Preview only show first 10 pages with watermark. For full document please download

Lockwood Smartair Ts1000 Installation Guide_1216

   EMBED


Share

Transcript

SMARTair ™ TS1000 Version 5.0 Installation Guide www.assaabloy.co.nz 1. System Overview A TS1000 5.00 software platform is composed of a Data Server and one or more clients accessing data from the server. All system data is stored in the Data Server and client access it through a server process listening at a TCP Port (by default TCP port 3050). In case of having an installation based on only one PC, the server and client are installed in the same machine. In an installation with many PCs, one PC must be selected to act as a server and the rest access it as clients. 2. Installation There is only one TS1000 installer to install both the Data Server and Clients. The installer asks the user to select server or client installation modes during the setup process. In case of having a single PC installation, server and client are installed on the same machine. In a multi-user installation, one full installation and several client-only installations must be run on different machines. Full Install Client-only Install System with 1 PC YES. Once Run full install in the PC NO System with N PCs YES. Once Run full install in the PC selected to be used as a Data Server YES. N-1 times Run client-only install in the rest of N-1 PCs 2.2 System Requirements These are the recommended system requirements for a TS1000 system: • PC with Pentium 4 or higher processor • 512 MB RAM • 1GB of free disk space • Windows XP Operating System or higher Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 2 2.3 Preparing the Installation Administrator rights are needed to install TS1000 5.0 software. Please contact your system administrator for more information on this. Before proceeding with the installation some decisions must be made. The most important one is to decide which machine to use to install the TS1000 Data Server. Please take into account; • The machine used as the Data Server must be always switched on in order to allow clients to access data. • Selecting the most powerful machine available as the Data Server will enhance all clients’ performance. 2.4 Uninstalling previous TS1000 versions On the Software USB device, supplied with the SmartAir Management Kit and Licence, click on the “TS1000 5.06 Setup.exe” file. The installer checks whether there is a previous TS1000 installation in the machine before proceeding. TS1000 5.00 software cannot be installed without uninstalling previous versions. 3 Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 2.5 Installation Procedure A welcome screen and a license agreement text are shown when the installer is run. Click on Next and agree the License Agreement to continue. Select the Destination Folder to copy files to and click on Next. By default “C:\SmartAir TS1000”. Data Server parameters can be configured at this stage of the setup process using the Server Settings screen. Click on the Install button to continue. Server Setting Default Value Description TCP Port TCP Port Data Server TCP listening port Data Folder Under Installation Directory Folder to store the physical database file in the server filesystem. Database alias default Alias for the default database id Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 4 Files will be copied and the system will be configured at this stage. Click on Show details to show the installation log Install Site Data (optional). Select ‘Yes’ when prompted to install Site Data. Use the ‘Browse’ button to select the Drive where the Software is being installed from, and find the “DATA.FDB” file, located in the ‘Data’ folder. Click on the ‘Next’ button and the Site data will be copied to the Data Server’s internal database file folder. 5 Lockwood SMARTair™ TS1000 Wall Reader Version for Elevators 5.0 Installation Guide assaabloy.co.nz The installer detects the Windows Firewall and opens the server’s TCP Port automatically when installing the Data Server. In case of having a third party firewall, please make sure that the TCP port used by the server is open in order to allow incoming TCP client connections. The configuration of the firewall is out of the scope of this document. To run the TS1000 software, click on the Shortcut on your Desktop. Operator Name: TS1000 Password: the last 6 digits of your License Number. 2.6 Client only Installation procedure On the Software USB device, supplied with the SmartAir Management Kit and Licence, click on the “TS1000 5.06 Setup.exe” file. Follow the normal installation procedure until you come to the Installation Type. Tick only the “TS1000 Client” box Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 6 To run the TS1000 software, click on the Shortcut on your Desktop or ‘Start’ - ‘Programs’ - TS1000 Operator Name: TS1000 Password: the last 6 digits of your License Number. 2.7 Configuring Clients In a multi-client system, clients must be configured to connect to a specific data server. This can be accomplished using the DATA and SERVER parameters in the Start menu shortcuts. SERVER: parameter identifies the server using its IP address or hostname while the; DATA: identifies a database inside a server. One server can manage multiple databases and that’s why the DATA parameter is needed. A database inside the server can be identified using the alias (defined at the server’s setup process) or using a full database file path. No configuration is needed in an installation based on only one PC where server and client run on the same machine. 7 Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 2.7.1 Specifying a Remote Data Server From the ‘Start’ menu, click on ‘Programs’ – ‘SmartAir TS1000 5.05’ Right Click on ‘TS1000’ and select ‘Properties’ You can also create a Shortcut either in the ‘C:\SmartAir TS1000’ Folder or into your Desktop where you can also then select properties in order to modify the above dialog box. Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 8 Client Configuration Parameters Parameter Format Description /SERVER:IP[/Port] • IP IP or hostname of the remote server • [/Port] Optional. Port number if it is different from 3050 /DATA:DatabaseID • DatabaseID Database Identifier inside the server. Can be either: o Database alias defined at server’s setup o Database file path: Existing server’s folder path+/FileName.fdb Client Configuration Parameters Format Examples: • Server located at 192.168.10.5 listening at default port 3050. Using the alias defined on server’s setup as a database id. /SERVER:192.168.10.5 /DATA:default • Server located at 192.168.10.5 listening at default port 3050. Using a full database file path as a database id. A valid database file path is any path to a *.fdb file inside an existing server folder. /SERVER:192.168.10.5 /DATA:C:\Data\Data.fdb • Server located at 192.168.10.5 listening at port 3052. Using the alias defined on server’s setup as a database id. /SERVER:192.168.10.5/3052 /DATA:default • Server located at 192.168.10.5.listening at port 3052. Using a full database file path as a database id. A valid database file path is an *.fdb file inside an existing server folder. /SERVER:192.168.10.5/3052 /DATA:C:\Data\DataFile_123.fdb Repeat the previous steps with the Tools and Wireless Tools applications. 3. Configuring the Data Server Backup management Backing up Data Server database files is highly recommended to avoid data loss in case of disk crash or Operating System failures. This can be easily automated using the Backup Manager. 9 Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 3.2. Scheduling automatic backups Click on the Start menu and find the SmartAir TS1000 5.06 program group. Then click on the ‘Backup Manager’. The Backup Manager must be configured the first time it is run. Click on the View->Options menu. Set the Startup options to ‘Service’ and ‘Automatic startup’. If you’re using Windows 95/98 or Me, select Application instead of Service. The default server database file is pre-configured in the Backup Manager. Select ‘Backup’, then ‘Properties’ and when the ‘Properties dialog box pops-up, select the ‘Target’ tab. Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 10 Select the Backup destination folder and click ‘OK’ to finish. Whilst still on the ‘Properties’ dialog box, select ‘Backup Plan’ and define your preferred plan before clicking ‘OK’ to finish. Back on the Main Backup Scheduler Window, click on ‘Backup’ then ‘Start’ to start the Backup Service. 11 Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 3.3. Restoring Backups The Backup Manager generates backup files in the target directory as set in the Backup plan. These Backups are restored using the “TS1000 Tools” program in the Data Server PC. In the ‘Tools’ main window, click on the ‘Restore Database Backup’ The application is password protected. Default ‘Operator Name’ is “TOOLS” and the Password is the last 6 digits of your software license. Go to the Backup Folder and select the file to Restore. Click on the ‘Open’ button to start the restoral process. When the Restoral process is complete, a pop-up window will appear. Lockwood SMARTair™ TS1000 Version 5.0 Installation Guide assaabloy.co.nz 12 Lockwood is the leading brand in the Australasian locking industry. With an established reputation for high quality products, this iconic brand provides a wide range of locking solutions to residential housing, commercial, semi-commercial, building and industrial application markets. Lockwood is supported by an extensive distribution and after‑sales support network. Our customers include retailers, architects, trade and industrial personnel, locksmiths and security dealers. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. ASSA ABLOY is represented in all major regions, in both mature and emerging markets, with leading positions in New Zealand, Australia, Europe and North America. As the world’s leading lock group, ASSA ABLOY offers a more complete product range of door opening solutions than any other company in the market. SMARTair™ offers an intelligent, yet simple, step up from keys, and a cost effective alternative to traditional access control. No bells, whistles, or wires, just sleek, reliable security. For full details of Lockwood Warranties, please visit www.assaabloy.co.nz/warranties ASSA ABLOY New Zealand Ltd 6 Armstrong Road Albany, Auckland 0632 New Zealand [email protected] assaabloy.co.nz