Preview only show first 10 pages with watermark. For full document please download

Lithium/manganese Dioxide Battery Li Mno 2

   EMBED


Share

Transcript

Li/MnO2 ® DL123A Size: 2/3A Lithium/Manganese Dioxide Battery Inches 1.358 1.336 .665 .650 .475 .252 .248 .060 .051 .033 .030 .025 .665 .650 .252 .248 R .030 MAX. .051 (+) 1.358 1.336 .033 .025 SPECIFICATIONS Nominal Voltage: 3.0 V Typical Voltage: 3.2 – 3.3 V Rated Capacity: 1,400 mAh at 100 Ω to 2.0 V at 20°C (68°F) Average Weight: 0.60 oz. (17.0 g) Volume: 0.438 in.3 (7.18 cm3) Terminals: Flat, Recessed Negative Terminal Operating Temp. -40°C to 60°C Range: (-40°F to 140°F) NEDA/ANSI: 5018 LC IEC: CR17345 mm 34.50 33.93 16.89 16.51 12.07 6.40 6.30 1.52 1.30 0.84 0.76 0.64 (–) .060 MIN. .475 Note: Designed for 3-volt user-replaceable application. Dimensions are nominal unless otherwise indicated. DELIVERED CAPACITY VS. CURRENT DELIVERED CAPACITY VS. LOAD 1.8 1.8 1.6 1.6 60°C (140°F) AMPERE HOURS (Ah) AMPERE HOURS (Ah) 60°C (140°F) 1.4 20°C (68°F) 1.2 1.0 0°C (32°F) 0.8 0.6 0.4 1.4 20°C (68°F) 1.2 1.0 0°C (32°F) 0.8 0.6 0.4 -20°C (-4°F) -20°C (-4°F) 0.2 0.2 0.0 0.0 10 20 30 50 100 200 300 500 CONTINUOUS DISCHARGE CURRENT (mA) TO 2.0 VOLTS CUTOFF 1000 2 5 10 20 50 100 200 CONTINUOUS DISCHARGE LOAD (OHMS) TO 2.0 VOLTS CUTOFF INC. New Products and Technology Division Berkshire Corporate Park Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-431-2656 Outside North America: 203-791-3274 Facsimile: 203-791-3273 Internet: www.duracellnpt.com Printed in U.S.A. on recycled paper, please recycle after use. This data sheet is under document control and is therefore subject to change. Contact Duracell for the latest information. DL123A-2/93 ® Li/MnO2 Battery CONTINUOUS DISCHARGE AT 60°C (140°F) 2.5 2.0 1.5 0.1 5Ω 8Ω 1.0 16Ω 10 100 0.1 2Ω 5Ω 8Ω 16Ω 1.0 10 47Ω 100Ω 200Ω 100 1000 DISCHARGE TIME (HOURS) DISCHARGE TIME (HOURS) CONTINUOUS DISCHARGE AT 0°C (32°F) CONTINUOUS DISCHARGE AT -20°C (-4°F) TEST CONDITIONS LOAD DRAIN 2Ω = 1041mA 5Ω = 434mA 8Ω = 277mA 16Ω = 148mA 47Ω = 52mA 100Ω = 25mA 200Ω = 13mA 2.5 2.0 TEST CONDITIONS LOAD DRAIN 2Ω = 929mA 5Ω = 398mA 8Ω = 253mA 16Ω = 130mA 47Ω = 45mA 100Ω = 22mA 200Ω = 12mA 3.0 VOLTAGE (V) VOLTAGE (V) 1.0 0.01 1000 1.5 2.5 2.0 1.5 2Ω 0.1 1.0 5Ω 8Ω 16Ω 47Ω 100Ω 200Ω 10 100 2Ω 1.0 0.01 1000 0.1 5Ω 8Ω 1.0 16Ω 47Ω 100Ω 200Ω 10 100 1000 DISCHARGE TIME (HOURS) DISCHARGE TIME (HOURS) PULSE DISCHARGE AT DIFFERENT DUTY CYCLES 1.2A, AT 20°C (68°F) PULSE DISCHARGE AT DIFFERENT TEMPERATURES 1.2A, 3 SECONDS ON/7 SECONDS OFF 2.4 TEST CONDITIONS 20°C (68°F) 10% - 3 sec on/ 27 sec off 30% - 3 sec on/ 7 sec off 50% - 3 sec on/ 3 sec off 2.2 VOLTAGE (V) 3.0 VOLTAGE (V) 2.0 47Ω 100Ω 200Ω 3.0 1.0 0.01 2.5 1.5 2Ω 1.0 0.01 TEST CONDITIONS LOAD DRAIN 2Ω = 1124mA 5Ω = 486mA 8Ω = 311mA 16Ω = 161mA 47Ω = 58mA 100Ω = 28mA 200Ω = 14mA 3.0 VOLTAGE (V) VOLTAGE (V) CONTINUOUS DISCHARGE AT 20°C (68°F) TEST CONDITIONS LOAD DRAIN 2Ω = 1185mA 5Ω = 520mA 8Ω = 333mA 16Ω = 175mA 47Ω = 59mA 100Ω = 28mA 200Ω = 14mA 3.0 DL123A 2.5 10% 2.0 2.0 0°C (32°F) 1.8 -20°C (-4°F) 1.6 1.4 1.5 30% 1.2 50% 1.0 1.0 0 50 100 150 DISCHARGE TIME (MINUTES) 200 250 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 DISCHARGE TIME (HOURS)(360 PULSES/HR) 4.0