Transcript
LL671-14*1D, 2D
With FLEXI-GUARD
®
Installation/Care/Use Manual USES HFC-134A REFRIGERANT
SEE FIG. 4
SEE FIG. 3
7
28
29
17, 18, 19, & 20 15 & 16
22, 23, 24, & 25
21
27 & 30
13
26
14
31 & 32
FIG. 1
PAGE 1
97350C (Rev. B - 11/02)
97350C (Rev. B - 11/02)
PAGE 2
LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm) FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2" (38 mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS. EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E. CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38 mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼ DE DIÁMETRO. EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU. C = 1-1/4 TRAP NOT FURNISHED PURGADOR DE 1¼ NO PROPORCIONADO SIPHON 1-1/4 NON FOURNI D = ELECTRICAL OUTLET LOCATION UBICACIÓN DE LA TOMA DE ELECTRICIDAD EMPLACEMENT DE LA PRISE DE COURANT
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL. ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE MUR. F = POWER CORD 4 FEET (1219mm) LONG CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO CORDON DALIMENTATION 4' (1219mm) G = ALT. ELECTRICAL OUTLET LOCATION UBICACIÓN ALT. DE LA TOMA DE ELECTRICIDAD EMPLACEMENT ALTERNATIF DE LA PRISE DE COURANT
FIG. 2
FINISHED FLOOR PISO ACABADO PLANCHER FINI
LL671-14*1D, 2D
LL671-14*1D, 2D
10
8
9
11
BASIN
12
NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN NUT (ITEM 12) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN. FIG. 3
Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove Items 1 & 2 and adjust screw on Item 4. Clockwise adjustment will raise stream and counter-clockwise adjustment will lower stream. For best adjustment, stream should hit basin approximately 6-1/2" (165mm) from bubbler.
1 2 3
4 5
BASIN 6
FIG. 4
PAGE 3
97350C (Rev. B - 11/02)
LL671-14*1D, 2D PARTS LIST 115V ITEM NO.
PART NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22* 23 24 25 26 27 28 29 30 31 32
40089C 40048C 15005C 61313C 40169C 50986C 20776C 56073C 40322C 56011C 55997C 75580C 31513C 31502C 61013C 21516C 31490C 30664C 20239C 70018C 66202C 35762C 31027C 35766C 194243901550 55996C 45693C 66229C 66505C 50368C 27247C 27248C
DESCRIPTION Cover Button Regulator Retaining Nut Regulator Hex Nut Regulator Holder Basin Bubbler Assy Orifice Assy Housing Assy Pedestal Bubbler Locknut Cold Control Power Cord Condenser Fan Shroud Fan Motor Fan Blade Fan Bracket Fan Blade Nut Drier Compressor Serv. Pak Overload/Relay Assy Relay Cover Electrical Shield Strainer Precooler Heat Exchanger Evaporator Receptor-Drain Base Angle
220/240v 50/60 Hz ITEM NO.
PART. NO.
14 17 22* 23 24
31440C 31430C 35764C 31028C 35768C
DESCRIPTION Power Cord Fan Motor Compressor Serv. Pak Overload/Relay Assy Relay Cover
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.
COLOR TABLE
LEFT PANEL
RIGHT PANEL
FRONT PANEL
Gray Beige Almond Stainless Steel Sandalwood Granite Light Gray
21072C 21472C 21080C 21470C 27159C 28387C
21073C 21473C 21081C 21471C 27162C 28388C
20675C 20676C 20672C 21454C 27150C 21455C
PRINTED IN U.S.A.
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620