Preview only show first 10 pages with watermark. For full document please download

Linear Displacement Sensors

   EMBED


Share

Transcript

Linear displacement sensors Selection guide Model CD50 CD60 Measurement range Up to 1250 mm Output Page Potentiometer (1kΩ) 4-5 Analog (0…10V / 4…20mA / 0…20mA) 6-7 Incremental 8-9 Potentiometer (1kΩ) 10 - 11 Analog (0…10V / 4…20mA / 0…20mA) 12 - 13 Incremental 14 - 15 Absolute (SSI / Profibus / CANopen / DeviceNet) 16 - 17 Potentiometer (1kΩ) 18 - 19 Analog (0…10V / 4…20mA / 0…20mA) 20 – 21 Incremental 22 – 23 Absolute (SSI / Profibus / CANopen / DeviceNet) 24 - 25 Mechanical devices (MEC) 26 - 27 Potentiometer (1kΩ) 28 - 29 Analog (0…10V / 4…20mA / 0…20mA) 30 - 31 Incremental 32 - 33 Absolute (SSI / Profibus / CANopen / DeviceNet) 34 - 35 Mechanical devices (MEC) 36 - 37 Potentiometer (1kΩ) 38 - 39 Analog (0…10V / 4…20mA / 0…20mA) 40 – 41 Incremental 42 – 43 Absolute (SSI / Profibus / CANopen / DeviceNet) 44 – 45 Mechanical devices (MEC) 46 - 47 Potentiometer (1kΩ) 48 - 49 Analog (0…10V / 4…20mA / 0…20mA) 50 - 51 Potentiometer (1kΩ) 52 - 53 Analog (0…10V / 4…20mA / 0…20mA) 54 - 55 Up to 1500 mm Up to 2000 mm CD80 Up to 2500 mm Up to 3000 mm CD115 Up to 3500 mm CD150 AS40 AS58 Up to 6000 mm 90° to 3600° 90° to 3600° We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 2 Selection guide Model CDS1210 CDS1215 CDS1820 CDS1830 CDS1840 CDS1850 Output connections Options Accessories Measurement range Up to 10 000 mm Up to 15 000 mm Up to 20 000 mm Up to 30 000 mm Up to 40 000 mm Up to 50 000 mm Output Page Potentiometer (1kΩ) 56 - 57 Analog (0…10V / 4…20mA / 0…20mA) 58 – 59 Mechanical devices (MEC) 60 – 61 Potentiometer (1kΩ) 62 – 63 Analog (0…10V / 4…20mA / 0…20mA) 64 – 65 Mechanical devices (MEC) 66 – 67 Potentiometer (1kΩ) 68 - 69 Analog (0…10V / 4…20mA / 0…20mA) 70 – 71 Mechanical devices (MEC) 72 -73 Potentiometer (1kΩ) 74 - 75 Analog (0…10V / 4…20mA / 0…20mA) 76 - 77 Mechanical devices (MEC) 78 - 79 Potentiometer (1kΩ) 80 - 81 Analog (0…10V / 4…20mA / 0…20mA) 82 - 83 Mechanical devices (MEC) 84 - 85 Potentiometer (1kΩ) 86 - 87 Analog (0…10V / 4…20mA / 0…20mA) 88 - 89 Mechanical devices (MEC) 90 - 91 Potentiometric version 84 Analog version 85 Incremental version 86 For draw-wire sensors, CD series 87 For draw-wire sensors, CDS series 88 Adapter flanges for draw-wire sensors, MEC type 89 Connectors 90 Mounting accessories 91 Accessories for optical encoders and angular sensors 92 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 3 CD50 potentiometric output – Measurement range up to 1250 mm Specifications: Measurement range Output signal Resolution Material 0 up to 1250 mm 1kΩ Potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,51 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,25% f.s. – stroke ≤500mm +/- 0,15% f.s. – stroke >500mm +/- 0,10% f.s. – stroke >500mm (option) IP54 (option IP67) 10 M/S 40 M/S2 (before cable deformation) ≈ 700 g -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 50 100 250 500 750 1000 1200 1250 Min. pull-out force Max. pull-out force ≈ 6,40 N ≈ 6,30 N ≈ 6,00 N ≈ 5,50 N ≈ 5,00 N ≈ 4,50 N ≈ 4,00 N ≈ 4,00 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N Ordering reference: CD50 OP Model CD50 Measurement range 0050 = 0 up to 50 mm 0100 = 0 up to 100 mm 0250 = 0 up to 250 mm 0500 = 0 up to 500 mm 0750 = 0 up to 750 mm 1000 = 0 up to 1000 mm 1200 = 0 up to 1200 mm 1250 = 0 up to 1250 mm (Other range available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L25 L15 L10 = +/- 0.25% f.s. (standard for measuring range from 0 to 500mm) = +/- 0.15% f.s. (standard for measuring range greater than 500 mm) (option for measuring range from 0 to 500mm) = +/- 0.10% f.s. (option for measuring range greater than 500 mm) Connection C L4 K = Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BT CP EM EN IP67 M4 RAC TEV = Complete anodizing = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Cable dust wiper = Water evacuation holes Reference example: CD50-0750-R01R-L15-K02-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 4 Dimensional drawing We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 5 CD50 analog output – Measurement range 0 up to 1250 mm Specifications: Measurement range Output signal 0 up to 1250 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,51 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,25% f.s. – stroke ≤500mm +/- 0,15% f.s. – stroke >500mm +/- 0,10% f.s. – stroke >500mm (option) IP54 (option IP67) 10 M/S 40 M/S2 (before cable deformation) ≈ 700 g -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 50 100 250 500 750 1000 1200 1250 Min. pull-out force Max. pull-out force ≈ 6,40 N ≈ 6,30 N ≈ 6,00 N ≈ 5,50 N ≈ 5,00 N ≈ 4,50 N ≈ 4,00 N ≈ 4,00 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N Ordering reference: CD50 OP Model CD50 Measurement range 0050 = 0 up to 50 mm 0100 = 0 up to 100 mm 0250 = 0 up to 250 mm 0500 = 0 up to 500 mm 0750 = 0 up to 750 mm 1000 = 0 up to 1000 mm 1200 = 0 up to 1200 mm 1250 = 0 up to 1250 mm (Other range available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L25 L15 L10 = +/- 0.25% f.s. (standard for measuring range from 0 up to 500mm) = +/- 0.15% f.s. (standard for measuring range greater than 500 mm) (option for measuring range from 0 up to 500mm) = +/- 0.10% f.s. (option for measuring range greater than 500 mm) Connection C L4 K = Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BT CP EM EN IP67 M4 RAC TEV = Complete anodizing = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Cable dust wiper = Water evacuation holes Reference example: CD50-0750-U010-L15-K02-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 6 Dimensional Drawing 18 6 30,50 49 75,50 49 40 110 34,50 6,50 30 15 49 110 70 K Connection (PVC cable - 4 wires) L4 connection (connector M12 - 4 pin) C connection (Connector M16 - DIN 8 pin ) 5 30 60 2,50 2x 12,50 17,50 20 14,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 7 4,50 CD50 incremental output - Measurement range 0 to 1250 mm Specifications: Measurement range Sensing device Supply and output signal 0 up to 1250 mm Incremental encoder 2G2 (5Vdc – Driver 5Vdc RS422) 5G5 (11 to 30Vdc – Push-pull) 9G5 (5 to 24Vdc – Push-pull) PG5 (5 to 30Vdc – Push-pull) 1 – 5 – 10 – 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,51 mm Male connector M16 – DIN 8 pin Male connector M16 – DIN 5 pin PVC cable – 8 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 10 M/S 40 M/S2 (before cable deformation) ≈ 700 g -20° to +80°C -30° to +80°C Resolution Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 1250 Min. pull-out force ≈ 4,00 N Max. pull-out force ≈ 6,50 N Ordering reference: CD50 OP Model CD50 Measurement range 1250 = 0 à 1250 mm (Or other ranges between 0 and 1250 mm) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other range available on demand) Supply and output stage 2G2 5G5 9G5 PG5 = 5Vdc – Driver 5Vdc RS422 = 11 to 30Vdc – Push-pull = 5 to 24Vdc – Push-pull = 5 to 30Vdc – Push-pull Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection GDA G2A G3R G3A = Male connector M16 – DIN 8 pin = Male connector M16 – DIN 5 pin = PVC cable - 8 wires - radial + ex: 020 for cable 2 meters long = PVC cable - 8 wires - axial + ex: 020 for cable 2 meters long OP options AC BT CP EM EN M4 RAC TEV = Complete anodizing = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Fixing of the measuring cable with a M4 threaded rod = Cable dust wiper = Water evacuation holes Reference example: CD50-1250-05-PG5-L05-GDA-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 8 Dimensional drawing We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 9 CD60 potentiometric output – Measurement range 0 up to 1500 mm Specifications: Measurement range Output signal Resolution Material 0 up to 1500 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 20 m/s2 (before cable deformation) ≈ 1000 g -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 1500 Min. pull-out force Max. pull-out force ≈ 9,00 N ≈ 12,00 N Ordering reference: CD60 OP Model CD60 Measurement range 1500 = 0 up to 1500 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP EM EN IP67 M4 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD60-1500-R01K-L15-K02-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 10 6,50 18 59 8 97,50 59 58 132 34,50 Dimensional Drawing 60 59 19 90 161 C connection (Connector M16 - DIN 3 pin ) 76 7 L4 connection (connector M12 - 4 pin) 2 42 4,75 23,75 K connection (PVC cable - 4 wires) 4x 11,50 16,50 20 15,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 11 6,50 CD60 analog output – Measurement range 0 up to 1500 mm Specifications: Measurement range Output signal 0 up to 1500 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 20 m/s2 (before cable deformation) ≈ 1000 g -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 1500 Min. pull-out force Max. pull-out force ≈ 9,00 N ≈ 12,00 N Ordering reference: CD60 OP Model CD60 Measurement range 1500 = 0 up to 1500 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP EM EN IP67 M4 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD60-1500-U010-L15-K02-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 12 6,50 18 59 8 97,50 59 58 132 34,50 Dimensional Drawing 60 59 19 90 161 C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin) 76 7 2 42 4,75 23,75 K connection (PVC cable - 4 wires) 4x 11,50 16,50 20 15,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 13 6,50 CD60 incremental output - Measurement range 0 up to 1500 mm Specifications: Measurement range Sensing device Supply and output stage 0 up to 1500 mm Incremental encoder 2G2 (5Vdc - Driver 5Vdc RS422) PG5 (5 to 30Vdc - Push-pull 5-30Vdc) RG2 (4.75 to 30Vdc - Driver 5Vdc RS422) 5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc) 1 - 5 - 10 - 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW PUR cable – 12 wires PVC cable – 8 wires +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 Cable forces: 10 M/S 20 M/S2 (before cable deformation) Measurement ≈ 1000 g range in mm -20° to +85°C 1500 -40° to +85°C Resolution Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Min. pull-out force ≈ 9,00 N Max. pull-out force ≈ 12,00 N Ordering reference: CD60 OP Model CD60 Measurement range 1500 = 0 to 1500 mm (Other ranges available on demand) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other values on demand) Supply and output stage 2G2 PG5 RG2 5GT = 5Vdc - Driver 5Vdc RS422 = 5 to 30Vdc - Push-pull 5-30Vdc = 4.75 to 30Vdc - Driver 5Vdc RS422 = 11 to 30Vdc - Transistorized push-pull 11-30Vdc Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection G6R G8R GP G3 = Male connector M23 – 12 pin CW = Male connector M23 – 12 pin CCW = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long OP options AC BR CP EM EN M4 TEV = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD60-1500-05-PG5-L05-G6R-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 14 6,50 18 8 37,50 59 97,50 59 58,50 132 34,50 Dimensional Drawing 60 59 19 90 106,50 119,41 With DHM5 encoder GPR or G3R connection (PUR cable - 12 wires or PVC cable - 8 wires ) With DHM5 encoder G6R or G8R connection (Male connector M23 - 12 pin CW or CCW) 7 52,50 4x 6,50 40,75 2 40,75 42 4,75 23,75 76 15,50 54 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 15 CD60 absolute output - Measurement range 0 up to 1500 mm Specifications: Measurement range Sensing device Supply 0 up to 1500 mm Absolute encoder (PHM5 or MHM5 series) 10 - 30Vdc (MHM5) 5 - 30Vdc (PHM5) SSI Profibus CANopen DeviceNet 13 bits = 8192steps/turns 150 mm 152,4 mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW Terminal box +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 10 m/s 20 m/s² (before cable deformation) ≈ 1000 g -20° to +85°C -40° to +85°C Interface Resolution Distance per turns Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 1500 Min. pull-out force ≈ 9,00 N Max. pull-out force ≈ 12,00 N Ordering reference: CD60 OP Model CD60 Measurement range 1500 = 0 to 1500 mm (Other ranges available on demand) Distance per turns 150 152 = 150 mm = 152,4 mm Interface SSI/1 SSI/2 PROF CAN DEV = MHM5 Serial transmission (SSI) = PHM5 Serial transmission (SSI) = MHM5 Profibus transmission = MHM5 CANopen transmission = MHM5 DeviceNet transmission Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection H3P 0CC PRL S6R S8R = Terminal box (only for MHM5 Profibus and CANopen) = Terminal box (only for MHM5 DeviceNet) = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI) = 12 pins M23 connector - clockwise (only on PHM5 SSI) = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI) OP options AC BR CP EM EN M4 TEV = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD60-1500-152-PROF-L05-H3P-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 16 6,50 18 60 20 17,50 8 20 59 59 97,50 132 34,50 Dimensional Drawing 59 19 90 175 version 0CC 160 version H3P With MHM5 - SSI encoder PRL connection (Male connector M23 - 12 pin CCW) 76 7 4x 6,50 94,25 version 0CC 79,75 version H3P 39,75 48,75 2 136 124,50 42 4,75 23,75 With PHM5 - SSI encoder S6R or S8R connection (Male connector M23 - 12 pin CW or CCW) With MHM5 - PROF/CANO/DNET encoder 0CC or H3P connection (Terminal box) 15,50 72,20 51 58,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 17 CD80 potentiometric output – Measurement range 0 up to 2000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 2000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 8 m/s2 (before cable deformation) ≈ 1500 g -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 2000 Min. pull-out force Max. pull-out force ≈ 8,00 N ≈ 11,00 N Ordering reference: CD80 OP Model CD80 Measurement range 2000 = 0 up to 2000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP EM IP67 M4 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD80-2000-R01K-L15-K02-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 18 18 6,50 79 8 117,50 59 58 152 34,50 Dimensional Drawing 50 29,50 79 161 120 C connection (Connector M16 - DIN 3 pin ) 100 L4 connection (connector M12 - 4 pin) 10 9 25 54,50 K connection (PVC cable - 4 wires) 2x 11,50 16,50 20 18,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 19 6,50 CD80 analog output – Measurement range 0 up to 2000 mm Specifications: Measurement range Output signal 0 up to 2000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 8 m/s2 (before cable deformation) ≈ 1500 g -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 2000 Min. pull-out force Max. pull-out force ≈ 8,00 N ≈ 11,00 N Ordering reference: CD80 OP Model CD80 Measurement range 2000 = 0 up to 2000 mm (Other range available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP EM IP67 M4 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD80-2000-U010-L15-K02-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 20 18 6,50 79 8 117,50 59 58 152 34,50 Dimensional Drawing 50 29,50 79 161 120 L4 connection (connector M12 - 4 pin) 100 10 9 25 54,50 K connection (PVC cable - 4 wires) C connection (Connector M16 - DIN 8 pin ) 2x 11,50 16,50 20 18,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 21 6,50 CD80 incremental output - Measurement range 0 up to 2500 mm Specifications: Measurement range Sensing device Supply and output stage 0 up to 2500 mm Incremental encoder 2G2 (5Vdc - Driver 5Vdc RS422) PG5 (5 to 30Vdc - Push-pull 5-30Vdc) RG2 (4.75 to 30Vdc - Driver 5Vdc RS422) 5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc) 1 - 5 - 10 - 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW PUR cable - 12 wires PVC cable - 8 wires +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 Cable forces: 10 m/s 8 m/s2 (before cable deformation) Measurement ≈ 1500 g range in mm -20° to +85°C 2500 -40° to +85°C Resolution Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Min. pull-out force ≈ 7,50 N Max. pull-out force ≈ 11,00 N Ordering reference: CD80 OP Model CD80 Measurement range 2500 = 0 up to 2500 mm (Other ranges available on demand) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other values on-demand) Supply and output stage 2G2 PG5 RG2 5GT = 5Vdc - Driver 5Vdc RS422 = 5 to 30Vdc - Push-pull 5-30Vdc = 4.75 to 30Vdc - Driver 5Vdc RS422 = 11 to 30Vdc - Transistorized push-pull 11-30Vdc Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection G6R G8R GP G3 = Male connector M23 – 12 pin CW = Male connector M23 – 12 pin CCW = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long OP options AC BR CP EM M4 TEV = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD80-2500-05-PG5-L05-G6R-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 22 18 6,50 8 47,50 117,50 79 59 152 34,50 Dimensional Drawing 50 29,50 79 106,50 120 119,40 With DHM5 encoder G6R or G8R connection (Male connector M23 - 12 pin CW or CCW) 100 10 54,50 With DHM5 encoder GPR or G3R connection (PUR cable - 12 wires or PVC cable - 8 wires ) 52 51 9 25 2x 18,50 52,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 54 23 6,50 CD80 absolute output - Measurement range 0 up to 2500 mm Specifications: Measurement range Sensing device Supply 0 up to 2500 mm Absolute encoder (PHM5 or MHM5 series) 10 - 30Vdc (MHM5) 5 - 30Vdc (PHM5) SSI Profibus CANopen DeviceNet 13 bits = 8192steps/turns 200 mm 204,8 mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW Terminal box +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 10 m/s 8 m/s2 (before cable deformation) ≈ 1500 g -20° to +85°C -40° to +85°C Interface Resolution Distance per turns Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 2500 Min. pull-out force ≈ 7,50 N Max. pull-out force ≈ 11,00 N Ordering reference: CD80 OP Model CD80 Measurement range 2500 = 0 à 2500 mm (Other ranges available on demand) Distance per turns 200 204 = 200 mm = 204,8 mm Interface SSI/1 SSI/2 PROF CAN DEV = MHM5 Serial transmission (SSI) = PHM5 Serial transmission (SSI) = MHM5 Profibus transmission = MHM5 CANopen transmission = MHM5 DeviceNet transmission Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection H3P 0CC PRL S6R S8R = Terminal box (only for MHM5 Profibus and CANopen) = Terminal box (only for MHM5 DeviceNet) = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI) = 12 pins M23 connector - clockwise (only on PHM5 SSI) = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI) OP options AC BR CP EM M4 TEV = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD80-2500-204-PROF-L05-H3P-OP-AC-EM We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 24 18 6,50 20 8 27,50 20 79 59 117,50 152 34,50 Dimensional Drawing 50 29,50 79 120 175 version 0CC 160 version H3P With MHM5 - SSI encoder PRL connection (Male connector M23 - 12 pin CCW) 100 10 54,50 With PHM5 - SSI encoder S6R or S8R connection (Male connector M23 - 12 pin CW or CCW) With MHM5 - PROF/CANO/DNET encoder H3P or 0CC connection (Terminal box) 105,50 version 0CC 91 version H3P 60 51 136 9 124,50 25 2x 18,50 72,20 51 58,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 25 6,50 CD80-MEC mechanical devices - Measurement range 0 up to 2500 mm Specifications: Measurement range Circumference drum 0 up to 2500 mm 200 mm/turn 204,8 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 8 m/s2 (before cable deformation) ≈ 1500 g -20° to +80°C -30° to +80°C Sensing device Material Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 2500 Min. pull-out force ≈ 7,50 N Max. pull-out force ≈ 11,00 N Ordering reference: CD80 MEC OP Model CD80-MEC Measurement range 2500 = 0 up to 2500 mm (Other range available on demand) Drum circumference 200 204 = 200 mm/turn = 204,8 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR CP EM M4 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CD80-MEC-2500-200-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 26 Dimensional Drawing 6,50 34,50 18 8 47,50 117,50 79 59 152 Oldham coupling adaptable to the detection element that will be mounted (see options) 50 29,50 +0,05 50 +0,02 127,40 79 120 54,50 100 10 9 25 2x 18,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 27 6,50 CD115 potentiometric output – Measurement range 0 up to 3000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 3000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10m/s 7 m/s2 (before cable deformation) ≈ 2000 g -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 3000 Min. pull-out force Max. pull-out force ≈ 13,50 N ≈ 18,00 N Ordering reference: CD115 OP Model CD115 Measurement range 3000 = 0 up to 3000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M4 TEV BR = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes = Cleaning brush for the cable Reference example: CD115-3000-R01K-L15-K02-OP-AC-M4 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 28 Dimensional Drawing 6,50 8 65,50 153,50 115 89 58 188 34,50 18 50 31 115 162 155 K connection (PVC cable - 4 wires) C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) 10 25 56 135 7,50 2x 11,50 16,50 20 20,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 29 6,50 CD115 analog output – Measurement range 0 up to 3000 mm Specifications: Measurement range Output signal 0 up to 3000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,61 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 M/S 7 M/S2 (before cable deformation) ≈ 2000 g -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 3000 Min. pull-out force Max. pull-out force ≈ 13,50 N ≈ 18,00 N Ordering reference: CD115 OP Model CD115 Measurement range 3000 = 0 up to 3000 mm (Other range available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M4 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD115-3000-U010-L15-K02-OP-AC-M4 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 30 Dimensional Drawing 6,50 8 65,50 153,50 115 89 58 188 34,50 18 50 31 115 162 155 C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin) 135 10 25 56 K connection (PVC cable - 4 wires) 7,50 2x 11,50 16,50 20 20,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 31 6,50 CD115 incremental output - Measurement range 0 up to 3500 mm Specifications: Measurement range Sensing device Supply and output stage 0 up to 3500 mm Incremental encoder 2G2 (5Vdc - Driver 5Vdc RS422) PG5 (5 to 30Vdc - Push-pull 5-30Vdc) RG2 (4.75 to 30Vdc - Driver 5Vdc RS422) 5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc) 1 - 5 - 10 - 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW PUR cable – 12 wires PVC cable – 8 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 Cable forces: 10 m/s 7 m/s2 (before cable deformation) Measurement ≈ 2000 g range in mm -20° to +85°C 3500 -40° to +85°C Resolution Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Min. pull-out force ≈ 13,00 N Max. pull-out force ≈ 18,00 N Ordering reference: CD115 OP Model CD115 Measurement range 3500 = 0 up to 3500 mm (Other ranges available on demand) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other values on demand) Supply and output stage 2G2 PG5 RG2 5GT = 5Vdc - Driver 5Vdc RS422 = 5 to 30Vdc - Push-pull 5-30Vdc = 4.75 to 30Vdc - Driver 5Vdc RS422 = 11 to 30Vdc - Transistorized push-pull 11-30Vdc Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection G6R G8R GP G3 = Male connector M23 – 12 pin CW = Male connector M23 – 12 pin CCW = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long OP options AC BR CP M4 TEV = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD115-3500-05-PG5-L05-G6R-OP-AC-M4 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 32 Dimensional Drawing 6,50 8 65,50 115 153,50 89 188 34,50 18 50 31 115 120,50 155 With DHM5 encoder GPR or G3R connection (PUR cable - 12 wires or PVC cable - 8 wires ) With DHM5 encoder G6R or G8R connection (Male connector M23 - 12 pin CW or CCW) 10 56 135 51,50 7,50 51,50 25 2x 20,50 52,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 54 33 6,50 CD115 absolute output - Measurement range 0 up to 3500 mm Specifications: Measurement range Sensing device Supply 0 up to 3500 mm Absolute encoder (PHM5 or MHM5 series) 10 - 30Vdc (MHM5) 5 - 30Vdc (PHM5) SSI Profibus CANopen DeviceNet 13 bits = 8192steps/turns 300 mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW Terminal box +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 10 M/S 7 M/S2 (before cable deformation) ≈ 2000 g -20° to +85°C -40° to +85°C Interface Resolution Distance per turns Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 3500 Min. pull-out force ≈ 13,00 N Max. pull-out force ≈ 18,00 N Ordering reference: CD115 OP Model CD115 Measurement range 3500 = 0 à 3500 mm (Other range available on demand) Distance per turns 300 = 300 mm Interface SSI/1 SSI/2 PROF CAN DEV = MHM5 Serial transmission (SSI) = PHM5 Serial transmission (SSI) = MHM5 Profibus transmission = MHM5 CANopen transmission = MHM5 DeviceNet transmission Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection H3P 0CC PRL S6R S8R = Terminal box (only for MHM5 Profibus and CANopen) = Terminal box (only for MHM5 DeviceNet) = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI) = 12 pins M23 connector - clockwise (only on PHM5 SSI) = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI) OP options AC BR CP M4 TEV = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD115-3500-300-PROF-L05-H3P-OP-AC-M4 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 34 Dimensional Drawing 6,50 20 20 8 45,50 153,50 115 60 89 188 34,50 18 50 31 115 155 176 version 0CC 161 version H3P With MHM5 - SSI encoder PRL connection (Male connector M23 - 12 pin CCW) 135 10 2x 105 version 0CC 90,50 version H3P 7,50 51 59,50 137 125,50 25 56 With PHM5 - SSI encoder S6R or S8R connection (Male connector M23 - 12 pin CW or CCW) With MHM5 - PROF/CANO/DNET encoder 0CC or H3P connection (Terminal box) 20,50 72,20 51 58,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 35 6,50 CD115-MEC mechanical devices - Measurement range 0 up to 3500 mm Specifications: Measurement range Circumference drum Sensing device Material 0 up to 3500 mm 300 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 7 m/s2 (before cable deformation) ≈ 2000 g -20° to +80°C -30° to +80°C Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 3500 Min. pull-out force ≈ 13,00 N Max. pull-out force ≈ 18,00 N Ordering reference: CD115 MEC OP Model CD115-MEC Measurement range 3500 = 0 up to 3500 mm (Other ranges available on demand) Drum circumference 300 = 300 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR CP M4 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CD115-MEC-3500-300-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 36 Dimensional Drawing 6,50 Oldham coupling adaptable to the detection element that will be mounted (see options) 8 65,50 115 188 89 153,50 34,50 18 50 +0,05 31 50 +0,02 128,40 115 155 135 10 7,50 25 56 2x 20,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 37 6,50 CD150 potentiometric output – Measurement range 0 up to 6000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 6000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 5 m/s2 (before cable deformation) ≈ 3000 g -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 4000 6000 Min. pull-out force Max. pull-out force ≈ 11,00 N ≈ 10,00 N ≈ 13,50 N ≈ 13,50 N Ordering reference: CD150 OP Model CD150 Measurement range 4000 = 0 up to 4000 mm 6000 = 0 up to 6000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M4 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD150-4000-R01K-L15-K02-OP-AC-M4 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 38 Dimensional Drawing 18 6,50 8 82 148 221 89 58 186,50 34,50 Measurement range up to 4000 mm 60 30,25 148 171,50 186 C connection (Connector M16 - DIN 3 pin ) 170 L4 connection (connector M12 - 4 pin) 8 12,25 44 38,25 8 K connection (PVC cable - 4 wires) 4x 6,50 16,50 11,50 20 20,25 Measuring range greater than 4000 mm up to 6000 mm 6,50 8 108 148 186,50 89 120 221 34,50 18 60 30,25 148 138 186 C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) 170 8 20 12,25 44 38,25 8 K connection (PVC cable - 4 wires) 4x We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 11,50 16,50 20,25 39 6,50 CD150 analog output – Measurement range 0 up to 6000 mm Specifications: Measurement range Output signal 0 up to 6000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 5 m/s2 (before cable deformation) ≈ 3000 g -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 4000 6000 Min. pull-out force Max. pull-out force ≈ 11,00 N ≈ 10,00 N ≈ 13,50 N ≈ 13,50 N Ordering reference: CD150 OP Model CD150 Measurement range 4000 = 0 up to 4000 mm 6000 = 0 up to 6000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M4 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD150-4000-U010-L15-K02-OP-AC-M4 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 40 18 6,50 8 82 148 89 58 221 Measurement range up to 4000 mm 186,50 34,50 Dimensional Drawing 60 30,25 148 171,50 186 C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin) 170 8 12,25 44 38,25 8 K connection (PVC cable - 4 wires) 4x 6,50 11,50 16,50 20 20,25 Measuring range greater than 4000 mm up to 6000 mm 6,50 8 108 148 221 89 120 186,50 34,50 18 60 30,25 148 138 186 C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin) 170 8 20 12,25 44 38,25 8 K connection (PVC cable - 4 wires) 4x We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 11,50 16,50 20,25 41 6,50 CD150 incremental output - Measurement range 0 up to 6000 mm Specifications: Measurement range Sensing device Supply and output stage 0 up to 6000 mm Incremental encoder 2G2 (5Vdc - Driver 5Vdc RS422) PG5 (5 to 30Vdc - Push-pull 5-30Vdc) RG2 (4.75 to 30Vdc - Driver 5Vdc RS422) 5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc) 1 - 5 - 10 - 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW 12-wires PUR cable 8-wires PVC cable +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 Cable forces: 10 M/S 5 M/S2 (before cable deformation) Measurement ≈ 3000 g range in mm -20° to +85°C 6000 -40° to +85°C Resolution Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Min. pull-out force ≈ 10,00 N Max. pull-out force ≈ 13,50 N Ordering reference: CD150 OP Model CD150 Measurement range 6000 = 0 up to 6000 mm (Other ranges available on demand) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other values on demand) Supply and output stage 2G2 PG5 RG2 5GT = 5Vdc - Driver 5Vdc RS422 = 5 to 30Vdc - Push-pull 5-30Vdc = 4.75 to 30Vdc - Driver 5Vdc RS422 = 11 to 30Vdc - Transistorized push-pull 11-30Vdc Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection G6R G8R GP G3 = Male connector M23 – 12 pin CW = Male connector M23 – 12 pin CCW = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long OP options AC BR BT CP M4 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD150-6000-05-PG5-L05-G6R-OP-AC-M4 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 42 18 6,50 8 82 148 221 89 58,50 186,50 34,50 Dimensional Drawing 60 30,25 148 130 186 With DHM5 encoder GPR or G3R connection (PUR cable - 12 wires or PVC cable - 8 wires ) With DHM5 encoder G6R or G8R connection (Male connector M23 - 12 pin CW or CCW) 8 8 4x 34,75 12,25 34,75 44 38,25 170 20,25 52,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 54 43 6,50 CD150 absolute output - Measurement range 0 up to 6000 mm Specifications: Measurement range Sensing device Supply 0 up to 6000 mm Absolute encoder (PHM5 or MHM5 series) 10 - 30Vdc (MHM5) 5 - 30Vdc (PHM5) SSI Profibus CANopen DeviceNet 13 bits = 8192steps/turns 409,6 mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW Terminal box +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 10 M/S 5 M/S2 (before cable deformation) ≈ 3000 g -20° to +85°C -40° to +85°C Interface Resolution Distance per turns Material Cable diameter Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 6000 Min. pull-out force ≈ 10,00 N Max. pull-out force ≈ 13,50 N Ordering reference: CD150 OP Model CD150 Measurement range 6000 = 0 à 6000 mm (Other ranges available on demand) Distance per turns 409 = 409,6 mm Interface SSI/1 SSI/2 PROF CAN DEV = MHM5 Serial transmission (SSI) = PHM5 Serial transmission (SSI) = MHM5 Profibus transmission = MHM5 CANopen transmission = MHM5 DeviceNet transmission Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) Connection H3P 0CC PRL S6R S8R = Terminal box (only for MHM5 Profibus and CANopen) = Terminal box (only for MHM5 DeviceNet) = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI) = 12 pins M23 connector - clockwise (only on PHM5 SSI) = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI) OP options AC BR CP M4 TEV = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes Reference example: CD150-6000-409-PROF-L05-H3P-OP-AC-M4 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 44 Dimensional Drawing 6,50 20 20 8 62 186,50 148 60 89 221 34,50 18 30,25 148 185,50 version 0CC 170,50 version H3P With MHM5 - PROF/CANO/DNET encoder 0CC or H3P connection (Terminal box) 170 8 4x 44 12,25 42,75 146,50 33,50 135 8 With MHM5 - SSI encoder PRL connection (Male connector M23 - 12 pin CCW) 38,25 With PHM5 - SSI encoder S6R or S8R connection (Male connector M23 - 12 pin CW or CCW) 186 88,25 version 0CC 73,75 version H3P 60 20,25 72,20 51 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 45 6,50 CD150-MEC mechanical devices - Measurement range 0 up to 6000 mm Specifications: Measurement range Circumference drum Sensing device Material 0 up to 6000 mm 409,6 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 5 m/s2 (before cable deformation) ≈ 3000 g -20° to +80°C -30° to +80°C Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 6000 Min. pull-out force ≈ 10,00 N Max. pull-out force ≈ 13,50 N Ordering reference: CD150 MEC OP Model CD150-MEC Measurement range 6000 = 0 up to 6000 mm (Other ranges available on demand) Drum circumference 409 = 409,6 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR CP M4 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CD150-MEC-6000-409-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 46 Dimensional Drawing 6,50 8 82 186,50 Oldham coupling adaptable to the detection element that will be mounted (see options) 148 89 78 221 34,50 18 60 +0,05 30,25 50 +0,02 137,90 148 186 8 8 44 38,25 170 12,25 4x 20,25 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 47 6,50 CDS1210 potentiometric output – Measurement range 0 up to 10 000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 10 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 5 m/s2 (before cable deformation) ≈ 6 kg -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 10 000 Min. pull-out force Max. pull-out force ≈ 10,50 N ≈ 15,00 N Ordering reference: CDS1210 OP Model CDS1210 Measurement range 10000 = 0 up to 10 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1210-10000-R01K-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 48 114 8 94 128 120 120 Dimensional Drawing 102 66 120 216 135 C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) 47 115 10 84,50 18,50 K connection (PVC cable - 4 wires) 20,20 30 60 40 10 30 40,50 132 Modular base plate 68 172,50 11,50 11,50 16,50 20 9 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 49 CD1210 analog output – Measurement range 0 up to 10 000 mm Specifications: Measurement range Output signal 0 up to 10 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 8 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 M/S 5 M/S2 (before cable deformation) ≈ 6 kg -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 10 000 Min. pull-out force Max. pull-out force ≈ 11,00 N ≈ 13,50 N Ordering reference: CDS1210 OP Model CDS1210 Measurement range 10000 = 0 up to 10 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 8 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1210-10000-U010-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 50 114 8 94 128 120 120 Dimensional Drawing 102 66 120 135 216 K connection (PVC cable - 4 wires) C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin) 47 84,50 10 18,50 115 20,20 30 40 60 10 30 40,50 130,50 Modular base plate 68 172,50 11,50 11,50 16,50 20 9 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 51 CDS1210-MEC mechanical devices - Measurement range 0 up to 10 000 mm Specifications: Measurement range Circumference drum Sensing device Material 0 up to 10 000 mm 300 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 5 m/s2 (before cable deformation) ≈ 6kg -20° to +80°C -30° to +80°C Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 10 000 Min. pull-out force ≈ 10,50 N Max. pull-out force ≈ 15,00 N Ordering reference: CDS1210 MEC OP Model CDS1210-MEC Measurement range 10000 = 0 up to 10 000 mm (Other ranges available on demand) Drum circumference 300 = 300 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR BT CP M6 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CDS1210-MEC-10000-300-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 52 Dimensional Drawing +0,05 Oldham coupling adaptable to the detection element that will be mounted (see options) 8 68 114 128 120 50 +0,02 102 66 120 181 135 Modular base plate 47 11,50 84,50 10 18,50 115 20,20 68 30 60 40 132 10 172,50 30 9 40,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 53 CDS1215 potentiometric output – Measurement range 0 up to 15 000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 15 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 4 m/s2 (before cable deformation) ≈ 8 kg -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 15 000 Min. pull-out force Max. pull-out force ≈ 10,50 N ≈ 15,00 N Ordering reference: CDS1215 OP Model CDS1215 Measurement range 15000 = 0 up to 15 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1215-15000-R01K-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 54 114 8 94 128 120 120 Dimensional Drawing 137,50 120 128 135 311,50 C connection (Connector M16 - DIN 3 pin ) K connection (PVC cable - 4 wires) L4 connection (connector M12 - 4 pin) 47 10 52,50 10 180,50 115 20,20 30 60 40 30 11,50 16,50 20 9 40,50 Modular base plate 132 68 172,50 11,50 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 55 CD1215 analog output – Measurement range 0 up to 15 000 mm Specifications: Measurement range Output signal 0 up to 15 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 8 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 4 m/s2 (before cable deformation) ≈ 8 kg -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 15 000 Min. pull-out force Max. pull-out force ≈ 10,50 N ≈ 15,00 N Ordering reference: CDS1215 OP Model CDS1215 Measurement range 15000 = 0 up to 15 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 8 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1215-15000-U010-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 56 114 8 94 128 120 120 Dimensional Drawing 137,50 120 128 135 311,50 K connection (PVC cable - 4 wires) C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin) 47 10 52,50 10 180,50 115 20,20 30 60 40 30 11,50 16,50 20 9 40,50 Modular base plate 68 172,50 132 11,50 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 57 CDS1215-MEC mechanical devices - Measurement range 0 up to 15 000 mm Specifications: Measurement range Circumference drum Sensing device Material 0 up to 15 000 mm 300 mm/turn Adaptable with all of our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 4 m/s² (before cable deformation) ≈ 8kg -20° to +80°C -30° to +80°C Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 15 000 Min. pull-out force ≈ 10,50 N Max. pull-out force ≈ 15,00 N Ordering reference: CDS1215 MEC OP Model CDS1215-MEC Measurement range 15000 = 0 up to 15 000 mm (Other ranges available on demand) Drum circumference 300 = 300 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR BT CP M6 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CDS1215-MEC-15000-300-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 58 Dimensional Drawing +0,05 Oldham coupling adaptable to the detection element that will be mounted (see options) 8 68 114 128 120 50 +0,02 137,50 120 128 135 276,50 47 115 Modular base plate 10 52,50 10 132 172,50 180,50 11,50 20,20 30 60 40 30 9 40,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 59 CDS1820 potentiometric output – Measurement range 0 up to 20 000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 20 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 2 m/s2 (before cable deformation) ≈ 12 kg -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 20 000 Min. pull-out force Max. pull-out force ≈ 15,00 N ≈ 30,00 N Ordering reference: CDS1820 OP Model CDS1820 Measurement range 20000 = 0 up to 20 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1820-20000-R01K-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 60 126 179 190 180 120 Dimensional Drawing 154,50 180 200 10 110 317,50 C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) 180 10 20 174,50 K connection (PVC cable - 4 wires) 30 38 60 80 10 20 9 11,50 16,50 20 17,50 48,50 170 100 218,50 Modular base plate 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 61 CD1820 analog output – Measurement range 0 up to 20 000 mm Specifications: Measurement range Output signal 0 up to 20 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 8 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 2 m/s2 (before cable deformation) ≈ 12 kg -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 20 000 Min. pull-out force Max. pull-out force ≈ 15,00 N ≈ 30,00 N Ordering reference: CDS1820 OP Model CDS1820 Measurement range 20000 = 0 up to 20 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 8 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1820-20000-U010-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 62 126 179 190 180 120 Dimensional Drawing 154,50 180 200 10 110 317,50 C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) 180 10 20 174,50 K connection (PVC cable - 4 wires) 30 38 60 80 10 20 9 11,50 16,50 20 17,50 48,50 170 100 218,50 Modular base plate 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 63 CDS1820-MEC mechanical devices - Measurement range 0 up to 20 000 mm Specifications: Measurement range Circumference drum Sensing device Material 0 up to 20 000 mm 500 mm/turn Adaptable with all of our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 2 m/s2 (before cable deformation) ≈ 12kg -20° to +80°C -30° to +80°C Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 20 000 Min. pull-out force ≈ 15,00 N Max. pull-out force ≈ 30,00 N Ordering reference: CDS1820 MEC OP Model CDS1820-MEC Measurement range 20 000 = 0 up to 20 000 mm (Other ranges available on demand) Drum circumference 500 = 500 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR BT CP M6 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CDS1820-MEC-20000-500-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 64 Dimensional Drawing Oldham coupling adaptable to the detection element that will be mounted (see options) 100 179 190 180 50 +0,05 +0,02 154,50 10 110 180 200 282,50 180 Modular base plate 30 20 38 80 60 100 10 20 170 218,50 174,50 11 10 9 17,50 48,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 65 CDS1830 potentiometric output – Measurement range 0 up to 30 000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 30 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 2 m/s2 (before cable deformation) ≈ 15 kg -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 30 000 Min. pull-out force Max. pull-out force ≈ 15,00 N ≈ 30,00 N Ordering reference: CDS1830 OP Model CDS1830 Measurement range 30000 = 0 up to 30 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1830-30000-R01K-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 66 126 179 190 115 180 Dimensional Drawing 148 180 10 160 200 354 C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) K connection (PVC cable - 4 wires) 10 35 20 183 180 30 21,50 90 50 20 9 170 Modular base plate 100 218,50 11 11,50 16,50 20 28,50 48,50 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 67 CD1830 analog output – Measurement range 0 up to 30 000 mm Specifications: Measurement range Output signal 0 up to 30 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 8 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 2 m/s2 (before cable deformation) ≈ 15 kg -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 30 000 Min. pull-out force Max. pull-out force ≈ 15,00 N ≈ 30,00 N Ordering reference: CDS1830 OP Model CDS1830 Measurement range 30000 = 0 up to 30 000 mm (Other ranges available on-demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 8 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1830-30000-U010-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 68 126 179 190 115 180 Dimensional Drawing 148 180 10 160 200 354 C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) 180 10 35 20 183 K connection (PVC cable - 4 wires) 30 21,50 90 50 20 9 11,50 16,50 20 28,50 48,50 Modular base plate 170 100 218,50 11 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 69 CDS1830-MEC mechanical devices - Measurement range 0 up to 30 000 mm Specifications: Measurement range Circumference drum Sensing device Material 0 up to 30 000 mm 500 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 2 m/s2 (before cable deformation) ≈ 15kg -20° to +80°C -30° to +80°C Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 30 000 Min. pull-out force ≈ 15,00 N Max. pull-out force ≈ 30,00 N Ordering reference: CDS1830 MEC OP Model CDS1830-MEC Measurement range 30 000 = 0 up to 30 000 mm (Other ranges available on demand) Drum circumference 500 = 500 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR BT CP M6 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CDS1830-MEC-30000-500-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 70 Dimensional Drawing +0,05 Oldham coupling adaptable to the detection element that will be mounted (see options) 100 179 190 180 50 +0,02 148 10 160 180 200 319 180 10 Modular base plate 20 30 170 35 218,50 183 11 21,50 50 90 100 20 9 28,50 48,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 71 CDS1840 potentiometric output – Measurement range 0 up to 40 000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 40 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 1 m/s2 (before cable deformation) ≈ 20 kg -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 40 000 Min. pull-out force Max. pull-out force ≈ 15,00 N ≈ 30,00 N Ordering reference: CDS1840 OP Model CDS1840 Measurement range 40000 = 0 up to 40 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1840-40000-R01K-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 72 126 179 190 115 180 Dimensional Drawing 180 180 200 10 180 427 C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) 180 10 20 55 235 K connection (PVC cable - 4 wires) 30 21,50 90 50 20 9 11,50 16,50 20 28,50 48,37 Modular base plate 170 100 218,50 11 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 73 CD1840 analog output – Measurement range 0 up to 40 000 mm Specifications: Measurement range Output signal 0 up to 40 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 1 m/s2 (before cable deformation) ≈ 20 kg -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 40 000 Min. pull-out force Max. pull-out force ≈ 15,00 N ≈ 30,00 N Ordering reference: CDS1840 OP Model CDS1840 Measurement range 40000 = 0 up to 40 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1840-40000-U010-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 74 126 179 190 115 180 Dimensional Drawing 180 180 200 10 180 427 C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin) 180 10 20 55 235 K connection (PVC cable - 4 wires) 30 21,50 90 50 20 9 11,50 16,50 20 28,50 48,50 Modular base plate 170 100 218,50 11 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 75 CDS1840-MEC mechanical devices - Measurement range 0 up to 40 000 mm Specifications: Measurement range Circumference drum Sensing device Material 0 up to 40 000 mm 500 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 1 m/s2 (before cable deformation) ≈ 20kg -20° to +80°C -30° to +80°C Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 40 000 Min. pull-out force ≈ 15,00 N Max. pull-out force ≈ 30,00 N Ordering reference: CDS1840 MEC OP Model CDS1840-MEC Measurement range 40 000 = 0 up to 40 000 mm (Other ranges available on demand) Drum circumference 500 = 500 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR BT CP M6 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CDS1840-MEC-40000-500-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 76 Dimensional Drawing Oldham coupling adaptable to the detection element that will be mounted (see options) 100 179 190 180 50 +0,05 +0,02 180 10 180 180 200 392 180 Modular base plate 100 55 170 218,50 235 11 10 20 30 21,50 90 50 20 9 28,50 48,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 77 CDS1850 potentiometric output – Measurement range 0 up to 50 000 mm Specifications: Measurement range Output signal Resolution Material 0 up to 50 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 1 m/s2 (before cable deformation) ≈ 23 kg -20° to +80°C -30° to +80°C Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 50 000 Min. pull-out force Max. pull-out force ≈ 15,00 N ≈ 30,00 N Ordering reference: CDS1850 OP Model CDS1850 Measurement range 50000 = 0 up to 50 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1850-50000-R01K-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 78 126 179 190 180 120 Dimensional Drawing 180 200 10 200 180 467 C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin) 180 10 75 255 K connection (PVC cable - 4 wires) 20 21,50 50 90 20 30 9 20 28,50 11,50 16,50 48,50 Modular base plate 170 100 218,50 11 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 79 CD1850 analog output – Measurement range 0 up to 50 000 mm Specifications: Measurement range Output signal 0 up to 50 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 1 m/s2 (before cable deformation) ≈ 23 kg -20° to +80°C -30° to +80°C Resolution Material Cable diameter Detection element Connection Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 50 000 Min. pull-out force Max. pull-out force ≈ 15,00 N ≈ 30,00 N Ordering reference: CDS1850 OP Model CDS1850 Measurement range 50000 = 0 up to 50 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator) Linearity L15 L10 = +/- 0.15% f.s. = +/- 0.10% f.s. (optional) Connection C L4 K = Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BR BT CP IP67 M6 TEV = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) Reference example: CDS1850-50000-U010-L15-K02-OP-AC-M6 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 80 126 179 190 180 120 Dimensional Drawing 180 200 10 200 180 467 K connection (PVC cable - 4 wires) C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin) 10 75 255 180 20 21,50 50 90 20 30 9 11,50 16,50 20 28,50 48,50 Modular base plate 170 100 218,50 11 26 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 81 CDS1850-MEC mechanical devices - Measurement range 0 up to 50 000 mm Specifications: Measurement range Circumference drum Sensing device Material 0 up to 50 000 mm 500 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 1 m/s2 (before cable deformation) ≈ 23kg -20° to +80°C -30° to +80°C Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature Cable forces: Measurement range in mm 50 000 Min. pull-out force ≈ 15,00 N Max. pull-out force ≈ 30,00 N Ordering reference: CDS1850 MEC OP Model CDS1850-MEC Measurement range 50 000 = 0 up to 50 000 mm (Other ranges available on demand) Drum circumference 500 = 500 mm/turn Linearity L05 L01 = +/- 0.05% f.s. = +/- 0.01% f.s. (optional) OP options 06 10 12 AC BR BT CP M6 TEV = Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details) If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us. Reference example: CDS1850-MEC-50000-500-L05-OP-10-AC We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 82 Dimensional Drawing Oldham coupling adaptable to the detection element that will be mounted (see options) 200 10 100 179 190 180 50 +0,05 +0,02 180 180 200 432 180 10 Modular base plate 75 20 30 21,50 50 20 90 100 218,50 170 255 11 9 28,50 48,50 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 83 AS40 potentiometric output – Measurement range from 90 to 3600° Specifications: Measurement range Output signal Resolution Material 90 to 3600° 1kΩ Potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 303 10mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,25% fs (other values on demand) ≤ 300m.s-2 (11 ms) ≤ 100m.s-2 (10 … 500 Hz) IP65 (other on demand) ≈ 200 g -10° to +70°C -20° to +100°C Axis diameter Detection element Connection Linearity Shock resistance Vibration resistance Protection class Weight Operating temperature Storage temperature Ordering reference: AS40 OP Model AS40 Measurement range 0090 = 90° 0180 = 180° 0340 = 340° 1800 = 1800° 3600 = 3600° (other values on demand) Output signal R01K = 1kΩ output (Other values on demand) Output sense H A = CW = CCW Linearity L50 L25 L15 = +/- 0.50% FS (standard for ranges up to 340°) = +/- 0.25% FS (standard for ranges superior than 340°) (optional for ranges up to 340°) = +/- 0.15% FS (optional for ranges superior than 340°) Connection C L4 K = Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options IP67 = Protection class IP67 Reference example: AS40-3600-R01K-H-L25-K02-OP-IP67 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 84 Dimensional Drawing C connection (Connector M16 - DIN 3 pin ) 2 40 3 3 x M3 5 at 120° 48 17 57,50 L4 connection (connector M12 - 4 pin) 17,50 K connection (PVC cable - 4 wires) 20 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 85 36 f7 32 1,50 20 f7 12,50 6 g7 3 28 AS40 Analog output – Measurement range from 90 to 3600° Specifications: Measurement range Output signal 90 to 3600° - 0…10V - 4…20mA Current loop - 4…20mA Current generator - 0…20mA Current generator Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 303 10mm Multi-turn Hybrid potentiometer Male connector M16 – 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,25% fs (other values on demand) ≤ 300m.s-2 (11 ms) ≤ 100m.s-2 (10 … 500 Hz) IP65 (other on demand) ≈ 200 g -10° to +70°C -20° to +100°C Resolution Material Axis diameter Detection element Connection Linearity Shock resistance Vibration resistance Protection class Weight Operating temperature Storage temperature Ordering reference: AS40 OP Model AS40 Measurement range 0090 = 90° 0180 = 180° 0340 = 340° 1800 = 1800° 3600 = 3600° (other values on demand) Output signal U010 I420 I420G I020G = Output 0…10V = Output 4…20mA (2-wires current loop) = Output 4…20mA (current generator) = Output 0…20mA (current Output sense H A = CW = CCW Linearity L50 L25 L15 = +/- 0.50% FS (standard for ranges up to 340°) = +/- 0.25% FS (standard for ranges superior than 340°) (optional for ranges up to 340°) = +/- 0.15% FS (optional for ranges superior than 340°) Connection C L4 K = Male connector M16 – 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options IP67 = Protection class IP67 Reference example: AS40-3600-i420-H-L25-K02-OP-IP67 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 86 Dimensional Drawing C connection (Connector M16 - DIN 8 pin ) 2 3 40 3 x M3 5 at 120° 60 17 69,50 L4 connection (connector M12 - 4 pin) 17,50 K connection (PVC cable - 4 wires) 20 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 87 36 f7 20 f7 1,50 32 12,50 6 g7 3 28 AS58 potentiometric output – Measurement range from 90 to 3600° Specifications: Measurement range Output signal Resolution Material 90 to 3600° 1kΩ Potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 303 10mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,50% fs – Range from 340° and 1080° +/- 0,25% fs – Range from 1800° and 3600° Range from 340° and 1080° (optional) +/- 0,15% fs – Range from 1800° and 3600° (optional) ≤ 500m.s-2 (6 ms) ≤ 100m.s-2 (55 … 2 000 Hz) IP54 (option IP67) ≈ 300 g -20° to +80°C -30° to +80°C Axis diameter Detection element Connection Linearity Shock resistance Vibration resistance Protection class Weight Operating temperature Storage temperature Ordering reference: CD50 OP Model CD50 Measurement range 0340 1080 1800 3600 = 0 to 340° = 0 to 1080° = 0 to 1800° = 0 to 3600° Output signal R01K = 1kΩ output (Other values on demand) Linearity L50 L25 L15 = +/- 0.50% fs (standard for range from 340° and 1080°) = +/- 0.25% fs (standard for range from 1800° and 3600°) (optional for range from 340° and 1080°) = +/- 0.15% fs (optional for range from 1800° and 3600°) Connection C L4 K = Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BT IP67 = Complete anodizing = Low temperature (down to -30°C) = Protection class IP67 Reference example: AS58-3600-R01K-H-L25-K02-OP-IP67 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 88 Dimensional Drawing C connection (Connector M16 - DIN 3 pin ) 58 2 36 31,75 10 g7 48 3 x M3 11,50 78 10 6 at 120° 19 3 x M4 6 at 120° L4 connection (connector M12 - 4 pin) 16,50 K connection (PVC cable - 4 wires) 20 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 89 AS58 Analog output – Measurement range from 90 to 3600° Specifications: Measurement range Output signal 90 to 3600° 0…10V (galvanic isolation) 4…20mA ; 2 wires technique 4…20mA ; 4 wires technique (galvanic isolation) 0…20mA ; 4 wires technique (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 303 10mm Multi-turn Hybrid potentiometer Male connector M16 –8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,50% fs – Range ≤ 340° +/- 0,25% fs – Range > 340° Range ≤ 340° (optional) +/- 0,15% fs – Range > 340° (optional)  500m.s-2 (6 ms)  100m.s-2 (55 … 2 000 Hz) IP54 (option IP67) ≈ 700 g -20° to +80°C -30° to +80°C Resolution Material Axis diameter Detection element Connection Linearity Shock resistance Vibration resistance Protection class Weight Operating temperature Storage temperature Ordering reference: AS58 OP Model AS58 Measurement range 0340 = 0 to 340° 1080 = 0 to 1080° 1800 = 0 to 1800° 3600 = 0 to 3600° (Other values on demand) Output signal U010 I420 I420G I020G = 0…10V = 4…20mA (2 wires technique) = 4…20mA (4 wires technique) = 0…20mA (4 wires technique) Linearity L50 L25 L15 = +/- 0.50% fs (standard for ranges from 340° to 1080°) = +/- 0.25% fs (standard for ranges from 1800° to 3600°) (optional for ranges from 340° to 1080°) = +/- 0.15% fs (optional for ranges from 1800° to 3600°) Connection C L4 K = Male connector M16 – DIN 8 = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long OP Options AC BT IP67 = Complete anodizing = Low temperature (down to -30°C) = Protection class IP67 Reference example: AS58-3600-U010-H-L25-K02-OP-IP67 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 90 Dimensional Drawing C connection (Connector M16 - DIN 8 pin ) 58 2 36 31,75 10 g7 48 3 x M3 11,50 78 10 6 at 120° 19 3 x M4 6 at 120° L4 connection (connector M12 - 4 pin) 16,50 K connection (PVC cable - 4 wires) 20 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France 91 Electrical characteristics for draw-wire sensors with potentiometric output Potentiometric version 1 K : (other values on demand) Temperature drift +/-50 ppm/°C Example of wiring diagram with input stage : To ensure a good linearity, wire the potentiometer as a voltage divider and never as a rheostat. The input resistance of the operating system must be very high (greater than 10MΩ) Connection : Male connector M16 3 pin (DIN) Male connector M12 4 pin (DIN) PVC cable 4 wire R01K 1 1 Brown Input voltage + 2 2 White Input voltage GND 3 3 Green Signal + Sensor side view Sensor side view We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France 92 Electrical characteristics for draw-wire sensors with analog output Analog version 0 … 10V : Input voltage Output voltage Output current Galvanic isolation Protection 15 to +27 Vdc (52mA max) 0 to 10 Vdc 10mA max 3KV - Short circuit - Polarity reversal +/-100 ppm/°C Temperature drift Analog version 4 … 20mA : (Two-wires current loop) Input voltage Output current Protection +15 to +27 Vdc (32mA max) 4 to 20mA - Short circuit - Polarity reversal +/-100 ppm/°C Temperature drift Analog version 4…20mA or 0…20mA : (Current generator) Input voltage Output current Output current Galvanic isolation Protection +15 to +27 Vdc (75mA max) 4 to 20mA or 0 to 20mA 22 mA max. 3KV - Short circuit - Polarity reversal +/-100 ppm/°C Temperature drift Connection : Male connector M16 8 pin (DIN) Male connector M12 4 pin (DIN) PVC cable 4 wire 010V I420 (current loop) I420G or I020G (current generator) 1 1 Brown Input voltage + Signal + Input voltage + 2 2 White Input voltage GND Signal - Input voltage GND 3 3 Green Signal + Signal + 4 4 Yellow Signal GND Signal GND Sensor side view Sensor side view We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France 93 Electrical characteristics for draw-wire sensors with incremental output Electronic 2G2 (100kHz) (for CD50) Electronic 5G5 (100kHz) Supply : 5Vdc  10% Cons. without load : 100mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 2,5Vdc Supply: 11 à 30Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc Electronic 9G5 (100kHz) Electronic PG5 (100kHz) (for CD50) Supply: 5 à 24Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc Supply: 5 à 30Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc Electronic 2G2 (100°C, 300kHz) Electronic PG5 (100°C, 300kHz) Supply : 5Vdc  10% Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 4Vdc Supply : 5 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-2,5Vdc Electronic RG2 (100°C, 300kHz) Electronic 5GT (70°C, 120kHz) Supply : 4,75 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 4Vdc Supply : 11 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 1,5Vdc 1 min (Is=20mA) : Voh = Vcc-2,5Vdc Connection: Male connector M23 12 Pin - CW Male connector M23 12 Pin - CCW Male connector M16 8 pin (DIN) Male connector M16 5 pin (DIN) PVC cable 8 wire 1 10 + 11 1 1 White 2 2 + 12 2 2 Brown 3 8 3 3 Green Grey A 4 5 4 4 Yellow Brown B 5 3 5 5 Grey Red 0 6 1 6 / Pink Pink A/ 7 6 7 / Blue Green B/ 8 4 8 / Red Black 0/ PUR cable 12 wire White + White/Green Brown + Brown/Green Standard connection Supply Supply + PUR 12-LeiterKabel Sensor side view Sensor side view Sensor side view Sensor side view We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France 94 Options for draw-wire sensors, CD Series Cable attachment with a lug : Cable attachment with a clip : Standard OP-EM The attachment lug is fixed with a M6 screw or a clevis. This fastening system allows a rotation about its axis. The clip is fixed with a M4 screw or a clevis. Available for : CD50, CD60, CD80, CD115, CD150 Available for : CD50, CD60, CD80 Cable attachment fitted with a M4 threaded rod: Cable attachment with a clevis : OP-M4 OP-CP The rod attachment uses a threaded rod with 2 nuts (provided). The required thickness of the plate does not exceed 5 mm. The attachment of the clevis is done using a pin (provided). Available for : CD50, CD60, CD80, CD115, CD150 Caution Never screw the threaded rod into a fixed nut, a twist of the measurement cable would damage it. Available for : CD50, CD60, CD80, CD115, CD150 Cable dust wiper Cable cleaning brush: OP-RAC OP-BR The dust wiper cleans the cable in dusty or humid environments. The cleaning brush wipes the cable in dusty or humid environments. Available for : CD50 Available for : CD60, CD80, CD115, CD150 Water evacuation holes: OP-TEV The holes allow the natural flow of fluids out of the sensor in order to avoid their accumulation in the system. Available for : CD50, CD60, CD80, CD115, CD150 We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France 95 Options for draw-wire sensors, CDS Series Cable attachment with a lug : Cable attachment fitted with a M6 threaded rod: Standard OP-M6 Measuring cable attachment with a lug. The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. The rod attachment uses a threaded rod with 2 nuts (provided). The required thickness of the plate does not exceed 8mm. The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850 Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850 Cable cleaning brush: Cable attachment with a clevis : OP-BR OP-CP The cleaning brush wipes the cable in dusty or humid environments. The attachment of the clevis is done using a pin (provided). The attachment mounted on ball bearings allows a free rotation relative to the measurement cable. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850 Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850 Water evacuation holes: OP-TEV The holes allow the natural flow of fluids out of the sensor in order to avoid their accumulation in the system. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850 Please specify the implantation angle of the drain holes on the drawing below. (All value between 0 and 360°) We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France 96 Adapter flanges Adaptation for an encoder of diameter 58mm, and shaft diameter 6mm OP-06: Adaptation flange + Ø6 Oldham coupling OP-06A: Ø6 Oldham coupling without adaptation flange Adaptation for an encoder of diameter 58mm, and shaft diameter 10mm OP-10: Adaptation flange + Ø10 Oldham coupling Without specification, a MEC series draw-wire sensor will always be delivered with an Oldham coupling Ø10 without adaptation flange. Adaptation for an encoder of diameter 90mm, and shaft diameter 12mm OP-12: Adaptation flange + Ø12 Oldham coupling OP-12A: Ø12 Oldham coupling without adaptation flange We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France 97 Connectors Female connectors M12 4-Pins Female connector For M-connection Ø of the cable: 4 to 6 mm Ref : 5100-020 M16 Female connector - DIN For C-connection (3-Pins) Ø of the cable: 4 to 6 mm Ref: 5100-007 M16 Female connector - DIN For C-connection (8-Pins) Ø of the cable: 4 to 6 mm Ref: 5100-008 M23 CCW female connector For G6-connection (mounting on CW baseplate) Ø of the cable: 6 to 8 mm Ref: 5100-006 M23 CW female connector For G8-connection (mounting on CCW baseplate) Ø of the cable: 6 to 8 mm Ref: 5100-005 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 98 Mounting accessories Magnet clamp FAIM-5 (for CD50) Magnet clamp FAIM-25 (for CD115 and CD150) Pulley PR01 (for CD50) Pulley PR03 Cable extension Heating module for draw-wire sensors, series CDS - M4 cable plugs on both ends. Ref. : RL-XXXX-M4/M4 The heating module prevents the sensor to freeze under negative operating temperature. Don’t hesitate to contact us for any further information - Attachment heads on both ends. Ref. : RL-XXXX-CP/CP - Cable lugs on both ends. Ref. : RL-XXXX-CO/CO Other possibilities: RL-XXXX-M4/CO (M4 screw at one end – lug on the other) RL-XXXX-M4/CP (M4 screw at one end – attachment head on the other) RL-XXXX-CO/CP (Lug at one end – attachment head on the other Possibility to integrate directly the cable extension into the sensor We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 99 Accessories Clearance compensation angle Fixation angle Ref : ERJ40-002 Ref : EF058-001 Measuring wheel Oldham coupling Ref : RM200-001 Cylindrical eccentric (to mount angular sensors and optical encoders) Provided with a set of 4 eccentrics + 4 screws Ref : EXC-001 Ref : EXC-002 We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France 100