Preview only show first 10 pages with watermark. For full document please download

Logo!power 12

   EMBED


Share

Transcript

© Siemens AG 2008 LOGO!Power LOGO!Power 15 V ■ Overview ■ Application ■ Technical specifications Power supply, type 15 V/1.9 A 15 V/4 A Order No. 6EP1 351-1SH02 6EP1 352-1SH02 Input Rated voltage Vin rated Single-phase AC 100 - 240 V AC Wide-range input 85 ... 264 V AC Single-phase AC 100 - 240 V AC Wide-range input 85 ... 264 V AC Overvoltage strength 2.3 x Vin rated/1.3 ms 2.3 x Vin rated/1.3 ms Mains buffering at Iout rated Rated line frequency, rated line-frequency range Rated current Iin rated Switch-on current limit (+25 °C) > 40 ms at Vin = 187 V 50/60 Hz, 47 ... 63 Hz > 40 ms at Vin = 187 V 50/60 Hz, 47 ... 63 Hz 0.63 ... 0.33 A < 15 A 1.24 ... 0.68 A < 30 A I 2t Built-in line-side fuse Recommended miniature circuit breaker (IEC 898) in the mains power input < 0.8 A2s Internal From 16 A, Characteristic B or from 10 A, Characteristic C < 3 A2s Internal From 16 A, Characteristic B or from 10 A, Characteristic C Output Rated voltage Vout rated Total tolerance, static • Static mains compensation • Static load smoothing Controlled, isolated DC voltage 15 V DC ±3 % Approx. 0.1 % Approx. 1.5 % Controlled, isolated DC voltage 15 V DC ±3 % Approx. 0.1 % Approx. 1.5 % Residual ripple Spikes (bandwidth approx. 20 MHz) Adjustment range Status display Response on activation/deactivation < 200 mVpp (typ. 10 mVpp) < 300 mVpp (typ. 30 mVpp) 10.5 ... 16.1 V Green LED for output voltage OK No overshoot of Vout (soft start) < 200 mVpp (typ. 10 mVpp) < 300 mVpp (typ. 40 mVpp) 10,5 ... 16,1 V Green LED for output voltage OK No overshoot of Vout (soft start) Startup delay/ voltage rise Rated current Iout rated Current range to +55 °C Parallel switching for enhanced performance < 0.5 s/typ. 15 ms < 0.5 s/typ. 10 ms 1.9 A 0 ... 1.9 A Yes 4A 0 ... 4 A Yes Voltage range 12 The power supplies of the LOGO!Power range are primary switched-mode devices that are optimally matched to the LOGO! logic modules in their functionality and design. With the wide-range input 85 V to 264 V AC, radio interference level B and option for installing in built-in miniature distribution boards, they can be used universally in a diverse range of applications in the low-end performance range. Continued on page 12/7. 12/6 Siemens KT 10.1 · 2008 © Siemens AG 2008 LOGO!Power LOGO!Power 15 V Power supply, type 15 V/1.9 A 15 V/4 A Order No. 6EP1 351-1SH02 6EP1 352-1SH02 Efficiency Efficiency at Vout rated, Iout rated Power losses at Vout rated, Iout rated Approx. 80 % Approx. 7 W Approx. 85 % Approx. 11 W <0.2 % Vout <0.2 % Vout Typ. ± 2.8 %Vout Typ. ± 3.3 %Vout Typ. 20 ms Typ. 20 ms Typ. 20 ms Typ. 20 ms Typ. 2.7 A Constant current characteristic <4A Typ. 5.0 A Constant current characteristic <8A – – Yes, safety extra-low output voltage Vout to EN 60950 and EN 50178 Class II (without protective conductor) Yes; CB scheme Yes, safety extra-low output voltage Vout to EN 60950 and EN 50178 Class II (without protective conductor) Yes; CB scheme Yes cULus-listed (UL 508, CSA C22.2 No. 14), File E197259; cURus-recognized (UL 60950, CSA C22.2 No. 60950), File E151273 Yes cULus-listed (UL 508, CSA C22.2 No. 14), File E197259; cURus-recognized (UL 60950, CSA C22.2 No. 60950), File E151273 FM approval Marine approval Degree of protection (EN 60529) Class I Div. 2, Group A, B, C, D T4 GL IP20 Class I Div. 2, Group A, B, C, D T4 GL IP20 EMC Emitted interference Supply-harmonics limitation Noise immunity EN 55022 Class B Not applicable EN 61000-6-2 EN 55022 Class B Not applicable EN 61000-6-2 Closed-loop control Dyn. mains compensation (Vin rated ± 15 %) Dynamic load smoothing (Iout: 10/90/10 %) Load step settling time • 10 to 90 % • 90 to 10 % Protection and monitoring Current limit Short-circuit protection Sustained short-circuit current rms value Overload/short-circuit indicator Safety Primary/secondary electrical isolation Protection class German Technical Inspectorate approval CE mark UL/cUL (CSA) approval Operating data Ambient temperature range – 20 ... +55 °C with natural convection Transport/storage temperature range – 40 ... +70 °C Humidity class Climate class 3K3 to EN 60721, no condensation Mechanics Supply-input connections L1, N Connections • Output + • Output – Dimensions (W x H x D) in mm Weight, approx. Installation – 20 ... +55 °C with natural convection – 40 ... +70 °C Climate class 3K3 to EN 60721, no condensation One screw terminal each for 0.5 ... 2.5 mm2 single-core/finely stranded One screw terminal each for 0.5 ... 2.5 mm2 single-core/finely stranded 2 screw terminals for 0.5 ... 2.5 mm2 2 screw terminals for 0.5 ... 2.5 mm2 54 x 90 x 55 0.17 kg Snaps onto DIN rail EN 60715 35x7.5/15 72 x 90 x 55 0.25 kg Snaps onto DIN rail EN 60715 35x7.5/15 12 Siemens KT 10.1 · 2008 12/7