Transcript
ZODIAC DATA SYSTEMS GMBH AEROSAFETY & TECHNOLOGY Telemetry & Telecommunications - HEIM
HEIM DATaRec® 4 LMF2FE + Rec + LEMO (HS300-0120/0) Technical Specification Link Modules
General
USB 2.0 Front end mode
®
max. 200 Mbit/s max. 80 Mbit/s
The HEIM DATaRec 4 Link Module is the central processing module and is used to create a single datastream from multiple signal interface subsystems. A subsystem consists of max. 8 Signal Modules. The Link Module LMF2FE+Rec+LEMO supports up to 16 Signal Modules with up to 384 signals split into 2 subsystems.
Standalone mode
Data acquired from the Signal Modules can either be transferred via IEEE 1394b, Gigabit Ethernet and USB 2.0 to an analysis computer (front-end mode) and / or via IEEE 1394b or USB 2.0 to a storage device (standalone recorder mode).
Input level
7 digital inputs max. 36 V
Status output
7 open collector
Status output current
max. 60 mA, max. 36 V
Time code inputs / outputs
Cable length subsystem Cable length between 2 modules Contact remote input
up to 50 m up to 10 m
SMM Storage Modules
IRIG-A, -B, -G in / out PPS in / out 1) GPS serial RS232/RS422 IEEE 1394b, USB 2.0 (target) Gbit Ethernet (10/100/1000 base T) IEEE 1394b, USB 2.0 (HOST), Interface to DATaRec 4 200 Mbit/s
LMF2FE+Rec+LEMO (HS300-0120/0)
RTC
yes, battery powered
Link module
Time accuracy
20 ppm
Dimensions
Since the Link Module provides the time basis for the connected Signal Modules a high precision synchronisation of all signals is always guaranteed. Furthermore the Link Module controls the calibration, the phase alignment, and gives build in test (BIT) options for the whole system during setup of a new system configuration or normal operation.
Computer interface Storage interface
Link module bit rate
up to 600 Mbit/s
HEIMLink chains
2
Weight
70.1 x 184 x 124.5 mm (w x h x d) including fixing system 1.1 kg typical
Interface
Gigabit Ethernet, IEEE 1394b, USB 2.0
Cooling
switchable; temp. regulated fan
Power consumption
max. 30 W
Power input range
10 - 36 VDC
UDP Broadcast
max. 600 Mbit/s max. 500 Mbit/s
Input DC power monitoring
yes, with low power detection
IEEE 1394b
max. 180 Mbit/s
Power source
HEIMLink
Sustained interface bit rate Gbit Ethernet
ZODIAC Data Systems GmbH
Page 1 of 2
Document No.: TS_LMF2FE+Rec+LEMO_EN_130311_HD5432041010.doc
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice.
HEIM DATaRec® 4 LMF2FE + Rec + LEMO (HS300-0120/0) Technical Specification Link Modules
Connector
Notes
HEIMLink chain
2 * 9 pin LEMO connector
USB
standard host and target connector
IEEE 1394b
standard IEEE 1394b connector
Ethernet
standard RJ45 connector
Time
14 pin LEMO connector
Contact remote ®
DATaRec 4 SMM
16 pin LEMO connector 32 pin LEMO connector
Performance varies depending on the installation environment. The shown values were measured using an appropriately designed test ® system including the HEIM DATaRec 4 power supplies under nominal conditions of temperature, voltage, etc.. Performance is significantly influenced by storage medium type, host computer performance and load, used acquisition software, signal module configuration, power supplies and cabling.
Environmental specifications Vibration Shock
5g 10 g
Temperature operational
IEC 60068-2-14-Nb
Standalone module
Storage
-20 °C - 70 °C 1) -30 °C - 70 °C -10 °C - 55 °C 1) -20 °C - 55 °C -40 °C - 85 °C
Humidity
0 - 93% relative, non-condensing
EMI
DIN EN 61000-6-2 DIN EN 61000-6-4
Link chain system
1) 2)
under development special start-up procedure required
ZODIAC Data Systems GmbH Friedrich-Ebert-Strasse / TechnologiePark – D-51429 Bergisch Gladbach Tel.: +49 2204 84 41 00 – Fax: +49 2204 84 41 99
[email protected] – http://www.zodiac-data-systems.com ZODIAC Data Systems GmbH
Page 2 of 2
Document No.: TS_LMF2FE+Rec+LEMO_EN_130311_HD5432041010.doc
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice.