User’s Manual
Long Range Handheld CCD Scanner 25-LGZ01-01 Ver. 1.1 Nov. 2001
8 Olympic Drive Orangeburg, NY 10962 Tel 845.365.0090 Fax 845.365.1251
www.opticonUSA.com
Table of Contents
PART I – General Information CCD Scanning UnPacking. Factory Service. Installation
Page 4
PART II — Bar Code Menu Functions Programming the Scanner Reset all Defaults
Page 6
SECTION A: INSTALLATION AND SET-UP Keyboard Wedge Interface Computer Type Selection Keyboard Language Selection Message Terminator RS-232 Interface Handshaking Protocol Baud Rate Data Bits/Stop Bits/Parity Message Terminator ACK/NAK Wand Emulation Speed Selection Output Selection Narrow / Wide Ratio
Page 8
Page 10
Page 12
SECTION B: SYMBOLOGY SETTINGS UPC Settings Code 39 Settings Codabar Settings Code 128 Settings I 2 of 5 Settings MSI/Plessy Settings
Page 13
SECTION C: UNIVERSAL OPTIONS Trigger Mode Beeper Operation Redundant Check Inter-Character Delay Inter-Message Delay
Page 17
SECTION D: MISCELLANEOUS SETTINGS Bar Code Length Settigns Block/Message Mode Block Mode Send Command Global Prefix / Suffix Bar Code Identifier
Page 19
APPENDICES Appendix A: Appendix B:
Code 39 Full ASCII Characters Factory Default Setting
Page 23 Page 27
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Part I General Information The LGZ Series Long Range CCD Scanners utilize state-of-the-art imaging similar to the technology found in digital cameras, facsimile machines and video camcorders. The scanner images the bar code label, then converts the digital signals into data the host computer can understand. By capturing the bar code image all at once, the scanner provides a fast, highly accurate read rate. Miniature surface mount electronics make up the CCD scanner's solid state construction. CCD scanners have no moving mechanical parts and provide years of trouble-free operation. This manual contains information on setting-up the scanner as well as programming various parameters of the scanner. LGZ scanner is available in several different interface configurations: Keyboard Wedge RS232 Serial Wand Emulation Laser Emulation The following sections contain information on setting up the various configurations
Unpacking Remove the scanner from its packaging and inspect it for damage. If the scanner was damaged in transit, call the dealer or distributor from whom you purchased it. If you purchased it directly from Opticon, call Opticon Customer Service Dept. at 800-636-0090.
Factory Technical Support If you have any questions or need assistance with programming your scanner call Opticon Technical Support at 800-6360090 please have the unit model number and several bar code labels readily at hand. The model number is located near the connector end of the cable. If the scanner must be returned, please contact Opticon to obtain an RMA (Return Merchandise Authorization) number prior to returning the product. The Customer Service Dept. may be reached at 800-636-0090. NOTE: Returned merchandise will not be accepted without a RMA number indicated clearly on the outside of the carton.
Page 4
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Keyboard Wedge Installation A "Y" connection cable is required for installation. The scanner is installed or "wedged" between the keyboard and the computer's CPU. Your “Y” cable should have connectors for both a PS2 and AT type installation. The "Y" cable connects both the scanner and the keyboard to the computer.
The scanner must match the type of computer being used. The default setting is for an IBM AT type computer. If this type does not match the host computer, refer to the “Computer Type Selection” in the programming section. If the cable connector does not match the type of cable required for your computer, remove the short cable section and insert it in the other leg of the Y cable so the correct connector matches your computer
RS232 Installation The RS-232 scanner cable is terminated in with a DB9 female connector. An external power supply is necessary to power the scanner. There is a power supply jack on the RS-232 connector. Installation is as follows: 1.
Plug the cable of the external power supply into the jack on the RS-232 connector.
2.
Plug the power supply into an electrical outlet (110 V AC)
3.
Turn on the power to the host computer. Make sure that the communication parameters of the computer are set to match those of the scanner. The default communications settings are: 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking
Wand Emulation Installation Plug the scanner into the decoder box or host device.
Laser Emulation Installation Plug the scanner into the host device.
Page 5
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Part II
Bar Code Menu Functions The programmable options are divided into four sections. Section A includes those options that are necessary to properly install the scanner and insure communications with the host computer. Options are provided for Keyboard Wedge, RS-232 and Wand Emulation operation. Section B contains the options that refer to the selection of specific bar code symbologies and options that are available for one or more symbologies. Section C includes the options that control the general operation of the scanner regardless of the interface or the symbologies selected. Section D includes miscellaneous commands and options that may be useful in some applications.
Section A Programming the Scanner This manual provides an easy way of changing certain parameters. A parameter is changed by reading a specific bar code associated with a specific function. To select menu options: 1.
Scan "Start Program Menu." The scanner will emit a loud two-tone beep to indicate that it is ready to be programmed.
2.
Scan the desired parameter selection from the menu (a two-tone beep and a green light indicate that the parameter has been accepted).
3.
Scan " End Program Menu." This completes the operation. The scanner exits the programming mode and the new parameter is saved in memory. It will not be lost even if power is removed from the scanner/
You can erase any parameter changes you have made and return the scanner to the previous setting by scanning the “Abort” programming bar code before you scan “End Program Menu”
%
NOTE: (
) A pointing finger indicates scanner default settings.
Page 6
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Reset All Defaults Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most applications, the scanner will work right out of the box without any need for additional programming. A list of the factory default settings is contained in Appendix B At any time you can return the scanner to the factory default settings by scanning the “Reset all Defaults” programming bar code below. You can erase any parameter changes you have made and return the scanner to the previous setting by scanning the “Abort” programming bar code before you scan “End Program Menu”
NOTE: (
Β
) A pointing finger indicates default settings throughout the following menus.
..
Start Program Menu
+//+
—
Reset all defaults
+..+
++
Abort
+,,+
+-
End Program Menu
+,.+
Β
Page 7
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Computer Type Selection (for Keyboard Wedge only) The keyboard Wedge interface scanner is designed to operate with an IBM personal computers and compatibles along with a Apple Macintosh PC's. Select the host computer type from the menu below.
NOTE: If the scanner has not been set to the correct host computer, the scanner will display random characters on the screen after reading a bar code label.
..
Start Program Menu
+//+
KE07
IBM 5530SC
+LF18+
KE05
IBM PC/XT
+LF16+
KE08
IBM 5530ZC
+LF19+
KE01
IBM AT & compatibles
+LF12+ ΒKE09
NEC 9801
+LF1:+
KE02
IBM PS-2 30-80
+LF13+
KE10
IBM 3160 Terminal
+LF21+
KE13
IBM PS-2 30/56
+LF2!+
KE12
MOS SYS
+LF23+
KE11
APPLE Mac II
+LF22+
KE14
IBM 3477 w/o break code
+LF25+
KE03
IBM 5550
+LF1!+
KE15
NEC 5200
+LF26+
KE04
IBM 5295 Terminal
+LF15+
+-
End Program Menu
+,.+
KE06
IBM 3472/77 Terminal
+LF17+
Page 8
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Keyboard Language Selection ..
Start Program Menu
+//+
KL01
USA
+LM12+
KL02
UK
+LM13+
KL03
German
+LM1!+
KL04
French
+LM15+
KL05
Spanish
+LM16+
KL06
Italian
+LM17+
KL07
Swiss
+LM18+
KL08
Swedish
+LM19+
Β
Message Terminator (for Keyboard Wedge only) DT01
None
+EU12+
DT02
Carriage Return
+EU13+
DT03
Horz. Tab
+EU1!+
DT04
Execute
+EU15+
+-
End Program Menu
+,.+
Β
Page 9
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
RS-232C Communication Parameters Handshaking Protocol Start Program Menu
+//+
HP01
None
+IQ12+
HP04
RTS/CTS
HP02 HP03
PB01
Even Parity
+QC12+
PB02
Odd Parity
+QC13+
+IQ15+
PB03
Mark No Parity
+QC1!+
ACK/NAK
+IQ13+
PB04
Space
+QC15+
Xon/Xoff
+IQ1!+
Β
Β
Message Terminator
Baud Rate
DT11
None
+EU22+
DT12
CR/LF
+EU23+
+CS1!+
DT13
CR
+EU2!+
2400
+CS15+
DT14
LF
+EU25+
BR05
1200
+CS16+
DT15
H Tab
+EU26+
BR06
600
+CS17+
DT16
STX/ETX
+EU27+
DT17
EOT
+EU28+
+-
End Program Menu
+,.+
BR01
19200
+CS12+
BR02
9600
+CS13+
BR03
4800
BR04
Β
Data Bits / Stop Bits / Parity DB07
7 Data Bits
+EC18+
DB08
8 Data Bits
+EC19+
SB01
1 Stop Bit
+TC12+
SB02
2 Stop Bits
+TC13+
Β
Β Β
Page 10
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
ACK/NAK Response Time Start Program Menu
+//+
RT01
300 mSec
+SU12+
RT02
2 Sec
+SU13+
RT03
500mSec
+SU1!+
RT04
3 Sec
+SU15+
RT05
1 Sec
+SU16+
RT06
5 Sec
+SU17+
+-
End Program Menu
+,.+
Β
Page 11
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Wand Emulation Speed Selection ..
Start Program Menu
+//+
WS04
High
+XT15+
WS01
Low
+TX12+
WS05
Higher
+XT16+
WS02
Medium
+XT13+
+-
End Program Menu
+,.+
WS03
Normal
+XT1!+
Β
Data Ouput Setting ..
Start Program Menu
+//+
WO01
Black = High
+XP12+
WO02
Black = Low
+XP13+
+-
End Program Menu
+,.+
Narrow / Wide Ratio ..
WS0 0 WS0 8 +-
Start Program Menu
+//+
1:2
+XT11+
1:3
+XT19+
End Program Menu
+,.+
Page 12
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Section B Symbology Selection The scanner autodiscriminates many bar code symbologies. However, if only one symbology is required, programming the scanner to read only that symbology will speed operation and eliminate read errors.
..
Start Program Menu
+//+
RC01
Enable Code 39
+SD12+
RD01
Disable Code 39
+SE12+
RC02
Enable Codabar
+SD13+
RD02
Disable Codabar
+SE13+
RC03
Enable UPC / EAN
+SD1!+
RD03
Disable UPC/EAN
+SE1!+
RCO4
Enable I 2of5
+SD15+
RD04
Disable I 2of5
+SE15+
RC06
Enable Code 128
+SD17+
RD06
Disable Code 128
+SE17+
Β Β Β Β
RC14
Enable MSI/Plessey
+SD25+
RD14
Disable MSI/Plessey
+SE25+
RC08
Enable Code 93
+SD19+
RD08
Disable Code 93
+SE19+
RC10
Enable EAN 128
+SD21+
RD10
Disable EAN128
+SE21+
RC09
Enable IATA
RD09
Disable IATA
+SE1:+
+-
End Program Menu
+,.+
Β
Β
+SD1:+
Β
Β
Page 13
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
UE27
Xmit UPC-A Leading Char
+VF38+
UE28
Do not xmit UPC-A Leading char
+VF39+
UE17
Xmit UPC-A Chk Digit "
+VF28+
UE18
Do not xmit UPC-A Chk Digit "
+VF29+
UE19
xmit UPC-E Leading Char
+VF2:+
+VF15+
UE20
Do not xmit UPC-E Leading Char
+VF31+
+VF16+
UE21
Xmit UPC-E Check Digit
+VF32+
+VF17+
UE22
Do not Xmit UPC-E Check Digit
+VF33+
+VF18+
UE25
Xmit EAN-13 Check digit
+VF36+
+VF19+
UE26
Do not Xmit EAN-13 Check digit
+VF37+
UE23
Xmit EAN-8 Check Digit
+VF3!+
+VF21+
UE24
Do not Xmit EAN-8 Check Digit
+VF35+
+VF22+
RD11
Convert to ISBN/ISNN
+SE22+
+VF23+
DC11
Do not Convert to ISBN
+SD22+
+-
End Program Menu
+,.+
Setting Options for UPC-A and UPC E bar codes .. UE01
Start Program Menu All Formats
UE02
EAN-8 or EAN13
UE03
UPC-A and EAN-13
UE04
UPC-A and UPC-E
UE05 UE06 UE07
UPC-A
UPC-E
EAN-13
+//+ +VF12+
Β
+VF13+ +VF1!+
UE08
EAN-8
UE09
No add-ons
UE10
5 Char Add-On
UE11
2 Char Add-On
UE12
2 or 5 Char Add-On
UE13
UPC-E as UPC-A
+VF2!+
UE14
UPC-E not as UPC-A
+VF25+
UE15
UPC-A as EAN-13
+VF26+
UE16
UPC-A not as EAN-13
+VF27+
+VF1:+
Β
Β Β Β Β Β Β
Β
Β Β Page 14
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Code 39 Settings
Codabar Settings
..
Start Program Menu
+//+
3901
Std code 39
+!:12+
3902
Full ASCII Code 39
+!:13+
CB06
3903
Xmit start/stop char
+!:1!+
CB07
3904
Do not Xmit start/stop char
+!:15+
3905
Calc & xmit Chk digit
+!:16+
3906
Calc, not xmit chk digit
+!:17+
3907
Do not calculate chk digit
+!:18+
3910
Enable concatenation
+!:21+
3911
Disable concatenation
+!:22+
..
Β
Β
CB05
CB08
CB12
Β
CB11 +-
Start Program Menu Do not xmit start/stop chars. Xmit start/stop as A,B,C,D Xmit start/stop as DC1~DC4 Xmit start/stop as a/t,b/n,c/*, d/e Enable Concatenation Disable Concatenation End Program Menu
+//+ +DC16+ +DC17+
Β
+DC18+ +DC19+ +DC23+ +DC22+
Β
+,.+
Β
Page 15
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Code 128 Parameters ..
Start Program Menu
+//+
1801
Enable FNC2 concatenation
+2912+
1802
Disable FNC2 concatenation
+2913+
1803
Do not calculate chk digit
Β
+291!+
1804
Calculate & xmit chk digit
1805
Calculate do not xmit chk digit
+2916+
1810
xmit FNC1 Char.
+2921+
1811
Do not xmit FNC1 Char.
+2922+
End Program Menu
+,.+
+-
2 of 5 Settings
+2915+
..
Start Program Menu
+//+
IT03
No chk digiit
+JU1!+
IT04
Β
IT05 +-
Calculate & xmit chk digit Calculate. Do not xmit chk digit End Program menu
Β
+JU15+ +JU16+ +,.+
Β MSI/Plessey Settings .. MS0 5 MS0 6 MS0 7 MS0 8 MA0 3 MA0 4 MA0 5 +-
Start Program Menu Calc chk digit 1 & xmit Calc & xmit both Calc. Do not xmit single chk digit Calc. & xmit single chk digit
+//+ +NT16+ +NT17+ +NT18+ +NT19+
Do not calc chk digit
+NB1!+
Calc & xmit chk digit
+NB15+
Calc. Do not xmit chk digit End Program menu
Β
+NB16+ +,.+
Page 16
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Section C: Universal Selections Trigger Mode Options
..
Start Program Menu
+//+
SM01
LEDs Off after xmit
+TN12+
SM02
LEDs On
+TN13+
SM04
Continuous Slow
+TN15+
+-
End Program Menu
+,.+
..
Start Program Menu
+//+
CP07
Enable
+DQ18+
CP08
Disable
+DQ19+
+-
End Program Menu
+,.+
Β
Data Redundant Check
Β
Page 18
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Intercharacter Delay The scanner may send data faster than the computer or application program can accept. This is called "keyboard buffer overrun". If data appears to be missing, random read errors occur or the scanner locks up and will not scan, experiment with the various keyboard timing options listed in the menu to follow.
..
Start Program Menu
+//+
IC01
No Delay
+JD12+
IC02
10 ms delay
+JD13+
IC03
20 ms delay
+JD1!+
IC04
50 ms delay
+JD15+
+-
End Program Menu
+,.+
Β
+
Inter-Message Delay You can add a delay between two consecutive messages. This delay is added before each data transmission.
..
Start Program Menu
+//+
IM01
No Delay
+JN12+
IM02
100 ms delay
+JN13+
IM03
500 ms delay
+JN1!+
+-
End Program Menu
+,.+
Β
Page 19
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Section D: Miscelaneous Setting Bar Code Length Options The minimum and/or maximum length of a bar code symbol can be set. For example, to set the minimum length, Scan Start Program Menu, scan the minimum bar code, scan a bar code of the desired minimum length, then scan End Program Menu.
..
Start Program Menu
+//+
3908
Code 39 Max Length
+!:19+
3909
Code 39 Min length
+!:1:+
9301
Code 93 Max Length
+:!12+
9302
Code 93 Min Length
+:!13+
1806
Code 128 Max Length
+2917+
1807
Code 128 Min Length
+2918+
SET
Code 128 Exact Length
+TFU+
CB09
Codabar Max Length
+DC1:+
CB10
Codabar Min Length
+DC21+
+-
End Program Menu
+,.+
*
Page 20
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Message/Block Mode Option (Code 39 only) This option allows you to treat scanned data as an independent Message or as a Block Message. In the Message mode, the data is transmitted immediately. In Block mode, data is added to a buffer and will be transmitted only after a Send command is scanned.
..
Start Program Menu
+//+
MB01
Message
+NC12+
MB02
Block
+NC13+
SET
Set Send Command
+TFU+
SC01
Enable Send command
+TD12+
+-
End Program Menu
+,.+
SC02
Β
SC03
Disable Send Command Store Send Command
+TD13+
Β
+TD1!+
Beeper Options
..
Start Program Menu
+//+
GR01
Beeper On
+HS12+
GR12
GR05
Beeper Off
+HS16+
GR13
GR10
Long Beep 120 ms
+HS21+
+-
Β
GR11
Medium Beep 50 ms Short Beep 20 ms Very Short 5 ms End Program Menu
+HS22+ +HS23+ +HS2!+ +,.+
Page 21
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Global Prefix and Suffix Options Adds a prefix and/or suffix to all symbologies. The total number of characters (sum of prefix and suffix) cannot exceed 10 characters. Enable “Full ASCII Code 39 option before you begin. Scan the Add Prefix or Add Suffix bar code. Then scan the characters you want to add from the ASCII bar code table in the Appendix A. Scan Set to store the prefix/suffix in memory.
..
Start Program Menu
+//+
HT01
Prefix
+IU12+
HT02
Suffix
+IU13+
SET
Set
+TFU+
+-
End Program Menu
+,.+
Page 22
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Bar Code Identifier The Keyboard Wedge and RS232 versions of this scanner allow you to establish and transmit a code that identifies the type of symbology scanned. The Code Identifier can be a maximum of two characters in length. For example, “39” can be established as the Code Identifier for a Code 39 bar code label. This Code Identifier can be transmitted whenever a Code 39 bar code is decoded. The factory default Code Identifiers are listed in Appendix B.
..
Start Program Menu
+//+
IS01
Enable
+JT12+
IS00
Disable
+JT11+
+-
End Program Menu
+,.+
Β
Create the Code Identifier as follows: (1) Scan the Start Program Menu programming bar code. (2) Scan the bar code below representing the symbology for which you wish to establish a Code Identifier. (3) Scan the programming bar code from the ASCII tablein Appendix A that represent the Code Identifier you wish to use. Example: to establish “AB” as the Identifier Code, scan the programming code “A” then the code “B”. (4) Scan the Set programming bar code (5) Scan the End Programming Menu bar code
..
Start Program Menu
+//+
CI01
Code 39
+DJ12+
CI04
UPC-E
+DJ15+
CI09
Code 128
+DJ1:+
CI05
UPC-A
+DJ16+
CI10
Code 93
+DJ21+
CI06
EAN-13
+DJ17+
CI11
MSI
+DJ22+
CI07
EAN-8
+DJ18+
SET
Set
+TFU+
CI02
I 2 of 5
+DJ13+
+-
End Program Menu
+,.+
CI08
Codabar
+DJ19+
Page 23
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Appendix A: Code 39 Full ASCII Settings
..
Start Program Menu
+//+
$P
DLE 5 (num)
+%Q+
%U
NUL
+&V+
$Q
DC1 (F1)
+%R+
$A
SOH (Insert)
+%B+
$R
DC2 (F2)
+%S+
$B
STX (Delete)
+%C+
$S
DC3 (F3)
+%T+
$C
ETX (Home)
+%D+
$T
DC4 (F4)
+%U+
$D
EOT (End)
+%E+
$U
NAK
+%V+
$E
ENQ (Up)
+%F+
$V
SYN (F6)
+%W+
$F
ACK (down)
+%G+
$W
ETB (F7)
+%X+
$G
BEL (left)
+%H+
$X
CAN (F8)
+%Y+
$H
BS (Backspace)
+%I+
$Z
SUB (F10)
+%[+
$I
HT (Tab)
+%J+
%A
ESC (F11)
+&B+
$J
LF (enter num)
+%K+
%B
FS (F12)
+&C+
$K
VT (right)
+%L+
%C
GS (ESC)
+&D+
$L
FF (page up)
+%M+
%D
RS (CTRL L)
+&E+
$M
CR (enter)
+%N+
+-
$N
SO page down
+%O+
..
$O
SI (Shift)
+%P+
/space
End Program Menu Start Program Menu SP
+,.+ +//+ +0!+ Page 24
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
/A
!
+0B+
3
3
+!+
/B
“
+0C+
4
4
+5+
/C
#
+0D+
5
5
+6+
/D
$
+0E+
6
6
+7+
/E
%
+0F+
7
7
+8+
/F
&
+0G+
8
8
+9+
/G
,
+0H+
9
9
+:+
/H
(
+0I+
/Z
:
+0[+
/I
)
+0J+
%F
:
+&G+
/J
*
+0K+
%G
<
+6H+
/K
+
+0L+
%H
=
+6I+
/L
‘
+0M+
%I
>
+6J+
-
-
+.+
%J
?
+6K+
.
.
+/+
%V
@
+6W+
/
/
+0+
0
0
+1+
+-
1
1
+2+
..
2
1
+3+
A
End Program Menu Start Program Menu A
+,.+ +//+ +B+
Page 25
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
B
B
+C+
T
T
+U+
C
C
+D+
U
U
+V+
D
D
+E+
V
V
+W+
E
E
+F+
W
W
+X+
F
F
+G+
X
X
+Y+
G
G
+H+
Y
Y
+Z+
H
H
+I+
Z
Z
+[+
I
I
+J+
%K
[
+6L+
J
J
+K+
%L
\
+&M+
K
K
+L+
%M
]
+&N+
L
L
+M+
5N
^
+&O+
M
M
+N+
%O
-
+&P+
N
N
+O+
%W
O
O
+P+
+A
a
+,B+
P
P
+Q+
+B
b
+,C+
Q
Q
+R+
+-
R
R
+S+
..
S
S
+T+
+C
+&X+
End Program Menu Start Program Menu c
+,.+ +//+ +,D+
Page 26
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
+D
d
+,E+
+R
r
+,S+
+E
e
+,F+
+S
s
+,T+
+F
f
+,G+
+T
t
+,U+
+G
g
+,H+
+U
u
+,V+
+H
h
+,I+
+V
v
+,W+
+I
i
+,J+
+Y
y
+,Z+
+J
j
+,K+
+Z
z
+,[+
+K
k
+,L+
%P
{
+&Q+
+L
l
+,M+
%R
}
+&S+
+M
m
+,N+
%Q
|
+&R+
+N
n
+,O+
%S
~
+&T+
+O
o
+,P+
%T
DEL
+&U+
+P
p
+,Q+
+-
End Program Menu
+,.+
+Q
q
+,R+
Page 27
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Appendix B: Default Settings The following tables lists the factory defaults settings. When the “Reset all defaults” programming code is scanned, the scanner will return to these parameters.
General Default Settings Parameter Symbologies Selected Code 39 UPC/EAN/JAN Code 128 I 2 of 5 Code 128 Code 93 EAN-128 Codabar IATA MSI Code 39 Options Start/Stop Characters Check Digit Concatenation UPC/EAN/JAN Options Formats Add-on UPC-E as UPC-A UPC-A/E Leading Digit UPC-A/E Check Digit Interleaved 2 of 5 No. of characters Check Digit Codabar Start/Stop Characters No of characters Code 128 Check Digit FNC 2 append MSI Check Digit No. of characters Code Identifier Transmit Code Identifier Code 39 I 2of 5 UPC-E UPC-A EAN-13 EAN-8
Default Setting Enabled Enabled Enabled Enabled Enabled Enabled Disabled Enabled Enabled Disabled
Transmit Disabled Off All Disabled Disabled Transmit Transmit 6 – 32 chars. Disabled A,B,C,D 6 – 32 chars.
Codabar Code 128 Code 93 MSI
N K L P
Scanning mode Prefix and Suffix Inter-Message delay Inter-Character delay Beeper on time
Trigger on None Normal Normal 50 mSec
Keyboard Wedge Default Settings Computer type IBM PC/AT US Message terminator Carriage return RS232 Default Settings Handshaking ACK/NAK response time Baud rate Data bit Stop bit Parity Message terminator
None 300 mSec 9600 8 1 None CR/LF
Wand Emulation Default Settings Speed Normal Output Black = High
Disabled Disabled Transmit Variable
Disabled M I E A F FF
Page 28
Manual No. 25-LGZ01-01
Series LGZ Long Range Handheld CCD Scanner
Manual for Long Range Scanner
Addendum/changes to LGZ Long Range Manual June 29 2001
Added commands to convert UPC/EAN to ISBN/ISSN
Nov 15 2001
Increased quiet zones on all programming bar codes. Corrected description of Trigger Modes.
Page 29