Preview only show first 10 pages with watermark. For full document please download

Lnb_4w Buc_letter_may2012

   EMBED


Share

Transcript

Ka-band 4W BUC Ka-band Satcom - Count on EM Solutions 30.0 to 31 GHz Input Frequency 950 to 1950MHz 1000 to 2000MHz (optional) Sense Non Inverting Output Power Psat 36dBm nom Gain 55dB Gain Flatness (Full Band) Gain Flatness (36MHz Channel) Gain Variation (Temperature) Input Return Loss Output Return Loss Ka-band BUC 4W Specifications 1. Output Frequency 1.5dB 0.3dB 2.0dB 14dB 14dB Tx Noise Rejection > 65dB @ 21.2GHz Phase Noise -75dBc/Hz at 1kHz -85dBc/Hz at 10kHz -95dBc/Hz at 100kHz -105dBc/Hz at 1MHz External Reference External Reference Level External Reference Phase Noise max 5MHz or 10MHz (optional) -5 to +5dBm -140dBc/Hz at 1kHz Input Power +17 to +30 V (IF CABLE) 1. Output Frequency 30.0 to 31 GHz Power Consumption 55W Input Frequency 950 to 1950MHz 1000 to 2000MHz (optional) Operating Tem perature -30 to +60 C Sense Non Inverting Weight 1500 grams Monitor & Control (FSK) Ouput Power Detector Gain Control (0 to -15dB) Summary Alarm Size: 220mm x 130mm x 48mm (8.7” x 5.1” x 1.9”) Output Power Psat 36dBm nom Gain 55dB Gain Flatness (Full Band) Gain Flatness (36MHz Channel) Gain Variation (Temperature) 1.5dB 0.3dB 2.0dB Input Return Loss Output Return Loss 14dB 14dB Tx Noise Rejection > 65dB @ 21.2GHz Phase Noise -75dBc/Hz at 1kHz -85dBc/Hz at 10kHz -95dBc/Hz at 100kHz -105dBc/Hz at 1MHz External Reference External Reference Level External Reference Phase Noise max 5MHz or 10MHz (optional) -5 to +5dBm -140dBc/Hz at 1kHz Input Power +17 to +30 V (IF CABLE) Power Consumption 55W Operating Tem perature -30 to +60 C Weight 1500 grams Monitor & Control (FSK) Ouput Power Detector Gain Control (0 to -15dB) Summary Alarm Size: 220mm x 130mm x 48mm (8.7” x 5.1” x 1.9”) 1. Other bands available Specifications current at May 2012, E & EO Linear Power Definition (Min of) (a) Combined power resulting from two equal carriers with 2.6MHz 1. Other bands available Specifications current at May 2012, E & EO Linear Power Definition (Min of) (a) Combined power resulting from two equal carriers with 2.6MHz separation at which the power in a single 3IMD product is 25dB below the combined power of the two CW signals or (b) Power measured at which the spectral regrowth of a half rate OQPSK modulated carrier is at least 30dB below the peak power spectral density one symbol rate removed from the carrier frequency. Solutions Innovation in Microwave Communications EM Solutions Pty Limited A.B.N. 33 082 157 846 101 Hyde Road (PO Box 3164), Yeronga, Queensland 4104, Australia P: +61 7 3392 7600 F: +61 7 3392 6400 E: [email protected] Visit us at: www.emsolutions.com.au Ka-band LNB Down Converter Ka-band Satcom - Count on EM Solutions Ka-BAND LNB SPECIFICATIONS 20.2 to 21.2 GHz Noise Figure: 1.3 dB typical/ 1.5 dB maximum, at 23˚C Input Connector: WR42 (WG20) flange with pressure window, Input Return Loss: 18 dB Input Stability: Unconditionally stable for all possible input loads IF Output Frequency: 950 to 1950 MHz Output Connector: N type Female, 50 ohm Output Return Loss: 15 dB Output Stability: Unconditionally stable for all possible output loads Conversion Gain: 60 dB nominal Gain Flatness: 2.5 dB p-p over full band 1 dB p-p over any 33 MHz segment Gain Variation over Temp: ± 2.0 dB maximum 1dB Compression Point: > 7 dBm 3rd Order Intercept: > 17 dBm Ka-band LNB Down Converter Specifications Ka-BAND LNB SPECIFICATIONS 1. 1. RF Input Frequency: External Ref 10 MHz, 0 dBm ± 3 dB, via IF connector Desensitisation: -30dBm (30 - 31GHz) Filtering: Includes embedded interstage Tx Filter >50 dB rejection RF Input Frequency: 20.2 to 21.2 GHz Noise Figure: 1.3 dB typical/ 1.5 dB maximum, at 23˚C Input Connector: WR42 (WG20) flange with pressure window, Image Rejection: > 50dBc Input Return Loss: 18 dB Phase Noise: 100Hz -63 dBc/Hz 1 kHz -80 dBc/Hz 10 kHz -90 dBc/Hz 100 kHz -100 dBc/Hz LO Leakage at Input: -80 dBm maximum Input Stability: Unconditionally stable for all possible input loads IF Output Frequency: 950 to 1950 MHz Output Connector: N type Female, 50 ohm Output Return Loss: 15 dB Output Stability: Unconditionally stable for all possible output loads Conversion Gain: 60 dB nominal Gain Flatness: 2.5 dB p-p over full band 1 dB p-p over any 33 MHz segment Gain Variation over Temp: ± 2.0 dB maximum 1dB Compression Point: > 7 dBm 3rd Order Intercept: > 17 dBm External Ref 10 MHz, 0 dBm ± 3 dB, via IF connector Desensitisation: -30dBm (30 - 31GHz) Filtering: Includes embedded interstage Tx Filter >50 dB rejection Image Rejection: > 50dBc Phase Noise: 100Hz -63 dBc/Hz 1 kHz -80 dBc/Hz 10 kHz -90 dBc/Hz 100 kHz -100 dBc/Hz LO Leakage at Input: -80 dBm maximum In Band Spurious: -65 dBm DC Input: +9 to 13 V DC, 400mA maximum, via IF connector Operating Temp: -30 to + 60˚C Relative Humidity: Up to 100% condensation and frost Mass: 350 grams Size: 51mm x 45mm x 100mm (2” x 1.8” x 3.9”) 1. In Band Spurious: -65 dBm DC Input: +9 to 13 V DC, 400mA maximum, via IF connector Operating Temp: -30 to + 60˚C Relative Humidity: Up to 100% condensation and frost Mass: 350 grams Size: 51mm x 45mm x 100mm (2” x 1.8” x 3.9”) Other bands available Specifications current at May 2012, E & EO Solutions Innovation in Microwave Communications EM Solutions Pty Limited A.B.N. 33 082 157 846 101 Hyde Road (PO Box 3164), Yeronga, Queensland 4104, Australia P: +61 7 3392 7600 F: +61 7 3392 6400 E: [email protected] Visit us at: www.emsolutions.com.au