LOAD DEMAND START STOP SYSTEM
P o w e r G r i d M o d e r n i z a t i o n f ro m L - 3 We s t w o o d
The Load Demand Start Stop (LDSS) System is L-3 Westwood’s next-generation approach to power grid modernization and was designed to work in conjunction with 30kW and 60kW, B Model, Tactical Quiet Generator (TQG) sets. The LDSS System can be utilized with as few as two TQG’s or up to a total of six TQG’s (30kW, 60kW, or a combination of sizes) and can be adapted to work with other types of generator sets.
LDSS SYSTEM BENEFITS
LDSS SYSTEM FEATURES
• Provides for connection of generator sets into a ring-bus, micro-grid power system configuration
• Demand initiated startup
• Power grid management system automatically starts and stops generator sets based upon load requirements • Reduces fuel consumption by up to 50% over traditional generator set operating methodology depending upon load profile • Reduces maintenance cost due to efficient utilization of generator sets
• Dry contact initiated start (manual starting from remote location) • Dry contact control of the auxiliary fuel system (manual enabling/disabling from a remote location) • Sequence and stagger generator use in a variety of methods, including by service time, generator set size, and individual unit ID • Demand initiated shutdown • Dry contact shutdown (manual shutdown from a remote location) • Automatic frequency and voltage matching during synchronization • Communication between controllers via PLC (Power Line Communication) or by hardwired Ethernet • Optional MODBUS control and monitoring from a remote location
Westwood Power Grid Modernization.indd 1
9/14/2011 2:28:50 PM
LOAD DEMAND START STOP SYSTEM
P o w e r G r i d M o d e r n i z a t i o n f ro m L - 3 We s t w o o d
LDSS SPECIFICATIONS Width 24
Customer inter face connector:
Height
12 in
P56-1
Remote star t
Depth
24 in
P56-2
Auxiliar y fuel enable
Weight
90 lbs
Operating temperature
-40°F to +135°F
Compatibility
MEP-805B & MEP-806B
Storage temperature
-65°F to +165°F
Generator set output voltage requirement
120/208 Volts 50 or 60 Hz
Optional remote monitoring and control
RS-485 via MODBUS® protocol
Microgrid capability
Any quantity Sequencing options • Smallest unit ID from 2 up to 6 first gensets can • Staggered ser vice be placed in time the microgrid. • Balanced ser vice Microgrid time composition • Largest size first can be 30kW • Smallest size first only, 60kW • Adopt system only, or a mode commination of both sizes
Communication between controllers
Hardwired System Adaptation Ethernet or optional Power Line Communication
Westwood 12042 E. 60th Street Tulsa, OK 74146 Tel: 918.252.0481 Fax: 918.294.0540 Email:
[email protected] L-3com.com/ Westwood
LDSS system can be adapted to work with other generator sets.
Contact us for more information Appropriate for public release as defined under ITAR 120.10(5). OFOISR 11-S-3166 on August 30, 2011.