Transcript
Loop Test Translators Dual Channel • • • • • •
Ka and Ku Bands Synthesised LO Simultaneous Operation Local and Remote Ethernet Control Extremely Versatile Standard and Custom Options
The ALD series of Ka and Ku Band Loop Test Translators feature dual channel operation with the ability to introduce different transfer characteristics in each channel. In this way, one LTT instrument can be used in a variety of test applications for frequency conversions from Uplink (Tx) to Downlink (Rx) or to L-Band and from L-Band to Downlink (Rx). Each channel may have different values of Conversion Gain, Attenuation Range, Filtering Characteristics and LO Frequency. Instruments are essentially customised for the desired applications parameters.
General Specifications Maximum Input Level Conversion Gain Flatness
+10dBm +/-2dB typ. +/-0.5dB/40MHz max. Impedance 50 ohms Input VSWR 1.3:1 typ. Output VSWR 1.3:1 typ. Signal Related Spurious -25dBc typ. LO Related Spurious & Harmonics -30dBm typ. Non Signal or LO Related Spurious -60dBc min. Input Power 80-240V, 50-60Hz Input Power Connector IEC with Fuse Operating Temperature 0 to +50C (see options) Storage Temperature -10 to +70C Lock Alarm LED, Front Panel & Ethernet Input connector (see options) 2.92mm Female Ka Band SMA Female Ku Band Output Connector SMA Female Reference Input Connector BNC Female Ethernet Connector RJ45 Size 19” x 2U x 13.5” (343mm) incl. connectors & protrusions
Options: -00 Standard -01 Specific Programmed Frequency Steps -02 Switchable Internal 10MHz OCXO Reference Frequency Stability +/-0.05ppm over 0 to +50C +/-0.1ppm per year -03 Switchable Internal 10MHz OCXO Reference Frequency Stability +/-0.005ppm over 0 to +50C +/-0.02ppm per year +/-0.05ppm all causes in 2 years -04 60dB Attenuation Range -05 1.0dB Attenuation Steps -06 Input/Output filters for 60dB Isolation -07 LO Filter for 60dB LO Rejection -09 Internal Amplifier for 0dB nom. Conversion Gain -10 Dual Redundant Power Supplies – Diode Controlled -12 Waveguide RF Input -13 RS422/485 Frequency Control -14 Outdoor Weatherproof Housing (-20 to +70C) -15 Special Custom Options
LO Phase Noise (dBc/Hz) typical Offset Frequency (Hz) 100 1K 10K 100K 1M
2.0 -80 -90 -95 -95 -120
LO Frequency (GHz) 10.0 12.0 27.0 -70 -65 -60 -85 -75 -70 -90 -80 -75 -90 -80 -80 -115 -115 -110
Typical Configurations Model No
Direction
ALD-Ka-1001
Input Frequency Range (GHz)
Output Frequency Range (GHz)
Channel 1 27.5-31.50 0.95-1.70 Channel 2 0.95-1.70 17.70-21.20 ALD-Ku-1002 Channel 1 12.75-14.50 0.95-1.70 Channel 2 0.95-1.70 10.70-12.75 For a specific frequency plan, please advise the required input and output frequency ranges for each path.
LO Frequency Range (GHz) 26.55-29.80 16.75-19.50 11.80-13.05 9.75-11.05
We reserve the right to change standard product specifications without notice but will be pleased to consider control drawings for quotation.
Tel. +44 (0) 1376 550220 Fax. +44 (0) 1376 552145 Email:
[email protected] www.atlantecrf.com 40A Springwood Drive, Braintree, Essex CM7 2YN, England