Transcript
Linear displacement sensors
Selection guide Model
CD50
CD60
Measurement range
Up to 1250 mm
Output
Page
Potentiometer (1kΩ)
4-5
Analog (0…10V / 4…20mA / 0…20mA)
6-7
Incremental
8-9
Potentiometer (1kΩ)
10 - 11
Analog (0…10V / 4…20mA / 0…20mA)
12 - 13
Incremental
14 - 15
Absolute (SSI / Profibus / CANopen / DeviceNet)
16 - 17
Potentiometer (1kΩ)
18 - 19
Analog (0…10V / 4…20mA / 0…20mA)
20 – 21
Incremental
22 – 23
Absolute (SSI / Profibus / CANopen / DeviceNet)
24 - 25
Mechanical devices (MEC)
26 - 27
Potentiometer (1kΩ)
28 - 29
Analog (0…10V / 4…20mA / 0…20mA)
30 - 31
Incremental
32 - 33
Absolute (SSI / Profibus / CANopen / DeviceNet)
34 - 35
Mechanical devices (MEC)
36 - 37
Potentiometer (1kΩ)
38 - 39
Analog (0…10V / 4…20mA / 0…20mA)
40 – 41
Incremental
42 – 43
Absolute (SSI / Profibus / CANopen / DeviceNet)
44 – 45
Mechanical devices (MEC)
46 - 47
Potentiometer (1kΩ)
48 - 49
Analog (0…10V / 4…20mA / 0…20mA)
50 - 51
Potentiometer (1kΩ)
52 - 53
Analog (0…10V / 4…20mA / 0…20mA)
54 - 55
Up to 1500 mm
Up to 2000 mm
CD80 Up to 2500 mm
Up to 3000 mm
CD115 Up to 3500 mm
CD150
AS40
AS58
Up to 6000 mm
90° to 3600°
90° to 3600°
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
2
Selection guide Model
CDS1210
CDS1215
CDS1820
CDS1830
CDS1840
CDS1850
Output connections Options Accessories
Measurement range
Up to 10 000 mm
Up to 15 000 mm
Up to 20 000 mm
Up to 30 000 mm
Up to 40 000 mm
Up to 50 000 mm
Output
Page
Potentiometer (1kΩ)
56 - 57
Analog (0…10V / 4…20mA / 0…20mA)
58 – 59
Mechanical devices (MEC)
60 – 61
Potentiometer (1kΩ)
62 – 63
Analog (0…10V / 4…20mA / 0…20mA)
64 – 65
Mechanical devices (MEC)
66 – 67
Potentiometer (1kΩ)
68 - 69
Analog (0…10V / 4…20mA / 0…20mA)
70 – 71
Mechanical devices (MEC)
72 -73
Potentiometer (1kΩ)
74 - 75
Analog (0…10V / 4…20mA / 0…20mA)
76 - 77
Mechanical devices (MEC)
78 - 79
Potentiometer (1kΩ)
80 - 81
Analog (0…10V / 4…20mA / 0…20mA)
82 - 83
Mechanical devices (MEC)
84 - 85
Potentiometer (1kΩ)
86 - 87
Analog (0…10V / 4…20mA / 0…20mA)
88 - 89
Mechanical devices (MEC)
90 - 91
Potentiometric version
84
Analog version
85
Incremental version
86
For draw-wire sensors, CD series
87
For draw-wire sensors, CDS series
88
Adapter flanges for draw-wire sensors, MEC type
89
Connectors
90
Mounting accessories
91
Accessories for optical encoders and angular sensors
92
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
3
CD50 potentiometric output – Measurement range up to 1250 mm Specifications: Measurement range Output signal Resolution Material
0 up to 1250 mm 1kΩ Potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,51 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,25% f.s. – stroke ≤500mm +/- 0,15% f.s. – stroke >500mm +/- 0,10% f.s. – stroke >500mm (option) IP54 (option IP67) 10 M/S 40 M/S2 (before cable deformation) ≈ 700 g -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity
Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 50 100 250 500 750 1000 1200 1250
Min. pull-out force
Max. pull-out force
≈ 6,40 N ≈ 6,30 N ≈ 6,00 N ≈ 5,50 N ≈ 5,00 N ≈ 4,50 N ≈ 4,00 N ≈ 4,00 N
≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N
Ordering reference:
CD50
OP
Model CD50 Measurement range 0050 = 0 up to 50 mm 0100 = 0 up to 100 mm 0250 = 0 up to 250 mm 0500 = 0 up to 500 mm 0750 = 0 up to 750 mm 1000 = 0 up to 1000 mm 1200 = 0 up to 1200 mm 1250 = 0 up to 1250 mm (Other range available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L25 L15 L10
= +/- 0.25% f.s. (standard for measuring range from 0 to 500mm) = +/- 0.15% f.s. (standard for measuring range greater than 500 mm) (option for measuring range from 0 to 500mm) = +/- 0.10% f.s. (option for measuring range greater than 500 mm)
Connection C L4 K
= Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BT CP EM EN IP67 M4 RAC TEV
= Complete anodizing = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Cable dust wiper = Water evacuation holes
Reference example: CD50-0750-R01R-L15-K02-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
4
Dimensional drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
5
CD50 analog output – Measurement range 0 up to 1250 mm Specifications: Measurement range Output signal
0 up to 1250 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,51 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,25% f.s. – stroke ≤500mm +/- 0,15% f.s. – stroke >500mm +/- 0,10% f.s. – stroke >500mm (option) IP54 (option IP67) 10 M/S 40 M/S2 (before cable deformation) ≈ 700 g -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity
Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 50 100 250 500 750 1000 1200 1250
Min. pull-out force
Max. pull-out force
≈ 6,40 N ≈ 6,30 N ≈ 6,00 N ≈ 5,50 N ≈ 5,00 N ≈ 4,50 N ≈ 4,00 N ≈ 4,00 N
≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N ≈ 6,50 N
Ordering reference: CD50
OP
Model CD50 Measurement range 0050 = 0 up to 50 mm 0100 = 0 up to 100 mm 0250 = 0 up to 250 mm 0500 = 0 up to 500 mm 0750 = 0 up to 750 mm 1000 = 0 up to 1000 mm 1200 = 0 up to 1200 mm 1250 = 0 up to 1250 mm (Other range available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L25 L15 L10
= +/- 0.25% f.s. (standard for measuring range from 0 up to 500mm) = +/- 0.15% f.s. (standard for measuring range greater than 500 mm) (option for measuring range from 0 up to 500mm) = +/- 0.10% f.s. (option for measuring range greater than 500 mm)
Connection C L4 K
= Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BT CP EM EN IP67 M4 RAC TEV
= Complete anodizing = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Cable dust wiper = Water evacuation holes
Reference example: CD50-0750-U010-L15-K02-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
6
Dimensional Drawing 18
6
30,50
49
75,50
49
40
110
34,50
6,50
30
15
49
110
70
K Connection (PVC cable - 4 wires)
L4 connection (connector M12 - 4 pin)
C connection (Connector M16 - DIN 8 pin ) 5
30
60
2,50
2x
12,50
17,50
20
14,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
7
4,50
CD50 incremental output - Measurement range 0 to 1250 mm Specifications: Measurement range Sensing device Supply and output signal
0 up to 1250 mm Incremental encoder 2G2 (5Vdc – Driver 5Vdc RS422) 5G5 (11 to 30Vdc – Push-pull) 9G5 (5 to 24Vdc – Push-pull) PG5 (5 to 30Vdc – Push-pull) 1 – 5 – 10 – 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,51 mm Male connector M16 – DIN 8 pin Male connector M16 – DIN 5 pin PVC cable – 8 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 10 M/S 40 M/S2 (before cable deformation) ≈ 700 g -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 1250
Min. pull-out force ≈ 4,00 N
Max. pull-out force ≈ 6,50 N
Ordering reference: CD50
OP
Model CD50 Measurement range 1250 = 0 à 1250 mm (Or other ranges between 0 and 1250 mm) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other range available on demand) Supply and output stage 2G2 5G5 9G5 PG5
= 5Vdc – Driver 5Vdc RS422 = 11 to 30Vdc – Push-pull = 5 to 24Vdc – Push-pull = 5 to 30Vdc – Push-pull
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection GDA G2A G3R G3A
= Male connector M16 – DIN 8 pin = Male connector M16 – DIN 5 pin = PVC cable - 8 wires - radial + ex: 020 for cable 2 meters long = PVC cable - 8 wires - axial + ex: 020 for cable 2 meters long
OP options AC BT CP EM EN M4 RAC TEV
= Complete anodizing = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Fixing of the measuring cable with a M4 threaded rod = Cable dust wiper = Water evacuation holes
Reference example: CD50-1250-05-PG5-L05-GDA-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
8
Dimensional drawing
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
9
CD60 potentiometric output – Measurement range 0 up to 1500 mm Specifications: Measurement range Output signal Resolution Material
0 up to 1500 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 20 m/s2 (before cable deformation) ≈ 1000 g -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 1500
Min. pull-out force
Max. pull-out force
≈ 9,00 N
≈ 12,00 N
Ordering reference:
CD60
OP
Model CD60 Measurement range 1500 = 0 up to 1500 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP EM EN IP67 M4 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD60-1500-R01K-L15-K02-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
10
6,50
18
59 8
97,50
59
58
132
34,50
Dimensional Drawing
60
59
19
90
161
C connection (Connector M16 - DIN 3 pin ) 76 7
L4 connection (connector M12 - 4 pin)
2
42 4,75
23,75
K connection (PVC cable - 4 wires)
4x
11,50
16,50
20
15,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
11
6,50
CD60 analog output – Measurement range 0 up to 1500 mm Specifications: Measurement range Output signal
0 up to 1500 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 20 m/s2 (before cable deformation) ≈ 1000 g -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 1500
Min. pull-out force
Max. pull-out force
≈ 9,00 N
≈ 12,00 N
Ordering reference: CD60
OP
Model CD60 Measurement range 1500 = 0 up to 1500 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP EM EN IP67 M4 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD60-1500-U010-L15-K02-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
12
6,50
18
59 8
97,50
59
58
132
34,50
Dimensional Drawing
60
59
19
90
161
C connection (Connector M16 - DIN 8 pin )
L4 connection (connector M12 - 4 pin)
76
7
2
42 4,75
23,75
K connection (PVC cable - 4 wires)
4x
11,50
16,50
20
15,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
13
6,50
CD60 incremental output - Measurement range 0 up to 1500 mm Specifications: Measurement range Sensing device Supply and output stage
0 up to 1500 mm Incremental encoder 2G2 (5Vdc - Driver 5Vdc RS422) PG5 (5 to 30Vdc - Push-pull 5-30Vdc) RG2 (4.75 to 30Vdc - Driver 5Vdc RS422) 5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc) 1 - 5 - 10 - 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW PUR cable – 12 wires PVC cable – 8 wires +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 Cable forces: 10 M/S 20 M/S2 (before cable deformation) Measurement ≈ 1000 g range in mm -20° to +85°C 1500 -40° to +85°C
Resolution Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Min. pull-out force ≈ 9,00 N
Max. pull-out force ≈ 12,00 N
Ordering reference: CD60
OP
Model CD60 Measurement range 1500 = 0 to 1500 mm (Other ranges available on demand) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other values on demand) Supply and output stage 2G2 PG5 RG2 5GT
= 5Vdc - Driver 5Vdc RS422 = 5 to 30Vdc - Push-pull 5-30Vdc = 4.75 to 30Vdc - Driver 5Vdc RS422 = 11 to 30Vdc - Transistorized push-pull 11-30Vdc
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection G6R G8R GP G3
= Male connector M23 – 12 pin CW = Male connector M23 – 12 pin CCW = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long
OP options AC BR CP EM EN M4 TEV
= Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD60-1500-05-PG5-L05-G6R-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
14
6,50
18
8
37,50
59
97,50
59
58,50
132
34,50
Dimensional Drawing
60
59
19
90
106,50 119,41
With DHM5 encoder GPR or G3R connection (PUR cable - 12 wires or PVC cable - 8 wires )
With DHM5 encoder G6R or G8R connection (Male connector M23 - 12 pin CW or CCW) 7
52,50
4x
6,50
40,75
2
40,75
42 4,75
23,75
76
15,50
54
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
15
CD60 absolute output - Measurement range 0 up to 1500 mm Specifications: Measurement range Sensing device Supply
0 up to 1500 mm Absolute encoder (PHM5 or MHM5 series) 10 - 30Vdc (MHM5) 5 - 30Vdc (PHM5) SSI Profibus CANopen DeviceNet 13 bits = 8192steps/turns 150 mm 152,4 mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW Terminal box +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 10 m/s 20 m/s² (before cable deformation) ≈ 1000 g -20° to +85°C -40° to +85°C
Interface
Resolution Distance per turns Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 1500
Min. pull-out force ≈ 9,00 N
Max. pull-out force ≈ 12,00 N
Ordering reference: CD60
OP
Model CD60 Measurement range 1500 = 0 to 1500 mm (Other ranges available on demand) Distance per turns 150 152
= 150 mm = 152,4 mm
Interface SSI/1 SSI/2 PROF CAN DEV
= MHM5 Serial transmission (SSI) = PHM5 Serial transmission (SSI) = MHM5 Profibus transmission = MHM5 CANopen transmission = MHM5 DeviceNet transmission
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection H3P 0CC PRL S6R S8R
= Terminal box (only for MHM5 Profibus and CANopen) = Terminal box (only for MHM5 DeviceNet) = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI) = 12 pins M23 connector - clockwise (only on PHM5 SSI) = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)
OP options AC BR CP EM EN M4 TEV
= Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Measuring cable coated with polyamide = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD60-1500-152-PROF-L05-H3P-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
16
6,50
18
60
20 17,50
8
20
59
59
97,50
132
34,50
Dimensional Drawing
59
19
90 175 version 0CC 160 version H3P
With MHM5 - SSI encoder PRL connection (Male connector M23 - 12 pin CCW)
76
7
4x
6,50
94,25 version 0CC 79,75 version H3P
39,75
48,75
2
136
124,50
42 4,75
23,75
With PHM5 - SSI encoder S6R or S8R connection (Male connector M23 - 12 pin CW or CCW)
With MHM5 - PROF/CANO/DNET encoder 0CC or H3P connection (Terminal box)
15,50
72,20
51
58,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
17
CD80 potentiometric output – Measurement range 0 up to 2000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 2000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 8 m/s2 (before cable deformation) ≈ 1500 g -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 2000
Min. pull-out force
Max. pull-out force
≈ 8,00 N
≈ 11,00 N
Ordering reference:
CD80
OP
Model CD80 Measurement range 2000 = 0 up to 2000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP EM IP67 M4 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD80-2000-R01K-L15-K02-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
18
18
6,50
79 8
117,50
59
58
152
34,50
Dimensional Drawing
50
29,50
79
161
120
C connection (Connector M16 - DIN 3 pin ) 100
L4 connection (connector M12 - 4 pin)
10
9
25
54,50
K connection (PVC cable - 4 wires)
2x
11,50
16,50
20
18,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
19
6,50
CD80 analog output – Measurement range 0 up to 2000 mm Specifications: Measurement range Output signal
0 up to 2000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 8 m/s2 (before cable deformation) ≈ 1500 g -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 2000
Min. pull-out force
Max. pull-out force
≈ 8,00 N
≈ 11,00 N
Ordering reference: CD80
OP
Model CD80 Measurement range 2000 = 0 up to 2000 mm (Other range available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP EM IP67 M4 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD80-2000-U010-L15-K02-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
20
18
6,50
79 8
117,50
59
58
152
34,50
Dimensional Drawing
50
29,50
79
161
120
L4 connection (connector M12 - 4 pin)
100
10
9
25
54,50
K connection (PVC cable - 4 wires)
C connection (Connector M16 - DIN 8 pin )
2x
11,50
16,50
20
18,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
21
6,50
CD80 incremental output - Measurement range 0 up to 2500 mm Specifications: Measurement range Sensing device Supply and output stage
0 up to 2500 mm Incremental encoder 2G2 (5Vdc - Driver 5Vdc RS422) PG5 (5 to 30Vdc - Push-pull 5-30Vdc) RG2 (4.75 to 30Vdc - Driver 5Vdc RS422) 5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc) 1 - 5 - 10 - 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW PUR cable - 12 wires PVC cable - 8 wires +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 Cable forces: 10 m/s 8 m/s2 (before cable deformation) Measurement ≈ 1500 g range in mm -20° to +85°C 2500 -40° to +85°C
Resolution Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Min. pull-out force ≈ 7,50 N
Max. pull-out force ≈ 11,00 N
Ordering reference: CD80
OP
Model CD80 Measurement range 2500 = 0 up to 2500 mm (Other ranges available on demand) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other values on-demand) Supply and output stage 2G2 PG5 RG2 5GT
= 5Vdc - Driver 5Vdc RS422 = 5 to 30Vdc - Push-pull 5-30Vdc = 4.75 to 30Vdc - Driver 5Vdc RS422 = 11 to 30Vdc - Transistorized push-pull 11-30Vdc
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection G6R G8R GP G3
= Male connector M23 – 12 pin CW = Male connector M23 – 12 pin CCW = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long
OP options AC BR CP EM M4 TEV
= Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD80-2500-05-PG5-L05-G6R-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
22
18
6,50
8
47,50
117,50
79
59
152
34,50
Dimensional Drawing
50
29,50
79
106,50
120
119,40
With DHM5 encoder G6R or G8R connection (Male connector M23 - 12 pin CW or CCW) 100 10
54,50
With DHM5 encoder GPR or G3R connection (PUR cable - 12 wires or PVC cable - 8 wires )
52
51
9
25
2x
18,50
52,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
54
23
6,50
CD80 absolute output - Measurement range 0 up to 2500 mm Specifications: Measurement range Sensing device Supply
0 up to 2500 mm Absolute encoder (PHM5 or MHM5 series) 10 - 30Vdc (MHM5) 5 - 30Vdc (PHM5) SSI Profibus CANopen DeviceNet 13 bits = 8192steps/turns 200 mm 204,8 mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW Terminal box +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 10 m/s 8 m/s2 (before cable deformation) ≈ 1500 g -20° to +85°C -40° to +85°C
Interface
Resolution Distance per turns Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 2500
Min. pull-out force ≈ 7,50 N
Max. pull-out force ≈ 11,00 N
Ordering reference: CD80
OP
Model CD80 Measurement range 2500 = 0 à 2500 mm (Other ranges available on demand) Distance per turns 200 204
= 200 mm = 204,8 mm
Interface SSI/1 SSI/2 PROF CAN DEV
= MHM5 Serial transmission (SSI) = PHM5 Serial transmission (SSI) = MHM5 Profibus transmission = MHM5 CANopen transmission = MHM5 DeviceNet transmission
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection H3P 0CC PRL S6R S8R
= Terminal box (only for MHM5 Profibus and CANopen) = Terminal box (only for MHM5 DeviceNet) = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI) = 12 pins M23 connector - clockwise (only on PHM5 SSI) = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)
OP options AC BR CP EM M4 TEV
= Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD80-2500-204-PROF-L05-H3P-OP-AC-EM
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
24
18
6,50
20 8
27,50
20
79
59
117,50
152
34,50
Dimensional Drawing
50
29,50
79 120
175 version 0CC 160 version H3P
With MHM5 - SSI encoder PRL connection (Male connector M23 - 12 pin CCW)
100
10
54,50
With PHM5 - SSI encoder S6R or S8R connection (Male connector M23 - 12 pin CW or CCW)
With MHM5 - PROF/CANO/DNET encoder H3P or 0CC connection (Terminal box)
105,50 version 0CC 91 version H3P
60
51
136
9
124,50
25
2x
18,50
72,20
51
58,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
25
6,50
CD80-MEC mechanical devices - Measurement range 0 up to 2500 mm Specifications: Measurement range Circumference drum
0 up to 2500 mm 200 mm/turn 204,8 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 8 m/s2 (before cable deformation) ≈ 1500 g -20° to +80°C -30° to +80°C
Sensing device Material Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 2500
Min. pull-out force ≈ 7,50 N
Max. pull-out force ≈ 11,00 N
Ordering reference:
CD80
MEC
OP
Model CD80-MEC Measurement range 2500 = 0 up to 2500 mm (Other range available on demand) Drum circumference 200 204
= 200 mm/turn = 204,8 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR CP EM M4 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a clip = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CD80-MEC-2500-200-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
26
Dimensional Drawing
6,50
34,50
18
8
47,50
117,50
79
59
152
Oldham coupling adaptable to the detection element that will be mounted (see options)
50
29,50
+0,05
50 +0,02
127,40
79 120
54,50
100
10
9
25
2x
18,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
27
6,50
CD115 potentiometric output – Measurement range 0 up to 3000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 3000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10m/s 7 m/s2 (before cable deformation) ≈ 2000 g -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 3000
Min. pull-out force
Max. pull-out force
≈ 13,50 N
≈ 18,00 N
Ordering reference:
CD115
OP
Model CD115 Measurement range 3000 = 0 up to 3000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M4 TEV BR
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes = Cleaning brush for the cable
Reference example: CD115-3000-R01K-L15-K02-OP-AC-M4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
28
Dimensional Drawing 6,50
8
65,50
153,50
115
89
58
188
34,50
18
50
31
115
162
155
K connection (PVC cable - 4 wires)
C connection (Connector M16 - DIN 3 pin )
L4 connection (connector M12 - 4 pin)
10
25
56
135
7,50
2x
11,50
16,50
20
20,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
29
6,50
CD115 analog output – Measurement range 0 up to 3000 mm Specifications: Measurement range Output signal
0 up to 3000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,61 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 M/S 7 M/S2 (before cable deformation) ≈ 2000 g -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 3000
Min. pull-out force
Max. pull-out force
≈ 13,50 N
≈ 18,00 N
Ordering reference: CD115
OP
Model CD115 Measurement range 3000 = 0 up to 3000 mm (Other range available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M4 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD115-3000-U010-L15-K02-OP-AC-M4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
30
Dimensional Drawing 6,50
8
65,50
153,50
115
89
58
188
34,50
18
50
31
115
162
155
C connection (Connector M16 - DIN 8 pin )
L4 connection (connector M12 - 4 pin)
135
10
25
56
K connection (PVC cable - 4 wires)
7,50
2x
11,50
16,50
20
20,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
31
6,50
CD115 incremental output - Measurement range 0 up to 3500 mm Specifications: Measurement range Sensing device Supply and output stage
0 up to 3500 mm Incremental encoder 2G2 (5Vdc - Driver 5Vdc RS422) PG5 (5 to 30Vdc - Push-pull 5-30Vdc) RG2 (4.75 to 30Vdc - Driver 5Vdc RS422) 5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc) 1 - 5 - 10 - 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW PUR cable – 12 wires PVC cable – 8 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 Cable forces: 10 m/s 7 m/s2 (before cable deformation) Measurement ≈ 2000 g range in mm -20° to +85°C 3500 -40° to +85°C
Resolution Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Min. pull-out force ≈ 13,00 N
Max. pull-out force ≈ 18,00 N
Ordering reference: CD115
OP
Model CD115 Measurement range 3500 = 0 up to 3500 mm (Other ranges available on demand) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other values on demand) Supply and output stage 2G2 PG5 RG2 5GT
= 5Vdc - Driver 5Vdc RS422 = 5 to 30Vdc - Push-pull 5-30Vdc = 4.75 to 30Vdc - Driver 5Vdc RS422 = 11 to 30Vdc - Transistorized push-pull 11-30Vdc
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection G6R G8R GP G3
= Male connector M23 – 12 pin CW = Male connector M23 – 12 pin CCW = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long
OP options AC BR CP M4 TEV
= Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD115-3500-05-PG5-L05-G6R-OP-AC-M4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
32
Dimensional Drawing
6,50
8
65,50
115
153,50
89
188
34,50
18
50
31
115
120,50
155
With DHM5 encoder GPR or G3R connection (PUR cable - 12 wires or PVC cable - 8 wires )
With DHM5 encoder G6R or G8R connection (Male connector M23 - 12 pin CW or CCW) 10
56
135
51,50
7,50
51,50
25
2x
20,50 52,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
54
33
6,50
CD115 absolute output - Measurement range 0 up to 3500 mm Specifications: Measurement range Sensing device Supply
0 up to 3500 mm Absolute encoder (PHM5 or MHM5 series) 10 - 30Vdc (MHM5) 5 - 30Vdc (PHM5) SSI Profibus CANopen DeviceNet 13 bits = 8192steps/turns 300 mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW Terminal box +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 10 M/S 7 M/S2 (before cable deformation) ≈ 2000 g -20° to +85°C -40° to +85°C
Interface
Resolution Distance per turns Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 3500
Min. pull-out force ≈ 13,00 N
Max. pull-out force ≈ 18,00 N
Ordering reference:
CD115
OP
Model CD115 Measurement range 3500 = 0 à 3500 mm (Other range available on demand) Distance per turns 300
= 300 mm
Interface SSI/1 SSI/2 PROF CAN DEV
= MHM5 Serial transmission (SSI) = PHM5 Serial transmission (SSI) = MHM5 Profibus transmission = MHM5 CANopen transmission = MHM5 DeviceNet transmission
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection H3P 0CC PRL S6R S8R
= Terminal box (only for MHM5 Profibus and CANopen) = Terminal box (only for MHM5 DeviceNet) = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI) = 12 pins M23 connector - clockwise (only on PHM5 SSI) = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)
OP options AC BR CP M4 TEV
= Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD115-3500-300-PROF-L05-H3P-OP-AC-M4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
34
Dimensional Drawing 6,50
20 20
8
45,50
153,50
115
60
89
188
34,50
18
50
31
115 155
176 version 0CC 161 version H3P
With MHM5 - SSI encoder PRL connection (Male connector M23 - 12 pin CCW)
135
10
2x
105 version 0CC 90,50 version H3P
7,50
51
59,50
137
125,50
25
56
With PHM5 - SSI encoder S6R or S8R connection (Male connector M23 - 12 pin CW or CCW)
With MHM5 - PROF/CANO/DNET encoder 0CC or H3P connection (Terminal box)
20,50 72,20 51
58,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
35
6,50
CD115-MEC mechanical devices - Measurement range 0 up to 3500 mm Specifications: Measurement range Circumference drum Sensing device Material
0 up to 3500 mm 300 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 7 m/s2 (before cable deformation) ≈ 2000 g -20° to +80°C -30° to +80°C
Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 3500
Min. pull-out force ≈ 13,00 N
Max. pull-out force ≈ 18,00 N
Ordering reference:
CD115
MEC
OP
Model CD115-MEC Measurement range 3500 = 0 up to 3500 mm (Other ranges available on demand) Drum circumference 300
= 300 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR CP M4 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CD115-MEC-3500-300-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
36
Dimensional Drawing
6,50
Oldham coupling adaptable to the detection element that will be mounted (see options)
8
65,50
115
188 89
153,50
34,50
18
50
+0,05
31
50 +0,02
128,40
115 155
135
10
7,50
25
56
2x
20,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
37
6,50
CD150 potentiometric output – Measurement range 0 up to 6000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 6000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 5 m/s2 (before cable deformation) ≈ 3000 g -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 4000 6000
Min. pull-out force
Max. pull-out force
≈ 11,00 N ≈ 10,00 N
≈ 13,50 N ≈ 13,50 N
Ordering reference:
CD150
OP
Model CD150 Measurement range 4000 = 0 up to 4000 mm 6000 = 0 up to 6000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M4 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD150-4000-R01K-L15-K02-OP-AC-M4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
38
Dimensional Drawing 18
6,50
8
82
148
221 89
58
186,50
34,50
Measurement range up to 4000 mm
60
30,25
148
171,50
186 C connection (Connector M16 - DIN 3 pin ) 170
L4 connection (connector M12 - 4 pin)
8
12,25
44
38,25 8
K connection (PVC cable - 4 wires)
4x
6,50
16,50
11,50
20
20,25
Measuring range greater than 4000 mm up to 6000 mm
6,50
8
108
148
186,50
89
120
221
34,50
18
60
30,25
148
138
186 C connection (Connector M16 - DIN 3 pin )
L4 connection (connector M12 - 4 pin)
170
8
20
12,25
44
38,25 8
K connection (PVC cable - 4 wires)
4x
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
11,50
16,50
20,25
39
6,50
CD150 analog output – Measurement range 0 up to 6000 mm Specifications: Measurement range Output signal
0 up to 6000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP54 (option IP67) 10 m/s 5 m/s2 (before cable deformation) ≈ 3000 g -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 4000 6000
Min. pull-out force
Max. pull-out force
≈ 11,00 N ≈ 10,00 N
≈ 13,50 N ≈ 13,50 N
Ordering reference: CD150
OP
Model CD150 Measurement range 4000 = 0 up to 4000 mm 6000 = 0 up to 6000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M4 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD150-4000-U010-L15-K02-OP-AC-M4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
40
18
6,50
8
82
148
89
58
221
Measurement range up to 4000 mm
186,50
34,50
Dimensional Drawing
60
30,25
148
171,50
186
C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin)
170
8
12,25
44
38,25 8
K connection (PVC cable - 4 wires)
4x
6,50
11,50
16,50
20
20,25
Measuring range greater than 4000 mm up to 6000 mm
6,50
8
108
148
221 89
120
186,50
34,50
18
60
30,25
148
138
186
C connection (Connector M16 - DIN 8 pin )
L4 connection (connector M12 - 4 pin)
170
8
20
12,25
44
38,25 8
K connection (PVC cable - 4 wires)
4x
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
11,50
16,50
20,25
41
6,50
CD150 incremental output - Measurement range 0 up to 6000 mm Specifications: Measurement range Sensing device Supply and output stage
0 up to 6000 mm Incremental encoder 2G2 (5Vdc - Driver 5Vdc RS422) PG5 (5 to 30Vdc - Push-pull 5-30Vdc) RG2 (4.75 to 30Vdc - Driver 5Vdc RS422) 5GT (11 to 30Vdc - Transistorized push-pull 11-30Vdc) 1 - 5 - 10 - 20 or 25 pulses per mm Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW 12-wires PUR cable 8-wires PVC cable +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 Cable forces: 10 M/S 5 M/S2 (before cable deformation) Measurement ≈ 3000 g range in mm -20° to +85°C 6000 -40° to +85°C
Resolution Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Min. pull-out force ≈ 10,00 N
Max. pull-out force ≈ 13,50 N
Ordering reference: CD150
OP
Model CD150 Measurement range 6000 = 0 up to 6000 mm (Other ranges available on demand) Resolution 01 = 1 pulses per mm 05 = 5 pulses per mm 10 = 10 pulses per mm 20 = 20 pulses per mm 25 = 25 pulses per mm (Other values on demand) Supply and output stage 2G2 PG5 RG2 5GT
= 5Vdc - Driver 5Vdc RS422 = 5 to 30Vdc - Push-pull 5-30Vdc = 4.75 to 30Vdc - Driver 5Vdc RS422 = 11 to 30Vdc - Transistorized push-pull 11-30Vdc
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection G6R G8R GP G3
= Male connector M23 – 12 pin CW = Male connector M23 – 12 pin CCW = PUR cable - 12 wires + ex: R020 for cable radial 2 meters long = PVC cable - 8 wires + ex: R020 for cable radial 2 meters long
OP options AC BR BT CP M4 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD150-6000-05-PG5-L05-G6R-OP-AC-M4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
42
18
6,50
8
82
148
221 89
58,50
186,50
34,50
Dimensional Drawing
60
30,25
148
130
186
With DHM5 encoder GPR or G3R connection (PUR cable - 12 wires or PVC cable - 8 wires )
With DHM5 encoder G6R or G8R connection (Male connector M23 - 12 pin CW or CCW)
8
8
4x
34,75
12,25
34,75
44
38,25
170
20,25 52,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
54
43
6,50
CD150 absolute output - Measurement range 0 up to 6000 mm Specifications: Measurement range Sensing device Supply
0 up to 6000 mm Absolute encoder (PHM5 or MHM5 series) 10 - 30Vdc (MHM5) 5 - 30Vdc (PHM5) SSI Profibus CANopen DeviceNet 13 bits = 8192steps/turns 409,6 mm Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm Male connector M23 – 12 pin CW Male connector M23 – 12 pin CCW Terminal box +/- 0,05% f.s. +/- 0,01% f.s. (optional) IP64 10 M/S 5 M/S2 (before cable deformation) ≈ 3000 g -20° to +85°C -40° to +85°C
Interface
Resolution Distance per turns Material Cable diameter Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 6000
Min. pull-out force ≈ 10,00 N
Max. pull-out force ≈ 13,50 N
Ordering reference:
CD150
OP
Model CD150 Measurement range 6000 = 0 à 6000 mm (Other ranges available on demand) Distance per turns 409
= 409,6 mm
Interface SSI/1 SSI/2 PROF CAN DEV
= MHM5 Serial transmission (SSI) = PHM5 Serial transmission (SSI) = MHM5 Profibus transmission = MHM5 CANopen transmission = MHM5 DeviceNet transmission
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
Connection H3P 0CC PRL S6R S8R
= Terminal box (only for MHM5 Profibus and CANopen) = Terminal box (only for MHM5 DeviceNet) = 12 pins M23 connector - counter-clockwise (only on MHM5 SSI) = 12 pins M23 connector - clockwise (only on PHM5 SSI) = 12 pins M23 connector - counter-clockwise (only on PHM5 SSI)
OP options AC BR CP M4 TEV
= Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
Reference example: CD150-6000-409-PROF-L05-H3P-OP-AC-M4
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
44
Dimensional Drawing 6,50
20 20
8
62
186,50
148
60
89
221
34,50
18
30,25
148
185,50 version 0CC 170,50 version H3P
With MHM5 - PROF/CANO/DNET encoder 0CC or H3P connection (Terminal box) 170 8
4x
44 12,25
42,75
146,50
33,50
135
8
With MHM5 - SSI encoder PRL connection (Male connector M23 - 12 pin CCW)
38,25
With PHM5 - SSI encoder S6R or S8R connection (Male connector M23 - 12 pin CW or CCW)
186
88,25 version 0CC 73,75 version H3P
60
20,25 72,20 51
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
45
6,50
CD150-MEC mechanical devices - Measurement range 0 up to 6000 mm Specifications: Measurement range Circumference drum Sensing device Material
0 up to 6000 mm 409,6 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,60 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 5 m/s2 (before cable deformation) ≈ 3000 g -20° to +80°C -30° to +80°C
Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 6000
Min. pull-out force ≈ 10,00 N
Max. pull-out force ≈ 13,50 N
Ordering reference:
CD150
MEC
OP
Model CD150-MEC Measurement range 6000 = 0 up to 6000 mm (Other ranges available on demand) Drum circumference 409
= 409,6 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR CP M4 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M4 threaded rod = Water evacuation holes
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CD150-MEC-6000-409-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
46
Dimensional Drawing
6,50
8
82
186,50
Oldham coupling adaptable to the detection element that will be mounted (see options)
148
89
78
221
34,50
18
60
+0,05
30,25
50 +0,02
137,90
148 186
8
8
44
38,25
170
12,25
4x
20,25
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
47
6,50
CDS1210 potentiometric output – Measurement range 0 up to 10 000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 10 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 5 m/s2 (before cable deformation) ≈ 6 kg -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 10 000
Min. pull-out force
Max. pull-out force
≈ 10,50 N
≈ 15,00 N
Ordering reference:
CDS1210
OP
Model CDS1210 Measurement range 10000 = 0 up to 10 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1210-10000-R01K-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
48
114
8
94
128
120
120
Dimensional Drawing
102
66
120
216
135
C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin)
47 115
10
84,50 18,50
K connection (PVC cable - 4 wires)
20,20
30
60 40
10
30
40,50
132
Modular base plate
68
172,50
11,50
11,50
16,50
20
9
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
49
CD1210 analog output – Measurement range 0 up to 10 000 mm Specifications: Measurement range Output signal
0 up to 10 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 8 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 M/S 5 M/S2 (before cable deformation) ≈ 6 kg -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 10 000
Min. pull-out force
Max. pull-out force
≈ 11,00 N
≈ 13,50 N
Ordering reference: CDS1210
OP
Model CDS1210 Measurement range 10000 = 0 up to 10 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 8 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1210-10000-U010-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
50
114
8
94
128
120
120
Dimensional Drawing
102
66
120 135
216
K connection (PVC cable - 4 wires)
C connection (Connector M16 - DIN 8 pin )
L4 connection (connector M12 - 4 pin)
47
84,50
10
18,50
115
20,20
30
40
60
10
30
40,50
130,50
Modular base plate
68
172,50
11,50
11,50
16,50
20
9
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
51
CDS1210-MEC mechanical devices - Measurement range 0 up to 10 000 mm Specifications: Measurement range Circumference drum Sensing device Material
0 up to 10 000 mm 300 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable – Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 5 m/s2 (before cable deformation) ≈ 6kg -20° to +80°C -30° to +80°C
Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 10 000
Min. pull-out force ≈ 10,50 N
Max. pull-out force ≈ 15,00 N
Ordering reference:
CDS1210
MEC
OP
Model CDS1210-MEC Measurement range 10000 = 0 up to 10 000 mm (Other ranges available on demand) Drum circumference 300
= 300 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR BT CP M6 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1210-MEC-10000-300-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
52
Dimensional Drawing +0,05
Oldham coupling adaptable to the detection element that will be mounted (see options)
8
68
114
128
120
50 +0,02
102
66
120
181
135
Modular base plate
47
11,50
84,50
10
18,50
115
20,20
68
30
60 40
132
10
172,50
30
9
40,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
53
CDS1215 potentiometric output – Measurement range 0 up to 15 000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 15 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 4 m/s2 (before cable deformation) ≈ 8 kg -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 15 000
Min. pull-out force
Max. pull-out force
≈ 10,50 N
≈ 15,00 N
Ordering reference:
CDS1215
OP
Model CDS1215 Measurement range 15000 = 0 up to 15 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1215-15000-R01K-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
54
114
8
94
128
120
120
Dimensional Drawing
137,50
120
128
135
311,50
C connection (Connector M16 - DIN 3 pin ) K connection (PVC cable - 4 wires)
L4 connection (connector M12 - 4 pin)
47 10
52,50 10
180,50
115
20,20
30
60 40
30
11,50
16,50
20
9
40,50
Modular base plate
132 68
172,50
11,50
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
55
CD1215 analog output – Measurement range 0 up to 15 000 mm Specifications: Measurement range Output signal
0 up to 15 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 8 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 4 m/s2 (before cable deformation) ≈ 8 kg -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 15 000
Min. pull-out force
Max. pull-out force
≈ 10,50 N
≈ 15,00 N
Ordering reference: CDS1215
OP
Model CDS1215 Measurement range 15000 = 0 up to 15 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 8 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1215-15000-U010-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
56
114
8
94
128
120
120
Dimensional Drawing
137,50
120
128
135
311,50
K connection (PVC cable - 4 wires)
C connection (Connector M16 - DIN 8 pin )
L4 connection (connector M12 - 4 pin)
47 10
52,50 10
180,50
115
20,20
30
60 40
30
11,50
16,50
20
9
40,50
Modular base plate
68
172,50
132
11,50
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
57
CDS1215-MEC mechanical devices - Measurement range 0 up to 15 000 mm Specifications: Measurement range Circumference drum Sensing device Material
0 up to 15 000 mm 300 mm/turn Adaptable with all of our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 4 m/s² (before cable deformation) ≈ 8kg -20° to +80°C -30° to +80°C
Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 15 000
Min. pull-out force ≈ 10,50 N
Max. pull-out force ≈ 15,00 N
Ordering reference:
CDS1215
MEC
OP
Model CDS1215-MEC Measurement range 15000 = 0 up to 15 000 mm (Other ranges available on demand) Drum circumference 300
= 300 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR BT CP M6 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1215-MEC-15000-300-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
58
Dimensional Drawing
+0,05
Oldham coupling adaptable to the detection element that will be mounted (see options)
8
68
114
128
120
50 +0,02
137,50
120
128
135
276,50
47 115
Modular base plate
10
52,50 10
132
172,50
180,50
11,50
20,20
30
60 40
30
9 40,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
59
CDS1820 potentiometric output – Measurement range 0 up to 20 000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 20 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 2 m/s2 (before cable deformation) ≈ 12 kg -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 20 000
Min. pull-out force
Max. pull-out force
≈ 15,00 N
≈ 30,00 N
Ordering reference:
CDS1820
OP
Model CDS1820 Measurement range 20000 = 0 up to 20 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1820-20000-R01K-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
60
126
179
190
180
120
Dimensional Drawing
154,50
180 200
10
110 317,50
C connection (Connector M16 - DIN 3 pin )
L4 connection (connector M12 - 4 pin)
180
10
20
174,50
K connection (PVC cable - 4 wires)
30
38
60
80
10
20
9
11,50
16,50
20
17,50 48,50
170 100
218,50
Modular base plate
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
61
CD1820 analog output – Measurement range 0 up to 20 000 mm Specifications: Measurement range Output signal
0 up to 20 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 8 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 2 m/s2 (before cable deformation) ≈ 12 kg -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 20 000
Min. pull-out force
Max. pull-out force
≈ 15,00 N
≈ 30,00 N
Ordering reference:
CDS1820
OP
Model CDS1820 Measurement range 20000 = 0 up to 20 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 8 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1820-20000-U010-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
62
126
179
190
180
120
Dimensional Drawing
154,50
180 200
10
110 317,50
C connection (Connector M16 - DIN 3 pin )
L4 connection (connector M12 - 4 pin)
180
10
20
174,50
K connection (PVC cable - 4 wires)
30
38
60
80
10
20
9
11,50
16,50
20
17,50 48,50
170 100
218,50
Modular base plate
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
63
CDS1820-MEC mechanical devices - Measurement range 0 up to 20 000 mm Specifications: Measurement range Circumference drum Sensing device Material
0 up to 20 000 mm 500 mm/turn Adaptable with all of our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 2 m/s2 (before cable deformation) ≈ 12kg -20° to +80°C -30° to +80°C
Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 20 000
Min. pull-out force ≈ 15,00 N
Max. pull-out force ≈ 30,00 N
Ordering reference:
CDS1820
MEC
OP
Model CDS1820-MEC Measurement range 20 000 = 0 up to 20 000 mm (Other ranges available on demand) Drum circumference 500
= 500 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR BT CP M6 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1820-MEC-20000-500-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
64
Dimensional Drawing Oldham coupling adaptable to the detection element that will be mounted (see options)
100
179
190
180
50
+0,05 +0,02
154,50
10
110
180 200
282,50
180
Modular base plate
30 20
38
80 60
100
10
20
170
218,50
174,50
11
10
9 17,50 48,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
65
CDS1830 potentiometric output – Measurement range 0 up to 30 000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 30 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 2 m/s2 (before cable deformation) ≈ 15 kg -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 30 000
Min. pull-out force
Max. pull-out force
≈ 15,00 N
≈ 30,00 N
Ordering reference:
CDS1830
OP
Model CDS1830 Measurement range 30000 = 0 up to 30 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1830-30000-R01K-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
66
126
179
190
115
180
Dimensional Drawing
148
180
10
160
200
354
C connection (Connector M16 - DIN 3 pin )
L4 connection (connector M12 - 4 pin)
K connection (PVC cable - 4 wires)
10
35 20
183
180
30
21,50
90 50
20
9
170
Modular base plate
100
218,50
11
11,50
16,50
20
28,50 48,50
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
67
CD1830 analog output – Measurement range 0 up to 30 000 mm Specifications: Measurement range Output signal
0 up to 30 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 8 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 2 m/s2 (before cable deformation) ≈ 15 kg -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 30 000
Min. pull-out force
Max. pull-out force
≈ 15,00 N
≈ 30,00 N
Ordering reference:
CDS1830
OP
Model CDS1830 Measurement range 30000 = 0 up to 30 000 mm (Other ranges available on-demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 8 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1830-30000-U010-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
68
126
179
190
115
180
Dimensional Drawing
148
180
10
160
200
354
C connection (Connector M16 - DIN 3 pin )
L4 connection (connector M12 - 4 pin)
180
10
35 20
183
K connection (PVC cable - 4 wires)
30
21,50
90 50
20
9
11,50
16,50
20
28,50 48,50
Modular base plate
170 100
218,50
11
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
69
CDS1830-MEC mechanical devices - Measurement range 0 up to 30 000 mm Specifications: Measurement range Circumference drum Sensing device Material
0 up to 30 000 mm 500 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 2 m/s2 (before cable deformation) ≈ 15kg -20° to +80°C -30° to +80°C
Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 30 000
Min. pull-out force ≈ 15,00 N
Max. pull-out force ≈ 30,00 N
Ordering reference:
CDS1830
MEC
OP
Model CDS1830-MEC Measurement range 30 000 = 0 up to 30 000 mm (Other ranges available on demand) Drum circumference 500
= 500 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR BT CP M6 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1830-MEC-30000-500-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
70
Dimensional Drawing +0,05
Oldham coupling adaptable to the detection element that will be mounted (see options)
100
179
190
180
50 +0,02
148
10
160
180 200
319
180
10
Modular base plate
20
30
170
35
218,50
183
11
21,50
50
90
100
20
9
28,50 48,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
71
CDS1840 potentiometric output – Measurement range 0 up to 40 000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 40 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 1 m/s2 (before cable deformation) ≈ 20 kg -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 40 000
Min. pull-out force
Max. pull-out force
≈ 15,00 N
≈ 30,00 N
Ordering reference:
CDS1840
OP
Model CDS1840 Measurement range 40000 = 0 up to 40 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1840-40000-R01K-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
72
126
179
190
115
180
Dimensional Drawing
180
180 200
10
180 427
C connection (Connector M16 - DIN 3 pin ) L4 connection (connector M12 - 4 pin)
180
10
20
55
235
K connection (PVC cable - 4 wires)
30
21,50
90 50
20
9
11,50
16,50
20
28,50 48,37
Modular base plate
170 100
218,50
11
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
73
CD1840 analog output – Measurement range 0 up to 40 000 mm Specifications: Measurement range Output signal
0 up to 40 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 1 m/s2 (before cable deformation) ≈ 20 kg -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 40 000
Min. pull-out force
Max. pull-out force
≈ 15,00 N
≈ 30,00 N
Ordering reference:
CDS1840
OP
Model CDS1840 Measurement range 40000 = 0 up to 40 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1840-40000-U010-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
74
126
179
190
115
180
Dimensional Drawing
180
180 200
10
180 427
C connection (Connector M16 - DIN 8 pin ) L4 connection (connector M12 - 4 pin)
180
10
20
55
235
K connection (PVC cable - 4 wires)
30
21,50
90 50
20
9
11,50
16,50
20
28,50 48,50
Modular base plate
170 100
218,50
11
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
75
CDS1840-MEC mechanical devices - Measurement range 0 up to 40 000 mm Specifications: Measurement range Circumference drum Sensing device Material
0 up to 40 000 mm 500 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 1 m/s2 (before cable deformation) ≈ 20kg -20° to +80°C -30° to +80°C
Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 40 000
Min. pull-out force ≈ 15,00 N
Max. pull-out force ≈ 30,00 N
Ordering reference:
CDS1840
MEC
OP
Model CDS1840-MEC Measurement range 40 000 = 0 up to 40 000 mm (Other ranges available on demand) Drum circumference 500
= 500 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR BT CP M6 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1840-MEC-40000-500-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
76
Dimensional Drawing Oldham coupling adaptable to the detection element that will be mounted (see options)
100
179
190
180
50
+0,05 +0,02
180
10
180
180 200
392
180
Modular base plate
100
55
170
218,50
235
11
10
20
30
21,50
90 50
20
9
28,50 48,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
77
CDS1850 potentiometric output – Measurement range 0 up to 50 000 mm Specifications: Measurement range Output signal Resolution Material
0 up to 50 000 mm 1kΩ potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 - DIN 3 pin Male connector M12 - 4 pin PVC cable - 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 1 m/s2 (before cable deformation) ≈ 23 kg -20° to +80°C -30° to +80°C
Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 50 000
Min. pull-out force
Max. pull-out force
≈ 15,00 N
≈ 30,00 N
Ordering reference:
CDS1850
OP
Model CDS1850 Measurement range 50000 = 0 up to 50 000 mm (Other ranges available on demand) Output signal R01K = 1kΩ output (Other values on demand) Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 - DIN 3 pin = Male connector M12 - 4 pin = PVC cable - 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1850-50000-R01K-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
78
126
179
190
180
120
Dimensional Drawing
180 200
10
200
180 467
C connection (Connector M16 - DIN 3 pin )
L4 connection (connector M12 - 4 pin)
180
10
75
255
K connection (PVC cable - 4 wires)
20
21,50
50
90
20
30
9
20
28,50 11,50
16,50
48,50
Modular base plate
170 100
218,50
11
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
79
CD1850 analog output – Measurement range 0 up to 50 000 mm Specifications: Measurement range Output signal
0 up to 50 000 mm 0…10V (galvanic isolation) 4…20mA current loop 4…20mA current generator (galvanic isolation) 0…20mA current generator (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,15% f.s. +/- 0,10% f.s. (optional) IP65 10 m/s 1 m/s2 (before cable deformation) ≈ 23 kg -20° to +80°C -30° to +80°C
Resolution Material Cable diameter Detection element Connection
Standard linearity Protection class Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 50 000
Min. pull-out force
Max. pull-out force
≈ 15,00 N
≈ 30,00 N
Ordering reference:
CDS1850
OP
Model CDS1850 Measurement range 50000 = 0 up to 50 000 mm (Other ranges available on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (current loop) = 4…20mA (current generator) = 0…20mA (current generator)
Linearity L15 L10
= +/- 0.15% f.s. = +/- 0.10% f.s. (optional)
Connection C L4 K
= Male connector M16 – DIN 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BR BT CP IP67 M6 TEV
= Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Protection class IP67 = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
Reference example: CDS1850-50000-U010-L15-K02-OP-AC-M6
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
80
126
179
190
180
120
Dimensional Drawing
180 200
10
200
180 467
K connection (PVC cable - 4 wires)
C connection (Connector M16 - DIN 8 pin )
L4 connection (connector M12 - 4 pin)
10
75
255
180
20
21,50
50
90
20
30
9
11,50
16,50
20
28,50 48,50
Modular base plate
170 100
218,50
11
26
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
81
CDS1850-MEC mechanical devices - Measurement range 0 up to 50 000 mm Specifications: Measurement range Circumference drum Sensing device Material
0 up to 50 000 mm 500 mm/turn Adaptable with all our incremental or absolute encoders Body and cover - aluminium (RohS) Measuring cable - Stainless steel 0,90 mm +/- 0,05% f.s. +/- 0,01% f.s. (optional) 10 m/s 1 m/s2 (before cable deformation) ≈ 23kg -20° to +80°C -30° to +80°C
Cable diameter Standard linearity Max. Velocity Max. Acceleration Weight Operating temperature Storage temperature
Cable forces: Measurement range in mm 50 000
Min. pull-out force ≈ 15,00 N
Max. pull-out force ≈ 30,00 N
Ordering reference:
CDS1850
MEC
OP
Model CDS1850-MEC Measurement range 50 000 = 0 up to 50 000 mm (Other ranges available on demand) Drum circumference 500
= 500 mm/turn
Linearity L05 L01
= +/- 0.05% f.s. = +/- 0.01% f.s. (optional)
OP options 06 10 12 AC BR BT CP M6 TEV
= Adapter flange for Ø58 encoder with Ø6 axis (06A for the provision of a Ø6 coupling device without flange) = Adapter flange for Ø58 encoder with Ø10 axis = Adapter flange for Ø90 encoder with Ø12 axis (12A for the provision of a Ø6 coupling device without flange) = Complete anodizing = Cleaning brush for the cable = Low temperature (down to -30°C) = Fixing of the measuring cable with a clevis = Fixing of the measuring cable with a M6 threaded rod = Water evacuation holes + ex. 180 for 180° holes (see the options page for further details)
If no option is specified for the adapter flange, the draw-wire sensor will be supplied as standard with a Ø10 coupling brace without a flange. For the adaptation of an encoder or other sensor device which does not belong to our range, please contact us.
Reference example: CDS1850-MEC-50000-500-L05-OP-10-AC
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
82
Dimensional Drawing Oldham coupling adaptable to the detection element that will be mounted (see options)
200
10
100
179
190
180
50
+0,05 +0,02
180
180 200
432
180
10
Modular base plate
75 20
30
21,50
50
20 90
100
218,50 170
255
11
9
28,50 48,50
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
83
AS40 potentiometric output – Measurement range from 90 to 3600° Specifications: Measurement range Output signal Resolution Material
90 to 3600° 1kΩ Potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 303 10mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,25% fs (other values on demand) ≤ 300m.s-2 (11 ms) ≤ 100m.s-2 (10 … 500 Hz) IP65 (other on demand) ≈ 200 g -10° to +70°C -20° to +100°C
Axis diameter Detection element Connection
Linearity Shock resistance Vibration resistance Protection class Weight Operating temperature Storage temperature
Ordering reference:
AS40
OP
Model AS40 Measurement range 0090 = 90° 0180 = 180° 0340 = 340° 1800 = 1800° 3600 = 3600° (other values on demand) Output signal R01K = 1kΩ output (Other values on demand) Output sense H A
= CW = CCW
Linearity L50 L25 L15
= +/- 0.50% FS (standard for ranges up to 340°) = +/- 0.25% FS (standard for ranges superior than 340°) (optional for ranges up to 340°) = +/- 0.15% FS (optional for ranges superior than 340°)
Connection C L4 K
= Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options IP67
= Protection class IP67
Reference example: AS40-3600-R01K-H-L25-K02-OP-IP67
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
84
Dimensional Drawing C connection (Connector M16 - DIN 3 pin )
2 40
3
3 x M3
5 at 120° 48
17
57,50
L4 connection (connector M12 - 4 pin)
17,50
K connection (PVC cable - 4 wires)
20
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
85
36 f7
32
1,50
20 f7
12,50
6 g7
3
28
AS40 Analog output – Measurement range from 90 to 3600° Specifications: Measurement range Output signal
90 to 3600° - 0…10V - 4…20mA Current loop - 4…20mA Current generator - 0…20mA Current generator Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 303 10mm Multi-turn Hybrid potentiometer Male connector M16 – 8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,25% fs (other values on demand) ≤ 300m.s-2 (11 ms) ≤ 100m.s-2 (10 … 500 Hz) IP65 (other on demand) ≈ 200 g -10° to +70°C -20° to +100°C
Resolution Material Axis diameter Detection element Connection
Linearity Shock resistance Vibration resistance Protection class Weight Operating temperature Storage temperature
Ordering reference:
AS40
OP
Model AS40 Measurement range 0090 = 90° 0180 = 180° 0340 = 340° 1800 = 1800° 3600 = 3600° (other values on demand) Output signal U010 I420 I420G I020G
= Output 0…10V = Output 4…20mA (2-wires current loop) = Output 4…20mA (current generator) = Output 0…20mA (current
Output sense H A
= CW = CCW
Linearity L50 L25 L15
= +/- 0.50% FS (standard for ranges up to 340°) = +/- 0.25% FS (standard for ranges superior than 340°) (optional for ranges up to 340°) = +/- 0.15% FS (optional for ranges superior than 340°)
Connection C L4 K
= Male connector M16 – 8 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options IP67
= Protection class IP67
Reference example: AS40-3600-i420-H-L25-K02-OP-IP67
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
86
Dimensional Drawing C connection (Connector M16 - DIN 8 pin )
2 3
40
3 x M3
5 at 120° 60
17
69,50
L4 connection (connector M12 - 4 pin)
17,50
K connection (PVC cable - 4 wires)
20
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
87
36 f7
20 f7
1,50
32
12,50
6 g7
3
28
AS58 potentiometric output – Measurement range from 90 to 3600° Specifications: Measurement range Output signal Resolution Material
90 to 3600° 1kΩ Potentiometer (other values on demand) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 303 10mm Multi-turn Hybrid potentiometer Male connector M16 – DIN 3 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,50% fs – Range from 340° and 1080° +/- 0,25% fs – Range from 1800° and 3600° Range from 340° and 1080° (optional) +/- 0,15% fs – Range from 1800° and 3600° (optional) ≤ 500m.s-2 (6 ms) ≤ 100m.s-2 (55 … 2 000 Hz) IP54 (option IP67) ≈ 300 g -20° to +80°C -30° to +80°C
Axis diameter Detection element Connection
Linearity
Shock resistance Vibration resistance Protection class Weight Operating temperature Storage temperature
Ordering reference:
CD50
OP
Model CD50 Measurement range 0340 1080 1800 3600
= 0 to 340° = 0 to 1080° = 0 to 1800° = 0 to 3600°
Output signal R01K = 1kΩ output (Other values on demand) Linearity L50 L25 L15
= +/- 0.50% fs (standard for range from 340° and 1080°) = +/- 0.25% fs (standard for range from 1800° and 3600°) (optional for range from 340° and 1080°) = +/- 0.15% fs (optional for range from 1800° and 3600°)
Connection C L4 K
= Male connector M16 – DIN 3 pin = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BT IP67
= Complete anodizing = Low temperature (down to -30°C) = Protection class IP67
Reference example: AS58-3600-R01K-H-L25-K02-OP-IP67
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
88
Dimensional Drawing C connection (Connector M16 - DIN 3 pin )
58 2
36
31,75
10 g7
48
3 x M3 11,50
78
10
6 at 120°
19 3 x M4
6 at 120°
L4 connection (connector M12 - 4 pin)
16,50
K connection (PVC cable - 4 wires)
20
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
89
AS58 Analog output – Measurement range from 90 to 3600° Specifications: Measurement range Output signal
90 to 3600° 0…10V (galvanic isolation) 4…20mA ; 2 wires technique 4…20mA ; 4 wires technique (galvanic isolation) 0…20mA ; 4 wires technique (galvanic isolation) Quasi infinite (depends on the operating system) Body and cover - Aluminium (RohS) Measuring cable – Stainless steel 303 10mm Multi-turn Hybrid potentiometer Male connector M16 –8 pin Male connector M12 – 4 pin PVC cable – 4 wires +/- 0,50% fs – Range ≤ 340° +/- 0,25% fs – Range > 340° Range ≤ 340° (optional) +/- 0,15% fs – Range > 340° (optional) 500m.s-2 (6 ms) 100m.s-2 (55 … 2 000 Hz) IP54 (option IP67) ≈ 700 g -20° to +80°C -30° to +80°C
Resolution Material Axis diameter Detection element Connection
Linearity
Shock resistance Vibration resistance Protection class Weight Operating temperature Storage temperature Ordering reference: AS58
OP
Model AS58 Measurement range 0340 = 0 to 340° 1080 = 0 to 1080° 1800 = 0 to 1800° 3600 = 0 to 3600° (Other values on demand) Output signal U010 I420 I420G I020G
= 0…10V = 4…20mA (2 wires technique) = 4…20mA (4 wires technique) = 0…20mA (4 wires technique)
Linearity L50 L25 L15
= +/- 0.50% fs (standard for ranges from 340° to 1080°) = +/- 0.25% fs (standard for ranges from 1800° to 3600°) (optional for ranges from 340° to 1080°) = +/- 0.15% fs (optional for ranges from 1800° to 3600°)
Connection C L4 K
= Male connector M16 – DIN 8 = Male connector M12 – 4 pin = PVC cable – 4 wires + ex: 02 for cable 2 meters long
OP Options AC BT IP67
= Complete anodizing = Low temperature (down to -30°C) = Protection class IP67
Reference example: AS58-3600-U010-H-L25-K02-OP-IP67
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
90
Dimensional Drawing
C connection (Connector M16 - DIN 8 pin )
58 2
36
31,75
10 g7
48
3 x M3 11,50
78
10
6 at 120°
19 3 x M4
6 at 120°
L4 connection (connector M12 - 4 pin)
16,50
K connection (PVC cable - 4 wires)
20
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual - Version 2.0 Made in France
91
Electrical characteristics for draw-wire sensors with potentiometric output
Potentiometric version 1 K : (other values on demand) Temperature drift
+/-50 ppm/°C
Example of wiring diagram with input stage :
To ensure a good linearity, wire the potentiometer as a voltage divider and never as a rheostat. The input resistance of the operating system must be very high (greater than 10MΩ)
Connection : Male connector M16 3 pin (DIN)
Male connector M12 4 pin (DIN)
PVC cable 4 wire
R01K
1
1
Brown
Input voltage +
2
2
White
Input voltage GND
3
3
Green
Signal +
Sensor side view
Sensor side view
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
92
Electrical characteristics for draw-wire sensors with analog output Analog version 0 … 10V : Input voltage Output voltage Output current Galvanic isolation Protection
15 to +27 Vdc (52mA max) 0 to 10 Vdc 10mA max 3KV - Short circuit - Polarity reversal +/-100 ppm/°C
Temperature drift
Analog version 4 … 20mA : (Two-wires current loop) Input voltage Output current Protection
+15 to +27 Vdc (32mA max) 4 to 20mA - Short circuit - Polarity reversal +/-100 ppm/°C
Temperature drift
Analog version 4…20mA or 0…20mA : (Current generator) Input voltage Output current Output current Galvanic isolation Protection
+15 to +27 Vdc (75mA max) 4 to 20mA or 0 to 20mA 22 mA max. 3KV - Short circuit - Polarity reversal +/-100 ppm/°C
Temperature drift
Connection :
Male connector M16 8 pin (DIN)
Male connector M12 4 pin (DIN)
PVC cable 4 wire
010V
I420 (current loop)
I420G or I020G (current generator)
1
1
Brown
Input voltage +
Signal +
Input voltage +
2
2
White
Input voltage GND
Signal -
Input voltage GND
3
3
Green
Signal +
Signal +
4
4
Yellow
Signal GND
Signal GND
Sensor side view
Sensor side view
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
93
Electrical characteristics for draw-wire sensors with incremental output Electronic 2G2 (100kHz) (for CD50)
Electronic 5G5 (100kHz)
Supply : 5Vdc 10% Cons. without load : 100mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 2,5Vdc
Supply: 11 à 30Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc
Electronic 9G5 (100kHz)
Electronic PG5 (100kHz) (for CD50)
Supply: 5 à 24Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc
Supply: 5 à 30Vdc Cons. without load: 75mA max Current per channel: 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-3Vdc
Electronic 2G2 (100°C, 300kHz)
Electronic PG5 (100°C, 300kHz)
Supply : 5Vdc 10% Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 4Vdc
Supply : 5 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = Vcc-2,5Vdc
Electronic RG2 (100°C, 300kHz)
Electronic 5GT (70°C, 120kHz)
Supply : 4,75 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 0,5Vdc 1 min (Is=20mA) : Voh = 4Vdc
Supply : 11 to 30Vdc Cons. without load : 75mA max Current per channel : 40mA max 0 max (Is=20mA) : Vol = 1,5Vdc 1 min (Is=20mA) : Voh = Vcc-2,5Vdc
Connection: Male connector M23 12 Pin - CW
Male connector M23 12 Pin - CCW
Male connector M16 8 pin (DIN)
Male connector M16 5 pin (DIN)
PVC cable 8 wire
1
10 + 11
1
1
White
2
2 + 12
2
2
Brown
3
8
3
3
Green
Grey
A
4
5
4
4
Yellow
Brown
B
5
3
5
5
Grey
Red
0
6
1
6
/
Pink
Pink
A/
7
6
7
/
Blue
Green
B/
8
4
8
/
Red
Black
0/
PUR cable 12 wire White + White/Green Brown + Brown/Green
Standard connection Supply Supply +
PUR 12-LeiterKabel Sensor side view
Sensor side view
Sensor side view
Sensor side view
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
94
Options for draw-wire sensors, CD Series Cable attachment with a lug :
Cable attachment with a clip :
Standard
OP-EM
The attachment lug is fixed with a M6 screw or a clevis.
This fastening system allows a rotation about its axis. The clip is fixed with a M4 screw or a clevis.
Available for : CD50, CD60, CD80, CD115, CD150
Available for : CD50, CD60, CD80
Cable attachment fitted with a M4 threaded rod:
Cable attachment with a clevis :
OP-M4
OP-CP
The rod attachment uses a threaded rod with 2 nuts (provided). The required thickness of the plate does not exceed 5 mm.
The attachment of the clevis is done using a pin (provided). Available for : CD50, CD60, CD80, CD115, CD150
Caution Never screw the threaded rod into a fixed nut, a twist of the measurement cable would damage it.
Available for : CD50, CD60, CD80, CD115, CD150
Cable dust wiper
Cable cleaning brush:
OP-RAC
OP-BR
The dust wiper cleans the cable in dusty or humid environments.
The cleaning brush wipes the cable in dusty or humid environments.
Available for : CD50
Available for : CD60, CD80, CD115, CD150
Water evacuation holes: OP-TEV The holes allow the natural flow of fluids out of the sensor in order to avoid their accumulation in the system.
Available for : CD50, CD60, CD80, CD115, CD150
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
95
Options for draw-wire sensors, CDS Series
Cable attachment with a lug :
Cable attachment fitted with a M6 threaded rod:
Standard
OP-M6
Measuring cable attachment with a lug. The attachment mounted on ball bearings allows a free rotation relative to the measurement cable.
The rod attachment uses a threaded rod with 2 nuts (provided). The required thickness of the plate does not exceed 8mm. The attachment mounted on ball bearings allows a free rotation relative to the measurement cable.
Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Cable cleaning brush:
Cable attachment with a clevis :
OP-BR
OP-CP
The cleaning brush wipes the cable in dusty or humid environments.
The attachment of the clevis is done using a pin (provided). The attachment mounted on ball bearings allows a free rotation relative to the measurement cable.
Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Water evacuation holes: OP-TEV The holes allow the natural flow of fluids out of the sensor in order to avoid their accumulation in the system. Available for : CDS1210, CDS1215, CDS1820, CDS1830, CDS1840, CDS1850
Please specify the implantation angle of the drain holes on the drawing below. (All value between 0 and 360°)
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
96
Adapter flanges Adaptation for an encoder of diameter 58mm, and shaft diameter 6mm OP-06: Adaptation flange + Ø6 Oldham coupling OP-06A: Ø6 Oldham coupling without adaptation flange
Adaptation for an encoder of diameter 58mm, and shaft diameter 10mm OP-10: Adaptation flange + Ø10 Oldham coupling Without specification, a MEC series draw-wire sensor will always be delivered with an Oldham coupling Ø10 without adaptation flange.
Adaptation for an encoder of diameter 90mm, and shaft diameter 12mm OP-12: Adaptation flange + Ø12 Oldham coupling OP-12A: Ø12 Oldham coupling without adaptation flange
We reserve the right to make technical alterations without prior notice – Photos and drawings are not contractual – Version 2.0 Made in France
97
Connectors
Female connectors
M12 4-Pins Female connector For M-connection Ø of the cable: 4 to 6 mm Ref : 5100-020
M16 Female connector - DIN For C-connection (3-Pins) Ø of the cable: 4 to 6 mm Ref: 5100-007
M16 Female connector - DIN For C-connection (8-Pins) Ø of the cable: 4 to 6 mm Ref: 5100-008
M23 CCW female connector For G6-connection (mounting on CW baseplate) Ø of the cable: 6 to 8 mm Ref: 5100-006
M23 CW female connector For G8-connection (mounting on CCW baseplate) Ø of the cable: 6 to 8 mm Ref: 5100-005
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
98
Mounting accessories Magnet clamp FAIM-5 (for CD50)
Magnet clamp FAIM-25 (for CD115 and CD150)
Pulley PR01 (for CD50)
Pulley PR03
Cable extension
Heating module for draw-wire sensors, series CDS
- M4 cable plugs on both ends. Ref. : RL-XXXX-M4/M4
The heating module prevents the sensor to freeze under negative operating temperature. Don’t hesitate to contact us for any further information
- Attachment heads on both ends. Ref. : RL-XXXX-CP/CP
- Cable lugs on both ends. Ref. : RL-XXXX-CO/CO
Other possibilities: RL-XXXX-M4/CO (M4 screw at one end – lug on the other) RL-XXXX-M4/CP (M4 screw at one end – attachment head on the other) RL-XXXX-CO/CP (Lug at one end – attachment head on the other Possibility to integrate directly the cable extension into the sensor
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
99
Accessories Clearance compensation angle
Fixation angle
Ref : ERJ40-002
Ref : EF058-001
Measuring wheel
Oldham coupling
Ref : RM200-001
Cylindrical eccentric (to mount angular sensors and optical encoders) Provided with a set of 4 eccentrics + 4 screws Ref : EXC-001
Ref : EXC-002
We reserve the right to make technical alterations without prior notice - Photos and drawings are not contractual – Version 2.0 Made in France
100