,2 3,0 3,0 4,0 4,0 5,5 5,5 7,5 7,5 11 11 11 11 11 18,5 18,5 18,5 kW 0,55 1,1 2,2 3,0 4,0 4,0 4,0 5,5 7,5 11 11 11 11 11 11 15 18,5 18,5 18,5 % 53,7 49 53,6 53 53 57 54 53,8 51 51,7 52,8 52,5 50,8 52 52 52 54 54 50,5 kW 7,5 13,1 25,3 31 36,7 50 54 62 70,9 80,5 92,8 105 112 125 136 151 185 217 228 kW 10 19 33 40 48 60 65 79 98 113 119 136 154 165 180 202 232 261 307 kW 11 20 35 43 49 64 76 81 102 119 126 145 161 173 192 216 255 274 329 Dimensions L (mm) 3585 3585 4080 4080 4245 4410 4905 4905 4905 4905 5400 5400 5400 5620 5780 5780 5780 5940 6100 H (mm) 1190 1520 1850 1850 1850 2180 2180 2180 2840 2840 2840 2840 2840 3440 3440 3440 4080 4080 4080 CONTACT TECHNICAL DEPARTMENT P (mm) 700 865 1030 1195 1360 1360 1525 1690 1525 1690 1855 2020 2185 1980 2140 2300 2300 2620 2940 2940 3260 3580 3900 4220 4540 Fan sections ef ciency always >50% (1) External air temperature -10°C db 90% ru - Room air temperature 20°C db 50% ru. (2) Inlet air temperature >24°C db Heating water temperature inlet 45°C outlet 40°C. (3) Inlet air temperature <20°C db Cooling water temperature inlet 7°C outlet 12°C. Con guration 6 Structure with aluminum frame and panels in galvanized steel inside and prepainted steel outside, insulating material. G4 pre lter on the return side; Return fan section with forward curved centrifugal fan, three-phase electric motor and transmission with belt. G4 pre lter on the fresh air side; Cross ow heat recovery with fresh air damper and exhaust air damper; Model Air ow Static pressure 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 m³/h 1400 2700 4700 5800 6900 8700 10000 11500 13600 15500 17500 20000 22000 24000 26000 29000 34000 40000 45000 53000 60000 67000 74000 81000 88000 Pa 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 300 300 300 300 F7 rigid bag lter; Cu-Al 2 row heating coil; Cu-Al 6 row cooling coil; Steam humidi er section droplet eliminator in PVC; ALUMINUM condensate drain tray; Supply fan section with forward curved centrifugal fan, three-phase electric motor and transmission with belt. Adbolute lter section class H 13 with inspection door. Motor power Supply Return Recovery ef ciency (1) Recovery power (1) Heating power (2) Cooling power (3) kW 1,1 1,5 1,5 4,0 4,0 5,5 5,5 2x3 7,5 11 11 11 15 15 15 15 22 22 22 kW 0,55 1,1 3 2,2 3 3 4 2x2,2 5,5 5,5 7,5 7,5 7,5 7,5 11 11 15 15 18,5 % 55,7 53,3 54,9 54,8 54,6 58,5 55 59 53,8 58 55 54 53 57 54 54 53 52 53 kW 7,8 14,4 25,9 32 37,8 51 56 69 73 91 96 109 117 139 142 158 181 212 239 kW 9 19 33 39 47 59 71 79 97 106 117 134 151 156 167 198 224 263 322 kW 10 18 32 41 48 58 70 82 95 110 116 134 150 158 176 198 210 273 284 CONTACT TECHNICAL DEPARTMENT Dimensions L (mm) 6510 6840 7500 7830 7830 8160 8490 8160 8820 8820 9150 9315 9480 10120 10120 10440 10440 11460 11460 H (mm) 1190 1520 1850 1850 1850 2180 2180 2180 2840 2840 2840 2840 2840 3440 3440 3440 4080 4080 4080 P (mm) 700 865 1030 1195 1360 1360 1525 1690 1525 1690 1855 2020 2185 1980 2140 2300 2300 2620 2940 2940 3260 3580 3900 4220 4540 Fan sections ef ciency always >60% (1) External air temperature -10°C db - Room air temperature 20°C db 50% ru. (2) Inlet air temperature >25°C db Heating water temperature inlet 45°C outlet 40°C. (3) Inlet air temperature <20°C db Cooling water temperature inlet 7°C outlet 12°C 132 Air handling unit www.lmf.it Con guration 7 Structure with aluminum frame and panels in galvanized steel inside and prepainted steel outside, insulating material. G4 pre lter on the return side and on the fresh air side; Return fan section with forward curved centrifugal fan, three-phase electric motor and transmission with belt. Thermal wheels heat recovery with fresh air damper and return air damper; Cu-Al 2 row heating coil; Supply fan section with forward curved centrifugal fan, three-phase electric motor and transmission with belt. Motor power Air ow Static pressure Supply Return Recovery ef ciency (1) Recovery power (1) Heating power (2) 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 m³/h 1600 3100 5400 6600 7900 10000 12000 14000 16000 18000 20000 22000 25000 27000 30000 33000 36000 40000 45000 53000 60000 67000 74000 81000 88000 Pa 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 300 300 300 300 kW 0,75 1,5 3,0 3,0 4,0 5,5 5,5 2x4 11 11 11 11 15 15 15 15 18,5 18,5 18,5 30 30 30 37 37 2 x 18,5 kW 0,75 1,5 3,0 3,0 4,0 5,5 5,5 2x4 7,5 11 11 11 15 15 15 15 18,5 18,5 18,5 30 30 30 37 37 2 x 18,5 % 69 67 64 65 68 65 65 63 60 62 63 63 62 62 62 62 62 64 66 64 65 66 68 69 70 kW 15.6 29.4 49.4 61 75.7 91.9 109.7 124.5 135 158 178 197 219 221 256 289 303 360 418 480 549 629 710 793 871 kW 9 18 29 39 46 53 65 77 100 109 115 130 149 158 178 198 224 262 303 346 395 393 396 392 381 Dimensions L (mm) 2470 2635 2800 2965 2965 2965 2965 2965 3295 3295 3295 3460 3460 3920 4080 4240 4240 4240 4400 4720 4720 4880 4880 4880 4880 H (mm) 1190 1520 1850 1850 1850 2180 2180 2180 2840 2840 2840 2840 2840 3440 3440 3440 4080 4080 4080 4720 4720 4720 4720 4720 4720 P (mm) 700 865 1030 1195 1360 1360 1525 1690 1525 1690 1855 2020 2185 1980 2140 2300 2300 2620 2940 2940 3260 3580 3900 4220 4540 FLEX Model Fan sections ef ciency always >60% (1) External air temperature -10°C db - Room air temperature 20°C db 50% ru. (2) Inlet air temperature >25°C db Heating water temperature inlet 45°C outlet 40°C. Con guration 8 Structure with aluminum frame and panels in galvanized steel inside and prepainted steel outside, insulating material. Fresh air damper and return air damper; G4 pre lter on the return side and on the fresh air side; Return fan section with plug-fan and three-phase electric motor. Thermal wheels heat recovery with fresh air damper and return air damper; F7 rigid bag lter; Cu-Al 2 row heating coil; Cu-Al 4 row cooling coil; droplet eliminator in PVC; ALUMINUM condensate drain tray; Supply fan section with plug-fan and three-phase electric motor. Motor power Model Air ow Static pressure Supply Return Recovery ef ciency (1) Recovery power (1) Heating power (2) Cooling power (3) 14 27 48 59 70 89 103 117 140 158 177 196 215 235 258 281 339 395 451 528 594 659 724 789 855 m³/h 1400 2700 4700 5800 6900 8700 10000 11500 13600 15500 17500 20000 22000 24000 26000 29000 34000 40000 45000 53000 60000 67000 74000 81000 88000 Pa 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 300 300 300 300 kW 0,55 1,5 2,2 3,0 3,0 4,0 5,5 5,5 7,5 7,5 11 11 11 15 15 15 18,5 22 30 30 37 2 x 18,5 2 x 18,5 2 x 22 2 x 22 kW 0,55 1,1 2,2 3,0 4,0 4,0 5,5 5,5 5,5 7,5 7,5 11 11 11 11 15 15 18,5 22 30 30 2 x 15 2 x 15 2 x 18,5 2 x 18,5 % 71 69 67 68 70 67 68 67 65 65 66 65 68 63 65 65 63 64 66 64,5 65 63 68 69 70 kW 14 26,5 44 55,5 68,5 83 96 108 124 142 162 184 210 213 237 264 300 360 418 480 584 593 710 793 871 kW 8 14 26 32 37 49 55 64 76 87 99 107 114 138 139 155 186 216 249 299 338 373 384 406 396 kW 11 20 35 43 49 64 76 81 102 119 126 145 161 173 192 216 255 281 307 363 421 581 765 647 703 Dimensions L (mm) 3460 3460 3625 3625 3790 3955 3955 4120 4120 4120 4285 4285 4285 4720 4720 4720 5040 5040 5200 5360 5580 5740 5740 5740 5740 H (mm) 1190 1520 1850 1850 1850 2180 2180 2180 2840 2840 2840 2840 2840 3440 3440 3440 4080 4080 4080 4720 4720 4720 4720 4720 4720 P (mm) 700 865 1030 1195 1360 1360 1525 1690 1525 1690 1855 2020 2185 1980 2140 2300 2300 2620 2940 2940 3260 3580 3900 4220 4540 Fan sections ef ciency always >60% (1) External air temperature -10°C db - Room air temperature 20°C db 50% ru. (2) Inlet air temperature > 25°C db Heating water temperature inlet 45°C outlet 40°C. (3) Inlet air temperature < 20°C db Cooling water temperature inlet 7°C outlet 12°C Air handling unit www.lmf.it 133 CTE INSIDE PARTIAL OUTSIDE Direct driven fan box from 250 to 7.000 m³/h Q General features The CTE units have been designed and manufactured to be installed in small and medium size ventilation plants. This unit has one speed or three speed standard motor and 250 to 7000 m³/h air ow range. Thank to the high external static pressure, it is possible to install long air ducts to extract or supply air from or to the rooms. CTE Q Mechanical features The frame is made from galvanized steel. A side panel can be opened to inspect the unit. The acoustic insulation is obtained by an adequate thickness of polyester. The fans are double inlet forward curved centrifugal type with statically and dynamically balanced wheels reducing vibrations and noise. Anti-vibrators, which attenuate any vibration transmission, have been placed between the frame and the motor-fan assembly. A cable gland is tted to the unit front panel for easy electrical connections. 134 Fan unit www.lmf.it Q Accessories Roof cover TP External hood CU Overpressure damper SG Supports H=90 mm PD Single-phase electronic speed regulator RCS 3 step fan speed control RCV Auto transformer speed regulator VT Q Model CTE 1v Type fan 576 574 696 694 616 614 726 726T 7/7 7/7 9/9 9/9 10/10 10/10 12/12 12/12 Shaft power W 62 147 147 300 254 373 736 1100 Max current A 1,00 1,80 2,10 3,50 2,65 4,80 7,60 7,80/4,50 Fan speeds 1 1 1 1 1 1 1 1 Poles 6 4 6 4 6 4 6 6 20 20 20 20 20 20 20 20 B B B B B B B B Protection degree IP Temperature class V-ph-Hz CTE 3v Type fan 230-1-50 230/400-3-50 576V 574V 696V 694V 616V 614V 726V 7/7 7/7 9/9 9/9 10/10 10/10 12/12 Shaft power W 147 147 245 420 245 420 736 Max current A 1,15 1,90 2,50 3,80 3,00 4,1 6,80 Fan speeds 3 3 3 3 3 3 3 Poles 6 4 6 4 6 4 6 32 20 20 20 20 20 20 B B F B F B F Protection degree IP Temperature class Electrical power supply V-ph-Hz 230-1-50 Fan unit www.lmf.it 135 CTE Electrical power supply Q Dimensions and weight CTE 574 - 576 694 - 696 614 - 616 726 - 726T A mm 500 600 600 700 F mm 218 272 299 351 H mm 242 308 342 406 Weight kg 28-33 35-40 40-45 60-70 F B E A B Q Performances The following tables indicate, model by model and depending on the required air ow rate, the external static pressure [Pa] and the sound pressure level at 1 m far from unit [dB(A)]. CTE 1v m³/h 576 CTE 574 696 694 616 614 726 726T 136 250 500 750 Pa 125 118 116 97 dB(A) Pa dB(A) Pa dB(A) Pa dB(A) Pa dB(A) Pa dB(A) Pa dB(A) Pa dB(A) 44,1 260 52,0 190 46,5 428 54,5 253 47,9 44,5 279 52,3 178 46,7 403 54,5 237 48,0 45,6 272 52,5 165 47,3 378 54,7 224 48,4 565 56,5 415 54,0 385 54,1 46,9 252 52,9 160 48,0 340 54,8 214 49,0 536 57,6 375 54,3 370 54,5 435 53,8 400 54,0 1000 1500 2000 2500 3000 4000 5000 6000 7000 136 53,6 163 49,2 330 55,0 213 50,0 482 58,6 345 55,0 350 55,1 140 51,1 252 56,4 198 51,1 447 59,2 319 55,8 337 55,6 175 51,7 448 59,8 308 56,9 330 55,9 340 60,5 314 58,1 335 56,4 307 60,2 346 57,3 255 62,8 328 59,5 150 63,5 280 61,5 193 65,0 Fan unit www.lmf.it m³/h 250 500 750 Min Pa 122 100 17 Med Max Pa 129 133 45,5 249 276 288 53,8 207 215 223 52,8 114 126 46,1 213 257 278 54,0 181 192 200 53,2 250 350 413 55,2 237 257 270 49,9 175 97 112 46,7 142 217 256 54,2 165 174 180 53,3 193 320 390 55,3 217 236 246 50,2 100 280 460 62,3 352 375 420 58,8 CTE 3v 576V 574V 696V 694V 616V 614V 726V Min Med Max Min Med Max Min Med Max Min Med Max Min Med Max Min Med Max dB(A) Pa Pa Pa dB(A) Pa Pa Pa dB(A) Pa Pa Pa dB(A) Pa Pa Pa dB(A) Pa Pa Pa dB(A) Pa Pa Pa dB(A) 44,7 372 385 450 58,7 1000 1500 2000 2500 20 54,8 138 163 174 53,6 120 163 53,9 109 55,4 3000 4000 5000 262 284 297 59,3 272 314 59,3 268 59,8 55 93 48,3 149 222 54,7 152 165 169 53,5 118 275 372 55,4 196 219 238 50,4 65 211 435 61,5 330 358 386 58,9 150 321 56,1 138 200 232 50,6 328 56,5 210 56,8 134 221 51,0 199 51,3 98 360 60,4 303 318 330 59,2 305 56,7 275 297 310 59,3 175 55,4 254 277 298 59,3 CTE Fan unit www.lmf.it 137 CTT INSIDE PARTIAL OUTSIDE Belt driven fan box from 1.500 to 16.000 m³/h Q General features The CTT units has been designed and manufactured to be installed in small and medium size ventilation plants. They are tted with pulley and belt driven fans and permit 1500 to 16000 m³/h air ow rate and up to 700 Pa external static pressure; therefore, it is possible to install long air ducts to extract or supply air from or to the rooms. Q Mechanical features The frame is made from galvanized steel. A side panel can be opened to inspect the unit. The acoustic insulation is obtained by an adequate thickness of polyester. CTT The fans are double inlet forward curved centrifugal type with statically and dynamically balanced wheels reducing vibrations and noise. Anti-vibrators, which attenuate any vibration transmission, have been placed between the frame and the motor-fan assembly. The three-phase electric motors, one speed (1V) or two speeds (2V) type, are hold on moving slides for adjusting the belt tightening. A cable gland is tted to the unit front panel for easy electrical connections. Q Accessories 138 Roof cover TP External hood CU Overpressure damper SG Supports H=90 mm PD Polarity switch (only for 2V) CDP Fan unit www.lmf.it Q Performances The following tables indicate, model by model and depending on the required air ow rate and external static pressure, the electrical power output [kW] and the sound pressure level at 1 m far from unit [dB(A)]. Q Model External static pressure (Pa) Air ow rate CTT CTT 809 CTT 810 CTT 919 CTT 1115 100 300 400 m³/h kW dB(A) kW dB(A) kW dB(A) 1500 0,18 53 0,18 58 0,37 63 kW 500 dB(A) kW 600 dB(A) kW 700 dB(A) dB(A) kW 2000 0,18 58 0,25 60 0,37 63 0,55 66 0,75 69 2500 0,25 63 0,37 63 0,55 65 0,75 67 0,75 69 1,1 71 1,1 73 3000 0,37 67 0,55 67 0,75 68 0,75 69 1,1 70 1,1 71 1,5 73 2000 0,18 55 0,25 59 0,37 63 3000 0,25 61 0,37 63 0,55 65 0,75 67 1,1 69 1,1 71 1,5 73 4000 0,55 67 0,75 68 1,1 69 1,1 70 1,5 71 1,5 73 2,2 74 4000 0,37 61 0,55 63 0,75 66 1,1 69 1,5 71 5000 0,55 66 0,75 67 1,1 68 1,5 70 1,5 71 2,2 73 2,2 75 6000 0,75 70 1,1 70 1,5 71 1,5 72 2,2 73 2,2 74 3,0 75 7000 1,1 73 1,5 73 2,2 74 2,2 74 2,2 75 3,0 76 3,0 76 7000 0,75 68 1,1 69 1,5 69 2,2 71 2,2 72 3,0 73 3,0 75 8000 1,1 71 1,5 71 1,5 71 2,2 72 2,2 74 3,0 75 3,0 76 9000 1,5 73 2,2 74 2,2 74 2,2 74 3,0 75 3,0 76 4,0 77 2,2 76 3,0 76 3,0 76 3,0 77 4,0 77 4,0 78 10000 3,0 79 4,0 79 4,0 80 5,5 80 5,5 80 5,5 81 9000 0,75 68 1,1 68 2,2 69 2,2 70 3,0 72 3,0 73 4,0 75 10000 1,1 70 1,5 70 2,2 70 2,2 71 3,0 73 4,0 74 4,0 75 12000 1,5 75 2,2 76 3,0 74 3,0 74 4,0 75 4,0 76 5,5 77 14000 2,2 78 3,0 78 4,0 78 4,0 78 5.,5 78 5,5 78 5,5 79 16000 3,0 81 4,0 81 4,0 81 5,5 81 5,5 81 7,5 82 7,5 82 12000 CTT 1218 200 Q Dimensions and weight CTT 810 912 1115 1218 mm 800 800 900 1100 1300 B mm 600 600 700 800 1100 E mm 272 299 351 414 478 F mm 308 340 340 480 558 Weight kg 60 65 65 70 70 80 100 120 170 CTT 809 A 180 F B E B A Fan unit www.lmf.it 139 SIL INSIDE Low noise fan unit from 200 to 7.000 m³/h Q General features The SIL series fan unit, tted with a relevant thickness of noise attenuation material, allows an extremely silent operation. This series is composed of ve direct driven fan models. With its different combination of fan size, fan speed and power supply, these units cover up to 7000 m³/h air ow rate range and up to 500 Pa static pressure range. The high external static pressure lets SIL units operate in very long air ducts. Q Mechanical features SIL The casing is made by galvanized sheet metal and the acoustic insulation is realized by breglass 50 mm thickness and internal drilled panels. The fans are double inlet forward curved centrifugal type with statically and dynamically balanced wheels reducing vibrations and noise. The motors are external rotor type (except SIL 450 6T), with built-in thermal protection contact. Anti-vibrators, which attenuate any vibration transmission, have been placed between the frame and the motor-fan assembly. Q Accessories 140 Single-phase electronic speed regulator RCS Auto transformer speed regulator VT Fan unit www.lmf.it Q Model SIL 160 2M 200 2M 250 2M 315 4M 355 4M 400 4M 450 6M 450 6T 1100 Shaft power W 45 90 140 184 420 550 515 Max current A 0,66 0,85 1,40 1,90 3,60 4,60 5,00 Fan speeds 2 1 1 1 1 1 1 2 Poles 2 2 2 4 4 4 6 6 20 54 32 55 55 55 55 20 B F F F F F F B V 230 230 230 230 230 230 230 230 400 ph 1 1 1 1 1 1 1 3 3 Hz 50 50 50 50 50 50 50 50 dB(A) 37÷43 39÷46 41÷47 42÷47 46÷53 46÷49 44÷45 46÷60 Protection class IP Isolation class Electrical power supply Sound pressure level at 1 m 7,80 4,50 Q Dimensions and weight SIL 160 200 250 315 355 400 450 A mm 400 400 400 550 550 650 750 B mm 400 400 400 550 550 650 750 C mm 450 450 450 550 550 650 750 D mm 160 200 250 315 355 400 450 E mm 275 250 250 300 300 378 430 Weight kg 17 20 25 33 35 39 46 SIL D D A E = B = C Fan unit www.lmf.it 141 Q Performances 41 dB(A) 37 dB(A) 45 dB(A) 350 43 dB(A) 300 250 39 dB(A) 150 43 dB(A) 100 50 0 100 200 300 400 SIL 250 2M 600 47 dB(A) 500 44 dB(A) 400 300 0 100 200 300 400 500 600 700 300 42 dB(A) SIL 315 4M 0 43 dB(A) 250 44 dB(A) 200 150 41 dB(A) 200 100 47 dB(A) 100 50 450 400 350 200 400 600 800 1000 1200 47,5 dB(A) 300 250 200 150 1000 1500 2000 49 dB(A) 550 500 47,5 dB(A) 450 400 53 dB(A) 350 46 dB(A) 300 100 50 0 500 0 500 600 46 dB(A) SIL 355 4M 0 SIL 400 4M 0 SIL 46 dB(A) 400 200 60 40 20 0 142 450 SIL 200 2M 200 180 160 140 120 100 80 SIL 160 2M The following diagrams indicate, model by model, the external static pressure [Pa] depending on the air ow rate [m³/h]. 250 200 1000 1500 2000 2500 3000 500 1000 1500 2000 2500 3000 Fan unit www.lmf.it 44 dB(A) 44,5 dB(A) 300 250 45 dB(A) 350 300 250 200 46 dB(A) 48 dB(A) 53 dB(A) 150 200 60 dB(A) 100 50 0 150 100 1000 450 400 SIL 450 6T 350 SIL 450 6M 400 2000 3000 4000 0 2000 4000 6000 8000 SIL Fan unit www.lmf.it 143 EKA INSIDE Low body fan box from 950 to 4.300 m³/h Q General features The EKA series fan units are characterized by their small dimensions and easy installation; for this reason they are suitable for home and commercial use inside false ceiling. The series is composed of 5 models covering an air ow rate range from 950 to 4300 m³/h. The use of three speed centrifugal fans with statically and dynamically balanced wheels allows vibrations and noise to be reduced to a minimum. EKA Q Mechanical features The casing is made by galvanized sheet metal. Unit insulation is obtained by an adequate thickness of polyethylene and polyester. The air lter, supplied as an option, is easily removable for cleaning and replacement. The units are supplied with onboard connector with relay board making electrical connections and fan control easy (except for EKA 10 model, because of very low power consumption). 144 Fan unit www.lmf.it Q Accessories External water heating coil section SRW 1 step post electric heater section SRE 2 step post electric heater section 2SRE G2 class plain lter section AF Supply plenum silenced section PAM Supply plenum with round adapter for circular duct section PBC Supply duct ange connection FM 3 step fan speed control CVU Control panel PCR Remotable temperature sensor for PCR NTC Q Model EKA 10 12 14 16 17 m³/h 950 1500 2100 3400 4300 Med m³/h 880 1370 1470 2300 3580 Min m³/h 750 1160 940 1560 3080 Max Pa 117 140 162 155 160 Med Pa 100 117 79 80 112 Min Pa 73 85 32 40 83 Max dB(A) 54,1 52,7 56,3 58,8 58,8 Med dB(A) 51,1 51,0 48,4 54,2 52,5 Min dB(A) 49,7 49,3 43,0 44,0 42,7 Shaft power W 90 147 184 420 600 Max current A 1 1,9 2,6 3,9 5,5 Fan speeds n° 3 3 3 3 3 Poles n° 4 4 4 4 4 Protection class IP 20 20 20 20 20 B B B B B Air ow External Static Pressure 1 m sound pressure level Isolation class Electrical power supply V/ph/Hz 230/1/50 Fan unit www.lmf.it EKA Max 145 Q Max fan speed air performances 350 16 17 External Static Pressure (Pa) 300 250 14 200 10 56,3 12 58,8 52,7 150 58,8 54,1 100 50 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Air ow (m³/h) Q Accessories SIL 10 12 14 16 17 EKA Water heating section SRW (inlet air temperature 20°C, water temperature 70/60°C) Heating capacity (at max fan speed) kW 7,9 13,2 17,6 27,5 31,9 Coil rows n° 2 2 2 2 2 Water side pressure drop kPa 12 18 17 25 33 Water ow rate m³/h 0,7 1,2 1,6 2,4 2,8 Electric heating section SRE kW 3 4,5 4,5 6 6 Electric heating section 2SRE kW 6 9 9 12 12 Electrical power supply V/ph/Hz 400/3+N/50 Circular duct supply connector PBC Diameter Ø n° of circular ducts 146 mm 200 200 200 200 200 n° 2 3 3 4 4 Fan unit www.lmf.it Q Dimensions and weight EKA 10 12 14 16 17 A mm 640 1000 1100 1340 1340 B mm 295 295 322 372 372 C mm 450 450 500 535 535 L1 mm 135 139 159 237 237 L2 mm 306 290 306 328 328 L3 mm - 186 170 210 210 L4 mm 199 95 159 237 237 L5 mm 137 135 151 238 238 L6 mm 140 136 144 114 114 Weight kg 15 24 30 42 42 L6 L5 L1 L2 L2 L4 B A C LMF S.p.A Via Paradiso, 33 36040 Meledo di Sarego (VI) - Italy air and water handling for a comfortable life www.ferrarogroup.eu Tel. +39 0444 821279 Fax +39 0444 820323 email: [email protected] www.lmf.it