Transcript
LOSS PREVENTION CERTIFICATION BOARD
RED BOOK 2011 Volume 2 LIST OF APPROVED PRODUCTS AND SERVICES - PASSIVE FIRE PROTECTION PRODUCTS & SERVICES - SECURITY PROTECTION SYSTEMS - RELATED INSTALLERS THIS VOLUME ALSO INCLUDES: - MANAGEMENT SYSTEMS - CONSTRUCTION PRODUCTS
A Specifier’s Guide
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT SYSTEMS AND ENVIRONMENTAL Foreword by Peter Holland CBE OStJ QFSM, President of the Chief Fire Officers Association and Chief Fire Officer of Lancashire Fire and Rescue Service Dear Specifier Continuing economic uncertainty makes us all aware of the need for protection against unexpected risks. In the life of any building, infrastructure or industrial facility, designers must increasingly consider business risk, especially potential exposure to the ‘unexpected’ such as fire or attack on security and security systems failure. By considering carefully what they specify, designers can mitigate these risks and demonstrate due diligence and engineering assurance whilst helping to prevent business losses. Business losses, whether caused by fire or security failure, can be large and disruptive; either is bad for publicity. And, although it is impossible to foresee all eventualities, by specifying effective, properly installed fire and security protection systems, the negative consequences of an incident can be reduced considerably. One of the best ways of doing this is to select products, systems and installers that are approved and listed by an independent third party certification body such as LPCB. Third party approval is confirmation that these products, systems and their installers have met and continue to meet appropriate standards. Independent third party certification is the best and most trustworthy form of approval. As an independent certifier, LPCB has one of the most extensive fire and security testing laboratories in the world and its approvals are undertaken by a highly qualified team of expert scientists and engineers. LPCB develops standards with rigorous consultation and involvement of a wide range of stakeholders, including clients, insurers, manufacturers, public bodies and the emergency services. This all goes to make the LPCB certification mark a mark you can trust I have, therefore, no hesitation in recommending the products and services listed in the Red Book 2011 to you.
ii
20 Nov 2011
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT SYSTEMS AND ENVIRONMENTAL Introduction Welcome to the 2011 Edition of the “Red Book”, the LPCB List of Approved Fire & Security Products and Services. The Loss Prevention Certification Board (LPCB) is part of BRE Global and together with the listings, the LPCB mark signifies that products and services have been approved by LPCB. The Red Book is an essential reference for specifiers, regulators, designers and end users of these products and services - if it is listed here, you know it has been checked out by people you can trust. BRE Global is part of the BRE Group under the BRE Trust. It is an independent third party approvals body offering certification of fire, security and sustainability products and services to an international market. BRE Global - protecting people, property and the planet. The Red Book is divided into sections which list related groups of products and services such as suppression, security and so on. Each section also summarises the technical basis for the approval of each product or service. The Red Book should always be used in conjunction with rules, regulations and design specifications required by the relevant Authority. The 2011 edition of the Red Book comprises 2 Volumes: Volume 1:
Fire Detection and Alarm products & services Fire Suppression products & services Related Installers
Volume 2:
Passive fire protection products & services Security Protection systems Related Installers Management Systems Construction products
Listings are given in the name of the manufacturer or service provider, in alphabetical order. The Red Book is available free of charge in hard copy, CD and memory stick. It is also available on our website at www.redbooklive.com
. The website gives you the most up to date information on which products are approved and in the unlikely event of suppliers needing to recall products or services or suspend production will identify these. Red Book updates Product and services approval details are amended regularly. To ensure that you are using the most up to date information please refer to www.RedBookLive.com . What is Third Party Approval? Third party approval (or certification) is a conformity assessment process, carried out by a body that is independent of both supplier and customer organisations. It provides confirmation that products and services have met and will continue to meet the requirements of specified standards and other normative documents. Third party approval provides a safeguard as to the performance of a product or service. LPCB third party product approval schemes are quality assurance schemes and comprise initial type testing and technical evaluation, assessment and surveillance of the manufacturer’s quality system and production procedures, regular audit testing, labelling and listing. Similarly, LPCB schemes for suppliers of services (installers) are also quality assurance schemes comprising a technical assessment of a contractor’s capability, assessment and surveillance of the installer’s quality system and production procedures, regular inspection of completed installations and listing.
20 Nov 2011
iii
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT SYSTEMS AND ENVIRONMENTAL Benefits of Third Party Approval A frequent concern of stakeholders is in knowing whether a product will perform in accordance with the stated specifications. These concerns can involve such product attributes as safety, health or environmental impacts, durability, compatibility, suitability for intended purposes or for stated conditions, and other similar considerations. These issues can all be addressed through product approvals. For specifiers, regulators, insurers, manufacturers and installers, the benefits of an LPCB approval are: For specifiers and regulators:
Risk reduction - specifying LPCB approved products and services demonstrates due-diligence and best endeavour and mitigates against possible accusations of negligence. Avoidance of costly mistakes - you can trust LPCB approved products and services to conform each and every time. Time - using Red Book Live to search for and assess products and services can save you time.
For manufacturers and installers:
Increased global sales - LPCB approval is recognised and specified widely throughout the world. In some territories LPCB approval is a mandatory requirement. Added value of the product or service - LPCB approved products and services are recognised as providing added value given their ability to conform each and every time. Reduced liability - LPCB approved products and services demonstrate due-diligence which can reduce liability for both you and your customers.
The LPCB Mark is a Mark you can Trust. The Third Party Approval Process LPCB offers approvals to existing British, European, International and LPCB’s own Loss Prevention Standards (LPSs). LPCB’s LPS approval schemes for both products and services are essentially level 5 schemes, as described in ISO/IEC Guide 67, with the added requirement to have a quality system certificated to ISO 9001. The technical requirements of LPCB schemes are given in Loss Prevention Standards (LPSs). These documents are drafted by LPCB technical experts in conjunction with appropriate external experts. They are then peer reviewed by representatives from trade bodies, regulators, insurers, specifiers, manufacturers and other suppliers. Finally these documents are approved for use by the BRE Global Governing Body; the Body that oversees all of the certification activities of BRE Global including LPCB. On occasion, approval may be carried out to other international standards where this is appropriate to a particular territory. Product schemes comprise:
Initial type testing and evaluation of product, sampled by LPCB
Approval and surveillance of the manufacturer’s (or supplier’s) quality management system to ISO 9001 (if you have products in for testing at LPCB, it generally costs little or no more to achieve ISO 9001 certification).
Assessment and surveillance of the manufacturer’s (or supplier’s) factory production control system (FPC)
iv
20 Nov 2011
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT SYSTEMS AND ENVIRONMENTAL
Periodic audit testing of the product from either the factory or marketplace
Labelling or marking as appropriate.
Listing of the approved product (service) in the Red Book.
Installer schemes comprise:
Technical assessment of the installation contractor’s capability
Approval and surveillance of the contractor’s quality management system to ISO 9001 or assessment against the requirements of the relevant Loss Prevention Standard where ISO 9001 is not appropriate. (If you have applied for LPCB assessment of your services, it generally costs little or no more to achieve ISO 9001 certification).
Regular surveillance inspections of on-going installations
The issue of Certificates of Conformity to demonstrate compliance for each installation
Listing of the approved installer in the Red Book.
The LPCB Mark After approval of a product or service the manufacturer or service provider is allowed to place the LPCB certification mark, as shown below*, on the product, packaging and literature etc.
Where LPCB holds accreditation through the United Kingdom Accreditation Service (UKAS), the approved company is allowed to include the UKAS logo alongside the LPCB mark for certain applications e.g. promotional literature or material and stationery, as shown below.*
The LPCB scheme rules define how and where the marks can be used. The LPCB horseshoe is the mark you can trust and it is recognised in 45 countries around the world by regulators, specifiers, designers and end users.
20 Nov 2011
v
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT SYSTEMS AND ENVIRONMENTAL Full details of LPCB accreditation can be found on the UKAS website at www.ukas.com . The products listed in Part 5 - Construction Products are approved under our BRE Certification brand:-
Where management systems certification under a BRE Global accredited scheme is granted, the approved company is allowed to use the following mark on promotional literature or material and stationery
All schemes are based on product testing/assessment and regular auditing. European Directives For products to be placed on the European market, manufacturers must comply with the regulatory requirements of a number of European Directives. To demonstrate compliance with these Directives, a manufacturer must make a declaration, based on an evaluation of the product, and affix the relevant mark. For some products the manufacturer will need to use the services of a Notified Certification Body or Notified Test Laboratory to demonstrate that the evaluation of the product has been carried out in whole or in part by a body independent of the manufacturer. Other products can merely be marked on the basis of a self declaration of conformity by the manufacturer. The relevant mark shows that a product meets minimum regulatory standards of health and safety as laid down in the Directives. It is not a quality mark and does not necessarily relate to the functional performance of the product. BRE Global is a Notified Body for: The Construction Products Directive (CPD) Pressure Equipment Directive (PED) Marine Equipment Directive (MED)
Transportable Pressure Equipment Directive (TPED)
vi
20 Nov 2011
PASSIVE PRODUCTS & SERVICES, SECURITY, MANAGEMENT SYSTEMS AND ENVIRONMENTAL Where the services of a Notified Body is required in order for a manufacturer to affix a mark to a product, BRE Global can provide a comprehensive service. Other Approvals BRE Global carries out approvals of a number of other construction products and management systems under other approval brand names. The details of these schemes are given in the relevant introductory sections.
For Fire and Security Products and Services Trust the LPCB Mark
20 Nov 2011
vii
CONTENTS 1 Building products 1 SECTION 1 Approved installers of passive fire protection products 3 SECTION 1.1 LPS 1500 approved installer of fire resisting compartmentation system 4 SECTION 1.2 LPS 1531 approved installer of passive fire protection products 5 SECTION 2 Construction product systems (building envelope, roofing & partitions) 13 SECTION 2.1 LPS 1181 Series 14 SECTION 2.1.1 LPS 1181 lining materials 16 SECTION 2.1.2 LPS 1181-1 cladding products used for the external envelope of buildings 17 SECTION 2.1.3 LPS 1181-2 sandwich panels or built-up panel systems used internally in a building 36 SECTION 2.1.4 LPS 1181-3 (draft) cladding used in pod construction 41 SECTION 2.2 LPS 1208 composite construction elements 43 SECTION 2.3 LPS 1581 external cladding systems on a masonry substrate 65 SECTION 2.3.1 LPS 1581 external thermal insulated cladding (ETICS) on masonry substrates 66 SECTION 2.3.2 LPS 1581 rain screen cladding systems (RSC) on masonry substrates 69 SECTION 2.4 LPS 1582 external cladding systems supported by a structural steelwork frame 71 SECTION 2.4.1 LPS 1582 external thermal insulated cladding (ETICS) supported by a structural steel frame 72 SECTION 2.4.2 LPS 1582 rain screen cladding system (RSC) supported by a structural steel frame 75 SECTION 2.5 Roofing products 76 SECTION 2.5.1 Protection against fire from outside the building 77 SECTION 2.5.2 Protection against fire from inside the building 84 SECTION 2.6 Reaction to Fire (RTF) classifications for Materials and Products 85 SECTION 3 LPS 1132 wall & floor penetration and linear gap seals 86 SECTION 4 Structural steel fire protection 131 SECTION 4.1 LPS 1107 structural steel fire protection - board and cementitious coverings 132 SECTION 4.2 Structural steel fire protection - intumescent thin film coatings 155 SECTION 5 Protective covering materials & scaffold cladding 160 SECTION 5.1 LPS 1207 Protective covering materials 161 SECTION 5.1.1 LPS 1207 protective covering materials - sheeting 162 SECTION 5.1.2 LPS 1207 protective covering materials - pre-formed 172 SECTION 5.2 LPS 1215 scaffold cladding materials 173 SECTION 6 Cavity fire barriers 177 SECTION 7 LPS 1195 temporary buildings for use on construction sites 179 SECTION 8 Products assessed for use in surface and sub surface transport applications 180 SECTION 9 Fire Protected Timber Stairs 186 2 Fire doors and shutters (incorporating installer scheme for fire and security doors) 191 SECTION 1.1 Firebreak doors and shutters 193 SECTION 1.2 Lift landing doors 205 SECTION 2 Fire and security door installers 206 SECTION 3 Service and maintenance of doors 208 3 Smoke and fire ventilation systems 213 SECTION 1 Fire dampers 215 viii
20 Nov 2011
CONTENTS SECTION 2 Fire resistant ducts SECTION 3 Smoke curtains SECTION 4 Powered smoke and heat exhaust ventilation SECTION 5 Grease Filters used in Commercial Kitchen Extract Systems 4 Security protection products SECTION 1.1 Intruder detection equipment SECTION 1.2 Alarm transmission equipment and signalling systems SECTION 1.2.1 Alarm transmission equipment and systems SECTION 2 Safes, strongrooms and secure safe cabinets SECTION 2.1 Safes SECTION 2.2 Secure safe cabinets SECTION 2.3 Automatic teller machine (ATM) safes SECTION 2.4 Anti-bandit atm security devices SECTION 2.5 Deposit safes SECTION 2.6 Strongrooms SECTION 3 Secure office furniture SECTION 4 Secure enclosures SECTION 5 Physical security protection of buildings SECTION 5.1 High security doorsets SECTION 5.1.1 High security hinged doorsets with plain leaves SECTION 5.1.2 High security hinged doorsets with glazed leaves SECTION 5.1.3 High security hinged doorsets with other leaf designs SECTION 5.1.4 High security folding doorsets SECTION 5.2.1 Domestic doorsets approved to PAS 23-1 SECTION 5.2.2 Domestic doorsets approved to PAS 24-1 SECTION 5.3 High security windows SECTION 5.3.1 High security windows - external windows SECTION 5.3.2 High security windows - secondary glazing systems SECTION 5.3.3 Rooflights SECTION 5.4 Domestic security windows SECTION 5.5 Security grilles, blinds and barsets SECTION 5.6 Security shutters SECTION 5.7 Perforated security screens SECTION 5.8 Louvre vents SECTION 5.9 Garage doors SECTION 6 Access covers and hatches SECTION 7 Secure walling systems SECTION 8 Secure roofing systems SECTION 9 Perimeter security products SECTION 9.1 Security fencing SECTION 9.2 Security gates SECTION 9.3 Turnstiles SECTION 10 Vehicle security barrier SECTION 11 Gas cylinder security devices SECTION 12 Physical security devices for computers and other ict equipment SECTION 13 Database management for asset marking SECTION 14 Asset marking systems SECTION 15 'Theft resistant' electronic products SECTION 16 Letter plates and letter boxes (mail boxes) SECTION 17 Key safes 20 Nov 2011
230 238 239 244 245 247 248 249 252 253 260 263 264 265 266 267 268 287 290 291 412 418 420 421 423 425 426 427 430 431 434 444 449 450 452 454 460 471 473 475 490 492 493 494 497 501 503 506 508 510 ix
CONTENTS SECTION 18 Security glazing 5 Construction products SECTION 1 Anchors, connectors, fasteners and fixing systems SECTION 2 Drainage and plumbing systems SECTION 3 Flooring systems SECTION 4 Groundworks and foundation systems SECTION 5 Membranes SECTION 6 Pre-fabricated building systems SECTION 7 Building systems for dwellings SECTION 8 Trussed rafters (timber) SECTION 9 Thermal insulation systems SECTION 10 Wall and roof cladding systems SECTION 11 Walling, roofing and partition systems SECTION 12 Conservation of fuel and power 6 Management system certification SECTION 1 Quality systems SECTION 2 Environmental systems SECTION 3 Health & safety certification BS OHSAS 18001
x
511 513 515 516 517 519 520 522 525 528 529 531 534 536 537 539 625 629
20 Nov 2011
INDEX 2 2M KABLO SAN. ve TIC. A.S. 539 A A & F Sprinklers Limited 539 A M Profiles Limited 540 A Steadman & Son 17, 540 A.C. Plastic Industries Limited 540 A.M. Fire Systems Limited 540 Abbey Thermal Insulation Ltd 5 Abbot Fire Group Limited 540 AccentHansen 291, 541 Actionair 215, 541 AD Sprinkler Protection Limited 541 Advanced Air (UK) Limited 223 Advanced Electronics Limited 541 AEI Cables Limited 541 Alliance Valves and Piping Supplies Limited 'AVPS' 542 Alpine Fire Engineers Limited 542 Aluroll Limited 444, 452, 542 AMPAC Europe Limited 542 Ampac Security Products Limited 542 Andreu Barbera S.L. 193, 543 Ansul Incorporated 543 Anvil International Inc. 543 Apollo (Beijing) Fire Products Co Ltd 543 Apollo Fire Detectors Limited 544, 625 APW Fire Protection Limited 544 Aquacast (Fabrications) Limited 454 Arabian Thermal Aire Industries Company Ltd 224 ArcelorMittal Construction Belgium 43, 544 ArcelorMittal Construction Belgium NV 17, 544 Argus Fire Protection Company Limited 544, 629 Argus-Spectrum Co 545 Armstrong Priestley Limited 545 Ascot Doors Limited 194, 208, 294, 445, 545 Asgard Secure Steel Storage (a trading division of Flexiform Business Furniture Limited) 268 Ashvale Fire Services Limited 545 ASLR Fabrication Services Limited 545 ATOM KABLO SANAYI VE TICARET A.S. 546 Attenborough Doors Limited 194, 546 Automatic Fire Control Limited 546 Avert Fire (UK) Ltd 5 B Bahra Cables Company 546 Bailey & Mackey Limited 546 Bainbridge International Limited 162 Balmoral Sectional Tanks Limited 547 Bangkok Cable Co Limited 547 Bastion Security Installations Limited 269 BBC Fire Protection Limited 547 Beijing Siemens Cerberus Electronics Limited 547 Besseges Limited 547 Biamp Systems Corporation 548 Blue Shield Fire Protection Limited 548 Blyweert Beaufort Aluminium Limited 412 Bolton Gate Co. Limited 420, 548 Bond Engineering (Maintenance) Ltd 208
20 Nov 2011
Booth Industries Limited 548 BPI Visqueen - Greenock 162, 548 Bradbury Security 301, 412, 434, 498, 549 Braithwaite Engineers Limited 549 Brammall Inc. 549 Britannia Kitchen Ventilation Limited 549 British Gypsum 132 Britton Merlin Limited 162 Brucha Ges.m.b.H 18, 36 Bryen & Langley Limited 5 BSB Engineering Services Limited 224, 549 BT Redcare 249 Burton Safes Limited 550 Bush (Fire Engineering) Limited 550 C C W Fields and Son Limited 321, 413 CA Group Limited 18, 550 Cavicel SpA 550 Ceodeux - Firetec 550 Chaoyi Industry Development 551 Charter Sepcialist Security Limited 551 Checkmate Fire Solutions Ltd 6 Chemring Energetics Limited 551 Chubb Fire & Security Limited 551 Circum Limited 552 Clark Door Limited 194, 206, 552 CLD Fencing Systems 475, 490, 552 Clearway Environmental Services (UK) Limited 323, 552 Cleshar Contract Services Ltd 6 Clymac Limited 552 Compco Fire Systems Limited 553 Computionics Limited (Trading as C-Tec) 553 Control Equipment Limited 553 Cooper Fulleon Limited 553 Cooper Lighting and Safety Limited 554 Cordek Limited 519 Core Industrial Plastics Limited 163, 554 Corecut Fire Protection (a division of Corecut Limited) 6 Corus Panels and Profiles 19, 554 Cranford Controls Limited 554 Crawford UK Limited 208, 209, 554 CTM Fire and Security Limited (Leyland & London Offices) 555 Culimeta-Saveguard Limited 177, 555 CVD Fire Protection Ltd 6 D D.I.S. Sprinklers 555 Daemon Fire and Security Limited 556 Dalen Limited 498, 556 Datatag ID Limited 501, 556 Dätwyler Cables 556 David Tyrrell T/A Nene Valley Acoustics 7 Day-Impex Limited 556 Debro Engineering and Presswork trading as Unistrut Ltd 557 Defensor Group Limited 557 Delta Extinctors S. A. 557
xi
INDEX Design & Supply Limited 324, 413, 557 Dewey Waters Limited 557 Digital Lighting (Dongguan) Co Ltd 558 Don & Low Ltd, Nonwovens 163 Doncaster Cables 558 Dong-A Flexible Metal Tubes Co. Ltd. 558 DoorTechnik 558 Draka UK Limited 558 Dryvit UK Limited 66, 72 DS SMITH CORREX (Trading as a division of DS Smith Plastics Limited) 163, 559 DST Group Ltd 86 Dubai Cable Company (Private) Limited, Trading as Ducab 559 Dudley Safes Limited 253, 260, 559 Duplus Architectural Systems Limited 559 DuPont de Nemours (Luxembourg) S.a.r.l. 520 E E&S Heating & Ventilation Ltd 7 Elta Fans Limited 239 EMCOR Facilities Services Limited, EMCOR Specialist Services 560 Emirates Fire Fighting Equipment Factory L.L.C. (FIREX) 560 Energy Control Systems Ltd 536 Envirowrap Solutions Limited 164, 173, 560 Essex Safety Glass Limited 512, 560 Eton Fire Limited 561 Eurobond Laminates Limited & Eurobond Doors Limited 20, 37, 44, 561 Eurobrick Systems Limited 531 Euroclad Limited 22, 51, 561 Euroform Products Limited 529 Everday Technology Co. Limited 562 Excel Industries Ltd 38, 562 Eyston Company Ltd 562 F F.V.S. Limited 562 Fendor Limited 7, 414, 426, 562 FES Limited, FES Sprinklers 563 FFE Fire & Security Limited 563 Fike Safety Technology Ltd 563 Filling and Packing Materials Manufacturing Company (F.I.P.C.O.) 563 Fire Alarm Solutions Limited 563 Fire Defence (Northern) Limited 564 Fire Defence plc 564 Fire Logistics Limited 564 Fire Protection Limited 7, 230, 564 Fire Protection Solutions Ltd 8 Fire Queen Limited 564 Fire Security (Sprinkler Installations) Limited 565 Fireproof Fire Engineering Limited 565 Firespray International Limited 231, 565 Firetecnics Systems Limited 565 First Fire Protection Limited 565 Flameshield Products Limited 233 Flameshield Products Limited (Incorporating Flameshield Limited) 8, 566
xii
Flexiform Business Furniture Limited-incorporating Asgard Secure Steel Storage 566 Florprotec Limited 164 Fortress Doors N.I. Limited 566 Franklin Hodge Industries Ltd. 566 Frontier-Pitts Limited 492 Fusion Building Systems 525 G G & A Fire Protection Ltd 4, 8 Galglass Limited 566 Gaocheng General Foundry 567 Gardner & Co (Kent) Ltd 8 Giffen Group 9 Gilray Plant Limited 165, 173 Globe Fire Sprinkler Corporation 567 Gloucester Composites Limited 567 Godrej & Boyce Mfg. Co. Ltd. (Security Equipment Division) 254, 260 Godwin Pumps Limited 567 Goran Plastics 165, 567 Gordonson Fire Protection Limited 568 Grange Door Systems 206, 209, 568 Grundfos Fire Systems 568 gte Brandschutz AG 195, 568 Gulf Security Technology Co. Ltd - A UTC Fire & Security Company 568 Gunfire (Gunite Eastern Limited) 9 Guthrie Douglas Limited 569 GW Sprinkler A/S 569 H H S Jackson & Son (Fencing) Limited, t/a Jacksons Fencing 476, 569 H&S Decorating Specialists Ltd 9 Haes Systems Limited 570 Hall & Kay Fire Engineering (Manchester) 570 Hall & Kay Fire Engineering (Paisley) 570 Hall & Kay Fire Engineering (Thame) 570 Hall & Kay Fire Engineering (West Midlands) 570 Hall Fire Protection Limited 571 Hallmark Fire (a division of SFS Fire Services Ltd) 571 Halton Foodservice Limited 244, 571 Handan Boate Foundry Co Limited 571 Hart Door Systems 196, 206, 571 Harvel Plastics Incorporated (Bakersfield) 572 Harvel Plastics Incorporated (Easton) 572 Hemsec Manufacturing Limited 23, 52, 572 Henry Lewis and Sons (Wireworkers) Limited 434, 572 Heras U.K. Fencing Systems 478, 572 Hersey Meters 573 Hershey Valve Co Limited 573 Hillmoore Fire Protection Ltd 9 Hilti (Gt Britain) Limited 573 Hilti Aktiengesellschaft 86 Hochiki America Corporation 573 Hochiki Corporation 573 Hochiki Europe (UK) Limited 574, 625 Honeywell Life Safety Systems UK 574 Honeywell Security UK Limited 574
20 Nov 2011
INDEX Horing LIH Industrial Co Ltd 574 Hörmann KG Freisen 196 Hosiden Besson Limited 575 Huzhou Jiusheng Electric Co Ltd 575 I Iceberg Building Services Limited 575 Icopal Limited 77, 165, 174 Icopal S. A. 471, 575 IKO PLC 79 Industrial Door Engineering Limited 197, 206, 209, 575 Industrial Textiles & Plastics Ltd 166, 174, 520 Influx Measurements Limited 576 Intelligent Engineering (UK) Ltd 517 IPB N.V. 166, 576 IR Martin Roberts, IR Security & Safety Limited 326, 421, 423 Irish Driver-Harris Company Limited 576 Irish Industrial Tanks Limited 576 Irish Sprinkler & Fire Protection Limited 576 ISOCAB France S.A. 24, 53 Isoclad Limited 54, 270, 460, 577 J J & J Design Limited 577 J Durrance & Co Ltd 198, 577 J W Singer 625 J. Bryceland Fire Systems Ltd 577 Jeld-Wen UK Ltd 186 John Brash & Company Ltd 531 K K.P.F.P. Limited 578 KAC Alarm Company Limited 578 Kean Building & Fire Protection Services Limited 578 Kentallen Fire Protection Limited 578 Kentec Electronics Limited 578 Key Housing Limited 525 Keystone Electric Wire & Cable Company Limited 579 Kidde Products Ltd, trading as AirSense Technology 579 Kingfell Plc 579 Kingspan Door Components S.A. 579 Kingspan Insulation Limited 24, 580 Kingspan Limited (t/a Profiles and Sections) 522, 534 Kingspan Ltd 25, 56, 580, 626, 629 Kingspan Ltd trading as Kingspan Structural, Kingspan Fabrications, Kingspan Controlled Environments (KCE), Kingspan Profiles and Sections 580, 626, 629 Kingspan Ltd. 27, 57, 580, 626, 630 KingspanTarec Industrial Insulation Limited 581, 626 Klober Limited 521 KME Italy SpA 581 Kone PLC 206, 210 L L.B.S. Group (incorporating L.B.S Security Services Limited - t/a Specialized Door
20 Nov 2011
Services, Russell Shutters, Olsen Shutters and Ranford Doors) 198, 210, 581 Landskroon B.V. 166, 175 Liddle Doors Limited 275, 328, 415, 435, 495, 581 Lincs Doors Limited 198, 581 Lingjack Engineering Works PTE Ltd 582 Linkester Fire Protection Limited 582 Lion Steelworks SDN. BHD. 257, 582 Lixil Nittan Company Limited 582 Lixil Nittan Electronic Company Limited 582 Logix UK Limited (Simplipac) 534 Lowrey Contractors Limited 275, 331, 418, 436, 465, 583 LPG Tecnicas en Extincion de Incendios, S.L. 583 Lubrizol Advanced Materials Europe B.V.B.A 583 M M & P Fire Solutions Ltd 584 M J Quinn Integrated Services Ltd 10 M. J. Quinn Integrated Services Limited 584 Mansell Construction Services LTD 10 Map Ventilation Limited 10 Marmorit (UK) GmbH 532 Mavili Elektronik Ticaret Ve Sanayi A.S. 584 Max Frank Limited 515 McAvoy Group Limited 179, 584 MCT Brattberg AB 120, 180 MECE Fire & Security Limited 585 Mercian Shutters Limited 199, 207, 210, 585 Mercury Engineering 585 Metsec Limited 522 Midas Technologies (GB) Limited 455, 585 Middle East Insulation 199 Midland Door Services Limited 585 Midlands Fire Ltd 10 MITIE McCartney Fire Protection Limited 586 MITIE Property Services Limited - Midlands 4 MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems) 586 Mitsubishi Plastics Inc 586 Modgal Metal (99) Limited 587 Modular Panel Systems Limited 28, 57 Monarflex 167, 587 Morgan Marine Limited 277, 587 Morley-IAS Fire Systems By Honeywell 587 MultiSteel Limited 415, 467 N N.V. Joris IDE 29, 588 Nanjing Fire Protection Technology Co Limited 588 National Fire Fighting Manufacturing Company Limited (NAFFCO) 588 National Sprinkler Company Limited 588 Nexans Turkiye Endustri ve Ticaret A.S. 589 NIBCO Inc 589 Nields Plastic Company Limited 167, 589 Nitin Fire Protection Industries Limited 589 Nittan (UK) Limited 590 Nittan Fire Protection System (Zhongshan) Company, Limited 590 NK Fencing Limited 482 NMC (UK) Limited 590
xiii
INDEX No Climb Products Limited 590 Nobel Fire Systems 590 Northern Ireland Plastics Limited 167, 591 Notifier Fire Systems by Honeywell 591 Nu-Form Fire UK Limited 591 O Ockwells Limited 167, 172 Olympic Fire Protection Limited 591 O'Mahony Contractors Ltd 11 Ondaplast SpA 168 P P&M Group Ltd trading as ISD 4, 11 Pace Technology Co. Limited 591 Panel Projects Limited 58, 592 Paneltex Limited 38 Paroc Panel System Oy Ab 58, 592 Patterson Pump Ireland Limited 592 PEL Services Limited 592 Pendle Designs Limited 592 Peripheral Support Services Limited 593 Permanite Asphalt 83 PermaRock Products Limited 532 Pittway Tecnologica Srl. 593 Portakabin Ltd 41 Potter Electric Signal Company 593 Powershield Doors Limited 332, 593 Pressex UK Limited 264, 593 Prestige Fire Door Services Limited 207 PRO TEC Vinduer A/S 431 Professional Barrier Systems Limited279, 436, 594 Project Fire Products Limited (incorporating Project Fire Engineers) 594, 626 Promat UK Ltd 60, 132, 155 Protec Camerfield Limited 594 Protec Fire Detection plc 594 Protec International Limited 168, 172, 175, 595, 627 Protecta Screen Ltd 169 Provincial Sprinkler Co. Limited 595 Prysmian Cables & Systems Limited 595 Prysmian Cables & Systems Ltd 595 Prysmian Power Cables & Systems Australia Pty Limited 596 PSF Wales Limited 279, 339, 596 Pyrotherm Ltd 11 Q Qinhuangdao Taidy Flex-Tech Co. Ltd 596 Quinn Therm Limited 30, 596 R R & D Sheetmetal Limited 281, 340 R & S Fire & Security Services Limited 596 R Lewis & Co. (UK) Ltd 11 RAMCRO S.p.A 597 Rapidrop Global Limited 597 Recticel Insulation Products / Recticel N.V 30 Red Rose Fire Protection Limited 597 Reliable Fire Sprinkler Limited 597 Retainagroup Limited 501, 504, 598 RGB Integrated Services Limited 598 RGT Fire Protection Limited 598
xiv
Richmond Fire Engineers Limited 598 RMD Fire Control Limited 599 Robust UK Limited 599 Rockwool Limited 31, 67, 84, 85, 121, 152, 177, 181, 234, 599 Rolland Sprinklers 599 Ross Fire Protection Limited 599 Rotary Firematic Limited 600 Rotherham CNC Ltd 600 RSM Refko Installations Limited 600 Ruskin Air Management Limited 627 Ruukki Construction Oy 60 Ruukki Polska Sp. z.o.o 32 Ruukki Polska Sp. Z.o.o. 600 S S.F.S. FIRE SERVICES LIMITED (trading as Hall & Kay Fire Engineering and Chubb Fire Mechanical Division) 600 S.F.S. Fire Services Ltd, T/A Hall & Kay Fire Engineering 601 Safe Partnership 207, 211, 346, 601, 627 SafeGuard Doors, A Division of Adams Rite Europe Limited 346, 601 Safeguard Security, a trade name of WBH Industries 437, 601 Safety Hi-Tech Srl 601 Safety Technology International (Europe) Limited 602 Saint-Gobain Weber Limited 519 Salisbury Glass Centre Limited 422, 424, 432, 602 Sanwa Yoshida (JiaXing) Construction Material Industry Co., Ltd 602 SAPAG Industrial Valves 602 Saudi Factory For Fire Equipment Co. 200, 602 Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger, Southhampton) 603 Scotshield Limited 603 Sealed Air Limited 169 Security Blinds Limited 438, 603 Sekisui Aqua Systems Company Limited 603 Select Fire Services Limited 604 Selectaglaze Limited 427, 604 Selectamark Security Systems plc 502, 504, 604 Shaanxi J & R Fire Fighting Co Ltd 604 Shakun Polymers Limited 604 Shellcast Systems Limited 446, 605 ShenZhen CICAM Manufacturing Co Ltd 605 Shurjoint Metals Inc. 605 Siemens plc, Building Technologies, Fire Safety Division 605 Siemens Switzerland Limited, Building Technologies Division 606 SigNET AC Limited 606 Simbars (UK) Limited 439, 606 SIP Energy Ltd 526 SMP Security Limited 257, 261, 607 Solent Fire Protection Services Limited 607 Solicom SA 170, 175 Sotech Limited 69, 75, 607 Southern Grille & Gate Limited 607
20 Nov 2011
INDEX Spears Manufacturing Company Inc 607 Specialist Panels UK Limited 62, 608 SpeedDeck Building Systems Limited 32 SPIE Fire (A division of SPIE) 608 SPIE Matthew Hall 608 SPP Pumps Limited 609, 627 Sprue Safety Products Ltd 609 Stafford Bridge Doors Limited 347, 416, 450 Stanair Industrial Door Services Limited 211, 610 Stancold plc 62, 610 Static Systems Group Plc 610 Steeltech Systems Limited 610 Steelway Fensecure Limited t/a Steelway Brickhouse 456 STO AG 610 Sto Ltd 67, 73 Stobich Brandschutz GmbH 201 Stopfire Ltd 12 Stroma Contracting Ltd 12 Sunjüt A.S. 170, 176, 611 Sunray Engineering Limited 201, 207, 360, 417, 611 Superglass Insulation Limited 85 Supra UK Limited 611 Sure Lock Doors Limited 611 Surelock McGill Group 612 SuZhou Primetech Electronics Co Limited 612 SWS UK 439, 447, 449, 453, 612 System Sensor 612 System Sensor de México S.A. de C.V. 613 System Sensor Fire Detectors 613 System Sensor, Honeywell International (I) PVT. Limited 613 T Talentum Developments Limited 613 TangoRail Limited 484, 613 Taylor Fire Sprinklers Limited 614 Technocover Limited (incorporating TechnoRail and Strataform) 203, 282, 376, 419, 450, 458, 468, 496, 614, 628 Terofire Products 614 Thameside Fire Protection Co. Limited 614 The Blinking Lamp Company Ltd 170, 176 The Expanded Metal Company Limited 440, 469, 487, 490 The Reliable Automatic Sprinkler Co., Inc, 614 The Rooflight Company 430, 615 The Safety Letter Box Company Limited 508 The Viking Corporation 615 Thermal Engineering Contracts Ltd 12 Thermotech Fire Protection Limited 615 ThyssenKrupp Steel Europe AG 33 Tindall Engineering Limited 615
20 Nov 2011
Total Polyfilm Limited 171, 615 Tratos Cavi SpA 616 Trellicor (Pty) Limited 441, 449, 616 Trimetals Limited 286, 616 Trimo d.d 34, 39, 63 Twinplast Limited 171, 616 Tyco Building Services Products B.V. 616 Tyco Fire & Building Products 617 Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) 211, 212, 617 Tyco Fire Products Manufacturing Limited 619, 628 Tyco Flow Control (M) Sdn. Bhd. (Tyco Fire Suppression & Building Products, Malaysia) 619 Tyco Thermal Controls UK Ltd 619 U UK Fire Safety Limited 619 UK Firewatch Limited 620 Ultra Suppression Systems Limited 620 Univar Speciality Consumables 171 Universal Fixings Limited 620 UTC Fire & Security (Africa) trading as Ziton 620 UTC Fire & Security Americas Corporation, Inc. 621 UTC Fire & Security B.V. 510 UTC Fire & Security Services 621 V Ventcroft Limited 621 Victaulic Company 621, 622 Viking Plastics 622 Vimpex Limited 622 Vipond Fire Protection Limited 623 Visqueen Building Products 521 Vulcan Tanks Limited 623 W Wagner Group GmbH 623 Weber, Saint-Gobain Weber Limited 68 WebWayOne Ltd 250 Wienerberger Limited 533 WOPF Befestigungselemente GmbH 623 Wrexham Mineral Cables 623 Writech Industrial Services Limited 624 X Xi'an System Sensor Electronics Limited 624 Xtratherm Limited 34, 624 Xtratherm UK Limited 624, 628, 630 Y Yorkon Limited 41 Yorkshire Building Services (Whitwell) Limited 529 Z Zeta Alarm Systems by GLT Exports Limited 624 Z-Led Limited 533
xv
Part 1 BUILDING PRODUCTS
PART 1: BUILDING PRODUCTS INTRODUCTION The specification and installation of building products and systems that provide passive fire protection is a fundamental aspect of fire safety. Correctly specified and installed passive fire protection products and systems will deliver a building that resists the incidence of fire to best effect, and in turn provide safety for the occupants and firefighters, and will reduce the potential for property loss. In England and Wales, Building Regulations define requirements to ensure the health and safety of those who occupy or visit buildings. Guidance on how to comply with the Building Regulations in England and Wales is given in a series of Approved Documents. Approved Document B provides guidance in respect of fire safety. In other territories, other regulations will apply as laid down by the Authority Having Jurisdiction (AHJ). For Scotland, Building Regulations guidance is provided by the Domestic and Non-Domestic Technical Handbook and Northern Ireland Building Regulation guidance is provided by the Department of Finance (DFP) Technical Booklet E. Passive fire protection is a combination of design, assembly and material choice. This will include: Protection of structural elements Materials that do not contribute to fire growth Limited toxicity of combustion products Walls and floors that provide compartments to resist the spread of fire Provision of a building envelope to resist fire entering from outside In addition to careful design and product selection, it is recommended that all products are installed by LPCB approved contractors who have demonstrated their competence. Listings in this section include: Products - Partitions - Structural steel protection - Fire stopping/penetration seals - Products used in transport applications - Walls and roofs/roofing - the building envelope - Protective sheeting - Temporary buildings for use on site These products are approved in accordance with various standards, the details of which are given at the front of each section. Installation contractors Contractors are approved in accordance with: LPS 1500: Requirements for the approval and listing of companies installing construction elements used to provide compartmentation in buildings. LPS 1531: Requirements for the approval and listing of companies installing or applying passive fire protection products.
2
20 Nov 2011
PART 1: SECTION 1 APPROVED INSTALLERS OF PASSIVE FIRE PROTECTION PRODUCTS
A fundamental aspect of fire safety in buildings is the specification and installation of ‘built in’ or passive fire protection products and systems. It has long been recognised that the performance of a product can be severely undermined by poor installation or application leading to failure in the event of a fire. This has led to the recent development of LPS 1500 Requirements for the LPCB approval and listing of companies installing construction elements used to provide compartmentation in buildings and LPS 1531 Requirements for the approval and listing of companies installing or applying passive fire protection products. Both these schemes help to ensure that companies installing passive fire protection : · · · · ·
Have sufficient training and expertise to install the products or systems using the correct techniques. Use products where it can be demonstrated that they will meet the required fire performance. Have access to up to date installation instructions for the installed systems. Carry out and record in process inspection checks prior to, during and after the product or system installation. Issue LPCB Certificates of Conformity for each installation.
LPS 1500 was developed specifically for companies installing fire resisting compartmentation systems approved by the LPCB to LPS 1208. LPS 1531 is an installer scheme that covers all the major product areas of passive fire protection.
20 Nov 2011
3
PART 1: SECTION 1.1 LPS 1500 APPROVED INSTALLER OF FIRE RESISTING COMPARTMENTATION SYSTEM
The companies listed in this section are approved installers of fire resisting compartmentation systems approved by LPCB to LPS 1208. LPS 1208 Approved products for use in the following elements of construction may be installed under this scheme.
Loadbearing compartment walls and partitions Non-load bearing compartment walls and partitions External walls Curtain walls Cavity barriers Roofs where fire resistance is required (loadbearing and non-loadbearing) Loadbearing compartment floors Insulated panels used for enclosing production and storage areas in food factories.
G & A Fire Protection Ltd Helions Bumpstead Road, Haverhill, Suffolk CB9 7AA, United Kingdom Tel: +44 (0) 1440 714650 • Fax: +44 (0) 1440 713371 E-mail: [email protected] • Website: www.ga-group.com Certificate No. 889PIb to LPS 1500 Issue 2 Installer of fire resisting compartmentation systems to LPS 1500
MITIE Property Services Limited - Midlands 2 Colwick Quays Business Park, Private Road No.2, Colwick, Nottingham NG4 2JY, United Kingdom Tel: 0115 940 1770 • Fax: 0115 940 2232 E-mail: [email protected] • Website: www.mitie.com Northern Office MITIE Property Services Limited, Meiklewood Gate, 35 Meiklewood Road, Glasgow G51 4GB, United Kingdom E-mail: [email protected] • Website: www.mitie.com Certificate No. 769a to LPS 1500: Issue 2.0 Installer of Fire Resisting Compartmentation Systems to LPS 1500
P&M Group Ltd trading as ISD Unit A, 125 Business Park, Llanthony Road, Gloucester, Glos GL2 5JQ, United Kingdom Tel: +44 (0) 1452 520649 • Fax: +44 (0) 1452 301910 E-mail: [email protected] • Website: www.isdcoldstores.co.uk Certificate No. 1008PIa to LPS 1500 Issue 2.0 Installer of fire resisting compartmentation systems to LPS 1500
4
20 Nov 2011
PART 1: SECTION 1.2 LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS
The companies listed in this section are approved to install passive fire protection products for the Appendix areas indicated in their entry. Appendix areas: 1. Penetration, cavity barrier and linear gap seals 2. Fire rated board and cladding to structural elements 3. Intumescent coatings to structural elements 4. Fire rated spray materials 5. Fire rated ductwork systems 6. Fire resisting dampers 7. Fire resistant compartment wall systems 8. Offsite application of intumescent coatings to structural elements
Abbey Thermal Insulation Ltd 23-24 Riverside House, Lower Southend Road, Wickford, Essex SS11 8BB, United Kingdom Tel: +44 (0) 1268 572116 • Fax: +44 (0) 1268 572117 E-mail: [email protected] Certificate No. 1014PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barrier and linear gap seals. Appendix 2 - Fire rated board and cladding to structural elements. Appendix 5 - Fire rated ductwork systems.
Avert Fire (UK) Ltd P O Box 248, Dawes lane, Scunthorpe DN16 1DW, United Kingdom Tel: +44 (0)1724 853712 • Fax: +44 (0)1724 278848 E-mail: [email protected]; [email protected] • Website: www.avertfire.co.uk Certificate No. 850PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals.
Bryen & Langley Limited 48-60 Footscray Road, Eltham, London SE9 2SU, United Kingdom Tel: +44 (0)20 8850 7775 • Fax: +44 (0)20 8850 6772 E-mail: AEscudier@bryen-langley • Website: www.bryen-langley.com Certificate No. 897Pl to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals.
20 Nov 2011
5
PART 1: SECTION 1.2 LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS
Checkmate Fire Solutions Ltd Head Office: Royd House, 11 Birds Royd Lane, Brighouse, West Yorkshire HD6 1LQ, United Kingdom Tel: 01484 721154 • Fax: 01484 723152
Southern Office: Unit 1, Woodgates Farm, Woodgates End, Dunmow, Essex CM6 2BN, United Kingdom Tel: +44 (0)1279 850021 • Fax: +44 (0)1279 850261 E-mail: [email protected] • Website: www.checkmatefire.com Certificate No. 860PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals Appendix 2 - Fire rated board and cladding to structural elements Appendix 3 - Intumescent coatings to structural elements
Cleshar Contract Services Ltd Heather Park House, North Circular road, Stonebridge, London NW10 7NN, United Kingdom Tel: +44 (0) 20 8733 8888 • Fax: +44 (0) 20 8733 8899 E-mail: [email protected] / [email protected] • Website: www.cleshar.co.uk Certificate No. 944PI to LPS 1531 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals
Corecut Fire Protection (a division of Corecut Limited) Bankhead, Broxburn, West Lothian EH52 6PP, United Kingdom Tel: +44 (0) 1506 854710 • Fax: +44 (0) 1506 853068 E-mail: [email protected] • Website: www.corecut.co.uk Certificate No. 1028PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals. Appendix 3 - Intumescent coatings to structural elements.
CVD Fire Protection Ltd Unit 1A, East End Farm Estate, Lanark Road, Carstairs, Lanarkshire ML11 8QG, United Kingdom Tel: +44 (0) 845 450 1601 • Fax: +44 (0) 845 450 1602 E-mail: [email protected] • Website: www.cvdfire.co.uk Certificate No. 1009PI to LPS 1531 Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals
6
20 Nov 2011
PART 1: SECTION 1.2 LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS Appendix 2 - Fire rated board and cladding to structural elements Appendix 3 - Intumescent coatings to structural elements
David Tyrrell T/A Nene Valley Acoustics 2a New Street, Irthlingborough, Northamptonshire NN9 5UG, United Kingdom Tel: +44 (0) 1933 650650 • Fax: +44 (0) 1933 704830 E-mail: [email protected] Certificate No. 1021PI to LPS 1531 Issue 1 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barrier and linear gap seals.
E&S Heating & Ventilation Ltd Diplocks Way, Hailsham, East Sussex BN27 3JF, United Kingdom Tel: +44 (0) 1323 845492 • Fax: +44 (0) 1323 440577 E-mail: [email protected] • Website: www.esgroup.co.uk Certificate No. 1013PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 5 - Fire rated ductwork systems.
Fendor Limited Heworth House, William Street, Felling, Gateshead NE10 0JP, United Kingdom Tel: +44 (0)191 438 3222 • Fax: +44 (0)191 438 1686 E-mail: [email protected] • Website: www.fendor.co.uk Certificate No. 712c to LPS 1531 Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals.
Fire Protection Limited Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 231 E-mail: [email protected] • Website: www.fireprotection.co.uk Certificate No. 277b to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope: Appendix 5 - Fire rated ductwork systems.
20 Nov 2011
7
PART 1: SECTION 1.2 LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS
Fire Protection Solutions Ltd 1-3 Highway Point, 239 Torrington Avenue, Coventry CV4 9AP, United Kingdom Tel: +44 (0) 845 0538989 • Fax: +44 (0) 2476 465568 E-mail: [email protected] • Website: www.firecontractor.co.uk Certificate No. 1015PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barrier and linear gap seals. Appendix 2 - Fire rated board and cladding to structural elements. Appendix 3 - Intumescent coatings to structural elements.
Flameshield Products Limited (Incorporating Flameshield Limited) 4 The Limes, Ingatestone, Essex CM4 0BE, United Kingdom Tel: +44 (0)1277 352202 • Fax: +44 (0)1277 355419 E-mail: [email protected] • Website: www.flameshield.org Certificate No. 785b to LPS 1531 Issue 1 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 5 - Fire rated ductwork systems.
G & A Fire Protection Ltd Helions Bumpstead Road, Haverhill, Suffolk CB9 7AA, United Kingdom Tel: +44 (0) 1440 714650 • Fax: +44 (0) 1440 713371 E-mail: [email protected] • Website: www.ga-group.com Certificate No. 889PIa to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals Appendix 2 - Fire rated board and cladding to structural elements Appendix 3 - Intumesent coatings to structure elements
Gardner & Co (Kent) Ltd 1 - 5 Bermondsey Street, London SE1 2ER, United Kingdom Tel: 020 7403 5894 • Fax: 020 7378 0316 E-mail: [email protected] • Website: www.gardnerco.net Certificate No. 1040PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 5 - Fire rated ductwork systems.
8
20 Nov 2011
PART 1: SECTION 1.2 LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS
Giffen Group Lyon Way, St Albans, Hertforshire AL4 0LQ, United Kingdom Tel: +44 (0)1727 869126 E-mail: [email protected] • Website: www.giffengroup.co.uk Certificate No. 979PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity, barriers and linear gap seals.
Gunfire (Gunite Eastern Limited) Endeavour House, Compass Point, St Ives, Cambridgeshire PE27 5JL, United Kingdom Tel: +44 (0)1480 466880 • Fax: +44 (0)1480 308999 E-mail: [email protected] • Website: www.gunite.co.uk Certificate No. 848PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals. Appendix 3 - Intumescent coatings to structural elements.
H&S Decorating Specialists Ltd 1 Wellesley Avenue, Richings Park, Iver, Bucks SL0 9AU, United Kingdom Tel: +44 (0)1753 654123 • Fax: +44 (0)1753 654345 E-mail: [email protected] • Website: www.hsgroup.co.uk Certificate No. 956PI to LPS 1531 Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 3 - Intumescent coatings to structural elements
Hillmoore Fire Protection Ltd Unit 17-18 Woodlands Farm, Spring Lane, Cookham Dean, Berkshire SL6 9PN, United Kingdom Tel: +44 (0)1628 890122 • Fax: +44 (0)1628 478543 E-mail: info@ hillmoorefire.co.uk • Website: www.hillmoorefireprotection.co.uk Certificate No. 849PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barrier and linear gap seals. Appendix 7 - Fire resistanct compartment wall system.
20 Nov 2011
9
PART 1: SECTION 1.2 LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS
M J Quinn Integrated Services Ltd 119 Farringdon Road, London EC1R 3DA, United Kingdom Tel: 0207 239 8750 • Fax: 0207 239 8751 E-mail: [email protected] • Website: www.mjquinn.co.uk Certificate No. 1041PI to LPS 1531 Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barrier and linear gap seals.
Mansell Construction Services LTD Rink Road, Ryde, Isle of Wight PO33 1LP, United Kingdom Tel: +44 (0) 1983 563668 • Fax: +44 (0) 1983 615600 E-mail: [email protected] • Website: www.mansell.plc.uk Certificate No. 1017PI to LPS 1531 Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barrier and linear gap seals. Appendix 7 - Fire resistant compartment wall systems.
Map Ventilation Limited Hanwiz House, Milner Way, Ossett, Wakefield WF5 9JG, United Kingdom Tel: 01924 278175 • Fax: 01924 278126 E-mail: [email protected] • Website: www.mapventilation.co.uk Certificate No. 1065PI to LPS 1531 Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 5 - Fire rated ductwork systems
Midlands Fire Ltd Unit D8 The Ropewalk Industrial Estate, The Ropewalk, Ilkeston, Derbyshire DE7 5HX, United Kingdom Tel: +44( 0) 115 932 9548 • Fax: +44 (0) 845 009 5727 E-mail: [email protected] • Website: www.midlandsfire.co.uk Certificate No. 887PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope: Appendix 1 - Penetration, cavity barriers and linear gap seals Appendix 7 - Fire resistant compartment wall systems.
10
20 Nov 2011
PART 1: SECTION 1.2 LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS
O'Mahony Contractors Ltd 60 Middle Road, Higher Denham, Buckinghamshire UB9 5EQ, United Kingdom Tel: 01895 833553 • Fax: 01895 835003 E-mail: [email protected] • Website: www.omahonycontractors.com Certificate No. 914PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals Appendix 2 - Fire rated board and cladding to structural elements
P&M Group Ltd trading as ISD Unit A, 125 Business Park, Llanthony Road, Gloucester, Glos GL2 5JQ, United Kingdom Tel: +44 (0) 1452 520649 • Fax: +44 (0) 1452 301910 E-mail: [email protected] • Website: www.isdcoldstores.co.uk Certificate No. 1008PIb to LPS 1531 Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals. Appendix 2 - Fire rated board and cladding to structural elements. Appendix 7 - Fire resistant compartment wall systems.
Pyrotherm Ltd 8 Jensen Court, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1SQ, United Kingdom Tel: +44 (0)1928 565641 • Fax: +44 (0) 1928 565648 E-mail: [email protected] • Website: www.pyrotherm.co.uk Certificate No. 1007PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals. Appendix 2 - Fire rated board and cladding to structural elements. Appendix 3 - Intumescent coatings to structural elements.
R Lewis & Co. (UK) Ltd Unit 7 and 8, Parklands Industrial Estate, East Moors Road, Cardiff CF24 5JP, United Kingdom Tel: +44 (0) 2920 215716 • Fax: +44 (0) 2920 406205 E-mail: [email protected] • Website: www.rlewisandcoukltd.com Certificate No. 1006PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals. Appendix 2 - Fire rated board and cladding to structural elements. Appendix 3 - Intumescent coatings to structural elements.
20 Nov 2011
11
PART 1: SECTION 1.2 LPS 1531 APPROVED INSTALLER OF PASSIVE FIRE PROTECTION PRODUCTS
Stopfire Ltd Units 22, 23, 24 & 32 Dryden Road, Loanhead, Midlothian EH20 9LZ, United Kingdom Tel: +44(0)131 448 0555 • Fax: +44(0)131 448 0556 E-mail: [email protected] • Website: www.stopfireltd.com Certificate No. 862PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals Appendix 2 - Fire rated board and cladding to structural elements Appendix 3 - Intumescent coatings to structural elements
Stroma Contracting Ltd Stroma House, Unit 4, Pioneer Way, Castleford WF10 5QU, United Kingdom Tel: +44 (0)845 621 1111 • Fax: +44(0)845 621 1112 E-mail: [email protected] • Website: www.stroma.com Certificate No. 967PI to LPS 1531: Issue 1 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barrier and linear gap seals. Appendix 2 - Fire rated board and cladding to structural elements. Appendix 3 - Intumescent coatings to structure elements.
Thermal Engineering Contracts Ltd 38 Whitehouse Street, , Leeds LS10 1AD, United Kingdom Tel: +44(0) 1132 430254 • Fax: +44(0) 5603 430284 E-mail: [email protected] • Website: www.tecl.uk.com Certificate No. 963PI to LPS 1531: Issue 1.0 Company assessed and approved for installation of passive fire protection products under the following scope. Appendix 1 - Penetration, cavity barriers and linear gap seals.
12
20 Nov 2011
PART 1: SECTION 2 CONSTRUCTION PRODUCT SYSTEMS (BUILDING ENVELOPE, ROOFING & PARTITIONS)
This section includes the reaction to fire and fire resistance approval schemes for construction systems including building envelope, roofing and partitions. This section includes: Section 2.1 Section 2.1.1 Section 2.1.2 Section 2.1.3 Section 2.1.4 Section 2.2 Section 2.3 Section 2.3.1 Section 2.3.2 Section 2.4 Section 2.4.1 Section 2.4.2 Section 2.5 Section 2.5.1 Section 2.5.2 Section 2.6
20 Nov 2011
LPS 1181 Series LPS 1181 Lining materials LPS 1181-1 Cladding products used for the external envelope of buildings. LPS 1181-2 Sandwich panels or built-up panel systems used internally in a building. LPS 1181-3 (Draft) Cladding used in POD construction LPS 1208 Composite construction elements LPS 1581 External cladding systems on a masonry substrate LPS 1581 External thermal insulated cladding (ETICS) LPS 1581 Rain screen cladding systems (RSC) LPS 1582 External cladding systems supported by a structural steelwork frame LPS 1582 External thermal insulated cladding (ETICS) LPS 1582 Rain screen cladding system (RSC) Roofing products Protection against fire outside of the building Protection against fire from inside the building Reaction to Fire (RTF) classifications for Materials and Products
13
PART 1: SECTION 2.1 LPS 1181 SERIES
The LPS 1181 series of fire growth standards cover the requirements for LPCB approval and listing of construction product systems. These standards evaluate the fire performance of sandwich panels, built-up cladding systems and other construction product systems to ensure they will not significantly contribute to fire growth in their defined end use applications as detailed in the following listings. The use and application of the LPS 1181 standards are as follows:
The LPS 1181 series of standards cover sandwich panels and built up cladding systems including jointing and fixing methods, sealants, gaskets and flashings.
The LPS 1181 series of standards are used by the insurance industry for property protection purposes.
The requirements of the Building Regulations are not addressed by the LPS 1181 series of standards.
The Building Regulations define the life safety requirements for buildings.
Approved Document B (produced by Communities and Local Government) provides guidance on meeting the requirements of the Building Regulations for fire safety and utilises the test data from the applicable BS 476 series and/or the BS EN 13501 series of standards.
The LPS 1181 series currently consists of the following parts: LPS 1181: Part 1 Requirements and tests for built-up cladding and sandwich panel systems for use as the external envelope of buildings - See Section 2.1.2 LPS 1181: Part 2 Requirements and tests for sandwich panels and built-up systems for use as internal constructions in buildings - See Section 2.1.3 LPS 1181: Part 3 (Draft) Requirements and tests for factory produced room modules (PODS) and building system modules - See Section 2.1.4 Within the LPS 1181 series of standards there are a number of classifications and these are summarised as follows:
14
Cladding systems used for the external envelope of buildings are tested to LPS 1181 part 1. Those products that pass the test are graded into 2 classes: o
Grade EXT-A** - A product that satisfies both the requirements of LPS 1181: Part 1 and also demonstrates fire resistance through a fire resistance test as specified in LPS 1208 (see section 2.2). Such products meet the requirements for separating elements used for compartmentation. (** represents in minutes, the LPCB grading of insulation achieved during the fire resistance tests).
o
EXT B - A product that satisfies the requirements of LPS 1181 part 1 only.
Sandwich panels and built-up systems used internally in a building for the construction of cold stores, factory clean rooms, space separation etc are tested in the large-scale test in LPS 1181 part 2. Those products that pass the test are graded into 3 classes: o
INT 1 - A product that achieves a minimum fire resistance performance of integrity = 60 minutes and insulation = 60 minutes and passes the requirements of the LPS 1181 part 2 large-scale test with an enhanced thermal exposure.
o
INT 2 - A product that achieves a minimum fire resistance performance of integrity = 30 minutes and insulation = 30 minutes and passes the requirements of LPS 1181 part 2 largescale test with a crib ignition source.
o
INT 3 - A product that passes the requirements of LPS 1181 part 2 large-scale test with a crib ignition source but has no fire resistance.
20 Nov 2011
PART 1: SECTION 2.1 LPS 1181 SERIES A guide to example applications with the potential inception risks and associated LPS 1181 classes (part 1 and 2) can be found in appendices 1, 3 and 4 of “Technical briefing: Fire performance of sandwich panel systems” published by the Association of British Insurers in May 2003. It is the responsibility of end users, whether they be specifiers, regulators, insurers, architects etc, to satisfy themselves that any performance claims made by the manufacturers are valid by reference to a relevant certificate, listing and/or test reports and that the product satisfies all the necessary regulatory and design requirements. This responsibility also extends to ensuring that the systems are installed correctly and in accordance with the manufacturer’s instructions.
20 Nov 2011
15
PART 1: SECTION 2.1.1 LPS 1181 LINING MATERIALS
The products listed in this section are intended to provide an additional, separate internal lining material to improve the thermal insulation of light steel or concrete industrial, agricultural and storage buildings. The listed products are often installed during the refurbishment of such buildings. These products have been tested to ensure that they do not significantly contribute to a developing fire. The fire properties of these lining materials have been determined from the relevant criteria of the series of fire growth tests described in the LPS 1181 series of standards. The lining materials are designed to be installed where the fire risk assessment of the building indicates a low to medium risk. Where the fire risk assessment of the building indicates a high fire risk, then products approved to LPS 1181:Part 1 or Part 2, as listed in Sections 2.1.2 and 2.1.3 should be used.
16
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS
LPS 1181: Part 1 Requirements and tests for built-up cladding and sandwich panel systems for use as the external envelope of buildings. This standard determines the contribution to fire growth of built-up cladding and sandwich panel systems used as the external envelope of buildings. The test is a large scale test comprising setting fire to an open-ended enclosure, supported on a steel frame, from the sandwich panels or built-up cladding system. It evaluates the panels, the jointing methods and the supporting system including fixings, which gives an assessment of the true fire performance of the system which cannot be determined from traditional small scale reaction to fire tests, such as surface spread of flame or fire propagation tests. Products that have passed the test and have achieved LPCB approval are graded under the following designations:Grade EXT-A** - A product that satisfies both the requirements of LPS 1181: Part 1 and also demonstrates fire resistance through a fire resistance test as specified in LPS 1208 (see section 2.2). Such products meet the requirements for separating elements used for compartmentation. (** represents in minutes, the LPCB grading of insulation achieved during the fire resistance tests). Grade EXT-B - A product that satisfies the requirements of LPS 1181: Part 1 only.
A Steadman & Son (a division of SIG Trading Ltd), Warnell, Welton, Carlisle, Cumbria CA5 7HH, United Kingdom Tel: +44 (0)16974 78277 • Fax: +44 (0)16974 78530 E-mail: [email protected] • Website: www.steadmans.co.uk Certificate No: 635a to LPS 1181:Part 1
Composite Wall and Ceiling Panels Product Name
Specification Thickness (mm)
AS35/1000 PIR (ceiling panel) AS35/1000 PIR (wall panel)
40, 60, 80, 100 & 120 40 100 & 120 60, 80, 100 & 120
Specification Wall panel orientation (H/V) (note 1) -
Fire Resistance Integrity/Insulation
Core Material
Cert. No.
-
LPS 1181-1 Grade EXT-B
PIR
635a/04
V
-
EXT-B
PIR
V V
120/30 120/15
EXT-A30 EXT-A15
PIR PIR
635a/05
Notes: 1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. LPCB Ref 635a/04 and 635a/05 panels require external overlap stitching using 6.3mm diameter x 22mm steel screws at 300mm centres for wall panels and 450mm centres for ceiling panels. 3. LPCB Ref 635a/04 and 635a/05, wall and/or ceiling side lap joints require a sealant tape (HP500 GCA butyl tape) to be applied during the installation. 4. LPCB Ref 635a/05 maximum unsupported span shall be limited to 1.5m between supports.
ArcelorMittal Construction Belgium NV Lammerdries 8, Industrieterrein Geel West Z4, B-2440 Geel, Belgium Tel: +32 14563943 • Fax: +32 14563952 E-mail: [email protected] • Website: www.arclad.be Certificate No: 939a to LPS 1181: Part 1
20 Nov 2011
17
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS Composite Panels Product Name AMW 1000 (wall panel)
Specification Thickness (mm) 60, 80 & 100
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
AMRW 1000 (wall & roof panel)
40, 50, 60, 80 & 100
-
-
Grade
Core Material
Cert. No.
EXTB EXTB
PIR
939a/01
PIR
939a/02
Grade
Core Material
Cert. No.
EXTB
Mineral Wool
900a/01
1. LPCB Ref. 939a/01 & 939a/02 Wall panels can be laid either vertically or horizontally. 2. LPCB Ref. 939a/02 External side lap joints to be stitched at 300mm centres using Fastovis 5 6,3 x 35mm screws.
Brucha Ges.m.b.H Rusterstrasse 33, A-3451 Michelhausen, Michelhausen, Austria Tel: +43 (2275) 5878 1800 • Fax: +43 (2275) 5875 1804 E-mail: [email protected] • Website: www.brucha.com Certificate No: 900a to LPS1181: Part 1: Issue 1.1 Product Name
Specification Thickness (mm)
WP-F (wall and roof panels)
60, 80, 100, 120, 150 & 200
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
Notes: 1. LPCB Ref. 900a/01 wall panels to be laid with long joint in vertical orientation only.
CA Group Limited Evenwood Industrial Estate, Copeland Road, Evenwood, Co. Durham DL14 9SF, United Kingdom Tel: +44 (0)1388 834242 • Fax: +44(0)1388 834881 E-mail: [email protected] • Website: www.cagroup.ltd.uk Certificate No: 443a to LPS 1181 Part 1: Issue 1 Product Name
Twin-Therm Fire Wall Twin-Therm Wall Twin-Therm Roof Plano-Therm Wall River-Therm Roof SolarWall Wall Plano-Therm Fire Wall SolarWall Fire Wall
Specification System Thickness (mm) 95 - 200 50 - 220 50 - 220 147 - 281 218 - 263 324 - 543 173 - 218 324 - 543
Fire Resistance (min) Integrity 240 -
Fire Resistance (min) Insulation 30 -
120 240
30 30
Grade
Core Material
Cert. No.
EXT-A30 EXT-B EXT-B EXT-B EXT-B EXT-B EXT-A30 EXT-A30
Mineral wool Glass wool Glass wool Glass wool Glass wool Glass wool Mineral wool Mineral wool
443a/02 443a/03 443a/04 443a/05 443a/06 443a/07 443a/08 443a/09
Notes: 1. LPCB Ref. 443a/02, 443a/03, 443a/05, 443a/07, 443a/08 and 443a/09, Wall Panels can be laid vertically or horizontally. For full details contact C A Group 2. LPCB Ref. 443a/02, 443a/03, 443a/05, 443a/07, 443a/08 and 443a/09, The base of wall systems must be supported. 3. LPCB Ref. 443a/02, Twin-Therm Fire Wall: external sheet may be CA 32 1000R, CA 32 1000W, CA 40 1000RW, CA 45 1000W or CA ARC 50 930. 4. LPCB Ref. 443a/03, Twin-Therm Wall: external sheet may be CA 32 1000R, CA 32 1000W, CA 40 1000RW, CA 45 1000W or CA ARC 5. LPCB Ref. 443a/04, Twin-Therm Roof: external sheet may be CA 32 1000R 6. All systems, Internal sheeting normally CA LT 17 1000S. Twin-Therm roof may be lined with CA 32 1000RL.
18
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS
Corus Panels and Profiles Shotton Works, Flintshire CH5 2NH, United Kingdom Tel: +44 (0)1684 856600 • Fax: +44 (0)1684 856601 E-mail: [email protected] • Website: www.coruspanelsandprofiles.com Certificate No: 460a to LPS 1181: Part 1 Issue 1 Product Name
System Specification Thickness (mm) 70
Wall panel orientation (H/V) (note 1) H
Fire Resistance (minutes) Integrity/Insulation
Grade
Core material
Cert. No.
240/16
PIR*
460a/13
90
H
240/27
70 and 90 160-220
V or H V
240/30
80-220
V
240/15
Built up roof (System R1) Built up roof (System R2) Trinsul wall and roof system
60-220 60-220 90 -
-
240/60
Structural Liner Tray Roof system Structural Liner Tray Wall system
190
-
-
EXTA15 EXTA30 EXT-B EXTA30 EXTA15 EXT-B EXT-B EXT-B EXTA60 EXT-B
170
V
-
EXT-B
170
V
120/15
Structural Flat Metal Roof Deck Stratatherm façade Built up acoustic wall and roof systems Built up acoustic wall system
50-200
-
-
EXTA15 EXT-B
80-150 175
H V
-
175
V
240/15
Hybrid Acoustic roof system
120
-
-
Hybrid Acoustic wall system
100
V
240/15
Trisomet 333 (roof and wall panel) Trisomet 333 (wall panel)
40, 60, 80, 100 and 120 60, 80, 100 and 120
H or V
-
V
240/25
Trimapanel wall panel
Built up wall (System W1)
EXT-B EXTA15 EXTA15 EXT-B EXTA15 EXT-B EXTA15
PIR* PIR* Mineral wool
460a/14
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
460a/15 460a/16 460a/19
PIR* / Mineral wool PIR* / Mineral wool PIR* / Mineral wool Mineral wool
460a/20
460a/21
Mineral wool Mineral wool
460a/22 460a/23
Mineral wool PIR* / Mineral wool PIR* / Mineral wool PIR*
460a/24
460a/26
PIR*
460a/27
Notes: 1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. The PIR core materials marked * are both CFC and HCFC Free and are stated to be Low Global Warming Potential (GWP). 3. LPCB Ref 460a/13, Trimapanel wall panels having a grade EXT-A are to be stitched on the internal face with SFS Intec IR2 - 4.8 x 60 (70mm thick panel), or SFS Intec IR2 - 4.8 x 80 (90mm thick panel) screws or similar at maximum 250mm centres. 4. LPCB Ref 460a/19 Trinsul wall system outer liner 0.55mm steel stitched at minimum 600mm centres, internal liner 0.4mm steel. 5. LPCB Ref 460a/20 Structural Liner Tray system requires the liner tray joints to be stitched at minimum 450mm centres. 6. LPCB Ref 460a/21 Structural Flat Metal roof deck steel profile liner D19 - D35 require no side lap stitching, steel profile liner D46 D159 require side lap stitching min. 450mm c/c and steel profile liner D210 require side lap stitching min 350mm c/c. 7. LPCB Ref 460a/26 Trisomet 333 wall panels can be laid with the long joints in the vertical orientation stitched or unstitched, or in the horizontal orientation with the overlap joint stitched at maximum 600mm centres. 8. LPCB Ref 460a/26 Trisomet 333 roof panels are to be secured to each purlin with 3 fixings, the perimeter of the roof system is to be secured to the frame support through the panel edge at 300mm centres. 9. LPCB Ref 460a/27 Trisomet 333 wall panels are to be stitched at maximum 300mm centres with SL2-T-A14-4.8x20 self tapping steel screws or similar.
20 Nov 2011
19
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS
Eurobond Laminates Limited & Eurobond Doors Limited Wentloog Corporate Park, Wentloog, Cardiff CF3 2ER, United Kingdom Tel: + 44 (0)2920 776677 • Fax: + 44 (0)2920 369161 E-mail: [email protected] • Website: www.eurobond.co.uk Product Name
Thickness (mm)
Europanel Extra (wall panel)
Europanel Lite (wall panel)
Europanel Premier (wall panel)
Rockspan Extra (wall panel)
Rockspan Lite (wall panel)
20
Fire Resistance Integrity/Insulation (minutes) 60/60
LPS1181-1 Grade
Core Material
Cert. No.
75
Wall Panel Orientation (V/H)* V or H
EXT-A60
545b/01
100
V or H
60/60
EXT-A60
125
V or H
90/90
EXT-A90
150
V or H
120/120
EXT-A120
175
V or H
120/120
EXT-A120
200
V or H
120/120
EXT-A120
75, 100, 125, 150, 175 & 200 75
V or H
-
EXT-B
V or H
60/30
EXT-A30
100
V or H
60/30
EXT-A30
125
V or H
90/60
EXT-A60
150
V or H
120/90
EXT-A90
175
V or H
120/90
EXT-A90
200
V or H
120/90
EXT-A90
75, 100, 125, 150, 175 & 200 75
V or H
-
EXT-B
V or H
60/60
EXT-A60
100
V or H
60/60
EXT-A60
125
V or H
90/90
EXT-A90
150
V or H
120/120
EXT-A120
175
V or H
120/120
EXT-A120
200
V or H
120/120
EXT-A120
75, 100, 125, 150, 175 & 200 75
V or H
-
EXT-B
V or H
60/60
EXT-A60
100
V or H
120/120
EXT-A120
100
V or H
120/90
EXT-A90
125
V or H
120/120
EXT-A120
150
V or H
120/120
EXT-A120
175
V or H
120/120
EXT-A120
200
V or H
120/120
EXT-A120
75, 100, 125, 150, 175 & 200 75
V or H
-
EXT-B
V or H
60/30
EXT-A30
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
545b/03
545b/04
545b/05
545b/06
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS Product Name
Rockspan Ultima (wall panel)
Rainspan - Argeton terracotta tile system
Rainspan - Linear system
Rainspan - Parklex timber veneer system
Rainspan Rockpanel system
Rainspan - Corium brick slip system
Rainspan - Generic timber system
Rainspan - Clicktile system
Thickness (mm)
Fire Resistance Integrity/Insulation (minutes) 90/60
LPS1181-1 Grade
Core Material
100
Wall Panel Orientation (V/H)* V or H
EXT-A60
125
V or H
90/60
EXT-A60
150
V or H
120/90
EXt-A90
175
V or H
120/90
EXT-A90
200
V or H
120/90
EXT-A90
75, 100, 125, 150, 175 & 150
V or H
-
EXT-B
V or H
240/240
EXT-A240
175
V or H
240/240
EXT-A240
200
V or H
240/240
EXT-A240
120
V or H
120/120
EXT-A120
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
150
V or H
120/120
EXT-A120
175
V or H
180/180
EXT-A180
120
V or H
120/120
EXT-A120
150
V or H
120/120
EXT-A120
175
V or H
180/180
EXT-A180
120
V or H
120/120
EXT-A120
150
V or H
120/120
EXT-A120
175
V or H
180/180
EXT-A180
120
V or H
120/120
EXT-A120
150
V or H
120/120
EXT-A120
175
V or H
180/180
EXT-A180
120
V or H
120/120
EXT-A120
150
V or H
120/120
EXT-A120
175
V or H
180/180
EXT-A180
120
V or H
120/120
EXT-A120
150
V or H
120/120
EXT-A120
175
V or H
180/180
EXT-A180
120
V or H
120/120
EXT-A120
150
V or H
120/120
EXT-A120
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
Cert. No.
545b/07
545b/08
545b/09
545b/10
545b/11
545b/12
545b/13
545b/14
Notes: 1. LPCB Ref No. 545b/07 - 150mm and 175mm Rockspan Ultima wall panel joints are to be stitched on both internal and external faces using 4.7mm diameter x 20mm long self-tapping screws at 300mm centres, the 200mm panel does not require stitching. 2. LPCB Ref No. 545b/13 to 545b/19, the thickness specified relates to the insulated panel thickness only and does not include the facade system depth. * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the insulated panel.
20 Nov 2011
21
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS
Euroclad Limited Wentloog Corporate Park, Wentloog Road, Cardiff CF3 2ER, United Kingdom Tel: +44 (0)2920 790722 • Fax: +44 (0)2920 793149 E-mail: [email protected] • Website: www.euroclad.com Certificate No: 879a to LPS1181: Part 1 Product Name
Elite 1 (Roof System) Elite 2 (Roof System) Elite 3 (Roof System) Elite 4 (Roof System) Elite 51 (wall system)
Elite 52 (wall system)
Elite 53 (wall system)
Elite 54 (wall system)
Elite 55 (wall system)
Elite 56 (wall system)
Elite 57 (wall system)
Elite 58 (wall system)
Elite 60 (wall system)
22
System Specification Thickness (mm) 203 - 252
Wall panel orientation (H/V)
Fire Resisitance (minutes) Integrity/Insulation
Grade
Core material
Cert. No.
-
-/-
EXT-B
879a/05
218 - 312
-
-/-
EXT-B
240 - 335
-
-/-
EXT-B
344 - 395
-
-/-
EXT-B
153 - 173
V
-/-
EXT-B
153 - 173
V
240 / 15
EXT-A15
153 - 173
V
240 / 30
153 - 173
V
-/-
EXT-A30 (note 4) EXT-B
Glass Wool or Mineral Wool Glass Wool or Mineral Wool Glass Wool or Mineral Wool Glass Wool or Mineral Wool Glass Wool or Mineral Wool Glass Wool or Mineral Wool Mineral Wool
153 - 173
V
240 / 15
EXT-A15
153 - 173
V
240 / 15
160
V
-/-
EXT-A30 (note 4) EXT-B
160
V
240 / 15
EXT-A15
160
V
240 / 30
150 - 170
V
-/-
EXT-A30 (note 4) EXT-B
150 - 170
V
240 / 15
EXT-A15
150 - 170
V
240 / 30
180
H
-/-
EXT-A30 (note 4) EXT-B
180
H
240 / 15
EXT-A15
180
H
240 / 30
181
H
-/-
EXT-A30 (note 4) EXT-B
181
H
240 / 15
EXT-A15
181
H
240 / 30
168
H
-/-
EXT-A30 (note 4) EXT-B
168
H
240 / 30
168
H
240 / 15
EXT-A30 (note 4) EXT-A15
177
H
-/-
EXT-B
177
H
240 / 15
EXT-A15
177
H
240 / 30
200
H
-/-
EXT-A30 (note 4) EXT-B
879a/06 879a/07 879a/08 879a/09
Glass Wool or Mineral Wool Glass Wool or Mineral Wool Mineral Wool
879a/10
Glass Wool or Mineral Wool Glass Wool or Mineral Wool Mineral Wool
879a/11
Glass Wool or Mineral Wool Glass Wool or Mineral Wool Mineral Wool
879a/12
Glass Wool or Mineral Wool Glass Wool or Mineral Wool Mineral Wool
879a/13
Glass Wool or Mineral
879a/14
Glass Wool or Mineral Wool Mineral Wool Glass Wool or Mineral Wool Mineral Wool Glass Wool or Mineral Wool Glass Wool or Mineral Wool Glass Wool or Mineral Wool Mineral Wool Glass Wool or Mineral Wool
879a/15
879a/16
879a/17
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS Product Name
System Specification Thickness (mm) 200
Wall panel orientation (H/V)
Fire Resisitance (minutes) Integrity/Insulation
Grade
Core material
H
240 / 15
EXT-A15
200
H
240 / 30
EXT-A30 (note 4)
Glass Wool or Mineral Wool Mineral Wool
Cert. No.
Notes: 1. Where Elite wall systems are required to achieve grade EXT-A15, the internal liner sheet side lap joints must be stitched using steel rivets at 450mm centres. For grade EXT-A30 the internal liner sheet side lap joints must be stitched at 300mm centres. 2. Stitching can be removed from the EXT-A15 wall systems providing that the maximum spacing between sheeting rails is reduced to 1.5m and the internal liner is either Euroclad 1000/32 or MW5 profiles. 3. For wall systems the sheeting rail spacing shall be a maximum of 2m for EXT-B, EXT-A15 & EXT-A30, the external liner must be fixed to the channels of the spacer system using self-drilling, self-tapping screws at nominal 400mm centres for all grades. 4. For grade EXT-A30 systems The minimum permissible stone mineral wool thickness is 180mm, or for systems with horizontally laid external weather sheets where the eurobar spacer rails are vertical and the insulation in the core is supported by additional steel Zsection supports, and with a minimum density of the insulation of 33kg/m³ the minimum insulation thickness can be reduced to 150mm. 5. For Elite roof systems 1 - 4 the maximum purlin spacing is 1.8m. 6. Please refer to BRE Assessment Report CC248407 for approved alternative spacer systems, internal & external profiles, internal & external profile coatings and insulation cores for the Elite systems 1, 2, 3, 4, 51, 52, 53, 54, 55, 56, 57, 58 & 60.
Hemsec Manufacturing Limited Stoney Lane, Rainhill, Prescot, Merseyside L35 9LL, United Kingdom Tel: +44 (0)151 426 7171 • Fax: +44 (0)151 493 1331 E-mail: [email protected] • Website: www.hemsec.com Certificate No: 558b to LPS 1181: Part 1: Issue 1 Product Name
Specification (mm)
Longclad LC1150 Wall (wall panels) Longdeck LD1150 Wall (roof panels) Longclad LC1150 Wall (wall panels)
50mm to 175mm 50mm to 175mm
Longdeck LD1150 Wall (roof panels) SIP Firecheck wall system
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
Grade
Core Material
Cert. No.
EXT-B EXT-B
PIR PIR
558b/01 558b/02
60
30
EXT-A30
PIR
558b/03
100mm to 175mm 125mm to 175mm 160 to 287
52
40
EXT-A30
PIR
558b/04
75
75
PUR
558b/05
257.5 to 329.5
101
101
EXTA60 EXT-A90
PUR
558b/06
Notes: 1. Longclad LC1150 Wall panels LPCB Ref. No. 558b/01 & 558b/03 can be installed with the long joints in the vertical or horizontal orientation. 2. The joints of the Longclad LC1150 wall panel’s 558b/01 should be stitched at 150mm centres on the internal face. 3. The joints of the Longdeck LD1150 roof panel’s 558b/02 should be stitched at 150mm centres on the internal face. 4. The joints of the Longclad LC1150 wall panel’s 558b/03 should be stitched at 150mm centres on the internal and external face. When installed the supporting framework shall provide support at a maximum of 4m centres both horizontally & vertically. 5. The joints of the Longdeck LD1150 roof panel’s 558b/04 should be stitched at 150mm centres on the internal and external face. 6. LPCB Ref 558b/05 - SIP Firecheck wall system was tested and is approved to LPS 1181-1 as a non load-bearing, non structural builtup wall system of the following configuration; Rigid polyurethane foam core (95mm to 222mm thick) sandwiched between 15 mm orientated strand boards (Krono OSB-3), the panel size was 1.2m x 3.0m and installed with 3 metre joints vertical. The system was clad on the fire exposed face with two layers of British Gypsum wall boards; A single layer of ‘Gyproc’ 12.5mm wall board (outer layer) and a single layer of ‘Gyproc Fireline’ 12.5mm board (inner layer), wall board layer joints were staggered by 600mm and fixed to softwood timber battens positioned at 600mm centres with 3.5mm x 50mm dry wall screws at 300mm centres. The system was tested with Hemsec 175mm thick Longdeck LD1150 PIR core roof panels. 7. LPCB Ref 558b/06 - SIP Firecheck wall system is approved to LPS 1181-1 as a non load-bearing, non structural built up wall system of the following configuration; Rigid polyurethane foam core (150mm to 222mm thick) sandwiched between 15 mm orientated strand boards (Krono OSB-3), the panel size is 1.2m x 3.0m and installed with 3 metre joints vertical and consisting of 148mm deep x 70mm thick x 3000mm long timber spline joints inserted into 35mm pre-formed rebates in the core insulation, the joints are fixed with adhesive and nail fixings at 100mm centres. The system is clad on the fire exposed face with two layers of British Gypsum wall boards; A single layer of ‘Gyproc’ 12.5mm wall board (outer layer) and a single layer of ‘Gyproc Fireline’ 15mm board (inner layer),
20 Nov 2011
23
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS with the wall board joints between layers staggered by 600mm and fixed to softwood timber battens 50mm x 50mm spaced at 600mm centres with 3.5mm x 50mm dry wall screws at 300mm centres, the stud cavity is filled with Knauf Rocksilk Universal slab RW33 insulation.
ISOCAB France S.A. Avenue de la Gironde, Z.I. Petite Synthe, 59640 Dunkerque, France Tel: +33 328 29 26 30 • Fax: +33 328 60 11 93 E-mail: [email protected] • Website: www.isocab.be Certificate No: 465a to LPS 1181: Part 1 Product Name
Specification System Thickness (mm)
ISOCAB Industrial (wall and roof panel)
40 - 200
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
Grade
Core Material
Cert. No.
EXT-B
PIR
465a/01
Notes: 1. Wall panels are laid vertically. 2. Both wall and roof panels require internal stitching at 300mm centres using 3.2mm diameter x 25mm screws and internal steel flashings 0.6mm thick x 120mm wide overlaying three beads of Lorient intumescent mastic, stitched at 150mm centres using 3.2mm diameter x 16mm screws.
Kingspan Insulation Limited Pembridge, Leominster, Herefordshire HR6 9LA, United Kingdom Tel: +44 (0)1544 388601 • Fax: +44 (0)1544 388888 E-mail: [email protected] • Website: www.insulation.kingspan.com Certificate No: 388b to LPS 1181: Part 1 Product Name
Roofing systems incorporating Thermaroof TR26 LPC/FM zero ODP Insulation (also available as Thermataper TT46 for cut-to-fall roofing systems) Roofing systems incorporating Thermaroof TR27 LPC/FM zero ODP Insulation (also available as Thermataper TT47 for cut-to-fall roofing systems)
Specification Thickness (system) (mm) 65 to 155
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
Grade
Core Material
Cert. No.
EXTB
HCFCfree PIR
388b/01
65 to 155
-
-
EXTB
HCFRfree PIR
388b/02
Notes: 1. LPCB Ref 388b/01 Thermaroof TR26/ LPC/FM Mechanically Fixed Insulated metal deck system is approved to LPS 1181-1 as a built up roof system of the following configuration: Corus D35 Roof Decking (0.7mm thick) or equivalent; deck panel lap joints stitched at 400mm centres. With or without Corus Kalzip/Icopal Monofilament 250μm or equivalent approved Vapour Control Layer (VCL); loose laid on top of the deck. Kingspan TR26/TT46 LPC/FM foil faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m sheets (approved at 30mm to 120mm thick) the boards through fixed to deck using 140mm long SFS drill point roof fasteners at 3.8 fixings per m² with a 70mm diameter metal plate washer. Weather sealed using Protan SE membrane (1.2mm x 1000mm) having a 120mm lap joint with a 40mm hot air weld, or equivalent woven polyester reinforced PVC water proof membrane, mechanically fixed to the roof system using RP75 x 100mm telescopic tube washers and 4.8 x 60mm screw fixed to the metal deck at 150mm centres. The membrane must be restrained around the edges of the deck with an edge restraint bar stitched at 400mm centres. The roof system was tested in combination with LPCB approved PIR core wall panels. 2. LPCB Ref 388b/02 Thermaroof TR27 LPC/FM Mechanically Fixed Insulated metal deck system is approved to LPS 1181-1 as a built up roof system of the following configuration: Corus D35 Roof Decking (0.7mm thick) or equivalent; deck panel lap joints stitched at 400mm centres. With or without Corus Kalzip/Icopal Monofilament 250μm or equivalent approved Vapour Control Layer (VCL); loose laid on top of the deck.
24
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS
Kingspan TR27/TT47 LPC/FM glass tissue faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m sheets (approved at 30mm to 120mm thick) the boards through fixed to deck using 140mm long SFS drill point roof fasteners at 3.8 fixings per m² with a 70mm diameter metal plate washer. Weather sealed using Protan SE membrane (1.2mm x 1000mm) having a 120mm lap joint with a 40mm hot air weld, or equivalent woven polyester reinforced PVC water proof membrane, mechanically fixed to the roof system using RP75 x 100mm telescopic tube washers and 4.8 x 60mm screw fixed to the metal deck at 150mm centres. The membrane must be restrained around the edges of the deck with an edge restraint bar stitched at 400mm centres. The roof system was tested in combination with LPCB approved PIR core wall panels.
3. LPCB Ref. 388b/01 and 388b/02 certification is also valid for insulation boards manufactured at Kingspan Insulation Ltd, Castleblayney, County Monaghan, Ireland (LPCB FPC reference number 858).
Kingspan Ltd Carrickmacross Road, Kingscourt, Co. Cavan, Ireland Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77 E-mail: [email protected] • Website: www.kingspanpanels.com Certificate No: 186a to LPS 1181: Part 1: Issue 1.1 Specification Kingspan Model Specification Ref. (note 2) 31 Rev 1
Fire Resistance Integrity/Insulation (minutes)
LPS 11811 Grade
Core Material (note 3)
Cert. No.
95 - 150
Specification Wall panel orientation (H/V) (note 1) V or H
-
EXT-B
260a/70
30 - 120
V or H
17 Rev 6
-
EXT-B
40 - 120
V
17 Rev 6
144 / 18
100 & 120
V
17 Rev 6
241 / 43
30 - 120
-
27 Rev 2
-
EXTA15 EXTA30 EXT-B
30 - 120
V or H
19 Rev 4
-
EXT-B
40 - 120
V
19 Rev 4
144 / 18
100 - 120
V
19 Rev 4
241 / 43
30 - 120
V
5 Rev 5
-
EXTA15 EXTA30 EXT-B
60 - 120
V
4 Rev 4
-
EXT-B
80 - 120
-
4 Rev 4
-
EXT-B
30 - 120
-
12 Rev 3
-
EXT-B
30 - 120
-
28 Rev 1
-
EXT-B
45 - 100
-
10 Rev 3
-
EXT-B
Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecoafe PIR Ecosafe PIR PIR
45 - 124
-
8 Rev 8
-
EXT-B
45 - 115
-
2 Rev 4
-
EXT-B
45 - 115
-
3 Rev 4
-
EXT-B
40 - 100
V
29 Rev 0
-
EXT-B
80 - 100
V
29 Rev 0
69 / 23
40 - 100
-
29 Rev 0
-
EXTA15 EXT-B
34, 46, 68, 80, 100 & 120 66
-
30 Rev 1
-
EXT-B
-
15 Rev 4
-
EXT-B
Product Name
Specification Thickness (mm)
Kingspan Benchmark Trespa System Kingspan KS1000 RW (roof and wall panel) Kingspan KS1000 RW (wall panel) Kingspan KS1000 RW/FW30 (wall panel) Kingspan KS2000 RW (roof panel) Kingspan KS1000 SF (roof and wall panel) Kingspan KS1000 SF (wall panel) Kingspan KS1000 SF/FW30 (wall panel) Kingspan KS1000 BU (roof and wall panel) Kingspan KS1000 LJ (wall panel) Kingspan KS1000 LJ (roof panel) Kingspan KS1000 TS (roof panel) Kingspan KS2000 TS (roof panel) Kingspan KS1000 RT Rooftile (roof panel) Kingspan KS500 Zip & KS1000 Zip (roof panel) Kingspan KS1000 LP (roof panel) Kingspan KS1000 CR (roof panel) Kingspan KS1000 DR (wall panel) Kingspan KS1000 DR (roof panel) Kingspan KS1000 TD (roof panel) BenchmarkTopspan (roof panel) (roof panel)
20 Nov 2011
Ecosafe PIR Ecosafe PIR Ecosafe PIR PIR
186a/42 186a/38 186a/40 260a/69 186a/43 186a/39 186a/41 186a/46 186a/44 186a/45 186a/47 260a/68 279a/10 260a/54 279a/65 279a/66 279a/16
PIR
279a/17
Ecosafe PIR Ecosafe PIR PIR
279a/34 279a/29 279a/31
25
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS Product Name
Specification Thickness (mm)
Kingspan KS600 - 1200 MR, FL, FL-S, EB, WV, MM, CX , PL, Benchmark Evolution & KS1000 TL, Benchmark Louvre DW & Benchmark Curve DW (wall panel) Kingspan KS600 - 1000 MR, FL, FL-S, EB, WV, MM, CX, PL, Benchmark Evolution & KS1000 TL (wall panel) Kingspan KS600 - 1000 LS (wall panel) Kingspan KS600 - 1000, Benchmark Render DW (wall panel) Kingspan KS600 - 1000 FX (wall panel) Kingspan KS1000 EP Energi (wall and roof panel) Kingspan KS1000 FC (wall and roof panel ) Kingspan KS1000 FC (wall and roof panel) Kingspan KS1000 FC (wall panel) Kingspan KS1000 FC (wall panel) Kingspan Benchmark Metallic ACM Tray Kingspan Benchmark Wood Composite System Kingspan Benchmark Ceramic Granite System Thermabrick Façade system Kingspan Benchmark Ceramic Tile System Kingspan KS1100 CS (wall panel) Kingspan KS1100 CS (ceiling panel)
Specification Kingspan Model Specification Ref. (note 2) 18 Rev 8
Fire Resistance Integrity/Insulation (minutes)
LPS 11811 Grade
Core Material (note 3)
Cert. No.
45 - 140
Specification Wall panel orientation (H/V) (note 1) V or H
-
EXT-B
Ecosafe PIR
260a/37
70 - 140
V
18 Rev 8
40 / 15
EXTA15
Ecosafe PIR
260a/36
100 - 140
V
18 rev 8
132 / 28
H
9 Rev 5
-
45 - 100
V or H
20 Rev 2
-
EXT-B
Ecosafe PIR Ecosafe PIR Ecosafe PIR
260a/64
80 - 140
EXTA30 EXT-B
70 - 100
V
20 Rev 2
40 / 15
45 - 100
V or H
21 Rev 4
-
EXTA15 EXT-B
68 - 100
V
25 Rev 0
-
EXT-B
34 - 100
V or H
16 Rev 3
-
EXT-B
34 - 100
V or H
16 Rev 3
-
68 - 100
V
16 Rev 3
34 / 15
100
V
16 Rev 3
79 / 34
95 - 150
V or H
26 Rev 5
-
EXT B EXTA15 EXTA30 EXT-B
94 - 149
V or H
24 Rev 3
-
EXT-B
95 - 150
V or H
23 Rev 4
-
EXT-B
120 - 150
V
23 Rev 4
73 / 35
110 - 165
V
22 Rev 4
-
EXTA30 EXT-B
135 - 165
V
22 Rev 4
220 / 83
80 - 135
V or H
14 Rev 5
-
105 - 135
V
14 Rev 5
32 / 32
80 - 200
V
13 Rev 2
-
80 - 200
-
13 Rev 2
-
EXTA60 EXT-B EXTA30 EXT B EXT-B
Ecosafe PIR Ecosafe PIR Ecosafe PIR
260a/67 260a/49 260a/50 260a/53 279a/30
Ecosafe PIR PIR
279a/32 279a/19
PIR
279a/21
PIR
279a/28
Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR
260a/62 260a/59 260a/58 260a/63 260a/60 260a/61 260a/35 260a/34 279c/15 279c/16
Notes: 1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. The Kingspan Model Specification documents contain full system details including panel fixing requirements, joint seals and stitching details as applicable, reference must be made to the appropriate Model Specification to define the specific approved installation requirements. Copies of Model Specification’s are available on request, Please contact the Kingspan Envirocare Department. 3. Core material solutions listed as Ecosafe PIR are CFC/HCFC/HFC Free, Low GWP. Core material solutions listed as PIR are CFC/HCFC Free.
26
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS
Kingspan Ltd. Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161 E-mail: [email protected] • Website: www.kingspanpanels.com Certificate No: 260a to LPS 1181: Part 1: Issue 1.1 Product Name
Specification Thickness (mm)
Kingspan Benchmark Trespa System Kingspan KS1000 RW (roof and wall panel) Kingspan KS1000 RW (wall panel) Kingspan KS1000 RW/FW30 (wall panel) Kingspan KS2000 RW (roof panel) Kingspan KS1000 SF (roof and wall panel) Kingspan KS1000 SF (wall panel) Kingspan KS1000 SF/FW30 (wall panel) Kingspan KS1000 BU (roof and wall panel) Kingspan KS1000 LJ (wall panel) Kingspan KS1000 LJ (roof panel) Kingspan KS1000 TS (roof panel) Kingspan KS2000 TS (roof panel) Kingspan KS1000 RT Rooftile (roof panel) Kingspan KS500 Zip & KS1000 Zip (roof panel) Kingspan KS1000 LP (roof panel) Kingspan KS1000 CR (roof panel) Kingspan KS1000 DR (wall panel) Kingspan KS1000 DR (roof panel) Kingspan KS1000 TD (roof panel) Kingspan Benchmark Topspan (roof panel) Kingspan KS600 -1200 MR, FL, FL-S, EB, WV, MM, CX , PL, Benchmark Evolution, KS1000 TL, Benchmark Louvre DW & Benchmark Curve DW (wall panel) Kingspan KS600 - 1000 MR, FL, FL-S, EB, WV, MM, CX, PL, Benchmark Evolution & KS1000 TL (wall panel)
20 Nov 2011
Specification Kingspan Model Specification Ref. (note 2) 31 Rev 1
Fire Resistance Integrity/Insulation (minutes)
LPS 1181 1 Grade
Core Material (note 3)
Cert. No.
95 - 150
Specification Wall Panel Orientation (H/V) (note 1) V or H
-
EXT-B
260a/70
30 - 120
V or H
17 Rev 6
-
EXT-B
40 - 120
V
17 Rev 6
144 / 18
100 & 120
V
17 Rev 6
241 / 43
30 - 120
-
27 Rev 2
-
EXTA15 EXTA30 EXT-B
30 - 120
V or H
19 Rev 4
-
EXT-B
40 - 120
V
19 Rev 4
144 / 18
120
V
19 Rev 4
241 / 43
30 - 120
V
5 Rev 5
-
EXTA15 EXTA30 EXT-B
60 - 120
V
4 Rev 4
-
EXT-B
80 - 120
-
4 Rev 4
-
EXT-B
30 - 120
-
12 Rev 3
-
EXT-B
30 - 120
-
28 Rev 1
-
EXT-B
45 -100
-
10 Rev 3
-
EXT-B
Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR PIR
45 -124
-
8 Rev 8
-
EXT-B
45 - 115
-
2 Rev 4
-
EXT-B
45 - 115
-
3 Rev 4
-
EXT-B
40 - 100
V
29 Rev 0
-
EXT-B
80 - 100
V
29 Rev 0
69 / 23
40 - 100
-
29 Rev 0
-
EXTA15 EXT-B
34, 46, 68, 80, 100 & 120 66
-
30 Rev 1
-
EXT-B
-
15 Rev 4
-
EXT-B
45 - 140
V or H
18 Rev 8
-
70 - 140
V
18 Rev 8
40 / 15
Ecosafe PIR Ecosafe PIR Ecosafe PIR PIR
260a/42 260a/38 260a/40 260a/69 260a/43 260a/39 260a/41 260a/46 260a/44 260a/45 260a/47 260a/68 279a/10 260a/54 279a/65 279a/66 279a/19
PIR
279a/17
Ecosafe PIR Ecosafe PIR PIR
279a/34
EXT-B
Ecosafe PIR
260a/37
EXTA15
Ecosafe PIR
260a/36
279a/29 279a/31
27
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS Product Name
Kingspan KS600 - 1000 LS (wall panel) Kingspan KS600 - 1000, Benchmark Render DW (wall panel) Kingspan KS600 - 1000 FX (wall panel) Kingspan KS1000 EP Energi (wall and roof panel) Kingspan KS1000 FC (wall and roof panel ) Kingspan KS1000 FC (wall and roof panel) Kingspan KS1000 FC (wall panel) Kingspan KS1000 FC (wall panel) Kingspan Benchmark Metallic ACM Tray Kingspan Benchmark Wood Composite System Kingspan Benchmark Ceramic Granite System Thermabrick Façade system Kingspan Benchmark Ceramic Tile System Kingspan KS1100 CS (wall panel) Kingspan KS1100 CS (ceiling panel)
Specification Thickness (mm)
Specification Kingspan Model Specification Ref. (note 2) 18 Rev 8
Fire Resistance Integrity/Insulation (minutes)
LPS 1181 1 Grade
Core Material (note 3)
Cert. No.
100 - 140
Specification Wall Panel Orientation (H/V) (note 1) V
132 / 28
H
9 Rev 5
-
45 - 100
V or H
20 Rev 2
-
EXT-B
Ecosafe PIR Ecosafe PIR Ecosafe PIR
260a/64
80 - 140
EXTA30 EXT-B
70 - 100
V
20 Rev 2
40 / 15
45 - 100
V or H
21 Rev 4
-
EXTA15 EXT-B
Ecosafe PIR Ecosafe
68 - 100
V
25 Rev 0
-
EXT-B
Ecosafe PIR
279a/30
34 - 100
V or H
16 Rev 3
-
EXT-B
279a/32
34 - 100
V or H
16 Rev 3
-
EXT-B
Ecosafe PIR PIR
279a/19
68 - 100
V
16 Rev 3
34 / 15
PIR
279a/21
100
V
16 Rev 3
79 / 34
PIR
279a/28
95 - 150
V or H
26 Rev 5
-
EXTA15 EXTA30 EXT-B
260a/62
94 - 149
V or H
24 Rev 3
-
EXT-B
Ecosafe PIR Ecosafe PIR
95 - 150
V or H
23 Rev 4
-
EXT-B
120 - 150
V
23 Rev 4
73 / 35
110 - 165
V
22 Rev 4
-
EXTA30 EXT-B
135 - 165
V
22 Rev 4
220 / 83
80 - 135
V or H
14 Rev 5
-
105 - 135
V
14 Rev 5
32 / 32
80 - 200
V
13 Rev 2
-
EXTA30 EXT-B
80 - 200
-
13 Rev 2
-
EXT-B
EXTA60 EXT-B
Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR Ecosafe PIR
260a/67 260a/49 260a/50 260a/53
260a/59 260a/58 260a/63 260a/60 260a/61 260a/35 260a/34 279c/15 279c/16
Notes: 1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. The Kingspan Model Specification documents contain full system details including panel fixing requirements, joint seals and stitching details as applicable, reference must be made to the appropriate Model Specification to define the specific approved installation requirements. Copies of Model Specifications are available on request. Please contact the Kingspan Envirocare Department. 3. Core material solutions listed as Ecosafe PIR are CFC/HCFC/HFC Free, Low GWP. Core material solutions listed as PIR are CFC/HCFC Free.
Modular Panel Systems Limited Mohill, Co.Leitrim, Ireland Tel: +353 719631162 • Fax: +353 719651979 E-mail: [email protected] • Website: www.modular.ie Certificate No: 750b to LPS 1181: Part 1 Product Name
Specification Thickness (mm)
PIR ExoClad (wall and ceiling panel)
50
28
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
Grade
Core Material
Cert. No.
EXT-B
PIR
750b/01
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS Product Name
Specification Thickness (mm)
PIR ExoClad (wall panel)
50
Fire Resistance (min) Integrity 120
Fire Resistance (min) Insulation 16
Grade
Core Material
Cert. No.
EXT-A15
PIR
750b/02
Notes: 1. The joints of the Exoclad panels 750b/01 should be stitched with 6.3mm x 22mm long self tapping screws @ 250mm centres on the external overlap and stitched with 4.8mm dia x 10mm stainless steel rivets @ 250mm centres on the internal face. 2. Wall panels to be orientated vertically only. 3. Exoclad wall panels 750b/02, panel joints external overlap stitched with stainless steel rivets and screwed at 100 mm centres. The internal joint is stitched at 100mm centres and protected with a 250mm wide by 50mm deep insulated cover strip stitched at 100mm centres.
N.V. Joris IDE Hille 174, B-8750, Zwevezele, Belgium Tel: +44 (0)1928 571 444 • Fax: +44 (0)1928 571 488 E-mail: [email protected] • Website: www.joriside.co.uk Hille 174, B-8750, Zwevezele, Belgium Tel: +44 (0)1928 571 444 • Fax: +44 (0)1928 571 488 E-mail: [email protected] • Website: www.joriside.co.uk
Certificate No: 700a to LPS1181: Part 1: Issue 1 Product Name
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
Grade
Core Material
Cert. No.
Isotherm Built up system (wall panels)
Specification System Thickness (mm) 200
EXT-B
700a/06
Isotherm Built up system (roof panels)
220
-
-
EXT-B
JI ROOF 1+2 1000 (roof and wall panels) JI ROOF 1+2 1000 (wall panel)
30 - 120 60 - 120
67
17
JI ROOF 1+2 1000 with Tile System (roof panels) JI WALL SF 1060/1000/900/600 (wall panels) JI WALL SF 1060/1000/900/600 (wall panels -vertical orientation only) JI WALL SF 1060/1000/900/600 (wall panels) JI PERMAPAN 1100 (roof panels)
100 - 120
-
-
EXT-B EXTA15 EXT-B
Glass mineral wool Glass mineral wool PIR PIR PIR
700a/11
60 - 120
-
-
EXT-B
PIR
700a/12
60 - 120
61
20
PIR
700a/13
60 - 120
30
15
PIR
700a/14
40-100
-
-
EXTA15 EXTA15 EXT-B
PIR
700a/15
700a/07 700a/09 700a/10
Notes: 1. LPCB Ref. No. 700a/06 internal linings to be horizontal and external linings to be vertical 2. LPCB Ref. No. 700a/09 roof and wall panels fixed through every valley with 5.5mm self drilling/tapping screws into the roof and wall rail locations. Roof panel overlaps between adjoining panels shall be stitched at 300mm centres with 4.8mm self drilling/tapping screws or equivalent. 3. LPCB Ref. No. 700a/09 wall panels can be laid with the long joints in the vertical or horizontal orientation. 4. LPCB Ref. No. 700a/10 wall panels to be laid with the long joints in the horizontal orientation only. The panels were fixed through every valley with 5.5mm self drilling/tapping screws into the wall rail locations. The panel overlaps between panel joints were stitched at 250mm centres with 4.8mm self drilling/tapping screws. Maximum unsupported span between rails 1760mm. 5. LPCB Ref. No. 700a/11 roof panels fixed through every valley with 5.5mm self drilling/tapping screws into the roof rail locations. The panel overlaps between panel joints were stitched at 300mm centres with 4.8mm self drilling/tapping screws. The tile system comprised of timber battens 50mm x 25mm fixed to the crown of every profile overlayed with single roman clay tiles with a maximum load of 42kg/m2. 6. LPCB Ref. No. 700a/12 wall panels can be laid with the long joints in the vertical or horizontal orientation. 7. LPCB Ref. No. 700a/13 wall panels to be laid with the long joints in the vertical orientation only, the panel joints shall be stitched on the fire side with 5.5mm x 50mm self tapping screws at maximum centres of 100mm. 8. LPCB Ref. No. 700a/14 wall panels can be laid with the long joints in the vertical or horizontal orientation, the panel joints shall be stitched on the fire side with 5.5mm x 50mm self tapping screws at maximum centres of 100mm. 9. LPCB Ref. No 700a/15. Roof panel overlaps between adjoining panels shall be stitched at 300mm centres with 4.8mm self drilling/tapping screws or equivalent.
20 Nov 2011
29
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS
Quinn Therm Limited Scotchtown, Ballyconnell, Co. Cavan, Ireland Tel: +353 49 952 5604 • Fax: +353 49 952 5601 E-mail: [email protected] • Website: www.quinn-therm.com Certificate No: 893a to LPS1181: Part 1 Product Name QRFR Fully adhered Insulating metal deck roof system QRFR Mechanically Fixed metal deck roof system
Specification Thickness (mm) 85 - 185
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
85 - 185
-
-
Grade
Core Material
Cert. No.
EXTB EXTB
PIR
893a/01
PIR
893a/02
Notes: 1. LPCB Ref 893a/01 QRFR Fully adhered Insulating metal deck roof system is approved to LPS 1181-1 as a built-up roof system of the following configuration: • • • • • • 2.
Steadmans AS34 single skin roof profile deck (0.7mm thick); deck panel lap joints stitched at 250mm centres. Multilfold 250µm Vapour Control Layer (VCL) laid on top of the deck, with the VCL cut back to within 75mm from the edge of the deck perimeter and further protected by flashing installed to form an ‘upstand’ around the perimeter of the roof system. 150mm thick Quinntherm QRFR glass fibre tissue faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m sheets (tested at 150mm thick, but available and approved between 50mm to 150mm thick), the boards being through fixed to the steelwork using 6.3 x 175mm fastec CR10 fluro carbon coated screws, with discs, at six fixings per m2 Weather sealed using a Sika-Trocal SGK 1.5 (1.5mm x 1100mm) water proof membrane adhered to the Quinntherm Insulation using Sika-Trocal C300 adhesive at a rate of 250 g/m². The 150mm insulation roof system tested incorporated a 150 x 200mm external edge flashing and a 300 x 300mm internal roof/wall 1.6mm galvanised steel flashing. The roof system was tested in combination with LPCB approved PIR core wall panels.
LPCB Ref 893a/02 QRFR Mechanically fixed Insulating metal deck roof system is approved to LPS 1181-1 as a built-up roof system of the following configuration: • • • • • •
Steadmans AS34 single skin roof profile deck (0.7mm thick); deck panel lap joints stitched at 300mm centres. Multilfold 250µm Vapour Control Layer (VCL) laid on top of the deck, with the VCL cut back to within 75mm from the edge of the deck perimeter and further protected by flashing installed to form an ‘upstand’ around the perimeter of the roof system. 150mm thick Quinntherm QRFR foil faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m sheets (tested at 150mm thick, but available and approved between 50mm to 150mm thick), the boards being through fixed to the steelwork using 6.3 x 175mm fastec CR10 fluro carbon coated screws in a 500mm x 500mm square pattern. Weather sealed using a Sika-Trocal Type S 1.5 (1.5mm x 1100mm) water proof membrane mechanically fixed to the roof system using Trocal Metal Discs and Fasteners secured in place by the 6.3 x 175mm fastec CR10 fluro carbon coated screws mentioned above. The 150mm insulation roof system tested incorporated a 150 x 200mm external edge flashing and a 300 x 300mm internal roof/wall 1.6mm galvanised steel flashing. The roof system was tested in combination with LPCB approved PIR core wall panels.
Recticel Insulation Products / Recticel N.V Enterprise way, Meir Park, Stoke-On-Trent ST3 7UN, United Kingdom Tel: +44 (0)1782 590470 • Fax: +44(0)1782 590499 E-mail: [email protected] • Website: www.recticelinsulation.com Recticel N.V Tramstraat 6, B-8560, Wevelgem, Belgium
Certificate No: 968a to LPS 1181: Part 1: Issue 1
30
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS Product Name
Roofing system incorporating Eurothane Silver Roofing system incorporating Powerdeck F
Specification Thickness (System) (mm) 65 - 155
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
65 - 155
-
-
Grade
Core Material
Cert. No.
EXTB EXTB
PIR
968a/01
PIR
968a/02
Notes: 1. LPCB Ref 968a/01 Eurothane Silver Mechanically Fixed Insulated metal deck system is approved to LPS 1181-1 as a built up roof system of the following configuration: · Corus D35 Roof Decking (0.7mm thick) or equivalent; deck panel lap joints stitched at 400mm centres. · Eurothane Silver foil faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 2.4m x 1.2m sheets (approved at 30mm to 120mm thick) the boards through fixed to deck using BS 4.8 x 130mm screws & SFS Isotak RP75 x 30 tube washers with a 183mm PVC disk sitting on top of the PIR insulation at 600mm centres · Weather sealed using Fatra Fatrafol 810AA (1.5mm x 1300mm) Single ply membrane having its lap joint’s hot air welded in accordance with manufacturer's recommendations, or equivalent single ply water proof membrane, the membrane is bonded to the 183mm PVC disks using Fatra FF855 adhesive, brush applied. · The roof system was tested in combination with LPCB approved PIR core wall panels. 2. LPCB Ref 968a/02 Powerdeck F Mechanically Fixed Insulated metal deck system is approved to LPS 1181-1 as a built up roof system of the following configuration: · Corus D35 Roof Decking (0.7mm thick) or equivalent; deck panel lap joints stitched at 400mm centres. · Powerdeck F glass tissue faced Insulation layer of rigid polyisocyanurate (PIR) boards supplied in 1.2m x 0.6m sheets (approved at 30mm to 120mm thick) the boards through fixed to deck using BS 4.8 x 130mm screws & SFS Isotak RP75 x 30 tube washers with a 183mm PVC disk sitting on top of the PIR insulation at 600mm centres · Weather sealed using Fatra Fatrafol 810AA (1.5mm x 1300mm) Single ply membrane having its lap joint’s hot air welded in accordance with manufacturer's recommendations, or equivalent single ply water proof membrane, the membrane is bonded to the 183mm PVC disks using Fatra FF855 adhesive, brush applied. · The roof system was tested in combination with LPCB approved PIR core wall panels.
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022g to LPS1181: Part 1: Issue 1.1 Product Name
Hardrock DD roof board system
Hardrock DD SPA roof board system
DuoRock roof board system
Specification System Thickness (mm) (1) 210
Fire Resistance (min) Integrity 120
Fire Resistance (min) Insulation 120
100 - 135 100 - 210 140 - 205 210
60 90 120
60 90 120
100 - 135 100 - 210 140 - 205 100 - 210 100 - 210
60 90 60 -
60 90 60 -
Grade (2)
Core Material
Cert. No.
EXTA120 EXT-A60 EXT-B EXT-A90 EXTA120 EXT-A60 EXT-B EXT-A90 EXT-A60 EXT-B
Stone wool
022g/01
Stone wool Stone wool Stone wool Stone wool
022g/02
Stone wool Stone wool Stone wool Stone wool Stone wool
022g/03
Notes: 1. Roof board system LPCB Ref No. 022g/01 & LPCB Ref No. 022g/03: Mechanically fastened Sarnafil single ply type S327-12EL (1.2mm thickness), external weather proof membrane (or alternative membrane less than 3.5 kg/m² e.g. PVC, Chlorinated PE, Butyl Rubber with welded seams); Comprising of two layers of Rockwool roofing board with staggered joints (100mm minimum stagger for fire resistance up to 90 minutes and 300mm stagger for 2 hours fire resistance), vapour control layer and 0.7mm thickness 35mm deep profile steel metal deck. Roof board system LPCB Ref No. 022g/02: Sarnafil single ply external weather proof membrane type G410-12EL (1.2mm thickness), fully adhered to Hardrock DD SPA roof board system with Sarnifil Adhesive(or Rockwool approved alternative adhesive/membrane combination, with a membrane material less than 3.5 kg/m² e.g. PVC, Chlorinated PE, Butyl Rubber with welded seams); comprising
20 Nov 2011
31
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS of two layers of Rockwool roofing board with staggered joints (100mm minimum stagger for fire resistance up to 90 minutes and 300mm stagger for 2 hours fire resistance), vapour control layer and 0.7mm thickness 35mm deep profile steel metal deck. Roof Board System LPCB Ref No 022g/01, 022g/02 & 022g/03 Hardrock DD, Hardrock DD SPA and DuoRock roofing boards are also available and approved in cut-to-fall tapered options, the relevant minimum & maximum system thickness and staggered joints shall apply as detailed above. 2. For EXT-A fire resistance grading, the test construction was tested unloaded. However, deflection of the roof did not exceed the allowable limits set out in BS 476: Part 20: 1987 for loadbearing horizontal elements. 3. Decking side laps were stitched at 450mm centres. The built up roofing system was tested with Eurobond Stone wool core sandwich wall panels.
Ruukki Polska Sp. z.o.o ul Jaktorowska 13, 96-300, Zyradow, Poland Tel: 0121 704 7300 • Fax: 0121 711 9712 E-mail: [email protected] • Website: www.ruukki.com Certificate No: 1052a to LPS 1181-1 Product Name
Specification Thickness (mm)
SP2B UK (wall panel)
100
SP2C UK (ceiling panel)
SP2D UK (wall panel) SP2E UK (wall panel)
Wall panel orientation (H/V) (Note 1) H
Fire Resistance Integrity/Insulation (mins) 61/34
LPS1181 1 Grade
Core Material
Cert. No.
EXT-A30
PIR
1052a/01
100 40, 60, 80 and 100 80 and 100 120/80, 140/100 and 210/170
V H/V H -
61/30 53/17 63/37
EXT-A30 EXT-B EXT-A15 EXT-A30
PIR PIR PIR PIR
1052a/02
80/40, 100/60, 120/80, 140/100 and 210/170 80/40, 100/60, 120/80, 140/100 and 210/170 100
-
-
EXT-B
PIR
-
91/19
EXT-A15
PIR
V
50/22
EXT-A15
PIR
1052a/03
60, 80 and 100 120, 160, 180 and 200
H/V H/V
-
EXT-B EXT-B
PIR PIR
1052a/04
120, 160, 180 and 200
V
46/25
EXT-A15
PIR
Notes: 1. Wall panel orientatin, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. LPCB Ref 1052a/02 EXT-B grade ceiling panels, joints shall be stitched on the external face using 4.9 x 19mm zinc coated carbon steel self drilling fasteners at nominal 300mm centres. 3. LPCB Ref 1052a/02 EXT-A15 grade 80/40, 100/60, 120/80, 140/100 and 210/170 ceiling panels were fire resistance tested with an imposed load of 24kg/m2. The maximum unsupported span shall be limited to 2.0m between supports and the panel joints shall be stitched on the external face using 4.9 x 19mm zinc coated carbon steel self drilling fasteners at nominal 300mm centres. 4. LPCB Ref 1052a/02 EXT-A30 grade 120/80, 140/100 and 210/170 ceiling panels were fire resistance tested with an imposed load of 32kg/m2. The maximum unsupported span shall be limited to 2.0m between supports and the panel joints shall be stitched on the external face using 4.9 x 19mm zinc coated carbon steel self drilling fasteners at nominal 300mm centres.
SpeedDeck Building Systems Limited Oaksmere Business Park, Yaxley, Eye, Suffolk IP23 8BW, United Kingdom Tel: +44 (0)1379 788166 • Fax: +44 (0)1379 788161 E-mail: [email protected] • Website: www.eleco.co/speeddeck Certificate No: 738a to LPS 1181: Part 1 Product Name
SpeedDeck double skin roof system
32
Specification System Thickness (mm) 180 - 220
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
Grade
Core Material
Cert. No.
EXTB
Glass wool
738a/01
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS Product Name
SpeedZip double skin roof system
Specification System Thickness (mm) 180 - 220
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
PP32 double skin roof system
180 - 220
-
-
SpeedRoof double skin roof system
180 - 220
-
-
Grade
Core Material
Cert. No.
EXTB EXTB EXTB
Glass wool
738a/02
Glass wool
738a/03
Glass wool
738a/04
Notes: 1. LPCB Ref. 738a/01 SpeedDeck double skin roof system: external sheet may be 0.9mm 3004 grade embossed plain aluminium or 0.9mm aluminium coated with a 25 micron PVdF or 30 micron ARS paint finish or 0.6mm or 0.7mm steel with a 200 micron PVC paint finish i.e. Corus HPS200 or Dobel 200XT outer skin and Walkliner inner skin. 2. LPCB Ref. 738a/02 SpeedZip double skin roof system: 0.9mm aluminium with a stucco plain or 25 micron PVdF or 30 micron ARS paint finish outer skin and Walkliner inner skin. 3. LPCB Ref. 738a/03 PP32 double skin roof system: 0.7mm steel trapezoidal 32mm profile with a Dobel 200XT 200 micron PVC paint finish outer skin and Walkliner inner skin, outer skin lap joints stitched at 450mm centres. 4. LPCB Ref. 738a/04 SpeedRoof double skin roof system: 0.7mm steel profile with Corus HPS200, Dobel 200XT or Dobel Nova outer skin finish and Walkliner inner skin.
ThyssenKrupp Steel Europe AG Hammerstrasse 11, D-57223 Kreuztal, Germany Tel: +49 (0)2723 599 1221 • Fax: +49 (0)2723 599 1219 E-mail: [email protected] • Website: www.thyssenkrupp-bausysteme.com www.thyssenkrupp-steel-europe.com Certificate No: 657a to LPS 1181: Part 1 Product Name
Specification Thickness (mm)
Hoesch isowand integral (wall panel) Hoesch isowand vario (wall panel) Hoesch isowelle (wall panel) Hoesch isorock integrad D (roof panel) Hoesch isowand vario (wall panel) Hoesch Thermodach (roof panel) Hoesch isodach integral (roof panel) Hoesch isodach mono (roof panel)
Fire Resistance Integrity / Insualation
LPS 11811 Grade
Core Material
Cert. No.
60 - 120
Specification Wall Panel Orienation (H/V) (See Note 1) H/V
-/-
EXT-B
PIR
657a/01
60 - 140 64 - 104 95 - 155
H/V H/V -
-/-/-/-
EXT-B EXT-B EXT-B
657a/02 657a/03 657a/04
100 - 140 80 - 140 80 - 140 75 - 130 75 - 155
H H V -
42 / 49 32 / 24 61 / 26 -/-/-
EXT-A30 EXT-A15 EXT-A15 EXT-B EXT-B
PIR PIR Mineral fibre PIR PIR PIR PIR PIR
95 - 155
-
-/-
EXT-B
PIR
657a/08
657a/05 657a/06 657a/07
Notes: 1. Wall orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. LPCB Ref. No 657a/04 - Roof panel joints are held by use of an aluminium locking system and covered with a continuous joint cover, cover ledge part No. S33-052. 3. LPCB Ref. No. 657a/05 - Wall panels are stitched on the internal face using 5.5 x 70mm stainless steel screws at 150mm centres. 4. LPCB Ref. No. 547a/05 Grade EXT-A15 Wall panel joints are stitched on the external face with 4.2mm self tapping stainless steel screws and nominal 400mm centres. 5. LPCB Ref. No. 657a/06, 657a/07 and 657a/05 - Roof panel joints are stitched on the external face with 4.8mm self tapping stainless steel scres and nominal 900mm centres. 6. LPBC Ref. No. 657a/07 and 657a/08 - Roof panel jonts are held by use of a locking system and covered with a continuous joint cover.
20 Nov 2011
33
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS
Trimo d.d Prijatljeva 12, 8210 Trebnje, Slovenija Tel: 00386 73460200 • Fax: 0038 673460127 E-mail: [email protected] • Website: www.trimo.eu UK Supplier Trimo UK Ltd, Unit 4 Willaston House, Crewe Road, Nantwich, Cheshire CW5 6NE, United Kingdom Tel: +44 (0) 1270 665303 • Fax: +44 (0) 1270 664294 E-mail: [email protected] • Website: www.trimo.org.uk
Certificate No: 650b to LPS 1181: Part 1 Product Name
Trimotherm FTV (wall panel) Trimotherm SNV (ceiling panel)
Specification System Thickness (mm) 100 - 150 100
Fire Resistance (min) Integrity 95 98
Fire Resistance (min) Insulation 95 95
Grade
Core Material
Cert. No.
EXT-A90 EXT-A90
Mineral wool Mineral wool
650b/01 650b/02
Note: LPCB Ref. No. 650b/01 wall panels can be laid either horizontally or vertically.
Xtratherm Limited Kells Road, Navan, Co. Meath, Ireland Tel: +353 46 906 6000 • Fax: +353 46 906 6090 E-mail: [email protected] • Website: www.xtratherm.com Certificate No: 851a to LPS 1181: Part 1: Issue 1.1 Product Name
XT/FR-Alu Roof system XT/TR-Alu roof System XT/FR-MG Roof System XT/TR-MG Roof System
Specification System Thickness (mm) 66 - 136
Fire Resistance (minutes) Integrity
Fire Resistance (minutes) Insulation
Grade
Insulation Material
Cert. No.
-
-
PIR
851a/01
66 - 136
-
-
66 - 136
-
-
66 - 136
-
-
EXTB EXTB EXTB EXTB
PIR PIR
851a/02
PIR
Notes: 1. LPCB Ref 851a/01, the built-up roof system tested and approved consists of; • PVC Membrane laid in lengths across the width of the roof, mechanically fixed with hot-air welded lap joints. • 100mm XT/SP XT/FR-Alu or XT/TR-Alu PIR insulation boards (available and approved between 30mm to 100mm thick) mechanically fixed using a minimum of 6 fasteners per 2.4m x 1.2m board; each fastener incorporated a 50mm x 50mm square plate spreader washer. Boards laid in a break bond pattern. • 1mm gauge Vapour Control Layer - loose lay. • 0.7mm gauge, 35mm deep profiled metal deck with overlap side laps stitched at 400mm centres. 2. LPCB Ref 851a/02, the built-up roof system tested and approved consists of; • PVC Membrane laid in lengths across the width of the roof, solvent welded to the PIR insulation boards with HA-C membrane adhesive at a rate of 250g/m2 and with solvent welded lap joints. • 100mm XT/SP XT/FR-MG or XT/TR-MG PIR insulation boards (available and approved between 30mm to 100mm thick) mechanically fixed using a minimum of 6 fasteners per 2.4m x 1.2m board; each fastener incorporated a 50mm x 50mm square plate spreader washer. • 1mm gauge Vapour Control Layer- loose lay. • 0.7mm gauge, 35mm deep profiled metal deck with overlap side laps stitched at 400mm centres.
34
20 Nov 2011
PART 1: SECTION 2.1.2 LPS 1181-1 CLADDING PRODUCTS USED FOR THE EXTERNAL ENVELOPE OF BUILDINGS 3. LPCB Ref 851a/01 & 851a/02, the built-up roof systems were tested and approved in combination with a 150mm mineral wool cored sandwich panel wall elements.
20 Nov 2011
35
PART 1: SECTION 2.1.3 LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING
LPS 1181:Part 2 Requirements and tests for sandwich panels and built-up systems for use as internal constructions in buildings This standard determines the contribution to fire growth of sandwich panels and built-up cladding systems used internally within a building. Systems listed in this section are typically used for the construction of food factory clean rooms, cold store rooms/refrigerated spaces or room separation, other internal structure applications may also be applicable where insulated (acoustic or temperature controlled) spaces are specified. The structures are either self-supporting or supported by an external structure. The test is a large scale test comprising setting fire to an open-ended enclosure (approximately the size of a large domestic garage) from the sandwich panels or built-up cladding system. It evaluates the panels, the jointing methods and the supporting system including fixings, which gives an assessment of the true fire performance of the system which cannot be determined from traditional small scale reaction to fire tests, such as surface spread of flame or fire propagation tests. Products that have passed the test and have achieved LPCB approval are graded under the following designations:
GRADE
INT-1 INT-2 INT-3
Requirements for internal applications Fire resistance Wall and ceiling lining test Thermal exposure Integrity (minutes) Insulation (minutes) Level Source 60 60 Enhanced Gas burner 30 30 Standard Timber crib Standard Timber crib
Brucha Ges.m.b.H Rusterstrasse 33, A-3451 Michelhausen, Michelhausen, Austria Tel: +43 (2275) 5878 1800 • Fax: +43 (2275) 5875 1804 E-mail: [email protected] • Website: www.brucha.com Certificate No: 900b to LPS1181-2 Product Name
Specification Thickness (mm)
WP-F (wall panel)
60, 80, 100, 120, 150 & 200 60, 80, 100, 120, 150 & 200
WP-F (ceiling panel)
Maximum Unsupported Panel Span (m) 3.0
Fire Resistance (min) Integrity
3.5
Grade
Core Material
Cert. No.
-
Fire Resistance (min) Insulation -
INT-3
Mineral Wool
900b/01
-
-
INT-3
Mineral Wool
900b/02
Notes: 1. LPCB ref 900b/01 WP-F Wall panels to be installed with no external supports & the long edge joint in the vertical orientation only. 2. LPCB ref 900b/01 & 900b/02 Wall and ceiling panel joints to be stitched on the internal face with 3.2 mm blind rivets at nominally 300mm centres. 3. LPCB ref 900b/02 WP-F Ceiling panels are supported by a hanger system consisting of. · A length of wire rope (4.0mm 6 x 7N 1AX) passed over and supported from a suitable load bearing frame. · An M10 turnbuckle with the rope secured using a ‘U bolt and clamp. · A length of M10 studding is passing through a hole which is drilled in the panel and secured on the internal surface with an 80mm diameter washer and domed head nut, this is further protected with a 0.55mm thick steel box (130mm-square x 30mm-deep with 130mm x 30mm-flanges), lined with Promatect board and fixed using 3.2mm blind rivets. · The turn buckle is then adjusted to accommodate the weight of the panels.
36
20 Nov 2011
PART 1: SECTION 2.1.3 LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING
Eurobond Laminates Limited & Eurobond Doors Limited Wentloog Corporate Park, Wentloog, Cardiff CF3 2ER, United Kingdom Tel: + 44 (0)2920 776677 • Fax: + 44 (0)2920 369161 E-mail: [email protected] • Website: www.eurobond.co.uk Certificate No: 545c to LPS1181: Part 2: Issue 2 Product Name
Specification Thickness (mm)
Firemaster Wall Lite
75 75 100 100 100 100 125 125 125 150 150 150 150 175 175 175 200 200 200 75 75 100 100 100 125 125 125 125 150 150 150 175 175 175 75 100 100 125 125 150 150 150 175 200
Firemaster Wall Extra
Firemaster Ceiling Panel
Firemaster Wall Ultima
Maximum Unsupported Panel Length (m) 3.00 3.00 4.00 4.50 4.50 5.50 4.00 4.50 5.50 5.00 5.50 5.50 5.50 5.00 5.00 5.50 5.00 5.00 5.50 3.00 3.00 5.50 5.50 6.00 5.50 5.50 6.00 7.50 7.5 7.5 7.50 7.50 7.50 7.50 6.00 4.20 6.00 4.20 6.00 4.20 6.0 7.50 7.50 7.50
Fire Resistance (min) Integrity 30 60 90 60 60 30 90 60 30 120 60 60 90 90 120 60 90 120 60 30 60 90 120 60 90 120 60 30 60 120 90 60 90 120 60 60 60 240 240 240
Fire Resistance (min) Insulation 30 30 60 60 60 30 60 60 30 90 60 60 90 90 90 60 90 90 60 30 60 90 120 60 90 120 60 30 60 120 90 60 90 120 60 60 60 240 240 240
Grade
Core Material
Cert. No.
INT-2 INT-2 INT-1 INT-1 INT-1 INT-2 INT-1 INT-1 INT-2 INT-1 INT-1 INT-1 INT-1 INT-1 INT-1 INT-1 INT-1 INT-1 INT-1 INT-2 INT-1 INT-1 INT-2 INT-1 INT-1 INT-1 INT-1 INT-2 INT-1 INT-1 INT-1 INT-1 INT-1 INT-1 INT-3 INT-1 INT-3 INT-1 INT-3 INT-1 INT-3 INT-1 INT-1 INT-1
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
545c/01
545c/02
545c/03
545c/05
Notes: 1. Grade INT-1 approved products have equal performance at Grade INT-2 and INT-3 2. Grade INT-2 approved products have equal performance at Grade INT-3 3. LPCB Ref No. 545c/02 - Where Eurobond 120 rock fibre insulation core is used in the 100mm thick panel the fire resistance insulation performance is limited to 90 minutes for maximum unsupported panel lengths of 5.5m 4. LPCB Ref No. 545c/05 - 150mm and 175mm Firemaster Wall Ultima panel joints are to be stitched on both internal and external faces using 4.7mm diameter x 20mm long self-tapping screws at 300mm centres, the 200mm panel does not require stitching
20 Nov 2011
37
PART 1: SECTION 2.1.3 LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING
Excel Industries Ltd Maerdy Industrial Estate (South), Rhymney, Gwent NP22 5PY, United Kingdom Tel: +44 (0)1685 845200 • Fax: +44 (0)1685 844106 E-mail: [email protected] • Website: www.excelfibre.com Certificate No: 721a to LPS 1181: Part 2: Issue 2 Product Name
Specification Thickness (mm)
Maximum Unsupported Panel Length
Warmcel built-up wall panel system
System thickness 293 (note 1)
Warmcel built-up ceiling panel system
System thickness 329.2 (note 2)
Self supporting system on fixed footplate (note 3) Supported on wall panel system (note 4)
Fire Resistance (min) Integrity -
Fire Resistance (min) Insulation -
Grade
Core Material
Cert. No.
INT-3
Warmcel 500 cellulose fibre
721a/01
-
-
INT-3
Warmcel 500 cellulose fibre
721a/02
Notes: 1. LPCB Ref. No. 721a/01 wall panel build specification Inner layer - 2 off layers (staggered joints) 10mm Sasmox Fire resistant & acoustic panel Core - 245mm void created by timber I beams at a maximum of 600mm centres, void filled with Warmcel 500 full fill insulation dry fill at 45-55kg/m3 density Outer layer - 2 off layers (staggered joints) 10mm Sasmox Fire resistant & acoustic panel Alternative panel types for outer and inner layers - two layers of 10mm Xella Fermacell or 12.5mm Gyproc Fireline wallboard or 12.5mm Lafarge Firecheck wallboard 2. LPCB Ref. No. 721a/02 ceiling panel build specification Inner layer - 2 off layers (staggered joints) 10mm Sasmox Fire resistant & acoustic panel Core - 300mm void created by timber I beams at a maximum of 600mm centres, void filled with Warmcel 500 full fill insulation dry fill at 45-55kg/m3 density Outer layer - single layer 9.2mm panel vent board Alternative panel types for inner layers - two layers of 10mm Xella Fermacell or 12.5mm Gyproc Fireline wallboard or 12.5mm Lafarge Firecheck wallboard 3. No external supports for wall panel system used during test, maximum spans used during test, 10 metre long x 3 metre high. 4. Ceiling panel system supported around perimeter on wall panel system only, no additional external supports used. Maximum spans used during test, 10 metre long x 4.5 metre wide.
Paneltex Limited Kingston International Business Park, Somerden Road, Kingston-upon-Hull HU9 5PE, United Kingdom Tel: 01482 787236 • Fax: 01482 787238 E-mail: [email protected] • Website: www.paneltex.co.uk Certificate No: 993a to LPS 1181 Part 2: Issue 2.0 Product Name Paneltex Fireproof Coldstore (wall and ceiling panel system)
Specification Thickness (mm) 165
Maximum system size See Note 2
Fire resistance (minutes) Integrity/Insulation -/-
Grade INT-3
Core Material PIR
Cert. No. 993a/01
Notes: 1. LPCB Ref 993a/01 Paneltex Fireproof Coldstore wall and ceiling panel systems to be installed with no external supports, the wall panels have the long edge joint in the horizontal orientation. 2. LPCB Ref 993a/01 The maximum internal length and width of the Paneltex Fireproof Coldstore system shall not exceed 14.277m x 3.584m.
38
20 Nov 2011
PART 1: SECTION 2.1.3 LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING
Trimo d.d Prijatljeva 12, 8210 Trebnje, Slovenija Tel: 00386 73460200 • Fax: 0038 673460127 E-mail: [email protected] • Website: www.trimo.eu UK Supplier Trimo UK Ltd, Unit 4 Willaston House, Crewe Road, Nantwich, Cheshire CW5 6NE, United Kingdom Tel: +44 (0) 1270 665303 • Fax: +44 (0) 1270 664294 E-mail: [email protected] • Website: www.trimo.org.uk
Certificate No: 650c to LPS 1181: Part 2: Issue 2 Product Name
Specification Thickness (mm)
Trimotherm FTV (wall panel)
20 Nov 2011
Fire Resistance (min) Integrity 30
Fire Resistance (min) Insulation 30
Maximum Unsupported Span (m)
Grade
Core Material
Cert. No.
100
Specification Orientation of Long Edges Horizontal
7.25
INT-2
Mineral wool
650c/01
100
Horizontal
60
60
7.25
INT-2
100
Horizontal
90
90
5.60
INT-2
100
Vertical
30
30
7.25
INT-2
100
Vertical
60
60
7.25
INT-2
100
Vertical
90
90
5.60
INT-2
120
Horizontal
30
30
8.00*
INT-2
120
Horizontal
60
60
8.00*
INT-2
120
Horizontal
90
90
8.00*
INT-2
120
Horizontal
120
120
8.00
INT-2
120
Vertical
30
30
7.25
INT-2
120
Vertical
60
60
7.25
INT-2
120
Vertical
90
90
5.60
INT-2
120
Vertical
120
120
4.00
INT-2
150
Horizontal
30
30
8.00*
INT-2
150
Horizontal
60
60
8.00*
INT-2
150
Horizontal
90
90
8.00*
INT-2
150
Horizontal
120
120
8.00
INT-2
150
Horizontal
180
180
4.00
INT-2
150
Vertical
30
30
7.25
INT-2
150
Vertical
60
60
7.25
INT-2
150
Vertical
90
90
6.00
INT-2
150
Vertical
120
120
5.50
INT-2
150
Vertical
180
180
4.00
INT-2
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
39
PART 1: SECTION 2.1.3 LPS 1181-2 SANDWICH PANELS OR BUILT-UP PANEL SYSTEMS USED INTERNALLY IN A BUILDING
Note: 1. LPCB Ref. No. 6"50c/01 - unsupported spans marked *, span can be extended to 10.4m in respect of the length of the panel in horizontal laid orientation only.
40
20 Nov 2011
PART 1: SECTION 2.1.4 LPS 1181-3 (DRAFT) CLADDING USED IN POD CONSTRUCTION
LPS 1181: Part 3 (Draft) Requirements and tests for factory produced room modules (PODS) and building system modules ‘PODS’ are prefabricated units forming a room containing all structural elements and linings and may include services and fittings. This section covers PODS constructed of sandwich panels walls and/or ceilings. For units listed in this section, the wall and ceiling construction has been tested to LPS 1181:Part 3 (Draft). The testing does not assess the structural performance of the POD under test nor the effect of doors or windows within the structure.
Portakabin Ltd New lane, Huntington, , York YO32 9PT, United Kingdom Tel: 01904 611655 • Fax: 01904 611644 E-mail: [email protected] • Website: www.portakabin.co.uk Certificate No: 592a(2) to LPS1181 Part 3 Product Name ULTIMA Building System Building Module (wall) ULTIMA Building System Building Module (ceiling) ULTIMA Building System Building Module (roof)
Specification Sandwich panel thickness only 76mm & 89mm thick 47mm thick
Fire Resistance (min) Integrity 60
Fire Resistance (min) Insulation 15
Grade
Core Material
Cert. No.
A
PUR
592a/03
60
60
A
PUR
592a/04
110mm thick
-
-
B
PUR
592a/05
Notes: 1. LPCB Ref. No. 592a/03, 592a/04 & 592a/05 Test specimen conformed to LPS1181 size requirements, except width was only 3.6m, the maximum width possible for the module. 2. LPCB Ref. No. 592a/03 Wall panels laid with long joints in the vertical orientation. 3. LPCB Ref. No. 592a/04 The test specimen for the ceiling fire resistance test was a combined ceiling and floor construction 4. LPCB Ref. No. 592a/03 Wall inner surface lining 1x layer 12.5mm thick Gyproc Fireline Duplex, Lafarge GTEC Fire V or Knauf Fireshield Plasterboard with Renolit Minster PVC innerface lining. 5. LPCB Ref. No. 592a/04 & 592a/05 Inner surface: interior polyester steel. 6. LPCB Ref. No. 592a/03, 592a/04 & 592a/05 No assessment has been made of the structural performance of the module, or of the inclusion of windows and doors. Therefore there has been no evaluation of the performance should the fire break through a window or door. 7. LPCB Ref. No. 592a/03, 592a/04 & 592a/05 Test Specimen short wall was 89mm thick and the long walls were 76mm thick.
Yorkon Limited New Lane, Huntington, York YO32 9PT, United Kingdom Tel: +44 (0)1904 610990 • Fax: +44 (0)1904 610880 E-mail: [email protected] • Website: www.yorkon.co.uk Certificate No: 592a(1) to LPS 1181: Part 3
Yorkon Room and Building Modules Product Name
Yorkon Room Module (wall) Yorkon Room Module (ceiling) Yorkon Building Module (wall) Yorkon Building Module (ceiling) Yorkon Building Module (roof)
20 Nov 2011
Specification (sandwich panel thickness only) (mm) 70 47 76 and 89 47 110
Fire Resistance (min) Integrity 60 60 60 60 -
Fire Resistance (min) Insulation 15 60 15 60 -
Grade
Core Material
Cert. No.
A A A A B
PUR PUR PUR PUR PUR
592a/01 592a/02 592a/03 592a/04 592a/05
41
PART 1: SECTION 2.1.4 LPS 1181-3 (DRAFT) CLADDING USED IN POD CONSTRUCTION Notes: 1. LPCB Ref. No. 592a/01, 592a/02, 592a/03, 592a/04 & 592a/05 Test specimen conformed to LPS1181 size requirements, except width was only 3.6m, the maximum width possible for the module. 2. LPCB Ref. No. 592a/01 & 592a/03 Wall panels laid with long joints in the vertical orientation. 3. LPCB Ref. No. 592a/01 Wall inner surface lining 1x layer 15mm thick Gyproc Fireline Duplex, Lafarge GTEC Fire V or Knauf Fireshield taper edge plasterboard 4. LPCB Ref. No. 592a/02 Ceiling inner surface lining 2 layers 15mm thick Gyproc Fireline Plasterboard 83mm below lower surface of PUR sandwich panel 5. LPCB Ref. No. 592a/02 & 592a/04 The test specimen for the ceiling fire resistance test was a combined ceiling and floor construction 6. LPCB Ref. No. 592a/03 Wall inner surface lining 1x layer 12.5mm thick Gyproc Fireline Duplex, Lafarge GTEC Fire V or Knauf Fireshield taper edge plasterboard. 7. LPCB Ref. No. 592a/04 & 592a/05 Inner surface: interior polyester steel 8. LPCB Ref. No. 592a/01, 592a/02, 592a/03, 592a/04 & 592a/05 No assessment has been made of the structural performance of the module, or of the inclusion of windows and doors. Therefore there has been no evaluation of the performance should the fire break through a window or door. 9. LPCB Ref. No. 592a/03, 592a/04 & 592a/05 Test Specimen short wall was 89mm thick and the long walls were 76mm thick
42
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS
LPS 1208: LPCB test and performance requirements for walls, cavity barriers, floors and roofs defines the test and performance requirements to satisfy the fire resistance requirements for compartmentation given in the LPC Design Guide for Fire Protection of Buildings: 2000. Products for use in the following elements of construction fall within the scope of LPS 1208:
Loadbearing compartment walls Non-loadbearing compartment walls and partitions External walls Curtain walls Cavity barriers Roofs where fire resistance is required (loadbearing and non-loadbearing) Loadbearing compartment floors Insulated panels used for enclosing production and storage areas in food factories
Note: Unless otherwise stated in individual listings, elements of construction have not been approved for load bearing capacity.
ArcelorMittal Construction Belgium Zone Industrielle de Martinrou, 21b rue de Berlaimont, Fleurus, Belgium Tel: +32 (0) 718 70540 • Fax: +32 (0) 718 70541 Website: www.arcelormittal.com Certificate No: 737a to LPS 1208
Promistyl Feu (Wall panel) Product Name
Specification Thickness (mm)
Promistyl Feu 3003 (Wall panel)
Promistyl Feu 3506 (Wall panel)
Wall Panel Orientation (H/V) (note 1)
Max. Unsupported span (m)
Grade
Core material
Cert. No.
120 - 200
Fire Resistance (min) Integrity / Insulation (BS 476: Part 22) 120/120
H
4.2
FR120
Mineral fibre
737a/01
120 - 200
120/120
V
4.0
FR120
120 - 200
30/30
H/V
7.5
FR30
120 - 200
60/60
H
7.5
FR60
120 - 200
60/60
V
6.2
FR60
120 - 200
90/60
H
5.6
FR90
120 - 200
90/90
V
4.1
FR90
80 - 100
120/60
V
4.0
FR60
80 - 100
30/30
V
6.6
FR30
80 - 100
60/60
V
4.0
FR60
80 - 100
90/60
V
4.0
FR60
120 - 200
30/30
H
7.5
FR30
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
120 - 200
60/60
H
4.0
FR60
737a/02
Mineral fibre
Note: 1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation.
20 Nov 2011
43
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS 2. LPCB ref No. 737a/01 & 737a/02 Promistyl Feu 3003 & 3506 wall panels are available with 0.5 to 0.63mm smooth, ribbed or grooved internal steel facing and 0.5 to 0.75mm smooth, ribbed, micro-ribbed or grooved external external steel facing.
Eurobond Laminates Limited & Eurobond Doors Limited Wentloog Corporate Park, Wentloog, Cardiff CF3 2ER, United Kingdom Tel: + 44 (0)2920 776677 • Fax: + 44 (0)2920 369161 E-mail: [email protected] • Website: www.eurobond.co.uk Certificate No: 545a to LPS 1208: Issue 2
Firemaster Wall Extra Product Name
Thickness (mm)
Wall Panel Orientation (V/H) * V or H
Maximum Unsupported Span (m) 3.0
Grade
Core Material
Cert. No.
75
Fire Resistance Integrity/Insulation (min) 30/30
Firemaster Wall Extra
FR30
545a/01
75
60/60
V or H
3.0
FR60
100
120/120
V or H
5.5
FR120
100
120/90
V or H
5.5
FR90
100
30/30
V or H
7.5
FR30
100
60/60
V or H
6.0
FR60
100
90/90
V or H
5.5
FR90
125
120/120
V or H
5.5
FR120
125
30/30
V or H
7.5
FR30
125
60/60
V or H
6.0
FR60
125
90/90
V or H
5.5
FR90
150
120/120
V or H
7.5
FR120
150
30/30
V or H
7.5
FR30
150
60/60
V or H
FR60
150
90/90
V or H
7.5 7.5 7.5
175
120/120
V or H
7.5
FR120
175
30/30
V or H
7.5
FR30
175
60/60
V or H
7.5
FR60
175
90/90
V or H
7.5
FR90
200
120/120
V or H
7.5
FR120
200
30/30
V or H
7.5
FR30
200
60/60
V or H
7.5
FR60
200
90/90
V or H
7.5
FR90
Mineral Fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
FR90
Note: * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel. Certificate No: 545a to LPS 1208: Issue 2
44
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Firemaster Ceiling Panel Product Name
Thickness (mm)
Wall Panel Orientation (V/H) -
Maximum Unsupported Span (m) 4.2
Grade
Core Material
Cert. No.
100
Fire Resistance Integrity/Insulation (min) 60/60
Firemaster Ceiling Panel
FR60
545a/02
125
60/60
-
4.2
FR60
150
60/60
-
4.2
FR60
150
120/120
-
3.0
FR120
150
120/120
-
3.5
FR120
150
60/60
-
6.0
FR60
150
90/90
-
4.5
FR90
150
90/90
-
4.7
FR90
Mineral fibre Mineral fibre Mineral fibre Mineral Fibre (note 2) Mineral fibre Mineral fibre Mineral fibre (note 2) Mineral fibre
545a/12
Note: 1. LPCB ref 545a/12 - Ceiling panels to be stitched on both internal and external faces using 3.8mm diameter x 16mm long stainless steel rivets or 4.7mm diameter x 20mm long steel stitching screws at 300mm centres. 2. Tervol DP-LX 12 stone mineral wool insulation core.
Certificate No: 545a to LPS 1208: Issue 2
Firemaster Wall Lite Product Name
Thickness (mm)
Firemaster Wall Lite
20 Nov 2011
Wall Panel Orientation (V/H) * V or H
Maximum Unsupported Span (m) 3.0
Grade
Core Material
Cert. No.
75
Fire Resistance Integrity/Insulation (min) 30/30
FR30
545a/03
75
60/30
V or H
3.0
FR30
100
30/30
V or H
5.5
FR30
100
60/60
V or H
4.5
FR60
100
90/60
V or H
4.0
FR60
125
30/30
V or H
5.5
FR30
125
60/60
V or H
4.5
FR60
125
90/60
V or H
4.0
FR60
150
120/90
V or H
5.0
FR90
150
30/30
V or H
5.5
FR30
150
60/60
V or H
5.5
FR60
150
90/90
V or H
5.0
FR90
175
120/90
V or H
5.0
FR90
175
30/30
V or H
5.5
FR30
175
60/60
V or H
5.5
FR60
175
90/90
V or H
5.0
FR90
200
120/90
V or H
5.0
FR90
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
45
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
Thickness (mm)
Wall Panel Orientation (V/H) * V or H
Maximum Unsupported Span (m) 5.5
Grade
Core Material
200
Fire Resistance Integrity/Insulation (min) 30/30
FR30
200
60/60
V or H
5.5
FR60
200
90/90
V or H
5.0
FR90
Mineral fibre Mineral fibre Mineral fibre
Cert. No.
Note: * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel. Certificate No: 545a to LPS 1208: Issue 2
Europanel Extra (wall panel) Product Name
Thickness (mm)
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span(m) 3.0
Grade
Core Material
Cert. No.
75
Fire Resistance Integrity/Insulation (min) 30/30
Europanel Extra (wall panel)
FR30
Mineral fibre
545a/05
75
60/60
V or H
3.0
FR60
100
30/30
V or H
7.5
FR30
100
60/60
V or H
6.0
FR60
125
30/30
V or H
7.5
FR30
125
60/60
V or H
6.0
FR60
125
90/90
V or H
5.5
FR90
150
120/120
V or H
7.5
FR120
150
30/30
V or H
7.5
FR30
150
60/60
V or H
7.5
FR60
150
90/90
V or H
7.5
FR90
175
120/120
V or H
7.5
FR120
175
30/30
V or H
7.5
FR30
175
60/60
V or H
7.5
FR60
175
90/90
V or H
7.5
FR90
200
120/120
V or H
7.5
FR120
200
30/30
V or H
7.5
FR30
200
60/60
V or H
7.5
FR60
200
90/90
V or H
7.5
FR90
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
Note: * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel. Certificate No: 545a to LPS 1208: Issue 2
46
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Europanel Premier (wall panel) Product Name
Thickness (mm)
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported span (m) 3.0
Grade
Core Material
Cert. No.
75
Fire Resistance Integrity/Insulation (min) 30/30
Europanel Premier (wall panel)
FR30
Mineral fibre
545a/06
75
60/60
V or H
3.0
FR60
100
30/30
V or H
7.5
FR30
100
60/60
V or H
6.0
FR60
125
30/30
V or H
7.5
FR30
125
60/60
V or H
6.0
FR60
125
90/90
V or H
5.5
FR90
150
120/120
V or H
7.5
FR120
150
30/30
V or H
7.5
FR30
150
60/60
V or H
7.5
FR60
150
90/90
V or H
7.5
FR90
175
120/120
V or H
7.5
FR120
175
30/30
V or H
7.5
FR30
175
60/60
V or H
7.5
FR60
175
90/90
V or H
7.5
FR90
200
120/120
V or H
7.5
FR120
200
30/30
V or H
7.5
FR30
200
60/60
V or H
7.5
FR60
200
90/90
V or H
7.5
FR90
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
Note: * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel. Certificate No: 545a to LPS 1208: Issue 2
Europanel Lite (wall panel) Product Name
Thickness (mm)
Europanel Lite (wall panel)
20 Nov 2011
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span (m) 3.0
Grade
Core Material
Cert. No.
75
Fire Resistance Integrity/Insulation (min) 30/30
FR30
Mineral fibre
545a/07
75
60/30
V or H
3.0
FR30
100
30/30
V or H
5.5
FR30
100
60/30
V or H
4.5
FR30
125
30/30
V or H
5.5
FR30
125
60/60
V or H
4.5
FR60
125
90/60
V or H
4.0
FR60
150
120/90
V or H
5.0
FR90
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
47
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
Thickness (mm)
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span (m) 5.5
Grade
Core Material
150
Fire Resistance Integrity/Insulation (min) 30/30
FR30
150
60/60
V or H
5.5
FR60
150
90/90
V or H
5.0
FR90
175
120/90
V or H
5.0
FR90
175
30/30
V or H
5.5
FR30
175
60/60
V or H
5.5
FR60
175
90/90
V or H
5.0
FR90
200
120/90
V or H
5.0
FR90
200
30/30
V or H
5.5
FR30
200
60/60
V or H
5.5
FR60
200
90/90
V or H
5.0
FR90
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
Cert. No.
Note: * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel. Certificate No: 545a to LPS 1208: Issue 2
Rockspan Extra (wall panel) Product Name
Thickness (mm)
Rockspan Extra (wall panel)
48
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span (m) 3.0
Grade
Core Material
Cert. No.
75
Fire Resistance Integrity/Insulation (min) 30/30
FR30
Mineral fibre
545a/08
75
60/60
V or H
3.0
FR60
100
120/120
V or H
5.5
FR120
100
120/90
V or H
5.5
FR90
100
30/30
V or H
7.5
FR30
100
60/60
V or H
6.0
FR60
100
90/90
V or H
5.5
FR90
125
120/120
V or H
5.5
FR120
125
30/30
V or H
7.5
FR30
125
60/60
V or H
6.0
FR60
125
90/90
V or H
5.5
FR90
150
120/120
V or H
7.5
FR120
150
30/30
V or H
7.5
FR30
150
60/60
V or H
7.5
FR60
150
90/90
V or H
7.5
FR90
175
120/120
V or H
7.5
FR120
175
30/30
V or H
7.5
FR30
175
60/60
V or H
7.5
FR60
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
Thickness (mm)
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span (m) 7.5
Grade
Core Material
175
Fire Resistance Integrity/Insulation (min) 90/90
FR90
200
120/120
V or H
7.5
FR120
200
30/30
V or H
7.5
FR30
200
60/60
V or H
7.5
FR60
200
90/90
V or H
7.5
FR90
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
Cert. No.
Note: * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel. Certificate No: 545a to LPS 1208: Issue 2
Rockspan Lite (wall panel) Product Name
Thickness (mm)
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span (m) 3.0
Grade
Core Material
Cert. No.
75
Fire Resistance Integrity/Insulation (min) 30/30
Rockspan Lite (wall panel)
FR30
Mineral fibre
545a/09
75
60/30
V or H
3.0
FR30
100
30/30
V or H
5.5
FR30
100
60/60
V or H
4.5
FR60
100
90/60
V or H
4.0
FR60
125
30/30
V or H
5.5
FR30
125
60/60
V or H
4.5
FR60
125
90/60
V or H
4.0
FR60
150
120/90
V or H
5.0
FR90
150
30/30
V or H
5.5
FR30
150
60/60
V or H
5.5
FR60
150
90/90
V or H
5.0
FR90
175
120/90
V or H
5.0
FR90
175
30/30
V or H
5.5
FR30
175
60/60
V or H
5.5
FR60
175
90/90
V or H
5.0
FR90
200
120/90
V or H
5.0
FR90
200
30/30
V or H
5.5
FR30
200
60/60
V or H
5.5
FR60
200
90/90
V or H
5.0
FR90
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
Note * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel Certificate No: 545a to LPS 1208: Issue 2
20 Nov 2011
49
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Rockspan Ultima (wall panel) Product Name
Thickness (mm)
Wall Panel Orientation (V/H) * V or H
Maximum Unsupported Span (m) 7.5
Grade
Core Material
Cert. No.
150
Fire Resistance Integrity/Insulation (min) 240/240
Rockspan Ultima (wall panel)
FR240
Mineral fibre
545a/10
175
240/240
V or H
7.5
FR240
200
240/240
V or H
7.5
FR240
Mineral fibre Mineral fibre
Note: 1. LPCB ref 545a/10 - Rockspan Ultima 150mm & 175mm thick wall panel joints to be stitched on both internal and external faces using 4.7mm diameter x 20mm long self-tapping screws at 300mm centres, the 200mm panel does not require stitching. * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel. Certificate No: 545a to LPS 1208: Issue 2
Firemaster Wall Ultima (wall panel) Product Name
Thickness (mm)
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span (m) 7.5
Grade
Core Material
Cert. No.
150
Fire Resistance Integrity/Insulation (min) 240/240
Firemaster Wall Ultima (wall panel)
FR240
Mineral fibre
545a/11
175
240/240
V or H
7.5
FR240
200
240/240
V or H
7.5
FR240
Mineral fibre Mineral fibre
Notes: 1. LPBC Ref 545a/11 - Firemaster Wall Ultima wall panel joints to be stitched on both internal and external faces using 4.7mm diameter x 20mm long self-tapping screws at 300mm centres. * Wall panel orientation, vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel. Certificate No: 545a to LPS 1208: Issue 2
Rainspan Product Name
Thickness (mm)
Rainspan Argeton terracotta tile system
Rainspan Linear system
Rainspan Parklex timber veneer system
Rainspan Rockpanel system
50
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span (m) 7.5
Grade
Core Material
Cert. No.
125
Fire Resistance Integrity/Insulation (min) 120/120
FR120
Mineral fibre
545a/13
150
120/120
V or H
7.5
FR120
175
180/180
V or H
7.5
FR180
125
120/120
V or H
7.5
FR120
150
120/120
V or H
7.5
FR120
175
180/180
V or H
7.5
FR120
125
120/120
V or H
7.5
FR120
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
150
120/120
V or H
7.5
FR120
175
180/180
V or H
7.5
FR180
125
120/120
V or H
7.5
FR120
Mineral fibre Mineral fibre Mineral fibre
545a/14
545a/15
545a/16
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
Rainspan Corium brick slip system
Rainspan Generic timber system
Rainspan Clicktile steel tray system
Thickness (mm)
Wall Panel Orientation (V/H)* V or H
Maximum Unsupported Span (m) 7.5
Grade
Core Material
150
Fire Resistance Integrity/Insulation (min) 120/120
FR120
175
180/180
V or H
7.5
FR180
125
120/120
V or H
7.5
FR120
Mineral fibre Mineral fibre Mineral fibre
150
120/120
V or H
7.5
FR120
175
180/180
V or H
7.5
FR180
125
120/120
V or H
7.5
FR120
150
120/120
V or H
7.5
FR120
175
180/180
V or H
7.5
FR180
125
120/120
V or H
7.5
FR120
150
120/120
V or H
7.5
FR120
175
180/180
V or H
7.5
FR180
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
Cert. No.
545a/17
545a/18
545a/19
Mineral fibre Mineral fibre
Notes: 1. LPCB Ref 545a/13 to 545a/19 - Rainspan, the thickness specified relates to the insulated panel thickness only and does not include the facade system depth. * Wall panel orientation, Vertical or Horizontal (V/H), relates to the long joint orientation of the Insulated panel.
Euroclad Limited Wentloog Corporate Park, Wentloog Road, Cardiff CF3 2ER, United Kingdom Tel: +44 (0)2920 790722 • Fax: +44 (0)2920 793149 E-mail: [email protected] • Website: www.euroclad.com Certificate No: 879b to LPS 1208: Issue 2 Product Name
Elite 51 (wall system) Elite 52 (wall system) Elite 53 (wall system) Elite 54 (wall system) Elite 55 (wall system) Elite 56 (wall system) Elite 57 (wall system) Elite 58 (wall system) Elite 60 (wall system)
System Specification Thickness (mm) See note 2
Wall panel orientation (H/V)
Maximum Unsupported Span (m)
V
See note 2
Grade
Core material
Cert. No.
3.0
Fire Resistance (minutes) Integrity / Insulation 240 / 30
FR30
879b/09
V
3.0
240 / 30
FR30
See note 2
V
3.0
240 / 30
FR30
Mineral Wool Mineral Wool Mineral wool
See note 2
V
3.0
240 / 30
FR30
879b/12
See note 2
H
3.0
240 / 30
FR30
See note 2
H
3.0
240 / 30
FR30
See note 2
H
3.0
240 / 30
FR30
See note 2
H
3.0
240 / 30
FR30
See note 2
H
3.0
240 / 30
FR30
Mineral Wool Mineral Wool Mineral Wool Mineral Wool Mineral Wool Mineral Wool
879b/10 879b/11
879b/13 879b/14 879b/15 879b/16 879b/17
Notes
20 Nov 2011
51
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS 1. Elite wall systems must have the sheeting rail spacing at a maximum of 2m & internal liner sheet side lap joints stitched using steel rivets at 300mm centres, the external liner must be fixed to the channels of the spacer system using self-drilling, self-tapping screws at nominal 400mm centres. 2. The minimum permissible stone mineral wool thickness is 180mm, or for systems with horizontally laid external weather sheets where the eurobar spacer rails are vertical and the insulation in the core is supported by additional steel Z- section supports, and with a minimum density of the insulation of 33kg/m³ the minimum insulation thickness can be reduced to 150mm. 3. Please refer to BRE Assessment Report CC248407 for approved alternative spacer systems, internal & external profiles, internal & external profile coatings and insulation cores for the Elite systems 51, 52, 53, 54, 55, 56, 57, 58 & 60.
Hemsec Manufacturing Limited Stoney Lane, Rainhill, Prescot, Merseyside L35 9LL, United Kingdom Tel: +44 (0)151 426 7171 • Fax: +44 (0)151 493 1331 E-mail: [email protected] • Website: www.hemsec.com Certificate No: 558a to LPS 1208: Issue 2
Composite Panels Product Name
Specification Thickness (mm)
Maximum Unsupported span (m)
Wall panel orientation (H/V) (note 1)
Hemsec PIR Firecheck (wall panel)
100 - 200
4.0
100 - 200 100 - 200 100 - 200 175 - 200 175 - 200 175 - 200 175 - 200 100 - 200 175 - 200 175 - 200
Hemsec PIR Firecheck (ceiling panel)
Grade
Core Material
Cert. No.
H
BS 476: Part 22 Fire Resistance (min) Integrity / Insulation 30/30
FR30
PIR
558a/16
4.0 4.0 4.0 4.0 4.0 4.0 7.5 7.5
H V V H H V V -
60/30 30/30 60/30 30/30 60/60 60/60 30/30 60/30
FR30 FR30 FR30 FR30 FR60 FR60 FR30 FR30
PIR PIR PIR PIR PIR PIR PIR PIR
558a/17
4.5 7.5
-
60/60 30/30
FR60 FR30
PIR PIR
Notes: PIR Firecheck panel: 1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. The Hemsec LPS 1208 Model Specification document QCD: 064/1 relating to the PIR Firecheck wall and ceiling panels LPCB ref 558a/16 and 558a/17 contains the critical components and specific stitching requirements needed for achieving LPCB compliant panel systems. Copies of the Model Specification are available on request, plese contact the Hemsec Sales Department. Certificate No: 558a to LPS 1208: Issue 2
Hemsec SIP Firecheck Product Name
Total system thickness (mm)
Fire resistance (min) Integrity
Fire resistance (min) Insulation
Hemsec SIP Firecheck (wall system)
160 to 287
75
75
257.5 329.5
101
101
Load bearing capacity under test conditions 11.67kN per linear metre Not applicable
Max unsupported span (m)
Grading
Core Material
Cert. No.
2.6
FR60
PUR
558a/11
3.0
FR90
PUR
558a/13
Notes: SIP Firecheck system: 1. LPCB Ref. 558a/11 - Hemsec SIP Firecheck panel system consists of rigid polyurethane foam core (125mm - 252mm thick) sandwiched between 15 mm orientated strand boards (OSB-3). The system was clad on the fire exposed face with a single layer of British Gypsum ‘Gyproc’ 12.5mm wall board (outer layer) and a single layer of British Gypsum ‘Gyproc Fireline’ 12.5mm board (inner layer), board layer joints staggered by 600mm and fixed to softwood timber batons at 600mm centres with 3.5mm x 50mm dry wall screws at 300mm centres. A total load of 35kN was applied for the duration of the test to a 3.0m wide test sample.
52
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS 2. LPCB Ref 558a/13 - SIP Firecheck wall system is approved to LPS 1208 as a non load-bearing, non structural built up wall system of the following configuration; Rigid polyurethane foam core (150mm to 222mm thick) sandwiched between 15 mm orientated strand boards (Krono OSB-3), the panel size is 1.2m x 3.0m and installed with 3 metre joints vertical and consisting of 148mm deep x 70mm thick x 3000mm long timber spline joints inserted into 35mm pre-formed rebates in the core insulation, the joints are fixed with adhesive and nail fixings at 100mm centres. The system is clad on the fire exposed face with two layers of British Gypsum wall boards; A single layer of ‘Gyproc’ 12.5mm wall board (outer layer) and a single layer of ‘Gyproc Fireline’ 15mm board (inner layer), with the wall board joints between layers staggered by 600mm and fixed to softwood timber battens 50mm x 50mm spaced at 600mm centres with 3.5mm x 50mm dry wall screws at 300mm centres, the stud cavity is filled with Knauf Rocksilk Universal slab RW33 insulation.
ISOCAB France S.A. Avenue de la Gironde, Z.I. Petite Synthe, 59640 Dunkerque, France Tel: +33 328 29 26 30 • Fax: +33 328 60 11 93 E-mail: [email protected] • Website: www.isocab.be Certificate No: 465b to LPS 1208: Issue 2 Product Name
Specification Thickness (mm)
IND PIR (Wall panel IND PIR (Wall panel)
IND 20 PIR (Ceiling panel) 120 to 300 Decaroc 50 F (Wall panel)
Decaroc 50F (Wall panel) Decaroc 50 F (Ceiling panel)
20 Nov 2011
Wall Panel orientation (HV) (note 1) V V V V V V -
Fire Resistance (min) Integrity/Insulation 6/68 37/37 37/37 37/37 37/37 68/68 42/42
Grade
Core Material
Cert. No.
220 110 120 140 170 200 200
Maximum unsupported span (m) 4.5 4.5 4.5 4.5 4.5 4.5 4.4
FR60 FR30 FR30 FR30 FR30 FR60 FR30
PIR PIR PIR PIR PIR PIR PIR
465b/01
120 to 300
6.0
V
60/60
FR60
844b/01
120 to 300
4.0
H
240/120
FR120
120 to 300
4.0
V
180/120
FR120
120 to 300
4.0
V
240/120
FR120
120 to 300
6.0
H
120/120
FR120
120 to 300
6.0
H
30/30
FR30
120 to 300
6.0
H
60/60
FR60
120 to 300
6.0
V
120/120
FR120
120 to 300
6.0
V
30/30
FR30
120 to 300
6.0
V
90/90
FR90
80 to 120
4.0
H
60/60
FR60
80 to 120
6.0
H
30/30
FR30
120 to 300
4.0
H
180/120
FR120
120 to 300
6.0
H
90/90
FR90
120 to 300
5.0
-
180/120
FR120
120 to 300
6.0
-
120/120
FR120
120 to 300
6.0
-
30/30
FR30
120 to 300
6.0
-
60/60
FR60
120 to 300
6.0
-
90/90
FR90
Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre Mineral Fibre
465b/03
844b/02
53
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Notes: 1) LPCB Refernce No. 844b/02, ceiling panel joints shall be stitched at 500mm centre's on the unexposed face with flat head steel screws.
Isoclad Limited 10 Alder Road, West Chirton North Industrial Estate, North Shields, Tyne & Wear NE29 8SD, United Kingdom Tel: +44 (0)191 258 5052 • Fax: +44 (0)191 259 5742 E-mail: [email protected] • Website: www.isoclad.co.uk Certificate No: 142a to LPS 1208: Issue 2 Product Name
Specification Thickness (mm)
Firestop 10 (wall panel)
Firestop10 (Wall Panel)
Firestop10 (Wall Panel)
54
Wall Panel orientation (H/V) (note 1)
75
Maximum Unsupported Panel Span (m) 3.0
100
Grade
Core Material
Cert. No.
V
Fire Resistance (min) Integrity / Insulation 30 / 30
FR30
142a/01
4.5
V
60 / 60
FR60
100
5.5
V
30 / 30
FR30
125
4.5
V
60 / 60
FR60
125
5.5
V
30 / 30
FR30
150
5.0
V
90 / 90
FR90
150
5.5
V
30 / 30
FR30
150
5.5
V
60 / 60
FR60
175
5.0
V
90 / 90
FR90
175
5.5
V
30 / 30
FR30
175
5.5
V
60 / 60
FR60
200
5.0
V
90 / 90
FR90
200
5.5
V
30 / 30
FR30
200
5.5
V
60 / 60
FR60
100
7.5
H or V
240 / 30
FR30
100
7.5
H or V
240 / 60
FR60
125
7.5
H or V
240 / 30
FR30
125
7.5
H or V
240 / 60
FR60
150
7.5
H or V
240 / 30
FR30
150
7.5
H or V
240 / 60
FR60
175
7.5
H or V
240 / 30
FR30
175
7.5
H or V
240 / 60
FR60
200
7.5
H or V
240 / 30
FR30
200
7.5
H or V
240 / 60
FR60
100
4.35
H
60 / 60
FR60
100
6.0
H
30 / 30
FR30
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre MIneral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
Firestop 12 (wall panel)
Firestop 12C (ceiling panel) Isoclad PIR (Wall panel) Isoclad PIR (Ceiling panel) Isoclad PIR 40 (Wall Panel) Firestop 12 (Ceiling Panel)
20 Nov 2011
Specification Thickness (mm)
Grade
Core Material
H
Fire Resistance (min) Integrity / Insulation 60 / 60
FR60
6.0
H
30 / 30
FR30
150
4.35
H
60 / 60
FR60
150
6.0
H
30 / 30
FR30
175
4.35
H
60 / 60
FR60
175
6.0
H
30 / 30
FR30
200
4.35
H
60 / 60
FR60
200
6.0
H
30 / 30
FR30
75
3.0
V
30 / 30
FR30
75
3.0
V
60 / 60
FR60
100
5.5
V
90 / 90
FR90
100
6.0
V
60 / 60
FR60
100
7.5
V
30 / 30
FR30
125
5.5
V
90 / 90
FR90
125
6.0
V
60 / 60
FR60
125
7.5
V
30 / 30
FR30
150
5.5
V
120 / 120
FR120
150
5.5
V
90 / 90
FR90
150
6.0
V
60 / 60
FR60
150
7.5
V
30 / 30
FR30
175
5.5
V
120 / 120
FR120
175
5.5
V
90 / 90
FR90
175
6.0
V
60 / 60
FR60
175
7.5
V
30 / 30
FR30
200
5.5
V
120 / 120
FR120
200
5.5
V
90 / 90
FR90
200
6.0
V
60 / 60
FR60
200
7.5
V
30 / 30
FR30
100 to 200
3.0
-
60 / 60
FR60
100 to 200
5.5
-
30 / 30
FR30
100 150
3.0 3.4
V -
46 / 41 80 / 50
FR30 FR30
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre PIR PIR
142a/05 142a/06
150
4.0
V
60/30
FR30
PIR
142a/07
150 100
6.0 4.4
V -
30/30 63/63
FR30 FR60
PIR Mineral fibre
142a/08
Wall Panel orientation (H/V) (note 1)
125
Maximum Unsupported Panel Span (m) 4.35
125
Cert. No.
142a/02
142a/03
55
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
Specification Thickness (mm)
Securiclad SR4 (Wall Panel)
Securiclad SR4 (Ceiling Panel)
Grade
Core Material
Cert. No.
V
Fire Resistance (min) Integrity / Insulation 120/90
FR90
142a/09
4.0
V
180/90
FR90
100
4.0
V
240/90
FR90
100
4.0
V
90/90
FR90
100
5.2
V
60/60
FR60
100
7.5
V
30/30
FR30
100
4.1
-
60/60
FR60
100
7.5
-
30/30
FR30
Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre Mineral fibre
Wall Panel orientation (H/V) (note 1)
100
Maximum Unsupported Panel Span (m) 4.0
100
142a/10
Notes: 1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. LPCB Ref No 142a/01 where the Firestop 10 wall panels maximum unsupported span is listed as 7.5m the joints between the panels must be stitched on both internal and external faces with 4mm Ø stainless steel rivets at nominal 200mm centres and be sealed with Hilti CP 606 intumescent sealant on both faces. 3. LPCB ref. No 142a/01 where the Firestop 10 wall panels are listed as installed horizontally (H) only, the joints between the panels are unstitched and sealed with a bead of Geocel Dow Corning Firestop 700 silicone sealant on both joint faces. 4. LPCB Ref. No. 142a/03 The joints on the Firestop12 ceiling panels should be stitched with 3mm diameter rivets at 300mm centres on the internal and external face. 5. LPCB ref. No 142a/05 Isoclad PIR Wall panels shall be stitched with 4.2mm diameter rivets at 150mm centres on the external face. 6. LPCB ref. No 142a/06 Isoclad PIR ceiling panels shall be stitched with 4.2mm diameter rivets at 200mm centres on the internal and external face. 7. LPCB ref. No 142a/07 Isoclad PIR 40 wall palenls, a bead of Hilti CP601 intumescent sealant call be applied to the female joint profile prior to installation then stitched with 4mm diameter rivets at 200mm centres on the internal and external face and sealed with a further bead of Hilti CP 601 intumescent sealant on both faces. 8. LPCB ref No 142a/08, 142a/09 & 142a/10 the joints between the panels are unstitched. A bead of Envirograph 62 intumescent fieproof sealant shall be applied to the female joint profile prior to installation, and sealed with a further bead of Envirograph 62 intumescent fireproof sealant on both faces.
Kingspan Ltd Carrickmacross Road, Kingscourt, Co. Cavan, Ireland Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77 E-mail: [email protected] • Website: www.kingspanpanels.com Certificate No: 186b to LPS 1208: Issue 2 Product Name
Specification Thickness (mm)
Kingspan Ecosafe KS1100CS (wall panel)
100, 125, 150, 175 & 200 100, 125, 150 175 & 200 175 & 200
Kingspan Ecosafe KS1100CS (ceiling panel) Kingspan Ecosafe KS1100CS (wall panel) Kingspan Ecosafe KS1100CS(ceiling panel) Kingspan Ecosafe KS1100CS (wall panel)
Fire Resistance (min) Integrity 195
Fire Resistance (min) Insulation 31
Maximum Unsupported Length (m)
Grade
Core Material
Cert. No.
4.00
FR30
PIR
279b/05
58
32
3.40
FR30
PIR
279b/06
240
64
3.00
FR60
PIR
279b/07
175 & 200
148
67
3.30
FR60
PIR
279b/08
175 & 200
69
61
4.00
FR60
PIR
279b/09
Note: 1. LPCB Ref 279b/05, 279b/06, 279b/07, 279b/08 & 279b/09 Refer to model specification LPCB 11 Rev 1 for full details
56
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS
Kingspan Ltd. Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161 E-mail: [email protected] • Website: www.kingspanpanels.com Certificate No: 260b to LPS 1208: Issue 2 Product Name
Specification Thickness (mm)
Kingspan Ecosafe KS1100CS (wall panel)
100, 125, 150, 175 & 200 100, 125, 150, 175 & 200 175 & 200
Kingspan Ecosafe KS1100CS (ceiling panel) Kingspan Ecosafe KS1100CS (wall panel) Kingspan Ecosafe KS1100CS (ceiling panel) Kingspan Ecosafe KS1100CS (wall panel)
Fire Resistance (min) Integrity 195
Fire Resistance (min) Insulation 31
Maximum Unsupported Length (m)
Grade
Core Material
Cert. No.
4.00
FR30
PIR
279b/05
58
32
3.40
FR30
PIR
279b/06
240
64
3.00
FR60
PIR
279b/07
175 & 200
148
67
3.30
FR60
PIR
279b/08
175 & 200
69
61
4.00
FR60
PIR
279b/09
Note: 1. LPCB Ref 279b/05, 279b/06, 279b/07, 279b/08 & 279b/09 Refer to model specification LPCB 11 Rev 1 for full details.
Modular Panel Systems Limited Mohill, Co.Leitrim, Ireland Tel: +353 719631162 • Fax: +353 719651979 E-mail: [email protected] • Website: www.modular.ie Certificate No: 750a to LPS 1208 Issue 2 Product Name
Specification Thickness (mm)
Enviro Panel PIR (wall panel) Enviro Panel Mineral wool (wall panel) Enviro Panel Mineral wool (ceiling panel) Enviro Panel PIR (wall panel) Enviro Panel Mineral wool (wall panel) Enviro Panel Mineral wool (ceiling panel) Enviro Panel Mineral wool (wall panel)
Fire Resistance (min) Insulation 15 48 48 44
Max Unsupported Length (m)
Grade
Core Material
Cert. No.
100 150 200 100
Fire Resistance (min) Integrity 43 60 60 121
3.0 3.0 3.0 7.5
FR15 FR30 FR30 FR30
PIR PIR PIR Mineral wool
750a/01 750a/02
150
121
68
3.0
FR60
Mineral wool
750a/03
100 150 200 100
30 60 60 120
15 30 30 30
3.0 3.0 3.0 7.5
FR15 FR30 FR30 FR30
PIR PIR PIR Mineral wool
750a/04
150
120
60
3.0
FR60
Mineral wool
750a/06
150
120
60
7.5
FR60
Mineral wool
750a/07
750a/05
Notes: 1. LPCB Ref. 750a/01, 750a/02, 750a/04, 750a/05 & 750a/07 Wall panels shall be installed with the long joint in the vertical orientation.
20 Nov 2011
57
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS 2. LPCB Ref. 750a/01, 750a/03, 750a/04 & 750a/06 - A strip of Pyrostrip graphite self-adhesive tape, 10mm wide x 2mm thick, shall be applied between the overlap in the steel skins of adjacent panels, the joints of the Enviro panels shall then be stitched with 4.8mm dia x 10mm stainless steel rivets @ 300mm centres on both the exposed and internal face. 3. LPCB Ref. 750a/02, 750a/05 & 750a/07 - A strip of Pyrostrip graphite self-adhesive tape, 10mm wide x 2mm thick, shall be applied between the overlap in the steel skins of adjacent panels, the joints of the Enviro panels shall then be stitched with 3.2mm dia x 12mm stainless steel rivets @ 300mm centres on both the external and internal face. 4. LPCB Ref. 750a/01, 750a/02 & 750a/03 PIR and Mineral wool panels are supplied with a castellated joint panel edge profile. 5. LPCB Ref. 750a/04, 750a/05 & 750a/06 PIR and Mineral wool panels are supplied with a flat, butt joint panel edge profile. 6. LPCB Ref. 750a/07 Mineral wool wall panels are supplied with a castellated joint or a flat, butt joint panel edge profile.
Panel Projects Limited Portview Road, Avonmouth, Bristol BS11 9LQ, United Kingdom Tel: +44 (0)117 316 7000 • Fax: +44 (0)117 316 7001 Certificate No: 881a to LPS 1208: Issue 2
Wall Panels Product Name
Specification Thickness (mm)
Fire Resistance Insulation (min) 30
Maximum unsupported span (m)
Grade
Core Material
Cert. No.
100
Fire Resistance Integrity (min) 30
Firecold (wall panels)
6.2
FR30
Mineral wool
881a/01
100 125 125
60 30 60
60 30 60
4.0 6.2 4.0
FR60 FR30 FR60
Mineral wool Mineral wool Mineral wool
Grade
Core Material
Cert. No.
FR30 FR90 FR60 FR30 FR120 FR90 FR60 FR30 FR180 FR120 FR90 FR30 FR60 FR120 FR180 FR240
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
381a/01
Note: 1. LPCB Ref 881a/01 Wall panels to be installed with long joints in the vertical orientation only.
Paroc Panel System Oy Ab FIN-21600, Parainen, Finland Tel: +358 46 876 8000 • Fax: +358 46 876 8702 E-mail: [email protected] • Website: www.paroc.com Certificate No: 381a to LPS 1208: Issue 2
AST F, AST S & AST T Wall Panels and AST E Ceiling Panels Product Name
Specification Thickness (mm)
Maximum Unsupported span (m)
Wall panel orientation (H/V) (note 1)
PAROC AST F (wall panel)
50 80 80 80 100 100 100 100 120 120 120 120 120 100 - 240 120 - 240 150 - 240
4.6 4.0 4.9 7.5 4.0 4.4 6.6 7.5 4.0 4.8 6.4 7.5 7.5 4.0 4.0 4.0
V V V V V V V V V V V V V H H H
58
Fire Resistance (mm) Integrity / Insulation 30/30 90/90 60/60 30/30 120/120 90/90 60/60 30/30 180/180 120/120 90/90 30/30 60/60 120/120 180/180 240/240
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
PAROC AST S (wall panel)
PAROC AST E (ceiling panel) PAROC AST T (wall panel)
Specification Thickness (mm)
Maximum Unsupported span (m)
Wall panel orientation (H/V) (note 1)
150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 50 -240 80 - 240 80 - 240 80 80 100 100 120 120 120 120 100 - 240 120 - 240 120 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 80 - 240 80 - 240 100
4.0 4.7 7.1 7.5 7.5 7.5 4.0 4.0 4.0 4.0 5.1 4.0 6.7 4.0 4.6 6.9 7.5 4.0 4.0 4.0 4.0 4.0 4.0 4.1 6.1 7.5 7.5 7.5 4.0 4.0 6.5
100 80 100 120 120 120 120 120 - 240 120 - 240 120 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 150 - 240 80 - 240
8.2 4.0 5.1 4.0 4.8 7.3 7.5 4.0 4.0 4.0 4.0 4.0 4.0 4.7 7.1 7.5 7.5 7.5 4.0
Grade
Core Material
V V V V V V H H H V V V V V V V V H H H H H V V V V V V H H -
Fire Resistance (mm) Integrity / Insulation 240/240 180/180 120/120 30/30 60/60 90/90 30/30 60/60 90/90 60/30 30/30 60/60 30/30 120/120 90/90 60/60 30/30 60/60 120/120 90/90 180/180 240/240 240/240 180/180 120/120 30/30 60/60 90/90 30/30 60/30 60/60
FR240 FR180 FR120 FR30 FR60 FR90 FR30 FR60 FR90 FR30 FR30 FR60 FR30 FR120 FR90 FR60 FR30 FR60 FR120 FR90 FR180 FR240 FR240 FR180 FR120 FR30 FR60 FR90 FR30 FR30 FR60
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
V V V V V V H H H H H V V V V V V H
30/30 30/30 30/30 120/120 90/90 60/60 30/30 120/120 60/60 90/90 180/180 240/240 240/240 180/180 120/120 30/30 60/60 90/90 30/30
FR30 FR30 FR30 FR120 FR90 FR60 FR30 FR120 FR60 FR90 FR180 FR240 FR240 FR180 FR120 FR30 FR60 FR90 FR30
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
Cert. No.
381a/02
381a/04 381a/05
Notes: 1. Wall orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. LPCB Ref 381a/01, 381a02 and 381a/05 when panels are laid with the long joint in the horizontal orientation the joints shall be stitched on the internal and external face at nominal 150mm centres.
20 Nov 2011
59
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS
Promat UK Ltd The Sterling Centre, Eastern Road, Bracknell, Berkshire RG12 2TD, United Kingdom Tel: +44 (0)1344 381300 • Fax: +44 (0)1344 381301 Website: www.promat.co.uk Certificate No: 545a to LPS 1208: Issue 2 Product Name
Specification Thickness (mm)
Durawall 120 Durawall 90 Durawall 60 Durawall 240
150 125 100 150
Fire Resistance (min) Integrity 120 90 60 240
Fire Resistance (min) Insulation 120 90 60 240
Maximum Unsupported Length (m)
Grading
Core Material
Cert. No.
5.50 5.50 4.50 7.50
FR120 FR90 FR60 FR240
Mineral fibre Mineral fibre Mineral fibre Mineral fibre
545a/01 545a/03 545a/11
Notes: 1. LPCB Ref. No’s 545a/01, 545a/03 and 545a/11 - Wall panels can be installed vertically or horizontally. 2. LPCB Ref. No’s 545a/11 - wall panel joints to be stitched on both internal and external faces using 4.7mm Diameter x 20mm long self-tapping screws at 300mm centres.
Ruukki Construction Oy PO Box 138, (Suolakivenkatu 1), 00811 Helsinki, Finland Tel: +358 20 592 7521 • Fax: +358 20 592 7708 E-mail: [email protected] • Website: www.ruukki.com Certificate No: 660a to LPS 1208: Issue 2 Product Name
Specification Thickness (mm)
Max Unsupported Span (m)
Wall panel orientation (H/V) (note 1)
SPA-E
100 & 125
3.0
100, 125, 150, 175, 200, 230 & 260 150, 175, 200, 230 & 260
SPA-I
SPA-F
60
Grade
Core material
Cert. No.
V or H
Fire resistance (min) Integrity / Insulation 60/60
FR60
660a/03
6.0
V or H
30/30
FR30
3.0
V or H
90/90
FR90
150, 175, 200, 230 & 260
5.0
V or H
60/60
FR60
100 & 125
3.0
V or H
60/60
FR60
150, 175, 200, 230 & 260
5.0
V or H
60/60
FR60
150, 175, 200, 230 & 260
6.0
V or H
30/30
FR30
100
3.0
V
180/120
FR120
100
3.8
H
120/120
FR120
100
4.5
V
120/120
FR120
100
5.1
H
90/90
FR90
100
6.0
V
90/90
FR90
100, 125, 150, 175, 200, 230 & 260 100, 125, 150, 175, 200, 230 & 260
6.0
H or V
30/30
FR30
6.0
H or V
60/60
FR60
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
660a/04
660a/05
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
Specification Thickness (mm)
Max Unsupported Span (m)
Wall panel orientation (H/V) (note 1)
125, 150, 175, 200, 230 & 260 125, 150, 175, 200, 230 & 260 125, 150, 175, 200, 230 & 260 125, 150, 175, 200, 230 & 260 150, 175, 200, 230 & 260
3.0
Grade
Core material
H or V
Fire resistance (min) Integrity / Insulation 240/180
FR180
4.0
H or V
180/180
FR180
6.0
H or V
120/120
FR120
6.0
H or V
90/90
FR90
7.5 (note 2)
H or V
120/120
FR120
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
180/180
FR180
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
240/240
FR240
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
30/30
FR30
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
60/60
FR60
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
90/90
FR90
100
3.0
V
180/120
FR120
100
3.8
H
120/120
FR120
100
4.5
V
120/120
FR120
100
5.1
H
90/90
FR90
100
6.0
V
90/90
FR90
100, 125, 150, 175, 200, 230 & 260 100, 125, 150, 175, 200, 230 & 260 125, 150, 175, 200, 230 & 260 125, 150, 175, 200, 230 & 260 125, 150, 175, 200, 230 & 260 125, 150, 175, 200, 230 & 260 150, 175, 200, 230 & 260
6.0
H or V
30/30
FR30
6.0
H or V
60/60
FR60
3.0
H or V
240/180
FR180
4.0
H or V
180/180
FR180
6.0
H or V
120/120
FR120
6.0
H or V
90/90
FR90
7.5 (note 2)
H or V
120/120
FR120
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
180/180
FR180
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
240/240
FR240
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
30/30
FR30
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
60/60
FR60
150, 175, 200, 230 & 260
7.5 (note 2)
H or V
90/90
FR90
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
SPA-S
Cert. No.
660a/06
Note: 1. Wall panel orientation, Horizontal or Vertical (H/V), relates to the long joint orientation. 2. LPCB Ref No. 660a/05 & 660a/06 where panels are approved with a span of 7.5m the joints must be stitched on both faces at 300mm centers using 4.2mm-diameter flat head screws and then sealed using a Teknosafe 2002-00 intumescent paint.
20 Nov 2011
61
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS
Specialist Panels UK Limited Bolam Business Park, Bassington Drive, Bassington Industrial Estate, Cramlington, Northumberland NE23 8AD, United Kingdom Tel: +44(0) 1670 739116 • Fax: +44(0) 1670 732955 E-mail: [email protected] • Website: www.isowall.org.uk Certificate No: 957a to LPS1208: Issue 2 Product Name
Specification Thickness (mm)
Fire Resistance (min) Integrity
Isowall (wall panel)
100
Max Unsupported Span (m)
Grading
Core Material
Cert. No.
98
Fire Resisitance (min) Insulation 98
4.0
FR90
957a/01
125
120
120
3.0
FR120
150
265
208
3.0
FR120
150
265
208
4.0
FR90
Mineral wool Mineral wool Mineral wool Mineral wool
Grade
Core material
Cert. No.
FR30 FR60 FR30 FR60
Mineral wool Mineral wool Mineral wool Mineral wool
881a/01
Note: 1. LPCB Ref No. 957a/01, Wall panels to be installed with long joints vertically only.
Stancold plc Portview Road, Avonmouth, Bristol BS11 9LQ, United Kingdom Tel: +44 (0)117 316 7000 • Fax: +44 (0)117 316 7001 E-mail: [email protected] • Website: www.stancold.co.uk Certificate No: 600a to LPS 1208: Issue 2
Wall panels Product Name Firecold (wall panels)
Specification Thickness (mm) 100 100 125 125
Fire Resistance Integrity (min) 30 60 30 60
Fire Resistance Insulation (min) 30 60 30 60
Maximum unsupported span (m) 6.2 4.0 6.2 4.0
Note: 1. LPCB Ref 881a/01 Wall panels to be installed with long joints in the vertical orientation only.
62
20 Nov 2011
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS
Trimo d.d Prijatljeva 12, 8210 Trebnje, Slovenija Tel: 00386 73460200 • Fax: 0038 673460127 E-mail: [email protected] • Website: www.trimo.eu UK Supplier Trimo UK Ltd, Unit 4 Willaston House, Crewe Road, Nantwich, Cheshire CW5 6NE, United Kingdom Tel: +44 (0) 1270 665303 • Fax: +44 (0) 1270 664294 E-mail: [email protected] • Website: www.trimo.org.uk
Certificate No: 650a to LPS 1208: Issue 2
Trimotherm Panels Product Name
Specification Thickness (mm)
Trimotherm FTV (wall panel)
20 Nov 2011
Fire Resistance (min) Integrity 30
Fire Resistance (min) Insulation 30
Maximum Unsupported Span (m)
Grade
Core Material
Cert. No.
100
Specification Orientation of Long Edges Horizontal
7.25
FR30
650a/01
100
Horizontal
60
60
7.25
FR60
100
Horizontal
90
90
5.60
FR90
100
Vertical
30
30
7.25
FR30
100
Vertical
60
60
7.25
FR60
100
Vertical
90
90
5.60
FR90
120
Horizontal
30
30
8.00*
FR30
120
Horizontal
60
60
8.00*
FR60
120
Horizontal
90
90
8.00*
FR90
120
Horizontal
120
120
8.00
FR120
120
Vertical
30
30
7.25
FR30
120
Vertical
60
60
7.25
FR60
120
Vertical
90
90
5.60
FR90
120
Vertical
120
120
4.00
FR120
150
Horizontal
30
30
8.00*
FR30
150
Horizontal
60
60
8.00*
FR60
150
Horizontal
90
90
8.00*
FR90
150
Horizontal
120
120
8.00
FR120
150
Horizontal
180
180
4.00
FR180
150
Vertical
30
30
7.25
FR30
150
Vertical
60
60
7.25
FR60
150
Vertical
90
90
6.00
FR90
150
Vertical
120
120
5.5
FR120
150
Vertical
180
180
4.00
FR180
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
63
PART 1: SECTION 2.2 LPS 1208 COMPOSITE CONSTRUCTION ELEMENTS Product Name
Trimotherm FTVH (wall panels)
Trimotherm SNV (ceiling panels)
Specification Thickness (mm)
Fire Resistance (min) Integrity 30
Fire Resistance (min) Insulation 30
Maximum Unsupported Span (m)
Grade
Core Material
200
Specification Orientation of Long Edges Horizontal
8.00*
FR30
200
Horizontal
60
60
8.00*
FR60
200
Horizontal
90
90
8.00*
FR90
200
Horizontal
120
120
8.00
FR120
200
Horizontal
180
180
4.00
FR180
200
Vertical
30
30
7.25
FR30
200
Vertical
60
60
7.25
FR60
200
Vertical
90
90
600
FR90
200
Vertical
120
120
5.00
FR120
200
Vertical
180
180
4.00
FR180
100
Vertical
30
30
6.00
FR30
100
Vertical
30
30
6.00
FR30
100
Vertical
60
60
4.85
FR60
100
Vertical
90
90
4.00
FR90
120
Vertical
30
30
6.00
FR30
120
Vertical
60
60
4.85
FR60
120
Vertical
90
90
4.00
FR90
150
Vertical
30
30
6.00
FR30
150
Vertical
60
60
4.85
FR60
150
Vertical
90
90
4.00
FR90
100
-
98
95
2.00
FR90
120
-
98
95
2.00
FR90
150
-
98
95
2.00
FR90
200
-
98
95
2.00
FR90
Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool Mineral wool
Cert. No.
650a/02
650a/03
Note: 1. LPCB Ref. No. 650a/01 - unsupported spans marked *, span can be extended to 10.4m in respect of the length of the panel in horizontal laid orientation only.
64
20 Nov 2011
PART 1: SECTION 2.3 LPS 1581 EXTERNAL CLADDING SYSTEMS ON A MASONRY SUBSTRATE
LPS 1581 Requirements and tests for LPCB approval of non-load bearing External Thermal Insulated Cladding Systems with rendered finishes (ETICS) or Rain Screen Cladding systems (RSC) applied to the masonry face of a building.
20 Nov 2011
65
PART 1: SECTION 2.3.1 LPS 1581 EXTERNAL THERMAL INSULATED CLADDING (ETICS) ON MASONRY SUBSTRATES
LPS 1581 Requirements and tests for LPCB approval of non-load bearing External Thermal Insulated Cladding Systems with rendered finishes (ETICS) or Rain Screen Cladding systems (RSC) applied to the masonry face of a building The test method used is BS 8414-1:2002 Test method for non-load bearing external cladding systems applied to the face of the building and is representative of an external fire source or fully developed (post-flashover) fire in a room venting through an opening such as a window aperture that exposes the external surfaces of the cladding system to the effects of the impinging flames. The test method determines external and potential internal (within the ETICS system) fire spread and, where a void exists, the extent of fire spread through the void. External Thermal Insulated Composite Systems (ETICS) are systems which are applied to a masonry or concrete leaf, typically comprising of a number of layers including an insulation layer, a reinforcing mesh and external render or pre-formed slips or similar finish.
Dryvit UK Limited Unit 4, Wren Park, Hitchin Road, Shefford, Bedfordshire SG17 5JD, United Kingdom Tel: +44 (0)1462 819555 • Fax: +44 (0)1462 819556 E-mail: [email protected] • Website: www.dryvit.co.uk Certificate No: 784a to LPS 1581: Issue 1 Product Name
External layer detail
Roxsulation S
See Note 1&3
Outsulation & Outsulation Plus
See Note 1&5
Fedderlite Panel system
See Note 1&8
Insulation material type & thickness Mineral wool, thickness range 40-200mm See Note 4 EPS, thickness 50-250mm See Note 6 EPS, thickness range 50-120mm
Cavity type and maximum depth
Firebreak detail
EN 13501-1 Classification
Cert. No.
No cavity
Continuous
No Performance Determined
784a/01
No cavity
See Note 7
B-s2-d0 See Note 1
784a/02
Encapsulated cavity between substrate and rear of Fedderlite panel
See Note 9
B-s2-d0 See Note 1
985a/01
Notes: General. 1. LPCB Ref. No. 784a/01, 784a/02 & 985a/01 - Approved systems consist of Dryvit Genesis base coat, Dryvit Standard Plus reinforcing mesh, with or without Dryvit primer and a Dryvit Quarzputz PMRB, Sandpebble PMRB or Sandpebble Fine PMRB top coat, natural or tinted with a Qpcs value of up to 2.95MJ/kg. LPCB Ref. No. 784a/02 & 985a/01 The stated EN 13501-1 classification is applicable to systems with a PMRB top coat, natural or tinted with a Qpcs value up to 2.63MJ/kg only. 2. Subject to the stated conditions the Roxsulation S system (LPCB Ref. No 784a/01) shall be installed in accordance with the application detail contained within Dryvit document DUK628 (June 2008). Outsulation & Outsulation Plus systems (LPCB Ref. No. 784a/02) shall be installed in accordance with the application detail contained within Dryvit documents DUK204 (21/01/08) and DUK218 (V1 21-2-07) respectively. And the Fedderlite panel system (LPCB Ref. No. 985a/01) shall be installed in accordance with the application detail contained within Dryvit document DUK217 Issue 003 31/01/11 - Fedderlite manufacturing instructions and DUK920 - Fedderlite installation instructions. Roxsulation S - LPCB Ref. No 784a/01 3. The system is approved with or without horizontal expansion joints in the render and insulation layer. 4. The insulation boards are adhesively and mechanically fixed to the substrate with Dryvit Genesis adhesive, ribbon and dab method with a minimum of 8 dabs per full size board, and a minimum of 3 mechanical fixings per board. Outsulation & Outsulation Plus - LPCB Ref. No 784a/02 5. The system is approved with or without horizontal expansion joints in the render and insulation layer.
66
20 Nov 2011
PART 1: SECTION 2.3.1 LPS 1581 EXTERNAL THERMAL INSULATED CLADDING (ETICS) ON MASONRY SUBSTRATES 6. Dryvit EPS insulation boards adhered to the substrate with Dryvit Genesis adhesive. 7. Minimum 100mm high continuous horizontal lamella fire breaks shall be affixed direct to the substrate with continuous band of Dryvit Genesis adhesive. The fire breaks shall be positioned at a maximum of 870mm above openings and a maximum of 3100mm centres between consecutive breaks. Fedderlite - LPCB Ref. No 985a/01 8. Joints between Fedderlite panels are nominally 20mm wide and are filled with a 25mm closed cell polyethylene backer rod to produce a 10mm deep cavity to which an approved silicone sealant is applied. 9. Fire breaks shall be incorporated as follows; a. Horizontal and vertical fire breaks are required around the perimeter of openings (top and sides only), these perimeter fire breaks consist of 100mm wide barrier adhered directly to the substrate with a continuous layer of Dryvit Genesis adhesive and shall be of sufficient thickness to create a tight fit between the panel face and substrate. b. Continuous horizontal cavity fire breaks consist of a 100mm high barrier bonded with Genesis adhesive to the substrate; these shall be positioned at a maximum of 850mm above openings and a maximum of 3320mm between subsequent horizontal breaks and shall be of sufficient thickness to create a tight fit between the panel face and substrate. c. Vertical fire breaks (external corners) consist of 100mm wide barriers located directly behind panels on external corner/edges, these vertical breaks are bonded with Genesis adhesive to the substrate and shall be of sufficient thickness to create a tight fit between the panel face and substrate. d. Vertical fire breaks (joints) consist of a 100mm wide barrier to span the joint, overlapping each panel edge by approximately 40mm, and bonded directly to the substrate with a continuous layer of Dryvit Genesis adhesive.
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022h to LPS 1581: Issue 1 Product Name
External layer detail
RockShield
See Note 1
Insulation material type & thickness (mm) Rockwool thickness range 30150mm See note 2
Cavity type & maximum depth (mm)
Firebrakd detail
EN 13501-1 Classification
Cert. No.
N/A
Continuous
No Performance Determined
022h/01
Notes: 1. LPCB Ref. No. 022h/01 - RockShield base coat with universal reinforcing mesh with a white RockShield Silcoplast topcoat. 2.. LPCB Ref. No. 022h/01 - RockShield insulation boards of nominally 1200mm x 600mm fixed to the masonry substrate using 4-5mm layer of RockShield adhesive mortar, and then mechanically fixed using TI anchors fixed at a rate of 5.56 per m².
Sto Ltd 2 Gordon Avenue, Hillington Park, Glasgow G52 4TG, United Kingdom Tel: +44 (0)141 892 8000 • Fax: +44 (0)141 404 9001 E-mail: [email protected] • Website: www.sto.co.uk Certificate No: 749a to LPS 1581: Issue 2.0
20 Nov 2011
67
PART 1: SECTION 2.3.1 LPS 1581 EXTERNAL THERMAL INSULATED CLADDING (ETICS) ON MASONRY SUBSTRATES Product Name StoTherm Vario M
External layer detail See Note 1a
Insulation material type & thickness (mm) EPS, thickness range 60150mm see Note 2
See Note 1b
EPS, thickness 150mm See Note 2
Cavity type & maximum depth (mm) A cavity of maximum of 10mm is formed between the EPS insulation and masonry substrate A cavity of Maximum of 10mm is formed between the EPS insulation and masonry substrate
Firebreak detail
EN13501-1 Classification
Cert. No.
See Note 3
No Performance Determined
749a/01
See Note 3
No Performance Determined
749a/02
Notes: 1. a. LPCB Ref. No. 749a/01 - StoTherm EPS M Render, StoArmat Novo base coat with Sto Glass fibre Mesh F reinforcing mesh and Sto Stolit K2,0 top coat, natural or tinted with a PCS value of up to 2.36MJ/kg. A Secondary layer of Sto Glass fibre Mesh F reinforcing mesh is also required in any area that may be subject to flame impingement. b. LPCB Ref. No. 749a/02 - StoTherm EPS M Render, StoArmat Novo base coat with Sto Glass fibre Mesh F reinforcing mesh and Sto Stolit K2,0 top coat, natural or tinted with a PCS value of up to 2.36MJ/kg. 2. LPCB Ref. No. 749a/01 & 749a/02 - StoTherm Vario M insulation boards of nominally 500mm x 500mm fixed to a mechanical rail system with PVC interlocking vertical T splines, the mechanical rails shall be fixed to the masonry substrate with Sto-Fixing Screw dowel UEZ8 085 CS fixings (or other suitable fixing ependant on masonry substrate type) at a maximum spacing of 300mm. The drainage cavity between the insulation and the masonry substrate is produced via the Sto aluminium starter track and horizontal PVC rails using Sto plastic shims. 3. LPCB Ref. No. 749a/01 & 749a/02 - Sto Mineral Lamella Firebreak details as follows; a. 200mm high Sto Mineral Lamella fire break along top edge and sides of openings adhered direct to the masonry substrate with additional mechanical fixings(Sto Firebreak Dowel SS with integral head) at 300mm centres through the reinforcing mesh and firebreak into the masonry substrate. b. 200mm high continuous horizontal Sto Mineral Fibre Lamella fire break installed using a continuous layer of StoLevell-Uni adhesive, the fire break is additionally affixed with mechanical fixings (Sto SS fixing screw and washer) at 300mm centres through the reinforcing mesh and firebreak into the masonry substrate. Maximum spacing of continuous fire break; 1500mm above openings and maximum of 3000mm centres between consecutive breaks.
Weber, Saint-Gobain Weber Limited Dickens House, Enterprise Way, Maulden Road, Flitwick, Bedfordshire MK45 5BY, United Kingdom Tel: +44 (0)8703 330070 • Fax: +44 (0)1525 718988 E-mail: [email protected] • Website: www.netweber.co.uk Certificate No: 796a to LPS 1581: Issue 1 Product Name weber.therm XM (MFS)
Specification Thickness (mm) 50 - 170
Insulation Material Fixing Method Mechanical
Maximum Vertical Firebreak Distance (m) Continuous
Grade
Insulation Material
Cert. No.
ETIC-1
Mineral fibre
796a/01
Notes: 1. Ref LPCB Ref. No. 796a/01, Insulation material mechanical fixings minimum of 4 ejotherm plastic head fixings per board and stainless steel fire fixings at 1/m2. 2. Ref LPCB Ref. No. 796a/01, system available without top coat or with 6-8mm thick weber.rend PTC or PTS top coat, finish either scrape texture, dry-dash or primer and synthetic coating.
68
20 Nov 2011
PART 1: SECTION 2.3.2 LPS 1581 RAIN SCREEN CLADDING SYSTEMS (RSC) ON MASONRY SUBSTRATES
LPS 1581 Requirements and tests for LPCB approval of non-load bearing External Thermal Insulated Cladding Systems with rendered finishes (ETICS) or Rain Screen Cladding systems (RSC) applied to the masonry face of a building The test method used is BS 8414-1:2002 Test method for non-load bearing external cladding systems applied to the face of the building and is representative of an external fire source or fully developed (post-flashover) fire in a room venting through an opening such as a window aperture that exposes the external surfaces of the cladding system to the effects of the impinging flames. The test method determines external and potential internal fire spread and, where a void exists, the extent of fire spread through the void. Rain Screen Cladding (RSC) systems are often used for the refurbishment of existing buildings where the insulation component is typically fixed to the original masonry face of the building. The external face of the cladding system is fixed to a supporting rail, so that the external face is spaced away from the insulation layer to form a cavity which may be drained.
Sotech Limited 2 Traynor Way, Whitehouse Business Park, Peterlee, County Durham SR8 2RU, United Kingdom Tel: +44 (0)191 587 2287 • Fax: +44 (0)191 518 0703 E-mail: [email protected] • Website: www.sotech-optima.co.uk Certificate No: 770a to LPS 1581: Issue 2 Product Name
External layer detail
Sotech Optima Rainscreen System
Aluminium cassette See Note 1
Insulation material type & thickness (mm) 75mm mineral fibre. See Note 2
Cavity type and maximum depth (mm) Cavity of maximum 200mm depth between rear of cassette system and face of insulation
Firebreak detail
EN 13501-1 Classification
Cert. No.
See Note 3
No Performance Determined
770a/04
Notes: 1.
LPCB Ref. No. 770a/04 - Sotech Optima Rainscreen cassette system consists of aluminium cassette panels precoated with pvdf to the following scope; Cassette Panel Material Aluminium 1.5mm
Aluminium 2.0mm
Aluminium 3.0mm
Cassette Height (mm) 500 600 750 900 1100 500 600 750 900 1100 500 600 750 900
Max. Single Span* (mm) 1500 1500 1500 1350 1200 1800 1800 1800 1500 1200 1800 1800 1800 1600
* Multiple spans are allowable provided that the intermediate supports are installed at centres not exceeding the maximum single span distances. 2.
LPCB Ref. No. 770a/04 - Insulation consists of Rainscreen Duo-slab Mineral fibre, 75mm thick and affixed through the sheathing board to the SFS with a minimum of one central stainless steel Ejot TID anchor (or similar specification) per slab plus one Ejot DH plastic anchor (or similar specification) at each slab end butt joint.
20 Nov 2011
69
PART 1: SECTION 2.3.2 LPS 1581 RAIN SCREEN CLADDING SYSTEMS (RSC) ON MASONRY SUBSTRATES 3.
70
LPCB Ref. No. 770a/04 - fire breaks consist of a lamella/intumescent strip system located at a maximum height intervals of 2.5m.
20 Nov 2011
PART 1: SECTION 2.4 LPS 1582 EXTERNAL CLADDING SYSTEMS SUPPORTED BY A STRUCTURAL STEELWORK FRAME
LPS 1582 Requirements and tests for LPCB approval of non-load bearing external cladding systems fixed to and supported by a structural steel frame.
20 Nov 2011
71
PART 1: SECTION 2.4.1 LPS 1582 EXTERNAL THERMAL INSULATED CLADDING (ETICS) SUPPORTED BY A STRUCTURAL STEEL FRAME
LPS 1582 Requirements and tests for LPCB approval of non-load bearing external cladding systems fixed to and supported by a structural steel frame. This standard is applicable to non-load bearing external cladding systems, such as curtain walling, glazed elements, infill panels and insulated composite panel systems fixed to and supported by a structural steel frame. The test method used is BS 8414-2: 2005 Test method for non-load bearing external cladding systems fixed to and supported by a structural steel frame, and is intended to represent the action of a fully developed (post flashover) fire in a room venting through an opening such as a window aperture, or an external fire source that exposes the external surfaces of the cladding system to the effects of the impinging flames. The test method determines external and potential internal and fire spread and, where a void exists, the extent of fire spread through the void.
Dryvit UK Limited Unit 4, Wren Park, Hitchin Road, Shefford, Bedfordshire SG17 5JD, United Kingdom Tel: +44 (0)1462 819555 • Fax: +44 (0)1462 819556 E-mail: [email protected] • Website: www.dryvit.co.uk Certificate No: 784b to LPS 1582 Issue 1 Product Name
External layer detail
Insulation material type & thickness
Outsulation & Outsulation Plus
See Note 1& 4
Outsulation Rail
See Note 1& 7
Fedderlite Panel System
See Note 1 & 10
EPS Thickness range 50250mm See Note 5 EPS Thickness range 50250mm See Note 8 EPS Thickness range 50120mm
Frame type & sheathing board See Note 2
Cavity type and maximum depth
Firebreak detail
EN 13501-1 Classification
Cert. No.
No cavity
See Note 6
B-s2-d0 See Note 1
784b/01
See Note 2
Drainage cavity of maximum 15mm depth between sheathing board and fire break Encapsulated Cavity between sheathing board and rear of Fedderlite panel
See Note 9
B-s2-d0 See Note 1
784b/02
See Note 11
B-s2-d0 See Note 1
985b/01
See Note 2
Notes: General. 1. LPCB Ref. No. 784b/01, 784b/02 & 985b/01 - Approved systems consist of Dryvit Genesis base coat, Dryvit Standard Plus reinforcing mesh, with or without Dryvit primer and a Dryvit Quarzputz PMRB, Sandpebble PMRB or Sandpebble Fine PMRB top coat, natural or tinted with a Qpcs value of up to 2.95MJ/kg. The stated EN 13501-1 classification is applicable to systems with a PMRB top coat, natural or tinted with a Qpcs value up to 2.63MJ/kg only. 2. LPCB Ref. No. 784b/01, 784b/02 & 985b/01 - Any galvanised steel frame system, installed between floor slabs, confirmed by structural assessment to maintain the structural stability of the wall system in ambient conditions, and is suitable for the fire performance of the wall when exposed to fire within the building. The studs must have a minimum leg length of 45mm and be spaced at a maximum of 600mm centres (the stud size as tested was 100mm x 45mm x 1.2mm). The frame shall be clad with any sheathing board system suitable for the application on the external (cladding) face of the following generic types:- cement particle board (min. 12mm thick), cement-based calcium silicate board (min. 9mm thick), calcium silicate board (min. 9mm thick) or magnesium oxide board (min. 9mm thick). The system is approved with or without mineral wool insulation within the steel frame stud cavity. The internal face frame shall be clad with any type of gypsum wallboard that ensures that the required reaction-to-fire and fire resistance performance is provided when the wall is exposed to fire within the building. 3. Subject to the stated conditions the Outsulation & Outsulation Plus systems (LPCB Ref. No. 784b/01) shall be installed in accordance with the application detail contained within Dryvit documents DUK204 (21/01/08) and DUK218 (V1 21-2-07) respectively. The Outsulation Rail system (LPCB Ref. No. 784b/02) shall be installed in accordance with the application detail contained within Dryvit document DUK664 (21-08-07) and the Fedderlite panel system (LPCB Ref. No. 985b/01) shall be installed in accordance with the
72
20 Nov 2011
PART 1: SECTION 2.4.1 LPS 1582 EXTERNAL THERMAL INSULATED CLADDING (ETICS) SUPPORTED BY A STRUCTURAL STEEL FRAME application detail contained within Dryvit document DUK217 Issue 003 31/01/11 - Fedderlite manufacturing instructions and DUK920 - Fedderlite installation instructions. See BRE Assessment CC270532 for scope of components and variations. Outsulation & Outsulation Plus - LPCB Ref. No 784b/01 4. The system is approved with or without horizontal expansion joints in the render and insulation layer. 5. Dryvit EPS insulation boards adhered to the sheathing board with Dryvit Genesis adhesive. 6. Minimum 100mm high continuous horizontal lamella fire breaks shall be affixed direct to the sheathing board with continuous band of Dryvit Genesis adhesive. The fire breaks shall be positioned at a maximum of 870mm above openings and a maximum of 3100mm centres between consecutive breaks. Outsulation Rail - LPCB Ref. No 784b/02 7. The system is approved with or without horizontal expansion joints in the render and insulation layer. 8. Dryvit EPS insulation boards fixed to a mechanical PVC ‘T’ spline railing system. The rails are fixed to the sheathing board using packing shims of up to 15mm thick at 300mm centres with suitable fixings to form the drainage cavity. 9. The cavity fire break system and continuous horizontal lamella fire breaks shall be positioned a maximum of 800mm above openings, subsequent fire breaks shall be positioned at each floor slab at a maximum spacing of 3100mm centres. Fedderlite - LPCB Ref. No 985b/01 10. Joints between Fedderlite panels are nominally 20mm wide and are filled with a 25mm closed cell polyethylene backer rod to produce a 10mm deep cavity to which an approved silicone sealant is applied. 11. Fire breaks shall be incorporated as follows; a. Horizontal and vertical fire breaks are required around the perimeter of openings (top and sides only), these perimeter fire breaks consist of 100mm wide barrier adhered directly to the sheathing board with a continuous layer of Dryvit Genesis adhesive and shall be of sufficient thickness to create a tight fit between the panel face and substrate. b. Continuous horizontal cavity fire breaks consist of a 100mm high barrier bonded with Genesis adhesive to the sheathing board; these shall be positioned at a maximum of 850mm above openings and a maximum of 3320mm between subsequent horizontal breaks and shall be of sufficient thickness to create a tight fit between the panel face and substrate. c. Vertical fire breaks (external corners) consist of 100mm wide barriers located directly behind panels on external corner/edges, these vertical breaks are bonded with Genesis adhesive to the sheathing board and shall be of sufficient thickness to create a tight fit between the panel face and substrate. d. Vertical fire breaks (joints) consist of a 100mm wide barrier to span the joint, overlapping each panel edge by approximately 40mm, and bonded directly to the sheathing board with a continuous layer of Dryvit Genesis adhesive.
Sto Ltd 2 Gordon Avenue, Hillington Park, Glasgow G52 4TG, United Kingdom Tel: +44 (0)141 892 8000 • Fax: +44 (0)141 404 9001 E-mail: [email protected] • Website: www.sto.co.uk Certificate No: 749b to LPS 1582: Issue 1.0
20 Nov 2011
73
PART 1: SECTION 2.4.1 LPS 1582 EXTERNAL THERMAL INSULATED CLADDING (ETICS) SUPPORTED BY A STRUCTURAL STEEL FRAME Product Name
External layer detail
StoTherm Vario M
See Note 1
StoTherm Mineral M
See Note 5
Insulation material type & thickness (mm) EPS, thickness range 60150mm See Note 2
Frame type and sheathing board
Mineral fibre, thickness range 60150mm See Note 6
See Note 7
See Note 3
Cavity type & maximum depth (mm) Drainage cavity of maximum 20mm depth between sheathing board and insulation Drainage cavity of maximum 20mm depth between sheathing board and insulation
Firebreak detail
EN13501-1 Classification
Cert. No.
See Note 4
No Performance Determined
749b/01
See Note 8
No Performance Determined
749b/02
Notes: 1. LPCB Ref. No. 749b/01 - StoTherm EPS M Render, StoArmat Novo base coat with Sto Glass fibre Mesh F reinforcing mesh and Sto Stolit K2,0 top coat, natural or tinted with a PCS value of up to 2.36MJ/kg. A Secondary layer of Sto Glass fibre Mesh F reinforcing mesh is also required in any area that may be subject to flame impingement. 2 LPCB Ref. No. 749b/01 - StoTherm Vario M insulation boards of nominally 500mm x 500mm fixed to a mechanical rail system with PVC interlocking vertical T splines, the mechanical rails shall be fixed to the sheathing board with Sto-Screw fixings, CS self-tapping 5.5 x 50mm screw fixings at a maximum spacing of 300mm. The drainage cavity between the insulation and the sheathing board is produced via the Sto aluminium starter track and horizontal PVC rails using Sto plastic shims. 3. METSEC lightweight steel frame installed between floor slabs. The frame is clad with two layers of 12.5mm British Gypsum Gyproc Fireline wallboard on the internal face and 12mm Versapanel sheathing board on the external (cladding) face, the sheathing board is fixed to the stud sections using Euroform EMF 1 5.5 x 50mm fixings at a maximum of 600mm centres. 4. LPCB Ref. No. 749b/01 - StoTherm Mineral M Firebreak details as follows; a. 200mm high Sto Mineral Lamella fire break along top edge and sides of openings adhered direct to the sheathing board with additional mechanical fixings (Sto SS fixing screw and washer) at 300mm centres through the reinforcing mesh and firebreak into the sheathing board. b. 200mm high continuous horizontal Sto Mineral Fibre Lamella fire break installed using Sto 2 part stainless steel Fire Break Rails which are screwed back to the sheathing board with Sto intumescent strip on lower edge rail, the fire break is additionally affixed with mechanical fixings (Sto SS fixing screw and washer) at 300mm centres through the reinforcing mesh and firebreak into the sheathing board. Maximum spacing of continuous fire break; 1500mm above openings and maximum of 2700mm centres between consecutive breaks. 5. LPCB Ref. No. 749b/02 - StoTherm Mineral M Render, StoArmat Classic base coat with Sto glass fibre Mesh F reinforcing mesh and Sto Stolit K2,0 top coat, natural or tinted with a PCS value of up to 2.36MJ/kg. 6. LPCB Ref. No. 749b/02 - StoTherm Mineral M insulation boards of nominally 500mm x 500mm fixed to a mechanical rail system with PVC interlocking vertical T splines, the mechanical rails shall be fixed to the sheathing board with Sto-Screw Rail CS 5.5 x 50 fixings at a maximum spacing of 300mm. The drainage cavity between the insulation and the masonry substrate is produced via the Sto aluminium starter track and horizontal PVC rails using Sto plastic shims. 7. LPCB Ref. No. 749b/02 - METSEC lightweight steel frame installed between floor slabs. The frame is clad with two layers of 12.5mm British Gypsum Gyproc Fireline wallboard on the internal face and 12mm Versapanel sheathing board on the external (cladding) face, the sheathing board is fixed to the stud sections using Euroform EMF 1 5.5 x 50mm fixings at a maximum of 600mm centres. 8. LPCB Ref. No. 749b/02 - StoTherm Mineral M Firebreak details as follows; a. 200mm high Sto Mineral Lamella fire break along top edge and sides of openings adhered direct to the sheathing board. b. 500mm high continuous horizontal Sto Mineral Fibre board fire break installed using Sto 2 part stainless steel Fire Break Rails which are screwed back to the sheathing board with Sto intumescent strip on lower edge rail. Maximum continuous fire break spacing; 1450mm above openings and maximum of 3000mm between consecutive breaks.
74
20 Nov 2011
PART 1: SECTION 2.4.2 LPS 1582 RAIN SCREEN CLADDING SYSTEM (RSC) SUPPORTED BY A STRUCTURAL STEEL FRAME
LPS 1582 Requirements and tests for LPCB approval of non-load bearing external cladding systems fixed to and supported by a structural steel frame. This standard is applicable to non-load bearing external rain screen cladding systems fixed to and supported by a structural steel frame. The test method used is BS 8414-2: 2005 Test method for non-load bearing external cladding systems fixed to and supported by a structural steel frame, and is intended to represent the action of a fully developed (post flashover) fire in a room venting through an opening such as a window aperture, or an external fire source that exposes the external surfaces of the cladding system to the effects of the impinging flames. The test method determines external and potential internal and fire spread and, where a void exists, the extent of fire spread through the void.
Sotech Limited 2 Traynor Way, Whitehouse Business Park, Peterlee, County Durham SR8 2RU, United Kingdom Tel: +44 (0)191 587 2287 • Fax: +44 (0)191 518 0703 E-mail: [email protected] • Website: www.sotech-optima.co.uk Certificate No: 770b to LPS 1582 Issue 1.0 Product Name
External layer detail
Sotech Optima Rainscreen System
Aluminium cassette see Note 1
Notes: 1.
2. 3.
4.
Insulation material type & thickness 100mm mineral fibre see Note 2
Frame type & boarding See Note 3
Cavity type and maximum depth (mm) Cavity of maximum 120mm depth between rear of cassette system and face of insulation
Firebreak detail
EN 13501-1 Classification
Cert. No.
See Note 4
No Performance Determined
770b/01
LPCB Ref. No. 770b/01 - Sotech Optima Rainscreen cassette system consists of aluminium cassette panels precoated with pvdf to the following scope; Cassette Panel Material Cassette Height (mm) Maximum Single Span*(mm) Aluminium 1.5mm 500 1500 600 1500 750 1500 900 1350 1100 1200 Aluminium 2.0mm 500 1800 600 1800 750 1800 900 1500 1100 1200 Aluminium 3.0mm 500 1800 600 1800 750 1800 900 1600 *Multiple spans are allowable provided that the intermediate supports are installed at centres not exceeding the maximum single span distances. LPCB Ref. No. 770b/01 – Insulation consists of Rainscreen Duo-slab Mineral fibre, 100mm thick and affixed through the sheathing board to the SFS with a minimum of one fixing (Ejot 80 SS disc washer T1D-TR2 secured with JT3-D6H screw 5.56.3x147 and HTV-4055 washer) per slab. LPCB Ref. No. 770b/01 – Frame system consists of METSEC SFS 150mm lightweight steel frame stud and track sections installed between floor slabs. External sheathing board; minimum of single layer 12mm Versapanel fixed at 600mm centres. Internal liner; minimum of two layers 12.5mm British Gypsum Gyproc Fireline boards, staggered lay and fixed at 600mm centres. The cavity within the SFS is unfilled. LPCB Ref. No. 770b/01 - Fire breaks consist of a horizontal lamella/intumescent strip system located at a maximum height intervals of 2.5m.
20 Nov 2011
75
PART 1: SECTION 2.5 ROOFING PRODUCTS
The products listed in this section are used as roofing systems where there is a risk of fire as follows; Section 2.5.1 - Protection against fire from outside the building. Section 2.5.2 - Protection against fire form inside the building.
76
20 Nov 2011
PART 1: SECTION 2.5.1 PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING
The products listed in this section are used as roofing systems that offer protection where there is a risk of fire from outside of the building. The products have been tested against either BS 476:Part 3 Fire tests on building materials & structures - external fire exposure roof test or ENV 1187:2002 Test methods for external fire exposure to roofs, in order to ensure that roof covering and its supporting deck act as a protective barrier against fire from the outside of a building. It should be noted that BS 476: Part 3:1958 has been withdrawn, but is still referred to in Approved Document B of the UK Building Regulations. ENV 1187:2002 has been issued as a Draft for Development publication and is of a provisional nature as agreement could not be reached on the publication of an EN. Work is currently being undertaken to develop a Loss Prevention Standard for this product group.
Icopal Limited Barton Dock Road, Stretford, Manchester M32 0YL, United Kingdom Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 865 8433 E-mail: [email protected] • Website: www.icopal.co.uk Certificate No: 572a to BS 476: Part 3: 1958
Firesmart Product Name Firesmart Proflex system Firesmart Power system Firesmart Tecnotorch system Firesmart Profiles XL system Firesmart Thermaweld
Category EXT.F.AA EXT.F.AA EXT.F.AA EXT.F.AA EXT.F.AA
Cert. No. 572a/01 572a/03 572a/05 572a/07 572a/09
Notes: 1. The categories specified are applicable only to roofs having a pitch of 10 degrees or less. 2. All products were tested using a 19mm exterior grade plywood deck. Certificate No: 572b to ENV 1187: 2002 Test 1
ENV 1187: 2002 Test 1 Product Name Firesmart Proflex system Firesmart Power system Firesmart Tecnotorch system Firesmart Profiles XL system Firesmart Thermaweld
Category EXT.F.AA EXT.F.AA EXT.F.AA EXT.F.AA EXT.F.AA
Cert. No. 572b/01 572b/03 572b/05 572b/07 572b/09
Notes: 1. The certification applies to roofs with a pitch of 20 degrees or less. 2. The certification for 572b/01, 572b/03, 572b/07 and 572b/09 covers the systems when applied to any wooden continuous deck with a minimum thickness of 16mm, and with gaps not exceeding 0.5mm and any non-combustible continuous deck with a minimum thickness of 10mm. 3. The certification for 572b/05 covers the systems when applied to a 19mm thick exterior grade plywood deck only. 4. The performance of the systems is detailed in the following tables.
20 Nov 2011
77
PART 1: SECTION 2.5.1 PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING Firesmart Prof lex
Firesmart Prof iles XL Firesmart Tecnat orch
Firesmart Power Specimen
Firesmart Thermaweld
1
2
3
4
1
2
3
4
1
2
3
4
10cm
-
-
-
-
-
-
-
-
-
-
-
-
30cm
-
-
-
-
-
-
-
-
-
-
-
-
50cm
-
-
-
-
-
-
-
-
-
-
-
-
Ext er nal f i r e sp r ead
Time t aken t o t ravel: (in an upwards direct ion f rom upper edge of the brand) (min:sec)
70cm
-
-
-
-
-
-
-
-
-
-
-
-
t o upper edge of measuring zone
-
-
-
-
-
-
-
-
-
-
-
-
10cm
3:29
-
2:33
2:19
2:59
-
2:57
2:06
-
-
-
-
30cm
-
-
-
-
-
-
-
-
-
-
-
-
50cm
-
-
-
-
-
-
-
-
-
-
-
-
t o lower edge of measuring zone
-
-
-
-
-
-
-
-
-
-
-
-
Time of occurrence (min:sec)
-
-
-
-
-
-
-
-
-
-
-
-
Length of t ime burning on f loor (min:sec)
-
-
-
-
-
-
-
-
-
-
-
-
0
0
0
0
0
0
0
0
0
0
0
0
Time t aken t o t ravel: (in a downwards direct ion f rom lower edge of the brand) (min:sec)
F all i ng f l aming mat er i al f r o m sur f ace o f r o o f
B ur nt l eng t h ( ext er nal ) Up wards (cm) Downwards (cm)
19
5
21
11
12
5
13
14
6
7
6
7
Damaged area (cm2 )
548
698
554
587
650
697
576
647
645
574
601
557
Firesmart Prof lex
Firesmart Prof iles XL Firesmart Tecnat orch
Firesmart Power Specimen
Firesmart Thermaweld
1
2
3
4
1
2
3
4
1
2
3
4
Time of occurrence (min:sec)
-
-
-
-
-
-
-
-
-
-
-
-
Lengt h of time burning on floor (min:sec)
-
-
-
-
-
-
-
-
-
-
-
-
Time of occurrence (min:sec)
-
-
-
-
-
-
-
-
-
-
-
-
F i r e p enet r at io n
Falling f laming mat erial f rom underside:
Openings
Fire penet rat ion
78
Nat ure
-
-
-
-
-
-
-
-
-
-
-
-
M aximum area of a single opening (cm2)
-
-
-
-
-
-
-
-
-
-
-
-
Sum of area of all openings (cm2)
-
-
-
-
-
-
-
-
-
-
-
-
Time of occurrence (min:sec)
-
-
-
-
-
-
-
-
-
-
-
-
Nat ure
-
-
-
-
-
-
-
-
-
-
-
-
20 Nov 2011
PART 1: SECTION 2.5.1 PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING Firesmart Prof iles XL
Firesmart Prof lex Firesmart Tecnat orch
Firesmart Thermaweld
Firesmart Power Specimen
1
2
3
4
1
2
3
4
1
2
3
4
Nat ure
-
-
-
-
-
-
-
-
-
-
-
-
Up wards
0
0
0
0
0
0
0
0
0
0
0
0
Downwards
19
5
21
11
12
5
13
14
6
7
6
7
Up wards
0
0
0
0
0
0
0
0
0
0
0
0
Downwards
19
5
21
11
12
5
13
14
6
7
6
7
Up wards
0
0
0
0
0
0
0
0
0
0
0
0
Downwards
19
5
21
11
12
5
13
14
6
7
6
7
Up wards
0
0
0
0
0
0
0
0
0
0
0
0
Downwards
19
5
21
11
12
5
13
14
0
0
0
0
I nt er nal d amag e Non-f laming propogat ion
Ext ent of internal damage (cm2)
Layer 1:
Layer 2:
M aximum lengt h of burnt mat erial in each funct ional layer (cm2)
Layer 3:
Layer 4:
Damaged area of each f unct io nal layer (cm2)
Up wards
0
0
0
0
0
0
0
0
N/ A
N/ A
N/ A
N/A
Downwards
0
0
0
0
0
0
0
0
N/ A
N/ A
N/ A
N/A
Layer 1
548
698
554
587
650
697
576
647
645
574
601
587
Layer 2
548
698
554
587
650
697
576
647
645
574
601
587
Layer 3
548
698
554
587
650
697
576
647
98
288
82
159
Layer 4
200
181
246
210
212
70
276
481
N/ A
N/ A
N/ A
N/A
Ext ent o f lat er al f l ame sp r ead External (cm)
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Int ernal (cm)
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
Nil
IKO PLC Appley Lane North, Appley Bridge, Wigan, Lancashire WN6 9AB, United Kingdom Tel: +44 (0)844 412 7207 • Fax: +44 (0)844 412 7208 E-mail: [email protected] • Website: www.ikogroup.co.uk Certificate No: 626a to BS 476: Part 3: 1958
Roofing Products Product Name Coolbond FireBLOC System Superflex FireBLOC system Superflex FireBLOC T-O system
20 Nov 2011
Category EXT.F.AA EXT.F.AA EXT.F.AA
Cert. No. 626a/01 626a/06 626a/07
79
PART 1: SECTION 2.5.1 PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING Product Name Ultra prevENt system Ultra prevENt T-O system Goldseal FR Roofing System Goldseal Torch On Roofing System Mach One Single Layer (Cold Adhered) Roofing System Mach One Single Layer (Mechanically Fixed) Roofing System
Category EXT.F.AA EXT.F.AA EXT.F.AA EXT.F.AA EXT.F.AA EXT.F.AA
Cert. No. 626a/08 626a/10 626a/11 626a/12 626a/14 626a-13
Notes: 1. All systems specified are applicable only to roofs having a pitch of 10 degrees or less. 2. All systems specified were tested applied to an 18mm exterior grade plywood deck. 3. The supporting substrate may be reinforced (cast insitu) concrete 200mm or pre cast concrete slabs, (screeded), 50-100 mm screeded Woodwool slabs, profiled metal decking or 20mm timber boards. 4. Systems LPCB Ref. No. 626a/07 Superflex FireBLOC T-O consist of any IKO VCL, Insulation layers Supertherm Universal (53103mm), or Supertherm PIR (50-100mm), or SuperRock standard (100-160mm) and IKO Systems T-O underlay. 5. Systems LPCB Ref. No. 626a/06 Superflex FireBLOC consist of any Superbar FireBLOC VCL, Insulation layers Supertherm Universal (53-103mm), or Enertherm PIR (50-100mm), or SuperRock standard (100-160mm) and Superbase FireBLOC underlay. 6. Systems LPCB Ref. No. 626a/08 Ultra prevENt consist of any IKO Systems VCL, Insulation layers Supertherm Universal (53103mm), or Enertherm PIR (50-100mm), or SuperRock standard (100-160mm) and UltraprevENt underlay. 7. Systems LPCB Ref. No. 626a/10 Ultra prevENt T-O consist of any Superbar FireBLOC VCL, Insulation layers Supertherm Universal (53-103mm), or Supertherm PIR (50-100mm), or SuperRock standard (100-160mm) and Ultra prevENt T-O underlay. 8. The requirements for BS476: Part 3: 1958 will cease when the UK Building Regulations cease to refer to it. Certificate No: 626b to DD ENV 1187: 2002 - Test Methods for External Fire Exposure to Roofs - Test 1
Roofing Products Product Name Coolbond FireBLOC system
Cert. No. 626b/01
Notes: 1. The certification applies to roofs with a pitch of 20 degrees or greater. 2. The certification covers the above systems when applied to a 18mm thick exterior grade plywood deck. 3. The performance of the systems is detailed in the following table.
Coolbond FireBLOC system Specimen
1
2
3
4
10cm 30cm 50cm 70cm
_ _ _ _
_ _ _ _
5:59 _ _ _
_ _ _ _
to upper edge of measuring zone
_
_
_
_
10cm 30cm 50cm
1:56 2:30 _
1:25 2:17 _
1:49 2:28 _
1:54 5:05_
to low er edge of measuring zone
_
_
_
_
Falling flaming m ate rial from surface of roof (min:sec) Time of occurrence
-
-
-
-
Length of time burning on floor (min: sec)
-
-
-
-
Exte rnal fire spread Time taken to travel: (in an upw ards direction from upper edge of the brand) (min:sec)
Time taken to travel: (in a dow nw ards direction from low er edge of the brand) (min:sec)
Burnt length (exte rnal)
80
Upw ards (cm)
2
3
10
0
Dow nw ards (cm)
30
30
30
30
Damaged area (cm2)
700
600
700
800
20 Nov 2011
PART 1: SECTION 2.5.1 PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING
Specimen Fire penetration Time of occurrence (min:sec)
Falling flaming material from underside:
Coolbond FireBLOC system 1 2
3
4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Length of time burning on floor (min:sec) Time of occurrence (min:sec) Nature Maximum area of a single opening (cm2)
Sum of area of all openings (cm2)
Openings Time of occurrence (min:sec) Nature Fire penetration
20 Nov 2011
81
PART 1: SECTION 2.5.1 PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING Coolbond FireBLOC system Specimen
1
2
3
4
Internal damage Non-flaming propagation Extent of
Nature
_
_
_
_
Upwards
_
_
_
_
internal damage (cm)
Downwards
19
18
28
27
Layer 1: Upwards Downwards
_ 19
_ 18
_ 28
_ 27
_ 8
_ 18
_ 16
_ 27
Layer 3: Updwards Downwards
_ 8
_ 5
_ 5
_ 16
Layer 1
700
500
700
700
Layer 2
500
500
600
700
Layer 3
400
500
500
600
External (cm)
Nil
Nil
Nil
Nil
Internal (cm)
Nil
Nil
Nil
Nil
Maximum length Layer 2: of burnt material Upwards in each functional Downwards layer (cm)
Damaged area of each functional layer (cm2)
Extent of lateral flame spread
Certificate No: 626c to DD ENV 1187: 2002 Test 2
Roofing Products Product Name Coolbond FireBLOC system
Cert. No. 626c/01
Notes: 1) The certification applies to roofs with any pitch. 2) The certification covers the above systems when applied to a 18mm thick exterior grade plywood deck. 3) The performance of the systems is detailed in the following tables. 626c/01 Coolbond FireBLOC system
Specimen 1 Air velocity 2 m/s Time at which specimen ignited 00:54 (min:sec) Time at which flaming of specimen 08:53 ceased (min:sec) Time at which glowing of specimen N/A ceased (min:sec) Test termination time (min:sec) 15:00 Reason for termination (if applicable) N/A 360 Extent of damage to roof covering (mm) Extent of damage to substrate (mm) 0 Damaged area of roof covering (mm2) 31000 Damaged area of substrate (mm2) 0 Maximum depth of damage (mm) 3
82
2 2 m/s 00:51
3 2 m/s 00:50
4 4 m/s 00:48
5 4 m/s 00:38
6 4 m/s 00:41
Average N/A 00:47
08:49
04:29
04:56
04:15
04:10
05:55
N/A
N/A
N/A
N/A
N/A
-
15:00 N/A 360 0 31000 0 3
15:00 N/A 410 0 36000 0 3
15:00 N/A 385 0 34000 0 3
15:00 N/A 390 0 34500 0 3
15:00 N/A 360 0 32000 0 3
15:00 378 0 33084 0 3
20 Nov 2011
PART 1: SECTION 2.5.1 PROTECTION AGAINST FIRE FROM OUTSIDE THE BUILDING
Permanite Asphalt Cawdor Quarry, Matlock, Derbyshire DE4 2JH, United Kingdom Tel: +44 (0)1629 582213 • Fax: +44 (0)1629 583375 E-mail: [email protected] • Website: www.permanite.com Certificate No: 666a to BS 476: Part 3: 1958
Permaphalt Product Name Permaphalt
Category Category EXT.F.AA
Cert. No. 666a/01
Notes: 1. 2. 3. 4. 5.
The Categories specified are applicable only to roofs having a pitch of 10 degrees or less. The test specimen had 2 layers of Permaphalt to a total thickness of 20mm. The product was tested separately with 90mm thick Supertherm PIR and 135mm thick Rockwool HD insulation board. All tests used a 18mm exterior grade plywood deck. The requirement for BS476: Part 3: 1958 will cease when the Building Regulations cease to refer to it.
20 Nov 2011
83
PART 1: SECTION 2.5.2 PROTECTION AGAINST FIRE FROM INSIDE THE BUILDING
The products listed in this section are built-up roofing systems which offer protection against the risk of fire from within the building. The products have been tested to: or or or
BS 476:Part 21 Fire tests on building materials & structures. Methods for determination of the fire resistance of loadbearing elements of construction BS 476:Part 22 Fire tests on building materials & structures. Methods for determination of the fire resistance of non-loadbearing elements EN 1364:Part 2 Fire resistance tests for non-loadbearing elements. Ceilings EN 1365:Part 2 Fire resistance tests for loadbearing elements. Floors & roofs and meet the requirements of LPS 1208 for fire resistance (For roof sandwich panels, see Section 2.2.)
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022a to BS 476: Part 21: Method 7 (see note 1) Product Name
Hardrock DD roofing board Hardrock DD SPA roofing board DuoRock roofing board
Specification System Thickness (mm) (1) 210 100 - 135 140 - 205 210 100 - 135 140 - 205 100 - 210
Fire Resistance (min) Integrity 120 60 90 120 60 90 60
Fire Resistance (min) Insulation 120 60 90 120 60 90 60
Core Material
Cert. No.
Stone Wool Stone Wool Stone Wool Stone Wool Stone Wool Stone Wool Stone Wool
022a/01 022a/02 022a/03
Note: 1. Roof board system LPCB Ref No. 022a/01 & LPCB Ref No. 022a/03: Mechanically fastened Sarnafil single ply type S327-12EL (1.2mm thickness), external weather proof membrane (or alternative membrane less than 3.5 kg/m² e.g. PVC, Chlorinated PE, Butyl Rubber with welded seams); Comprising of two layers of Rockwool roofing board with staggered joints (100mm minimum stagger for fire resistance up to 90 minutes and 300mm stagger for 2 hours fire resistance), vapour control layer and 0.7mm thickness 35mm deep profile steel metal deck. Roof board system LPCB Ref No. 022a/02: Sarnafil single ply external weather proof membrane type G410-12EL (1.2mm thickness), fully adhered to Hardrock DD SPA roof board system with Sarnifil Adhesive(or Rockwool approved alternative adhesive/membrane combination, with a membrane material less than 3.5 kg/m² e.g. PVC, Chlorinated PE, Butyl Rubber with welded seams); comprising of two layers of Rockwool roofing board with staggered joints (100mm minimum stagger for fire resistance up to 90 minutes and 300mm stagger for 2 hours fire resistance), vapour control layer and 0.7mm thickness 35mm deep profile steel metal deck. The test construction was tested unloaded. However, deflection of the roof did not exceed the allowable limits set out in BS 476: Part 20: 1987 for loadbearing horizontal elements. Decking side laps were stitched at 450mm centres. Roof Board System LPCB Ref No 022a/01, 022a/02 & 022a/03 Hardrock DD, Hardrock DD SPA and DuoRock roofing boards are also available and approved in cut-to-fall tapered options, the relevant minimum & maximum system thickness and staggered joints shall apply as detailed above.
84
20 Nov 2011
PART 1: SECTION 2.6 REACTION TO FIRE (RTF) CLASSIFICATIONS FOR MATERIALS AND PRODUCTS
The materials and products listed in this section are LPCB approved and classified to one of the following Reaction to Fire (RTF) classification systems:
Non-combustible to BS 476-4 Fire tests on building materials and structures. Non-combustibility test for materials.
Class O as defined in Approved Document B - Fire Safety, The Building Regulations 2000.
BS EN 13501-1 Fire classification of construction products and building elements. Classification using test data from reaction to fire tests. Note: LPCB approvals under this standard are limited to materials or products resulting in a classification of A1, A2 or B. Products under A2 or B will also be classified in relation to the additional classifications of s and d (eg s3, d2).
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022e to EN 13501-1: 2002
Rockwool Non-combustible Insulation Materials Product Name Cladding Roll - Aluminium Foil Faced Cladding Roll - Unfaced Cladding Roll - White Tissue Faced Cavity Batts - Unfaced Rainscreen Duo Slabs - Black Tissue Faced Rainscreen Duo Slabs - Unfaced Flexi Batts - Unfaced Hardrock Dual Density Roofing Boards - Black Tissue Faced Hardrock Dual Density Roofing Boards - Unfaced Hardrock Dual Density Roofing Boards - White Tissue Faced DuoRock Roofing Boards - Black Tissue Faced DuoRock Roofing Boards - Unfaced DuoRock Roofing Boards - White Tissue Faced
Thickness (mm) 60 - 180 60 - 180 60 - 180 50 - 150 50 - 125 50 -125 50 - 150 50 - 155
Test/Assessment Standard EN 13501-1: 2002 EN 13501-1: 2002 EN 13501-1: 2002 EN 13501-1: 2002 EN 13501-1: 2002 EN 13501-1: 2002 EN 13501-1: 2002 EN 13501-1: 2002
Classification
50 - 155 50 - 155
EN 13501-1: 2002 EN 13501-1: 2002
A1 A1
50 - 180 50 - 180 50 - 180
EN 13501-1: 2002 EN 13501-1: 2002 EN 13501-1: 2002
A1 A1 A1
A1 A1 A1 A1 A1 A1 A1 A1
Cert. No. 022e/01 022e/02 022e/03 022e/04 022e/05
022e/06
Superglass Insulation Limited Thistle Industrial Estate, Kerse Road, Stirling FK7 7RW, United Kingdom Tel: +44 (0)1786 451170 • Fax: +44 (0)1786 451245 E-mail: [email protected] • Website: www.superglass.co.uk Certificate No: 472a to BS 476: Part 4
Thermaquilt and Superglass Cladding Mat Product Name Thermaquilt Superglass Cladding Mat
20 Nov 2011
Thickness (mm) 50 - 200 60 - 200
Test/Assessment Standard BS 476:Part 4 BS 476:Part 4
Classification
Cert. No.
Non-combustible Non-combustible
472a/01 472a/02
85
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS
The following products have been approved to LPS 1132 Requirements and tests for LPCB approval of wall & floor penetration & linear gap seals to help ensure fire resisting compartment walls and floors are not compromised by the installation of building services that pass between fire resisting compartments. The design requirements for these products are described in more detail in Section 4.6 of the LPC Design Guide for the Fire Protection of Buildings: 2000.
DST Group Ltd Design House, 2C Southgate, White Lund, Morecombe, Lancs LA3 3PB, United Kingdom Tel: +44 (0)1524 389494 • Fax: +44 (0)1524 389495 E-mail: [email protected] • Website: www.dstgroup.co.uk Certificate No: 873a to LPS 1132: Issue 4.1
Fire Sleeve Pipe Wraps Product Name
Use
Element of construction
Fire Sleeve Pipe Wraps
uPVC Pipes up to 167mm diameter uPVC Pipes from 167mm to 225mm diameter ABS pipes up to 114mm diameter Polypropylene pipes up to 16mm diameter Polypropylene pipes from 16mm to 160 mm diameter Polypropylene pipes from 160mm to 225mm diameter Polyethylene pipes up to 225mm diameter Steel pipes up to 220mm diameter Copper pipes up to 76mm diameter
Concrete, masonry or drywall Concrete, masonry or drywall Concrete, masonry or drywall Concrete, masonry or drywall Concrete, masonry or drywall Concrete, masonry or drywall Concrete, masonry or drywall Concrete, masonry or drywall Concrete, masonry or drywall
Element of construction thickness minimum (mm) 130
Fire resistance (min) Integrity
Fire resistance (min) Insulation
Cert. No.
120
Not assessed
873a/01
130
120
Not assessed
130
120
Not assessed
130
120
Not assessed
130
90
Not assessed
130
60
Not assessed
130
120
Not assessed
130
120
Not assessed
130
120
Not assessed
Note: The fire performance of the system will be dependent on the diameter and wall thickness of the pipe and installed location as detailed in the tables above. The shell of the pipe wrap assembly shall be sealed in the element of construction by a bead of DST Group intumescent mastic/sealant with a minimum fire rating of 2 hours. Reference should be made to manufacturers’ literature and BRE Global assessment report CC241402 for further information
Hilti Aktiengesellschaft Feldkircher Strasse 100, Postfach 333, FL-9494 Schaan, Liechtenstein Tel: +423 234 3004 • Fax: +423 234 2674 E-mail: [email protected] • Website: www.hilti.com UK Sales: Hilti (G.B.) Limited 1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY, United Kingdom Tel: +44 (0)161 886 1000 • Fax: +44 (0)161 786 3890
Certificate No: 090a(3) to LPS 1132: Issue 4
86
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS CP 611A - LPCB Ref. No.: 090a(3) Product Name
CP 611A
Element of construction orientation
Element of construction thickness (mm)
Element of construction material
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Use Cables
Wall
100+
Drywall
25mm CP611A
No filling
30mm CP611A
Yes
No
No
Fire Resistance (min) Integrity / Insulation 120 / 60
Wall / Floor
110+
50mm CP611A
N/A
Yes
No
30 / 30
150+
50mm CP611A
Yes
Yes
No
90 / 60
Wall / Floor
150+
10mm CP611A
Yes
No
No
240 / 90
Wall / Floor
150+
30mm CP611A
Yes
No
No
240 / 30
Wall / Floor
150+
20mm CP611A
Yes
No
No
240 / 30
Wall / Floor
150+
50mm rockwool 130mm rockwool 90mm rockwool 110mm rockwool N/A
60mm rockwool 50mm CP611A
Yes
Wall / Floor
40mm CP611A
Yes
Yes
No
120 / 90
Wall / Floor
150+
N/A
110mm rockwool
Yes
Yes
No
120 / 90
Wall
100+
LW Concrete LW Concrete LW Concrete LW Concrete LW Concrete LW Concrete Reinforced vermiculite concrete LW Concrete
60mm CP611A
N/A
N/A
No
No
240 / 240
Wall
100+
LW Concrete
N/A
N/A
60mm CP 611A
No
No
Floor
120+
80mm CP611A
N/A
N/A
No
No
Floor
120+
Reinforced autoclaved aerated concrete slabs minimum density 670kg/m³ Reinforced autoclaved aerated concrete slabs minimum density 670kg/m³
PVC pipe 40mm Ø x3mm thick PVC pipe 40mm Ø x3mm thick PVC pipe 40mm Ø x3mm thick
N/A
N/A
80mm CP611A
No
No
10mm CP611A 30mm CP611A 20mm CP611A 110mm rockwool 40mm CP611A
Use Trays
Use Pipes
PVC pipe 40mm Ø x3mm thick
Cert. No.
090a/01
240 / 240
180 / 120
180 / 180
Note: Please refer to installation instructions for further details. Certificate No: 090a(2) to LPS 1132: Issue 4
CP 636 - LPCB Ref. No.: 090a(2) Product Name
Element of construction orientation
Element of construction thickness/material
CP 636
Floor
150mm+ Aerated Concrete 150mm+ Aerated Concrete
Floor
Configuration: fire side
Configuration: non-fire side
Use: cables
Use: trays
Use: conduit pipes
Aperture Size (mm)
N/A
150mm CP636
Yes
Yes
Yes
1000x600
Fire Resistance (min) Integrity (E) 180
Fire Resistance (min) Insulation (I) 90
75mm CP636
Yes
Yes
No
600x600
240
90
Wall
150mm+ Masonry
50mm mineral fibre 3 (140kg/m ) N/A
150mm CP636
Yes
Yes
Yes
2000x1200
20
120
Wall
120mm+ Masonry
N/A
100mm CP636
Yes
Yes
No
600x600
240*
60*
Wall
200mm+ Masonry
N/A
185mm CP636
Yes
Yes
Yes
1200x600
240
60
Cert. No.
532a/01
Note: * To achieve this fire resistance the penetrations should be coated with a 30mm wide x 0.5mm thick layer of Hilti CP611A where they pass through the wall. The coated section should be positioned centrally within the wall thickness. Certificate No: 090a(1) to LPS 1132: Issue 4
20 Nov 2011
87
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS CP 601S - LPCB Ref. No.: 090a(1) Product Name
Element of construction orientation
Element of construction thickness (mm)
Element of construction material
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Use
CP 601S
Floor
150+
L W Concrete
20mm CP601S
110mm mineral fibre (100kg/m3)
20mm CP601S
Floor
150+
L W Concrete
20mm CP601S
110mm mineral fibre (100kg/m3)
20mm CP601S
Floor
150+
L W Concrete
20mm CP601S
110mm mineral fibre (100kg/m3)
20mm CP601S
Wall
100+
L W Concrete
20mm CP601S
60mm mineral fibre (100kg/m3)
20mm CP601S
Wall
100+
L W Concrete
20mm CP601S
60mm mineral fibre 3 (100kg/m )
20mm CP601S
Wall
100+
L W Concrete
20mm CP601S
60mm mineral fibre (100kg/m3)
20mm CP601S
Copper pipes 42200mm dia. 1.2510.0mm wall Copper pipes 42200mm dia. 1.2510.0mm wall Copper pipes 4250mm dia. 1.2510.0mm wall Copper pipes 42200mm dia. 1.2510.0mm wall Copper pipes 42200mm dia. 1.2510.0mm wall Copper pipes 4250mm dia. 1.2510.0mm wall
Fire Resistance (min) Integrity (E) 120
Fire Resistance (min) Insulation (I) 0
240
0
240
0
120
0
240
0
240
0
Cert. No.
520a/01
Note: 1. Product used as a pipe penetration sealant. Certificate No: 090a(1) to LPS 1132: Issue 4
CP 601S - LPCB Ref. No.: 090a(1) Product Name
Element of construction orientation
Element of construction thickness (mm)
Element of construction material
CP 601S
Floor
150+
L W concrete
88
Dept of CP620 (mm) (notes 2 & 5) 15
Fire Side
Penetration Size (notes 1, 3, 4)
Non-Fire Side
N/A
144mm mineral fibre (100kg/m3) 135mm mineral fibre (100kg/m3) 135mm mineral fibre (100kg/m3) 70mm mineral fibre (100kg/m3) 12mm dia PE rod 50mm dia. PE rod 15mm dia. PE rod 35mm dia. PE rod 15mm dia. PE rod 50mm dia. PE rod 15mm dia. PE rod
6mm CP601S 15mm CP601S 15mm CP601S 15mm CP601S 10mm CP601S 20mm CP601S 6mm CP601S 15mm CP601S 6mm CP601S 20mm CP601S 6mm CP601S
35mm dia. PE rod 15mm dia. PE rod
15mm CP601S 6mm CP601S
Floor
150+
L W concrete
30
N/A
Floor
150+
L W concrete
100
N/A
Wall
100+
L W concrete
30
Wall
100+
L W concrete
12
Floor
150+
L W Concrete
50mm
Floor
150+
L W Concrete
10mm
Floor
150+
L W Concrete
30mm
15mm CP601S 10mm CP601S 20mm CP601S 6mm CP601S N/A
Floor
150+
L W Concrete
10mm
N/A
Wall
150+
L W Concrete
50mm
Wall
150+
L W Concrete
10mm
20mm CP601S 6mm CP601S
Wall
150+
L W Concrete
30mm
N/A
Wall
150+
L W Concrete
10mm
N/A
Fire Resistance (min) Integrity (E) 240
Fire Resistance (min) Insulation (I) 240
240
240
240
240
120
120
120
120
240
240
240
240
240
120
240
240
240
240
240
240
240
90
240
240
Cert. No.
520a/01
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS
Note: 1. Product used as a linear gap seal Certificate No: 090a(5) to LPS 1132: Issue 4
CP 620 Expanding Firestop Foam - LPCB Ref No.: 090a(5) Product Name
Element of construction orientation
Element of construction thickness (mm)
Element of construction material
CP 620
Wall
100
Wall
100
Wall
100
Wall
100
Wall
100
Wall
100
Wall
100
Wall
100
Wall
100
Wall
100
Wall
100
Wall
100
Wall
120
concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall concrete, masonry or drywall drywall
Wall
120
Wall Wall
Depth of CP620 (mm) (notes 2 & 5) 145
Penetration Type (notes 1, 3, 4)
Penetration Size
Integrity
Insulation
Cert. No.
copper pipe
76mm dia
120
0
090a/03
200
copper pipe + insulation
120
120
145
steel pipe
76mm dia + insulation thickness 76mm dia
120
30
145
steel pipe + insulation
120
120
145
PVC pipe
114mm dia + insulation thickness 110mm dia
120
120
200
PE pipe
50mm dia
120
120
200
PE pipe
110mm dia
120
120
200
ABS pipe
110mm dia
120
120
200
single cable or cable bundle cable bundle
70mm dia
120
120
100mm dia
120
60
145 145
cable tray
150 x 25mm
120
120
200
cable tray
250 x 25mm
120
120
120
copper pipe + insulation
120
60
drywall
120
120
60
120 120
drywall drywall
120 120
cable trunking (Note 6) PVC pipe cable tray
77mm dia + insulation thickness 100 x 100mm
120 120
60 60
Floor Floor
150 150
LW Concrete LW Concrete
200 150
cable tray copper pipe + insulation
150 150
60 120
Floor Floor Floor
150 150 150
LW Concrete LW Concrete LW Concrete
200 200 200
PVC pipe PVC pipe steel pipe + insulation
150 150 150
90 90 90
Floor Floor Floor
150 150 150
LW Concrete LW Concrete LW Concrete
150 150 150
cable tray PVC pipe PVC pipe
100mm dia 150 x 25mm 150 x 25mm 150 x 25mm 320 x 60mm 89mm dia + insulation thickness 50mm dia 100mm dia 114mm dia + insulation thickness 320 x 60mm 50mm dia 100mm dia
120 120 120
30 60 60
20 Nov 2011
89
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation
Element of construction thickness (mm)
Element of construction material
Floor
150
LW Concrete
Depth of CP620 (mm) (notes 2 & 5) 150
Penetration Type (notes 1, 3, 4)
Penetration Size
Integrity
Insulation
steel pipe + insulation
114mm dia + insulation thickness
120
60
Cert. No.
Notes: 1. The penetrating services should be installed with a minimum separation of 100mm from any other penetrating service and a minimum distance of 50mm from the edge of the seal. 2. An additional bead of 25x25mm of CP620 should be applied around each service (except plastic pipes where it penetrates each face of the seal. 3. Plastic pipes (PE, PVC or ABS) must be fitted with Hilti CP643 pipe collars. 4. Please refer to manufacturer’s installation instructions for more details. 5. For seals thicker than the supporting wall, a framework should be installed using type 5 plasterboard. Refer to manufacturer’s instructions for further details. 6. Cable trunking tested with 30% fill of 12mm diameter cables and packed with CP651 cushions above cables at the location where the service passed through the partition. Certificate No: 090a(6) to LPS 1132: Issue 4
CF 125-50 Penetration Seals - LPCB Ref No.: 090a(6) Product Name
Element of construction orientation
CF 12550
Wall
Element of construction thickness (mm) 150
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Use
Integrity (minutes)
Insulation (minutes)
Cert. No.
Nominal 1mm coating of CP671
150mm CF 125-50
Nominal 1mm coating of CP671
300 x 300mm aperture in LW blockwork containing: 225 x 26mm steel cable types 525mm dia. 50mm galvanised steel pipe with 4.2mm wall thickness
30
30
090a/04
Certificate No: 090a(6) to LPS 1132: Issue 4
CF 125-50 Linear Gap Seals - LPCB Ref No.: 090a(6) Product Name
Element of construction orientation
CF 12550
90
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Use
Integrity (minutes)
Insulation (minutes)
Cert. No.
Wall
Element of construction thickness (mm) 100
900 x 15mm CF125-50
N/A
N/A
120
120
090a/04
Wall
100
900 x 15mm CF125-50
N/A
N/A
seal between softwood and LW blockwork seal between softwood and common brickwork
150
120
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Use
Integrity (minutes)
Insulation (minutes)
Wall
Element of construction thickness (mm) 150
Nominal 1mm coating of CP671
900 x 50mm CF125-50
Nominal 1mm coating of CP671
150
120
Wall
200
950x 135 x 20 mm CF125-50
N/A
15mm CP606 mastic
240
120
Wall
100
950 x 15mm
N/A
N/A
120
120
Wall
100
Up to 25mm dia. Holes
N/A
N/a
120
120
Floor
150
950 x 135 x 20 mm CF12550
N/A
15mm CP606 mastic
seal between mortar lintel and steel deck seal between concrete faces seal between concrete faces seal between concrete faces seal between concrete faces
240
180
Cert. No.
Certificate No: 090a(8) to LPS1132: Issue 4
CP 606 Intumescent Mastic - Penetration Seals - LPCB Ref No.: 090a(8) Product Name CP 606
Element of construction orientation 100mm AC wall
Configuration: gap size (mm) N/A
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Use
Integrity (min)
Insulation (min)
Cert. No.
20mm CP606
60mm Rockfibre 100kg/m3 density
20mm CP606
240
0
090a/07
150mm AC floor
N/A
80mm Rockfibre/m3 100kg/m3 density
N/A
20mm CP606
240
0
100mm AC wall with cylindrical steel sleeve
Max 30mm
70mm Rockfibre 140kg/m3 density
N/A
15mm CP606
42mm copper pipe with 1.25mm wall thickness 42mm copper pipe with 1.25mm wall thickness Up to 600mm steel pipe with minimum 3mm wall thickness
240
0
Certificate No: 090a(8) to LPS1132: Issue 4
CP 606 Intumescent Mastic - Linear Gap Seals - LPCB Ref No.: 090a(8) Product Name CP 606
Element of construction orientation 150mm AC/AC floor
20 Nov 2011
Gap Size (mm)
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Up to 15
30mm PE foam rod
N/A
60mm CP606
Use
Integrity (min)
Insulation (min)
Cert. No.
120
60
090a/07
91
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation 150mm AC/AC floor
Gap Size (mm)
Configuration: fire side
Configuration: middle
Configuration: non-fire side
15 to 30
30mm PE foam rod
N/A
150mm AC/AC floor 150mm AC/AC floor
Up to 15 15 to 30
135mm of CF125-50 135mm of CF125-50
N/A
Vertical linear gap between 150mm AC blockwork wall minimum density 760kg/m³ /Galvanised Mild steel angle 150mm x 20mm x 2mm thick Vertical linear gap between 150mm AC blockwork wall minimum density 760kg/m³ / Galvanised mild steel angle 150mm x 20mm x 2mm thick Horizontal linear gap between 150mm AC blockwork wall minimum density 760kg/m³ / Galvanised mild steel angle 150mm x 20mm x 2mm thick 150mm AC/AC floor
30mm
10mm CP606 & 25mm Ø PE backing rod
N/A
30mm
10mm CP606
50mm
Up to 15
150mm AC/AC floor
92
20 to 30
Integrity (min)
Insulation (min)
10mm of CP606 for gaps of 15mm. 15mm of CP606 for gaps of 20 to 30mm. 6mm CP606
240
120
120
60
10mm of CP606 for gaps of 15mm. 15mm of CP606 for gaps of 20 to 30mm. 10mm CP606 & 25mm Ø PE backing rod
240
120
240
90
130mm Mineral wool 96kg/m²
10mm CP606
240
90
10mm CP606 & 2 x 25mm Ø PE backing rod
N/A
N/A
30
0
70mm of Rockfibre 140kg/m3 density 70mm of Rockfibre 140kg/m3 density
N/A
10mm CP606
240
240
N/A
15mm CP606
240
210
N/A
Use
Cert. No.
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation 75mm steel/steel or AC/steel floor
Gap Size (mm)
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Up to 15
N/A
75mm steel/steel or AC/steel floor
20 to 30
150mm AC/AC floor
6 to 15
100mm plasterboard partition wall head to corrugated metal decking 100mm plasterboard partition wall head to corrugated metal decking 100mm plasterboard partition wall head to AC block
Dependant on decking profile
70mm of Rockfibre 140kg/m3 density 70mm of Rockfibre 140kg/m3 density 144mm of Rockfibre 100kg/m3 density 10mm CP606
100mm plasterboard partition wall head to AC block 65mm AC wall with cement board facings and galvanised steel top channel Steel framed doorset in steel or AC supporting wall Timber framed doorset in timber or concrete supporting wall Timber framed doorset in timber or concrete supporting wall
20 Nov 2011
Use
Integrity (min)
Insulation (min)
10mm CP606
240
0
N/A
15mm CP606
240
30
N/A
6mm CP606
240
240
80mm of Rockfibre 100kg/m3 density
10mm CP606
120
120
Dependant on decking profile
5mm CP606
90mm of Rockfibre 100kg/m3 density
5mm CP606
120
120
10
10mm CP606 & 15mm of Rockfibre 100kg/m3 density
N/A
120
120
5
5mm CP606 & 20mm of Rockfibre 100kg/m3 density 6mm CP606
N/A
10mm CP606 & 15mm of Rockfibre 100kg/m3 density 5mm CP606 & 20mm of Rockfibre 100kg/m3 density N/A
120
120
120
120
6 to 15
30
Up to 6
Minimum 70mm Rockfibre 140kg/m3 density 6mm CP606
6 to 30
15mm CP606
N/A
N/A
15mm CP606
240
0
Minimum 78mm Rockfibre 140kg/m3 density
6mm CP606
120
0
Minimum 65mm Rockfibre 140kg/m3 density
15mm CP606
120
0
Cert. No.
93
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation Hardwood timber framed doorset with or without Architraves in concrete or masonry wall construction 670kg/m³ minimum density (1) Hardwood timber framed doorset with or without Architraves in concrete or masonry wall construction 670kg/m³ minimum density (1) Hardwood timber framed doorset with or without Architraves in concrete or masonry wall construction 670kg/m³ minimum density (1) Hardwood timber framed doorset with or without Architraves in concrete or masonry wall construction 670kg/m³ minimum density (1)
Gap Size (mm)
Configuration: fire side
Configuration: middle
Configuration: non-fire side
Up to 10mm
5mm CP606 & (optional) Ø PE backing rod
N/A
10 to 18mm
5mm CP606 & Ø PE backing rod
18 to 30mm
Up to 30mm
Use
Integrity (min)
Insulation (min)
5mm CP606 & (optional) Ø PE backing rod
120
0
N/A
5mm CP606 & Ø PE backing rod
90
0
10mm CP606 & Ø PE backing rod
N/A
10mm CP606 & Ø PE backing rod
90
0
10mm CP606
Minimum 180mm tightly packed stone mineral fibre
10mm CP606
120
0
Cert. No.
Notes: 1. For FD30 Doorsets the following frame materials are applicable Softwood, Hardwood & Mineral composite having minimum density’s of 450kg/m² or MDF having a minimum density of 750kg/m³. For FD60 & FD90 Doorsets the following frame materials are applicable Hardwood & Mineral composite having a density of 620kg/m³. 2. AC - Aerated Concrete. 3. Please refer to Hilti installation instructions for further detail Certificate No: 090a(9) to LPS1132: Issue 4
94
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS CP 657 Blocks With CP611A Sealant - LBCB Ref. No. 090a(9) Product Name
Element of construction orientation
Element of construction thickness (mm)
Element of construction material
Use
CP 657 blocks with CP611A sealant
Wall
200
Concrete or masonry
60.3 mm diameter x 2.9 mm wall thickness steel pipe penetration
Wall
200
Wall
200
Concrete or masonry Concrete or masonry
Wall
200
Concrete or masonry
Wall
200
Concrete or masonry
Wall
200
Concrete or masonry
Wall
200
Concrete or masonry
Wall
200
Concrete or masonry
Wall
200
Wall
200
Concrete or masonry Concrete or masonry
Floor
200
Concrete
Floor
200
Concrete
Floor
200
Concrete
Floor
200
Concrete
Floor
200
Concrete
22 mm diameter copper pipe 28.9 mm diameter x 2.6mm wall thickness stainless steel pipe 168.3 mm diameter x 4.5 mm wall thickness steel pipe with Autopack 25 mm thick Rockwool and PVC applied insulation 50 mm diameter x 3 mm wall thickness PVC pipe 50 mm diameter x 5 mm wall thickness polyethylene pipe 316 mm wide cable tray supporting 15 off 3x4 mm 2 PVC/copper cables 110 mm wide cable tray supporting 3 off 3x50 mm 2 PVC/copper cables Cable bundle 40 cables 2x1.5mm 2 316 mm wide cable tray supporting 3 off bundles of 10 cables 20x2x0.6mm 2 50 mm diameter x 3 mm wall thickness PVC pipe 60.3 mm diameter x 2.9 mm wall thickness steel pipe penetration 50 mm diameter x 5 mm wall thickness polyethylene pipe 110 mm wide cable tray supporting 3 off 3x50 mm 2 PVC/copper cables 316 mm wide cable tray supporting 30 off PVC/copper cables, 15 3x4 mm 2 , 15 4x2.5 mm 2
Fire Resistance Integrity (min) (E) 180
Fire Resistance Insulation (min) (I) 120
180
120
180
180
180
90
180
180
180
180
180
180
180
90
180
180
180
120
180
180
180
120
180
180
180
120
180
180
Cert. No.
090a/08
Note: For CP657 Blocks with CP611A sealant: The CP 657 blocks shall be compress fitted into the aperture with blocks cut, where required, to fit around the services and aperture. CP 611A sealant shall be applied on blocks in direct contact with the aperture and for the full depth of the aperture (200mm) around each penetration element of a thickness nominally 5mm (15mm around pipes). Cable bundles shall be completely filled with CP 611A sealant. See manufacturer's installation/application instruction for full details. Certificate No: 090a(7) to LPS1132: Issue 4
20 Nov 2011
95
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS CP 672/CFS-SP WB Linear Gap Seals - LPCB Ref No: 090a(7) Product Name
Element of construction Orientation
Element of construction Thickness/ Depth (mm)
Element of construction Material
Application
CP 672/CFSSP WB Fire stop joint spray with Rockwool RP-V
Vertical joint in Wall
150 (minimum)
Aerated Concrete, blockwork or masonry. Minimum density 380kg/m³
CP 672/CFSSP WB Fire stop joint spray with Rockwool Termarock 40
Vertical joint in Wall
150 (minimum)
Aerated Concrete, or masonry. Minimum density 380kg/m³
CP 672/CFSSP WB Fire stop joint spray with Rockwool RP-V
Floor
150 (minimum)
Concrete and blockwork. Minimum density 2400kg/m³
CP 672/CFSSP WB Fire stop joint spray with Rockwool Termarock 40
Floor
150 (minimum)
Concrete and blockwork. Minimum density 2400kgm³
Maximum joint width 100 mm, minimum installation depth 150mm. Joint 50% compression filled with 50mm thick layers of Rockwool RPV mineral fibre panels of nominal 38.5kg/m3 density compress fitted trimmed flush with both the inner and outer surface of the joint. Both surfaces spray coated with CP 672/CFS-SP WB nominally 3-5mm thick extending beyond the edge of the joint onto surface of surrounding construction by a minimum of 15mm each side. 25% lateral expansion applied during test. Maximum joint width 100 mm, minimum installation depth 150mm. Joint 50% compression filled with 50mm thick layers of Rockwool Termarock 40 mineral fibre panels of nominal 42.6kg/m 3 density compress fitted trimmed flush with both the inner and outer surface of the joint. Both surfaces spray coated with CP 672/CFS-SP WB nominally 3-5mm thick extending beyond the edge of the joint onto surface of surrounding construction by a minimum of 15mm each side. 0-40% lateral expansion applied during tests. Maximum joint width 100 mm, minimum installation depth 100mm. Joint 50% compression filled with 50mm thick layers of Rockwool RPV mineral fibre panels of nominal 38.5kg/m 3 density compress fitted trimmed flush with the upper (nonfire) surface of the joint. The upper surface spray coated with CP 672/CFS-SP WB nominally 3-5mm thick extending beyond the edge of the joint onto surface of surrounding construction by a minimum of 15mm each side. 025% lateral expansion applied during test. Maximum joint width 100 mm, minimum installation depth 100mm. Joint 50% compression filled with 50mm thick layers of Rockwool Termarock 40 mineral fibre panels of nominal 42.6kg/m 3 density compress fitted trimmed flush with the upper (non-fire) surface of the joint. The upper surface spray coated with CP 672/CFS-SP WB nominally 3-5mm thick extending beyond the edge of the joint onto surface of surrounding construction by a minimum of 15mm each side. 40% lateral expansion applied during test.
96
Fire Resistance (min) Integrity/ Insulation (EN 13664) 240/240
Cert. No.
090a/05
240/240
240/120
240/120
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS
Certificate No: 090a(7) to LPS1132: Issue 4
CP 672/CFS-SP WB Linear Gap Seals - LPCB Ref No: 090a(7) Product Name
Element of construction Orientation
Element of construction Thickness /Depth (mm)
Element of construction Material
Application
CP 672/CFSSP WB Fire stop joint spray with 64kg/m³ density mineral fibre batt
Floor
115
Lightweight concrete floor slab
CP 672/CFSSP WB Fire stop joint spray with 32kg/m³ density mineral fibre batt
Floor
115
Lightweight concrete floor slab
CP 672/CFSSP WB Fire stop joint spray with CP 777 plugs and CP 757 strips
Wall head to concrete topped metal deck assembly
Wall thickness 100 Floor assembly 140
Note 1
Maximum joint width 75mm, minimum installation depth 115mm. Joint filled with 4 layers of 108mm wide x 38mm thick layers of mineral fibre batt of nominal 64kg/m 3 density 50% compress fitted flush with the lower (fire side) surface of the joint. The upper surface spray coated with CP 672/CFS-SP WB nominally 6mm thick flush with the upper (non-fire) surface and extending beyond the edge of the joint onto surface of surrounding construction by a minimum of 20mm each side Maximum joint width 90mm, minimum installation depth 115mm. Joint filled with 4 layers of 112mm wide x 38mm thick layers of mineral fibre batt of nominal 32kg/m 3 density 42% compress fitted flush with the lower (fire side) surface of the joint. The upper surface spray coated with CP 672/CFS-SP WB nominally 3mm thick flush with the upper (non-fire) surface and extending beyond the edge of the joint onto surface of surrounding construction by a minimum of 12mm each side Minimum 25mm gap between wall head and metal deck increasing to 100 mm into deck profile. CP 777 plugs friction fitted to completely fill deck profile cavities flush with both sides of wall. CP 767 strips compressed 50% and inserted into remaining joint gaps flush with both sides of wall. Complete outer surface of joint coated with CP 672/CFS-SP WB nominally 3 mm thick extending beyond the perimeter of the seal onto surface of surrounding gypsum wall and decking by 13mm on both sides of wall assembly.
20 Nov 2011
Fire Resistance (mm) Integrity/ Insulation (BS 476: Part 20) 240/120
Cert. No.
090a/05
180/120
120/120
97
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction Orientation
Element of construction Thickness /Depth (mm)
Element of construction Material
Application
CP 672/CFSSP WB Fire stop joint spray with 64 kg/m³ mineral wool
Wall head to concrete topped metal deck assembly
Wall thickness 200 Floor assembly 140
Note 2
CP 672/CFSSP WB Fire stop joint spray with 40kg/m³ Mineral wool
Floor / Curtain wall system
Floor thickness 200
Floor Reinforced Concrete. Mminimum density 2200kg/m³
CP 672/CFSSP WB Fire stop joint spray with 64 kg/m³ mineral wool
Partition wall head to floor soffit
Note 3
Note 3
CP 672/CFSSP WB Fire stop joint spray with 64kg/m³ mineral wool
Concrete/Masonry wall head to floor soffit
Note 4
Note 4
CP 672/CFSSP WB Fire stop joint spray with 32 kg/m³ mineral wool
Partition wall head to composite floor
Note 5
Note 5
Minimum 90 mm gap between wall head and metal deck increasing to 165 mm into deck profile. Mineral wool of 64 kg/m 3 density 50% compress packed into flutes/joint flush with both sides of wall. Complete outer surface of joint coated with CP 672/CFS-SP WB nominally 3 mm thick extending beyond the perimeter of the seal onto surface of surrounding gypsum wall and decking by 13mm on both sides of wall assembly. Maximum gap between supporting floor and the façade (Curtain wall system) 210mm. The Horizontal Linear gap seal (perimeter seal) system comprised of 7 layers of mineral wool board (RPV -40 Rockwool) 200mm wide 60mm thick compressed to 50% and with a density of 40kg/m³. Mineral wool coated on the upper surface (non-fire side) with dry film thickness of 1.52.0mm of CP 672/CFS-SP WB fire stop joint spray. Minimum 25mm gap between wall head and floor soffit. Joint seal comprising of Mineral wool 64 kg/m³ with 50% compression filled to the full depth of the wall and coated with CP 672/CFS-SP WB Fire stop joint spray Minimum 25mm gap between wall head and floor soffit. Joint seal comprising of Mineral wool 64 kg/m³ with 50% compression filled to the full depth of the wall and coated with CP 672/CFS-SP WB Fire stop joint spray. Maximum 50mm gap between the top of the wall partition boards and the valleys of the steel floor construction. Joint seal comprising of Mineral wool 32 kg/m³ with 50% compression fitted between the wall board edges and the underside of the steel floor construction either side of the wall coated with a 3mm wet thickness coating of CP 672/CFS-SP WB Fire stop joint spray overlapping the spray applied steel protection material by 50mm and by 12mm over the wall boards.
98
Fire Resistance (mm) Integrity/ Insulation (BS 476: Part 20) 120/120
Cert. No.
120/120
240/240
240/240
120/120
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction Orientation
Element of construction Thickness /Depth (mm)
Element of construction Material
Application
CP 672Y/CFSSP WB Fire stop joint spray with 32 kg/m³ mineral wool
Partition wall head to composite floor
Note 6
Note 6
CP 672/CFSSP WB Fire stop joint spray with 32kg/m³ mineral wool
Partition wall head to composite floor
Note 7
Note 7
Maximum 100mm aperture around the lattice beam. Joint seal comprising of Mineral wool 32 kg/m³ with 50% compression fitted into the aperture around the lattice beam and coated with a 3mm wet thickness coating of CP 672/CFS-SP WB Fire stop joint spray to all exposed mineral wool overlapping the spray applied steel protection material by 50mm and by 12mm over the wall boards. Maximum 25mm gap between the top of the wall partition boards and the valleys of the steel floor construction. Joint seal comprising of layers of Mineral wool 32 kg/m³ cut to the shape of the fluted floor units approximately 20% larger than the widths of the flutes and compression fitted into the flutes of the floor units above the ceiling channel, additional 50mm x 30mm sections of mineral wool shall be 50% compression fitted between the top of the wall boards and the underside of the steel floor units either side of the wall and coated with a 3mm wet thickness coating of CP 672Y/CFS-SP WB Fire stop joint spray to exposed mineral wool and overlapping the wall boards by 12mm.
Fire Resistance (mm) Integrity/ Insulation (BS 476: Part 20) 120/120
Cert. No.
120/120
Notes: 1 2 hour fire rated Wall 64 mm steel stud faced on each side with 2 x 15 mm layers Type ‘X’ gypsum board and Profiled metal deck assembly topped with 64 mm concrete. 2. Concrete block wall and Profiled metal deck assembly topped with 64 mm concrete. 3. Applicable to UL Joint system No’s. HW-D-0292 & HW-D-0295. The specification of the gypsum board based drywall and composite steel/concrete profiled deck supporting constructions shall provide the required fire resistance of 240 minutes. 4. Applicable to UL Joint system No’s HW-D-0294 & HW-D-0296. The specification of the concrete/masonry wall and composite steel/concrete profiled deck supporting constructions shall provide the required fire resistance of 240 minutes. 5. Applicable to UL Joint system No’s. HW-D-0190. The specification of the gypsum board based drywall and composite steel/concrete profiled deck supporting constructions shall provide the required fire resistance of 120 minutes. 6. Applicable to UL Joint system No’s. HW-D-0218. The specification of the gypsum board based drywall and composite steel/concrete profiled deck supporting constructions shall provide the required fire resistance of 120 minutes. 7. Applicable to UL Joint system No’s. HW-D-0042 & HW-D-0049. The specification of the gypsum board based drywall and composite steel/concrete profiled deck supporting constructions shall provide the required fire resistance of 120 minutes.
Certificate No: 090a(10) to LPS1132: Isuue 4
20 Nov 2011
99
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS CP 660 Wall System - LPCB Ref No.: 090a(10) Product Name
Element of construction orientation
CP 660
Wall (system H)
100
Element of construction thickness (mm) 120
Element of construction material
Wall (system A)
120
Drywall
Wall (system B)
120
Drywall
Drywall
Penetration Type Penetration Type Blank seal without service penetrations Perforated 300mm wide 1.5mm thick mild steel cable tray (1) with 1x50mm dia. Copper core electric Cable, 1x32mm dia. Copper core Electric Cable, 3x16mm dia. Mild steel pipes with 1.5mm wall thickness and 3x16mm dia. Plastic pipes with 1.0mm wall thickness and Perforated 300mm wide 1.5mm thick mild steel cable tray (1) with 2x50mm dia. Aluminium core Electric Cables and 1x70mm dia. Copper core Electric cable. Perforated 300mm wide 1.5mm thick mild steel cable tray (1) with 15x13mm dia. Copper core Electric Cables in 2 layers and 30x12mm communication cables in bundle. and Perforated 300mm wide 1.5mm thick mild steel cable tray (1) with 15x12mm dia. Copper core Electric Cables in 2 layers
Penetration/seal Size (mm)
Integrity (min)
Insulation (min)
Cert. No.
400 x 400 x 120 thick
120
120
090a/09
400 x 400 x 120 thick
120
60
400 x 400 x 120 thick
120
90
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation Wall (system C)
Wall (system D)
20 Nov 2011
Element of construction thickness (mm) 120
Element of construction material
120
Drywall
Drywall
Penetration Type Penetration Type 1x50mm dia. PVC-u pipe with 2.4mm wall thickness (2) and 1x50mm dia. PVC-u pipe with 1.8mm wall thickness (2) and CP64350/1.5N pipe collar on each side of penetration seal (4) and 1x110mm dia. PVC-u pipe with 1.8mm wall thickness (3) and CP643-110/4N pipe collars on each side of the penetration seal (4) and 1x110mm dia. PVC-u pipe with 12.3mm wall thickness (3) and CP643-110/4N pipe collars on each side of the penetration seal (4) 1x50mm dia. PVC-u pipe with 1.8mm wall thickness (2) with 1 layer of CP648-E pipe wrap (5). and 1x110mm dia. PVC-u pipe with 1.8mm wall thickness (3) with 2 layers of CP648-E pipe wrap (5). and 1x110mm dia. PVC-u pipe with 12.3mm wall thickness (3) with 2 layers of CP648-E pipe wrap (5).
Penetration/seal Size (mm)
Integrity (min)
Insulation (min)
400 x 400 x 120 thick
120
120
400 x 400 x 120 thick
120
120
Cert. No.
101
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation Wall (system F)
Element of construction thickness (mm) 120
Element of construction material Drywall
Penetration Type Penetration Type 1x110mm dia. PE pipe with 12.5mm wall thickness (3) and CP643110/4N pipe collars on each side of the penetration seal (4) and 1x110mm dia. PE pipe with 2.4mm wall thickness (3) and CP643110/4N pipe collars on each side of the penetration seal (4) and 1x50mm dia. PE pipe (2) with 4.2mm wall thickness and 1x50mm dia. PE pipe (2) with 2.4mm wall thickness and CP64350/1.5N pipe collars on each side of the penetration seal (4)
Penetration/seal Size (mm)
Integrity (min)
Insulation (min)
400 x 400 x 120 thick
120
120
Cert. No.
Notes: Wall system 1. Cable tray fixed to Hilti MQ41/3 unistrut support system, wire cable ties used with cable tray on both sides of the penetration. 2. Pipe fixed to Hilti MQ41/3 unistrut support system using Hilti MPN-S 1.5” pipe clamps. 3. Pipe fixed to Hilti MQ41/3 unistrut support system using Hilti MPN-S 110mm pipe clamps. 5. Pipewrap fixed with ‘Pattex’ self-adhesive tape. Certificate No: 090a(10) to LPS1132: Issue 4
CP 660 Floor System - LPCB Ref No.: 090a(10) Product Name
Element of construction orientation
CP 660
Floor (system A)
102
Element of construction thickness (mm) 150 concrete (6)
Element of construction material Aerated concrete (6)
Penetration Type Penetration Type Blank seal without service penetrations
Penetration/seal Size
Integrity (min)
Insulation (min)
Cert. No.
400 x 400 x 150 thick
120
90
090a/09
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation Floor (system B)
20 Nov 2011
Element of construction thickness (mm) 150
Element of construction material Aerated concrete (6)
Penetration Type Penetration Type Perforated 300mm wide 1.5mm thick mild steel cable tray (1) with 1x50mm dia. Copper core Electric Cable, 1x32mm dia. Copper core Electric Cable, 3x16mm dia. Mild steel pipes with 1.5mm wall thickness and 3x16mm dia. Plastic pipes with 1.0mm wall thickness. and Perforated 300mm wide 1.5mm thick mild steel cable tray (1) with 2x50mm dia. Aluminium core Electric Cables and 1x70mm dia. Copper core Electric cable.
Penetration/seal Size
Integrity (min)
Insulation (min)
400 x 400 x 150 thick
180
90
Cert. No.
103
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation Floor (system C)
104
Element of construction thickness (mm) 150
Element of construction material Aerated concrete (6)
Penetration Type Penetration Type 1x50mm dia. PVC-u pipe with 4.8mm wall thickness (2) and 1x50mm dia. PVC-u pipe with 1.8mm wall thickness (2) and CP64350/1.5N pipe collar on exposed side of penetration seal (4) and 1x110mm dia. PVC-u pipe with 1.8mm wall thickness (3) and CP643110/4N pipe collars on exposed side of the penetration seal (4) and 1x110mm dia. PVC-u pipe with 12.3mm wall thickness (3) and CP643110/4N pipe collars on exposed side of the penetration seal (4)
Penetration/seal Size
Integrity (min)
Insulation (min)
400 x 400 x 150 thick
180
180
Cert. No.
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation Floor (system E)
Floor (system H)
20 Nov 2011
Element of construction thickness (mm) 150
Element of construction material
150
Aerated concrete (6)
Aerated concrete (6)
Penetration Type Penetration Type 1x110mm dia. PE pipe with 12.5mm wall thickness (3) and CP643110/4N pipe collars on exposed side of the penetration seal (4) and 1x110mm dia. PE pipe with 2.4mm wall thickness (3) and CP643110/4N pipe collars on exposed side of the penetration seal (4) and 1x50mm dia. PE pipe with 4.2mm wall thickness (2) and 1x50mm dia. PE pipe with 2.4mm wall thickness (2) and CP64350/1.5N pipe collars on exposed side of the penetration seal (4) 1x50mm dia. PVC-u pipe with 1.8mm wall thickness (2) with 1 layer of CP648-E pipe wrap (5).and 1x110mm dia. PVC-u pipe with 1.8mm wall thickness (3) with 2 layers of CP648-E pipe wrap (5). and 1x110mm dia. PVC-u pipe with 12.3mm wall thickness (3) with 2 layers of CP648-E pipe wrap (5).
Penetration/seal Size
Integrity (min)
Insulation (min)
400 x 400 x 150 thick
180
180
400 x 400 x 150 thick
180
180
Cert. No.
105
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of construction orientation Floor (system I)
Element of construction thickness (mm) 150
Element of construction material Aerated concrete (6)
Penetration Type Penetration Type 1x50mm PE pipe with 2.4mm wall thickness (2) with 1 layer of CP648-E pipe wrap (5). and 1x110mm PE pipe with 2.4mm wall thickness (3) with 2 layers of CP648-E pipe wrap (5). and 1x110mm PE pipe with 12.5mm wall thickness (3) with 2 layers of CP648-E pipe wrap.(5)
Penetration/seal Size
Integrity (min)
Insulation (min)
400 x 400 x 150 thick
180
180
Cert. No.
Notes: Floor system 1. Cable tray fixed to Hilti MQ41/3 unistrut support system, wire cable ties used with cable tray on both sides of the penetration. 2. Pipe fixed to Hilti MQ41/3 unistrut support system using Hilti MPN-S 1.5” pipe clamps. 3. Pipe fixed to Hilti MQ41/3 unistrut support system using Hilti MPN-S 110mm pipe clamps. 4. Fixed to the unexposed face of the penetration seal using M8 threaded rods with hexagonal head steel nuts and washers. 5. Pipewrap fixed with ‘Pattex’ self-adhesive tape. 6. Aerated concrete density 670g/m3
Certificate No: 090a (11) to LPS 1132: Issue 4
Penetration Gap Seals – CP670 Fire Safety System (Unframed single layer 50mm) Product Name
Elements of Construction Orientation
CP 670 Fire Safety System
106
Element of Construction Material
Aperture Size
Penetration Type (3)
Wall
Elements of Construction Thickness min (mm) 100
Fire Resistance Integrity (min) 90
Fire Resistance Insulation (min) 30
LW Concrete/ Masonry/ Plasterboard partition
Cables 10mm (5)(6)
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1).
Cables 10mm <Ø ≤20mm(5)(6)
90
60
Cables 20mm <Ø ≤40mm(5)(6)
90
30
Cables 40mm < Ø≤75mm(5)(6)
90
60
Cert. No. 090a/10
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Elements of Construction Orientation
Fire Resistance Integrity (min) 120
Fire Resistance Insulation (min) 60
Mild Steel Trunking 250mm x 250mm x 1.5mm thick
120
30
Blank Seals
120
60
Steel Pipes 114mm & 250mm Ø x 6.3mm thick
120
0
Copper Pipes 108mm Ø x 2mm thick
120
0
CP642 Collars (recessed/surface mounted) pipes ≤ 160 mm Ø x 5.6mm thick
120
60
CP643 Collars (recessed) PVC pipes ≤ 110 mm Ø x 4mm thick
120
0
Element of Construction Material
Aperture Size
Penetration Type (3)
Wall
Elements of Construction Thickness min (mm) 100
LW Concrete/ Masonry/ Plasterboard partition
Cable Trays
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high (1).
Cert. No.
Notes: 1. LPCB Ref No 090a/10 CP670 Fire Safety System consists of pre-coated CP670 Fire Safety Board (Rocksilk Universal Slab RS 160 180 mineral wool batt maximum 1200m x 600mm wide having a 160-180kg/m3 density utilising cruciform joints at maximum dimensions of 2400mm x 1200mm wide), coated with CP 670 Fire Safety Coating nominally 0.7mm thick extending beyond the perimeter of the seal onto surface of surrounding construction by 12.5mm unless otherwise stated. 2. All Gaps around all penetration types are to be sealed with Hilti CP606 (or CP611A where indicated (a)) mastic joint filler. 3. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in any manner for the stated period 4. CP642 Collars are approved with Polyethylene (PE), Polyvinyl chloride (PVC), Polypropylene (PP), Polybutylene (PB), and Acrylonitrile butadiene styrene (ABS) pipes only. 5. All cables required to provide 90 to 120 minutes insulation and integrity must include a 150mm coat back of CP670 Fire safety coating, where 60 minutes integrity and insulation is required the coat back may be reduced to 100mm and no coat back is required where 30 minutes integrity and insulation is required. 6. Cables may be individual or bunched where they penetrate the CP 670 Fire safety system. Certificate No: 090a(11) to LPS 1132: Issue 4
20 Nov 2011
107
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Penetration Gap Seals -CP670 Fire Safety System (Framed double layer 100mm) (4) (8) Product Name
Element of Construction Orientation
CP 670 Fire Safety System (1)
108
Element of Construction Material
Aperture Size
Penetration Type
Wall
Element of Construction Thickness min (mm) 130
LW Concrete/ Masonry/ Plasterboard partition
Cables ≤ 20mm Ø
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high
Fire Resistance (min) Integrity 180
Fire Resistance (min) Insulation 200
Cables 20mm < Ø ≤ 40mm
180
120
Cables 40mm < Ø ≤ 75mm
180
120
Cable Trays
180
120
Mild Steel Trunking 250mm x 250mm x 1.5mm thick
120
30
Blank Seals
240
180
Steel Pipes ≤ 250mm Ø x 6.3mm thick
240
30
Copper Pipes ≤ 108mm Ø x 2mm thick
240
0
CP642 Collars (recessed) pipes ≤ 160 mm Ø x 5.6mm thick
240
60
Cert. No. 090a/10
(5)
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of Construction Orientation
Element of Construction Material
Aperture Size
Penetration Type
Wall
Element of Construction Thickness min (mm) 130
LW Concrete/ Masonry/ Plasterboard partition
CP642 Collars (surface mounted)
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Wall
130
LW Concrete/ Masonry/ Plasterboard partition
Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high Maximum aperture size 3000 mm wide x 5000 mm high
Fire Resistance (min) Integrity 240
Fire Resistance (min) Insulation 60
CP642 Collars (independently supported ≤ 250mm Ø) (7)
90
60
CP643 Collars (recessed) PVC pipes ≤ 110 mm Ø x 4mm thick
120
0
Cert. No.
Notes: 1. LPCB Ref No 090a/10 CP670 Fire Safety System consists of pre-coated CP670 Fire Safety Board (Rocksilk Universal Slab RS 160 180 mineral wool batt maximum 1200m x 600mm wide having a 160-180kg/m3 density utilising cruciform joints at maximum dimensions of 2400mm x 1200mm wide), coated with CP 670 Fire Safety Coating nominally 0.7mm thick extending beyond the perimeter of the seal onto surface of surrounding construction by 12.5mm unless otherwise stated. 2. All Gaps around all penetration types are to be sealed with Hilti CP606 mastic joint filler. 3. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in any manner for the stated period. 4. CP670 Fire Safety System (Framed Double Layer system) comprises of an internal steel channel section framework clad on both faces with 50mm thick coated CP670 Fire Safety Boards which are retained to the framework via insulation pins and non return washers. 5. CP642 Collars are approved with Polyethylene (PE), Polyvinyl chloride (PVC), Polypropylene (PP), Polybutylene (PB), and Acrylonitrile butadiene styrene (ABS) pipes only. 6. 150mm coat back of CP670 Fire Safety Coating required. 7. CP642 Collars Independently supported is available with Polyethylene (PE) and Polyvinyl chloride (PVC) only. 8. The framed assembly shall be provided with 25mm of expansion allowance with an additional 20mm restricted expansion which the system is proved to be capable of accommodating without any undue effects. Certificate No: 090a(11) to LPS 1132: Issue 4
Penetration Gap Seals – CP670 Fire Safety System (Unframed double layer 100mm) Product Name
Element of Construction Orientation
Element of Construction Thickness min (mm)
Element of Construction Material
Aperture Size
Penetration Type
CP 670 Fire Safety System (1)
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Cables 10mm
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Maximum aperture size 5000 mm wide x 2400 mm high (1). Maximum aperture size 5000 mm wide x 2400 mm high
20 Nov 2011
Cables 10mm <Ø≤20mm(5)
Fire Resistance (min) Integrity (E) 120
Fire Resistance (min) Insulation (I) 120
120
120
Cert. No.
090a/10
(6)
109
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
110
Element of Construction Orientation
Element of Construction Thickness min (mm)
Element of Construction Material
Aperture Size
Penetration Type
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Cables 20mm < Ø≤40mm(5)(6)
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Maximum aperture size 5000 mm wide x 2400 mm high Maximum aperture size 5000 mm wide x 2400 mm high Maximum aperture size 5000 mm wide x 2400 mm high Maximum aperture size 5000 mm wide x 2400 mm high Maximum aperture size 5000 mm wide x 2400 mm high Maximum aperture size 5000 mm wide x 2400 mm high Maximum aperture size 5000 mm wide x 2400 mm high Maximum aperture size 5000 mm wide x 2400 mm high Maximum aperture size 5000 mm wide x 2400 mm high
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Fire Resistance (min) Integrity (E) 120
Fire Resistance (min) Insulation (I) 120
Cables 40mm <Ø≤75mm
120
120
Cable Trays
120
60
Mild Steel Trunking 250mm x 250mm x 1.5mm thick
120
30
Blank Seals
120
120
Steel Pipes 114mm Ø x 4mm thick (110kg/m³ mineral fibre jacket 450 x 40mm thick) Steel Pipes ≤ 250mm Ø x 6.3mm thick (unprotected)
120
120
120
0
Copper Pipes ≤ 108mm Ø x 2mm thick
120
0
CP642 Collars (recessed) pipes ≤ 160 mm Ø x 5.6mm thick (4)
120
60
Cert. No.
(5)(6)
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of Construction Orientation
Element of Construction Thickness min (mm)
Element of Construction Material
Aperture Size
Penetration Type
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Maximum aperture size 5000 mm wide x 2400 mm high
Wall
100
LW Concrete/ Masonry/ Plasterboard partition
Maximum aperture size 5000 mm wide x 2400 mm high
CP642 Collars (surface mounted) pipes ≤ 160 mm Ø x 5.6mm thick (4) CP643 Collars (recessed) PVC pipes ≤ 110 mm Ø x 4mm thick
Fire Resistance (min) Integrity (E) 120
Fire Resistance (min) Insulation (I) 60
120
0
Cert. No.
Notes: 1. CP670 Fire Safety System (Unframed Double Layer system) utilises cruciform joints within the CP670 Fire Safety System at Maximum dimensions of 2400mm high x 1200mm wide. No single batt is to be of greater dimensions than 1200mm high x 600mm coated with CP 670 Fire Safety Coating nominally 0.7mm thick extending beyond the perimeter of the seal onto surface of surrounding construction by 12.5mm unless otherwise stated and should have an additional CP670 Fire Safety Coating to batt edges. 2. All Gaps around all penetration types are to be sealed with Hilti CP606 mastic joint filler. 3. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in any manner for the stated period. 4. CP642 Collars are approved with Polyethylene (PE), Polyvinyl chloride (PVC), Polypropylene (PP), Polybutylene (PB), and Acrylonitrile butadiene styrene (ABS) pipes only 5. All cables required to provide 90 to 120 minutes insulation and integrity must include a 150mm coat back of CP670 Fire Safety Coating, where 60 minutes integrity and insulation is required the coat back may be reduced to 100mm and no coat back is required where 30 minutes integrity and insulation is required. 6. Cables may be individual or bunched where they penetrate the CP 670 Fire Safety System. Certificate No: 090a(9) to LPS 1132: Issue 4
CP657 Blocks with CP651N mastic (wall application) - LPCB Ref. No. 090a(9) Product Name
Element of Construction Orientation
Element of Construction Thickness (mm)
Element of Construction Material
Aperture size
Use
CP657 Blocks with CP615N mastic (1)
Wall
100
Concrete, concrete block or masonry walls minimum density 600 kg/m³
1000mm high x 700mm wide or 700mm high or 1000mm wide
Wall
100
Concrete, concrete block or masonry walls minimum density 600 kg/m³
1000mm high x 700mm wide or 700mm high or 1000mm wide
Steel Cable trays, ladders, trunking and conduit supporting all cables with PVC insulation Steel, Stainless steel & cast iron Pipes max 168mm Ø x 14.2mm thick (100kg/m³ mineral fibre insulation 600 x 40mm thick) (2)
20 Nov 2011
Fire Resistance (min) Intergrity (E) 120
Fire Resistance (min) Insulation (I) 120
120
120
Cert. No.
090a/08
111
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of Construction Orientation
Element of Construction Thickness (mm)
Element of Construction Material
Aperture size
Use
Wall
100
Concrete, concrete block or masonry walls minimum density 600 kg/m³
1000mm high x 700mm wide or 700mm high or 1000mm wide
Wall
100
Concrete, concrete block or masonry walls minimum density 600 kg/m³
1000mm high x 700mm wide or 700mm high or 1000mm wide
Wall
100
Concrete, concrete block or masonry walls minimum density 600 kg/m³
1000mm high x 700mm wide or 700mm high or 1000mm wide
Wall
100
Concrete, concrete block or masonry walls minimum density 600 kg/m³
1000mm high x 700mm wide or 700mm high or 1000mm wide
Steel, Stainless steel & cast iron Pipes max 88.9mm Ø x 14mm thick (45 100kg/m³ Armaflex AF/SH synthetic latex insulation 800 x 9mm thick) (2) Steel, Stainless steel & cast iron Pipes max 88.9mm Ø x 14mm thick (45 100kg/m³ Armaflex AF/SH synthetic latex insulation 800 x 31mm thick) (2) Copper pipes max 88.9mm Ø x 3mm thick (100kg/m³ mineral fibre insulation 800 x 40mm thick) (2 Copper pipes max 54mm Ø x 3mm thick (45 100kg/m³ Armaflex AF/SH synthetic latex insulation 800 x 9 – 31mm thick) (2)
Fire Resistance (min) Intergrity (E) 120
Fire Resistance (min) Insulation (I) 90
120
120
120
120
120
90
Cert. No.
Notes For CP657 Blocks with CP651N mastic (wall application); 1. Hilti CP657 Fire Stop Brick with a minimum thickness of 200mm and a nominal density of 270 ± 30kg/m³. If the minimum thickness of the concrete/masonry wall is 200mm, then the seal may be fitted directly into the opening in the wall. If the thickness is less than 200mm (minimum 100mm for walls) then the opening may either be lined with calcium silicate board, minimum 200mm wide x 25mm thick, or the opening increased to at least 200mm by fitting calcium silicate board, minimum 50mm wide x 25mm thick, around the opening. The board is fastened with steel screws into metal plugs at max 300mm centres. The boards may be fitted to either face of the wall. The calcium silicate board shall be Promatect H or equivalent. 2. The metal pipes shall be fitted with a mineral wool sleeve that is either continuous through the seal or interrupted and butt up to the face of the seal on both faces. 3. All services passing through the penetration seal system must be supported on both sides of the seal within 500mm from the face of the seal so that the weight of the services is not taken by the seal system.
112
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS
Certificate No: 090a(9) to LPS 1132: Issue 4
CP657 Blocks with CP651N mastic (floor application) - LPCB Ref. No. 090a(9) Product Name
Element of Construction Orientation
Element of Construction Thickness (mm)
Element of Construction Material
Aperture size
Use
CP657 Blocks with CP615N mastic (1)
Floor
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
Floor
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
Floor
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
Floor
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
Steel Cable trays, ladders, Trunking and conduit supporting all cables, PVC insulated with copper conductors ≤ 95mm² bunched or un bunched & all cables with aluminium conductors Steel Cable trays, ladders, Trunking and conduit supporting cables with copper conductors ≥ 95mm² with PVC insulation Steel, Stainless steel & cast iron Pipes max 168mm Ø x 14.2mm thick (100kg/m³ mineral fibre insulation 600 x 40mm thick) (2) Steel, Stainless steel & cast iron Pipes max 88.9mm Ø x 14mm thick (45 - 100kg/m³ Armaflex AF/SH synthetic latex insulation 800 x 9mm thick) (2) Steel, Stainless steel & cast iron Pipes max 88.9mm Ø x 14mm thick (45 - 100kg/m³ Armaflex AF/SH synthetic latex insulation 800 x 31mm thick) (2)
Floor
20 Nov 2011
Fire Resistance (min) Integrity (E) 120
Fire Resistance (min) Insulation (I) 120
120
90
120
120
120
90
120
120
Cert. No.
090a/08
113
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of Construction Orientation
Element of Construction Thickness (mm)
Element of Construction Material
Aperture size
Use
Floor
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
Floor
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
Floor
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
Floor
150
Concrete minimum density 600kg/m³
700mm wide x unlimited
Copper pipes max 88.9mm Ø x 3mm thick (100kg/m³ mineral fibre insulation 800 x 40mm thick) (2 Copper pipes max 54mm Ø x 3mm thick (45 - 100kg/m³ Armaflex AF/SH synthetic latex insulation 800 x 9 – 31mm thick) (2) uPVC pipes up to 110mm Ø x 8.2mm thick (1.8mm min wall thickness for pipes ≤ 50mmØ & 2.2mm for pipes ≤ 110mm Ø) (3) HDPE pipes up to 110mm Ø x 10mm thick (2.7mm min wall thickness) (3)
Fire Resistance (min) Integrity (E) 120
Fire Resistance (min) Insulation (I) 120
120
90
120
120
120
120
Cert. No.
Notes For CP657 Blocks with CP651N mastic (floor application); 1. Hilti CP657 Fire Stop Brick with a minimum thickness of 200mm and a nominal density of 270 ± 30kg/m³. If the minimum thickness of the concrete floor is 200mm, then the seal may be fitted directly into the opening in the floor. If the thickness is less than 200mm (minimum 150mm for floors) then the opening may either be lined with calcium silicate board, minimum 200mm wide x 25mm thick, or the opening increased to at least 200mm by fitting calcium silicate board, minimum 50mm wide x 25mm thick, around the opening. The board is fastened with steel screws into metal plugs at max 300mm centres. The boards may be fitted to the upper face of a floor. The calcium silicate board shall be Promatect H or equivalent. When fitted in a partition system, the cavity of the partition is closed around the opening with stud sections on all four sides. The opening is lined with calcium silicate board or a fire rated plaster board (with glass fibre reinforcement), min 200mm wide x 25mm thick. 2. The metal pipes shall be fitted with a mineral wool sleeve that is either continuous through the seal or may be interrupted and butt up to the face of the seal on both faces. 3. A square or ring of steel mesh must be fitted to the soffit of the penetration seal around the pipe. The mesh is typically1.5mm thick with a mesh size of 9mm x 9mm. the width of the mesh is at least 50mm on all sides of the pipe. The mesh is fastened to the CP657 bricks with four steel self tapping screws, nominally M6 x 150mm long, equally spaced around the pipe. 4. All services passing through the penetration seal system must be supported on both sides of the seal within 500mm from the face of the seal so that the weight of the services is not taken by the seal system. Certificate No: 090a(11) to LPS 1132: Issue 4
114
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Penetration Gap seals - CP670 Fire Safety System (unframed double layer 100mm) Product Name
Element of Construction Orientation
CP 670 Fire Safety System (1)
Fire Resistance Integrity (E) 120
Fire Resisitance Insulation (I) 120
Cable Trays 500 x 60 mm (4)(5)
120
120
Cable Trays 300 x 60 mm (4)(5)
120
120
CP644 Collars (surface mounted) pipes 160 mm Ø x 1.8 14.6 mm thick (3) Steel Pipes 32mm Ø x 2.6 – 4.0 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 500 x 30mm thick) (6) Steel Pipes 159 Ø x 4.0 – 14.2 mm thick or 168.3mm Ø x 4.0mm thick (Insulated 40 – 50kg/m² Rockwool 800 mineral fibre jacket 800 x 30mm thick) (6) Steel Pipe 168.3mm Ø x 14.2 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 1000 x 40mm thick) (6)
120
120
120
120
120
120
120
120
Element of Construction Material
Aperture Size
Penetration Type
Floor
Element of Construction Thickness (mm) 150
LW Concrete 650kg/m³
N/A
Floor
150
LW Concrete 650kg/m³
Floor
150
LW Concrete 650kg/m³
Floor
150
LW Concrete 650kg/m³
Floor
150
LW Concrete 650kg/m³
Maximum aperture size 1000 mm wide x 2000 mm long (1). Maximum aperture size 1000 mm wide x 2000 mm long (1). Maximum aperture size 1000 mm wide x 2000 mm long (1). Maximum aperture size 1000 mm wide x 2000 mm long (1). Maximum aperture size 1000 mm wide x 2000 mm long (1).
Floor
150
LW Concrete 650kg/m³
Maximum aperture size 1000 mm wide x 2000 mm long (1).
Floor
150
LW Concrete 650kg/m³
Maximum aperture size 1000 mm wide x 2000 mm long (1).
20 Nov 2011
Cert. No. 090a/10
115
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of Construction Orientation Floor
Element of Construction Thickness (mm) 150
Element of Construction Material
Aperture Size
Penetration Type
LW Concrete 650kg/m³
Maximum aperture size 1000 mm wide x 2000 mm long (1).
Copper Pipe 88.9mm Ø x 1.8 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 800 x 40mm thick) (6)
Fire Resistance Integrity (E) 120
Fire Resisitance Insulation (I) 120
Cert. No.
Notes: 1. CP670 Fire Safety System consists of 2 x 50mm pre-coated CP670 Fire Safety Board’s having a density of 150kg/m3 & coated with CP 670 Fire Safety Coating nominally 1.0mm thick extending beyond the perimeter of the seal onto surface of surrounding construction by 12.5mm unless otherwise stated. 2. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in any manner for the stated period. 3. CP644 Collars are approved surface mounted to the under side of the floor with High Density Polyethylene (PE - HD) & Polyvinyl chloride -Un-plasticised (PVC-U) pipes only. 4. All cables & cable trays required to provide 120 minutes insulation and integrity must include a 150mm coat back of CP670 Fire Safety Coating. 5. Cables may be individual or bunched where they penetrate the CP 670 Fire Safety System. 6. Rockwool Heizungsrohrschale 800 mineral wool insulation (1000mm long x 40mm thick) must be applied from each face of the LW concrete floor. Certificate No: 090a(11) to LPS 1132: Issue 4
Penetration Gap Seals - CP670 Fire Safety System (unframed double layer 100mm) Product Name
Element of Construction Orientation
CP 670 Fire Safety System (1)
116
Element of Construction Material
Aperture Size
Penetration Type
Wall
Element of Construction Thickness (mm) 135
Steel framed drywall partition
N/A
Wall
135
Steel framed drywall partition
Wall
135
Steel framed drywall partition
Wall
135
Steel framed drywall partition
Maximum aperture size 1000 mm wide x 2000 mm high (1). Maximum aperture size 1000 mm wide x 2000 mm high (1). Maximum aperture size 1000 mm wide x 2000 mm high (1). Maximum aperture size 1000 mm wide x 2000 mm high (1).
Fire Resistance Integrity (E) 120
Fire Resistance Insulation (I) 120
Cable Trays 500 x 60 mm (4)(5)
120
120
Cable Trays 300 x 60 mm (4)(5)
120
120
CP644 Collars (surface mounted) pipes 160 mm Ø x 1.8 -14.6 mm thick (3)
120
120
Cert. No. 090a/10
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of Construction Orientation
Element of Construction Material
Aperture Size
Penetration Type
Wall
Element of Construction Thickness (mm) 135
Steel framed drywall partition
Maximum aperture size 1000 mm wide x 2000 mm high (1).
Wall
135
Steel framed drywall partition
Maximum aperture size 1000 mm wide x 2000 mm high (1).
Wall
135
Steel framed drywall partition
Maximum aperture size 1000 mm wide x 2000 mm high (1).
Wall
135
Steel framed drywall partition
Maximum aperture size 1000 mm wide x 2000 mm high (1).
Steel Pipes 32mm Ø x 2.6 – 4.0 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 500 x 30mm thick) (6) Steel Pipes 159 Ø x 4.0 – 14.2 mm thick or 168.3mm Ø x 4.0mm thick Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 800 x 30mm thick) (6) Steel Pipe 168.3mm Ø x 14.2 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 1000 x 40mm thick) (6) Copper Pipe 88.9mm Ø x 1.8 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 800 x 40mm thick) (6)
Fire Resistance Integrity (E) 120
Fire Resistance Insulation (I) 120
120
120
120
120
120
120
Cert. No.
Notes: 1. CP670 Fire Safety System consists of 2 x 50mm pre-coated CP670 Fire Safety B|oard’s having a density of 150kg/m3 & coated with CP 670 Fire Safety Coating nominally 1.0mm thick extending beyond the perimeter of the seal onto surface of surrounding construction by 12.5mm unless otherwise stated. 2. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in any manner for the stated period. 3. CP644 Collars are approved surface mounted to the steel framed drywall partition with High Density Polyethylene (PE - HD) & Polyvinyl chloride -Un-plasticised (PVC-U) pipes only. 4. All cables & cable trays required to provide 120 minutes insulation and integrity must include a 150mm coat back of CP670 Fire Safety Coating. 5. Cables may be individual or bunched where they penetrate the CP 670 Fire Safety System. 6. Rockwool Heizungsrohrschale 800 mineral wool insulation (1000mm long x 40mm thick) must be applied from each face of the partition. Certificate No: 090a(11) to LPS 1132: Issue 4
20 Nov 2011
117
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Penetration Gap Seals - CP670 Fire Safety (unframed single layer 50mm) Product Name
Elements of Construction Orientation
CP 670 Fire Safety System (1)
Element of Construction Material
Aperture Size
Penetration Type
Floor
Element of Construction Thickness (mm) 150
Reinforced concrete
N/A
Floor
150
Reinforced concrete
Floor
150
Reinforced concrete
Maximum aperture size 2200 mm long x 600 mm wide (1). Maximum aperture size 2200 mm long x 600 mm wide (1). Maximum aperture size 2200 mm long x 600 mm wide (1).
Floor
150
Reinforced concrete
Maximum aperture size 2200 mm long x 600 mm wide (1).
Floor
150
Reinforced concrete
Maximum aperture size 2200 mm long x 600 mm wide (1).
Floor
150
Reinforced concrete
Maximum aperture size 2200 mm long x 600 mm wide (1).
Fire Resistance Integrity (E) 60
Fire Resistance Insulation (I) 60
Cable trays up to 500mm wide by 60mm deep (4) (5)
60
60
Steel Pipes up to 168mm Ø x 14.2 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 1000 x 40mm thick) (6) Copper Pipes up to 88.9mm Ø x 2.5 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 1000 x 40mm thick) (6) CP643N Collars (surface mounted) PVC-U pipes 32 - 110 mm Ø and up to 8.2 mm wall thickness (3) CP643N Collars (surface mounted) PE pipes 32 - 110 mm Ø and up to 10 mm wall thickness (3)
60
60
60
60
60
60
60
60
Cert. No. 090a/10
Notes: 1. The CP 670 Fire Safety Board System consists of 1 x 50mm pre-coated mineral wool board having a density of 160kg/m³ & coated with a layer of CP 670 Fire Safety Coating applied to both faces to a thickness of 0.7mm,. The boards were supplied 1200mm long x 600mm wide and were cut to fit. Once in place the boards should be additionally sealed at their edges with CP 606 mastic. Provided the CP 670 Fire Safety Board System is restricted to 600mm wide its length can be unrestricted. 2. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in any manner for the stated period. 3. CP643N Collars are approved surface mounted to the under side of the floor with Polyethylene (PE) & Polyvinyl chloride -Unplasticised (PVC-U) pipes only. 4. All cables & cable trays required to provide 60 minutes insulation and integrity must include a 150mm coat back of CP670 Fire Safety Coating. 5. Cables (15 - 78mm Ø Copper core 1.5 - 185mm² & 52mm Ø Aluminium core 185mm²) may be individual or bunched where they penetrate the CP 670 Fire Safety System. 6. Rockwool Heizungsrohrschale 800 mineral wool insulation (1000mm long x 40mm thick) must be applied from each face of the partition.
118
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS
Certificate No: 090a(11) to LPS 1132: Issue 4
Penetration Gap Seals - CP670 Fire Safety Systems (unframed double layer 100mm) Product Name CP 670 Fire Safety System (1)
Element of Construction Orientation
Element of Construction Thickness (mm) 150
Element of Construction Material
Aperture Size
Penetration Type
Fire Resisitance Integrity (E)
Reinforced concrete
N/A
60
Floor
150
Reinforced concrete
Cable trays up to 500mm wide by 60mm deep (4) (5)
60
60
Floor
150
Reinforced concrete
Maximum aperture size 2100 mm long x 1200 mm wide (1). Maximum aperture size 2100 mm long x 1200 mm wide (1). Maximum aperture size 2100 mm long x 1200 mm wide (1).
Fire Resisitance Insulation (I) 60
60
60
Floor
150
Reinforced concrete
Maximum aperture size 2100 mm long x 1200 mm wide (1).
60
60
Floor
150
Reinforced concrete
Maximum aperture size 2100 mm long x 1200 mm wide (1).
60
60
Floor
150
Reinforced concrete
Maximum aperture size 2100 mm long x 1200 mm wide (1).
Steel Pipes up to 168mm Ø x 14.2 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 1000 x 40mm thick) (6) Copper Pipes up to 88.9mm Ø x 2.5 mm thick (Insulated with 40 – 50kg/m² Rockwool 800 mineral fibre jacket 1000 x 40mm thick) (6) CP643N Collars (surface mounted) PVC-U pipes 32 - 160 mm Ø and up to 11.9 mm wall thickness (3) CP643N Collars (surface mounted) PE pipes 32 160 mm Ø x up to 14.6 mm wall thickness (3)
60
60
Floor
Cert. No. 090a/10
Notes: 1. The CP 670 Fire Safety Board System consists of 2 x 50mm pre-coated mineral wool board having a density of 160kg/m³ & coated with a layer of CP 670 Fire Safety Coating applied to both faces to a thickness of 0.7mm. The boards were supplied 1200mm long x 600mm wide and were cut to fit. Once in place the boards should be additionally sealed at their edges with CP 606 mastic. Provided the CP 670 Fire Safety Board System is restricted to 1200mm wide its length can be unrestricted. 2. It is assumed that all penetrating services are effectively independently supported such that their weight does not act on the seal in any manner for the stated period. 3. CP643N Collars are approved surface mounted to the under side of the floor with Polyethylene (PE) & Polyvinyl chloride -Unplasticised (PVC-U) pipes only.
20 Nov 2011
119
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS 4. All cables & cable trays required to provide 60 minutes insulation and integrity must include a 150mm coat back of CP670 Fire Safety Coating. 5. Cables (15 - 78mm Ø Copper core 1.5 - 185mm² & 52mm Ø Aluminium core 185mm²) may be individual or bunched where they penetrate the CP 670 Fire Safety System. 6. Rockwool Heizungsrohrschale 800 mineral wool insulation (1000mm long x 40mm thick) must be applied from each face of the floor.
MCT Brattberg AB SE 37192 Karlskrona, Sweden Tel: +46 (0) 455 451 60 • Fax: +46 (0) 455 451 28 E-mail: [email protected] • Website: www.mctbrattberg.com UK Office: MCT Brattberg Ltd, Commerce Street, Carrs Industrial Estate, Haslingden BB4 5JT, United Kingdom Tel: +44 (0)1706 244890 • Fax: +44 (0)1706 244891 E-mail: [email protected] • Website: www.mctbrattberg.co.uk
Certificate No: 628a to LPS 1132: Issue 4 Product Name
Use
Element of Construction
RGB 2, 4, 6, 8 & RGB 180, 240 & 360
Cables
Concrete or masonry Floor Concrete or masonry Floor Concrete or masonry Wall Concrete or masonry Wall Concrete or masonry Floor Concrete or masonry Floor Concrete or masonry Wall Concrete or masonry Wall Concrete or masonry Floor Concrete or masonry Floor Concrete or masonry Wall Concrete or masonry Wall Concrete or masonry Floor Concrete or masonry Floor Concrete or masonry Wall Concrete or masonry Wall
Steel pipes Cables Steel pipes RGBO 2, 4, 6, 8 & RGBO 180, 240 & 360
Cables Steel pipes Cables Steel pipes
RGP 50, 70, 100, 150, 200 & 300
Cables Steel pipes Cables Steel pipes
RGPO 50, 70, 100, 150, 200 & 300
Cables Steel pipes Cables Steel pipe
Fire Resistance (min) Integrity 240
Fire Resistance (min) Insulation 120
240
60
240
60
240
60
240
120
240
60
240
60
240
60
360
120
240
60
360
120
240
60
360
120
240
60
360
120
240
60
Cert. No. 628a/01
628a/02
628a/03
628a/04
Note: Please refer to manufacturer’s product data for maximum aperture sizes and installation details.
120
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022b(3) to LPS 1132: Issue 4 Product Name
Application
Cavity Width (mm)
Barrier Size (mm)
Rockwool Firepro™ TCB Cavity Barrier
Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Masonry/timber frame and masonry cavity walls Timber frame Timber frame Timber frame Timber frame Timber frame
50 - 55
Fire Resisitance (min) Insulation 30
56 - 65
75 x 75
60
30
66 - 75
85 x 85
60
30
76 - 80
90 x 90
60
30
81 - 90
100 x 100
60
30
91 - 100
110 x 110
60
30
101 110
120 x 120
60
30
111 120
130 x 130
60
30
121 130
140 x 140
60
30
131 140
150 x 150
60
30
50 - 55 56 - 65 66 - 75 76 - 80 81 - 90
65 x 65 75 x 75 85 x 85 90 x 90 100 x 100 110 x 110 120 x 120 130 x 130 140 x 140 150 x 150 75 x 75 75 x 75
30 30 30 30 30
30 30 30 30 30
30
30
30
30
30
30
30
30
30
30
60 60
30 30
Timber frame
91 - 100
Timber frame
101 110 111 120 121 130 131 140 50 - 55 56 - 65
Timber frame Timber frame Timber frame Timber frame Timber frame
20 Nov 2011
65 X 65
Fire Resistance (min) Integrity 60
Cert. No. 022b/04
121
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Application
Cavity Width (mm)
Barrier Size (mm)
Timber frame Timber frame Timber frame
66 - 75 76 - 80 81 - 90
Timber frame
91 - 100
Timber frame
Timber frame
101 110 111 120 121 130 131 140 81 - 90
Timber frame
91 - 100
Timber frame
101 110 111 120 121 130
85 x 85 90 x 90 100 x 100 110 x 110 120 x 120 130 x 130 140 x 140 150 x 150 100 x 100 110 x 110 120 x 120 130 x 130 140 x 140
Timber frame Timber frame Timber frame
Timber frame Timber frame
Fire Resistance (min) Integrity 60 60 60
Fire Resisitance (min) Insulation 30 30 30
60
30
60
30
60
30
60
30
60
30
60
60
60
60
60
60
60
60
60
60
Cert. No.
Notes: 1. Rockwool Firepro™ TCB Cavity Barrier is designed for use between the leaves of a masonry cavity wall, timber frame construction, or between a timber frame inner leaf and masonry outer leaf. 2. Barriers can be installed vertically or horizontally. 3. Refer to manufacturer’s technical literature for fixing details. Certificate No: 022b(1) to LPS 1132: Issue 4 Product Name
Cavity Width (mm)
Slab Size (mm)
Rockwool Firepro™ SP 60 Firestop Slab Rockwool Firepro™ SP 120 Firestop Slab
50 - 400 50 - 400
900 x 650 x 75 900 x 650 x 90
Fire Resistance (min) Integrity 60 120
Fire Resistance (min) Insulation 60 120
Cert. No.
022b/01 022b/02
Notes: 1. This product is suitable for sealing gaps between a concrete or composite concrete/metal floors and an adjacent masonry, cladding/panel system with non-combustible core or curtain wall, or between the leaves of a masonry cavity wall. 2. For cavity widths of 250mm or more, joints between adjacent lengths of firestops should be sealed on the top surface with aluminium foil tape. 3. Refer to manufacturer's technical literature for fixing details. Certificate No: 022b(2) to LPS 1132: Issue 4 Product Name
Product Type(s)
Wall Width (mm)
Firestop Width (mm)
Application
Rockwool Firepro Linear and Trapezoidal Firestop Systems
Trapezoidal Firestop 3B & Linear Firestop 2
100
100
Trapezoidal Firestop 3B & Linear Firestop 2
150
150
Profiled metal deck over block work wall, with profile running across or along the wall Profiled metal deck over block work wall, with profile running across or along the wall
122
Fire Resistance (min) Integrity 120
Fire Resistance (min) Insulation 120
180
180
Cert. No. 022b/03
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
20 Nov 2011
Product Type(s)
Wall Width (mm)
Firestop Width (mm)
Application
Trapezoidal Firestop 3B & Linear Firestop 2
200
200
Trapezoidal Firestop 3B & Linear Firestop 2
100
100
Trapezoidal Firestop 3B & Linear Firestop 2
150
150
Trapezoidal Firestop 3B & Linear Firestop 2 Trapezoidal Firestop 3B & Linear Firestop 2
150
150
200
200
Trapezoidal Firestop 3B & Linear Firestop 2
100
100
Trapezoidal Firestop 3B & Linear Firestop 2
150
150
Trapezoidal Firestop 3B & Linear Firestop 2
200
200
Trapezoidal Firestop 3B
N/A
100
Trapezoidal Firestop 3B
N/A
150
Trapezoidal Firestop 3B
N/A
200
Linear Firestop 2
100
100
Linear Firestop 2
150
150
Linear Firestop 2
200
200
Profiled metal deck over blockwork wall, with profile running across or along the wall Profiled metal deck with lightweight concrete over wall, with profile running across or along the wall Profiled metal deck with lightweight concrete over wall, with profile running across the wall Profiled metal deck with lightweight concrete over wall, with profile running along the wall Profiled metal deck with lightweight concrete over wall, with profile running across or along the wall (1) Profiled metal deck with or without lightweight concrete over Steel Universal Beam, with profile running across the beam. (1) Profiled metal deck with or without lightweight concrete over Steel Universal Beam, with profile running across the beam. (1) Profiled metal deck with or without lightweight concrete over Steel Universal Beam, with profile running across the beam. (1) Profiled metal deck with or without lightweight concrete over Steel Universal Beam, with profile running across the beam. (1) Profiled metal deck with or without lightweight concrete over Steel Universal Beam, with profile running across the beam. (1) Profiled metal deck with or without lightweight concrete over Steel Universal Beam, with profile running across the beam. (1) Concrete deck over Blockwork wall Concrete deck over Blockwork wall Concrete deck over Blockwork wall
Fire Resistance (min) Integrity 240
Fire Resistance (min) Insulation 240
120
120
180
180
240
240
240
240
120
120
180
180
240
240
120
120
180
180
240
240
120
120
180
180
240
240
Cert. No.
123
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
124
Product Type(s)
Wall Width (mm)
Firestop Width (mm)
Application
Trapezoidal Firestop 3B & Linear Firestop 2
100
100
Trapezoidal Firestop 3B & Linear Firestop 2
150
150
Trapezoidal Firestop 3B & Linear Firestop 2
200
200
Linear Firestop 3A
100
300
Linear Firestop 3A
150
300
Linear Firestop 3A
200
300
Linear Firestop 3A
100
400
Linear Firestop 3A
150
400
Linear Firestop 3A
200
400
Linear Firestop 3A & Trapezoidal Firestop 3B
100
200
Linear Firestop 3A & Trapezoidal Firestop 3B
150
200
Linear Firestop 3A & Trapezoidal Firestop 3B
200
200
Linear Firestop 3A & Trapezoidal Firestop 3B
100
300
Linear Firestop 3A & Trapezoidal Firestop 3B
150
300
Linear Firestop 3A & Trapezoidal Firestop 3B
200
300
Profiled concrete deck over blockwork wall, with profile running across or along the wall. Profiled concrete deck over blockwork wall, with profile running across or along the wall. Profiled concrete deck over blockwork wall, with profile running across or along the wall. Concrete deck over blockwork wall, with extended firestopping (2) Concrete deck over blockwork wall, with extended firestopping (2) Concrete deck over blockwork wall, with extended firestopping (2) Concrete deck over blockwork wall, with extended firestopping (2) Concrete deck over blockwork wall, with extended firestopping (2) Concrete deck over blockwork wall, with extended firestopping (2) Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2) Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2) Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2) Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2) Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2) Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2)
Linear Firestop 3A & Trapezoidal Firestop 3B
100
400
Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2)
Fire Resistance (min) Integrity 120
Fire Resistance (min) Insulation 120
240
240
240
240
180
180
240
240
240
240
180
180
240
240
240
240
180
180
180
180
240
240
180
180
240
240
240
240
180
180
Cert. No.
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Product Type(s)
Wall Width (mm)
Firestop Width (mm)
Application
Linear Firestop 3A & Trapezoidal Firestop 3B
150
400
Linear Firestop 3A & Trapezoidal Firestop 3B
200
400
Linear Firestop 3A & Trapezoidal Firestop 3B Linear Firestop 3A & Trapezoidal Firestop 3B Linear Firestop 3A & Trapezoidal Firestop 3B Linear Firestop 3A & Trapezoidal Firestop 3B
100
400
150
400
200
400
100
400
Linear Firestop 3A & Trapezoidal Firestop 3B
150
400
Linear Firestop 3A & Trapezoidal Firestop 3B
200
400
Linear Firestop 2
100
100
Linear Firestop 2
150
150
Linear Firestop 2
200
200
Trapezoidal Firestop 3B & Linear Firestop 2
100
100
Trapezoidal Firestop 3B & Linear Firestop 2
150
150
Trapezoidal Firestop 3B & Linear Firestop 2
200
200
Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2) Profiled Metal deck over blockwork wall with extended firestopping, with profile running across the wall. (2) Profiled metal deck with lightweight concrete over block wall, with the profile running across the wall. (2) Profiled metal deck with lightweight concrete over block wall, with the profile running across the wall. (2) Profiled metal deck with lightweight concrete over block wall, with the profile running across the wall. (2) Profiled Deck over blockwork wall with Asymmetrical profiles, with the profile running along the wall. (2) Profiled Deck over blockwork wall with Asymmetrical profiles, with the profile running along the wall. (2) Profiled Deck over blockwork wall with Asymmetrical profiles, with the profile running along the wall. (2) Concrete deck over blockwork wall Concrete deck over blockwork wall Concrete deck over blockwork wall Profiled metal deck with lightweight concrete over wall, with the profile running across the wall Profiled metal deck with lightweight concrete over wall, with the profile running across the wall Profiled metal deck with lightweight concrete over wall, with the profile running across the wall
Fire Resistance (min) Integrity 240
Fire Resistance (min) Insulation 240
240
240
180
180
240
240
240
240
180
180
240
240
240
240
120
0
180
0
240
0
120
0
180
0
240
0
Cert. No.
Notes: 1. The fire resistance of the BeamClad or ColumnClad system used for the fire protection of the beam must be the same as the fire resistance of the Linear and Trapezoidal Firestop systems. Where the beam has a wall underneath, the gap between the beam casing and the top of the wall should be packed with linear Firestop 2. 2. Extended firestopping may need to be supported by fire resistant fixings to soffits to avoid edge sag, depending on overhang and soffit flatness. Supports are essential for extensions greater than 100mm. 3. Where Linear Firestop 2 is used it must be compressed by at least 5% & where Trapezoidal Firestop 3B is used it must be tightly and accurate fit into trapezoidal profile. 4. Where fire ratings apply to gaps over walls they must be constructed of dense aggregate blocks, lightweight aggregate concrete, clay bricks, or concrete blocks, which have a density of 400 Kg/m³ or greater. 5. The maximum gap size allowed between the top of the wall and the soffit of the deck/floor is the thickness of the wall. 6. Refer to manufacturer's technical literature for fixing details
20 Nov 2011
125
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS
Certificate No: 022b(4) to LPS 1132: Issue 4 Product Name
Element of Construction Orientation
Element of Construction Thickness (mm)
Element of Construction Material
Maximum Joint Width (mm)
Configuration: Fire Side Depth of Sealant (mm)
Configuration: Backing Material
FirePro ™ Acoustic Intumescent Sealant
floor
230
AC/AC
50
25
floor
230
Softwood/AC
25
12
floor
230
Hardwood/AC
50
25
floor
230
Steel/AC
50
25
floor
250
AC/AC
30
15
floor
250
AC/AC
15
10
floor
250
AC/AC
20
floor
250
AC/AC
50
floor
250
AC/AC
10
floor
250
AC/AC
25
floor
250
Hardwood/AC
15
10
floor
250
Steel/AC
15
10
wall
150
AC/AC
30
30
wall
150
AC/AC
15
15
wall
150
AC/AC
10
10
wall
150
AC/AC
10
10
wall
150
AC/AC
15
15
wall
150
AC/AC
30
30
wall
200
AC/AC
50
25
wall
200
Hardwood/AC
50
25
wall
200
Softwood/AC
25
12
wall
200
Steel/AC
50
25
wall
215
AC/AC
30
15
wall
215
AC/AC
15
10
wall
215
Hardwood/AC
15
10
wall
215
Steel/AC
15
10
wall
250
AC/AC
20
wall
250
AC/AC
40
wall
250
AC/AC
10
wall
250
AC/AC
25
Configuration: Non-fire Side Depth of Sealant Configeration: Non-fire Side Depth of Sealant (mm)
Fire Resistance (mm) Integrity (E)
Fire Resistance (mm) Insulation (I)
Cert. No.
Ethafoam 50mm
155
105
022b/05
Ethafoam 0mm Ethafoam 50mm Ethafoam 50mm Ethafoam 40mm Ethafoam mm Polyethylene 20mm Polyethylene 50 x 25mm Polyethylene 0mm Polyethylene 25mm Ethafoam 15mm Ethafoam 25mm Polyethylene 15 x 15 Polyethylene 10 x 10 Polyethylene 10 x 15 Polyethylene 10 x 15 Polyethylene 15 x 15 Polyethylene 30 x 15 Ethafoam 50mm Ethafoam 50mm Ethafoam 30mm Ethafoam 50mm Ethafoam 40mm Ethafoam 25mm Ethafoam 25mm Ethafoam 25mm Polyethylene 20mm Polyethylene 40mm Polyethylene 10mm Polyethylene 25mm
51
44
47
47
72
62
243
65
243
29
10
155
47
25
240
92
6
240
207
15
240
73
53
53
243
29
30
265
265
15
265
230
10
265
265
200
166
227
227
240
233
245
82
96
93
55
54
77
39
243
44
243
29
40
29
243
16
10
240
122
20
240
95
10
240
240
20
240
126
Note: AC - Aerated Concrete. Ethafoam - Open cell polyethylene foam rod Please refer to Rockwool installation instructions for further details Certificate No: 022b(5) to LPS 1132: Issue 4
126
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Rockwool FirePro Ablative Coated Batt - Pipe Penetration Product Name
Element of Construction Orientation
Rockwool FirePro Ablative Coated Batt
Wall
Element of Construction Thickness (mm) 150
Wall
150
Wall
150
Wall
150
Wall
150
Wall
150
Wall
150
Wall
150
Wall
150
Wall
150
Wall
150
Wall
150
20 Nov 2011
O/D wall thickness range (mm) 27 / 2.5 to 110 / 12
Fire Resistance Integrity / Insulation 120 / 60
PVC
19 / 1.9 to 55 / 2.2
90 / 60
Rockwool Insulated Fire Sleeve(7)
PVC
>55 / 2.2 to 110 / 8.9
60 / 60
1 x 60mm
Rockwool Insulated Fire Sleeve(7)
PVC
110 / < 3.6
120 / 30
1200 x 600
1 x 60mm
Rockwool Insulated Fire Sleeve(7)
HDPE
110 / 4.2 to 160 / 6.2
90 / 60
1200 x 600
1 x 60mm
Rockwool Insulated Fire (7) Sleeve
PP
>22 / 1.2 to 160 / 10
60 / 60
1200 x 600
1 x 60mm
Rockwool Insulated Fire Sleeve(7)
PP
22 / 1.2
120 / 120
1200 x 600
1 60mm
Unlagged(8)
Steel
17.1 / 2.3 to 168.3 / 7.1
120 / 0
1200 x 600
1 x 60mm
Unlagged(8)
Copper
15.0 / 0.7 to 108 / 1.5
120 / 0
1200 x 600
1 x 60mm
Lagged with Fire Tube/ Conlit pipe sections
Steel
88.9 / 4.0 to 164 / 6.4
120 / 60
1200 x 600
1 x 60mm
Lagged with Fire Tube/Conlit pipe sections
Copper
15.0 / 0.5 to 108 / 1.5
120 / 60
1200 x 600
1 x 60mm
Lagged with Fire Tube/Conlit pipe sections
Copper
50 / 1.8
120 / 120
Element of Construction Material
Aperture Size (mm)
Coated Batt (layers & Thickness) 1 x 30mm
Seal Detail
Penetration Type
Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction
1200 x 600
Rockwool Insulated Fire Sleeve
ABS
1200 x 600
1 x 60mm
Rockwool Insulated Fire Sleeve(7)
1200 x 600
1 x 60mm
1200 x 600
Cert. No.
022b/06
127
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS Product Name
Element of Construction Orientation
Element of Construction Material
Aperture Size (mm)
Wall
Element of Construction Thickness (mm) 150
Block work or Concrete Wall
1200 x 600
Wall
150
1200 x 600
Wall
150
Wall
150
240min Block work or Concrete wall 240min Block work or Concrete wall 240min Block work or Concrete wall
Wall
150
Wall
Coated Batt (layers & Thickness) 1 x 60mm
Seal Detail
Penetration Type
Steel
1 x 60mm
Lagged with 500mm long x 40 thick Rockwool 800 insulation or Lagged with Fire Tube/Conlit pipe sections Unlagged(8)
1200 x 600
1 x 60mm
Unlagged
1200 x 600
1 x 60mm
240min Block work or Concrete wall
1200 x 600
1 x 60mm
Copper
15.0 / 0.7 to 108 / 1.5
240 / 60
200
240min Block work or Concrete wall
1200 x 600
Steel
17.1 / 2.3 to 168.3 / 7.1
240 / 0
Wall
215
240min Block work or Concrete wall
1200 x 600
Unlagged(8)
Steel
17.1 / 2.3 to 168.3 / 7.1
240 / 0
Wall
200
240min Block work or Concrete wall
1200 x 600
Unlagged(8)
Copper
15.0 / 0.7 to 108 / 1.5
240 / 0
Wall
200
240min Block work or Concrete wall
1200 x 600
2 x 50mm (with 100mm air gap) 2 x 60mm (with 85 mm air gap) 2 x 50mm (with 100mm air gap) 2 x 50mm (with 100mm air gap)
Lagged with Fire Tube/Conlit pipe sections Lagged with Fire Tube/Conlit pipe sections Unlagged(8)
Steel
17.1 / 2.3 to 168.3 / 7.1
180 / 120
Wall
200
240min Block work or Concrete wall
1200 x 600
2 x 50mm (with 100mm air gap)
Copper
15.0 / 0.7 to 108 / 1.5
240 / 60
Floor
150
240min Concrete Floor
1200 x 600
1 x 60mm
Lagged with Fire Tube/Conlit pipe sections Lagged with Fire Tube/Conlit pipe sections Unlagged(8)
Steel
240 / 0
Floor
150
240min Concrete Floor
1200 x 600
1 x 60mm
Unlagged(8)
Copper
Floor
150
240min Concrete Floor
1200 x 600
1 x 60mm
Steel
Floor
150
240min Concrete Floor
1200 x 600
1 x 60mm
Lagged with Fire Tube/Conlit pipe sections Lagged with Fire Tube/Conlit pipe sections
17.1 / 2.3 to 168.3 / 7.1 15.0 / 0.7 to 108 / 1.5 17.1 / 2.3 to 168.3 / 7.1
(8)
O/D wall thickness range (mm) 88.9 / 4.0 to 170 / 8.0
Fire Resistance Integrity / Insulation 120 / 120
Steel
17.1 / 2.3 to 168.3 / 7.1
240 / 0
Copper
15.0 / 0.7 to 108 / 1.5 17.1 / 2.3 to 168.3 / 7.1
240 / 0
Steel
Copper
15.0 / 0.7 to 108 / 1.5
Cert. No.
180 / 120
(6)
(6)
240 / 0 240 / 120
240 / 120
Notes 1. The Fire Performance of the system will be dependant on the seal detail and Pipe type/ diameter. References should be made to manufactures literature and Chiltern International Fire Ltd Assessment Report: Chilt/A08152 rev B for further information. 2. For Lightweight flexible wall constructions the partition must be a minimum overall thickness of 130mm and be faced on each side with two layers of type F 15mm thick fire rated plasterboard or equivalent 3. For Rigid wall constructions comprising of 150mm, 200mm or 215mm thick lightweight aerated concrete or block work shall have a minimum density of 750kg/m³. 4. For Rigid floor constructions comprising of 150mm lightweight aerated concrete shall have a minimum density of 800kg/m³. 5. Rockwool FirePro Ablative Coated batt has a density of 180kg/m³ comprising of a rock fibre core coated on both faces with 0.6 0.8mm thick (1mm max) Rockwool FirePro Ablative coating, friction fitted centrally within the thickness of the wall and sealed to the construction on both faces with a 30mm x 30mm fillet of Rockwool Acoustic Intumescent Sealant. 6. 120 minutes insulation performance can be achieved using 50mm thick Fire Tube/Conlit seals. 7. Rockwool Insulated Fire sleeves must be fitted on all plastic pipes (30mm thick for pipe Ø up to 110mm and 35mm thick for pipe Ø above 110mm) as they pass by the Rockwool Ablative coated batt and protrude from each face by 45mm. The sleeve shall be sealed into position with a 15mm x 15mm fillet of Rockwool Acoustic Intumescent sealant on each face. 8. Unlagged metal pipes must be sealed with Rockwool Acoustic and Intumescent sealant on both sides of the penetration.
128
20 Nov 2011
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS
Certificate No: 022b(5) to LPS1132: Issue 4
Rockwool FirePro Ablative coated Batt - Cable Penetrations Product Name
Element of Constuction Orientation
Element of Construction Thickness (mm)
Element of Construction Material
Aperture Size (mm)
Coated Batt (Layers & Thickness) 1 x 60mm
Seal Details
Sheathed Cables / Unsheathed Cables Type
Cable Diameter (mm)
Fire Resisitance Integrity / Insulation
Cert. No.
Rockwool FirePro Ablative Coated Batt
Wall
150
1200 x 600
Wall
150
Wall
150
Wall
150
Wall
150
Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction Block work/Concrete wall or 120min Lightweight flexible supporting construction 240min Block work or Concrete wall
4mm conlit bandage
All Sheathed Cabel types
< 21
120 / 60
022b/06
Wall
150
240min Block work or Concrete wall
1200 x 600
Wall
150
240min Block work or Concrete wall
1200 x 600
Wall
150
240min Block work or Concrete wall
1200 x 600
Wall
150
240min Block work or Concrete wall
1200 x 600
Wall
150
240min Block work or Concrete wall
1200 x 600
Floor
150
Floor
150
240min Concrete Floor 240min Concrete Floor
1200 x 600 1200 x 600
Floor
150
240min Concrete Floor
1200 x 600
1 x 6mm
4mm Conlit bandage
Floor
150
240min Concrete Floor
1200 x 600
1 x 60mm
4mm Conlit bandage
Wall
150
1200 x 600
1 x 60mm
4mm Conlit bandage
Wall
150
240min Concrete or Block work Wall 120min lightweight flexible supporting construction
1200 x 600
1 x 60mm
4mm Conlit bandage
(6)
1200 x 600
1 x 60mm
4mm Conlit bandage
PVC Sheathed Cable types
50
120 / 60
1200 x 1200
1 x 60mm
4mm Conlit bandage
All Sheathed Cable types
< 21
90 / 60
1200 x 1200
1 x 60mm
4mm Conlit bandage
PVC Sheathed Cable types
50
90 / 60
1200 x 600
1 x 60mm or 2 x 50mm (100mm air gap) 1 x 60mm or 2 x 50mm (100mm air gap) 1 x 60mm or 2 x 50mm (100mm air gap) 1 x 60mm or 2 x 50mm (100mm air gap) 1 x 60mm or 2 x 50mm (100mm air gap) 1 x 60mm or 2 x 50mm (100mm air gap) 1 x 60mm
4mm Conlit bandage
All Sheathed Cable types
< 21
120 / 60
6mm Conlit bandage (7)
All Sheathed Cable types
< 21
240 / 120
4mm Conlit bandage
All Sheathed Cable types
22 to 50
60 / 60
6mm Conlit bandage (7)
All Sheathed Cable types
22 to 50
240 / 60
6mm Conlit bandage (7)
All Sheathed Cable types
51 to 80
120 / 60
Rockwool Acoustic Intumescent Sealant fillet 6mm Conlit bandage (7) 4mm Conlit bandage
All Sheathed Cable types
< 21
120 / 60
All Sheathed Cable types All Sheathed cables (excluding telecoms cables) Sheathed telecoms cables PVC Unsheathed cable types PVC Unsheathed cable types
< 21
240 / 60
< 21
240 / 60
< 21
120 / 60
10 to 24
240 / 30
10 to 24
120 / 30
10 to 24
120 / 30
1 x 6mm
PVC Unsheathed cable types
Notes 1. The Fire Performance of the system will be dependant on the seal detail and cable type/ diameter. References should be made to manufactures literature and Chiltern International Fire Ltd Assessment Report: Chilt/A08152 rev B for further information. 2. For Lightweight flexible wall constructions the partition must be a minimum overall thickness of 130mm and be faced on each side with two layers of type F 15mm thick fire rated plasterboard or equivalent 3. For Rigid wall constructions comprising of 150mm, 200mm or 215mm thick lightweight aerated concrete or block work shall have a minimum density of 750kg/m³.
20 Nov 2011
129
PART 1: SECTION 3 LPS 1132 WALL & FLOOR PENETRATION AND LINEAR GAP SEALS 4. For Rigid floor constructions comprising of 150mm lightweight aerated concrete shall have a minimum density of 800kg/m³. 5. Rockwool Ablative Coated batt has a density of 180kg/m³ comprising of a rock fibre core coated on both faces with 0.6 - 0.8mm thick (1mm max) Rockwool FirePro Ablative coating, friction fitted centrally within the thickness of the wall and sealed to the construction on both faces with a 30mm x 30mm fillet of Rockwool Acoustic Intumescent Sealant. 6. All Cables shall be supported by steel ladders up to 340mm wide x 80mm deep or steel trays (perforated and un-perforated) up to 460mm wide x 25mm deep at all performance periods. 7. An Integrity performance of 240 minutes can be achieved if a 6 x 1mm layer Conlit ‘bandage’ is used which extends 300mm from each face of the Rockwool Ablative Coated batt. 8. Cables may be individual or bundled where they penetrate the Rockwool FirePro Ablative Coated Batt system. Cable bundles are limited dependant on size and type of cables and sealing method, reference must be made to Chiltern International Fire Ltd Assessment Report: Chilt/A08152 rev B for details.
Certificate No: 022b(5) to LPS 1132: Issue 4
Rockwool Ablative Coated Batt - Blank Seals Product Name
Element of Construction Orientation
Rockwool FirePro Ablative Coated Batt
Wall
Element of Construction Thickness (mm) 150
Floor
150
Wall
215
Wall
130 (Minimum)
Element of Construction Material
Aperture Size (mm)
Lightweight block work wall Lightweight aerated concrete floor Masonry wall
120 minute plasterboard partition
600 x 600
Coated Batt (Layers & Thickness) 1 x 50mm
Fire Resistance Integrity / Insulation 240 / 30
600 x 600
1 x 50mm
240 / 120
1200 x 600
2 x 50mm (with 100mm air gap) 1 x 60mm
240 / 240
1200 x 600
Cert. No. 022b/06
120 / 120
Notes 1. Rockwool Ablative Coated batt has a density of 180kg/m³ comprising of a rock fibre core coated on both faces with 0.6 - 0.8mm thick (1mm max) Rockwool FirePro Ablative coating, friction fitted centrally within the thickness of the wall and sealed to the construction on both faces with a 30mm x 30mm fillet of Rockwool Acoustic Intumescent Sealant. 2. For Rigid wall constructions comprising of 150mm or 215mm thick lightweight aerated concrete or block work shall have a minimum density of 750kg/m³. 3. For Rigid floor constructions comprising of 150mm lightweight aerated concrete shall have a minimum density of 800kg/m³.
130
20 Nov 2011
PART 1: SECTION 4 STRUCTURAL STEEL FIRE PROTECTION
The protection of the structural integrity of a building is important for life safety of the occupants, fire fighters and for the cost-effective repair of the building post fire. When a building is involved in a fire, structural steelwork can resist the damaging effects of the high temperatures generated if suitably protected.
20 Nov 2011
131
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS
This section covers structural steel fire protection with use of board or cementitious coverings approved to LPS 1107 Requirements, Tests and Methods of Assessment of Passive Fire Protection Systems for Structural Steelwork.
British Gypsum Head Office, East Leake, Loughborough, Leicester LE12 6HX, United Kingdom Tel: +44 ( 0)844 8001991 • Fax: +44 (0)844 5618816 E-mail: [email protected] • Website: www.british-gypsum.com Certificate No: 162a to LPS 1107: Issue 1 Product Name
Exposure
Board Thickness (mm)
15
Performance at a critical steel temperature 5500c Hp/A 30min 260
Performance at a critical steel temperature 5500c Hp/A 60min 260
Performance at a critical steel temperature 5500c Hp/A 90min 105
Performance at a critical steel temperature 5500c Hp/A 120 min 65
Glasroc F FIRECASE
Internal only Internal only Internal only Internal only Internal only
20
260
260
180
90
25
260
260
260
100
30
260
260
260
250
35
260
260
260
260
Cert. No.
162a/01
Note: The 30mm and 35mm thickness of protection can be in two separately fixed layers, i.e., 15mm + 15mm and 15mm + 20mm.
Promat UK Ltd The Sterling Centre, Eastern Road, Bracknell, Berkshire RG12 2TD, United Kingdom Tel: +44 (0)1344 381 300 • Fax: +44 (0)1344 381 301 Website: www.promat-spray.co.uk Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting I section beams and H section columns at a critical temperature of 350ºC Product Name
Section Factor (Hp/A)
Cafco 300
132
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 14
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of: 120 min 19
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 27
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 35
40 50 60 70 80 90 100 110 120 130 140
12 12 12 12 12 12 12 12 12 12 12
12 14 15 16 17 18 19 19 20 20 21
17 19 21 23 24 25 26 27 28 29 29
22 25 27 29 31 33 34 35 36 37 38
32 36 40 43 45 48 50 51 53 54 55
42 48 52 56 60 62 65 67 69 71 -
Cert. No.
762b/01
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12 13 13 13 13 13 13 14 14 14 14 14 14 14 14 14 14 14
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 21 22 22 22 22 23 23 23 23 24 24 24 24 24 24 25 25 25
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 30 30 31 31 32 32 33 33 33 33 34 34 34 34 35 35 35 35
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of: 120 min 39 39 40 41 41 42 42 43 43 43 44 44 44 44 45 45 45 45
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 56 57 58 59 60 61 61 62 62 63 63 64 64 65 65 65 66 66
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min -
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting I section beams and H section columns at a critical temperature of 400ºC Product Name
Section Factor (Hp/A)
Cafco 300
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 16
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 22
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 29
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300
12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 13 14 14 14 14 14 14 14 14 14 15
12 12 14 15 16 16 17 18 18 19 19 20 20 20 21 21 21 21 22 22 22 22 22 23 23 23 23
15 17 19 20 21 23 23 24 25 26 26 27 27 28 28 29 29 29 30 30 30 30 31 31 31 31 32
19 22 24 26 27 29 30 31 32 33 33 34 35 35 36 36 37 37 38 38 38 39 39 39 40 40 40
27 31 34 36 39 41 42 44 45 47 48 49 50 50 51 52 53 53 54 54 55 55 56 56 56 57 57
35 40 44 47 50 53 55 57 59 60 62 63 64 65 66 67 68 69 70 70 71 72 72 -
20 Nov 2011
Cert. No.
762b/01
133
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
310 320
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 15 15
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 23 23
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 32 32
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 40 40
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 57 58
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min -
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting I section beams with H section coloumns at a critical temperature of 450ºC Product Name
Section Factor (Hp/A)
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 15
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 21
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 27
Cafco 300
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 13 13 13 13 13 13 13
12 12 13 14 14 15 16 16 17 17 18 18 19 19 19 19 20 20 20 20 20 21 21 21 21 21 21 22 22
14 16 17 19 20 21 22 23 23 24 25 25 26 26 26 27 27 27 28 28 28 28 29 29 29 29 29 30 30
18 20 22 24 25 27 28 29 30 31 31 32 33 33 34 34 35 35 35 36 36 36 37 37 37 37 38 38 38
25 29 32 34 36 38 40 41 42 44 45 46 47 47 48 49 49 50 50 51 51 52 52 53 53 53 54 54 54
33 37 41 44 47 49 52 54 55 57 58 59 61 62 62 63 64 65 66 66 67 67 68 69 69 69 70 70 71
Cert. No.
762b/01
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
134
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Cafco 300, required thickness when protection I section beams and H section columns at a critical temperature of 500ºC Product Name
Section Factor (Hp/A)
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 13
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 19
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 25
Cafco 300
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 13 14 14 15 15 16 16 17 17 17 17 18 18 18 18 19 19 19 19 19 19 20 20 20 20
13 14 16 17 18 19 20 21 21 22 23 23 24 24 24 25 25 25 26 26 26 26 27 27 27 27 27 27 28
16 18 20 22 23 24 26 27 27 28 29 30 30 31 31 32 32 32 33 33 33 34 34 34 35 35 35 35 35
23 26 29 31 33 35 37 38 39 41 42 42 43 44 45 45 46 47 47 48 48 49 49 49 50 50 50 51 51
30 34 38 41 44 46 48 50 51 53 54 55 57 58 58 59 60 61 62 62 63 63 64 64 65 65 66 66 66
Cert. No.
762b/01
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting I section beams and H section columns at a critical temperature of 550ºC Product Name
Section Factor (Hp/A)
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 18
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 23
Cafco 300
40 50 60 70 80 90 100 110 120 130 140 150
12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 13 13 14 14 14 15 15
12 13 14 16 17 18 18 19 20 20 21 21
15 17 19 20 21 23 24 25 25 26 27 27
21 24 27 29 31 33 34 35 37 38 39 40
28 32 35 38 41 43 45 46 48 49 51 52
20 Nov 2011
Cert. No.
762b/01
135
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 15 16 16 16 16 17 17 17 17 17 17 18 18 18 18 18 18
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 22 22 22 23 23 23 24 24 24 24 25 25 25 25 25 25 26
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 28 28 29 29 30 30 30 31 31 31 32 32 32 32 33 33 33
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 40 41 42 42 43 44 44 45 45 45 46 46 46 47 47 47 48
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 53 54 55 56 56 57 58 58 59 59 60 60 61 61 62 62 62
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting I section beams and H section columns at a critical temperature of 600ºC Product Name
Section Factor (Hp/A)
Cafco 300
136
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 minn 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 17
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 22
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 12 12 13 13 13 14 14 14 14 15 15 15 15 15 15 16 16 16 16 16 16 16
12 12 13 14 15 16 17 18 18 19 19 19 20 20 21 21 21 21 22 22 22 22 22 23 23 23 23 23
14 16 17 19 20 21 22 23 23 24 25 25 26 26 27 27 27 28 28 28 29 29 29 29 29 30 30 30
20 23 25 27 29 31 32 33 34 35 36 37 38 38 39 39 40 40 41 41 42 42 42 43 43 43 44 44
26 30 33 36 38 40 42 44 45 46 47 48 49 50 51 52 52 53 54 54 55 55 56 56 57 57 57 58
Cert. No.
762b/01
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
320
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 minn 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 16
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 23
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 44
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 58
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting I section beams and H section columns at a critical temperature of 620ºC Product Name
Section Factor (Hp/A)
Cafco 300
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 16
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 20
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 12 12 12 13 13 13 13 14 14 14 14 14 15 15 15 15 15 15 15 16 16 16 16
12 12 13 14 15 15 16 17 17 18 18 19 19 19 20 20 20 21 21 21 21 21 22 22 22 22 22 22 23
13 15 16 18 19 20 21 22 23 23 24 24 25 25 26 26 26 27 27 27 28 28 28 28 29 29 29 29 29
19 22 24 26 28 29 31 32 33 34 35 35 36 37 37 38 39 39 39 40 40 41 41 41 42 42 42 43 43
25 28 31 34 36 38 40 42 43 44 46 47 48 48 49 50 51 51 52 52 53 53 54 54 55 55 56 56 56
Cert. No.
762b/01
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
20 Nov 2011
137
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Cafco 300, required thickness when protecting I section beams and H section columns at a critical temperature of 650ºC Product Name
Section Factor (Hp/A)
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 15
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 20
Cafco 300
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 13 14 14 14 14 14 14 14 14 14 15 15 15
12 12 12 13 14 15 15 16 16 17 17 18 18 18 19 19 19 20 20 20 20 20 20 21 21 21 21 21 21
13 14 16 17 18 19 20 21 22 22 23 23 24 24 24 25 25 25 26 26 26 27 27 27 27 27 28 28 28
18 21 23 25 27 28 29 31 32 33 33 34 35 35 36 37 37 37 38 38 39 39 39 40 40 40 40 41 41
24 28 31 33 35 37 39 40 42 43 44 45 46 47 47 48 49 49 50 51 51 51 52 52 53 53 53 54 54
Cert. No.
762b/01
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting I section beams and H section columns at a critical temperature of 700ºC Product Name
Section Factor (Hp/A)
Cafco 300
138
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 13
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 18
40 50 60 70 80 90 100 110 120 130 140 150
12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 13 14 14 15 15 15
12 12 14 15 16 17 18 18 19 20 20 21
16 19 21 23 24 26 27 28 29 30 31 32
22 25 28 31 33 35 36 38 39 41 42 43
Cert. No.
762b/01
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 16 16 16 17 17 17 17 17 18 18 18 18 18 18 18 19 19
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 21 22 22 22 23 23 23 24 24 24 24 25 25 25 25 25 26
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 33 33 34 34 35 35 36 36 37 37 37 38 38 38 39 39 39
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 44 45 45 46 47 48 48 49 49 50 50 51 51 51 52 52 53
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature of 350ºC Product Name
Section Factor (Hp/A)
Cafco 300
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 15
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 19
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 28
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 36
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
12 12 12 12 12 12 12 12 13 13 14 14 14 15 15 15 16 16 16 17 17 17 17 17 18 18 18 18
13 14 16 17 18 19 20 21 22 23 24 24 25 25 26 27 27 28 28 29 29 30 30 30 30 30 31 31
18 20 22 24 26 28 29 30 31 32 33 34 35 36 37 38 39 39 40 41 41 42 42 43 43 43 43 44
23 26 29 32 34 36 37 39 41 42 43 45 46 47 48 49 50 51 52 53 54 54 55 55 55 56 56 56
33 38 42 46 49 52 54 57 59 61 63 65 66 68 70 71 -
44 50 55 60 64 68 71 -
20 Nov 2011
Cert. No.
762b/01
139
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature of 400ºC Product Name
Section Factor (Hp/A)
Cafco 300
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 13
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 16
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 23
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 30
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
12 12 12 12 12 12 12 12 13 13 14 14 15 15 15 16 16 16 17 17 17 17 18 18 18 18 18 18
12 13 15 16 17 18 19 20 20 21 22 23 23 24 24 25 25 26 26 27 27 28 28 28 28 29 29 29
16 18 20 22 23 24 26 27 28 29 30 31 32 33 33 34 35 35 36 37 37 38 38 39 39 39 39 40
20 23 25 27 29 31 33 34 36 37 38 39 40 41 42 43 44 45 46 47 48 48 49 49 49 50 50 50
28 32 36 39 42 44 47 49 51 53 54 56 57 59 60 62 63 64 65 67 68 69 69 70 70 71 71 72
36 42 46 50 54 57 60 63 66 68 70 -
Cert. No.
762b/01
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature 450ºC Product Name
Section Factor (Hp/A)
Cafco 300
140
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 15
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 21
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 28
40 50 60 70 80 90 100
12 12 12 12 12 12 12
12 12 13 15 16 17 17
14 17 18 20 21 23 24
18 21 23 25 27 29 31
26 30 33 36 39 41 44
34 39 43 47 51 54 57
Cert. No.
762b/01
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12 12 12 13 13 13 14 14 14 15 15 15 15 16 16 16 16 16 16 17 17
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 18 19 20 20 21 21 22 23 23 24 24 24 25 25 26 26 26 26 26 27 27
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 25 26 27 28 29 30 30 31 32 32 33 34 34 35 35 36 36 36 37 37 37
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 32 33 34 36 37 38 39 40 40 41 42 43 44 45 45 46 46 46 47 47 47
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 46 48 49 51 52 54 55 57 58 59 60 61 63 64 65 65 66 66 67 67 67
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 59 62 64 66 68 70 72 -
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature of 500ºC Product Name
Section Factor (Hp/A)
Cafco 300
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 14
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 20
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 25
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270
12 12 12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 14 14 14 14 14 15
12 12 12 13 14 15 16 17 17 18 18 19 20 20 21 21 21 22 22 23 23 24 24 24
13 15 17 18 20 21 22 23 24 25 26 26 27 28 29 29 30 31 31 32 32 33 33 33
17 19 21 23 25 27 28 29 31 32 33 34 35 36 37 38 38 39 40 41 41 42 42 43
24 27 31 33 36 38 40 42 44 46 47 49 50 52 53 54 55 56 57 59 60 61 61 62
31 36 40 44 47 50 53 55 58 60 62 64 65 67 69 71 72 -
20 Nov 2011
Cert. No.
762b/01
141
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
280 290 300 310
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 15 15 15 15
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 24 24 24 25
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 34 34 34 34
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 43 43 44 44
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 62 62 63 63
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min -
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature of 550ºC Product Name
Section Factor (HP/A)
Cafco 300
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 13
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 18
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 24
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 13 13 13 13
12 12 12 12 13 14 14 15 16 16 17 17 18 18 19 19 20 20 20 21 21 22 22 22 22 22 22 22
12 14 15 17 18 19 20 21 22 23 24 24 25 26 26 27 28 28 29 29 30 30 31 31 31 31 31 32
15 18 20 22 23 25 26 27 28 29 30 31 32 33 34 35 36 36 37 38 38 39 39 40 40 40 41 41
22 25 28 31 33 36 38 39 41 43 44 45 47 48 49 50 52 53 54 55 56 57 57 58 58 58 59 59
29 33 37 41 44 47 49 51 54 56 58 60 61 63 64 66 67 69 70 72 -
Cert. No.
762b/01
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
142
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature of 600ºC Product Name
Section Factor (Hp/A)
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 17
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 22
Cafco 300
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 13 14 14 15 15 16 16 17 17 17 18 18 18 19 19 19 20 20 20 20 20 20
12 13 14 15 17 18 19 19 20 21 22 22 23 24 24 25 25 26 26 27 27 28 28 28 28 28 29 29
14 17 18 20 22 23 24 25 26 27 28 29 30 31 31 32 33 33 34 35 35 36 36 36 37 37 37 37
21 24 27 29 31 33 35 37 38 40 41 42 44 45 46 47 48 49 50 51 52 52 53 53 54 54 54 55
27 31 35 38 41 44 46 48 50 52 54 56 57 59 60 62 63 64 65 67 68 69 70 70 71 71 72 72
Cert. No.
762b/01
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature of 620ºC Product Name
Section Factor (Hp/A)
Cafco 300
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 16
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 21
40 50 60 70 80 90 100 110 120 130 140 150 160
12 12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 12 13 14 14 15 15 16
12 12 13 15 16 17 18 19 19 20 21 21 22
14 16 17 19 21 22 23 24 25 26 27 28 29
20 23 25 28 30 32 34 35 37 38 39 41 42
26 30 33 36 39 42 44 46 48 50 52 54 55
20 Nov 2011
Cert. No.
762b/01
143
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 16 16 17 17 17 18 18 18 19 19 19 19 19 19 20
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 23 23 24 24 25 25 26 26 27 27 27 27 28 28 28
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 29 30 31 32 32 33 34 34 35 35 35 36 36 36 36
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 43 44 45 46 47 48 49 50 51 51 52 52 52 53 53
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 57 58 59 61 62 63 64 66 67 67 68 68 69 69 70
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature of 650ºC Product Name
Section Factor (Hp/A)
Cafco 300
144
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 16
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 21
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 12 12 13 13 14 14 15 15 15 16 16 16 17 17 17 17 18 18 18 18 18 18
12 12 13 14 15 16 17 18 18 19 20 20 21 22 22 23 23 24 24 24 25 25 25 26 26 26 26 26
13 15 17 18 20 21 22 23 24 25 26 27 27 28 29 29 30 31 31 32 33 33 33 34 34 34 34 35
19 22 25 27 29 31 32 34 35 37 38 39 40 41 42 43 44 45 46 47 48 49 49 49 50 50 50 51
25 29 32 35 38 40 43 45 47 48 50 52 53 55 56 57 59 60 61 62 63 64 65 65 66 66 67 67
Cert. No.
762b/01
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco 300, required thickness when protecting hollow section beams and columns at a critical temperature of 700ºC Product Name
Section Factor (Hp/A)
Cafco 300
30
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 30 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 60 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 120 min 12
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 180 min 14
Applied Thickness (mm) of Cafco 300 for Fire Resistance Protection Periods of; 240 min 19
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 13 13 13 13 14 14 14 14 14 14 15 15 15
12 12 12 12 13 14 14 15 16 16 17 18 18 19 19 20 20 20 21 21 22 22 22 22 23 23 23 23
12 13 15 16 17 18 19 20 21 22 23 24 25 25 26 27 27 28 28 29 30 30 30 31 31 31 31 32
17 20 22 24 26 28 30 31 33 34 35 37 38 39 40 41 42 43 44 44 45 46 47 47 47 48 48 48
23 27 30 33 35 38 40 42 44 46 48 49 51 52 54 55 56 57 59 60 61 62 63 63 64 64 65 65
Cert. No.
762b/01
Notes: 1. LPCB Ref 726b/01 - approval for Cafco 300 without accelerator, profile application applied in several coats dependant on thickness. 2. LPCB Ref 726b/01 - Cafco 300 approved from the following manufacturing sites only; Promat UK Ltd, Lawn Road Industrial Estate, Carlton-in-Lindrick, Worksop, Notts S81 9LB UK and Cafco International LLC, Sharjah, UAE.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 350ºC Product Name
Section Factor (Hp/A)
Cafco Mandolite CP2
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 13
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 17
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 22
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 31
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 40
40 50
10 10
15 16
20 21
25 27
35 38
45 49
20 Nov 2011
Cert. No.
762b/02
145
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 11 12 12 12 13 13 13 13 13 14 14 14 14 14 14 14 14 14 14 14 14 15 15 15 15 15
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 17 18 18 19 19 20 20 20 21 21 21 21 21 21 22 22 22 22 22 22 22 22 22 22 22 23
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 23 24 25 25 26 26 27 27 28 28 28 28 29 29 29 29 29 30 30 30 30 30 30 30 30 30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 29 30 31 32 33 33 34 34 35 35 35 36 36 36 37 37 37 37 37 37 38 38 38 38 38 38
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 40 42 44 45 46 47 48 48 49 50 50 50 51 51 52 52 52 52 53 53 53 53 53 53 54 54
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 52 54 56 58 59 61 62 62 63 64 65 65 66 66 66 67 67 68 68 68 68 69 69 69 69 69
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 400ºC Product Name
Section Factor (Hp/A)
Cafco Mandolite CP2
146
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 11
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 15
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 19
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 27
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 35
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190
8 9 10 10 11 11 11 12 12 12 12 12 13 13 13 13
13 14 15 16 17 17 18 18 18 19 19 19 19 20 20 20
17 19 20 22 22 23 24 24 25 25 26 26 26 27 27 27
22 24 26 27 28 29 30 31 31 32 32 33 33 34 34 34
31 34 37 38 40 41 43 44 44 45 46 46 47 47 48 48
40 44 47 50 52 54 55 56 57 58 59 60 61 61 62 62
Cert. No.
762b/02
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
200 210 220 230 240 250 260 270 280 290 300 310
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 13 13 13 13 13 13 13 13 14 14 14 14
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 20 20 20 20 21 21 21 21 21 21 21 21
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 27 27 28 28 28 28 28 28 28 29 29 29
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 34 35 35 35 35 35 36 36 36 36 36 36
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 49 49 49 50 50 50 50 51 51 51 51 51
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 63 63 64 64 64 65 65 65 66 66 66 66
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 450ºC Product Name
Section Factor (Hp/A)
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 10
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 13
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 17
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 24
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 31
Cafco Mandolite CP2
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
8 8 9 9 10 10 10 10 11 11 11 11 11 12 12 12 12 12 12 12 12 12 12 12 12 13 13 13
11 13 14 14 15 16 16 16 17 17 17 18 18 18 18 19 19 19 19 19 19 19 19 20 20 20 20 20
15 17 18 20 20 21 22 22 23 23 24 24 25 25 25 25 26 26 26 26 26 26 27 27 27 27 27 27
20 22 23 25 26 27 28 29 29 30 30 31 31 31 32 32 32 33 33 33 33 33 34 34 34 34 34 34
28 31 33 35 37 38 40 41 41 42 43 44 44 45 45 46 46 46 47 47 47 48 48 48 48 49 49 49
36 40 43 46 48 50 51 53 54 55 56 57 57 58 59 59 60 60 61 61 61 62 62 62 63 63 53 63
20 Nov 2011
Cert. No.
762b/02
147
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 500ºC Product Name
Section Factor (Hp/A)
Cafco Mandolite CP2
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 12
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 15
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 21
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 27
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
8 8 8 8 8 9 9 9 10 10 10 10 10 10 11 11 11 11 11 11 11 11 11 11 11 11 12 12
10 11 12 13 14 14 15 15 15 16 16 16 17 17 17 17 17 17 18 18 18 18 18 18 18 18 18 19
14 15 17 18 19 19 20 21 21 22 22 22 23 23 23 24 24 24 24 24 25 25 25 25 25 25 25 26
17 19 21 23 24 25 26 26 27 28 28 29 29 29 30 30 30 31 31 31 31 32 32 32 32 32 32 32
25 28 30 32 34 35 37 38 39 39 40 41 41 42 42 43 43 44 44 44 45 45 45 46 46 46 46 46
32 36 39 42 44 46 47 49 50 51 52 53 54 55 55 56 56 57 57 58 58 59 59 59 60 60 60 60
Cert. No.
762b/02
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 550ºC Product Name
Section Factor (Hp/A)
Cafco Mandolite CP2
148
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 10
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 13
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 18
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 24
40 50 60 70 80
8 8 8 8 8
9 10 11 11 12
12 14 15 16 17
15 17 19 20 21
22 25 27 29 31
29 32 36 38 40
Cert. No.
762b/02
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8 8 8 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10 10 10 10 11
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 13 13 14 14 14 15 15 15 15 16 16 16 16 16 16 17 17 17 17 17 17 17 17
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 18 18 19 19 20 20 21 21 21 22 22 22 22 23 23 23 23 23 23 24 24 24 24
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 23 23 24 25 25 26 26 27 27 28 28 28 29 29 29 29 30 30 30 30 30 31 31
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 32 34 35 36 37 37 38 39 39 40 40 41 41 42 42 42 43 43 43 43 44 44 44
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 42 44 45 47 48 49 50 51 51 52 53 53 54 54 55 55 56 56 56 57 57 57 58
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 600ºC Product Name
Section Factor (Hp/A)
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 9
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 11
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 16
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 21
Cafco Mandolite CP2
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220
8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9
8 8 9 10 11 11 12 12 12 13 13 13 14 14 14 14 14 15 15
10 12 13 14 15 16 16 17 18 18 18 19 19 20 20 20 20 21 21
13 15 17 18 19 20 21 22 23 23 24 24 25 25 26 26 26 27 27
20 22 24 26 28 30 31 32 33 34 35 35 36 37 37 38 38 39 39
26 29 32 35 37 39 40 42 43 44 45 46 47 48 49 49 50 50 51
20 Nov 2011
Cert. No.
762b/02
149
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
230 240 250 260 270 280 290 300 310
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 9 9 9 9 9 9 9 9 9
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 15 15 15 15 15 16 16 16 16
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 21 21 21 22 22 22 22 22 22
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 27 27 28 28 28 28 28 29 29
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 39 40 40 40 41 41 41 41 42
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 52 52 52 53 53 54 54 54 55
Cert. No.
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 620ºC Product Name
Section Factor (Hp/A)
Cafco Mandolite CP2
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 11
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 15
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 20
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 9 9 9
8 8 9 10 10 11 11 12 12 12 13 13 13 13 14 14 14 14 14 14 15 15 15 15 15 15 15 15
10 11 12 13 14 15 16 16 17 17 18 18 19 19 19 19 20 20 20 20 21 21 21 21 21 21 21 22
13 15 16 17 19 20 20 21 22 22 23 24 24 24 25 25 25 26 26 26 27 27 27 27 27 28 28 28
19 21 23 25 27 28 30 31 32 33 33 34 35 35 36 37 37 37 38 38 39 39 39 40 40 40 40 41
24 28 31 33 35 37 39 40 42 43 44 45 46 46 47 48 49 49 50 50 51 51 51 52 52 53 53 53
Cert. No.
762b/02
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
150
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 650ºC Product Name
Section Factor (Hp/A)
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 9
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 10
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 14
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 19
Cafco Mandolite CP2
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
8 8 8 9 9 10 10 11 11 11 12 12 12 12 13 13 13 13 13 13 13 14 14 14 14 14 14 14
9 10 11 12 13 14 15 15 16 16 17 17 17 18 18 18 18 19 19 19 19 19 20 20 20 20 20 20
12 13 15 16 17 18 19 20 20 21 22 22 23 23 23 24 24 24 25 25 25 25 26 26 26 26 26 27
17 20 22 24 25 27 28 29 30 31 32 32 33 34 34 35 35 36 36 36 37 37 37 38 38 38 39 39
23 26 29 31 33 35 37 38 39 41 42 43 43 44 45 46 46 47 47 48 48 49 49 50 50 50 51 51
Cert. No.
762b/02
Certificate No: 762b to LPS 1107: Issue 1 - BS 476: Part 21: 1987
Cafco Mandolite CP2, required thickness when protecting I section beams and H section columns at a critical temperature of 700ºC Product Name
Section Factor (Hp/A)
Cafco Mandolite CP2
30
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 12
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 16
40 50 60 70 80 90 100 110 120
8 8 8 8 8 8 8 8 8
8 8 8 8 8 8 9 9 9
8 9 10 11 12 12 13 13 14
10 12 13 14 15 16 17 18 18
15 17 19 21 23 24 25 26 27
20 23 26 28 30 32 33 35 36
20 Nov 2011
Cert. No.
762b/02
151
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Section Factor (Hp/A)
130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 30 min 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 60 min 10 10 10 10 11 11 11 11 11 12 12 12 12 12 12 12 12 12 12
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 90 min 14 15 15 15 16 16 16 16 17 17 17 17 17 18 18 18 18 18 18
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 120 min 19 19 20 20 21 21 21 22 22 22 23 23 23 23 23 24 24 24 24
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 180 min 28 29 29 30 31 31 32 32 33 33 34 34 34 35 35 35 35 36 36
Applied Thickness (mm) of Cafco Mandolite CP2 for Fire Resistance Protection Periods of; 240 min 37 38 39 40 41 41 42 43 43 44 44 45 45 46 46 47 47 47 48
Cert. No.
Notes: 1. LPCB Ref 726b/02 - profile application applied in several coats dependant on thickness. 2. LPCB Ref 726b/02 - applied thicknesses quoted are without re-enforcement mesh included in coating. 3. LPCB Ref 726b/02 - Cafco Mandolite CP2 approved from the following manufacturing site only; Promat UK Ltd, Lawn Road Industrial Estate, Carlton-in-Lindrick, Worksop, Notts S81 9LB UK.
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022d to LPS 1107: Issue 1 Product Name
Exposure
Additional Information
Rockwool FirePro(TM) BeamClad systems
Internal and semi exposed
Thickness range 25mm to 110mm. Fire resistance 30-240min (see tables below). Faced and unfaced boards are available, refer to manufacturer's technical literature for fixing details.
Cert. No. 022d/01
3 Sided Protection of Steel Beams, Supporting Concrete/Composite Decks Using The Clip Fix Or Stud Welded Pins/Dry Joint System (critical failure temperature 620°C) Product Name BeamClad
152
Board Thickness (mm) 25 30 35 40 45 50 55 60
Performance Hp/A 30min
Performance Hp/A 60min
Performance Hp/A 90min
Performance Hp/A 120min
Cert. No.
260 260 260 260 260 260 260 260
260 260 260 260 260 260 260 260
260 260 260 260 260 260 260 260
95 124 159 200 251 260 260 260
022d/01
20 Nov 2011
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS
3 Sided Protection Of Steel Beams, Supporting Concrete/Composite Decks Using The Bonded Noggin/Dry Joint System (critical failure temperature 620°C) Product Name BeamClad
Board Thickness (mm) 25 30 35 40 45 50 55 60
Performance Hp/A 30min
Performance Hp/A 60min
Performance Hp/A 90min
Performance Hp/A 120min
Cert. No.
260 260 260 260 260 260 260 260
260 260 260 260 260 260 260 260
196 260 260 260 260 260 260 260
73 93 116 143 173 209 252 260
022d/01
3 Sided Protection Of Steel Beams, Supporting Concrete/Composite Decks Using The Bonded Noggin Or Stud Welded Pins/Glued Joint System (critical failure temperature 620°C) Product Name BeamClad
Board Thickness (mm) 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 110
Performance Hp/A 30min
Performance Hp/A 60min
Performance Hp/A 90min
Performance Hp/A 120min
Performance Hp/A 180min
Performance Hp/A 240min
Cert. No.
260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
168 235 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
52 65 80 95 113 132 154 178 206 237 260 260 260 260 260 260 260
45 53 62 70 80 90 100 112 124 136 150 165 181 199 238
022d/01
4 Sided Protection Of Steel Beams And Columns Using The Clip Fix Or Stud Welded Pins/Dry Joint System (critical failure temperature 550°C) Product Name BeamClad
Board Thickness (mm) 25 30 35 40 45 50 55 60
Performance Hp/A 30min
Performance Hp/A 60min
Performance Hp/A 90min
Performance Hp/A 120min
Cert. No.
260 260 260 260 260 260 260 260
260 260 260 260 260 260 260 260
148 260 260 260 260 260 260 260
65 84 104 128 155 187 225 260
022d/01
4 Sided Protection Of Steel Beams And Columns Using The Bonded Noggin/Dry Joint System (critical failure temperature 550°C) Product Name BeamClad
20 Nov 2011
Board Thickness (mm) 25 30 35 40 45 50 55
Performance Hp/A 30min 260 260 260 260 260 260 260
Performance Hp/A 60min 260 260 260 260 260 260 260
Performance Hp/A 90min 146 202 260 260 260 260 260
Performance Hp/A 120min 65 83 103 126 153 184 221
Cert. No. 022d/01
153
PART 1: SECTION 4.1 LPS 1107 STRUCTURAL STEEL FIRE PROTECTION - BOARD AND CEMENTITIOUS COVERINGS Product Name
Board Thickness (mm) 60
Performance Hp/A 30min 260
Performance Hp/A 60min 260
Performance Hp/A 90min 260
Performance Hp/A 120min 260
Cert. No.
4 Sided Protection Of Steel Columns Using The Bonded Noggin Or Stud Welded Pins/Glued Joint System (critical failure temperature 550°C) Product Name BeamClad
Board Thickness (mm) 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 110
Performance Hp/A 30min 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
Performance Hp/A 60min 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
Performance Hp/A 90min 149 207 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
Performance Hp/A 120min 65 83 104 128 155 187 225 260 260 260 260 260 260 260 260 260 260
Performance Hp/A 180min 45 54 62 72 82 92 104 116 129 143 159 176 194 214 260
Performance Hp/A 240min 44 50 55 61 68 74 81 88 96 103 124 129
Cert. No. 022d/01
4 Sided Protection Of Steel Beams Using The Bonded Noggin Or Stud Welded Pins/Glued Joint System (critical failure temperature 550°C) Product Name BeamClad
154
Board Thickness (mm) 25 30 35 40 45 50 55 65 65 70 75 80 85 90 95 100 110
Performance Hp/A 30min 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
Performance Hp/A 60min 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
Performance Hp/A 90min 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260
Performance Hp/A 120min 98 130 168 216 260 260 260 260 260 260 260 260 260 260 260 260 260
Performance Hp/A 180min 40 50 61 73 85 99 114 131 150 170 193 219 248 260 260 260 260
Performance Hp/A 240min 43 50 57 65 73 81 90 99 109 120 131 144 157 186
Cert. No. 022d/01
20 Nov 2011
PART 1: SECTION 4.2 STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS
The protection of the structural integrity of a building is important for life safety of the occupants, fire fighters and for the cost-effective repair of the building post fire. When a building is involved in a fire, structural steelwork can resist the damaging effects of the high temperatures generated if suitably protected. This section covers structural steel fire protection with use of intumescent thin film coatings approved to SD075 Fire Protection for Structural Steelwork (Intumescent Systems) (BS 476: Parts 20 & 21).
Promat UK Ltd The Sterling Centre, Eastern Road, Bracknell, Berkshire RG12 2TD, United Kingdom Tel: +44 (0)1344 381 300 • Fax: +44 (0)1344 381 301 Website: www.promat-spray.co.uk Certificate No: 762a to SD075 - BS 476: Parts 20 & 21
Cafco Sprayfilm WB3 Intumescent Paint, 4 Sided Protection on Hollow Sections 532ºC Product Name
Section Factor (Hp/A)
Up to 45
Intumescent Dry Film Thickness (mm) for Protection Periods of: 30 min 0.61
Intumescent Dry Film Thickness (mm) for Protection Periods of: 60 min 0.61
Intumescent Dry Film Thickness (mm) for Protection Periods of: 90 min 1.80
Intumescent Dry Film Thickness (mm) for Protection Periods of: 120 min 3.51
SprayFilm WB3
45-50 51-55 56-60 61-65 66-70 71-75 76-80 81-85 86-90 91-95 96-100 101-105 106-110 111-115 116-120 121-125 126-130 131-135 136-140 141-145 146-150 151-155 156-160 161-165 166-170 171-175 176-180 181-185 186-190 191-195 196-200 201-205 206-210 211-215 216-220 221-225 226-230 231-235 236-240 241-245 246-250
0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61
0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.69 0.78 0.86 0.94 1.06 1.08 1.11 1.14 1.17 1.20 1.23 1.26 1.29 1.32 1.35 1.38 1.41 1.45 1.48 1.51 1.54 1.57 1.60 1.63 1.66 1.69 1.72 1.75 1.78 1.83 1.91 1.99
1.80 1.80 1.80 1.90 2.00 2.10 2.19 2.29 2.39 2.49 2.55 2.62 2.67 2.72 2.77 2.83 2.88 2.93 2.98 3.03 3.08 3.13 3.18 3.25 3.29 3.34 3.39 3.44 3.51 3.61 3.77 3.93 4.08 4.24 4.40 4.56 4.72 4.88 5.04 5.20 5.36
3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.59 3.99 4.39 4.80 5.20 5.60 6.00 -
20 Nov 2011
Cert. No.
762a/01
155
PART 1: SECTION 4.2 STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS Product Name
Section Factor (Hp/A)
251-255 256-260 261-265 266-270 271-275 276-280 281-285 286-290 291-295 296-300 301-305 306-310 311-315 316-320
Intumescent Dry Film Thickness (mm) for Protection Periods of: 30 min 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61
Intumescent Dry Film Thickness (mm) for Protection Periods of: 60 min 2.07 2.15 2.23 2.31 2.39 2.47 2.55 2.62 2.68 2.75 2.82 2.88 2.95 3.02
Intumescent Dry Film Thickness (mm) for Protection Periods of: 90 min 5.52 5.68 5.84 6.00 -
Intumescent Dry Film Thickness (mm) for Protection Periods of: 120 min -
Cert. No.
Notes: 1. LPCB Ref 762a/01 - Intumescent dry film thickness excludes any primer or top coat film thickness. 2. LPCB Ref 762a/01 - SprayFilm WB3 approved from the following manufacturing sites; Promat UK Ltd, Lawn Road Industrial Estate, Carlton-in-Lindrick, Worksop, Notts S81 9LB UK and Comais Srl, Via Provinciale, 10 - Filago (BG), 24040 Italy (FPC Ref. 935). Certificate No: 762a to SD075 - BS 476: Parts 20 & 21
Cafco Sprayfilm WB3 Intumescent Paint, 3 Sided Protection On I Section Beams (continuous concrete topping) 620ºC Product Name
Section Factor (Hp/A)
SprayFilm WB3
156
Up to 45
Intumescent Dry Film Thickness (mm) for Protection Periods of: 30 min 0.23
Intumescent Dry Film Thickness (mm) for Protection Periods of: 60 min 0.25
Intumescent Dry Film Thickness (mm) for Protection Periods of: 90 min 1.20
Intumescent Dry Film Thickness (mm) for Protection Periods of: 120 min 1.20
45-50 51-55 56-60 61-65 66-70 71-75 76-80 81-85 86-90 91-95 96-100 101-105 106-110 111-115 116-120 121-125 126-130 131-135 136-140 141-145 146-150 151-155 156-160 161-165 166-170 171-175 176-180 181-185 186-190 191-195 196-200 201-205
0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23
0.25 0.25 0.25 0.25 0.25 0.25 0.27 0.28 0.30 0.32 0.34 0.36 0.38 0.40 0.42 0.44 0.46 0.48 0.50 0.52 0.54 0.56 0.57 0.57 0.57 0.61 0.64 0.67 0.70 0.73 0.76 0.80
1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.22 1.25 1.28 1.31 1.34 1.37 1.40 1.43 1.46 1.49 1.54 1.60 1.66 1.72 1.78 1.84 1.90
1.20 1.20 1.20 1.20 1.23 1.28 1.33 1.39 1.44 1.49 1.63 1.78 1.94 2.04 2.10 2.17 2.23 2.30 2.36 2.43 2.49 2.56 2.62 2.69 2.75 2.82 2.88 2.95 3.01 3.18 3.33 3.48
Cert. No.
762a/01
20 Nov 2011
PART 1: SECTION 4.2 STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS Product Name
Section Factor (Hp/A)
206-210 211-215 216-220 221-225 226-230 231-235 236-240 241-245 246-250 251-255 256-260 261-265 266-270 271-275 276-280 281-285 286-290 291-295 296-300 301-305 306-310 311-315 316-320
Intumescent Dry Film Thickness (mm) for Protection Periods of: 30 min 0.23 0.24 0.24 0.24 0.24 0.24 0.25 0.25 0.25 0.25 0.25 0.26 0.26 0.27 0.28 0.28 0.29 0.29 0.30 0.30 0.31 0.31 0.31
Intumescent Dry Film Thickness (mm) for Protection Periods of: 60 min 0.83 0.86 0.88 0.89 0.91 0.93 0.94 0.96 0.97 0.99 1.00 1.02 1.04 1.05 1.07 1.08 1.10 1.11 1.13 1.14 1.16 1.18 1.19
Intumescent Dry Film Thickness (mm) for Protection Periods of: 90 min 1.96 2.02 2.07 2.12 2.17 2.22 2.27 2.32 2.37 2.42 2.47 2.52 2.57 2.62 2.67 2.72 2.77 2.82 2.87 2.92 2.97 3.02 3.22
Intumescent Dry Film Thickness (mm) for Protection Periods of: 120 min 3.64 3.79 3.94 4.21 4.57 4.93 5.29 5.64 6.00 -
Cert. No.
Certificate No: 762a to SD075 - BS 476: Parts 20 & 21
Cafco Sprayfilm WB3 Intumescent Paint, 4 Sided Protection On I Section Beams 550ºC Product Name
Section Factor (Hp/A)
SprayFilm WB3
Up to 45
Intumescent Dry Film Thickness (mm) for Protection Periods of: 30 min 0.23
Intumescent Dry Film Thickness (mm) for Protection Periods of: 60 min 0.57
Intumescent Dry Film Thickness (mm) for Protection Periods of: 90 min 1.20
Intumescent Dry Film Thickness (mm) for Protection Periods of: 120 min 1.20
45-50 51-55 56-60 61-65 66-70 71-75 76-80 81-85 86-90 91-95 96-100 101-105 106-110 111-115 116-120 121-125 126-130 131-135 136-140 141-145 146-150 151-155 156-160 161-165 166-170 171-175 176-180 181-185 186-190 191-195
0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.24 0.24 0.24 0.24 0.24
0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.57 0.63 0.68 0.74 0.79 0.85 0.88 0.90 0.92 0.94 0.96 0.98 1.00 1.02 1.04
1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.25 1.30 1.35 1.40 1.45 1.50 1.60 1.69 1.79 1.88 1.98 2.04 2.08 2.13 2.18 2.22 2.27 2.32 2.36
1.25 1.31 1.38 1.46 1.53 1.75 1.93 2.05 2.13 2.21 2.29 2.37 2.44 2.52 2.60 2.68 2.76 2.84 2.92 3.00 3.13 3.25 3.38 3.50 3.63 3.75 3.88 4.00 4.31 4.63
20 Nov 2011
Cert. No.
762a/01
157
PART 1: SECTION 4.2 STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS Product Name
Section Factor (Hp/A)
196-200 201-205 206-210 211-215 216-220 221-225 226-230 231-235 236-240 241-245 246-250 251-255 256-260 261-265 266-270 271-275 276-280 281-285 286-290 291-295 296-300 301-305 306-310 311-315 316-320
Intumescent Dry Film Thickness (mm) for Protection Periods of: 30 min 0.25 0.25 0.25 0.25 0.26 0.27 0.27 0.28 0.29 0.30 0.30 0.31 0.32 0.32 0.33 0.34 0.35 0.35 0.36 0.37 0.38 0.38 0.39 0.40 0.40
Intumescent Dry Film Thickness (mm) for Protection Periods of: 60 min 1.05 1.07 1.09 1.11 1.13 1.15 1.17 1.19 1.21 1.23 1.25 1.27 1.29 1.31 1.33 1.35 1.37 1.39 1.41 1.43 1.45 1.47 1.49 1.51 1.54
Intumescent Dry Film Thickness (mm) for Protection Periods of: 90 min 2.41 2.46 2.50 2.55 2.60 2.64 2.69 2.74 2.79 2.83 2.88 2.93 2.97 3.02 3.23 3.39 3.55 3.71 3.87 4.03 4.31 4.56 4.82 5.08 5.33
Intumescent Dry Film Thickness (mm) for Protection Periods of: 120 min 4.94 5.25 5.56 5.88 6.19 -
Cert. No.
Certificate No: 762a/01 to SD075 - BS 476: Parts 20 & 21
Cafco Sprayfilm WB3 Intumescent Paint, 4 Sided Protection On I Section Columns 550ºC Product Name
Section Factor (Hp/A)
SprayFilm WB3
158
Up to 45
Intumescent Dry Film Thickness (mm) for Protection Periods of: 30 min 0.23
Intumescent Dry Film Thickness (mm) for Protection Periods of: 60 min 0.60
Intumescent Dry Film Thickness (mm) for Protection Periods of: 90 min 1.50
Intumescent Dry Film Thickness (mm) for Protection Periods of: 120 min 1.50
45-50 51-55 56-60 61-65 66-70 71-75 76-80 81-85 86-90 91-95 96-100 101-105 106-110 111-115 116-120 121-125 126-130 131-135 136-140 141-145 146-150 151-155 156-160 161-165 166-170 171-175 176-180 181-185
0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.24 0.24 0.24 0.24 0.24 0.25
0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.66 0.71 0.75 0.80 0.85 0.87 0.88 0.89 0.90 0.90 0.91 0.92 0.92
1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.57 1.62 1.67 1.72 1.78 1.83 1.88 1.93 1.98 2.03 2.08 2.14 2.19
1.50 1.50 1.50 1.50 1.67 1.83 2.00 2.08 2.15 2.23 2.31 2.38 2.46 2.54 2.62 2.69 2.77 2.85 2.92 3.00 3.11 3.23 3.34 3.45 3.57 3.68 3.80 3.91
Cert. No.
762a/01
20 Nov 2011
PART 1: SECTION 4.2 STRUCTURAL STEEL FIRE PROTECTION - INTUMESCENT THIN FILM COATINGS Product Name
Section Factor (Hp/A)
186-190 191-195 196-200 201-205 206-210 211-215 216-220 221-225 226-230 231-235 236-240 241-245 246-250 251-255 256-260 261-265 266-270 271-275 276-280 281-285 286-290 291-295 296-300 301-305 306-310 311-315 316-320
Intumescent Dry Film Thickness (mm) for Protection Periods of: 30 min 0.25 0.25 0.25 0.25 0.26 0.26 0.27 0.27 0.28 0.28 0.29 0.29 0.30 0.30 0.31 0.31 0.32 0.32 0.33 0.33 0.34 0.34 0.35 0.35 0.36 0.36 0.37
Intumescent Dry Film Thickness (mm) for Protection Periods of: 60 min 0.93 0.94 0.95 0.95 0.96 0.97 0.97 0.98 0.99 1.00 1.00 1.04 1.06 1.09 1.12 1.14 1.17 1.19 1.22 1.25 1.27 1.30 1.33 1.35 1.38 1.41 1.43
Intumescent Dry Film Thickness (mm) for Protection Periods of: 90 min 2.24 2.29 2.34 2.40 2.45 2.50 2.55 2.60 2.66 2.71 2.76 2.81 2.86 2.92 2.97 3.02 3.14 3.24 3.34 3.44 3.54 3.64 3.74 3.84 3.94 4.04 4.32
Intumescent Dry Film Thickness (mm) for Protection Periods of: 120 min 4.02 4.43 4.79 5.14 5.50 5.86 6.21 -
Cert. No.
Note: Intumescent dry film thickness exclude any primer or top coat film thickness.
20 Nov 2011
159
PART 1: SECTION 5 PROTECTIVE COVERING MATERIALS & SCAFFOLD CLADDING
This section includes LPS 1207 Fire requirements for protective covering materials which are used during the construction of new buildings and renovation of existing buildings, and LPS 1215 Requirements for the LPCB Approval and Listing of Scaffold cladding materials.
160
20 Nov 2011
PART 1: SECTION 5.1 LPS 1207 PROTECTIVE COVERING MATERIALS
During the construction of new buildings and renovation of existing buildings, it is common to use sheeting made from plastic or similar materials to provide protection against the weather, dust and other materials produced by work in adjacent areas. If a material complies with LPS 1207 Fire requirements for protective covering materials it will not add significantly to the fire risk. This standard is referred to in The Joint Code of Practice on the Protection from Fire of Construction Sites & Buildings Undergoing Renovation, 7th Edition published by the FPA in association with RISC Authority
20 Nov 2011
161
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING
Bainbridge International Limited Unit 8, Flanders Park, Flanders Road, Hedge End, Southampton, Hampshire SO30 2FZ, United Kingdom Tel: 01489 776050 • Fax: 01489 776055 E-mail: [email protected] • Website: www.coverguard.com Certificate No: 1058a to LPS 1207 Issue 2 Product Name Wall cover guard (CG0636TF & CG06272TF) Floor cover guard (CG1036DP-CG4036DP) Scaffold cover guard (CG0872SC)
Thickness (mm) 0.15 ± 15% 0.25 - 1.0 ± 15% 0.2 ± 15%
Cert. No. 1058a/01 1058a/02 1058a/03
Weight (g/m²) 150 ± 10% 250 - 1000 ± 10% 286 ± 10%
Notes: 1. LPCB Ref 1058a/01 & 1058a/02 Wall and Floor cover guard is available in blue only and covers non printed material with a printed product marking bands as required by LPS1207 Issue 2 Clause 4 only. 2. LPCB Ref 1058a/03 Scaffold cover guard is available in white only and covers non printed material with a printed product marking band as required by LPS1207 Issue 2 Clause 4 only.
BPI Visqueen - Greenock 96 Port Glasgow Road, Greenock, Scotland PA15 2UL, United Kingdom Tel: +44 (0)1475 501100 • Fax: +44 (0)1475 743256 Website: www.bpipoly.com Certificate No: 521a to LPS 1207: Issue 2 Product Name Megafilm Flame Retardant Polythene Protection Films (Visqueen Megafilm) Visqueen Flame Retardant Polythene Protection Films (Portathene WRE50)
Thickness (mm) 0.065 to 0.5 0.03 to 0.5
Weight (g/m2 ) -
Cert. No. 521a/01 521a/02
Note: 1. LPCB Ref. No. 521a/01 - Megafilm products can be supplied in various flat and textured profiles, and is available in a variety of colours. Certificate No: 688a-x4 to LPS1207: Issue 2 Product Name Megaboard Twinwall Polyrpopylene Megaboard Recycled FR
Thickness (mm) 2.0 - 4.5mm 2.0
Weight (g/m2) 250 - 1000 250
Cert. No. 688a-x4/01 688a-x4/02
Notes: 1. LPCB Ref No. 688a-x4/01 is available in white only and covers printed and non printed material with a product marking band as required by LPS 1207: Issue 2 Clause 4. 2. LPCB Ref.No. 688a-x4/02 is available in black only and covers non printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4 only.
Britton Merlin Limited Brackenborough Road, Louth, Lincolnshire LN11 0AX, United Kingdom Tel: +44 (0)1507 617800 • Fax: +44 (0)1507 601681 E-mail: [email protected] Certificate No: 499a to LPS 1207: Issue 2.1
162
20 Nov 2011
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING Product Name Tuffreel Flame Retardant (G6) BS2. Merlin
Thickness (mm) 0.038 - 0.25 ± 20% 0.04 ± 20%
Weight (g/m2 ) 38 - 250 ± 10% 40 ± 10%
Cert. No. 499a/01 499a/02
Notes: 1. LPCB Ref No. 499/01 covers non-printed material with a printed product marking band as required by LPS 1207: issue 2 Clause 4 only. 2. LPCB Ref. No. 499a/02 covers printed and non-printed material as sepcified with printed product marking band as required by LPS 1207: Issue 2 Clause 4.
Core Industrial Plastics Limited Unit 12, A1 Ferrybridge Business Park, Fishergate, Knottingley, West Yorkshire WF11 8NA, United Kingdom Tel: +44 (0)1977 676072 • Fax: +44 (0)1977 676069 E-mail: [email protected] Certificate No: 803a to LPS 1207: Issue 2 Product Name Total Protection Board (Black) Total Protection Board (White)
Thickness (mm) 2.3 ± 0.5 2.3 ± 0.5
Weight (g/m2 200 - 800 200 - 800
Cert. No. 803a/02 803a/03
Note: 1. LPCB Ref. No. 803a/02 & 803a/03 covers printed and non printed materials with a printed product marking band as required by LPS 1207 Issue 2 clause 4.
Don & Low Ltd, Nonwovens Glamis Road, Forfar, Angus DD8 1EY, United Kingdom Tel: +44 (0)1307 452600 • Fax: +44 (0)1307 452635 E-mail: [email protected] • Website: www.donlow.com Certificate No: 726a to LPS 1207: Issue 2 Product Name Daltex Flame Retardant Spunbond (A100E5TFR)
Thickness (mm) 0.5 nominal
Weight (g/m2 ) 100 ±6%
Cert. No. 726a/01
DS SMITH CORREX (Trading as a division of DS Smith Plastics Limited) Madleaze Industrial Estate, Bristol Road, Gloucester GL1 5SG, United Kingdom Tel: +44 (0)1452 316500 • Fax: +44 (0)1452 300436 E-mail: [email protected] • Website: www.kaysersberg-plastics.com Certificate No: 227a to LPS 1207: Issue 2 Product Name Correx Twinwall (black) Correx Twinwall (coloured & translucent)
20 Nov 2011
Thickness (mm) 2.0 to 6.0 2.0 to 6.0
Weight (g/m2 ) 250 to 1500 250 to 1500
Cert. No. 227a/01 227a/02
163
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING
Envirowrap Solutions Limited Registered Office:, Strangford House, Church Road, Ashford, Kent TN23 3QR, United Kingdom Tel: +44 (0)1233 860080 • Fax: +44 (0)1233 860090 E-mail: [email protected] • Website: www.envirowrap.info Certificate No: 691a to LPS 1207: Issue 2
Envirowrap 250, 300, 350 & 400AFR-T D06-08 Product Name
Thickness (mm) 0.25 ± 5% 0.30 ± 5% 0.35 ± 5% 0.40 ± 5%
Envirowrap 250AFR-T D06-08 Envirowrap 300AFR-T D06-08 Envirowrap 350AFR-T D06-08 Envirowrap 400AFR-T D06-08
Weight (g/m2) 253 ± 5% 305 ± 5% 348 ± 5% 399 ± 5%
Cert. No. 691a/02
Note: 1. LPCB Ref No. 691a/02 is available in white/light cream only and covers non printed product material with a printed product marking band as required by LPS 1207 Issue 2 Clause 4.
Florprotec Limited Relay Park, Relay Drive, Tamworth B77 5PR, United Kingdom Tel: +44 (0)1827 831440 • Fax: +44 (0)1827 831441 E-mail: [email protected] • Website: www.floorprotection.co.uk Certificate No: 688a-x1 to LPS 1207: Issue 2.1 Product Name Florprotec T-Bord Florprotec Envirobord
Thickness (mm) 2.0 - 4.5 2.0
Weight (g/m2 250 - 1000 250
Cert. No. 688a-x1/01 688a-x1/02
Notes: 1. LPCB Ref No. 688a-x1/01 is available in white only and covers printed and non printed material with a product marking band as required by LPS 1207: Issue 2 Clause 4. 2. LPCB Ref No. 688a-x1/02 is availabe in black only and covers non printed material with a printed product marking band as required by LPS1207: Issue 2 Clause 4 only. Certificate No: 871a to LPS1207: Issue 2.1 Product Name
Thickness
CPP-FR
0.16 ± 10%
Weight (g/m²) 84 ± 5%
Cert. No. 871a/01
Notes 1. LPCB Ref. No. 871a/01 covers white base sheet material, with or without additional printed areas, with a printed product marking band as required by LPS 1207 Issue 2 clause 4. Certificate No: 1030a to LPS 1207: Issue 2.1 Product Name TACBAC FR
Thickness (mm) 0.065 nominal
Weight (g/m²) 83 ± 10%
Cert. No. 1030a/01
Notes 1. LPCB Ref. No. 1030a/01 covers white (natural) base film material, printed and non-printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4. 2. LPCB ref. No. 1030a/01 TACBAC FR is a self-adhesive film. 3. LPCB ref. No. 1030a/01 TACBAC FR the thickness quoted is the nominal film thickness and weight is quoted inclusive of the adhesive.
164
20 Nov 2011
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING
Gilray Plant Limited Cedar Depot, Church Manorway, Erith, Kent DA8 1DE, United Kingdom Tel: 01322 442006 • Fax: 01322 442009 E-mail: [email protected] • Website: www.gilray.co.uk Certificate No: 915a-x2 to LPS 1207 Issue 2.1 Product Name Fire-Retardant Multisheet 220 FR Fire-Retardant Multisheet 170 FR
Thickness (mm) 0.7 ± 5% 0.7 ± 5%
Weight (g/m2 220 +7/ - 5% 170 ± 10%
Cert. No. 915a-x2/01 915a-x2/02
Note: 1. LPCB Ref No. 915a-x2/01 and 915a-x2/02 are available in white only and covers non printed material with a printed product marking band as required by LPS 1207 Issue 2 Clause 4 only.
Goran Plastics Unit C, 5 Caxton Way, Watford Business Park, Watford, Herts WD18 8UA, United Kingdom Tel: +44 (0)1923 255700 • Fax: +44 (0)1923 255698 E-mail: [email protected] Certificate No: 688a to LPS 1207: Issue 2 Product Name Polyflute Twinwall Polypropylene Polyflute Recycled FR
Thickness (mm) 2.0 - 4.5 2.0
Weight (g/m2) 250 - 1000 250
Cert. No. 688a/01 688a/02
Notes: 1. LPCB Ref No. 688a/01 is available in white only and covers printed and non printed material with a product marking band as required by LPS 1207: Issue 2 Clause 4. 2. LPCB Ref. No. 688a/02 is available in black only and covers non printed material with a printed product making band as required by LPS 1207: Issue 2 Clause 4 only.
Icopal Limited Barton Dock Road, Stretford, Manchester M32 0YL, United Kingdom Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 865 8433 E-mail: [email protected] • Website: www.icopal.co.uk Certificate No: 572c to LPS 1207: Issue 2 Product Name Monarflex Stripe Firesmart Monarflex Super T Plus Firesmart
Thickness (mm) 0.15 Nominal 0.2 to 0.55
Weight (g/m2) 210 ± 5% 275 ± 5%
Cert. No. 540c/01 572c/01
Notes: 1. LPCB Ref. No. 572c/01 Monarflex Super T Plus Firesmart roll size 2.25m x 40m, 2m x 45m, 3m x 45m and 4m x 36m. Product produced at Monarflex s.r.o 2. LPCB Ref. No. 572c/01 covers printed and non printed materials with a printed product marking band as required by LPS1207: Issue 2 Clause 4. 3. LPCB Ref. No. 540c/01 is available in white only and covers non printed materials with a printed product marking band as required by LPS1207: Issue 2 Clause 4 only.
20 Nov 2011
165
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING
Industrial Textiles & Plastics Ltd Stillington Road, Easingwold, York YO61 3FA, United Kingdom Tel: +44 (0)1347 825200 • Fax: +44 (0)1347 825222 E-mail: [email protected] • Website: www.itpltd.com Certificate No: 727a to LPS 1207: Issue 2
Powerclad Product Name Powerclad SDFR Powerclad PMFR
Thickness (mm) 0.401 0.401
Weight (g/m2) 200 ±5% 240 ±5%
Cert. No. 727a/01 727a/02
Notes: 1) LPCB ref No. 727a/01 & 727a/02, the material thickness includes the reinforcing mesh. 2) LPCB Ref. No’s. 727a/01 and 727a/02 covers printed and non printed Powerclad SDFR and PMFR materials with a printed product marking band as required by LPS 1207: Issue 2 Clause 4.
Certificate No: 965a to LPS 1207 Issue 2.1 Product Name Powerclad PMFR
Thickness (mm) 0.50 ±7%
Weight (g/m2) 230 ±7%
Cert. No. 965a/01
Notes: 1. LPCB Ref. No. 965a/01 the material thickness includes the reinforcing mesh 2. LPCB Ref. No. 965a/01 covers non printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4.
IPB N.V. Steenovenstraat 30, B-8790 Waregem, Belgium Tel: UK Sales +44 (0)800 834704 • Fax: +44 (0)800 834705 Certificate No: 365a to LPS 1207: Issue 1 Product Name Proplex
Thickness (mm) 2.0 to 4.0
Weight (g/m2 ) 250 to 1000
Cert. No. 365a/01
Landskroon B.V. Tweelingenlaan 43, 7324 AP Apeldoorn, PO Box 195, 7300 AD Apeldoorn, The Netherlands Tel: +31(0) 555 999 555 • Fax: +31(0) 555 340 200 E-mail: [email protected] • Website: www.landskroon.nl Certificate No: 915a to LPS 1207: Issue 2 Product Name Lankotex Scaffold TARP 220FR Lankotex Scaffold TARP 170FR
Thickness (mm) 0.7 ± 5% 0.7 ± 5%
Weight (g/m²) 220 +7/ - 5% 170 ± 10%
Cert. No. 915a/01 915a/02
Note: 1. LPCB Ref No. 915a/01 and 915a/02 are available in white only and cover non printed material with a printed product marking band as required by LPS 1207 Issue 2 Clause 4 only.
166
20 Nov 2011
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING
Monarflex Lyskaer 10,, DK-2730 Herlev, Copenhagen, Denmark Tel: +45 44 88 55 50 • Fax: +45 44 88 55 99 E-mail: [email protected] • Website: www.special-fire.com Certificate No: 540a to LPS 1207: Issue 2 Product Name
Cert. No.
Weight (g/m2 ) 206 to 252 119 to 132
HD Barrier Film MD Barrier Film
540a/01
Nields Plastic Company Limited Units 1 -2, Foley Works Estate, Hereford HR1 2SF, United Kingdom Tel: +44 (0)1432 268341 • Fax: +44 (0)1432 353247 E-mail: [email protected] Certificate No: 342a to LPS 1207: Issue 1 Product Name Antimar
Thickness (mm) 0.05 to 0.3
Weight (g/m2 ) 47 to 280±15%
Cert. No. 342a/01
Northern Ireland Plastics Limited 39 Shrigley Road, Killyleagh, Co. Down, Northern Ireland BT30 9SR, United Kingdom Tel: +44 (0)2844 828753/4 • Fax: +44 (0)2844 828809 E-mail: [email protected] Certificate No: 341a to LPS 1207: Issue 2 Product Name
Thickness (mm) 2.3 ± 0.5 2.3 ± 0.5
Corriboard Twin Wall (white) Corriboard Twin Wall (black)
Weight (g/m2 ) 200 to 800 200 to 800
Cert. No. 341a/01 341a/02
Note: 1. LPCB Ref. No. 341a/01 & 341a/02 covers printed and non printed materials with a printed product marking band as required by LPS 1207 Issue 2 clause 4.
Ockwells Limited Unit 6, Transigo, Gables Way, Thatcham, Berkshire RG19 4ZA, United Kingdom Tel: +44 (0)1635 876336 • Fax: +44 (0)1635 876338 E-mail: [email protected] • Website: www.ockwells.co.uk Certificate No: 726a-x1 to LPS 1207: Issue 2 Product Name Floorshield FR
20 Nov 2011
Thickness (mm) 0.5 nominal
Weight (g/m²) 100 ±6%
Cert. No. 726a-x1/01
167
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING
Certificate No: 341a-x1 to LPS1207: Issue 2 Product Name
Weight (g/m²) 200 - 800 200 - 800
Thickness (mm) 2.3 ± 0.5 2.3 ± 0.5
Ockwells Twinshield (White) Ockwells Twinshield (Black)
Cert. No. 341a-x1/01 341a-x1/02
Note: 1. LPCB Ref. No. 341a-x1/01 & 341a-x1/02 covers printed and non printed materials with a printed product marking band as required by LPS 1207 Issue 2 clause 4. Certificate No: 742a-x1 to LPS 1207: Issue 2 Product Name Ockwells Twinshield (Natural colour)
Thickness (mm) 2.0 to 10.0
Cert. No.
Weight (g/m2) 270 to 2000 ± 10%
742a-x1/01
Certificate No: 688a-x2 to LPS1207: Issue 2 Product Name Ockwells Twinshield
Weight (g/m²) 250 - 1000
Thickness (mm) 2.0 - 4.5
Cert. No. 688a-x2/01
Note: 1. LPCB Ref No. 688a-x2/01 is available in white only and covers printed and non printed material with a product marking band as required by LPS 1207: Issue 2 Clause 4.
Ondaplast SpA Via Crocetta, 3310, 47020 Longiano (FC), Italy Tel: +39 0547 56616 • Fax: +39 0547 54087 E-mail: [email protected] • Website: www.ondaplast.com Certificate No: 742a to LPS 1207: Issue 2 Product Name RE-FLAM twin wall flame retardant sheet, natural colour
Thickness (mm) 2.0 to 10.0
Cert. No.
Weight (g/m2) 270 to 2000 ± 10%
742a/01
Protec International Limited Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601 E-mail: [email protected] • Website: www.protection.co.uk Certificate No: 843a to LPS 1207: Issue 2 Product Name Proplex Promesh 1207 Protec Flame Retardant Barrier Sheet CushionGard FR Breathershield FR FR Carpet Shield FR Polythene - White
168
Thickness (mm) 2.0 to 4.0 0.12 to 0.43 0.45 4.0 nominal 0.5 nominal 0.065 ± 7% 0.05 to 0.25 ± 5%
Weight (g/m2 250 to 1000 85 to 210 ± 5% 170 155 ± 10% 100 ± 6% 80 ± 10% 50.2 to 247.25 ± 5%
Cert. No. 365a/01 495a/01 495a/03 843a/01 843a/02 894a/01 894a/02
20 Nov 2011
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING Notes: 1. LPCB Ref. No. 495a/03, the material thickness of the Protec Flame retardant barrier sheet includes the textured profile. 2. LPCB Ref. No. 495a/02, 843a/01 & 894/01 covers printed and non-printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4. 3. LPCB Ref. No. 495a/01, 495a/03 & 894a/02 covers non printed material with a printed product marking band as required by LPS 1207 Issue 2 Clause 4 only. 4. LPCB Ref. No. 894a/01, the thickness quoted is the material thickness pre-embossed. 5. LPCB Ref. No. 849a/01, the approval products are self-adhesive films.
Protecta Screen Ltd 5 Driberg Way, Braintree, Essex CM17 1NB, United Kingdom Tel: +44 (0)870 1218670 • Fax: +44 (0)870 1218680 E-mail: [email protected] • Website: www.protectascreen.com Certificate No: 688a-x3 to LPS1207: Issue 2 Product Name Protectaboard
Thickness (mm) 2.0 - 3.0
Weight (g/m²) 270 - 450
Cert. No. 688a-x3/01
Sealed Air Limited Telford Way, Kettering, Northants NN16 8UN, United Kingdom Tel: +44 (0)1886 884 747 • Fax: +44 (0)1886 884 125 E-mail: [email protected] • Website: www.special-fire.com Certificate No: 505a to LPS 1207: Issue 2 Product Name Cushion Wrap 1207
Thickness (mm) approx 4.2
Weight (g/m2 ) 118 ± 2
Cert. No. 505a/01
Note: LPCB Ref No. 505a/01 covers printed and non-printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4.
Sealed Air Limited Telford Way, Kettering, Northants NN16 8UN, United Kingdom Tel: 01536 315 700 • Fax: 01536 315 702 E-mail: [email protected] • Website: www.sealedair.com Certificate No: 505b to LPS 1207: Issue 2 Product Name CMFR
Thickness (mm) approx.4.2
Weight g/m2) 60 ± 2
Cert. No. 505b/02
Note: 1. LPCB Ref. No. 505b/02 is available in white only and covers non printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4 only.
20 Nov 2011
169
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING
Solicom SA Rue de Drinklange 9, L-9911 Troisvierges, Luxembourg Tel: +352 26957256 • Fax: +352 26958056 E-mail: [email protected] • Website: www.verisafe.be Certificate No: 789a to LPS 1207: Issue 2 Product Name
Thickness (mm) 0.20 ±5% 0.40 ±5% 0.28 +5/-10%
Verisafe 200 (White) Verisafe 400 (White) Verisafe B1 280 (White)
Weight (g/m 2) 200 ±5% 400 ±5% 280 +5/-7%
Cert. No. 789a/01 789a/02 789a/03
Note: 1. LPCB Ref. No. 789a/01, 789a/02 & 789a/03 are available in white only and cover non-printed Verisafe material as specified with a printed product marking band as required by LPS 1207: Issue 2 Clause 4 only.
Sunjüt A.S. Yukari Dudullu, Organize San, Bölgesi I Cad. No. 29, Umraniye 34775, Istanbul, Turkey Tel: +44 (0)800 834704 • Fax: +44 (0)800 834705 Certificate No: 495a to LPS 1207: Issue 2 Product Name Promesh 1207 Protec Flame Retardant Barrier Sheet
Thickness (mm) 0.12 to 0.43 0.45
Weight (g/m2 ) 85 to 210 ± 5% 170
Cert. No. 495a/01 495a/03
Notes: 1. LPCB Ref. No. 495a/03 The material thickness of the Protec flame retardant Barrier sheet includes the textured profile. 2. LPCB Ref. No. 495a/01 & LPCB Ref. No. 495a/03 covers non printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4 only.
The Blinking Lamp Company Ltd Unit F, Motorway Distribution Centre, Avonmouth Way, Bristol BS11 9YT, United Kingdom Tel: +44(0) 1179 828180 • Fax: +44(0) 1179 382818 E-mail: [email protected] • Website: www.blinkinglamp.co.uk Certificate No: 915a-x1 to LPS 1207 : Issue 2 Product Name Tri-Flex HD FR Tri-Flex FR
Thickness (mm) 0.7 ± 5% 0.7 ± 5%
Weight (g/m²) 220 +7 / - 5% 170 ± 10%
Cert. No. 915a-x1/01 915a-x1/02
Note: 1. LPCB Ref No. 915a-x1/01 and 915a-x1/02 are available in white only and covers non printed material with a printed product marking band as required by LPS 1207 Issue 2 Clause 4 only.
170
20 Nov 2011
PART 1: SECTION 5.1.1 LPS 1207 PROTECTIVE COVERING MATERIALS - SHEETING
Total Polyfilm Limited Armytage Road, The Industrial Estate, Brighouse, West Yorkshire HD6 1PT, United Kingdom Tel: +44 (0)1484 714313 • Fax: +44 (0)1484 720452 Certificate No: 527a to LPS 1207: Issue 2
Frapol Sheeting Product Name Frapol HD Frapol LD Frapol MD
Thickness (mm) 0.200 to 0.300 ± 10% 0.50 to 0.99 ± 10% 0.100 to 0.199 ± 10%
Cert. No.
Weight (g/m2 ) 186 to 279 ± 10% 46 to 92 ± 10% 93 to 185 ± 10%
527a/01
Note: 1. LPCB Ref No 527a/01 covers printed and non printed materials with a printed product marking band as required by LPS1207: Issue 2 Clause 4. The approval covers natural (white) and pigmented film.
Twinplast Limited Unit 2, Greycaine Road, Watford, Hertfordshire WD24 7GP, United Kingdom Tel: +44 (0)1923 230191/817761 • Fax: +44 (0)1923 817756 E-mail: [email protected] • Website: www.twinplast.co.uk Certificate No: 375a to LPS 1207: Issue 2 Product Name Twinplast / Antinox FR Protection Board (white) Twinplast / Antinox FR Protection Board (white, black or coloured) Twinplast / Antinox Antistatic FR Protection Board (white) Twinplast / Antinox Recycled FR Protection Board (black)
Thickness (mm) 2.0 to 6.0 2.0 2.0 to 4.0 4.0 2.0
Weight (g/m2 ) 250 to 1400 200 to 250 250 to 1000 700 250
Cert. No. 375a/01 375a/02 375a/03 375a/04 375a/05
Note: 1. LPCB Ref Nos. 375a/01, 375a/02, 375a/03, 375a/04 and 375a/05 covers printed and non printed materials with a printed product marking band as required by LPS1207: Issue 2 Clause 4.
Univar Speciality Consumables Armstrong Road, The Royal Arsenal, London SE18 6RS, United Kingdom Tel: +44 (0)20 8312 7200 • Fax: +44 (0)20 8312 7250 E-mail: [email protected] • Website: www.univareurope.com Certificate No: 709a to LPS 1207: Issue 2 Product Name MP70TRA twin wall fluted sheet MP70BLA twin wall fluted sheet MP70WHI twin wall fluted sheet
Thickness (mm) 2.0 2.0 2.0
Weight (g/m2) 250 ± 10 250 ± 10 250 ± 10
Cert. No. 709a/01 709a/02 709a/03
Note: 1. LPCB Ref. No. 709a/01, 709a/02 & 709a/03 covers printed and non printed materials with a printed product marking band as required by LPS1207: Issue 2 Clause 4.
20 Nov 2011
171
PART 1: SECTION 5.1.2 LPS 1207 PROTECTIVE COVERING MATERIALS - PRE-FORMED
Ockwells Limited Unit 6, Transigo, Gables Way, Thatcham, Berkshire RG19 4ZA, United Kingdom Tel: +44 (0)1635 876336 • Fax: +44 (0)1635 876338 E-mail: [email protected] • Website: www.ockwells.co.uk Certificate No: 898a to LPS1207: Issue 2 Product Name Ockwells 048 Universal Foam Protector - Flame Retardant Ockwells114 Universal Foam Protector - Flame Retardant Ockwells 90/110 Universal Foam Protector - Flame Retardant
Wall Thickness (mm) 13 ± 1 13 ±1 13 ± 1
Size Range (mm)
Density (g/m³)
Cert. No.
O-Profile 48 O-Profile 114 U-Profile 90/110
36 ± 3 36 ± 3 36 ± 3
898a/01 898a/02
Note: 1. LPCB Ref. No. 898a/01 & 898a/02 is available in Orange only and covers non printed material with a printed product marking band as required by LPS 1207: Issue 2 Clause 4 only.
Protec International Limited Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601 E-mail: [email protected] • Website: www.protection.co.uk Certificate No: 843b to LPS 1207: Issue 2 Product Name Protective Foam Tubing (Red)
172
Wall Thickness (mm) 13 -1/+0.5
Size Range (mm) Internal dia. 15 to 114
Density 3)
Cert. No.
30±5
634a/01
20 Nov 2011
PART 1: SECTION 5.2 LPS 1215 SCAFFOLD CLADDING MATERIALS
Scaffold cladding materials such as sheeting and netting are often used externally during construction, refurbishment or demolition of buildings to provide protection. Historically, there have been a number of significant losses associated with fires involving scaffolding. Scaffold cladding materials should not add to the fire risk if they comply with LPS 1215 Requirements for the LPCB approval and listing of scaffold cladding materials. Note: LPS 1215:Issue 3 does not cover other features required of scaffold materials, such as resistance to wind, rain penetration, resistance to tearing or impact damage.
Envirowrap Solutions Limited Registered Office:, Strangford House, Church Road, Ashford, Kent TN23 3QR, United Kingdom Tel: +44 (0)1233 860080 • Fax: +44 (0)1233 860090 E-mail: [email protected] • Website: www.envirowrap.info Certificate No: 691b to LPS 1215: Issue 3
Envirowrap 250, 300, 350 & 400AFR-T D06-08 Product Name
Thickness (mm) 0.25 ± 5% 0.30 ± 5% 0.35 ± 5% 0.40 ± 5%
Envirowrap 250AFR-T D06-08 Envirowrap 300AFR-T D06-08 Envirowrap 350AFR-T D06-08 Envirowrap 400AFR-T D06-08
Weight (g/m2) 253 ± 5% 305 ± 5% 348 ± 5% 399 ± 5%
Cert. No. 691b/02
Note: 1. LPCB Ref No. 691b/02 is available in white/light cream only and covers non printed product material with a printed product marking band as required by LPS 1215 Issue 3 Clause 4.
Gilray Plant Limited Cedar Depot, Church Manorway, Erith, Kent DA8 1DE, United Kingdom Tel: 01322 442006 • Fax: 01322 442009 E-mail: [email protected] • Website: www.gilray.co.uk Certificate No: 915b-x2 to LPS 1215 Issue 3 Product Name Fire-Retardant Multisheet 220 FR Fire-Retardant Multisheet 170 FR
Thickness (mm) 0.7 ± 5% 0.7 ± 5%
Weight (g/m²) 220 +7/ - 5% 170 ± 10% 225 ± 10% (incl. printing)
Cert. No. 915b-x2/01 915b-x2/02
Notes: 1. LPCB Ref No. 915b-x2/01 is available in white only and covers non printed material with a printed product marking band as required by LPS 1215 Issue 3 Clause 4 only. 2. LPCB Ref No. 915b-x2/02 is available in white only and covers printed and non printed material with a printed product marking band as required by LPS 1215 Issue 3 Clause 4. Certificate No: 1061a-x2 to LPS 1215: Issue 3
Flame Retardant Debris Netting Product Name Flame Retardant Debris Netting
Thickness (mm 0.75 ± 10%
Weight (g/m²) 85 ± 15%
Cert. No. 1061a-x2/01
Notes: 1. LPCB Ref No. 1061a-x2/01 is available in Blue, White, Black, Green, Red, Yellow and Orange and is non-printed material as specified with a printed product marking band as required by LPS1215 Issue 3 clause 4 only.
20 Nov 2011
173
PART 1: SECTION 5.2 LPS 1215 SCAFFOLD CLADDING MATERIALS
Icopal Limited Barton Dock Road, Stretford, Manchester M32 0YL, United Kingdom Tel: +44 (0)161 865 4444 • Fax: +44 (0)161 865 8433 E-mail: [email protected] • Website: www.icopal.co.uk Certificate No: 572d to LPS 1215: Issue 3 Product Name
Thickness (mm) 0.15 Nominal 0.2 to 0.55 0.2 to 0.55
Monarflex Stripe Firesmart Monarflex Super T Plus Firesmart Monarflex Temporary Roof Cover Flamesafe
Weight (g/m2) 210 ± 5% 275 ± 5% 233 ± 10%
Cert. No. 540d/01 572d/01 572d/02
Notes: 1. LPCB Ref. No. 572d/01 & 572d/02 Monarflex Super T Plus Firesmart roll size 2.25m x 40m, 2m x 45m, 3m x 45m and 4m x 36m. Monarflex Temporary Roof Cover Flamesafe roll size 23.35m x 50m and 3.35m x 30m. Products produced at Monarflex s.r.o 2. LPCB Ref. No. 572d/01 covers printed and non printed materials with a printed product marking band as required by LPS1215: Issue 3 Clause 4. 3. LPCB Ref. No. 540d/01 is available in white only and covers non printed materials with a printed product marking band as required by LPS1215: Issue 3 Clause 4 only.
Industrial Textiles & Plastics Ltd Stillington Road, Easingwold, York YO61 3FA, United Kingdom Tel: +44 (0)1347 825200 • Fax: +44 (0)1347 825222 E-mail: [email protected] • Website: www.powerclad.com
Certificate No: 727b to LPS 1215: Issue 3
Powerclad Product Name Powerclad SDFR Powerclad PMFR
Thickness (mm) 0.40 0.40
Weight (g/m2) 200 ±5% 240 ±5%
Cert. No. 727b/01 727b/02
Notes: 1. LPCB Ref. No. 727b/01 & 727b/02, the material thickness includes the reinforcing mesh. 2. LPCB Ref. No. 727b/01 and 727b/02 covers printed and non printed Powerclad SDFR and PMFR material with a printed product marking band as required by LPS 1215: Issue 3 Clause 4. Certificate No: 965b to LPS1215 Issue 3.1 Product Name Powerclad PMFR Powerclad SDFR Powerclad RSFR
Thickness (mm) 0.50 ±7% 0.20 ±5% 0.40 ±10%
Weight (g/m2) 230 ±7% 180 ±9% 300 ±10%
Cert. No. 965b/01 965b/02 965b/03
Notes: 1. LPCB Ref No. 965b/01 the material thickness includes the reinforcing mesh. 2. LPCB Ref. No. 965b/01 covers printed and non printed material with a printed product marking band as required by LPS 1215: Issue 3 Clause 4. 3. LPCB Ref. No. 965b/02 & 965b/03 covers non printed material with a printed product marking band as required by LPS 1215: Issue 3 Clause 4.
174
20 Nov 2011
PART 1: SECTION 5.2 LPS 1215 SCAFFOLD CLADDING MATERIALS
Landskroon B.V. Tweelingenlaan 43, 7324 AP Apeldoorn, PO Box 195, 7300 AD Apeldoorn, The Netherlands Tel: +31(0) 555 999 555 • Fax: +31(0) 555 340 200 E-mail: [email protected] • Website: www.landskroon.nl Certificate No: 915b to LPS1215: Issue 3 Product Name Lankotex Scaffold TARP 220FR Lankotex Scaffold TARP 170FR
Thickness (mm) 0.7 ± 5% 0.7 ± 5%
Weight (g/m²) 220 +7 /- 5% 170 ± 10% 225 ± 10% (incl. printing)
Cert. No. 915b/01 915b/02
Notes: 1. LPCB Ref No. 915b/01 is available in white only and covers non printed material with a printed product marking band as required by LPS 1215 Issue 3 Clause 4 only. 2. LPCB Ref No. 915b/02 is available in white only and covers printed and non printed material with a printed product marking band as required by LPS 1215 Issue 3 Clause 4.
Protec International Limited Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601 E-mail: [email protected] • Website: www.protection.co.uk Certificate No: 843c to LPS 1215: Issue 3 Product Name Proscaff Premium FR Scaffnet FR (white)
Thickness (mm) 0.60 0.30 (single yarn)
Weight (g/m2 250 65±5%
Cert. No. 495b/01 495b/02
Notes: 1. LPCB Ref. 495b/01 Covers printed and non printed materials with a printed product marking band as required by LPS 1215: Issue 3 Clause 4.
Solicom SA Rue de Drinklange 9, L-9911 Troisvierges, Luxembourg Tel: +352 26957256 • Fax: +352 26958056 E-mail: [email protected] • Website: www.verisafe.be Certificate No: 789b to LPS 1215: Issue 3 Product Name Verisafe 320 (White) Verisafe 400 (White) Verisafe B1 280 (White)
Thickness (mm) 0.32 ±5% 0.40 ±5% 0.28 +5/-10%
Weight (g/m 2) 320 ±5% 400 ±5% 280 +5/-7%
Cert. No. 789b/01 789b/02 789b/03
Note: 1. LPCB Ref. No. 789b/01, 789b/02 & 789b/03 are available in white only and cover non-printed Verisafe material as specified with a printed product marking band as required by LPS 1215: Issue 3 Clause 4 only.
20 Nov 2011
175
PART 1: SECTION 5.2 LPS 1215 SCAFFOLD CLADDING MATERIALS
Sunjüt A.S. Yukari Dudullu, Organize San, Bölgesi I Cad. No. 29, Umraniye 34775, Istanbul, Turkey Tel: +44 (0)800 834704 • Fax: +44 (0)800 834705 Certificate No: 495b to LPS 1215: Issue 3 Product Name
Thickness (mm) 0.60 0.30 (single yarn)
Proscaff Premium FR Scaffnet FR (white)
Weight (g/m2 ) 250 65 ± 5%
Cert. No. 495b/01 495b/02
Note: 1 LPBC Ref. 4965b/01 Covers printed and non printed materials with a printed product marking band as required by LPS1215: Issue 3 Clause 4
The Blinking Lamp Company Ltd Unit F, Motorway Distribution Centre, Avonmouth Way, Bristol BS11 9YT, United Kingdom Tel: +44(0) 1179 828180 • Fax: +44(0) 1179 382818 E-mail: [email protected] • Website: www.blinkinglamp.co.uk Certificate No: 915b-x1 to LPS 1215: Issue 3 Product Name Tri-Flex HD FR Tri-Flex FR
Thickness (mm) 0.7 ± 5% 0.7 ± 5%
Weight (g/m²) 220 +7/ - 5% 170 ± 10% 225 ± 10% (incl. printing)
Cert. No. 915b-x1/01 915b-x1/02
Notes: 1. LPCB Ref No. 915b-x1/01 is available in white only and covers non printed material with a printed product marking band as required by LPS 1215 Issue 3 Clause 4 only. 2. LPCB Ref No. 915b-x1/02 is available in white only and covers printed and non printed material with a printed product marking band as required by LPS 1215 Issue 3 Clause 4. Certificate No: 1061a-x1 to LPS 1215: Issue 3 Product Name Tri-Net FR
Thickness (mm) 0.75 ± 10%
Weight (g/m²) 85 ± 15%
Cert. No. 1061a-x1/01
Notes: 1. LPCB ref No. 1061a-x1/01 is available in Blue, White, Black Green, Red, Yellow and Orange and is non-printed material as specified with a printed marking band as required by LPS1215 Issue 3 clause 4 only.
176
20 Nov 2011
PART 1: SECTION 6 CAVITY FIRE BARRIERS
The materials listed in this section can be used to sub-divide such voids as service shafts, roof and floor spaces and restrict the spread of fire. In the absence of a specific test standard for cavity barriers these products meet the performance requirements of BS 476:Part 22:1987 Methods for determination of the fire resistance of non-loadbearing elements of construction or BS EN 1364-1Fire resistance tests for nonloadbearing elements, walls or 1364-2 Fire resistance tests for non-loadbearing elements, ceilings as set down in Approved Document B. The LPC Design Guide for the Fire Protection of Buildings: 2000 covers the design issues in Section 4.5. The assessment methodology used in LPS 1208 also applies to the performance assessment for these products.
Culimeta-Saveguard Limited Tame Valley Mill, Wainwright Street, Dukinfield, Cheshire SK16 5NB, United Kingdom Tel: +44 (0)161 344 2484 • Fax: +44 (0)161 344 2486 E-mail: [email protected] Certificate No: 552a to LPS 1208: Issue 2 Product Name
Specification (m)
FireHalt Gold
3.0 long x 1.2 wide
Fire Resistance (min) Integrity 132
Fire Resistance (min) Insulation 38
Cert. No.
552a/01
Notes: 1. The barriers can only be installed vertically. 2. Joints between individual runs in a barrier must be fixed using 12mm staples at 50mm centres.
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022c to LPS 1208: Issue 2 Product Name
Product
Specification
Rockwool Firepro Fire Barrier System
½ hour Fire Barrier ½ hour Cavity Barrier 1 hour Fire Barrier 1½ Hour Fire Barrier 2 hour Fire Barrier
1 layer 60mm Fire Barrier foil faced overlapped joints 1 layer 50mm thick 2 layers 50mm Fire Barrier staggered vertical joints 2 layers 50mm Fire Barrier staggered vertical joints 2 layers 60mm Fire Barrier foil faced separated by 40mm air gap
Fire Resistance (min) Integrity 60
Fire Resistance (min) Insulation 30
Grading
Cert. No.
FR30
022c/01
60
15
FR15
60
60
FR60
90
90
FR90
120
120
FR120
Notes: 1. This product is supplied in 1m widths, with a length of 4m for 50mm thick Fire Barrier and 3.5m for 60mm thick Fire Barrier. 2. The maximum allowable drop is 6m without a support frame. Where the additional section is joined the barrier should be overlapped by at least 100mm and stitched. 3. Refer to manufacturer's technical literature for fixing details.
20 Nov 2011
177
PART 1: SECTION 6 CAVITY FIRE BARRIERS
Certificate No: 022c to LPS1208: Issue 2
Rockwool Firepro Fire Barrier Slab Product Name
Cavity Width (mm)
Slab Size (mm)
Rockwool Firepro Fire Barrier Slab
Up to 1000
1000 x 600 x 100
Fire Resistance (min) Integrity 240
Fire Resistance (min) Insulation 60
Grade
Cert. No.
FR60
022c/02
Notes: 1. Where the slab is penetrated by services, the fire resistance is reduced to 90 minutes integrity and 60 minutes insulation. The size of the penetrations should not exceed steel pipes having a diameter of 33.5mm external diameter, or steel cable trays 305mm wide x 50mm high x 0.9mm thick. Rockwool Acoustic and Fire Sealant should also be applied to all butt edges to form a tight bond when a penetration passes through the slab. The Acoustic and Fire Sealant should be tapered from 16mm deep at the face of the slab to nothing at a distance of 40mm on both faces. 2. Refer to manufacturer's technical literature for fixing details.
178
20 Nov 2011
PART 1: SECTION 7 LPS 1195 TEMPORARY BUILDINGS FOR USE ON CONSTRUCTION SITES
Temporary buildings are widely used on construction sites as site offices, canteens and rest areas etc. On some large construction sites the number of temporary buildings can form a virtual village; a fire starting in one of these temporary buildings could be catastrophic if the fire were to break out and spread to other temporary buildings or to the building under construction. LPS 1195:Part 1 Specification for Testing of Temporary Buildings for Use on Construction Sites specifies the test and performance requirements for temporary buildings for use on construction sites at locations less than 6m from buildings under construction/refurbishment. The basic objective is to prevent a fire which has started in a temporary building from spreading to adjacent combustible materials, other temporary buildings or to the building under construction. A temporary building tested and approved by LPCB to this standard can be regarded as meeting the appropriate requirements of “The Joint Code of Practice on the Protection from Fire of Construction Sites and Buildings Undergoing Renovation”.
McAvoy Group Limited 2 Ferguson Road, Knockmore Hill Industrial Estate, Lisburn, Co Antrim BT28 2FW, United Kingdom Tel: +44 (0)870 2408987 • Fax: +44 (0)28 8774 88495 E-mail: [email protected] • Website: www.mcavoygroup.com Certificate No: 728a to LPS 1195: Part 1: Issue 4 Product Name SafeSpace Fire rated office
Maximum Size (mm) & Configurations 9750(L) x 3040(W) x 3040(H) See Note 1
Maximum Supporting Load (note 4) 8.5 tonne
Integrity Performance
Insulation Performance
Irradiance Performance
Cert. No.
30 minutes
30 minutes
0.005 kW/m2
728a/01
Notes: 1. The certification applies to unit configurations as follows; 12FT x 10FT Fire rated office, drawing reference FRO-1210-0-011 16FT x 10FT Fire rated office, drawing reference FRO-1610-0-021 20FT x 10FT Fire rated office, drawing reference FRO-2010-0-021 24FT x 10FT Fire rated office, drawing reference FRO-2410-0-021 30FT x 10FT Fire rated office, drawing reference AVO-3010-0-031-08 32FT x 10FT Fire rated office, drawing reference FRO-3210-0-031 Including up to 3 off 1067 x 940mm fire rated timber frame windows with external steel security shutters (Note 2) and, 1 off 762 x 1981mm fire rated timber door with external steel security door (Note 3). 2. Test conducted with steel security shutters in the open position. 3. Test conducted with the steel security door in the closed position. 4. Imposed load applied evenly distributed on a floor section located on the top of the 4 structural corner posts.
20 Nov 2011
179
PART 1: SECTION 8 PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS
The products listed in this section have been assessed for use in rail transport applications in which the means of escape from a fire is limited as a result of:
Difficulties in escaping from moving vehicles. The location of the fire (sub surface tunnels, viaducts, termini). Restricted egress from tunnels and sub surface termini.
Under such circumstances, it is essential that the materials used in the construction and furnishings of vehicles and sub surface constructions have the appropriate fire performance in terms of fire resistance and reaction to fire, including spread of flame, smoke and toxic fume emission. This scheme provides independent third party approval for fire performance of products which have been tested and, where appropriate, classified in accordance with standards and codes of practice recognised by the transport industry or produced by the relevant transport bodies such as London Underground Limited (LUL), International Maritime Organisation (IMO) etc. Products gaining LPCB approval under this scheme are primarily for use in transport applications such as rolling stock, shipping, motor vehicles and within transport infrastructure such as underground tunnels and transport termini.
MCT Brattberg AB SE 37192 Karlskrona, Sweden Tel: +46 (0) 455 451 60 • Fax: +46 (0) 455 451 28 E-mail: [email protected] • Website: www.mctbrattberg.com UK Office: MCT Brattberg Ltd, Commerce Street, Carrs Industrial Estate, Haslingden BB4 5JT, United Kingdom Tel: +44 (0)1706 244890 • Fax: +44 (0)1706 244891 E-mail: [email protected] • Website: www.mctbrattberg.co.uk
Certificate No: 628a to LPS 1132: Issue 4 Product Name
Use
Element of Construction
RGB 2, 4 , 6, 8 & RGB 180, 240 & 360
Cables
Concrete or masonry Floor Concrete or masonry Floor Concrete or masonry Wall Concrete or masonry Wall Concrete or masonry Floor Concrete or masonry Floor Concrete or masonry Wall Concrete or masonry Wall Concrete or masonry Floor Concrete or masonry Floor Concrete or masonry Wall Concrete or masonry Wall
Steel pipe Cables Steel pipes RGBO 2, 4 , 6, 8 & RGBO 180, 240 & 360
Cables Steel pipes Cables Steel pipes
RGP 50, 70, 100, 150, 200 & 300
Cables Steel pipes Cables Steel pipes
180
Fire Resistance (min) Integrity 240
Fire Resistance (min) Insulation 120
240
60
240
60
240
60
240
120
240
60
240
60
240
60
360
120
240
60
360
120
240
60
Cert. No. 628a/01
628a/02
628a/03
20 Nov 2011
PART 1: SECTION 8 PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS Product Name
Use
Element of Construction
RGPO 50, 70, 100, 150, 200 & 300
Cables
Concrete or masonry Floor Concrete or masonry Floor Concrete or masonry Wall Concrete or masonry Wall
Steel pipes Cables Steel pipes
Fire Resistance (min) Integrity 360
Fire Resistance (min) Insulation 120
240
60
360
120
240
60
Cert. No. 628a/04
Note: 1. Please refer to manufacture’s product data for maximum aperture sizes and installation details.
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022e to EN 13501-1: 2002 Product Name
Thickness (mm) 60 - 180 60 - 180 60 - 180 50 - 150
Cladding Roll - Unfaced Cladding Roll - Aluminum foil faced Cladding Roll - White tissue faced Flexi Batts - Unfaced
Test/Assessment Standard EN 13501-1:2002 EN 13501-1:2002 EN 13501-1:2002 EN 13501-1:2002
Classification
Cert. No.
A1 A1 A1 A1
022e/01 022e/04
Certificate No: 022f to BS 476: Part 24: 1987
FirePro™ Fire Duct Systems Product Name
Duct Type
Condition
FirePro™ Fire Duct Systems
Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation horizontal orientation
Fire Outside
20 Nov 2011
Maximum Duct Size (ht x wt) (mm) 1000 x 1000
Insulation Thickness (mm)
Fire Outside
25
Fire Resistance Integrity (min) 30
Fire Resistance Insulation (min) 30
1000 x 1000
30
60
60
Fire Outside
1500 x 1500
50
90
90
Fire Outside
1500 x 1500
70
120
120
Fire Outside
1525 dia.
25
30
30
Fire Outside
1525 dia.
30
60
60
Fire Outside
1525 dia.
50
90
90
Fire Outside
1525 dia.
70
120
120
Fire Outside
1000 x 1000
25
30
30
Cert. No. 022f/01
181
PART 1: SECTION 8 PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS Product Name
182
Duct Type
Condition
Maximum Duct Size (ht x wt) (mm) 1500 x 1500
Insulation Thickness (mm)
Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation
Fire Outside Fire Outside
40
Fire Resistance Integrity (min) 60
Fire Resistance Insulation (min) 60
1200 x 1200
70
90
90
Fire Outside
1000 x 1000
90
120
120
Fire Outside
1525 dia.
25
30
30
Fire Outside
1525 dia.
40
60
60
Fire Outside
1525 dia.
70
90
90
Fire Outside
1525 dia.
90
120
120
Fire Inside
1000 x 1000
25
30
30
Fire Inside
1000 x 1000
30
60
60
Fire Inside
1500 x 1500
50
90
90
Fire Inside
1500 x 1500
70
120
120
Fire Inside
1525 dia.
25
30
30
Fire Inside
1525 dia.
30
60
60
Fire Inside
1525 dia.
50
90
90
Fire Inside
1525 dia.
70
120
120
Fire Inside
1000 x 1000
25
30
30
Fire Inside
1500 x 1500
40
60
60
Fire Inside
1200 x 1200
70
90
90
Fire Inside
1000 x 1000
90
120
120
Fire Inside
1525 dia.
25
30
30
Fire Inside
1525 dia.
40
60
60
Fire Inside
1525 dia.
70
90
90
Fire Inside
1525 dia.
90
120
120
Cert. No.
20 Nov 2011
PART 1: SECTION 8 PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS Product Name
20 Nov 2011
Duct Type
Condition
Maximum Duct Size (ht x wt) (mm) 1000 x 1000
Insulation Thickness (mm)
Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet vertical orientation
Fire Outside Fire Outside
25
Fire Resistance Integrity (min) 30
Fire Resistance Insulation (min) 30
1000 x 1000
30
60
60
Fire Outside
1500 x 1500
50
90
90
Fire Outside
1500 x 1500
70
120
120
Fire Outside
1525 dia.
25
30
30
Fire Outside
1525 dia.
30
60
60
Fire Outside
1525 dia.
50
90
90
Fire Outside
1525 dia.
70
120
120
Fire Outside
1000 x 1000
25
30
30
Fire Outside
1500 x 1500
40
60
60
Fire Outside
1200 x 1200
70
90
90
Fire Outside
1000 x 1000
90
120
120
Fire Outside
1525 dia.
25
30
30
Fire Outside
1525 dia.
40
60
60
Fire Outside
1525 dia.
70
90
90
Fire Outside
1525 dia.
90
120
120
Fire Inside
1000 x 1000
25
30
30
Cert. No.
183
PART 1: SECTION 8 PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS Product Name
Duct Type
Condition
Insulation Thickness (mm)
Fire Inside
Maximum Duct Size (ht x wt) (mm) 1000 x 1000
Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet vertical orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Smoke Outlet horizontal orientation Kitchen Extract Kitchen Extract
Fire Inside
30
Fire Resistance Integrity (min) 60
Fire Resistance Insulation (min) 60
1500 x 1500
50
90
90
Fire Inside
1500 x 1500
70
120
120
Fire Inside
1525 dia.
25
30
30
Fire Inside
1525 dia.
30
60
60
Fire Inside
1525 dia.
50
90
90
Fire Inside
1525 dia.
70
120
120
Fire Inside
1000 x 1000
25
30
30
Fire Inside
1500 x 1500
40
60
60
Fire Inside
1200 x 1200
70
90
90
Fire Inside
1000 x 1000
90
120
120
Fire Inside
1525 dia.
25
30
30
Fire Inside
1525 dia.
40
60
60
Fire Inside
1525 dia.
70
90
90
Fire Inside
1525 dia.
90
120
120
Fire Outside Fire Outside
1500 x 1500
40
30
30
1000 x 1000
90
60
60
Cert. No.
Certificate No: 22b to LPS 1132: Issue 4
184
20 Nov 2011
PART 1: SECTION 8 PRODUCTS ASSESSED FOR USE IN SURFACE AND SUB SURFACE TRANSPORT APPLICATIONS FirePro TM Acoustic Intumescent sealant Product Name
Element of Construction Orientation
Element of Construction Thickness (mm)
Element of Construction Material
Maximum Joint Width (mm)
Configeration: Fire Side Depth of Sealant (mm)
Configeration: Configeration: Backing Material
FirePro ™ Acoustic Intumescent Sealant
floor
230
AC/AC
50
25
Ethafoam 50mm
floor
230
Softwood/AC
25
12
floor
230
Hardwood/AC
50
25
floor
230
Steel/AC
50
25
floor
250
AC/AC
30
15
floor
250
AC/AC
15
10
floor
250
AC/AC
20
floor
250
AC/AC
50
floor
250
AC/AC
10
floor
250
AC/AC
25
floor
250
Hardwood/AC
15
10
floor
250
Steel/AC
15
10
Ethafoam 30mm Ethafoam 50mm Ethafoam 50mm Ethafoam 40mm Ethafoam 25mm Polyethylene 20mm Polyethylene 50 x 25mm Polyethylene 0mm Polyethylene 25mm Ethafoam 15mm Ethafoam 25mm Polyethylene 30 x 15 Polyethylene 15 x 15 Polyethylene 10 x 15 Polyethylene 10 x 15 Polyethylene 15 x 15 Polyethylene 30 x 15 Ethafoam 50mm Ethafoam 50mm Ethafoam 30mm Ethafoam 50mm Ethafoam 40mm Ethafoam 25mm Ethafoam 25mm Ethafoam 25mm Polyethylene 20mm Polyethylene 40mm Polyethylene 10mm Polyethylene 25mm
wall
150
AC/AC
30
30
wall
150
AC/AC
15
15
wall
150
AC/AC
10
10
wall
150
AC/AC
10
10
wall
150
AC/AC
15
15
wall
150
AC/AC
30
30
wall
200
AC/AC
50
25
wall
200
Hardwood/AC
50
25
wall
200
Softwood/AC
25
12
wall
200
Steel/AC
50
25
wall
215
AC/AC
30
15
wall
215
AC/AC
15
10
wall
215
Hardwood/AC
15
10
wall
215
Steel/AC
15
10
wall
250
AC/AC
20
wall
250
AC/AC
40
wall
250
AC/AC
10
wall
250
AC/AC
25
Configeration: Non-fire Side Depth of Sealant (mm)
Fire Resistance (min) Integrity (E) 155
Fire Resistance (min) Insulation (I) 105
51
44
47
47
72
62
243
65
243
29
10
155
47
25
240
92
6
240
207
15
240
73
53
53
243
29
30
265
265
15
265
230
10
265
265
200
166
227
227
240
233
245
82
96
93
55
54
77
39
243
44
243
29
40
29
243
16
10
240
122
20
240
95
10
240
240
20
240
126
Cert. No.
022b/05
Note: AC – Aerated Concrete. Ethafoam – Open cell polyethylene foam rod Please refer to Rockwool installation instructions for further details
20 Nov 2011
185
PART 1: SECTION 9 FIRE PROTECTED TIMBER STAIRS
The timber escape stairs listed in this section are assessed against the requirements of Scheme Document SD 198 which details the requirements of the approval and certification process, and BD2569 Fire Performance of Escape Stairs Guidance Document which details the method of test and assessment for escape stairs based on a realistic fire scenario. The procedure consists of a fire test to evaluate the reactionto-fire performance of the stair assembly and a subsequent load test to evaluate the structural performance of the stair assembly following a fire incident. The scheme applies only to stairs used in: · Single occupancy dwellings · Communal areas in blocks of flats · Areas where people may congregate as defined in Table 1 of BS 6399-13. This approval scheme is run in partnership with the British Woodworking Federation (BWF).
Jeld-Wen UK Ltd Snow Hill, Melton Mowbray, Leicestershire LE13 1PD, United Kingdom Tel: 0845 122 2890 E-mail: [email protected] • Website: www.jeld-wen.co.uk/stairs Certificate No: 1023a to SD198/BD2569 Fire Protected Timber Escape Stair
Fire Protected Timber Escape Stair Product Name
Stair Geometry
Timber Type Treads/Risers
Jeld-Wen Fire Protected Stair
Straight flight
FR MDF / FR MDF
Timber Type Other Timber Components (Strings/handrail, newel posts and balusters) Kerto-S / Hemlock
Straight flight
FR MDF / FR MDF
Kerto-S / Softwood
Straight flight
FR MDF / FR MDF
Kerto-S / Softwood
Dog-leg
Kerto-S / Hemlock
Dog-leg
Parana Pine/Plywood MDF / MDF
Dog-leg
FR MFD / FR MDF
Kerto-S / Hemlock
Dog-leg
Parana Pine/Plywood
Kerto-S / Hemlock
Kerto-S / Hemlock
Stair Treatment applied
Cert. No.
Pressure Impregnation Intumescent coating Jeld-Wen 3 part primer Intumescent coating Intumescent coating Pressure Impregnation Pressure Impregnation
1023a/01 1023a/02 1023a/03 1023a/04 1023a/05 1023a/06 1023a/07
Notes: 1. All stair cases must be under-drawn with a single 12.5mm layer of Type F plasterboard fixed to the strings with 25mm clout nails at 150mm maximum centres. 2. The maximum permitted span for the treads are 1160mm between strings. 3. LPCB ref No. 1023a/04, /05, /06 and /07 Dog-leg systems cover alternative geometries to those tested such as left or right handed returns with a minimum distance of 110mm between return flights and a minimum landing of 2340mm . 4. Approved installation configurations and Timber treatment processes are shown below.
186
20 Nov 2011
PART 1: SECTION 9 FIRE PROTECTED TIMBER STAIRS LPCB ref No. LPCB ref 1023a/01
Component Treatment Process Strings
Dricon pressure impregnation fire 32 x 360 Kerto-S retardant treatment by Arch Chemicals to achieve a Class 1 surface spread of flame*
Treads
None
25mm Euroclass C FR MDF by Premier Forest Products Ltd.
Risers
None
12mm Euroclass C FR MDF by Premier Forest Products Ltd.
Newel posts
Dricon pressure impregnation fire 90mm stop chamfered Hemlock retardant treatment by Arch Chemicals to achieve a Class 1 surface spread of flame* Dricon pressure impregnation fire 63 x 44 Hemlock retardant treatment by Arch Chemicals to achieve a Class 1 surface spread of flame*
Handrail
LPCB ref 1023a/02
Material
Balusters
Dricon pressure impregnation fire 41mm stop chamfered Hemlock retardant treatment by Arch Chemicals to achieve a Class 1 surface spread of flame*
Strings
2 coats of Envirograf ES/VFR fire 32 x 350 Kerto-S protection coating 1215m²/litre/coat for each of 2 coats of base coat applied in accordance with manufacturers instructions
Treads
None
25mm Euroclass B FR MDF by Premier Forest Products Ltd.
Risers
None
12mm Euroclass B FR MDF by Premier Forest Products Ltd.
Newel posts
2 coats of Envirograf ES/VFR fire 90 x 90 softwood square stop protection coating 12chamfered 15m²/litre/coat for each of 2 coats of base coat applied in accordance with manufacturers instructions
Handrail
2 coats of Envirograf ES/VFR fire 63 x 44 softwood profiled protection coating 1215m²/litre/coat for each of 2 coats of base coat applied in accordance with manufacturers instructions
20 Nov 2011
187
PART 1: SECTION 9 FIRE PROTECTED TIMBER STAIRS
LPCB ref 1023a/03
Balusters
2 coats of Envirograf ES/VFR fire 41 x 41 softwood stop chamfered protection coating 1215m²/litre/coat for each of 2 coats of base coat applied in accordance with manufacturers instructions
Strings
Jeld-Wen three part primer applied. All machined edges to be coated with 2 coats of Envirograph ES/VFR.
32 x 350 Kerto-S
Treads
None
25mm Euroclass B FR MDF by Premier Forest Products Ltd
Risers
None
12mm Euroclass B FR MDF by Premier Forest Products Ltd
Newel posts
2 coats of Envirograf ES/VFR fire protection coating 1215m²/litre/coat for each of 2 coats of base coat applied in accordance with manufacturers instructions Jeld-Wen three part primer applied. All machined edges to be coated with 2 coats of Envirograph ES/VFR. Jeld-Wen three part primer applied. All machined edges to be coated with 2 coats of Envirograph ES/VFR. Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
90 x 90 softwood square stop chamfered
Treads
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
27mm Parana Pine
Risers
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
15mm Plywood
Handrail
Balusters
LPCB ref 1023a/04
188
Strings
63 x 44 softwood profiled
41 x 41 softwood stop chamfered
32 x 360 Kerto-S
20 Nov 2011
PART 1: SECTION 9 FIRE PROTECTED TIMBER STAIRS Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions. Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
90mm stop chamfered Hemlock
Balusters
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
41mm stop chamfered Hemlock
Strings
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
32 x 360 Kerto-S
Treads
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
25mm MDF from Premier Forest products Ltd.
Risers
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
12mm MDF from Premier Forest Products Ltd.
Newel posts
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
90mm stop chamfered Hemlock
Handrail
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
63 x 44 Hemlock
Balusters
Aquafire HP coating system comprising a primer, two part basecoat and two part topcoat applied in accordance with manufacturer’s instructions.
41mm stop chamfered Hemlock
Newel posts
Handrail
LPCB ref 1023a/05
20 Nov 2011
63 x 44 Hemlock
189
PART 1: SECTION 9 FIRE PROTECTED TIMBER STAIRS LPCB ref 1023a/06
Strings
Dricon pressure impregnation fire 32 x 360 Kerto-S retardant treatment by Arch Chemicals to achieve a Class O surface spread of flame*
Treads
None
25mm Euroclass B FR MDF by Premier Forest Products Ltd.
Risers
None
12mm Euroclass B FR MDF by Premier Forest Products Ltd.
Newel posts
Dricon pressure impregnation fire 90mm stop chamfered Hemlock retardant treatment by Arch Chemicals to achieve a Class O Dricon pressure impregnation fire 63 x 44 Hemlock retardant treatment by Arch Chemicals to achieve a Class O Dricon pressure impregnation fire 41mm stop chamfered Hemlock retardant treatment by Arch Chemicals to achieve a Class O surface spread of flame*
Handrail
Balusters
LPCB ref 1023a/07
Strings
Dricon pressure impregnation fire 32 x 360 Kerto-S retardant treatment by Arch Chemicals to achieve a Class O surface spread of flame*
Treads
Dricon pressure impregnation fire 27mm Parana Pine retardant treatment by Arch Chemicals to achieve a Class O surface spread of flame*
Risers
Dricon pressure impregnation fire 15mm Plywood retardant treatment by Arch Chemicals to achieve a Class O surface spread of flame*
Newel posts
Dricon pressure impregnation fire 90mm stop chamfered Hemlock retardant treatment by Arch Chemicals to achieve a Class O surface spread of flame*
Handrail
Dricon pressure impregnation fire 63 x 44 Hemlock retardant treatment by Arch Chemicals to achieve a Class O surface spread of flame* Dricon pressure impregnation fire 41mm stop chamfered Hemlock retardant treatment by Arch Chemicals to achieve a Class O surface spread of flame*
Balusters
190
20 Nov 2011
Part 2 FIRE DOORS AND SHUTTERS (INCORPORATING INSTALLER SCHEME FOR FIRE AND SECURITY DOORS)
PART 2: FIRE DOORS AND SHUTTERS (INCORPORATING INSTALLER SCHEME FOR FIRE AND SECURITY DOORS) INTRODUCTION Fire doors and shutters contribute to the passive fire protection of buildings by maintaining the: fire separation of compartment walls, while allowing the passage of persons or objects fire separation in shafts or service ducts that penetrate compartment floors protection provided by walls forming protected routes for means of escape. In addition to careful design and product selection, it is recommended that all products are installed and maintained by LPCB approved contractors who have demonstrated their competence. Products Doors and shutter assemblies are approved in accordance with: LPS 1056: Test and Evaluation Requirements for the Approval and Listing of Fire Doorsets, Lift Landing Doors and Shutter Assemblies. The fire testing element of this LPS is based on BS 476:Part 20 - Method for determination of the fire resistance of elements of construction (general principles) or BS EN 1634-1 Fire resistance test for doors and shutter assemblies- Part 1: Fire doors and shutters, BS EN 81-58 Landing doors fire resistance test and BS EN 1366-7 Fire resistance tests for service installations - Part 7 Conveyor systems and their enclosures. LPS 1056 also includes requirements for the reliability testing of the door and shutter assemblies, and assessment procedures for doors and shutters that are too big to be directly fire tested. Installation contractors LPCB approved installation contractors are assessed in accordance with: LPS 1271: Requirements for Approval and Listing of companies installing fire and security doorsets, shutters and smoke barriers. Maintenance contractors LPCB approved maintenance contractors who repair and maintain fire doors and shutters are approved in accordance with: LPS 1197: Requirements for LPCB Approval and Listing of Companies Undertaking the Maintenance and Repair of Doorsets, Shutters, and Active Smoke/Fire barriers
192
20 Nov 2011
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS
This section lists firebreak doorsets and shutters approved to LPS 1056 Test and Evaluation requirements for the LPCB Approval and Listing of Fire Doorsets, Lift Landing Doors and Shutter Assemblies. LPS 1056 is based upon relevant BS or European test criteria and not only looks at the fire integrity and insulation (where applicable) but also includes reliability cyclic tests and grading. For details of the specific fire resistance required for firebreak doors and shutters for different building types, see the LPC Design Guide for the Fire Protection of Buildings:2000. Where insulation is marked as 0, this denotes that the insulation was not measured or that it could not be measured in accordance with the relevant standard.
Andreu Barbera S.L. Poligono Fuente Del Jarro, C/Ciudad De Sevilla, 20, 46988 Paterna, Valencia, Spain Tel: +34 96134 3100 • Fax: +34 961 34 0859 E-mail: [email protected] • Website: www.andreu.es Certificate No: 922a to LPS 1056: Issue 6 Product Name
Door Type
Max leaf Size Height (mm)
Max Leaf Size Width (mm)
Max Leaf Size Area (m2
Max Leaf Size Glass Type
TURIA EI2 60
Double leaf hinged doorset Double leaf hinged doorset Single leaf hinged doorset Single leaf hinged doorset Double leaf hinged doorset Double leaf hinged doorset Single leaf hinged doorset Single leaf hinged doorset Double leaf hinged doorset Double leaf hinged doorset Single leaf hinged doorset Single leaf hinged doorset
2710
2446
6.0
25mm thick Pyrobel
2710
2446
6.0
2710
1223
2710
TURIA EI2 90
TURIA EI2 120
Vision Panel Max Clear View Height (mm) 862
Vision Panel Max Clear View Width (mm) 756
Vision Panel Max Clear View Area 2 (m 0.59
Fire Resisitance (minutes) BS476: Part 22 Integrity / Insulation
Reliability (self closing Durability Ref LPS10560 Cause 3.6)
Cert. No.
60 / 30
No Performance Determined
922a/01
N/A
-
-
-
60 / 30
No Performance Determined
3.0
N/A
-
-
-
60 / 30
No Performance Determined
1223
3.0
25mm thick Pyrobel
862
756
0.59
60 / 30
No Performance Determined
2710
2446
6.0
53mm thick Pyrobel
862
728
0.57
90 / 60
No Performance Determined
2710
2446
6.0
N/A
-
-
-
90 / 60
No Performance Determined
2710
1223
3.0
53mm thick Pyrobel
862
728
0.57
90 / 60
No Performance Determined
2710
1223
3.0
N/A
-
-
-
90 / 60
No Performance Determined
2710
2446
6.0
53mm thick Pyrobel
862
728
0.57
120 / 90
No Performance Determined
2710
2446
6.0
N/A
-
-
-
120 / 90
No Performance Determined
2710
1223
3.0
53mm thick Pyrobel
862
728
0.57
120 / 90
No Performance Determined
2710
1223
3.0
N/A
-
-
-
120 / 90
No Performance Determined
922a/02
922a/03
Notes: 1. LPCB ref 922a/01, 922a/02 & 922a/03 Doorsets are approved when installed in concrete or masonry walls and must be fixed back to the supporting construction using four masonry anchors on each jamb.
20 Nov 2011
193
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS 2. LPCB ref 922a/01 & 922a/02 single leaf doorsets must be fitted with a Tesa model 50 lock, a Tesa model 2000N panic bar, a Tesa model 2000 door closer and 1 ½ pairs of steel butt hinges. Double leaf doorsets must be fitted with, on the active leaf, a Tesa model CF 50 lock and, on the inactive leaf, a Tesa model CF32 two-point latch; both leaves must be fitted with a Tesa model 4000N panic bar, a Tesa model GD2 door selector and 1 ½ pairs of steel butt hinges. In addition, one leaf must be fitted with a Tesa model CT2200 door closer and one with a Tesa model CT4000 door closer. 3. LPCB ref 922a/03 single leaf door sets must be fitted with a Tesa model CF50 lock, a Tesa model 2000N panic bar, a Telesco model Unik Combi door closer and 1 ½ pairs of steel butt hinges. Double leaf doorsets must be fitted with, on the active leaf a Tesa model CF 50 lock and the inactive leaf with a Tesa model CF32 two-point latch; both leaves must be fitted with a Tesa model 4000N panic bar, a Tesa model CT4000+S door closer/selector and 1 ½ pairs of steel butt hinges. 4. LPCB ref 922a/01, 922a/02 & 922a/03 The number of vision panels may be increased providing that the distance between the panes is no less than that between the tested pane and the edge of the leaf and that the size of the leaf cut out area is no greater than that of the tested doorsets. On this basis, the minimum distances between the backs of the frames of adjacent vision panels and the backs of the frames and the door leaf edge are 135mm for the TURIA EI2 60-minute doorsets and 147.5mm for the TURIA EI2 90minute and 120-minute doorsets, and the maximum total clear view area is 0.49m² (TURIA EI2 60-minute doorsets) and 0.47m² (TURIA EI2 90-minute and 120-minute doorsets).
Ascot Doors Limited Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800 E-mail: [email protected] • Website: www.ascotdoors.co.uk Certificate No: 131a to LPS 1056: Issue 5 Product Name
Spec.
Door Type
Max Height (m)
Max Width (m)
Max Area (m2 )
A200 Series A400 Series
4 4 4
Rolling shutter Single - leaf hinged Double - leaf hinged
7.00 2.42 2.42
7.00 1.02 2.04
49.00 2.24 4.48
Fire Resistance (min) BS 476: Part 22 Integrity 240 240 240
Fire Resistance (min) BS 476: Part 22 Insulation 0 0 0
Cert. No.
131a/01 131a/02 131a/03
Attenborough Doors Limited Merlin Way, Quarry Hill Industrial Estate, Ilkeston, Derbyshire DE7 4RA, United Kingdom Tel: +44 (0)115 9300815 • Fax: +44 (0)115 9448930 E-mail: [email protected] • Website: www.attenboroughdoor.co.uk Certificate No: 145b to LPS 1056: Issue 5 Product Name
Spec.
Door Type
Max Height (m)
Max Width (m)
Max Area (m2 )
Attenborough Fire Shutter
4
Rolling shutter
7.00
7.00
49.00
Fire Resistance (min) BS 476: Part 22 Integrity 240
Fire Resistance (min) BS 476: Part 22 Insulation 0
Cert. No.
145b/01
Clark Door Limited Unit F Central, Kingmoor Park, Carlisle, Cumbria CA6 4SJ, United Kingdom Tel: +44 (0)1228 522321 • Fax: +44 (0)1228 401854 E-mail: [email protected] • Website: www.clarkdoor.com Certificate No: 106a to LPS 1056: Issue 6
194
20 Nov 2011
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS Fireman Product Name
Door Type
Max Height (m)
Max Width (m)
Max Area (m2)
Fireman
Sliding door
4.0
4.0
Single leaf hinged door Double leaf hinged door
2.76 2.76
16.00
Fire Resistance (min) BS 476: Part 22 Integrity 240
Fire Resistance (min) BS 476: Part 22 Insulation 0
1.423
3.57
240
0
2.845
7.15
240
0
Reliability (self closing durability Ref. LPS 1056 Clause 3.6)
Cert. No.
No performance determined No performance determined No performance determined
106a/01 106a/02 106a/03
Notes: 1. Clark Door Ltd are also approved under LPS 1271 for installation of Fireman series of fire rated doorsets. 2. 106a/02 & 106a/03 - Vision panels, 6.5mm thick Pyroshield clear glass with maximum dimensions 1000mm wide x 1000mm high. Maximum area 1m² 3. 106a/03 - Double leaf doors, passive leaf must be fitted with a 3-point latching mechanism that engages in the top of frame, sill and the active leaf, and the active leaf must be fitted with a full length astragal that overlaps the passive leaf by at least 25mm. 4. 106a/01, 106a/02, & 106a/03 - Door leaf skins can be fabricated from galvanised mild steel or grade 316 stainless steel. 5. 106a/01, 106a/02, & 106a/03 - The doorsets can be installed in a rigid supporting construction such as brick, blockwork or concrete. The doorsets can also be installed in a composite wall panel system which provides equal or greater fire resistance than the doorset, when installed in a composite wall panel system the minimum fixing detail described in assessment report CC213834 shall be provided.
gte Brandschutz AG Hamburger Straße 2, D-14532 Stahnsdorf, Germany Tel: +49 3329 6359-0 • Fax: +49 3329 6359-25 E-mail: [email protected] • Website: www.gte.ag Certificate No: 735a to LPS 1056: Issue 5 excluding installation Fire Resistance (m) BS 476: Part 22 Insulation 90
Cert. No.
1.82
Fire Resistance (m) BS 476: Part 22 Integrity 90
1.4
1.82
90
90
735a/02
1.3
1.1
1.43
90
90
735a/03
0.85
1.1
0.935
90
90
735a/04
Product Name
Door Type
Max Height (m)
Max Width (m)
Max Area (m2)
CSS
Vertical sliding conveyor system shutter Horizontal sliding conveyor system shutter Flap type conveyor system shutter (Single) Flap type conveyor system shutter (Stacked)
1.3
1.4
1.3
735a/01
Notes: 1. LPCB Product Ref. No’s 735a/01, /02, /03 & /04 suitable for installation into masonry walls and Durasteel partitions as described in Assessment report No. CC221812. 2. CSS conveyor system shutters must be regularly maintained in line with the gte Brandschutz recommendations.
20 Nov 2011
195
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS
Hart Door Systems Redburn Road, Westerhope Industrial Estate, Westerhope, Newcastle upon Tyne NE5 1PJ, United Kingdom Tel: +44 (0)191 214 0404 • Fax: +44 (0)191 271 1611 E-mail: [email protected] • Website: www.speedor.com Certificate No: 016a to LPS 1056: Issue 5 excluding installation Product Name
Spec.
Door Type
Max Height (m)
Max Width (m)
Max Area (m2 )
Firebrand
4
Face-fixed rolling shutter
7.00
7.00
49.00
Fire Resistance (min) BS 476: Part 22 Integrity 240
Fire Resistance (min) BS 476: Part 22 Insulation 0
Cert. No.
016a/01
Note: 1. Hart Door Systems Ltd are also approved under LPS 1271 for installation of Firebrand rolling shutters.
Hörmann KG Freisen Bahnhofstrasse 43, D-66629 Freisen, Germany Tel: +49 (0)6855 993-0 • Fax: +49 (0)6855 993 197 E-mail: [email protected] • Website: www.hoermann.de Certificate No: Certificate No: 655a to LPS 1056: Issue 6 Product Name
Max clear opening sizes Max Height (mm)
Max clear opening sizes Max Width (mm)
Max clear opening sizes Max Area (m2
HBS 60 C1
2500
1250
3.125
HBS 60 C2 HBS 90 C1 HBS 90 C2 HBS 120 C-1 HBS 120 C-2 HBS 30 D1 HBS 60 D1 HBS 90 D1 HBS 30 F2 HBS 60 F2 HBS 90 F2
Vision panel Max Clear View Height (mm) 781
Vision panel Max Clear View Width (mm) 435
Vision panel Max Clear View Area (m2 0.34
Transom panel Option Available (see note 5) Yes
Fire resistance (min) BS476 Part 22 Integrity / Insulation 60 / 0
2500
2500
6.250
781
435
0.34
Yes
60 / 0
2500
1250
3.125
781
435
0.34
Yes
90 / 0
2500
2500
6.250
781
435
0.34
Yes
90 / 0
2500
1250
3.125
-
-
-
Yes
120 / 0
2500
2000
5.000
-
-
-
Yes
120 / 0
4225
1950
6.580
2085
1080
2.25
No
30 / 0
4062
1875
6.330
2085
1080
2.25
No
60 / 0
3770
1740
5.850
2085
1080
2.25
No
90 / 0
3700
3388
11.372
-
-
-
No
30 / 30
3700
3388
11.372
-
-
-
No
60 / 30
3458
3166
10.424
-
-
-
No
90 / 30
Reliability (self closing durability Ref. LPS1056 clause 3.6)
Cert. No.
No Performance determined
655a/07
No Performance determined No Performance determined No Performance determined No Performance determined No Performance determined No Performance determined No Performance determined No Performance determined No Performance determined No Performance determined No Performance determined
655a/08 655a/09 655a/10 655a/11 655a/12 655a/13 655a/14 655a/15 655a/16 655a/17 655a/18
Notes: 1. LPCB ref No. 655a/07 & 08 for alternative approved thin/thick rebated doorsets, frame profiles, sill arrangements & door furniture please refer to BRE assessment report CC 94538 Review 3. 2. LPCB ref No. 655a/09, 10, 11 & 12 for alternative approved thin/thick rebated doorsets, frame profiles, sill arrangements & door furniture please refer to BRE assessment report CC 92353 Review 3. 3. LPCB ref No. 655a/13, 14 & 15 doorsets are approved with the following hardware only. a. Hinges - 3 x Schwarte b. Locking mechanism - A BKS 6065 lock with an additional BKS6138 lock c. Door closer - Geze TS 4000 d. Door furniture - Eco Schulte 0432-EN 179-DO 20.3 plastic-coated steel lever handles, four dog bolts along the hinge edge.
196
20 Nov 2011
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS 4. LPCB ref No. 655a/16, 17 & 18 doorsets are approved with the following hardware only. a. Hinges - 2 pairs (4) Schwarte FH-615-20-KO on each leaf (passive/active leaf) b. Door closer - GEZE TS 4000 (active/passive leaf) c. Locking mechanism - BKS 6065 lock with additional BKS 6138 catch lock (active leaf), and BKS 1899 rebate locking bolt (passive leaf) d. Door furniture - ECO Shulte DIN 18273-FS-SG-BB-PZ lever handles (active/passive leaf) along with ECO Shulte SR Basis-1 door selector and three security bolts. 5. Where a doorset is fitted with a transom panel, the transom shall be up to a maximum height of 1000mm and not exceeding the maximum permitted height of the doorset, and be of the same construction as the door leaf which is fastened to the door frame with security bolts at the top and steel screws at the bottom at maximum 500mm centres. The transom panel may be fitted into the frame type either with or without flexible perimeter seals. For LPCB ref no 655a/07, 08, 09 & 10 a vision panel may be fitted within the transom panel in the same way as for the door leaf, see note 6. 6. LPCB ref No. 655a/07, 08, 09 & 10 Vision panel frames, steel channel spacers, minimum 1.0mm thick are welded to the leaf and connected together through the door leaf with M5 steel screws and threaded sockets at 250mm nominal centres. The frame depth which holds the 6.5mm-thick Georgian-wired glass is 15 mm. Ceramic fibre tape, nominally 4mm thick, is fitted between the glass and the frame. The single and double leaf doorsets may be fitted with one or more vision panels providing the following requirements are met a. Where more than one panel is fitted the max total vision area must not exceed 0.34m2 and each vision panel must be separated by at least 165mm b. The vision panel must be a minimum of 165mm from the leaf edge. c. The arrangement of the vision panels in double leaf doorsets shall be the same in both leaves 7. LPCB ref No. 655a/13, 14 & 15 Vision panel frames, comprising of 2mm-thick T-profiles, 30mm x 30mm, which are connected via 2mm fillet welds, the tail of the T-profiles are covered on both sides with strips of Promatect-L board, 30mm x 15mm. The vision panel Promaglas 90/35 Type 1.0 is held in place by a 2mm-thick steel glazing bead 44.5mm x 20.5mm fixed back to the glazing support frame with 4.2mm Ø x 50mm long self tapping screws. The perimeter on both sides is sealed against the glazing beads using EPDM seals. 8. LPCB ref No. 655a 07, 08, 09, 10,11 & 12 doorsets may be installed in either Masonry minimum 215mm-thick, Concrete/concrete block minimum 150mm-thick, autoclaved aerated concrete block walls minimum 215mm -thick / 400kg/m³ or Steel stud with plasterboard or calcium silicate board partitions. Where the doorset is installed in a plasterboard or calcium silicate board partition, the inside of the aperture to which the doorset is being fixed is lined with 2mm thick steel stud channel section, with flanges at least 40mm wide. The vertical studs either side of the aperture are fixed top and bottom to either a masonry or concrete supporting construction, and the horizontal stud along the top of the aperture is fixed to the vertical studs at either end. The door frame shall also be filled with fire resisting board and fixed to the partition using 5mm diameter self-tapping self-drilling screws. 9. LPCB ref No. 655a/13, 14, 15, 16, 17 & 18 doorsets may be installed in masonry or concrete walls minimum 240mm-thick.
Industrial Door Engineering Limited Winnington Avenue, Winnington, Northwich, Cheshire CW8 4EQ, United Kingdom Tel: +44 (0)1606 871832 • Fax: +44 (0)1606 871482 E-mail: [email protected] • Website: www.industrial-door-eng.co.uk Certificate No: 165a to LPS 1056: Issue 6 Product Name
Door Type
Max Height (m)
Max Width (m)
Max Area (m2) 49.0
Fire Resistance (min) BS 476: Part 22 Integrity 240
Fire Resistance (min) BS 476: Part 22 Insulation 0
Sentry
Rolling shutter
7.0
7.0
Sentry 2
Rolling shutter
7.0
7.0
49.0
120
0
Sentry 1 Compact
Rolling shutter
2.20
3.40
7.48
60
0
Sentry 1
Rolling shutter
2.20
2.20
4.84
60
0
Reliability (self closing Durability Ref LPS 1056 Clause 3.6) No performance determined No performance determined No performance determined No performance determined
Cert. No.
165a/01 165a/02 165a/03 165a/04
Notes:
20 Nov 2011
197
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS 1. LPCB Ref No. 165a/03 - Sentry 1 Compact rolling shutter can be fitted with either the flat or curved lath. 2. Industrial Door Engineering Limited are also Certified for the installation of fire rated Sentry rolling shutters against the requirements of LPS 1271.
J Durrance & Co Ltd Durrance House, 855 London Road, West Thurrock, Essex RM20 3LG, United Kingdom Tel: +44 (0)1708 258999 • Fax: +44 (0)1708 258900 E-mail: [email protected] • Website: www.jdurrance.co.uk Certificate No: 588a to LPS 1056: Issue 5 Product Name
Door Type
Max Height (m)
Max Width (m)
Max Area (m2)
PyroGuard 275
Rolling shutter
2.24
2.55
5.71
Fire Resistance (min) BS 476:Part 22 Integrity 120
Fire Resistance (min) BS 476:Part 22 Insulation -
Cert. No.
588a/01
L.B.S. Group (incorporating L.B.S Security Services Limited - t/a Specialized Door Services, Russell Shutters, Olsen Shutters and Ranford Doors) Unit 6, Sterling Trading Estate, Rainham Road South, Dagenham, Essex RM10 8TX, United Kingdom Tel: +44 (0)208 526 8572 • Fax: +44 (0)208 984 0378 Certificate No: 247b to LPS 1056: Issue 5
Fireguard Product Name
Door Type
Max Height (m)
Max Width (m)
Max Area (m2
Fireguard
Rolling shutter
7.0
10.0
49.0
Fire Resistance Integrity/Insulation (min) BS 476: Part 22 Integrity 240/0
Cert. No. 247b/01
Notes: 1. LPCB Ref 247b/01 - for a list of the component's and sizes for the shutter dimensions up to the maximum stated please refer to BRE Global assessment CC203994 Rev 2.
Lincs Doors Limited Innovation Way, Europarc, Grimsby, North East Lincolnshire DN37 9TT, United Kingdom Tel: +44 (0)1472 311057 • Fax: +44 (0)1472 311058 E-mail: [email protected] • Website: www.lincsdoors.co.uk Certificate No: 777a to LPS 1056: Issue 6
1.99
Fire Resistance (min) BS 476: Part 22 Integrity 120
Fire Resistance (min) BS 476: Part 22 Insulation 0
1.130
2.48
60
0
2.114
0.942
1.99
90
0
2.536
1.130
2.48
60
0
Product Name
Door Type
Max Height (m)
Max Width (m)
Max Area (m2
Pyroshield
Single leaf hinged without vision panel Single leaf hinged without vision panel Single leaf hinged with vision panel Single leaf hinged with vision panel
2.114
0.942
2.536
198
Reliability (self closing durability Ref. LPS 1056 Clause 3.6)
Cert. No.
No performance determined No performance determined No performance determined No performance determined
777a/01
777a/02
20 Nov 2011
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS Product Name
Door Type
Max Height (m)
Max Width (m)
Max Area (m2
3.98
Fire Resistance (min) BS 476: Part 22 Integrity 120
Fire Resistance (min) BS 476: Part 22 Insulation 0
Double leaf hinged without vision panel Double leaf hinged without vision panel Double leaf hinged with vision panel Double leaf hinged with vision panel
2.114
1.884
2.536
2.260
4.96
60
0
2.114
1.884
3.98
90
0
2.536
2.260
4.96
60
0
Reliability (self closing durability Ref. LPS 1056 Clause 3.6)
Cert. No.
No performance determined No performance determined No performance determined No performance determined
777a/03
777a/04
Notes: 1. Lincs Doors Ltd are also approved under LPS 1271 for installation of fire rated doorsets. 2. 777a/02 & 777a/04 - Vision panels, 10mm thick Pyrodur glass with maximum dimensions 245mm wide x 350mm high. 3. 777a/03 & 777a/04 - Double leaf doors, passive leaf must be fitted with a 3-point latching mechanism that engages in the top of frame, sill and the active leaf, and the active leaf must be fitted with a full length astragal that overlaps the passive leaf by at least 25mm. 4. 777a/01, 777a/02, 777a/03 & 777a/04 - Door leaf skins can be fabricated from galvanised mild steel or grade 316 stainless steel. 5. 777a/01, 777a/02, 777a/03 & 777a/04 - The doorsets can be installed in a rigid supporting construction such as brick, blockwork or concrete. The doorsets can also be installed in a composite wall panel system which provides equal or greater fire resistance than the doorset, when installed in a composite wall panel system the minimum fixing detail described in assessment report CC223023 shall be provided.
Mercian Shutters Limited Pearsall Drive, Brades Road Industrial Estate, Oldbury, West Midlands B69 2RA, United Kingdom Tel: +44 (0)121 544 6124 • Fax: +44 (0)121 552 6793 E-mail: [email protected] • Website: www.merciandoors.co.uk Certificate No: 355b to LPS 1056: Issue 5 excluding installation Product Name
Spec.
Door Type
Max Height (m)
Max Width (m)
Max Area (m2 )
SF Series
4
Rolling shutter Rolling shutter
7.00 5.00
7.00 10.0
49.00 50.00
Fire Resistance (min) BS 476: Part 22 Integrity 60, 120 & 240 60 & 120
Fire Resistance (min) BS 476: Part 22 Insulation 0 0
Cert. No.
355b/01
Notes: 1. SF series rolling shutters ref 355b/01 - Reference must be made to assessment report no CC242948 issue 2 dated 11 June 2008 to confirm component dimensions relevant to the system size and fire resistance required. 2. Mercian Shutters Ltd are also approved under LPS 1271 for installation of SF Series fire rated rolling shutters.
Middle East Insulation P O Box 14225, Dubai, United Arab Emirates Tel: +971 48801600 • Fax: +971 48801700 Website: [email protected] Certificate No: 708a to LPS 1056: Issue 6.1 Product Name
Maximum leaf size Height (mm)
Maximum leaf size Width (mm)
Maximum leaf size Area (m²)
Vision Panel Glass type
FORT/HC single leaf doorset
2967
1196
3.22
N/A
2968
1056
2.84
6mm Pyran S
20 Nov 2011
Vison panel Maximum clear view height (mm) -
Vision Panel Maximum clear view width (mm) -
Vision panel Maximum clear view area (m²) -
Transom Panel Option Available (see note 2) NO
BS 476: Part 22 Fire Resistance (minutes) Integrity 180
BS 476: Part 22 Fire Resistance (minutes) Insulation 0
500
200
Cert. No.
708a/01
0.10
YES
120
0
708a/03
199
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS Product Name
FORT/HC double leaf doorset
Maximum leaf size Height (mm)
Maximum leaf size Width (mm)
Maximum leaf size Area (m²)
Vision Panel Glass type
2968
1056
2.84
2968
1056
2.84
2968
1056
2.84
2968
1056
2.84
6mm Pyran S 6mm Pyroshield 6mm Pyroshield N/A
2337
1017
2.16
2337
1017
2.16
2337
1017
2.16
2337
1017
2.16
2337
1017
2.16
2682
1196
2682
Vison panel Maximum clear view height (mm) 805
Vision Panel Maximum clear view width (mm) 230
Vision panel Maximum clear view area (m²) 0.17
Transom Panel Option Available (see note 2) YES
BS 476: Part 22 Fire Resistance (minutes) Integrity 90
BS 476: Part 22 Fire Resistance (minutes) Insulation 0
700
200
805
230
0.14
YES
90
0
0.17
YES
60
0
-
-
-
YES
120
0
6mm Pyran S 6mm Pyran S 6mm Pyroshield 6mm Pyroshield N/A
700
200
0.14
YES
120
0
805
230
0.17
YES
90
0
700
200
0.14
YES
90
0
805
230
0.17
YES
60
0
-
-
-
YES
120
0
2.91
6mm Pyran S
254
254
0.065
YES
120
0
1196
2.91
700
200
0.140
YES
90
0
2682
1196
2.91
700
200
0.140
YES
90
0
2682
1196
2.91
6mm Pyran S 6mm Pyroshield 6mm Pyroshield
805
230
0.168
YES
60
0
Cert. No.
708a/05
708a/06
Notes: 1. LPCB Ref. 708a/03, 708a/05 & 708a/06 Where a doorset is fitted with a transom panel, the maximum height of the doorset, including transom panel, should not exceed 3000mm. The transom panel should be a maximum of 580mm high and have the same construction as the door leaves and be separated from them by a transom bar. The panel should be fastened to the door frame using 5mm Ø bolts via 25mm x 25mm x 60mm long x 2mm-thick clips. 2. LPCB Ref. 708a/01, 708a/03 & 708a/06 Doorset must be fitted with two pairs of hinges per leaf. 3. LPCB Ref. 708a/05 Doorset must be fitted with one-and-a-half pairs of hinges per leaf. 4. The approved doorsets have been tested or assessed for use with the following hardware types; a. Hinges - FORT stainless steel ball bearing hinges, McKinney butt hinges. Alternative mild steel, galvanised or stainless steel hinges with characteristics as detailed in assessment report CC 271427. b. Locking mechanism - Dorma 752F. Alternative locks and latches with characteristics as detailed in assessment report CC 271427. c. Door furniture - All door furniture shall be manufactured from steel or stainless steel as detailed in assessment report CC 271427. d. Door closer - Dorma 7601, Dorma TS72 or Geze TX4000 for use with single leaf doorsets, and Dorma TS72 for use with double leaf doorsets only. 5. LPCB Ref. 708a/01, 708a/03, 708a/05 & 708a/06 the doorsets listed have been tested in a brick wall surround and are therefore approved when installed in masonry or concrete wall surround only.
Saudi Factory For Fire Equipment Co. New Industrial Area, PO Box 58469, Riyadh 11515, Kingdom of Saudi Arabia Tel: +966 1 265 0070 • Fax: +966 1 265 2190 E-mail: [email protected] • Website: www.sffeco.com Certificate No: 403c to LPS 1056 Issue 6.1 Product Name
Door Type
Max Height (mm)
Max Width (mm)
Max Area (m²)
SFFECO FIRE DOOR
Single leaf, hinged steel doorset
2197
1092
2.399
Fire Resistance (minutes) BS 476: Part 22 Integrity 180
Fire Resistance (minutes) BS 476: Part 22 Insulation 0
Relibility (self closing durability Ref. LPS 1056 Clause 3.6) No Performance Determined
Cert. No.
403c/01
Notes. 1. LPCB Ref. No. 403c/01 The SFFECO FIRE DOOR doorset is approved to withstand a fire exposure from the opening side only, as detailed in BRE Assessment report CC225304.
200
20 Nov 2011
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS
Stobich Brandschutz GmbH Pracherstieg 6, D - 38644, Goslar, Germany Tel: 00 49 532 157080 • Fax: 00 49 532 157080 E-mail: [email protected] • Website: www.stobich.com Certificate No: 1064a to LPS 1056: Issue 6.1 Product Name
Supporting construction
Penetration sealing
ECClos-Q conveyor system closure
160mm thick Plasterboard partition (see note 1) 200mm blockwork wall (see note 4)
See note 2
See note 5 See note 6
Max leaf height (m) (note 3) 1.377
Max leaf width (m) (note 3) 1.940
Max leaf area (m) (note 3)
1.377
1.940
2.343
Fire Resistance (Min) BS EN 1366-7 Integrity/Insulation 120/120
1064a/01
2.343
240/120
1064a/02
Cert. No.
Notes: 1. LPCB Ref 1064a/01 - Standard flexible supporting construction according to BS EN 1366-7, table no 3, giving a fire resistance of 120 minutes, a cross bar type steel frame consisting of two uprights spanning from the floor to ceiling with a horizontal steel spanning between the sections (all 100mm x 100mm x 4mm thick) is located within the partition, around the structual opening to bear the load of the conveyor system. The conveyor system closure shall be face fixed and may be located on the exposed or unexposed side. 2. LPCB Ref 1064a/01 where the conveyor track penetrates the 160mm thick structural opening 1700mm (w) x 1500mm (h) a blockwork wall/panel is formed below (built from the finsihed floor level), minimum density 350kg/m3, 150mm thick, 800mm high and 2060mm wide, the top of the wall/panel is lined with a 20mm thick layer of Promatect-H board with the vertical edges protected with 100mm x 25mm x 3mm thick steel angles through fixed to the cross bar steel frame uprights (within the partition) at 200mm centres. A nominal 175mm opening is left around the conveyor track and blockwork wall/panel, this is built up with layers of Promatect-H25/H20/H15/H12 and H10, Promaseal-PL boards and Tenmat Firefly 102. Two 35mm lateral gaps are left between the boards and blockwork wall which are friction fitted with Rockwool type RPB9 minimum density 90kg/m3 to allow movement/expansion. 3. LPCB Ref 1064a/01 and 1064a/02 The closure leaf is 'T' shaped and may be increased by a maximum of 15% in height and/or 15% in width provided the surface area of the leaf is not increased by more than 20% from the dimensions given in the table above. The leaf may not be reduced by more than 50% in width and 75% in height. 4. LPCB Ref 1064a/02 - Standard low density rigid wall construction according to BS EN 1366-7, table no 2, with a minimum density of 613kg/m3. The conveyor system closure shall be face to face fixed and may be located on the exposed or unexposed side. 5. LPCB Ref 1064a/02 where the conveyor track penetrates the 200mm thick structural opening 1700mm (w) x 1500mm (h), a blockwork wall/panel is formed below minimum density 350kg/m3, 150mm thick and supported 300mm above the finished floor level with 4 x 300mm and 1 x 500mm L profile fixing brackets 150mm x 100mm x 10mm thick with threaded rods and nuts (M10). The top of the wall/panel is lined with a 20mm thick layer of Promatect-H board with the vertical edges protected with 100mm x 25mm x 3mm thick steel angles though fixed back to the 200mm thick wall at 200mm centres. A nominal 175mm opening is left around the conveyor track and blockwork wall/panel, this is built up with layers of Promatect-H25/H20/H15/H12 and H10, Promaseal-PL boards and Tenmat Firefly 102. Two 35mm lateral gaps are left between the boards and blockwork wall which are friction fitted with Rockwool type RPB9 minimum density 90kg/m3 to allow movement/expansion. 6. LPCB Ref 1064a/02 the penetration seal may incorporate a cable penetration, with maximum penetration size of 60mm x 220mm x 175mm (thickness x height x depth). The penetration must be lined with 20mm Promatect-H boards and the perimeter of the opening sealed with one layer of Tenmat Firefly 102, all control cables must then individually pass through a mineral wool batt (Rockwool RPB9 minimum density 90kg/m3) which is held in place within the penetration with EMPE glue.
Sunray Engineering Limited Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137 E-mail: [email protected] • Website: www.sunraydoors.co.uk Certificate No: 234b to LPS 1056: Issue 6.1
20 Nov 2011
201
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS Product Name
Spec.
Door Type
Max Height (m)
Max Width (m)
Max Area (m2)
ExcluDoor 4, 2 lock version
4
Single-leaf hinged door
2.25
1.05
2.40
Fire Resistance (min) BS 476: Part 22 Integrity 30
Fire Resistance (min) BS 476: Part 22 Insulation 0
Cert. No.
234b/01
Notes: 1. LPCB Ref: 234b/01 this product achieved an integrity rating of 120 minutes when tested opening towards the furnace with the deadlocks engaged. 2. LPCB Ref 234b/01 this product is also certificated to Security Rating 4 against the requirements of LPS 1175: Issue 5. 3. Sunray Engineering Ltd is also approved to LPS 1271 for installation of fire and security doors, see approval listing for details.
Certificate No: 234b to LPS 1056: Issue 6.1 Product Name
Door Type
Max leaf Height (m)
Max leaf Width (m)
Max leaf Area (m2)
ExcluDoor 4, Mk2 FR
Single-leaf hinged door Double-leaf hinged door Unequal width Double-leaf hinged door Single-leaf hinged door Double-leaf hinged door Unequal width Double-leaf hinged door
2.350
1.155
2.350
ExcluDoor 3, Mk3 FR
Cert. No.
2.71
Fire Resistance (min) BS EN 1634-1: 2008 Integrity/Insulation 240/0
1.155
5.42
240/0
234b/03
2.350
1.155
5.42
240/0
2.350
1.155
2.71
240/0
234b/04
2.350
1.155
5.42
240/0
234b/05
2.350
1.155
5.42
240/0
234b/02
Notes: 1. LPCB Ref: 234b/02, 234b/03, 234b/04 and 234b/05 doorsets may be fitted with a plain outer face so that there is no method of external access. 2. LPCB Ref: 234b/02, 234b/03, 264b/04 and 234b/05 these products are also certificated to Security Rating 4 against the requirements of LPS 1175: Issue 7. 3. Sunray Engineering Ltd is also approved to LPS 1271 for installation of fire and security doors, see approval listing for details. 4. LPCB Ref: 234b/02, 234b/03, 234b/04 and 234b/05 doorsets are approved with the following Surelock Slimline three-point lock system as shown below.
202
20 Nov 2011
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS Description
Code
Entry Key
3-point bolting
SL304
*
3-point bolting
SL305
*
3-point deadlocking 3 point
SL301
deadlocking
SL 303
3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking 3-point deadlocking
Access control
Exit Combination
Key
Turnknob
Access control
Panic
Emergency
SL310
SL311
SL313
SL314
SL315
SL320
*
SL321
*
SL322
*
SL323
*
SL324
*
SL325
*
SL330
SL335
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Certificate No: 450g to LPS 1056: Issue 6 Product Name
Door Type
Maximum Leaf Size Height (mm)
Maximum Leaf Size Width (mm)
Maximum Leaf Size (m2
Door Hardware Variations
Sentinel UltraSecure
DS1/LV Single leaf outward opening hinged doorset uninsulated
2200
940
2.06
SM3,SM4,SM6,SM7, SM8,SM10,SM13,SM14, SM16,SM17,SM18,SM20 SM23,SM24,SM26,SM27, SM28 & SM30.
20 Nov 2011
BS476: Part 22 Fire resistance (minutes) Integrity 240
BS476: Part 22 Fire resistance (minutes) Insulation 0
Cert. No.
450g/01
203
PART 2: SECTION 1.1 FIREBREAK DOORS AND SHUTTERS Product Name
Door Type
Maximum Leaf Size Height (mm)
Maximum Leaf Size Width (mm)
Maximum Leaf Size (m2
Door Hardware Variations
BS476: Part 22 Fire resistance (minutes) Integrity 120
BS476: Part 22 Fire resistance (minutes) Insulation 0
Cert. No.
DS1/LV Single leaf outward opening hinged doorset uninsulated DS2/LV Double leaf outward opening hinged doorset uninsulated DS2/LV Double leaf outward opening hinged doorset uninsulated
2640
1128
2.58
SM3,SM4,SM6,SM7, SM8,SM10,SM13,SM14, SM16,SM17,SM18,SM20 SM23,SM24,SM26,SM27, SM28 & SM30.
2768
1218
2.80
SM3,SM4,SM6,SM7, SM8,SM10,SM13,SM14, SM16,SM17,SM18,SM20 SM23,SM24,SM26,SM27, SM28 & SM30.
120
0
450g/02
2215
975
2.15
SM3,SM4,SM6,SM7, SM8,SM10,SM13,SM14, SM16,SM17,SM18,SM20 SM23,SM24,SM26,SM27, SM28 & SM30.
240
0
Notes: 1. The Sentinel UltraSecure Doorsets are also certified to Security Level 3 & 4 against the requirements of LPS1175: Issue 6. 2. LPCB ref 450g/01 & 450g/02, for approved Door Hardware Variations please refer to Manufacturer's Technical Literature. 3. LPCB ref 450g/01 & 450g/02, the Sentinel UltraSecure Doorsets are approved when installed in concrete/masonry walls or drywall partitions.
204
20 Nov 2011
PART 2: SECTION 1.2 LIFT LANDING DOORS
This section lists lift landing doors approved to LPS 1056 Test and Evaluation requirements for the LPCB Approval and Listing of Fire Doorsets, Lift Landing Doors and Shutter Assemblies. LPS 1056 is based upon relevant BS or European test criteria and not only looks at the fire integrity and insulation (where applicable) but also includes reliability cyclic tests and grading.
20 Nov 2011
205
PART 2: SECTION 2 FIRE AND SECURITY DOOR INSTALLERS
This section lists companies approved to LPS 1271 Requirements for LPCB Approval and Listing of Companies Installing Fire and Security Doorsets, Shutters and Smoke Barriers. This standard was developed to ensure that the product performance is not compromised by poor installation of the fire door or shutter. This section includes manufacturers installing doors and independent installation companies. Information regarding the security of doors is available in Part 4: Section 5.
Clark Door Limited Unit F Central, Kingmoor Park, Carlisle, Cumbria CA6 4SJ, United Kingdom Tel: +44 (0)1228 522321 • Fax: +44 (0)1228 401854 E-mail: [email protected] • Website: www.clarkdoor.com Certificate No. 106b to LPS 1271: Issue 1 Approved installer of Fireman series of fire rated doorsets.
Grange Door Systems Unit 12, Bilston Glen Industrial Estate, Edinburgh EH20 9LZ, United Kingdom Tel: +44 (0)131 440 7000 • Fax: +44 (0)131 440 7003 E-mail: [email protected] • Website: www.grangedoor.com Certificate No. 573b to LPS 1271: Issue 1 Approved installer of Kenrick Fire Stopper Face-fixed rolling shutter (LPCB Ref No 477a/01)
Hart Door Systems Redburn Road, Westerhope Industrial Estate, Westerhope, Newcastle upon Tyne NE5 1PJ, United Kingdom Tel: +44 (0)191 214 0404 • Fax: +44 (0)191 271 1611 E-mail: [email protected] • Website: www.speedor.com Certificate No. 016b to LPS 1271: Issue 1 Approved installer of Firebrand fire rated rolling shutters.
Industrial Door Engineering Limited Winnington Avenue, Winnington, Northwich, Cheshire CW8 4EQ, United Kingdom Tel: +44 (0)1606 871832 • Fax: +44 (0)1606 871482 E-mail: [email protected] • Website: www.industrial-door-eng.co.uk Certificate No. 165c to LPS 1271: Issue 1 Approved installer of Sentry, Sentry 1, Sentry 1 Compact and Sentry 2 fire rated rolling shutters.
Kone PLC Global House, Station Place, Chertsey, Surrey KT16 9HW, United Kingdom Tel: +44 (0)8451 999 999 • Fax: +44 (0)870 7701144 E-mail: [email protected] • Website: www.kone.co.uk Certificate No. 122P to LPS 1271: Issue 1 Installation of Certified fire rated Rolling Shutters, Hinged Doorsets and Lift Landing Sliding Folding Shutters
206
20 Nov 2011
PART 2: SECTION 2 FIRE AND SECURITY DOOR INSTALLERS KONE PLC Full UK Coverage Helpdesk KONE ONE Tel: +44 (0)8451 999 999 Fax: +44 (0)870 7701144 Email@ [email protected]
Mercian Shutters Limited Pearsall Drive, Brades Road Industrial Estate, Oldbury, West Midlands B69 2RA, United Kingdom Tel: +44 (0)121 544 6124 • Fax: +44 (0)121 552 6793 E-mail: [email protected] • Website: www.merciandoors.co.uk Also at: Mercian Industrial Doors (Southern) Limited, t/a Mercian Industrial Doors Southern, 10-12 Galleymead Road, Colnbrook, Slough, Berkshire SL3 0EN, United Kingdom Certificate No. 355c to LPS 1271: Issue 1 Approved installer of SF series of fire rated rolling shutters.
Prestige Fire Door Services Limited 15 Kings Road, Fleet, Hampshire GU51 3DJ, United Kingdom Tel: 01252 645534 • Fax: 01252 678742 E-mail: [email protected] • Website: www.prestigefiredoorservices.com Certificate No. 1066PI to LPS 1271: Issue 1 Approved Installer of certified fire doors and doorsets
Safe Partnership 3 East Street, Wareham, Dorset BH20 4NN, United Kingdom Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300 E-mail: [email protected] • Website: www.safepartnership.co.uk Certificate No. 835c to LPS 1271: Issue 1 Approved installer of Safe Partnership Ltd Safe Door timber security doors as approved under LPS 1175 (Ref Certificate 835a).
Sunray Engineering Limited Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137 E-mail: [email protected] • Website: www.sunraydoors.co.uk Certificate No. 234e to LPS 1271: Issue 1 Approved installer of certified Sunray Excludoor 3, Excludoor 3 MK 2 and Excludoor 4 (Ref product certificates 234b, 234c and 234d).
20 Nov 2011
207
PART 2: SECTION 3 SERVICE AND MAINTENANCE OF DOORS
This section lists companies approved to LPS 1197 Requirements for LPCB Approval and Listing of Companies Undertaking the Maintenance and Repair of Doorsets, Shutters, and Active Smoke/Fire Barriers. The effectiveness of a door is dependent upon regular inspection and servicing in accordance with the manufacturer’s recommendations. Companies approved to LPS 1197 have demonstrated their ability to carry out this work effectively. The listings include the geographical areas covered by the companies and the level of service provided. For the purposes of this document, the term fire door comprises any doorset or shutter assembly including any frame or guide, door leaf or leaves, rolling or folding curtain etc. which is designed to give a fire resisting capability when used for closing off permanent openings in separating elements of construction, including apertures for lift landing doors. This includes any side panels, vision panels or transom panels together with the door hardware and any seals (whether provided for the purpose of fire resistance and/or smoke control or for other purposes such as draught or acoustic reduction) which form the assembly.
Ascot Doors Limited Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800 E-mail: [email protected] • Website: www.ascotdoors.co.uk Certificate No. 131c to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of all of England, Scotland and Wales.
Bond Engineering (Maintenance) Ltd PO Box 7, North Road, Loughborough, Leicestershre LE11 1RL, United Kingdom Tel: 0844 5611 007 • Fax: +44 (0)1509 231638 E-mail: [email protected] • Website: www.bondengineeringuk.com Certificate No. 908a to LPS 1197: Issue 3 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of call in West Midlands, Staffordshire, Hereford, Worcester, Warwickshire, Milton Keynes, Northamptonshire, Peterborough, Lincolnshire, Nottinghamshire, Derbyshire, South Yorkshire and Leicestershire.
Crawford UK Limited Central & Southern UK 7 Churchill Way, 35A Business Park, Chapeltown, Sheffield, South Yorkshire S35 2PY, United Kingdom Tel: +44 (0)870 609 4474 • Fax: +44 (0)114 257 4397 E-mail: [email protected] • Website: www.crawfordsolutions.uk.com Certificate No. 001c to LPS 1197 General servicing/maintenance Maintenance contracts
208
Yes Yes
20 Nov 2011
PART 2: SECTION 3 SERVICE AND MAINTENANCE OF DOORS 24 hour answering service 24 hour emergency service
Yes Yes
Out of office hours: Tel: +44 (0)1244 355235.
Crawford UK Limited Northern UK First Floor, Cedar House, Quarrywood Court, Livingston, West Lothian EH54 6AX, United Kingdom Tel: +44 (0)1506 417237 • Fax: +44 (0)1506 412726 E-mail: [email protected] • Website: www.crawfordsolutions.uk.com Certificate No. 001c/02 to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
Out of office hours: Tel: +44 (0)1244 355235.
Grange Door Systems Unit 12, Bilston Glen Industrial Estate, Edinburgh EH20 9LZ, United Kingdom Tel: +44 (0)131 440 7000 • Fax: +44 (0)131 440 7003 E-mail: [email protected] • Website: www.grangedoor.com Certificate No. 573a to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of call in Scotland, Cumbria, North Lancashire, Teesside and Tyneside.
Industrial Door Engineering Limited Winnington Avenue, Winnington, Northwich, Cheshire CW8 4EQ, United Kingdom Tel: +44 (0)1606 871832 • Fax: +44 (0)1606 871482 E-mail: [email protected] • Website: www.industrial-door-eng.co.uk Certificate No. 165b to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of call in Cheshire, Clwyd, Derbyshire, Greater Manchester, Gwynedd, Lancashire, Merseyside and Yorkshire.
20 Nov 2011
209
PART 2: SECTION 3 SERVICE AND MAINTENANCE OF DOORS
Kone PLC Global House, Station Place, Chertsey, Surrey KT16 9HW, United Kingdom Tel: +44 (0)8451 999 999 • Fax: +44 (0)870 7701144 E-mail: [email protected] • Website: www.kone.co.uk Helpdesk KONE ONE KONE PLC, Global House, Station Place, Chertsey, Surrey KT16 9HW, United Kingdom Tel: +44 (0)8451 999 999 • Fax: +44(0)870 770 1144 E-mail: [email protected] • Website: www.kone.co.uk Certificate No. 122n to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
Onsite within 4 hours of call, Full UK Coverage
L.B.S. Group (incorporating L.B.S Security Services Limited - t/a Specialized Door Services, Russell Shutters, Olsen Shutters and Ranford Doors) Unit 6, Sterling Trading Estate, Rainham Road South, Dagenham, Essex RM10 8TX, United Kingdom Tel: +44 (0)208 526 8572 • Fax: +44 (0)208 984 0378 Certificate No. 247a to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of call-out in Bedfordshire, Berkshire, Buckinghamshire, Cambridgeshire, Essex, Hampshire, Hertfordshire, Kent, London, Norfolk, Northamptonshire, Oxfordshire, Suffolk, Surrey, East Sussex, West Sussex.
Mercian Shutters Limited Pearsall Drive, Brades Road Industrial Estate, Oldbury, West Midlands B69 2RA, United Kingdom Tel: +44 (0)121 544 6124 • Fax: +44 (0)121 552 6793 E-mail: [email protected] • Website: www.merciandoors.co.uk also at: Mercian Industrial Doors (Southern) Limited, t/a Mercian Industrial Doors Southern, 10-12 Gallymead Road, Colnbrook, Slough, Berkshire SL3 0EN, United Kingdom Certificate No. 355a to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of call in Hereford and Worcestershire, Shropshire, Staffordshire, Warwickshire and West Midlands.
210
20 Nov 2011
PART 2: SECTION 3 SERVICE AND MAINTENANCE OF DOORS
Safe Partnership 3 East Street, Wareham, Dorset BH20 4NN, United Kingdom Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300 E-mail: [email protected] • Website: www.safepartnership.co.uk Certificate No. 835b to LPS 1197: Issue 3 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes No Yes No
Scope: Area of cover, all regions of England, Wales and Northern Ireland. Maintenance and repair of Safe Partnership Ltd Safe Door timber security doors approved to LPS 1175 (Ref cert. 835a) only. Response service arising from perpetrators attempting or gaining entry into sanctuary or safe room based on agreed priority system.
Stanair Industrial Door Services Limited 2 Henson Way, Telford Way Industrial Estate, Kettering, Northamptonshire NN16 8PX, United Kingdom Tel: +44 (0)1536 482187 • Fax: +44 (0)1536 411799 E-mail: [email protected] • Website: www.stanair.co.uk Certificate No. 141a to LPS 1197- Issue 3 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of call in Bedfordshire, Buckinghamshire, Cambridgeshire, Leicestershire, Northamptonshire.
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL, United Kingdom Tel: +44 (0)161 205 2321 • Fax: +44 (0)161 455 4459 Website: www.tycofis.com Certificate No. 014c/01 to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
No (see note) Yes Yes Yes
On site within 4 hours of call in mainland UK. Note: General service/maintenance operated through Barnsley and Wigan offices.
20 Nov 2011
211
PART 2: SECTION 3 SERVICE AND MAINTENANCE OF DOORS
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) Albion Road, Carlton Industrial Estate, Barnsley S71 3HW, United Kingdom Tel: +44 (0)1226 702000 • Fax: +44 (0)1226 702001 Website: www.tycofis.com Certificate No. 014c/02 to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of call in mainland UK.
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) Unit 4, Bradley Hall Industrial Estate, Bradley Lane, Standish, Wigan WN6 0XQ, United Kingdom Tel: +44 (0)161 205 2321 • Fax: +44 (0)161 455 4459 Website: www.tycofis.com Certificate No. 014c/03 to LPS 1197 General servicing/maintenance Maintenance contracts 24 hour answering service 24 hour emergency service
Yes Yes Yes Yes
On site within 4 hours of call in mainland UK.
212
20 Nov 2011
Part 3 SMOKE AND FIRE VENTILATION SYSTEMS
PART 3: SMOKE AND FIRE VENTILATION SYSTEMS INTRODUCTION Fire ventilation systems are installed to: Keep escape and access routes free from smoke. Facilitate fire fighting operations by creating a smoke free layer. Delay and/or prevent flashover and the subsequent full development of the fire. Protect equipment, furnishings, contents, etc. Reduce the thermal effects on structural components during a fire. Reduce damage caused by thermal decomposition of products and hot gases. The key components of smoke and fire ventilation systems, i.e. fire dampers, ductwork, smoke curtains and powered smoke and heat exhaust ventilation fans, are listed in this section. Their functions are: Fire dampers: To maintain compartmentation where air distribution ducts pass through compartment walls and floors. LPCB approves fire dampers to LPS 1162: Requirements for the approval of fire dampers. Fire resistant ductwork: To maintain compartmentation when air distribution ducts pass through compartment walls and floors and where fire resisting dampers are not used to provide the compartmentation. To achieve the same fire resistance in terms of integrity and, if required, insulation as required for the compartment walls or floors. LPCB approves fire resistant ductwork to BS 476: Part 24 Fire tests on building materials and structures: Method for determination of the fire resistance of ventilation ducts. Smoke curtains: To create a smoke reservoir by containing and limiting the travel of smoke. To channel smoke in a predetermined direction. To prevent or retard smoke entry to another area or void. LPCB approves Smoke curtains to LPS 1182: Requirements for the approval of fixed fabric smoke curtains, fixed metal smoke curtains and powered smoke curtains. Powered smoke and heat exhaust ventilation fans: To channel heat and smoke in a predetermined direction. To prevent smoke logging of the protected space. Powered smoke and heat exhaust ventilation fans are approved in accordance with BS EN 12101-3 Smoke and heat control systems. Part 3 Specification for powered smoke and heat exhaust ventilation. Grease filters used in commercial kitchen extract systems: To reduce flammable and volatile grease droplets from the cooking exhaust of commercial cooking equipment. LPCB categorises and approves grease filters in accordance with the requirements of LPS 1263: Requirements for the approval and listing of the fire performance of grease filters used in commercial kitchen extract systems.
214
20 Nov 2011
PART 3: SECTION 1 FIRE DAMPERS
Fire dampers are installed: To maintain compartmentation where air distribution ducts pass through compartment walls and floors. To achieve the same fire resistance in terms of integrity as required for compartment walls or floors. To close completely as soon as a fire is detected.
All the fire resistant dampers listed in Section 1 of this part of the list have been tested and assessed against the requirements of LPS 1162 Requirements and tests for the LPCB approval of fire dampers.
Actionair Ruskin Air Management, Joseph Wilson Industrial Estate, South Street, Whitstable, Kent CT5 3DU, United Kingdom Tel: +44 (0)1227 276100 • Fax: +44 (0)1227 264262 E-mail: [email protected] • Website: www.actionair.co.uk Certificate No: 017a to LPS 1162: Issue 4 Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation / Construction
Fire Shield
I/F damper horizontally mounted
1250
1000
-
I/F damper vertically mounted
1250
1000
-
I/F damper vertically mounted
1250
1000
-
Concrete Floor. Ref - AA10701 Mounted using a HEVAC/HVCA frame in a 150mm thick reinforced aerated concrete floor. Builders ties located at 500mm centres around the frame, are bent outwards and wired to 10mm- diameter stud anchors driven into the reveal the 15 - 60mm gap between the frame and reveal is filled with mortar or concrete. Masonry/concrete Wall. Ref - AA/F10703 Mounted using a HEVAC/HVCA frame in a 150mm thick masonry/concrete wall. Builders ties located at 400mm centres around the frame, 15 - 60mm gap between the frame and reveal. The ties are bent outwards and mortared into 50mm-deep pockets cut into the wall. Masonry/concrete Wall. Ref - AA/F10703 Mounted using a HEVAC/HVCA frame in a 150mm thick masonry/concrete wall. Builders ties located at 400mm centres around the frame, 15 - 60mm gap between the frame and reveal. The ties are bent outward and mortared into the gap
20 Nov 2011
BS EN 1366-2 Fire Performance (min) Integrity / Insulation / Leakage 240 / 0 / 0
LPS 1162 Class (Note 1)
Cert. No.
Standard
017a/01
240 / 0 / 0
Standard
120 / 0 / 0
Standard
215
PART 3: SECTION 1 FIRE DAMPERS Product Name
216
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation / Construction
DWFX-F damper vertically mounted
1250
1000
-
+ Flange damper vertically mounted
1250
1000
-
DWFX-C damper vertically mounted
1250
1000
-
S&A damper vertically mounted
1250
1000
-
Drywall Partition. Ref - AA/F10705 Mounted using 2 x 10mm Ø threaded drop rods attached to the damper via steel cleats welded to the top corners of the DWFX-F Flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a steel stud partition 120mm to 200mm thick. (see note 3) Masonry/concrete Wall. Ref - AA/F10707REV2 mounted in a masonry/concrete wall minimum 150mm thick, the Flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing is fixed to the face of the wall the gap (25mm max) between the aperture and damper casing is filled with Rockwool and held in place with an angle flange to the inside of the reveal or Z flange to the face of the wall. Drywall Partition. Ref - AA/F10709 mounted using 2 x 10mm Ø threaded steel drop rods attached to angle section cleats welded to the top sides of the damper casing in a plasterboard partition min 100mm max 200mm (see note 4) Drywall Partition. Ref - AA/F10711 Infill up to 675mm mounted using 2 x 10mm Ø threaded steel drop rods to the damper via steel cleats welded to a flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a Rockwool Ablative Coated Batt within a plaster board partition 100mm thick (see notes 5 and 6)
BS EN 1366-2 Fire Performance (min) Integrity / Insulation / Leakage 120 / 0 / 0
Standard
120 / 0 / 0
Standard
120 / 0 / 0
Standard
120 / 0 / 0
Standard
LPS 1162 Class (Note 1)
Cert. No.
20 Nov 2011
PART 3: SECTION 1 FIRE DAMPERS Product Name
Smoke Shield PTC
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation / Construction
S&A damper vertically mounted
1250
1000
-
S&A damper vertically mounted
1250
1000
-
S&A damper vertically mounted
1250
1000
-
I/F damper horizontally mounted
1000
1000
-
Masonry/concrete Wall. Ref - AA/F10713 Infill up to 675mm mounted using 2 x 10mm Ø threaded steel drop rods to the damper via steel cleats welded to a flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a Rockwool Ablative Coated Batt within a masonry/concrete wall (see note 6) Drywall Partition. Ref - AA/F10715 mounted using 2 x 100mm Ø threaded steel drop rods to a flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a plasterboard partition Stone mineral wool (60 100kg/m³) is fitted around the damper on the opposite face to the flange, prior to a steel installation angle being riveted to the duct. (see note 7) Masonry/concrete Wall. Ref - AA/F10717 mounted using 2 x 10mm Ø threaded steel cleats welded to a flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a masonry / concrete wall. Stone mineral wool (80 100kg/m³) is fitted around the damper on the opposite face to the flange, prior to a steel installation angle being riveted to the duct. Concrete Floor. Ref - AA/F10700 Mounted using a HEVAC/HVCA frame in a 150mm thick reinforced aerated concrete floor. Builders ties located at 500mm centres around the frame, are bent outwards and wired to 10mm- diameter stud anchors driven into the reveal the 15 - 60mm gap between the frame and reveal is filled with mortar or concrete.
20 Nov 2011
BS EN 1366-2 Fire Performance (min) Integrity / Insulation / Leakage 120 / 0 / 0
Standard
120 / 0 / 0
Standard
120 / 0 / 0
Standard
240 / 0 / 120
Standard
LPS 1162 Class (Note 1)
Cert. No.
017a/04
217
PART 3: SECTION 1 FIRE DAMPERS Product Name
218
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation / Construction
I/F damper vertically mounted
1000
1000
-
I/F damper vertically mounted
1000
1000
-
DWFX-F damper vertically mounted
1000
1000
-
+ Flange damper vertically mounted
1000
1000
-
Masonry/concrete Wall. Ref - AA/F10702 Mounted using a HEVAC/HVCA frame in a 150mm thick masonry/concrete wall. Builders ties located at 400mm centres around the frame. 15 - 60mm gap between the frame and reveal. The ties are bent outwards and mortared into 50mm-deep pockets cut into the wall. Masonry/concrete Wall. Ref - AA/F10702 Mounted using a HEVAC/HVCA frame in a 150mm thick masonry/concrete wall. Builders ties located at 400mm centres around the frame. 15 - 60mm gap between the frame and reveal the ties are bent outwards and mortared into the gap Drywall Partition. Ref - AA/F10704 Mounted using 2 x 10mm Ø threaded drop rods attached to the damper via steel cleats welded to the top corners of the DWFX-F Flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a steel stud partition 120mm to 200mm thick. (see note 3) Masonry/concrete Wall. Ref - AA/F10706REV 2 mounted in a masonry / concrete wall minimum 150mm thick, the Flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing is fixed to the face of the wall the gap (25mm max) between the aperture and damper casing is filled with Rockwool and held in place with an angle flange to the inside of the reveal or Z flange to the face of the wall.
BS EN 1366-2 Fire Performance (min) Integrity / Insulation / Leakage 240 / 0 / 120
Standard
120 / 0 / 120
Standard
120 / 0 / 120
Standard
120 / 0 / 120
Standard
LPS 1162 Class (Note 1)
Cert. No.
20 Nov 2011
PART 3: SECTION 1 FIRE DAMPERS Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation / Construction
DWFX-C
1000
1000
-
S&A damper vertically mounted
1000
1000
-
S&A damper vertically mounted
1000
1000
-
S&A damper vertically mounted
1000
1000
-
Drywall Partition. Ref - AA/F10708 mounted using 2 x 10mm Ø threaded steel drop rods attached to angle section cleats welded to the top sides of the damper casing in a plasterboard partition min 100mm max 200mm. (see note 4) Drywall Partition. Ref - AA/F10710 Infill up to 675mm mounted using 2 x 10mm Ø threaded steel drop rods to the damper via steel cleats welded to a flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a Rockwool Ablative Coated Batt within a plaster board partition 100mm thick. (see notes 5 and 6) Masonry/concrete Wall. Ref - AA/F10712 Infill up to 675mm mounted using 2 x 10mm Ø threaded steel drop rods to the damper via steel cleats welded to a flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a Rockwool Ablative Coated Batt within a masonry/concrete wall (see note 6) Drywall Partition Ref - AA/F10714 mounted using 2 x 10mm Ø threaded steel drop rods to the damper via steel cleats welded to a flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in plasterboard partition. Stone mineral wool ( 60 - 10kg/m³ is fitted around the damper on the opposite face to the flange, prior to a steel installation angle being riveted. to the duct (see note 7)
20 Nov 2011
BS EN 1366-2 Fire Performance (min) Integrity / Insulation / Leakage 120 / 0 / 120
Standard
120 / 0 / 120
Standard
120 / 0 / 120
Standard
120 / 0 / 120
Standard
LPS 1162 Class (Note 1)
Cert. No.
219
PART 3: SECTION 1 FIRE DAMPERS Product Name
CSS Circular Smoke Shield
220
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation / Construction
S&A damper vertically mounted
1000
1000
-
Damper Horizontally Mounted
-
-
355
Masonry/concrete Wall. Ref - AA/F10716 mounted using 2 x 10mm Ø threaded steel drop rods to the damper via steel cleats welded to a flange (75mm wide x 1.2mm thick) which is tack welded to the damper casing in a masonry / concrete wall. Stone mineral wool (60 100kg/m³) is fitted around the damper on the opposite face to the flange, prior to a steel installation angle being riveted to the duct. Concrete Floor. Ref - AA/F10719 mounted in a concrete floor min 100mm thick using a square flange/frame (two sections) and assembled in situ using M5 tapit screws where the sections overlap each other. The flange on the upper surface is fixed using drywall screws, corner voids around the damper casing within the thickness of the floor are packed with compressed stone wool (nominal density 28 kg/m³) prior to fixing the lower installation frame, which is fixed in a similar manner using HA50 Loden anchors. The nominal gap between the edge of the aperture and the damper casing should be 5mm.
BS EN 1366-2 Fire Performance (min) Integrity / Insulation / Leakage 120 / 0 / 120
Standard
120 / 0 / 120
Standard
LPS 1162 Class (Note 1)
Cert. No.
017a/05
20 Nov 2011
PART 3: SECTION 1 FIRE DAMPERS Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation / Construction
Damper vertically installed
-
-
355
Damper vertically installed
-
-
355
Drywall Partition. Ref - AA/F10718 mounted in a plasterboard partition (min 100mm max 200mm) using a square flange/frame (two sections) and assemble in situ using M5 tapit screws where the sections overlap each other. The flanges are fixed to the stud and track sections around the perimeter of the aperture using drywall screws, corner voids around the damper casing within the thickness of the aperture are packed with compressed stone wool (nominal density 35kg/m³). The nominal gap between the edge of the aperture and the damper casing should be 5mm. (see note 8) Masonry/concrete Wall. Ref - AA/F10720 mounted in a masonry / concrete wall (min 100mm thick) using a square flange/frame (two sections) and assembled in situ using M5 tapit screws where the sections overlap each other. The flanges are fixed to the wall around the parameter of the aperture using M5 steel anchors, corner voids around the damper casing within the thickness of the aperture are tacked with compressed stone wool (nominal density 35kg/m³). The nominal gap between the edge of the aperture and the damper casing should be 5mm.
20 Nov 2011
BS EN 1366-2 Fire Performance (min) Integrity / Insulation / Leakage 120 / 0 / 120
Standard
120 / 0 / 120
Standard
LPS 1162 Class (Note 1)
Cert. No.
221
PART 3: SECTION 1 FIRE DAMPERS Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation / Construction
CCS Circular Smoke Shield
Damper vertically installed
-
-
355
CSS Circular Smoke Shield
Damper vertically installed
-
-
355
Drywall Partition. Ref - AA/F10721 Infill up to 675mm mounted using 2 x 10mm Ø threaded steel drop rods to the damper via steel cleats welded to a flange which is a square flange/frame (two sections) and assembled in situ using M5 tapit screws where the sections overlap each other in a Rockwool Ablative Coated Batt within a plaster board partition 100mm thick. (See notes 9 and 10) Masonry/concrete Wall. Ref - AA/F10722 Infill up to 875mm mounted using 2 x 10mm Ø threaded steel drop rods to the damper via steel cleats welded to a flange which is a square flange/frame (two sections) and assemble in situ using M5 tapit screws where the sections overlap each other in Rockwool Ablative Coated Batt within a masonry / concrete wall. (see note 10)
BS EN 1366-2 Fire Performance (min) Integrity / Insulation / Leakage 120 / 0 / 120
Standard
120 / 0 / 120
Standard
LPS 1162 Class (Note 1)
Cert. No.
Notes; 1. See LPS1162 Issue 4, Table 1. 2. LPCB ref 017a/"01 and 017a/04 damper casing and blades are manufactured from Stainless steel with the casing manufactured from galvanised steel. LPCB ref 017a/05 damper casing and blades are manufactured from galvanised steel. 3. The partition comprised a steel framework of steel studs insulated with a layer of Rockwool RW5 (minimum density 100kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture framed using stud and track with the web of the section set flush with the cut edges of the board, the framed aperture was then lined with one layer of 12.5mm-thick Type F plasterboard. The gap between the perimeter of the damper casing and the sides of the aperture should be no greater than 15mm wide along the top, bottom and non drive side, 40mm along the drive side. The gap is packed with Rockwool RW5 stone mineral wool and covered with a Type F plasterboard pattress overlapping the edge of the partition by minimum 65mm. 4. The partition comprised a steel framework of steel studs insulated with a layer of Rocksilk RS33 (minimum density 33kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture framed using stud and track with the web of the section set flush with the cut edges of the board, the framed aperture was then lined with one layer of 12.5mm-thick Type F plasterboard. The gap between the vertical sides of the damper casing and the sides of the aperture should be no greater than 50mm wide. The gap is packed with stone mineral wool (minimum density 33kg/m³) the top and bottom of the damper casing fits flush with the aperture and is sealed with a bead of intumescent mastic to each side. A Type F plasterboard pattress overlapping the edge of the partition by minimum 75mm is then fixed to both sides of the partition. 5. The partition comprised a steel framework of steel studs insulated with a layer of Rockwool RW3 (minimum density 60kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture framed using stud and track with the web of the section set flush with the cut edges of the board, the framed aperture was then lined with two layers of 12.5mm-thick Type F plasterboard. 6. The Ablative Coated Batt is constructed by fitting the batt in the aperture with the longest edges orientated horizontally. The batts are glued into the opening and to each other using FirePro glue. The interface between the batts and the supporting construction is sealed with a 15mm bead of acoustic intumescent sealant. Following installation of the batts, a coat of Rockwool Ablative coating is applied over both sides of the completed seal. The batts should be cut to size so that they fit against the damper casing on all four sides and they rest against the flange which is tack welded to one face of the
222
20 Nov 2011
PART 3: SECTION 1 FIRE DAMPERS
7.
8.
9.
10.
damper casing. A 20mm-thick pattress of Rockwool Ablative Coated batt is fitted around the damper on the opposite face to the flange, prior to a steel installation angle being riveted to the duct. The partition comprised a steel framework of steel studs insulated with a layer of Rockwool RW5 (minimum density 100kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture framed using stud and track with the web of the section set flush with the cut edges of the board, the framed aperture was then lined with one layer of 12.5mm-thick Type F plasterboard. Stone mineral wool (60 - 100kg/m³) is fitted around the damper on the opposite face to the flange, prior to a steel installation angle being riveted to the duct. The partition comprised a steel framework of steel studs insulated with a layer of Stone mineral wool (minimum density 38kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture framed using stud and track with the web of the section set flush with the cut edges of the board, the framed aperture was then lined with one layer of 12.5mm-thick Type F plasterboard. The partition comprised a steel framework of steel studs insulated with a layer of Stone mineral wool (minimum density 100kg/m³) insulation slab and clad on each face with two layers of 12.5mm-thick Type F plasterboard. With the aperture framed using stud and track with the web of the section set flush with the cut edges of the board, the framed aperture was then lined with two layers of 12.5mm-thick Type F plasterboard. The Ablative Coated Batt is constructed by fitting the batt in the aperture with the longest edges orientated horizontally. The batts are glued into the opening and to each other using FirePro glue. The interface between the batts and the supporting construction is sealed with a 15mm bead of acoustic intumescent sealant. Following installation of the batts, a coat of Rockwool Ablative coating is applied over both sides of the completed seal.
Advanced Air (UK) Limited PO Box 153, Burrell Way, Thetford IP24 3QU, United Kingdom Tel: +44 (0)1842 765657 • Fax: +44 (0)1842 753493 E-mail: [email protected] • Website: www.advancedair.co.uk Certificate No: 128a to LPS 1162: Issue 3 Max Duct Size: Width 1000
Max Duct Size: Diameter
ISO 10294-15
0100
Max Duct Size: Height 1000
1000
E240
0100
1000
1000
1000
E240
0200
1000
1000
1000
E240
Product Name
Series
Curtain Fire Damper
Fire Smoke Control Damper
Insulated Fire Damper
0200
1000
1000
1000
E240
1240
1000
1000
1000
E120
1240
1000
1000
1000
E120
1250
1000
1000
1000
E120
1250
1000
1000
1000
E120
1260
1000
1000
1000
E120
1260
1000
1000
1000
E120
1270
1000
1000
1000
E120
1270
1000
1000
1000
E120
2400
1000
1000
1000
ES210/ESI205
2400
1000
1000
1000
ES210
Fire Resistance Integrity (min) Vertical plane 240
Fire Resistance Insulation (min)
Horizontal plane 240 Vertical plane 240 Horizontal plane 240 Vertical plane 120 Horizontal plane 120 Vertical plane 120 Horizontal plane 120 Vertical plane 120 Horizontal plane 120 Vertical plane 120 Horizontal plane 120 Vertical plane 210 Horizontal plane 250
205
Durability Standard2
Corrosion Marine3
Tests Cyclic4
Cert. No.
Satisfactory
Not tested
Not tested
128a/01
Satisfactory
Not tested
Not tested
Satisfactory
Not tested
Not tested
Satisfactory
Not tested
Not tested
Satisfactory
Not tested
Not tested
Satisfactory
Not tested
Not tested
Satisfactory
Not tested
Not tested
128a/02
128a/03
250
Notes: 1. 2. 3. 4.
Standard LPS 1162 requirements for normal use, vertical plane. Corrosion test Appendix B LPS 1162 for marine use. Cyclic test Appendix A LPS 1162 for repeated use. LPS 1162 incorporates the requirements of ISO 10294-1
20 Nov 2011
223
PART 3: SECTION 1 FIRE DAMPERS
Arabian Thermal Aire Industries Company Ltd Al-Jubail Industrial City, Tareeg # 118, Al-Sinaiyah-31961, Kingdom of Saudi Arabia Tel: +966 3 341 5857 E-mail: [email protected] • Website: www.ataico.com Certificate No: 699a to LPS 1162: Issue 3 Product Name
Max Duct Size: width (mm) 1250
Max Duct size: diameter (mm) -
ISO 10294
Fire Resistance Integrity (min)2
Fire Resistance Insulation (min)
Durability Standard1
Corrosion Marine
Test Cyclic
Cert. No.
WFA
Max Duct Size: height (mm) 1000
-
Satisfactory
Not tested
1000
-
-
-
Satisfactory
Not tested
Not tested Not tested
699a/01
1000
Horizontal plane - 240 Horizontal plane - 240
-
WGDB
Series
ATAI-Waterloo galvanized steel shutter ATAI-Waterloo galvanized steel smoke/fire damper
699a/02
Notes: 1. Standard LPS1162 requirement for normal use. 2. Mounted in a steel deck assembly.
BSB Engineering Services Limited Unit E, Tribune Drive, Trinity Trading Estate, Sittingbourne, Kent ME10 2PD, United Kingdom Tel: +44 (0)1795 422609 • Fax: +44 (0)1795 429543 E-mail: [email protected] • Website: www.bsb-dampers.co.uk Certificate No: 828a to LPS 1162: Issue 4 Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation/Construction
FSD-TD
S, C & O / Horizontal plane HF
1200
1200
1200
S, C & O / Vertical plane HF
1000
1000
1000
S, C & O / Vertical plane SA
1000
1000
1000
Ref FSD-TD M1-r4 Mounted using a HEVAC/HVAC frame in a 200mm-thick reinforced aerated concrete floor of minimum nominal density 580kg/m 3 Ref. FSD-TD M2-r4 Mounted using HEVAC/HVAC frame into an aperture in minimum 150mm-thick lightweight aerated block wall of minimum nominal density 650kg/m 3 Ref FSD-TD M3-r4 Mounted using a sleeve & angles method in a min 100mm max 200mm thick blockwork wall of minimum nominal density 650kg/m 3 (See Note 5)
224
BS EN 1366-2 Fire performance (min) Integrity/ Insulation/ Leakage 240 / 0 / 240
LPS 1162 Class (Note 1)
Cert. No.
Standard
828a/03
240 / 0 / 240
Standard
120 / 0 / 120
Standard
20 Nov 2011
PART 3: SECTION 1 FIRE DAMPERS Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation/Construction
S, C & O / Vertical plane BF
1000
1000
1000
Infill up to 600mm Ref FSD-TD M4A-r4 Mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition.
S, C & O / Vertical plane BF
1000
1000
1000
BS EN 1366-2 Fire performance (min) Integrity/ Insulation/ Leakage 120 / 0 / 120
Standard
Infill greater than 600mm Ref FSD-TD M4B-r4 mounted using 2x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition.
120 / 0 / 120
Standard
LPS 1162 Class (Note 1)
Cert. No.
(See Note 6)
(See Note 6 & 7)
S, C & O / Vertical plane SA
1000
1000
1000
Ref FSD-TD M5-r5 mounted using a sleeve and angles method in a min 100mm max 200mm thick steel stud partition.
120 / 0 / 120
Standard
S, C & O / Vertical plane CL
1000
1000
1000
Ref FSD-TD M6-r4 Mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a steel stud partition within an opening in a masonry wall minimum 100mm thick & of minimum nominal density 650kg/m3.
120 / 0 / 120
Standard
S, C & O / Vertical plane BF
1000
1000
1000
Infill up to 600mm Ref.FSD-TD M7A-r4 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition within an opening in a steel stud partition minimum 140mm thick.
120 / 0 / 120
Standard
(See Note 8)
(See Note 8)
(See Note 6 & 8)
20 Nov 2011
225
PART 3: SECTION 1 FIRE DAMPERS Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation/Construction
FSDTD
S, C & O / Vertical plane BF
1000
1000
1000
Infill greater than 600mm Ref. FSD-TD M7B-r4 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition within an opening in a steel stud partition minimum 140mm thick.
FSD-TD
S, C & O / Vertical plane BF
1000
1000
1000
BS EN 1366-2 Fire performance (min) Integrity/ Insulation/ Leakage 120 / 0 / 120
Standard
Infill greater than 600mm Ref FSD-TD M8-r5 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition within an opening in a masonry wall minimum 100mm thick & of minimum nominal density 650kg/m3.
120 / 0 / 120
Standard
Ref. FSD-TD M9-r5 mounted using an angle frame in a min 100mm max 200mm thick steel stud partition.
120 / 0 / 120
Standard
LPS 1162 Class (Note 1)
Cert. No.
(See Note 6, 7 & 8)
(See Note 6 & 7)
S, C & O / Vertical plane AF
1200
1200
1200
(See Note 9)
FD
226
A, B, I, C & O / Vertical plane HF
1200
1000
1000
Ref FD M1-r1 mounted using a HEVAC/HVAC frame in a minimum 150mm-thick reinforced aerated concrete floor of minimum nominal density 580kg/m 3.
240 / 0 / 0
Standard
A, B, I, C & O / Vertical plane HF
1200
1000
1000
240 / 0 / 0
Standard
A, B, I, C & O / Vertical plane SA
1200
1000
1000
Ref FD M2-r1 mounted using HEVAC/HVAC frame into an aperture in minimum 150mm-thick lightweight aerated block wall of minimum nominal density 650kg/m 3. Ref FD M3-r1 mounted using a sleeve & angles method in a min 100mm max 200mm thick blockwork wall of minimum nominal density 650kg/m 3. (See Note 5)
120 / 0 / 0
Standard
828a/04
20 Nov 2011
PART 3: SECTION 1 FIRE DAMPERS Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation/Construction
A, B, I, C & O / Vertical plane BF
1200
1000
1000
Infill up to 600mm Ref FD M4A-r1 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition.
A, B, I, C & O / Vertical plane BF
1200
1000
1000
BS EN 1366-2 Fire performance (min) Integrity/ Insulation/ Leakage 120 / 0 / 0
Standard
Infill greater than 600mm Ref FD M4B-r1 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition.
120 / 0 / 0
Standard
LPS 1162 Class (Note 1)
Cert. No.
(See Note 6)
(See Note 6 & 7)
A, B, I, C & O / Vertical plane SA
1200
1000
1000
Ref FD M5-r1 mounted using a sleeve and angles method in a min 100mmmax 200mm thick steel stud partition.
120 / 0 / 0
Standard
A, B, I, C & O / Vertical plane CL
1200
1000
1000
Ref FD M6-r1 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a steel stud partition within an opening in a masonry wall minimum 100mm thick & of minimum nominal density 650kg/m3.
120 / 0 / 0
Standard
A, B, I, C & O / Vertical plane BF
1200
1000
1000
Infill up to 600mm Ref FD M7A-r1 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition within an opening in a steel stud partition minimum 140mm thick.
120 / 0 / 0
Standard
(See Note 5 & 8)
(See Note 8)
(See Note 6 & 8)
20 Nov 2011
227
PART 3: SECTION 1 FIRE DAMPERS Product Name
Model / Installation frame
Maximum Duct size Width (mm)
Maximum Duct size Height (mm)
Maximum Duct size Diameter (mm)
Approved Installation/Construction
A, B, I, C & O / Vertical plane BF
1200
1000
1000
Infill greater than 600mm Ref FD M7B-r1 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition within an opening in a steel stud partition minimum 140mm thick.
A, B, I, C & O / Vertical plane BF
1200
1000
1000
BS EN 1366-2 Fire performance (min) Integrity/ Insulation/ Leakage 120 / 0 / 0
Standard
Infill greater than 600mm Ref FD M8-r1 mounted using 2 x 10mm Ø threaded steel studs, 1 either side of the damper casing fixed to steel cleats welded to the top & bottom of the damper casing in a Firetherm Intubatt 1 fire barrier partition within an opening in a masonry wall minimum 100mm thick & of minimum nominal density 650kg/m3.
120 / 0 / 0
Standard
Ref. FD M9 mounted using an angle frame in a min 100mm - max 200mm thick steel stud partition.
120 / 0 / 0
Standard
LPS 1162 Class (Note 1)
Cert. No.
(See Note 6, 7 & 8)
(See Note 6 & 7)
A, B, I, C & O / Vertical plane AF
1200
1000
1000
(See Note 9)
Notes: 1. See LPS 1162: Issue 4. Table 1 2. LPCB Ref No. 828a/04 approval covers FD dampers constructed from galvanised steel only. 3.. LPCB Ref No. 828a/03, approval covers FSD-TD dampers constructed from a galvanised steel casing with stainless steel blades, with the exception of the FSD-TD-AF damper which has galvanised steel casing with galvanised blades. 4. The sleeve protrudes from each face of the wall by at least 20mm. The continuous external angles (minimum 40mm x 40mm) are riveted to the sleeve on both sides of the wall at maximum 150mm centres. Similar internal angles secure the sleeve to the damper casing. 5. The Firetherm Intubatt 1 fire barrier system comprises of 2 layers of 50mm-thick Firetherm Intubatt 1 (minimum density 180kg/m³) seperated by a cavity of 40mm and factory coated on both faces with a 1mm-thick coating of ablative mastic. The perimeter of the coated batts is retained within galvanised steel angles, 50mm x 50mm x 2m, secured at maximum 300mm centres. The junctions between the damper and the coated batt are pattressed on both sides of the barrier with strips of Firetherm Intubatt 1, 50mm thick x 150mm wide, which are secured by bedding on a layer of Intucoat mastic and fixing with steel pig-tail screws at maximum 200mm centres. Maximum distance between the damper and the reveal of the wall opening is 600mm. 6. A perimeter frame work of steel angles 50mm x 50mm x 2mm is secured on each side of the opening between the damper and the reveal of the wall at 300mm centres. Steel angles are then fixed back-to-back at 300mm centres to form T-sections, which are then fixed around the damper to form a frame, of which its sides are no more than 600mm from the damper. The T-section from is secured to the perimeter frame using a series of T-sections positioned at maximum 600mm centres in one direction and 1200mm centres in the other direction. For barriers where the distance between the top of the damper and the top of the barrier is greater than 1.5m, a deflection head detial is required. The maximum distance between the damper and the wall or floor must not exceed 3m. 7. The Partition comprised of a steel framework of 50mm studs clad on each face with two layers of 12.5mm-thick Firecheck GTEC plasterboard, with the voids between the studs insulated with one layer of 25mm-thick Knauf Acoustic Partition Roll (minimum density 19.5kg/m³) with the aperture to be lined with one layer of 12.5mm-thick Firecheck GTEC plasterboard. The dry fit sleeve & angle system comprises of a 1.2mm-thick top hat section damper casing and 300mm long sleeves with 40mm x 40mm angle type frame work riveted to the sleeve using 4.8mm Ø steel rivets, centrally positioned within the aperture to act as a carrier frame. 8. The Partition comprised of a steel framework, of 50mm studs clad on each face with two layers of 12.5mm-thick Firecheck GTEC plasterboard, with the voids between the studs insulated with one layer of 50mm-thick Rockwool Flexi Slab (minimum density 35kg/m³), with the aperture to be lined with one layer of 12.5mm-thick Firecheck GTEC plasterboard. The angle frame comprises of a steel angle formed from 1.2mm steel and is secured to one side of the damper casing using stitch welds 6-10mm long, at nominal 150mm centres. The leg of the angle fixed to the damper casing is 35mm long. The other leg of the angle must be long enough to
228
20 Nov 2011
PART 3: SECTION 1 FIRE DAMPERS overlap the partition and be secured at nominal 300mm centres. On the other side of the partition the damper is pattressed on all four sides using one or more layers of 12.5mm-thick Firecheck GTEC plasterboard cover strips which must overlap the partition by at least 65mm. The cover strips are secured using suitable screws at 300mm centres. A bead of fire/acoustic sealant must be applied between the edges of each pattress and the spigot & between each pattress and the spigot & between each pattress and the face of the partition.
20 Nov 2011
229
PART 3: SECTION 2 FIRE RESISTANT DUCTS
Fire resistant ductwork is installed:
To maintain compartmentation when air distribution ducts pass through compartment walls and floors where fire resisting dampers are not used to provide the compartmentation To achieve the same fire resistance in terms of integrity, and if required insulation, as required for the compartment walls or floors.
All the fire resistant ducts listed in Section 2 of this part of the list have been tested and assessed against the requirements of BS 476:Part 24 Fire tests on building materials and structures: Method for determination of the fire resistance of ventilation ducts. Certification is limited to the applications and fire resistances given.
Fire Protection Limited Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 231 E-mail: [email protected] • Website: www.fireprotection.co.uk Certificate No: 277a to BS 476: Part 24 Product Name
Duct Type
Condition
Type of Insulation (kg/m3)
Insulation Thickness (mm)
Flamebar BW11
Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet
Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside
45 45 60 60 60 105 105 105 60 105 105 105 45 45 60 105 60 105 105 60 105 105 105 45 45 60 60 60 105 105 105 60 105 105 105
25 60 40 50 120 50 80 50 120 80 120 100** 25 60 50 50 120 80 120 120 80 120 100** 25 60 40 50 120 50 80 50 120 80 120 100**
230
Fire Resistance Integrity (min) 120 240 120 120 120 120 120 120 120 240 240 240 240 240 120 240 120 120 120 120 120 120 120 240 240 240 240 120 240 120 120 120 120 120 120 120 240 240 240 240 240
Fire Resistance Insulation (min) 15 15 60 60 90 118 120 120 120 208 240 240 240 240 30 30 45 60 90 90 120 90 90 120 120 15 15 60 60 90 118 120 120 120 208 240 240 240 240
Cert. No.
277a/01
20 Nov 2011
PART 3: SECTION 2 FIRE RESISTANT DUCTS Product Name
Duct Type
Condition
Type of Insulation (kg/m3)
Insulation Thickness (mm)
Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract
Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside
45 45 60 105 60 105 105 60 105 105 105 60 60 105 60 105 105 60 105 105 105 45 45 60 105 60 105 105 60 105 105 105
25 60 50 50 120 80 120 120 80 120 100** 50 60 50 120 80 50 120 80 120 100** 25 60 50 50 120 80 120 120 80 120 100**
Fire Resistance Integrity (min) 120 240 120 120 120 120 120 120 120 240 240 240 240 120 240 120 120 120 120 120 240 240 240 240 240 120 240 120 120 120 120 120 120 120 240 240 240 240
Fire Resistance Insulation (min) 30 30 45 60 90 90 120 90 90 120 120 15 15 28* 30* 44* 45* 45* 44* 45* 45* 60* 60* 30 30 45 60 90 90 120 90 90 120 120
Cert. No.
Notes: 1. All ducts are protected with 0.7mm to 1.0mm nominal thickness of Flamebar BW11 Fire Proofing. 2. Maximum hanger centres are 1500mm for fire ratings up to two hours and 1000mm for fire ratings up to four hours. 3. The 50mm thick x 60kg/m3 density mineral wool insulation may be in the form of either slabs or wrap. * Refers to internal face inside furnace. ** Includes 500mm x 25mm x 105kg/m3 density mineral wool collar around duct on both sides of penetration seals through fire compartment walls and floors.
Firespray International Limited Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 232 E-mail: [email protected] • Website: www.firespray.eu.com Certificate No: 415a to BS 476: Part 24 Product Name
Duct Type
Condition
Type of Insulation (kg/m3)
Insulation Thickness (mm)
Flamebar BW11
Ventilation Ventilation Ventilation Ventilation
Fire outside Fire outside Fire outside Fire outside
45 45
25 60
20 Nov 2011
Fire Resistance Integrity (min) 120 240 120 120
Fire Resistance Insulation (min) 15 15 60 60
Cert. No.
415a/01
231
PART 3: SECTION 2 FIRE RESISTANT DUCTS Product Name
232
Duct Type
Condition
Type of Insulation (kg/m3)
Insulation Thickness (mm)
Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Ventilation Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Smoke outlet Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract
Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire outside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside Fire inside
60 60 60 105 105 105 60 105 105 105 45 45 60 105 60 105 105 60 105 105 105 45 45 60 60 60 105 105 105 60 105 105 105 45 45 60 105 60 105 105 60 105 105 105 60 60 105 60 105 105 60 105 105 105 45 45 60 105 60 105
40 50 120 50 80 50 120 80 120 100** 25 60 50 50 120 80 120 120 80 120 100** 25 60 40 50 120 50 80 50 120 80 120 100** 25 60 50 50 120 80 120 120 80 120 100** 50 60 50 120 80 50 120 80 120 100** 25 60 50 50 120 80
Fire Resistance Integrity (min) 120 120 120 120 120 240 240 240 240 240 120 240 120 120 120 120 120 120 120 240 240 240 240 120 240 120 120 120 120 120 120 120 240 240 240 240 240 120 240 120 120 120 120 120 120 120 240 240 240 240 120 240 120 120 120 120 120 240 240 240 240 240 120 240 120 120 120 120 120 120
Fire Resistance Insulation (min) 90 118 120 120 120 208 240 240 240 240 30 30 45 60 90 90 120 90 90 120 120 15 15 60 60 90 118 120 120 120 208 240 240 240 240 30 30 45 60 90 90 120 90 90 120 120 15 15 28* 30* 44* 45* 45* 44* 45* 45* 60* 60* 30 30 45 60 90 90
Cert. No.
20 Nov 2011
PART 3: SECTION 2 FIRE RESISTANT DUCTS Product Name
Duct Type
Condition
Type of Insulation (kg/m3)
Insulation Thickness (mm)
Kitchen extract Kitchen extract Kitchen extract Kitchen extract Kitchen extract
Fire inside Fire inside Fire inside Fire inside Fire inside
105 60 105 105 105
120 120 80 120 100**
Fire Resistance Integrity (min) 120 240 240 240 240
Fire Resistance Insulation (min) 120 90 90 120 120
Cert. No.
Notes: 1. All ducts are protected with 0.7mm to 1.0mm nominal thickness of Flamebar BW11 Fire Proofing. 2. Maximum hanger centres are 1500mm for fire ratings up to two hours and 1000mm for fire ratings up to four hours. 3. The 50mm thick x 60kg/m3 density mineral wool insulation may be in the form of either slabs or wrap. * Refers to internal face inside furnace. ** Includes 500mm x 25mm x 105kg/m3 density mineral wool collar around duct on both sides of penetration seals through fire compartment walls and floors.
Flameshield Products Limited 9 Zillah Gardens, Wigmore, Gillingham, Kent ME8 0EE, United Kingdom Tel: 01322 558887 E-mail: [email protected] Certificate No: 785a to BS 476: Part 24 Product Name
Duct Type
Condition
Type / density of insulation
Flameshield
Ventilation Smoke outlet Kitchen extract Ventilation
Fire inside Fire inside Fire inside
Kitchen extract Ventilation
Fire outside Fire outside Fire outside Fire inside
Ventilation
Fire inside
Ventilation
Fire inside
Ventilation
Fire inside
Ventilation
Smoke outlet
Fire outside Fire outside Fire outside Fire outside Fire inside
Smoke outlet
Fire inside
Smoke outlet
Fire inside
Smoke outlet
Fire inside
Smoke outlet
Fire outside Fire outside
Smoke outlet
Ventilation Ventilation Ventilation
Smoke outlet
20 Nov 2011
None None None
Insulation Thickness (mm) -
Fire Resistance (Integrity/ stability) 240 120 120
Fire Resistance (Insulation) -
None
-
120
-
None
-
120
None
-
120
-
Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3
40
120
30
55
120
60
70
120
90
90
240
120
30
120
30
40
120
60
45
120
90
50
120
120
40
120
30
55
120
60
70
120
90
90
120
120
30
120
30
40
120
60
Cert. No. 785a/03
785a/04
233
PART 3: SECTION 2 FIRE RESISTANT DUCTS Product Name
Duct Type
Condition
Type / density of insulation
Smoke outlet
Fire outside Fire outside Fire inside
Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3 Mineral wool 165 kg/m3
Smoke outlet Kitchen extract Kitchen extract Kitchen extract Kitchen extract
Fire inside Fire outside Fire outside
Insulation Thickness (mm) 45
Fire Resistance (Integrity/ stability) 120
Fire Resistance (Insulation) 90
50
120
120
45
120
30
90
120
60
45
120
30
90
120
60
Cert. No.
Notes: 1. LPCB Ref. No's. 785a/03 and 785a/04 - Uninsulated and Insulated ductwork systems to be manufactured and installed to the specifications as detailed in BRE Assessment Report CC 255037 Issue 5 dated 8 July 2011. 2. LPCB Ref. No's 785a/03 and 785a/04 - Covers rectangular and flat oval ductwork up to 3000mm wide x 2000mm deep, reference Flameshield Tables 1 - Issue F & 4 - Issue E and circular ductwork up to 1250mm diameter, reference Flameshield Tables 5 - Issue D and 6 - Issue D. The Flameshield systems may also be employed as attenuator casings as defined in BRE Assessment Report CC 255037 Issue 5 dated 8 July 2011 however the LPCB approval does not cover the attenuator itself. 4. LPCB Ref. No's 785a/03 and 785/04 - Approval also covers Uninsulated and Insulated ductwork systems manufactured to Flameshield Table 20 - Issue F for ventilation duct applications only with a fire resistance intergrity and stability period of up to 120 minutes and where applicable, an insulation period as detailed in BRE Assessment Report CC 255037 Issue 5 dated 8 July 2011. Ductwork manufacturers: The following Companies manufacture the products listed on this certificate to a specification issued and controlled by Flameshield. These companies are audited by the LPCB to ensure the product certification requirements are met. Kent Ductwork Limited (LPCB Ref. 785a(1)) Unit 7/9 Crayford Ind Est Swaisland Drive Crayford Dartford DA1 4HS E & S Heating and Ventilation Limited (LPCB Ref. 785a(2)) Diplocks Way Hailsham East Sussex BN27 3JF Gardner & Co. (Kent) Limited (LPCB Ref. 785a(3)) Unit 2, 23 Revenge Road Lordswood Industrial Estate Chatham Kent ME5 8UD Whitehouse Engineering Co. Limited (LPCB Ref. 785a(4)) 14 Trench Road Mallusk Newtownabbey Co. Antrim Northern Ireland BT36 4UU
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Certificate No: 022f to BS476 : Part 24 : 1987
234
20 Nov 2011
PART 3: SECTION 2 FIRE RESISTANT DUCTS Product Name
Duct Type
Condition
FirePro
Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation
20 Nov 2011
Fire Outside
Maximum Duct size (ht x wt) (mm) 100 x 1000
Insulation Thickness (mm) 25
Fire Resistance Integrity (min) 30
Fire Resistance Insulation (min) 30
Fire Outside
1000 x 1000
30
60
60
Fire Outside
1500 x 1500
50
90
90
Fire Outside
1500 x 1500
70
120
120
Fire Outside
1525 dia.
25
30
30
Fire Outside
1525 dia.
30
60
60
Fire Outside
1525 dia.
50
90
90
Fire Outside
1525 dia.
70
120
120
Fire Outside
1000 x 1000
25
30
30
Fire Outside
1500 x 1500
40
60
60
Fire Outside
1200 x 1200
70
90
90
Fire Outside
1000 x 1000
90
120
120
Fire Outside
1525 dia.
25
30
30
Fire Outside
1525 dia.
40
60
60
Fire Outside
1525 dia.
70
90
90
Fire Outside
1525 dia.
90
120
120
Fire Inside
1000 x 1000
25
30
30
Fire Inside
1000 x 1000
30
60
60
Fire Inside
1500 x 1500
50
90
90
Fire Inside
1500 x 1500
70
120
120
Fire Inside
1525 dia.
25
30
30
Fire Inside
1525 dia.
30
60
60
Fire Inside
1525 dia.
50
90
90
Cert. No. 022f/01
235
PART 3: SECTION 2 FIRE RESISTANT DUCTS Product Name
236
Duct Type
Condition Fire Inside
Maximum Duct size (ht x wt) (mm) 1525 dia.
Insulation Thickness (mm) 70
Fire Resistance Integrity (min) 120
Fire Resistance Insulation (min) 120
Ventilation vertical orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation
Fire Inside
1000 x 1000
25
30
30
Fire Inside
1500 x 1500
40
60
60
Fire Inside
1200 x 1200
70
90
90
Fire Inside
1000 x 1000
90
120
120
Fire Inside
1525 dia.
25
30
30
Fire Inside
1525 dia.
40
60
60
Fire Inside
1525 dia.
70
90
90
Fire Inside
1525 dia.
90
120
120
Fire Outside
1000 x 1000
25
30
30
Fire Outside
1000 x 1000
30
60
60
Fire Outside
1500 x 1500
50
90
90
Fire Outside
1500 x 1500
70
120
120
Fire Outside
1525 dia.
25
30
30
Fire Outside
1525 dia.
30
60
60
Fire Outside
1525 dia.
50
90
90
Fire Outside
1525 dia.
70
120
120
Fire Outside
1000 x 1000
25
30
30
Fire Outside
1500 x 1500
40
60
60
Fire Outside
1200 x 1200
70
90
90
Fire Outside
1000 x 1000
90
120
120
Fire Outside
1525 dia.
25
30
30
Fire Outside
1525 dia.
40
60
60
Cert. No.
20 Nov 2011
PART 3: SECTION 2 FIRE RESISTANT DUCTS Product Name
Duct Type
Condition
Ventilation horizontal orientation Ventilation horizontal orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation vertical orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Ventilation horizontal orientation Kitchen extract Kitchen extract
20 Nov 2011
Fire Outside
Maximum Duct size (ht x wt) (mm) 1525 dia.
Insulation Thickness (mm) 70
Fire Resistance Integrity (min) 90
Fire Resistance Insulation (min) 90
Fire Outside
1525 dia.
90
120
120
Fire Inside
1000 x 1000
25
30
30
Fire Inside
1000 x 1000
30
60
60
Fire Inside
1500 x 1500
50
90
90
Fire Inside
1500 x 1500
70
120
120
Fire Inside
1525 dia.
25
30
30
Fire Inside
1525 dia.
30
60
60
Fire Inside
1525 dia.
50
90
90
Fire Inside
1525 dia.
70
120
120
Fire Inside
1000 x 1000
25
30
30
Fire Inside
1500 x 1500
40
60
60
Fire Inside
1200 x 1200
70
90
90
Fire Inside
1000 x 1000
90
120
120
Fire Inside
1525 dia.
25
30
30
Fire Inside
1525 dia.
40
60
60
Fire Inside
1525 dia.
70
90
90
Fire Inside
1525 dia.
90
120
120
Fire Outside Fire Outside
1500 x 1500 1000 x 1000
40 90
30 60
30 60
Cert. No.
237
PART 3: SECTION 3 SMOKE CURTAINS
Smoke curtains are used:
To create a smoke reservoir by containing and limiting the travel of smoke. To channel smoke in a predetermined direction. To prevent or retard smoke entry to another area or void.
All the smoke curtains listed in Section 3 of this part of the list have been tested and assessed against the requirements of LPS 1182 Requirements and tests for fixed fabric smoke curtains, fixed metal smoke curtains and powered smoke curtains.
238
20 Nov 2011
PART 3: SECTION 4 POWERED SMOKE AND HEAT EXHAUST VENTILATION
Powered smoke and heat exhaust ventilation fans are used:
To channel heat and smoke in a predetermined direction. To prevent smoke logging of the protected space.
All the fans listed have been approved against the requirements of BSEN 12101-3 Smoke and heat control systems. Part 3 Specification for powered smoke and heat exhaust ventilation.
Elta Fans Limited 17 Barnes Wallis Road, Segensworth East Industrial Estate, Farnham, Hampshire PO15 5ST, United Kingdom Tel: +44 (0) 1489 566555 • Fax: +44 (0) 1489 566555 E-mail: [email protected] • Website: www.eltafans.com Additional Manufacturing Site 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands DY6 7US, United Kingdom
Certificate No: 937a to BS EN 12101-3: 2002
20 Nov 2011
239
PART 3: SECTION 4 POWERED SMOKE AND HEAT EXHAUST VENTILATION Product Name SmokeVent axial fan (notes 2, 5, 6, 7, 8)
JetVent Impulse (flanged - standard thrust) axial fan (notes 2, 5, 6, 7, 8)
240
Model LCS025, LCS031, LCS035, LCS040, LCS045, LCS050, LCS056, LCS063, LCS071, LCS080, LCS090, LCS100, LCS112, LCS125, LCS140, LCS160, LCS180, LCS200, SCS025, SCS031, SCS035, SCS040, SCS045, SCS050, SCS056, SCS063, SCS071, SCS080, SCS090, SCS100, SCS112, SCS125, SCS140, SCS160, SCS180, SCS200, LCSCR025, LCSCR031, LCSCR035, LCSCR040, LCSCR045, LCSCR050, LCSCR056, LCSCR063, LCSCR071, LCSCR080, LCSCR090, LCSCR100, LCSCR112, LCSCR125, LCSCR140, LCSCR160, LCSCR180, LCSCR200 JFSU-CPA-315 2/4-3, JFSU-CPA-400 2/4-3, JFSU-CPA-400 2-3, JFSR-CPA-315 2/4-3, JFSR-CPA-400 2/4-3, JFSR-CPA-400 2-3
Application Classes
Response delay N/A
Resistance to fire class F200
Motor temp. rating1 Class F / Class H
insulated or uninsulated; smoke reservoir or non smoke reservoir; dual purpose or emergency use
insulated or uninsulated; smoke reservoir or non smoke reservoir; dual purpose or emergency use
N/A
F200
Class F / Class H
Cert. No. 937a/01
20 Nov 2011
PART 3: SECTION 4 POWERED SMOKE AND HEAT EXHAUST VENTILATION Product Name JetVent Impulse (flanged - enhanced thrust) axial fan (notes 2, 5, 6, 7, 8)
SmokeVent axial fan (notes 2, 5, 6, 7, 8)
20 Nov 2011
Model LCS031-CPU 2/4-3, LCS035-CPU 2/4-3, LCS040-CPU 2/4-3, LCS031-CPR 2/4-3, LCS035-CPR 2/4-3, LCS040-CPR 2/4-3 LCS025, LCS031, LCS035, LCS040, LCS045, LCS050, LCS056, LCS063, LCS071, LCS080, LCS090, LCS100, LCS112, LCS125, LCS140, LCS160, LCS180, LCS200, SCS025, SCS031, SCS035, SCS040, SCS045, SCS050, SCS056, SCS063, SCS071, SCS080, SCS090, SCS100, SCS112, SCS125, SCS140, SCS160, SCS180, SCS200, LCSCR025, LCSCR031, LCSCR035, LCSCR040, LCSCR045, LCSCR050, LCSCR056, LCSCR063, LCSCR071, LCSCR080, LCSCR090, LCSCR100, LCSCR112, LCSCR125, LCSCR140, LCSCR160, LCSCR180, LCSCR200
Application Classes
Response delay
Motor temp. rating1 Class F / Class H
Cert. No.
N/A
Resistance to fire class F200
insulated or uninsulated; smoke reservoir or non smoke reservoir; dual purpose or emergency use
insulated or uninsulated; smoke reservoir or non smoke reservoir; dual purpose or emergency use
N/A
F3004
Class F / Class H
937a/02
241
PART 3: SECTION 4 POWERED SMOKE AND HEAT EXHAUST VENTILATION Product Name JetVent impulse (flanged - standard thrust) axial fan (notes 2, 5, 6, 7, 8)
JetVent impulse (flanged - enhanced thrust) axial fan (notes 2, 5, 6, 7, 8)
SmokeVent axial fan (notes 2, 5, 6, 7, 8)
JetVent centrifugal (Mark I) fan (notes 3, 5, 8)
242
Model JFSU-CPA-315 2/4-3, JFSU-CPA-400 2/4-3, JFSU-CPA-400 2-3, JFSR-CPA-315 2/4-3, JFSR-CPA-400 2/4-3, JFSR-CPA-400 2-3 LCS031-CPU 2/4-3, LCS035-CPU 2/4-3, LCS040-CPU 2/4-3, LCS031-CPR 2/4-3, LCS035-CPR 2/4-3, LCS040-CPR 2/4-3 LCS025, LCS031, LCS035, LCS040, LCS045, LCS050, LCS056, LCS063, LCS071, LCS080, LCS090, LCS100, LCS112, LCS125, SCS025, SCS031, SCS035, SCS040, SCS045, SCS050, SCS056, SCS063, SCS071, SCS080, SCS090, SCS100, SCS112, SCS125, LCSCR025, LCSCR031, LCSCR035, LCSCR040, LCSCR045, LCSCR050, LCSCR056, LCSCR063, LCSCR071, LCSCR080, LCSCR090, LCSCR100, LCSCR112, LCSCR125 JISU-CPC-50N, JISU-CPC-100N,
Application Classes
Response delay N/A
Resistance to fire class F3004
Motor temp. rating1 Class F / Class H
insulated or uninsulated; smoke reservoir or non smoke reservoir; dual purpose or emergency use
insulated or uninsulated; smoke reservoir or non smoke reservoir; dual purpose or emergency use
N/A
F3004
Class F / Class H
insulated or uninsulated; smoke reservoir or non smoke reservoir; dual purpose or emergency use
N/A
F400
Class F / Class H
937a/03
uninsulated; smoke reservoir; dual purpose or emergency use
N/A
F300
Class F / Class H
937a/04
Cert. No.
20 Nov 2011
PART 3: SECTION 4 POWERED SMOKE AND HEAT EXHAUST VENTILATION Product Name JetVent -centrifugal (Mark II) fan (notes 3, 5, 8) JetVent impulse (unflanged standard thrust) axial fan (notes3, 5, 8)
Model JISU-2-CPC50N, JISU-2-CPC100N, JVSU-CPA-315 2/4-3, JVSU-CPA-400 2-3, JVSU-CPA-400 2/4-3, JVSR-CPA-315 2/4-3, JVSR-CPA-400 2-3 JVSR-CPA-400 2/4-3
Application Classes
Response delay N/A
Resistance to fire class F3004
Motor temp. rating1 Class F / Class H
uninsulated; smoke reservoir; dual purpose or emergency use uninsulated; smoke reservoir; dual purpose or emergency use
N/A
F3004
Class F / Class H
Cert. No. 937a/05
937a/06
Notes: 1. Motor temperature rating - classes given refer to temperature rise at ambient and motor insulation as detailed in section 4.2 of EN 12101-3: 2002. 2. Both horizontal and vertical installation is permitted. 3. Horizontal installation only is permitted. 4. Tested to 300°C for 120 minutes. 5. Only certified accessories should be used. 6. Use of guide vanes is permitted. Where this is the case the model code has +GV added, e.g. LCS025+GV. 7. Fan coding of units held within Select stock will be prefixed by the letter ‘S’, and the size expressed in mm (i.e. LCS025 becomes SLCS250) 8. No ducted cooling air is required.
20 Nov 2011
243
PART 3: SECTION 5 GREASE FILTERS USED IN COMMERCIAL KITCHEN EXTRACT SYSTEMS
LPS 1263 Requirements for the LPCB Approval and Listing of the Fire Performance of Grease Filters Used in Commercial Extract systems. This standard covers the test procedures and method of calculating the fire performance rating of grease filters used for the reduction of flammable and volatile grease droplets from the cooking exhaust of commercial cooking equipment in such situations as restaurant kitchens, canteens or similar food preparation areas where it is necessary to reduce the cooking exhause via a ventilation system.
Halton Foodservice Limited 11 Laker Road, Airport Industrial Estate, Rochester, Kent ME1 3QX, United Kingdom Tel: +44 (0)1634 666111 • Fax: +44 (0)1634 666333 E-mail: [email protected] • Website: www.halton.com/foodservice Certificate No: 996a to LPS 1263 issue 1.2 Product Name KSA Filter
Nominal filter size (w x h x t) (mm) 498 x 330 x 51.6
Nominal flow rate (m3/h) 786
LPS 1263 Grade
Cert. No.
GF90
996a/01
Notes: 1. LPCB ref 996a/01 The KSA filter is manufactured from Grade 304 S16 stainless steel with 0.4mm thick filter fins and 0.8mm casing. 2. LPCB ref 996a/01 KSA filter is approved as part of a Kitchen Ventilation system with 400, 555 and 555UV canopy profiles only.
244
20 Nov 2011
Part 4 SECURITY PROTECTION PRODUCTS
PART 4: SECURITY PROTECTION PRODUCTS INTRODUCTION Security products and services approved by LPCB play an important role in protecting people and property against physical attack, burglary, vandalism and terrorism. Statistics from the UK indicate that the addition of appropriate security measures to a home reduces the risk of burglary from 25% to 2.4%. However, it is important that the measures installed are effective. LPCB approval ensures that products developed for use in domestic applications offer effective levels of deterrence and, when required, will resist determined attack by a criminal wishing to gain access to a property. The threat to organisations from commercial crime and terrorism is diverse in both geography and levels of skill involved, it is persistent and requires appropriate measures to deter criminals and terrorists. Improved detection backed up by a fast and effective response, and effective physical security that provides a suitable delay while the response arrives, reduces the likelihood of such act being committed. This is supported by research and initiatives, in the UK, LPCB works closely with Insurers, Government, Police, end users and security equipment specifiers to develop methods by which the quality of product performance and product reliability can be assessed. Using security products approved by LPCB to protect people and assets is an effective way of mitigating many of the risks associated with crime and terrorism. The products listed in this section have been rigorously tested in programmes designed to evaluate resistance to deliberate attack. The scope of the approval of each product is described in the relevant section and on the certificates issued to the approved manufacturer. It is important to ensure that specifiers only select products covered by the scope detailed on the certificate since products outside that scope may not provide an equivalent level of security. The range of products listed in this section is extensive and includes physical barrier type products, asset marking, computer protection equipment as well as electronic detection and surveillance equipment. The range and scope of products submitted for approval continues to grow significantly. Products are approved in accordance with a range of standards. The details of these standards are given at the front of each section relevant to the product.
246
20 Nov 2011
PART 4: SECTION 1.1 INTRUDER DETECTION EQUIPMENT
This section lists components of intruder detection systems where compliance with the applicable EN 50131 series of standards has been demonstrated by LPCB’ experts and most importantly on going assessments confirm the component continues to comply with the requirements. The LPCB’s intruder detection approval schemes reference Loss Prevention Standards LPS 1602 and LPS 1603 which incorporate the requirements of the corresponding EN 50131 series of standards. The Loss Prevention Standards also include specific checks to confirm the intruder detection components are suitable for use in installations complying with the United Kingdom’s document PD 6662 Scheme for the application of European Standards for intruder and hold-up alarm systems and the confirmation technology requirements of BS 8243 in support of the ACPO security systems policy. By obtaining LPCB approval to the relevant LPS, conformance to the applicable requirements of the various European standards, published documents, and policies can be demonstrated. Control and Indicating Equipment LPS 1603 Requirements for LPCB Approval and Listing of Intruder Alarm Control and Indicating Equipment is the standard used for the certification of security system control and indicating equipment. The purpose of this LPS is to list requirements of the performance and suitability for use in installations complying with the United Kingdom’s document PD 6662 Scheme for the application of European Standards for intruder and hold-up alarm systems. The requirements are based on the criteria described in the European Standard EN 50131-3 and where appropriate to the criteria of BS 8243 in support of the ACPO security systems policy. Intruder Alarm Movement Detectors LPS 1602 Requirements for LPCB Approval and Listing of Intruder Alarm Movement Detectors is the standard used for the certification of intruder alarm movement detectors. This Loss Prevention Standard specifies the requirements for LPCB approval of the following types of intruder alarm movement detectors;
Passive infrared Microwave Combined passive infrared and microwave Combined passive infrared and ultrasonic
The purpose of this LPS is to list requirements of the performance of intruder alarm movement detectors and their suitability for use in installations complying with United Kingdom’s document PD 6662 ‘Scheme for the application of European Standards for intruder and hold-up alarm systems’. The requirements are based on the criteria described in the European Standards of EN 50131-2-2, EN 50131-2-3, EN 50131-2-4 and EN 50131-2-5 respectively and to the criteria of BS 8243 in support of the ACPO security systems policy. LPCB approval to this LPS is applicable only to intruder alarm movement detectors intended for mounting inside the premises i.e. not externally located. Note: At the time of going to print no intruder detection equipment was listed as LPCB approved. Please check www.redbooklive.com for updates.
20 Nov 2011
247
PART 4: SECTION 1.2 ALARM TRANSMISSION EQUIPMENT AND SIGNALLING SYSTEMS
This section lists alarm transmission equipment suitable for use with intruder alarm and hold-up systems. Alarm transmission and fault warning routing equipment suitable for use with fire alarm systems is listed in Volume 1 Part 1 Section 10.1. Where alarm transmission equipment is suitable for use with both intruder alarm and hold-up systems and fire alarm systems, the entry for the approved equipment will appear in Volume 2 Part 4 Section 1.2 and Volume 1 Part 1 Section 10 of the Red Book. The following standard is currently used for the approval scheme: LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment Where appropriate within LPS 1277, reference has been made to published standards for intruder alarm and hold-up systems including EN 50131-1 together with the alarm transmission equipment standards of EN 50136. Particular emphasis is placed on the verification of manufacturers’ claims by measuring alarm transmission times over the transmission path(s) between the equipment under test and the corresponding receiving centre. The response to the reporting of fault conditions is measured in a similar way. The results of these measurements are expressed in terms of alarm transmission system (ATS) performance criteria classification, using the parameters D, M, T and where applicable S and I. Where: D = Transmission time classification M = Transmission time maximum values T = Reporting time classification S = Substitution Security I = Information Security Availability is considered a key parameter under LPCB approval and is therefore included within the requirements of LPS 1277 and the resultant performance is expressed using the parameter ‘A’ for Availability. The measured parameters are used to determine the performance classification in terms of ATS level (1 to 6) that when used in conjunction with warning devices provide the security grade of the intrusion and hold-up alarm system (I&HAS) as defined in EN 50131-1. Products compliant with LPS 1277 Issue 3.0 meet ‘enhanced’ ATS performance classification which includes timed ‘stepped up’ reporting after the loss of the primary path and the reporting of a catastrophic failure, in event of the simultaneous loss of multiple transmission paths. To assist specifiers in their selection of the products most appropriate for protecting their risks, the actual performance parameters measured during the LPCB test programme are included with the product listing entry in the Redbook as an indicator of the level of performance that can be expected from the alarm transmission system. Compliance with relevant safety standards and applicable mandatory directives is a pre-requisite of LPCB approval and listing. Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard. Note Since LPCB uses national and international standards for the listing of products, in some instances, the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.
248
20 Nov 2011
PART 4: SECTION 1.2.1 ALARM TRANSMISSION EQUIPMENT AND SYSTEMS
The equipment listed in this section has been assessed against the requirements and tests methods of LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment. Those components of the alarm transmission system normally located in the protected premises are listed. The alarm transmission and fault monitoring performance has been verified by testing the alarm transmission equipment in conjunction with the appropriate transmission networks. Specifiers are advised to check the product listing for the issue of LPS 1277 against which the alarm transmission equipment is approved. At the time of going to print, the current publication of LPS 1277 was Issue 3.0. Please check www.redbooklive.com for the current publication and the latest product listings.
BT Redcare Monument TE, 11-13 Great Tower Street, London EC3R 5EA, United Kingdom Tel: +44 (0) 800 800 828 • Fax: +44 (0)20 7929 6490 Website: www.redcare.bt.com Certificate No: 775a to LPS 1277: Issue 2.2
Alarm Transmission Equipment Product Name UC-372G-UK ASSURE STAR
Fire Category B
Security Grade 3
Primary Transmission Path Asynchronous digital subscriber line (ASDL) operated by BT Broadband
Secondary Transmission Path General packet radio service (GPRS) on a BT mobile network
Cert. No. 775a/01
Performance Parameters
Transm ission Transm ission Transm ission Reporting Tim e Substitution Inform ation Netw ork Classification Path Time Time Security Security Availability5 Classification Max. Values Primary D4 M32 T5 S2 I3 A3 Secondary 1
Combined
D4
M32
T33
S2
I3
A1
D4
2
T54
S2
I3
A3
M3
Approved Ancillaries AO100 External base antenna (short) BA900-5 High gain antenna (long) CAB0106 10m low loss extension cable UltraCapture8 Video Card UltraCapture4 Video Card Notes: 1. The combined performance parameters are shown for the ASSURE STAR as a whole, i.e. with both primary and secondary transmission paths operational. The alarm transmission performance parameters of the ASSURE STAR are consistent with those of ATS 5. 2. During a planned maintenance procedure the ASSURE STAR will achieve performance classification D4 at a maximum transmission time classification M2. The maintenance procedure will be operated approximately four times per year and will be of approximately 5 minutes duration. 3. The loss of the secondary path following a previous failure of the primary path results in a reporting time classification of T4. 4. The simultaneous loss of the primary and secondary transmission paths results in a reporting time classification of T5. 5. Network availability classifications have been based on the limited availability data. At the time of the initial evaluation only a limited number of ASSURE STAR alarm transmission equipment were in service and these were subject to interruption due to engineering trials whilst the data was being recorded. The monitoring of network availability continues and the classification will be updated when available. When operating with both transmission paths functioning correctly the combined system availability will meet classification A3.
20 Nov 2011
249
PART 4: SECTION 1.2.1 ALARM TRANSMISSION EQUIPMENT AND SYSTEMS
WebWayOne Ltd 11 Kingfisher Court, Hambridge Road, Newbury, Berkshire RG14 5SJ, United Kingdom Tel: +44 (0)1635 231500 • Fax: +44 (0)1635 231539 E-mail: [email protected] • Website: www.webwayone.co.uk Certificate No: 1022b to LPS 1277: Issue 3.0
Alarm Transmission Equipment Certificated Products 22-5005 WebWay IP/GPRS LPS I&HAS 22-5015 WebWay GPRS/PSTN LPS I&HAS
The WebWay IP/GPRS LPS I&HAS comprises equipment part no. 22-5005 plus configuration part no. '1411AD155002' Suitable for use with EN 50131-1 compliant I&HAS up to and including security grade 4, notification Option C. The WebWay GPRS/PSTN LPS I&HAS comprises equipment part no. 22-5015 plus configuration part no. '1411AD155004' Suitable for use with EN 50131-1 compliant I&HAS up to and including security grade 3, notification Option C.
Cert. No. 1022b/01
1022b/02
Approved with the following Ancillaries 22-5054 High performance disc antenna 22-5049-5m High gain extension antenna with 5 metre cable 22-5049-10m High gain extension antenna with 10 metre cable 22-5049-15m High gain extension antenna with 15 metre cable 22-5049-20m High gain extension antenna with 20 metre cable 22-5076 PSTN Dialler PCB module 22-5073 RS232 Serial interface module 22-5076 Modem capture alarm panel interface module The alarm transmission equipment is to be used in accordance with the installation instructions and the guidance of ANNEX C described in LPS 1277 Issue 3.0 ‘Requirements for LPCB Approval and Listing of Alarm Transmission Equipment’. The performance of the above listed products has been found to meet the intrusion and hold-up alarm requirements of LPS 1277 Issue 3.0 with the following performance parameters: Alarm Transmission System Performance Parameters 22-5005 Webway IP/GPRS LPS I&HAS
Product Name
WebWay IP/GPRS LPS I&HAS
Fire Category
N/A
LPCB Performance Classification Dual Path Enhanced ATS 5
Designated T ransmission Paths Cert No Primary
Secondary
Duplicate
Broadband (IP)
GPRS
N/A
1022b/01
Confirmed Performance Parameters
1) 2)
Transmission time Classification1)
Transmission time Max. Values 1)
Reporting time Classification
Substitution Security 1)
Information Security 1)
Netw ork Availability 2)
Enhanced Performance Rating
D4
M3
T4
S2
I3
A4
AT S 5
Minimum performance parameters for primary or secondary path. Network Availability confirmed with both designated primary and secondary paths operating.
ATS path failure
250
20 Nov 2011
PART 4: SECTION 1.2.1 ALARM TRANSMISSION EQUIPMENT AND SYSTEMS Reporting Time Classification
ATS path failure conditions Loss of Primary path only (i.e. secondary path remaining operational) Loss of Secondary path only (i.e. primary path remaining operational) Loss of Secondary path w hilst operating in ‘stepped up’ reporting mode (i.e. the loss of Secondary path some time after a previous loss of the Primary path).
T4 T3 T4 Enhanced AT S 5
Reporting catastrophic 3) failure of ATS commensurate w ith 3)
The detected loss of the primary path followed by immediate detection of loss of the Secondary path. __________________________________________________________________________________________
22-5015 Webway GPRS/PSTN LPS I&HAS
Product Name
Fire Category
WebWay GPRS/PSTN LPS I&HAS
N/A
LPCB Performance Classification Dual Path Enhanced ATS 4 Plus
Designated T ransmission Paths Cert No Primary
Secondary
Duplicate
GPRS
PSTN
N/A
1022b/02
Confirmed Performance Parameters
1) 2)
Transmission time Classification1)
Transmission time Max. Values 1)
Reporting time Classification
Substitution Security 1)
Information Security 1)
Netw ork Availability 2)
Enhanced Performance Rating
D3
M3
T 3 Plus
S2
I3
A4
AT S 4 Plus
Minimum performance parameters for primary or secondary path. Network Availability confirmed with both designated primary and secondary paths operating.
ATS path failure
ATS path failure conditions Loss of Primary path only (i.e. secondary path remaining operational) Loss of Secondary path only (i.e. primary path remaining operational) Loss of Secondary path w hilst operating in ‘stepped up’ reporting mode (i.e. the loss of Secondary path some time after a previous loss of the Primary path).
Reporting catastrophic 3) failure of ATS commensurate w ith 3)
Reporting Time Classification T 3 Plus T3 T 3 Plus
Enhanced AT S 4 Plus
The detected loss of the primary path followed by immediate detection of loss of the Secondary path.
20 Nov 2011
251
PART 4: SECTION 2 SAFES, STRONGROOMS AND SECURE SAFE CABINETS
This section lists safes, strongrooms and secure safe cabinets that have been designed for the secure storage of cash and valuables, but which may also be used to secure other high risk assets, including secure information. The safes, strongrooms and security cabinets listed are graded according to their resistance to manual intervention attack tests. These are undertaken by experienced laboratory test engineers using tools carefully selected to achieve access to the contents of the safe using the minimum time and resistance units possible. Domestic safes and those typically fitted in hotel bedrooms are generally graded in accordance with EN 14450 Secure Storage units - Requirements, classification and methods of test for resistance to burglary Secure safe cabinets. Commercial safes and strongrooms are either graded in accordance with LPS 1183 Specification for safe storage units. Part 1: Safes and strongrooms or EN 1143-1 Secure storage units. Requirements, classification and methods of test for resistance to burglary. Safes, strongroom doors and strongrooms. Deposit safes are graded in accordance with EN 1143-2 Secure storage units. Requirements, classification and methods of test for resistance to burglary. Deposit systems. Cash and Jewellery Ratings Table 1 indicates typical cash and jewellery ratings attributed to safes and strongrooms according to their approved resistance grade. These ratings should only be used as a guide since each insurer defines their own ratings depending on the performance of the safes and the situation in which the safes and strongrooms are to be used. Specifiers are strongly advised to discuss the issue of cash and jewellery ratings with their insurer prior to selecting a safe or strongroom. Table 1: Typical Cash and Jewellery Ratings for Safes and Strongrooms Standard
Resistance grade
EN 14450
S1 S2 0 I II III IV V VI VII to XIII
LPS 1183 and EN 1143-1
Typical overnight cash rating (£k) 2 4 6 10 17.5 35 60 100 150 -
Typical overnight jewellery rating (£k) 20 40 60 100 175 350 600 1000 1500 -
Compatible Locks The locks that have been approved for use on each of the approved safes and strongrooms are listed in the 'compatible locks' section of each manufacturer’s entry in the Red Book. Specifiers and end users are advised that the performance of the safes to the relevant standards is dependent on them being fitted with the locks listed. Installation and maintenance It is important to ensure that safes are installed in accordance with the manufacturer’s instructions and that all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly checked to ensure that they are in good condition and that they have not been tampered with.
252
20 Nov 2011
PART 4: SECTION 2.1 SAFES
The safes listed in this section are approved by LPCB to one or more of the following standards: EN 1143-1 Secure storage units. Requirements, classification and methods of test for resistance to burglary. Safes, strongroom doors and strongrooms. LPS 1183 Specification for safe storage units. Part 1: Safes and strongrooms Copies of LPS 1183 can be downloaded free of charge from our website www.RedBookLive.com. Explosion (EX) Designation This designation indicates a product offers resistance to detonation of a PETN (Pentaerythritol tetranitrate) explosive charge followed by post detonation tool attacks aimed at achieving entry to the safe. Where the use of explosive charges is perceived to be a threat it is recommended products with this designation are selected. Core Drill (CD) Designation This designation is only applicable to safes achieving grades IV and above. This designation reflects the ability of a product to pass the diamond drill test specified within EN 1143-1 which is designed to demonstrate the product’s superior resistance to methods of forced entry that solely involve the use of diamond core drills.
Dudley Safes Limited Unit 17 Deepdale Works, Deepdale Lane, Upper Gornal, Dudley, West Midlands DY3 2AF, United Kingdom Tel: +44 (0)1384 239991 • Fax: +44 (0)1384 455129 Website: www.dudleysafes.com Certificate No: 304a to LPS 1183: Issue 4 and BS EN 1143-1: 2005
Free-standing Safes Product Name
Size Reference
Europa 0 Europa I Europa II Europa III Europa II (Mk.2) Europa 0 (Mk.2) Europa I (Mk.2) Europa III (Mk. 2)
1 to 7 1 to 7 1 to 7 2 to 7 1 to 7 1 to 7 1 to 7 2 to 7
Security Grade 0 I II III II 0 I III
Cert. No. 304a/01 304a/02 304a/03 304a/04 304a/05 304a/06 304a/07 304a/08
Compatible Locks
20 Nov 2011
253
PART 4: SECTION 2.1 SAFES Model
Type
Europa Safe (LPCB Ref. No. 304a/..) 01
02
03
04
05
06
07
08
Auditcon 52
Electronic Combination
Caw i 2648
Mechanical Key
Kaba 252
Electronic Combination
Kaba 525
Electronic Combination
Kaba MAS 552
Electronic Combination
LaGard 1985
Mechanical Combination
LaGard 3330
Mechanical Combination
LaGard 3740
Electronic Combination
LaGard Combogard 33E
Electronic Combination
LaGard Combogard 39E
Electronic Combination
LaGard Combogard 66E
Electronic Combination
M-Locks EM3520
Electronic Combination
M-Locks EM3550
Electronic Combination
Mauer 70079
Mechanical Key
Mauer 71111
Mechanical Key
Opus 060/EM25.20
Electronic Combination
S&G 6730
Mechanical Combination
S&G 6731
Mechanical Combination
Godrej & Boyce Mfg. Co. Ltd. (Security Equipment Division) Plant - 17, Pirojshanagar, Vikhroli, Mumbai 400 079, India Tel: +91 22 679 64771 • Fax: +91 22 679 61509 E-mail: [email protected] or [email protected] • Website: www.godrej.com Certificate No: 954b to BS EN 1143-1: 2005 + A1: 2009 and LPS 1183: Issue 4
Free-standing Safes Product Name
Size Ref:
Euro Cash Grade 3
Euro Cash Grade 4
Euro Cash Grade 5
254
Maximum External Height (mm)1 -
Minimum External Width (mm) 485
Maximum External Width (mm)1 -
Minimum External Depth (mm) 498
Maximum External Depth (mm)1 -
Nominal Weight (kg)
Security Grade
Cert. No.
T14
Minimum External Height (mm) 485
173
III
954b/01
T19
615
-
435
-
498
-
185
III
T23
715
-
550
-
648
-
285
III
T28
830
-
580
-
673
-
337
III
T35
1030
-
640
-
748
-
453
III
T43
1230
-
640
-
748
-
530
III
T51
1430
-
630
-
748
-
600
III
T63
1730
-
800
-
693
-
768
III
T70
1900
-
860
-
748
-
903
III
F23
715
-
550
-
648
-
397
IV
F28
830
-
580
-
673
-
462
IV
F35
1030
-
640
-
748
-
618
IV
F43
1230
-
640
-
748
-
727
IV
F51
1430
-
640
-
748
-
892
IV
F63
1730
-
800
-
693
-
1092
IV
F70
1900
-
860
-
748
-
1307
IV
P23
715
-
550
-
648
-
397
V
P28
830
-
580
-
673
-
462
V
P35
1030
-
640
-
748
-
618
V
P43
1230
-
640
-
748
-
727
V
P51
1430
-
640
-
748
-
892
V
P63
1730
-
800
-
693
-
1092
V
P70
1900
-
860
-
748
-
1307
V
954b/02
954b/03
20 Nov 2011
PART 4: SECTION 2.1 SAFES Product Name
Size Ref:
Euro Cash Grade 6
Euro Cash Grade 0
Euro Cash Grade 1
Maximum External Height (mm)1 -
Minimum External Width (mm) 570
Maximum External Width (mm)1 -
Minimum External Depth (mm) 665
Maximum External Depth (mm)1 -
Nominal Weight (kg)
Security Grade
Cert. No.
H21
Minimum External Height (mm) 735
567
VI
954b/04
H26
850
-
600
-
690
-
667
VI
H24
790
-
690
-
730
-
720
VI
H35
1090
-
690
-
730
-
924
VI
H47
1390
-
690
-
830
-
1219
VI
H55
1590
-
690
-
830
-
1359
VI
H67
1890
-
940
-
830
-
1898
VI
Z14
455
555
455
555
465
565
81
2
0
2
0
Z14S
455
555
405
505
370
470
68
Z19
585
685
405
505
465
565
902
0
Z19D
485
785
420
620
515
715
1212
0
Z23
485
885
420
620
515
715
1352
0
Z28
600
1000
450
650
540
740
1592
0
Z28W
600
1000
510
710
615
815
181
2
0
Z35
800
1200
510
710
615
815
214
2
0
Z35W
800
1200
700
900
615
815
2572
0
2
0
Z43
1000
1400
510
710
615
815
245
Z43W
1000
1400
700
900
615
815
2932
0
Z51
1200
1600
510
710
615
815
2782
0
Z51W
1200
1600
700
950
615
815
3312
0
Z59
1400
1600
420
520
420
620
2422
0
Z59W
1400
1600
460
610
420
520
263
2
0
A14
455
555
455
555
465
565
1222
I
A14S
455
555
405
505
370
470
1002
I
A19
585
685
405
505
465
565
1362
I
A19D
485
785
420
620
515
715
201
2
I
A23
485
885
420
620
515
715
2112
I
A28
600
1000
450
650
540
740
2522
I
A28W
600
1000
510
710
615
815
288
2
I
2
I
A35
800
1200
510
710
615
815
342
A35W
800
1200
700
900
615
815
4142
I
A43
1000
1400
510
710
615
815
3952
I
2
I
A43W
1000
1400
700
900
615
815
476
A51
1200
1600
510
710
615
815
4492
I
A51W
1200
1600
700
950
615
815
539
2
I
A59
1400
1600
420
520
420
620
3842
I
A59W
1400
1600
460
610
420
520
4242
I
954b/05
954b/06
Compatible Locks
Manufacturer
Model
Type
Euro Cash Safes (LPCB Ref. No. 954b/..) 1
Carl Wittkopp GmbH
1824-159-0
Carl Wittkopp GmbH / Insys Microelectronics Kaba AG.
Tw in Lock 7220
Kaba Ilco Corp. Kaba Ilco Corp. Kaba Mauer GmbH
20 Nov 2011
2
3
4
Mechanical key
Electronic combination SL523 and SL525 Electronic combination 673000 Mechanical combination A673000 Mechanical combination President 71111 Mechanical key
5
6
255
PART 4: SECTION 2.1 SAFES Kaba Mauer GmbH
Variator B - 70076 Mechanical key
Kaba Mauer GmbH
Praetor B - 70079 Mechanical key
Kaba Mauer GmbH
Variator A 70091 Mechanical key
Kaba Mauer GmbH
Variator A 70092 Mechanical key
Kaba Mas Corp
Auditcon 2
Kaba Mas Corp
Auditcon 2100D
Kaba Mas Corp
Auditcon 3100
Kaba Mas Corp
Cencon
La Gard
1947
La Gard
1985
La Gard
3330-1
La Gard
3332
La Gard
Low e and Fletcher Ltd
Combogard 3740 (Combo Basic) Combogard 6040 (39E) Combogard 66E w ith deadbolt 3007
Electronic combination Electronic combination Electronic combination Electronic combination Mechanical combination Mechanical combination Mechanical combination Mechanical combination Electronic combination Electronic combination Electronic combination Mechanical key
Low e and Fletcher Ltd
3012
Mechanical key
La Gard La Gard
Alternative Trade Names The Euro Cash safes are also marketed under the following alternative trade names
Trade Nam e Euro Cash Grade 0
Euro Cash Z-Series
Alte rnative Trade Names Euro Trader Grade 0
Euro Trader Z-Series
Euro Cash Grade 1
Euro Cash A-Series
Euro Trader Grade 1
Euro Trader A-Series
Euro Cash Grade 3
Euro Cash T-Series
Euro Trader Grade 3
Euro Trader T-Series
Euro Cash Grade 4
Euro Cash F-Series
Euro Trader Grade 4
Euro Trader F-Series
Euro Cash Grade 5
Euro Cash P-Series
Euro Trader Grade 5
Euro Trader P-Series
Euro Cash Grade 6
Euro Cash H-Series
Euro Trader Grade 6
Euro Trader H-Series
Notes: 1. If no maximum dimension is noted, the model is only approved in a single size; i.e. that listed in the minimum dimension column. 2. The nominal weights noted vary by +/- 5% depending on the size of safe manufactured within the range of dimensions noted for that model. Certificate No: 954c to LPS 1183: Issue 4.2
Free-standing Safe Product Name
Size Ref.
Euro Cash Grade 5
P62
256
Minimum External Height (mm) 1703
Maximum External Height (mm) 1706
Minimum External Width (mm) 688
Maximum External Width (mm) 691
Minimum External Depth (mm) 748
Maximum External Depth (mm)
Security Grade
Cert. No.
751
V
954c/01
20 Nov 2011
PART 4: SECTION 2.1 SAFES
Compatible Locks Manufacturer Kaba AG. Kaba Mas Corp Kaba Mas Corp Kaba Mas Corp Kaba Mas Corp Kaba Mauer GmbH Kaba Mauer GmbH La Gard La Gard
Model Models SL523 and SL525 Auditcon 2100D Auditcon 3100 Auditcon 2 Cencon Variator B - 70076 Praetor B - 70079 1985 3332
Type Electronic combination Electronic combination Electronic combination Electronic combination Electronic combination Mechanical key Mechanical key Mechanical combination Mechanical combination
Notes: 1. The size P62 Euro Cash Grade 5 safe is a double door free-standing safe with integral depository. 2. The security grade applies to the safe when both doors are closed, fully locked and the keys removed. 3. The resistance of the horizontal divider and the deposit mechanism incorporated within that divider to manual forced entry attacks is outside the scope of this approval, as is the resistance to fishing and trapping provided by the deposit facility located within that divider.
Lion Steelworks SDN. BHD. Lot 4, Solok Waja 3, Kawasan Perindustrian Bukit Raja, 41050 Klang, Selangor, Malaysia Tel: +603 3341 3822 • Fax: +603 3342 7630 E-mail: [email protected] Certificate No: 639a to LPS 1183: Issue 4
Free-standing Safes Product Name
Size Reference N1, N2 and N3
N-Series
Security Grade III
Cert. No. 639a/01
Compatible Locks
Manufacturer
Model
S&G6731
Mechanical Combination
S&G6880
Mechanical Key
Note: 1. LPS 1183: Issue 4 is equivalent to BS EN 1143-1:1997 with the exception of the requirement for the locks to meet ENV 1300.
SMP Security Limited Halesfield 24, Telford, Shropshire TF7 4NZ, United Kingdom Tel: +44 (0)1952 585673 • Fax: +44 (0)1952 582816 E-mail: [email protected] • Website: www.smpsecurity.co.uk Certificate No: 115a to LPS 1183: Issue 3
Free-standing Safes Product Name
Size References1, 2
Community
1414 (39) ED (58) 1814 (50) ED (74) 2316 (103) ED (138) 2916 (130) ED (174) 3520 (230) ED (297) 5020 (328) ED (424) 6020 (393) ED (509) Mini-Vault (702) ED (910)
20 Nov 2011
Security Grade I
Fire Resistance to BS 476: Part 20: 1987 60
Cert. No. 115a/01
257
PART 4: SECTION 2.1 SAFES Product Name
Size References1, 2 1814 (50) ED (74) 2316 (103) ED (138) 2916 (130) ED (174) 3520 (230) ED (297) 5020 (328) ED (424) 6020 (393) ED (509) Mini-vault (702) ED (910) 1814 (50) ED (74) 2316 (103) ED (138) 2916 (130) ED (174) 3520 (230) ED (297) 5020 (328) ED (424) 6020 (393) ED (509) Mini-vault (702) ED (910) 60 50 40 (120) ED (165) 90 50 40 (180) ED (247) 90 40 47.5 (171) 92 42 48.5 (187.4) 120 50 40 (240) ED (330) 120 40 47.5 (228) 122 42 48.5 (248.5) 150 50 40 (300) ED (412)
Security Grade II
Fire Resistance to BS 476: Part 20: 1987 60
Cert. No.
III
60
115a/03
IV
-
115a/04
115a/02
Compatible Locks
Lock
Type
Carl Wittkopp GmbH 1819 Carl Wittkopp GmbH 1821 Kaba Mas Corporation SL 523 Kaba Mas Corporation SL 525 KG Group EM25-20 KG Group EM35-20 KG Group ML67-40 La Gard 1947 La Gard 1985 La Gard 3330 La Gard Combogard 33E La Gard Combogard 3740 (Combo Basic) La Gard Combogard 6040 (39E) La Gard Combogard 66E w ith deadbolt La Gard Safeguard 3000/2441 La Gard Safeguard 3035/2441 Low e and Fletcher 3007 Low e and Fletcher 3010 Low e and Fletcher 3011 Low e and Fletcher 3012 Mauer 70076 Mauer 70077 Mauer 70079 Mauer 70091 Mauer 70092 Mauer 71111 S&G 6730 S&G 6731 SMP S520D7-C SMP S520D9-C
Mechanical key Mechanical key Electronic combination Electronic combination Electronic combination Electronic combination Mechanical combination Mechanical combination Mechanical combination Mechanical combination Electronic combination Electronic combination Electronic combination Electronic combination Electronic combination Electronic combination Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical combination Mechanical combination Mechanical key Mechanical key
Com m unity Safe (LPCB Ref. No. 115a/…) 1 2 3 4
Notes: 1. ED denotes available with up to 150mm extra depth. 2. Figures in brackets denote the volumes in litres. The first figure is the standard volume, the second figure is the volume of safe with maximum 150mm extra depth.
258
20 Nov 2011
PART 4: SECTION 2.1 SAFES
Certificate No: 115b to LPS 1183: Issue 4
Free-standing Safes Product Name
Size References1, 2
Community
1414 (39) ED (58) 1814 (50) ED (74) 2316 (103) ED (138) 2916 (130) ED (174) 3520 (230) ED (297) 5020 (328) ED (424) 1414 (39) ED (58) 1814 (50) ED (74) 2316 (103) ED (138) 2916 (130) ED (174) 3520 (230) ED (297) 5020 (328) ED (424) 60 50 40 (120) ED (165) 90 50 40 (180) ED (247) 120 50 40 (240) ED (330) 150 50 40 (300) ED (412)
Security Grade 0
Fire Resistance to BS 476:Part 20: 1987 60
Cert. No.
0
60
115b/11
V
-
115b/05
115b/10
Compatible Locks
Lock
Type
Carl Wittkopp GmbH 1819 Carl Wittkopp GmbH 1821 Kaba Mas Corporation SL 523 Kaba Mas Corporation SL 525 KG Group EM25-20 KG Group EM35-20 KG Group ML67-40 La Gard 1947 La Gard 1985 La Gard 3330 La Gard Combogard 33E La Gard Combogard 3740 (Combo Basic) La Gard Combogard 6040 (39E) La Gard Combogard 66E w ith deadbolt La Gard Safeguard 3000/2441 La Gard Safeguard 3035/2441 Low e and Fletcher 3007 Low e and Fletcher 3010 Low e and Fletcher 3011 Low e and Fletcher 3012 Mauer 70076 Mauer 70077 Mauer 70079 Mauer 70091 Mauer 70092 Mauer 71111 S&G 6730 S&G 6731 SMP S520D7-C SMP S520D9-C
Mechanical key Mechanical key Electronic combination Electronic combination Electronic combination Electronic combination Mechanical combination Mechanical combination Mechanical combination Mechanical combination Electronic combination Electronic combination Electronic combination Electronic combination Electronic combination Electronic combination Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical key Mechanical combination Mechanical combination Mechanical key Mechanical key
Com m unity Safe (LPCB Ref. No. 115b/…) 5 10 11
Notes: 1. ED denote available wit up to 150mm extra depth. 2. Figures in brackets denote the volumes inlitres. The first figure is the standard volume, the second figure is the volume of safe with maximum 150mm extra depth. 3. LPS 1183: Part 1: Issue 4 is equivalent to BS EN1143-1: 1997, with the exception of the requirements for locks to meet ENV1300.
20 Nov 2011
259
PART 4: SECTION 2.2 SECURE SAFE CABINETS
The Secure safe cabinets listed in this section are approved by LPCB to EN 14450 Secure storage units Requirements, classification and methods of test for resistance to burglary - Secure safe cabinets.
Dudley Safes Limited Unit 17 Deepdale Works, Deepdale Lane, Upper Gornal, Dudley, West Midlands DY3 2AF, United Kingdom Tel: +44 (0)1384 239991 • Fax: +44 (0)1384 455129 Website: www.dudleysafes.com Certificate No: 304b to BS EN 14450: 2005
Secure Safe Cabinets Product Name
Size Reference
Harlech Lite (Level 1) Harlech Lite (Level 2)
00, 0, 1, 2, 3, 4, 5 and 6 00, 0, 1, 2, 3, 4, 5 and 6
Security Level S1 S2
Cert. No. 304b/01 304b/02
Compatible Locks
Model
Type
Security Cabinet (LPCB Ref. No. 304b/..) 01
02
Auditcon 52
Electronic Combination
Caw i 2648
Mechanical Key
Kaba 252
Electronic Combination
Kaba 525
Electronic Combination
Kaba MAS 552
Electronic Combination
LaGard 1985
Mechanical Combination
LaGard 3330
Electronic Combination
LaGard 3740
Electronic Combination
LaGard Combogard 33E
Electronic Combination
LaGard Combogard 39E
Electronic Combination
LaGard Combogard 66E
Electronic Combination
M-Locks EM3520
Electronic Combination
M-Locks EM3550
Electronic Combination
Mauer President A 71111
Mechanical Key
Opus 060/EM25.20
Electronic Combination
S&G 6730
Mechanical Combination
S&G 6731
Mechanical Combination
Godrej & Boyce Mfg. Co. Ltd. (Security Equipment Division) Plant - 17, Pirojshanagar, Vikhroli, Mumbai 400 079, India Tel: +91 22 679 64771 • Fax: +91 22 679 61509 E-mail: [email protected] or [email protected] • Website: www.godrej.com Certificate No: 954a to BS EN 14450: 2005
Secure Safe Cabinets Product Name
Model
Euro-Lite
FS10
260
External Width (mm) 325
External Height (mm) 275
External Depth (mm) 325
Weight (kg)
Security Level
Cert. No.
26
S2
954a/01
20 Nov 2011
PART 4: SECTION 2.2 SECURE SAFE CABINETS Product Name
Model FS40 FS50 FS45 FS65 FS85
External Width (mm) 450 360 490 490 490
External Height (mm) 330 430 470 660 860
External Depth (mm) 380 400 410 410 410
Weight (kg)
Security Level
40 41 56 73 91
S2 S2 S2 S2 S2
Cert. No.
Compatible Locks
Manufacturer
Model
Type
Carl Wittkopp GmbH
2648
Mechanical key lock
Carl Wittkopp GmbH
CombiStar 7250
Electronic combination
Kaba Mas Corporation
Auditcon 2
Electronic combination
Kaba Mas Corporation
Auditcon 3100
Electronic combination
Kaba Mas Corporation
SL 525
Electronic combination
Kaba Mauer GmbH
President 71111
Mechanical key lock
Kaba Mauer GmbH
Variator A 70091
Mechanical key
Kaba Mauer GmbH
Variator A 70092
Mechanical key
KG Group
EM25.20
Electronic combination
KG Group
EM30.20
Electronic combination
KG Group
EM35.20
Electronic combination
La Gard
3330-1
Mechanical combination
La Gard
Combogard 3740 (Combo Basic)
Electronic combination
La Gard
Combogard 6040 (39E)
Electronic combination
La Gard
Combogard 66E w ith deadbolt
Electronic combination
Steinbach & Vollmann GmbH & Co.
Series 4.19.92
Mechanical key lock
Alternative Brands and Models
Type
Product Name Euro-Lite
FS10
FS40
FS50
FS45
FS65
FS85
Guardian S2
FS10
FS40
FS50
FS45
FS65
FS85
EVVA
TR1000
TR4000
TR5000
TR4500
TR6500
TR8500
do it
TR1000
TR4000
TR5000
TR4500
TR6500
TR8500
Primary Alternative
Model
SMP Security Limited Halesfield 24, Telford, Shropshire TF7 4NZ, United Kingdom Tel: +44 (0)1952 585673 • Fax: +44 (0)1952 582816 E-mail: [email protected] • Website: www.smpsecurity.co.uk Certificate No: 115c to BS EN 14450: 2005
Secure Safe Cabinet Product Name
Model
Concept 2
1 2 3 4 5 6 7 1 2 3 4 5
Concept 3
20 Nov 2011
External Width (mm) 436 536 491 666 816 1010 1372 434 534 489 664 814
External Height (mm) 382 430 489 489 489 608 608 382 430 489 489 489
External Depth (mm) 382 382 482 482 482 682 682 394 394 494 494 494
Approx. Weight (kg) 34 43 50 63 75 125 162 50 62 74 92 110
Security Level S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2
Cert. No. 115c/01
115c/02
261
PART 4: SECTION 2.2 SECURE SAFE CABINETS Product Name
Model 6 7
External Width (mm) 1008 1370
External Height (mm) 608 608
External Depth (mm) 694 694
Approx. Weight (kg) 171 221
Security Level S2 S2
Cert. No.
Compatible Locks
Manufacturer
Model
Type
Product Concept 2
Concept 3
KG Group
EM25-20
Electronic combination
KG Group
EM35-20
Electronic combination
KG Group
ML67-40
Mechanical combination
LaGard
3330
Mechanical combination
LaGard
Combogard 33E1
Electronic combination
LaGard
Combogard Basic 3740
Electronic combination
LaGard
Basic Auditgard 66E
Electronic combination
LaGard
Combogard Pro 39E
Electronic combination
Low e and Fletcher
3007
Mechanical key
Low e and Fletcher
3012
Mechanical key
Mauer
70091
Mechanical key
Mauer
71111
Mechanical key
S&G
6730
Mechanical combination
Note: 1. No evidence was available to confirm these locks met the minimum lock requirements specified in Table 1 of BS EN 14450: 2005 at the time of issuing approval. None the less, the cabinets met all other requirements of BS EN 14450: 2005 and all requirements of prEN 14450: June 2004 when fitted with these locks.
262
20 Nov 2011
PART 4: SECTION 2.3 AUTOMATIC TELLER MACHINE (ATM) SAFES
Figures released by the British Bankers’ Association in March 2006 showed that there were 879 physical attacks on ATMs in 2005. That is an average of 73 per month. In that year alone, the ATM sector suffered pure cash losses of £8,574,210 - equating to an average of £23,000 per day. This represented a sharp rise in losses through ATM crime compared with previous years. Since then theft of ATM safes or money from ATM safes has not abated reinforcing the need for ATM estate mangers to ensure their ATM safes meet appropriate security standards. By selecting ATMs that incorporate a safe graded to LPS 1183 or EN 1143-1, ATM losses can be significantly reduced due to the increased time and effort required to overcome the mounting system and gain entry to the contents of the safe itself. As with free-standing safes and strongrooms, the locks fitted to the ATM safe and construction of the safe are critical. Specifiers and users should therefore discuss any proposals with their insurance company and the safe manufacturer prior to undertaking such work. Please note that the fixing system employed forms part of the over all classification assessment. As such, the use of alternative fixings or anchor systems, while generally well intentioned, may undermine the security afforded by the ATM safe and invalidate the approval. It is also important to check locking mechanisms regularly to ensure they have not been tampered with. The same rigorous approval procedures and conditions are applied to the ATM safes listed in this section as are applied to free standing safes, strongrooms and deposit safes.
20 Nov 2011
263
PART 4: SECTION 2.4 ANTI-BANDIT ATM SECURITY DEVICES
A number of ATMs have been attacked while being replenished as this is when there is the most cash held within the ATM and the cash cassettes are the most vulnerable because the door to the ATM safe is open. Products listed in this section are designed to prevent the unauthorised removal of cash cassettes from the ATM safe when the ATM safe door is open. These products have been approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free standing barriers. LPS 1175 is based on manual attack testing and currently defines eight levels of resistance to entry. These are measured in terms of attack tools and time available to the attacker. This enables specifiers to select products according to the risks that they and their property face. Due to the intended application of these products, the entry criteria used to assess these products in accordance with clause 4.3 of LPS 1175 is defined in the notes relating to each of the products listed. Although the evaluation and approval covers attempts to remove the products from the ATM safes to which they are fitted, they do not cover the attack resistance of those ATM safes.
Pressex UK Limited Kingsway South, Team Valley, Gateshead, Tyne & Wear NE11 0SH, United Kingdom Tel: +44 (0)191 497 3430 • Fax: +44 (0)191 497 3431 E-mail: [email protected] • Website: www.responsive-engineering.com Certificate No: 870a to LPS 1175: Issue 6
Anti-Bandit ATM Security Device Product Name
Compatible ATMs
Lockpoint ATM Duress Guard
NCR 84 ATM incorporating an NCR 5884 UL291 ATM safe NCR 87 ATM incorporating an NCR 5887 UL291 ATM safe
Security Rating 3
Cert. No. 870a
Notes: 1. The Lockpoint ATM Duress Guard permits access to individual cash cassettes within the ATMs listed above once the door to the ATM safe has been opened. This is possible without the need for the operator to remember an access code or use a coded key, token or other such device to operate the doors on the Lockpoint ATM Duress Guard. 2. The Lockpoint ATM Duress Guard prevents removal of individual cash cassettes from within the ATMs via the aperture created when the door to the ATM safe is opened. The level of protection against unauthorised removal of the replenished cash cassettes is expressed in the above table as a Security Rating in accordance with the requirements of LPS1175: Issue 6. The Security Rating is achieved by the Lockpoint ATM Duress Guard for up to 60 minutes after the door(s) to the compartments in which the replenished cassettes are located. This is providing the doors to the adjacent compartments have also been operated to activate the locking system on those doors. The Lockpoint ATM Duress Guard provides protection to individual replenished cash cassettes while those in adjacent compartments are being replenished at least compatible with the requirements of Security Rating 1. 3. The product’s resistance to electronic and digital attack methods, other than those possible with tools defined in LPS 1175: Issue 61 for the Security Ratings achieved, are outside the scope of this approval. 4. This approval does not cover the attack resistance of the ATM into which the Lockpoint ATM Duress Guard is fitted. However, the approval does cover the resistance to unauthorised removal of the Lockpoint ATM Duress Guard from the ATM via the aperture created when the door to the ATM safe is opened.
264
20 Nov 2011
PART 4: SECTION 2.5 DEPOSIT SAFES
Safes that incorporate a deposit facility are covered by EN 1143-2 Requirements, classification and methods of test for resistance to burglary - Part 2: Deposit systems. This describes tests over and above those specified in EN 1143-1, and includes ‘forcing’, ‘fishing’, ‘trapping’ and ‘deposit retrieval’. Deposit safes take a number of forms and these affect the classification attributed to them. Deposit safes are normally located within a building and are primarily designed to enable employees to deposit money or other items without having to open the main door of the safe. Deposit safes receive a classification of “D-#” where # is the grade of resistance achieved during testing. Deposit safes range from standard deposit safes with manual operation through to the distributed deposit systems employed by supermarkets. Night safes, on the other hand, are often accessible from the street and are primarily used by financial institutions for providing a secure depositing system for their customers. Night safes receive a classification of “N-#” where # is the grade of resistance achieved during testing.
20 Nov 2011
265
PART 4: SECTION 2.6 STRONGROOMS
Strongrooms listed in this section are approved by LPCB to one or more of the following standards:
EN 1143-1 Secure storage units. Requirements, classification and methods of test for resistance to burglary. Safes, strongroom doors and strongrooms.
LPS 1183 Specification for safe storage units. Part 1: Safes and strongrooms
Copies of LPS 1183 can be downloaded free of charge from our website www.RedBookLive.com. Strongrooms take two forms:
Cast in-situ. The strongroom structure is cast on site where there is insufficient access to manoeuvre prefabricated panels into place.
Pre-fabricated. The strongroom is formed on site from pre-fabricated panels, designed to bolt together securely to form the desired configuration.
Strongrooms are not only designed to secure larger volumes of cash and jewellery but are increasingly used to store items such as artwork and antiquities, pharmaceuticals, military equipment and highly sensitive documentation. Strongrooms are also increasingly being used to protect large scale IT server hubs due to the high value of the server equipment and business continuity risks associated with the potential loss of such equipment or data. It is important to ensure that all exposed fixings, jointing plates, the substrate into which the device is fitted and the locking mechanisms are regularly checked to ensure that they are in good condition and that they have not been tampered with. It is also important to ensure only those design options listed, such as special cable access or ventilation panels, are incorporated within the strongroom construction as the use of alternative options may undermine the level of security provided by the strongroom. Explosion (EX) Designation This designation indicates a product offers resistance to detonation of a PETN (Pentaerythritol tetranitrate) explosive charge followed by post detonation tool attacks aimed at achieving entry to the strongroom. Where the use of explosive charges is perceived to be a threat it is recommended products with this designation are selected. Core Drill (CD) Designation This designation is only applicable to strongrooms and strongroom doors achieving grades V and above. This designation reflects the ability of a product to pass the diamond drill test specified within EN 1143-1 which is designed to demonstrate the product’s superior resistance to methods of forced entry that solely involve the use of diamond core drills.
266
20 Nov 2011
PART 4: SECTION 3 SECURE OFFICE FURNITURE
Office furniture and other equipment designed to prevent unauthorised access to confidential and valuable documents are tested and certified to LPS 1228 Specification for testing and classifying the burglary resistance of office furniture. The standard was developed for the Cabinet Office as a means of specifying and testing the resistance offered by office furniture and document cabinets to unauthorised access. The standard specifies four levels of protection based on the availability of tools and time to the attacker. This enables specifiers to select the equipment that best suits their needs, such as a filing cabinet, cupboard or document safe, whilst knowing that the equipment will provide the required level of protection against unauthorised access, whether in a domestic, commercial or Government environment. The burglary resistance of the complete product is tested, including any in-situ hardware such as locks and hinges. However, no allowance is made for various stages of locking. The locks assessed as part of the evaluation of the product are listed under the ‘compatible locks’ section of each company’s entry. It is important that specifiers only select products covered by the scope detailed on the certificate as the performance of products that fall outside the scope of the assessment may not be adequate. It is also important to ensure that the products are installed in accordance with the manufacturer’s instructions and that all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly checked to ensure that they are in good condition and that they have not been tampered with. This will ensure that criminals cannot simply remove the security device to a remote location in order to gain access to the protected documentation or equipment.
20 Nov 2011
267
PART 4: SECTION 4 SECURE ENCLOSURES
Security enclosures that have been assessed to LPS 1175 Specification for testing and Classifying the Burglary Resistance of Building Components, Strongpoints and Security Enclosures are listed in this section. Each security rating is appropriate to the level of risk to forced entry or removal, and covers everything from the secure storage of tools in the domestic environment, to protection of remote equipment on railway and telecommunications infrastructures. Some examples of applications include: secure site tool and plant storage units, portable office buildings and shipping containers. The use of appropriately rated and installed physical security enclosures will protect the contents of the enclosure from the unwanted attentions of the opportunist or professional criminal. LPS 1175 is based on manual attack testing and currently defines eight levels of resistance to entry into the enclosure or removal of the enclosure from the supporting substrate. The ratings are determined in terms of attack tools and time available to the attacker, and enables specifiers to select products according to the risks that they and their property face. Unless otherwise stated, entry into the enclosures listed was determined according to the ability to pass the 400 mm by 225 mm elliptical test block defined in LPS 1175. This is considered to be a size through which a person may pass. In some cases alternative failure criteria was used during the evaluation of the enclosures listed. These were designed to suit the intended application of the enclosures concerned and the failure criteria used is noted in the relevant product entries. It is important to ensure that the enclosures are installed in accordance with the manufacturers instructions and that all exposed fixings, the substrate onto which the enclosure is fitted, and the locking mechanisms are regularly checked to ensure that they are in good condition and that they have not been tampered with. Details regarding the rating system can be found in the standard itself, copies of which are available free of charge and can be downloaded from the LPCB web site www.RedBookLive.com. It is recommended that assets such as cash or jewellery should preferably be stored in safe storage units or strongrooms approved by LPCB. These are listed in Section 2. Those looking to prevent unauthorised removal of computer equipment consider using the physical protection devices listed in Section 12.
Asgard Secure Steel Storage (a trading division of Flexiform Business Furniture Limited) 1392 Leeds Road, Bradford BD3 7AE, United Kingdom Tel: +44 (0)1274 706206 • Fax: +44 (0)1274 706247 Certificate No: 596a to LPS 1175: Issue 5
Security Enclosures Product Name Asgard Classic Secure Unit Asgard Compact Secure Unit Asgard Universal Asgard Annexe
Nominal Enclosure Height (m) 1.9 1.9 0.7 1.5
Nominal Enclosure Width (m) 1.9 1.1 0.6 1.8
Nominal Enclosure Depth (m) 0.8 0.8 0.5 0.9
Security Rating 1 1 1 1
Cert. No. 596a/01 596a/02 596a/03 596a/04
Compatible Locks
Lock
Type
Winlock HS2000
Garage door locking system fitted w ith Euro Profile 1850/05/30 single cylinder
LPCB Ref. No 596a/.. 1
2
3
4
Accessories
268
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES Accessory
LPCB Ref. No 596a/..
Tool Rail
1
2
Adjustable Shelf
3
4
Notes: 1. In order to prevent complete removal of the secure units, they must be affixed to concrete foundations in accordance with the self assembly instructions supplied with the units. 2. On products with sloping or peaked roof design, the height given is the maximum.
Bastion Security Installations Limited Finlay Court, Simonside East Industrial Estate, South Shields, Tyne and Wear NE34 9QA, United Kingdom Tel: +44 (0)191 419 3777 • Fax: +44 (0)191 497 2997 E-mail: [email protected] • Website: www.bastionprotects.com Certificate No: 1046a to LPS 1175: Issue 7
Expandable Security Enclosure Product Name
Type
Height (m)
Width (m)
Bastion Enclosure
Expanding security enclosure1 with integral entrance doorset
2.469
1.700
Length When Enclosure Is Fully Expanded (m) 2.655
Length When Enclosure Is Contracted (m) 1.700
Security Rating
Cert. No.
52
1046a/01
Compatible Doorset Locking System3
Manufacturer
Model
Tindall Engineering Mico Evo AD3 w ith Limited USCH 5
Type
Operating Devices
Three point lock w ith integrated automatic deadlock and USCH 5 cylinder guard
Internal Face
External Face
Key and lever handle
Key and lever handle
Compatible Cylinders A
Compatible Corridor Locking System4
Manufacturer
Model
Type
Operating Devices
ASSA
766 Roller Bolt
Tw o deadlocks
5
Internal Face
External Face
Com patible Cylinders
None
Key
A
Compatible Cylinders
Ref.
Manufacturer
Model
Type
A
Access2
Tigris Omega
Scandinavian Oval
Notes: 1. The enclosure may be used to house ATM’s. The resistance of ATM’s used within the enclosure is outside the scope of approval. It is the manufacturers’, and other clients’, responsibility to ensure the ATM and the aperture within which it is located cannot be exploited in order to gain entry into the enclosure. 2. The enclosure achieves a Security Rating 5 classification in the optimum locked condition, i.e. when placed in the contracted (i.e. unexpanded) position, the staples are secured with the two locks listed in the ‘compatible corridor locking systems’ table and the lock on the doorset is secured. A Security Rating 3 classification prevails in the minimum locked condition, i.e. the enclosure is expanded and the lock on the doorset is secured. 3. This lock secures the integral doorset. 4. These locks secure the enclosure into the contracted (i.e. unexpanded) position. 5. The external face of the cylinder is protected by a USCH 3 cylinder guard supplied by Tindall Engineering Limited. 6. The approval covers the enclosures when installed onto concrete bases of equivalent resistance to attack, using the method of installation defined on the ‘Installation Instructions’ drawing (Revision A, dated 3 August 2011).
20 Nov 2011
269
PART 4: SECTION 4 SECURE ENCLOSURES
Isoclad Limited 10 Alder Road, West Chirton North Industrial Estate, North Shields, Tyne & Wear NE29 8SD, United Kingdom Tel: +44 (0)191 258 5052 • Fax: +44 (0)191 259 5742 E-mail: [email protected] • Website: www.isoclad.co.uk Certificate No: 142c to LPS 1175: Issue 6
Modular Security Enclosure System Product Name
Product Type
Securiclad
Enclosure with horizontal laid panels Enclosure with vertically laid panels Enclosure with horizontal laid panels Enclosure with vertically laid panels
Minimum Height (m) 2.5
Maximum Height (m)
Minimum Width (m)
Maximum Width (m)
Minimum Depth (m)
Maximum Depth (m)
Security Rating
Cert. No.
Unlimited
2.5
Unlimited
2.5
Unlimited
3
142c/01
2.5
6.0
0.25
Unlimited
0.25
Unlimited
3
2.5
Unlimited
2.5
Unlimited
2.5
Unlimited
4
2.5
6.0
0.25
Unlimited
0.25
Unlimited
4
142c/02
System Components
Minim um Width (m) 0.25
Maximum Width (m) 1.19
Minim um Length (m) 2.5
Ceiling panel (mineral w ool)
0.25
1.19
1
6
0.1
SR3/SR4 panel (PIR)
0.25
1.19
2.5
6
0.1
Ceiling panel (PIR)
0.25
1.19
1
6
0.1
Component Type
SR3/SR4 panel (mineral w ool)
Maximum Thickness Length (m) (m) 6 0.1
Products Compatible with the Securiclad Security Panel System2,3
270
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES Manufacturer
Product Name
Ascot Doors Limited
Centurion A363S Single leaf outw ard opening doorset Centurion A363D Double leaf outw ard opening doorset Bew dley doorset Single leaf outw ard opening doorset Pow ershield Single leaf Class 3 single outw ard opening doorset Pow ershield Double leaf Class 3 double outw ard opening doorset Series 55’ level Fixed light 3’ security w indow Extendor Eclipse Collapsible grille
Benw eldSecure
Pow ershield Doors Limited
Selectaglaze Limited
Professional Barriers Limited Ascot Doors Limited
Pow ershield Doors Limited
Product Type
Centurion A355
Single leaf outw ard opening doorset Centurion A364S Single leaf outw ard opening doorset Centurion A364D Double leaf outw ard opening doorset Pow ershield Single leaf Class 4 single outw ard opening doorset Pow ershield Class 4 double
Double leaf outw ard opening doorset
LPCB Certificate Num ber
Security Rating
Compatible Locking System s Active Leaf Passive Leaf 12, 13, 15, N/A 16, 18 and 19
131d/04
3
131d/05
3
12, 13, 15, 16, 18 and 19
34, 35 and 36
746a/01
3
1
N/A
852a/01
3
2 to 11, 13,16,17 and 19
N/A
852a/02
3
2 to 11, 13,16,17 and 19
32
683a/06
3
N/A
N/A
869a/01
3
33
N/A
131d/01
4
13
N/A
131d/02
4
13, 16, 19, 27, 29 and 31
N/A
131d/03
4
13, 16, 19, 27, 29 and 31
34, 35 and 36
852a/03
4
3, 5, 7, 9, 10, 13, 16, 19, 20, 21, 22, 23, 24, 26, 28 and 30
N/A
852a/04
4
3, 5, 7, 9, 10, 13, 16, 19, 20, 21, 22, 23, 24, 26, 28 and 30
32
Compatible Locking Systems for Products Compatible with the Securiclad Security Panel System
20 Nov 2011
271
PART 4: SECTION 4 SECURE ENCLOSURES Com patible Model Locking System s 1 Assa 9787
Entry Single point mortice hook lock
Com patible Cylinders
Operation
Key
2
MICO 942-3L EPC INT AD / HSCH 3
3
MICO 942-3L EPC INT AD
4
MICO 942-3 EPC INT MD / HSCH 3
5
MICO 942-3 EPC INT MD
6
MICO 942-3P EPC INT MD / HSCH 3
7
MICO 942-3P EPC INT MD
8
MICO 942-3L EPC INT MD / HSCH 3
9
MICO 942-3L EPC INT MD
10
MICO 942-3L INT AD
11
MICO 942-3 INT 3-w ay locking system Scandinavian MD / HSCH 3 w ith manual deadlock oval cylinder w ithin the HSCH 3 cylinder guard and lever handle
12
272
Type
Exit Key via an Assa 256 (Assa Classic) combined cylinder ring and thumbturn Europrofile cylinder (key:key) and lever handle
3-w ay locking system Europrofile w ith automatic cylinder w ithin deadlocking the HSCH 3 cylinder guard and lever handle 3-w ay locking system None Europrofile w ith automatic cylinder deadlocking (key:key)and lever handle 3-w ay locking system Europrofile Europrofile w ith manual deadlock cylinder w ithin cylinder the HSCH 3 (key:key) and cylinder guard panic exit push and lever handle plate 3-w ay locking system None Europrofile w ith manual deadlock cylinder (key:key) and panic exit push plate Europrofile 3-w ay locking system Europrofile w ith manual deadlock cylinder w ithin cylinder (key:key) and the HSCH 3 push pad cylinder guard and lever handle 3-w ay locking system None Europrofile w ith manual deadlock cylinder (key:key) and push pad 3-w ay locking system Europrofile Europrofile w ith manual deadlock cylinder w ithin cylinder the HSCH 3 (key:key) and cylinder guard lever handle and lever handle 3-w ay locking system None Europrofile w ith manual deadlock cylinder (key:key) and lever handle 3-w ay locking system None Scandinavian w ith automatic oval cylinder and deadlocking lever handle Scandinavian oval cylinder and panic exit push plate
Q or R
A, B, C, D, E or F
-
A, B, C, D, E or F
-
A, B, C, D, E or F
-
A, B, C, D, E or F
-
-
G, H, I, J, K, L, M, N or P G
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES 13
14
15
16
17
18
MICO 942-3 INT 3-w ay locking system None MD w ith manual deadlock
Scandinavian oval cylinder and panic exit push plate MICO 942-3P INT 3-w ay locking system Scandinavian Scandinavian MD / HSCH 3 w ith manual deadlock oval cylinder oval cylinder w ithin the HSCH and push pad 3 cylinder guard and lever handle
20
MICO 942-3L EPC INT AD / HSCH 4
23
G
Scandinavian oval cylinder and push pad MICO 942-3L INT 3-w ay locking system Scandinavian G, H, I, J, K, L, Scandinavian MD / HSCH 3 w ith manual deadlock oval cylinder M, N or P oval cylinder w ithin the HSCH and lever handle G 3 cylinder guard and lever handle MICO 942-3L INT 3-w ay locking system None MD w ith manual deadlock
22
G, H, I, J, K, L, M, N or P
MICO 942-3P INT 3-w ay locking system None MD w ith manual deadlock
19
21
-
3-w ay locking system Europrofile w ith automatic cylinder w ithin deadlocking the HSCH 4 cylinder guard and lever handle MICO 942-3 EPC 3-w ay locking system Europrofile INT MD / HSCH 4 w ith manual deadlock cylinder w ithin the HSCH 4 cylinder guard and lever handle MICO 942-3P 3-w ay locking system Europrofile EPC INT MD / w ith manual deadlock cylinder w ithin HSCH 4 the HSCH 4 cylinder guard and lever handle MICO 942-3L 3-w ay locking system Europrofile EPC INT MD / w ith manual deadlock cylinder w ithin HSCH 4 the HSCH 4 cylinder guard and lever handle
20 Nov 2011
Scandinavian oval cylinder and lever handle Europrofile cylinder (key:key) and lever handle Europrofile cylinder (key:key) and panic exit push plate Europrofile cylinder (key:key) and push pad Europrofile cylinder (key:key) and lever handle
-
A, B, C, D, E or F
A, B, C, D, E or F
A, B, C, D, E or F
A, B, C, D, E or F
273
PART 4: SECTION 4 SECURE ENCLOSURES 24
25
26
27
28
29
30
31
32
MICO 942-3L INT 3-w ay locking system Scandinavian G, H, I, J, K, L, Scandinavian AD / HSCH 4 w ith automatic M, N or P oval cylinder oval cylinder deadlocking w ithin the HSCH and lever handle G 4 cylinder guard and lever handle Scandinavian oval cylinder and panic exit push plate
G, H, I, J, K, L, M, N or P
MICO 942-3P INT 3-w ay locking system Scandinavian Scandinavian MD / HSCH 4 w ith manual deadlock oval cylinder oval cylinder w ithin the HSCH and push pad 4 cylinder guard and lever handle
G, H, I, J, K, L, M, N or P
MICO 942-3 INT 3-w ay locking system Scandinavian MD / HSCH 4 w ith manual deadlock oval cylinder w ithin the HSCH 4 cylinder guard and lever handle
G
G
MICO 942-3L INT 3-w ay locking system Scandinavian Scandinavian G, H, I, J, K, L, MD / HSCH 4 w ith manual deadlock oval cylinder oval cylinder M, N or P w ithin the HSCH and lever handle G 4 cylinder guard and lever handle M0455
-
-
33
Surface mounted barrel bolts Extendor Eclipse CL03 w ith CL03 cylinder guard
Key (w hen internal locking version only)
34
MICO 942
Europrofile cylinder w ithin the CL03 cylinder guard -
35
MICO 942P
36
MICO 942L
2-w ay panic exit device 2-w ay emergency exit device 2-w ay emergency exit device
S, T or U
Panic bar
-
Push pad
-
Lever handle
-
Compatible Cylinders for Products Compatible with the Securiclad Security Panel System
Cylinder Reference A B C D E F G H I J K
Manufacturer Model
Type
Abloy Abloy ASSA ASSA ASSA Kaba ASSA ASSA ASSA ASSA Abloy
Protec CY304 Disclock Pro CY304 Tw in 7622 C5822 4822 Quattro S Euro 4807 Tw in 7607 C5807 4407 Protec CY201PT
Double Europrofile cylinder (key:key) Double Europrofile cylinder (key:key) Double Europrofile cylinder (key:key) Double Europrofile cylinder (key:key) Double Europrofile cylinder (key:key) Double Europrofile cylinder (key:key) Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder
L M N O P Q R S T U
Locken Kaba Kaba Abloy ASSA ASSA ASSA ASSA CISA Kaba
CL-PL2WR Quattro S Oval K20 Oval Disclock Pro CY201DP 4801 C5801 C5803 dp4400 AP3S Quattro Plus
Half Scandinavian oval mechatronic cylinder Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder Half Scandinavian oval mechanical cylinder Single Europrofile cylinder (key) Single Europrofile cylinder (key) Single Europrofile cylinder (key)
274
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES Notes: 1. The Securiclad panel systems must be installed in accordance with the approved Securiclad design manual (ISO/SECG04/02/11) and compatible product list (ISO/SEC/DSP/15/9/10). 2. The Security Rating attributed to the compatible product must be at least that of the enclosure in which it is to be fitted. For example, a Security Rating 3 doorset shall not be used to form part of a Security Rating 4 enclosure. 3. Refer to notes contained within the relevant certificate/Red Book entries for these products for details of restrictions on their use.
Liddle Doors Limited Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698 E-mail: [email protected] • Website: www.liddledoors.co.uk Certificate No: 442e to LPS 1175: Issue 6
Security Cabinet (Wall Mounted) Product Name
Model
Liddle Series 2 Security Box
Size 1 wall mounted security cabinet Size 2 wall mounted security cabinet Size 1 wall mounted security cabinet Size 2 wall mounted security cabinet
Liddle Series 3 Security Box
Nominal Cabinet Height (mm) 400
Nominal Cabinet Width (mm) 460
Nominal Cabinet Depth (mm) 240
Security Rating 2
400
400
150
2
400
460
240
3
400
400
150
3
Cert. No. 442e/01
442e/02
Compatible Padlocks
Padlock Designation
Cylinder
LPCB Ref. No 442e/
Abloy PL340/25
Abloy Disklock Pro
1
2
Notes: 1. The security boxes are approved when wall mounted directly to brickwork, concrete or steel. The approval does not cover the security boxes when mounted to alternative substrates or via intermediate substrates such as plasterboard. 2. Certification does not cover the use of padlocks other than those listed above. Utilisation of unlisted padlocks may affect the level of security offered by the product.
Lowrey Contractors Limited 200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111 E-mail: [email protected] • Website: www.lowrey-contractors.co.uk Certificate No: 974b to LPS 1175: Issue 7
Modular Security Cage System Product Name
Type
Lowrey Level 1 Security Mesh Panel System Lowrey Level 2 Security Mesh Panel System
Cage formed from four sides and a ceiling Cage formed from four sides and a ceiling
20 Nov 2011
Minimum Height (m) 1.1
Maximum Height (m) 3.91
Minimum Width (m)1 0.5
Maximum Width (m)
1.1
3.91
0.5
Maximum Depth (m) 4.0
Security Rating
Cert. No.
Unlimited
Minimum Depth (m) 0.5
1
974b/01
Unlimited
0.5
4.0
2
974b/02
275
PART 4: SECTION 4 SECURE ENCLOSURES Product Name
Type
Lowrey Level 3 Security Mesh Panel System
Cage formed from four sides and a ceiling
Minimum Height (m) 1.1
Maximum Height (m) 3.91
Minimum Width (m)1 0.5
Maximum Width (m)
Minimum Depth (m) 0.5
Unlimited
Maximum Depth (m) 4.0
Security Rating
Cert. No.
3
974b/03
System Components
Com ponent
Wall panel
Mesh w all panel
Minimum Height (m ) 0.25
Roof panel
Mesh roof panel
N/A
N/A
0.25
1.5
0.25
3.8
Support post
Support post for w alling system 270 degree corner post for w alling system 90 degree corner post for w alling system Single leaf outw ard opening doorset Double leaf outw ard opening doorset
1.0
3.8
0.215
0.215
N/A
N/A
1.1
3.91
0.125
0.125
N/A
N/A
1.1
3.91
0.11
0.11
N/A
N/A
Corner post
Doorsets
Type
Maximum Height (m ) 2.4
Minimum Width (m ) 0.5
Maximum Width (m ) 1.5
Minim um Length (m) N/A
Maximum Length (m) N/A
Refer to ‘Low rey Level 1, 2 and 3’ single leaf mesh security doorsets (LPCB Ref. No. 974a/01, 03 and 05) for scope of approval. Refer to ‘Low rey Level 1, 2 and 3’ double leaf mesh security doorsets (LPCB Ref. No. 974a/02, 04 and 06) for scope of approval.
Notes: 1. The minimum width of an enclosure wall incorporating a doorset is 0.63 m. 2. The cage’s resistance relies on the supporting substrate offering compatible resistance to manual attack. 3. The Lowrey security mesh panel system is approved when installed in accordance with the instructions detailed on Lowrey’s document E-INST001 (Issue 3). Certificate No: 974e to LPS 1175: Issue 7
Modular Security Enclosure System Product Name
Product Type
Lowrey Level 4 Security Solid Panel System
Enclosure formed from four sides and a ceiling
Minimum Height (m) 1.1
Maximum Height (m) 3.91
Minimum Width (m)1 0.5
Maximum Width (m)
Minimum Depth (m)
Maximum Depth (m)
Security Rating
Cert. No.
Unlimited
0.5
4.0
4
974e/01
System Components
276
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES Component
Maxim um Height (m ) 2.4
Minim um Width (m ) 0.5
Maxim um Width (m ) 1.5
Minim um Length (m ) N/A
Maxim um Length (m ) N/A
Wall panel
Solid w all panel
Minimum Height (m ) 0.25
Roof panel
Solid roof panel
N/A
N/A
0.25
1.5
0.25
3.8
Support post
Support post for w alling system 270 degree corner post for w alling system 90 degree corner post for w alling system Single leaf outw ard opening plain leaf doorset Double leaf outw ard opening plain leaf doorset
1.0
3.8
0.215
0.215
N/A
N/A
1.1
3.91
0.125
0.125
N/A
N/A
1.1
3.91
0.11
0.11
N/A
N/A
Corner post
Doorsets
Type
Refer to ‘Low rey Level 4’ single leaf security doorsets (LPCB Ref. No. 974d/01) for scope of approval. Refer to ‘Low rey Level 4’ double leaf security doorsets (LPCB Ref. No. 974d/02) for scope of approval.
Notes: 1. The minimum width of an enclosure wall incorporating a doorset is 0.63 m. 2. The enclosures resistance relies on the supporting substrate offering compatible resistance to manual attack. 3. The Lowrey security solid panel system is approved when installed in accordance with the instructions detailed on Lowrey’s document E-INST001 (Issue 3).
Morgan Marine Limited Llandybie, Ammanford, Carmarthenshire SA18 3GY, United Kingdom Tel: +44 (0)1269 850437 • Fax: +44 (0)1269 850656 E-mail: [email protected] • Website: www.morgan-marine.com Certificate No: 1051a to LPS 1175: Issue 7
Security Enclosures Product Name
Product Type
Nominal Minimum Height1 (m)
Nominal Maximum Height1 (m)
Nominal Minimum External Width (m)
Nominal Maximum External Width (m)
Morgan Titan SR2 Morgan Titan SR3
GRP security enclosure GRP security enclosure
2.21
5.0
1.02
2.21
5.0
1.02
Nominal Maximum External Length (m)
Security Rating
Cert. No.
14.0
Nominal Minimum External Length (m) 1.02
30.0
2
1051a/01
14.0
1.02
30.0
33
1051a/02
Compatible Doorsets
Manufacturer Model
Type
PSF Wales Limited PSF Wales Limited
Single leaf outw ard opening hinged doorset Double leaf outw ard opening hinged doorset
Hercules SAF3 Hercules SAF3
Structural Structural Opening Opening Height (m ) Width (m ) 2.12
1.12
2.21
2.21
Com patible Locking Systems Active Passive Leaf Leaf 1 and 2 N/A 1 and 2
3
LPCB Ref. No.
953a/01 953a/02
Locking Options Available on the Compatible Doorsets
20 Nov 2011
277
PART 4: SECTION 4 SECURE ENCLOSURES Com patible Manufacturer Locking System 1 Tindall Engineering
2
Tindall Engineering
3
Commercial Body Fittings Limited
Model / Type
Operation Entry
Mico 942-3L INT AD / USCH4 three-point auto-deadlocking autobolting system w ith external cylinder access Mico 942-3L INT MD / USCH4 three-point manual-deadlocking auto-bolting system w ith external cylinder access Sprung tow er bolt
USCH4 cylinder guard incorporating a Scandinavian oval cylinder USCH4 cylinder guard incorporating a Scandinavian oval cylinder -
Com patible Cylinders
Exit Thumbturn and lever handle
A to G
Thumbturn and lever handle
A to G
Tw o sprung tow er bolts 3
N/A
Cylinders Options
Cylinder Reference A
Manufacturer
Model
Type
Abloy
Disclock Pro CY201DP Mechanical Scandinavian oval cylinder
B
Assa
4807
Mechanical Scandinavian oval cylinder
C
Assa
C5807
Mechanical Scandinavian oval cylinder
D
Assa
Tw in 7607
Mechanical Scandinavian oval cylinder
E
Kaba
K20 Oval
Mechanical Scandinavian oval cylinder
F
Kaba
Quattro S Oval
Mechanical Scandinavian oval cylinder
G
Locken
CL-PL2WR
Mechatronic Scandinavian oval cylinder 4
Approved Optional Design Features
Optional Design Feature
Associated Draw ing Reference
Removable roof
MDS017
Shrouded vents w ith cow ls measuring 0.45 m w ide by 0.45 m high by 0.45 m deep5,6
MDS015 (Sheet 2)
Revision / Date C 22/7/11 F 22/7/11
Notes: 1. The height is measured from the ground to the underside of the roof panel. 2. This is the minimum length/width of the enclosure when the enclosure does not incorporate a doorset in that plane. The minimum length/width of the enclosure when it incorporates a doorset within that plane is 1.39 m (single leaf doorset fitted) or 2.39 m (double leaf doorset fitted). 3. The Morgan Titan SR3 enclosures incorporating double leaf doorsets achieve Security Rating 3 when both sprung tower bolts on the passive leaf are engaged and the lock mechanism fitted to the primary leaf is engaged and deadlocked. A Security Rating 1 classification prevails if one of the sprung tower bolts on the passive leaf is not engaged. 4. The resistance of the electronic cylinder to ‘non-mechanical’ attack is outside the scope of this approval because it is outside the scope of LPS1175: Issue 7. Likewise, this approval does not cover the possible effects of any susceptibilities relating to the functionality and performance of the keys that may be used to operate the cylinder. It is therefore recommended that specifiers and installers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse and are resistant to any environmental conditions/interference that may cause the lock to disengage. 5. The approval does not cover the provision of any other apertures within the fabric of the enclosure, e.g. for ventilation or other services, other than that provided by the shrouded vent listed in the list of approved optional design features. 6. The shrouded vents must be located at least 0.3 m away from the thumbturns and lever handles present on Hercules SAF3 doorsets when fitted within the same plane as the doorset, and 0.4 m away from the thumbturns and lever handles present on Hercules SAF3 doorsets when located in a wall that is perpendicular to the plane of the doorset. 7. The approval covers the enclosures when installed onto stepped concrete bases of equivalent resistance to attack, using the method of installation defined on drawing MDS 015 (Revision F dated 22 July 2011).
278
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES
Professional Barrier Systems Limited 16 Stapledon Road, Orton Southgate, Peterborough PE2 6TD, United Kingdom Tel: +44 (0)1733 361511 • Fax: +44 (0)1733 361512 E-mail: [email protected] • Website: www.extendor.co.uk Certificate No: 869b to LPS 1175: Issue 6
Modular Security Cages Product Name
Type
Extendor Eclipse
Modular cage formed from Extendor Eclipse fixed and opening grilles1
Minimum Height (m) 0.715
Maximum Height (m)
Minimum Width (m)
Maximum Width (m)
3.673, 4
0.48
Unlimited2, 5
Minimum Length (m) 1.0
Maximum Length (m) Unlimited2, 5
Security Rating
Cert. No.
3
869b/01
System Components
Com ponent Type
Wall panel4 Roof panel Doorset7
Minim um Height (m ) 0.625
Maxim um Height (m ) 3.58
Minimum Width (m ) 0.3
N/A
N/A
0.625
2.7
Maximum Width (m ) 3.06
Minim um Length (m) N/A
Maximum Length (m) N/A
0.3
3.06
0.625
3
1
3.025
N/A
N/A
Notes: 1. Cages are rectilinear in plan and not limited to a simple rectangle. That is approval covers cages with acute and obtuse vertical corners. 2. The maximum sizes of the cage are subject to specific assessment of physical restrictions and operational conditions. 3. The maximum height of any opening sash within the cage is 2.7 m. Cages above this height incorporate a fixed grille. 4. Wall panels can be coupled vertically to form cage height. 5. The maximum clear span is 4 m. Spans greater than this require support column(s). 6. For details of locking options and accessories approved refer to certificate 869a/01. 7. The certification covers the installation of the cage directly to a concrete floor8. 8. The cages can also be secured onto raised floors. This is providing the cage extends under the raised floor to a concrete floor beneath it. The wall panels located under the raised floor shall be bolted to the underside of the wall panels located above the floor, sandwiching the floor panels between them. The wall panels located under the raised floor shall also be directly fixed to the concrete floor beneath the cage.
PSF Wales Limited Llys Rhiannon, Cil Yr Ychen Industrial Estate, Landeilo Road, Llandybie, Ammanford, Carmarthenshire SA18 3GY, United Kingdom Tel: +44 (0)1269 851777 • Fax: +44 (0)1269 851747 E-mail: [email protected] • Website: www.psfwales.co.uk Certificate No: 953b to LPS 1175: Issue 6
20 Nov 2011
279
PART 4: SECTION 4 SECURE ENCLOSURES Modular Security Enclosures Product Name
Product Type
Hercules SAF 3
Modular enclosure with single leaf outward opening doorset1 Modular enclosure with double leaf outward opening doorset2 Modular enclosure with single leaf outward opening doorset3 Modular enclosure with double leaf outward opening doorset4
Hercules SAF 4
Nominal Minimum External Height (m) 2.3
Nominal Maximum External Height (m)
Nominal Minimum External Width (m)
Nominal Maximum External Width (m)
Nominal Minimum External Depth (m)
Nominal Maximum External Depth (m)
Security Rating
Cert. No.
3.8
1.73
25
1.0
10
3
953b/01
2.3
3.8
2.78
25
1.0
10
3
953b/02
2.3
3.8
1.73
25
1.0
10
4
953b/03
2.3
3.8
2.78
25
1.0
10
4
953b/04
Approved Accessories
Accessory
Hercules SAF 3 and 4 Enclosure (LPCB Ref. No. 953b/..) 01
02
03
04
Shrouded vents (200 mm high by 350 mm w ide)5
Fixed roof
Removable roof
Notes: 1. The approval covers the use of the Hercules SAF 3 single leaf doorsets (LPCB reference number 953a/01). 2. The approval covers the use of the Hercules SAF 3 double leaf doorsets (LPCB reference number 953a/02). 3. The approval covers the use of the Hercules SAF 4 single leaf doorsets (LPCB reference number 953a/03). 4. The approval covers the use of the Hercules SAF 4 double leaf doorsets (LPCB reference number 953a/04). 5. The vents shall not be located within 1.2 m of the locks on doorsets fitted to the enclosure. 6. The approval covers the Hercules SAF 3 and 4 enclosures when installed in accordance with the ‘Installation instructions for Hercules SAF kiosk’ dated 2 February 2010. Certificate No: 953c to LPS 1175: Issue 7
Security Enclosures Product Name
Product Type
Hercules SAF 2
Security enclosure with integral single or double leaf1 padlockable doorset
Nominal Minimum External Height (m) 0.8
Nominal Maximum External Height (m)
Nominal Minimum External Width (m)
Nominal Maximum External Width (m)
Nominal Minimum External Depth (m)
Nominal Maximum External Depth (m)
Security Rating
Cert. No.
2.8
0.63
2.8
0.375
2.8
22
953c/01
Compatible Padlocks
280
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES
Manufacturer
Model
Cylinder
Abloy
PL340/25 DP
Abloy Disclock Pro
Abloy
PL340/25 PT
Abloy Protec
Abloy
PL342 DP
Abloy Disclock Pro
Abloy
PL342 PT
Abloy Protec
Accessories
Type
Description
Shrouded vent w ith integrated vermin mesh.
The shroud has external dimensions 300 mm (major height) by 200 mm (minor height) by 356 mm (w idth) by 100 mm (depth). It incorporates a 56 mm w ide by 312 mm long ventilation slot in the bottom fitted w ith a 100 mm by 100 mm vermin mesh.
Notes: 1. The scope of approval covers doorsets formed with leafs of widths between 0.35 m and 1.3 m and heights between 0.7 m and 2.8 m secured using the padlocks listed in the compatible padlock section. 2. The security rating on the double doorset version of the security enclosure is achieved when both bolts on the passive leaf are engaged, the multi-point lock mechanism fitted to the primary leaf engaged and padlocked using one of the padlocks listed in the compatible padlock section. The double doorset version of the security enclosure achieved Security Rating 1 if only one of the tower bolts on the passive leaf was engaged. 3. The approval does not cover the provision of any apertures within the enclosure fabric, other than the integral doorset or the shrouded vent described in the accessories section. 4. The approval covers the Hercules SAF 2 pre-fabricated security enclosures when installed directly onto a concrete plinth in accordance with the instructions contained on PSF Wales Limited’s document SR2 K2 dated 29 March 2011.
R & D Sheetmetal Limited Unit 1A, Victoria Court, Colliers Way, Clayton West, Huddersfield, West Yorkshire HD8 9TR, United Kingdom Tel: +44 (0)1484 864886 • Fax: +44 (0)1484 866505 E-mail: [email protected] • Website: www.randdsheetmetal.co.uk Certificate No: 1034a to LPS 1175: Issue 7
Modular Security Enclosure Product Name
Product Type
Security Evo IV
Enclosure formed from four sides and a ceiling Enclosure formed from four sides and a ceiling Enclosure formed from four sides and a ceiling
Security Evo V Security Evo VI
Minimum Height (m) 1.9
Maximum Height (m)
Minimum Width (m)
Maximum Width (m)
Minimum Depth (m)
Maximum Depth (m)
Security Rating
Cert. No.
2.7
1.1
2.4
0.8
Unlimited
4
1034a/01
1.9
2.7
1.1
2.4
0.8
Unlimited
5
1034a/02
1.9
2.7
1.1
2.4
0.8
Unlimited
6
1034a/03
System Components
20 Nov 2011
281
PART 4: SECTION 4 SECURE ENCLOSURES Com ponent
Type
Minimum Height (m ) 1.8
Maxim um Height (m ) 2.35
Minimum Width (m ) 0.25
Maximum Width (m ) 1.1
Minim um Depth (m) N/A
Maximum Depth (m) N/A
Wall panel
Wall panel
Roof panel
Single roof panel
0.1
0.35
1.1
2.4
0.8
1.05
End roof panel
0.1
0.35
1.1
2.4
0.25
1.05
Mid roof panel
0.1
0.35
1.1
2.4
0.25
1.1
1.8
2.35
0.1
0.35
N/A
N/A
Corner post
Corner post
Doorsets 1
Single leaf outw ard opening doorset
Refer to Security Evo doorset range (LPCB Ref. No. 1034b) for scope of approval.
Notes: 1. Certification does not cover the use of locks other than those listed for use with the relevant R&D Sheetmetal Limited doorset. Utilisation of unlisted locks may affect the level of security offered by the doorset fitted to the enclosure. 2. The enclosure’s resistance relies on the supporting substrate offering compatible resistance to manual attack. 3. The Security Evo enclosure system is approved when installed in accordance with the instructions detailed on document EVO-INST01 (Issue 3) and the general arrangement drawings supplied with the product.
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Certificate No: 450b to LPS 1175: Issue 5
Security Cabinets Product Name Half Location Apparatus Case (LAC/H) Full Location Apparatus Case (LAC/F) Half Location Apparatus Case (LAC/H) Full Location Apparatus Case (LAC/F)
Nominal Enclosure Height (mm) 1850
Nominal Enclosure Width (mm) 575
Nominal Enclosure Depth (mm) 535
Security Rating 3
Cert. No. 450b/01
1850
1010
535
3
450b/02
1850
575
535
4
450b/03
1850
1010
535
4
450b/04
Compatible Padlocks
Padlock Designation Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy
282
PL240/25 PL240/25EX PL240/25DP PL240/25PT PL242 PL242EX PL242DP PL242PT PL250/25 PL250/25EX PL250/25DP PL250/25PT PL340 PL340EX PL340DP
Cylinder Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy
High profile Exec Disklock Pro Protec High Profile Exec Disklock Pro Protec High Profile Exec Disklock Pro Protec High Profile Exec Disklock Pro
1
LPCB Ref. No 450b/… 2 3
4
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES Abloy PL340PT Abloy PL342 Abloy PL342EX Abloy PL342DP Abloy PL342PT Abloy PL350/25 Abloy PL350/25EX Abloy PL350/25DP Abloy PL350/25PT Chubb 1K23c Kaba KP15.0000C5-RB Kaba K20SS65L Kaba K20SS65CL Rotalok 60/12/SE Rotalok 60/12/SE Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST-T027 Rotalok 60/12/ST Rotalok 60/12/ST
Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Chubb 6-pin Kaba 20 (Armoured)3 Kaba 20 (Armoured) 3 Kaba 20 (Armoured) 3 Kaba 20 (Armoured) 3 Kaba 20 (Standard) 3 Abloy Disklock Pro Abloy Exec Abloy Protec Assa Tw in-Combi Kaba 20 (Armoured) 3 Kaba 20 (Standard) 3
Notes: 1. Certification does not cover the use of padlocks other than those listed above. Utilisation of unlisted padlocks may affect the level of security offered by the enclosure. 2. The ‘user friendliness’ of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS1175: Issue 5. 3. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders. Certificate No: 450c to LPS 1175: Issue 5
Modular Security Cabinets and Building Systems Product Name
Product Type
WMC/DV4
Walk-In Modular Building System Small modular secure cabinet system with single leaf doorset Small modular secure cabinet system with double leaf doorset Walk-in modular building system Small modular secure cabinet system with single leaf doorset Small modular secure cabinet system with double leaf doorset
CB1/DV4
CB2/DV4
WMC/DV3
CB1/DV3
CB2/DV3
Minimum Height (mm) 1500
Maximum Height (mm) 3000
Minimum Width (mm) 1000
Maximum Width (mm) 5000
Minimum Depth (mm) 1000
Maximum Depth (mm) 10000
Security Rating
Cert. No.
4
450c/01
900
2000
650
5000
450
1500
4
450c/02
900
2000
1350
5000
450
1500
4
450c/03
1500
3000
1000
4000
1000
10000
3
450c/04
900
2000
650
5000
450
1500
3
450c/05
900
2000
1350
5000
450
1500
3
450c/06
System Components
20 Nov 2011
283
PART 4: SECTION 4 SECURE ENCLOSURES
Com ponent Type
Wall panels
Roof panels
Doorsets 1
Minim um Maxim um Minimum Maxim um Minimum Maximum Height Width Depth Depth Height Width (m m) (mm ) (m m ) (m m ) (m m) (mm )
Side panel 900 3000 450 1200 N/A N/A Side corner panel 900 3000 450 1200 N/A N/A Single piece side 900 2000 650 1800 450 1025 panel2 Capping panel3 150 2100 500 2600 N/A N/A "Security Rating 4" N/A N/A 450 1200 510 5060 central roof panel "Security Rating 3" N/A N/A 450 1200 510 4060 central roof panel "Security Rating 4" N/A N/A 450 1200 510 5060 end roof panel "Security Rating 3" N/A N/A 450 1200 510 4060 end roof panel 'One piece' roof N/A N/A 510 1200 710 5060 panel For dimensions, please refer to UltraSecure DS1/DV4 doorset (LPCB Ref. Single leaf outw ard opening No. 450a/03) doorset
LPCB Ref No: 450c/…
01 02 03 04 05 06
Double leaf outw ard opening doorset
For dimensions, please refer to UltraSecure DS2/DV4 doorset (LPCB Ref. No. 450a/08)
Single leaf outw ard opening doorset
For dimensions, please refer to UltraSecure DS1/DV3 doorset (LPCB Ref. No. 450d/01)
Single leaf outw ard opening doorset
For dimensions, please refer to UltraSecure DS1/LS3 doorset (LPCB Ref. No. 450d/02)4
Double leaf outw ard opening doorset
For dimensions, please refer to UltraSecure DS2/DV3 doorset (LPCB Ref. No. 450d/03)
Approved Accessories
Accessory Louvre vents 5 Ultrasecure DV single, tw in or triple leaf access covers 6
01
02
LPCB Ref. No. 450c/… 03 04 05
06
Notes: 1 Certification does not cover the use of locks other than those listed for use with the relevant Technocover doorsets (LPCB Ref. No’s. 450a/03 and 08, and 450d/01, 02 and 03). Utilisation of unlisted locks may affect the level of security offered by the doorset(s) fitted to the cabinet. 2 Combined maximum size of panel is restricted by material availability. Refer to manufacturer before ordering. 3 The following constraints apply to capping panel: a. If the panel height is less than 1200 mm, the maximum panel width is 2600 mm. b. If the panel height is greater than 1200 mm, the maximum panel width is 1200 mm. 4 The following constraints apply when the UltraSecure DS1/LS3 door is fitted to CB1 cabinets or WMC modular buildings: a. Cabinet depth shall be at least 800 mm. b. Cabinet height shall be at least 1200 mm. c. Minimum distance on width side from leading edge of door leaf to side of cabinet is 625 mm. 5 A maximum of six louvre vents may be fitted to each panel. 6 The access covers fall within the scope of LPCB Ref. No’s. 450a/01, 02, 04, 05, 06 and 07. However, the maximum internal opening width is restricted to 1100 mm. Certificate No: 450i to LPS 1175: Issue 7
284
20 Nov 2011
PART 4: SECTION 4 SECURE ENCLOSURES Modular Security Cage System Product Name
Product Type
Ultrasecure security cage system
Cage formed from one side and a ceiling supported by existing adjacent walls Cage formed from two sides supported by existing adjacent walls Cage formed from two sides and a ceiling supported by existing adjacent walls Cage formed from three sides supported by existing adjacent walls Cage formed from three sides and a ceiling supported by existing adjacent walls Cage formed from three sides supported by existing adjacent walls Cage formed from four sides and a ceiling
Minimum Height (m) 0.501
Maximum Height (m) 6
Minimum Width (m) 0.502
Maximum Width (m) Unlimited
Minimum Depth (m) 0.502
Maximum Depth (m) 6
Security Rating
Cert. No.
3
450i/01
0.501
6
0.632
Unlimited
0.632
Unlimited
3
0.501
6
0.632
Unlimited
0.632
6
3
0.501
6
0.762
Unlimited
0.632
Unlimited
3
0.501
6
0.762
Unlimited
0.632
6
3
0.501
6
0.762
Unlimited
0.632
Unlimited
3
0.501
6
0.762
Unlimited
0.762
6
3
System Components
Com ponent
Wall panel Roof panel Corner post Support post Doorsets
Type
Mesh w all panel Mesh roof panel Corner post for cage system Support post for cage system Single leaf outw ard opening doorset Double leaf outw ard opening doorset
Minimum Height (m ) 0.50 N/A 0.50
Maximum Height (m ) 6 N/A 6
Minim um Width (m) 0.25 0.25 0.13
Maximum Width (m) 1 1 0.13
Minim um Length (m) N/A 0.50 N/A
Maximum Length (m) N/A 6 N/A
0.46
5.91
0.165
0.165
N/A
N/A
Refer to Ultrasecure SCD1 mesh security doorset (LPCB Ref. No. 450j/01) for scope of approval. Refer to Ultrasecure SCD2 mesh security doorset (LPCB Ref. No. 450j/02) for scope of approval.
Notes: 1. The minimum height of enclosures incorporating a doorset is 1.08 m. 2. The minimum length of a side wall incorporating doorsets is 0.63 m. 3. The cage’s resistance relies on the supporting substrate offering compatible resistance to manual attack. 4. The Ultrasecure security cage system is approved when installed in accordance with the instructions detailed on document SCS-DV3-FIT-01 (Ref.B).
20 Nov 2011
285
PART 4: SECTION 4 SECURE ENCLOSURES
Trimetals Limited Sunrise Business Park, Higher Shaftesbury Road, Blandford Forum, Dorset DT11 8ST, United Kingdom Tel: +44 (0)1258 459441 • Fax: +44 (0)1258 480408 E-mail: [email protected] • Website: www.trimetals.co.uk Certificate No: 899a to LPS 1175: Issue 6
Bicycle and Motorcycle Store Product Name
Type
Model
Protect a Cycle Protect a Bike
Bicycle store Motorcycle store Motorcycle store Motorcycle store
Standard pent roof model Wide pent roof model Extra wide pent roof model
Nominal Internal Height1 (m) 1.28 2.0 2.0 2.0
Nominal Internal Width (m) 1.8 1.4 1.6 1.7
Nominal Internal Depth (m) 0.84 2.7 2.7 2.7
Security Rating
Cert. No.
12 23 23 23
899a/01 899a/02
Compatible Locking Devices
Product Name
Locking Device
Manufacturer
Model
Description
Protect a Cycle
Ground anchor 4
Oxford Products Limited Oxford Products Limited IR Safety and Security Oxford Products Limited Oxford Products Limited
Oxford BruteForce (OF439) Oxford HD Mini (OF161)
Ground anchor
7 ft KryptoFlex Looped Cable (210610) Oxford RotaForce (OF438) Oxford Hardcore XL (OF118)
10 mm diameter by 2.2 m double looped security cable Ground anchor
Padlock4 Security cable4 Protect a Bike
Ground anchor 5 Chain/padlock5
Mini ‘U-lock’ padlock
Security chain and padlock set
Approved Installation Configurations
Product Name
Configuration
Protect a Cycle
Mounted directly onto a flat level concrete surface at least 100 mm thick, in accordance w ith the ‘Protect a cycle assembly instructions’ (Issue 1 dated 6 October 2008) Mounted directly onto a flat level concrete surface at least 100 mm thick, in accordance w ith the ‘Pent roof shed assembly instructions’
Protect a Bike
Notes: 1. This is the enclosure’s nominal internal height at the peaked section of the roof. 2. The security rating relates to resistance to removal of complete bicycles, of designs incorporating enclosed frames (e.g. ‘diamond’, ‘parallel top tube’, ‘single diagonal’, ‘mixte’ and ‘berceau’), that are secured within the ‘Protect a cycle’ bicycle store in accordance with the ‘Protect a cycle assembly instructions’ (Issue 1 dated 6 October 2008). 3. The security rating relates to resistance to removal of complete motorcycles that are secured within the ‘Protect a bike’ motorcycle store in accordance with the ‘Trimetals Titan Range roof shed assembly instructions’. 4. These locking devices must always be used to secure the bicycles within the security enclosure in order to achieve the security rating attributed to the ‘Protect a Cycle’ bicycle store. The cable should be passed through the centre of the bicycle frame and looped through the ground anchor and the two looped ends of the cable should both be secured using the padlock provided, as illustrated in ‘step 15’ of the ‘Protect a cycle assembly instructions’ (Issue 1 dated 6 October 2008). 5. These locking devices must always be used to secure the motorcycles within the security enclosure in order to achieve the security rating attributed to the ‘Protect a Bike’ motorcycle store. The chain should be passed through either the motorcycle frame or rear wheel and looped through the ground anchor and the two looped ends of the chain should both be secured using the padlock provided.
286
20 Nov 2011
PART 4: SECTION 5 PHYSICAL SECURITY PROTECTION OF BUILDINGS
Effective security relies on the appropriate combination of physical and electronic measures for the risks faced and the effective management of those facilities and maintenance of the security solutions and measures implemented. To prevent unauthorised entry into a building or area within a building, the components and materials used to construct that building/area must delay intruders sufficiently to allow an appropriate response. The effort an intruder needs to exert in order to gain entry is affected by a number of factors which, if countered by good physical security, will increase the likelihood of deterring potential intruders from even attempting entry. These factors include: Preparation and planning - The longer the criminal needs to take to survey a site and develop ways of overcoming the security measures without detection, the more likely they are to be deterred. Time spent attempting entry - The more the security delays the intruder when attempting entry, the greater the risk of them being caught and therefore the more likely they are to be deterred. Sourcing and transporting tools to overcome the physical security measures in place - The greater the number/weight of tools the intruder needs to use to overcome the security, and the more specialist the tools they need, the greater the risk of being caught and the more likely they are to be deterred. So how do specifiers determine whether physical security measures will be effective at deterring and delaying unauthorised entry? LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers classifies the resistance to forced entry provided by security products, systems and building materials. While previous versions of the standard specified six levels of resistance (security ratings), the latest versions (Issue 6 and 7) specify eight security ratings. The levels of risk on which the security ratings issued in issue 6 and 7 are based are represented in the following chart. HIGH RISK
LPS 1175 SR 8 LPS 1175 SR 7 LPS 1175 SR 6 LPS 1175 SR 5 LPS 1175 SR 4 LPS 1175 SR 3
LOW RISK
20 Nov 2011
Products certified to this standard provide 20 minutes of resistance to extrem e means of attempting forced entry into higher value storage areas. Products certified to these standards provide 10 minutes of resistance to professional means of attempting forced entry into higher value storage areas using a wide range of tools including mains powered tools. Products certified to these standards resist experienced attempts at forced entry using a wide range of tools including battery powered tools lasting up to 10 minutes (SR 4 and 5) or 5 minutes (SR 3).
LPS 1175 SR 2
Products certified to this standard provide 3 m inutes of resistance to determined attack by an opportunist burglar using a range of techniques including those that involve creation of noise.
LPS 1175 SR 1
Products certified to this standard provide 1 m inute of resistance to opportunist attem pts at entry using a range of techniques including those that create noise such as those involving breaking glass.
287
PART 4: SECTION 5 PHYSICAL SECURITY PROTECTION OF BUILDINGS LPS 1175 supports the assessment, approval and specification of security doors, shutters and grilles together with many other products and systems designed to prevent unauthorised access by mechanical means. These include:
Cladding Systems Fences and walls Fixed Grilles Folding Doorsets
Garage Doors Roofing Systems Temporary Buildings Sheds and Tool Stores
Sky Lights Strongpoints and Enclosures Vehicles Windows
LPS 1175 is based on manual attack testing with the resistance provided by the products measured in terms of the attack tools and time available to the attacker. It enables specifiers to select products according to the risk. Further information on the security rating system and attack tools can be found in the standard itself, which can be downloaded from the Red Book web site www.RedBookLive.com. In addition to certifying windows, doors and shutters to LPS 1175, LPCB also offers approval of these products to the following standards: PAS 23-1
General performance requirements for door assemblies - Part 1: Single leaf, external door assemblies to dwellings
PAS 24-1
Enhanced security performance requirements for door assemblies - Part 1: Single and double leaf, hinged external door assemblies to dwellings
BS 7950
Specification for enhanced security performance of windows for domestic applications
EN 1627
Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance Requirements and classification
PAS 23-1, PAS 24-1 and BS 7950 are aimed at domestic applications. Secured by Design report a significant reduction in domestic burglary where products approved to PAS 24-1 and BS 7950 have been used. The levels of resistance offered by products approved to PAS 24-1 and BS 7950 is generally lower than that provided by products approved to LPS 1175, especially if the products incorporate glass or in situations where the criminal can make sustained amounts of noise while attempting entry. EN 1627 is the European standard aimed at façade security products used in domestic and commercial situations. Specifiers should note that, although the working times specified for grades 2, 3 and 4 in EN 1627 match those defined for ratings 2, 3 and 4 in LPS 1175 (i.e. 3 minutes, 5 minutes and 10 minutes respectively), LPS 1175 permits a far wider array of tools and attack techniques to be used. Specifiers should therefore not assume products meeting EN 1627 will offer the ‘same’ levels of resistance when tested to LPS 1175. In fact, a number of products rated to grade 4 in ENV 1627 tested by BRE to LPS 1175 have failed to achieve above a Security Rating 2 classification. Furthermore, because anyone can test products to EN 1627 and the quality of testing can greatly impact on the ratings attributed to a product, this can affect the resistance to attack actually delivered by products rated to the standard. LPCB therefore only recognises those tests conducted to this standard by its own experienced test engineers or by other laboratories that have demonstrated they conduct the tests to suitably high standards. Hotel Doorsets In addition to these standards, LPCB has developed a standard for Hotel Doorsets. LPS 1268 Specification for the testing and classification of hotel bedroom doorsets covers many aspects of the doorset’s
288
20 Nov 2011
PART 4: SECTION 5 PHYSICAL SECURITY PROTECTION OF BUILDINGS performance, from security performance through to fire resistance, acoustic and general durability. Copies of the standard are available free of charge and can be obtained by emailing [email protected] Product Selection When selecting a security door, shutter, grille or other façade element, it is important to note aspects such as the size, locking systems, modes and directions of opening, and the type, size and location of any glazing incorporated within the product or system. All can affect the level of security provided by the product. These aspects of each certified product have therefore been described to enable selection of the most appropriate product for the desired application. Where options, such as glazed in-fills within door leaves, are not covered in the listing, those options fall outside the scope of that product’s approval. Unless otherwise stated, the security ratings attributed to the products listed require all lock bolts to be fully engaged and any deadlocking mechanism provided must be engaged. If a product is shown to achieve more than one security rating: The lower rating indicates the security rating achieved by the product when in the “minimum locked condition”, that is, when the opening element (e.g. door leaf) is closed and only automatic latching mechanisms are engaged. The higher rating indicates the security rating achieved by the product when any additional manually operated deadlocks fitted to the opening element are engaged. It is important to ensure that the products are installed in accordance with the manufacturer’s instructions and that all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly checked to ensure that they are in good condition and that they have not been tampered with. For added peace of mind, we recommend products are installed by companies certified to LPS 1271 Requirements for the LPCB Approval and Listing of companies installing fire and security doorsets and shutters, and smoke barriers for a scope covering the product being specified. A list of currently approved installers is provided in Volume 2.
20 Nov 2011
289
PART 4: SECTION 5.1 HIGH SECURITY DOORSETS
Doorsets listed in this section are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and freestanding barriers. Section 5.1.1 lists high security plain leaf hinged doorsets Section 5.1.2 lists high security glazed hinged doorsets Section 5.1.3 lists high security hinged doorsets with other leaf designs, such as those incorporating mesh or fixed bars. Section 5.1.4 lists high security folding doorsets For details of hinged doorsets approved to PAS 23-1 and PAS 24-1 please refer to sections 5.2.1 and 5.2.2 respectively.
290
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
AccentHansen Greengate Industrial Park, Greengate, Middleton, Manchester M24 1SW, United Kingdom Tel: +44 (0)161 284 4100 • Fax: +44 (0)161 655 3119 E-mail: [email protected] • Website: www.servicehansen.com Certificate No: 021c to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
Frame Dimensions Height (m)
Frame Dimensions Width (m)
Secureshield 4
Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset Double leaf, outward opening hinged security Single leaf, outward opening hinged security doorset
2.090
Compatible Locking Systems on Passive Leaf N/A
Locked Condition
Security Rating
Cert. No.
1.275
Compatible Locking Systems on Active Leaf 3
Minimum
3
021c/01
2.090
1.775
3
4, 5 or 6
Minimum
3
2.090
1.775
1, 2 or 3
4, 5 or 6
Optimum
4
2.090
1.275
1, 2 or 3
N/A
Optimum
4
Compatible Locking Systems
20 Nov 2011
291
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Com patible Locking System
Locking System
1
Assa Mico 942-3 MSD1
2
3
4 5
6
Locked Com patible operating devices Condition External Face Internal Face
Type
Three point panic exit device fitted w ith MSD deadlocking device Three point Assa Mico 942-3P MSD1 emergency exit device operated by a push pad and fitted w ith the MSD deadlocking device Three point Assa Mico 942-3L MSD1 emergency exit device operated by a lever handle and fitted w ith the MSD deadlocking device Assa Mico 942 Tw o point panic exit device Assa Mico 942P Tw o point emergency exit device operated by a push pad Assa Mico 942L Tw o point emergency exit device operated by a lever handle
Optimum2
None
Key and panic bar
Optimum2
None
Key and push pad
Optimum2
None
Key and lever handle
Minimum
Lever handle
None
Panic bar
None
Push pad
None
Lever handle
Notes: 1. The MSD (Micro Switched Deadlock) system is operated by key from inside. This must be deadlocked in order to achieve the level of security relating to the optimum locked condition. 2. Although outside the scope of LPS1175: Issue 5, special consideration should be paid to the deadlocking of the Assa Mico panic and emergency three point locking system. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or emergency device, since doing so can inhibit means of escape. For further information, reference should be made to the appropriate standards for emergency exit and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively. Certificate No: 021d to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Doorset Configuration
SecureShield 2
Single leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset
292
Minimum Structural Opening Height (m) 1.5
Maximum Structural Opening Height (m) Refer to compatible locking systems
Minimum Structural Opening Width (m) 0.5
Maximum Structural Opening Width (m) 1.25
Locking System Active Leaf
Locking Sysetm Passive Leaf
Security Rating
Cert. No.
1
-
2
021d/01
1.5
Refer to compatible locking systems
0.5
1.25
2
-
2
1.5
Refer to compatible locking systems
0.5
1.25
3
-
2
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Product Name
Doorset Configuration
Single leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset
Minimum Structural Opening Height (m) 1.5
Maximum Structural Opening Height (m) Refer to compatible locking systems
Minimum Structural Opening Width (m) 0.5
Maximum Structural Opening Width (m) 1.25
Locking System Active Leaf
Locking Sysetm Passive Leaf
Security Rating
6
-
2
1.5
Refer to compatible locking systems
1.3
2.5
1
4
2
1.5
Refer to compatible locking systems
1.3
2.5
2
4
2
1.5
Refer to compatible locking systems
1.3
2.5
5
5
2
1.5
Refer to compatible locking systems
1.3
2.5
7
7
2
Cert. No.
021d/02
Compatible Locking Systems
Com patible Locking System
Manufacturer
Model
Description
1
Associated Finishers Limited
QFSL
2
Associated Finishers Limited
3
Com patible Cylinders
Sashlock
Maxim um Structural Opening Height (m) 2.4
QFDL
Deadlock
2.4
A
Fred Duncombe Limited
Exidor 702B/30S w ith 710EC
Tw o point panic bar locking system w ith external access device
2.45
B
4
Fred Duncombe Limited
Exidor HS923
Tow er bolts
2.4
-
5
Fred Duncombe Limited
Exidor 701BD/30S w ith 710EC
Double door panic bar locking system (single point anti-thrust panic exit locking system w ith external access device on active leaf and a tw o point panic exit locking system on passive leaf)
2.4
B
6
Fred Duncombe Limited Fred Duncombe Limited
Exidor 702B/30S Exidor 701BD/30S
Tw o point panic bar locking system w ith no external entry Double door panic bar locking system w ith no external entry (single point anti-thrust panic exit locking system and a tw o point panic exit locking system on passive leaf)
2.45
-
2.4
-
7
A
Compatible Cylinders
20 Nov 2011
293
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Cylinder Manufacturer Reference A Assa B
Zone
Model
Type
R527
Double europrofile cylinder (key:thumbturn)
1500
Single europrofile cylinder
Ascot Doors Limited Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800 E-mail: [email protected] • Website: www.ascotdoors.co.uk Certificate No: 131d to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Doorset Configuration
Centurion A355
Single leaf, outward opening hinged doorset Single leaf, outward opening hinged doorset Double leaf, outward opening hinged doorset Single leaf, outward opening hinged doorset Double leaf, outward opening hinged doorset
Centurion A364S
Centurion A364D
Centurion A363S
Centurion A363D
Minimum Clear Opening Height (m) 1.8
Minimum Clear Opening Width (m) 0.7
Maximum Clear Opening Height (m) 2.5
Maximum Clear Opening Width (m) 1.35
Security Rating1
Cert. No.
4
131d/01
1.8
0.7
2.9
1.35
4
131d/02
1.8
1.4
2.9
2.61
4
131d/03
1.8
0.7
2.9
1.35
3
131d/04
1.8
1.4
2.9
2.61
3
131d/05
Compatible Locking Configurations
294
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Product Name
Doorset Configuration
Compatible Locking System s Active Leaf
Passive Leaf
Centurion A355S Single leaf, outw ard opening hinged security doorset2
19
N/A
Centurion A363S Single leaf, outw ard opening hinged security doorset2
4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34 and 35
N/A
Centurion A363D Double leaf, outw ard opening hinged security doorset2,3
4, 5, 6, 7, 8, 9, 10 ,11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34 and 35
1, 2, 3
Centurion A364S Single leaf, outw ard opening hinged security doorset2
5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25, 27, 29, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53 and 54
N/A
Centurion A364D Double leaf, outw ard opening hinged security doorset2,3
5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25, 27, 29, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53 and 54
1, 2, 3
Compatible Locking Systems
Com patible Locking System s
Manufacturer
1
Tindall Engineering Ltd
Mico 942
2-w ay panic exit device
None
Panic bar
-
2
Tindall Engineering Ltd
Mico 942P
2-w ay emergency exit device
None
Push pad
-
3
Tindall Engineering Ltd
Mico 942L
2-w ay emergency exit device
None
Lever handle
-
4
Tindall Engineering Ltd
Mico 942-3 / ELK 3-w ay panic exit 3 device
Key (via ELK3)
Panic bar
A
5
Tindall Engineering Ltd
Mico 942-3
None
Panic bar
-
Model
Type
Com patible Operating Devices External Face
20 Nov 2011
3-w ay panic exit device
Compatible Cylinders 4
Internal Face
295
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
296
6
Tindall Engineering Ltd
Mico 942-3P / ELK 3
3-w ay emergency exit device
Key (via ELK3)
Push pad
A
7
Tindall Engineering Ltd
Mico 942-3P
3-w ay emergency exit device
None
Push pad
-
8
Tindall Engineering Ltd
Mico 942-3L / ELK 3
3-w ay emergency exit device
Key (via ELK3)
Lever handle
A
9
Tindall Engineering Ltd
Mico 942-3L
3-w ay emergency exit device
None
Lever handle
-
10
Tindall Engineering Ltd
Mico 942-3 EM SEC / HSCH 3
3-w ay locking system w ith solenoid deadlock and electromechanical access control pow ered by 12 V 5
External access control device6 or key override w ith HSCH3 cylinder guard and lever handle
Internal access control device or thumbturn override and ‘full w idth’ push plate
B
11
Tindall Engineering Ltd
Mico 942-3 EM SEC
3-w ay locking External access system w ith solenoid control device6 deadlock and electro- and lever handle mechanical access control pow ered by 12 V 5
Internal access control device or thumbturn override and ‘full w idth’ push plate
-
12
Tindall Engineering Ltd
Mico 942-3P EM 3-w ay locking system w ith solenoid SEC / HSCH 3 deadlock and electromechanical access control pow ered by 12 V 5
Internal access control device or thumbturn override and push pad
B
13
Tindall Engineering Ltd
Mico 942-3P EM 3-w ay locking External access SEC system w ith solenoid control device6 deadlock and electro- and lever handle mechanical access control pow ered by 12 V 5
Internal access control device or thumbturn override and push pad
-
14
Tindall Engineering Ltd
Mico 942-3L EM 3-w ay locking system w ith solenoid SEC / HSCH 3 deadlock and electromechanical access control pow ered by 12 V 5
Internal access control device or thumbturn override and lever handle
B
15
Tindall Engineering Ltd
Mico 942-3L EM 3-w ay locking External access SEC system w ith solenoid control device6 deadlock and electro- and lever handle mechanical access control pow ered by 12 V 5
Internal access control device or thumbturn override and lever handle
-
External access control device6 or key override w ith HSCH3 cylinder guard and lever handle
External access control device6 or key override w ith HSCH3 cylinder guard and lever handle
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 16
Tindall Engineering Ltd
Mico 942-3L INT 3-w ay locking AD / HSCH 3 system w ith automatic deadlock
HSCH3 cylinder guard and lever handle
Thumbturn and lever handle
B
17
Tindall Engineering Ltd
Mico 942-3L INT 3-w ay locking AD system w ith automatic deadlock
None
Thumb turn and lever handle
-
18
Tindall Engineering Ltd
Mico 942-3 INT MD / HSCH 3
3-w ay locking system w ith manual deadlock
HSCH3 cylinder guard and lever handle
Key or thumbturn and full w idth push plate
B
19
Tindall Engineering Ltd
Mico 942-3 INT MD
3-w ay locking system w ith manual deadlock
None
Key or thumbturn and full w idth push plate
-
20
Tindall Engineering Ltd
Mico 942-3P INT 3-w ay locking MD / HSCH 3 system w ith manual deadlock
HSCH3 cylinder guard and lever handle
Key or thumbturn and push pad
B
21
Tindall Engineering Ltd
Mico 942-3P INT 3-w ay locking MD system w ith manual deadlock
None
Key or thumbturn and push pad
-
22
Tindall Engineering Ltd
Mico 942-3L INT 3-w ay locking MD / HSCH 3 system w ith manual deadlock
HSCH3 cylinder guard and lever handle
Key or thumbturn and lever handle
B
23
Tindall Engineering Ltd
Mico 942-3L INT 3-w ay locking MD system w ith manual deadlock
None
Key or thumbturn and lever handle
-
24
Tindall Engineering Ltd
Mico 942-3 SATE EM SEC / HSCH 3
External access Panic bar control device6 or key override w ith HSCH3 cylinder guard and lever handle
25
Tindall Engineering Ltd
Mico 942-3 SATE 3-w ay panic exit External access EM SEC device w ith solenoid control device6 deadlock and electro and lever handle mechanical access control pow ered by 12 V 5
20 Nov 2011
3-w ay panic exit device w ith solenoid deadlock and electro mechanical access control pow ered by 12 V 5
Panic bar
B
-
297
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
298
26
Tindall Engineering Ltd
Mico 942-3P SATE EM SEC / HSCH 3
3-w ay emergency exit device w ith solenoid deadlock and electro mechanical access control pow ered by 12 V 5
External access Push pad control device6 or key override w ith HSCH3 cylinder guard and lever handle
B
27
Tindall Engineering Ltd
Mico 942-3P SATE EM SEC
3-w ay emergency exit device w ith solenoid deadlock and electro mechanical access control pow ered by 12 V 5
External access control device6 and lever handle
-
28
Tindall Engineering Ltd
Mico 942-3L SATE EM SEC / HSCH 3
3-w ay emergency exit device w ith solenoid deadlock and electro mechanical access control pow ered by 12 V 5
External access Lever handle control device6 or key override w ith HSCH3 cylinder guard and lever handle
B
29
Tindall Engineering Ltd
Mico 942-3L SATE EM SEC
3-w ay emergency exit device w ith solenoid deadlock and electro mechanical access control pow ered by 12 V 5
External access control device6 and lever handle
Lever handle
-
30
Tindall Engineering Ltd
Mico 942-3 SATE 3-w ay panic exit AD / HSCH 3 device w ith automatic deadlock
Key via HSCH3 cylinder guard and lever handle
Panic bar
B
31
Tindall Engineering Ltd
Mico 942-3P 3-w ay emergency SATE AD / HSCH exit device w ith 3 automatic deadlock
Key via HSCH3 cylinder guard and lever handle
Push pad
B
32
Tindall Engineering Ltd
3-w ay emergency Mico 942-3L SATE AD / HSCH exit device w ith 3 automatic deadlock
Key via HSCH3 cylinder guard and lever handle
Lever handle
B
33
Tindall Engineering Ltd
Mico 942-3 SATE 3-w ay panic exit MD / HSCH 3 device w ith manual deadlock
Key via HSCH3 cylinder guard and lever handle
Panic bar
B
34
Tindall Engineering Ltd
Mico 942-3P 3-w ay emergency SATE MD / HSCH exit device w ith 3 manual deadlock
Key via HSCH3 cylinder guard and lever handle
Push pad
B
35
Tindall Engineering Ltd
3-w ay emergency Mico 942-3L SATE MD / HSCH exit device w ith 3 manual deadlock
Key via HSCH3 cylinder guard and lever handle
Lever handle
B
Push pad
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 36
Tindall Engineering Ltd
Mico 942-3 / ELK 3-w ay panic exit 4 device
Key (via ELK4)
Panic bar
A
37
Tindall Engineering Ltd
Mico 942-3P / ELK 4
3-w ay emergency exit device
Key (via ELK4)
Push pad
A
38
Tindall Engineering Ltd
Mico 942-3L / ELK 4
3-w ay emergency exit device
Key (via ELK4)
Lever handle
A
39
Tindall Engineering Ltd
Mico 942-3 EM SEC / HSCH 4
3-w ay locking system w ith solenoid deadlock and electromechanical access control pow ered by 12 V 5
External access control device6 or key override w ith HSCH4 cylinder guard and lever handle
Internal access control device or thumbturn override and ‘full w idth’ push plate
B
40
Tindall Engineering Ltd
Mico 942-3P EM 3-w ay locking SEC / HSCH 4 system w ith solenoid deadlock and electromechanical access control pow ered by 12 V 5
External access control device6 or key override w ith HSCH4 cylinder guard and lever handle
Internal access control device or thumbturn override and push pad
B
41
Tindall Engineering Ltd
Mico 942-3L EM 3-w ay locking SEC / HSCH 4 system w ith solenoid deadlock and electromechanical access control pow ered by 12 V 5
External access control device6 or key override w ith HSCH4 cylinder guard and lever handle
Internal access control device or thumbturn override and lever handle
B
42
Tindall Engineering Ltd
Mico 942-3L INT 3-w ay locking AD / HSCH 4 system w ith automatic deadlock
HSCH4 cylinder guard and lever handle
Thumbturn and lever handle
B
43
Tindall Engineering Ltd
Mico 942-3 INT MD / HSCH 4
3-w ay locking system w ith manual deadlock
HSCH4 cylinder guard and lever handle
Key or thumbturn and full w idth push plate
B
44
Tindall Engineering Ltd
Mico 942-3P INT 3-w ay locking MD / HSCH 4 system w ith manual deadlock
HSCH4 cylinder guard and lever handle
Key or thumbturn and push pad
B
45
Tindall Engineering Ltd
Mico 942-3L INT 3-w ay locking MD / HSCH 4 system w ith manual deadlock
HSCH4 cylinder guard and lever handle
Key or thumbturn and lever handle
B
20 Nov 2011
299
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 46
Tindall Engineering Ltd
Mico 942-3 SATE EM SEC / HSCH 4
3-w ay panic exit device w ith solenoid deadlock and electro mechanical access control pow ered by 12 V 5
External access Panic bar control device6 or key override w ith HSCH4 cylinder guard and lever handle
B
47
Tindall Engineering Ltd
Mico 942-3P SATE EM SEC / HSCH 4
3-w ay emergency exit device w ith solenoid deadlock and electro mechanical access control pow ered by 12 V 5
External access Push pad control device6 or key override w ith HSCH4 cylinder guard and lever handle
B
48
Tindall Engineering Ltd
Mico 942-3L SATE EM SEC / HSCH 4
3-w ay emergency exit device w ith solenoid deadlock and electro mechanical access control pow ered by 12 V 5
External access Lever handle control device6 or key override w ith HSCH4 cylinder guard and lever handle
B
49
Tindall Engineering Ltd
Mico 942-3 SATE 3-w ay panic exit AD / HSCH 4 device w ith automatic deadlock
Key via HSCH4 cylinder guard and lever handle
Panic bar
B
50
Tindall Engineering Ltd
3-w ay emergency Mico 942-3P SATE AD / HSCH exit device w ith 4 automatic deadlock
Key via HSCH4 cylinder guard and lever handle
Push pad
B
51
Tindall Engineering Ltd
Mico 942-3L 3-w ay emergency SATE AD / HSCH exit device w ith 4 automatic deadlock
Key via HSCH4 cylinder guard and lever handle
Lever handle
B
52
Tindall Engineering Ltd
Mico 942-3 SATE 3-w ay panic exit MD / HSCH 4 device w ith manual deadlock
Key via HSCH4 cylinder guard and lever handle
Panic bar
B
53
Tindall Engineering Ltd
3-w ay emergency Mico 942-3P SATE MD / HSCH exit device w ith 4 manual deadlock
Key via HSCH4 cylinder guard and lever handle
Push pad
B
54
Tindall Engineering Ltd
3-w ay emergency Mico 942-3L SATE MD / HSCH exit device w ith 4 manual deadlock
Key via HSCH4 cylinder guard and lever handle
Lever handle
B
Compatible Cylinders
Cylinder Reference A B
Manufacturer
Model
Type
Assa
4801
Half oval mechanical cylinder
Assa
4807
Half oval mechanical cylinder
Notes: 1. These ratings apply to doorsets with locking fully engaged, i.e. in optimum locked condition. The doorsets achieve Security Rating 2 when the following locking systems are fitted and left in the minimum locked condition, e.g. internal manual deadlock not engaged: 18, 19, 20, 21, 22, 23, 43, 44 and 45. 2. Although outside the scope of LPS 1175: Issue 6, special consideration should be paid to the use of locking systems with separate deadlocks, e.g. Mico 942-3 INT MD. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a
300
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
3.
4. 5. 6.
panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or emergency device. For further information, please refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively. Although outside the scope of LPS 1175: Issue 6, special consideration should be paid to the use of single operating panic or emergency exit devices. This is because it is generally accepted that when two panic or emergency exit devices are fitted to double doorsets the operation of either device should disengage simultaneously such that both leafs can open. For further information, please refer to the appropriate standard for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively. This is applicable to the external cylinders only. Due to the resistance afforded by the doorset there is no restrictions on the type of internal cylinder used. Fail secure version only. The resistance of the access control locks to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that Ascot Doors Limited satisfy themselves that the components are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage.
Bradbury Security Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888 E-mail: [email protected] • Website: www.bradburyuk.com Certificate No: 312c to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
Fortress 2
Single leaf outward opening security louvered door
Minimum Height (m) 1.5
Minimum Width (m) 0.5
Maximum Height (m) 2.3
Maximum Width (m) 1.0
Security Rating
Cert. No.
2
312c/01
Compatible Locking Devices
Lock
Type
Siver 921
Three-point locking system
Approved product (LPCB Ref. No. 312c/01)
Certificate No: 312d to LPS 1175: Issue 6
Hinged Doorsets Product Name
Type
M2M 1
Single leaf outward opening hinged security doorset
Minimum Clear Opening Height (m) 1745
Maximum Clear Opening Height (m) 2475
Minimum Clear Opening Width (m) 740
Maximum Clear Opening Width (m) 1210
Compataible Locking Systems
Security Rating
Cert. No.
1, 2, 4 and 5
1
312d/01
1745
2410
740
990
3
1
Compataible Locking Systems
20 Nov 2011
301
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Option
Manufacturer
Type
Operating Devices External Face
Compatible Cylinders
Internal face
1
Union
JL2C21R sash Key and lever lock handle
Key and lever handle
Baton double europrofile cylinder (key:key)
2
Union
JL2C22R dead Key and fixed lock pull handle
Key and fixed pull handle
Baton double europrofile cylinder (key:key)
3
Yale
Yale 82 deadbolt
Turn handle
Yale 82 rim cylinder
4
IDC
IDC 736 2 point None panic exit system
Panic bar
None
5
Hooply
Combat Key and lever multipoint handle locking system
Thumbturn and lever handle
Combat 65 mm europrofile double cylinder (key:thumbturn)
Key and fixed pull handle
Certificate No: 312e to LPS 1175: Issue 7
Hinged Security Doorsets Product Name
Product Type
M2M3
Single leaf outward opening doorset Double leaf outward opening doorset4
Minimum Structural Opening Height (m) 1.745
Maximum Structural Opening Height (m) 2.43
Minimum Structural Opening Width (m) 0.74
Maximum Structural Opening Width (m) 1.18
Security Rating
Cert. No.
31, 2, 3
312e/01
1.745
2.43
1.15
2.20
31, 2, 3
Approved Locking Configurations
LPCB Ref. No.
Product Name
Type
Compatible Locking Devices
312e/01
M2M3
Single leaf outw ard opening plain leafed doorset
5
Single leaf outw ard opening louvred doorset Double leaf outw ard opening plain leafed doorset5, 6, 7 Double leaf outw ard opening louvred doorset
Active Leaf
Passive Leaf
1, 3 to 182
N/A
2
N/A
1, 3 to 182
62, 64, 66, 76, 78, 103, 105, 107, 109, 183 or 184 183 or 184
2
Compatible Locking Devices8
302
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Com patible Manufacturer Model Locking System 1 Hooply Combat 2 3
4
5
6
7
8
9
Bradbury Security Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited
Abryll PE2 /ELK3
Type
Com patible Operating Device External Face
Multi-point locking system 4-w ay locking mechanism Single point panic exit device
Internal Face
Key and lever handle Key and lever handle Key and lever handle
Com patible Cylinders
Key and lever handle
Latch mechanism and lever handle Panic bar
None
Panic bar
AB AW, AX, AY and AZ A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q and R -
Abryll PE2
Single point panic exit device
Abryll PE1 /ELK3
A, B, C, D, E, F, G, Single point Key and lever handle Push pad H, I, J, K, L, M, N, emergency exit O, P, Q and R device Single point None Push pad emergency exit device A, B, C, D, E, F, G, Single point Key and lever handle Lever handle H, I, J, K, L, M, N, emergency exit O, P, Q and R device Single point None Lever handle emergency exit device Electro-mechanical Electro-mechanical A, B, C, D, E, F, G, Single point locking system w ith solenoid H, I, J, K, L, M, N, access control access control O, P, Q, R, AW, deadlocking and 12v device10 w ith key device w ith thumb AX, AY, AZ, BA, electro-mechanical override and lever turn override and BB and BC access control 9 handle push plate
Abryll PE1
Abryll PE3 /ELK3 Abryll PE3
Abryll EM2 /USCH3
10
Tindall Engineering Limited
Abryll EM2
Electro-mechanical Single point locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push plate
11
Tindall Engineering Limited
Abryll EM1 /USCH3
Electro-mechanical Single point locking access control system w ith solenoid deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical A, B, C, D, E, F, G, access control H, I, J, K, L, M, N, device w ith thumb O, P, Q, R, AW, turn override and AX, AY, AZ, BA, push pad BB and BC
12
Tindall Engineering Limited
Abryll EM1
Electro-mechanical Single point locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push pad
20 Nov 2011
-
-
303
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 13
Tindall Engineering Limited
Abryll EM3 /USCH3
Single point locking Electro-mechanical system w ith solenoid access control deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical A, B, C, D, E, F, G, access control H, I, J, K, L, M, N, device w ith thumb O, P, Q, R, AW, turn override and AX, AY, AZ, BA, lever handle BB and BC
14
Tindall Engineering Limited
Abryll EM3
Electro-mechanical Single point locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and lever handle
-
15
Tindall Engineering Limited
Abryll AD3 /USCH3
Single point locking system w ith automatic deadlocking
Key and lever handle
Key or thumbturn and lever handle
16
Tindall Engineering Limited
Abryll AD3
Key or thumbturn and lever handle
17
Tindall Engineering Limited
Abryll MD2 /USCH3
Single point locking None system w ith automatic deadlocking Single point locking Key and lever handle system w ith manual deadlocking
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
18
Tindall Engineering Limited Tindall Engineering Limited
Abryll MD2
Tindall Engineering Limited Tindall Engineering Limited
Abryll MD1
19
20
21
22
23
24
304
Abryll MD1 /USCH3
Abryll MD3 /USCH3
Tindall Engineering Limited Tindall Engineering Limited
Abryll MD3
Tindall Engineering Limited
Abryll SATE EM2
Abryll SATE EM2 /USCH3
Key or thumb turn and push plate
Single point locking None system w ith manual deadlocking Single point locking Key and lever handle system w ith manual deadlocking
Key or thumb turn and push plate
Single point locking None system w ith manual deadlocking Single point locking Key and lever handle system w ith manual deadlocking
Key or thumb turn and push pad
Single point locking system w ith manual deadlocking Single point panic exit device w ith solenoid deadlocking and 12v electromechanical access control9 Single point panic exit device w ith solenoid deadlocking and 12v electromechanical access control9
Key or thumb turn and push pad
Key or thumb turn and lever handle
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
None
Key or thumb turn and lever handle
Electro-mechanical access control device10 w ith key override and lever handle
Panic bar
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
Electro-mechanical access control device10 and lever handle
Panic bar
-
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 25
Tindall Engineering Limited
Abryll SATE EM1 /USCH3
26
Tindall Engineering Limited
Abryll SATE EM1
27
Tindall Engineering Limited
Abryll SATE EM3 /USCH3
28
Tindall Engineering Limited
Abryll SATE EM3
29
Tindall Engineering Limited
Abryll SATE AD2/USCH3
30
Tindall Engineering Limited
Abryll SATE AD1/USCH3
31
Tindall Engineering Limited
Abryll SATE AD3/USCH3
32
Tindall Engineering Limited
Abryll SATE MD2/USCH3
33
Tindall Engineering Limited
Abryll SATE MD1/USCH3
Single point emergency exit device w ith manual deadlocking
Key and lever handle
Push pad
34
Tindall Engineering Limited
Abryll SATE MD3/USCH3
Single point emergency exit device w ith manual deadlocking
Key and lever handle
Lever handle
20 Nov 2011
Electro-mechanical Single point access control emergency exit device10 w ith key device w ith solenoid deadlocking and 12v override and lever handle electro-mechanical access control9 Single point Electro-mechanical emergency exit access control device w ith solenoid device10 and lever deadlocking and 12v handle electro-mechanical access control9 Electro-mechanical Single point access control emergency exit device10 w ith key device w ith solenoid deadlocking and 12v override and lever handle electro-mechanical access control9 Electro-mechanical Single point access control emergency exit device w ith solenoid device10 and lever handle deadlocking and 12v electro-mechanical access control9 Single point panic Key and lever handle exit device w ith automatic deadlocking Single point Key and lever handle emergency exit device w ith automatic deadlocking Single point Key and lever handle emergency exit device w ith automatic deadlocking Single point panic Key and lever handle exit device w ith manual deadlocking
Push pad
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
Push pad
-
Lever handle
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
Lever handle
-
Panic bar
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
Push pad
Lever handle
Panic bar
305
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 35
Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited
Abryll PE2 / EURO ELK 3 Abryll PE1/EURO ELK3 Abryll PE3/EURO ELK3 Abryll EPC EM2/USCH3
39
Tindall Engineering Limited
Abryll EPC EM2
Electro-mechanical Single point locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push plate
-
40
Tindall Engineering Limited
Abryll EPC EM1/USCH3
Electro-mechanical Single point locking system w ith solenoid access control deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical access control device w ith thumb turn override and push pad
AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
41
Tindall Engineering Limited
Abryll EPC EM1
Electro-mechanical Single point locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push pad
-
42
Tindall Engineering Limited
Abryll EPC EM3/USCH3
Electro-mechanical Single point locking system w ith solenoid access control deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical access control device w ith thumb turn override and lever handle
AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
43
Tindall Engineering Limited
Abryll EPC EM3
Electro-mechanical Single point locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and lever handle
-
44
Tindall Engineering Limited
Abryll EPC AD3 /USCH 3
Single point locking system w ith automatic deadlocking
Key and lever handle
Key or thumb turn and lever handle
45
Tindall Engineering Limited
Abryll EPC AD3
Single point locking system w ith automatic deadlocking
None
Key or thumb turn and lever handle
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
36
37
38
306
Single point panic exit device
Key and lever handle
Panic bar
Single point Key and lever handle Push pad emergency exit device Single point Key and lever handle Lever handle emergency exit device Electro-mechanical Electro-mechanical Single point locking system w ith solenoid access control access control deadlocking and 12v device10 w ith key device w ith thumb electro-mechanical override and lever turn override and access control9 handle push plate
S, T, U, V, W, X Y, Z and AA S, T, U, V, W, X Y, Z and AA S, T, U, V, W, X Y, Z and AA AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 46
Tindall Engineering Limited
Abryll EPC MD2/USCH3
Single point locking Key and lever handle system w ith manual deadlocking
Key or thumb turn and push plate
47
Tindall Engineering Limited Tindall Engineering Limited
Abryll EPC MD2
Single point locking None system w ith manual deadlocking Single point locking Key and lever handle system w ith manual deadlocking
Key or thumb turn and push plate
Tindall Engineering Limited Tindall Engineering Limited
Abryll EPC MD1
Single point locking None system w ith manual deadlocking Single point locking Key and lever handle system w ith manual deadlocking
Key or thumb turn and push pad
Tindall Engineering Limited Tindall Engineering Limited
Abryll EPC MD3
Key or thumb turn and lever handle
53
Tindall Engineering Limited
Abryll EPC SATE EM1/USCH3
54
Tindall Engineering Limited
Abryll EPC SATE EM3/USCH3
55
Tindall Engineering Limited
Abryll EPC SATE AD2/USCH3
56
Tindall Engineering Limited
Abryll EPC SATE AD1/USCH3
57
Tindall Engineering Limited
Abryll EPC SATE AD3/USCH3
Single point locking None system w ith manual deadlocking Electro-mechanical Single point panic access control exit device w ith solenoid deadlocking device10 w ith key override and lever and 12v electrohandle mechanical access control9 Electro-mechanical Single point access control emergency exit device10 w ith key device w ith solenoid deadlocking and 12v override and lever handle electro-mechanical access control9 Electro-mechanical Single point access control emergency exit device10 w ith key device w ith solenoid deadlocking and 12v override and lever handle electro-mechanical access control9 Single point panic Key and lever handle exit device w ith automatic deadlocking Single point Key and lever handle emergency exit device w ith automatic deadlocking Single point Key and lever handle emergency exit device w ith automatic deadlocking
48
49
50
51
52
20 Nov 2011
Abryll EPC MD1/USCH3
Abryll EPC MD3/USCH3
Abryll EPC SATE EM2/USCH3
Key or thumb turn and push pad
Key or thumb turn and lever handle
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
Panic bar
S, T, U, V, W, X, Y, Z and AA
Push pad
S, T, U, V, W, X, Y, Z and AA
Lever handle
S, T, U, V, W, X, Y, Z and AA
Panic bar
S, T, U, V, W, X, Y, Z and AA
Push pad
S, T, U, V, W, X, Y, Z and AA
Lever handle
S, T, U, V, W, X, Y, Z and AA
307
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 58
59
60
Tindall Engineering Limited
61
Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited
62
63
64
65
66
67
308
Tindall Engineering Limited Tindall Engineering Limited
Abryll EPC SATE MD2/USCH3 Abryll EPC SATE MD1/USCH3
Single point panic exit device w ith manual deadlocking Single point emergency exit device w ith manual deadlocking Abryll EPC Single point SATE emergency exit MD3/USCH3 device w ith manual deadlocking Mico 942 /ELK 2-w ay panic exit 3 device
Key and lever handle
Panic bar
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Push pad
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Lever handle
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Panic bar
None
Panic bar
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q and R -
Mico 942
2-w ay panic exit device
Mico 942P /ELK 3
2-w ay emergency exit device
Key (via ELK 3) and lever handle
Push pad
Mico 942P
2-w ay emergency exit device
None
Push pad
Mico 942L /ELK 3
2-w ay emergency exit device
Key (via ELK 3) and lever handle
Lever handle
Mico 942L
2-w ay emergency exit device
None
Lever handle
Mico 942 EM SEC /USCH 3
Electro-mechanical 2- w ay locking system w ith solenoid access control deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical A, B, C, D, E, F, G, H, I, J, K, L, M, N, access control O, P, Q, R, AW, device w ith thumb AX, AY, AZ, BA, turn override and BB and BC push plate
Electro-mechanical 2- w ay locking access control system w ith solenoid deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push plate
68
Tindall Engineering Limited
Mico 942 EM SEC
69
Tindall Engineering Limited
Electro-mechanical Mico 942P EM 2- w ay locking access control SEC /USCH 3 system w ith solenoid deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q and R -
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q and R -
-
Electro-mechanical A, B, C, D, E, F, access control G, H, I, J, K, L, M, device w ith thumb N, O, P, Q, R, AW, turn override and AX, AY, AZ, BA, push pad BB and BC
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 70
Tindall Engineering Limited
Electro-mechanical Mico 942P EM 2- w ay locking system w ith solenoid access control SEC deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push pad
71
Tindall Engineering Limited
Electro-mechanical Mico 942L EM 2- w ay locking access control SEC /USCH 3 system w ith solenoid deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical A, B, C, D, E, F, G, H, I, J, K, L, M, N, access control O, P, Q, R, AW, device w ith thumb AX, AY, AZ, BA, turn override and BB and BC lever handle
72
Tindall Engineering Limited
Electro-mechanical Mico 942L EM 2- w ay locking access control system w ith solenoid SEC deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and lever handle
73
Tindall Engineering Limited
Mico 942L INT 2-w ay locking AD /USCH 3 system w ith automatic deadlocking
74
Tindall Engineering Limited
75
Tindall Engineering Limited
Mico 942L INT 2-w ay locking AD system w ith automatic deadlocking Mico 942 INT 2-w ay locking Key and lever handle MD /USCH 3 system w ith manual deadlocking
76
Tindall Engineering Limited Tindall Engineering Limited
2-w ay locking None system w ith manual deadlocking Mico 942P INT 2-w ay locking Key and lever handle MD /USCH 3 system w ith manual deadlocking
Tindall Engineering Limited Tindall Engineering Limited
Mico 942P INT 2-w ay locking MD system w ith manual deadlocking Mico 942L INT 2-w ay locking MD /USCH 3 system w ith manual deadlocking
Tindall Engineering Limited Tindall Engineering Limited
Mico 942L INT 2-w ay locking MD system w ith manual deadlocking Mico 942 2- w ay panic exit SATE EM SEC device w ith solenoid /USCH 3 deadlocking and 12v electro-mechanical access control9
77
78
79
80
81
20 Nov 2011
-
-
Key and lever handle Thumb turn and lever A, B, C, D, E, F, G, handle H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC Thumb turn and lever None handle
Mico 942 INT MD
Key or thumb turn and push plate
Key or thumb turn and push plate Key or thumb turn and push pad
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
None
Key or thumb turn and push pad
Key (via USCH 3) and lever handle
Key or thumb turn and lever handle
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
None
Key or thumb turn and lever handle
-
Electro-mechanical access control device10 w ith key override and lever handle
Push plate
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
309
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
310
82
Tindall Engineering Limited
Electro-mechanical Mico 942 2- w ay panic exit access control SATE EM SEC device w ith solenoid deadlocking and 12v device10 and lever handle electro-mechanical access control9 Electro-mechanical Mico 942P 2- w ay emergency access control SATE EM SEC exit device w ith /USCH 3 solenoid deadlocking device10 w ith key override and lever and 12v electrohandle mechanical access control9 Mico 942P 2- w ay emergency Electro-mechanical SATE EM SEC exit device w ith access control solenoid deadlocking device10 and lever and 12v electrohandle mechanical access control9 Electro-mechanical 2- w ay emergency Mico 942L SATE EM SEC exit device w ith access control /USCH 3 solenoid deadlocking device10 w ith key override and lever and 12v electrohandle mechanical access control9 Mico 942L 2- w ay emergency Electro-mechanical SATE EM SEC exit device w ith access control solenoid deadlocking device10 and lever and 12v electrohandle mechanical access control9 Mico 942 2-w ay panic exit Key and lever handle SATE AD / device w ith USCH 3 automatic deadlocking
83
Tindall Engineering Limited
84
Tindall Engineering Limited
85
Tindall Engineering Limited
86
Tindall Engineering Limited
87
Tindall Engineering Limited
88
Tindall Engineering Limited
Mico 942P SATE AD / USCH 3
2-w ay emergency exit device w ith automatic deadlocking
Key and lever handle
Push pad
89
Tindall Engineering Limited
Mico 942L SATE AD / USCH 3
2-w ay emergency exit device w ith automatic deadlocking
Key and lever handle
Lever handle
Push plate
-
Push pad
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
Push pad
-
Lever handle
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
Lever handle
-
Panic bar
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 90
Tindall Engineering Limited
Mico 942 SATE MD / USCH 3
2-w ay panic exit device w ith manual deadlocking
Key and lever handle
Panic bar
91
Tindall Engineering Limited
Mico 942P SATE MD / USCH 3
2-w ay emergency Key and lever handle exit device w ith manual deadlocking
Push pad
92
Tindall Engineering Limited
Mico 942L SATE MD / USCH 3
2-w ay emergency Key and lever handle exit device w ith manual deadlocking
Lever handle
93
Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited
Mico 942 /EURO ELK 3 Mico 942P /EURO ELK 3 Mico 942L /EURO ELK 3 Mico 942 EPC EM SEC /USCH 3
2-w ay panic exit device
Key (via ELK 3) and lever handle
Panic bar
2-w ay emergency exit device
Key (via ELK 3) and lever handle
Push pad
S, T, U, V, W, X, Y, Z and AA
2-w ay emergency exit device
Key (via ELK 3) and lever handle
Lever handle
S, T, U, V, W, X, Y, Z and AA
Electro-mechanical 2- w ay locking system w ith solenoid access control deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical access control device w ith thumb turn override and push plate
AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
97
Tindall Engineering Limited
Electro-mechanical Mico 942 EPC 2- w ay locking access control system w ith solenoid EM SEC deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push plate
-
98
Tindall Engineering Limited
Mico 942P EPC 2- w ay locking Electro-mechanical EM SEC /USCH system w ith solenoid access control 3 deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical access control device w ith thumb turn override and push pad
AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
99
Tindall Engineering Limited
Mico 942P EPC 2- w ay locking Electro-mechanical access control EM SEC system w ith solenoid deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push pad
-
100
Tindall Engineering Limited
Mico 942L EPC 2- w ay locking Electro-mechanical access control EM SEC /USCH system w ith solenoid 3 deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical access control device w ith thumb turn override and lever handle
AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
94
95
96
20 Nov 2011
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC S, T, U, V, W, X, Y, Z and AA
311
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 101
Tindall Engineering Limited
Mico 942L EPC 2- w ay locking Electro-mechanical EM SEC system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and lever handle
-
102
Tindall Engineering Limited
Mico 942L EPC 2-w ay locking INT AD /USCH system w ith 3 automatic deadlocking
Key and lever handle
Key or thumb turn and lever handle
103
Tindall Engineering Limited
Key or thumb turn and lever handle
104
Tindall Engineering Limited
None Mico 942L EPC 2-w ay locking INT AD system w ith automatic deadlocking Mico 942 EPC 2-w ay locking Key and lever handle INT MD /USCH system w ith manual 3 deadlocking
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
105
Tindall Engineering Limited Tindall Engineering Limited
Mico 942 EPC 2-w ay locking None INT MD system w ith manual deadlocking Key and lever handle Mico 942P EPC 2-w ay locking INT MD /USCH system w ith manual 3 deadlocking
Key or thumb turn and push plate
107
Tindall Engineering Limited
Mico 942P EPC 2-w ay locking INT MD system w ith manual deadlocking
108
Tindall Engineering Limited
Mico 942L EPC 2-w ay locking Key and lever handle INT MD /USCH system w ith manual 3 deadlocking
Key or thumb turn and lever handle
109
Tindall Engineering Limited Tindall Engineering Limited
Mico 942L EPC 2-w ay locking INT MD system w ith manual deadlocking Mico 942 EPC 2- w ay panic exit SATE EM SEC device w ith solenoid /USCH 3 deadlocking and 12v electro-mechanical access control9 Mico 942 EPC 2- w ay panic exit SATE EM SEC device w ith solenoid deadlocking and 12v electro-mechanical access control9
None
Key or thumb turn and lever handle
Electro-mechanical access control device10 w ith key override and lever handle Electro-mechanical access control device10 and lever handle
Push plate
S, T, U, V, W, X, Y, Z and AA
Push plate
-
106
110
111
312
Tindall Engineering Limited
None
Key or thumb turn and push plate
Key or thumb turn and push pad
Key or thumb turn and push pad
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 112
Tindall Engineering Limited
113
Tindall Engineering Limited
114
Tindall Engineering Limited
115
Tindall Engineering Limited
116
Tindall Engineering Limited
117
Tindall Engineering Limited
118
Tindall Engineering Limited
119
Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited
120
121
122
123
20 Nov 2011
Mico 942P EPC 2- w ay emergency SATE EM SEC exit device w ith /USCH 3 solenoid deadlocking and 12v electromechanical access control9 Mico 942P EPC 2- w ay emergency SATE EM SEC exit device w ith solenoid deadlocking and 12v electromechanical access control8 Mico 942L EPC 2- w ay emergency SATE EM SEC exit device w ith /USCH 3 solenoid deadlocking and 12v electromechanical access control9 Mico 942L EPC 2- w ay emergency SATE EM SEC exit device w ith solenoid deadlocking and 12v electromechanical access control9 Mico 942 EPC 2-w ay panic exit SATE AD / device w ith USCH 3 automatic deadlocking Mico 942P EPC 2-w ay emergency SATE AD / exit device w ith USCH 3 automatic deadlocking Mico 942L EPC 2-w ay emergency SATE AD / exit device w ith USCH 3 automatic deadlocking Mico 942 EPC 2-w ay panic exit SATE MD / device w ith manual USCH 3 deadlocking Mico 942P EPC 2-w ay emergency SATE MD / exit device w ith USCH 3 manual deadlocking Mico 942L EPC 2-w ay emergency SATE MD / exit device w ith USCH 3 manual deadlocking Mico 942-3 3-w ay panic exit /ELK 3 device Mico 942-3
3-w ay panic exit device
Electro-mechanical access control device9 w ith key override and lever handle
Push pad
S, T, U, V, W, X, Y, Z and AA
Electro-mechanical access control device10 and lever handle
Push pad
-
Electro-mechanical access control device10 w ith key override and lever handle
Lever handle
S, T, U, V, W, X, Y, Z and AA
Electro-mechanical access control device10 and lever handle
Lever handle
-
Key and lever handle
Panic bar
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Push pad
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Lever handle
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Panic bar
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Push pad
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Lever handle
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Panic bar
None
Panic bar
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q and R -
313
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 124
Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited
Mico 942-3P /ELK 3
3-w ay emergency exit device
Key and lever handle
Push pad
Mico 942-3P
3-w ay emergency exit device
None
Push pad
Mico 942-3L /ELK 3
3-w ay emergency exit device
Key and lever handle
Lever handle
Mico 942-3L
3-w ay emergency exit device
None
Lever handle
Mico 942-3 EM SEC /USCH 3
Electro-mechanical 3- w ay locking access control system w ith solenoid deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical A, B, C, D, E, F, G, H, I, J, K, L, M, N, access control O, P, Q, R, AW, device w ith thumb AX, AY, AZ, BA, turn override and BB and BC push plate
129
Tindall Engineering Limited
Mico 942-3 EM SEC
Electro-mechanical 3- w ay locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push plate
130
Tindall Engineering Limited
Electro-mechanical Mico 942-3P 3- w ay locking access control EM SEC /USCH system w ith solenoid 3 deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
131
Tindall Engineering Limited
Mico 942-3P EM SEC
132
Tindall Engineering Limited
Electro-mechanical 3- w ay locking Mico 942-3L EM SEC /USCH system w ith solenoid access control 3 deadlocking and 12v device9 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical A, B, C, D, E, F, G, H, I, J, K, L, M, N, access control O, P, Q, R, AW, device w ith thumb AX, AY, AZ, BA, turn override and BB and BC lever handle
133
Tindall Engineering Limited
Mico 942-3L EM SEC
Electro-mechanical access control device w ith thumb turn override and lever handle
134
Tindall Engineering Limited
Mico 942-3L 3-w ay locking INT AD /USCH system w ith 3 automatic deadlocking
125
126
127
128
314
Electro-mechanical 3- w ay locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
3- w ay locking Electro-mechanical access control system w ith solenoid deadlocking and 12v device10 and lever electro-mechanical handle access control8
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q and R -
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q and R -
-
Electro-mechanical A, B, C, D, E, F, G, H, I, J, K, L, M, N, access control O, P, Q, R, AW, device w ith thumb AX, AY, AZ, BA, turn override and BB and BC push pad Electro-mechanical access control device w ith thumb turn override and push pad
-
-
Key and lever handle Thumb turn and lever A, B, C, D, E, F, G, handle H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES None
Thumb turn and lever handle
-
Key (via USCH 3) and lever handle
Key or thumb turn and push plate
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
135
Tindall Engineering Limited
136
Tindall Engineering Limited
3-w ay locking system w ith automatic deadlocking Mico 942-3 INT 3-w ay locking MD /USCH 3 system w ith manual deadlocking
137
Tindall Engineering Limited Tindall Engineering Limited
Mico 942-3 INT 3-w ay locking None MD system w ith manual deadlocking Mico 942-3P 3-w ay locking Key and lever handle INT MD /USCH system w ith manual 3 deadlocking
Key or thumb turn and push plate
Tindall Engineering Limited Tindall Engineering Limited
Mico 942-3P INT MD
3-w ay locking None system w ith manual deadlocking Mico 942-3L 3-w ay locking Key and lever handle INT MD /USCH system w ith manual 3 deadlocking
Key or thumb turn and push pad
Tindall Engineering Limited Tindall Engineering Limited
Mico 942-3L INT MD
None
Key or thumb turn and lever handle
Electro-mechanical access control device10 w ith key override and lever handle Electro-mechanical access control device10 and lever handle
Push plate
Electro-mechanical access control device10 w ith key override and lever handle
Push pad
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
Electro-mechanical access control device10 and lever handle
Push pad
-
138
139
140
141
142
Mico 942-3L INT AD
Mico 942-3 SATE EM SEC /USCH 3
143
Tindall Engineering Limited
Mico 942-3 SATE EM SEC
144
Tindall Engineering Limited
Mico 942-3P SATE EM SEC /USCH 3
145
Tindall Engineering Limited
Mico 942-3P SATE EM SEC
20 Nov 2011
3-w ay locking system w ith manual deadlocking 3- w ay panic exit device w ith solenoid deadlocking and 12v electro-mechanical access control9 3- w ay panic exit device w ith solenoid deadlocking and 12v electro-mechanical access control9 3- w ay emergency exit device w ith solenoid deadlocking and 12v electromechanical access control9 3- w ay emergency exit device w ith solenoid deadlocking and 12v electromechanical access control9
Key or thumb turn and push pad
Key or thumb turn and lever handle
Push plate
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC -
315
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 146
Tindall Engineering Limited
147
Tindall Engineering Limited
148
Tindall Engineering Limited
149
Tindall Engineering Limited
Mico 942-3P SATE AD / USCH 3
3-w ay emergency exit device w ith automatic deadlocking
Key and lever handle
Push pad
150
Tindall Engineering Limited
Mico 942-3L SATE AD / USCH 3
3-w ay emergency exit device w ith automatic deadlocking
Key and lever handle
Lever handle
151
Tindall Engineering Limited
Mico 942-3 SATE MD / USCH 3
3-w ay panic exit device w ith manual deadlocking
Key and lever handle
Panic bar
152
Tindall Engineering Limited
Mico 942-3P SATE MD / USCH 3
3-w ay emergency Key and lever handle exit device w ith manual deadlocking
Push pad
153
Tindall Engineering Limited
Mico 942-3L SATE MD / USCH 3
3-w ay emergency Key and lever handle exit device w ith manual deadlocking
Lever handle
154
Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited
Mico 942-3 /EURO ELK 3
3-w ay panic exit device
Key and lever handle
Panic bar
Mico 942-3P /EURO ELK 3
3-w ay emergency exit device
Key and lever handle
Push pad
S, T, U, V, W, X, Y, Z and AA
Mico 942-3L /EURO ELK 3
3-w ay emergency exit device
Key and lever handle
Lever handle
S, T, U, V, W, X, Y, Z and AA
Mico 942-3 EPC EM SEC /USCH 3
Electro-mechanical 3- w ay locking system w ith solenoid access control deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical access control device w ith thumb turn override and push plate
AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
155
156
157
316
Electro-mechanical 3- w ay emergency Mico 942-3L SATE EM SEC exit device w ith access control /USCH 3 solenoid deadlocking device10 w ith key override and lever and 12v electrohandle mechanical access control9 Mico 942-3L 3- w ay emergency Electro-mechanical SATE EM SEC exit device w ith access control solenoid deadlocking device10 and lever and 12v electrohandle mechanical access control9 Mico 942-3 3-w ay panic exit Key and lever handle SATE AD / device w ith USCH 3 automatic deadlocking
Lever handle
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC
Lever handle
-
Panic bar
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, AW, AX, AY, AZ, BA, BB and BC S, T, U, V, W, X, Y, Z and AA
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 158
Tindall Engineering Limited
Mico 942-3 EPC EM SEC
Electro-mechanical 3- w ay locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9 Electro-mechanical 3- w ay locking system w ith solenoid access control deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical access control device w ith thumb turn override and push plate Electro-mechanical access control device w ith thumb turn override and push pad
159
Tindall Engineering Limited
Mico 942-3P EPC EM SEC /USCH 3
160
Tindall Engineering Limited
Mico 942-3P EPC EM SEC
Electro-mechanical 3- w ay locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and push pad
-
161
Tindall Engineering Limited
Mico 942-3L EPC EM SEC /USCH 3
Electro-mechanical 3- w ay locking system w ith solenoid access control deadlocking and 12v device10 w ith key electro-mechanical override and lever access control9 handle
Electro-mechanical access control device w ith thumb turn override and lever handle
AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
162
Tindall Engineering Limited
Mico 942-3L EPC EM SEC
Electro-mechanical 3- w ay locking system w ith solenoid access control deadlocking and 12v device10 and lever electro-mechanical handle access control9
Electro-mechanical access control device w ith thumb turn override and lever handle
-
163
Tindall Engineering Limited
Mico 942-3L EPC INT AD /USCH 3
3-w ay locking system w ith automatic deadlocking
Key and lever handle
Key or thumb turn and lever handle
164
Tindall Engineering Limited
Mico 942-3L EPC INT AD
Key or thumb turn and lever handle
165
Tindall Engineering Limited
Mico 942-3 EPC INT MD /USCH 3
3-w ay locking None system w ith automatic deadlocking 3-w ay locking Key and lever handle system w ith manual deadlocking
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
166
Tindall Engineering Limited Tindall Engineering Limited
Mico 942-3 EPC INT MD
3-w ay locking None system w ith manual deadlocking 3-w ay locking Key and lever handle system w ith manual deadlocking
Key or thumb turn and push plate
167
20 Nov 2011
Mico 942-3P EPC INT MD /USCH 3
Key or thumb turn and push plate
Key or thumb turn and push pad
-
AE, AF, AG, AH, AJ, AL, AN, AP, AR, AT and AV
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV
317
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 168
Tindall Engineering Limited Tindall Engineering Limited
Mico 942-3P EPC INT MD
Tindall Engineering Limited Tindall Engineering Limited
Mico 942-3L EPC INT MD
172
Tindall Engineering Limited
Mico 942-3 EPC SATE EM SEC
173
Tindall Engineering Limited
Mico 942-3P EPC SATE EM SEC /USCH 3
174
Tindall Engineering Limited
Mico 942-3P EPC SATE EM SEC
175
Tindall Engineering Limited
Mico 942-3L EPC SATE EM SEC /USCH 3
176
Tindall Engineering Limited
Mico 942-3L EPC SATE EM SEC
177
Tindall Engineering Limited
Mico 942-3 EPC SATE AD / USCH 3
178
Tindall Engineering Limited
Mico 942-3P EPC SATE AD / USCH 3
169
170
171
318
Mico 942-3L EPC INT MD /USCH 3
Mico 942-3 EPC SATE EM SEC /USCH 3
3-w ay locking None system w ith manual deadlocking 3-w ay locking Key and lever handle system w ith manual deadlocking
Key or thumb turn and push pad
-
Key or thumb turn and lever handle
2-w ay locking None system w ith manual deadlocking Electro-mechanical 3- w ay panic exit access control device w ith solenoid device10 w ith key deadlocking and 12v override and lever electro-mechanical handle access control9 Electro-mechanical 3- w ay panic exit access control device w ith solenoid deadlocking and 12v device10 and lever handle electro-mechanical access control9 Electro-mechanical 3- w ay emergency access control exit device w ith solenoid deadlocking device10 w ith key override and lever and 12v electrohandle mechanical access control9 Electro-mechanical 3- w ay emergency access control exit device w ith solenoid deadlocking device10 and lever handle and 12v electromechanical access control9 Electro-mechanical 3- w ay emergency access control exit device w ith solenoid deadlocking device10 w ith key override and lever and 12v electrohandle mechanical access control9 Electro-mechanical 3- w ay emergency access control exit device w ith solenoid deadlocking device10 and lever handle and 12v electromechanical access control9 3-w ay panic exit Key and lever handle device w ith automatic deadlocking 3-w ay emergency Key and lever handle exit device w ith automatic deadlocking
Key or thumb turn and lever handle
AC, AD, AE, AF, AG, AH, AI, AJ, AK, AL, AM, AN, AO, AP, AQ, AR, AS, AT, AU and AV -
Push plate
S, T, U, V, W, X, Y, Z and AA
Push plate
-
Push pad
S, T, U, V, W, X, Y, Z and AA
Push pad
-
Lever handle
S, T, U, V, W, X, Y, Z and AA
Lever handle
-
Panic bar
S, T, U, V, W, X, Y, Z and AA
Push pad
S, T, U, V, W, X, Y, Z and AA
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 179
Tindall Engineering Limited
180
Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Tindall Engineering Limited Bradbury Security
181
182
183
184
3-w ay emergency Mico 942-3L EPC SATE AD exit device w ith / USCH 3 automatic deadlocking 3-w ay panic exit Mico 942-3 EPC SATE MD device w ith manual / USCH 3 deadlocking Mico 942-3P 3-w ay emergency EPC SATE MD exit device w ith / USCH 3 manual deadlocking Mico 942-3L 3-w ay emergency EPC SATE MD exit device w ith / USCH 3 manual deadlocking HSTB Tw o surface mounted drop bolts -
Key and lever handle
Lever handle
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Panic bar
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Push pad
S, T, U, V, W, X, Y, Z and AA
Key and lever handle
Lever handle
S, T, U, V, W, X, Y, Z and AA
None
Surface mounted drop bolts
-
None
Surface mounted drop bolts
-
Tw o surface mounted drop bolts
Compatible Cylinders
Cylinder Reference A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA
Manufacturer
Model
Type
Abloy Abloy Abloy AMS ASSA ASSA ASSA ASSA ASSA ASSA ASSA ASSA ASSA ASSA Kaba Kaba Locken Medeco ASSA Abloy Abloy Abloy ASSA ASSA ASSA Medico KABA
Protec CY201 PT Disklock Pro CY201 DP Protec Cliq CY201 CL-OVLD 4401dp 4401 Cliq 4407dp 4407 Cliq 4801 4807 C5801 C5807 Tw in 7601 Tw in 7607 K20 Quattro PluS CL-PL2WR M3-ARX 44M23 CY307 Protec CY307 Disclock Pro CY307 Protec Cliq 4823 C5823 7623 M3 ARX Quattro PluS
Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Scandinavian Oval Europrofile single cylinder Europrofile single cylinder Europrofile single cylinder Europrofile single cylinder Europrofile single cylinder Europrofile single cylinder Europrofile single cylinder Europrofile single cylinder Europrofile single cylinder
20 Nov 2011
319
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ BA BB BC
ISEO Abloy Abloy Abloy Abloy Abloy Abloy ASSA ASSA ASSA ASSA ASSA ASSA ASSA ASSA ASSA ASSA Kaba Kaba Medeco Medeco Abloy Abloy Kaba Medeco AMS ASSA ASSA
R6 Protec CY304 Protec Cliq CY304 Protec CY305 Protec Cliq CY305 Protec Cliq CY333 Protec CY333 4422dp 4427dp 44M22 Cliq 44M27 Cliq 4822 4827 C5822 C5827 7622 7627 Quattro PluS Quattro PluS M3-ARX M3-ARX Protec CY403 Protec Cliq CY403 Quattro Plus M3-ARX CL-CA2D 4857 C5857
Europrofile double cylinder (key:key) Europrofile double cylinder (key:key) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Rim Rim Rim Rim Finish Round Round threaded Round threaded
Accessories11
Accessory
Description
Flat sill
3 mm flat plate sill
12
Low profile aluminium sill
Low profile aluminium sill
No sill12
No sill
Vision panel13, 14, 15
356 mm high by 203 mm w ide vision panel incorporating a 45.04 mm thick specialist laminated double glazed security glazing unit 762 mm high by 203 mm w ide vision panel incorporating a 45.04 mm thick specialist laminated double glazed security glazing unit 457 mm high by 457 mm w ide vision panel incorporating a 45.04 mm thick specialist laminated double glazed security glazing unit 356 mm high by 203 mm w ide vision panel incorporating a 45.5 mm thick specialist laminated security glass 762 mm high by 203 mm w ide vision panel incorporating a 45.5 mm thick specialist laminated security glass 457 mm high by 457 mm w ide vision panel incorporating a 45.5 mm thick specialist laminated security glass
12
Notes: 1. When fitted with compatible lock option 1 the security rating applies to doorsets with the locking mechanisms fully engaged, i.e. in optimum locked condition. The single leaf doorset achieves Security Rating 1 when left in the minimum locked condition, i.e. when the key is turned once and removed. The double doorset also achieves Security Rating 1 when left in the minimum locked condition, i.e. only one surface mounted drop bolt on the passive leaf engaged and the key on the active leaf thrown once and removed. 2. When fitted with compatible lock option 2 the security rating is also achieved by the doorset when in the minimum locked condition, i.e. when both surface mounted drop bolts on the passive leaf are disengaged. 3. When fitted with the Mico compatible lock options 3 to182 the security rating applies to doorsets with the locking mechanisms fully engaged, i.e. in optimum locked condition. The single leaf and double leaf doorsets achieve Security Rating 1 when left in the minimum locked condition. 4. The M2M3 double leaf doorsets can be produced with leafs of unequal width. The maximum width of both leafs is 1100 mm. The minimum width of the active leaf is 750 mm. The minimum width of the passive leaf is 400 mm. 5. Although outside the scope of LPS 1175: Issue 7, special consideration should be paid to the use of locking systems with separate deadlocks, e.g. Mico 942-3 INT MD. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or emergency device. For
320
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
6.
7. 8. 9. 10.
11. 12. 13. 14. 15.
further information, please refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively. Although outside the scope of LPS 1175: Issue 7, special consideration should be paid to the use of single operating panic or emergency exit devices. This is because it is generally accepted that when two panic or emergency exit devices are fitted to double doorsets the operation of either device should disengage simultaneously such that both leafs can open. For further information, please refer to the appropriate standard for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively. The two-way locking systems used on the passive leaf of double doorsets shall incorporate identical internal operation devices to those on the locking systems used on the active leaf. Certification does not cover the use of locks other than those listed. Utilisation of unlisted locks may affect the level of security offered by the doorset. Fail secure version only. The resistance of the access control locks to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that Ascot Doors Limited satisfy themselves that the components are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. Certification does not cover the use of vision panels or other accessories that are not listed. Utilisation of other accessories may affect the level of security offered by the doorset. The alternative sill options should not to be fitted to doorsets incorporating panic bars or push pads. The standard (stepped) sill must always be used on doorsets incorporating either glazed apertures or locking mechanisms incorporating single action escape panic exit systems operated by panic bars. Doorsets fitted with upper and lower glazed apertures should not incorporate hardware operated by a panic bar. The 45.04 mm thick specialist laminated double glazed security glazing unit should only be used on doorsets fitted with compatible lock option 1 and options 3 to 182 incorporating internal key deadlocks.
C W Fields and Son Limited Station Road Industrial Estate, Epworth, Nr. Doncaster, South Yorkshire DN9 1JZ, United Kingdom Tel: +44 (0)1427 872368 • Fax: +44 (0)1427 873057 E-mail: [email protected] • Website: www.cwfields.co.uk Certificate No: 940a to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Type
Fields Security
Single leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset with fixed/removable over panels1 Single leaf inward opening hinged security doorset Single leaf inward opening hinged security doorset with fixed/removable over panels1 Double leaf outward opening hinged security doorset2
20 Nov 2011
Minimum Structural Opening Height (m) 0.705
Maximum Structural Opening Height (m) 2.605
Minimum Structural Opening Width (m) 0.382
Maximum Structural Opening Width (m) 0.997
Security Rating
Cert. No.
2
940a/01
0.955
3.055
0.382
0.997
2
940a/02
0.705
2.605
0.382
0.997
2
940a/03
0.955
3.055
0.382
0.997
2
940a/04
0.705
2.605
0.685
1.915
2
940a/05
321
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Product Name
Type
Double leaf outward opening hinged security doorset with fixed/removable over panels1, 2 Double leaf inward opening hinged security doorset2 Double leaf inward opening hinged security doorset with fixed/removable over panels1, 2
Minimum Structural Opening Height (m) 0.955
Maximum Structural Opening Height (m) 3.055
Minimum Structural Opening Width (m) 0.685
Maximum Structural Opening Width (m) 1.915
Security Rating
Cert. No.
2
940a/06
0.705
2.605
0.685
1.915
2
940a/07
0.955
3.055
0.685
1.915
2
940a/08
Approved Locking Configurations
LPCB Ref. No. 940a/01 940a/02 940a/03 940a/04 940a/05 940a/06 940a/07 940a/08
Trade Name Fields Security Fields Security Fields Security Fields Security Fields Security Fields Security Fields Security Fields Security
Com patible Locking System s Type Single leaf outw ard opening hinged security doorset Single leaf outw ard opening hinged security doorset w ith fixed/removable over panels 1 Single leaf inw ard opening hinged security doorset Single leaf inw ard opening hinged security doorset w ith fixed/removable over panels 1 Double leaf outw ard opening hinged security doorset2 Double leaf outw ard opening hinged security doorset w ith fixed/removable over panels 1,2 Double leaf inw ard opening hinged security doorset2 Double leaf inw ard opening hinged security doorset w ith fixed/removable over panels 1,2
Active Leaf
Passive Leaf
1, 2, 3
N/A
1, 2, 3
N/A
1, 2, 3
N/A
1, 2, 3
N/A
1, 2, 3
4
1, 2, 3
4
1, 2, 3
4
1, 2, 3
4
Compatible Locking Systems
322
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Com patible Manufacturer Locking System
Model
Operating Devices
1
Surelock McGill Limited
SL325- E1K2O2 PW
2
Surelock McGill Limited
SL325-E1W
3
Surelock McGill Limited Surelock McGill Limited
SL315- E1K2O2PW
4
TBFW barrel bolts
External Face Electromechanical access control lock (fail secure) w ith key override and lever handle Electromechanical access control lock (fail secure) w ith lever handle Key and lever handle None
Internal Face Single action lever handle
Com patible Cylinders A
Single action lever handle
A
Single action lever handle Tw o barrel bolts
A N/A
Compatible Cylinders
Cylinder Reference
Manufacturer
Model
Type
A
Assa
C5857
Rim cylinder
Vision Panels
Trade Name
Vision Panels
Fields Security
30 mm w ide by 300 mm high vision panels on leafs at least 567 mm w ide.
Com patible Doorset Configurations Single Leaf Inw ard Opening
Single Leaf Outw ard Opening
Double Leaf Inw ard Opening
Double Leaf Outw ard Opening
Notes: 1. The maximum door leaf height is 2558 mm. 2. The scope of this approval includes double leaf doorsets with equal and unequal leafs. The maximum individual leaf width is 915 mm and the minimum individual leaf width is 300 mm.
Clearway Environmental Services (UK) Limited 11 Landau Way, Darent Industrial Park, Erith, Kent DA8 2LF, United Kingdom Tel: +44 (0)1322 332211 • Fax: +44 (0)1322 339582 E-mail: [email protected] • Website: www.clearwayservices.co.uk Certificate No: 1001a to LPS 1175: Issue 7
20 Nov 2011
323
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Temporary Security Doorset Product Name
Configuration
Toreadoor
Single leaf, outward opening, hinged temporary3 security doorset
Minimum Structural Opening Height1 (m) 1.61
Maximum Structural Opening Height1 (m) 1.93
Minimum Structural Opening Width1 (m) 0.37
Maximum Structural Opening Width1 (m) 0.76
Minimum Structural Opening Depth2 (m) 0.045
Maximum Structural Opening Depth2 (m) 0.25
Security Rating
Cert. No.
1
1001a
Compatible Locking Systems4
Manufacturer
Model
Type
Com patible Opening Devices External Face
Internal Face
Willenhall
M1 Clearw ays
5-lever mortice deadlock
Key and handle
Key and handle
Clearw ay
Centurion
Electronic locking system5
Keypad
Manual actuator
Notes: 1. The doorset is available in one fixed size to suit a range of structural opening sizes. 2. Maximum depth of the aperture within the supporting substrate6 that the doorset can be fitted within. 3. The doorset is designed to be fitted to unoccupied properties. 4. Both locking systems are fitted to the doorset. The security rating was achieved by the doorset with only one lock engaged, i.e. the minimum locked condition. The doorset also achieved Security Rating 1 in the optimum locked condition, i.e. with both locks engaged. 5. The resistance of the electronic locking system to “non-mechanical” attack has not been assessed because it is outside the scope of LPS 1175: Issue 7. 6. The doorset is suitable for installation7 into timber, brickwork, steel, blockwork, concrete and aluminium substrates. 7. The doorset should be installed in accordance with the installation instructions ‘Fitting / Fixing instructions for the Toreadoor Keyless Door’ dated 13 October 2011.
Design & Supply Limited 13 Pant Industrial Estate, Merthyr Tydfil, Mid Glamorgan CF48 2SR, United Kingdom Tel: +44 (0)1685 350114 • Fax: +44 (0)1685 723276 E-mail: [email protected] Certificate No: 694b to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Type
Desray
Single leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset1
Minimum Structural Opening Height (m) 1.8
Maximum Structural Opening Height (m) 2.2
Minimum Structural Opening Width (m) 0.75
Maximum Structural Opening Width (m) 1.1
Security Rating
Cert. No.
2
694b/01
1.8
2.2
1.5
2.5
2
694b/02
Approved Locking Configurations
LPCB Ref. No.
Product Nam e
Type
694b/01
Desray
694b/02
Desray
Single leaf outw ard opening hinged security doorset Double leaf outw ard opening hinged security doorset
324
Com patible Locking System Active Leaf
Passive Leaf
1, 2, 3, 4, 6, 7, 8
-
1, 2, 3, 4, 6, 7, 8
52, 9
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Compatible Locking Systems
Com patible Manufacturer Locking System s
Model
Type
1
Assa
765
Sash lock
2
Assa
765
Sash lock
3
Assa
2788
4
Assa
2788
5
Exidor
802
6
Exidor
803
7
Exidor
803 w ith 809
8
Exidor
803 w ith 810
9
Exidor
HS923/10
Com patible Operating Devices External Face Internal Face
Com patible Cylinder
Dead lock
Key and lever handle Key and lever handle Key
Key and lever handle Thumbturn and lever handle Key
A
Dead lock
Key
Thumbturn
B
Tw o point panic exit device Three point panic exit device3 Three point panic exit device w ith outside access device3 Three point panic exit device w ith outside access device3 Tw o tow er bolts
None
Panic bar
N/A
None
Panic bar
N/A
Key via Exidor 809 outside access device Key via Exidor 810 outside access device None
Panic bar
C
Panic bar
C
Tow er bolts
N/A
B A
Compatible Cylinders
Cylinder Reference A
Manufacturer
Model
Type
Assa
C5802
Double oval cylinder (key:key)
B
Assa
C5801
Double oval cylinder (key:thumbturn)
C
Zone
1850
Single europrof ile cylinder
Accessories
Accessory
Description
Sherman vision panel4
40.5 mm thick vision panels of maximum dimensions 400 mm by 400 mm. These may either be located central to the w idth of the leaf or offset from leading edge by 150 mm. 27.8 mm thick vision panels of maximum dimensions 400 mm by 400 mm. These may either be located central to the w idth of the leaf or offset from leading edge by 150 mm. 27 mm thick vision panels of maximum dimensions 400 mm by 400 mm. These may either be located central to the w idth of the leaf or offset from leading edge by 150 mm.
Chieftain vision panel4
AB26 vision panel
EXECDOOR doorsets 694b/01
694b/02
The following table confirms which combinations of vision panel and locking system may be used together.
Com patible Locking System s 1
Com patible Vision Panels Sherman, Chieftain and AB26
2
Sherman and AB26
3
Sherman, Chieftain and AB26
4
Sherman and AB26
5
Sherman and AB26
6
Sherman and AB26
7
Sherman and AB26
8
Sherman and AB26
9
Sherman, Chieftain and AB26
Notes:
20 Nov 2011
325
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 1. Double leaf Desray doorsets may incorporate leafs of equal or unequal width. Leafs of unequal width will comprise of an active leaf exactly twice as wide as the passive leaf. The maximum leaf width is 1350 mm and the minimum leaf width is 500 mm. 2. This locking system may only be used on the passive leaf and then only if locking systems 6, 7 or 8 are used on the active leaf. 3. Locking systems 6, 7 and 8 may not comply with fire escape regulations relating to potential panic situations if fitted to double leaf doorsets. This is because activation of the device on one leaf may not necessarily release the other leaf and in some cases may not release the leaf to which it is fitted. 4. These vision panels incorporate obscurable panels controlled by a handle on the protected side of the doorset.
IR Martin Roberts, IR Security & Safety Limited Millen Road, Sittingbourne, Kent ME10 2AA, United Kingdom Tel: +44 (0)1795 476161 • Fax: +44 (0)1795 422463 E-mail: [email protected] • Website: www.irmartinroberts.co.uk Certificate No: 322a to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
Martin Roberts SD5003 Range Martin Roberts SD5001
Single leaf, outward opening hinged security doorset Single leaf, outward opening hinged security doorsets Single leaf, inward opening hinged security doorsets
Minimum Clear Opening Height (m) 0.951
Maximum Clear Opening Height (m) 3.049
Minimum Clear Opening Width (m) 0.503
Maximum Clear Opening Width (m)
Security Rating
Cert. No.
1.322
3
322a/01
0.951
3.049
0.503
1.322
1
322a/02
0.951
2.25
0.503
1.322
1
Approved Locking Configurations
LPCB Ref. No.
Trade Nam e
Type
Com patible Locking System s
322a/01
Martin Roberts SD5003
Single leaf, outw ard opening hinged security doorset
1, 2, 4, 6, 7, 8, 9, 10, 11, 12 and 13
322a/02
Martin Roberts SD50011 Single leaf, outw ard opening hinged security doorset Single leaf, inw ard opening hinged security doorset
5 3
Compatible Locking Systems
Option Locking System 1
Assa 765
2
Assa 500/9
3
Assa 1520
4
Assa 8761
326
Type
Com patible External and Internal Operating Devices External Internal Sash Lock Key via an Assa 6501 single Key plus lever handle cylinder or an Assa 6502 double or cylinder Key plus thumb-turn Mortice Locking Latch Key via an Assa 6501 single Assa Mico 944 panic latch cylinder or Briton 379 panic operator or Lever handle Escape Sash Lock Key via an Assa 4801 single Assa 6650C solid brass handle cylinder plus either: or Assa 6256 thumbturn Key via an Assa 4802 double or cylinder Key via an Assa 4802 double cylinder Emergency Nightlatch Key via an Assa 6501 single Assa Mico 944 panic latch cylinder or Briton 379 panic operator or Lever handle
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 5
Assa 8761
6
Assa 9788
72
Assa 8761 and Assa 9788
Emergency Nightlatch Key via an Assa 4801 single cylinder Mortice Deadlock Key via an Assa 6501 single cylinder or an Assa 6502 double cylinder Emergency Nightlatch Tw o separate keys via Assa and 6501 or Assa 6502 cylinders Mortice Deadlock
8
Assa 9788 (Tw o fitted)
Mortice Deadlocks
9
Security Engineering plc Sash Lock SI1216
10
11
122
13
Key via an Assa 6501 single or Assa 6502 double cylinder
Key via a Buga 4600 single cylinder or a Buga 4610 double cylinder Security Engineering plc Emergency Nightlatch Key via a Buga 4600 single SI1233 cylinder
Security Engineering plc Mortice Deadlock SI1241
Key via a Buga 4600 single cylinder or a Buga 4610 double cylinder Security Engineering plc Emergency Nightlatch Tw o separate keys via Buga SI 1233 and SI 1241 and Mortice Deadlock 4600 or Buga 4610 cylinders
SI 1241 (tw o fitted)
Mortice Deadlocks
Key via a Buga 4600 single or Buga 4610 double cylinder
Assa 640 solid brass handle Key or Thumb-turn Combination of either: Assa Mico 944 panic latch, Briton 379 panic operator or Lever handle, and either: key or thumb-turn Tw o keys or Tw o thumb-turns or One key and one thumb-turn Key plus lever handle or Key plus thumb-turn Assa Mico 944 panic latch or Briton 379 panic operator or Lever handle Key or Thumb-turn Combination of either: Assa Mico 944 panic latch, Briton 379 panic operator or Lever handle, and either: key or thumb-turn Tw o keys or Tw o thumb-turns or One key and one thumb-turn
Notes: 1. The Martin Roberts SD5001 also meets the requirements of PAS23-1:1999 and PAS24-1:1999. For further information, please refer to entries in sections on PAS23-1 and PAS24-1 relating to LPCB certificates 322b and 322c respectively. 2. Although outside the scope of LPS1175: Issue 5, special consideration should be paid to the use of the Assa 9788 Mortice Deadlock in combination with the Assa 8761 Emergency Nightlatch or the SI1241 Mortice Deadlock in combination with the SI1233 Emergency Nightlatch. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or emergency device. For further information, please refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively. Certificate No: 322d to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Doorset Configuration
SD5002-01
Single plain leaf outward opening doorset Double plain leaf outward opening doorset
SD5002-02
Minimum Clear Opening Height (m) 1.7
Maximum Clear Opening Height (m) 2.25
Minimum Clear Opening Width (m) 0.7
Maximum Clear Opening Width (m) 1.2
Security Rating
Cert. No.
2
322d/01
1.9
2.25
1.4
2.5
21
322d/02
Compatible Locking Configurations
20 Nov 2011
327
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Product Name Doorset Configuration
Com patible Locking System s Active Leaf
Passive Leaf
SD5002-01
Single plain leaf outw ard opening doorset
1
N/A
SD5002-02
Double plain leaf outw ard opening doorset
2
3
Compatible Locking Systems
Com patible Manufacturer Model Locking System s
Type
Com patible Operating Devices
Com patible Cylinders
External Face Key and lever handle
Internal Face Thumbturn and lever handle
CISA 52526-60-0 double europrofile cylinder
Thumbturn and lever handle
CISA 52526-60-0 double europrofile cylinder
1
Briton
5520
Sash lock
2
CISA
52526-60-0 and 06453-05-0
Mortice deadlock Key and and sw ing bolts lever handle
3
Exidor
HS923
Drop bolts
N/A
N/A
N/A
Note: 1. In order to provide the certified level of resistance to forced entry, the key must be rotated through 720 degrees, to fully engage the bolts before removing it from the cylinder, and both drop bolts must be engaged. Security rating 1 classification prevails if the key is only turned once through 360 degrees before removing.
Liddle Doors Limited Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698 E-mail: [email protected] • Website: www.liddledoors.co.uk Certificate No: 442a to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
Minimum Height (m)
Minimum Width (m)
Maximum Height (m)
Maximum Width (m)
Security Rating
Cert. No.
LD Series 4
Single leaf, outward opening hinged security doorset
1.8
0.75
2.25
1.15
4
442a/01
Compatible Locking Devices
LPCB Ref. No. 442a/01
Trade Type Nam e LD Series 4 Single leaf hinged outw ard opening hinged security doorset
Lock
Cylinder
Surelock McGill C3 3-w ay multiple bolting unit
Abloy 5841 Europrofile single cylinder w ith internal thumbturn
Certificate No: 442b to LPS 1175: Issue 6
328
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Hinged Security Doorsets Product Name
Type
Minimum Height (m)
Maximum Height (m)
Minimum Width (m)
Maximum Width (m)
Security Rating
Cert. No.
Liddle Series 3
Single leaf outward opening hinged doorset Double leaf 1 outward opening hinged doorset
1.8
2.2
0.75
1.2
3
442b/01
1.8
2.2
1.4
2.0
3
442b/02
Approved Locking Configurations
Cert. No.
Product Name
442b/01
Liddle Series 3
442b/02
Liddle Series 3
Type
Compatible Locking Systems
Single leaf outw ard opening hinged doorset Double leaf outw ard opening hinged doorset
Active leaf
Passive Leaf
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
N/A 12
Compatible Locking Systems
Com patible Locking System
Manufacturer
1
Surelock McGill
Stirling EX800
2
Surelock McGill
ST105-0X-W3 Stirling EX800
Model
ST115-0XK13O0PW3
3
Surelock McGill
Stirling DL800
4
Surelock McGill
ST103-0X-W3 Stirling DL800 ST113-0XK13O0PW3
20 Nov 2011
Type
Com patible Operating Device
Compatible Cylinders
External Face None
Not applicable
Internal Face Lever handle
Single point surface mounted emergency exit device Key plus lever Lever handle Single point surface handle mounted emergency exit device w ith external access via a cylinder protected by an ‘SR3’ cylinder guard Single point surface None Thumb turn mounted deadlock plus lever handle Key plus lever Thumb turn Single point surface handle plus lever mounted deadlock w ith handle external access via a cylinder protected by an ‘SR3’ cylinder guard
A, B, C, D, E
Not applicable
A, B, C, D, E
329
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 5
Surelock McGill
Stirling AC800 ST102-0X-W3
6
Surelock McGill
Stirling AC800 ST122-0X-W3
7
Surelock McGill
Stirling AC800 ST122-0XK13O0PW3
Single point surface mounted electromechanical access control lock pow ered by 12 V, 24 V or 50 V failsecure solenoid2 Single point surface mounted electromechanical access control lock pow ered by 12 V, 24 V or 50 V failsecure solenoid2 Single point surface mounted electromechanical access control lock pow ered by 12 V, 24 V or 50 V failsecure solenoid2 w ith external key override via a cylinder protected by an ‘SR3’ cylinder guard
None
Lever handle plus access control2
Not applicable
Lever handle Lever handle plus access plus access control2 control2
Not applicable
Lever handle Lever handle plus access plus either key or access control2 control2
A, B, C, D, E
8
Surelock McGill
Stirling EX800
Single point surface mounted emergency exit ST105-0X-H3W3 device
None
Push pad
Not applicable
9
Surelock McGill
Stirling EX800
Key plus lever handle
Push pad
A, B, C, D, E
10
Surelock McGill
Lever handle plus access control2
Push pad plus access control2
Not applicable
11
Surelock McGill
Single point surface mounted emergency exit ST115-OXdevice w ith external H3K13O0PW3 access via a cylinder protected by an ‘SR3’ cylinder guard Stirling AC800 Single point surface mounted electroST125-0X-H3W3 mechanical access control lock pow ered by 12 V, 24 V or 50 V failsecure solenoid2 Stirling AC800 Single point surface mounted electroST125-0Xmechanical access H3K13O0PW3 control lock pow ered by 12 V, 24 V or 50 V failsecure solenoid2 w ith external key override via a cylinder protected by an ‘SR3’ cylinder guard
Push pad Lever handle plus access plus either key or access control2 control2
A, B, C, D, E
12
Surelock McGill
Surelock TA tow er bolt
-
Tow er bolt3
-
Not applicable
Compatible Cylinders
Cylinder Reference
Manufacturer
Model
Type
A
Abloy
CY403 PT
Rim cylinder
B
Abloy
CY405 PT
Rim cylinder
C
Assa
4857
Rim cylinder
D
Assa
C5857
Rim cylinder
E
Kaba
KV06.100
Rim cylinder
Notes: 1. The scope covers double doorsets formed with two leafs of equal widths.
330
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 2. The resistance of the access control locks to ‘non-mechanical’ attack was not assessed as it is outside the scope of LPS1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any access control equipment used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is ‘infinite’. It is therefore recommended that customer satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 3. Two tower bolts are fitted.
Lowrey Contractors Limited 200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111 E-mail: [email protected] • Website: www.lowrey-contractors.co.uk Certificate No: 974d to LPS 1175: Issue 7
Hinged Security Doorsets Product Name
Product Type
Lowrey Level 4 Single Leaf Security Doorset Lowrey Level 4 Double Leaf Security Doorset
Single leaf outward opening plain leaf doorset Double leaf outward opening plain leaf doorset
Minimum Height (m) 1.0
Maximum Height (m) 2.4
Minimum Width (m) 0.6
Maximum Width (m) 1.3
Security Rating 4
Cert. No. 974d/01
1.0
2.4
1.2
2.6
4
974d/02
Compatible Locking Devices1, 2
Manufacturer
Locking Device
Type
Cylinder
Abloy
PL330/25 (V01) HP
Padlock
Abloy High Profile
Abloy
PL330/25 (V01) EX
Padlock
Abloy Exec
Abloy
PL330/25 (V01) PT
Padlock
Abloy Protec
Abloy
PL340/25 (V01) HP
Padlock
Abloy High Profile
Abloy Exec
Abloy
Approved Product (LPCB Ref. No. 974d/..) 1 2
PL340/25 (V01) EX
Padlock
Abloy
PL340/25 (V01) PT
Padlock
Protec
Abloy
PL342 (V01) HP
Padlock
Abloy High Profile
Abloy
PL342 (V01) EX
Padlock
Abloy Exec
Abloy Protec
Abloy
PL342 (V01) PT
Padlock
Abloy
PL350/25 (V01) HP
Padlock
Abloy High Profile
Abloy
PL350/25 (V01) EX
Padlock
Abloy Exec
Abloy
PL350/25 (V01) PT
Padlock
Abloy Protec
Kaba
Kaba K18 w ith 11 mm open shackle (Item No. K180010-SS) Kaba K2010
Padlock
Kaba K20-C5
Padlock
Kaba K20 (Armoured) 3
Pickersgill-Kaye Kaye-Rota L8637-901 ST
Padlock
Kaba K20 (Armoured)
3
Pickersgill-Kaye Kaye-Rota L8637-902 SE
Padlock
Kaba K20 (Armoured)
3
Kaba
Notes: 1. Certification does not cover the use of locks other than those listed. Utilisation of unlisted locks may affect the level of security offered by the doorset. 2. The ‘user friendliness’ of employing the padlocks listed has not been assessed as this is beyond the scope of LPS 1175: Issue 7. 3. The torque resistant version of the Kaba K20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders. 4. The Lowrey plain leaf doorsets are approved when installed in accordance with the instructions detailed on Lowrey document E-INST004 (Issue 8).
20 Nov 2011
331
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
Powershield Doors Limited 21 Ferguson Drive, Knockmore Hill Industrial Park, Lisburn, Northern Ireland BT28 2EX, United Kingdom Tel: +44 (0)28 9266 2200 • Fax: +44 (0)28 9260 3600 E-mail: [email protected] • Website: www.powershield.co.uk Certificate No: 852a to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Type
Powershield Class 3 single Powershield Class 3 double
Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset2 Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset2
Powershield Class 4 single Powershield Class 4 double
Minimum Structural Opening Height (m) 1.8
Maximum Structural Opening Height (m) 2.4
Minimum Structural Opening Width (m) 0.75
Maximum Structural Opening Width (m) 1.2
Security Rating1
Cert. No.
3
852a/01
1.8
2.4
1.4
2.4
3
852a/02
1.8
2.4
0.75
1.2
4
852a/03
1.8
2.4
1.4
2.4
4
852a/04
Approved Locking Configurations
LPCB Ref. No.
Trade Name
Type
Compatible Locking Systems Active Leaf
Passive Leaf
852a/01
Powershield Class 3 single
Single leaf, outward opening hinged security doorset
1 to 58
N/A
852a/02
Powershield Class 3 double
Double leaf, outward opening hinged security doorset
1 to 58
67
852a/03
Powershield Class 4 single
Single leaf, outward opening hinged security doorset
11, 13, 15, 17 , 40, 42, 44, 46 59, 60, 61, 62, 63, 64, 65 and 66
N/A
852a/04
Powershield Class 4 double
Double leaf, outward opening hinged security doorset
11, 13, 15, 17 , 40, 42, 44, 46 59, 60, 61, 62, 63, 64, 65 and 66
67
Compatible Locking Systems Compatible Locking Systems 1 2 3 4
332
Model4
Type
Operation Entry
MICO 942-3 / EURO ELK 3 MICO 942-3P / EURO ELK 3 MICO 942-3L / EURO ELK 3 MICO 942-3 EPC EM SEC / HSCH 3
3-way panic exit device 3-way emergency exit device 3-way emergency exit device 3-way locking system with solenoid deadlock and electromechanical access control powdered by 12v.
External Cylinder Exit
Key via EURO ELK 3
Panic exit push plate
A, B, C, D, E and F
Key via EURO ELK 3
Push pad
A, B, C, D, E and F
Key via EURO ELK 3
Lever handle
A, B, C, D, E and F
Access control system (e.g. key pad or swipe card) not specified3 or key override via Europrofile cylinder within the HSCH3 cylinder guard and lever handle
Internal access control and thumb turn override via Europrofile cylinder with push plate
A, B, C, D, E and F
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES -
5
MICO 942-3 EPC EM SEC
3-way locking system Access control system (e.g. with solenoid key pad or swipe card) not deadlock and specified3 and lever handle electromechanical access control powdered by 12v.
Access control and thumb turn override via Europrofile cylinder with push plate
6
MICO 942-3P EPC EM SEC / HSCH 3
3-way locking system with solenoid deadlock and electromechanical access control powdered by 12v.
A, B, C, D, E and F Access control and thumb turn override via Europrofile cylinder with push pad
7
MICO 942-3P EPC EM SEC
3-way locking system Access control system (e.g. with solenoid key pad or swipe card) not deadlock and specified3 and lever handle electromechanical access control powdered by 12v.
Access control and thumb turn override via Europrofile cylinder with push pad
8
MICO 942-3L EPC EM SEC / HSCH 3
3-way locking system with solenoid deadlock and electromechanical access control powdered by 12v.
Access control system (e.g. key pad or swipe card) not specified3 or key override via Europrofile cylinder within the HSCH3 cylinder guard and lever handle
Access control and thumb turn override via Europrofile cylinder with lever handle
A, B, C, D, E and F
9
MICO 942-3L EPC EM SEC
3-way locking system Access control system (e.g. key pad or swipe card) not with solenoid deadlock and specified3 and lever handle electromechanical access control powdered by 12v.
Access control and thumb turn override via Europrofile cylinder with lever handle
-
10
MICO 942-3L EPC INT AD / HSCH 3
3-way locking system Europrofile cylinder, within with automatic the HSCH 3 and lever deadlocking. handle
Europrofile cylinder (Key or thumb turn) and lever handle
A, B, C, D, E and F
11
MICO 942-3L EPC INT AD
3-way locking system None with automatic deadlocking.
Europrofile cylinder (Key or thumb turn)and lever handle
12
MICO 942-3 EPC INT MD / HSCH 3
3-way locking system Europrofile cylinder, within with manual deadlock. the HSCH 3 and lever handle
Europrofile cylinder (Key or thumb turn) and panic exit push plate
A, B, C, D, E and F
13
MICO 942-3 EPC INT MD
3-way locking system None with manual deadlock.
Europrofile cylinder (Key or thumb turn) and panic exit push plate
-
20 Nov 2011
Access control system (e.g. key pad or swipe card) not specified3 or key override via Europrofile cylinder within the HSCH3 cylinder guard and lever handle
-
-
333
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
334
14
MICO 942-3P EPC INT MD / HSCH 3
3-way locking system Europrofile cylinder, within with manual deadlock. the HSCH 3 and lever handle
Europrofile cylinder (Key or thumb turn) and push pad
A, B, C, D, E and F
15
MICO 942-3P EPC INT MD
3-way locking system None with manual deadlock.
Europrofile cylinder (Key or thumb turn) and push pad
-
16
MICO 942-3L EPC INT MD / HSCH 3
3-way locking system Europrofile cylinder, within with manual deadlock. the HSCH 3 and lever handle
Europrofile cylinder (Key or thumb turn) and lever handle
A, B, C, D, E and F
17
MICO 942-3L EPC INT MD
3-way locking system None with manual deadlock.
Europrofile cylinder (Key or thumb turn) and lever handle
-
18
MICO 942-3 3-way panic exit EPC SATE EM device with solenoid SEC / HSCH 3 deadlock and electromechanical access control powered by 12v.
19
MICO 942-3 EPC SATE EM SEC
3-way panic exit Access control system (e.g. Panic exit push plate device with solenoid key pad or swipe card) not deadlock and electro- specified3 and lever handle mechanical access control powered by 12v.
20
MICO 942-3P EPC SATE EM SEC / HSCH 3
3-way emergency exit device with solenoid deadlock and electromechanical access control powered by 12v.
21
MICO 942-3P EPC SATE EM SEC
3-way emergency exit Access control system (e.g. Push pad device with solenoid key pad or swipe card) not deadlock and electro- specified3 and lever handle mechanical access control powered by 12v.
22
MICO 942-3L 3-way emergency exit EPC SATE EM device with solenoid SEC / HSCH 3 deadlock and electromechanical access control powered by 12v.
23
MICO 942-3L 3-way emergency exit Access control system (e.g. Lever handle EPC SATE EM device with solenoid key pad or swipe card) not SEC deadlock and electro- specified3 and lever handle mechanical access control powered by 12v.
24
MICO 942-3 3-way panic exit Europrofile cylinder, within EPC SATE AD / device with automatic the HSCH 3 and lever HSCH 3 deadlock. handle
Access control system (e.g. Panic exit push plate key pad or swipe card) not specified3 or key override via Europrofile cylinder within the HSCH3 cylinder guard and lever handle
Access control system (e.g. Push pad key pad or swipe card) not specified3 or key override via Europrofile cylinder within the HSCH3 cylinder guard and lever handle
Access control system (e.g. Lever handle key pad or swipe card) not specified3 or key override via Europrofile cylinder within the HSCH3 cylinder guard and lever handle
Panic exit push plate
A, B, C, D, E and F
-
A, B, C, D, E and F
-
A, B, C, D, E and F
-
A, B, C, D, E and F
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 25
MICO 942-3P 3-way emergency exit Europrofile cylinder, within EPC SATE AD / device with automatic the HSCH 3 and lever HSCH 3 deadlock. handle
Push pad
A, B, C, D, E and F
26
3-way emergency exit Europrofile cylinder, within MICO 942-3L EPC SATE AD / device with automatic the HSCH 3 and lever HSCH 3 deadlock. handle
Lever handle
A, B, C, D, E and F
27
3-way panic exit MICO 942-3 EPC SATE MD / device with manual HSCH 3 deadlock.
Panic exit push plate
A, B, C, D, E and F
28
3-way emergency exit Europrofile cylinder, within MICO 942-3P EPC SATE MD / device with manual the HSCH 3 and lever HSCH 3 deadlock. handle
Push pad
A, B, C, D, E and F
29
3-way emergency exit Europrofile cylinder, within MICO 942-3L the HSCH 3 and lever EPC SATE MD / device with manual HSCH 3 deadlock. handle
Lever handle
A, B, C, D, E and F
30
MICO 942-3 / ELK 3 MICO 942-3P / ELK 3 MICO 942-3L / ELK 3 MICO 942-3 EM SEC / HSCH 3
31 32 33
3-way panic exit device 3-way emergency exit device 3-way emergency exit device 3-way locking system with solenoid deadlock and electromechanical access control powdered by 12v.
Europrofile cylinder, within the HSCH 3 and lever handle
Key via ELK 3
Panic exit push plate K, L,M,N, O, P, Q, R and T Key via ELK 3 Push pad K, L,M,N, O, P, Q, R and T Key via ELK 3 Lever handle K, L,M,N, O, P, Q, R and T G, H, I, J, K, L, M, N Access control system (e.g. Internal access and P key pad or swipe card) not control and thumb turn override via specified3 or key override Scandinavian oval via Scandinavian oval cylinder within the HSCH3 cylinder with push plate cylinder guard and lever handle
34
MICO 942-3 EM 3-way locking system Access control system (e.g. SEC with solenoid key pad or swipe card) not deadlock and specified3 and lever handle electromechanical access control powdered by 12v.
Access control and thumb turn override via Scandinavian oval cylinder with push plate
-
35
MICO 942-3P EM SEC / HSCH 3
3-way locking system with solenoid deadlock and electromechanical access control powdered by 12v.
Access control system (e.g. key pad or swipe card) not specified3 or key override via Scandinavian oval cylinder within the HSCH3 cylinder guard and lever handle
Access control and thumb turn override via Scandinavian oval cylinder with push pad
G, H, I, J, K, L, M, N and P
36
MICO 942-3P EM SEC
3-way locking system Access control system (e.g. key pad or swipe card) not with solenoid deadlock and specified3 and lever handle electromechanical access control powdered by 12v.
Access control and thumb turn override via Scandinavian oval cylinder with push pad
-
37
MICO 942-3L EM SEC / HSCH 3
3-way locking system with solenoid deadlock and electromechanical access control powdered by 12v.
Access control and G, H, I, J, K, L, M, N thumb turn override and P via Scandinavian oval cylinder with lever handle
20 Nov 2011
Access control system (e.g. key pad or swipe card) not specified3 or key override via Scandinavian oval cylinder within the HSCH3 cylinder guard and lever handle
335
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
336
3-way locking system Access control system (e.g. with solenoid key pad or swipe card) not deadlock and specified3 and lever handle electromechanical access control powdered by 12v.
Access control and thumb turn override via Scandinavian oval cylinder with lever handle
-
38
MICO 942-3L EM SEC
39
MICO 942-3L 3-way locking system Scandinavian oval cylinder, Scandinavian oval INT AD / HSCH with automatic within the HSCH 3 and cylinder (Key or 3 deadlocking. lever handle thumb turn) and lever handle
40
MICO 942-3L INT AD
41
MICO 942-3 INT 3-way locking system Scandinavian oval cylinder, Scandinavian oval G, H, I, J, K, L, M, N cylinder (Key or and P MD / HSCH 3 with manual deadlock. within the HSCH 3 and lever handle thumb turn) and panic exit push plate
42
MICO 942-3 INT 3-way locking system None MD with manual deadlock.
43
MICO 942-3P 3-way locking system Scandinavian oval cylinder, Scandinavian oval cylinder (Key or INT MD / HSCH with manual deadlock. within the HSCH 3 and lever handle thumb turn) and push 3 pad
44
MICO 942-3P INT MD
45
3-way locking system Scandinavian oval cylinder, Scandinavian oval MICO 942-3L cylinder (Key or INT MD / HSCH with manual deadlock. within the HSCH 3 and thumb turn) and lever 3 lever handle handle
46
MICO 942-3L INT MD
3-way locking system None with automatic deadlocking.
3-way locking system None with manual deadlock.
3-way locking system None with manual deadlock.
Scandinavian oval cylinder (Key or thumb turn)and lever handle
Scandinavian oval cylinder (Key or thumb turn) and panic exit push plate
Scandinavian oval cylinder (Key or thumb turn) and push pad
Scandinavian oval cylinder (Key or thumb turn) and lever handle
G, H, I, J, K, L, M, N and P
-
-
G, H, I, J, K, L, M, N and P
-
G, H, I, J, K, L, M, N and P
-
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Access control system (e.g. Panic exit push plate key pad or swipe card) not specified3 or key override via Scandinavian oval cylinder within the HSCH3 cylinder guard and lever handle
47
MICO 942-3 3-way panic exit SATE EM SEC / device with solenoid HSCH 3 deadlock and electromechanical access control powered by 12v.
48
Access control system (e.g. Panic exit push plate MICO 942-3 3-way panic exit SATE EM SEC device with solenoid key pad or swipe card) not deadlock and electro- specified3 and lever handle mechanical access control powered by 12v.
49
MICO 942-3P 3-way emergency exit SATE EM SEC / device with solenoid HSCH 3 deadlock and electromechanical access control powered by 12v.
50
MICO 942-3P SATE EM SEC
51
3-way emergency exit MICO 942-3L SATE EM SEC / device with solenoid deadlock and electroHSCH 3 mechanical access control powered by 12v.
52
MICO 942-3L SATE EM SEC
20 Nov 2011
Access control system (e.g. Push pad key pad or swipe card) not specified3 or key override via Scandinavian oval cylinder within the HSCH3 cylinder guard and lever handle
3-way emergency exit Access control system (e.g. Push pad device with solenoid key pad or swipe card) not deadlock and electro- specified3 and lever handle mechanical access control powered by 12v. Access control system (e.g. Lever handle key pad or swipe card) not specified3 or key override via Scandinavian oval cylinder within the HSCH3 cylinder guard and lever handle
3-way emergency exit Access control system (e.g. Lever handle device with solenoid key pad or swipe card) not deadlock and electro- specified3 and lever handle mechanical access control powered by 12v.
G, H, I, J, K, L, M, N and P
-
G, H, I, J, K, L, M, N and P
-
G, H, I, J, K, L, M, N and P
-
337
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 53
MICO 942-3 SATE AD / HSCH 3
3-way panic exit Scandinavian oval cylinder, Panic exit push plate device with automatic within the HSCH 3 and deadlock. lever handle
G, H, I, J, K, L, M, N and P
54
MICO 942-3P SATE AD / HSCH 3
3-way emergency exit Scandinavian oval cylinder, Push pad device with automatic within the HSCH 3 and deadlock. lever handle
G, H, I, J, K, L, M, N and P
55
MICO 942-3L SATE AD / HSCH 3
3-way emergency exit Scandinavian oval cylinder, Lever handle device with automatic within the HSCH 3 and deadlock. lever handle
G, H, I, J, K, L, M, N and P
56
MICO 942-3 SATE MD / HSCH 3
3-way panic exit device with manual deadlock.
57
MICO 942-3P SATE MD / HSCH 3
3-way emergency exit Scandinavian oval cylinder, Push pad device with manual within the HSCH 3 and lever handle deadlock.
G, H, I, J, K, L, M, N and P
58
MICO 942-3L SATE MD / HSCH 3
3-way emergency exit Scandinavian oval cylinder, Lever handle device with manual within the HSCH 3 and deadlock. lever handle
G, H, I, J, K, L, M, N and P
59
MICO 942-3L EPC INT AD / HSCH 4
3-way locking system Europrofile cylinder within with automatic the HSCH 4 and lever deadlocking. handle
Europrofile cylinder (Key or thumb turn) and lever handle
A, B, C, D, E and F
60
MICO 942-3 EPC INT MD / HSCH 4
3-way locking system Europrofile cylinder within with manual deadlock. the HSCH 4 and lever handle
Europrofile cylinder (Key or thumb turn) and panic exit push plate
A, B, C, D, E and F
61
MICO 942-3P EPC INT MD / HSCH 4
3-way locking system Europrofile cylinder within with manual deadlock. the HSCH 4 and lever handle
Europrofile cylinder (Key or thumb turn) and push pad
A, B, C, D, E and F
62
MICO 942-3L EPC INT MD / HSCH 4
3-way locking system Europrofile cylinder within with manual deadlock. the HSCH 4 and lever handle
Europrofile cylinder (Key or thumb turn) and lever handle
A, B, C, D, E and F
63
3-way locking system Scandinavian oval cylinder Scandinavian oval MICO 942-3L cylinder (Key or within the HSCH 4 and INT AD / HSCH with automatic thumb turn) and lever lever handle deadlocking. 4 handle
64
G, H, I, J, K, L, M, N MICO 942-3 INT 3-way locking system Scandinavian oval cylinder Scandinavian oval and P cylinder (Key or MD / HSCH 4 with manual deadlock. within the HSCH 4 and lever handle thumb turn) and panic exit push plate
65
3-way locking system Scandinavian oval cylinder Scandinavian oval MICO 942-3P cylinder (Key or INT MD / HSCH with manual deadlock. within the HSCH 4 and thumb turn) and push 4 lever handle pad
G, H, I, J, K, L, M, N and P
66
MICO 942-3L 3-way locking system Scandinavian oval cylinder Scandinavian oval INT MD / HSCH with manual deadlock. within the HSCH 4 and cylinder (Key or 4 lever handle thumb turn) and lever handle
G, H, I, J, K, L, M, N and P
67
M0455
Surface mounted barrel bolts
Scandinavian oval cylinder, Panic exit push plate within the HSCH 3 and lever handle
-
-
G, H, I, J, K, L, M, N and P
G, H, I, J, K, L, M, N and P
-
Compatible Cylinders
338
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Cylinder Reference
Manufacturer
Model
Type
A
Abloy
Protec CY304
Double Europrofile cylinder (Key:Key or Key:Thumbturn)
B
Abloy
Disclock Pro CY304
Double Europrofile cylinder (Key:Key or Key:Thumbturn)
C
ASSA
Twin 7622
Double Europrofile cylinder (Key:Key or Key:Thumbturn)
D
ASSA
C5822
Double Europrofile cylinder (Key:Key or Key:Thumbturn)
E
ASSA
4822
Double Europrofile cylinder (Key:Key or Key:Thumbturn)
F
Kaba
Quattro S Euro
Double Europrofile cylinder (Key:Key or Key:Thumbturn)
G
ASSA
4807
Half Scandinavian oval mechanical cylinder
H
ASSA
Twin 7607
Half Scandinavian oval mechanical cylinder
I
ASSA
C5807
Half Scandinavian oval mechanical cylinder
J
ASSA
4407
Half Scandinavian oval mechanical cylinder
K
Abloy
Protec CY201PT
Half Scandinavian oval mechanical cylinder
L
Locken
CL-PL2WR
Half Scandinavian oval mechatronic cylinder
M
Kaba
Quattro S Oval
Half Scandinavian oval mechanical cylinder
N
Kaba
K20 Oval
Half Scandinavian oval mechanical cylinder
O
Abloy
Disclock Pro CY201DPHalf Scandinavian oval mechanical cylinder
P
ASSA
4801
Half Scandinavian oval mechanical cylinder
Q
ASSA
Twin 7601
Half Scandinavian oval mechanical cylinder
R
ASSA
C5801
Half Scandinavian oval mechanical cylinder
T
ASSA
4401
Half Scandinavian oval mechanical cylinder
Notes: 1. This security rating prevails when the doorsets are locked in the optimum locked condition. The following locking configurations incorporate a manual deadlock mechanism: 13, 15, 17, 42, 44 and 46. If the door is closed and the deadlock mechanism is not engaged then a minimum locked condition exists. In this condition the doorsets achieve a minimum of a Security Rating 1. 2. The scope of this approval covers double leaf doorsets with equal leafs. Double doorsets with unequal leafs are not covered by this approval. 3. The resistance of the access control locks to “non-mechanical” attack is not covered by this approval as they were outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that specifiers’ satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 4. Although outside the scope of LPS 1175: Issue 6, special consideration should be paid to the use of locking systems with separate deadlocks, e.g. Mico 942-3 INT MD. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or exit device. Furthermore, double doorsets with panic devices fitted to only one leaf do not necessarily suit public areas. For further information, please refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively.
PSF Wales Limited Llys Rhiannon, Cil Yr Ychen Industrial Estate, Landeilo Road, Llandybie, Ammanford, Carmarthenshire SA18 3GY, United Kingdom Tel: +44 (0)1269 851777 • Fax: +44 (0)1269 851747 E-mail: [email protected] • Website: www.psfwales.co.uk Certificate No: 953a to LPS 1175: Issue 6
Hinged Security Doorsets Product Name Hercules SAF 3 Hercules SAF 4
Type Single leaf outward opening hinged doorset Double leaf outward opening hinged doorset Single leaf outward opening hinged doorset Double leaf outward opening hinged doorset
20 Nov 2011
Structural Opening Height (m) 2.12
Structural Opening Width (m) 1.12
Security Rating 3
Cert. No. 953a/01
2.21
2.21
31
953a/02
2.12
1.12
4
953a/03
2.21
1
953a/04
2.21
4
339
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Approved Locking Configurations
LPCB Ref. No.
Product Name
Type
Compatible Locking Systems
953a/01
Hercules SAF 3
953a/02
Hercules SAF 3
953a/03
Hercules SAF 4
953a/04
Hercules SAF 4
Single leaf outw ard opening hinged doorset Double leaf outw ard opening hinged doorset Single leaf outw ard opening hinged doorset Double leaf outw ard opening hinged doorset
Active Leaf
Passive Leaf
1 and 2
N/A
1 and 2
3
1 and 2
N/A
1 and 2
3
Compatible Locking Systems
Com patible Locking System 1
Manufacturer
2
Tindall Engineering
3
Commercial Body Fittings Limited
Tindall Engineering
Model / Type
External Face
Internal Face
Mico 942-3L INT AD / USCH4 USCH4 cylinder Thumbturn and lever three-point auto-deadlocking guard incorporating a handle auto-bolting system w ith Scandinavian oval external cylinder access cylinder USCH4 cylinder Thumbturn and lever Mico 942-3L INT MD / USCH4 three-point manual-deadlocking guard incorporating a handle auto-bolting system w ith Scandinavian oval external cylinder access cylinder Sprung tow er bolt
-
Tw o sprung tow er bolts
Compatible Cylinders A to G
A to G
N/A
Compatible Cylinders
Cylinder Reference A
Manufacturer
Model
Type
Abloy
Disclock Pro CY201DP
Mechanical Scandinavian oval cylinder
B
Assa
4807
Mechanical Scandinavian oval cylinder
C
Assa
C5807
Mechanical Scandinavian oval cylinder
D
Assa
Tw in 7607
Mechanical Scandinavian oval cylinder
E
Kaba
K20 Oval
Mechanical Scandinavian oval cylinder
F
Kaba
Quattro S Oval
Mechanical Scandinavian oval cylinder
G
Locken
CL-PL2WR
Mechatronic Scandinavian oval cylinder2
Notes: 1. This rating is achieved with both bolts engaged on the passive leaf engaged and the lock mechanism fitted to the primary leaf engaged and deadlocked. The doorset achieves at least Security Rating 1 if one of the bolts on the passive leaf is not engaged. 2. The resistance of the electronic cylinder to “non-mechanical” attack has not been assessed as it is outside the scope of LPS1175. Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of the keys that may be used to operate the cylinder. It is therefore recommended that specifiers and installers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse and are resistant to any environmental conditions/interference that may cause the lock to disengage.
R & D Sheetmetal Limited Unit 1A, Victoria Court, Colliers Way, Clayton West, Huddersfield, West Yorkshire HD8 9TR, United Kingdom Tel: +44 (0)1484 864886 • Fax: +44 (0)1484 866505 E-mail: [email protected] • Website: www.randdsheetmetal.co.uk Certificate No: 1034b to LPS 1175: Issue 7
340
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Hinged Security Doorset Product Name Security Evo IV Security Evo V Security Evo VI
Product Type Single leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset
Minimum Height (m) 1.8
Maximum Height (m) 2.3
Minimum Width (m) 0.8
Maximum Width (m) 1.1
Security Rating 4
Cert. No.
1.8
2.3
0.8
1.1
5
1034b/02
1.8
2.3
0.8
1.1
6
1034b/03
1034b/01
Compatible Locking Configurations
Product Name Doorset Configuration
Com patible Locking System s
Security Evo IV Single leaf outw ard opening hinged security doorset
1 to 15
Security Evo V
Single leaf outw ard opening hinged security doorset
16 to 30
Security Evo VI Single leaf outw ard opening hinged security doorset
31 to 45
Compatible Locking Systems
Com patible Manufacturer Locking System 1
2
Tindall Engineering Limited Tindall Engineering Limited
3
Tindall Engineering Limited
4
Tindall Engineering Limited
5
Tindall Engineering Limited
20 Nov 2011
Model
Type
Compatible Operating Devices External Internal Face Face Abryll AD3 Single point locking Key and Thumb turn /USCH 4 system w ith automatic lever handle and lever deadlocking handle Abryll MD2 Single point locking Key and Key or /USCH 4 system w ith manual lever handle thumb turn deadlocking and push plate Abryll MD1 Single point locking Key and Key or /USCH 4 system w ith manual lever handle thumb turn deadlocking and push pad Abryll MD3 Single point locking Key and Key or /USCH 4 system w ith manual lever handle thumb turn and lever deadlocking handle Single point locking Key and Key or Abryll EPC MD2 /USCH 4 system w ith manual lever handle thumb turn deadlocking and push plate
Compatible Cylinders
A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK
341
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 6
Tindall Engineering Limited
Abryll EPC MD1 /USCH 4
Single point locking system w ith manual deadlocking
7
Tindall Engineering Limited
Abryll EPC MD3 /USCH 4
Single point locking system w ith manual deadlocking
8
Tindall Engineering Limited Tindall Engineering Limited
Mico EVO 3 AD3 /USCH 4
10
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD1 /USCH 4 w ith manual deadlocking
11
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD3 /USCH 4 w ith manual deadlocking
12
Tindall Engineering Limited
Mico EVO 3 AD3 EPC /USCH 4
13
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD2 EPC w ith manual deadlocking /USCH 4
14
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD1 w ith manual deadlocking EPC/USCH 4
15
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system w ith manual deadlocking MD3 EPC/USCH 4
16
Tindall Engineering Limited Tindall Engineering Limited
9
17
342
3-w ay locking system w ith automatic deadlocking Mico EVO 3 3-w ay locking system MD2 /USCH 4 w ith manual deadlocking
Abryll AD3 /USCH 5 Abryll MD2 /USCH 5
3-w ay locking system w ith automatic deadlocking
Single point locking system w ith automatic deadlocking Single point locking system w ith manual deadlocking
18
Tindall Engineering Limited
Abryll MD1 /USCH 5
Single point locking system w ith manual deadlocking
19
Tindall Engineering Limited
Abryll MD3 /USCH 5
Single point locking system w ith manual deadlocking
20
Tindall Engineering Limited
Abryll EPC MD2 /USCH 5
Single point locking system w ith manual deadlocking
Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Thumb turn lever handle and lever handle Key and Key or lever handle thumb turn and push plate Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Key or lever handle thumb turn and lever handle Key and Key or lever handle thumb turn and push plate Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Thumb turn lever handle and lever handle Key and Key or lever handle thumb turn and push plate Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Key or lever handle thumb turn and push plate
R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 21
Tindall Engineering Limited
Abryll EPC MD1 /USCH 5
Single point locking system w ith manual deadlocking
22
Tindall Engineering Limited
Abryll EPC MD3 /USCH 5
Single point locking system w ith manual deadlocking
23
Tindall Engineering Limited Tindall Engineering Limited
Mico EVO 3 AD3 /USCH 5
25
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD1 /USCH 5 w ith manual deadlocking
26
Tindall Engineering Limited
3-w ay locking system Mico EVO MD3 /USCH 5 w ith manual deadlocking
27
Tindall Engineering Limited
Mico EVO 3 AD3 EPC /USCH 5
3-w ay locking system w ith automatic deadlocking
28
Tindall Engineering Limited
Mico EVO3 MD2 EPC /USCH 5
3-w ay locking system w ith manual deadlocking
29
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD1 EPC w ith manual deadlocking /USCH 5
30
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD3 EPC w ith manual deadlocking /USCH 5
31
Tindall Engineering Limited Tindall Engineering Limited
Abryll AD3 /USCH 6
24
32
3-w ay locking system w ith automatic deadlocking Mico EVO 3 3-w ay locking system MD2 /USCH 5 w ith manual deadlocking
Abryll MD2 /USCH 6
Single point locking system w ith automatic deadlocking Single point locking system w ith manual deadlocking
33
Tindall Engineering Limited
Abryll MD1 /USCH 6
Single point locking system w ith manual deadlocking
34
Tindall Engineering Limited
Abryll MD3 /USCH 6
Single point locking system w ith manual deadlocking
35
Tindall Engineering Limited
Abryll EPC MD2 /USCH 6
Single point locking system w ith manual deadlocking
20 Nov 2011
Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Thumb turn lever handle and lever handle Key and Key or lever handle thumb turn and push plate Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Key or lever handle thumb turn and lever handle Key and Key or lever handle thumb turn and push plate Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Thumb turn lever handle and lever handle Key and Key or lever handle thumb turn and push plate Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Key or lever handle thumb turn and push plate
R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK
343
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 36
Tindall Engineering Limited
Abryll EPC MD1 /USCH 6
Single point locking system w ith manual deadlocking
37
Tindall Engineering Limited
Abryll EPC MD3 /USCH 6
Single point locking system w ith manual deadlocking
38
Tindall Engineering Limited Tindall Engineering Limited
Mico EVO 3 AD3 /USCH 6
40
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD1 /USCH 6 w ith manual deadlocking
41
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD3 /USCH 6 w ith manual deadlocking
42
Tindall Engineering Limited
Mico EVO 3 AD3 EPC /USCH 6
43
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD2 EPC w ith manual deadlocking /USCH 6
44
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD1 EPC w ith manual deadlocking /USCH 6
45
Tindall Engineering Limited
Mico EVO 3 3-w ay locking system MD3 EPC w ith manual deadlocking /USCH 6
39
3-w ay locking system w ith automatic deadlocking Mico EVO 3 3-w ay locking system MD2 /USCH 6 w ith manual deadlocking
3-w ay locking system w ith automatic deadlocking
Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Thumb turn lever handle and lever handle Key and Key or lever handle thumb turn and push plate Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle Key and Key or lever handle thumb turn and lever handle Key and Key or lever handle thumb turn and push plate Key and Key or lever handle thumb turn and push pad Key and Key or lever handle thumb turn and lever handle
R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, Al, AM, AN, AO, AP, AQ and AR R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK R, S, T, U, V, W, X, Y, Z, AA, AB, AC, AD, AE, AF, AG, AH, AI and AK
Compatible Cylinders
Cylinder Reference A
Manufacturer
Model
Type
Abloy
Protec CY201 PT
Scandinavian Oval
B
Abloy
Protec Cliq CY201
Scandinavian Oval
C
AMS
CL-OVLD
Scandinavian Oval
D
ASSA
4401dp
Scandinavian Oval
E
ASSA
4401 Cliq
Scandinavian Oval
344
F
ASSA
4407dp
Scandinavian Oval
G
ASSA
4407 Cliq
Scandinavian Oval
H
ASSA
4801
Scandinavian Oval
I
ASSA
4807
Scandinavian Oval
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES J
ASSA
C5801
Scandinavian Oval
K
ASSA
C5807
Scandinavian Oval
L
ASSA
Tw in 7601
Scandinavian Oval
M
ASSA
Tw in 7607
Scandinavian Oval
N
Kaba
K20
Scandinavian Oval
O
Kaba
Quattro PluS
Scandinavian Oval
P
Locken
CL-PL2WR
Scandinavian Oval
Q
Medeco
M3-ARX
Scandinavian Oval
R
Abloy
Protec CY304
Europrofile double cylinder (key:key)
S
Abloy
Protec Cliq CY333
Europrofile double cylinder (key:thumbturn)
T
Abloy
Protec CY333
Europrofile double cylinder (key:thumbturn)
U
Abloy
Protec Cliq CY304
Europrofile double cylinder (key:key)
V
Abloy
Protec CY305
Europrofile double cylinder (key:thumbturn)
W
Abloy
Protec Cliq CY305
Europrofile double cylinder (key:thumbturn)
X
ASSA
4422dp
Europrofile double cylinder (key:key)
Y
ASSA
4427dp
Europrofile double cylinder (key:thumbturn)
Z
ASSA
44M22 Cliq
Europrofile double cylinder (key:key)
AA
ASSA
44M27 Cliq
Europrofile double cylinder (key:thumbturn)
AB
ASSA
4822
Europrofile double cylinder (key:key)
AC
ASSA
4827
Europrofile double cylinder (key:thumbturn)
AD
ASSA
C5822
Europrofile double cylinder (key:key)
AE
ASSA
C5827
Europrofile double cylinder (key:thumbturn)
AF
ASSA
7622
Europrofile double cylinder (key:key)
AG
ASSA
7627
Europrofile double cylinder (key:thumbturn)
AH
Kaba
Quattro PluS
Europrofile double cylinder (key:key)
AI
Kaba
Quattro PluS
Europrofile double cylinder (key:thumbturn)
AJ
Medeco
M3-ARX
Europrofile double cylinder (key:key)
AK
Medeco
M3-ARX
Europrofile double cylinder (key:thumbturn)
AL
Abloy
Protec CY403
Rim
AM
Abloy
Protec Cliq CY403
Rim
AN
Kaba
Quatro Plus
Rim
AO
Medeco
M3-ARX
Rim
AP
AMS
CL-CA2D
Finish Round
AQ
ASSA
4857
Round threaded
AR
ASSA
C5857
Round threaded
Notes: 1. Certification does not cover the use of locks other than those listed above. Utilisation of unlisted locks may affect the level of security offered by the doorset. 2. The doorset’s resistance relies on the supporting substrate offering compatible resistance to manual attack. 3. The Security Evo IV doorset is approved when installed in accordance with the instructions detailed on document EVO-INST-02 (Issue 1). 4. The Security Evo V and VI doorsets are approved when installed in accordance with the instructions detailed on document EVOINST-01 (Issue 3) into the Security Evo enclosures only.
20 Nov 2011
345
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
Safe Partnership 3 East Street, Wareham, Dorset BH20 4NN, United Kingdom Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300 E-mail: [email protected] • Website: www.safepartnership.co.uk Certificate No: 835a to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Type
Safe Doorset SR1
Single leaf outward opening hinged security timber doorset Single leaf outward opening hinged security timber doorset
Safe Doorset SR2
Minimum Clear Opening Height (m) 1.8
Maximum Clear Opening Height (m) 2
Minimum Clear Opening Width (m) 0.675
Maximum Clear Opening Width (m) 0.825
Security Rating
Cert. No.
2
835a/01
1.8
2
0.675
0.825
21
835a/02
Compatible Locking Devices
Lock Position
Lockset
Upper
ERA mortice deadlock (Product code 325-31)
Middle
Low er
Cylinder
ERA Satin 35/35 mm key/thumbturn europrofile double cylinder (Product code 4103-51) ERA Euro Pro Fit ERA Satin 35/35 mm sashlock (Product code key/thumbturn europrofile 326-31) double cylinder (Product code 4103-51) ERA Fortress 5 lever mortice sashlock (Product code 362-31) ERA mortice deadlock ERA Satin 35/35 mm (Product code 325-31) key/thumbturn europrofile double cylinder (Product code 4103-51)
Associated Ironm ongery Solon Satin Escutcheons (Product code 263 55 ESC) Solon Satin sash lever handle fitted to each face (Product code BD0406) Solon Satin sash lever handle fitted to each face (Product code 222-00) Solon Satin Escutcheons (Product code 263 55 ESC)
Doorset SR1
SR2
Note: 1. This doorset achieves it’s Security Rating when all three locks are engaged. The doorset achieves Security Rating 1 when only one lock is engaged.
SafeGuard Doors, A Division of Adams Rite Europe Limited School Street, Willenhall, West Midlands WV13 3PW, United Kingdom Tel: +44 (0))1902 364601 • Fax: +44 (0)1902 364602 E-mail: [email protected] • Website: www.safeguarddoors.co.uk Certificate No: 661a to LPS 1175: Issue 5
346
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Hinged Security Doorsets Product Name
Type
Trenchard
Single leaf, outward opening hinged security doorset Single leaf, outward opening hinged security doorset
Fenwick
Minimum Clear Opening Height (m) 1.8
Maximum Clear Opening Height (m) 2.4
Minimum Clear Opening Width (m) 0.76
Maximum Clear Opening Width (m) 1.2
Security Rating
Cert. No.
3
661a/01
1.8
2.4
0.76
1.2
4
661a/02
Compatible Locking Systems
LPCB Ref. No.
Trade Nam e
Com patible Locking System s Manufacturer
Model
661a/01
Trenchard
Surelock McGill
EX210(B1) -L1
661a/02
Fenw ick
Surelock McGill
EX210(B1)
Type
Compatible Cylinders
Three point surface mounted locking system fitted w ith push bar and LEO external operating device Three point surface mounted locking system fitted w ith push bar
Bramah C17SI DOM 419ix10G Kaba KV207.0000C5-SC Union 26X11B Yale PK1133 Pro-Key N/A
Stafford Bridge Doors Limited Bedford Road, Pavenham, Bedford MK43 7PS, United Kingdom Tel: +44 (0)1234 826316 • Fax: +44 (0)1234 826319 E-mail: [email protected] • Website: www.surelockmcgillgroup.com/sbd Certificate No: 516a to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
Sandhurst
Single leaf, outward and inward opening hinged security doorset Single leaf, outward opening hinged security doorset Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset
Wilton Halton Sandhurst Wilton Halton
Minimum Structural Opening Height (m) 1.9
Maximum Structural Opening Height (m) 2.5
Minimum Structural Opening Width (m) 0.7
Maximum Structural Opening Width (m) 1.4
Security Rating
Cert. No.
3
516a/01
1.9
2.5
0.7
1.4
4
516a/03
1.468
2.5
0.7
1.4
4
516a/04
1.9
2.5
1.4
3.0
3
516a/05
1.9
2.5
1.4
3.0
4
516a/06
1.9
2.5
1.4
3.0
4
516a/07
Compatible Locking Systems
20 Nov 2011
347
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES LPCB Ref. No.
516a/01
Trade Name
Sandhurst
Type
Single leaf outw ard opening doorset
Nom inal Compatible Locking Systems Leaf Thickness Active Leaf Passive Leaf (mm ) 46 AA, AB, AC, AD1, AE, AF1, AG, N/A AH, AI, AJ, AK1, AL, AM1, AN1, AN3, AO, AP, AQ1, AR1 and AU 54
Single leaf inw ard opening doorset
46
54
516a/03
Wilton
516a/04
Halton
516a/05
Sandhurst
Single leaf outw ard opening doorset Single leaf outw ard opening doorset Double leaf outw ard opening doorset
55 55 46
AA, AB, AC, AD, AD1, AE, AF, AF1, AG, AH, AI, AJ, AK, AL, AM, AN1, AN2, AO, AP, AQ, AR and AU AA, AB, AC, AD1, AE, AF1, AI, AJ, AK1, AL, AM1, AO, AP, AQ1 and AR1 AA, AB, AC, AD, AD1, AE, AF, AF1, AI, AJ, AK, AL, AM, AO, AP, AQ and AR AC1, AJ1, AK2, AL, AM2, AN, AP1, AQ2, AR2 and AS AC1, AJ1, AK2, AL, AM2, AN, AP1, AQ2, AR2 and AS AD1, AE, AF1, AK1, AL, AM1, AN1, AN3, AQ1 and AR1
54
AD, AE, AF, AK, AL, AM, AN1, AN2, AQ and AR
516a/06
Wilton
Double leaf outw ard opening doorset
55
AK2, AL , AM2, AN, AQ2, AR2 and AS
516a/07
Halton
Double leaf outw ard opening doorset
55
AK2, AL , AM2, AN, AQ2, AR2 and AS
N/A
N/A
N/A
N/A N/A AT or tw o-point bolting version of locking system on the active leaf AT or tw o-point bolting version of locking system on the active leaf AT or tw o-point bolting version of locking system on the active leaf AT or tw o-point bolting version of locking system on the active leaf
Compatible Locks
348
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Com patible Manufacturer Locking System AA Surelock McGill
Trimlock (D117)
Three point mortice locking system
AB
Surelock McGill
EX110-L1
AC
Surelock McGill
EX210-L1
AC1
Surelock McGill
EX210-L2
AD
Surelock McGill
DL200-P
AD1
Surelock McGill
DL200-K15P
AD2
Surelock McGill
DL200-K15P5
Three point surface mounted emergency exit system fitted w ith lever handle or push pad and LEO module Three point surface mounted panic exit system fitted w ith push bar and LEO module Three point surface mounted panic exit system fitted w ith push bar and 'SR4' LEO module Three point surface mounted locking system w ith automatic cylinder deadlock operated by key (outside) and turn-knob (inside) Three point surface mounted locking system w ith automatic cylinder deadlock operated by key (outside) and turn-knob (inside) w ith integrated turn-knob protection shroud Three point surface mounted locking system w ith automatic cylinder deadlock operated by key (outside) and turn-knob (inside) w ith integrated turn-knob protection shroud
AE
Surelock McGill
DL100
AF
Surelock McGill
DL106-P
AF1
Surelock McGill
DL106-K15P
20 Nov 2011
Model
Type
Three point surface mounted locking system w ith lever-key operated deadlock Three point surface mounted locking system w ith cylinder deadlock operated by key (outside) and turnknob (inside) Three point surface mounted locking system w ith cylinder deadlock operated by key (outside) and turnknob (inside) w ith integrated turnknob protection shroud
Com patible Cylinders
4, 51, 7, 81, 14, 151, 19, 201, 24, 251, 27, 281, 35, 361, 39, 401, 43, 441, 49, 501, 54 and 551 22, 29, 33, 46, 51 and 52
22, 29, 33, 46, 51 and 52
22, 29, 33, 46, 51 and 52
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
N/A
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
349
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES AF2
Surelock McGill
DL106-K15P5
AG
Surelock McGill
2, 3, 6, 10, 12, 13, 17, 18, 21, 23, 26, 30, 31, 34, 38, 41, 42, 45, 47, 48, 53, 56, 57 and 58
AH
Surelock McGill
AI
Surelock McGill
Single point surface mounted locking Stirling DL800 w ith K2 and K13P device w ith cylinder deadlock options operated by key (outside) and turnknob (inside) Stirling EX800 Single point surface mounted w ith K2 and K13P emergency exit device fitted w ith options external key access A1-L1 Three point surface mounted locking system fitted w ith lever handle or push pad and LEO module
AJ
Surelock McGill
B1-L1
22, 29, 33, 46, 51 and 52
AJ1
Surelock McGill
B1-L2
AK
Surelock McGill
C1-P
AK1
Surelock McGill
C1-K15P
AK2
Surelock McGill
C1-K15P5
AL
Surelock McGill
D1
350
Three point surface mounted locking 2, 10, 12, 17, 21, 30, 31, 41, 42, 48, system w ith cylinder deadlock 56, 57 and 58 operated by key (outside) and turnknob (inside) w ith integrated turnknob protection shroud
Three point surface mounted panic exit system fitted w ith push bar and LEO module Three point surface mounted panic exit system fitted w ith push bar and 'SR4' LEO module Three point surface mounted locking system w ith automatic cylinder deadlock operated by key (outside) and turn-knob (inside) Three point surface mounted locking system w ith automatic cylinder deadlock operated by key (outside) and turn-knob (inside) w ith integrated turn-knob protection shroud
2, 3, 6, 10, 12, 13, 17, 18, 21, 23, 26, 30, 31, 34, 38, 41, 42, 45, 47, 48, 53, 56, 57 and 58 22, 29, 33, 46, 51 and 52
1, 9, 11, 16, 22, 29, 32, 37, 46, 51 and 52 2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
2, 10, 12, 17, 21, 30, 31, 41, 42, 48 , 56, 57 and 58
Three point surface mounted locking 2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58 system w ith automatic cylinder deadlock operated by key (outside) and turn-knob (inside) w ith integrated turn-knob protection shroud Three point surface mounted locking N/A system w ith lever-key operated deadlock
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES AM
Surelock McGill
D6-P
Three point surface mounted locking system w ith cylinder deadlock operated by key (outside) and turnknob (inside) Three point surface mounted locking system w ith cylinder deadlock operated by key (outside) and turnknob (inside) w ith integrated turnknob protection shroud Three point surface mounted locking system w ith cylinder deadlock operated by key (outside) and turnknob (inside) w ith integrated turnknob protection shroud
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
AM1
Surelock McGill
D6-K15P
AM2
Surelock McGill
D6-K15P5
AN
Surelock McGill
25C1-P5R#2,3X
25mm throw three point locking system w ith solenoid2 deadlock (pow er to release) and external cylinder operation
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
AN1
Surelock McGill
25C1-PR#2,3X
25mm throw three point locking system w ith solenoid2 deadlock (pow er to release) and external cylinder operation
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
AN2
Surelock McGill
25C1-PR#2,3
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
AN3
Surelock McGill
25C1-K15 PR#2,3
AO
Surelock McGill
Slimline 315R-L1 or 315L-L1
AP
Surelock McGill
Slimline 314R-L1 or 314L-L1
AP1
Surelock McGill
Slimline 314R-L2 or 314L-L2
AQ
Surelock McGill
Slimline 313-KP
25mm throw three point locking system w ith solenoid2 deadlock (pow er to release) and external cylinder operation 25mm throw three point locking system w ith solenoid2 deadlock (pow er to release) external cylinder operation Three point surface mounted emergency exit system fitted w ith lever handle or push pad and LEO module5 Three point surface mounted panic exit system fitted w ith push bar and LEO module6 Three point surface mounted panic exit system fitted w ith push bar and 'SR4' LEO module6 Three point surface mounted locking system w ith automatic cylinder deadlock operated by key (outside) and turn-knob (inside)
20 Nov 2011
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
22, 29, 33, 46, 51 and 52
22, 29, 33, 46, 51 and 52
1, 9, 11, 16, 22, 29, 32, 37, 46, 51 and 52 2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
351
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES AQ1
Surelock McGill
Slimline 313KK15P
Three point surface mounted locking 2, 10, 12, 17, 21, 30, 31, 41, 42, 48, system w ith automatic cylinder 56, 57 and 58 deadlock operated by key (outside) and turn-knob (inside) w ith integrated turn-knob protection shroud
AQ2
Surelock McGill
Slimline 313KK15P5
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
AR
Surelock McGill
AR1
Surelock McGill
AR2
Surelock McGill
Slimline 313A0K15P5
Three point surface mounted locking 2, 10, 12, 17, 21, 30, 31, 41, 42, 48, system w ith cylinder deadlock 56, 57 and 58 operated by key (outside) and turnknob (inside) w ith integrated turnknob protection shroud
AS
Surelock McGill
Slimline 325RK2P5 R#2,3 or 325L-K2P5 R#2,3
AT
Surelock McGill
S3TB-W
25mm throw three point locking system w ith solenoid2 deadlock (pow er to release) and external cylinder operation Barrel bolt (2 off)
AU
Surelock McGill
Single point surface mounted Stirling AC800 w ith K2 and K13P solenoid2 (pow er to release) fitted options w ith external key access
Three point surface mounted locking system w ith automatic cylinder deadlock operated by key (outside) and turn-knob (inside) w ith integrated turn-knob protection shroud Slimline 313-A0P Three point surface mounted locking system w ith cylinder deadlock operated by key (outside)and turnknob (inside) Slimline 313Three point surface mounted locking A0K15P system w ith cylinder deadlock operated by key (outside) and turnknob (inside) w ith integrated turnknob protection shroud
2
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
2, 10, 12, 17, 21, 30, 31, 41, 42, 48, 56, 57 and 58
N/A 2, 3, 6, 10, 12, 13, 17, 18, 21, 23, 26, 30, 31, 34, 38, 41, 42, 45, 47, 48, 53, 56, 57 and 58
Compatible Cylinders
Com patible Cylinder
Manufacturer
Model
Type
1
Abloy
Disklock Pro CY404 DP
Screw -in single cylinder
2
Abloy
Disklock Pro CY405 DP
Rim cylinder
3
Abloy
Disklock Pro CY303 DP
Single Europrofile cylinder
4
Abloy
Disklock Pro CY304 DP
Double Europrofile cylinder (key:key)
5
Abloy
Disklock Pro CY305 DP
Double Europrofile cylinder (key:thumbturn)1
6
Assa
4823
Single Europrofile cylinder
7
Assa
4822
Double Europrofile cylinder (key:key)
8
Assa
4824
Double Europrofile cylinder (key:thumbturn)1
9
Assa
4851
Screw -in single cylinder
10
Assa
4857
Rim cylinder
352
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 11
Assa
C5851
Screw -in single cylinder
12
Assa
C5857
Rim cylinder
13
Assa
Ruko Flexcore - F523
Single Europrofile cylinder
14
Assa
Ruko Flexcore - F522
Double Europrofile cylinder (key:key)
15
Assa
Ruko Flexcore - F524
Double Europrofile cylinder (key:thumbturn)1
16
Assa
F551
Screw -in single cylinder
17
Assa
Ruko Flexcore - F557
Rim cylinder
18
Assa
Tw in Combi - C5823
Single Europrofile cylinder
19
Assa
Tw in Combi - C5822
Double Europrofile cylinder (key:key)
20
Assa
Tw in Combi - C5821
Double Europrofile cylinder (key:thumbturn)1
21
Bramah
C17
Rim cylinder
22
Bramah
C17SI
Screw -in single cylinder
23
Chubb
TXE3010
Single Europrofile cylinder
24
Chubb
TXED3030
Double Europrofile cylinder (key:key)
25
Chubb
TXET3030
Double Europrofile cylinder (key:thumbturn)1
26
Dom
333 H RS5
Single Europrofile cylinder
27
Dom
333 RS5
Double Europrofile cylinder (key:key)
28
Dom
333 K RS5
Double Europrofile cylinder (key:thumbturn)1
29
Dom
419ix10KG
Screw -in single cylinder
30
Dom
555ix10G
Rim cylinder
31
Kaba
KV06.100
Rim cylinder
32
Kaba
K207.203 C5-SC
Screw -in single cylinder
33
Kaba
K2070000C5-SC
Armoured screw -in single cylinder
34
Kaba
QS 152.100.00
Single Europrofile cylinder
35
Kaba
QS 150.100.00
Double Europrofile cylinder (key:key)
36
Kaba
QS 151.100.00
Double Europrofile cylinder (key:thumbturn)1
37
Medeco
BX664
Screw -in single cylinder
38
Medeco
BX665
Single Europrofile cylinder
39
Medeco
BX666
Double Europrofile cylinder (key:key)
40
Medeco
BX667
Double Europrofile cylinder (key:thumbturn)1
41
Medeco
BX668
Rim cylinder
42
Union
1x1
Rim cylinder
43
Union
2x18AA
Double Europrofile cylinder (key:key)
44
Union
2x19AA
Double Europrofile cylinder (key:thumbturn)1
45
Union
2x20A
Single Europrofile cylinder
46
Union
26x11B
Screw -in single cylinder
47
Yale
10026
Single Europrofile cylinder
48
Yale
1109.SCP
Rim cylinder
49
Yale
22626
Double Europrofile cylinder (key:key)
50
Yale
32626
Double Europrofile cylinder key:thumbturn)1
20 Nov 2011
353
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 51
Yale
PK1133 Pro-key
Screw -in single cylinder
52
Medeco
M3ARX MOTC-1001
Screw -in single cylinder
53
Medeco
M3ARX ESS-000-047
Single Europrofile cylinder
54
Medeco
M3ARX ETS-032-032
Double Europrofile cylinder (key:key)
55
Medeco
M3ARX ETT-032-032
Double Europrofile cylinder (key:thumbturn)1
56
Medeco
M3ARX RIMC-10516
Rim cylinder
57
AMS
CL-OVLD
Scandinavian Oval mechatronic cylinder7
58
AMS
CL-CA2D
Finish Round mechatronic cylinder7
Accessories
Accessory
Description
Compatible Doorsets (LPCB Cert. No. 516a/..) 014
Vision panels
03
04
054
06
07
Side panels 9
150 mm w ide by 350 mm high vision panels incorporating Tego S28 glazing units. Single timber side panels to either side of the doorset.
Over-panels 9
Single timber overhead panel.
Surface-mounted cable conduits
Cable conduits mounted on the non-attack face of the leaf, through w hich cables are routed to energise solenoid-operated locking systems. Cable conduits concealed w ithin the thickness of the leaf, through w hich cables are routed to energise solenoid-operated locking systems.
Concealed cable conduits
8
Supply voltage of solenoid-operated locking systems
Com patible Doorsets Configuration (LPCB Cert. No. 516a/..) 01 and 05 Plain doorset Doorset w ith vision panels Doorset w ith side panels Doorset w ith overhead panels 03, 04, 06 and 07
Plain doorset Doorset w ith side panels Doorset w ith overhead panels
Surface-m ounted cable conduits
Concealed cable conduits
12 V, 24 V and 50 V
12 V, 24 V and 50 V
12 V, 24 V and 50 V
12 V, 24 V and 50 V
50 V
50 V
12 V, 24 V and 50 V
10
12 V, 24 V and 50 V 10
12 V, 24 V and 50 V
-
50 V
-
12 V, 24 V and 50 V
10
-
Notes: 1. The ‘thumbturn’ end of the lock cylinder should be located on the non-attack side of the doorset when the doorset is installed. These cylinders are unsuitable for use with the Trimlock when fitted to the ‘46 mm thick’ version of the Sandhurst doorset. 2. The resistance of these access control locks to ‘non-mechanical’ attack has not been assessed as it is outside the scope of LPS1175. Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is ‘infinite’. It is therefore recommended that specifiers and installers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 3. This approval covers the use of Surelock McGill’s lock option codes R (12 V), R1 (24 V) and R4 (50 V). These reflect the supply voltage required and that the locks are configured in the ‘power to release’ mode. The actual voltages that are compatible on each doorset are identified in the table above entitled ‘Supply voltage of solenoid-operated locking systems’. 4. The vision panels are only approved on the Sandhurst doorsets when used in conjunction with lock options AA, AE, AF1, AD1, AG, AU, AQ and AR. 5. The approval covers the use of either the H3 or H21 versions of the push pad. 6. The approval covers the use of either the standard or H20 versions of the panic bar. 7. The resistance of the mechatronic cylinders to ‘non-mechanical’ attack has not been assessed as it is outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of ancillary equipment that may be used in conjunction with those cylinders. It is therefore recommended that specifiers satisfy themselves that the components used are either resistant to electronic methods of attack, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 8. Two locations are approved. These are both 375 mm from the leading edge of the leaf and either 625 mm or 1325 mm from the bottom of the leaf.
354
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 9. The side and overhead panels are available in fixed and removable variants of the configurations and overall dimensions defined on documents D12167.01 (Issue A) through to D12167.30 (Issue A). The approval only covers the provision of a single panel to each side of the doorset, and a single panel above the doorset. The provision of multiple panels in any direction is outside the scope of this approval. 10. Doorsets with overhead panels and cable conduits are compatible with 12 V, 24 V and 50 V solenoid-operated locking systems on the basis that cables are not routed via the overhead panels. Certificate No: 516c to LPS 1175: Issue 7
Hinged Doorsets Product Name
Product Type
Hendon
Single leaf inward opening doorset Single leaf outward opening doorset Double leaf1 inward opening doorset Double leaf1 outward opening doorset
Minimum Structural Opening Height (m) 1.9
Maximum Structural Opening Height (m) 2.5
Minimum Structural Opening Width (m) 0.7
Maximum Structural Opening Width (m) 1.4
Security Rating
Cert. No.
2
516c/01
1.9
2.5
0.7
1.4
2
1.9
2.5
1.4
3.0
22
1.9
2.5
1.4
3.0
22
Compatible Locking Systems
LPCB Ref. No.
Trade Nam e
Type
516c/01
Hendon Single leaf inw ard opening doorset
Nom imal Leaf Thickness (m m ) 46
54
Single leaf outw ard opening doorset
46
54
Double leaf inw ard opening doorset
46
54
Double leaf outw ard opening doorset
46 54
Com patible Locking System s Active Leaf
Passive Leaf
1, 2, 5, 6, 9, 10, 11, 12, 16, 17, 19, 20, 22, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42 and 43 1, 2, 3, 5, 6, 7, 8, 9, 10, 11, 12, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42 and 44 2, 5, 6, 9, 10, 11, 12, 16, 17, 19, 20, 22, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42 and 43 2, 3, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42 and 44 5, 6, 9, 10, 11, 12, 16, 17, 19, 20, 22, 25 and 26 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41 and 42 3, 5, 6, 7, 8, 9, 10, 11, 12, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25 and 26 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41 and 42 5, 6, 9, 10, 11, 12, 16, 17, 19, 20, 22, 25 and 26 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25 and 26
N/A
N/A
N/A
N/A
45 or tw o-point version of the active leaf lock 45 45 or tw o-point version of the active leaf lock 45 45 or tw o-point version of the active leaf lock 45 or tw o-point version of the active leaf lock
Compatible Locks
20 Nov 2011
355
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Locking System
Manufacturer
1
Dom Nemef
Nemef 642/17
2
Dom Nemef
Nemef 6602/32
3
Surelock McGill
4
Surelock McGill
5
Surelock McGill
6
Surelock McGill
SL301-0XO0W SL304-0XW SL305H3Q4 SL305-Q4
7
Surelock McGill
SL311-0XA0K0O0PW
8
Surelock McGill
SL311-0XK0O0PW
9
Surelock McGill
SL313A0K15P
10
Surelock McGill
SL313-A0P
16
Surelock McGill
17
Surelock McGill
SL315H3PW SL315-PW
18
Surelock McGill
SL322-0XK2O0R#PW
19
Surelock McGill
SL322-PR#
20
Surelock McGill
SL323K15PR#
21
Surelock McGill
SL323-P
22
Surelock McGill
SL323-PR#
23
Surelock McGill
24
Surelock McGill
25
Surelock McGill
356
Model
Type
External Face
Internal Face
Com patible Cylinders
Single-point mortice deadlock w ith internal quick release handle Single-point mortice deadlock
Key and lever handle
Lever handle
L to T
Key 3 and lever handle
U to AL
Slimline three-point surfacemounted locking system Slimline three-point surfacemounted locking system Slimline three-point surfacemounted locking system Slimline three-point surfacemounted locking system Slimline three-point surfacemounted locking system w ith manual bolting and deadlocking Slimline three-point surfacemounted locking system w ith manual deadlocking Slimline three-point surfacemounted locking system w ith manual bolting Slimline three-point surfacemounted locking system w ith manual bolting Slimline three-point surfacemounted locking system Slimline three-point surfacemounted locking system Slimline three-point surfacemounted locking system w ith fail secure solenoid6,7
None None
Key or thumbturn and lever handle Key and lever handle Panic bar 4
None
Push pad5
N/A
None
Lever handle
N/A
Key 3 and lever handle
Key and lever handle
A to K
Key 3 and lever handle
Key and lever handle
A to K
Slimline three-point surfacemounted locking system w ith fail secure solenoid6,7 Slimline three-point surfacemounted locking system w ith fail secure solenoid6,7 Slimline three-point surfacemounted locking system
Slimline three-point surfacemounted locking system w ith fail secure solenoid6,7 SL325-0XSlimline three-point surfaceH3K2O0R#P mounted locking system w ith fail W secure solenoid6,7 SL325-0XSlimline three-point surfaceK2O0R#PW mounted locking system w ith fail secure solenoid6,7 SL325H3PR#
Slimline three-point surfacemounted locking system w ith fail secure solenoid6,7
Operating Devices
3
Key 3 and lever handle
N/A N/A
Shrouded thumbturn and lever handle Key 3 and lever Thumbturn and handle lever handle
A to K
Key 3 and lever handle Key 3 and lever handle Electric release w ith key 3 override and lever handle Electric release and lever handle Electric release and lever handle Electric release and lever handle Electric release and lever handle Electric release w ith key 3 override and lever handle Electric release w ith key 3 override and lever handle Electric release and lever handle
Push pad5
A to K
Lever handle
A to K
Electric release and lever handle
A to K
Electric release and lever handle Shrouded thumbturn and lever handle Thumbturn and lever handle
A to K
A to K
A to K
A to K
Thumbturn and lever handle
A to K
Push pad5
A to K
Lever handle
A to K
Push pad5
A to K
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 26
Surelock McGill
SL325-PR#
27
Surelock McGill
28
Surelock McGill
ST105H3Q4 ST105-Q4
29
Surelock McGill
30
Surelock McGill
31
Surelock McGill
32
Surelock McGill
33
Surelock McGill
34
Surelock McGill
35
Surelock McGill
ST122K13PR#
36
Surelock McGill
ST122K2R#
37
Surelock McGill
ST123K13PR#
38
Surelock McGill
ST123K2R#
39
Surelock McGill
ST125H3K13PR#
40
Surelock McGill
ST125H3K2R#
41
Surelock McGill
ST125K13PR#
42
Surelock McGill
ST125K2R#
43
Surelock McGill
Trimlock DL117
44
Surelock McGill
Trimlock DL137
Three-point mortice locking system
Key 3 and lever handle
45
Surelock McGill
S3TB-W
Tow er bolts (2 off)
None
ST113K13P ST113-K2
ST115H3K13P ST115H3K2 ST115K13P ST115-K2
Slimline three-point surfaceElectric release w ith key 3 mounted locking system w ith fail 6,7 override and secure solenoid lever handle Stirling single-point surfaceNone mounted locking system Stirling single-point surfaceNone mounted locking system Stirling single-point surfaceKey 3 and lever mounted locking system handle Stirling single-point surfaceKey 3 and lever mounted locking system handle Stirling single-point surfaceKey 3 and lever mounted locking system handle Stirling single-point surfaceKey 3 and lever handle mounted locking system Stirling single-point surfaceKey 3 and lever mounted locking system handle Stirling single-point surfaceKey 3 and lever handle mounted locking system Electric release Stirling single-point surfacemounted locking system w ith fail and lever secure solenoid6,7 handle Stirling single-point surfaceElectric release w ith key 3 mounted locking system w ith fail 6,7 override and secure solenoid lever handle Electric release Stirling single-point surfaceand lever mounted locking system w ith fail handle secure solenoid6,7 Electric release Stirling single-point surfacew ith key 3 mounted locking system w ith fail 6,7 override and secure solenoid lever handle Stirling single-point surfaceElectric release mounted locking system w ith fail and lever secure solenoid6,7 handle Electric release Stirling single-point surfacew ith key 3 mounted locking system w ith fail override and secure solenoid6,7 lever handle Stirling single-point surfaceElectric release and lever mounted locking system w ith fail handle secure solenoid6,7 Electric release Stirling single-point surfacew ith key 3 mounted locking system w ith fail override and secure solenoid6,7 lever handle Three-point mortice locking Key 3 and lever system handle
Lever handle
A to K
Push pad5
N/A
Lever handle
N/A
Thumbturn and lever handle Thumbturn and lever handle Push pad5
A to T
Push pad5
A to T
Lever handle
A to T
Lever handle
A to T
Electric release and lever handle Electric release and lever handle
A to T
A to T
A to T
A to T
Thumbturn and lever handle
A to K
Thumbturn and lever handle
A to K
Push pad5
A to K
Push pad5
A to K
Lever handle
A to K
Lever handle
A to K
Key or thumbturn and lever handle Key or thumbturn and lever handle Tow er bolt
U to AL
U to AL
N/A
Compatible Cylinders
20 Nov 2011
357
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Cylinder Reference Manufacturer
Model
Type
A
Abloy
Disklock Pro CY405 DP
Rim cylinder
B
Assa
4857
Rim cylinder
C
Assa
Tw in Combi - C5857
Rim cylinder
D
Assa
Ruko Flexcore - F557
Rim cylinder
E
Bramah
C17
Rim cylinder
F
Dom
555ix10G
Rim cylinder
G
Kaba
KV06.100
Rim cylinder
H
Medeco
BX668
Rim cylinder
I
Medeco
M3ARX RIMC-10516
Rim cylinder
J
AMS
CL-OVLD
Scandinavian Oval mechatronic 8 cylinder
K
AMS
CL-CA2D
Finish Round mechatronic 8 cylinder
L
Abloy
Disklock Pro CY303 DP
Single europrofile cylinder
M
Assa
4823
Single europrofile cylinder
N
Assa
Ruko Flexcore - F523
Single europrofile cylinder
O
Assa
Tw in Combi - C5823
Single europrofile cylinder
P
Chubb
TXE3010
Single europrofile cylinder
Q
Dom
333 H RS5
Single europrofile cylinder
R
Kaba
QS 152.100.00
Single europrofile cylinder
S
Medeco
BX665
Single europrofile cylinder
T
Medeco
M3ARX ESS-000-047
Single europrofile cylinder
U
Abloy
Disklock Pro CY304 DP
Double europrofile cylinder (key:key)
V
Abloy
Disklock Pro CY305 DP
Double europrofile cylinder (key:thumbturn)9
W
Assa
4822
Double europrofile cylinder (key:key)
X
Assa
4824
Double europrofile cylinder (key:thumbturn)9
Y
Assa
Ruko Flexcore - F522
Double europrofile cylinder (key:key)
Z
Assa
Ruko Flexcore - F524
Double europrofile cylinder (key:thumbturn)9
AA
Assa
Tw in Combi - C5822
Double europrofile cylinder (key:key)
AB
Assa
Tw in Combi - C5821
Double europrofile cylinder (key:thumbturn)9
AC
Chubb
TXED3030
Double europrofile cylinder (key:key)
AD
Chubb
TXET3030
Double europrofile cylinder (key:thumbturn)9
AE
Dom
333 RS5
Double europrofile cylinder (key:key)
AF
Dom
333 K RS5
Double europrofile cylinder (key:thumbturn)9
AG
Kaba
QS 150.100.00
Double europrofile cylinder (key:key)
AH
Kaba
QS 151.100.00
Double europrofile cylinder (key:thumbturn)9
AI
Medeco
BX666
Double europrofile cylinder (key:key)
AJ
Medeco
BX667
Double europrofile cylinder (key:thumbturn)9
AK
Medeco
M3ARX ETS-032-032
Double europrofile cylinder (key:key)
AL
Medeco
M3ARX ETT-032-032
Double europrofile cylinder (key:thumbturn)9
Accessories
358
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Accessory Vision panels
Side panels 13
Description
Compatible Doorsets (LPCB Ref. No. 516c/01) 150 mm w ide by 350 mm high vision panels 10 incorporating ‘Tecdur DC28’ glazing 11 units. 150 mm w ide by 350 mm high vision panels 10 incorporating ‘Tecdur DC46’ glazing 12 units. Single timber side panel to either side of the doorset.
Overhead Single timber overhead panel. panels 13 Surface-mounted Cable conduits mounted on the non-attack face of the leaf, through w hich cables cable conduits are routed to energise solenoid-operated locking systems.
Concealed cable Cable conduits concealed w ithin the thickness of the leaf, through w hich cables conduits are routed to energise solenoid-operated locking systems.
Supply Voltage of Solenoid-Operated Locking Systems
Configuration Doorset w ith cable conduits
Com patible Doorsets (LPCB Ref. No. 516c/0114) 12 V, 24 V and 50 V
Doorset w ith side panels and cable conduits
12 V, 24 V and 50 V
Doorset w ith overhead panels and cable conduits
12 V, 24 V and 50 V
Doorset w ith vision panels and cable conduits
12 V, 24 V and 50 V
Notes: 1. The approval only covers double leaf doorsets with leafs of equal width. 2. The doorset achieves a Security Rating 2 classification when placed in the optimum locked condition. A Security Rating 1 classification prevails when placed in the minimum locked condition. That condition exists when either: a. One tower bolt is engaged, the active leaf locking system is engaged and the external key is removed. b. The two-point manual bolting version of the locking system fitted to the active leaf was disengaged, the active leaf locking system is engaged and the external key is removed. 3. The external cylinder is protected within a Surelock McGill ‘P’ cylinder guard. 4. The approval covers the use of either the standard or H20 versions of the panic bar. 5. The approval covers the use of either the H3 or H21 versions of the push pad. 6. This approval covers the use of Surelock McGill’s lock option codes R (12 V), R1 (24 V) and R4 (50 V). These reflect the supply voltage required and that the locks are configured in the ‘power to release’ mode. The actual voltages that are compatible on each doorset are identified in the table above entitled ‘Supply voltage of solenoid-operated locking systems’. 7. The resistance of these access control locks to ‘non-mechanical’ attack has not been assessed as it is outside the scope of LPS1175. Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is ‘infinite’. It is therefore recommended that specifiers and installers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 8. The resistance of the mechatronic cylinders to ‘non-mechanical’ attack has not been assessed as it is outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of ancillary equipment that may be used in conjunction with those cylinders. It is therefore recommended that specifiers satisfy themselves that the components used are either resistant to electronic methods of attack, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 9. The ‘thumbturn’ end of the lock cylinder should be located on the non-attack side of the doorset when the doorset is installed. 10. Two locations are approved. These are both 375 mm from the leading edge of the leaf and either 625 mm or 1325 mm from the bottom of the leaf. 11. ‘Tecdur DC28’ glazing units should not be used in combination with locking systems 4, 13, 14 or 15. 12. ‘Tecdur DC46’ glazing units should not be used in combination with locking systems 1 to 3, 5 to 12 or 16 to 44. 13. The side and overhead panels are available in fixed and removable variants of the configurations and overall dimensions defined on documents D12167.01 (Issue A) through to D12167.30 (Issue A). The approval only covers the provision of a single panel to each side of the doorset, and a single panel above the doorset. The provision of multiple panels in any direction is outside the scope of this approval. 14. ‘Hendon’ doorsets may incorporate surface-mounted or concealed cable conduits, as illustrated on documents D12183.06 (Issue A) and D12183.07 (Issue A).
20 Nov 2011
359
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
Sunray Engineering Limited Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137 E-mail: [email protected] • Website: www.sunraydoors.co.uk Certificate No: 234c to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
ExcluDoor 3
Double leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset10 Single leaf, outward opening hinged security doorset with multipoint locking systems Single leaf, outward opening hinged security doorset Single leaf, outward opening hinged security doorset with two single point locks Single leaf, outward opening hinged security doorset with a single point lock Double leaf, outward opening hinged security doorset with multi point locking systems10 Single leaf, outward opening hinged security doorset with multi point locking systems
ExcluDoor 4
ExcluDoor 3 ExcluDoor 4
ExcluDoor 4 F.R. ExlcuDoor 4 F.R.
Minimum Clear Opening Height (m) 1.8
Maximum Clear Opening Height (m) 2.4
Minimum Clear Opening: Width (m) 1.4
Maximum Clear Opening: Width (m) 2.4
Security Rating
Cert. No.
3
234c/01
1.8
2.4
1.24
2.4
4
234c/02
1.8
2.4
0.75
1.24
4
234c/03
-
2.25
-
1.1
3
234c/04
1.8
2.25
0.75
1.24
4
234c/05
1.8
2.4
0.75
1.24
4
234c/06
1.8
2.4
1.24
2.4
4
234c/07
1.8
2.4
0.75
1.24
4
234c/08
Approved Locking Configurations
LPCB Ref. No.
Trade Name
Com patible Locking Devices Active Leaf
Passive Leaf
234c/01
ExcluDoor 3
11, 12 or 32
9
234c/02
ExcluDoor 4
1, 2, 31, 41, 5, 6, 7, 8, 10, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30 or 31 11, 12 or 32
13 or 14 9
234c/03
ExcluDoor 4
6, 7, 8, 15, 16, 17, 18, 19 or 30
N/A
234c/04
ExcluDoor 3
1 or 2
N/A
234c/05
ExcluDoor 49
3 or 41
N/A
234c/06
ExcluDoor 4
1, 2, 20, 21, 22, 23, 24, 25, 26, 27, 28 or 29
N/A
234c/07
ExcluDoor 4 F.R.
7
13 or 14
234c/08
ExcluDoor 4 F.R.
7
N/A
Compatible Locking Systems
360
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Com patible Locking System
Locking System
Type
Com patible Operating Devices External Face Key
1
Assa765
Sash lock
2 3
5 6 7 8
Assa 2788 Assa 7653 Assa 27884 Assa 7653 Assa 7654 Assa Mico 942-10 Assa Mico 942-3p Surelock McGill EX210 (B1) Surelock McGill EX210 (B1)
Dead lock Sash lock Deadlock Sash lock Sash lock 2-w ay panic 3-w ay panic 3-w ay panic 3-w ay panic
9 10
Surelock McGill EX212 (B2) Surelock McGill EX212 (B2)
2-w ay panic exit device 2-w ay panic exit device
11 12
Surelock McGill EX213 (B3) Surelock McGill EX213 (B3)
3-bolt panic exit device 3-bolt panic exit device
13
15 16
Sunray “D/40083” internal drop bolt Sunray “D/40015” surface mounted drop bolt Surelock McGill A1 Surelock McGill A1
17 18 19 20
Surelock McGill D3- K13P56 Surelock McGill D6 K13P56 Surelock McGill C1 K13P56 EX800
21
EX800 w ith K13P5 option
22
DL800
Tw o concealed leading edge drop bolts Tw o surface mounted high N/A security barrel bolts 3-w ay locking device None 3-w ay locking device Key and handle (LEO L1P) 3-w ay locking device Key and handle 3-w ay locking device Key and handle 3-w ay locking device Key and handle Single point emergency exit None device Single point emergency exit Key and handle device Single point deadlock None
23
DL800 w ith K13P5 option
Single point deadlock
Key and handle
24
DL800 w ith K13P5 option
Single point deadlock
None
25
DL800 w ith K4 and K13P5 option
Single point deadlock
Key and handle
4
14
20 Nov 2011
exit device exit device exit device exit device
Key Key Key Key Key None None None Key and handle (LEO L1P) None Key and handle (LEO L1P) None Key and handle (LEO L1P) N/A
Com patible Cylinders
Internal Face Key 2 or Thumbturn5 Blind rose Key 2 Thumbturn Blind rose Thumbturn Thumbturn Push pad Push pad Panic bar Panic bar
B or D A or C A or C A or C A or C N/A N/A N/A S to W
Panic bar Panic bar
N/A S to W
Panic bar Panic bar
N/A S to W
A to D
N/A
N/A
N/A
N/A
Handle Handle
N/A S to W
Handle Handle Handle Handle
E to R E to R E to R N/A
Handle
E to R
Thumb turn and handle Thumb turn and handle Break dome protection turn knob and handle Break dome protection turn knob and handle
N/A E to R N/A
E to R
361
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 26
AC800
Single point electromechanical access control lock pow ered by 12V, 24V or 50 V solenoid7, 8
27
AC800 w ith X option
Single point electromechanical access control lock pow ered by 12V, 24V or 50 V solenoid7, 8
28
AC800 w ith K13P5 option
Single point electromechanical access control lock pow ered by 12V, 24V or 50 V solenoid7, 8
29
AC800 w ith K13P5 and K9 options
Single point electromechanical access control lock pow ered by 12V, 24V or 50 V solenoid7, 8
30
Surelock McGill EX210 (B1)
3-w ay panic exit device
31
Surelock McGill EX212 (B2)
2-w ay panic exit device
32
Surelock McGill EX213 (B3)
3-bolt panic exit device
Handle plus external access control entry device (e.g. key pad or sw ipe card etc) Handle plus external access control entry device (e.g. key pad or sw ipe card etc) Handle plus external access control entry device (e.g. key pad or sw ipe card etc) Handle plus external access control entry device (e.g. key pad or sw ipe card etc) Key and handle (LEO L2) Key and handle (LEO L2) Key and handle (LEO L2)
Handle
N/A
Handle
N/A
Handle
E to R
Handle and thumbturn
E to R
Panic bar
T to AE
Panic bar
T to AE
Panic bar
T to AE
Compatible Cylinders
Cylinder Reference A B C D E F G H I J K L M N O P Q R S T U
362
Manufacturer Assa Assa Assa Assa Abloy Abloy Assa Assa Assa Bramah Dom Kaba Medeco Medico Union Yale AMS AMS Winkhaus Union Abloy
Model 601 602 Tw in Combi C5801 Tw in Combi C5802 CY405DP CY405PT 4857 C5857 Ruko Flexcore - F557 C17 555ix10G KV06.100 BX668 M3 ARX 1x1 1109.SCP CL-OVLD11 CL-CA2D11 VS629 26x11B CY404DP
Type Oval profile cylinder Oval profile cylinder Oval profile cylinder Oval profile cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Rim cylinder Scandinavian oval profile mechatronic cylinder Finnish Round profile mechatronic cylinder Screw -in cylinder Screw -in cylinder Screw -in cylinder
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES V W X Y Z AA AB AC AD AE
Abloy Assa Assa Assa Bramah Dom Kaba Medico Medico Yale
CY404PT Tw in-Combi C5851 4851 F551 C17SI 419ix10KG K207.203 C5-SC 664 M3ARX MOTC-1001 PK1133 ProKey
Screw -in cylinder Screw -in cylinder Screw -in cylinder Screw -in cylinder Screw -in cylinder Screw -in cylinder Screw -in cylinder Screw -in cylinder Screw -in cylinder Screw -in cylinder
Notes: 1. In order to achieve the required security rating, both locks must be activated. 2. The security rating will not be achieved if the key is left in the lock on the inside of the door or if the door is placed in the emergency exit mode. 3. Lock fitted to the upper lock position. 4. Lock fitted to the lower lock position. 5. The D/40047/L thumbturn protection shroud shall be fitted when this hardware is fitted to the ExcluDoor 4 double doorset. 6. Device must be deadlocked if the doorset is to provide resistance to attack commensurate with Security Rating 4. 7. Fail secure version only. 8. The resistance of the access control locks to “non-mechanical” attack has not been assessed as it is outside the scope of LPS1175. Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that Sunray Engineering satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 9. The ExcluDoor 4 single leaf doorset (certificate number 234c/05) is also certified for 30 minutes integrity against the requirements of LPS1056: Issue 5. See LPCB Certificate No. 234b or Volume 2, Part 2, Section 1.1 of the Red Book for details. 10. The ExcluDoor 4 double leaf doorset can be produced with leafs of unequal width. The maximum width of both leaves is 1173.5 mm. The minimum width of active leaf approved is 615 mm and the minimum width of passive leaf approved is 300 mm. 11. The resistance of the mechatronic cylinders to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of ancillary equipment that may be used in conjunction with those cylinders. It is therefore recommended that specifiers satisfy themselves that the components used are either resistant to electronic methods of attack, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. Certificate No: 234d to LPS 1175: Issue 7
Hinged Security Doorsets Product Name
Type
ExcluDoor 3 Mk2
Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset1 Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset2 Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset3 Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset3 Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset4 Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset4
ExecDoor 2
ExcluDoor 4 Mk2
ExcluDoor 4 Mk2 F.R. ExcluDoor 5
ExcluDoor 4 Mk3
20 Nov 2011
Minimum Clear Opening Height (m) 1.8
Maximum Clear Opening Height (m) 2.4
Minimum Clear Opening Width (m) 0.75
Maximum Clear Opening Width (m) 1.24
Security Rating
Cert. No.
3
234d/01
1.8
2.4
1.24
2.4
3
234d/02
1.8
2.2
0.75
1.3
2
234d/03
1.8
2.2
1.5
2.5
2
234d/04
1.8
2.4
0.75
1.24
4
234d/05
1.8
2.4
1.24
2.4
4
234d/06
1.8
2.4
0.75
1.24
4
234d/07
1.8
2.4
1.24
2.4
4
234d/08
1.8
2.4
0.75
1.24
5
234d/09
1.8
2.4
1.24
2.4
5
234d/10
1.8
2.4
0.75
1.24
4
234d/11
1.8
2.4
1.24
2.4
4
234d/12
363
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Product Name
Type
ExcluDoor 3 Mk3 F.R.
Single leaf, outward opening hinged security doorset Double leaf, outward opening hinged security doorset3
Minimum Clear Opening Height (m) 1.8
Maximum Clear Opening Height (m) 2.4
Minimum Clear Opening Width (m) 0.75
Maximum Clear Opening Width (m) 1.24
Security Rating
Cert. No.
3
234d/13
1.8
2.4
1.24
2.4
3
234d/14
Approved Locking Configurations
LPCB Ref. No.
Product Name
Type
Com patible Locking System s Active Leaf
Passive Leaf
234d/01
ExcluDoor 3 Mk2
Single leaf, outw ard opening hinged security doorset
1 to 51
-
234d/02
ExcluDoor 3 Mk2
Double leaf, outw ard opening hinged security doorset
1 to 51
52 or 53
234d/03
ExecDoor 2
Single leaf outw ard opening hinged security doorset
54 to 60
-
234d/04
ExecDoor 2
Double leaf outw ard opening hinged security doorset
54 to 60
61 or 62
234d/05
ExcluDoor 4 Mk2
Single leaf, outw ard opening hinged security doorset
63 to 80
N/A
234d/06
ExcluDoor 4 Mk2
Double leaf, outw ard opening hinged security doorset
63 to 71
52 or 53
234d/07
ExcluDoor 4 Mk2 F.R.
Single leaf, outw ard opening hinged security doorset
63 to 71
N/A
234d/08
ExcluDoor 4 Mk2 F.R.
Double leaf, outw ard opening hinged security doorset
63 to 71
52 or 53
234d/09
ExcluDoor 5
Single leaf, outw ard opening hinged security doorset
81 to 102
N/A
234d/10
ExcluDoor 5
Double leaf, outw ard opening hinged security doorset
81 to 102
52 or 53
234d/11
ExcluDoor 4 Mk3
Single leaf, outw ard opening hinged security doorset
81 to 102
N/A
234d/12
ExcluDoor 4 Mk3
Double leaf, outw ard opening hinged security doorset
81 to 102
52 or 53
234d/13
ExcluDoor 3 Mk3 F.R.
Single leaf, outw ard opening hinged security doorset
63 to 71
N/A
234d/14
ExcluDoor 3 Mk3 F.R.
Double leaf, outw ard opening hinged security doorset
63 to 71
52 or 53
Compatible Locking Systems
Com patible Manufacturer Locking System s 1 2 3 4 5
6
364
Model
Type
Surelock McGill Stirling EX800 Single point emergency Limited exit device Surelock McGill Stirling EX800 w ith Single point emergency Limited K13P option exit device Surelock McGill Stirling DL800 Single point deadlock Limited Surelock McGill Stirling DL800 w ith Single point deadlock Limited K13P option Surelock McGill Stirling DL800 w ith Single point deadlock Limited K4 option Surelock McGill Stirling DL800 w ith Limited K4 and K13P option
Single point deadlock
Com patible Operating Devices
Com patible Cylinders
External Face
Internal Face
None
Handle
N/A
Key and handle
Handle
None
Thumb turn and handle Thumb turn and handle Break dome protection turn knob and handle Break dome protection turn knob and handle
Z, AB to AI, AX N/A
Key and handle None
Key and handle
Z, AB to AI, AX N/A
Z, AB to AI, AX
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 7
Surelock McGill Limited
8
Surelock McGill Stirling AC800 w ith Limited X option
Single point electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5
9
Surelock McGill Stirling AC800 w ith Limited K13P option
Single point electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5
10
Surelock McGill Stirling AC800 w ith Limited K13P and K9 options
Single point electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5
11
Surelock McGill Limited Surelock McGill Limited Surelock McGill Limited
12 13
14
Stirling AC800
Single point electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5
Handle plus external access control entry device (e.g. key pad or sw ipe card etc) 6 Handle plus external access control entry device (e.g. key pad or sw ipe card etc) 6 Handle and key or external access control entry device (e.g. key pad or sw ipe card etc.)6
Handle
N/A
Handle
N/A
Handle
Z, AB to AI, AX
Handle and key or external access control entry device (e.g. key pad or sw ipe card etc.)6
Handle and thumb turn
Z, AB to AI, AX
Push pad
N/A
Panic bar
N/A
Push pad
BB, BC, BE, BI BB, BC, BE, BI Z, AB to AI, AX
Slimline 3-w ay emergency exit None SL305-00-H3 device Slimline 3-w ay panic exit device None SL304-00 Slimline 3-w ay emergency exit Key and handle SL305-0x-H3Lon device (LEO L1P)
Surelock McGill Limited Surelock McGill Limited
Slimline SL304-0x-Lon Slimline SL324-0xK2OnPRn
3-w ay panic exit device Key and handle (LEO L1P) 3-w ay panic exit device Handle and key w ith electro-mechanical or external access control lock access control pow ered by 12 V, 24 V entry device or 50 V solenoid5 (e.g. key pad or sw ipe card etc.)6
Panic bar
16
Surelock McGill Limited
Slimline SL325-0xH3K2OnPRn
3-w ay emergency exit Handle and key or external device w ith electroaccess control mechanical access entry device control lock pow ered by 12 V, 24 V or 50 V (e.g. key pad or sw ipe card etc.)6 solenoid5
Push pad
Z, AB to AI, AX
17
Surelock McGill Limited
Slimline SL325-0xK2OnPRn
3-w ay emergency exit Handle and key or external device w ith electroaccess control mechanical access entry device control lock pow ered by 12 V, 24 V or 50 V (e.g. key pad or sw ipe card etc.)6 solenoid5
Handle
Z, AB to AI, AX
15
20 Nov 2011
Panic bar
365
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 18 19 20 21 22 23 24 25 26
Key and handle (LEO L2) Key and handle (LEO L2) Key and handle (ELK3) None
Push pad
BB to BH
Panic bar
BB to BH
Panic bar
AM to AZ
Panic bar
N/A
Key and handle (ELK3) None
Push pad
AM to AZ
Push pad
N/A
Key and handle (ELK3) None
Lever handle
AM to AZ
Lever handle
N/A
None
Thumb turn and lever handle
N/A
Thumb turn and full w idth push plate7 Thumb turn and push pad Thumb turn and lever handle
N/A
27
Tindall Engineering Ltd
Mico 942 INT MD
2-w ay locking system w ith manual deadlock
None
28
Tindall Engineering Ltd Tindall Engineering Ltd
Mico 942P INT MD
2-w ay locking system w ith manual deadlock 2-w ay locking system w ith manual deadlock
None
29 30 31 32 33 34 35 36 37
38
366
Surelock McGill Slimline 3-w ay emergency exit Limited SL305-0x-H3L2on device Surelock McGill Slimline 3-w ay panic exit device Limited SL304-0x-L2on Tindall Mico 942 / ELK 3 2-w ay panic exit device Engineering Ltd Tindall Mico 942 2-w ay panic exit device Engineering Ltd Tindall Mico 942P / ELK 3 2-w ay emergency exit Engineering Ltd device Tindall Mico 942P 2-w ay emergency exit Engineering Ltd device Tindall Mico 942L / ELK 3 2-w ay emergency exit Engineering Ltd device Tindall Mico 942L 2-w ay emergency exit Engineering Ltd device Tindall Mico 942L INT AD 2-w ay locking system Engineering Ltd w ith automatic deadlock
Mico 942L INT MD
Tindall Mico 942-3 / ELK 3 Engineering Ltd Tindall Mico 942-3 Engineering Ltd Tindall Mico 942-3P / ELK Engineering Ltd 3 Tindall Mico 942-3P Engineering Ltd Tindall Mico 942-3L / ELK Engineering Ltd 3 Tindall Mico 942-3L Engineering Ltd Tindall Mico 942-3L INT Engineering Ltd AD Tindall Mico 942-3 INT MD Engineering Ltd Tindall Engineering Ltd
Mico 942-3P INT MD
None
N/A N/A
3-w ay panic exit device Key and handle (ELK3) 3-w ay panic exit device None
Panic bar
AM to AZ
Panic bar
N/A
3-w ay emergency exit Key and handle device (ELK3) 3-w ay emergency exit None device 3-w ay emergency exit Key and handle device (ELK3) 3-w ay emergency exit None device 3-w ay locking system None w ith automatic deadlock 3-w ay locking system None w ith manual deadlock
Push pad
AM to AZ
Push pad
N/A
Lever handle
AM to AZ
Lever handle
N/A
Thumb turn and lever handle Thumb turn and full w idth push plate7 Thumb turn and push pad
N/A
3-w ay locking system w ith manual deadlock
None
N/A
N/A
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 39 40
41
42
Tindall Engineering Ltd Tindall Engineering Ltd
Mico 942-3L INT MD Mico 942 EM SEC
3-w ay locking system None Thumb turn and w ith manual deadlock lever handle 2-w ay locking system Access control Access control w ith automatic deadlock system and lever and thumb turn handle5,6 override w ith full w idth push plate7 Tindall Mico 942P EM SEC 2-w ay locking system Access control Access control Engineering Ltd w ith automatic deadlock system and lever and thumb turn handle5,6 override w ith push pad Tindall Mico 942L EM SEC 2-w ay locking system Access control Access control Engineering Ltd w ith automatic deadlock system and lever and thumb turn handle5,6 override w ith lever handle
N/A N/A
N/A
N/A
43
Tindall Mico 942 SATE EM 2-w ay panic exit device Access control w ith automatic system and lever Engineering Ltd SEC handle5,6 deadlocking
Panic bar
N/A
44
Tindall Engineering Ltd
Push pad
N/A
45
Tindall Engineering Ltd
46
Mico 942P SATE EM SEC
2-w ay emergency exit Access control device w ith automatic system and lever handle5,6 deadlocking
Lever handle 2-w ay emergency exit Access control device w ith automatic system and lever handle5,6 deadlocking Tindall Mico 942-3 EM SEC 3-w ay locking system Access control Access control system and lever and thumb turn Engineering Ltd w ith automatic handle5,6 override w ith full deadlocking w idth push plate7 Mico 942L SATE EM SEC
N/A
N/A
47
Tindall Engineering Ltd
Mico 942-3P EM SEC
3-w ay locking system Access control system and lever w ith automatic handle5,6 deadlocking
Access control and thumb turn override w ith push pad
N/A
48
Tindall Engineering Ltd
Mico 942-3L EM SEC
3-w ay locking system Access control system and lever w ith automatic handle5,6 deadlocking
N/A
49
Tindall Engineering Ltd
Access control and thumb turn override w ith lever handle Panic bar
Push pad
N/A
Lever handle
N/A
50
51
Mico 942-3 SATE 3-w ay panic exit device w ith automatic EM SEC deadlocking Tindall Mico 942-3P SATE 3-w ay emergency exit Engineering Ltd EM SEC device w ith automatic deadlocking Tindall Mico 942-3L SATE 3-w ay emergency exit Engineering Ltd EM SEC device w ith automatic deadlocking
20 Nov 2011
Access control system and lever handle5,6 Access control system and lever handle5,6 Access control system and lever handle5,6
N/A
367
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 52
Sunray Sunray surface Tw o surface mounted Engineering Ltd mounted drop bolts drop bolts
None
Surface mounted drop bolts
N/A
53
Sunray internal drop bolts 765
Tw o internal drop bolts
None
Sash lock
55
Assa
765
Sash lock
56
Assa
2788
Dead lock
Key and lever handle Key and lever handle Key
Internal drop bolts Key and lever handle Thumbturn and lever handle Key
N/A
54
Sunray Engineering Ltd Assa
57
Assa
2788
Dead lock
Key
Thumbturn
AS
58
Exidor
803
None
Panic bar
N/A
59
Exidor
803 w ith 809
Panic bar
Y
60
Exidor
803 w ith 810
Key and turn knob (Exidor 809) Key and handle (Exidor 810)
Panic bar
Y
61
Exidor
802
None
Panic bar
N/A
AS BA
62
Exidor
HS923/10
Three point panic exit device8 Three point panic exit device w ith outside access device8 Three point panic exit device w ith outside access device8 Tw o point panic exit device9 Tw o tow er bolts
None
Tow er bolts
N/A
63
Surelock McGill Limited Surelock McGill Limited
Slimline SL301
Three point deadlock
None
N/A
Slimline SL303
Three point deadlock
None
Surelock McGill Limited Surelock McGill Limited Surelock McGill Limited
Slimline SL305
Internal key and handle Thumb turn and handle (K4 breakdome optional) Handle
64
65 66 67
68 69
70
368
BA
Surelock McGill Limited Surelock McGill Limited
Surelock McGill Limited
Three point emergency exit device Slimline SL311-P5 Three point deadlock Slimline SL313-P5
Three point deadlock
Slimline SL315-P5 Three point emergency exit device Slimline SL321-P5 Three point deadlock incorporating electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5,6 Slimline SL323-P5 Three point deadlock incorporating electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5,6
None
N/A
N/A
Key and lever handle Key and lever handle
Internal key and Z, AB to AI, handle AX Thumb turn and Z, AB to AI, handle (K4 breakAX dome optional) Key and lever Handle Z, AB to AI, handle AX Handle plus Internal key/ Z, AB to AI, external access access control AX control entry and handle device and key override Handle plus external access control entry device and key override
Thumb turn/ access control and handle (K4 break-dome optional)
Z, AB to AI, AX
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 71
Surelock McGill Limited
72
Surelock McGill Limited Surelock McGill Limited
73
74 75 76
77 78
Surelock McGill Limited Surelock McGill Limited Surelock McGill Limited
Surelock McGill Limited Surelock McGill Limited
Slimline SL325-P5 Three point emergency exit device incorporating electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5,6 Stirling ST101 Single point deadlock
N/A
None
Stirling ST111-P5
Single point emergency exit device Single point deadlock
Stirling ST113-P5
Single point deadlock
Stirling ST115-P5 Stirling ST121-P5
Surelock McGill Limited
Stirling ST125-P5
81
Surelock McGill Limited Surelock McGill Limited
Slimline SL305
20 Nov 2011
Internal key and handle Thumb turn and handle (K4 breakdome optional) Handle
Stirling ST105
80
84
None None
Stirling ST123-P5
Surelock McGill Limited Surelock McGill Limited
Z, AB to AI, AX
Single point deadlock
Surelock McGill Limited
83
Handle
Stirling ST103
79
82
Handle plus external access control entry device and key override
Slimline SL303
Slimline SL301
Key and lever handle Key and lever handle
Single point emergency Key and lever exit device handle Handle plus Single point deadlock incorporating electro- external access control entry mechanical access device and key control lock pow ered override by 12V, 24V or 50V solenoid5,6 Single point deadlock Handle plus incorporating electro- external access mechanical access control entry control lock pow ered device and key by 12V, 24V or 50V override solenoid5,6 Handle plus Single point emergency external access exit device control entry incorporating electrodevice and key mechanical access override control lock pow ered by 12V, 24V or 50V solenoid5,6 Three point emergency None exit device Three point deadlock None
Three point deadlock
Slimline SL315-P6 Three point emergency exit device
None Key and lever handle
N/A
N/A
Internal key and Z, AB to AI, handle AX Thumb turn and Z, AB to AI, handle (K4 breakAX dome optional) Handle Internal key/ access control and handle
Z, AB to AI, AX Z, AB to AI, AX
Thumb turn/ access control and handle (K4 break-dome optional)
Z, AB to AI, AX
Handle
Z, AB to AI, AX
Handle
N/A
Thumb turn and handle (K4 breakdome optional)
N/A
Internal key and handle Handle
N/A Z, AB to AI, AX
369
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 85
Surelock McGill Limited
Slimline SL313-P6
Three point deadlock
Key and lever handle
86
Surelock McGill Limited Surelock McGill Limited
Slimline SL311-P6
Three point deadlock
Key and lever handle Handle plus external access control entry device and key override
87
88
Surelock McGill Limited
89
Surelock McGill Limited
90
Tindall Engineering Ltd Tindall Engineering Ltd Tindall Abryll EPC AD3 Single point deadlock None Engineering Ltd Tindall Abryll SATE AD3 Single point emergency Key and lever Engineering Ltd USCH5 exit device handle Tindall Abryll SATE EPC Single point emergency Key and lever Engineering Ltd AD3 USCH5 exit device handle Tindall Abryll AD3 USCH5 Single point deadlock Key and lever Engineering Ltd handle Tindall Abryll EPC AD3 Single point deadlock Key and lever Engineering Ltd USCH5 handle Tindall Abryll EPC AD3 Single point deadlock Key and lever Engineering Ltd USCH5 handle Tindall Abryll SATE EM3 Single point emergency Handle plus Engineering Ltd USCH5 exit device external access incorporating electrocontrol entry mechanical access device and key control lock pow ered override by 12V, 24V or 50V solenoid5.6
91 92 93 94 95 96 97 98
370
Slimline SL325-P6 Three point emergency exit device incorporating electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5.6 Handle plus Slimline SL323-P6 Three point deadlock incorporating electro- external access control entry mechanical access device and key control lock pow ered override by 12V, 24V or 50V solenoid5.6 Handle plus Slimline SL321-P6 Three point deadlock incorporating electro- external access control entry mechanical access device and key control lock pow ered override by 12V, 24V or 50V solenoid5.6 Abryll PE3 Single point emergency None exit device Abryll AD3 Single point deadlock None
Thumb turn and Z, AB to AI, handle (K4 breakAX dome optional) Internal key and handle Handle
Z, AB to AI, AX Z, AB to AI, AX
Thumb turn/ access control and handle (K4 break-dome optional)
Z, AB to AI, AX
Internal key/ access control and handle
Z, AB to AI, AX
Handle
N/A
Thumb turn and handle Internal key and handle Handle
N/A
Handle
A to K Z, AA, AH to AL, AN to AZ A to K
Thumb turn and Z, AA, AH to handle AL, AN to AZ Thumb turn and L to X handle Internal key and A to K handle Handle Z, AA, AH to AL, AN to AZ
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES 99
100
101
102
Tindall Engineering Ltd
Abryll EPC SATE EM3 USCH5
Single point emergency exit device incorporating electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5.6 Tindall Abryll EPC EM3 Single point deadlock Engineering Ltd USCH5 incorporating electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5.6 Tindall Abryll EM3 USCH5 Single point deadlock Engineering Ltd incorporating electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5.6 Tindall Abryll EPC EM3 Single point deadlock Engineering Ltd USCH5 incorporating electromechanical access control lock pow ered by 12V, 24V or 50V solenoid5.6
Handle plus external access control entry device and key override
Handle
A to K
Handle plus external access control entry device and key override
Thumb turn/ access control and handle
L to X
Handle plus external access control entry device and key override
Thumb turn/ access control and handle
Z, AA, AH to AL, AN to AZ
Handle plus external access control entry device and key override
Internal key/ access control and handle
A to K
Compatible Cylinders
Cylinder Reference A
Manufacturer
Model
Type
Abloy
CY304 Protec
Europrofile double cylinder (key:key)
‘Plus’ rating 10 +
B
Access2
Tigres Omega
Europrofile double cylinder (key:key)
+
C
Assa
4822
Europrofile double cylinder (key:key)
D
Assa
7622
Europrofile double cylinder (key:key)
E
Assa
C5822
Europrofile double cylinder (key:key)
F
Assa
dp4422
Europrofile double cylinder (key:key)
G
Kaba
Gege RAM
Europrofile double cylinder (key:key)
+
H
Kaba
Quattro PluS
Europrofile double cylinder (key:key)
+
I
Medeco
M3-ARX
Europrofile double cylinder (key:key)
+
J
Abloy
CY304 Protec Cliq
Europrofile double cylinder (key:key) (mechatronic)
+
K
Assa
44M22 Cliq
Europrofile double cylinder (key:key) (mechatronic)
L
Abloy
CY305 Protec
Europrofile double cylinder (key:thumbturn)
20 Nov 2011
11
11
+
371
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
372
M
Abloy
CY333 Protec (PT)
Europrofile double cylinder (key:thumbturn)
+
N
Access2
Tigres Omega
Europrofile double cylinder (key:thumbturn)
+
O
Assa
4827
Europrofile double cylinder (key:thumbturn)
P
Assa
7627
Europrofile double cylinder (key:thumbturn)
Q
Assa
44M27 Cliq11
Europrofile double cylinder (key:thumbturn)
R
Assa
C5827
Europrofile double cylinder (key:thumbturn)
S
Assa
dp4427
Europrofile double cylinder (key:thumbturn)
T
Kaba
Gege RAM
Europrofile double cylinder (key:thumbturn)
+
U
Kaba
Quattro PluS
Europrofile double cylinder (key:thumbturn)
+
V
Medeco
M3-ARX
Europrofile double cylinder (key:thumbturn)
+
W
Abloy
CY305 Protec Cliq
+
X
Abloy
CY333 Protec Cliq 11
Y
Zone
1850
Europrofile double cylinder (key:thumbturn) (mechatronic) Europrofile double cylinder (key:thumbturn) (mechatronic) Europrofile single cylinder
Z
AMS
CL-CA2D11
Finnish Round cylinder (mechatronic)
+
11
+
AA
Abloy
CY403 Protec
Rim cylinder
+
AB
Abloy
CY405 Disklock Pro (DP)
Rim cylinder
+
AC
Abloy
CY405 ProTec (PT)
Rim cylinder
+
AD
Assa
4857
Rim cylinder
AE
Assa
C5857
Rim cylinder
AF
Bramah
C17
Rim cylinder
AG
Kaba
K20
Rim cylinder
AH
Kaba
Quattro PluS
Rim cylinder
+
AI
Medico
M3ARX
Rim cylinder
+
AJ
Abloy
CY403 Protec Cliq 11
Rim cylinder (mechatronic)
+
AK
Assa
4857
Round threaded cylinder
AL
Assa
C5857
Round threaded cylinder
AM
Abloy
CY201 Disklock Pro (DP)
Scandinavian Oval cylinder
+
AN
Abloy
CY201 Protec (PT)
Scandinavian Oval cylinder
+
AO
Abloy
CY201 Protec Cliq 11
Scandinavian Oval cylinder
+
AP
Access2
Tigres Omega
Scandinavian Oval cylinder
+
AQ
Assa
4801
Scandinavian Oval cylinder
AR
Assa
7601
Scandinavian Oval cylinder
AS
Assa
C5801
Scandinavian Oval cylinder
AT
Assa
dp4401
Scandinavian Oval cylinder
AU
Kaba
K20
Scandinavian Oval cylinder
AV
Kaba
Quattro PluS
Scandinavian Oval cylinder
+
AW
Medeco
M3-ARX
Scandinavian Oval cylinder
+
AX
AMS
CL-OVLD11
Scandinavian Oval cylinder (mechatronic)
+
AY
Assa
4401 Cliq
Scandinavian Oval cylinder (mechatronic)
AZ
Locken
CL-PL2WR
Scandinavian Oval cylinder (mechatronic)
BA
Assa
C5802
Scandinavian Oval double cylinder (key:key)
BB
Abloy
CY404 Disklock Pro (DP)
Screw -in cylinder
11 11
+
+
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES BC
Abloy
CY404 Protec (PT)
Screw -in cylinder
BD
Assa
4851
Screw -in cylinder
BE
Assa
C5851
Screw -in cylinder
BF
Bramah
C17SI
Screw -in cylinder
BG
Kaba
K207.203 C5-SC
Screw -in cylinder
BH
Medico
M3ARX MOTC-1001
Screw -in cylinder
BI
Winkhaus
VS629
Screw -in cylinder
+
+
Accessories
Accessory
Description
Full frame Full frame threshold threshold Low level Low level threshold w ith stop threshold w ith stop Low level Low level threshold threshold Central Tego 200 mm (w ide) by 300 mm (high) vision panel vision panel formed using Tego S46 glazing units located in the centre (w idth) of the leaf at a height betw een 1464.5 and 1614.5 mm up from the bottom of the leaf.
Certificate num ber of associated doorset (234d/##) 01
02
03
04
05
06
07
08
09
10
11
12
13
14
Offset Tego vision panel
200 mm (w ide) by 300 mm (high) vision panel formed using Tego S46 glazing units located betw een the centre of the leaf and leading edge11 at a height betw een 1464.5 and 1614.5 mm up from the bottom of the leaf.
Vistamatic Sherman vision panel12
40.5 mm thick vision panels of maximum dimensions 400 mm by 400 mm. These may either be located central to the w idth of the leaf or offset from leading edge by 150 mm.
Vistamatic Chieftain vision panel12
27.8 mm thick vision panels of maximum dimensions 400 mm by 400 mm. These may either be located central to the w idth of the leaf or offset from leading edge by 150 mm.
20 Nov 2011
373
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES AB26 vision panel
27 mm thick vision panels of maximum dimensions 400 mm by 400 mm. These may either be located central to the w idth of the leaf or offset from leading edge by 150 mm.
Tecdur vision panel
200 mm (w ide) by 300 mm (high) vision panel formed using Tecdur DC49MS glazing units incorporating steel grids located in the centre (w idth) of the leaf at a height betw een 1464.5 and 1614.5 mm from the bottom of the leaf to the centre of the vision panel.
ExcluVent 3 louvre panels
400 mm (w ide) by 400 mm (high) louvre panels located central to the w idth of the leaf in the top half of the leaf, in the bottom half of the leaf, or in both top and bottom half’s of the leaf.
ExcluVent 4 louvre panels
400 mm (w ide) by 400 mm (high) louvre panels located central to the w idth of the leaf in the top half of the leaf, in the bottom half of the leaf, or in both top and bottom half’s of the leaf.
ExcluVent 5 louvre panels
400 mm (w ide) by 400 mm (high) louvre panels located central to the w idth of the leaf in the top half of the leaf, in the bottom half of the leaf, or in both top and bottom half’s of the leaf.
The following table confirms which combinations of vision panel, louvre panel, threshold and locking system may be used together.
Accessory
Com patible locking system s ExecDoor 2 ExcluDoor 4 ExcluDoor 4 ExcluDoor 5 ExcluDoor 4 Mk2 Mk2 F.R. doorset Mk3 doorset doorset and w ith any doorset w ith any ExcluDoor 3 threshold w ith any Mk3 F.R. threshold option 14 threshold doorsets option option Low Level Low Level w ith any Threshold Threshold threshold With Stop option 1 to 53 1 to 11, 13, N/A N/A N/A N/A N/A 16 to 18, 22 to 29, 32 to 42, 44 to 48, 50 to 53
ExcluDoor 3 Mk2 doorset
Full Fram e Threshold ExcluVent 3 louvre panel located in the top half of the leaf
374
1 to 53
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES ExcluVent 3 louvre panel located in the bottom half of the leaf ExcluVent 3 louvre panels located in the top and bottom halves of the leaf ExcluVent 4 louvre panels 15
1 to 53
1 to 53
1 to 53
N/A
N/A
N/A
N/A
N/A
1 to 11, 13, 16 to 18, 22 to 29, 32 to 42, 44 to 48, 50 to 53
1 to 11, 13, 16 to 18, 22 to 29, 32 to 42, 44 to 48, 50 to 53
1 to 11, 13, 16 to 18, 22 to 29, 32 to 42, 44 to 48, 50 to 53
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
52, 53, 63 to 80
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1 to 53
1 to 53
N/A
N/A
N/A
52, 53, 83, 86, 89, 92, 97, 102 N/A
N/A
N/A
1 to 11, 13, 16 to 18, 22 to 29, 32 to 42, 44 to 48, 50 to 53 N/A
52, 53, 83, 86, 89, 92, 97, 102 N/A
54 to 62
N/A
N/A
N/A
N/A
N/A
N/A
N/A
54, 56, 62
N/A
N/A
N/A
N/A
N/A
N/A
N/A
54 to 62
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
52, 53, 63 to 80
N/A
N/A
N/A
ExcluVent 5 louvre panels 15 Central and Offset Tego vision panels
Vistamatic Sherman vision panel Vistamatic Chieftain vision panel AB26 vision panel Tecdur vision panel
Notes: 1. The ExcluDoor 3 Mk2 double leaf doorset can be produced with leafs of unequal width. The maximum width of both leaves is 1173.5 mm. The minimum width of active leaves approved is 615 mm. The minimum width of passive leaves approved is 300 mm (plain leaves) and 500 mm (leaves incorporating vision panels). 2. The ExecDoor 2 double leaf doorsets may incorporate leafs of equal or unequal width. Leafs of unequal width will comprise of an active leaf exactly twice as wide as the passive leaf. The maximum leaf width is 1350 mm and the minimum leaf width is 500 mm. 3. The ExcluDoor 4 Mk2, ExcluDoor 4 Mk2 F.R. and ExcluDoor 3 Mk3 F.R. double leaf doorsets can be produced with leafs of equal and unequal width, with the leaf width being within the following range: a. Active leaf width between 615 mm and 1169.5 mm (excluding the astragal). b. Passive leaf width between 220.5 mm and 1714 mm (excluding the astragal). 4. The ExcluDoor 5 and ExcluDoor 4 Mk3 double leaf doorsets can be produced with leafs of equal and unequal width, with the leaf width being within the following range: a. Active leaf width between 615 mm and 1169.5 mm (excluding the astragal). b. Passive leaf width between 470 mm and 1714 mm (excluding the astragal). 5. Fail secure version only. 6. The resistance of the access control locks to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that Sunray Engineering satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 7. Although outside the scope of LPS 1175: Issue 7, special consideration should be paid to the use of locking systems with separate deadlocks, e.g. Mico 942-3 INT MD. This is because it is generally not acceptable to separately deadlock a doorset that is fitted with a panic or emergency exit device unless the deadlock is automatically operated by the action of the panic or exit device. For further information, please refer to the appropriate standards for emergency and panic exit devices, i.e. BS EN 179 and BS EN 1125 respectively. 8. Locking systems 58, 59 and 60 may not comply with fire escape regulations relating to potential panic situations if fitted to double leaf doorsets. This is because activation of the device on one leaf may not necessarily release the other leaf and in some cases may not release the leaf to which it is fitted. 9. This locking system may only be used on the passive leaf and then only if locking systems 58, 59 and 60 are used on the active leaf. 10. A ‘Plus’ rating demonstrates that the cylinder meets the requirements defined in Annex A of BS 3621: 2007 or manipulation resistance class ‘1’ defined in LPS 1242: Issue 2. 11. The resistance of the mechatronic cylinders to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of
20 Nov 2011
375
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
12. 13. 14.
15.
ancillary equipment that may be used in conjunction with those cylinders. It is therefore recommended that specifiers satisfy themselves that the components used are either resistant to electronic methods of attack, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. The horizontal position of the offset vision panels depends on the locking hardware fitted. Please refer to the manufacturer for more details. The Vistamatic vision panels incorporate obscurable panels controlled by a handle on the protected side of the doorset. The ExcluDoor 5 double leaf doorsets incorporating ExcluVent 5 louvre panels achieve Security Rating 4 when placed in the minimum locked condition and incorporating locking systems 92, 97 and 102 on the active leaf and locking system 52 on the passive leaf. All other ExcluDoor 5 double leaf doorsets incorporating ExcluVent 5 louvre panels achieve Security Rating 5 when placed in the minimum locked condition. The ExcluVent 4 and ExcluVent 5 louvre panels were compatible with the locking options listed when the louvre panels were located in the top half of the leaf only, the bottom half of the leaf only, or in both the top and bottom halves of the leaf.
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Certificate No: 450a to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
UltraSecure DS1/DV4
Single leaf hinged outward opening security doorset Double leaf hinged outward opening security doorset
UltraSecure DS2/DV4
Minimum Clear Opening Height (m) 0.9
Maximum Clear Opening Height (m) 2.9
Minimum Clear Opening Width (m) 0.5
Maximum Clear Opening Width (m) 1.3
Security Rating
Cert. No.
4
450a/03
0.9
2.9
1.2
2.6
4
450a/08
Compatible Locks
Padlock Designation
Cylinder
Abloy PL240/25 Abloy PL240/25EX Abloy PL240/25DP Abloy PL240/25PT Abloy PL242 Abloy PL242EX Abloy PL242DP Abloy PL242PT Abloy PL250/25 Abloy PL250/25EX Abloy PL250/25DP Abloy PL250/25 Abloy PL250/25 Abloy PL250/25EX
Abloy High profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy High Profile Abloy High Profile Abloy Exec
376
UltraSecure Doorset (LPCB Ref. No. 450a/……) 03
08
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Abloy PL250/25DP Abloy PL250/25PT Abloy PL340 Abloy PL340EX Abloy PL340DP Abloy PL340PT Abloy PL342 Abloy PL342EX Abloy PL342DP Abloy PL342PT Abloy PL350/25 Abloy PL350/25EX Abloy PL350/25DP Abloy PL350/25PT Chubb 1K23c Kaba KP15.0000C5-RB Kaba K20SS65L Kaba K20SS65CL Kaba Thorlock4 Rotalok 60/12/SE Rotalok 60/12/SE Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST-T027 Rotalok 60/12/ST Rotalok 60/12/ST
Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Chubb 6-pin cylinder Kaba 20 (Armoured)3 Kaba 20 (Armoured)3 Kaba 20 (Armoured)3 Kaba 20 Kaba 20 (Armoured)3 Kaba 20 (Standard)3 Abloy Disklock Pro Abloy Exec Abloy Protec Assa Twin-Combi Kaba 20 (Armoured)3 Kaba 20 (Standard)3
Accessories
Accessory
UltraSecure Doorset (LPCB Ref. No. 450a/……)
Arched profile K1 staple4 Louver option 1 Louver option 2 Narrow frame Shallow threshold
03
08
Notes 1. 2. 3. 4. 5.
Certification does not cover the use of padlocks other than those listed above. Utilisation of unlisted padlocks and/or accessories may affect the level of security offered by the door set. The ‘user friendliness’ of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS 1175: Issue 5. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders. K1 staple is used in conjunction with the Kaba Thorlock fitted with a Kaba 20 cylinder. The use of the locking override system is outside the scope of the LPCB approval.
Certificate No: 450d to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
Ultra Secure DS1/DV3
Single leaf hinged outward opening security doorset
20 Nov 2011
Minimum Clear Opening Height (m) 0.9
Maximum Clear Opening Height (m) 2.9
Maximum Clear Opening Width (m) 0.5
Maximum Clear Opening Width (m) 1.3
Security Rating
Cert. No.
3
450d/01
377
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Product Name
Type
Ultra Secure DS1/LS3
Single leaf hinged outward opening security doorset Double leaf hinged outward opening security doorset
Ultra Secure DS2/DV3
Minimum Clear Opening Height (m) 0.9
Maximum Clear Opening Height (m) 2.3
Maximum Clear Opening Width (m) 0.5
Maximum Clear Opening Width (m) 1.1
Security Rating
Cert. No.
3
450d/02
0.9
2.9
1.2
2.6
3
450d/03
Compatible locking devices
Locking Device
Type
Cylinder
Abloy PL240/25 Abloy PL240/25EX Abloy PL240/25DP Abloy PL240/25PT Abloy PL242 Abloy PL242EX Abloy PL242DP Abloy PL242PT Abloy PL250/25 Abloy PL250/25EX Abloy PL250/25DP Abloy PL250/25PT Abloy PL340 Abloy PL340EX Abloy PL340DP Abloy PL340PT Abloy PL342 Abloy PL342EX Abloy PL342DP Abloy PL342PT Abloy PL350/25 Abloy PL350/25EX Abloy PL350/25DP Abloy PL350/25PT Chubb 1K23c Kaba KP15.0000C5-RB Kaba K20SS65L
Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock
Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Chubb 6-pin cylinder Kaba 20 (Armoured)3 Kaba 20 (Armoured)3
378
Ultra Secure Doorsets (LPCB Ref. No. 450d/..) 01 02 03
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Kaba K20SS65CL Kaba Thorlock4 Kaba Thorlock4 Rotalok 60/12/SE Rotalok 60/12/SE Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST-T027 Rotalok 60/12/ST Rotalok 60/12/ST Surelock McGill DL800
Padlock Integral lock Integral lock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock Single point surface mounted locking device with cylinder deadlock operated by key (outside) and turn knob (inside) with integrated S-10319 cylinder guard
Kaba 20 (Armoured)3 Kaba 20 (Armoured)3 Kaba 20 (Standard)3 Kaba 20 (Armoured)3 Kaba 20 (Standard)3 Abloy Disklock Pro Abloy Exec Abloy Protec Assa Twin-Combi Kaba 20 (Armoured)3 Kaba 20 (Standard)3 ASSA Flexicore F523
Surelock McGill DL800
Single point surface ASSA 4823 mounted locking device with cylinder deadlock operated by key (outside) and turn knob (inside) with integrated S-10319 cylinder guard
Surelock McGill DL800
Single point surface ASSA Twin Combi mounted locking F5823 device with cylinder deadlock operated by key (outside) and turn knob (inside) with integrated S-10319 cylinder guard
Surelock McGill DL800
Single point surface Abloy Disklok Pro mounted locking CY303 device with cylinder deadlock operated by key (outside) and turn knob (inside) with integrated S-10319 cylinder guard
20 Nov 2011
379
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Surelock McGill DL800
Single point surface Kaba QS152.100.00 mounted locking device with cylinder deadlock operated by key (outside) and turn knob (inside) with integrated S-10319 cylinder guard
Surelock McGill DL800
Single point surface Union 2X20A mounted locking device with cylinder deadlock operated by key (outside) and turn knob (inside) with integrated S-10319 cylinder guard
Notes 1.
Certification does not cover the use of locks other than those listed above. Utilisation of unlisted locks may affect the level of security offered by the door set. The ‘user friendliness’ of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS 1175: Issue 5. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders. Certification only covers the galvanised mild steel versions.
2. 3. 4.
Certificate No: 450f to LPS 1175: Issue 7
Hinged Security Doorsets Product Name
Doorset Configuration
Sentinel UltraSecure
Single leaf outward opening hinged security doorset Double1 leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Double1 leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Double1 leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset
380
Minimum Structural Opening Height (m) 1.8
Maximum Structural Opening Height (m) 2.35
Minimum Structural Opening Width (m) 0.75
Maximum Structural Opening Width (m) 1.2
Security Rating
Cert. No.
3
450f/01
1.8
2.35
1.2
2.185
32
450f/02
1.8
2.35
0.75
1.2
4
450f/03
1.8
2.35
1.2
2.185
4
450f/04
1.8
2.35
0.75
1.2
5
450f/05
1.8
2.35
1.2
2.3
5
450f/06
1.7
2.35
0.75
1.2
3
450f/07
1.7
2.35
1.2
2.35
32
450f/08
1.7
2.35
0.75
1.2
4
450f/09
1.7
2.35
1.2
2.35
4
450f/10
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES Approved Locking Configurations
LPCB Ref. Trade Name No. 450f/01 Sentinel UltraSecure 450f/02 Sentinel UltraSecure 450f/03 Sentinel UltraSecure 450f/04 Sentinel UltraSecure 450f/05 Sentinel UltraSecure 450f/06 Sentinel UltraSecure 450f/07 450f/08 450f/09 450f/10
Sentinel UltraSecure Sentinel UltraSecure Sentinel UltraSecure Sentinel UltraSecure
Type
Compatible Locking Systems
Single leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Double1 leaf outward opening hinged security doorset
SM1 to SM5, SM11 to SM15 and SM21 to SM25 SM1 to SM5, SM11 to SM15 and SM21 to SM25 SM6 to SM10, SM16 to SM20 and SM26 to SM30 SM6 to SM10, SM16 to SM20 and SM26 to SM30 MT21 to MT30, MT51 to MT60 and MT81 to MT90 MT22, MT24, MT26, MT28, MT30, MT52, MT54, MT56, MT58, MT60, MT82, MT84, MT86, MT88, MT90 MT1 to MT10, MT31 to MT40 and MT61 to MT70 MT1(T) to MT10(T), MT31(T) to MT40(T) and MT61(T) to MT70(T) MT11 to MT20, MT41 to MT50 and MT71 to MT80 MT12(T), MT14(T), MT16(T), MT18(T), MT20(T), MT42(T), MT44(T), MT46(T), MT48(T), MT50(T), MT72(T), MT74(T), MT76(T), MT78(T), MT80(T)
Single leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset
Compatible Locking Systems Compatible Locking System
Manufacturer
Passive Leaf
Compatible Cylinders
Model
External Face
Internal Face
SM1
Surelock McGill Limited
EX800-K2-Q4-P(04/05) single point emergency exit device
Key and lever handle
Single action lever handle
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM2
Surelock McGill Limited
DL800-Q4-P(04/05) single point lock
Key and lever handle
Thumb turn and lever handle
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM3
Surelock McGill Limited
SL315-H3-P-A5(04/05) three point emergency exit device
Key and lever handle
Single action push pad
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM4
Surelock McGill Limited
SL314-P-A5(04/05) three point panic exit device
Key and lever handle
Panic bar
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM5
Surelock McGill Limited
Two S3TB barrel AC800-K2-K4-P-RElectroElectrobolts (04/05) single mechanical mechanical access control access control point lock3 lock (fail secure) lock with break with key override dome thumb turn override and and lever handle lever handle
AH, AM, AN, AO, AP
SM6
Surelock McGill Limited
SL315-P5-A5(04/05) three point emergency exit device
20 Nov 2011
Operating Devices Active Leaf
Key and lever handle
Single action lever handle
Two S3TB barrel bolts
AH, AM, AN, AO, AP
381
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
382
SM7
Surelock McGill Limited
SL313-P5-A5-K15(04/05) three point locking system
Key and lever handle
Thumb turn and lever handle
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM8
Surelock McGill Limited
SL315-H3-P5-A5(04/05) three point emergency exit device
Key and lever handle
Single action push pad
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM9
Surelock McGill Limited
SL314-P5-A5(04/05) three point panic exit device
Key and lever handle
Panic bar
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM10
Surelock McGill Limited
SL322-P5-A5-K2K4-(04/05) three point locking system 3
ElectroTwo S3TB barrel Electromechanical bolts mechanical access control access control lock (fail secure) lock with break with key override dome thumb turn and lever handle override and lever handle
AH, AM, AN, AO, AP
SM11
Surelock McGill Limited
AC800-K2-P-Q4-RElectromechanical X-(04/05) single access control point emergency lock (fail secure) exit device3 with key override and lever handle
Single action lever handle
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM12
Surelock McGill Limited
Thumb turn and lever handle
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM13
Surelock McGill Limited
SL325-H3-P-K2Electromechanical A5-R-(04/05) three access control point emergency lock (fail secure) exit device 3 with key override and lever handle
Single action push pad
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM14
Surelock McGill Limited
SL324-P-A5-K2-R(04/05) three point panic exit device 3
Panic bar
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM15
Surelock McGill Limited
ElectroTwo S3TB barrel AC800-K2-K4-P-RElectromechanical bolts mechanical (04/05) single access control access control point lock3 lock (fail secure) lock with break with key override dome thumb turn and lever handle override and lever handle
AH, AM, AN, AO, AP
AC800-K2-K9-PQ4-R-(04/05) single point lock3
Electromechanical access control lock (fail secure) with key override and lever handle
Electromechanical access control lock (fail secure) with key override and lever handle
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES SM16
Surelock McGill Limited
SL325-P5-K2-A5R-(04/05) three point emergency exit device3
SM17
Surelock McGill Limited
SM18
Electromechanical access control lock (fail secure) with key override and lever handle
Single action lever handle
Two S3TB barrel bolts
AH, AM, AN, AO, AP
ElectroSL323-P5-K2-K15A5-R-(04/05) three mechanical point locking access control lock (fail secure) system3 with key override and lever handle
Thumb turn and lever handle
Two S3TB barrel bolts
AH, AM, AN, AO, AP
Surelock McGill Limited
ElectroSL325-H3-P5-K2A5-R-(04/05) three mechanical point emergency access control lock (fail secure) exit device3 with key override and lever handle
Single action push pad
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM19
Surelock McGill Limited
SL324-P5-A5-K2R-(04/05) three point panic exit device3
Electromechanical access control lock (fail secure) with key override and lever handle
Panic bar
Two S3TB barrel bolts
AH, AM, AN, AO, AP
SM20
Surelock McGill Limited
SL322-P5-A5-K2K4-(04/05) three point locking system 3
ElectroTwo S3TB barrel Electromechanical bolts mechanical access control access control lock (fail secure) lock with break with key override dome thumb turn override and and lever handle lever handle
AH, AM, AN, AO, AP
SM21
Surelock McGill Limited
EX800-Q4-(04/05) single point emergency exit device
None
Single action lever handle
Two S3TB barrel bolts
Not applicable
SM22
Surelock McGill Limited
DL800-Q4-(04/05) single point lock
None
Thumb turn and lever handle
Two S3TB barrel bolts
Not applicable
SM23
Surelock McGill Limited
SL315-H3-A5(04/05) three point emergency exit device
None
Single action push pad
Two S3TB barrel bolts
Not applicable
SM24
Surelock McGill Limited
SL314-A5-(04/05) three point panic exit device
None
Panic bar
Two S3TB barrel bolts
Not applicable
20 Nov 2011
383
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
384
SM25
Surelock McGill Limited
AC800-K4-R(04/05) single point lock3
None
ElectroTwo S3TB barrel mechanical bolts access control lock (fail secure) with break dome thumb turn override and lever handle
SM26
Surelock McGill Limited
SL315-A5-(04/05) three point emergency exit device
None
Single action lever handle
Two S3TB barrel bolts
Not applicable
SM27
Surelock McGill Limited
SL313-O0-A5-K15(04/05) three point locking system
None
Thumb turn and lever handle
Two S3TB barrel bolts
Not applicable
SM28
Surelock McGill Limited
SL315-H3-A5(04/05) three point emergency exit device
None
Single action push pad
Two S3TB barrel bolts
Not applicable
SM29
Surelock McGill Limited
SL314-A5-(04/05) three point panic exit device
None
Panic bar
Two S3TB barrel bolts
Not applicable
SM30
Surelock McGill Limited
SL322-A5-K4(04/05) three point locking system3
None
ElectroTwo S3TB barrel mechanical bolts access control lock (fail secure) with break dome thumb turn override and lever handle
Not applicable
MT1
Tindall Engineering Limited
Abryll AD 4 SATE USCH3 single point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
A to M and AH to AN
MT1
Tindall Engineering Limited
Abryll AD 4 SATE EPC USCH3 single point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT1(T)
Tindall Engineering Limited
Abryll AD 4 SATE USCH3 single point emergency exit device
Key and lever handle
Single action lever handle
Two HSTB barrel bolts
A to M and AH to AN
Not applicable
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT1(T)
Tindall Engineering Limited
Abryll AD 4 SATE EPC USCH3 single point emergency exit device
Key and lever handle
Single action lever handle
MT2
Tindall Engineering Limited
942-3L INT AD SATE USCH3three point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
A to M and AH to AN
MT2
Tindall Engineering Limited
942-3L INT AD SATE EPC USCH3 three point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT2(T)
Tindall Engineering Limited
942-3L INT AD SATE USCH3 three point emergency exit device
Key and lever handle
Single action lever handle
Two HSTB barrel bolts
A to M and AH to AN
MT2(T)
Tindall Engineering Limited
942-3L INT AD SATE EPC USCH3 three point emergency exit device
Key and lever handle
Single action lever handle
Two HSTB barrel N, Q, T, V, X, Z, bolts AB, AD, AF
MT3
Tindall Engineering Limited
Abryll AD 3 USCH3 single point lock
Key and lever handle
Thumb turn and lever handle
Not applicable
A to M and AH to AN
MT3
Tindall Engineering Limited
Abryll AD 3 EPC USCH3 single point lock
Key and lever handle
Thumb turn and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT3(T)
Tindall Engineering Limited
Abryll AD 3 USCH3 single point lock
Key and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
A to M and AH to AN
MT3(T)
Tindall Engineering Limited
Abryll AD 3 EPC USCH3 single point lock
Key and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT4
Tindall Engineering Limited
942-3L INT AD USCH3 three point locking system
Key and lever handle
Thumb turn and lever handle
Not applicable
A to M and AH to AN
MT4
Tindall Engineering Limited
942-3L INT AD EPC USCH3 three point locking system
Key and lever handle
Thumb turn and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT4(T)
Tindall Engineering Limited
942-3L INT AD USCH3 three point locking system
Key and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
20 Nov 2011
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
A to M and AH to AN
385
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
386
MT4(T)
Tindall Engineering Limited
942-3L INT AD EPC USCH3 three point locking system
Key and lever handle
MT5
Tindall Engineering Limited
Abryll AD 1 SATE USCH3 single point emergency exit device
Key and lever handle
Single action push pad
Not applicable
A to M and AH to AN
MT5
Tindall Engineering Limited
Abryll AD 1 SATE EPC USCH3 single point emergency exit device
Key and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT5(T)
Tindall Engineering Limited
Abryll AD 1 SATE USCH3 single point emergency exit device
Key and lever handle
Single action push pad
Two HSTB barrel A to M And AH bolts to AN
MT5(T)
Tindall Engineering Limited
Abryll AD 1 SATE EPC USCH3 single point emergency exit device
Key and lever handle
Single action push pad
Two HSTB barrel N, Q, T, V, X, Z, bolts AB, AD, AF
MT6
Tindall Engineering Limited
942-3P INT AD SATE USCH3 three point emergency exit device
Key and lever handle
Single action push pad
Not applicable
A to M and AH to AN
MT6
Tindall Engineering Limited
942-3P INT AD SATE EPC USCH3three point emergency exit device
Key and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT6(T)
Tindall Engineering Limited
942-3P INT AD SATE USCH3three point emergency exit device
Key and lever handle
Single action push pad
Two HSTB barrel bolts
A to M and AH to AN
MT6(T)
Tindall Engineering Limited
942-3P INT AD SATE EPC USCH3 three point emergency exit device
Key and lever handle
Single action push pad
Two HSTB barrel N, Q, T, V, X, Z, bolts AB, AD, AF
MT7
Tindall Engineering Limited
Abryll AD 2 SATE USCH3 single point panic exit device
Key and lever handle
Panic bar
Not applicable
A to M and AH to AN
MT7
Tindall Engineering Limited
Abryll AD 2 SATE EPC USCH3 single point panic exit device
Key and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT7(T)
Tindall Engineering Limited
Abryll AD 2 SATE USCH3 single point panic exit device
Key and lever handle
Panic bar
Two HSTB barrel bolts
A to M and AH to AN
Thumb turn and Two HSTB barrel lever handle bolts
O, P, R, S, U, W, Y, AA, AC, AE, AG
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT7(T)
Tindall Engineering Limited
Abryll AD 2 SATE EPC USCH3 single point panic exit device
Key and lever handle
Panic bar
MT8
Tindall Engineering Limited
942-3 INT AD SATE USCH3 three point panic exit device
Key and lever handle
Panic bar
Not applicable
A to M and AH to AN
MT8
Tindall Engineering Limited
942-3 INT AD SATE EPC USCH3 three point panic exit device
Key and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT8(T)
Tindall Engineering Limited
942-3 INT AD SATE USCH3 three point panic exit device
Key and lever handle
Panic bar
Two HSTB barrel bolts
A to M and AH to AN
MT8(T)
Tindall Engineering Limited
942-3 INT AD SATE EPC USCH3 three point panic exit device
Key and lever handle
Panic bar
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT9
Tindall Engineering Limited
Abryll EM 1 (fail secure) USCH3 single point lock3
Key and lever handle
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
A to M and AH to AN
MT9
Tindall Engineering Limited
Abryll EM 1 (fail secure) EPC USCH3 single point lock3
Key and lever handle
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT9(T)
Tindall Engineering Limited
Abryll EM 1 (fail secure) USCH3 single point lock3
Key and lever handle
Two HSTB barrel Electrobolts mechanical access control lock with shrouded thumb turn override and lever handle
A to M and AH to AN
MT9(T)
Tindall Engineering Limited
Abryll EM 1 (fail secure) EPC USCH3 single point lock3
Key and lever handle
Two HSTB barrel Electrobolts mechanical access control lock with shrouded thumb turn override and lever handle
O, P, R, S, U, W, Y, AA, AC, AE, AG
20 Nov 2011
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
387
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
388
MT10
Tindall Engineering Limited
942-3L EM (fail secure) USCH3 three point locking system 3
Key and lever handle
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
A to M and AH to AN
MT10
Tindall Engineering Limited
942-3L EM (fail secure) EPC USCH3 three point locking system3
Key and lever handle
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT10(T)
Tindall Engineering Limited
942-3L EM (fail secure) USCH3 three point locking system 3
Key and lever handle
Two HSTB barrel Electrobolts mechanical access control lock with shrouded thumb turn override and lever handle
A to M and AH to AN
MT10(T)
Tindall Engineering Limited
942-3L EM (fail secure) EPC USCH3 three point locking system3
Key and lever handle
ElectroTwo HSTB barrel mechanical bolts access control lock with shrouded thumb turn override and lever handle
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT11
Tindall Engineering Limited
Abryll AD 4 SATE USCH4 single point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
B to M and AH to AN
MT11
Tindall Engineering Limited
Abryll AD 4 SATE EPC USCH4 single point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT12
Tindall Engineering Limited
942-3L INT AD SATE USCH4 three point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
B to M and AH to AN
MT12
Tindall Engineering Limited
942-3L INT AD SATE EPC USCH4 three point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT12(T)
Tindall Engineering Limited
942-3L INT AD SATE USCH4 three point emergency exit device
Key and lever handle
Single action lever handle
Two HSTB barrel bolts
B to M and AH to AN
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT12(T)
Tindall Engineering Limited
942-3L INT AD SATE EPC USCH4 three point emergency exit device
Key and lever handle
Single action lever handle
MT13
Tindall Engineering Limited
Abryll AD 3 SATE USCH4 single point lock
Key and lever handle
Thumb turn and lever handle
Not applicable
B to M and AH to AN
MT13
Tindall Engineering Limited
Abryll AD 3 SATE EPC USCH4 single point lock
Key and lever handle
Thumb turn and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT14
Tindall Engineering Limited
942-3L INT AD USCH4 three point locking system
Key and lever handle
Thumb turn and lever handle
Not applicable
B to M and AH to AN
MT14
Tindall Engineering Limited
942-3L INT AD EPC USCH4 three point locking system
Key and lever handle
Thumb turn and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT14(T)
Tindall Engineering Limited
942-3L INT AD USCH4 three point locking system
Key and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
B to M and AH to AN
MT14(T)
Tindall Engineering Limited
942-3L INT AD EPC USCH4 three point locking system
Key and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT15
Tindall Engineering Limited
Abryll AD 1 SATE USCH4 single point emergency exit device
Key and lever handle
Single action push pad
Not applicable
B to M and AH to AN
MT15
Tindall Engineering Limited
Abryll AD 1 SATE EPC USCH4 single point emergency exit device
Key and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT16
Tindall Engineering Limited
942-3P INT AD SATE USCH4 three point emergency exit device
Key and lever handle
Single action push pad
Not applicable
B to M and AH to AN
MT16
Tindall Engineering Limited
942-3P INT AD SATE EPC USCH4 three point emergency exit device
Key and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT16(T)
Tindall Engineering Limited
942-3P INT AD SATE USCH4 three point emergency exit device
Key and lever handle
Single action push pad
Two HSTB barrel bolts
B to M and AH to AN
20 Nov 2011
Two HSTB barrel N, Q, T, V, X, Z, bolts AB, AD, AF
389
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
390
MT16(T)
Tindall Engineering Limited
942-3P INT AD SATE EPC USCH4 three point emergency exit device
Key and lever handle
Single action push pad
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT17
Tindall Engineering Limited
Abryll AD 2 SATE USCH4 single point panic exit device
Key and lever handle
Panic bar
Not applicable
B to M and AH to AN
MT17
Tindall Engineering Limited
Abryll AD 2 SATE EPC USCH4 single point panic exit device
Key and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT18
Tindall Engineering Limited
942-3 INT AD SATE USCH4 three point panic exit device
Key and lever handle
Panic bar
Not applicable
B to M and AH to AN
MT18
Tindall Engineering Limited
942-3 INT AD SATE EPC USCH4 three point panic exit device
Key and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT18(T)
Tindall Engineering Limited
942-3 INT AD SATE USCH4 three point panic exit device
Key and lever handle
Panic bar
Two HSTB barrel bolts
B to M and AH to AN
MT18(T)
Tindall Engineering Limited
942-3 INT AD SATE EPC USCH4 three point panic exit device
Key and lever handle
Panic bar
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT19
Tindall Engineering Limited
Abryll EM 1 (fail secure) USCH4 single point lock3
Key and lever handle
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
B to M and AH to AN
MT19
Tindall Engineering Limited
Abryll EM 1 (fail secure) EPC USCH4 single point lock3
Key and lever handle
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT20
Tindall Engineering Limited
942-3L EM (fail secure) USCH4 three point locking system 3
Key and lever handle
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
B to M and AH to AN
MT20
Tindall Engineering Limited
942-3L EM (fail secure) EPC USCH4 three point locking system3
Key and lever handle
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT20(T)
Tindall Engineering Limited
942-3L EM (fail secure) USCH4 three point locking system 3
Key and lever handle
Two HSTB barrel Electrobolts mechanical access control lock with shrouded thumb turn override and lever handle
B to M and AH to AN
MT20(T)
Tindall Engineering Limited
942-3L EM (fail secure) EPC USCH4 three point locking system3
Key and lever handle
ElectroTwo HSTB barrel mechanical bolts access control lock with shrouded thumb turn override and lever handle
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT21
Tindall Engineering Limited
Abryll AD3 SATE USCH5 single point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
B to M and AH to AN
MT21
Tindall Engineering Limited
Abryll AD3 SATE EPC USCH5 single point emergency exit device
Key and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT22
Tindall Engineering Limited
942L INT AD SATE USCH5 three point emergency exit device
Key and lever handle
Single action lever handle
Two HSTB barrel bolts
B to M and AH to AN
MT22
Tindall Engineering Limited
942L INT AD SATE EPC USCH5 three point emergency exit device
Key and lever handle
Single action lever handle
Two HSTB barrel N, Q, T, V, X, Z, bolts AB, AD, AF
MT23
Tindall Engineering Limited
Abryll AD3 USCH5 single point lock
Key and lever handle
Thumb turn and lever handle
20 Nov 2011
Not applicable
B to M and AH to AN
391
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
392
MT23
Tindall Engineering Limited
Abryll AD3 EPC USCH5 single point lock
Key and lever handle
Thumb turn and lever handle
MT24
Tindall Engineering Limited
942L INT AD USCH5 three point locking system
Key and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
B to M and AH to AN
MT24
Tindall Engineering Limited
942L INT AD EPC USCH5 three point locking system
Key and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT25
Tindall Engineering Limited
Abryll AD1 SATE USCH5 single point emergency exit device
Key and lever handle
Single action push pad
Not applicable
B to M and AH to AN
MT25
Tindall Engineering Limited
Abryll AD1 SATE EPC USCH5 single point emergency exit device
Key and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT26
Tindall Engineering Limited
942P INT AD SATE USCH5 three point emergency exit device
Key and lever handle
Single action push pad
Two HSTB barrel bolts
B to M and AH to AN
MT26
Tindall Engineering Limited
942P INT AD SATE EPC USCH5 three point emergency exit device
Key and lever handle
Single action push pad
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT27
Tindall Engineering Limited
Abryll AD2 SATE USCH5 single point panic exit device
Key and lever handle
Panic bar
Not applicable
B to M and AH to AN
MT27
Tindall Engineering Limited
Abryll AD2 SATE EPC USCH5 single point panic exit device
Key and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT28
Tindall Engineering Limited
942 INT AD SATE USCH5 three point panic exit device
Key and lever handle
Panic bar
Two HSTB barrel bolts
B to M and AH to AN
MT28
Tindall Engineering Limited
942 INT AD SATE EPC USCH5 three point panic exit device
Key and lever handle
Panic bar
Two HSTB barrel N, Q, T, V, X, Z, bolts AB, AD, AF
MT29
Tindall Engineering Limited
Abryll EM3 (fail secure) USCH5 single point lock3
ElectroElectromechanical mechanical access control access control lock (fail secure) lock with thumb with key override turn override and lever handle and lever handle
Not applicable
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
B to M and AH to AN
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES O, P, R, S, U, W, Y, AA, AC, AE, AG
Tindall Engineering Limited
MT30
Tindall Engineering Limited
Two HSTB barrel ElectroElectro942L EM bolts mechanical mechanical (fail secure) USCH5 three point access control access control lock (fail secure) lock with thumb locking system3 with key override turn override and lever handle and lever handle
B to M and AH to AN
MT30
Tindall Engineering Limited
Two HSTB barrel Electro942L EM Electrobolts mechanical (fail secure) EPC mechanical USCH5 three point access control access control lock (fail secure) lock with thumb locking system3 with key override turn override and lever handle and lever handle
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT31
Tindall Engineering Limited
Abryll EM 4 SATE Electro(fail secure) mechanical USCH3 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action lever handle
Not applicable
A to M and AH to AN
MT31
Tindall Engineering Limited
Abryll EM 4 SATE Electro(fail secure) EPC mechanical USCH3 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT31(T)
Tindall Engineering Limited
Abryll EM 4 SATE Electro(fail secure) mechanical USCH3 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action lever handle
Two HSTB barrel bolts
A to M and AH to AN
20 Nov 2011
Abryll EM3 (fail secure) EPC USCH5 single point lock3
ElectroElectromechanical mechanical access control access control lock (fail secure) lock with thumb with key override turn override and lever handle and lever handle
Not applicable
MT29
393
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
394
MT31(T)
Tindall Engineering Limited
Abryll EM 4 SATE Electro(fail secure) EPC mechanical USCH3 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action lever handle
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT32
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) USCH3 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action lever handle
Not applicable
A to M and AH to AN
MT32
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) EPC USCH3 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT32(T)
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) USCH3 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action lever handle
Two HSTB barrel bolts
A to M and AH to AN
MT32(T)
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) EPC USCH3 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action lever handle
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT33
Tindall Engineering Limited
Abryll EM 3 SATE Electro(fail secure) mechanical USCH3 single access control lock (fail secure) point lock3 with key override and lever handle
Thumb turn and lever handle
Not applicable
A to M and AH to AN
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT33
Tindall Engineering Limited
Abryll EM 3 SATE Electro(fail secure) EPC mechanical USCH3 single access control lock (fail secure) point lock3 with key override and lever handle
Thumb turn and lever handle
MT33(T)
Tindall Engineering Limited
Abryll EM 3 SATE Electro(fail secure) mechanical USCH3 single access control lock (fail secure) point lock3 with key override and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
A to M and AH to AN
MT33(T)
Tindall Engineering Limited
Abryll EM 3 SATE Electro(fail secure) EPC mechanical USCH3 single access control lock (fail secure) point lock3 with key override and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT34
Tindall Engineering Limited
Electro942-3L EM mechanical (fail secure) USCH3 three point access control lock (fail secure) locking system3 with key override and lever handle
Thumb turn and lever handle
Not applicable
A to M and AH to AN
MT34
Tindall Engineering Limited
Electro942-3L EM mechanical (fail secure) EPC USCH3 three point access control lock (fail secure) locking system3 with key override and lever handle
Thumb turn and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT34(T)
Tindall Engineering Limited
Electro942-3L EM mechanical (fail secure) USCH3 three point access control lock (fail secure) locking system3 with key override and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
20 Nov 2011
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
A to M and AH to AN
395
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
396
MT34(T)
Tindall Engineering Limited
Electro942-3L EM mechanical (fail secure) EPC USCH3 three point access control lock (fail secure) locking system3 with key override and lever handle
MT35
Tindall Engineering Limited
Abryll EM 1 SATE Electro(fail secure) mechanical USCH3 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action push pad
Not applicable
A to M and AH to AN
MT35
Tindall Engineering Limited
Abryll EM 1 SATE Electro(fail secure) EPC mechanical USCH3 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT35(T)
Tindall Engineering Limited
Abryll EM 1 SATE Electro(fail secure) mechanical USCH3 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action push pad
Two HSTB barrel bolts
A to M and AH to AN
MT35(T)
Tindall Engineering Limited
Abryll EM 1 SATE Electro(fail secure) EPC mechanical USCH3 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action push pad
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT36
Tindall Engineering Limited
Electro942-3P EM SATE mechanical (fail secure) USCH3 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
Thumb turn and Two HSTB barrel lever handle bolts
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
A to M and AH to AN
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT36
Tindall Engineering Limited
Electro942-3P EM SATE mechanical (fail secure) EPC USCH3 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT36(T)
Tindall Engineering Limited
Electro942-3P EM SATE mechanical (fail secure) USCH3 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
Two HSTB barrel bolts
A to M and AH to AN
MT36(T)
Tindall Engineering Limited
Electro942-3P EM SATE mechanical (fail secure) EPC USCH3 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT37
Tindall Engineering Limited
Abryll EM 2 SATE Electro(fail secure) mechanical USCH3 single access control point panic exit lock (fail secure) with key override device3 and lever handle
Panic bar
Not applicable
A to M and AH to AN
MT37
Tindall Engineering Limited
Abryll EM 2 SATE Electro(fail secure) EPC mechanical USCH3 single access control point panic exit lock (fail secure) with key override device3 and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT37(T)
Tindall Engineering Limited
Abryll EM 2 SATE Electro(fail secure) mechanical USCH3 single access control point panic exit lock (fail secure) with key override device3 and lever handle
Panic bar
Two HSTB barrel bolts
A to M and AH to AN
20 Nov 2011
397
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
398
MT37(T)
Tindall Engineering Limited
Abryll EM 2 SATE Electro(fail secure) EPC mechanical USCH3 single access control point panic exit lock (fail secure) with key override device3 and lever handle
Panic bar
MT38
Tindall Engineering Limited
Electro942-3 EM SATE mechanical (fail secure) USCH3 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Not applicable
A to M and AH to AN
MT38
Tindall Engineering Limited
Electro942-3 EM SATE mechanical (fail secure) EPC USCH3 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT38(T)
Tindall Engineering Limited
942-3 EM SATE Electro(fail secure) mechanical USCH3 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Two HSTB barrel bolts
A to M and AH to AN
MT38(T)
Tindall Engineering Limited
942-3 EM SATE Electro(fail secure) EPC mechanical USCH3 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Two HSTB barrel N, Q, T, V, X, Z, bolts AB, AD, AF
MT39
Tindall Engineering Limited
Abryll EM 1 (fail secure) USCH3 single point lock3
ElectroElectromechanical mechanical access control access control lock with lock (fail secure) with key override shrouded thumb and lever handle turn override and lever handle
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
Not applicable
A to M and AH to AN
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES ElectroElectromechanical mechanical access control access control lock with lock (fail secure) with key override shrouded thumb and lever handle turn override and lever handle
MT39
Tindall Engineering Limited
Abryll EM 1 (fail secure) EPC USCH3 single point lock3
MT39(T)
Tindall Engineering Limited
Abryll EM 1 (fail secure) USCH3 single point lock3
ElectroTwo HSTB barrel Electromechanical bolts mechanical access control access control lock with lock (fail secure) with key override shrouded thumb and lever handle turn override and lever handle
A to M and AH to AN
MT39(T)
Tindall Engineering Limited
Abryll EM 1 (fail secure)EPC USCH3 single point lock3
ElectroTwo HSTB barrel Electromechanical bolts mechanical access control access control lock with lock (fail secure) with key override shrouded thumb and lever handle turn override and lever handle
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT40
Tindall Engineering Limited
Electro942-3L EM (fail Electromechanical secure) USCH3 mechanical access control three point locking access control lock with lock (fail secure) system 3 with key override shrouded thumb and lever handle turn override and lever handle
Not applicable
A to M and AH to AN
MT40
Tindall Engineering Limited
Electro942-3L EM (fail Electromechanical secure) EPC mechanical access control USCH3 three point access control lock with lock (fail secure) locking system3 with key override shrouded thumb and lever handle turn override and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT40(T)
Tindall Engineering Limited
942-3L EM (fail ElectroTwo HSTB barrel Electrosecure) USCH3 mechanical bolts mechanical access control three point locking access control lock with lock (fail secure) system 3 with key override shrouded thumb and lever handle turn override and lever handle
20 Nov 2011
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
A to M and AH to AN
399
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
400
MT40(T)
Tindall Engineering Limited
Electro942-3L EM (fail Two HSTB barrel Electromechanical secure) EPC bolts mechanical access control USCH3 three point access control lock with lock (fail secure) locking system3 with key override shrouded thumb and lever handle turn override and lever handle
MT41
Tindall Engineering Limited
Abryll EM 4 SATE Electromechanical (fail secure) access control USCH4 single point emergency lock (fail secure) with key override exit device3 and lever handle
Single action lever handle
Not applicable
B to M and AH to AN
MT41
Tindall Engineering Limited
Abryll EM 4 SATE Electromechanical (fail secure) EPC access control USCH4 single point emergency lock (fail secure) with key override exit device3 and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT42
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) USCH4 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action lever handle
Not applicable
B to M and AH to AN
MT42
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) EPC USCH4 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action lever handle
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT42(T)
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) USCH4 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action lever handle
Two HSTB barrel bolts
B to M and AH to AN
O, P, R, S, U, W, Y, AA, AC, AE, AG
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT42(T)
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) EPC USCH4 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action lever handle
MT43
Tindall Engineering Limited
Abryll EM 3 SATE Electro(fail secure) mechanical USCH4 single access control lock (fail secure) point lock3 with key override and lever handle
Thumb turn and lever handle
Not applicable
B to M and AH to AN
MT43
Tindall Engineering Limited
Abryll EM 3 SATE Electro(fail secure) EPC mechanical USCH4 single access control lock (fail secure) point lock3 with key override and lever handle
Thumb turn and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT44
Tindall Engineering Limited
Electro942-3L EM mechanical (fail secure) USCH4 three point access control lock (fail secure) locking system3 with key override and lever handle
Thumb turn and lever handle
Not applicable
B to M and AH to AN
MT44
Tindall Engineering Limited
Electro942-3L EM mechanical (fail secure) EPC USCH4 three point access control lock (fail secure) locking system3 with key override and lever handle
Thumb turn and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT44(T)
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) USCH4 three point access control lock (fail secure) locking system3 with key override and lever handle
Thumb turn and Two HSTB barrel lever handle bolts
20 Nov 2011
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
B to M and AH to AN
401
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
402
MT44(T)
Tindall Engineering Limited
Electro942-3L EM SATE mechanical (fail secure) EPC USCH4 three point access control lock (fail secure) locking system3 with key override and lever handle
MT45
Tindall Engineering Limited
Abryll EM 1 SATE Electro(fail secure) mechanical USCH4 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action push pad
Not applicable
B to M and AH to AN
MT45
Tindall Engineering Limited
Abryll EM 1 SATE Electro(fail secure) EPC mechanical USCH4 single access control point emergency lock (fail secure) with key override exit device3 and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT46
Tindall Engineering Limited
Electro942-3P EM SATE mechanical (fail secure) USCH4 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
Not applicable
B to M and AH to AN
MT46
Tindall Engineering Limited
Electro942-3P EM SATE mechanical (fail secure) EPC USCH4 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT46(T)
Tindall Engineering Limited
Electro942-3P EM SATE mechanical (fail secure) USCH4 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
Two HSTB barrel bolts
B to M and AH to AN
Thumb turn and Two HSTB barrel lever handle bolts
O, P, R, S, U, W, Y, AA, AC, AE, AG
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT46(T)
Tindall Engineering Limited
Electro942-3P EM SATE mechanical (fail secure) EPC USCH4 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
MT47
Tindall Engineering Limited
Abryll EM 2 SATE Electro(fail secure) mechanical USCH4 single access control point panic exit lock (fail secure) with key override device3 and lever handle
Panic bar
Not applicable
B to M and AH to AN
MT47
Tindall Engineering Limited
Abryll EM 2 SATE Electro(fail secure) EPC mechanical USCH4 single access control point panic exit lock (fail secure) with key override device3 and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT48
Tindall Engineering Limited
Electro942-3 EM SATE mechanical (fail secure) USCH4 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Not applicable
B to M and AH to AN
MT48
Tindall Engineering Limited
Electro942-3 EM SATE mechanical (fail secure) EPC USCH4 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT48(T)
Tindall Engineering Limited
Electro942-3 EM SATE mechanical (fail secure) USCH4 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Two HSTB barrel bolts
B to M and AH to AN
20 Nov 2011
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
403
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
404
MT48(T)
Tindall Engineering Limited
942-3 EM SATE Electro(fail secure) EPC mechanical USCH4 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Two HSTB barrel N, Q, T, V, X, Z, bolts AB, AD, AF
MT49
Tindall Engineering Limited
Abryll EM 1 (fail secure) USCH4 single point lock3
ElectroElectromechanical mechanical access control access control lock (fail secure) lock with with key override shrouded thumb and lever handle turn override and lever handle
Not applicable
B to M and AH to AN
MT49
Tindall Engineering Limited
Abryll EM 1 (fail secure) EPC USCH4 single point lock3
ElectroElectromechanical mechanical access control access control lock (fail secure) lock with with key override shrouded thumb and lever handle turn override and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT50
Tindall Engineering Limited
Electro942-3L EM (fail Electromechanical secure) USCH4 mechanical access control three point locking access control lock with lock (fail secure) system 3 with key override shrouded thumb and lever handle turn override and lever handle
Not applicable
B to M and AH to AN
MT50
Tindall Engineering Limited
Electro942-3L EM (fail Electromechanical secure) EPC mechanical access control USCH4 three point access control lock with lock (fail secure) locking system3 with key override shrouded thumb and lever handle turn override and lever handle
Not applicable
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT50(T)
Tindall Engineering Limited
Electro942-3L EM (fail Two HSTB barrel Electromechanical secure) USCH4 bolts mechanical access control three point locking access control lock with lock (fail secure) system 3 with key override shrouded thumb and lever handle turn override and lever handle
B to M and AH to AN
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES O, P, R, S, U, W, Y, AA, AC, AE, AG
Tindall Engineering Limited
MT54
Tindall Engineering Limited
Two HSTB barrel ElectroElectro942L EM bolts mechanical mechanical (fail secure) USCH5 three point access control access control lock (fail secure) lock with thumb locking system3 with key override turn override and lever handle and lever handle
B to M and AH to AN
MT54
Tindall Engineering Limited
Two HSTB barrel Electro942L EM Electrobolts mechanical (fail secure) EPC mechanical USCH5 three point access control access control lock (fail secure) lock with thumb locking system3 with key override turn override and lever handle and lever handle
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT55
Tindall Engineering Limited
Abryll EM1 SATE (fail secure) USCH5 single point emergency exit device3
Electromechanical access control lock (fail secure) with key override and lever handle
Single action push pad
Not applicable
B to M and AH to AN
MT55
Tindall Engineering Limited
Abryll EM1 SATE (fail secure) EPC USCH5 single point emergency exit device3
Electromechanical access control lock (fail secure) with key override and lever handle
Single action push pad
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT56
Tindall Engineering Limited
Electro942P EM SATE mechanical (fail secure) USCH5 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
Single action push pad
Two HSTB barrel bolts
B to M and AH to AN
20 Nov 2011
Abryll EM3 (fail secure) EPC USCH5 single point lock3
ElectroElectromechanical mechanical access control access control lock (fail secure) lock with thumb with key override turn override and lever handle and lever handle
Not applicable
MT53
405
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
406
MT56
Tindall Engineering Limited
Electro942P EM SATE mechanical (fail secure) EPC USCH5 three point access control emergency exit lock (fail secure) with key override device3 and lever handle
MT57
Tindall Engineering Limited
Abryll EM2 SATE (fail secure) USCH5 single point panic exit device3
Electromechanical access control lock (fail secure) with key override and lever handle
Panic bar
Not applicable
B to M and AH to AN
MT57
Tindall Engineering Limited
Abryll EM2 SATE (fail secure) EPC USCH5 single point panic exit device3
Electromechanical access control lock (fail secure) with key override and lever handle
Panic bar
Not applicable
N, Q, T, V, X, Z, AB, AD, AF
MT58
Tindall Engineering Limited
Electro942 EM SATE mechanical (fail secure) USCH5 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Two HSTB barrel bolts
B to M and AH to AN
MT58
Tindall Engineering Limited
Electro942 EM SATE mechanical (fail secure) EPC USCH5 three point access control panic exit device3 lock (fail secure) with key override and lever handle
Panic bar
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
MT59
Tindall Engineering Limited
Abryll EM3 (fail secure) USCH5 single point lock3
Single action push pad
ElectroElectromechanical mechanical access control access control lock (fail secure) lock with thumb with key override turn override and lever handle and lever handle
Two HSTB barrel N, Q, T, V, X, Z, AB, AD, AF bolts
Not applicable
B to M and AH to AN
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES O, P, R, S, U, W, Y, AA, AC, AE, AG
Tindall Engineering Limited
MT60
Tindall Engineering Limited
Two HSTB barrel ElectroElectro942L EM bolts mechanical mechanical (fail secure) USCH5 three point access control access control lock (fail secure) lock with thumb locking system3 with key override turn override and lever handle and lever handle
B to M and AH to AN
MT60
Tindall Engineering Limited
Two HSTB barrel Electro942L EM Electrobolts mechanical (fail secure) EPC mechanical USCH5 three point access control access control lock (fail secure) lock with thumb locking system3 with key override turn override and lever handle and lever handle
O, P, R, S, U, W, Y, AA, AC, AE, AG
MT61
Tindall Engineering Limited
Abryll PE 4 SATE single point emergency exit device
None
Single action lever handle
Not applicable
Not applicable
MT61(T)
Tindall Engineering Limited
Abryll PE 4 SATE single point emergency exit device
None
Single action lever handle
Two HSTB barrel bolts
Not applicable
MT62
Tindall Engineering Limited
942-3L three point emergency exit device
None
Single action lever handle
Not applicable
Not applicable
MT62(T)
Tindall Engineering Limited
942-3L three point emergency exit device
None
Single action lever handle
Two HSTB barrel bolts
Not applicable
MT63
Tindall Engineering Limited
Abryll AD 3 SATE single point lock
None
Thumb turn and lever handle
Not applicable
Not applicable
MT63(T)
Tindall Engineering Limited
Abryll AD 3 SATE single point lock
None
Thumb turn and Two HSTB barrel lever handle bolts
Not applicable
MT64
Tindall Engineering Limited
942-3L INT AD three point locking system
None
Thumb turn and lever handle
Not applicable
Not applicable
MT64(T)
Tindall Engineering Limited
942-3L INT AD three point locking system
None
Thumb turn and lever handle
Two HSTB barrel bolts
Not applicable
MT65
Tindall Engineering Limited
Abryll PE 1 SATE single point emergency exit device
None
Single action push pad
Not applicable
Not applicable
MT65(T)
Tindall Engineering Limited
Abryll PE 1 SATE single point emergency exit device
None
Single action push pad
Two HSTB barrel bolts
Not applicable
MT66
Tindall Engineering Limited
942-3P three point emergency exit device
None
Single action push pad
Not applicable
Not applicable
MT66(T)
Tindall Engineering Limited
942-3P three point emergency exit device
None
Single action push pad
Two HSTB barrel bolts
Not applicable
20 Nov 2011
Abryll EM3 (fail secure) EPC USCH5 single point lock3
ElectroElectromechanical mechanical access control access control lock (fail secure) lock with thumb with key override turn override and lever handle and lever handle
Not applicable
MT59
407
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES
408
MT67
Tindall Engineering Limited
Abryll PE 2 SATE single point panic exit device
None
Panic bar
Not applicable
Not applicable
MT67(T)
Tindall Engineering Limited
Abryll PE 2 SATE single point panic exit device
None
Panic bar
Two HSTB barrel bolts
Not applicable
MT68
Tindall Engineering Limited
942-3 three point panic exit device
None
Panic bar
Not applicable
Not applicable
MT68(T)
Tindall Engineering Limited
942-3 three point panic exit device
None
Panic bar
Two HSTB barrel bolts
Not applicable
MT69
Tindall Engineering Limited
Abryll EM 1 (fail secure) single point lock3
None
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
Not applicable
MT69(T)
Tindall Engineering Limited
Abryll EM 1 (fail secure) single point lock3
None
ElectroTwo HSTB barrel mechanical bolts access control lock with shrouded thumb turn override and lever handle
Not applicable
MT70
Tindall Engineering Limited
942-3L EM (fail secure) three point locking system3
None
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
MT70(T)
Tindall Engineering Limited
942-3L EM (fail secure) three point locking system3
None
ElectroTwo HSTB barrel mechanical bolts access control lock with shrouded thumb turn override and lever handle
MT71
Tindall Engineering Limited
Abryll PE 4 SATE single point emergency exit device
None
Single action lever handle
Not applicable
Not applicable
MT72
Tindall Engineering Limited
942-3L three point emergency exit device
None
Single action lever handle
Not applicable
Not applicable
MT72(T)
Tindall Engineering Limited
942-3L three point emergency exit device
None
Single action lever handle
Two HSTB barrel bolts
Not applicable
MT73
Tindall Engineering Limited
Abryll AD 3 SATE single point lock
None
Thumb turn and lever handle
Not applicable
Not applicable
Not applicable
Not applicable
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT74
Tindall Engineering Limited
942-3L INT AD three point locking system
None
Thumb turn and lever handle
Not applicable
Not applicable
MT74(T)
Tindall Engineering Limited
942-3L INT AD three point locking system
None
Thumb turn and lever handle
Two HSTB barrel bolts
Not applicable
MT75
Tindall Engineering Limited
Abryll PE 1 single point emergency exit device
None
Single action push pad
Not applicable
Not applicable
MT76
Tindall Engineering Limited
942-3P three point emergency exit device
None
Single action push pad
Not applicable
Not applicable
MT76(T)
Tindall Engineering Limited
942-3P three point emergency exit device
None
Single action push pad
Two HSTB barrel bolts
Not applicable
MT77
Tindall Engineering Limited
Abryll PE 2 single point panic exit device
None
Panic bar
Not applicable
Not applicable
MT78
Tindall Engineering Limited
942-3 three point panic exit device
None
Panic bar
Not applicable
Not applicable
MT78(T)
Tindall Engineering Limited
942-3 three point panic exit device
None
Panic bar
Two HSTB barrel bolts
Not applicable
MT79
Tindall Engineering Limited
Abryll EM 1 (fail secure) single point lock3
None
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
Not applicable
MT80
Tindall Engineering Limited
942-3L EM (fail secure) three point locking system3
None
Electromechanical access control lock with shrouded thumb turn override and lever handle
Not applicable
Not applicable
MT80(T)
Tindall Engineering Limited
942-3L EM (fail secure) three point locking system3
None
ElectroTwo HSTB barrel mechanical bolts access control lock with shrouded thumb turn override and lever handle
MT81
Tindall Engineering Limited
Abryll PE3 single point emergency exit device
None
Single action lever handle
Not applicable
Not applicable
MT82
Tindall Engineering Limited
942L three point emergency exit device
None
Single action lever handle
Two HSTB barrel bolts
Not applicable
MT83
Tindall Engineering Limited
Abryll AD3 single point lock
None
Thumb turn and lever handle
Not applicable
Not applicable
MT84
Tindall Engineering Limited
942L INT AD three point locking system
None
Thumb turn and Two HSTB barrel lever handle bolts
20 Nov 2011
Not applicable
Not applicable
409
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES MT85
Tindall Engineering Limited
Abryll PE1 single point emergency exit device
None
Single action push pad
Not applicable
Not applicable
MT86
Tindall Engineering Limited
942P three point emergency exit device
None
Single action push pad
Two HSTB barrel bolts
Not applicable
MT87
Tindall Engineering Limited
Abryll PE2 single point panic exit device
None
Panic bar
Not applicable
Not applicable
MT88
Tindall Engineering Limited
942 three point panic exit device
None
Panic bar
Two HSTB barrel bolts
Not applicable
MT89
Tindall Engineering Limited
Abryll EM3 (fail secure) single point lock3
None
Electromechanical access control lock with thumb turn override and lever handle
Not applicable
Not applicable
MT90
Tindall Engineering Limited
942L EM (fail secure) three point locking system 3
None
ElectroTwo HSTB barrel mechanical bolts access control lock with thumb turn override and lever handle
Not applicable
Compatible Cylinders
Cylinder Reference A
Manufacturer
B
Abloy
Protec CY201 PT
C
Abloy
Protec Cliq CY201
D
AMS
E
ASSA
CL-OVLD 4407dp
Scandinavian Oval (with tail) (Electo-mechanical)
F
ASSA
4407 Cliq
Scandinavian Oval (with tail) (Electo-mechanical)
G
ASSA
4807
Scandinavian Oval (with tail)
H
ASSA
C5807
Scandinavian Oval (with tail)
I
ASSA
Twin 7607
Scandinavian Oval (with tail)
J
Kaba
K20
Scandinavian Oval (with tail)
K
Kaba
Quattro PluS
L
Locken
M
Medeco
CL-PL2WR M3-ARX
N
Abloy
Protec CY304
O
Abloy
Protec Cliq CY333
410
Abloy
Model
Type
Disklock Pro CY201 DP Scandinavian Oval (with tail)
3
Scandinavian Oval (with tail) Scandinavian Oval (with tail) (Electo-mechanical) Scandinavian Oval (with tail)
3
P
Abloy
Protec CY333
Q
Abloy
Protec Cliq CY304
R
Abloy
Protec CY305
S
Abloy
Protec Cliq CY305
Scandinavian Oval (with tail) Scandinavian Oval (with tail) (Electo-mechanical) Scandinavian Oval (with tail) Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) (Electomechanical) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:key) (Electo-mechanical) Europrofile double cylinder (key:thumbturn) Europrofile double cylinder (key:thumbturn) (Electomechanical)
20 Nov 2011
PART 4: SECTION 5.1.1 HIGH SECURITY HINGED DOORSETS WITH PLAIN LEAVES T
ASSA
4422dp
Europrofile double cylinder (key:key)
U
ASSA
4427dp
Europrofile double cylinder (key:thumbturn)
V
ASSA
44M22 Cliq
W
ASSA
44M27 Cliq
Europrofile double cylinder (key:key) (Electo-mechanical) Europrofile double cylinder (key:thumbturn) (Electomechanical)
X
ASSA
4822
Europrofile double cylinder (key:key)
Y
ASSA
4827
Europrofile double cylinder (key:thumbturn)
Z
ASSA
C5822
Europrofile double cylinder (key:key)
AA
ASSA
C5827
Europrofile double cylinder (key:thumbturn)
AB
ASSA
7622
AC
ASSA
7627
AD
Kaba
Quattro PluS
Europrofile double cylinder (key:key)
AE
Kaba
Quattro PluS
Europrofile double cylinder (key:thumbturn)
AF
Medeco
M3-ARX
AG
Medeco
M3-ARX
AH
Abloy
Protec CY403
Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn)
Europrofile double cylinder (key:key) Europrofile double cylinder (key:thumbturn) Rim
AI
Abloy
Protec Cliq CY403
AJ
Kaba
Quattro Plus
Rim
AK
Medeco
M3-ARX
Rim
AL
AMS
3
AM
ASSA
CL-CA2D 4857
AN
ASSA
C5857
AO
Kaba
AP
Yale
KV06.100 (torque resistant) PK1109 (Pro key)
Rim(Electo-mechanical)
Finish Round (Electo-mechanical) Round threaded Round threaded Rim Rim
Options
Option Upper louver vent (200 mm by 220 mm)
Lower louver vent (200 mm by 220 mm)
Compatible Locking Systems SM1 to SM30, MT1 to MT20 and MT1(T) to MT20(T), MT31 to MT50 and MT31(T) to MT 50(T), MT61 to MT80 and MT61(T) to MT80(T) SM1, SM2, SM3, SM5, SM6, SM7, SM8, SM10, SM11, SM12, SM13, SM15, SM16, SM17, SM18, SM20, SM21, SM22, SM23, SM25, SM26, SM27, SM28, SM30, MT1, MT1(T), MT2, MT2(T), MT3, MT3(T), MT4, MT4(T), MT5, MT5(T), MT6, MT6(T), MT9, MT9(T), MT10, MT10(T), MT11, MT12, MT12(T), MT13, MT14, MT14(T), MT15, MT16, MT16(T), MT19, MT20, MT20(T), MT31, MT31(T), MT32, MT32(T), MT33, MT33(T), MT34, MT34(T), MT35, MT35(T), MT36, MT36(T), MT39, MT39(T), MT40, MT40(T), MT41, MT42, MT42(T), MT43, MT44, MT44(T), MT45, MT46, MT46(T), MT49, MT50, MT50(T), MT61, MT61(T), MT62, MT62(T), MT63, MT63(T), MT64, MT64(T), MT65, MT65(T), MT66, MT66(T), MT69, MT69(T), MT70, MT70(T), MT71, MT72, MT72(T), MT73, MT74, MT74(T), MT75, MT76, MT76(T), MT79, MT80, MT80(T)
Notes: 1
This approval covers double leaf doorsets with:
2
3
Leafs of equal width (450f/02, 450f/04 and 450f/06); and
Leafs of unequal width (450f/02 and 450f/04). Both leafs on these doors shall be between 300 mm and 975 mm wide. If only one barrel bolt on the passive leaf is engaged on configurations SM3, SM4, SM13, SM14, SM23, SM24, MT1(T) to MT10(T), MT31(T) to MT40(T) and MT61(T) to MT70(T), these configurations achieve Security Rating 1. Both barrel bolts must therefore be engaged to ensure that the doorsets meet the requirements of Security Rating 3. The resistance of the access control locks and electro-mechanical cylinders to “non-mechanical” attack is not covered by this approval as they were outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate these locking systems. This is because the scope of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that specifiers’ satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage.
20 Nov 2011
411
PART 4: SECTION 5.1.2 HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES
Blyweert Beaufort Aluminium Limited Imperial Park, Celtic Way, Newport NP10 8BE, United Kingdom Tel: +44 (0)1633 294040 • Fax: +44 (0)1633 294041 E-mail: [email protected] • Website: www.blyweertbeaufort.com Certificate No: 975a to LPS 1175: Issue 6
Hinged Security Doorset Product Name 'LPS 1175 Commercial Door'
Type Single leaf bidirectional glazed aluminium doorset with anti-finger trap hinges and two deadlocks on the leading edge
Minimum Height (m) 1.8
Maximum Height (m) 2.2
Minimum Width (m) 0.9
Maximum Width (m) 1.2
Security Rating 21
Cert. No. 975a/01
Compatible Locking System
Manufacturer Model
Adams Rite
Sentinel 6
Type
Com patible Cylinders
Deadlock fitted w ith the Adams Rite Sentinel security escutcheon and lock face plate
Manufacturer
Model
Type
Adams Rite
CL1-ED3535-SC-KD Double europrofile cylinder (key:key)
Compatible Glazing Material
Manufacturer
Model
Type
Hamilton Erskine
TECDUR SR2/SR3 DGU
28 mm thick double glazing unit
Notes: 1. The doorset achieves Security Rating 2 in the optimum locked condition, i.e. when both locks are engaged. A Security Rating 1 classification is achieved when only one lock is engaged. 2. The quality of work conducted by those fabricating and installing the doorset can affect the products’ ability to offer resistance to forced entry commensurate with that of the Security Rating attributed to the doorset. It is therefore recommended that the doorset is sourced from fabricators that hold LPCB approval for the fabrication of this doorset.
Bradbury Security Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888 E-mail: [email protected] • Website: www.bradburyuk.com Certificate No: 312e to LPS 1175: Issue 7
Hinged Security Doorsets Product Name
Product Type
M2M3 Combat
Single leaf outward opening doorset Double leaf outward opening doorset
412
Minimum Structural Opening Height (m) 1.745
Maximum Structural Opening Height (m) 2.43
Minimum Structural Opening Width (m) 0.74
Maximum Structural Opening Width (m) 1.18
Security Rating
Cert. No.
3
312e/01
1.745
2.43
1.15
2.20
3
312e/02
20 Nov 2011
PART 4: SECTION 5.1.2 HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES Product Name
Product Type
M2M3 Substation
Single leaf outward opening doorset Double leaf outward opening doorset
Minimum Structural Opening Height (m) 1.745
Maximum Structural Opening Height (m) 2.43
Minimum Structural Opening Width (m) 0.74
Maximum Structural Opening Width (m) 1.18
Security Rating
Cert. No.
3
312e/03
1.745
2.43
1.15
2.20
3
312e/04
Note 1.
Refer to Volume 2 Part 4 Section 5.1.1 for full details of the sizes, locking devices and accessories approved on the M2M3 doorset ranges.
C W Fields and Son Limited Station Road Industrial Estate, Epworth, Nr. Doncaster, South Yorkshire DN9 1JZ, United Kingdom Tel: +44 (0)1427 872368 • Fax: +44 (0)1427 873057 E-mail: [email protected] • Website: www.cwfields.co.uk Certificate No: 940a to LPS 1175: Issue 6
Hinged Security Doorsets Product Name Fields Security
Type Single leaf outward opening hinged security doorset Single leaf outward opening hinged security doorset with fixed/removable over panels Single leaf inward opening hinged security doorset Single leaf inward opening hinged security doorset with fixed/removable over panels Double leaf outward opening hinged security doorset Double leaf outward opening hinged security doorset with fixed/removable over panels Double leaf inward opening hinged security doorset Double leaf inward opening hinged security doorset with fixed/removable over panels
Security Rating 2 2
Cert. No. 940a/01 940a/02
2 2 2 2
940a/03 940a/04 940a/05 940a/06
2 2
940a/07 940a/08
Note: 1. Refer to Volume 2 Part 4 Section 5.1.1 for full details of the sizes, locking systems and accessories approved on the Fields Security doorset range.
Design & Supply Limited 13 Pant Industrial Estate, Merthyr Tydfil, Mid Glamorgan CF48 2SR, United Kingdom Tel: +44 (0)1685 350114 • Fax: +44 (0)1685 723276 E-mail: [email protected] Certificate No: 694b to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Type
Desray
Single leaf outward opening hinged security doorset
20 Nov 2011
Minimum Structural Opening Height (m) 1.8
Maximum Structural Opening Height (m) 2.2
Minimum Structural Opening Width (m) 0.75
Maximum Structural Opening Width (m) 1.3
Security Rating
Cert. No.
2
694b/01
413
PART 4: SECTION 5.1.2 HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES Product Name
Type
Double leaf outward opening hinged security doorset
Minimum Structural Opening Height (m) 1.8
Maximum Structural Opening Height (m) 2.2
Minimum Structural Opening Width (m) 1.5
Maximum Structural Opening Width (m) 2.5
Security Rating
Cert. No.
2
694b/02
Note 1.
Refer to Volume 2 Part 4 Section 5.1.1 for full details of the locking systems and accessories approved on the Desray doorsets.
Fendor Limited Heworth House, William Street, Felling, Gateshead NE10 0JP, United Kingdom Tel: +44 (0)191 438 3222 • Fax: +44 (0)191 438 1686 E-mail: [email protected] • Website: www.fendor.co.uk Certificate No: 712b to LPS 1175: Issue 5
Hinged Security Doorsets Product Name
Type
SecureLine
Single leaf outward opening hinged security doorsets Single leaf inward opening hinged security doorsets Double leaf outward opening hinged security doorsets Double leaf inward opening hinged security doorsets
Minimum Clear Opening Height (m) 2.0
Maximum Clear Opening Height (m) 2.6
Minimum Clear Opening Width (m) 0.85
Maximum Clear Opening Width (m)
Security Rating
Cert. No.
1.4
2
712b/01
2.0
2.6
0.85
1.4
2
2.0
2.6
1.5
2.8
2
2.0
2.24
1.5
2.8
2
Compatible Locking Devices and Glazing
LPCB Ref. No. 712b/01
Product Type Nam e SecureLine Single leaf outw ard opening hinged security doorsets Single leaf inw ard opening hinged security doorsets Double leaf outw ard opening hinged security doorsets Double leaf inw ard opening hinged security doorsets
Lock
Cylinder
Glazing2
Adams Rite MS2000 maximum security deadlock model 2200210 w ith barbolt Adams Rite MS2000 maximum security deadlock model 2200210 w ith barbolt Adams Rite MS2000 maximum security deadlock model 2200250 w ith hookbolt and top/bottom rods Adams Rite MS2000 maximum security deadlock model 2200250 w ith hookbolt and top/bottom rods
Assa Sofi 4822 Europrofile double cylinder (key:key) Assa Sofi 4822 Europrofile double cylinder (key:key) Assa Sofi 4822 Europrofile double cylinder (key:key)
16 mm thick specialist laminated glazing unit
Assa Sofi 4822 Europrofile double cylinder (key:key)
16 mm thick specialist laminated glazing unit
16 mm thick specialist laminated glazing unit 16 mm thick specialist laminated glazing unit
Notes 1. The SecureLine doorsets should be mounted within the reveal, directly into the surrounding structure in accordance with Fendor Hansen installation instructions SR2+/03. 2. Alternative glazing may not provide equivalent resistance to attack. Therefore, please consult Fendor Hansen before replacing or changing the glazing.
414
20 Nov 2011
PART 4: SECTION 5.1.2 HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES
Liddle Doors Limited Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698 E-mail: [email protected] • Website: www.liddledoors.co.uk Certificate No: 442b to LPS 1175: Issue 6
Hinged Security Doorsets Product Name Liddle Series 3
Type Single leaf outward opening hinged doorset Double leaf outward opening hinged doorset
Minimum Height (m) 1.8
Maximum Height (m) 2.2
Minimum Width (m) 0.75
Maximum Width (m) 1.2
Security Rating 3
Cert. No. 442b/01
1.8
2.2
1.4
2.0
3
442b/02
Vision Panels
Product Name
Vision Panels
Liddle Series 3
200 mm wide by 40 mm high vision panel
Compatible Doorset Configurations Single Leaf Outward Opening Double Leaf Outward Opening
Note 1.
Refer to Volume 2 Part 4 Section 5.1.1 for full details of the locking systems approved on the Liddle Series 3 doorsets.
MultiSteel Limited MultiSteel House, 117-119 Brent Terrace, London NW2 1LL, United Kingdom Tel: +44 (0)20 8208 8300 • Fax: +44 (0)20 8208 8209 E-mail: [email protected] • Website: www.multisteel.co.uk Certificate No: 818a to LPS 1175: Issue 6
Hinged Security Doorsets Product Name
Type
Minimum Height (m)
Maximum Height (m)
Minimum Width (m)
Maximum Width (m)
Multisteel 'Mag Lock'
Single leaf outward opening doorset1, 2 Single leaf outward opening doorset1, 2
1.83
2.43
0.647
1.83
2.43
0.575
Multisteel '3 Point Mul-TLock'
Security Rating
Cert. No.
1.377
Compatible Locking Systems 1
1
818a/01
1.425
2
2
818a/02
Compatible Locking Systems
20 Nov 2011
415
PART 4: SECTION 5.1.2 HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES Locking System Reference 1
Manufacturer Securitron
2
Mul-T-Lock
Locking System Model Type Magnalock M32 Pair of (top of leaf) and electromagnetic locks M32c (bottom of leaf)
235
Multipoint mortise lock
Operating Devices Compatible Cylinders External Face Internal Face Not applicable ‘Entrotec low rise ‘Entrotec DDA panel with DDA push to exit’ push features’ access button release4 control panel with PAC panel reader (PAC20085)3 Key and lever handle
Key and lever handle
A or B
Compatible Cylinders
Cylinder Reference A B
Manufacturer Mul-T-Lock Mul-T-Lock
Model Garrison Interactive
Type Double euro-profile cylinder (key:key) Double euro-profile cylinder (key:key)
Notes
1. 2. 3.
4.
The doorsets may be used within the walling systems falling within the scope of the ‘Multisteel security screen’ modular security screen walling system (LPCB certificate reference 818b/01), for example, to form communal entrance systems. The doorsets are available with either glazed or opaque panels. The access control system’s resistance to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175. It is therefore recommended that specifiers satisfy themselves that the components used are resistant to any environmental conditions/interference that may cause the locking system to disengage. The push button must be located at least 1.5 m from the doorset and any associated side and over panels.
Stafford Bridge Doors Limited Bedford Road, Pavenham, Bedford MK43 7PS, United Kingdom Tel: +44 (0)1234 826316 • Fax: +44 (0)1234 826319 E-mail: [email protected] • Website: www.surelockmcgillgroup.com/sbd Certificate No: 516a to LPS 1175: Issue 5
Hinged Doorsets Product Name
Type
Sandhurst
Single leaf, outward and inward opening hinged security doorset Single leaf, outward and inward opening hinged security doorset Double leaf, outward opening hinged security doorset
Hendon Sandhurst
Minimum Structural Opening Height (m) 1.9
Maximum Structural Opening Height (m) 2.5
Minimum Structural Opening Width (m) 0.7
Maximum Structural Opening Width (m) 1
Security Rating
Cert. No.
3
516a/01
1.9
2.5
0.7
1
2
516a/02
1.9
2.5
1.4
2
3
516a/05
Note 1.
416
Refer to Volume 2 Part 4 Section 5.1.1 for full details of the locking systems and accessories approved on the Sandhurst and Hendon doorsets.
20 Nov 2011
PART 4: SECTION 5.1.2 HIGH SECURITY HINGED DOORSETS WITH GLAZED LEAVES
Sunray Engineering Limited Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137 E-mail: [email protected] • Website: www.sunraydoors.co.uk Certificate No: 234d to LPS 1175: Issue 7
Hinged Security Doorsets Product Name
Type
ExcluDoor 3 Mk2
Single leaf, outward opening hinged security doorset with vision panel Double leaf, outward opening hinged security doorset with vision panel Single leaf, outward opening hinged security doorset with vision panel Double leaf, outward opening hinged security doorset with vision panel Single leaf, outward opening hinged security doorset with vision panel doorset with vision panel
ExecDoor 2
ExcluDoor 4 Mk2
Minimum Clear Opening Height (m) 1.8
Maximum Clear Opening Height (m) 2.4
Minimum Clear Opening Width (m) 0.75
Maximum Clear Opening Width (m)
Security Rating
Cert. No.
1.24
3
234d/01
1.8
2.4
1.24
2.4
3
234d/02
1.8
2.2
0.75
1.3
2
234d/03
1.8
2.2
1.5
2.5
2
234d/04
1.8
2.4
0.75
1.24
4
234d/05
1.8
2.4
1.24
2.4
4
234d/06
Note: 1. Refer to Volume 2 Part 4 Section 5.1.1 for full details of the locking systems and accessories approved on the ExecDoor 2, ExcluDoor 3 Mk2 and ExcluDoor 4 Mk2 doorsets.
20 Nov 2011
417
PART 4: SECTION 5.1.3 HIGH SECURITY HINGED DOORSETS WITH OTHER LEAF DESIGNS
Lowrey Contractors Limited 200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111 E-mail: [email protected] • Website: www.lowrey-contractors.co.uk Certificate No: 974a to LPS 1175: Issue 7
Hinged Mesh Panel Security Doorsets Product Name
Type
Lowrey Level 1 Single Leaf Mesh Security Doorset Lowrey Level 1 Double Leaf Mesh Security Doorset
Single leaf outward opening mesh panel doorset Double leaf outward opening mesh panel doorset Single leaf outward opening mesh panel doorset Double leaf outward opening mesh panel doorset Single leaf outward opening mesh panel doorset Double leaf outward opening mesh panel doorset
Lowrey Level 2 Single Leaf Mesh Security Doorset Lowrey Level 2 Double Leaf Mesh Security Doorset Lowrey Level 3 Single Leaf Mesh Security Doorset Lowrey Level 3 Double Leaf Mesh Security Doorset
Minimum Height (m) 1.0
Maximum Height (m) 2.4
Minimum Width (m) 0.6
Maximum Width (m) 1.3
Security Rating 1
Cert. No. 974a/01
1.0
2.4
1.2
2.6
1
974a/02
1.0
2.4
0.6
1.3
2
974a/03
1.0
2.4
1.2
2.6
2
974a/04
1.0
2.4
0.6
1.3
3
974a/05
1.0
2.4
1.2
2.6
3
974a/06
Compatible Locking Devices1, 2
Manufacture Locking Device
Type
Cylinder
Approved Product (LPCB Ref. No. 974a/..) 01
02
03
04
05
06
Abloy
Abloy PL330/25 (V01) HP
Padlock
Abloy High Profile
Abloy
Abloy PL330/25 (V01) EX
Padlock
Abloy Exec
Abloy
Abloy PL330/25 (V01) PT
Padlock
Abloy Protec
Abloy
Abloy PL340/25 (V01) HP
Padlock
Abloy High Profile
Abloy
Abloy PL340/25 (V01) EX
Padlock
Abloy Exec
Abloy
Abloy PL340/25 (V01) PT
Padlock
Protec
Abloy
Abloy PL342 (V01) HP
Padlock
Abloy High Profile
Abloy
Abloy PL342 (V01) EX
Padlock
Abloy Exec
Abloy
Abloy PL342 (V01) PT
Padlock
Abloy Protec
Abloy
Abloy PL350/25 (V01) HP
Padlock
Abloy High Profile
Abloy
Abloy PL350/25 (V01) EX
Padlock
Abloy Exec
Padlock
Abloy Protec
Kaba K20-C5
Abloy Kaba
Abloy PL350/25 (V01) PT Kaba K18 w ith 11 mm open Padlock shackle (Item No. K180010-SS)
Notes: 1. Certification does not cover the use of locks other than those listed. Utilisation of unlisted locks may affect the level of security offered by the doorset. 2. The ‘user friendliness’ of employing the padlocks listed has not been assessed as this is beyond the scope of LPS 1175: Issue 7. 3. The Lowrey security mesh doorsets are approved when installed in accordance with the instructions detailed on Lowrey document EINST004 (Issue 4).
418
20 Nov 2011
PART 4: SECTION 5.1.3 HIGH SECURITY HINGED DOORSETS WITH OTHER LEAF DESIGNS
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Certificate No: 450j to LPS 1175: Issue 7
Hinged Mesh Panel Security Doorset Product Name Ultrasecure SCD1 Ultrasecure SCD2
Product Type Single leaf outward opening mesh panel doorset Double leaf outward opening mesh panel doorset
Minimum Height (m) 1
Maximum Height (m) 3
Minimum Width (m) 0.5
Maximum Width (m) 1.2
Security Rating 3
Cert. No. 450j/01
1
3
1.2
3
3
450j/02
Compatible Locking Devices
Locking Device Type
Kaba K18
Cylinder
Padlock Kaba 20 with C5 option
Approved Product (LPCB Ref. No. 450j/..) 01
02
Notes 1. 2. 3.
Certification does not cover the use of locks other than those listed above. Utilisation of unlisted locks may affect the level of security offered by the doorset. The ‘user friendliness’ of employing the padlock listed above has not been assessed as this is beyond the scope of LPS 1175: Issue 7. The Ultrasecure SCD1 and SCD2 mesh panel doorsets are approved when installed in accordance with the instructions detailed on document SCD-DV-3-FIT-01 (Ref.A).
20 Nov 2011
419
PART 4: SECTION 5.1.4 HIGH SECURITY FOLDING DOORSETS
Bolton Gate Co. Limited Waterloo Street, Bolton, Lancashire BL1 2SP, United Kingdom Tel: +44 (0)1204 871000 • Fax: +44 (0)1204 871049 E-mail: [email protected] • Website: www.boltongate.co.uk Certificate No: 026-2b to LPS 1175: Issue 5
Folding Security Doorsets Minimum Clear Opening Width (m) 1.70
Maximum Clear Opening Height (m) 6.00
Maximum Clear Opening Width (m) 4.65
Security Rating
Cert. No.
4
Minimum Clear Opening Height (m) 3.00
4
026-2b/01
6
3.00
2.60
6.00
7.00
4
8
3.00
3.55
6.00
8.00
4
4
3.00
1.70
6.00
4.65
5
6
3.00
2.60
6.00
7.00
5
8
3.00
3.55
6.00
8.00
5
Product Name
Type
Number of Door Panels
Superfold 4000
Sliding folding panel security door set1 Sliding folding panel security door set1 Sliding folding panel security door set1 Sliding folding panel security door set1 Sliding folding panel security door set Sliding folding panel security door set
Superfold 5000
026-2b/02
Compatible Locking Devices
LPCB Ref. No. Trade Name 026-2b/01 Superfold 4000 026-2b/02 Superfold 5000
Locking Device Chubb 7009 padbar and Chubb 1K11 padlock2 Chubb 7009 padbar and Chubb 1K11 padlock2
Notes 1. 2.
420
Single stack back configuration only. The locking device is mounted on the "non-attack" face of the doorset. Therefore, although not currently covered by the scope of the approval, other padlocks may be suitable for use on the doorsets.
20 Nov 2011
PART 4: SECTION 5.2.1 DOMESTIC DOORSETS APPROVED TO PAS 23-1
Doorsets listed in this section are approved to PAS 23-1 General performance requirements for door assemblies - Part 1. Single leaf, external door assemblies to dwellings. This standard describes a series of test methods and a range of criteria relevant to the general performance of single leaf, single swing, external door assemblies to dwellings. The scope of the standard covers inward and outward opening doorsets, with or without integral or coupled side panels and fanlights. Where these are covered by the LPCB certificate, details will be provided in the listing for that product. The scope of the standard does not cover the installation of the product nor does it cover double leaf doors, sliding doors, folding doors, tilt and slide doors, and pivoted doors, or doors with any frame member over 3m. For details of hinged doorsets approved to LPS 1175 and PAS 24-1 please refer to sections 5.1 and 5.2.2 respectively.
IR Martin Roberts, IR Security & Safety Limited Millen Road, Sittingbourne, Kent ME10 2AA, United Kingdom Tel: +44 (0)1795 476161 • Fax: +44 (0)1795 422463 E-mail: [email protected] • Website: www.irmartinroberts.co.uk Certificate No: 322b to PAS23-1: 1999 (Incorporating Amendment No. 1)
Hinged Security Doorsets Product Name
Type
Martin Roberts SD5001 Martin Roberts SD5001(1)
Direction of Opening
Single leaf, hinged security doorsets Single leaf, hinged security doorsets
Minimum Clear Opening Width (m) 0.503
Maximum Clear Opening Height (m) 3.049
Maximum Clear Opening Width (m) 1.332
Exposure Category
Cert. No.
Outward
Minimum Clear Opening Height (m) 0.951
800U
322b/02
Inward
0.951
0.503
2.250
1.332
800U
Compatible Locking Options
LPCB Ref. Trade Name No.
Type
322b/02
Single leaf, hinged security doorsets
Martin Roberts SD5001
Direction of Opening
Compatible Locking Systems
Outward Inward
2 1
Compatible Locking Systems
Option 1
Locking System Assa 1520
Type Escape Sash Lock
2
Assa 8761
Emergency Nightlatch
Compatible External and Internal Operating Devices External Internal Key via an Assa 4801 single Assa 6650C solid brass handle plus either cylinder or Key via an Assa 4802 double Assa 6256 thumbturn or Key via an Assa 4802 double cylinder cylinder Key via an Assa 4801 single Assa 640 solid brass handle cylinder
Note 1.
The Martin Roberts SD5001 also meets the requirements of LPS 1175: Issue 5 and PAS 24-1:1999. For further information, please refer to entries in sections on LPS 1175: Issue 5 and PAS 24-1 relating to LPCB certificates 322a and 322c respectively.
20 Nov 2011
421
PART 4: SECTION 5.2.1 DOMESTIC DOORSETS APPROVED TO PAS 23-1
Salisbury Glass Centre Limited Newton Road, Churchfields Industrial Estate, Salisbury, Wiltshire SP2 7QA, United Kingdom Tel: +44 (0)1722 342900 • Fax: +44 (0)1722 338784 E-mail: [email protected] or [email protected] • Website: www.salisbury-glass.com Certificate No: 947a to PAS 23-1:1999 (incorporating amendments Nos. 1, 2, 3 and 4 and Corrigendum No. 1) and PAS 24:2007
Hinged Doorsets Product Name
Type
Visoline
Fully glazed single leaf outward opening aluminium doorset
Minimum Structural Opening Height (m) 1.85
Maximum Structural Opening Height (m) 2.2
Minimum Structural Opening Width (m) 0.8
Maximum Structural Opening Width (m) 1.05
Cert. No. 947a/01
Notes 1. 2.
422
This doorset achieves exposure category '850 Special'. Refer to Volume 2 Part 4 Section 5.2.2 for full details of the locking systems and compatible cylinders approved on the doorsets.
20 Nov 2011
PART 4: SECTION 5.2.2 DOMESTIC DOORSETS APPROVED TO PAS 24-1
Doorsets listed in this section are approved to PAS 24-1 Enhanced security requirements for door assemblies - Part 1. Single and double leaf, external door assemblies to dwellings. This standard describes a series of test methods and a range of criteria relevant to the general performance of single and double leaf, single swing, hinged external door assemblies for dwellings. The scope of the standard covers inward and outward opening doorsets, with or without integral or coupled side panels and fanlights. Where these are covered by the LPCB certificate, details will be provided in the listing for that product. The scope of the standard does not cover the installation of the product nor does it cover sliding doors, folding doors, tilt and slide doors, and pivoted doors, or doors with any frame member over 3m. The concept of ‘enhanced security’ in this product standard is based upon a relationship between forced human intervention techniques with basic hand tools and resistance to entry under multi-directional loading and hard and soft body impact tests. The standard provides a means of evaluation of resistance to opportunist attack. The standard does not provide a means of evaluating the protection provided against unauthorised intrusion to the levels of attack or scope of entry methods covered within LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. The ability to gain entry by picking the locks, deliberately breaking the glass or by attacking the frame fixing methods is not addressed in PAS 24-1. For details of hinged doorsets approved to LPS 1175 and PAS 23-1 please refer to sections 5.1 and 5.2 respectively.
IR Martin Roberts, IR Security & Safety Limited Millen Road, Sittingbourne, Kent ME10 2AA, United Kingdom Tel: +44 (0)1795 476161 • Fax: +44 (0)1795 422463 E-mail: [email protected] • Website: www.irmartinroberts.co.uk Certificate No: 322c to PAS24-1: 1999 (Incorporating Amendment No 1)
Hinged Security Doorsets Product Name
Type
Direction of Opening
Martin Roberts SD5001
Single leaf, hinged security doorsets Single leaf, hinged security doorsets
20 Nov 2011
Outward
Minimum Clear Opening Height (m) 0.951
Minimum Clear Opening Width (m) 0.503
Maximum Clear Opening Height (m) 3.049
Maximum Clear Opening Width (m) 1.332
Inward
0.951
0.503
2.250
1.332
Cert. No.
322c/02
423
PART 4: SECTION 5.2.2 DOMESTIC DOORSETS APPROVED TO PAS 24-1 Compatible Locking Options
LPCB Ref. Trade Name No. 322c/02 Martin Roberts SD5001
Type Single leaf, hinged security doorsets
Direction of Opening Outward Inward
Compatible Locking Systems 2 1
Compatible Locking Systems
Option
Locking System
Type
Compatible External and Internal Operating Devices
1
Assa 1520
Escape Sash Lock
2
Assa 8761
Emergency Nightlatch Key via an Assa 4801 single cylinder
External Key via an Assa 4801 single cylinder or Key via an Assa 4802 double cylinder
Internal Assa 6650C solid brass handle plus either Assa 6256 thumbturn or Key via an Assa 4802 double cylinder Assa 640 solid brass handle
Note 1.
The Martin Roberts SD5001 also meets the requirements of LPS 1175: Issue 5 and PAS 23-1: 1999. For further information, please refer to entries in sections on LPS 1175: Issue 5 and PAS 23-1 relating to LPCB certificates 322a and 322b respectively.
Salisbury Glass Centre Limited Newton Road, Churchfields Industrial Estate, Salisbury, Wiltshire SP2 7QA, United Kingdom Tel: +44 (0)1722 342900 • Fax: +44 (0)1722 338784 E-mail: [email protected] or [email protected] • Website: www.salisbury-glass.com Certificate No: 947a to PAS 23-1:1999 (incorporating amendments Nos. 1, 2, 3 and 4 and Corrigendum No. 1) and PAS 24:2007
Hinged Doorsets Product Name
Type
Visoline
Fully glazed single leaf outward opening aluminium doorset
Minimum Structural Opening Height (m) 1.85
Maximum Structural Opening Height (m) 2.2
Minimum Structural Opening Width (m) 0.8
Maximum Structural Opening Width (m) 1.05
Cert. No. 947a/01
Compatible Locking Systems
Manufacturer
Model
Type
Sobinco
ACVL 415
Multipoint locking system
Operating Devices External Face Internal Face Key and Hoppe Key and Hoppe Tokyo PAS24 Tokyo PAS24 lever handle set lever handle set
Compatible Cylinders A
Compatible Cylinders
Cylinder Reference Manufacturer A Securistyle
Model Anti-manipulation
Type Double europrofile cylinder (key/key)
Note 1. This doorset achieves exposure category '850 Special'.
424
20 Nov 2011
PART 4: SECTION 5.3 HIGH SECURITY WINDOWS
The windows listed in this section are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. The windows listed in this section are generally designed for use in commercial applications. Section 5.3.1 lists external security windows while section 5.3.2 lists secondary glazing systems and section 5.3.3 lists rooflights. Windows approved to BS 7950 Specification for enhanced security performance of windows for domestic applications are listed in section 5.4. Unlike BS 7950, LPS 1175 can be applied to all designs and configurations of windows. Windows approved to LPS 1175 also generally offer much higher protection against forced entry than windows approved to BS 7950. This is because windows approved to LPS 1175 are subjected to physical attack tests with a wide range of tools aimed at overcoming all aspects of the window including aspects omitted by BS 7950 such as the glazing and the fixings used to install the window. In addition to approving windows to LPS 1175 and BS 7950, LPCB also offer security performance approval of windows and other façade elements to EN 1627 as well as approvals covering other aspects of window performance, including weathertightness, thermal performance, fire and acoustics. LPCB has also published a standard for glazing and security glazing films which employs the principles contained within LPS 1175. LPS 1270 Requirements and testing procedures for the LPCB approval and listing of intruder resistant security glazing units covers the resistance to manual attack of the glazing material. It enables specifiers to select new or replacement glazing that affords two levels of security equivalent to that of the frame or façade in which it is to be employed.
20 Nov 2011
425
PART 4: SECTION 5.3.1 HIGH SECURITY WINDOWS - EXTERNAL WINDOWS
Fendor Limited Heworth House, William Street, Felling, Gateshead NE10 0JP, United Kingdom Tel: +44 (0)191 438 3222 • Fax: +44 (0)191 438 1686 E-mail: [email protected] • Website: www.fendor.co.uk Certificate No: 712a to LPS 1175: Issue 5.1
Security Windows Product Name
Style
SecureLine SR2
Fixed light window
SecureLine SR3 SecureLine SR4
Minimum Clear Opening Height (m) 0.96
Maximum Clear Opening Height (m) 2.0
Minimum Clear Opening Width (m) 0.86
Maximum Clear Opening Width (m)
Security Rating
Cert. No.
2.0
2
712a/01
1.0
2.0
0.90
2.0
2
0.96
2.0
0.86
2.0
3
1.0
2.0
0.90
2.0
3
0.96
2.0
0.86
2.0
4
Top hung opening light window Fixed light window Top hung opening light window Fixed light window
712a/02
712a/03
Compatible Locking Devices and Glazing
LPCB Ref. No. 712a/01
712a/02
712a/03
Product Nam e SecureLine SR2
SecureLine SR3
SecureLine SR4
Style
Locking
Fixed light w indow
N/A
Glazing 2 Attack Face 8mm thick specialist laminated glazing unit
Top hung opening light w indow
Tw o Wilka dead locks w ith key operated cylinders
32.8mm thick 8mm thick specialist laminated specialist laminated glazing unit double glazed unit
Fixed light w indow
N/A
32.8mm thick 10mm thick specialist laminated specialist laminated glazing unit double glazed unit
Top hung opening light w indow
Tw o Wilka dead locks w ith key operated cylinders
32.8mm thick 10mm thick specialist laminated specialist laminated glazing unit double glazed unit
Fixed light w indow
N/A
28mm thick 32.8mm thick specialist laninated specialist laminated glazing unit double glazed unit
Non-attack Face 32.8mm thick specialist laminated double glazed unit
Notes 1. 2.
426
The SecureLine window systems should be mounted within the reveal, directly into the surrounding structure in accordance with installation instructions SL-02 (fixed light version) or SL-007 (top hung opening light version). Alternative glazing may not provide equivalent resistance to attack. Therefore, please consult Fendor Ltd before replacing or changing the glazing.
20 Nov 2011
PART 4: SECTION 5.3.2 HIGH SECURITY WINDOWS - SECONDARY GLAZING SYSTEMS
Selectaglaze Limited Alban Park, Hatfield Road, St Albans, Hertfordshire AL4 0JJ, United Kingdom Tel: +44 (0)1727 837271 • Fax: +44 (0)1727 844053 E-mail: [email protected] • Website: www.selectaglaze.co.uk Certificate No: 683a to LPS 1175: Issue 6
Secondary Security Glazing Systems Product Name
Type
Style
Series 50 'Level 1'
Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system
Single fixed light casement
Series 50 'Level 2'
Series 55 'Level 1'
Series 55 'Level 2'
20 Nov 2011
Minimum Height (m) 0.4
Maximum Height (m) 1 3.23
Minimum Width (m) 0.4
Maximum Width (m)1 3.23
Security Rating
Cert. No.
1
683a/01
0.43
1.53
0.574
3.23
1
0.574
3.23
0.43
1.53
1
0.4
3.23
0.4
3.23
2
0.43
1.53
0.574
3.23
2
0.574
3.23
0.43
1.53
2
0.4
3.23
0.8
43
1
2V multiple fixed light demountable unit
0.8
43
0.4
3.23
1
3H multiple fixed light demountable unit
0.4
3.23
1.2
53
1
3V multiple fixed light demountable unit
1.2
53
0.4
3.23
1
4H multiple fixed light demountable unit
0.4
3.23
1.6
63
1
5H multiple fixed light demountable unit
0.4
3.23
2
63
1
Single demountable fixed-light unit
0.4
3.23
0.4
3.23
1
Single demountable fixed light unit
0.4
3.23
0.4
3.23
2
2H multi-light demountable unit
0.4
3.23
0.8
43
2
3H multi-light demountable unit
0.4
3.23
1.2
53
2
4H multi-light demountable unit
0.4
3.23
1.6
63
2
5H multi-light demountable unit
0.4
3.23
2
63
2
Single light inward opening top hung casement Single light inward opening side hung casement Single fixed light casement Single light inward opening top hung casement Single light inward opening side hung casement 2H multiple fixed light demountable unit
683a/02
683a/03
683a/04
427
PART 4: SECTION 5.3.2 HIGH SECURITY WINDOWS - SECONDARY GLAZING SYSTEMS Product Name
Series 55 'Level 3'
Series 85 'Level 1' Series 85 'Level 2' Series 95 'Level 1' Series 95 'Level 2' Series 42 'Level 1' Series 42 'Level 2'
Type
Style
Minimum Height (m) 0.8
Maximum Height (m) 1 43
Minimum Width (m) 0.4
Maximum Width (m)1 3.23
Security Rating
Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system Secondary glazing system
2V multi-light demountable unit
Cert. No.
3V multi-light demountable unit
1.2
53
0.4
3.23
2
Single demountable fixed light unit
0.4
3.2
0.4
3.2
3
2H multi-light demountable unit
0.4
3.2
0.8
4
3
3H multi-light demountable unit
0.4
3.2
1.2
5
3
4H multi-light demountable unit
0.4
3.2
1.6
6
3
5H multi-light demountable unit
0.4
3.2
2
6
3
2V multi-light demountable unit
0.8
4
0.4
3.2
3
3V multi-light demountable unit
1.2
5
0.4
3.2
3
Twin light horizontally sliding casement
0.65
2.67
1
37
1
683a/05
Twin light horizontally sliding casement
0.65
2.67
1
37
2
683a/07
Twin light vertically sliding casement
1
32, 7
0.65
2.62, 7
1
683a/08
Twin light vertically sliding casement
1
32, 7
0.65
2.62, 7
2
683a/09
Single fixed light unit
0.3
37
0.3
27
1
683a/10
Single fixed light unit
0.3
37
0.3
27
2
683a/11
2
683a/06
Compatible Locking and Glazing
LPCB Ref. No. 683a/01
Trade Name
Style
Series 50 'Level 1'
All single fixed light casements None
683a/02
Series 50 'Level 2'
683a/03
Series 55 'Level 1' Series 55 'Level 2'
683a/04
428
Locking System s
Glazing4
12.04 mm thick specialist laminated security glass 12.04 mm thick specialist laminated All single light inw ard opening Selectaglaze proprietary top hung and side hung espagnolette locking system w ith security glass casements Softline LM lockable handle All single fixed light casements None 12 mm or 12.4 mm thick specialist laminated security glass All single light inw ard opening Selectaglaze proprietary 12 mm or 12.4 mm thick specialist top hung and side hung espagnolette locking system w ith laminated security glass casements Softline LM lockable handle 12.04 mm thick specialist laminated All single and multiple light None security glass demountable units All single and multiple light None 12 mm or 12.4 mm thick specialist demountable units laminated security glass
20 Nov 2011
PART 4: SECTION 5.3.2 HIGH SECURITY WINDOWS - SECONDARY GLAZING SYSTEMS 683a/06 683a/05 683a/07 683a/08 683a/09 683a/10 683a/11
Series 55 'Level 3' Series 85 'Level 1' Series 85 'Level 2'
All single and multiple light demountable units Tw in light horizontally sliding casements Tw in light horizontally sliding casements
None Selectaglaze proprietary espagnolette locking system Selectaglaze proprietary espagnolette locking system
12 mm thick specialist laminated security glass 12.04 mm thick specialist laminated security glass 12 mm or 12.4 mm thick specialist laminated security glass
Series 95 'Level 1' Series 95 'Level 2'
Tw in light vertically sliding casements Tw in light vertically sliding casements
Selectaglaze proprietary espagnolette locking system Selectaglaze proprietary espagnolette locking system
12.04 mm thick specialist laminated security glass 12 mm or 12.4 mm thick specialist laminated security glass
Series 42 'Level 1' Series 42 'Level 2'
Single fixed light units
None
Single fixed light units
None
12.04 mm thick specialist laminated security glass 12 mm or 12.4 mm thick specialist laminated security glass
Compatible Installation Configurations
LPCB Ref. Trade Nam e No.
Com patible Installation Configurations 5 Masonry
Structural Tim ber
Tim ber Stud
Structural Steel
683a/01
Series 50 'Level 1'
I and R
I and R
I and R
I and R6
683a/02
Series 50 'Level 2'
I and R6
I and R6
-
I and R6
683a/03
Series 55 'Level 1'
I and R6
I and R6
I and R
I and R6
683a/04
Series 55 'Level 2'
I and R
6
I and R
-
I and R6
683a/06
Series 55 'Level 3'
I and R6
I and R6
-
I and R6
683a/05
Series 85 'Level 1'
I and R
I and R
I and R
I and R
683a/07
Series 85 'Level 2'
I and R
I and R
-
I and R
683a/08
Series 95 'Level 1'
I and R
I and R
I and R
I and R
683a/09
Series 95 'Level 2'
I and R
I and R
-
I and R
683a/10
Series 42 'Level 1'
I and R
I and R
I and R
I and R
683a/11
Series 42 'Level 2'
I and R
I and R
-
I and R
6
6
6
6
Notes: 1 The maximum size of casements and coupled systems are subject to specific assessment of physical restrictions and operational conditions. 2 The maximum sash area available on Series 95 units is 3.5 m2. 3 The Series 50 and Series 55 'Level 1' and 'Level 2' units can be joined together to form multi-light flat-coupled and bay systems using the Selectaglaze standard coupling, direct coupling and timber coupling methods, as appropriate. The security provided is equivalent to that offered by the lowest grade unit incorporated in the coupled system. 4 Alternative glazing may not provide equivalent resistance to attack. Therefore, please consult Selectaglaze before replacing or changing the glazing. 5 This assumes installation direct to substrate as detailed in document DS-003 (Issue AR, 07/049) and not via intermediate substrates, such as plasterboard. An 'I' indicates internal face fixed direct to structure while an 'R' indicates reveal mounted direct to structure. 6 The Series 50 and Series 55 secondary glazing system may be mounted in the reveal (standard, tapered or splayed) or face fixed to the inside of the surrounding structure. 7 The Series 42, 85 and 95 'Level 1' and 'Level 2' units can be joined together to form multi-light flat-coupled and bay systems using the Selectaglaze standard coupling and timber coupling methods, as appropriate. The security provided is equivalent to that offered by the lowest grade unit incorporated in the coupled system.
20 Nov 2011
429
PART 4: SECTION 5.3.3 ROOFLIGHTS
The Rooflight Company Wychwood Business Centre, Milton Road, Shipton-under-Wychwood, Oxfordshire OX7 6XU, United Kingdom Tel: +44 (0)1993 833108 • Fax: +44 (0)1993 831066 E-mail: [email protected] • Website: www.therooflightcompany.co.uk Certificate No: 929a to LPS 1175: Issue 6
Fixed Rooflights Product Name
Type
Plateau Secured by Design: Level 2 Plateau Secured by Design: Level 3
Fixed rooflight Fixed rooflight with integral security bars
Minimum Length (m) 0.96
Maximum Length (m) 1.76
Minimum Width (m) 0.96
Maximum Width (m) 2.76
Security Rating
Cert. No.
2
929a/01
0.96
0.96
0.96
2.76
3
929a/02
Note
1
Approval is based upon installation of the rooflight onto a reinforced concrete kerb in accordance with drawing PS_100INST (Revision B dated 14 August 2009).
430
20 Nov 2011
PART 4: SECTION 5.4 DOMESTIC SECURITY WINDOWS
Windows listed in this section are approved against the requirements of BS 7950 Specification for enhanced security performance of windows for domestic applications. The scope of windows covered by BS 7950 is restricted to the following: (i) (ii) (iii) (iv) (v)
Casement windows - inward and outward opening side hung, outward opening top hung and inward opening bottom hung. Tilt/turn and turn/tilt windows. Fixed lights and dummy vents. Top swing. Vertical sliding.
BS 7950 does not assess the resistance to entry by breaking glazing nor does it directly assess the fixing method employed. The concept of ‘enhanced security’ in this product standard is based upon a relationship between forced human intervention techniques with basic hand tools and resistance to entry under multi-directional loading and hard and soft body impact tests. The standard provides a means of evaluation of resistance to opportunist attack. The standard does not provide a means of evaluating the protection provided against unauthorised intrusion to the levels of attack or scope of entry methods covered within LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. It is recommended that specifiers requiring windows outside the scope of BS 7950 or windows that exhibit resistance to methods of forced entry not covered by BS 7950, specify windows that have been approved to LPS 1175 (see products listed in section 5.3). Alternatively, specifiers should consider specifying additional window protection; such as grilles, shutters or secondary glazing systems; approved to LPS 1175. In addition to approving windows to LPS 1175 and BS 7950, LPCB also offer security performance approval of windows and other façade elements to EN 1627 as well as approvals covering other aspects of window performance, including weathertightness, thermal performance, fire and acoustics. LPCB has also published a standard for glazing and security glazing films which employs the principles contained within LPS 1175. LPS 1270 Requirements and testing procedures for the LPCB approval and listing of intruder resistant security glazing units covers the resistance to manual attack of the glazing material. It enables specifiers to select new or replacement glazing that affords two levels of security equivalent to that of the frame or façade in which it is to be employed.
PRO TEC Vinduer A/S Nybovej 34, 7500 Holstebro, Denmark Tel: +45 9741 3077 • Fax: +45 9741 3060 E-mail: [email protected] • Website: www.protecvinduer.com UK Sales PRO TEC Windows Limited, The Plough Barn, Feltmores Park, Chalk Lane, Moor Hall Road, Harlow CM17 0PF, United Kingdom Tel: +44 (0)127 942 4004 • Fax: +44 (0)127 942 1709 E-mail: [email protected] • Website: www.protecwindows.com
Certificate No: 930a to BS 7950: 1997, BS 6375-1: 2004 and BS 6375-2: 1987
20 Nov 2011
431
PART 4: SECTION 5.4 DOMESTIC SECURITY WINDOWS Windows Product Name
Type
PRO TEC Classic
Aluminium/timber composite single fixed light windows Aluminium/timber composite single top hung casement windows Aluminium/timber composite single side hung casement windows Aluminium/timber composite single terrace side hung casement windows
Minimum Structural Opening Height (m) 0.35
Maximum Structural Opening Height (m) 3
Minimum Structural Opening Width (m) 0.230
Maximum Structural Opening Width (m) 3
Compatible Locking System
Cert. No.
-
930a/01
0.353
1.563
0.353
1.563
1
930a/02
0.363
1.763
0.353
0.953
1
930a/03
1.713
2.463
0.661
1.063
1
930a/04
Approval Standards
LPCB Ref. Trade Name No. 930a/01 930a/02
PRO TEC Classic PRO TEC Classic
930a/03
PRO TEC Classic
930a/04
PRO TEC Classic
Type
Aluminium/timber composite single fixed light windows Aluminium/timber composite single top hung casement windows Aluminium/timber composite single side hung casement windows Aluminium/timber composite single terrace side hung casement windows
BS 7950: BS 6375-1: BS 6375-2: UK 1997 2004 1987 Exposure Category Refer to 1200 note 1 1200
1200
1200
Compatible Locking System
Compatible Locking Manufacturer System 1 Mila A/S
Model
Type
Garant D28
Multipoint locking system incorporating four locking points and key lockable handle
Note 1. Fixed light windows are outside the scope of BS 6375-2: 1987.
Salisbury Glass Centre Limited Newton Road, Churchfields Industrial Estate, Salisbury, Wiltshire SP2 7QA, United Kingdom Tel: +44 (0)1722 342900 • Fax: +44 (0)1722 338784 E-mail: [email protected] or [email protected] • Website: www.salisbury-glass.com Certificate No: 947b to BS 7950: 1997, BS 6375-1: 2004, BS 6375-2: 1987 and BS 4873: 2004
432
20 Nov 2011
PART 4: SECTION 5.4 DOMESTIC SECURITY WINDOWS Domestic Window Product Name
Type
Visoline
Internally glazed inward opening tilt/turn aluminium window
Minimum Structural Opening Height (m) 0.8
Maximum Structural Opening Height (m) 2
Minimum Structural Opening Width (m) 0.7
Maximum Structural Opening Width (m) 1.2
Compatible Locking Systems
Cert. No.
1
947b/01
Approval Standards
LPCB Ref. No.
Trade Name
Type
BS 7950:1997
947b/01
Visoline
Internally glazed inw ard opening tilt/turn aluminium w indow
BS 6375-1:2004 BS 6375-2:1987 (UK Exposure Category) 2000+
BS 4873:2004
Compatible Locking Systems
Compatible Manufacturer Locking System 1 Fappin
Model
Type
ACFA 061
Multi point tilt/turn locking system w ith additional ACFA 078 locking points and ACFA 082 key locking handle on the internal face.
Note: 1. This approval only covers single light units. Certificate No: 947c to BS 7950: 1997, BS 6375-1: 2009, BS 6375-2: 2009 and BS 4873: 2009
Domestic Window Product Name
Type
Technal FXi52
Inward opening tilt/turn aluminium window1
Minimum Structural Opening Height (m) 0.6
Maximum Structural Opening Height (m) 2.38
Minimum Structural Opening Width (m) 0.6
Maximum Structural Opening Width (m) 1.26
Compatible Locking System
Cert. No.
1
947c/01
Compatible Locking System
Com patible Locking System 1
Manufacturer
Model
Type
Operating Devices External Face Internal Face
Seigenia
SI-line TBT 90
Key locking handle
Seigenia
SI-line LM 4200 TBT-E-WK2
Tilt/turn locking system
None
Key locking handle
Exposure Category
Cert. No.
Trade Name
Type
UK Exposure Cate gory
947c/01
Technal FXi52
Inw ard opening tilt/turn aluminium w indow
2000+
Note: 1. This approval covers single light units.
20 Nov 2011
433
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS
Security grilles, blinds and barsets listed in this section are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers.
Bradbury Security Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888 E-mail: [email protected] • Website: www.bradburyuk.com Certificate No: 312a to LPS 1175: Issue 5
Security Grilles Product Name
Type
CX2
Single gate collapsible security grille Double gate collapsible security grille
Minimum Height (m) 0.7
Maximum Height (m) 3.0
Minimum Width (m) 0.4
Maximum Width (m) 3.0
Security Rating
Cert. No.
1
312a/04
0.7
3.0
0.4
6.0
1
Compatible Locking Devices
LPCB Ref. No.
312a/04
Lock Bradbury CX500 two point slam lock
Bradbury CX250 two point slam lock
Cylinders Bradbury CX1000 two point slam lock CX2 single or double Europrofile cylinder
Approved Accessories None. Approved Installation Configurations1
Configuration Brick Reveal Internal face fixed
Substrate Concrete Structural Steel
Structural Timber
Note 1.
This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.
Henry Lewis and Sons (Wireworkers) Limited Unit 7, Bolling Road Industrial Estate, Bradford BD4 7HN, United Kingdom Tel: +44 (0) 1274 307359 • Fax: +44 (0) 1274 370784 E-mail: [email protected] • Website: www.henrylewisandson.co.uk Certificate No: 528a to LPS 1175: Issue 5
Security Grilles Product Name
Type
Balmoral
Single gate collapsible grille
434
Minimum Width (mm) 500
Maximum Width (mm) 6000
Minimum Height (mm) 650
Maximum Height (mm) 3046
Security Rating
Cert. No.
1
528a/01
20 Nov 2011
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS Product Name
Type Double gate collapsible grille Fixed grille
Minimum Width (mm) 500
Maximum Width (mm) 6000
Minimum Height (mm) 650
Maximum Height (mm) 3046
Security Rating
Cert. No.
1
528a/02
500
6000
650
3046
1
528a/03
Compatible Locking Devices
Lock
Cylinder
Adams Rite MS1900
ASEC AS 1193 single europrofile ASEC AS 1153 double europrofile
Approved Product (LPCB Ref. No. 528a/…) 1 2 3
Approved Accessories
Approved Product (LPCB Ref. No. 528a/…)
Accessory
1
Removable bottom track Lift up (hinged) bottom track
2
3
Approved Installation Configurations1
Configuration Brick Reveal Internal face External face
Compatible Substrates Concrete Structural Steel
Structural Timber
Note 1. This assumes installation direct to substrate and not via intermediate substrates such as plasterboard.
Liddle Doors Limited Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698 E-mail: [email protected] • Website: www.liddledoors.co.uk Certificate No: 442d to LPS 1175: Issue 6
Fixed Security Bar Sets Product Name
Type
Liddle Series 2 security bar set
Reveal mounted security bar set
Liddle Series 3 security bar set
Internally or externally face fixed security bar set Reveal mounted security bar set
20 Nov 2011
Minimum Structural Opening Height (m) 0.4
Maximum Structural Opening Height (m) 2.7
Minimum Structural Opening Width (m) 0.4
Maximum Structural Opening Width (m) 3.0
Security Rating
Cert. No.
2
442d/01
0.1
2.24
0.1
2.54
2
0.4
2.7
0.4
3.0
3
442d/02
435
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS Product Name
Type
Internally or externally face fixed security bar set
Minimum Structural Opening Height (m) 0.1
Maximum Structural Opening Height (m) 2.24
Minimum Structural Opening Width (m) 0.1
Maximum Structural Opening Width (m) 2.54
Security Rating
Cert. No.
3
Note 1.
The bar sets are approved when installed directly to brickwork, concrete or steel. The approval does not cover the bar sets when mounted to alternative substrates or via intermediate substrates such as plasterboard.
Lowrey Contractors Limited 200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111 E-mail: [email protected] • Website: www.lowrey-contractors.co.uk Certificate No: 974g to LPS 1175: Issue 7
Fixed Security Barsets Product Name AntiIntruder
Product Type Individual security barset Individual security barset Individual security barset Modular security barset Modular security barset Modular security barset
Installation
Minimum Height (m) 0.55
Maximum Height (m) 2.1
Minimum Width (m) 0.55
Maximum Width (m) 2.1
Security Rating 3
External face fixed
0.45
2.0
0.45
2.0
3
Internal face fixed
0.45
2.0
0.45
2.0
3
Reveal mounted
0.55
Unlimited1
0.55
Unlimited1
3
External face fixed
0.45
Unlimited1
0.45
Unlimited1
3
Internal face fixed
0.45
Unlimited1
0.45
Unlimited1
3
Reveal mounted
Cert. No. 974g/01
Notes: 1. The maximum minor dimension approved is 4.1 m. This is because the number of individual barsets that can be connected is restricted to a maximum of two in the minor dimension. However, the barset’s size is unrestricted in the major direction. 2. The barsets are approved when installed in accordance with the instructions detailed on document SB/3BS/INS (Issue 4).
Professional Barrier Systems Limited 16 Stapledon Road, Orton Southgate, Peterborough PE2 6TD, United Kingdom Tel: +44 (0)1733 361511 • Fax: +44 (0)1733 361512 E-mail: [email protected] • Website: www.extendor.co.uk Certificate No: 869a to LPS 1175: Issue 6
Security Grilles Product Name
Type
Extendor Eclipse
Fixed security grille
436
Minimum Height (m) 0.5
Maximum Height (m) 3.58
Minimum Width (m) 0.3
Maximum Width (m) 5.75
Security Rating
Cert. No.
3
869a/01
20 Nov 2011
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS Product Name
Type Single sash collapsible security grille Double sash collapsible security grille Flexi single and multiple sash collapsible security grille
Minimum Height (m) 0.625
Maximum Height (m) 2.7
Minimum Width (m) 0.39
Maximum Width (m) 5.75
Security Rating
Cert. No.
3
1
0.625
2.7
0.44
11.5
3
0.625
2.7
0.44
Unlimited1
3
Compatible Locking Devices
Product Name
Type
Lock
Compatible Cylinders 1 to 3
Extendor Eclipse Single sash collapsible security grille Extendor Eclipse CL03 lock with CL03 cylinder guard2 Double sash collapsible security Extendor Eclipse CL03 lock grille with CL03 cylinder guard2 ‘Flexi’ single and multiple sash Extendor Eclipse CL03 lock collapsible security grille with CL03 cylinder guard2
1 to 3 1 to 3
Compatible Cylinders
Compatible Cylinders 1 2 3
Cylinders Assa dp4400 single europrofile CISA AP3S single europrofile Kaba Quattro Plus single europrofile
Approved Accessories Recessed track and deep rail cover channel. Approved Installation Configurations3
Configuration Brickwork
Reveal Internal Face
Substrate Concrete Concrete Blockwork
Structural Timber
Notes 1. 2. 3.
The maximum width of any sash is 5.75 m. The CL03 cylinder guard is only required for protecting cylinders on the attack side of the grille. Installation into other substrates should be assessed by LPCB to ensure the installation method offers compatible resistance to attack.
Safeguard Security, a trade name of WBH Industries Unit 5, 229 Torrington Avenue, Coventry CV4 9HN, United Kingdom Tel: +44 (0)2476 470 600 • Fax: +44 (0)2476 471 600 E-mail: [email protected] • Website: www.safeguardsecurity.co.uk Certificate No: 418a to LPS 1175: Issue 5
Security Grilles Product Name
Type
LPC1 System
Single gate, collapsible security grille Double gate, collapsible security grille
20 Nov 2011
Minimum Height (m) 0.594
Maximum Height (m) 3.0
Minimum Width (m) 0.233
Maximum Width (m)
Security Rating
Cert. No.
6.0
1
418a/01
0.594
3.0
0.405
12.0
1
437
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS
Compatible Locking Devices
LPCB Ref. No. 418a/01
Product Name
Type
Locks
Cylinder
LPC1 System
Single and double gate collapsible security grille
Adams Rite MS 1900 hook lock
Sofi 5-pin single Europrof ile
Approved Installations Configurations1
Configuration
Substrate Brick
Concrete
Blockw ork
Timber
Steel
Reveal Internal face fixed
Note: 1. This assumes installation direct to the substrate and not via intermediate substrates, such as plasterboard.
Security Blinds Limited Units 3 A/B, Hope Street, Thornhill Industrial Estate, Rotherham S60 1LH, United Kingdom Tel: +44 (0)1709 363535 • Fax: +44 (0)1709 364512 E-mail: [email protected] • Website: www.securityblinds.co.uk Certificate No: 854a to LPS 1175: Issue 5
Security Blinds Product Name
Model
Type
Secur
950031
Single leaf inward opening vertical blind unit Single leaf inward opening vertical blind unit with transom Double leaf horizontal sliding verticial blind unit Double leaf horizontal sliding vertical blind unit with transom
950032
950033 950034
Minimum Height (m) 0.5
Minimum Width (m) 0.324
Maximum Height (m) 2.5
Maximum Width (m) 1.399
SecurityRating
Cert. No.
2
854a/01
0.5
0.324
2.5
1.3999
2
0.5
0.918
2.5
3.018
2
0.5
0.918
2.5
3.018
2
Compatible Locking Devices
LPCB Ref. Model No. 854a/01 950031
Lock
Cylinder
CISA 46270-25 tw o w ay locking system
C2000 European single europrofile cylinder
950032 950033 950034 Approved Installation Configurations1
Configuration Reveal
Substrate Brick
Concrete
Blockw ork
Note: 1. This assumes installation direct to the substrate and not via intermediate substrates, such as plasterboard.
438
20 Nov 2011
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS
Simbars (UK) Limited Unit 2, 46 Ashton Vale Road, Ashton, Bristol BS3 2HQ, United Kingdom Tel: +44 (0)117 953 1444 • Fax: +44 (0)117 963 1444 E-mail: [email protected] • Website: www.simbars.co.uk Certificate No: 932a to LPS 1175: Issue 6
Fixed Security Bar Sets Product Name
Type
Simbars security bar sets SR3
Reveal mounted security bar set
Simbars security bar sets SR4
Minimum Structural Opening Height (m) 0.6
Maximum Structural Opening Height (m) 8.0
Minimum Structural Opening Width (m) 0.6
Maximum Structural Opening Width (m) 6.0
Security Rating
Cert. No.
3
932a/01
0.14
7.54
0.14
5.54
3
0.225
8.0
0.225
6.0
4
0.227
7.54
0.29
5.54
4
Internally face fixed security bar set Reveal mounted security bar set Internally face fixed security bar set
932a/02
Note 1.
The bar sets are approved when installed directly to structural concrete using the fixings specified on drawings A1-00056 Revision F and A1-00104 Revision B (Internal face fixed) and A1-00057 Revision E and A1-00108 Revision C (Reveal mounted). The approval does not cover the bar sets when mounted to alternative substrates or via intermediate substrates such as plasterboard.
SWS UK Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411 E-mail: [email protected] • Website: www.swsuk.co.uk Certificate No: 390a to LPS 1175: Issue 5
Security Grilles Product Name
Type
SeceuroGuard 1001
Single gate collapsible security grille Fixed security grille
SeceuroGuard 1001 "Fixed" SeceuroGuard 1001 "Floating" SeceuroGuard 1001 SeceuroGuard 1001s SeceuroGuard 1001s "Fixed" SeceuroGuard 1001s "Floating"
20 Nov 2011
Minimum Height (m) 1
Minimum Width (m) 0.5
Maximum Height (m) 3
Maximum Width (m) 3
Security Rating
Cert. No.
1
390a/01
1
0.5
3
3
1
Single gate collapsible security grille Double gate collapsible security grille Single gate collapsible security grille Fixed security grille
1
0.5
3
3
1
1
1
3
6.5
1
1
0.5
3
3
1
1
0.5
3
3
1
Single gate collapsible security grille
1
0.5
3
3
1
390a/03
439
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS Product Name
Type
SeceuroGuard 1001s
Double gate collapsible security grille
Minimum Height (m) 1
Minimum Width (m) 1
Maximum Height (m) 3
Maximum Width (m) 6.5
Security Rating
Cert. No.
1
Compatible Locking Devices
LPCB Ref. Trade Name No. SeceuroGuard 1001 390a/01 SeceuroGuard 1001 “Fixed” SeceuroGuard 1001 “Floating” SeceuroGuard 1001 390a/03
S-lattice SeceuroGuard 1001s S-lattice SeceuroGuard 1001s “Fixed” S-lattice SeceuroGuard 1001s “Floating” S-lattice SeceuroGuard 1001s
Type
Locks
Single gate collaps ible security grille Fixed security grille
Viro 8300 extens ible gate lock with 5-pin cylinder N/A
Single gate collaps ible security grille Double gate collapsible security grille Single gate collaps ible security grille Fixed security grille
Viro 8300 extens ible gate lock with 5-pin cylinder Viro 8300 extens ible gate lock with 5-pin cylinder Viro 8300 extens ible gate lock with 5-pin cylinder N/A
Single gate collaps ible security grille Double gate collapsible security grille
Viro 8300 extens ible gate lock with 5-pin cylinder Viro 8300 extens ible gate lock with 5-pin cylinder
Approved Accessories
Accessory
Associated Products (LPCB Ref. No. 390a/...) 1 3
Folding bottom track1
Approved Installation Configurations2
Configuration
Reveal Internal face fixed
2
Brick
Concrete
Substrate Structural Steel
Structural Timber
Notes 1. 2.
The folding bottom track is approved as an option on the single gate and double gate SeceuroGuard 1001 and SeceuroGuard 1001s models only. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.
The Expanded Metal Company Limited P.O.Box 14, Longhill Industrial Estate (North), Hartlepool TS25 1PR, United Kingdom Tel: +44 (0)1429 867 388 • Fax: +44 (0)1429 867 355 E-mail: [email protected] • Website: www.expandedmetalfencing.co.uk Certificate No: 731d to LPS 1175: Issue 6
440
20 Nov 2011
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS Fixed Security Window Guard Product Name
Type
Class 3 Window Guard
Rectangular security window guards with square vertical bars1 Rectangular security window guards with round vertical bars2
Minimum Structural Opening Height (m) 0.5
Maximum Structural Opening Height (m) 4.0
Minimum Structural Opening Width (m) 0.5
Maximum Structural Opening Width (m) 2.0
Security Rating
Cert. No.
3
731d/01
0.5
4.0
0.5
2.0
3
731d/02
Notes 1. 2. 3.
The window guards are approved when reveal mounted directly into solid brickwork or concrete structures of equivalent resistance to attack in accordance with the installation instructions contained in documents C3WG/RHS/P1 (Issue B), C3WG/RHS/P2 (Issue A), C3WG/RHS/P3 (Issue A) and C3WG/RHS/P4 (Issue A). The window guards are approved when reveal mounted directly into solid brickwork or concrete structures of equivalent resistance to attack in accordance with the installation instructions contained in drawings C3WG/BAR/P1 (Issue B), C3WG/BAR/P2 (Issue A), C3WG/BAR/P3 (Issue A) and C3WG/BAR/P4 (Issue A). The approval does not cover the window guards when mounted to alternative substrates or via intermediate substrates such as plasterboard.
Trellicor (Pty) Limited 20 Aberdare Drive, Phoenix Industrial Park, Durban, South Africa Tel: +27 31 500 4301 • Fax: +27 31 507 2129/3973 Certificate No: 474a to LPS 1175: Issue 5
Security Grilles Product Name
Model
Type
Trellidor Trojan II
Standard
Single gate collapsible security grille Single gate collapsible security grille Single gate collapsible security grille Single gate collapsible security grille Double gate collapsible security grille Double gate collapsible security grille Single gate collapsible security grille Single gate collapsible security grille Double gate collapsible security grille Double gate collapsible security grille
Flexi
Fixture Double Double flexi Trellidor Trojan II EMESC
Standard Flexi Double Double flexi
Minimum Height (m) 1.195
Minimum Width (m) 1.0
Maximum Height (m) 3.0
Maximum Width (m) 5.0
Security Rating
Cert. No.
2
474a/04
1.195
1.0
3.0
5.0
2
1.195
1.0
3.0
5.0
2
1.195
2.0
3.0
10.0
2
1.195
2.0
3.0
10.0
2
1.780
1.0
3.0
5.0
2
1-780
1.0
3.0
5.0
2
1.780
2.0
3.0
10.0
2
1.780
2.0
3.0
10.0
2
474a/05
Compatible Locking Devices
20 Nov 2011
441
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS
LPCB Ref. Trade No. Name
474a/04
474a/05
Model
Lock
Cylinder Trellidor double europrofile (key:key)
(key:thumbturn)1
-
-
Trellidor single europrofile
Trellidor Trojan II
Trellidor Trojan II EMESC
Standard Flexi Fixture Double Double flexi Standard Flexi Double Double flexi
Trellilok (Mark IV) Trellilok (Mark IV) N/A Trellilok (Mark IV) Trellilok (Mark IV)
Trellidor double europrofile
-
-
-
-
-
-
-
-
-
Trellilok (Mark IV) Trellilok (Mark IV) Trellilok (Mark IV) Trellilok (Mark IV)
Approved Installation Configurations2
LPCB Ref. No.
Product Name
474a/04
Trellidor Trojan II
474a/05
Trellidor Trojan II EMESC
Configuration
Substrate Brick
Concrete Blockwork
Stone
Structural Steel
Structural Timber
Reveal
Reveal
Notes 1. 2.
Thumbturn is located on non-attack side of the grille with a protection shroud. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.
Certificate No: 474b to LPS 1175: Issue 6
Security grilles Product Name
Model
Type
Trellidor Plus
Standard
Single gate collapsible security grille Single gate collapsible security grille Single gate collapsible security grille Double gate collapsible security grille
Flexi Fixture Double
Minimum Height (m) 0.945
Minimum Width (m) 0.6
Maximum Height (m) 3.0
Maximum Width (m) 5.0
Security Rating
Cert. No.
1
474b/01
0.945
1.0
3.0
5.0
1
0.945
0.6
3.0
5.0
1
0.945
1.0
3.0
10.0
1
Compatible Locking Devices
LPCB Ref. No.
474b/01
442
Model
Standard Flexi Fixture Double
Lock
Trellilok (Mark IV) Trellilok (Mark IV) N/A Trellilok (Mark IV)
Trellidor single europrofile N/A
Cylinder Trellidor double europrofile N/A
20 Nov 2011
PART 4: SECTION 5.5 SECURITY GRILLES, BLINDS AND BARSETS Approved Accessories
Accessory
Approved Product (LPCB Ref. No. 474b/...) 01
Hinged bottom track Rem ovable bottom track
Approved Instllation Configurations1
Configuration Reveal
Brick
Concrete
Substrate Structural Steel
Structural Timber
Note 1.
This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.
20 Nov 2011
443
PART 4: SECTION 5.6 SECURITY SHUTTERS
Security shutters listed in this section are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. In addition to approving shutters to LPS 1175, LPCB also offer security performance approval of shutters to EN1627 aswell as approvals covering other aspects of shutter performance including weathertightness, thermal performance, fire and acoustics.
Aluroll Limited Mile Oak Industrial Estate, Maesbury Road, Oswestry, Shropshire SY10 8GA, United Kingdom Tel: +44 (0)800 977 8975 • Fax: +44 (0)1691 671 482 E-mail: [email protected] • Website: www.aluroll.co.uk Certificate No: 931a to LPS 1175: Issue 6
Security Shutters Product Name
Type
E37 Elite
Externally face fitted double skin aluminium roller shutter Internally face fitted double skin insulated roller shutter Internally face fitted aluminium roller shutter with vision slats Internally face fitted aluminium roller shutter
T77 Elite (1)
V77 Elite
E77 Elite
Minimum Structural Opening Height (m) 0.9
Maximum Structural Opening Height (m) 4.0
Minimum Structural Opening Width (m)
Maximum Structural Opening Width (m)
Maximum Door Area (m2
Compatible Locking Devices
Security Rating
Cert. No.
0.77
3.0
8.5
A
1
931a/01
0.92
5.2
0.9
5.0
20
B
1
931a/02
0.92
5.2
0.9
5.0
25
B
2
931a/03
0.92
5.2
0.9
5.0
25
B
2
931a/04
Compatible Locking Devices
Compatible Locking Device A
B
Locking / Operating Devices External
Internal
Tw o Hopkins bullet H75 locks plus w ireless keypad and/or keyfob motor control3 and external manual override handle protected by Alukon 380370100 locking cap Wireless keypad and/or keyfob motor control3
Push button motor control4
Push button motor control4 w ith internal manual override handle5
Compatible Substrates
444
20 Nov 2011
PART 4: SECTION 5.6 SECURITY SHUTTERS Trade Name Type
Compatible Substrates Masonry
Steelw ork
Aluminium
E37 Elite
Externally face fitted double skin aluminium roller shutter
T77 Elite
Internally face fitted double skin insulated roller shutter
2
V77 Elite
Internally face fitted aluminium roller shutter w ith vision slats
2
E77 Elite
Internally face fitted aluminium roller shutter
2
Notes: 1. The T77 Elite is also marketed as an Elite garage door. That is available over the same size range and with same locking devices. 2. The T77 Elite, V77 Elite and E77 Elite roller shutters must have a minimum structural opening height of 2 m when installed on aluminium substrates. 3. The resistance of the wireless keypad and keyfob motor control to “non-mechanical” attack is not covered by this approval as they are outside the scope of LPS 1175. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of the wireless keypad and keyfob motor control equipment. It is therefore recommended that specifiers’ satisfy themselves that the components used are either resistant other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage. 4. The push button controller should be located on the protected side of the shutter at least 1.5 m from the shutter curtain. 5. The manual override handle should be stored on the protected side of the shutter at least 1.5 m from the shutter curtain.
Ascot Doors Limited Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800 E-mail: [email protected] • Website: www.ascotdoors.co.uk Certificate No: 131b to LPS 1175: Issue 3
Security Shutters Product Name
Type
A320
Rolling shutter
Minimum Height (m) 2
Maximum Height (m) 7
Minimum Width (m) 2.5
Maximum Width (m) 9
Security Rating
Cert. No.
4
131b/01
Compatible Locking Devices LPCB Ref. No. 131b/01
Product Name A320
Type
Lock
Rolling Shutter
H75H Euro Guide Bullet Pin Lock
Note 1.
A centre ground lock must be provided on shutters of greater than 5 metres width.
Certificate No: 131e to LPS 1175: Issue 6
Security Shutters Product Name Centurion
Model A305SS A305PS A305SA A305PA A305PG A310SS A315
Type Roller shutter with solid single skin steel lath Roller shutter with perforated single skin steel lath Roller shutter with solid single skin aluminium lath Roller shutter with punched aluminium lath Roller shutter with punched and glazed aluminium lath Roller shutter with solid single skin steel lath Roller shutter with reinforced double skin aluminium lath
Security Rating 1 1 1 1 1 2 3
Cert. No. 131e/01 131e/02 131e/03 131e/04 131e/05 131e/06 131e/07
Configurations, Sizes and Locking
20 Nov 2011
445
PART 4: SECTION 5.6 SECURITY SHUTTERS Models
Orientation Operation
A305SS A305PS A305SA A305PA A305PG
Reveal
A310SS
Reveal
Internal
Internal
A315
Reveal Internal
Minim um Maximum Minim um Maximum Locking Height Height Width Width (m) (m) (m) (m) Push up 1 3 1 3 Hopkins H75 pin lock fitted to internal or external face Tube motor 1 7 1 7 Hopkins H75 pin lock fitted to internal or external face Push up 1 3 1 3 Hopkins H75 pin lock fitted to internal face Tube motor 1 7 1 7 Hopkins H75 pin lock fitted to internal face Direct drive 1 7 1 7 Hopkins H75 pin lock fitted to internal face Push up 1 3 1 3 Hopkins H75 pin lock fitted to internal or external face Tube motor 1 7 1 7 Hopkins H75 pin lock fitted to internal or external face Push up 1 3 1 3 Hopkins H75 pin lock fitted to internal face Tube motor 1 7 1 7 Hopkins H75 pin lock fitted to internal face Direct drive 1 7 1 7 Hopkins H75 pin lock fitted to internal face Tube motor 1 7 2 7 Hopkins H75 pin lock fitted to internal face Tube motor 1 7 2 7 Hopkins H75 pin lock fitted to internal face Direct drive 1 7 2 7 Hopkins H75 pin lock fitted to internal face
Note: 1. The approval applies to the shutters when installed strictly in accordance with the instructions provided with the product.
Shellcast Systems Limited Camel House, Six Ashes, Bridgnorth WV15 6ER, United Kingdom Tel: +44 (0)1562 750 700 • Fax: +44(0)8712 453 553 E-mail: [email protected] • Website: www.shellcast-shutters.co.uk Certificate No: 707a to LPS 1175: Issue 5
Security Shutters Product Name
Model
Type
Linframe
CD38.1
Built-in rolling shutter Built-in rolling shutter Built-in rolling shutter Built-in rolling shutter Built-in rolling shutter Built-in rolling shutter Built-in rolling shutter
CD38.2 CD38.3 CD38/P.1 CD38/S.1 CD60.1 CD60.2
Minimum Clear Opening Height (m) 0
Minimum Clear Opening Width (m) 0.4
Maximum Clear Opening Height (m) 6
Maximum Clear Opening Width (m) 5
Security Rating
Cert. No.
1
707a/01
0
0.4
6
5
2
707a/02
(2)
707a/03
0
0.4
6
5
3
0
0.4
6
3
1
707a/04
0
0.4
6
3
1
707a/05
0
0.4
6
5
1
707a/06
0
0.4
6
5
2
707a/07
Notes
446
20 Nov 2011
PART 4: SECTION 5.6 SECURITY SHUTTERS 1. 2.
The approval applies to the shutters when installed strictly in accordance with the instructions provided with the product To achieve this grade the lockable override cover plate must be fitted and locked, and the key removed to a secure location.
SWS UK Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411 E-mail: [email protected] • Website: www.swsuk.co.uk Certificate No: 390a to LPS 1175: Issue 5.3
Security Shutters Product Name
Type
Lath
Minimum Width (m) 0.9
Maximum Height (m) 4.7
Maximum Width (m) 6
Security Rating
Cert. No.
Solid
Minimum Height (m) 0.6
SeceuroShield 7501 SeceuroShield 3801 SeceuroVision 7501
Roller shutter Roller shutter Roller shutter
1
390a/04
Solid
0.9
0.9
4
3
1
390a/02
Perforated
0.6
0.9
4.7
6
1
390a/05
Compatible Locking Devices and Method of Shutter Operation
LPCB Ref.No.
Product Name
Type
390a/02
SeceuroShield 3801
Roller shutter
390a/04
SeceuroShield 7501
Roller shutter
Operation Motorised Manual
390a/05
SeceuroVis ion 7501
Roller shutter
Lock Simbac Hopkins 6C3.3227 H75 pin cylinder lock lock
1
1
Approved Accessories
Accessory
Associated Products (LPCB Ref. No. 390a/..)
Manual override handle
022
04
05
Approved Installation Configurations3
LPCB Ref. No.
Product Name
Configuration Brick
390a/02
SeceuroShield 3801
390a/04
SeceuroShield 7501
390a/05
SeceuroVis ion 7501
20 Nov 2011
Reveal Internal face fixed External face fixed Reveal Internal face fixed Reveal Internal face fixed
Substrate Concrete Structural Steel
Structural Timber
447
PART 4: SECTION 5.6 SECURITY SHUTTERS Notes 1. 2. 3.
448
The Hopkins H75 pin lock is only approved on shutters over 3m wide operated by a motor drive axle. The manual override option is only approved on internally face fixed units with internally face fixed motor boxes. This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard.
20 Nov 2011
PART 4: SECTION 5.7 PERFORATED SECURITY SCREENS
Perforated security screens (otherwise referred to as security screens and void protection screens) listed in this section are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. In addition to approving security screens to LPS 1175, LPCB also offer security performance approval of such products to EN1627.
SWS UK Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411 E-mail: [email protected] • Website: www.swsuk.co.uk Certificate No: 390c/01 to LPS 1175: Issue 6
Perforated Security Screens Product Name
Type
SeceuroMesh
Fixed security screen
Minimum Height (m) 0.25
Minimum Width (m) 0.25
Maximum Height (m) 2.54
Maximum Width (m) 1.29
Security Rating
Cert. No.
1
390c/01
Approved Installation Configurations(1)
Configuration Structural Steel
External face Reveal
Substrate Concrete Brick Blockwork
Timber
Note 1.
This assumes installation direct to substrate and not via intermediate substrates.
Trellicor (Pty) Limited 20 Aberdare Drive, Phoenix Industrial Park, Durban, South Africa Tel: +27 31 500 4301 • Fax: +27 31 507 2129/3973 Certificate No: 474a to LPS 1175: Issue 5
Perforated Security Screens Product Name
Model
Type
Griffinguard
Standard
Griffinguard (3)
Double
Fixed security screen Fixed security screen
Minimum Height (m) 0.4
Minimum Width (m) 0.4
Maximum Height (m) 1.3
Maximum Width (m) 2.5
Security Rating
Cert. No.
1
474a/03
0.4
1.4
2.6
2.5
1
Note 1.
The Griffinguard is approved for either externally face fixing or reveal mounting into brickwork, lightweight blockwork, concrete blockwork, structural steelwork or timber.
20 Nov 2011
449
PART 4: SECTION 5.8 LOUVRE VENTS
Louvre vents listed within this section have been evaluated in accordance with LPS 1175 Specification for testing and classifying the burglary resistance of building components, strongpoints and security enclosures.
Stafford Bridge Doors Limited Bedford Road, Pavenham, Bedford MK43 7PS, United Kingdom Tel: +44 (0)1234 826316 • Fax: +44 (0)1234 826319 E-mail: [email protected] • Website: www.surelockmcgillgroup.com/sbd Certificate No: 516b to LPS 1175: Issue 7
Louvre Vents Product Name
Type
SR4 Louvre
Steel security louvre vent
Minimum Louvre Height1 (m) 0.35
Maximum Louvre Height1 (m) 2.5
Minimum Louvre Width2 (m) 0.35
Maximum Louvre Width2 (m) 1.15
Security Rating
Cert. No.
4
516b/01
Compatible Substrates3
Cert. No.
Substrate
516b/01
Steelw ork Reinforced blockw ork Reinforced concrete Partition w all of ‘Wilton’ / ‘Halton’ construction via Sapele timber stud4 Partition w all of equivalent resistance to LPS 1175 SR4 via Sapele timber stud4 lining an aperture in steelw ork, reinforced blockw ork or reinforced concrete
Notes: 1. The height of the louvre vent is measured perpendicular to the plane of the louvre blades. 2. The width of the louvre vent is measured in the plane of the louvre blades. 3. The vents are approved for installation in accordance with the instructions contained in documents D11767.15 (revision I) and D11767.23 (revision B). 4. Sapele timber stud should be at least 100 mm by 70 mm.
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Certificate No: 450h to LPS 1175: Issue 6
Louvre Vents Product Name
Type
Louvre Vent
Modular louvre vent system1
Minimum Louvre Module Height (m) 0.2
Maximum Louvre Module Height (m) 11
Minimum Louvre Module Width (m) 0.6
Maximum Louvre Module Width (m) 1.21
Security Rating
Cert. No.
5
450h/01
Compatible Substrates
LPCB Ref. No. 450h/01
Trade Name
Type
Installation method
Louvre Vent
Modular louvre vent system
Reveal fitting only
Compatible Substrates Reinforced Concrete Steelwork
Notes
450
20 Nov 2011
PART 4: SECTION 5.8 LOUVRE VENTS 1. 2.
The louvre modules can be bolted together to form a larger panel. The bolted together panels can theoretically fill any structural opening larger than the smallest module. The Louvre Vent may also be fitted directly above the Technocover Sentinel UltraSecure doorsets listed on LPCB certificate 450f without compromising their Security Ratings to LPS 1175.
20 Nov 2011
451
PART 4: SECTION 5.9 GARAGE DOORS
Theft of equipment from garages is fairly common due to the value of equipment often stored within them and the ease with which burglars can overcome many garage doors. Burglars also target garages that provide access to the inside of the house via internal pedestrian doors because the burglars can: attack the internal doorset unobserved by people in surrounding properties; and/or use tools stored within the garage to aid their entry into the house. Specifying garage doors that provide proven levels of resistance to forced entry therefore plays an important part in reducing: Theft of equipment from garages. Theft of items from houses resulting from entry through adjoining garages. Good physical security will also help to protect against attempted arson, especially if the garage doors have dual security and fire approval through LPCB. Garage doors listed in this section meet the requirements of LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. In addition to fitting garage doors approved to LPS 1175, specifiers keen to improve the security of their garages should also consider using security enclosures approved to LPS 1175 and fitting intruder detection equipment approved by LPCB and installed by a competent installer. Please refer to Section 4 for a list of approved security enclosures and Section 1 for a list of approved intruder detection equipment. LPCB also offer security performance approvals of garage doors to EN1627.
Aluroll Limited Mile Oak Industrial Estate, Maesbury Road, Oswestry, Shropshire SY10 8GA, United Kingdom Tel: +44 (0)800 977 8975 • Fax: +44 (0)1691 671 482 E-mail: [email protected] • Website: www.aluroll.co.uk Certificate No: 931a to LPS 1175: Issue 6
Garage Doors Product Name
Type
Elite
Internally face fitted double skin insulated roller shutter
Minimum Structural Opening Height (m) 0.9
Maximum Structural Opening Height (m) 5.2
Minimum Structural Opening Width (m) 0.9
Maximum Structural Opening Width (m) 5.0
Maximum Door Area (m2 ) 20
Compatible Locking Devices
Security Rating
Cert. No.
B
1
931a/02
Notes
1 The Elite garage door is also marketed as a T77 Elite roller shutter. That is available over the same size range and with same locking devices. 2 Refer to Volume 2 Part 4 Section 5.6 for full details of the locking systems and accessories approved on the T77 Elite roller shutter and other approved roller shutters manufactured by Aluroll Limited.
452
20 Nov 2011
PART 4: SECTION 5.9 GARAGE DOORS
SWS UK Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411 E-mail: [email protected] • Website: www.swsuk.co.uk Certificate No: 390b to LPS 1175: Issue 5.3
Garage Doors Product Name
Type
SeceuroGlide Excel
Garage door
Minimum Height (m) 1
Minimum Width (m) 1.5
Maximum Height (m) 3.85
Maximum Width (m) 5.2
Security Rating
Cert. No.
1
390b/01
Approved Accessories
Accessory
Associated Products (LPCB Ref. No. 390b/...)
Bullet locks
01
Approved Installation Configurations
Configuration
Substrate
Reveal 1 Internal face fixed
1
Brick
Blockwork
Structural Steel
Structural Timber
Notes 1. 2.
This assumes installation direct to substrate and not via intermediate substrates, such as plasterboard. No assessment has been made of the remote control device.
20 Nov 2011
453
PART 4: SECTION 6 ACCESS COVERS AND HATCHES
Many important facilities, especially those of utility companies, are unmanned and remote from the main business. At the request of the utility companies, access covers protecting items such as valves, switchgear and meters are now security rated to provide protection against malicious attack. LPCB approves access covers to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. The approval procedures and conditions that apply to access covers are the same as those that apply to security doors and shutters. It is important that specifiers only select access covers that are covered by the scope detailed on the certificate since products that fall outside that scope may not provide an equivalent level of security. It is also important to ensure that the products are installed in accordance with the manufacturer’s instructions and that all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly checked to ensure that they are in good condition and that they have not been tampered with. Products that have been certified by LPCB should be marked with a label indicating the grade of security offered, LPCB approval mark and certificate number.
Aquacast (Fabrications) Limited Unit 3 Power Park, Towers Business Park, Rugeley, Staffordshire WS15 1UZ, United Kingdom Tel: +44 (0)1889 572620 • Fax: +44 (0)1889 572629 E-mail: [email protected] • Website: www.aquacastltd.com Certificate No: 1020a to LPS 1175: Issue 7
Horizontal Access Cover Product Name
Type
Aquaguard
Single leaf horizontal access cover
Minimum Length of Internal Opening (mm) 250
Maximum Length of Internal Opening (mm) 1200
Minimum Width of Internal Opening (mm) 250
Maximum Width of Internal Opening (mm) 1200
Security Rating
Cert. No.
4
1020a/01
Compatible Padlocks1,2
Padlock
Cylinder
LPCB Cert. No. 1020a/01
Abloy PL340/25
Abloy Protec
Abloy PL340/25
Abloy High Profile
Abloy PL340/25
Abloy Disklock Pro
Abloy PL340/25
Abloy Exec
Abloy PL342
Abloy Protec
Abloy PL342
Abloy High Profile
Abloy PL342
Abloy Disklock Pro
Abloy PL342
Abloy Exec
Abloy PL350/25
Abloy Protec
Abloy PL350/25
Abloy High Profile
Abloy PL350/25
Abloy Disklock Pro
Abloy PL350/25
Abloy Exec
Accessories1
454
20 Nov 2011
PART 4: SECTION 6 ACCESS COVERS AND HATCHES Accessory
Code
LPCB Cert. No. 1020a/01
Alarm bracket
AB1
Cable holes 3
CH1
Extended frame and lid
EX1
Ladder type safety grill
FP1
Split type safety grill
FP2
Extended low er shroud4
LS1
Notes: 1. Certification does not cover the use of padlocks or accessories other than those listed. Utilisation of unlisted padlocks and/or accessories may affect the level of security offered by the access cover. 2. The ‘user friendliness’ of employing the padlocks listed has not been assessed as this is beyond the scope of LPS 1175: Issue 7. 3. Cable holes (accessory CH1) are only available on access covers with the extended frame and lid (accessory EX1). 4. The extended lower shroud (accessory LS1) must be used when the substrate onto which the access cover is mounted does not extend horizontally from the front of the main body of the access cover by at least 300 mm. 5. The access cover is approved when installed in accordance with the instructions on document AG-LPS4-Fit (Revision 3, dated 2 March 2011).
Midas Technologies (GB) Limited Unit A, Roundhouse Close, Eastern Industry, Peterborough PE1 5TA, United Kingdom Tel: +44 (0)1733 342600 • Fax: +44 (0)1733 346672 E-mail: [email protected] • Website: www.midastech.co.uk Certificate No: 421a to LPS 1175: Issue 5
Horizontal Access Covers Product Name
Type
Aquavent 2004 Aquavent 2004/TC Aquavent 2004/DC
Single leaf horizontal access cover Single leaf (twin lid1) horizontal access cover Double leaf horizontal access cover
Minimum Internal Opening Length (mm) 200 200
Maximum Internal Opening Length (mm) 1200 2000
Minimum Internal Opening Width (mm) 200 200
Maximum Internal Opening Width (mm) 1200 2000
Security Rating
Cert. No.
4 4
421a/01 421a/02
1200
4000
1200
2000
4
421a/03
Accessories
Accessory Safety grill/ladder Deep pan base frame Alarm bracket and switch plate
Access Covers (LPCB Ref. No. 421a/..) 01 02 03
Compatible Padlocks
20 Nov 2011
455
PART 4: SECTION 6 ACCESS COVERS AND HATCHES Padlock Designation
Cylinder
Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy
Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy Abloy
PL240/25 PL240/25EX PL240/25DP PL240/25PT PL242 PL242EX PL242DP PL242PT PL250/25 PL250/25EX PL250/25DP PL250/25PT PL340/25 PL340/25EX PL340/25DP PL340/25PT PL342 PL342EX PL342DP PL342PT PL350/25 PL350/25EX PL350/25DP PL350/25PT
Chubb 1K12c Chubb 1K13c Chubb 1K22c Chubb 1K23c ERA “Fortress” 977-91 Rotalok 60/12/ST Rotalok 60/12/SE Rotalocken 22RTLKNX
High Profile Exec Disklock Pro Protec High Profile Exec Disklock Pro Protec High Profile Exec Disklock Pro Protec High Profile Exec Disklock Pro Protec High Profile Exec Disklock Pro Protec High Profile Exec Disklock Pro Protec
Chubb 6-pin Chubb 6-pin Chubb 6-pin Chubb 6-pin ERA 6-pin N/A N/A Locken CL-PL2WR electronic cylinder
Access Covers (LPCB Ref. No. 421a/..) 01
02
03
Notes 1. 2. 3. 4.
This model incorporates a secondary inner lid. Certification does not cover the use of padlocks or accessories other than those listed above. Utilisation of unlisted padlocks and/or accessories may affect the level of security offered by the access cover. The 'user friendliness' of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS 1175: Issue 5. The resistance of the electronic cylinder to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175. Likewise, the assessment has not covered possible effects of any susceptibilities relating to the functionality and performance of the keys that may be used to operate the cylinder. It is therefore recommended that specifiers and installers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse and are resistant to any environmental conditions/interference that may cause the padlock to disengage.
Steelway Fensecure Limited t/a Steelway Brickhouse Brickhouse Lane, West Bromwich, West Midlands B70 0DY, United Kingdom Tel: +44 (0)121 521 4524 • Fax: +44 (0)121 521 4551 E-mail: [email protected] • Website: www.steelway.co.uk Certificate No: 645a to LPS 1175: Issue 5
456
20 Nov 2011
PART 4: SECTION 6 ACCESS COVERS AND HATCHES Horizontal Access Covers Product Name
Type
Sentry
Single leaf horizontal access cover Single leaf horizontal valve cover Single leaf horizontal ventilator cover Twin leaf in-line hinged horizontal access cover Twin leaf end-hinged horizontal access cover
Minimum Length of Internal Opening (mm) 300
Maximum Length of Internal Opening (mm) 1200
Minimum Width of Internal Opening (mm) 300
Maximum Width of Internal Opening (mm) 1100
Security Rating
Cert. No.
4
645a/01
200
300
200
300
4
645a/02
200
500
200
500
4
645a/03
1200
2200
600
1000
4
645a/04
1200
2200
600
1500
4
645a/05
Approved Accessories
Accessory Safety grid1 Safety grid/Exit support1 Alarm Bracket Junction box bracket External seal version External vent and seal version
Sentry Access Cover (LPCB Ref. No. 645a/…) 02 03 04 05
01
Compatible Padlocks
Padlock Designation
Cylinder
Abloy PL250/25 Abloy PL250/25EX Abloy PL250/25DP Abloy PL250/25PT Abloy PL350/25 Abloy PL350/25EX Abloy PL350/25DP Abloy PL350/25PT Chubb 1K23c Kaba KP15.0000C5-RB20 Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST
Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Chubb 6-pin Kaba 20 (Armoured)2 Abloy Exec Abloy Disklock Pro Abloy Protec Assa Twin-Combi Kaba 20 (Armoured)2 Kaba 20 (standard)2
Sentry Access Cover (LPCB Ref. No. 645a/…) 01 02 03 04 05
Notes 1. 2.
The safety grid/exit support is only available on access covers with an internal clear opening length of at least 400mm. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders.
20 Nov 2011
457
PART 4: SECTION 6 ACCESS COVERS AND HATCHES
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Certificate No: 450a to LPS 1175: Issue 5
Horizontal Access Covers Product Name
Type
Ultra Secure DV
Single leaf horizontal access cover8 Single leaf horizontal access cover8 Twin leaf horizontal access cover8 Twin leaf horizontal access cover8 Triple leaf horizontal access cover8 Triple leaf horizontal access cover8 Single leaf flush access cover Twin leaf flush access cover Triple leaf flush access cover Multiple leaf flush access cover
Ultra Secure DV (Small Lock) Ultra Secure DV4 Twin Leaf (End Hinged) Ultra Secure DV4 Twin Leaf (In-line Hinged) Ultra Secure DV4 Triple Leaf (In-line Hinged) Ultra Secure DV4 Triple Leaf (Special) SHH1/DV SHH2/DV SHH3/DV SHHM/DV
Minimum Internal Opening Length (mm) 150
Maximum Internal Opening Length (mm) 1100
Minimum Internal Opening Width (mm) 150
Maximum Internal Opening Width (mm) 1100
Security Rating
Cert. No.
4
450a/01
150
1100
150
1100
4
450a/02
1100
2200
1100
1800
4
450a/04
1100
2400
600
1100
4
450a/05
1800
3600
600
1100
4
450a/06
1800
3600
1100
1800
4
450a/07
400
1200
400
1200
3
450a/09
1200
2400
400
1200
3
450a/10
1500
3000
400
1200
3
450a/11
2000
120007
2000
2400
3
450a/12
Compatible Padlocks
Padlock Designation
Cylinder 01
Abloy PL240/25 Abloy PL240/25EX Abloy PL240/25DP Abloy PL240/25PT Abloy PL250/25 Abloy PL250/25EX Abloy PL250/25DP Abloy PL250/25PT Abloy PL340/25 Abloy PL340/25EX Abloy PL340/25DP Abloy PL340/25PT Abloy PL342/25 Abloy PL342/25EX Abloy PL342/25DP Abloy PL342/25PT Abloy PL350/25 Abloy PL350/25EX
458
Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec Abloy Disklock Pro Abloy Protec Abloy High Profile Abloy Exec
Access Covers (LPCB Ref. No. 450a/..) 02 04 05 06 07 09 10 11
12
20 Nov 2011
PART 4: SECTION 6 ACCESS COVERS AND HATCHES Abloy PL350/25DP Abloy PL350/25PT Chubb 1K22c Chubb 1K23c Kaba K20SS65L Kaba K20SS65CL Kaba KP15.0000C5-RB Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST Rotalok 60/12/ST
Abloy Disklock Pro Abloy Protec Chubb 6-pin Chubb 6-pin Kaba 20 (Armoured)4 Kaba 20 (Armoured)4 4 Kaba 20 (Armoured) Abloy Disclock Pro Abloy Exec Abloy Protec Assa Twin-Combi Kaba 20 (Armoured)4 Kaba 20 (Armoured)4
Accessories
Accessory F3 skirting frame K2 Hasp and staple Viper alarm bracket Ladder/safety grid 400 x 50 mm inner frame ventilation holes Standard vent option Maxi vent option Undercover bracing 'A15' option Undercover bracing 'B125' option Undercover bracing 'C250' option
01
Access Covers (LPCB Ref. No. 450a/..) 02 04 05 06 07 09 10 11
12
Notes 1. 2. 3. 4. 5. 6. 7. 8.
The Abloy PL240/25 and PL340/25 padlocks should only be used on Ultra Secure DV access covers that have been fitted with the K2 hasp and staple. The Abloy PL250/25, PL350/25 and Chubb 1K23c padlocks should not be used on Ultra Secure DV access covers that have been fitted with the K2 hasp and staple. If the Abloy PL250/25 and PL350/25 padlocks are to be fitted to access covers on upstands greater than 250 mm tall, the horizontal distance between the locking face of the access cover and the outside edge of the upstand must be at least 200 mm. The torque resistant version of the Kaba 20 cylinder must be fitted to these padlocks in place of the standard Kaba 20 cylinders. Certification does not cover the use of padlocks or accessories other than those listed above. Utilisation of unlisted padlocks and/or accessories may affect the level of security offered by the access cover. The 'user friendliness' of employing the padlocks listed above has not been assessed as this is beyond the scope of LPS 1175: Issue 5. The configurations of multi leaf access covers falling within the scope of this approval are defined on Technocover document SHH/DV/ASSY-08 dated 12 September 2006. This product is available with or without an inner lid. This does not effect the security rating of the product.
20 Nov 2011
459
PART 4: SECTION 7 SECURE WALLING SYSTEMS
Walling systems listed in this section are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing or intruder resistant building components, strongpoints, security enclosures and free-standing barriers. In order to comply with the terms of the approval, the walling systems must be designed and installed in accordance with the relevant system manuals noted within the product entry. Unless otherwise stated, the approvals cover: Plain systems (that is, excluding service penetrations, ducts or other openings such as doors and windows). Resistance to the creation of an access hole, within the area of the barrier, through which it is possible to pass the 225 mm by 400 mm elliptical test block defined in LPS 1175. It is recommended that evidence is sought to confirm compatibility of any doors, windows etc to ensure the combined assembly offers the required security rating. Where such compatibility has been proven, this is indicated in the relevant listing.
Isoclad Limited 10 Alder Road, West Chirton North Industrial Estate, North Shields, Tyne & Wear NE29 8SD, United Kingdom Tel: +44 (0)191 258 5052 • Fax: +44 (0)191 259 5742 E-mail: [email protected] • Website: www.isoclad.co.uk Certificate No: 142d to LPS 1175: Issue 6
Secure Partition Walling System Product Name Securiclad
Product Type Walls with horizontally laid panels Walls with vertically laid panels Walls with horizontally laid panels Walls with vertically laid panels
Minimum Height (m) 2.5
Maximum Height (m) Unlimited
Minimum Width (m) 2.5
Maximum Width (m) Unlimited
Security Rating 3
2.5
6.0
0.25
Unlimited
3
2.5
Unlimited
2.5
Unlimited
4
2.5
6.0
0.25
Unlimited
4
Cert. No. 142d/01
142d/02
System Components
Minim um Width (m ) 0.25
Maxim um Width (m ) 1.19
Ceiling panel (mineral w ool)
0.25
1.19
1
6
0.1
SR3/SR4 panel (PIR)
0.25
1.19
2.5
6
0.1
Ceiling panel (PIR)
0.25
1.19
1
6
0.1
Component Type
SR3/SR4 panel (mineral w ool)
Minim um Length (m ) 2.5
Maxim um Thickness (m) Length (m ) 6 0.1
Products Compatible with the Securiclad Security Panel System2,3
460
20 Nov 2011
PART 4: SECTION 7 SECURE WALLING SYSTEMS Manufacturer
Product Name
Product Type
Ascot Doors Limited
Centurion A363S
Single leaf outw ard opening doorset
Centurion A363D
Double leaf outw ard opening doorset
Benw eldSecure Bew dley doorset Pow ershield Doors Limited
Selectaglaze Limited Professional Barriers Limited Ascot Doors Limited
Single leaf outw ard opening doorset Pow ershield Class Single leaf outw ard 3 single opening doorset
852a/01
3
3
2 to 11, 13,16,17 and 19 2 to 11, 13,16,17 and 19 N/A
Pow ershield Class Double leaf outw ard 3 double opening doorset
852a/02
3
Series 55’ level 3’ Fixed light security w indow Extendor Eclipse Collapsible grille
683a/06
N/A
869a/01
3
33
N/A
Centurion A355
Single leaf outw ard opening doorset Single leaf outw ard opening doorset
131d/01
4
13
N/A
131d/02
4
N/A
Double leaf outw ard opening doorset
131d/03
4
Pow ershield Class Single leaf outw ard 4 single opening doorset
852a/03
4
13, 16, 19, 27, 29 and 31 13, 16, 19, 27, 29 and 31 3, 5, 7, 9, 10, 13, 16, 19, 20, 21, 22, 23, 24, 26, 28 and 30
Pow ershield Class Double leaf outw ard 4 double opening doorset
852a/04
4
Centurion A364S
Centurion A364D
Pow ershield Doors Limited
LPCB Security Compatible Locking Certificate Rating System s Num ber Active Leaf Passive Leaf 131d/04 3 12, 13, 15, N/A 16, 18 and 19 131d/05 3 12, 13, 15, 34, 35 and 16, 18 and 36 19 746a/01 3 1 N/A N/A
32
34, 35 and 36
3, 5, 7, 9, 10, 13, 16, 19, 20, 21, 22, 23, 24, 26, 28 and 30
N/A
32
Compatible Locking Systems for Products Compatible with the Securiclad Security Panel System
20 Nov 2011
461
PART 4: SECTION 7 SECURE WALLING SYSTEMS Com patible Model Locking System s 1 Assa 9787
Operation Entry
Single point mortice Key hook lock
2
MICO 942-3L EPC INT 3-w ay locking AD / HSCH 3 system w ith automatic deadlocking
3
MICO 942-3L EPC INT 3-w ay locking AD system w ith automatic deadlocking MICO 942-3 EPC INT 3-w ay locking system w ith manual MD / HSCH 3 deadlock
4
462
Type
3-w ay locking system w ith manual deadlock
Europrofile cylinder w ithin the HSCH 3 cylinder guard and lever handle None Europrofile cylinder (key:key)and lever handle Europrofile Europrofile cylinder w ithin cylinder the HSCH 3 (key:key) and cylinder guard panic exit push and lever handle plate None Europrofile cylinder (key:key) and panic exit push plate Europrofile Europrofile cylinder w ithin cylinder the HSCH 3 (key:key) and cylinder guard push pad and lever handle None Europrofile cylinder (key:key) and push pad Europrofile Europrofile cylinder w ithin cylinder the HSCH 3 (key:key) and cylinder guard lever handle and lever handle
5
MICO 942-3 EPC INT MD
6
MICO 942-3P EPC INT 3-w ay locking system w ith manual MD / HSCH 3 deadlock
7
MICO 942-3P EPC INT 3-w ay locking MD system w ith manual deadlock
8
MICO 942-3L EPC INT 3-w ay locking system w ith manual MD / HSCH 3 deadlock
9
None MICO 942-3L EPC INT 3-w ay locking system w ith manual MD deadlock
10
MICO 942-3L INT AD
3-w ay locking system w ith automatic deadlocking
Exit Key via an Assa 256 (Assa Classic) combined cylinder ring and thumbturn Europrofile cylinder (key:key) and lever handle
None
Europrofile cylinder (key:key) and lever handle Scandinavian oval cylinder and lever handle
Com patible Cylinders Q or R
A, B, C, D, E or F
-
A, B, C, D, E or F
-
A, B, C, D, E or F
-
A, B, C, D, E or F
-
-
20 Nov 2011
PART 4: SECTION 7 SECURE WALLING SYSTEMS 11
MICO 942-3 INT MD / HSCH 3
12
13
14 15
16
3-w ay locking Scandinavian system w ith manual oval cylinder deadlock w ithin the HSCH 3 cylinder guard and lever handle
Scandinavian oval cylinder and panic exit push plate Scandinavian Scandinavian MICO 942-3P INT MD / 3-w ay locking system w ith manual oval cylinder oval cylinder HSCH 3 deadlock w ithin the HSCH and push pad 3 cylinder guard and lever handle
MICO 942-3 INT MD
None 3-w ay locking system w ith manual deadlock
MICO 942-3P INT MD
None
18
3-w ay locking system w ith manual deadlock MICO 942-3L INT MD / 3-w ay locking system w ith manual HSCH 3 deadlock
19
MICO 942-3L INT MD
None
17
20
21
22
23
24 25
Scandinavian oval cylinder and panic exit push plate
3-w ay locking system w ith manual deadlock MICO 942-3L EPC INT 3-w ay locking AD / HSCH 4 system w ith automatic deadlocking
-
G, H, I, J, K, L, M, N or P G
Scandinavian oval cylinder and push pad G, H, I, J, K, L, Scandinavian Scandinavian M, N or P oval cylinder oval cylinder G w ithin the HSCH and lever handle 3 cylinder guard and lever handle
Europrofile cylinder w ithin the HSCH 4 cylinder guard and lever handle Europrofile MICO 942-3 EPC INT 3-w ay locking system w ith manual cylinder w ithin MD / HSCH 4 deadlock the HSCH 4 cylinder guard and lever handle MICO 942-3P EPC INT 3-w ay locking Europrofile system w ith manual cylinder w ithin MD / HSCH 4 deadlock the HSCH 4 cylinder guard and lever handle Europrofile MICO 942-3L EPC INT 3-w ay locking system w ith manual cylinder w ithin MD / HSCH 4 deadlock the HSCH 4 cylinder guard and lever handle MICO 942-3L INT AD / 3-w ay locking Scandinavian HSCH 4 system w ith oval cylinder automatic w ithin the HSCH deadlocking 4 cylinder guard and lever handle
20 Nov 2011
G, H, I, J, K, L, M, N or P G
Scandinavian oval cylinder and lever handle Europrofile cylinder (key:key) and lever handle
-
A, B, C, D, E or F
Europrofile cylinder (key:key) and panic exit push plate Europrofile cylinder (key:key) and push pad
A, B, C, D, E or F
Europrofile cylinder (key:key) and lever handle
A, B, C, D, E or F
A, B, C, D, E or F
G, H, I, J, K, L, Scandinavian M, N or P oval cylinder G and lever handle
463
PART 4: SECTION 7 SECURE WALLING SYSTEMS 26
Scandinavian oval cylinder and panic exit push plate
G, H, I, J, K, L, M, N or P G
Scandinavian Scandinavian MICO 942-3P INT MD / 3-w ay locking system w ith manual oval cylinder oval cylinder HSCH 4 deadlock w ithin the HSCH and push pad 4 cylinder guard and lever handle
G, H, I, J, K, L, M, N or P G
MICO 942-3 INT MD / HSCH 4
27
28 29
Scandinavian 3-w ay locking system w ith manual oval cylinder deadlock w ithin the HSCH 4 cylinder guard and lever handle
31
Scandinavian MICO 942-3L INT MD / 3-w ay locking G, H, I, J, K, L, Scandinavian HSCH 4 system w ith manual oval cylinder M, N or P oval cylinder deadlock w ithin the HSCH and lever handle G 4 cylinder guard and lever handle
32
M0455
33
Extendor Eclipse CL03 w ith CL03 cylinder guard
34
MICO 942
35
MICO 942P
36
MICO 942L
30
Surface mounted barrel bolts -
2-w ay panic exit device 2-w ay emergency exit device 2-w ay emergency exit device
-
-
-
Europrofile cylinder w ithin the CL03 cylinder guard -
Key (w hen internal locking version only) Panic bar
-
-
Push pad
-
-
Lever handle
-
S, T or U
Compatible Cylinders for Products Compatible with the Securiclad Security Panel System
Cylinder Manufacturer Model Reference
Type
A
Abloy
Protec CY304
Double Europrofile cylinder (key:key)
B
Abloy
Disclock Pro CY304
Double Europrofile cylinder (key:key)
C
ASSA
Tw in 7622
Double Europrofile cylinder (key:key)
D
ASSA
C5822
Double Europrofile cylinder (key:key)
E
ASSA
4822
Double Europrofile cylinder (key:key)
F
Kaba
Quattro S Euro
Double Europrofile cylinder (key:key)
G
ASSA
4807
Half Scandinavian oval mechanical cylinder
H
ASSA
Tw in 7607
Half Scandinavian oval mechanical cylinder
I
ASSA
C5807
Half Scandinavian oval mechanical cylinder
J
ASSA
4407
Half Scandinavian oval mechanical cylinder
K
Abloy
Protec CY201PT
Half Scandinavian oval mechanical cylinder
L
Locken
CL-PL2WR
Half Scandinavian oval mechatronic cylinder
M
Kaba
Quattro S Oval
Half Scandinavian oval mechanical cylinder
N
Kaba
K20 Oval
Half Scandinavian oval mechanical cylinder
O
Abloy
Disclock Pro CY201DP Half Scandinavian oval mechanical cylinder
464
20 Nov 2011
PART 4: SECTION 7 SECURE WALLING SYSTEMS P
ASSA
4801
Half Scandinavian oval mechanical cylinder
Q
ASSA
C5801
Half Scandinavian oval mechanical cylinder
R
ASSA
C5803
Half Scandinavian oval mechanical cylinder
S
ASSA
dp4400
Single Europrofile cylinder (key)
T
CISA
AP3S
Single Europrofile cylinder (key)
U
Kaba
Quattro Plus
Single Europrofile cylinder (key)
Notes: 1. The Securiclad panel systems must be installed in accordance with the approved Securiclad design manual (ISO/SECG04/02/11) and compatible product list (ISO/SEC/DSP/15/9/10). 2. The Security Rating attributed to the compatible product must be at least that of the wall in which it is to be fitted. For example, a Security Rating 3 doorset shall not be used to form part of a Security Rating 4 wall. 3. Refer to notes contained within the relevant certificate/Red Book entries for these products for details of restrictions on their use.
Lowrey Contractors Limited 200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111 E-mail: [email protected] • Website: www.lowrey-contractors.co.uk Certificate No: 974c to LPS 1175: Issue 7
Secure Partitioning Systems Product Name
Product Type
Lowrey Level 1 Security Mesh Panel System
Partition formed from wall panels supported by existing adjacent walls1 Partition formed from wall and ceiling panels supported by existing adjacent walls1 Ceiling formed from ceiling panels Partition formed from wall panels supported by existing adjacent walls1 Partition formed from wall and ceiling panels supported by existing adjacent walls1 Ceiling formed from ceiling panels
Lowrey Level 2 Security Mesh Panel System
20 Nov 2011
Minimum Height (m) 0.52
Maximum Height (m) 3.8
Minimum Width (m)
Maximum Width (m)
Maximum Length (m) N/A
Security Rating
Cert. No.
Unlimited
Minimum Length (m) N/A
0.53
1
974c/01
0.614
3.91
0.53
Unlimited
0.5
4.0
1
N/A
N/A
0.5
Unlimited
0.5
4.0
1
0.52
3.8
0.53
Unlimited
N/A
N/A
2
0.614
3.91
0.53
Unlimited
0.5
4.0
2
N/A
N/A
0.5
Unlimited
0.5
4.0
2
974c/02
465
PART 4: SECTION 7 SECURE WALLING SYSTEMS Product Name
Product Type
Lowrey Level 3 Security Mesh Panel System
Partition formed from wall panels supported by existing adjacent walls1 Partition formed from wall and ceiling panels supported by existing adjacent walls1 Ceiling formed from ceiling panels
Minimum Height (m) 0.52
Maximum Height (m) 3.8
Minimum Width (m)
Maximum Width (m)
0.53
0.614
3.91
N/A
N/A
Maximum Length (m) N/A
Security Rating
Cert. No.
Unlimited
Minimum Length (m) N/A
3
974c/03
0.53
Unlimited
0.5
4.0
3
0.5
Unlimited
0.5
4.0
3
System Components
Com ponent
Type
Minim um Height (m ) 0.25
Maxim um Height (m ) 2.4
Minimum Width (m ) 0.5
Maximum Width (m ) 1.5
Minim um Length (m) N/A
Maximum Length (m) N/A
N/A
N/A
0.25
1.5
0.25
3.8
Wall panel
Mesh w all panel
Ceiling panel
Mesh ceiling panel
Support post
Support post for 0.5 3.8 0.215 0.215 N/A w alling system 270 degree corner 0.5 3.8 0.125 0.125 N/A post for w alling system 90 degree corner 0.5 3.8 0.11 0.11 N/A post for w alling system Single leaf outw ard Refer to ‘Low rey Level 1, 2 and 3’ single leaf mesh security doorsets Ref. No. 974a/01, 03 and 05) for scope of approval. opening doorset
Corner post
Doorsets 5
N/A N/A
N/A
(LPCB
Double leaf outw ard Refer to ‘Low rey Level 1, 2 and 3’ double leaf mesh security doorsets (LPCB Ref. No. 974a/02, 04 and 06) for scope of approval. opening doorset Notes: 1. The walling system can either be constructed as a straight walling system or incorporate 90 or 270 degree angles. This angle is measured between the attack faces of the two adjacent panels. 2. The minimum height of partitioning systems incorporating doorsets is 1.0 m. 3. The minimum width of walls incorporating doorsets is 0.63 m. 4. The minimum height of partitioning systems formed with a ceiling and incorporating doorsets is 1.1 m. 5. The doorsets are not designed to be fitted within the ceiling system 6. The partitioning system’s resistance relies on the supporting substrate offering compatible resistance to manual attack. 7. The Lowrey security mesh panel systems are approved when installed in accordance with the instructions detailed in Lowrey’s document E-INST003 (Issue 4). Certificate No: 974f to LPS 1175: Issue 7
Secure Partitioning Systems Product Name
Product Type
Lowrey Level 4 Security Solid Panel System
Partition formed from wall panels supported by existing adjacent walls1
466
Minimum Height (m) 0.52
Maximum Height (m) 3.8
Minimum Width (m)
Maximum Width (m)
0.53
Unlimited
Minimum Length (m) N/A
Maximum Length (m) N/A
Security Rating
Cert. No.
4
974f/01
20 Nov 2011
PART 4: SECTION 7 SECURE WALLING SYSTEMS Product Name
Product Type Partition formed from wall and ceiling panels supported by existing adjacent walls1 Ceiling formed from ceiling panels
Minimum Height (m) 0.614
Maximum Height (m) 3.91
Minimum Width (m)
Maximum Width (m)
0.53
N/A
N/A
0.5
Maximum Length (m) 4.0
Security Rating
Unlimited
Minimum Length (m) 0.5
Unlimited
0.5
4.0
4
Cert. No.
4
System Components
Com ponent
Type
Minimum Height (m ) 0.25
Maximum Height (m ) 2.4
Minimum Width (m ) 0.5
Maximum Width (m ) 1.5
Minim um Length (m) N/A
Maximum Length (m) N/A
Wall panel
Solid w all panel
Ceiling panel
Solid ceiling panel
N/A
N/A
0.25
1.5
0.25
3.8
Support post
Support post for w alling system 270 degree corner post for w alling system 90 degree corner post for w alling system Single leaf outw ard opening plain leaf doorset Double leaf outw ard opening plain leaf doorset
0.5
3.8
0.215
0.215
N/A
N/A
0.5
3.8
0.125
0.125
N/A
N/A
0.5
3.8
0.11
0.11
N/A
N/A
Corner post
Doorsets 6
Refer to ‘Low rey Level 4’ single leaf security doorsets (LPCB Ref. No. 974d/01) for scope of approval. Refer to ‘Low rey Level 4’ double leaf security doorsets (LPCB Ref. No. 974d/02) for scope of approval.
Notes: 1. The walling system can either be constructed as a straight walling system or incorporate 90 or 270 degree angles in the wall line. This angle is measured between the attack faces of the two adjacent panels. 2. The minimum height of partitioning systems incorporating doorsets is 1.0 m. 3. The minimum width of walls incorporating doorsets is 0.63 m. 4. The minimum height of partitioning systems formed with a ceiling and incorporating doorsets is 1.1 m. 5. The doorsets are not designed to be fitted within the ceiling system. 6. The partitioning system’s resistance relies on the supporting substrate offering compatible resistance to manual attack. 7. The Lowrey security solid panel systems are approved when installed in accordance with the instructions detailed in Lowrey’s document E-INST003 (Issue 4).
MultiSteel Limited MultiSteel House, 117-119 Brent Terrace, London NW2 1LL, United Kingdom Tel: +44 (0)20 8208 8300 • Fax: +44 (0)20 8208 8209 E-mail: [email protected] • Website: www.multisteel.co.uk Certificate No: 818b to LPS 1175: Issue 6
20 Nov 2011
467
PART 4: SECTION 7 SECURE WALLING SYSTEMS Modular Security Screen Product Name
Type
Multisteel 'Security Screen'
Modular security screen1 with access control doorset2, 3 Modular security screen1 with deadlocking doorset4 Modular security screen5
Minimum Structural Opening Height (m) 1.9
Maximum Structural Opening Height (m) 5
Minimum Structural Opening Width (m) 0.79
Maximum Structural Opening Width (m) 4
Security Rating
Cert. No.
1
818b/01
1.9
5
0.7
4
2
1.9
5
2
6
2
Notes
1. 2.
3. 4. 5.
The security screens are available with glazed and opaque panels. The access control system’s resistance to “non-mechanical” attack has not been assessed as it is outside the scope of LPS 1175. It is therefore recommended that specifiers satisfy themselves that the components used are resistant to any environmental conditions/interference that may cause the locking system to disengage. Refer to LPCB certificate number 818a for full details of the Multisteel ‘Mag Lock’ doorset (LPCB reference number 818a/01). Refer to LPCB certificate number 818a for full details of the Multisteel ‘3 Point Mul-T-Lock’ doorset (LPCB reference number 818a/02). This configuration does not incorporate any doorsets.
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Certificate No: 450k to LPS 1175: Issue 7
Secure Partitioning System Product Name
Product Type
Ultrasecure security mesh panel system
Walling system Ceiling system
Minimum Height (m) 0.501
Maximum Height (m) 6
Minimum Width (m) 0.502
Maximum Width (m) Unlimited
Minimum Length (m) N/A
Maximum Length (m) N/A
Security Rating
Cert. No.
3
450k/01
N/A
N/A
0.50
Unlimited
0.50
6
3
System Components
468
20 Nov 2011
PART 4: SECTION 7 SECURE WALLING SYSTEMS Component
Type
Minimum Maximum Minimum Maximum Minimum Maximum Height Height Width Width Length Length (m) (m) (m) (m) (m) (m) 0.50 6 0.25 1 N/A N/A
Wall panel
Mesh wall panel
Ceiling panel
Mesh ceiling panel
N/A
N/A
0.25
1
0.50
6
Support post
Support post for
0.46
5.91
0.165
0.165
N/A
N/A
0.50
6
0.13
0.13
N/A
N/A
Corner post Doorsets
walling system 3 Corner pos t for walling system 3 Single leaf outward opening doorset Double leaf outward opening doorset
Refer to Ultrasecure SCD1 mes h security doorset (LPCB Ref. No. 450j/01) for scope of approval 4. Refer to Ultrasecure SCD2 mes h security doorset (LPCB Ref. No. 450j/02) for scope of approval 4.
Notes 1. 2. 3. 4. 5. 6.
The minimum height of partitioning systems incorporating doorsets is 1.08 m. The minimum width of walls incorporating doorsets is 0.63 m. The walling system can either be constructed as a straight walling system or incorporate 270 degree angles in the wall line. This angle is measured between the attack faces of the two adjacent panels. The doorsets are not designed to be fitted within the ceiling system. The partitioning system’s resistance relies on the supporting substrate offering compatible resistance to manual attack. The Ultrasecure security cage system is approved when installed in accordance with the instructions detailed on document SCSDV-3-FIT-01 (Ref.B).
The Expanded Metal Company Limited P.O.Box 14, Longhill Industrial Estate (North), Hartlepool TS25 1PR, United Kingdom Tel: +44 (0)1429 867 388 • Fax: +44 (0)1429 867 355 E-mail: [email protected] • Website: www.expandedmetalfencing.co.uk Certificate No: 731b to LPS 1175: Issue 7
Secure Partition Wall Systems Product Name
Type
Securilath HD1 Standard Securilath HD1-PB
Partition wall system Partition wall system Partition wall system Partition wall system
Securilath MD1 Securilath HD1 Twin
Minimum Wall Height (m) 1.2
Maximum Wall Height (m) 3.0
Minimum Wall Width (m) 0.6
Maximum Wall Width (m) N/A1
Security Rating2
Cert. No.
2
731b/01
1.2
3.0
0.6
N/A1
1
731b/02
1.2
3.0
0.6
N/A1
1
731b/03
0.6
1
3
731b/04
1.2
3.0
N/A
Approved Configurations
20 Nov 2011
469
PART 4: SECTION 7 SECURE WALLING SYSTEMS System Securilath HD1 Standard
Layers Attack face
Timber stud
Non- Attack face Securilath HD1-PB
Attack face
Timber stud
Non- Attack face
Securilath MD1
Attack face
Timber stud
Non- Attack face Securilath HD1 Tw in
Attack face
Timber stud
Non- Attack face
Configuration 19 mm thick plyw ood fixed using 4.5 mm by 50 mm w oodscrew s at 300 mm centres. ‘HD1 Securilath’ mesh panels fixed to timber studs using 65 mm by 3.35 mm bright annular nails to BS1202 w ith R36 w ashers at maximum 400 mm centres. 75 mm by 50 mm softw ood frame w ith vertical studs at 600 mm centres. Noggins shall be at maximum 400 mm centres. Timber fixed w ith M8 by 80 mm screw s. 12 mm thick plasterboard fixed using bugle head dryw all screw fixings PN2 3.5 mm by 55 mm BZP at maximum 450 mm centres. 12 mm thick plasterboard fixed using bugle head dryw all screw fixings PN2 3.5 mm by 55 mm BZP at maximum 450 mm centres. ‘HD1 Securilath’ mesh panels fixed to timber studs using 65 mm by 3.35 mm bright annular nails to BS1202 w ith R36 w ashers at maximum 400 mm centres. 75 mm by 50 mm softw ood frame w ith vertical studs at 600 mm centres. Noggins shall be at maximum 400 mm centres. Timber fixed w ith M8 by 80 mm screw s. 12 mm thick plasterboard fixed using bugle head dryw all screw fixings PN2 3.5 mm by 55 mm BZP at maximum 450 mm centres. 19 mm thick plyw ood fixed using 4.5 mm by 50 mm w oodscrew s at 300 mm centres. ‘MD1 Securilath’ mesh panels fixed to timber studs using 65 mm by 3.35 mm bright annular nails to BS1202 w ith R36 w ashers at maximum 400 mm centres. 75 mm by 50 mm softw ood frame w ith vertical studs at 600 mm centres. Noggins shall be at maximum 400 mm centres. Timber fixed w ith M8 by 80 mm screw s. 12 mm thick plasterboard fixed using bugle head dryw all screw fixings PN2 3.5 mm by 55 mm BZP at maximum 450 mm centres. 19 mm thick plyw ood fixed using 4.5 mm by 50 mm w oodscrew s at 300 mm centres. ‘HD1 Securilath’ mesh panels fixed to timber studs using 65 mm by 3.35 mm bright annular nails to BS1202 w ith R36 w ashers at maximum 400 mm centres. 75 mm by 50 mm softw ood frame w ith vertical studs at 600 mm centres. Noggins shall be at maximum 400 mm centres. Timber fixed w ith M8 by 80 mm screw s. ‘HD1 Securilath’ mesh panels fixed to timber studs using 65 mm by 3.35 mm bright annular nails to BS1202 w ith R36 w ashers at maximum 400 mm centres. 19 mm thick plyw ood fixed using 4.5 mm by 50 mm w oodscrew s at 300 mm centres.
Approved Installation Instructions
Securilath Installation Guide IP90 LPCB Inst. Issue 6, April 2011
Securilath Installation Guide IP90 LPCB Inst. Issue 6, April 2011
Securilath Installation Guide IP90 LPCB Inst. Issue 6, April 2011
Securilath Installation Guide IP90 LPCB Inst. Issue 6, April 2011
Notes: 1. There is no restriction on the maximum width as long as the partition wall is constructed in a straight run and does not include any corners. 2. These systems are approved as plain partitions. Please refer to the introduction to the section on secure walling systems in Red Book Volume 2 for further information.
470
20 Nov 2011
PART 4: SECTION 8 SECURE ROOFING SYSTEMS
Roofing systems listed in this section are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. In order to comply with the terms of the approval, the roofing systems should be designed and installed in accordance with the relevant system manuals noted within the product entry. The styles of tile/panel included within the scope of approval, the range of roof pitches to which they can be fitted and the accessories that are covered by the scope of approval are also noted in each product entry.
Icopal S. A. Parc Industriel des Hauts Sarts, Rue de Hermee 186, Herstal, Belgium Tel: +32 4240 5151 • Fax: +32 4240 5199 E-mail: [email protected] • Website: www.decra.co.uk UK sales, marketing, distribution and technical enquiries: Decra Roofing Systems Limited, Unit 4, Crompton Fields, Crompton Way, Crawley, West Sussex RH10 9QB, United Kingdom Tel: +44 (0)1293 545058 • Fax: +44 (0)1293 562709 E-mail: [email protected] • Website: www.decra.co.uk
Certificate No: 834a to LPS 1175: Issue 5.3
Security Roof Tiling Systems Product Name
Overall Tile Size (mm) 1324 x 410 1290 x 360 1324 x 410 1324 x 410
Decra Classic Decra Stratos Decra Elegance Decra Plus
Tile Cover (mm) 1260 x 370 1230 x 320 1260 x 370 1260 x 368
Security Rating 1 1 1 1
Cert. No. 834a/01 834a/02 834a/03 834a/04
Approved Configurations
System
Roof pitch
Tile bond configurations Staggered Straight
Batten size to be used according to the maximum rafter spacing (mm) 450 600 900 1200 1500
Decra Classic Decra Stratos Decra Elegance Decra Plus
10° to 90°
38 x 25
50 x 25
50 x 50
50 x 50
50 x 65
10° to 90°
-
38 x 38
50 x 38
50 x 50
50 x 50
50 x 65
10° to 90°
38 x 25
50 x 25
50 x 50
50 x 50
50 x 65
10° to 90°
38 x 25
50 x 25
50 x 50
50 x 50
50 x 65
Approved Accessories
20 Nov 2011
471
PART 4: SECTION 8 SECURE ROOFING SYSTEMS Accessory Cloaked verge cap – Left hand Cloaked verge cap – Right hand Barge cover – Left hand Barge cover – Right hand Barge cover eaves closure – Left hand Barge cover eaves closure – Right hand Top course Decra Plus D box barge cap Decra Plus D ridge/hip sealing strip D ridge hip end closure unit D ridge D ridge end closure unit In-line air vent In-line soil/mech extract vent Universal D ridge/hip ventilator Decra Classic D ridge vent filler Finishing kit Fixing nails (6kg) pack Decra power tile fixing nails
Decra Classic DH_B2 DI_B2 DH_B1 DI_B1 DH_DE1
Decra Elegance EH_B2 EI_B2 -
Decra Stratos SH_B1 SI_B1 SH_DE1
Decra Plus -
DI_DE1
-
SI_DE1
-
DC_B1 -
EC_B1 -
DC_B1 -
DC_B1 PH_D1 PSXD1
DD_DH1 DD_B1 DD_DE1 DVA_W1 DVS_W1 DVUXW1 DVRXW1 DU_B1 DNXB5 DNXP7
ED_DH1 ED_B1 ED_DE1 EVA_W1 EVS_W1 DVUXW1 DVRXW1 EU_B1 DNXB5 DNXP7
DD_DH1 DD_B1 DD_DE1 SVA_W1 SVS_W1 DVUXW1 DU_B1 DNXB5 DNXP7
DD_DH1 PD_D1 DD_DE1 DVA_W1 DVS_W1 DVUXW1 DU_B1 DNXB5 -
Approved System Instructions This approval covers the above roof tiling systems when designed and installed in accordance with the following instructions.
System Decra Classic
Instructions Decra Classic tile Secured by Design instructions (October 2007)
Decra Stratos
Decra Stratos tile Secured by Design instructions (October 2007)
Decra Elegance
Decra Elegance tile Secured by Design instructions (October 2007)
Decra Plus
Decra Plus tile Secured by Design instructions (October 2007)
Notes 1. 2.
472
This approval assumes the roofing systems are installed to roof structures of equivalent resistance to attack. This approval covers the roofing systems when installed in the ‘unsupported underlay’ configuration.
20 Nov 2011
PART 4: SECTION 9 PERIMETER SECURITY PRODUCTS
This section lists perimeter security products; such as fences, gates and turnstiles; that have been approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. While previous versions of the standard specified six levels of resistance (security ratings), the latest version (Issue 6 and 7) specifies eight security ratings. The levels of risk on which the security ratings are based in Issue 6 and 7 are represented in the following chart. HIGH RISK
LPS 1175 SR 8 LPS 1175 SR 7 LPS 1175 SR 6 LPS 1175 SR 5 LPS 1175 SR 4 LPS 1175 SR 3
LOW RISK
Products certified to this standard provide 20 minutes of resistance to extreme means of attempting forced entry into higher value storage areas. Products certified to these standards provide 10 minutes of resistance to professional means of attempting forced entry into higher value storage areas using a wide range of tools including mains powered tools. Products certified to these standards resist experienced attempts at forced entry using a wide range of tools including battery powered tools lasting up to 10 minutes (SR 4 and 5) or 5 minutes (SR 3).
LPS 1175 SR 2
Products certified to this standard provide 3 minutes of resistance to determined attack by an opportunist burglar using a range of techniques including those that involve creation of noise.
LPS 1175 SR 1
Products certified to this standard provide 1 minute of resistance to opportunist attempts at entry using a range of techniques including those that create noise such as those involving breaking glass.
LPS 1175 supports the assessment, approval and specification of perimeter security products such as walls, fences, gates and turnstiles. Unlike current British and European fence standards, LPS 1175 is based on manual attack testing with the resistance provided by the products measured in terms of the attack tools and time available to the attacker. It enables specifiers to select products according to their performance relative to the risks faced rather than simply specifying them by design. Although the standard includes minimum requirements relating to the height of the product, the product’s resistance to scaling is not covered by the standard, nor is its resistance to tunnelling or vehicle impact. Further information on the security rating system and attack tools can be found in the standard itself, which can be downloaded from the Red Book web site www.RedBookLive.com. For details of products offering resistance to vehicle impact, please refer to Section 2.10. Product Selection When selecting a perimeter security product, it is important to note aspects such as the size, locking systems and directions of opening; all can affect the level of security provided by the product. These aspects of each certified product have therefore been described to enable selection of the most appropriate product. It is important to ensure that the products are installed in accordance with the manufacturer’s instructions and that all exposed fixings, the substrate into which the device is fitted and the locking mechanisms are regularly checked to ensure that they are in good condition and that they have not been tampered with.
20 Nov 2011
473
PART 4: SECTION 9 PERIMETER SECURITY PRODUCTS
Unless otherwise stated, the security ratings attributed to the products listed require all locks to be fully engaged.
474
20 Nov 2011
PART 4: SECTION 9.1 SECURITY FENCING
CLD Fencing Systems Unit 11, Springvale Business Centre, Millbuck Way, Sandbach, Cheshire CW11 3HY, United Kingdom Tel: +44 (0)1270 764751 • Fax: +44 (0)1270 757503 E-mail: [email protected] • Website: www.cld-fencing.com Certificate No: 999a to LPS 1175: Issue 7
Security Fencing Systems Product Name
Type
Nominal Height (m)
Securus SR1
Welded mesh security fencing system1
2.4
Maximum Post Centres (m) 2.515
Securus SR2
Vertical bar and mesh panel security fencing system2
2.4
2.515
Gradients
Angles in Fence Line
Security Rating
Cert. No.
0°, 9.5° and 18.4°4
100° to 170°, 180°, 190° to 260°, 270° 100° to 170°, 180°, 190° to 260°, 270°
1
999a/01
2
999a/02
0°, 9.5° and 18.4°
Principle Components5
Com ponent
Type
Description
Securus Fencing System SR2
SR1
Base-plated posts
Primary posts
Pow der coated steel posts.
Corner posts
Embedded posts
Primary posts
Pow der coated steel posts used to form angles in the fence line. Pow der coated steel posts.
Panels Clamping bars
Reinforcing channels
Intermediate posts Pow der coated steel intermediate posts. Corner posts Pow der coated steel posts used to form angles in the fence line. Galvanised mesh ‘Security 358’ w elded mesh panels panels. Clamp bars Clamping bars secured over the mesh to the attack face of each post. Intermediate clamp Clamping bars secured over bars the mesh to the attack face of each intermediate post. Channel Channels secured over the mesh to reinforce it.
Base-Plated Version
Em bedded Version
Embedded Version
100° to 170° 190° to 260° 270°
One layer
100° to 170° 190° to 260° 270° One layer
100° to 170° 190° to 260° 270° Tw o layers
Approved Assembly and Installation Drawings
20 Nov 2011
475
PART 4: SECTION 9.1 SECURITY FENCING Docum ent Ref.
SR1/07/Bas (Draw ing 1 of SR1/07/Bas (Draw ing 2 of SR1/07/Bas (Draw ing 3 of SR1/07/Bas (Draw ing 4 of SR1/07/Bas (Draw ing 5 of SR1/07/Fou (Draw ing 1 of SR1/07/Fou (Draw ing 2 of SR1/07/Fou (Draw ing 3 of SR1/07/Fou (Draw ing 4 of SR1/07/Fou (Draw ing 5 of SR2/07/Fou (Draw ing 1 of SR2/07/Fou (Draw ing 2 of SR2/07/Fou (Draw ing 3 of SR2/07/Fou (Draw ing 4 of SR2/07/Fou (Draw ing 5 of
5) 5) 5) 5) 5) 5) 5) 5) 5) 5) 5) 5) 5) 5) 5)
Revision / Title / Contents Issue Date
Revision 7 12/01/11 Revision 7 12/01/11 Revision 7 12/01/11 Revision 7 12/01/11 Revision 7 12/01/11 Revision 6 06/12/10 Revision 6 06/12/10 Revision 6 06/12/10 Revision 6 06/12/10 Revision 6 06/12/10 Revision 5 13/12/10 Revision 5 13/12/10 Revision 5 13/12/10 Revision 5 13/12/10 Revision 5 13/12/10
General assembly
Securus Fencing System SR2
SR1 Base-Plated Version
Elevations detail
Installation instructions
Component details
Variable angle details
Em bedded Version
General assembly
Elevations detail
Installation instructions
Component details
Variable angle details
Embedded Version
General assembly
Elevations detail
Installation instructions
Component details
Variable angle details
Notes: 1. The fencing system is available in configurations to suit either surface mounting onto hard surfaces3 or embedding within concrete foundations placed in the ground3. 2. The fencing system is available in configurations to suit embedding within concrete foundations placed within the ground3 only. 3. It is important to ensure that the local ground onto/into which the fence is installed offers compatible strength and that the fence is installed in accordance with the documents listed in the table entitled ‘Approved assembly and installation drawings’. 4. The base-plated version of the ‘Securus SR1’ fencing system is not approved for use on 18.4° gradients. 5. The fencing system should only be constructed using components supplied by CLD Fencing Systems. 6. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two adjacent fence panels.
H S Jackson & Son (Fencing) Limited, t/a Jacksons Fencing Stowting Common, Ashford, Kent TN25 6BN, United Kingdom Tel: +44 (0)1233 750393 • Fax: +44 (0)1233 750178 E-mail: [email protected] • Website: www.jacksons-fencing.co.uk Certificate No: 913a to LPS 1175: Issue 6
Security Fencing System Product Name Jakoustic Class 3
476
Type
Height (m)
Timber security fencing system1
2.5, 2.75, 3.0 or 3.25
Post Centres (m) 0.125 to 2.4
Gradients 0° to 18.5°
Angles In Fence Line 90°, 180° or 270°
Security Rating 3
Cert. No. 913a/01
20 Nov 2011
PART 4: SECTION 9.1 SECURITY FENCING
Principle Components1
Component Timber Boards
Posts
Capping Rail Counter Rail Post Cover Boards Corner Supports Timberlok Screws
Type Description Timber acoustic boards – Mid section 142.75 mm by 34 mm by 4800 mm long timber tongue and groove board. Timber acoustic boards – Base 142.75 mm by 34 mm by 4800 mm long timber section tongued board. Timber acoustic boards – Top section 123 mm by 34 mm by 4800 mm long and /or 48 mm by 34 mm by 4800 mm long timber grooved board. Intermediate and corner posts 152 mm by 89 mm by 16 mm universal beam either 3350 mm, 3600 mm, 3850 mm or 4100 mm long to suit fence height. 100 mm by 50 mm timber batten either 2700 mm, Timber batten for steel post 2950 mm, 3200 mm or 3450 mm long to suit post height. Timber capping rail 145 mm by 34 mm by 4800 mm long timber section. Timber counter rail 70 mm by 34 mm by 2400 mm long timber section. Timber post cover board 125 mm by 34 mm by 3200 mm long timber board. Timber corner support 54 mm by 45 mm by 3200 mm long timber section. Steel screws 100 mm and 150 mm long galvanised steel screw.
Approved Assembly and Installation Drawings2, 3, 4
Document Ref. 09 HS1/1001 (Sheet 1 of 3) 09 HS1/1001 (Sheet 2 of 3) 09 HS1/1001 (Sheet 3 of 3)
Revision / Issue Date 0.1 05/01/10 0.1 05/01/10 0.1 05/01/10
Title / Contents Jakoustic Class 3 fencing general detail Jakoustic Class 3 fencing general detail Jakoustic Class 3 fencing raking detail
Notes 1. 2. 3. 4.
The fencing system should only be constructed using components supplied by Jacksons Fencing. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength and that the fence is installed in accordance with the documents listed the table entitled ‘Approved assembly and installation drawings’. The fencing system is approved for installation onto/into flat ground of gradients between 0° and 18.5°. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two adjacent fence posts.
Certificate No: 913b to LPS 1175: Issue 6
Security Fencing Systems Product Name
Type
Height (m)
Trident 4
Vertical bar and mesh panel security fencing system1 Vertical bar and mesh panel security fencing system1
3.6
Trident 5
4.2
Post Centres (m) 0.260 to 2.57 0.260 to 2.57
Gradients
Angles in Fence Line
Security Rating
Cert. No.
0° to 5.7°
90°, 180° or 270° 90°, 180° or 270°
4
913b/01
5
913b/02
0° to 5.7°
Principle Components1
20 Nov 2011
477
PART 4: SECTION 9.1 SECURITY FENCING Component Panels
Type Galvanised vertical bar and mesh panels
Posts
Galvanised steel posts
Description Fence panels comprising of reinforced 3/8” tubular vertical bars welded within 60 mm by 40 mm horizontal rails. The panels incorporate ‘358’ mesh panels welded on either face. 120 mm by 120 mm by 5 mm galvanised steel post.
Toppings
Concertina barbed tape topping
800 mm diameter barbed tape topping
Approved Assembly and Installation Drawings2, 3, 4
Document Ref.
09 HS1_1002 (Sheet 1 of 5) 09 HS1_1002 (Sheet 2 of 5) 09 HS1_1002 (Sheet 3 of 5) 09 HS1_1002 (Sheet 4 of 5) 09 HS1_1002 (Sheet 5 of 5) 09 HS1_1003 (Sheet 1 of 5) 09 HS1_1003 (Sheet 2 of 5) 09 HS1_1003 (Sheet 3 of 5) 09 HS1_1003 (Sheet 4 of 5) 09 HS1_1003 (Sheet 5 of 5) HS1_4001
Revision / Issue Date Revision 0.2 30/03/10 Revision 0.2 30/03/10 Revision 0.2 30/03/10 Revision 0.2 30/03/10 Revision 0.2 30/03/10 Revision 0 31/03/10 Revision 0 31/03/10 Revision 0 31/03/10 Revision 0 31/03/10 Revision 0 31/03/10 Revision 0.0 31/03/2010
Title / Contents
Product Name
3.6 m high Trident 4 fencing general layout
Trident 4
3.6m Trident 4 sections, details and notes
3.6m high Trident 4 fencing stepped using standard components 3.6m high Trident 4 fencing stepped using double posts 3.6m high Trident 4 fencing stepped using special stepped posts 4.2 m high Trident 5 fencing general layout
Trident 5
4.2 m Trident 5 sections, details and notes
4.2 m high Trident 5 fencing stepped using standard components 4.2m high Trident 5 fencing stepped using double posts 4.2m high Trident 5 fencing stepped using special stepped posts Concertina barbed tape topping option for trident fencing range
Notes 1. 2. 3. 4.
The fencing system should only be constructed using components supplied by Jacksons Fencing. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength and that the fence is installed in accordance with the documents listed the table entitled ‘Approved assembly and installation drawings’. The fencing system is approved for installation onto/into flat ground of gradients between 0° and 5.7°. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two adjacent fence posts.
Heras U.K. Fencing Systems Herons Way, Balby, Doncaster DN4 8WA, United Kingdom Tel: +44 (0)1302 364551 • Fax: +44 (0)1302 322401 E-mail: [email protected] • Website: www.heras.co.uk Certificate No: 890a to LPS 1175: Issue 6
Security Fencing Systems Product Name
Type
Height (m)
Contour Standard Capped
Railings
1.8, 2.0 and 2.4
478
Post Centres (m) 2.84
Gradients
Angles In Fence Line1
Security Rating
Cert. No.
16.5°3
75° to 105°, 165° to 195° and 255° to 265°
1
890a/01
20 Nov 2011
PART 4: SECTION 9.1 SECURITY FENCING Product Name
Type
Height (m)
Gradients
Angles In Fence Line1
Security Rating
Cert. No.
1.8, 2.0 and 2.4
Post Centres (m) 2.84
Contour Mitred Top
Railings
1.65°3
1
890a/02
Railings
1.8, 2.0 and 2.4
2.755
17°3
1
890a/03
Contour Security Mitred Top
Railings
1.8, 2.0 and 2.4
2.755
17°3
1
890a/04
Contour Fullered Top
Railings
1.8, 2.0 and 2.4
2.84
16.5°3
1
890a/05
Contour Point Top
Railings
1.8, 2.0 and 2.4
2.84
16.5°3
1
890a/06
Contour Square Bar Capped Top
Railings
1.8, 2.0 and 2.4
2.84
16.5°3
Pallas Xtra
Welded mesh security fencing system Welded mesh security fencing system
1.8, 2.0 and 2.4
2.53
0°2
1.8, 2.0, 2.4, 3.0, 4.2 and 5.2
2.44
0°2
75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 175° to 185° and 265° to 275° 175° to 185° and 265° to 275°
Contour Security Capped
Zenith
1
1
890a/08
1
890a/09
Principle Components (Contour Fencing Systems)4
Component Type
Description
Finials
Fullered finial Point top finial Fis hplate used to attach rails to intermediate pos ts. Thes e form angles in the fence between 165°
Fis hplates
Fullered Point Intermediate fis hplate
Corner fis hplate
and 195°1 Fis hplate used to attach rails to intermediate pos ts. Thes e form angles in the fence between 75° and 105° and between 255°
Fencing System Contour Contour Contour Contour Contour Contour Square Bar Standard Mitred Security Security Fullered Point Capped Top Top Capped Capped Mitred Top Top Top
and 265°1
20 Nov 2011
479
PART 4: SECTION 9.1 SECURITY FENCING Pales
Posts
Rails
25.5 mm (outer diameter) steel tubes at 0.125 mm centres Standard 25.5 mm (outer mitred pales diameter) steel tubes at 0.125 mm centres TR300 pales 25.5 mm (outer diameter) steel tubes at 0.125 mm centres 25.5 mm (outer Security diameter) steel capped tubes at pales 0.103 mm centres Security 25.5 mm (outer mitred pales diameter) steel tubes at 0.103 mm centres Square bar 25 mm by 25 mm steel capped tubes at pales 0.125 mm centres HD rolled HD rolled form ed form ed post of pos ts nom inal cross section 117 mm by 43.5 mm
HD1 rails
Standard capped pales
HD2 rails
HD3 rails
55 mm by 52 mm by 1.5 mm rail 55 mm by 52 mm by 1.5 mm rail 55 mm by 52 mm by 1.5 mm rail
Principle Components (Pallas Xtra and Zenith Fencing Systems)4
Component
Type
Panels
Pallas Xtra welded mesh panels
480
Description
Welded mes h formed from nominal 6 mm diameter steel vertical wires at 50 mm centres and pairs of 8 mm diameter horizontal wires at 200 mm centres Zenith welded mesh Welded mes h formed from nominal 4 mm diameter steel panels wires at 76.3 mm (3 inch) vertical centres and 12.7 mm (1/2 inch) horizontal centres
Fencing System Pallas Zenith Xtra
20 Nov 2011
PART 4: SECTION 9.1 SECURITY FENCING Panel clamp bars
Hexafix clamp bars Zenith clam p bars
Posts
Hexafix RHS intermediate posts Hexafix RHS corner posts Zenith interm ediate posts Zenith interm ediate posts Zenith interm ediate posts Zenith interm ediate posts Zenith corner pos ts Zenith corner pos ts Zenith corner pos ts
U clamp sets U- clamp set
40 mm by 5 mm slotted steel clamp bars secured using M8 by 40 mm shear drive bolts 40 mm by 5 mm slotted steel clamp bars secured using M8 cup square bolts and shear nuts 60 by 40 mm by 3 mm RHS pos ts with integral panel mounting clips 60 by 60 mm by 2 mm SHS posts with integral panel mounting clips 60 by 60 mm by 2 mm SHS posts for use on 1.8 m, 2.0 m and 2.4 m high fences 80 by 40 mm by 3 mm RHS pos ts for us e on 3.0 m high fences 80 by 80 mm by 3 mm RHS pos ts for us e on 4.2 m high fences 100 by 100 mm by 4 mm SHS posts for use on 5.2 m high fences 60 by 60 mm by 2 mm SHS posts for use on 1.8 m, 2.0 m and 2.4 m high fences 80 by 80 mm by 3 mm RHS pos ts for us e on 3.0 m and 4.2 m high fences 100 by 100 mm by 4 mm SHS posts for use on 5.2 m high fences Three U-clamp sets comprising 5 mm diameter steel Uclamps, plastic bases, steel retaining plates , M6 shear nuts and plastic covers
Approved Assembly and Installation Drawings (Contour, Pallas Xtra and Zenith Fencing Systems)5
Document Ref.
Revision / Title / Contents Issue Date
Form 39 Form 40 Form 42 (Contour Capped/ Mitred/ Square Bar) Form 42 (Contour Finial Top) Form 42 (Contour Security Capped/ Mitred Top)
20 Nov 2011
0 7/7/10 0 11/11/10 11/11/10
Cus tomer information (Zenith) Cus tomer information (Pallas Xtra) Cus tomer information (Contour Capped / Mitred / Square Bar)
11/11/10
Cus tomer information (Contour Point Top / Fullered Top) Cus tomer information (Contour Capped / Mitred / Square Bar)
11/11/10
Fencing System Pallas Xtra
Zenith
Contour Standard Capped and Contour Mitred Top
Contour Security Capped and Contour Security Mitred Top
Contour Square Bar Point Top Capped and Top Contour Fullered Top
481
PART 4: SECTION 9.1 SECURITY FENCING ref_pal_1
B 11/11/10
ref_pal_3
0 19/3/09
ref_zen_1
A 11/11/10
ref_zen_3
0 16/3/09
Pallas Xtra specification 1.8m, 2.0m, 2.4m high fence installation details
Hexafix system External corner assem bly Zenith system specification All heights Installation details Zenith system in ground spec corner arrangement
Notes 1.
The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two adjacent fence posts. The fencing system is only approved for installation into flat level ground. The gradient is based on a maximum rake of 800 mm along the length of the rail. It relates to the 2.0 m and 2.4 m high fences. The scope of approval for the 1.8 m high fences only covers fences installed on flat level ground. The fencing system should only be constructed using components supplied by Heras U.K. Fencing Systems. The fencing system is approved for installation into foundations buried in the ground, as detailed on the documents listed in the table above entitled ‘Approved Assembly and Installation Drawings’. The approval does not cover the use of base plated posts surface mounted on top of the ground. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength.
2. 3. 4. 5. 6.
NK Fencing Limited 40 Trailcock Road, Carrickfergus, Co. Antrim, Northern Ireland BT38 7NU, United Kingdom Tel: +44 (0)28 9335 1172 • Fax: +44 (0)28 9336 4336 E-mail: [email protected] • Website: www.nkfencing.com Certificate No: 951a to LPS 1175: Issue 6
Security Fencing Systems Product Name Ibex Hi Security
Type Welded mesh security fencing system
Height (m) 1.8 to 3
Post Centres (m) 1 to 2.46
Gradients 0° to 5.71°
Angles in Fence Line 90° to 315°
Security Rating 1
Cert. No. 951a/01
Principal Components
Component
Type
Panels
Pre-galvanized welded Galvanized welded mesh formed mesh panels from nominal 4 mm diameter steel vertical and horizontal wires at 76.2 mm and 12.7 mm centres respectively
482
Description
Ibex Hi Security Fencing System Base-plated Standard version (Embedded version)
20 Nov 2011
PART 4: SECTION 9.1 SECURITY FENCING Base-plated Posts NK Ibex Hi-Security standard post assembly NK Ibex Hi-Security end post assembly NK Ibex Hi-Security alternative end post assembly
NK Ibex Hi-Security corner post assembly Embedded Posts NK Ibex Hi-Security standard post assembly NK Ibex Hi-Security end post assembly
NK Ibex Hi-Security corner post assembly Panel clamping bars
Stretcher bar
Hot dip galvanized steel intermediate post Hot dip galvanized steel post
180°
Hot dip galvanized steel post used >90° to <180° to form the end of the fence line or >180° to <270° used in pairs to form acute and >270° to 315° obtuse angles in the fence line Hot dip galvanized steel post used to form right angles in the fence line
270°
Hot dip galvanized steel intermediate post
180°
Hot dip galvanized steel post used to form the end of the fence line or used in pairs to form acute and obtuse angles in the fence line
>90° to <180° >180° to <270° >270° to 315°
Hot dip galvanized steel post used to form right angles in the fence line Clamping bars secured to the attack face of each post
270°
Approved Assembly and Installation Drawings
Drawing No. / Sheet
Revision / Issue Date
1096M (Sheet 22) 1096M (Sheet 23)
18/08/09
1096M (Sheet 24)
18/08/09
1096M (Sheet 25)
Rev B 08/09/09
1096M (Sheet 26)
18/08/09
1096M (Sheet 27) 1096M (Sheet 28)
18/08/09
20 Nov 2011
Rev A 02/09/09
Rev A 08/09/09
Title / Contents
1.8-3.0 Ibex security fence (base plated posts) - Fence general arrangement 1.8-3.0 Ibex security fence (base plated posts) - Fence general arrangement for sloping ground (Option A - Panels above ground level)
Ibex Hi Security Fencing System Base-plated Standard version (Embedded version)
1.8-3.0 Ibex security fence (base plated posts) - Fence general arrangement for sloping ground (Option B - Buried panel bases) 1.8-3.0 Ibex security fence (base plated posts) - Fence erection details (Exploded views and sections at posts) 1.8-3.0 Ibex security fence (base plated posts) - Fence erection details (Plan views)
1.8-3.0 Ibex security fence (base plated posts) - Panel detail 1.8-3.0 Ibex security fence (base plated posts) - Post and stretcher bar detail
483
PART 4: SECTION 9.1 SECURITY FENCING
1096M (Sheet 29) 1096M (Sheet 30)
18/08/09
1096M (Sheet 31)
18/08/09
1096M (Sheet 32)
Rev B 08/09/09
1096M (Sheet 33) 1096M (Sheet 34) 1096M (Sheet 35)
18/08/09
Rev A 02/09/09
18/08/09 Rev A 02/09/09
1.8-3.0 Ibex security fence (buried posts) Fence general arrangement 1.8-3.0 Ibex security fence (buried posts) Fence general arrangement for sloping ground (Option A - Panels above ground level)
1.8-3.0 Ibex security fence (buried posts) Fence general arrangement for sloping ground (Option B - Buried panel bases) 1.8-3.0 Ibex security fence (buried posts) Fence erection details (Exploded views and sections at posts)
1.8-3.0 Ibex security fence (buried posts) Fence erection details (Plan views) 1.8-3.0 Ibex security fence (buried plated posts) - Panel detail 1.8-3.0 Ibex security fence (buried posts) Post and stretcher bar detail
Notes 1. 2.
The fencing system should only be constructed using components supplied by NK Fencing Limited. The fencing system is available in configurations to suit either surface mounting onto hard surfaces or embedding within concrete foundations placed in the ground. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength and that the fence is installed in accordance with the documents listed in the table above entitled ‘Approved Assembly and Installation Drawings’. The fencing system is approved for installation onto/into flat ground of gradients between 0° and 5.71°. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two adjacent fence panels.
3. 4. 5.
TangoRail Limited Units 1-3,, Prothero Industrial Estate, Bilport Lane, Wednesbury, West Midlands WS10 0NT, United Kingdom Tel: +44 (0)844 8360008 • Fax: +44 (0)844 8360009 E-mail: [email protected] • Website: www.tangorail.com Certificate No: 942a to LPS 1175: Issue 6
Security Fencing Systems Post Centres (m) 2.84
Gradients1
1.8, 2.0, 2.1 and 2.4
2.84
16.5°3
Railings
1.8, 2.0, 2.1 and 2.4
2.755
17°3
TangoRail TR250
Railings
1.8, 2.0, 2.1 and 2.4
2.755
17°3
TangoRail TR300F
Railings
1.8, 2.0, 2.1 and 2.4
2.84
16.5°3
TangoRail TR300P
Railings
1.8, 2.0, 2.1 and 2.4
2.84
16.5°3
TangoRail TR400
Railings
1.8, 2.0, 2.1 and 2.4
2.84
16.5°3
Product Name
Type
Height (m)
TangoRail TR100
Railings
1.8, 2.0, 2.1 and 2.4
TangoRail TR200
Railings
TangoRail TR150
484
16.5°3
Angles In Fence Line2 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265° 75° to 105°, 165° to 195° and 255° to 265°
Security Rating 1
Cert. No. 942a/01
1
942a/02
1
942a/03
1
942a/04
1
942a/05
1
942a/06
1
942a/07
20 Nov 2011
PART 4: SECTION 9.1 SECURITY FENCING Principle Components3
Component Type
Description
Finials
Fullered
Fullered finial
Point
Point top finial
TangoRail Fencing System TR100
Fis hplates
Intermediate Fishplate fis hplate used to attach rails to interm ediate posts. These form angles in the fence between 165° Corner fis hplate
20 Nov 2011
and 195°1 Fishplate used to attach rails to interm ediate posts. These form angles in the fence between 75° and 105° and between 255° and 265°1
TR200
TR150
TR250 TR300F TR300P TR400
485
PART 4: SECTION 9.1 SECURITY FENCING Pales
Standard capped pales
Standard mitred pales
TR300 pales
Security capped pales
Security mitred pales
Square bar capped pales
Posts
HD rolled form ed posts
Rails
HD1 rails
HD2 rails
HD3 rails
25.5 mm (outer diameter) steel tubes at 0.125 mm centres 25.5 mm (outer diameter) steel tubes at 0.125 mm centres 25.5 mm (outer diameter) steel tubes at 0.125 mm centres 25.5 mm (outer diameter) steel tubes at 0.103 mm centres 25.5 mm (outer diameter) steel tubes at 0.103 mm centres 25 mm by 25 mm steel tubes at 0.125 mm centres HD rolled formed pos t of nominal cross section 117 mm by 43.5 mm 55 mm by 52 mm by 1.5 mm rail 55 mm by 52 mm by 1.5 mm rail 55 mm by 52 mm by 1.5 mm rail
Approved Assembly and Installation Drawings4
486
20 Nov 2011
PART 4: SECTION 9.1 SECURITY FENCING Document Ref.
Revision / Title / Contents Issue Date
Form 42 (TangoRail TR100, TR200 and TR400) Form 42 (TangoRail TR150 and TR250)
11/11/10
Form 42 (TangoRail TR300F and TR300P)
11/11/10
11/11/10
Customer information (Contour Capped / Mitred / Square Bar) Customer information (Contour Capped / Mitred / Square Bar) Customer information (Contour Fullered Top / Point Top)
TangoRail Fencing System TR100
TR200
TR150
TR250 TR300F TR300P TR400
Notes 1. 2. 3. 4. 5.
The gradient is based on a maximum rake of 800 mm along the length of the rail. It relates to the 2.0 m and 2.4 m high fences. The scope of approval for the 1.8 m high fences only covers fences installed on flat level ground. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two adjacent fence posts. The fencing system should only be constructed using components supplied by TangoRail Limited. The fencing system is approved for installation into foundations buried in the ground, as detailed on the documents listed in the table above entitled ‘Approved Assembly and Installation Drawings’. The approval does not cover the use of base plated posts surface mounted on top of the ground. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength.
The Expanded Metal Company Limited P.O.Box 14, Longhill Industrial Estate (North), Hartlepool TS25 1PR, United Kingdom Tel: +44 (0)1429 867 388 • Fax: +44 (0)1429 867 355 E-mail: [email protected] • Website: www.expandedmetalfencing.co.uk Certificate No: 731c to LPS 1175: Issue 6
Security Fencing Systems Product Name 1576
Type Expanded metal mesh security fencing system
Height (m) 2.4
Maximum Post Centres (m) 3
Security Rating 2
Cert. No. 731c/01
Principal Components1
20 Nov 2011
487
PART 4: SECTION 9.1 SECURITY FENCING Component
Type
Description
Panels
Expamet 1576
Expanded metal mesh panels
Posts
2.4 1576 Inter Post
3.215 m long intermediate post to suit 2.4 m high fence 3.215 m long corner post to suit 2.4 m high fence Five stringers are located between each pair of adjacent posts on the non-attack side of the fence panel. 2.44 m long clamping strips secured to the attack face of each intermediate post. 2.44 m long ‘L’ section clamping plates secured to the attack face of each corner post.
2.4 1576 Corner Post Stringers
Diamond stringer
Clamping Strips
FCS 2440 Corner clamp plate
Notes 1. 2.
The fencing system should be constructed using components supplied by The Expanded Metal Company Limited. The fencing system is approved for installation onto flat level ground of compatible strength in accordance with the instructions contained in document ‘1576/INST’ (Rev. D, 2/4/09).
Certificate No: 731e to LPS 1175: Issue 7
Security Fencing System Product Name 1576 Class 3
Type Twin-skinned expanded metal mesh fencing system
Height (m) 2.465
Post Centres (m) 0.5 to 3.0
Gradients1 0°
Angles in Fence Line2 90°, 180° and 270°
Security Rating 3
Cert. No. 731e/01
Principle Components3
Com ponent
Type
Description
Posts
Intermediate posts (180°)
80 mm by 40 mm by 3 mm galvanised steel posts.
Corner posts (90° and 270°)
100 mm by 100 mm by 4 mm galvanised steel posts w ith 80 mm by 40 mm by 3 mm RHS boxes running up adjacent sides. 80 mm by 40 mm by 3 mm galvanised steel posts.
End posts Mid lugs End lugs
35 mm high by 150 mm long by 5 mm thick galvanised steel flats for use on intermediate posts (six per post). 35 mm high by 90 mm long by 5 mm thick galvanised steel flats for use on end posts and corner posts (six per post). 1576 expanded metal mesh panels 3.
Panels
Galvanised mesh panels
Horizontal rails
Diamond stringer
Clamping strips
Flat clamp strip
Six stringers are located betw een each pair of adjacent posts. These are sandw iched betw een the tw o mesh layers forming each fence panel. 40 mm w ide by 5 mm thick by 2465 mm long galvanised steel bar.
Corner clamp plate
149 mm w ide by 2 mm thick by 2465 mm long ‘L’ shaped galvanised steel bar.
Approved Assembly and Installation Drawings
Docum ent Reference 1576/C3/ILLUST 1576/C3/INST
Revision D 20/04/2011 E 20/04/2011
Title / Contents 1576 Fencing - Class 3 1576 Class 3 Fencing Installation
Notes: 1. The fencing system is approved for installation into flat ground of gradients 0°.
488
20 Nov 2011
PART 4: SECTION 9.1 SECURITY FENCING 2. The ‘angles in fence line’ define the range of angles covered by the scope. These are measured between the attack faces of two adjacent fence panels. 3. Mesh panels must be attached to the front and rear of the posts and stringers and overlap adjacent panels by at least 150 mm at intermediate posts. 4. The fencing system should only be constructed using components supplied by The Expanded Metal Company Limited. 5. The fencing system is only available for embedding into concrete foundations placed within the ground. 6. It is important to ensure the local ground onto/into which the fence is installed offers compatible strength and that the fence is installed in accordance with the documents listed in the table entitled ‘Approved Assembly and Installation Drawings’.
20 Nov 2011
489
PART 4: SECTION 9.2 SECURITY GATES
CLD Fencing Systems Unit 11, Springvale Business Centre, Millbuck Way, Sandbach, Cheshire CW11 3HY, United Kingdom Tel: +44 (0)1270 764751 • Fax: +44 (0)1270 757503 E-mail: [email protected] • Website: www.cld-fencing.com Certificate No: 999b to LPS1175: Issue 7
Security Gates Product Name Lockmaster
Type Single leaf inward opening security gate1 Double leaf inward opening security gate1
Height (m) 2.44
Minimum Width (m) 0.6
Maximum Width (m) 3
Security Rating 2
2.44
1.2
6
2
Cert. No. 999b/01
Compatible Locking Devices
Reference
Manufacturer
Model
1
Chubb
B-3C16-PL-802
2
Ingersoll
33
CLD Fencing Systems
London Line BSC110-CH2 Drop bolt
Type
Com patible operating devices
Mortice hook lock Mortice hook lock Drop bolt
External face
Internal face
Com patible cylinders
Key
Key
A and B
Key
Key
A and B
-
Handle
-
Compatible Cylinders
Reference
Manufacturer
Model
Type
A
Eurospec
CYA 74260PC
Euro-profile double cylinder (key:key)
B
Mul-T-Lock
Interactive
Euro-profile double cylinder (key:key)
Notes: 1. The gate is available in configurations to suit either surface mounting onto hard surfaces4 or embedding within concrete foundations placed in the ground4. 2. Fitted with an LS2 cylinder guard supplied by Tindall Engineering Limited. 3. This option is only available on double leaf gates. The security rating noted above will only be achieved if the primary locking device (i.e. those referenced as ‘1’ and ‘2’ in the compatible locking devices table) is engaged. 4. It is important to ensure that the local ground onto/into which the gate is installed offers compatible strength. 5. The gap between the gate posts and adjacent structures must not exceed 220 mm. 6. The gap between the bottom of the gate leaf and the ground must not exceed 50 mm.
The Expanded Metal Company Limited P.O.Box 14, Longhill Industrial Estate (North), Hartlepool TS25 1PR, United Kingdom Tel: +44 (0)1429 867 388 • Fax: +44 (0)1429 867 355 E-mail: [email protected] • Website: www.expandedmetalfencing.co.uk Certificate No: 731a to LPS 1175: Issue 5
Vehicle and Pedestrian Gates Product Name Alleygator ™
Type
Width (mm)
Pedestrian alley gate
810, 1000, 1100 and 1600 2150, 2300, 2450, 3010 and 3300
Vehicle alley gate
490
Height (mm) 2350
Security Rating 1
Cert. No. 731a/01
2350
1
731a/02
20 Nov 2011
PART 4: SECTION 9.2 SECURITY GATES Product Name
Type
Width (mm)
Vehicle alley gate incorporating inner pedestrian alley gate Pedestrian alley gate
2150, 2300, 2450, 3010 and 3300 810, 1000, 1100 and 1600 2150, 2300, 2450, 3010 and 3300 2150, 2300, 2450, 3010 and 3300
Vehicle alley gate Vehicle alley gate incorporating inner pedestrian alley gate
Height (mm) 2350
Security Rating 1
Cert. No. 731a/03
2350
21
731a/04
2350
1
2
731a/05
2350
21
731a/06
Compatible locking systems
Model
Type
Wilka 5495
Self locking emergency exit mortice lock
Compatible Cylinders Dom 333i5HT
Approved Product (LPCB Ref. No. 731a/...) 01 02 03 04 05 06
Compatible accessories
Model
Type 01 2
Roller top
Anti-scaling attachment for top of gate
Approved Product (LPCB Ref. No. 731a/...) 02 03 04 05
06
Notes 1. 2. 3. 4.
The deadlock must be fully thrown by turning the key twice in order for the gate to meet Security Rating 2. If the key is only thrown once the gate achieves Security Rating 1. The roller top option can be fitted without undermining the attack resistance provided by the gates. However, the roller top’s resistance to removal is not covered by this approval nor is its resistance to scaling. The gap between the gate and the adjacent walls must not exceed 45 mm. The gap between the bottom of the gate leaf and the ground must be within the following range: (i) 10 mm to 110 mm - AlleygatorTM pedestrian alley gates. (ii) 50 mm to 150 mm - AlleygatorTM vehicle alley gates and vehicle alley gates incorporating pedestrian gates.
20 Nov 2011
491
PART 4: SECTION 9.3 TURNSTILES
Frontier-Pitts Limited Crompton House, Crompton Way, Manor Royal Industrial Estate, Crawley, West Sussex RH10 9QZ, United Kingdom Tel: +44 (0)1293 548301 • Fax: +44 (0)1293 560650 E-mail: [email protected] • Website: www.frontierpitts.com Certificate No: 1059a to LPS 1175: Issue 6
Full Height Turnstile Product Name
Type
Number of Rota Arms
Walkway Width (m)1
Nominal Overall Unit Width 2 1.380
Nominal Overall Unit Depth 2 1.390
Security Rating3, 4, 5
Cert. No.
0.5
Nominal Overall Unit Height (m)2 2.387
Terra Diamond Grade 3 Terra Diamond Grade 4
Single full height turnstile Single full height turnstile
Four
3
1059a/01
Four
0.5
2.387
1.380
1.390
4
1059a/02
Notes: 1. This is measured at the outside entrance to the turnstile. 2. These dimensions are of the entire unit. They include the enclosure above the rotor that contains the drive and control mechanism, but exclude those of the foundations. 3. The turnstiles achieve these security ratings when installed and maintained in accordance with the instructions contained in the Terra Diamond Turnstile Operating and Maintenance Manual (document reference 6614-O&M Issue 4 dated 7 April 2011) and ‘Diamond Turnstile Installation Procedure (document reference 6614-IP Issue 2 dated 9 March 2011), placed in the ‘power to release’ (normal automatic) mode and operated from the ‘attack’ side using an access control system6 having at least 30,000 effective differs that offers compatible resistance to manual attack. 4. The turnstiles offer resistance to attack commensurate with at least Security Rating 1 when placed in the ‘manual release’ mode. 5. The security ratings noted indicate the turnstile’s resistance to forced entry from the outside when mounted within barriers that offer compatible resistance to forced entry in accordance with LPS 1175: Issue 6. 6. The resistance of the access control system, used to operate the turnstiles, to ‘non-mechanical’ attack is not covered as it is outside the scope of LPS 1175: Issue 6. Likewise, the approval does not cover possible effects of any susceptibilities relating to the functionality and performance of any access control equipment that may be used to operate the turnstiles. This is because the scope of access control devices and system configurations that may be used with these locking systems is “infinite”. It is therefore recommended that specifiers satisfy themselves that the components used are either resistant to mechanical and other forms of tampering/abuse, or that they are suitably protected from such tampering/abuse and are resistant to any environmental conditions/interference that may cause the locking system to disengage.
492
20 Nov 2011
PART 4: SECTION 10 VEHICLE SECURITY BARRIER
This section will include vehicle security barriers such as: Fixed bollards Rising bollards Road blockers Drop arm barriers Vehicle security barriers and their associated foundations will be evaluated against the requirements of PAS 68: 2010 Impact test specifications for vehicle security barriers, a standard drawing on the draft LPS 1246 Requirements and test methods for classifying security bollards originally developed by LPCB. Barriers are classified according to the following measurements after a single impact by a vehicle of a defined mass, velocity and angle of impact: The distance the vehicle passed beyond the plane of the barrier. The distance the major debris dispersed beyond the plane of the barrier. It is also intended that, where requested by the manufacturer, the barriers’ resistance to manual attacks aimed at compromising their resistance to vehicle attack will be rated in accordance with LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. LPCB is also working closely with the Perimeter Security Suppliers Association (PSSA) and leading independent laboratories, such as TRL, to develop criteria evaluating and approving other aspects of the barriers performance and durability. This will enable specifiers to select vehicle barriers suitable to the risks identified during a risk assessment of the facilities to be protected.
20 Nov 2011
493
PART 4: SECTION 11 GAS CYLINDER SECURITY DEVICES
This section lists gas cylinder security devices that have been approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. The approval covers the resistance to unauthorised removal of gas cylinders provided by the security devices when installed and maintained in accordance with the approved instructions. While previous versions of the standard specified six levels of resistance (security ratings), the latest version (Issue 6) specifies eight security ratings. These range from opportunist (1 minute attacks using easily concealable hand tools) up to extreme methods of attacks (20 minute attacks using a wide range of hand tools, power tools and thermal cutting equipment). Further details of the grading system can be found in the standard itself, copies of which are available free of charge and can be downloaded from www.RedBookLive.com. The approval does not cover the resistance to unauthorised operation of the gas cylinders when secured by the devices listed. Product Selection When selecting a gas cylinder security device, check that the product’s approval covers the types and sizes of cylinders to be secured, the compatible locking systems listed and the substrates to which the devices may be fixed in order to provide secure anchorage - all can affect the level of security provided by the product. To enable selection of the most appropriate product for the desired application, the listing defines the gas cylinders that are covered by the scope of approval in terms of the supplier, supplier reference and following dimensions:
Key: ha = Height of cylinder, including foot ring and neck ring and/or valve cap hb = Height of cylinder to base of neck ring hc = Height of cylinder to edge of shoulder hd = Height of foot ring da = Diameter at base of neck ring/valve cap db = Diameter of cylinder To achieve the security ratings: (a) the gas cylinder security devices must be installed in accordance with the manufacturer’s instructions;
494
20 Nov 2011
PART 4: SECTION 11 GAS CYLINDER SECURITY DEVICES (b) all locks must be fully engaged and deadlocked; and (c) all exposed fixings, the substrate onto which each device is fitted and the locking mechanism(s) must be regularly checked to ensure they are in good condition and that they have not been tampered with.
Liddle Doors Limited Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698 E-mail: [email protected] • Website: www.liddledoors.co.uk Certificate No: 442c to LPS 1175: Issue 6
Gas Cylinder Security Devices Product Name
Model
Type
Liddle Series 2 Bottle Storage Frame
LD Type A (CL2) LD Type A (SO2) LD Type A (NH3) LD Type B (CL2) LD Type B (SO2) LD Type B (NH3) LD Type C (CL2) LD Type C (SO2) LD Type C (NH3) LD Type D (CL2) LD Type D (SO2) LD Type F (CL2) LD Type F (SO2) LD Type F (NH3)
Three bottle storage frame Three bottle storage frame Three bottle storage frame Two bottle storage frame Two bottle storage frame Two bottle storage frame Four bottle storage frame Four bottle storage frame Four bottle storage frame Six bottle storage frame Six bottle storage frame Single bottle storage frame Single bottle storage frame Single bottle storage frame
Compatible Gas Cylinders 1, 4, 5 and 6
Security Rating 2
2
2
3
2
1, 4, 5 and 6
2
2
2
3
2
1, 4, 5 and 6
2
2
2
3
2
1
2
2
2
1, 4, 5 and 6
2
2
2
3
2
Cert. No. 442c/01
Compatible Locking Systems
Model Abloy PL340 Abloy PL340 Abloy PL340 Abloy PL340 Abloy PL342 Abloy PL342 Abloy PL342 Abloy PL342
Type Padlock Padlock Padlock Padlock Padlock Padlock Padlock Padlock
Cylinder Abloy High Profile Abloy Disklock Pro Abloy Exec Abloy Protec Abloy High Profile Abloy Disklock Pro Abloy Exec Abloy Protec
Compatible Gas Cylinders
20 Nov 2011
495
PART 4: SECTION 11 GAS CYLINDER SECURITY DEVICES Cylinder Reference 1 2 3 4 5 6
Supplier
Height3 (mm)
Model Reference
BOC BOC BOC BOC Ineos Ineos
ha 1120 910 1265 1060 1130 1050
BKA BD BE E3 71kg 33kg
hb 1000 780 1120 940 1020 940
Diameter3 (mm)
hc 930 700 1035 890 950 840
hd 65 60 85 45 65 n/a
da 75 140 90 75 85 85
db 300 320 380 220 290 220
Notes 1. 2.
The 'Liddle Series 2 Bottle Storage Frames' are approved when installed directly onto a flat solid concrete floor. The security rating afforded to the 'Liddle Series 2 Bottle Storage Frames' is based upon every bay within the frame containing a cylinder of the relevant type and dimensions specified. For a key to the cylinder dimensions refer to the introduction of the gas cylinder security device section of the Red Book (RedBookLive.com).
3.
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Certificate No: 450e to LPS 1175: Issue 6
Gas Cylinder Security Devices Product Name Ultrasecure Cylinder Clamp
Type Single cylinder clamp
Gas Cylinders 1, 2, 3, 4 and 5
Security Rating 2
Cert. No. 450e/01
Compatible Locking Systems
Model
Type
Cylinder
Abloy PL340 Abloy PL340 Kaba K20SS65L Kaba Thorlock
Padlock Padlock Padlock Integral lock
Abloy Disklock Pro Abloy Protec Kaba 20 (Armoured) Kaba 20 (Armoured)
Compatible Gas Cylinders
Cylinder Reference
Supplier
Model Reference
1 2 3 4 5
IneosChlor IneosChlor BOC BOC BOC
71 kg 33 kg BKA E3 BD
Height (mm) ha 1130 1050 1120 1060 910
hb 1020 940 1000 940 780
hc 950 840 930 890 700
hd 65 n/a 65 45 60
Diameter (mm) da db 85 290 85 220 75 300 75 220 140 320
Note 1.
496
The device is approved when installed in accordance with document CCU-DV-FIT-01 (Issue 2).
20 Nov 2011
PART 4: SECTION 12 PHYSICAL SECURITY DEVICES FOR COMPUTERS AND OTHER ICT EQUIPMENT
At the request of the Association of British Insurers, the LPCB developed LPS 1214 Specification for testing and classifying physical protection devices for personal computers and similar equipment for the performance of security equipment designed to prevent removal of computer and other office equipment: The standard currently defines two categories of protection. Both categories of device prevent theft of the complete computer for three minutes allowing a response by Police or security guards, while Category II products also prevent removal of the computer chips for the same period. Suitable applications for products certified to LPS 1214 are described below: Category I:
Prevent unauthorised removal of personal computers (PCs), file servers, printers, facsimile machines and other high value equipment for example where access is important for use and the component value is low.
Category II:
Prevent unauthorised removal of or access to personal computers (PCs), file servers, printers, facsimile machines and other high value equipment for example where the PC is both important and highly valued and/or the component value is high.
Specifiers requiring category II devices should ensure that they select a device suitable for their particular equipment and that there is suitable ventilation of the computer in accordance with any instructions and warranty conditions supplied with the computer. In order that they will provide the required protection, the approved equipment must be installed in accordance with the manufacturer’s instructions and be in the locked condition with keys removed and held in a secure location. It is recommended that users regularly check that all exposed fixings and locking mechanisms are in good condition and that they have not been tampered with. In addition to approving physical protection devices for personal computers and similar equipment to LPS 1214, LPCB also evaluate and approve the following equipment designed to secure larger volumes of ICT equipment to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers: - Racking systems - Modular enclosures - Composite panelling systems designed for constructing data halls. Security products approved to LPS 1175 Security Rating 2 provide an equivalent resistance to forced entry as that provided by an LPS 1214 Category I device. It should be noted that the resistance provided by each enclosure approved to LPS 1214 category I or LPS 1175 Security Rating 2 used to secure individual items of ICT equipment matches the resistance provided by products, such as doors and partitioning systems, rated to Security Rating 2 in LPS 1175 that secure larger quantities of ICT equipment. It is therefore recommended that specifiers individually secure items of ICT equipment especially when located in multi-user spaces, such as schools and offices, and open access areas such as libraries. It is also recommended that all equipment is marked with an asset management marking system approved to LPS 1225 and registered on a secure asset database certified to LPS 1224. Marking devices and secured database services are listed in Sections 13 and 14 of Part 4. Products that have been certified by LPCB should be marked with a label indicating the level of security offered, LPCB certification mark and certificate number.
20 Nov 2011
497
PART 4: SECTION 12 PHYSICAL SECURITY DEVICES FOR COMPUTERS AND OTHER ICT EQUIPMENT
Bradbury Security Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888 E-mail: [email protected] • Website: www.bradburyuk.com Certificate No: 312b to LPS 1214: Issue 2
Server Security Cabinets Product Name Ventis Server Safe Sun Safe System Vault
Type
Model -
Height (mm) 2127
Width (mm) 725
Depth (mm) 1100
Security Category II
Server enclosure with single door in front and rear Server enclosure with single door in front and rear Server enclosure with single door in front and rear Server enclosure with single door in front and rear Server enclosure with single door in front and rear Server enclosure with single door in front and rear Server enclosure with single door in front and rear Server enclosure with single door in front and rear Server enclosure with double door in front and rear Server enclosure with double door in front and rear Server enclosure with double door in front and rear Server enclosure with double door in front and rear Server enclosure with double door in front and rear
UKT-SUNSAFE-1
2160
725
1500
II
UKT-SUNSAFE-2
2160
725
1265
II
UKT-SUNSAFE-3
2160
725
1100
II
UKT-SUNSAFE-6
1000
725
1000
II
UKT-SUNSAFE-7
1000
725
900
II
Made to measure: min. size Made to measure: max. size UKT-SUNSAFE-4
1000
600
600
II
2500
1000
2000
II
2160
1000
1500
II
UKT-SUNSAFE-5
2160
1000
1853
II
UKT-SUNSAFE-8
2160
1000
1265
II
Made to measure: min. size
1000
700
600
II
Made to measure: max. size
2500
2000
2000
II
Cert. No. 312b/03
Compatible Locks
Lock Dom Nemef DDLK
Type Mortice Lock
Cylinder Mul-T-Lock Interactive single Euro-profile cylinder or Santos 725 single Euro-profile cylinder
Notes 1. 2.
The above approval applies to these products when assembled and installed strictly in accordance with the instructions provided with the product. In order to offer the required level of security, all locks must be engaged and the keys removed.
Dalen Limited Valepits Road, Garretts Green Industrial Estate, Birmingham B33 0TD, United Kingdom Tel: +44 (0)121 783 3838 • Fax: +44 (0)121 784 6348 E-mail: [email protected] • Website: www.top-tec.co.uk Certificate No: 276a to LPS 1214: Issue 2
498
20 Nov 2011
PART 4: SECTION 12 PHYSICAL SECURITY DEVICES FOR COMPUTERS AND OTHER ICT EQUIPMENT Computer Security Devices Product Name
Type
T-T450/1
Adjustable tower computer security cage Adjustable tower computer security cage Adjustable tower computer security cage Front opening bespoke range of security entrapments for tower computers Front opening bespoke range of security entrapments for tower computers Modular laptop security enclosures3
T-T450/2
T-T460/2
T-T418 (4)
T-T419
T-T540 Nightsafe
Maximum Computer Height (mm) 380
Maximum Computer Width (mm) 190
Maximum Computer Depth (mm) -
Minimum Computer Height (mm) 330
Minimum Computer Width (mm) 165
Minimum Computer Depth (mm) 440
Security Category
Cert. No.
I
276a/01
430
190
-
380
165
440
I
276a/02
180
515
700
100
300
355
I
276a/03
700
400
700
250
180
300
I
276a/04
300
800
700
110
200
350
I
276a/05
500
250
500
330
95
330
II
276a/06
Notes 1. 2. 3. 4.
The approval applies to these products when installed strictly in accordance with the instructions provided with the product. The substrate and fixings for wall and floor mounting may affect the performance of the product and are therefore outside the scope of the approval. The Nightsafe units are modular units available with between three and nine compartments each designed to take computers within the size range specified above. The T-T418 may also be sold under the alternative model reference T-T SE 0250.
Certificate No: 276b to LPS 1214: Issue 2
Projector Security Devices Product Name
T-T140/3 Projector cage T-T140/4 Projector cage
Cage Dimensions Depth (mm) 386
Cage Dimensions Width (mm) 319
Cage Dimensions Height (mm) 115
Pole Length Minimum (mm) 500
Pole Length Maximum (mm) 1500
Security Category
Cert. No.
I
276b/01
386
319
140
500
1500
I
276b/02
Suitable for use with the projectors within the following size range:
Product Name
T-T140/3 Projector cage
Depth (mm) 150
Minimum Width (mm) 150
Height (mm) 50
T-T140/4 Projector cage
150
150
50
Depth (mm) 225
Maximum Width (mm) 340
Height (mm) 95
225
340
115
Compatible locks
20 Nov 2011
499
PART 4: SECTION 12 PHYSICAL SECURITY DEVICES FOR COMPUTERS AND OTHER ICT EQUIPMENT
Lock Designation Lowe and Fletcher 10 pin radial tumbler lock Manseng Enterprise Co. Ltd, 7 pin radial push button lock
T-T140 (LPCB Ref. No. 276b/...) 01 02
Note 1.
500
The approval only applies to the projector cages when used in conjunction with the T-T105 pole and T-T105-CU ceiling unit, and installed strictly in accordance with the following instructions: T-T140 iss5.pub CC_INST T-T 105-CU iss3.pub CC_INST T-T 105-Pole iss1.pub
20 Nov 2011
PART 4: SECTION 13 DATABASE MANAGEMENT FOR ASSET MARKING
The essential requirements of LPS 1224:Issue 2 Requirements for Secure Database Registers were developed as a result of needs identified by the Police, Insurers and Home Office. LPS 1224 ensured that Police and other legitimate enquirers can confirm ownership of property 24 hours a day while ensuring full details of property ownership are held securely and in accordance with the Data Protection Act. Therefore, under the requirements of LPS 1224, the database operator must: (i) Have an established track record in the field of asset registration of at least one year. (ii) Operate the database in accordance with a documented set of procedures in accordance with the requirements defined in LPS 1224. (iii) Offer a telephone check line service manned by trained operatives. In accordance with Government policy, the service shall be available 24 hour a day access and shall be free of direct charge to the enquirer, e.g. it shall not chargeable to the enquirer as a premium rate telephone service. This section lists companies that run databases that have been assessed and approved to LPS 1224. More recently LPS 1224:Issue 3 Requirements for companies providing security asset registration services was developed. This covers database services provided over the internet as well as those which may be accessed using other media.
Datatag ID Limited 3000 Hillswood Drive, Hillswood Business Park, Chertsey, Surrey KT16 0RS, United Kingdom Tel: +44 (0)1932 895304 • Fax: +44 (0)1932 796797 E-mail: [email protected] • Website: www.datatag.co.uk 24/7 Telephone Number: 0845 0700 440
Certificate No: 665a to LPS 1224: Issue 2
Secure Database Register Product Name Datatag ID Secure Database
Telephone Number 08450 700440
Web Address as above
Cert. No. 665a/01
Retainagroup Limited Unit 5, St John's Court, Foster Road, Ashford Business Park, Ashford, Kent TN24 0SJ, United Kingdom Tel: +44 (0)1233 506400 • Fax: +44 (0)1233 506401 E-mail: [email protected] • Website: www.retainagroup.com Certificate 493a 5 Windward House, Plantation Wharf, London SW11 3TU, United Kingdom Tel: 24 hour 07000 111333
Certificate No: 493a to LPS 1224: Issue 2
Secure Database Register Product Name International Security Register
20 Nov 2011
Telephone Number 07000 111333
Web Address As above
Cert. No. 493a/01
501
PART 4: SECTION 13 DATABASE MANAGEMENT FOR ASSET MARKING
Selectamark Security Systems plc 1 Locks Court, 429 Crofton Road, Locksbottom, Kent BR6 8NL, United Kingdom Tel: +44 (0)1689 860757 • Fax: +44 (0)1689 860693 E-mail: [email protected] • Website: www.selectadna.co.uk Certificate No: 497b to LPS 1224: Issue 3
Secure Database Register Product Name Selectamark Secure Asset Register
Telephone Number +44 (0)1689 860757
Hours of Operation1
Web Address
9 am to 5 pm on weekdays, excluding bank holidays
www. secureassetregister.com
Postal Address 1 Locks Court, 429 Crofton Road, Locksbottom Kent BR6 8NL
Security Level 2
Cert. No. 497b/01
Note: 1. These are the hours during which the telephone helpline is available. These are based on UK time.
502
20 Nov 2011
PART 4: SECTION 14 ASSET MARKING SYSTEMS
The following marking devices listed have been tested to LPS 1225 Specification for testing and classifying asset marking systems. LPS 1225 specifies requirements for the composition and performance of an asset marking system such that, when used according to the manufacturer’s instructions, the asset marking device may: i)
Enable the marked asset to be traced to the legal owner via a secure database register linked to the marking system employed.
ii)
Act as a theft deterrent in the first instance by virtue of known existence.
It is assumed that the part of the asset to which the asset marking device is applied is at least equal in resistance to removal from the asset as the asset marking device employed. The two-part classification indicates the resistance of the product to eradication of ownership traceability and resistance to complete removal of marking without leaving evidence of previous existence. This gives the enduser the option of selecting a product to suit the required application. Complete removal of the marking and restoration of the asset gives maximum resale value to the stolen asset; however the standard does not take into account replication or replacement of components as part of asset restoration. The overall classification designation achieved is given by two numerals separated by a plus sign. The first numeral represents the resistance rating to erasure of traceability and the second numeral to complete removal/asset restoration. The two classifications are both on a scale of one to eight. Classification ‘1’ performance relates to that which should be expected as a minimum for marking devices used in the retail trade and other public areas equipped with CCTV and security staff. Classification ‘8’, on the other hand, is aimed at marking devices applied to assets that have a high value and this will be the subject of a more determined level of effort by the criminal in order to prevent traceability or completely remove the mark. Long term durability of the system and associated components are beyond the scope of this standard, as are the performance requirements of any covert marking technology incorporated in the system. Although this standard specifies that the product instructions shall include hazard data, confirmation of the authenticity of such data is not addressed. All approved marking devices are marked with a unique asset identification code. The LPCB certification mark and reference numbers relating to the marking device and database, and the telephone number of the database will also be marked on the marking device, or where this is not viable, on separate warning labels which are supplied with the marking device. In addition to LPS 1225, LPCB is currently working with manufacturers and specifiers to finalise standards classifying the performance of “microdot”, “trace chemical” and RFID marking systems. Please contact LPCB for further details.
20 Nov 2011
503
PART 4: SECTION 14 ASSET MARKING SYSTEMS
Retainagroup Limited Unit 5, St John's Court, Foster Road, Ashford Business Park, Ashford, Kent TN24 0SJ, United Kingdom Tel: +44 (0)1233 506400 • Fax: +44 (0)1233 506401 E-mail: [email protected] • Website: www.retainagroup.com Certificate 493b 5 Windward House, Plantation Wharf, London SW11 3TU, United Kingdom Tel: 24 hour 07000 111333
Certificate No: 493b to LPS 1225: Issue 3
Overt Asset Marking Systems Product Name
Substrate
The Retainagroup Marking and Registration System for Vehicles Marking and Registration System for Vehicles
Float glass Laminated glass Toughened glass ABS Plastic
The Retainagroup Marking and Registration System for Office and Household Equipment
Resistance Rating Classification 2+8 2+8
Database Ref. No.
Cert. No.
493a/01 493a/01
493b/01
2+8
493a/01
1+2
493a/01
493b/02
Note 1.
Effective marking of materials, in particular plastics, is dependent upon the specific material type, material constituents and surface finish. If you are in any doubt over the likely performance of these marking devices in your situation please contact the manufacturer.
Selectamark Security Systems plc 1 Locks Court, 429 Crofton Road, Locksbottom, Kent BR6 8NL, United Kingdom Tel: +44 (0)1689 860757 • Fax: +44 (0)1689 860693 E-mail: [email protected] • Website: www.selectadna.co.uk Certificate No: 497a to LPS 1225: Issue 3
Overt Asset Marking Systems Product Name Selectamark (7mm)
Type of Marking Device Glass etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'UV-Orange' etching compound 'UV-Orange' etching compound 'UV-Orange' etching compound 'UV-Orange' etching compound 'UV-Orange' etching compound 'UV-Orange' etching compound 'UV-Orange' etching compound
504
Substrate Float glass ABS plastic Enamel finished steel Leather Polycarbonate Polymethyl Methacrylate ("Perspex") Planed softwood timber Planed hardwood timber Plywood PVC ABS plastic Enamel finished steel Leather Polycarbonate Polymethyl Methacrylate ("Perspex") Planed softwood timber Planed hardwood timber
Resistance Rating Classification 1+8
Database Ref. No.
Cert. No.
379a
497a/01
1+2 1+1 1+2 2+5 1+3
379a 379a 379a 379a 379a
497a/02
1+1 1+1 1+1 1+2 1+2 1+1 1+2 2+5 1+3
379a 379a 379a 379a 379a 379a 379a 379a 379a
1+1 1+1
379a 379a
497a/03
20 Nov 2011
PART 4: SECTION 14 ASSET MARKING SYSTEMS Product Name
Supermark (5mm)
Type of Marking Device 'UV-Orange' etching compound 'UV-Orange' etching compound Label and 'Blue' etching compound Label and 'Blue' etching compound Label and 'Blue' etching compound Label and 'Blue' etching compound Label and 'Blue' etching compound
Selectamark (5mm)
Label and 'Blue' etching compound Label and 'Blue' etching compound Label and 'Blue' etching compound Label and 'Blue' etching compound Label and 'UV-Orange' etching compound Label and 'UV-Orange' etching compound Label and 'UV-Orange' etching compound Label and 'UV-Orange' etching compound Label and 'UV-Orange' etching compound Label and 'UV-Orange' etching compound Label and 'UV-Orange' etching compound Label and 'UV-Orange' etching compound Label and 'UV-Orange' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Blue' etching compound 'Ice Blue' etching compound 'Ice Blue' etching compound 'Ice Blue' etching compound 'Ice Blue' etching compound
Selectamark (7mm)
'Ice Blue' etching compound 'Ice Blue' etching compound 'Ice Blue' etching compound 'Ice Blue' etching compound 'Ice Blue' etching compound
Supermark (5mm)
'Ice Blue' etching compound Label and 'Ice Blue' etching compound Label and 'Ice Blue' etching compound Label and 'Ice Blue' etching compound Label and 'Ice Blue' etching compound Label and 'Ice Blue' etching compound Label and 'Ice Blue' etching compound
Substrate
Resistance Rating Classification 1+1 1+2 1+3
Database Ref. No.
Cert. No.
379a 379a 379a
497a/04
Enamel finish steel Polycarbonate Polypropylene Polymethyl Methacrylate ("Perspex") Planed softwood timber Planed hardwood timber Plywood PVC ABS plastic
1+2 1+4 1+2 1+4
379a 379a 379a 379a
1+2 1+2 1+2 1+3 1+3
379a 379a 379a 379a 379a
Enamel finished steel
1+2
379a
Polycarbonate
1+4
379a
Polypropylene
1+2
379a
Polymethyl Methacrylate ("Perspex") Planned softwood timber
1+4
379a
1+2
379a
Planed hardwood timber
1+2
379a
Plywood
1+2
379a
PVC
1+3
379a
ABS plastic
1+2
379a
Enamel finished steel Polycarbonate Polymethyl Methacrylate ("Perspex") PVC ABS plastic Enamel finished steel Polycarbonate Polymethyl Methacrylate ("Perspex") PVC ABS plastic
1+1 2+5 1+3
379a 379a 379a
1+2 1+2 1+1 2+5 1+3
379a 379a 379a 379a 379a
1+2 1+2
379a 379a
Enamel finished steel Polycarbonate Polymethyl Methacrylate ("Perspex") PVC ABS plastic
1+2 2+5 1+3
379a 379a 379a
1+2 1+3
379a 379a
Enamel finished steel
1+2
379a
Polycarbonate
1+4
379a
Polymethyl Methacrylate ("Perspex") Polypropylene
1+4
379a
1+2
379a
PVC
1+3
379a
Plywood PVC ABS plastic
497a/05
497a/02
497a/07
497a/06
Note 1.
Effective marking of materials, in particular plastics, is dependent upon the specific material type, material constituents surface colour and finish. If you are in any doubt over the likely performance of these marking devices in your situation please contact the manufacturer.
20 Nov 2011
505
PART 4: SECTION 15 'THEFT RESISTANT' ELECTRONIC PRODUCTS
This section lists ‘theft resistant’ electronic products that have been assessed to LPS 1650 Requirements and testing procedures for the LPCB approval and listing of ‘theft resistant’ electronic products. This includes:
In-car entertainment systems DVD players and writers Health care equipment Laptops Mobile telephones MP3 players
PDA’s Personal computers Projectors and wipe boards Printers Satellite navigation devices Televisions and screens
The attributes that make these products particularly desirable to thieves can be summarised into six elements and these elements are often referred to by the acronym CRAVED. Concealable, Removable, Available, Valuable, Enjoyable and Disposable. Whilst each element can be used to determine which products are likely to be stolen, the frequency at which the thefts occur may ultimately depend on just one attribute, the ease at which the item can be disposed. The intention of LPS 1650 is to encourage the use of effective security features that make it difficult to return the product to a ‘re-saleable’ condition if stolen, thus reducing the level to which they are craved by criminals. Whilst the standard does not specify any one particular design of anti-theft technology it includes requirements for the performance of the following types: Denial of service technologies, such as PIN codes, removal coded panels and electronic keys
– Use of effective denial of service technology can prevent the product being enjoyed by persons other than the legitimate owner(s). Asset marking systems (overt and covert) linked to secure – Asset marking that cannot be removed without damaging the databases providing traceability to the legal owner of the product can make it harder for the thief to dispose of the item product and reduce the value of the goods if removal is attempted. Anchoring devices providing mechanical resistance against – Secure fixing to a solid mounting surface can increase the unauthorised removal of the product effort required to remove the product. Alarm /signalling technologies providing warning of attempted – An audible alarm could make the product less concealable. removal
The requirements and tests of LPS 1650 permit the assessment and rating of the performance of the anti-theft security features built into or supplied with the product. Where appropriate reference is made to specific requirements of standards such as LPS 1224 Requirements for secure database registers, LPS 1225 Requirements for the LPCB approval and listing of asset marking systems, LPS 1214 Specification for testing and classifying physical protection devices for personal computers and similar equipment and a number of other applicable European standards. The overall security performance rating is indicated by a series of security performance classifications. To meet the minimum requirement of LPS 1650 products must achieve at least one denial of service classification. The security performance rating is expressed in the following format:
506
20 Nov 2011
PART 4: SECTION 15 'THEFT RESISTANT' ELECTRONIC PRODUCTS
For details of the security performance rating parameters and their classification refer to LPS 1650.
20 Nov 2011
507
PART 4: SECTION 16 LETTER PLATES AND LETTER BOXES (MAIL BOXES)
Letter plates and letter boxes (otherwise known as mail boxes) listed within this section have been evaluated in accordance with either LPS 1175 Specification for testing and classifying the burglary resistance of building components, strongpoints and security enclosures or BS EN 13724: 2002 Postal services - Apertures of private letter boxes and letter plates - Requirements and test methods. LPS 1175 currently specifies eight grades of security according to the severity of the likely attack ranging from opportunists (security rating 1) through to professional criminals. The ratings are determined in terms of attack tools and time available to the attacker, and enables specifiers to select products according to the risks that they and their property face. The failure criteria used will suit the intended application of the products listed. These may include boxes designed to prevent the unauthorised removal of the contents of a letter box to letter plates and boxes with lockable flaps that are designed to prevent deliveries being made during periods when the properties to which they are fitted are left empty. Details regarding the classification system used when rating products to LPS 1175 can be found within the standard itself, copies of which are available free of charge and can be downloaded from the LPCB web site www.RedBookLive.com. BS EN 13724: 2002 classifies apertures of letter boxes and plates according to the following: Type of aperture Size of aperture Corrosion resistance and water penetration Security. The classification is determined by taking a series of measurements and conducting a series of mechanical tests including soak tests (water), salt spray tests to EN 1670 (corrosion) and load tests (security). The security requirements contained within BS EN 13724: 2002 are considered to be less severe than those of the minimum security rating defined in LPS 1175, i.e. Security Rating 1. It is important to ensure that the letter plates and boxes are installed in accordance with the manufacturers instructions and that all exposed fixings, the substrate to which the product is fitted, and any locking mechanisms incorporated within the product are regularly checked to ensure that they are in good condition and that they have not been tampered with.
The Safety Letter Box Company Limited Unit 1B, Milland Industrial Estate, Milland Road, Neath, West Glamorgan SA11 1NJ, United Kingdom Tel: +44 (0)1639 633525 • Fax: +44 (0)1639 646359 E-mail: [email protected] • Website: www.safetyletterbox.com Certificate No: 962a to LPS 1175: Issue 6
Security Letter plate Product Name Flaplock FL05
Type
Scope of Installation
Internal letter plate
Mounting on the rear of 44 mm thick solid timber door leaves over letter slots measuring 45 mm by 250 mm
Security Rating 1
Cert. No. 962a/01
Function
508
20 Nov 2011
PART 4: SECTION 16 LETTER PLATES AND LETTER BOXES (MAIL BOXES) The ‘Flaplock5’ helps to prevent the following when installed in accordance with the instructions contained on the document ‘FL05 FIT INST Rev 1’ and the flap is secured by inserting the pegs provided into the yolks located at both ends of the flap: -
Insertion of litter, mail and other unwanted items into the property via the letter plate aperture. Removal of keys and other items from within the property via the letter plate aperture1. Access to locking hardware fitted to the door via the letter plate aperture by those attempting to gain unauthorised entry into the property by operating such hardware.
Note 1.
It is recommended that such items are not stored within the immediate proximity of the letter plate.
20 Nov 2011
509
PART 4: SECTION 17 KEY SAFES
Key safes listed in this section are approved to LPS 1175 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongholds, security enclosures and freestanding barriers. Unless otherwise stated, the security rating attributed to each key safe listed in this section relates to the key safes’ resistance to the following methods of attack: Forced entry into the key safe to remove a key stored within it. Unauthorised removal of the key safe from the supporting substrate. It is recommended that the security ratings of the key safes used to store keys are at least equivalent to those of the products (e.g. doorsets) the keys operate. This is particularly important if the key safes are located in unprotected areas, for example, on the outside of properties. This is to ensure the key safes do not compromise the resistance to forced entry provided by the products that the keys operate.
UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH, Weert, The Netherlands Tel: +31 495 583000 • Fax: +31 495 550042 E-mail: [email protected] Europe, Middle East, Africa sales: UTC Fire & Security, Supra Asset Protection Solutions, Kouterveldstraat 2, B-1831 Diegem, Belgium Tel: +32 478 98 32 81 E-mail: [email protected]
UK sales: Supra UK Ltd, 24 The Furlong, Berry Hill Industrial Estate, Droitwich Spa, Worcestershire WR9 9AH, United Kingdom Tel: +44 (0)1905 770333 E-mail: [email protected]
Certificate No: 1062a to LPS 1175: Issue 6
Key Safes Product Name
Model
Supra P500
Wall mounted key safe with twelve button combination Wall mounted key safe with twelve button combination Wall mounted key safe with twelve button combination incorporating an alarm switch Wall mounted key safe with twelve button combination incorporating an alarm switch
Supra Consumer 500 Supra P500 with alarm switch Supra Consumer 500 with alarm switch
Part No. 002045 002049 002046 002050
Instructions P/N10102761P1 December 2009 P/N10102770P1 December 2009 P/N10102761P1 December 2009 P/N10102770P1 December 2009
Security Rating 1
Cert. No. 976a/01
1
976a/02
1
976a/03
1
976a/04
Notes: 1. The Supra key safes are approved when mounted directly to masonry walls in accordance with the instructions noted in the above table. The approval does not cover the key safes when mounted to alternative substrates or via intermediate substrates such as plasterboard.
510
20 Nov 2011
PART 4: SECTION 18 SECURITY GLAZING
This section includes security glazing that has been approved to one or more of the following standards: LPS 1270: Issue 1 Requirements and testing procedures for the LPCB approval and listing of intruder resistant security glazing units BS EN 356: 2000 Glass in Building - Security Glazing - Testing and classification of resistance against manual attack BS EN 1063: 2000 Glass in building. Security glazing. Testing and classification of resistance against bullet attack. LPS 1270 was developed because it was considered the method for classifying the attack resistance of security glazing specified within the current European standard (BS EN 356: 2000) was incompatible with that employed within LPS 1175: Issue 7 Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. This was because: BS EN 356: 2000 does not classify glass according to its resistance to different levels of attack based on the tools and time available to an intruder. The tests contained within BS EN 356: 2000 do not evaluate the glass’s susceptibility to attacks involving the creation of small holes through which locking hardware may be manipulated and/or protected items, such as items on display within shop windows or display cases, may be removed. Glazing materials rated to BS EN 356: 2000 that have previously been included within products and systems submitted for testing to LPS 1175: Issue 7 has undermined those product’s/system’s ability to offer intruder resistance commensurate with the security ratings sought to LPS 1175: Issue 7. The LPS 1270 classification system contains three digits. Each digit describes the glazing’s resistance to creation of a different size of hole, as described in the table below. Digit 1
Type Tests block Local 8 mm (+3 mm/-0 mm) by penetration 25 mm (+3 mm/-0 mm) rectangular section
2
Hand hole
3
Complete access
Notes Represents the glazing’s likely resistance to creation of a hole through which a piece of wire, screwdriver, lever or other such device can be passed. Such an attack may be attempted by an intruder wishing to operate a panic bar, emergency lever handle or other non-deadlocked device capable of releasing the boltwork on the item in which the glazing is mounted or on an item directly adjacent to that in which the glazing is mounted. 60 mm (+3 mm/-0 mm) Represents the glazing’s likely resistance to creation of a diameter hand hole. Such an attack may be attempted by an intruder wishing to: • Operate a thumbturn to release the boltwork on the item in which the glazing is mounted or on an item directly adjacent to that in which the glazing is mounted. • Retrieve an item from the protected side of the glass, e.g. an item on display behind a shop window, a set of door keys or a set of car keys. Elliptical section of 400 mm This reflects the size of aperture specified in LPS 1175: (+3 mm/-0 mm) major axis Issue 7. The digit confirms the glazing’s resistance to by 225 mm (+3 mm/-0 mm) creation of a hole through which an elliptical test block measuring 400 mm by 225 mm may be passed. This minor axis replicates the size a person may be able to pass through and reflects the test block defined in LPS 1175: Issue 7.
The glazing’s resistance to creation of each size of hole will be indicated by a number (security rating) 0 to 8. The tools and time that the glazing must resist in order to achieve the security ratings match those that products classified in accordance with LPS 1175: Issue 7 must resist. The only difference is that glazing may
20 Nov 2011
511
PART 4: SECTION 18 SECURITY GLAZING also achieve a ‘0’ rating in the first and second digits. Such a rating indicates the glazing’s resistance to the creation of those sizes of hole falls below that required to achieve security rating 1. The security ratings are loosely based upon domestic risks (security ratings 1 and 2), commercial risks (security ratings 2, 3 and 4), high security risks (security ratings 5 and 6) and extremely high security facilities (security ratings 7 and 8). In order to be classified to LPS 1270, glazing units must achieve a security rating of at least “001”. When selecting security glazing units it is important to consider other aspects of the product (e.g. window, doorset or curtain walling system) into which the glazing unit is to be fitted. In particular, it is important to consider the method by which the glazing unit is held in place. Manufacturers and specifiers should therefore ensure the complete product or system is assessed and classified in accordance with LPS 1175: Issue 7 rather than simply the glazing.
Essex Safety Glass Limited Units 1-3, Moss Road, Witham, Essex CM8 3UG, United Kingdom Tel: +44 (0)1376 520061 • Fax: +44 (0)1376 521176 E-mail: [email protected] • Website: www.esguk.co.uk Certificate No: 997a to LPS 1270: Issue 1
Laminated Security Glazing Product Name
Type
ESG Secure LPS 001/13 ESG Secure LPS 112/17 ESG Secure LPS 123/19 ESG Secure LPS 123/23 ESG Secure LPS 223/31 ESG Secure LPS 224/40 ESG Secure LPS 234/44 ESG Secure LPS 235/57
Laminated single glazing unit1, 2, 3, 4 Laminated single glazing unit1, 2, 4, 5 Laminated single glazing unit1, 2, 4, 5 Laminated single glazing unit1, 2, 4, 5 Laminated single glazing unit1, 2, 3, 4 Laminated single glazing unit1, 2, 3, 4 Laminated single glazing unit1, 2, 4, 5 Laminated single glazing unit1, 2, 3, 4
Nominal Total Thickness (mm) 13
Nominal Weight (kg/m2 26.6
Security Rating 001
Cert. No. 997a/01
17
28.8
112
997a/02
19
31.2
123
997a/03
23
36
123
997a/04
31
50.1
223
997a/05
40
62.2
224
997a/06
44
59.2
234
997a/07
57.5
90
235
997a/08
Notes: 1. The number within the product code indicating the thickness will be greater than that noted if thicker layers are used than those noted for the standard glazing units listed. 2. The 4 mm toughened glass layer on the attack face of the glazing unit may be replaced by 4 mm float glass, 4 mm heat strengthened glass, 4 mm ‘ESG Pyrotech’ glass or 6 mm ‘ESG Pyrotech’ glass. However, these options may affect the nominal thickness and weight noted for this ‘ESG Secure’ glazing unit. 3. The 4 mm float glass layer on the non-attack face of the glazing unit may be replaced by thicker float glass up to 19 mm, toughened glass between 4 mm and 19 mm thick, heat strengthened glass between 4 mm and 19 mm thick, 4 mm ‘ESG Pyrotech’ glass or 6 mm ‘ESG Pyrotech’ glass. However, these options may affect the nominal thickness and weight noted for this ‘ESG Secure’ glazing unit. 4. As an alternative to the single glazing units, Essex Safety Glass Limited also supply double glazed units (DGUs) formed using the glazing units approved to LPS 1270. The DGU’s are formed by adding a layer of float glass, toughened glass, heat strengthened glass or ‘ESG Pyrotech’ glass to the non-attack face. These are separated from the glazing units listed above by a spacer between 6 mm and 22 mm thick. The DGUs are therefore thicker and heavier than the ‘ESG Secure’ single glazing units listed above. The product codes for ‘ESG Secure’ DGUs include the letters DGU immediately before the unit’s total thickness. For example, the ‘001/11’ unit with a 6 mm spacer and 4 mm toughened glass on the non-attack side of the DGU would have a code ‘001/DGU21’. 5. The 4 mm toughened glass layer on the non-attack face of the glazing unit may be replaced by thicker toughened glass up to 19 mm, float glass between 4 mm and 19 mm thick, heat strengthened glass between 4 mm and 19 mm thick, 4 mm ‘ESG Pyrotech’ glass or 6 mm ‘ESG Pyrotech’ glass. However, these options may affect the nominal thickness and weight noted for this ‘ESG Secure’ glazing unit.
512
20 Nov 2011
Part 5 CONSTRUCTION PRODUCTS
PART 5: CONSTRUCTION PRODUCTS INTRODUCTION The products listed in this part of the Red Book have been assessed for ‘Technical Approval’ (or Certification) based on the intended use of the product, and take into account the UK Building Regulations, Highways Regulations, the Essential Requirements from the Construction Products Directive (CPD) and other directives as necessary. Most of the approvals listed are for products and systems for which there are no directly applicable recognised standards and a Technical Approval certification has been granted. Where British, European or other recognised standards apply, we also approve products against these standards. The granting of certification depends on the type testing and initial factory assessments meeting the relevant standards and scheme requirements laid down. Certification is maintained by regular factory production control surveillance visits and, where specified, the testing of audit samples to ensure that the product continues to be made in exactly the same way. IMPORTANT We are currently changing the way that we approve and certificate products with the result that we will not be issuing any new Technical Approvals. In the future, new certificates will issued against published BRE Schemes and, where appropriate BRE Product Standards (BPS). Details of current Schemes and associated BPSs can be found at: www.RedBookLive.com This does not affect the validity of the current Technical Approvals listed in this section. These will remain valid for three years from their date of issue - or until converted into one of our new range of Approved Building Product certificates.
514
20 Nov 2011
PART 5: SECTION 1 ANCHORS, CONNECTORS, FASTENERS AND FIXING SYSTEMS
The scope of products approved under this section is as follows: Anchors, connectors, fasteners and fixing components and systems manufactured from metals and plastics for providing mechanical jointing between components, or to fix to substrates of concrete, masonry, metal, timber and plastics, for building and construction products and kits over a specified design life.
Max Frank Limited Whittle Road, Meir, Stoke-on-Trent, Staffordshire ST3 7HF, United Kingdom Tel: +44 (0)1782 598041 • Fax: +44 (0)1782 315056 E-mail: [email protected] • Website: www.maxfrank.co.uk Certificate No: 136/07 Rev Oct 10 Certificated Products Shearail punching shear reinforcement
20 Nov 2011
Shearail punching shear reinforcement has been assessed to confirm its suitability, within limitations, for use as a punching shear reinforcement in reinforced concrete floor and roof slabs in buildings. The product comprises a set of forged steel studs (smooth or ribbed) connected at one end to a steel rail which is used to position them in the construction prior to placement of structural concrete. The product is available in a range of stud sizes. Studs are welded to the rails at predetermined spacing. Shearails are produced to meet specific project requirements. The minimum number of studs on a rail is two.
Cert. No. 136/07 Rev Oct 10
515
PART 5: SECTION 2 DRAINAGE AND PLUMBING SYSTEMS
The scope of products approved under this section is as follows: Drainage and plumbing products, systems and kits for domestic, commercial and industrial building applications manufactured from clay and cementitious based materials, plastics, metals and composites to provide for transfer and containment of potable and foul water, rainwater, sewage and effluent over a specified design life.
516
20 Nov 2011
PART 5: SECTION 3 FLOORING SYSTEMS
The scope of products approved under this section is as follows: Flooring products, systems and kits for floor bases and floor finishes for domestic, commercial and industrial building applications manufactured from gypsum, clay and cementitious based materials, plastics, timber, metals and composites to provide support for loading, decoration and thermal, acoustic and fire protection over a specified design life.
Intelligent Engineering (UK) Ltd Shire House, West Common, Gerrards Cross, Slough, Bucks SL9 7QN, United Kingdom Tel: +44 (0) 1753 890 575 • Fax: +44 (0) 1753 899 056 E-mail: [email protected] • Website: www.ie-sps.com Certificate No: ABP008 to BPS7007 Certificated Products Flooring System permanent and temporary stadium risers
SPS Terraces are individual step units which are joined together one above the other in sets of four to form terraces. Each step unit consists of a horizontal sandwich panel (4mm steel faceplates with a 20mm high density (≥1000kg/m3) polyurethane core) welded to steel plate risers. Connections between individual step units are made with proprietary fasteners which are also used to fix steel bracing and closing plates to completed terraces.
Cert. No. ABP008
SPS Terraces are available with a horizontal step width of 830mm and riser heights of 178mm (7”) and 365mm (14”). Terraces consisting of four step units having a maximum length of 10m are supported on a braced steel perimeter frame. A steel closing plate is fixed immediately beneath the risers angled to the rake of the terrace.
Steel is specified as S235 in accordance with BS EN 10025 Hot rolled products of structural steels. The polyurethane core is produced from polyol and isocyanate
Fire resistance is achieved by the addition of fire protection using stone mineral wool insulation board (see table 3) fixed beneath the completed terraces. SPS Terraces are intended for use in permanent and temporary grandstand structures in the UK. The individual step units are connected together to form terraces in such a way that they can be dismantled and reassembled at another location.
Certificate No: 154/11 Certificated Products SPS Bubble Core Floors
SPS (Sandwich Plate System) Bubble Core Floors are built up from a number of individual SPS Plates laid side by side and fixed to supporting steel located under each longitudinal joint in the direction of span. SPS Plates are of sandwich construction and comprise upper and lower steel plates bonded to a voided polyurethane elastomer core. Voids in the core are formed by the inclusion of hollow polypropylene spheres (nominal 50mm diameter). The structural performance of the SPS Bubble Core Floor is achieved by the composite action of the SPS Plates and the supporting steel beams. SPS Plate units are a maximum of 3m wide by 9m long.
Cert. No. 154/11
This certificate reports on the outcome of specified tests on defined construction configurations. It provides design data relating to that construction for use by structural engineers competent in the design of steel structures. The tested construction incorporated three 9m x 3m SPS Plates assembled to form a 9m x 9m floor supported on a perimeter framework of rolled steel sections with proprietary fabricated steel beams providing intermediate support at plate junctions (see Figure 1). The SPS Plates were each 60mm thick, having a 50mm core sandwiched between two 5mm steel plates. Fire protection shall be provided by means of stone mineral wool insulation board fixed immediately beneath the SPS Plates and supporting steel beam construction. The laboratory airborne and impact (acoustic) performance of the system has been determined for a number of different configurations.
20 Nov 2011
517
PART 5: SECTION 3 FLOORING SYSTEMS Certificated Products
Cert. No. The characteristics of the product and its method of application have been reviewed with respect to the current Building Regulations, British and European Standards and other publications in the United Kingdom in February 2010.
518
20 Nov 2011
PART 5: SECTION 4 GROUNDWORKS AND FOUNDATION SYSTEMS
The scope of products approved under this section is as follows: Groundworks and foundation products, systems and kits for domestic, commercial and industrial building applications manufactured from clay and cementitious based materials, plastics, timber, metals and composites to provide support for loading, water and gas resistance and thermal and fire protection over a specified design life.
Cordek Limited Spring Copse Business Park, Slinfold, West Sussex RH13 0SZ, United Kingdom Tel: +44 (0)1403 799600 • Fax: +44 (0)1403 791718 E-mail: [email protected] • Website: www.cordek.com Certificate No: 031/96 Certificated Products Ventform Panels
Ventform panels have been assessed to confirm their suitability for use as a ventilation void former for the support of cast in-situ concrete slabs for either suspended or ground supported floors and to facilitate ventilation of hazardous gases. Ventform panels also provide insulation to improve thermal performance of ground floor construction.
Cert. No. 031/96
Saint-Gobain Weber Limited Dickens House, Enterprise Way, Flitwick, Beds MK45 5BY, United Kingdom Tel: +44 (0) 1525 722101 • Fax: +44 (0) 1525 718988 E-mail: [email protected] • Website: www.netweber.co.uk Certificate No: 052/98 Certificated Products Weber Leca Insulation Fill
20 Nov 2011
Weber Leca Insulation Fill has been assessed to confirm its suitability, within limitations, for use as an insulation and hardcore material below ground floors. The product is a graded lightweight expanded clay aggregate. In a construction it is overlaid with a specified waterproofing membrane and stabilising wire mesh layer (both items not covered by this certificate).
Cert. No. 052/98
519
PART 5: SECTION 5 MEMBRANES
The scope of products approved under this section is as follows: Membranes for buildings manufactured from polymers, bitumen, rubbers and metal foil in liquid applied or sheet form for use as continuous or discontinuous layers for the control of the movement of air, liquid water, water vapour, carbon dioxide, radon and methane through floor, wall, roof and internal elements of buildings and structures over a specified design life.
DuPont de Nemours (Luxembourg) S.a.r.l. Rue General Patton, L-2984, , Luxembourg Tel: +352 3666 5736 E-mail: [email protected] • Website: www.tyvek.co.uk Certificate No: 155/10 Certificated Products Tyvek® UV Facade Underlay 2524B
Tyvek® UV Facade Underlay 2524B is intended to be used in Façade construction as a secondary, water vapour permeable, weather resistant layer, for protection against wind driven rain or snow and the ingress of dust. It has been designed for use with open or ventilated cladding constructions.
Cert. No. 155/10
Tyvek® UV Facade 2524B is a UV and heat stabilised Type LR low resistance (breathable) polymeric underlay as defined in BS 5250 Code of practice for the control of condensation in buildings. It comprises a 2 layer laminate of high density polyethylene, and a polypropylene fleece. Tyvek® UV Facade 2524B is embossed black on the outer surface (as installed) and white on the inner surface.
Industrial Textiles & Plastics Ltd Stillington Road, Easingwold, York YO61 3FA, United Kingdom Tel: +44 (0)1347 825200 • Fax: +44 (0)1347 825222 E-mail: [email protected] • Website: www.itpltd.com Certificate No: 095/02 Certificated Products Powerbase MB 420 Gas Resistant Membrane
Powerbase MB 420 has been assessed to confirm its suitability for use as a gas and moisture resistant barrier for incorporation into the floor of a building to restrict the ingress of radon, methane and carbon dioxide from the ground in situations where there is a risk of contamination to the internal environment of the building.
Cert. No. 095/02
Certificate No: 124/07 Certificated Products Powerlon UltraPerm Breather Membrane
520
Powerlon UltraPerm Breather Membrane (Powerlon UltraPerm BM) has been assessed to determine that it can be used, with conditions, as a roof underlay for use in pitched warm and cold roof constructions with or without ventilators, as a secondary weather resistant layer, for protection against wind driven rain and snow, tile wind-uplift, and ingress of dust to satisfy or contribute towards satisfying the requirements of the Building Regulations within the United Kingdom and Ireland. Powerlon UltraPerm BM consists of a water resistant and breathable polypropylene film sandwiched between two polypropylene spunbonded layers and is a permeable low vapour resistance (type LR) roof underlay as defined by BS 5250 Code of practice for the control of condensation in buildings. It is available in different weights, between 85g/m 2 and 140g/m 2 .
Cert. No. 124/07
20 Nov 2011
PART 5: SECTION 5 MEMBRANES
Klober Limited Unit 6F, East Midlands Distribution Centre, Short Land, Castle Donington, Derbyshire DE74 2HA, United Kingdom Tel: +44 (0)1332 813050 • Fax: +44 (0)1332 814033 Certificate No: 105/03 Certificated Products Sepa® forte
Sepa® forte is a reinforced multi-layer membrane and is blue in colour on the upper side. It is suitable, within conditions, as a roof underlay for use in pitched roof construction, under slates or tiles as a secondary weather resistant layer, for protection against winddriven rain and snow, tile wind-uplift and ingress of dust. The underlay has good resistance to tearing during installation and remains flexible at low temperatures.
Cert. No. 105/03
Certificate No: ABP013 to BPS 7005 Issue 1.0 Certificated Products Sepa Light
Sepa Light is a UV and heat stabilised Type HR polymeric roof underlay. It comprises a polypropylene non-woven layer which is coated on one surface with a continuous film of polyethylene/polypropylene blend and is regarded as a high water vapour resistance (Type HR) underlay as defined in BS 5250 Code of practice for the control of condensation in buildings . Sepa Light is manufactured in rolls as shown below.
Cert. No. ABP013
Product dimensions CharacteristicNominal value Roll length 25 and 50 m Roll width1.0, and 1.5 m Sepa Light is dark grey with the brand name and unique production code printed on the upper surface (as installed) and blank on the lower surface. Sepa Light is intended to be used in pitched roofs as a secondary, impermeable, weather resistant layer, for protection against wind driven rain or snow and the ingress of dust. It is installed beneath roof tiles or slates in roofs constructed in accordance with BS 5534 Code of practice for slating and tiling (including shingles).
Visqueen Building Products Maerdy Industrial Estate, Rhymney, Tredegar NP22 5PY, United Kingdom Tel: +44 (0)1685 840672 • Fax: +44(0)1685 842580 E-mail: [email protected] • Website: www.visqueenbuilding.co.uk Certificate No: 083/01 Certificated Products Visqueen Radon Membrane
Visqueen Radon Membrane polyethylene sheet membrane has been assessed to confirm its suitability for use as part of a radon gas and moisture-resistant system for incorporation into the floor of a building in situations where there is a risk of contamination to the internal environment of the building arising from radon evolution from the ground.
Cert. No. 083/01
Certificate No: 112/04 Certificated Products Visqueen Eco-membrane
20 Nov 2011
Visqueen Eco-membrane re-cycled low density polyethene sheet membrane has been assessed to confirm its suitability for use as a damp proof membrane for incorporation into the floor of a building in situations where there is a risk of damage to the internal environment of the building arising from moisture from the ground.
Cert. No. 112/04
521
PART 5: SECTION 6 PRE-FABRICATED BUILDING SYSTEMS
The scope of products approved under this section is as follows: Building systems and kits of superstructure, basement and roofing structure for buildings as products, components and systems of wall, floor, roof and stairways, linings and finishes manufactured from gypsum, clay and cementitious based materials, plastics, timber, metals and composites for domestic and commercial applications over a specified design life.
Kingspan Limited (t/a Profiles and Sections) Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom Tel: +44 (0)1944 712000 • Fax: +44 (0)1944 710555 E-mail: [email protected] • Website: www.kingspanprofiles.com Certificate No: 118/06 Certificated Products Kingframe Building and Architectural Façade System
Cert. No. 118/06
The Kingframe Building and Architectural Façade Systems have been assessed to confirm suitability for use as building structures (KBS) and as infill construction to form external facades to steel or concrete framed single and multi storey buildings (AFS). The Kingframe Building System (KBS) comprises; load-bearing steel stud external wall frames incorporating specified insulation, load-bearing and non load-bearing internal wall frames incorporating specified insulation, steel and timber cassette floor panels, composite concrete floors and steel and timber cassette roof panels. The Architectural Façade System (AFS) comprises; non load-bearing steel stud wall frames incorporating specified insulation. The characteristics of the systems covered by this certificate are:
Structure Behaviour in relation to fire Weathertightness Thermal transmittance and condensation risk Acoustic performance Durability Factory production and quality control Practicality of site installation
The KBS and AFS systems are installed by Kingspan Ltd trained and approved installers. The KBS and AFS systems have been assessed for use with masonry, render, brick slip, rainscreen, timber and stone claddings (outside the scope of this certificate) which are not supplied by Kingspan Ltd but for which performance assessments have been made in relation to use with the KBS and AFS systems. The characteristics of The Kingframe Building and Architectural Façade Systems have been reviewed with respect to the current Building Regulations, British and European Standards and other publications in the United Kingdom and Ireland in January 2011.
Metsec Limited Broadwell Road, Oldbury, West Midlands B69 4HE, United Kingdom Tel: +44 (0)121 601 6000 • Fax: +44 (0)121 601 6126 E-mail: [email protected] • Website: www.metsec.com Certificate No: 110/04 Certificated Products Metframe and SFS Building System
522
The Metframe and SFS Building Systems have been assessed to confirm suitability, subject to the limitations of this certificate, for use in the construction of residential and commercial buildings in the UK with a floor no more than 18m from the ground unless
Cert. No. 110/04
20 Nov 2011
PART 5: SECTION 6 PRE-FABRICATED BUILDING SYSTEMS Certificated Products
Cert. No. otherwise stated in this certificate The loadbearing system either arrives on site in pre-made panels (Metframe) where connections are predominately bolted or is ‘stick-built’ on site (SFS) with connections predominately screw fixed. The non-loadbearing system (SFS) is ‘stick-built’ on site using screw fixed connections and is used to form non-loadbearing external walls in traditional superstructures. The Metframe and SFS Building Systems included within the scope of this certificate are listed below along with the materials or products (outside the scope of this certificate) for which the performance of the Metframe and SFS building systems have been assessed in typical building applications. Intermediate/separating floors: Cold formed galvanised steel Z-purlins Profiled metal decking to support in-situ poured concrete* Under cladding with 80mm Isowool 1000 insulation* Two 12.5mm layers of British Gypsum Fireline Board* Either over cladding with 5mm Ethafoam and 50mm concrete screed or Isolgomma R10 and 19mm Viroc board*. Cold-formed galvanised steel joists 75mm Isowool 1605 located between the joists* Under cladding with defined combinations of British Gypsum Wall and Fireline Boards* External wall panels (load bearing and non-load bearing): Cold-formed galvanised steel stud (SFS) and pre-fabricated panels (Metframe) Defined combinations of British Gypsum lining boards, cement particle board and Thermawall TW55 insulation board* Isowool Hitherm insulation between the studs. The panels form the inner leaf of a wall having a 50mm cavity* Outer leaf of conventional masonry construction* External wall panels (load bearing and non-load bearing): Cold-formed galvanised steel stud (SFS) and pre-fabricated panels (Metframe) Defined combinations of British Gypsum lining boards, cement particle board and Thermawall TW55 insulation board* Isowool Hitherm insulation between the studs. The panels form the inner leaf of a wall having a 50mm cavity* Outer leaf of conventional masonry construction* Internal wall panels (load bearing and non-load bearing): Cold-formed galvanised steel stud panels Defined combinations of British Gypsum lining boards*. Isowool 1000, 1200 and 1605 insulation between the studs*. * Materials/products supplied by others and outside the scope of this certificate The Metframe and SFS Building Systems which are designed on a site and project specific basis, are used with other building elements and products, that are supplied by others, to deliver specific building requirements. The design verification shall be carried out by a suitably qualified and experienced Metsec plc engineer and comply with relevant structural regulations, codes and standards in force in the UK at that time and including the Metsec plc Technical Manual. The structural adequacy of the Metframe and SFS Building Systems, including connection and foundation design, have not been assessed by BRE Certification as the design verification will be site and project specific. The characteristics of the system elements covered by this certificate are: Behaviour in relation to fire Weathertightness Thermal transmittance and condensation risk Acoustic performance Durability Factory production and quality control Practicality of site installation (with reference to Metsec plc Technical Manual). The structural adequacy of the Metframe and SFS building systems, including foundation design, has not been assessed by BRE Certification. The Metframe and SFS Building Systems are installed by Metsec plc Approved Installers.
20 Nov 2011
523
PART 5: SECTION 6 PRE-FABRICATED BUILDING SYSTEMS Certificated Products
Cert. No. The performance of the system depends on the quality of its installation. Whilst the installation manual has been examined by BRE Certification and a site installation observed to confirm that the system can be assembled satisfactorily following those installation instructions, the actual quality of installation achieved on specific sites is not covered by this certificate. The systems shall be installed by appropriately trained and experienced Metsec plc Approved Installers. When used as part of the external wall construction to framed superstructures (i.e.Timber BS 5268 Structural use of timber; Masonry BS 5628 Code of practice for the use of masonry, Steel BS 5950 Structural use of steelwork in building; Concrete BS 8110 Structural use of concrete with a masonry external surface (i.e. BS EN 771-1:2003 Specification for masonry units. Clay masonry units or previously BS 3921 Specification for clay bricks) the non-loadbearing SFS system may be used in buildings with a floor more than 18 metres from the ground. The load bearing site-built stick system (SFS) shall not be used for constructions over 3 storeys in height. Characteristics of the Metframe and SFS Building Systems have been reviewed with respect to the current Building Regulations, British and European Standards and other publications in the United Kingdom in April 2010.The assessment is described in the following pages, which form integral parts of this certificate and should be read in their entirety.
524
20 Nov 2011
PART 5: SECTION 7 BUILDING SYSTEMS FOR DWELLINGS
BRE Global has developed the BPS 2020 suite of standards to provide for approval of building systems for dwellings. The primary objective of this approval scheme is to encourage innovation whilst maintaining acceptable levels of safety and to create confidence in the development and use of building systems for dwellings, particularly those using Modern Methods of Construction (MMC).
Fusion Building Systems Fusion House, Scirocco Close, Moulton Park, Northamptonshire NN6 3HE, United Kingdom Tel: +44 (0)1604 490540 • Fax: +44 (0)1604 490549 E-mail: [email protected] • Website: www.fusionbuild.com Certificate No: ABP006 to BPS2020 Certificated Products Fusion Building System
The Fusion building system is a panelised light gauge steel building system for the construction of dwellings up to 6 storeys in height, and as the upper six storeys of a building which has a top floor height not more than 30m above ground level. In buildings with a traditional pitched roof no floor shall be more than 18m above ground level. The system comprises the following principal building elements.
Cert. No. ABP006
External Walls - the inner leaf of external walls consists of factory made loadbearing cold rolled light gauge steel sections with flame retardant expanded polystyrene insulation moulded into the body of the panel and forming an external layer to provide a hybrid construction. The Fusion building system has been assessed for use with conventional masonry cladding and specified internal plasterboard lining. Internal Walls - load bearing walls are formed using cold rolled light steel panels as described for external walls. Separating walls consist of two load bearing panels separated by a cavity with gable apex panels used in pitched roofs. Floors - upper floors are either of factory built cassette form using C section steel joists and steel channel rim sections covered with oriented strand board or site assembled, using C section steel joists supported at the ends by steel Z sections and covered with oriented strand board. Separating floors are designed as compartment floors and incorporate additional proprietary material to provide fire resistance and acoustic performance. Composite concrete/steel deck floors have also been assessed for use with the Fusion building system. Roofs - flat roofs are of factory built floor cassette form (as floors) suitable to support proprietary warm deck roof systems or traditional proprietary timber trussed rafter roofs.
Key Housing Limited 2 Sebastian Street, London EC1V 0HE, United Kingdom Tel: +44 (0)20 7687 6004 • Fax: +44 (0)20 7687 6002 E-mail: [email protected] • Website: ww.key-housing.co.uk Certificate No: ABP 010 to BPS 2020 Certificated Products Key Housing Building System
The Key Housing building system is a volumetric steel framed building system for the construction of dwellings up to 6 storeys in height with floors up to 18m above ground level. The system comprises the following principal building elements.
Cert. No. ABP 010
External Walls - Factory made insulated loadbearing volumetric building pods forming the inner leaf of external walls assembled from a combination of hot and cold rolled light steel C sections, (of various material thickness up to 3mm) with mineral fibre insulation. An internal lining of one or more layers calcium silicate board is added to provide the required period of fire resistance and a surface finish. External faces are lined with fibre cement boards. The volumetric modules incorporate brackets allowing steel wall ties to be fitted on site to tie external cladding systems to the Key Housing external wall panel.
20 Nov 2011
525
PART 5: SECTION 7 BUILDING SYSTEMS FOR DWELLINGS Certificated Products
Cert. No. The backing wall does not rely on the exterior cladding to provide water resistance and has been designed to accommodate a number of cladding systems. BRE report 267-819 provides information on the use of typical insulated render, brick skin and terracotta tile rainscreen applications which are outside the scope of the certificate. Internal Walls - load bearing walls are formed using cold rolled steel C sections. Separating walls incorporate a cavity and are formed by placing two steel C section panels adjacent to one another. Walls incorporate mineral fibre insulation and are lined on room faces with calcium silicate board. Floors - Upper floors are of factory built volumetric pod construction, the floor surface and supporting steel joists are part of the upper pod and the ceiling below is formed by the lower pod. Separating floors are designed as compartment floors and incorporate additional proprietary material, including calcium silicate board, to provide fire resistance and acoustic performance. Roof - Roof structures are formed by the top of the upper pod, used to form a flat roof structure (suitable to support a warm deck roof system outside the scope of the certificate) or a traditional pitched roof (formed of roof trusses with cladding, which is outside the scope of the certificate).
SIP Energy Ltd Athenry, , Co Galway, Ireland Tel: +353 (0)91 874290 • Fax: +353 (0)91 874295 E-mail: [email protected] • Website: [email protected] Certificate No: ABP 005/001 to BPS2020 Certificated Products SIP Energy Structurally Insulated Panel System
The SIP Energy Structurally Insulated Panel System (incorporating structurally insulated wall and roof panels) is a factory produced structurally insulated panel (SIP) system for the construction of dwellings up to 3 storeys in height. The system, shown in figures 1 to 5, comprises the following principal building elements;
Cert. No. ABP 005/001
1.1 External Walls - load bearing factory assembled wall panels comprising timber studs, OSB facings and extruded polystyrene insulation, bonded together by polyurethane adhesive. The key components of these panels are: - 15mm OSB sheathing - 100mm* internal timber stud framing** with XPS (Extruded Polystyrene) insulation infill between - 15mm OSB sheathing The panels are erected and fixed together on site using power driven 2.8mm by 63mm ringshank nails and screws. Preservative treated timber plates, bolted to the substructure, are used for accurate positioning and levelling. Panels interlock with adjacent panels and with location plates to provide a positive connection which is also sealed by application of sealant during installation. The walls have a breather membrane and conventional masonry cladding (provided by others) externally with a 50mm drained and vented cavity. Any other external cladding is outside the scope of this certificate. An internal lining of plasterboard is added (by others) to provide the required period of fire resistance and a surface finish. * Panels with thicker insulation are available ** Preservative treated timber can be used if requested. 1.2 Internal Walls - load bearing walls can be formed using the panels as described for external walls. Compartment walls between adjacent dwellings consist of two panels separated by a cavity as shown in Figure 5 1.3 Floors - floors are formed using conventional components such as I section joists with OSB decking. The OSB deck can be carried over the head of wall panels below to provide a connection to the wall. See figure 1 1.4 Roof - roofs can be formed using similar panels to the walls (with 125mm thickness insulation infill) or by using conventional roof trusses. When SIP Energy panels are used they are inclined to provide support to the roof underlay and battens which support the tile covering. A timber or steel beam (outside the scope of this certificate) is used to support the roof panels at the ridge. See figure 1
526
20 Nov 2011
PART 5: SECTION 7 BUILDING SYSTEMS FOR DWELLINGS Certificated Products
Cert. No. 1.5 Other items - Other items typically supplied with the SIP Energy system include DPCs, mineral wool insulation, cavity barriers, lining boards, acoustic sealant, ceiling battens, fixing plates, and foam sealant to fill joints. These are not covered by this certificate. The innovative elements covered by this certificate are: - The insulated wall panel which can also be used inclined to form a roof - Fixing brackets and straps for frame and foundation connections The non-innovative elements assessed for use with the above innovative elements - The internal wall and ceiling linings - Roof insulation applied between roof trusses - The timber based floor joists and decking - The masonry external wall cladding - The tile or slate roof cladding
20 Nov 2011
527
PART 5: SECTION 8 TRUSSED RAFTERS (TIMBER)
This scheme has now been withdrawn.
528
20 Nov 2011
PART 5: SECTION 9 THERMAL INSULATION SYSTEMS
The scope of products covered under this scheme is as follows: Thermal insulation products, systems and kits, with formed and formless materials, for domestic, commercial and industrial building applications manufactured from cellulose, mineral and natural fibre, clay and cementitious based materials, plastics, timber, metals and composites. These provide control of thermal movement through floor, wall, roof and internal elements of buildings, decoration, and weather resisting, fire and acoustic protection with and without mechanical and adhesive fixings, with continuous or discontinuous layers.
Euroform Products Limited The Heliport, Lyncastle Road, Appleton, Warrington, Cheshire WA44 4SN, United Kingdom Tel: +44 (0) 1925 860999 • Fax: +44 (0) 1925 860066 E-mail: [email protected] Certificate No: 147/08 Certificated Products U Foil 1BD/A-1 Single Foil Bubble Insulation and U Foil 1BD/A Double Foil Bubble Insulation
U Foil 1BD/A-1 (Single) and 1BD/A (Double) Foil Subble Insulation products have been assessed to confirm their suitability for use as insulation behind internal dry lining or for improving insulation to external cavity walls on the internal side of the weathering protection as partial fill cavity wall insulation for buildings with masonry or dense concrete walls. The products consist of aluminium foil faced polyethylene bubble film multilayer laminates.
Cert. No. 147/08
Certificate No: 148/08 Certificated Products U Foil VBF Vented Foil Bubble
U Foil VBF Vented Foil Bubble is a reflective insulation and vapour open cavity rain barrier and has been assessed to confirm its suitability for use as a thermal isolating layer for improving insulation to external cavity walls of timber frame construction in the United Kingdom. The product consists of an aluminium foil faced polyethylene bubble film laminate. U Foil VBF Vented Foil Bubble is installed against the inner leaf sheathing withing the cavity within the foil face o the clear cavity side.
Cert. No. 148/08
Yorkshire Building Services (Whitwell) Limited The Crags Industrial Estate, Morven Street, Creswell, Derbyshire S80 4AJ, United Kingdom Tel: +44 (0)8449910044 • Fax: +44 (0)8449910055 E-mail: [email protected] • Website: www.ybsinsulation.com Certificate No: 157/11 Certificated Products Products for Use in improving thermal insulation of walls & roofs
Yorkshire Building Services (Whitwell) Limited (YBS) produce a range of products for use in improving the thermal insulation of walls and roofs. This certificate covers the products below;
Cert. No. 157/11
Therma Close - Insulated cavity closer and damp proof barrier for use around openings in masonry cavity walls. Therma Close Type R - Insulated cavity closer and damp proof barrier for use around openings in masonry cavity walls. Therma-Flect EPS and Therma-Flect PIR (Wall Boards) - Partial fill cavity wall insulation for improving thermal insulation in external walls of masonry. Therma-Flect EPS and Therma-Flect PIR (Roof Boards) - Combined thermal insulation and protection against wind driven rain and snow for use under slates or tiles at rafter
20 Nov 2011
529
PART 5: SECTION 9 THERMAL INSULATION SYSTEMS Certificated Products
Cert. No. level. The bubble foil layer may be located above or below the rafter. Cavi-Mate EPS and Cavi-Mate Rock fibre cavity closers - Cavity closer providing a damp-proof barrier and thermal insulation for use around openings in masonry cavity walls. The characteristics of the products and their method of application have been reviewed with respect to the current Building Regulations, British and European Standards and other publications in the United Kingdom in November 2011.
530
20 Nov 2011
PART 5: SECTION 10 WALL AND ROOF CLADDING SYSTEMS
The scope of products covered under this scheme is as follows: Wall and roof cladding products, systems and kits for domestic, commercial and industrial building applications manufactured from metals, plastics, timber, glass, natural stone, clay and cementitious based materials and composites to provide decoration, and weather resisting, fire, thermal and acoustic protection.
Eurobrick Systems Limited Unit 7, Wilverley Trading Estate, Bath Road, Brislington, Bristol BS4 5NL, United Kingdom Tel: +44 (0)117 971 7117 • Fax: +44 (0)117 971 7217 E-mail: [email protected] • Website: www.eurobrick.co.uk Certificate No: 015/93 Reissue 2010 Certificated Products Eurobrick Insulated Brick Cladding System
The Eurobrick Insulated Brick Cladding System (Eurobrick System) comprises a composite backerboard formed from extruded polystyrene insulation board glued to a profiled polystyrene carrier sheet, brick slips, proprietary mortar and specified ancillary components. Finished walls have the appearance of traditional brickwork. Where specified a cavity can be incorporated into the construction behind the insulation by means of a supporting framework. This application is outside the scope of this certificate.
Cert. No. 015/93 reissue 2010
The Eurobrick System supplied by Eurobrick Systems Limited (Eurobrick) has been assessed to confirm its suitability for use as a weather resistant, thermal insulating external decorative finish for application to external vertical walls of new or existing residential and commercial buildings of masonry, dense concrete, timber or metal frame construction.
John Brash & Company Ltd The Old Shipyard, Gainsborough, Lincolnshire DN21 1NG, United Kingdom Tel: +44 (0)1427 613858 • Fax: +44 (0)1427 810218 E-mail: [email protected] • Website: www.johnbrash.co.uk Certificate No: ABP 003 to BRE Product Standard BPS 7002 Issue 1.0 Certificated Products JB RED Roof tiling battens
The JB RED Roof tiling battens are machine graded timber roof tiling battens with cross sectional dimensions of either 25mm x 38mm or 25mm x 50mm made from either European Redwood or Whitewood from a PEFC/FSC certified source. The battens are treated with a preservative specified to achieve a 60 year design life for the battens in accordance with BS 8417 and BS EN 599-1. The preservative supplier provides a 60 year warranty.
Cert. No. ABP 003
Individual battens are marked as follows: For 25mm x 38mm redwood battens: JOHN BRASH 25x38 PNSY BS5534 JBRED For 25mm x 50mm redwood battens: JOHN BRASH 25x50 PNSY BS5534 JBRED For 25mm x 38mm whitewood battens: JOHN BRASH 25x38 WPCA BS5534 JBRED For 25mm x 50mm whitewood battens: JOHN BRASH 25x38 WPCA BS5534 JBRED The battens are intended for use as part of a timber roofing structure to support concrete, clay, fibre-cement, natural slate or metal roofing tiles and/or bitumen or wooden shingles. The preservative treatment applied does not provide resistance to attack by the House Longhorn beetle.
20 Nov 2011
531
PART 5: SECTION 10 WALL AND ROOF CLADDING SYSTEMS
Marmorit (UK) GmbH 1 Portview Road, Avonmouth, Bristol BS11 9LS, United Kingdom Tel: +44 (0)117 982 1042 E-mail: [email protected] • Website: www.marmorit.co.uk Certificate No: 059/99 Certificated Products Marmorit Warm Wall Insulation Systems
1) 2) 3) 4)
Cert. No. 059/99
Warm-wall polystyrene tongue and grooved Warm-wall mineral fibre wool Warm-wall mineral fibre volamit Warm-wall rail system
polystyrene tongue and grooved mineral fibre wool mineral fibre volamit rail system External Wall Insulation
Marmorit Warm-Wall External Wall Insulation Systems are External Thermal Insulation Composite Systems (ETICS) and have been assessed to confirm their suitability for use as external decorative and thermal insulating systems for buildings of masonry or dense concrete walls in the United Kingdom. The systems consist of an insulant of expanded polystyrene boards or mineral fibre slabs with a range of cementitious based coloured coating finishes. The method of providing insulation and fixing to the substrate determines which of the Marmorit Warm-Wall systems is used.
Certificate No: 081/01 Certificated Products Marmorit Render Systems
Marmorit render systems (finish renders applied to a basecoat) have been assessed to confirm their suitability for use as a weather resistant external decorative coating on new and existing walls of either fired-clay brick, or of lightweight or dense aggregate concrete block, masonry or dense concrete construction or over existing rendering using these products. They are one coat or two coat ready coloured render system providing various surface textures and colours.
Cert. No. 081/01
PermaRock Products Limited Jubilee Drive, Loughborough, Leicestershire LE11 5TW, United Kingdom Tel: +44 (0)1509 262924 E-mail: [email protected] Certificate No: 029/95 Certificated Products PermaRock External Wall Insulation System
The system has been assessed to confirm its suitability as an external decorative and thermal insulating system for use on masonry, dense and no-fines concrete, timber frame or steel frame walls. It consists of an insulant of mineral wool or expanded polystyrene boards with a range of polymer modified render and aggregate finishes, or fired clay brick slips.
Cert. No. 029/95
Certificate No: 041/97 Certificated Products PermaRock Phenolic External Wall Insulation System
532
The system has been assessed to confirm its suitability for use as an external decorative and thermal insulation system for masonry or concrete walls. The system consists of an insulant of phenolic foam and a range of polymer-modified render and aggregate finishes.
Cert. No. 041/97
20 Nov 2011
PART 5: SECTION 10 WALL AND ROOF CLADDING SYSTEMS
Wienerberger Limited Wienerberger House, Brooks Drive, Cheadle Royal, Cheadle, Cheshire SK8 3SA, United Kingdom Tel: +44(0)161 491 8200 • Fax: +44(0)161 491 1270 E-mail: [email protected] • Website: www.wienerberger.co.uk Certificate No: 082/01 Certificated Products Corium
Corium has been assessed to confirm its suitability for use as an external weather resistant and decorative brick cladding for application to external vertical walls of new or existing buildings of masonry, dense concrete, timber or metal frame construction in the UK. The system consists of horizontally mounted steel channel profiles, fitted externally with brick clay tiles with mortar pointing, to provide a brickwork finish.
Cert. No. 082/01
Z-Led Limited Plymouth Avenue, Brookhill Industrial Estate, Pinxton, Nottingham NG16 6NS, United Kingdom Tel: +44 (0)1773 814113 • Fax: +44 (0)1773 814115 E-mail: [email protected] • Website: www.z-led.com Certificate No: 153/10 Certificated Products Aluflash - coated aluminium flashing
Aluflash is an aluminium based weathering flashing material. It comprises solvent lacquer coated embossed aluminium sheet material to BS EN 1396:2007 Aluminium and aluminium alloys. Coil coated sheet and strip for general applications. Specifications with a self-adhesive butyl backing for adhesion to roof coverings or masonry. It is available in flat or cross corrugated versions.
Cert. No. 153/10
Aluflash is intended for use fully supported as stepped, abutment, chimney and saddle flashings, to line valleys, box and secret gutters and at upstands to rooflights and solar panels. Cross corrugated Aluflash is intended for use where the flashing needs to be moulded over and around complex shapes.
20 Nov 2011
533
PART 5: SECTION 11 WALLING, ROOFING AND PARTITION SYSTEMS
The scope of products covered under this scheme is as follows: Walling, roofing and partition products, systems and kits for building and construction applications manufactured from gypsum, clay and cementitious based materials, plastics, timber, metals and composites to provide loadbearing or non loadbearing structures and finishes, decoration and weather resisting, fire, thermal and acoustic protection.
Kingspan Limited (t/a Profiles and Sections) Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom Tel: +44 (0)1944 712000 • Fax: +44 (0)1944 710555 E-mail: [email protected] • Website: www.kingspanprofiles.com Certificate No: 118/06 Certificated Products Kingspan Building and Architectural Façade Systems
The Kingframe Building and Architectural Façade Systems have been assessed to confirm suitability for use as building structures (KBS) and as infill construction to form external facades to steel or concrete framed single and multi storey buildings (AFS).
Cert. No. 118/06
The Kingframe Building System (KBS) comprises; load-bearing steel stud external wall frames incorporating specified insulation, load-bearing and non load-bearing internal wall frames incorporating specified insulation, steel and timber cassette floor panels, composite concrete floors and steel and timber cassette roof panels. The Architectural Façade System (AFS) comprises; non load-bearing steel stud wall frames incorporating specified insulation. The characteristics of the systems covered by this certificate are: · · · · · · · ·
Structure Behaviour in relation to fire Weathertightness Thermal transmittance and condensation risk Acoustic performance Durability Factory production and quality control Practicality of site installation
The KBS and AFS systems are installed by Kingspan Ltd trained and approved installers. The KBS and AFS systems have been assessed for use with masonry, render, brick slip, rainscreen, timber and stone claddings (outside the scope of this certificate) which are not supplied by Kingspan Ltd but for which performance assessments have been made in relation to use with the KBS and AFS systems. The characteristics of The Kingframe Building and Architectural Façade Systems have been reviewed with respect to the current Building Regulations, British and European Standards and other publications in the United Kingdom and Ireland in January 2011.
Logix UK Limited (Simplipac) 57 Balena Close, Creekmoor Industrial Estate, Poole, Dorset BH17 7DG, United Kingdom Tel: +44 (0)1202 694 259 • Fax: +44 (0)1202 600 640 E-mail: [email protected] • Website: www.logix.uk.com Certificate No: 122/06 Certificated Products Logix ICF Blocks
534
Logix ICF blocks have been assessed to confirm, within limitations, their suitability as a permanent Insulating Concrete Formwork (ICF) system. The forms of the system can be partly assembled off site (panelised) or fully assembled on site (in-situ) to produce a
Cert. No. 122/06
20 Nov 2011
PART 5: SECTION 11 WALLING, ROOFING AND PARTITION SYSTEMS Certificated Products
Cert. No. permanent formwork (shuttering), which is filled with a defined concrete mix and steel reinforcement where required. The resultant concrete walls with expanded polystyrene (EPS) panels either side can be used as either load-bearing or non load-bearing insulated walls in residential or commercial buildings. Only walls where the height of the top floor above ground, in a building or separated part of a building is not more than 18m are covered by this certificate. The forms comprise of two EPS panels each having a thickness of 70mm. They are held apart at either: 100mm (Logix4), or 159mm (Logix6) or 203mm (Logix8) forms, by proprietary polypropylene ties moulded into the EPS panels at 203mm centres. The forms have a nominal height of 203mm (half height) or 406mm (full height). The lengths of the forms are typically 1219mm. The forms are produced in straight, 45 o or 90 o plan sections. Both internal and external faces of the finished walls require the addition of a protective cladding not covered by this certificate. The characteristics of the product and the method of application have been reviewed with respect to the Building Regulations current in the United Kingdom. The assessment has referred to British Standards and other publications current when this certificate was issued.
20 Nov 2011
535
PART 5: SECTION 12 CONSERVATION OF FUEL AND POWER
Products covered under this scheme have been demonstrated to aid the conservation of fuel and power in buildings.
Energy Control Systems Ltd Pipsden Lodge, Rye Road, Hawkhurst, Kent TN18 5DN, United Kingdom Tel: +44 (0)1580 753682 Website: www.energy-control-systems.no Distributed and Installed by Dynamic Energy Products Ltd Fig Tree House, Dymchurch Road, St Mary's Bay, Kent TN29 0HF, United Kingdom Tel: +44 (0)1797 367400 • Fax: +44 (0)1797 367400 E-mail: [email protected]
Certificate No: CFP 348 Certificated Products Burner Management Unit BM1 and Dynamic Burner Management Unit DBMU
536
The Burner Management is designed to modify the burner-firing pattern of conventional commercial boilers and water heaters (with 40kW input or greater) to minimise wasteful over-firing. The effectiveness of the Burner Management Unit has been tested on a typical open-flued commercial boiler (rated at 63kW) subject to a fully repeatable load pattern over a course of back-to-back tests with the Burner Management Unit both in and out of circuit.
Cert. No. CFP 348
20 Nov 2011
Part 6 MANAGEMENT SYSTEM CERTIFICATION
PART 6: MANAGEMENT SYSTEM CERTIFICATION Introduction We offer approval to the three key management system standards for: Quality - ISO 9001 Now one of the world’s leading management system standards, ISO 9001 gives confidence to customers that the businesses they trade with have consistent levels of quality and service. Environmental Management - ISO 14001 Approval to ISO 14001 demonstrates a company’s commitment to the environment and provides an assurance to the public, regulators and purchasers that its environmental policies and procedures are effective. Health and Safety - BS OHSAS 18001 This is a specification that helps to fully integrate health and safety into company policies and working practices. It also signals to architects, clients, insurers and specifiers that a company takes its health and safety responsibilities seriously. As well as providing approval to each individually, we offer an integrated service to companies wanting approval under two or more of these management system standards.
538
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Approval of a Quality Management System demonstrates that a company’s internal systems and processes are in place and operating as intended. It also measures performance in delivering products or services to an agreed standard. Third party approval is an independent review of a particular area of a company’s activities, which leads to improved processes and increased consumer confidence, and can help to reduce costs. Under the International Standard, ISO 9001, the certificate identifies which parts of a company’s activities are covered, and must include design if this is part of its operation. This scheme is for companies whose Quality Management Systems have been designed to meet the requirements of ISO 9001. For companies that already have a certificated Quality Management System assessed to ISO 9001, we offer approval of the factory production control processes applicable to the products we approve, and these are detailed in the entries listed where that option has been taken. The entries in this section define the scope of activities that have been assessed under the management system. Unlike our product approval schemes, which relate to specific products and services, Quality Management Systems approval can encompass the complete scope of a firm's activities at that particular address. However, it is important to understand that ISO 9001 does not provide an assurance to the user or specifiers that actual products or services conform to requirements, since no testing or cross checking of conformity to product or service standards is involved. Therefore, no marking of specific products or installations is permitted. For companies operating in the fire and security areas with LPCB product or service approvals, our ISO 9001 approval is given in the name of LPCB. Where companies do not require LPCB product or service certification, then all certificates are issued in the name of BRE Global Limited.
2M KABLO SAN. ve TIC. A.S. Sanayi Mahallesi, 1678 Sokak No: 3, 34511 Esenyurt, Istanbul, Turkey Tel: +90 212 672 7314 • Fax: +90 212 672 7312 E-mail: [email protected] • Website: www.2mkab.com Also at: Perpa Ticaret Merkezi, A Blok Kat:8, No.707, Okmeydani, Istanbul, Turkey Quality System Cert. No. 711 Assessed to ISO 9001:2008 Scope: Design and manufacture of electric cables for use in installations that require safety in the event of fire.
A & F Sprinklers Limited Atrium House, 574 Manchester Road, Blackford Bridge, Bury, Lancashire BL9 9SW, United Kingdom Tel: +44 (0)845 505 1550 • Fax: +44 (0)845 505 1660 E-mail: [email protected] • Website: www.afsprinklers.co.uk Quality System Cert. No. 049 Assessed to ISO 9001:2008 Scope: Design and installation of fire sprinkler and water spray systems.
20 Nov 2011
539
PART 6: SECTION 1 QUALITY SYSTEMS
A M Profiles Limited Hardwick View Road, Holmewood Industrial Estate, Holmewood, Chesterfield, Derbyshire S42 5SA, United Kingdom Tel: +44 (0)1246 856000 • Fax: +44 (0)1246 855105 E-mail: [email protected] Quality System Cert. No. 808 Assessed to ISO 9001:2008 Scope: Manufacturing and installation of architectural aluminium and composite glazing.
A Steadman & Son (a division of SIG Trading Ltd), Warnell, Welton, Carlisle, Cumbria CA5 7HH, United Kingdom Tel: +44 (0)16974 78277 • Fax: +44 (0)16974 78530 E-mail: [email protected] • Website: www.steadmans.co.uk Quality System Cert. No. 635 Assessed to ISO 9001:2008 Scope: Manufacture of AS35 sandwich roof and wall panels. Manufacture of cold rolled section, including purlins, facias and fittings associated with wall and roof panels.
A.C. Plastic Industries Limited Unit J Loddon Business Centre, Roentgen Road, Basingstoke, Hants RG24 8NG, United Kingdom Tel: +44 (0)1256 329334 • Fax: +44 (0)1256 817862 E-mail: [email protected] • Website: www.ac-plastics.com Quality System Cert. No. 065 Assessed to ISO 9001:2008 Scope: Manufacture and installation of hot press moulded GRP sectional water storage tanks.
A.M. Fire Systems Limited Red Brook Mill, Bury Road, Rochdale OL11 4EE, United Kingdom Tel: +44 (0)1706 639439 • Fax: +44 (0)1706 347733 E-mail: [email protected] Quality System Cert. No. 357 Assessed to ISO 9001:2008 Scope: Design and installation of fire sprinkler, water spray and foam systems.
Abbot Fire Group Limited Abbots Barn, Radclive Road, Gawcott, Buckingham MK18 4AA, United Kingdom Tel: +44 (0)870 844 1666 • Fax: +44 (0)870 844 1777 E-mail: [email protected] Quality System Cert. No. 586 Assessed to ISO 9001:2008 Scope: Installation and servicing of portable fire extinguishers. Installation and servicing of kitchen suppression systems.
540
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
AccentHansen Greengate Industrial Park, Greengate, Middleton, Manchester M24 1SW, United Kingdom Tel: +44 (0)161 284 4100 • Fax: +44 (0)161 655 3119 E-mail: [email protected] • Website: www.servicehansen.com Quality System Cert. No. 021 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of industrial doors, security doors and fire doors.
Actionair Ruskin Air Management, Joseph Wilson Industrial Estate, South Street, Whitstable, Kent CT5 3DU, United Kingdom Tel: +44 (0)1227 276100 • Fax: +44 (0)1227 264262 E-mail: [email protected] • Website: www.actionair.co.uk Quality System Cert. No. 017 Assessed to ISO 9001:2008 Scope: The design, manufacture and supply of fire protection and air distribution products including: Electrically or pneumatically operated fire smoke dampers; Thermal release or electro magnetic release curtain fire dampers; Manually, electrically or pneumatically operated volume control and shut off dampers; Fan coil units; Control systems and ancillary products.
AD Sprinkler Protection Limited 2/8 Heaton Mill, Grey Street, Denton, Manchester M34 3RG, United Kingdom Tel: +44 (0)161 336 0001 • Fax: +44 (0)161 336 6608 E-mail: [email protected] • Website: www.adsprinklers.co.uk Quality System Cert. No. 916 Assessed to ISO 9001:2008 Scope: Design, installation and service of fire sprinkler systems.
Advanced Electronics Limited 34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United Kingdom Tel: +44 (0) 1226 737 465 • Fax: +44 (0) 1226 737 469 E-mail: [email protected] • Website: www.Advel.co.uk Also at: 2 Claycliffe Office Park, Whaley Road, Barnsley, South Yorkshire S75 1HT, United Kingdom Quality System Cert. No. 544 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection panels, emergency lighting and safety control equipment.
AEI Cables Limited Birtley, Chester-le-Street, Co. Durham DH3 2RA, United Kingdom Tel: +44 (0)191 410 3111 • Fax: +44 (0)191 410 8312 E-mail: [email protected] • Website: www.aeicables.co.uk Quality System Cert. No. 221 Assessed to ISO 9001:2008 Scope:
20 Nov 2011
541
PART 6: SECTION 1 QUALITY SYSTEMS Design and manufacture of electric cables for use in fire alarm installations.
Alliance Valves and Piping Supplies Limited 'AVPS' Unit 2, Royd Business Park, Dyehouse Lane, Brighouse, West Yorkshire HD6 1LL, United Kingdom Tel: +44 (0)1484 401880 • Fax: +44 (0)1484 401881 E-mail: [email protected] • Website: www.alliancevalves.co.uk Quality System Cert. No. 797 Assessed to ISO 9001:2008 Scope: Supply of process and instrumentation valves fittings as associated for the oil, petrochemical and associated sectors.
Alpine Fire Engineers Limited Sovereign House, Barehill Street, Littleborough, Lancashire OL15 9BL, United Kingdom Tel: +44 (0)1706 838200 • Fax: +44 (0)1706 838020 E-mail: [email protected] • Website: www.alpinefire.co.uk Quality System Cert. No. 283 Assessed to ISO 9001:2008 Scope: Design, service and installation of fire sprinkler systems.
Aluroll Limited Mile Oak Industrial Estate, Maesbury Road, Oswestry, Shropshire SY10 8GA, United Kingdom Tel: +44 (0)800 977 8975 • Fax: +44 (0)1691 671 482 E-mail: [email protected] • Website: www.aluroll.co.uk Quality System Cert. No. 931 Assessed to ISO 9001:2008 Scope: Design, manufacture and fabrication of security shutters and garage doors and assembly and supply of photovoltaic systems.
AMPAC Europe Limited Unit 18 Networkcentre, Yorkshire Way, Westmoor Park, Doncaster DN3 3GW, United Kingdom Tel: +44 (0)1302 833522 • Fax: +44 (0)1302 835021 E-mail: [email protected] • Website: www.ampac.net Quality System Cert. No. 952 Assessed to ISO 9001:2008 Scope: The marketing, assembly and distribution of fire detection and emergency warning products and associated training.
Ampac Security Products Limited Saxon Way, Melbourn, Royston, Hertfordshire SG8 6DN, United Kingdom Tel: +44 (0)1763 261900 • Fax: +44 (0)1763 261234 Website: www.ampaconline.com Quality System Cert. No. 822 Assessed to ISO 9001:2008 Scope: The manufacture of tamper evident polythene security bags and envelopes.
542
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Andreu Barbera S.L. Poligono Fuente Del Jarro, C/Ciudad De Sevilla, 20, 46988 Paterna, Valencia, Spain Tel: +34 96134 3100 • Fax: +34 961 34 0859 E-mail: [email protected] • Website: www.andreu.es Quality System Cert. No. 922 Assessed to Factory Production Control to PN 111 Scope: Design and production of metallic door sets and accessories.
Ansul Incorporated One Stanton Street, Marinette, Wisconsin 54143-2542, United States Tel: +1 715 735 7411 • Fax: +1 715 732 3477 Website: www.ansul.com Quality System Cert. No. 591 Assessed to ISO 9001:2008 Scope: Design and manufacture of restaurant fire protection systems and fire suppression wet agents.
Anvil International Inc. 1411 Lancaster Avenue, Columbia, Pennsylvania 17512, United States Tel: +1 717 684 4400 • Fax: +1 717 684 2131 Website: www.anvilintl.com Quality System Cert. No. 119 Assessed to ISO 9001:2008 Scope: Manufacture of pipe couplings fittings and valves. Malleable and gray iron threaded fittings and pipe hangers.
Anvil International Inc. 2870 Old Jackson Road, Henderson, Tennessee 38340, United States Tel: +1 731 989 3551 • Fax: +1 731 989 4144 Quality System Cert. No. 177 Assessed to ISO 9001:2008 Scope: Manufacture of pipe hangers. Metal stamping and fabrication.
Apollo (Beijing) Fire Products Co Ltd No. 5, Industrial District North-West Jia, Jiugong Town Daxing District, Beijing 100076, China Tel: +86 10 8361 7122 • Fax: +86 10 8361 7017 E-mail: [email protected] Quality System Cert. No. 1032 Assessed to ISO 9001:2008 Scope: Design, manufacture, service and repair of fire detectors and alarm system components.
20 Nov 2011
543
PART 6: SECTION 1 QUALITY SYSTEMS
Apollo Fire Detectors Limited 36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom Tel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754 E-mail: [email protected] Quality System Cert. No. 010 Assessed to ISO 9001:2008 Scope: Design, manufacture, service and repair of fire detectors for commercial/industrial applications.
APW Fire Protection Limited Unit A, Marlfield Factory, Front Road, Drumbo, Lisburn BT27 5JY, United Kingdom Tel: +44 (0)28 90827046 • Fax: +44 (0)28 90827049 E-mail: [email protected] Quality System Cert. No. 866 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
ArcelorMittal Construction Belgium Zone Industrielle de Martinrou, 21b rue de Berlaimont, Fleurus, Belgium Tel: +32 (0) 718 70540 • Fax: +32 (0) 718 70541 Website: www.arcelormittal.com Quality System Cert. No. 737 Assessed to ISO 9001:2008 Scope: Sales and manufacture of mineral wool insulation panels for construction.
ArcelorMittal Construction Belgium NV Lammerdries 8, Industrieterrein Geel West Z4, B-2440 Geel, Belgium Tel: +32 14563943 • Fax: +32 14563952 E-mail: [email protected] • Website: www.arclad.be Quality System Cert. No. 939 Assessed to Factory Production Control to PN 111 Scope: Production of sandwich panels for industrial and utility buildings.
Argus Fire Protection Company Limited Hendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA, United Kingdom Tel: +44 (0)1384 376256 • Fax: +44 (0)1384 393955 E-mail: [email protected] • Website: www.argusfire.co.uk Quality System Cert. No. 011 Assessed to ISO 9001:2008 Scope: Design and installation of fire sprinkler, water spray and foam systems. Installation, commissioning and servicing of fire detection and alarm systems.
544
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Argus-Spectrum Co 65 Serdobolskaya St, St. Petersburg 197342, Russian Federation Tel: +7 812 7037500 • Fax: +7 812 7037501 E-mail: [email protected] • Website: www.argus-spectr.ru Quality System Cert. No. 603 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire and security alarm system components
Armstrong Priestley Limited Seventy Seven, Holbeck Lane, Leeds LS11 9UL, United Kingdom Tel: +44 (0)113 3944040 • Fax: +44 (0)113 3944041 E-mail: [email protected] • Website: www.armstrongpriestley.co.uk Quality System Cert. No. 109 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler, water spray and foam systems, hydrants and hose reels. Fabrication of pipework for fire sprinkler systems.
Ascot Doors Limited Britannia Way Industrial Park, Union Road, Bolton BL2 2HE, United Kingdom Tel: +44 (0)1204 545801 • Fax: +44 (0)1204 545800 E-mail: [email protected] • Website: www.ascotdoors.co.uk Quality System Cert. No. 131 Assessed to ISO 9001:2008 Scope: Manufacture, installation, servicing and repair of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters.
Ashvale Fire Services Limited Ashvale House, Fitzroy Street, Ashton-under-Lyne, Lancashire OL7 0JG, United Kingdom Tel: +44 (0)161 343 1090 • Fax: +44 (0)161 343 3732 E-mail: [email protected] • Website: www.ashvalefireservices.com Quality System Cert. No. 275 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
ASLR Fabrication Services Limited Opal Way, Stone Business Park, Stone, Staffordshire ST15 0SS, United Kingdom Tel: +44 (0)1785 286060 • Fax: +44 (0)1785 818728 E-mail: [email protected] • Website: www.aslr.co.uk Quality System Cert. No. 1072 Assessed to ISO 9001:2008 Scope: Manufacture and supply of pre fabricated pipework for the fire protection, building services, water and process engineering industries.
20 Nov 2011
545
PART 6: SECTION 1 QUALITY SYSTEMS
ATOM KABLO SANAYI VE TICARET A.S. Ankara Karayolu 6. Km, Akkale Bedesi, Denizli 20155, Turkey Tel: +90 258 274 63 52 • Fax: +90 258 274 64 31 E-mail: [email protected] • Website: www.atom.com.tr Quality System Cert. No. 905 Assessed to Factory Production Control to PN 111 Scope: The manufacture and suppy of electric cables and wires, including cables used for installations which require safety in the event of fire.
Attenborough Doors Limited Merlin Way, Quarry Hill Industrial Estate, Ilkeston, Derbyshire DE7 4RA, United Kingdom Tel: +44 (0)115 9300815 • Fax: +44 (0)115 9448930 E-mail: [email protected] • Website: www.attenboroughdoor.co.uk Quality System Cert. No. 145 Assessed to ISO 9001:2008 Scope: Manufacture and installation of industrial rolling shutters and fire rolling shutters.
Automatic Fire Control Limited Unit 7 Kingsdown Orchard, Hyde Road, Swindon SN2 7RR, United Kingdom Tel: +44 (0)1793 821588 • Fax: +44 (0)1793 821587 E-mail: [email protected] Quality System Cert. No. 101 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler and water spray systems.
Bahra Cables Company CPC Industrial Park, Bahra, Jeddah 21432, Kingdom of Saudi Arabia Tel: +966 25911115, (Toll Free) 8001248111 • Fax: +966 25915683 E-mail: [email protected] • Website: www.bahra-cables.com Quality System Cert. No. 1069 Assessed to Factory Production Control to PN 111 Scope: Manufacture of single core fire resistant cables tested to BS 6387:1994 Cat CWZ. Conductor cross sectional area 2.5mm2 - 25mm2.
Bailey & Mackey Limited Baltimore Road, Birmingham B42 1DE, United Kingdom Tel: +44 (0)121 357 5351 • Fax: +44 (0)121 357 8319 E-mail: [email protected] • Website: www.baileymackey.com Quality System Cert. No. 085 Assessed to ISO 9001:2008 Scope: Design and manufacture of calibrated pressure gauges, pressure switches, pressure transducers and vapour pressure temperature gauges. Repair and re-calibration of pressure gauges, pressure switches, pressure transducers and vapour pressure temperature gauges, in the range of absolute vacuum up to 1000 bar gauge, and temperature range of 20 degrees celsius up to 200 degrees celsius.
546
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Balmoral Sectional Tanks Limited (A Division of Balmoral Group Holdings Limited), Balmoral Park, Loirston, Aberdeen AB12 3GY, United Kingdom Tel: +44 (0)1224 859000 • Fax: +44 (0)1224 859123 E-mail: [email protected] • Website: www.balmoraltanks.com Quality System Cert. No. 445 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of hot press moulded GRP sectional water storage tanks.
Bangkok Cable Co Limited 187/1 Rajdamri Road, Lumpinee, Pathumwan, Bangkok 10330, Thailand Tel: +662 254 4550 • Fax: +662 254 3859 E-mail: [email protected] Manufacture at: 93 Moo. 11, Suksawad Rd, Naiklongbangplakod, Prasamutchedee, Samutprakarn 10290, Thailand Quality System Cert. No. 576 Assessed to ISO 9001:2008 Scope: Design and manufacture of cables for use in installations that require safety in the event of fire.
BBC Fire Protection Limited St Florian House, Ayton Road, Wymondham, Norfolk NR18 0QH, United Kingdom Tel: +44 (0)1953 857700 • Fax: +44 (0)1953 857750 E-mail: [email protected] • Website: www.bbcfire.co.uk Quality System Cert. No. 346 Assessed to ISO 9001:2008 Scope: Installation, commissioning and servicing of fire detection and alarm systems.
Beijing Siemens Cerberus Electronics Limited No. 1, Feng Zhi Dong Lu, Xi Bei Wang, Haidian District, Beijing 100094, China Tel: +86 010 629 62255 • Fax: +86 010 629 87387 E-mail: [email protected] Quality System Cert. No. 531 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm equipment, intruder detection and alarm equipment. Design and manufacture of electronic and mechanical control products and systems for HVAC applications, room-controls and building automation.
Besseges Limited Riverside, Dukinfield, Cheshire SK16 4HE, United Kingdom Tel: +44 (0)161 308 3252 • Fax: +44 (0)161 339 5003 E-mail: [email protected] • Website: www.besseges.co.uk Quality System Cert. No. 071 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems. Fabrication of pipework.
20 Nov 2011
547
PART 6: SECTION 1 QUALITY SYSTEMS
Biamp Systems Corporation 9300 S.W. Gemini Drive, Beaverton, Oregon 97008, United States Tel: +1 503 718 9212 • Fax: +1 503 626 0281 Website: www.biamp.com Quality System Cert. No. 977 Assessed to ISO 9001:2008 Scope: Design and manufacturer of audio equipment including voice alarm control and indicating equipment.
Blue Shield Fire Protection Limited Blue Shield House, Queen Street, Tring, Hertfordshire HP23 6BQ, United Kingdom Tel: +44 (0)1442 828000 • Fax: +44 (0)1442 828001 E-mail: [email protected] • Website: www.blueshieldfire.co.uk Quality System Cert. No. 667 Assessed to ISO 9001:2008 Scope: Design, installation, service and repair of fire sprinkler systems.
Bolton Gate Co. Limited Waterloo Street, Bolton, Lancashire BL1 2SP, United Kingdom Tel: +44 (0)1204 871000 • Fax: +44 (0)1204 871049 E-mail: [email protected] • Website: www.boltongate.co.uk Quality System Cert. No. 026-2 Assessed to ISO 9001:2008 Scope: Manufacture and installation of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters.
Booth Industries Limited P.O. Box 50, Nelson Street, Bolton, Lancashire BL3 2AP, United Kingdom Tel: +44 (0)1204 366333 • Fax: +44 (0)1204 380888 E-mail: [email protected] • Website: www.booth-industries.co.uk Also at: Unit D, Lecturers Close, Bridgeman Street, Bolton BL3 6DG, United Kingdom Quality System Cert. No. 816 Assessed to ISO 9001:2008 Scope: Design and manufacture of blast walls, blast panels and blast doors. Manufacture of fire walls, fire panels, fire doors, security doors and industrial doors.
BPI Visqueen - Greenock 96 Port Glasgow Road, Greenock, Scotland PA15 2UL, United Kingdom Tel: +44 (0)1475 501100 • Fax: +44 (0)1475 743256 Website: www.bpipoly.com Quality System Cert. No. 521 Assessed to ISO 9001:2008 Scope: Manufacture of flame retardant plastic protection material.
548
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Bradbury Security Dunlop Way, Queensway Industrial Estate, Scunthorpe DN16 3RN, United Kingdom Tel: +44 (0)1724 271999 • Fax: +44 (0)1724 271888 E-mail: [email protected] • Website: www.bradburyuk.com Quality System Cert. No. 312 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of physical security products.
Braithwaite Engineers Limited Neptune Works, Uskway, Newport, South Wales NP20 2UY, United Kingdom Tel: +44 (0)1633 262141 • Fax: +44 (0)1633 250631 E-mail: [email protected] • Website: www.braithwaite.co.uk Quality System Cert. No. 103 Assessed to ISO 9001:2008 Scope: The design, supply and installation of sectional pressed steel tanks and glass reinforced plastic (GRP) cold water storage tanks, including the manufacture of custom GRP panels and components.
Brammall Inc. Doing business as Tyden Brooks Security Products, 409 Hoosier Drive, Angola, Indiana 46703, United States Tel: +1 260 665 3176 • Fax: +1 260 665 8309 E-mail: [email protected] • Website: www.tydenbrooks.com Quality System Cert. No. 779 Assessed to ISO 9001:2008 Scope: Design and manufacture of cargo security seals.
Britannia Kitchen Ventilation Limited 10 Highdown Road, Leamington Spa, Warwickshire CV31 1XT, United Kingdom Tel: +44 (0)1926 463540 • Fax: +44 (0)1926 463941 E-mail: [email protected] • Website: www.kitchen-ventilation.co.uk Quality System Cert. No. 1085 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of commercial and institutional kitchen ventilation canopies and associated equipment.
BSB Engineering Services Limited Unit E, Tribune Drive, Trinity Trading Estate, Sittingbourne, Kent ME10 2PD, United Kingdom Tel: +44 (0)1795 422609 • Fax: +44 (0)1795 429543 E-mail: [email protected] • Website: www.bsb-dampers.co.uk Quality System Cert. No. 828 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of fire dampers (fire curtains), fire smoke dampers, smoke control dampers and volume control dampers.
20 Nov 2011
549
PART 6: SECTION 1 QUALITY SYSTEMS
Burton Safes Limited Unit 12, Brockholes Business Park, Rockmill Road, Brockholes, Holmfirth HD9 7BN, United Kingdom Tel: +44 (0)1484 663388 • Fax: +44 (0)1484 666338 Website: www.burtonsafes.co.uk Quality System Cert. No. 1000 Assessed to ISO 9001:2008 Scope: Distribution, supply and commissioning of safes, safe locks, strong rooms and security cabinets.
Bush (Fire Engineering) Limited Unit 28 The Metro Centre, Kangley Bridge Road, Sydenham, London SE26 5BW, United Kingdom Tel: +44 (0)845 241 9860 • Fax: +44 (0)845 241 9861 E-mail: [email protected] Quality System Cert. No. 385 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems. Installation and servicing of dry risers.
CA Group Limited Evenwood Industrial Estate, Copeland Road, Evenwood, Co. Durham DL14 9SF, United Kingdom Tel: +44 (0)1388 834242 • Fax: +44(0)1388 834881 E-mail: [email protected] • Website: www.cagroup.ltd.uk Quality System Cert. No. 443 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of built-up roof and wall systems.
Cavicel SpA Via Caduti del Lavoro, 18/A, 20096 Pioltello, Milan, Italy Tel: +39 02 9216 0521 • Fax: +39 02 9216 0753 E-mail: [email protected] • Website: www.cavicel.com Quality System Cert. No. 217 Assessed to ISO 9001:2008 Scope: Design and manufacture of electric cables for installations that require safety in the event of fire.
Ceodeux - Firetec 24 Route de Diekirch - B.P.19, L-7505 Lintgen, Luxembourg Tel: +352 32 78 32-1 • Fax: +352 32 78 32-326 E-mail: [email protected] • Website: www.rotarex.com Quality System Cert. No. 724 Assessed to Factory Production Control to PN 111 Scope: Development, assembly, test and sale of BO480 differential pressure valves for fire suppression systems.
550
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Chaoyi Industry Development 3/F No. 4 Factory Building, Lang Kou Industrial Estate, Lang Kou Road, Lang Hau, Bao An District, Shenzhen, China Tel: +755 338 76556 • Fax: +755 338 76538 E-mail: [email protected] Quality System Cert. No. 876 Assessed to ISO 9001:2008 Scope: Manufacture of fire alarm bells.
Charter Sepcialist Security Limited Innovation House, Arkwright Road, Reading, Berkshire RG2 0LU, United Kingdom Tel: +44 (0) 845 0508705 • Fax: +44 (0) 845 0508707 E-mail: [email protected] • Website: www.chartergroupuk.com Quality System Cert. No. 1075 Assessed to ISO 9001:2008 Scope: Design, manufacture, fabrication, installation and repair of roller shutter systems.
Chemring Energetics Limited Ardeer Site, Stevenston, Ayrshire, Scotland KA20 3LN, United Kingdom Tel: +44 (0)1294 487007 • Fax: +44 (0)1294 487230 E-mail: [email protected] • Website: www.chemringenergetics.co.uk Quality System Cert. No. 313 Assessed to ISO 9001:2008 Scope: Manufacture of Metron actuators for installation in fire fighting systems.
Chubb Fire & Security Limited 400 Dallow Road, Luton, Beds LU1 1UR, United Kingdom Tel: +44 (0)1582 413694 • Fax: +44 (0)1582 456353 E-mail: [email protected] • Website: www.chubb.co.uk Quality System Cert. No. 315 Assessed to ISO 9001:2008 Scope: Installation, commissioning and servicing of fire detection and alarm systems.
Chubb Fire & Security Limited 5 Canal Place, Armley Road, Leeds LS12 2DU, United Kingdom Tel: +44 (0)113 235 5131 • Fax: +44 (0)113 235 5132 E-mail: [email protected] • Website: www.chubb.co.uk Quality System Cert. No. 309 Assessed to ISO 9001:2008 Scope: Installation, commissioning and servicing of fire detection and alarm systems.
20 Nov 2011
551
PART 6: SECTION 1 QUALITY SYSTEMS
Circum Limited Roundhouse Farm, Roestock Lane, Colney Heath, Hertfordshire AL4 0PP, United Kingdom Tel: +44 (0)1727 821228 • Fax: +44 (0)1727 822428 E-mail: [email protected] • Website: www.circum.ltd.uk Quality System Cert. No. 892 Assessed to ISO 9001:2008 Scope: Design, installation, service and maintenance of fire sprinkler systems, gas suppression systems and the sale of associated fire products.
Clark Door Limited Unit F Central, Kingmoor Park, Carlisle, Cumbria CA6 4SJ, United Kingdom Tel: +44 (0)1228 522321 • Fax: +44 (0)1228 401854 E-mail: [email protected] • Website: www.clarkdoor.com Quality System Cert. No. 106 Assessed to ISO 9001:2008 Scope: Manufacture and installation of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters.
CLD Fencing Systems Unit 11, Springvale Business Centre, Millbuck Way, Sandbach, Cheshire CW11 3HY, United Kingdom Tel: +44 (0)1270 764751 • Fax: +44 (0)1270 757503 E-mail: [email protected] • Website: www.cld-fencing.com Quality System Cert. No. 999 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of perimeter, security and sports fencing systems.
Clearway Environmental Services (UK) Limited 11 Landau Way, Darent Industrial Park, Erith, Kent DA8 2LF, United Kingdom Tel: +44 (0)1322 332211 • Fax: +44 (0)1322 339582 E-mail: [email protected] • Website: www.clearwayservices.co.uk Quality System Cert. No. 1001 Assessed to Factory Production Control to PN 111 Scope: Provision and installation of security doorsets for property protection.
Clymac Limited Cloudway Court, Belton Road, Loughborough LE11 1LW, United Kingdom Tel: +44 (0)1509 232651 • Fax: +44 (0)1509 232665 E-mail: [email protected] • Website: www.clymac.co.uk Quality System Cert. No. 687 Assessed to ISO 9001:2008 Scope: Design, supply, installation, commissioning and servicing of fire detection and alarm systems.
552
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Compco Fire Systems Limited Cleeve House, Malvern Road, Lower Wick, Worcester WR2 4YX, United Kingdom Tel: +44 (0)1905 741600 • Fax: +44 (0)1905 741620 E-mail: [email protected] Also at: High Banks House, Lawn Lane, Hemel Hempstead, Hertfordshire HP3 9HR, United Kingdom Tel: +44 (0)1442 242821
and 23 Fairfield Place, College Milton, East Kilbride G74 5LP, United Kingdom Tel: +44 (0)1355 570033 • Fax: +44 (0)1355 570044 E-mail: [email protected] Quality System Cert. No. 274 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler and foam systems, and hose reels.
Computionics Limited (Trading as C-Tec) Stephens Way, Goose Green, Wigan, Lancashire WN3 6PH, United Kingdom Tel: +44 (0)1942 322744/42444 • Fax: +44 (0)1942 829867 E-mail: [email protected] • Website: www.c-tec.co.uk Also at: Dark Lane, Mawdesley L40 2QU, United Kingdom Quality System Cert. No. 176 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire and security control and indicating equipment, associated alarm system components, and call equipment.
Control Equipment Limited Hillcrest Business Park, Dudley, West Midlands DY2 9AP, United Kingdom Tel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972 E-mail: [email protected] • Website: www.controlequipment.com Quality System Cert. No. 018 Assessed to ISO 9001:2008 Scope: Design and manufacture of detection and electronic control equipment for fire protection and other PCB assembly.
Cooper Fulleon Limited Llantarnam Park, Cwmbran, South Wales NP44 3AW, United Kingdom Tel: +44 (0)1633 628500 • Fax: +44 (0)1633 866346 E-mail: [email protected] • Website: www.cooperfulleon.com Quality System Cert. No. 378 Assessed to ISO 9001:2008 Scope: Design and manufacture of alarm sounders, beacons and manually activated signalling devices.
20 Nov 2011
553
PART 6: SECTION 1 QUALITY SYSTEMS
Cooper Lighting and Safety Limited Wheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United Kingdom Tel: +44 (0)1302 303303 • Fax: +44 (0)1302 367155 E-mail: [email protected] • Website: www.cooper-Is.com Quality System Cert. No. 714 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm panels.
Core Industrial Plastics Limited Unit 12, A1 Ferrybridge Business Park, Fishergate, Knottingley, West Yorkshire WF11 8NA, United Kingdom Tel: +44 (0)1977 676072 • Fax: +44 (0)1977 676069 E-mail: [email protected] Quality System Cert. No. 803 Assessed to ISO 9001:2008 Scope: Procurement and supply of printed FR board.
Corus Panels and Profiles Shotton Works, Flintshire CH5 2NH, United Kingdom Tel: +44 (0)1684 856600 • Fax: +44 (0)1684 856601 E-mail: [email protected] • Website: www.coruspanelsandprofiles.com Quality System Cert. No. 460 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of metal-faced profiles, roof and wall cladding, composite flooring, composite panels, façade systems, rain screen systems, structural tray systems including ancillary items and flashings in accordance with client’s specified requirements.
Cranford Controls Limited Unit 2, Waterbrook Estate, Waterbrook Road, Alton, Hampshire GU34 2UD, United Kingdom Tel: +44 (0)1420 592444 • Fax: +44 (0)1420 592445 E-mail: [email protected] • Website: www.cranfordcontrols.com Quality System Cert. No. 546 Assessed to ISO 9001:2008 Scope: Design, supply and manufacture of fire detection and alarm system accessories.
Crawford UK Limited 7 Churchill Way, 35A Business Park, Chapeltown, Sheffield, South Yorkshire S35 2PY, United Kingdom Tel: +44 (0)870 609 4474 • Fax: +44 (0)114 257 4397 E-mail: [email protected] • Website: www.crawfordsolutions.uk.com Quality System Cert. No. 001 Assessed to ISO 9001:2008 Scope: Supply, installation, maintenance and repair of industrial doors and loading bay equipment. Service Centres: Central & Southern UK: 7 Churchill Way, 35A Business Park, Chapeltown, Sheffield, South Yorkshire S35 2PY Tel: +44 (0)870 609 4474 Fax: +44 (0)114 257 4397
554
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS Email: [email protected] Website: www.crawfordsolutions.uk.com Northern UK: First Floor, Cedar House, Quarry Court, Livingston, West Lothian EH54 6AX Tel: +44 (0)1506 417237 Fax: +44 (0)1506 412726 Email: [email protected] Website: www.crawfordsolutions.uk.com Out of office hours: Tel.: +44 (0)1244 355235 New Product Sales & Installation: Contact Details: 7 Churchill Way, 35A Business Park, Chapeltown, Sheffield, South Yorkshire S35 2PY Tel: +44 (0)114 257 4330 Fax: +44 (0)114 257 4399 Certificate No. 001 Assessed to ISO 9001:2008 Scope: Supply and installation of industrial doors and loading bay equipment.
CTM Fire and Security Limited (Leyland & London Offices) Unit 2, Osprey Place, Moss Side Industrial Estate, Leyland PR26 7EW, United Kingdom Tel: +44 (0)800 5872753 • Fax: +44 (0)1772 641227 E-mail: [email protected] • Website: www.firealarmuk.com Including satellite office at: BBC Television Centre, Arch 118, Dodds Yard, Wood Lane, London W12 7RJ, United Kingdom Quality System Cert. No. 710 Assessed to ISO 9001:2008 Scope: Design, supply, installation, commissioning and servicing of fire detection and alarm systems. Installation, service of portable fire extinguishers.
Culimeta-Saveguard Limited Tame Valley Mill, Wainwright Street, Dukinfield, Cheshire SK16 5NB, United Kingdom Tel: +44 (0)161 344 2484 • Fax: +44 (0)161 344 2486 E-mail: [email protected] Quality System Cert. No. 552 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of cavity fore barriers and related fire protection products, protective textiles, thermal and accoustic insulation.
D.I.S. Sprinklers 183 Westgate Street, Gloucester GL1 2RN, United Kingdom Tel: +44 (0)1452 304927 • Fax: +44 (0)1452 306692 E-mail: [email protected] • Website: www.dis-ltd.co.uk Quality System Cert. No. 286 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
20 Nov 2011
555
PART 6: SECTION 1 QUALITY SYSTEMS
Daemon Fire and Security Limited Daemon House, 41-42 Albert Road, Tamworth, Staffs B79 7JS, United Kingdom Tel: +44 (0)1827 69266 • Fax: +44 (0)1827 53584 E-mail: [email protected] Quality System Cert. No. 542 Assessed to ISO 9001:2008 Scope: Installation, commissioning and servicing of fire detection and alarm systems.
Dalen Limited Valepits Road, Garretts Green Industrial Estate, Birmingham B33 0TD, United Kingdom Tel: +44 (0)121 783 3838 • Fax: +44 (0)121 784 6348 E-mail: [email protected] • Website: www.top-tec.co.uk Quality System Cert. No. 276 Assessed to ISO 9001:2008 Scope: Manufacture of physical security devices, computer and TV stands, materials handling and storage equipment, access platforms and general metal fabrication and powder coating services.
Datatag ID Limited 3000 Hillswood Drive, Hillswood Business Park, Chertsey, Surrey KT16 0RS, United Kingdom Tel: +44 (0)1932 895304 • Fax: +44 (0)1932 796797 E-mail: [email protected] • Website: www.datatag.co.uk 24/7 Telephone Number: 0845 0700 440 Quality System Cert. No. 665 Assessed to ISO 9001:2008 Scope: Design and distribution of asset identification systems and provision of secure database registration services.
Dätwyler Cables Unit of Dätwyler Switzerland Inc, Gotthardstrasse 31, CH-6460 Altdorf, Switzerland Tel: +41 41 875 1122 • Fax: +41 41 875 1860 E-mail: [email protected] • Website: www.daetwyler-cables.com Quality System Cert. No. 172 Assessed to ISO 9001:2008 Scope: Design and manufacture of electric cables for use in fire alarm installations.
Day-Impex Limited Station Works, Earls Colne, Colchester, Essex CO6 2ER, United Kingdom Tel: +44 (0)1787 223232 • Fax: +44 (0)1787 224171 E-mail: [email protected] • Website: www.day-impex.co.uk Quality System Cert. No. 291 Assessed to ISO 9001:2008 Scope: Manufacture of glass bulbs for fire sprinklers.
556
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Debro Engineering and Presswork trading as Unistrut Ltd Unit 2 Delta Point Trading Estate, Greets Green Road, West Bromwich, West Midlands B70 9PL, United Kingdom Tel: +44 (0)121 580 6350 • Fax: +44 (0)121 580 6364 Website: www.unistrut.co.uk Quality System Cert. No. 015 Assessed to ISO 9001:2008 Scope: Manufacture of brackets and pipe support equipment.
Defensor Group Limited Defensor House, 15 Kingsley Street, Leicester LE2 6DY, United Kingdom Tel: +44 (0)116 244 8689 • Fax: +44 (0)116 244 8884 E-mail: [email protected] Quality System Cert. No. 788 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning, service and maintenance of fire detection and alarm systems.
Delta Extinctors S. A. Birmingham Street 102, Brussels 1070, Belgium Tel: +32 (0) 2 528 08 70 • Fax: +32 (0) 2 521 07 31 E-mail: [email protected] • Website: www.delta.be Quality System Cert. No. 910 Assessed to Factory Production Control to PN 111 Scope: Manufacture of portable 1kg, 2kg & 3kg (BC & ABC powder) extinguishers in accordance with EN 3.
Design & Supply Limited 13 Pant Industrial Estate, Merthyr Tydfil, Mid Glamorgan CF48 2SR, United Kingdom Tel: +44 (0)1685 350114 • Fax: +44 (0)1685 723276 E-mail: [email protected] Quality System Cert. No. 694 Assessed to ISO 9001:2008 Scope: Design and manufacture of steel hinged door sets.
Dewey Waters Limited Heritage Works, Winterstoke Road, Weston-Super-Mare, Somerset BS24 9AN, United Kingdom Tel: +44 (0)1934 421477 • Fax: +44 (0)1934 421488 E-mail: [email protected] • Website: www.deweywaters.co.uk Quality System Cert. No. 135 Assessed to ISO 9001:2008 Scope: Manufacture and installation of GRP sectional and one-piece tanks, and industrial and commercial mouldings.
20 Nov 2011
557
PART 6: SECTION 1 QUALITY SYSTEMS
Digital Lighting (Dongguan) Co Ltd Xinmin Road, Xinmin District, Chang'an Town, Dongguan City, Guandong Province, China Tel: +86 769 5332372 • Fax: +86 769 5538520 E-mail: [email protected] • Website: www.dl-sv.com Quality System Cert. No. 685 Assessed to ISO 9001:2008 Scope: The design and manufacture of fire detection and alarm system components.
Doncaster Cables Millfields Industrial Estate, Arksey Lane, Bentley, Doncaster, South Yorkshire DN5 0SJ, United Kingdom Tel: +44 (0)1302 821700 • Fax: +44 (0)1302 821701 E-mail: [email protected] • Website: www.doncastercables.com Quality System Cert. No. 338 Assessed to ISO 9001:2008 Scope: Manufacture of electric cables for use in installations that require safety in the event of fire.
Dong-A Flexible Metal Tubes Co. Ltd. 4F Kowon Bldg. 20-19, Yangjae-Dong, Seocho-Gu, Seoul 137-888, Korea, Republic Of Tel: +82 (0)2 3476 2541 • Fax: +82 (0)2 3476 2540 E-mail: [email protected] Also at: #412-2 Chubook-Ri, Yangji-Myon, Yongin-Si, Gyeonggi-Do 449-822, Korea, Republic Of Quality System Cert. No. 565 Assessed to ISO 9001:2008 Scope: Design and manufacture of flexible hoses for sprinkler systems, flexible tubing for gas supplies and water supplies, uncoated or plastic coated.
DoorTechnik Moor Lane, Thorpe-on-the-Hill, Lincoln LN6 9BW, United Kingdom Tel: +44 (0)1522 693522 • Fax: +44 (0)1522 508494 Website: www.doortechnik.co.uk Quality System Cert. No. 1084 Assessed to ISO 9001:2008 Scope: Design, manufacture, installation and repair of fabricated products including general fabrication and metal based parts of a non-structural nature.
Draka UK Limited Alfreton Road, Derby DE21 4AE, United Kingdom Tel: +44 (0)1332 345431 • Fax: +44 (0)1332 331237 E-mail: [email protected] • Website: www.drakauk.com Quality System Cert. No. 361 Assessed to ISO 9001:2008 Scope: Manufacture of electric cables for use in installations that require safety in the event of fire.
558
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
DS SMITH CORREX (Trading as a division of DS Smith Plastics Limited) Madleaze Industrial Estate, Bristol Road, Gloucester GL1 5SG, United Kingdom Tel: +44 (0)1452 316500 • Fax: +44 (0)1452 300436 E-mail: [email protected] • Website: www.kaysersberg-plastics.com Quality System Cert. No. 227 Assessed to ISO 9001:2008 Scope: Design and development of plastics packaging and other products using thermoforming, injection moulding and structural foam, and conversion of structural sheet material. Manufacture of structural sheet and conversion into packaging and other products including flame retardant materials.
Dubai Cable Company (Private) Limited, Trading as Ducab Old Abu Dhabi Road, Jebel Ali, Dubai, United Arab Emirates Tel: +9714 808 2500 • Fax: +9714 808 2622 E-mail: [email protected] • Website: www.ducab.com, Sales office: PO Box 11529, Dubai, UAE Quality System Cert. No. 781 Assessed to Factory Production Control to PN 111 Scope: Manufacture of electric cables for installations that require safety in the event of fire.
Dubai Cable Company (Private) Limited, Trading as Ducab Ducab-M1, Plot No. - 2D12,3D2,4D2,5D2, Sector - M41, Industrial City of Abu Dhabi-1, Mussafah, Abu Dhabi, United Arab Emirates Tel: +9714 808 2500 • Fax: +9714 808 2622 E-mail: [email protected] • Website: www.ducab.com Quality System Cert. No. 782 Assessed to Factory Production Control to PN 111 Scope: Manufacture of electric cables for installations that require safety in the event of fire.
Dudley Safes Limited Unit 17 Deepdale Works, Deepdale Lane, Upper Gornal, Dudley, West Midlands DY3 2AF, United Kingdom Tel: +44 (0)1384 239991 • Fax: +44 (0)1384 455129 Website: www.dudleysafes.com Quality System Cert. No. 304 Assessed to ISO 9001:2008 Scope: Design and manufacture of free-standing safes.
Duplus Architectural Systems Limited 370 Melton Road, Leicester LE4 7SL, United Kingdom Tel: +44 (0)116 2610710 • Fax: +44(0)116 2610539 E-mail: [email protected] • Website: www.duplus.co.uk Quality System Cert. No. 1048 Assessed to Factory Production Control to PN 111 Scope: Fabrication and installation of aluminium windows, doors and curtain walling.
20 Nov 2011
559
PART 6: SECTION 1 QUALITY SYSTEMS
EMCOR Facilities Services Limited, EMCOR Specialist Services Premier House, Tollgate, Eastleigh, Hampshire SO53 3YE, United Kingdom Tel: +44 (0)2380 648028 • Fax: +44 (0)2380 648191 E-mail: [email protected] Quality System Cert. No. 620 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning, service and repair of fire detection and alarm systems.
Emirates Fire Fighting Equipment Factory L.L.C. (FIREX) P.O.Box 22436, Industrial Area 13, Sharjah, United Arab Emirates Tel: +971 6 5340300 • Fax: +971 6 5340090 E-mail: [email protected] • Website: www.firexuae.com Quality System Cert. No. 863 Assessed to ISO 9001:2008 Scope: Manufacture of fire cabinets, fire hose reels and wheeled unit fire extinguishers. Distribution of portable fire extinguishers and fire blankets. Design and installation of fire sprinkler systems, fire alarm systems and fire fighting systems. Distribution of landing valves and breech inlets. Design, manufacture and distribution of breech inlet cabinets. Manufacture of fire doors.
Envirowrap Solutions Limited Registered Office:, Strangford House, Church Road, Ashford, Kent TN23 3QR, United Kingdom Tel: +44 (0)1233 860080 • Fax: +44 (0)1233 860090 E-mail: [email protected] • Website: www.envirowrap.info Quality System Cert. No. 691 Assessed to ISO 9001:2008 Scope: Design, supply, distribution and installation of EnviroWrap flame retardant sheeting including the control of a sub contract manufacturing process.
Essex Safety Glass Limited Units 1-3, Moss Road, Witham, Essex CM8 3UG, United Kingdom Tel: +44 (0)1376 520061 • Fax: +44 (0)1376 521176 E-mail: [email protected] • Website: www.esguk.co.uk Quality System Cert. No. 997 Assessed to Factory Production Control to PN 111 Scope: Manufacture of security rated and bullet resistant glass.
560
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Eton Fire Limited Printers Gate, Limehouse Court, 3 - 11 Dod Street, London E14 7EQ, United Kingdom Tel: +44 (0)207 517 6300 • Fax: +44 (0)207 538 5231 E-mail: [email protected] • Website: www.etonfire.com Also at: Aynsley House, Waterside Business Centre, Wolverhampton Road, Cannock WS11 1SN, United Kingdom Tel: +44 (0)1543 431 340 • Fax: +44 (0)1543 571 680 E-mail: [email protected] • Website: www.etonfire.com Quality System Cert. No. 662 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Eurobond Laminates Limited & Eurobond Doors Limited Wentloog Corporate Park, Wentloog, Cardiff CF3 2ER, United Kingdom Tel: + 44 (0)2920 776677 • Fax: + 44 (0)2920 369161 E-mail: [email protected] • Website: www.eurobond.co.uk Eurobond Doors Limited Tel: +44 (0)29 20 36 11 11 • Fax: +44 (0)29 20 36 22 22 E-mail: [email protected]
Eurobond Laminates Limited Tel: +44 (0)2920 77 66 77 • Fax: +44 (0)2920 36 91 61 E-mail: [email protected] Quality System Cert. No. 545 Assessed to ISO 9001:2008 Scope: Certificates 523 (Eurobond Doors Limited) and 545 (Eurobond Laminates Limited) have been merged and the scope is as follows:Design, manufacture and supply of structural insulated panels, industrial doors, flashings and ancillaries.
Euroclad Limited Wentloog Corporate Park, Wentloog Road, Cardiff CF3 2ER, United Kingdom Tel: +44 (0)2920 790722 • Fax: +44 (0)2920 793149 E-mail: [email protected] • Website: www.euroclad.com Quality System Cert. No. 879 Assessed to Factory Production Control to PN 111 Scope: Manufacture of elite 1.25RW built-up roof and elite 55.30RW built-up wall rockfibre insulation plus elite 3.16GW built-up roof & elite 51.30 built-up wall with glass wool insulation to LPS 1181 Part 1: Issue 1.
20 Nov 2011
561
PART 6: SECTION 1 QUALITY SYSTEMS
Everday Technology Co. Limited No 8, Lane 492, Ba-Der Street, Shulin 238, Taipei Hsien, Taiwan ROC Tel: +886 2 2668 9668 • Fax: +886 2 2668 9666 E-mail: [email protected] • Website: www.everday.com Quality System Cert. No. 512 Assessed to ISO 9001:2008 Scope: Design and manufacture of smoke, heat, carbon monoxide, and gas detectors.
Excel Industries Ltd Maerdy Industrial Estate (South), Rhymney, Gwent NP22 5PY, United Kingdom Tel: +44 (0)1685 845200 • Fax: +44 (0)1685 844106 E-mail: [email protected] • Website: www.excelfibre.com Quality System Cert. No. 721 Assessed to Factory Production Control to PN 111 Scope: Manufacture of Warmcel Panel Systems.
Eyston Company Ltd 27 Zhen Tian South Road, Wei Xing Industrial Zone, Yan Tian, Feng Gang, Dongguan, Guangdong, China Tel: +852 25573135 • Fax: +852 28970249 E-mail: [email protected] • Website: www.eyston.com Quality System Cert. No. 679 Assessed to Factory Production Control to PN 111 Scope: Manufacture of smoke detectors.
F.V.S. Limited Broom Street, Off Huddersfield Road, Newhey, Rochdale OL16 3RY, United Kingdom Tel: +44 (0)1706 848599 • Fax: +44 (0)1706 843474 E-mail: [email protected] • Website: www.fvslimited.co.uk Quality System Cert. No. 151 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems. Fabrication of pipework for fire sprinkler systems.
Fendor Limited Heworth House, William Street, Felling, Gateshead NE10 0JP, United Kingdom Tel: +44 (0)191 438 3222 • Fax: +44 (0)191 438 1686 E-mail: [email protected] • Website: www.fendor.co.uk Quality System Cert. No. 712 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of specialist glazing systems.
562
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
FES Limited, FES Sprinklers Forth House, Pirnhall Business Park, Stirling FK7 8HW, United Kingdom Tel: +44 (0)1786 819600 • Fax: +44 (0)1786 811456 E-mail: [email protected] Quality System Cert. No. 853 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning and servicing of sprinklers systems.
FFE Fire & Security Limited 122 The Minories, London EC3 1NT, United Kingdom Tel: +44 (0)845 60 999 06 • Fax: +44 (0)20 8665 4125 E-mail: [email protected] • Website: www.ffe.co.uk Quality System Cert. No. 625 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning, repair and servicing of fire detection and alarm systems.
Fike Safety Technology Ltd Unit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United Kingdom Tel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656 E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk Quality System Cert. No. 331 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire alarm, detection and indicating equipment.
Filling and Packing Materials Manufacturing Company (F.I.P.C.O.) P.O. Box 8762, Riyadh 11492, Kingdom of Saudi Arabia Tel: +966 1265 2299 • Fax: +966 1265 1275 Quality System Cert. No. 871 Assessed to Factory Production Control to PN 111 Scope: Manufacture of woven coated polypropylene sheets (in rolls) to flame retardant standard LPS 1207.
Fire Alarm Solutions Limited Unit 2, Manor Way Business Centre, Fairview Industrial Park, Marsh Way, Rainham, Essex RM13 8UG, United Kingdom Tel: +44(0) 1708 521181 • Fax: +44(0) 1708 521182 E-mail: [email protected] • Website: www.fas-ltd.com Quality System Cert. No. 972 Assessed to ISO 9001:2008 Scope: Sprinkler system design and project management.
20 Nov 2011
563
PART 6: SECTION 1 QUALITY SYSTEMS
Fire Defence (Northern) Limited Unit 9, B.B.I.C. Innovation Way, Wilthorpe, Barnsley, South Yorkshire S75 1JL, United Kingdom Tel: +44 (0)1226 289558 • Fax: +44 (0)1226 249625 E-mail: [email protected] • Website: www.fire-defence.com Quality System Cert. No. 1053 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Fire Defence plc Crown Yealm House, Pathfields Business Park, South Molton EX36 3LH, United Kingdom Tel: +44 (0)1769 574070 • Fax: +44 (0)1769 574079 E-mail: [email protected] • Website: www.fire-defence.com Quality System Cert. No. 245 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Fire Logistics Limited Unit A4, Union Street, Shieldfield, Newcastle upon Tyne NE2 1AH, United Kingdom Tel: +44 (0)191 230 3647 • Fax: +44 (0)191 230 3650 E-mail: [email protected] • Website: www.firelogistics.co.uk Quality System Cert. No. 872 Assessed to ISO 9001:2008 Scope: Design, supply, installation and servicing of fire sprinkler systems.
Fire Protection Limited Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 231 E-mail: [email protected] • Website: www.fireprotection.co.uk Quality System Cert. No. 277 Assessed to ISO 9001:2008 Scope: Manufacture and installation of fire resistant ductwork systems and penetration seals.
Fire Queen Limited 23-37 Broadstone Road, Reddish, Stockport, Cheshire SK5 7AR, United Kingdom Tel: +44 (0)800 731 2748 • Fax: +44 (0)161 442 2664 E-mail: [email protected] • Website: www.firequeen.co.uk Quality System Cert. No. 489 Assessed to ISO 9001:2008 Scope: Supply, installation and servicing of portable fire extinguishers and fire hose reels. Supply and installation of fire safety notices.
564
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Fire Security (Sprinkler Installations) Limited Homefield Road, Haverhill, Suffolk CB9 8QP, United Kingdom Tel: +44 (0)1440 705815 • Fax: +44 (0)1440 704352 E-mail: [email protected] • Website: www.firesecurity.co.uk Quality System Cert. No. 144 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler and water spray systems. Fabrication of pipework for fire sprinkler systems.
Fireproof Fire Engineering Limited The Old Brewery, 40 Coldhurst Street, Oldham, Lancashire OL1 2BQ, United Kingdom Tel: +44 (0)161 620 0902 • Fax: +44 (0)161 620 0772 E-mail: [email protected] • Website: www.fireproofsprinklersystems.com Quality System Cert. No. 058 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler and water spray systems.
Firespray International Limited Flamebar House, South Road, Templefields, Harlow, Essex CM20 2AR, United Kingdom Tel: +44 (0)1279 634 230 • Fax: +44 (0)1279 634 232 E-mail: [email protected] • Website: www.firespray.eu.com Quality System Cert. No. 415 Assessed to ISO 9001:2008 Scope: Manufacture and installation of fire resistant ductwork systems and penetration seals.
Firetecnics Systems Limited 142 Vauxhall Street, London SE11 5RH, United Kingdom Tel: +44 (0) 20 7587 0927 • Fax: +44 (0) 20 7582 3496 E-mail: [email protected] • Website: www.firetecnics.com Quality System Cert. No. 555 Assessed to ISO 9001:2008 Scope: Installation, commissioning and servicing of fire detection and alarm systems.
First Fire Protection Limited Unit 3, Network 4, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3RF, United Kingdom Tel: +44 (0)1494 522031/2 • Fax: +44 (0)1494 452752 E-mail: [email protected] • Website: www.firstfireprotection.co.uk Quality System Cert. No. 158 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
20 Nov 2011
565
PART 6: SECTION 1 QUALITY SYSTEMS
Flameshield Products Limited (Incorporating Flameshield Limited) 4 The Limes, Ingatestone, Essex CM4 0BE, United Kingdom Tel: +44 (0)1277 352202 • Fax: +44 (0)1277 355419 E-mail: [email protected] • Website: www.flameshield.org Quality System Cert. No. 785 Assessed to ISO 9001:2008 Scope: The operation of licensed manufacturing agreement(s) to manufacture - Flameshield Products Ltd, fire resistant ductwork systems and the supervision of the licensees FPC management system(s). The operation of a licensed installer service to - inspect and certify Flameshield Products Ltd, fire resistant ductwork system(s) installations. The supply and installation of Flameshield Products Ltd - fire resistant ductwork systems.
Flexiform Business Furniture Limited-incorporating Asgard Secure Steel Storage 1392 Leeds Road, Bradford, West Yorkshire BD3 7AE, United Kingdom Tel: +44 (0)1274 706206 • Fax: +44 (0)1274 660867 E-mail: [email protected] • Website: www.flexiform.co.uk Quality System Cert. No. 596 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of business furniture and secure storage units.
Fortress Doors N.I. Limited 6 Trench Road, Hyde Park Industrial Estate, Newtownabbey, Belfast, Northern Ireland BT36 4TY, United Kingdom Tel: +44 (0)28 9034 2655 • Fax: +44 (0)28 9034 2651 E-mail: [email protected] • Website: www.fortaxa.com Quality System Cert. No. 1076 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of fire and security doors and roller shutters.
Franklin Hodge Industries Ltd. Jubilee Building, Faraday Road, Westfields Trading Estate, Hereford HR4 9NS, United Kingdom Tel: +44 (0)1432 269605 • Fax: +44 (0)1432 277454 E-mail: [email protected] • Website: www.franklinhodge.com Quality System Cert. No. 037 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of water storage tanks, tank refurbishment and maintenance.
Galglass Limited 321 Hough Lane, Wombwell, Barnsley, South Yorkshire S73 0LR, United Kingdom Tel: +44 (0)1226 340370 • Fax: +44 (0)1226 344200 E-mail: [email protected] • Website: www.galglass.com Quality System Cert. No. 108 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of cylindrical and rectangular water storage tanks.
566
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Gaocheng General Foundry Yucai Road, Gaocheng City, Hebei Province, China Tel: +86 311 8816 6123 • Fax: +86 311 8819 3601 E-mail: [email protected] Quality System Cert. No. 920 Assessed to ISO 9001:2008 Scope: Manufacture and machining of grey and ductile iron castings.
Globe Fire Sprinkler Corporation 4077 Air Park Drive, Standish, Michigan 48658, United States Tel: +1 989 846 4583 • Fax: +1 989 846 9231 Website: www.globesprinkler.com Quality System Cert. No. 147 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire sprinklers, fire protection valves, and related products for fire sprinkler systems.
Gloucester Composites Limited Fox House, Stonedale Road, Stonedale, Gloucestershire GL10 3SA, United Kingdom Tel: +44 (0)1453 791616 • Fax: +44 (0)1453 791516 E-mail: [email protected] • Website: www.gloucestercomposites.com Quality System Cert. No. 773 Assessed to ISO 9001:2008 Scope: Manufacture of sectional water tanks and a range of hot pressed SMC moulded products.
Godwin Pumps Limited Quenington, Cirencester, Gloucestershire GL7 5BX, United Kingdom Tel: +44 (0)1285 750271 • Fax: +44 (0)1285 750352 E-mail: [email protected] • Website: www.godwinpumps.co.uk Quality System Cert. No. 1027 Assessed to ISO 9001:2008 Scope: Design, manufacture, commissioning and service of centrifugal pumping equipment, system packages and fire pumps.
Goran Plastics Unit C, 5 Caxton Way, Watford Business Park, Watford, Herts WD18 8UA, United Kingdom Tel: +44 (0)1923 255700 • Fax: +44 (0)1923 255698 E-mail: [email protected] Quality System Cert. No. 688 Assessed to ISO 9001:2008 Scope: Manufacture of twinwall polypropylene sheeting.
20 Nov 2011
567
PART 6: SECTION 1 QUALITY SYSTEMS
Gordonson Fire Protection Limited Unit 8, Bombay Street, Bermondsey, London SE16 3UX, United Kingdom Tel: +44 (0)207 237 6707 • Fax: +44 (0)207 252 0152 E-mail: [email protected] Quality System Cert. No. 323 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Grange Door Systems Unit 12, Bilston Glen Industrial Estate, Edinburgh EH20 9LZ, United Kingdom Tel: +44 (0)131 440 7000 • Fax: +44 (0)131 440 7003 E-mail: [email protected] • Website: www.grangedoor.com Quality System Cert. No. 573 Assessed to ISO 9001:2008 Scope: Installation, servicing and repair of industrial doors, fire doors and fire rolling shutters.
Grundfos Fire Systems Ferryboat Lane, Castletown, Sunderland SR5 3JL, United Kingdom Tel: +44 (0)191 549 5555 • Fax: +44 (0)191 516 0067 Website: www.grundfos.co.uk Quality System Cert. No. 510 Assessed to ISO 9001:2008 Scope: Sales, manufacture and test of fire pumps and fire pump sets. Grundfos Europump Limited Oxford Court, Greenfold Way, Leigh, Lamcashire WN7 3XJ UK Scope: Installation, commissioning, service and repair of fire pumps and pump / sets.
gte Brandschutz AG Hamburger Straße 2, D-14532 Stahnsdorf, Germany Tel: +49 3329 6359-0 • Fax: +49 3329 6359-25 E-mail: [email protected] • Website: www.gte.ag Quality System Cert. No. 735 Assessed to ISO 9001:2008 Scope: Design, manufacture, installation, service and repair of gte conveyor shutters.
Gulf Security Technology Co. Ltd - A UTC Fire & Security Company No. 80 Changjiang East Road, Economic & Technological Development Zone, Qinhuangdao, Hebei Province 066004, China Tel: +86 0335 8502528 • Fax: +86 0335 8508942 E-mail: [email protected] • Website: www.gst.com.cn Quality System Cert. No. 548 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm systems and components.
568
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Guthrie Douglas Limited 12 Heathcote Way, Heathcote Industrial Estate, Warwick CV34 6TE, United Kingdom Tel: +44 (0)1926 452452 • Fax: +44 (0)1926 336417 E-mail: [email protected] • Website: www.guthriedouglas.com Quality System Cert. No. 193 Assessed to ISO 9001:2008 Scope: Design, manufacture and repair of drive and control systems for building automation including access and security systems, fire, smoke and solar protection equipment.
GW Sprinkler A/S Kastanievej 15, DK-5620 Glamsbjerg, Denmark Tel: +45 64 72 2055 • Fax: +45 64 72 2255 E-mail: [email protected] Quality System Cert. No. 084 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire sprinklers, fire protection valves and related products for fire sprinkler systems.
H S Jackson & Son (Fencing) Limited, t/a Jacksons Fencing Stowting Common, Ashford, Kent TN25 6BN, United Kingdom Tel: +44 (0)1233 750393 • Fax: +44 (0)1233 750178 E-mail: [email protected] • Website: www.jacksons-fencing.co.uk Quality System Cert. No. 913 Assessed to ISO 9001:2008 Scope: Design, manufacture, supply and installation of timber and steel, fencing, gate and security barriers to commercial, trade and domestic customers. The following location is included within the above scope of certification:Ashford Stowting Common, Ashford, Kent TN25 6BN Tel: +44 (0)1233 750393 Fax: +44 (0)1233 750178 Scope: Manufacture, supply and installation of timber and steel, fencing, gate and security barriers to commercial, trade and domestic customers. The following locations are included within the above scope of certification:Bath New Rock, Chilcompton, Radstock, Bath BA3 4GJ Tel: +44 (0)1761 232666 Fax: +44 (0)1761 232647 Chester Dragon Hall, Whitchurch Road, Chowley, Tattenhall, Chester CH3 9DU Tel: +44 (0)1829 770776 Fax: +44 (0)1829 770778
20 Nov 2011
569
PART 6: SECTION 1 QUALITY SYSTEMS
Haes Systems Limited Columbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, Middlesex UB8 2JP, United Kingdom Tel: +44 (0)1895 422066 • Fax: +44 (0)1895 420603 E-mail: [email protected] • Website: www.haes-systems.co.uk Quality System Cert. No. 810 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of fire detection and alarm system components.
Hall & Kay Fire Engineering (Manchester) 10 Westpoint, Clarence Avenue, Trafford Park, Manchester M17 1QS, United Kingdom Tel: +44 (0)161 872 7316 • Fax: +44 (0)161 872 7003 E-mail: [email protected] • Website: www.hkfire.co.uk Quality System Cert. No. 139 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Hall & Kay Fire Engineering (Paisley) Studio 3002, Abbey Mill, Seedhill Road, Paisley PA1 1TJ, United Kingdom Tel: +44 (0)141 887 4921 • Fax: +44 (0)141 887 6346 E-mail: [email protected] • Website: www.hkfire.co.uk Quality System Cert. No. 771 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Hall & Kay Fire Engineering (Thame) Thame Park Road, Thame, Oxfordshire OX9 3RT, United Kingdom Tel: +44(0) 1844 265008 • Fax: +44(0) 1844 265008 E-mail: [email protected] • Website: www.hkfire.co.uk Quality System Cert. No. 907 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning & servicing of fire detection, fire alarm and gaseous fire extinguishing systems.
Hall & Kay Fire Engineering (West Midlands) Sterling Park, Clapgate Lane, Woodgate Valley, West Midlands B32 3BU, United Kingdom Tel: +44 (0)121 421 3311 • Fax: +44 (0)121 422 7312 E-mail: [email protected] • Website: www.hkfire.co.uk Quality System Cert. No. 036 Assessed to ISO 9001:2008 Scope: Design, manufacture and servicing of fire sprinklers, alarm, dry and deluge valves and related products for fire sprinkler systems.
570
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Hall Fire Protection Limited Holloway Drive, Wardley Business Park, Worsley M28 2LA, United Kingdom Tel: +44 (0)161 793 4822 • Fax: +44 (0)161 794 4950 E-mail: [email protected] • Website: www.hallfire.co.uk Quality System Cert. No. 027 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler and water spray systems. Fabrication of pipework for fire sprinkler systems.
Hallmark Fire (a division of SFS Fire Services Ltd) Systems House, Stoke Road, Hoo, Rochester, Kent ME3 9NT, United Kingdom Tel: +44 (0)8700 111150 • Fax: +44 (0)8700 111160 E-mail: [email protected] • Website: www.hallmarkfire.co.uk Quality System Cert. No. 452 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning and servicing of fire detection systems, fire alarm systems and gaseous fire extinguishing systems.
Halton Foodservice Limited 11 Laker Road, Airport Industrial Estate, Rochester, Kent ME1 3QX, United Kingdom Tel: +44 (0)1634 666111 • Fax: +44 (0)1634 666333 E-mail: [email protected] • Website: www.halton.com/foodservice Quality System Cert. No. 996 Assessed to Factory Production Control to PN 111 Scope: Design and manufacture of KSA Filters.
Handan Boate Foundry Co Limited Foundry Industry Zone, Jize County, Handan, Hebei Province 057350, China Tel: +0310 766 2358 • Fax: +0310 766 2868 E-mail: [email protected] Quality System Cert. No. 921 Assessed to ISO 9001:2008 Scope: Manufacture and machining of grey and ductile iron castings.
Hart Door Systems Redburn Road, Westerhope Industrial Estate, Westerhope, Newcastle upon Tyne NE5 1PJ, United Kingdom Tel: +44 (0)191 214 0404 • Fax: +44 (0)191 271 1611 E-mail: [email protected] • Website: www.speedor.com Quality System Cert. No. 016 Assessed to ISO 9001:2008 Scope: Design, development, manufacture, installation, service and repair of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters.
20 Nov 2011
571
PART 6: SECTION 1 QUALITY SYSTEMS
Harvel Plastics Incorporated (Bakersfield) 7001 Schirra Court, Bakersfield, California 93313, United States Tel: +1 661 396 0653 • Fax: +1 661 396 1821 E-mail: [email protected] • Website: www.harvel.com Quality System Cert. No. 455 Assessed to ISO 9001:2008 Scope: Manufacture of PVC and CPVC pipes.
Harvel Plastics Incorporated (Easton) 300 Kuebler Road, Easton, Pennsylvania 18040, United States Tel: + 1 610 252 7355 • Fax: + 1 610 253 4436 E-mail: [email protected] Quality System Cert. No. 270 Assessed to ISO 9001:2008 Scope: Manufacture of PVC and CPVC pipe, shapes and ducts.
Hemsec Manufacturing Limited Stoney Lane, Rainhill, Prescot, Merseyside L35 9LL, United Kingdom Tel: +44 (0)151 426 7171 • Fax: +44 (0)151 493 1331 E-mail: [email protected] • Website: www.hemsec.com Quality System Cert. No. 558 Assessed to ISO 9001:2008 Scope: Manufacture of thermal insulating and fire resistant composite panels.
Henry Lewis and Sons (Wireworkers) Limited Unit 7, Bolling Road Industrial Estate, Bradford BD4 7HN, United Kingdom Tel: +44 (0) 1274 307359 • Fax: +44 (0) 1274 370784 E-mail: [email protected] • Website: www.henrylewisandson.co.uk Quality System Cert. No. 528 Assessed to ISO 9001:2008 Scope: Manufacture, assembly, installation and repair of physical security products, comprising retractable grilles, shutters, fencing and guards.
Heras U.K. Fencing Systems Herons Way, Balby, Doncaster DN4 8WA, United Kingdom Tel: +44 (0)1302 364551 • Fax: +44 (0)1302 322401 E-mail: [email protected] • Website: www.heras.co.uk Quality System Cert. No. 890 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of security fencing systems.
572
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Hersey Meters Highway 70, Cleveland (Rowan County), North Carolina 27013, United States Tel: +1 704 278 2221 • Fax: +1 704 278 9617 Website: www.herseymeters.com Quality System Cert. No. 481 Assessed to ISO 9001:2008 Scope: Manufacture of water meters and related waterworks products. Manufacture of butterfly valves and check valves.
Hershey Valve Co Limited No 16 Jing 2nd Road, Wuchi, Taichung 435, Taiwan ROC Tel: +886 4 2659 5377 • Fax: +886 4 2659 5288 Quality System Cert. No. 438 Assessed to ISO 9001:2008 Scope: Production of CPVC, UPVC and plastic pipes, fittings, valves, sheets and cable trays.
Hilti (Gt Britain) Limited 1 Trafford Wharf Road, Manchester M17 1BY, United Kingdom Tel: +44 (0)161 886 1000 • Fax: +44 (0)161 872 1240 Website: www.hilti.co.uk Freephone: 0800 886 100, Freefax: 0800 886 200 Quality System Cert. No. 090 Assessed to ISO 9001:2008 Scope: Stockholding and supply of fire penetration seals, sealants and fire rated foam filler.
Hochiki America Corporation 7051 Village Drive, Buena Park, California 90621, United States Tel: +1 714 522 2246 • Fax: +1 714 522 2268 E-mail: [email protected] • Website: www.hochiki.com Quality System Cert. No. 358 Assessed to ISO 9001:2008 Scope: Manufacture of fire detection and alarm system components. Procurement, distribution and repair of control indicating equipment for fire protection.
Hochiki Corporation 246 Tsuruma, Machidia, Tokyo 194-8577, Japan Tel: +81 3 3444 4111 • Fax: +81 3 3444 4167 E-mail: [email protected] • Website: www.hochiki.co.jp Also at: 141-1 Maehara, Ejiri, Kakuda, Miyagi 981-1521, Japan Quality System Cert. No. 117 Assessed to ISO 9001:2008 Scope: Machida:
20 Nov 2011
573
PART 6: SECTION 1 QUALITY SYSTEMS Design of fire and gas leakage alarms. Design and manufacture of fire detectors and fire control and indicating equipment. Design and manufacture control panels for road tunnels. Design and manufacture control panels for fire sprinkler systems. Control of outsourcing manufacture for emergency alarm equipment and alarm sounders. Design and manufacture of small power radio equipment. Scope: Miyagi Manufacture of point type smoke and heat detectors, optical beam smoke detectors and fire and gas leakage alarms. Control of outsourcing manufacture for emergency alarm equipment. Manufacture of small power radio equipment.
Hochiki Europe (UK) Limited Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132 E-mail: [email protected] Quality System Cert. No. 164 Assessed to ISO 9001:2008 Scope: Design, manufacture, service and maintenance of fire detection and alarm equipment.
Honeywell Life Safety Systems UK 140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United Kingdom Tel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300 E-mail: [email protected] • Website: www.gent.co.uk Quality System Cert. No. 042 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm systems and components.
Honeywell Security UK Limited Newhouse Industrial Estate, Fire Exit 3, Motherwell, Lanarkshire ML1 5SB, United Kingdom Tel: +44 (0)1698 738200 • Fax: +44 (0)1698 738300 E-mail: [email protected] • Website: www.honeywell-security.co.uk Repair at: Aston Fields Road, Whitehouse Industrial Estate, Runcorn, Cheshire WA7 3DL, United Kingdom Quality System Cert. No. 787 Assessed to ISO 9001:2008 Scope: Design, repair and sales of intruder security products.
Horing LIH Industrial Co Ltd No. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROC Tel: +886 2 22487599 • Fax: +886 2 22407752 Quality System Cert. No. 506 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm components.
574
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Hosiden Besson Limited St Joseph's Close Trading Estate, St Joseph's Close, Hove, East Sussex BN3 7EZ, United Kingdom Tel: +44 (0)1273 860000 • Fax: +44 (0)1273 777501 E-mail: [email protected] • Website: www.hbl.co.uk Quality System Cert. No. 539 Assessed to ISO 9001:2008 Scope: Design and supply of audible alarm devices.
Huzhou Jiusheng Electric Co Ltd 1000 Xifeng Road, Huzhou Economy & Technology Zone, Huzhou, Zhejiang Province 313000, China Tel: +86 572 222 8188 • Fax: + 86 572 222 8177 E-mail: [email protected] Quality System Cert. No. 948 Assessed to Factory Production Control to PN 111 Scope: The manufacture and supply of mineral insulated cables not exceeding 500V.
Iceberg Building Services Limited 1 Station Court, Station Approach, Wickford, Essex SS11 7AT, United Kingdom Tel: +44 (0)1268 739450 • Fax: +44 (0)1268 739439 E-mail: [email protected] • Website: www.iceberybuildingservices.co.uk Quality System Cert. No. 934 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning and servicing of fire detection and alarm systems. Design, installation and maintenance of air conditioning and ventilation systems.
Icopal S. A. Parc Industriel des Hauts Sarts, Rue de Hermee 186, Herstal, Belgium Tel: +32 4240 5151 • Fax: +32 4240 5199 E-mail: [email protected] • Website: www.decra.co.uk Quality System Cert. No. 834 Assessed to Factory Production Control to PN 111 Scope: Manufacture and supply of metal roof and cladding systems including accessories.
Industrial Door Engineering Limited Winnington Avenue, Winnington, Northwich, Cheshire CW8 4EQ, United Kingdom Tel: +44 (0)1606 871832 • Fax: +44 (0)1606 871482 E-mail: [email protected] • Website: www.industrial-door-eng.co.uk Quality System Cert. No. 165 Assessed to ISO 9001:2008 Scope: Design, manufacture, installation and servicing of fire rolling shutters and industrial rolling shutters. Installation and servicing of fire doors and industrial doors.
20 Nov 2011
575
PART 6: SECTION 1 QUALITY SYSTEMS
Influx Measurements Limited 1A Bennett House, The Dean, Alresford, Hampshire SO24 9BQ, United Kingdom Tel: +44 (0)1962 736736 • Fax: +44 (0)1962 736737 E-mail: [email protected] Quality System Cert. No. 464 Assessed to ISO 9001:2008 Scope: Design and manufacture of direct reading flow meters.
IPB N.V. Steenovenstraat 30, B-8790 Waregem, Belgium Tel: +32 56 60 79 19 • Fax: +32 56 61 08 85 Quality System Cert. No. 365 Assessed to ISO 9001:2008 Scope: Design, development, manufacture and sales of plastic sheets.
Irish Driver-Harris Company Limited Millbanks, New Ross, Co Wexford, Ireland Tel: +353 51 421 405 • Fax: +353 51 422 983 E-mail: [email protected] Quality System Cert. No. 408 Assessed to ISO 9001:2008 Scope: Manufacture of electric cables for use in installations that require safety in the event of fire.
Irish Industrial Tanks Limited Unit C1, Ballymount Drive Industrial Estate, Ballymount Road, Walkinstown, Dublin 12, Ireland Tel: +353 1 450 7893 • Fax: +353 1 450 6404 E-mail: [email protected] • Website: www.iit.ie Quality System Cert. No. 112 Assessed to ISO 9001:2008 Scope: Supply and installation of water storage tanks.
Irish Sprinkler & Fire Protection Limited Damastown Green, Damastown Industrial Estate, Mulhuddart, Dublin 15, Ireland Tel: +353 1 8614036 • Fax: +353 1 8614037 E-mail: [email protected] • Website: www.joneseng.com Quality System Cert. No. 382 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
576
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Isoclad Limited 10 Alder Road, West Chirton North Industrial Estate, North Shields, Tyne & Wear NE29 8SD, United Kingdom Tel: +44 (0)191 258 5052 • Fax: +44 (0)191 259 5742 E-mail: [email protected] • Website: www.isoclad.co.uk Quality System Cert. No. 142 Assessed to ISO 9001:2008 Scope: Manufacture of fire resistant and industrial wall and ceiling cladding materials. Manufacture of fire resistant and industrial cold storage wall panels. Manufacture of polyisocyanurate foam (PIR) products.
J & J Design Limited Unit 4, Underbank Way, Carrs Industrial Estate, Haslingden, Rossendale, Lancashire BB4 5HR, United Kingdom Tel: +44 (0)1706 223414 • Fax: +44 (0)1706 225639 E-mail: [email protected] • Website: www.jjsprinklers.co.uk Quality System Cert. No. 299 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
J Durrance & Co Ltd Durrance House, 855 London Road, West Thurrock, Essex RM20 3LG, United Kingdom Tel: +44 (0)1708 258999 • Fax: +44 (0)1708 258900 E-mail: [email protected] • Website: www.jdurrance.co.uk Quality System Cert. No. 588 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of pedestrian access security, fire doors and anti bandit screens. Installation and servicing of roller shutter and fire doors. Also at: Unit 3, Hanlon Court, Royal Industrial Estate, Jarrow, Newcastle-upon-Tyne NE32 2HR UK Tel: +44 (0)191 428 6000 Fax: +44 (0)191 483 8787 Quality System Cert. No. 588 Assessed to ISO 9001:2008 Scope: Manufacture, installation, service and repair of door, grilles, rolling shutters, fire doors and fire roller shutters.
J. Bryceland Fire Systems Ltd Nobel Road, West Gourdie Industrial Estate, Dundee DD2 4XE, United Kingdom Tel: +44 (0)1382 624000 • Fax: +44 (0)1382 624300 E-mail: [email protected] • Website: www.jbrycelandfiresystems.co.uk Quality System Cert. No. 960 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of automatic sprinkler systems. Installation of wet and dry hydrant risers and hose reels.
20 Nov 2011
577
PART 6: SECTION 1 QUALITY SYSTEMS
K.P.F.P. Limited 59 Pound Street, Carshalton, Surrey SM5 3PG, United Kingdom Tel: +44 (0)20 8544 4844 • Fax: +44 (0)20 8544 4819 E-mail: [email protected] • Website: kpfp.co.uk Quality System Cert. No. 725 Assessed to ISO 9001:2008 Scope: Design, supply, installation, testing and repair of sprinkler systems, hose reels, hydrants and risers.
KAC Alarm Company Limited KAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United Kingdom Tel: +44 (0)1527 406655 • Fax: +44 (0)1527 406677 E-mail: [email protected] OR [email protected] • Website: www.kac.co.uk Quality System Cert. No. 166 Assessed to ISO 9001:2008 Scope: Design and manufacture of manual call points, sounders and sounder strobes.
Kean Building & Fire Protection Services Limited 39/43 Temple Bar, Willenhall, West Midlands WV13 1SH, United Kingdom Tel: +44 (0)1902 603550 • Fax: +44 (0)1902 608017 E-mail: [email protected] Quality System Cert. No. 411 Assessed to ISO 9001:2008 Scope: Design and installation of fire sprinkler systems.
Kentallen Fire Protection Limited Lancaster Road, Lowmoss Industrial Estate, Bishopbriggs, Glasgow G64 2LL, United Kingdom Tel: +44 (0)141 762 2540 • Fax: +44 (0)141 762 0823 E-mail: [email protected] Quality System Cert. No. 395 Assessed to ISO 9001:2008 Scope: Design and installation of fire sprinkler systems.
Kentec Electronics Limited Units 25-27, Fawkes Avenue, Questor, Dartford, Kent DA1 1JQ, United Kingdom Tel: +44 (0)1322 222121 • Fax: +44 (0)1322 291794 E-mail: [email protected] • Website: www.kentec.co.uk Quality System Cert. No. 360 Assessed to ISO 9001:2008 Scope: Design, manufacture, sales and servicing of control panels for fire detection, extinguishing release, sprinkler systems, water and smoke detection, associated power supplies, battery chargers and supply of printed circuit assemblies including metal fabrication, powder coating and silk screening of enclosures.
578
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Keystone Electric Wire & Cable Company Limited #110 D.D. 83, Kwan Ti North Village, Fanling, New Territories, Hong Kong Tel: +852 2691 7183 • Fax: +852 2695 9738 E-mail: [email protected] • Website: www.keystonecable.com Quality System Cert. No. 663 Assessed to ISO 9001:2008 Scope: Sales: Design and supply of electric wires and cables for use in installations which require safety in the event of fire. Dongguan Factory: Dongguan Keystone Electric Wire & Cable Company Ltd Ye Sha Management District, Shatin, Dongguan City, Guangdong, People's Republic of China Scope: Design, manufacture and supply of electric wires and cables up to 35KV for use in installations which require safety in the event of fire.
Kidde Products Ltd, trading as AirSense Technology Unit 1, Caxton Place, Caxton Way, Stevenage, Hertfordshire SG1 2UG, United Kingdom Tel: +44 (0)1462 751296 • Fax: +44 (0)1462 729137 E-mail: [email protected] • Website: www.airsense.co.uk/airsense Quality System Cert. No. 404 Assessed to ISO 9001:2008 Scope: Design and manufacture of aspirating smoke detectors and supply of aspirating pipe, associated fittings and accessories.
Kingfell Plc Capital Tower, 12th Floor, 91 Waterloo Road, London SE1 8RT, United Kingdom Tel: +44 (0)845 60 61 999 • Fax: +44 (0)845 25 81 999 E-mail: [email protected] • Website: www.kingfell.com Quality System Cert. No. 475 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning and servicing of fire detection and alarm systems.
Kingspan Door Components S.A. Zone Industrielle De L'Europe 1A, 7900 Leuze-En-Hainaut, Belgium Tel: +32 (0)69 868222 Website: www.kingspandoor.com Quality System Cert. No. 1063 Assessed to ISO 9001:2008 Scope: The design, manufacture and distribution of PUR/PIR foam filled composite door panels and components.
20 Nov 2011
579
PART 6: SECTION 1 QUALITY SYSTEMS
Kingspan Insulation Limited Pembridge, Leominster, Herefordshire HR6 9LA, United Kingdom Tel: +44 (0)1544 388601 • Fax: +44 (0)1544 388888 E-mail: [email protected] • Website: www.insulation.kingspan.com Also at: Sherburn Enterprise Park, Enterprise Way, Sherburn-in-Elmet, North Yorkshire LS25 6NA, United Kingdom Quality System Cert. No. 388 Assessed to ISO 9001:2008 Scope: Leomister: Design and manufacture of insulated and fire rated flat and tapered rigid polyurethane, polyisocyanurate and phenolic thermal insulation boards. Design, manufacture and sales of pre-mitred tapered roof systems. Scope: Sherburn-in Elmet: Manufacture of insulated products.
Kingspan Ltd Carrickmacross Road, Kingscourt, Co. Cavan, Ireland Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77 E-mail: [email protected] • Website: www.kingspanpanels.com Quality System Cert. No. 186 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire resistant wall and roof cladding materials and industrial wall and roof cladding materials, multi-beam purlins and accessories, gutters, flashing systems and single and double translucent roof lights.
Kingspan Ltd trading as Kingspan Structural, Kingspan Fabrications, Kingspan Controlled Environments (KCE), Kingspan Profiles and Sections Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom Tel: +44 (0)1944 710591 • Fax: +44 (0)1944 710777 E-mail: [email protected] • Website: www.wards.co.uk Quality System Cert. No. 279 Assessed to ISO 9001:2008 Scope: Design and manufacture of foam filled fire resistant insulated panels for roof, wall and cold store applications and ancillaries, cold rolled Multi-Beam, rail and channel sections, floor deck profiles; flashings, building ancillaries and architectural façade systems. Design, manufacture and installation of Kingframe building systems and cold rolled steel sections. Pre-treatment and protective coating to steel and galvanized components for architecturtal and industrial applications.
Kingspan Ltd. Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161 E-mail: [email protected] • Website: www.kingspanpanels.com Quality System Cert. No. 260 Assessed to ISO 9001:2008 Scope: Manufacture of fire resistant and industrial wall and roof cladding materials.
580
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
KingspanTarec Industrial Insulation Limited Glossop Brook Road, Glossop, Derbyshire SK13 8GF, United Kingdom Tel: +44 (0)870 733 0021 • Fax: +44 (0)870 700 0022 E-mail: [email protected] • Website: www.kingspantarec.co.uk Quality System Cert. No. 035-2 Assessed to ISO 9001:2008 Scope: Manufacture of polyurethane and phenolic rigid foam insulation.
KME Italy SpA Via Della Repubblica 257, 55051 Fornaci Di Barga, Lucca, Italy Tel: +39 0583 701.1 • Fax: +39 0583 701623 E-mail: [email protected] • Website: www.kme-italy.com Quality System Cert. No. 427 Assessed to ISO 9001:2008 Scope: Manufacture of mineral insulated cables for use in installations that require safety in the event of fire.
L.B.S. Group (incorporating L.B.S Security Services Limited - t/a Specialized Door Services, Russell Shutters, Olsen Shutters and Ranford Doors) Unit 6, Sterling Trading Estate, Rainham Road South, Dagenham, Essex RM10 8TX, United Kingdom Tel: +44 (0)208 526 8572 • Fax: +44 (0)208 984 0378 Quality System Cert. No. 247 Assessed to ISO 9001:2008 Scope: Manufacture, installation and servicing of industrial doors, industrial rolling shutters and fire rolling shutters.
Liddle Doors Limited Wagonway Road Industrial Estate, Hebburn, Tyne and Wear NE31 1SP, United Kingdom Tel: +44 (0)191 483 5449 • Fax: +44 (0)191 489 0698 E-mail: [email protected] • Website: www.liddledoors.co.uk Quality System Cert. No. 442 Assessed to ISO 9001:2008 Scope: Manufacture and installation of specialist steel security doors, screens and glazed steel entrance systems.
Lincs Doors Limited Innovation Way, Europarc, Grimsby, North East Lincolnshire DN37 9TT, United Kingdom Tel: +44 (0)1472 311057 • Fax: +44 (0)1472 311058 E-mail: [email protected] • Website: www.lincsdoors.co.uk Quality System Cert. No. 777 Assessed to ISO 9001:2008 Scope: Manufacture, supply and installation of industrial and fire doors.
20 Nov 2011
581
PART 6: SECTION 1 QUALITY SYSTEMS
Lingjack Engineering Works PTE Ltd No. 1 Woodlands Terrace, #03-01 Lingjack Industrial Building 738471, Singapore Tel: +65 6759 4163 • Fax: +65 6758 7513 E-mail: [email protected] • Website: www.combat.com.sg Quality System Cert. No. 501 Assessed to ISO 9001:2008 Scope: Manufacture of portable fire extinguishers, fire hose reels, breeching inlets, dry risers, high pressure landing valves and fire fighting hose assemblies. Non-ferrous casting, machining and testing process.* (*Foundry Address: 35, Jalan Canggih 8, Taman Perindustrian Cemerling, 81800 Ulu Tiram, Johor, Malaysia)
Linkester Fire Protection Limited 4/6 Cross Street, Macclesfield, Cheshire SK11 7PG, United Kingdom Tel: +44 (0)1625 511272 • Fax: +44 (0)1625 511272 E-mail: [email protected] Quality System Cert. No. 086 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler and foam systems.
Lion Steelworks SDN. BHD. Lot 4, Solok Waja 3, Kawasan Perindustrian Bukit Raja, 41050 Klang, Selangor, Malaysia Tel: +603 3341 3822 • Fax: +603 3342 7630 E-mail: [email protected] Quality System Cert. No. 639 Assessed to Factory Production Control to PN 111 Scope: Design and manufacture of safes, strong rooms and secure cabinets.
Lixil Nittan Company Limited 1-11-6, Hatagaya, Shibuya-Ku, Tokyo 151-8535, Japan Tel: +81 3 3468 1116 • Fax: +81 3 3468 1120 Quality System Cert. No. 756 Assessed to ISO 9001:2008 Scope: Design, development of automatic fire detectors, fire alarm control systems, indicating equipment and fire extinguishing equipment including management of distribution centres.
Lixil Nittan Electronic Company Limited 1 Higashi-Kibogaoka, Asahi-ku, Yokohama, Kanagawa 241-0826, Japan Tel: +81 45 364 4751 • Fax: +81 45 363 2678 Quality System Cert. No. 755 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire alarm control equipment. Also at: 563-6, 1-Chome, Toyonodai, Otonemachi, Kitasaitama-gun, Saitama, Japan 1, Aza Minamihata, Kohnoike, Itami, Hyougo 664-0006, Japan
582
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Scope at above addresses: Manufacture of automatic fire detectors.
Lowrey Contractors Limited 200 South Liberty Lane, Ashton Vale Trading Estate, Ashton Vale, Bristol BS3 2TW, United Kingdom Tel: +44 (0)117 9637111 • Fax: +44 (0)117 9637111 E-mail: [email protected] • Website: www.lowrey-contractors.co.uk Quality System Cert. No. 974 Assessed to ISO 9001:2008 Scope: Supply and installation of modular security kiosks and cages, perimeter and power fencing, gates, barriers, window barsets and alarm ducting.
LPG Tecnicas en Extincion de Incendios, S.L. Mestre Joan Corrales 107-109, 08950 Esplugues de Llobregat, Barcelona, Spain Tel: +34 93 480 2925 • Fax: +34 93 473 7492 E-mail: [email protected] • Website: www.lpg.es Also at: Sierra de Guadarrama, 32 Naves A y B, Poligono Industrial San Fernando 1, 28830 San Fernando De Henares, Madrid, Spain
and C/ Josep Ros i Ros no. 19A y 19B, Poligono Industrial la Clota, 08740 Sant Andreu de la Barca, Barcelona, Spain
and Pol. Ind. La Canaleta, Parcela no. 6 Naves 1 y 2, 25300 Tarrega, Lleida, Spain Quality System Cert. No. 446 Assessed to ISO 9001:2008 Scope: The design and manufacture of gaseous fire suppression components and the periodical maintenance, inspection, test and refilling of gas cylinders.
Lubrizol Advanced Materials Europe B.V.B.A Nijverheidsstraat 30, B-2260 Westerlo, Oevel, Belgium Tel: +32 14 24 16 11 • Fax: +32 14 24 18 19 Quality System Cert. No. 535 Assessed to ISO 9001:2008 Scope: Manufacture, quality control and distribution of Temprite CPVC products.
20 Nov 2011
583
PART 6: SECTION 1 QUALITY SYSTEMS
M & P Fire Solutions Ltd Suite 17, The Cubes Offices, Beacon South Quarter, Sandyford, Dublin 18, Ireland Tel: +353 1 293 3846/47/48/49 • Fax: +353 1 293 7951 E-mail: [email protected] Quality System Cert. No. 795 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
M. J. Quinn Integrated Services Limited Oak House, Overbrook Lane, Knowsley Business Park, Knowsley, Merseyside L34 9FB, United Kingdom Tel: +44 (0)151 547 8800 • Fax: +44 (0)151 547 8801 E-mail: [email protected] • Website: www.mjquinn.co.uk Quality System Cert. No. 492 Assessed to ISO 9001:2008 Scope: Installation, commissioning and servicing of fire detection and alarm systems.
M. J. Quinn Integrated Services Limited 5th Floor, 119 Farringdon Road, London EC1R 3DA, United Kingdom Tel: +44 (0)207 239 8750 • Fax: +44 (0)207 239 8751 E-mail: [email protected] • Website: www.mjquinn.co.uk Quality System Cert. No. 529 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning and servicing of fire detection, alarm systems and sprinkler systems.
Mavili Elektronik Ticaret Ve Sanayi A.S. Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, Turkey Tel: +90 216 4664 505 • Fax: +90 216 4664 510 E-mail: [email protected] • Website: www.mavigard.com Quality System Cert. No. 926 Assessed to ISO 9001:2008 Scope: Design, manufacture, sale & after sale services of fire & gas detectors, control panels & accessories.
McAvoy Group Limited 2 Ferguson Road, Knockmore Hill Industrial Estate, Lisburn, Co Antrim BT28 2FW, United Kingdom Tel: +44 (0)870 2408987 • Fax: +44 (0)28 8774 88495 E-mail: [email protected] • Website: www.mcavoygroup.com Quality System Cert. No. 728 Assessed to ISO 9001:2008 Scope: Design, manufacture and fabrication of portable modular buildings.
584
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
MECE Fire & Security Limited Courtlodge, Kemsley Street Road, Bredhurst, Gillingham, Kent ME7 3LS, United Kingdom Tel: +44 (0)1634 260607 • Fax: +44 (0)1634 260278 E-mail: [email protected] • Website: www.mecefireandsecurity.co.uk Quality System Cert. No. 733 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire alarm, security, access control and CCTV systems.
Mercian Shutters Limited Pearsall Drive, Brades Road Industrial Estate, Oldbury, West Midlands B69 2RA, United Kingdom Tel: +44 (0)121 544 6124 • Fax: +44 (0)121 552 6793 E-mail: [email protected] • Website: www.merciandoors.co.uk Quality System Cert. No. 355 Assessed to ISO 9001:2008 Scope: Design, manufacture, installation, servicing and repair of industrial doors, industrial rolling shutters, fire doors and fire rolling shutters. Mercian Industrial Doors (Southern) Limited t/a Mercian Industrial Doors Southern, 10-12 Galleymead Road, Colnbrook, Slough, Berkshire SL3 0EN UK Tel: +44 (0)1753 681 020 Fax: +44 (0)1753 684 842 Scope: Installation, servicing and repair of industrial doors, industrial rolling shutters, fire doors, fire rolling shutters and collapsible gates. Manufacture of collapsible gates.
Mercury Engineering Mercury House, Sandyford Industrial Estate, Foxrock, Dublin 18, Ireland Tel: +353 1 216 3000 • Fax: +353 1 216 3006 E-mail: [email protected] • Website: www.mercury.ie Quality System Cert. No. 231 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Midas Technologies (GB) Limited Unit A, Roundhouse Close, Eastern Industry, Peterborough PE1 5TA, United Kingdom Tel: +44 (0)1733 342600 • Fax: +44 (0)1733 346672 E-mail: [email protected] • Website: www.midastech.co.uk Quality System Cert. No. 421 Assessed to ISO 9001:2008 Scope: Manufacture of access covers and general metal fabrication.
Midland Door Services Limited Booth Street, Smethwick, West Midlands B66 2PF, United Kingdom Tel: +44 (0)121 565 0022 • Fax: +44 (0)121 565 0055 E-mail: [email protected] • Website: www.mdsind.co.uk Quality System Cert. No. 964 Assessed to ISO 9001:2008 Scope:
20 Nov 2011
585
PART 6: SECTION 1 QUALITY SYSTEMS Manufacture, installation, service and repair of all types of door systems.
MITIE McCartney Fire Protection Limited Meiklewood Gate, 35 Meiklewood Road, Glasgow G51 4GB, United Kingdom Tel: +44 (0)141 880 2700 • Fax: +44 (0)141 880 2701 E-mail: [email protected] • Website: www.mitie.co.uk Also included within the scope of certification Unit 11, Hobbs Cross Business Centre, Hobbs Cross Road, Theydon Garnon, Essex CM16 7NY, United Kingdom Tel: +44 (0)1992 813 598 • Fax: +44 (0)1992 814 541
and Units 16 & 18, Whitwick Business Centre, Stenson Road, Coalville, Leicestershire LE67 4JP, United Kingdom Tel: +44(0)1530 276 166 • Fax: +44(0)1530 276 167 Quality System Cert. No. 769 Assessed to ISO 9001:2008 Scope: Design, specification, installation, inspection, servicing and repair of all types of passive fire protection and performance coating systems.
MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems) Ventura House, Ventura Park Road, Tamworth B78 3HL, United Kingdom Tel: +44 (0)1827 303251 • Fax: +44 (0)1827 309798 Website: www.mitie.com Quality System Cert. No. 776 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning and servicing of fire detection and alarm systems.
Mitsubishi Plastics Inc Hiratsuka Factory, 2-1-35 Nishishindo, Hiratsuka City, Kanagawa Prefecture 254-8614, Japan Tel: +81 4 6322 8065 • Fax: +81 4 6355 9450 E-mail: [email protected] • Website: www.mpi.co.jp Sales Enquiries: 1-2-2, Nihonbashi Hongokucho, Chuo-ku, Tokyo 103-0021, Japan Tel: +81 3 3279 3455 • Fax: +81 3 3279 6740 E-mail: [email protected] • Website: www.mpi.co.jp Quality System Cert. No. 447 Assessed to ISO 9001:2008 Scope: Design and manufacture of hot press moulded GRP sectional water storage tanks.
586
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Modgal Metal (99) Limited Rosh Pina Industrial Park, Rosh Pina 12000, Israel Tel: +972 4 691 4222 • Fax: +972 4 691 4202 E-mail: [email protected] • Website: www.modgalmetal.com Quality System Cert. No. 123 Assessed to ISO 9001 Scope: Manufacture of pipe couplings, fittings and general purpose malleable, ductile and grey iron castings.
Monarflex Lyskaer 10,, DK-2730 Herlev, Copenhagen, Denmark Tel: +45 44 88 55 50 • Fax: +45 44 88 55 99 E-mail: [email protected] • Website: www.special-fire.com Quality System Cert. No. 540 Assessed to ISO 9001 Scope: Manufacture and supply of reinforced plastic sheeting and special membranes, including related products.
Morgan Marine Limited Llandybie, Ammanford, Carmarthenshire SA18 3GY, United Kingdom Tel: +44 (0)1269 850437 • Fax: +44 (0)1269 850656 E-mail: [email protected] • Website: www.morgan-marine.com Quality System Cert. No. 1051 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of industrial housing, covers and tanks including RF and NEMP screened enclosures and sound proof housings in composite materials including plastic, alloys and timber.
Morley-IAS Fire Systems By Honeywell Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888 E-mail: [email protected] • Website: www.morley-ias.co.uk Quality System Cert. No. 429 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm systems.
20 Nov 2011
587
PART 6: SECTION 1 QUALITY SYSTEMS
N.V. Joris IDE Hille 174, B-8750, Zwevezele, Belgium Tel: +44 (0)1928 571 444 • Fax: +44 (0)1928 571 488 E-mail: [email protected] • Website: www.joriside.co.uk and factories at: Kortrijksestraat 505, B-8020 Oostkamp, Belgium
and Bosveldstraat 4, B-8750 Zwevezele, Belgium Quality System Cert. No. 700 Assessed to ISO 9001:2008 Scope: Sales, design, fabrication & supply of steel construction materials (roof & wall panels, roof tiles, technical profiles, galvanized profiles & insulating sandwich panels).
Nanjing Fire Protection Technology Co Limited 12 Shiyang Road, Baixia District, Nanjing, China Tel: 86 25 842 79156 • Fax: 86 25 842 79101 E-mail: [email protected] Quality System Cert. No. 874 Assessed to Factory Production Control to PN 111 Scope: Manufacture of fire sprinklers.
National Fire Fighting Manufacturing Company Limited (NAFFCO) PO Box 17014, Jebel Ali, Dubai, United Arab Emirates Tel: +9714 881 5653 • Fax: +9714 881 6229 E-mail: [email protected] • Website: www.naffco.com Quality System Cert. No. 463 Assessed to ISO 9001:2008 Scope: Design, manufacture, installation and servicing of portable fire extinguishers, mobile fire extinguishers, auto extinguishing systems, fire hoses, hose reels and fire cabinets. Design and assembly of fire pumps, fire pump sets and fire hydrants. Design, manufacture, installation and servicing of water supply systems, fire sprinklers, water spray, foam systems and gaseous fixed fire fighting systems. Supply of fire blankets. Manufacture of dry riser inlet boxes to BS 5041-5.
National Sprinkler Company Limited Unit 4B, Fingal Bay Business Park, Balbriggan, Co Dublin, Ireland Tel: +353 1 690 4001/4040 • Fax: +353 1 841 7400 E-mail: [email protected] • Website: www.nationalsprinkler.ie Quality System Cert. No. 772 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
588
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Nexans Turkiye Endustri ve Ticaret A.S. Izmir Karayolu Uzeri 6.km, Denizli, Turkey Tel: 0090 212 266 0160 • Fax: 0090 212 266 0170 E-mail: [email protected] • Website: www.nexans.com.tr Quality System Cert. No. 946 Assessed to Factory Production Control to PN 111 Scope: The manufacture and supply of electric cables and wires, including cables that are used in installations which require safety in the event of fire.
NIBCO Inc 105 Quality Court, Charlestown, IN 471111-1149, United States Tel: +1 812 256 8530 • Fax: +1 812 256 8585 Also at: 701, Eisenhower Drive North, Goshen, Indiana 46526, United States Tel: +1 574 296 1240 • Fax: +1 574 296 1241 Quality System Cert. No. 878 Assessed to Factory Production Control to PN 111 Scope: Manufacture of CPVC fittings for fire sprinkler systems.
Nields Plastic Company Limited Units 1 -2, Foley Works Estate, Hereford HR1 2SF, United Kingdom Tel: +44 (0)1432 268341 • Fax: +44 (0)1432 353247 E-mail: [email protected] Quality System Cert. No. 342 Assessed to ISO 9001:2008 Scope: Manufacture of low density polythene film including coloured, printed, anti-static, conductive and flame retardant to customer specification: film thickness from 12.5 to 375 microns and widths from 50mm (2 inches) to 1524mm (60 inches). Material supplied on reels in the form of lay flat tube, centre folded sheet, double wound sheet, single wound sheet, pre-formed lay flat tube, or converted into bags.
Nitin Fire Protection Industries Limited A-117, T.T.C. Industrial Area, Pawane, Navi Mumbai - 400 701, Maharashtra, India Tel: +91 22 7633796 E-mail: [email protected] Also at: 29, Vadhani Estate, L.B.S. Marge, Ghatkoper (West), Mumbai - 400 086, Maharashtra, India
And D-20/4, T.T.C. Industrial Estate, Turbhe, Navi Mumbai - 400 701, Maharashtra, India Quality System Cert. No. 855 Assessed to Factory Production Control to PN 111 Scope: Procurement and supply of gaseous fire fighting components. Procurement, filling, supply and assembly of gaseous fixed fire fighting systems.
20 Nov 2011
589
PART 6: SECTION 1 QUALITY SYSTEMS
Nittan (UK) Limited Hipley Street, Old Woking, Surrey GU22 9LQ, United Kingdom Tel: +44 (0)1483 769555/8 • Fax: +44 (0)1483 756686 E-mail: [email protected] • Website: www.nittan.co.uk Quality System Cert. No. 041 Assessed to ISO 9001:2008 Scope: The manufacture of fire detection, alarm and monitoring equipment.
Nittan Fire Protection System (Zhongshan) Company, Limited The 2nd Floor, No. 29 Factory Building, New Concentrated Constructed Quarter, Zhongshan Torch Hi-Tech Industrial Dvlpmnt Zone, Zhongshan, Guangdong 528437, China Tel: +86 760 828 5700 • Fax: +86 760 828 1000 Quality System Cert. No. 842 Assessed to ISO 9001:2008 Scope: Manufacture of smoke detectors and their ancillaries.
NMC (UK) Limited Tafarnaubach Industrial Estate, Tredegar, South Wales NP22 3AA, United Kingdom Tel: +44 (0)800 834 704 • Fax: +44 (0)800 834 705 E-mail: [email protected] • Website: www.protection.co.uk Quality System Cert. No. 634 Assessed to ISO 9001:2008 Scope: The manufacture and supply of cellular polymers in extruded tube and profiles form including the supply of foam and polyurethane decorative products. The manufacture of fire retardent tubing and profiles.
No Climb Products Limited Edison House, 163 Dixons Hill Road, Welham Green, Hertfordshire AL9 7JE, United Kingdom Tel: +44 (0)1707 282760 • Fax: +44 (0)1707 282777 E-mail: [email protected] • Website: www.noclimb.com Quality System Cert. No. 813 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection test equipment.
Nobel Fire Systems Unit 6 Southgate Industrial Estate, Green Lane, Heywood, Lancashire OL10 1ND, United Kingdom Tel: +44 (0)1706 625 777 • Fax: +44 (0)1706 625 325 E-mail: [email protected] • Website: www.nobel-fire-systems.com Quality System Cert. No. 642 Assessed to ISO 9001:2008 Scope: Design, supply, installation, commissioning & servicing of gas generator, foam, dry chemical, gaseous, watermist & particulate aerosol fire suppression systems.
590
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Northern Ireland Plastics Limited 39 Shrigley Road, Killyleagh, Co. Down, Northern Ireland BT30 9SR, United Kingdom Tel: +44 (0)2844 828753/4 • Fax: +44 (0)2844 828809 E-mail: [email protected] Quality System Cert. No. 341 Assessed to ISO 9001:2008 Scope: Manufacture of twin wall polypropylene sheet.
Notifier Fire Systems by Honeywell Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United Kingdom Tel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888 E-mail: [email protected] • Website: www.notifierfiresystems.co.uk Quality System Cert. No. 154 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm systems and components.
Nu-Form Fire UK Limited 390 Manchester Road, Gollinrod, Bury, Lancashire BL9 5NB, United Kingdom Tel: +44 (0)1706 825111 • Fax: +44 (0)1706 827111 E-mail: [email protected] • Website: www.sprinklersystems.co.uk Quality System Cert. No. 214 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Olympic Fire Protection Limited Fire House, Mayflower Close, Chandlers Ford, Eastleigh, Hampshire SO53 4AR, United Kingdom Tel: +44 (0)870 608 4350 • Fax: +44 (0)870 608 4351 E-mail: [email protected] • Website: www.olympicfire.co.uk Quality System Cert. No. 173 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems, hosereels, dry risers and hydrants.
Pace Technology Co. Limited The Sanlian Industrial Estate of Gulao Town, Heshan City, Guangdong Province, China Tel: +852 917 66779 • Fax: +852 237 45126 E-mail: [email protected] Quality System Cert. No. 656 Assessed to ISO 9001:2008 Scope: Design and manufacture of blanket control and heating under-blanket and manufacture of carbon monoxide detectors.
20 Nov 2011
591
PART 6: SECTION 1 QUALITY SYSTEMS
Panel Projects Limited Portview Road, Avonmouth, Bristol BS11 9LQ, United Kingdom Tel: +44 (0)117 316 7000 • Fax: +44 (0)117 316 7001 Quality System Cert. No. 881 Assessed to ISO 9001:2008 Scope: Manufacture and supply of composite insulation and fire retardant panels.
Paroc Panel System Oy Ab FIN-21600, Parainen, Finland Tel: +358 46 876 8000 • Fax: +358 46 876 8702 E-mail: [email protected] • Website: www.paroc.com Quality System Cert. No. 381 Assessed to ISO 9001:2008 Scope: Manufacture of fire resistant composite panels.
Patterson Pump Ireland Limited Unit 14, Mullingar Business Park, Mullingar, Co Westmeath, Ireland Tel: +353 44 47078 • Fax: +353 44 47896 E-mail: [email protected] • Website: www.ie.pattersonpumps.com Quality System Cert. No. 436 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire pump sets. Manufacture of fire pumps.
PEL Services Limited Belvue Business Centre, Belvue Road, Northolt, Middlesex UB5 5QQ, United Kingdom Tel: +44 (0)20 8839 2100 • Fax: +44 (0)20 8841 1948 E-mail: [email protected] • Website: www.pel.co.uk Quality System Cert. No. 981 Assessed to ISO 9001:2008 Scope: Design, supply, installation and commissioning of public address, fire alarm, security and communications equipment.
Pendle Designs Limited Pendle House, Webb Street, Bury, Lancs BL8 1AF, United Kingdom Tel: +44 (0)161 764 2252 • Fax: +44 (0)161 763 1429 E-mail: [email protected] Quality System Cert. No. 138 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems. Manufacture of fabricated pipework for fire sprinkler systems.
592
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Peripheral Support Services Limited Unit 14, Enterprise Court, Rankine Road, Basingstoke, Hampshire RG24 8GE, United Kingdom Tel: +44 (0)1256 844 685 • Fax: +44 (0)1256 810 082 E-mail: [email protected] • Website: www.pss-firequest.co.uk Quality System Cert. No. 888 Assessed to ISO 9001:2008 Scope: Design, manufacture, test and repair of fire control systems, emergency lighting control systems and LST radiator covers and accessories.
Pittway Tecnologica Srl. Via Caboto 19/3, 34147 Trieste, Italy Tel: +39 040 94 90111 • Fax: +39 040 38 2137 E-mail: [email protected] • Website: www.systemsensoreurope.com European Sales: System Sensor Europe, Life Safety Distribution AG, Wilstrasse 11 (Building U31), CH-8610 Uster, Switzerland Tel: +41 44 943 4424 • Fax: +41 44 943 4399 E-mail: [email protected] • Website: www.systemsensoreurope.com Quality System Cert. No. 199 Assessed to ISO 9001:2008 Scope: Design, development and manufacture of control and signalling devices for fire prevention systems and gas detectors.
Potter Electric Signal Company 1609 Park 370 Place, Hazelwood, St Louis, Missouri 63042, United States Tel: +1 314 595 6900 • Fax: +1 314 595 6999 E-mail: [email protected] • Website: www.pottersignal.com Quality System Cert. No. 125 Assessed to ISO 9001:2008 Scope: Design and manufacture of electric alarm pressure switches and water flow alarm switches.
Powershield Doors Limited 21 Ferguson Drive, Knockmore Hill Industrial Park, Lisburn, Northern Ireland BT28 2EX, United Kingdom Tel: +44 (0)28 9266 2200 • Fax: +44 (0)28 9260 3600 E-mail: [email protected] • Website: www.powershield.co.uk Quality System Cert. No. 852 Assessed to ISO 9001:2008 Scope: Manufacture and installation of industrial doors, fire doors and windows.
Pressex UK Limited Kingsway South, Team Valley, Gateshead, Tyne & Wear NE11 0SH, United Kingdom Tel: +44 (0)191 497 3430 • Fax: +44 (0)191 497 3431 E-mail: [email protected] • Website: www.responsive-engineering.com Quality System Cert. No. 870 Assessed to Factory Production Control to PN 111 Scope:
20 Nov 2011
593
PART 6: SECTION 1 QUALITY SYSTEMS Manufacture and supply of anti duress mechanical and electromechanical devices for ATM security.
Professional Barrier Systems Limited 16 Stapledon Road, Orton Southgate, Peterborough PE2 6TD, United Kingdom Tel: +44 (0)1733 361511 • Fax: +44 (0)1733 361512 E-mail: [email protected] • Website: www.extendor.co.uk Quality System Cert. No. 869 Assessed to ISO 9001:2008 Scope: The design, manufacture and installation of barrier systems.
Project Fire Products Limited (incorporating Project Fire Engineers) Pasturefields Lane Industrial Estate, Pasturefields Lane, Hixon, Staffordshire ST18 0PH, United Kingdom Tel: +44 (0)1889 270999 • Fax: +44 (0)1889 270974 E-mail: [email protected] • Website: www.projectfire.co.uk Quality System Cert. No. 060 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler and water spray systems. Assembly, installation and commissioning, repair and servicing of water flow switch and alarm valve testing devices.
Protec Camerfield Limited 5 Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717474 • Fax: +44 (0)1282 717475 E-mail: [email protected] • Website: www.protec.co.uk Quality System Cert. No. 268 Assessed to ISO 9001:2008 Scope: Design, installation, service and maintenance of fire sprinkler systems and gaseous extinguishing systems.
Protec Fire Detection plc Protec House, Churchill Way, Nelson, Lancashire BB9 6RT, United Kingdom Tel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273 E-mail: [email protected] • Website: www.protec.co.uk Quality System Cert. No. 201 Assessed to ISO 9001:2008 Scope: Design, manufacture, installation, commissioning and servicing of fire detection and alarm systems and components. The following locations are included within the scope of certification: Swanley Unit 4 White Oak Square London Road Swanley Kent BR8 7AG Fareham Unit 10 Fulcrum 4 Solent Way Fareham Hampshire PO15 7FT
594
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS Leeds Unit 1, Ashfield Court Whitehall Road Leeds LS12 5JB Tel: 0845 456 5388 Cannock 5 Morston Court Blakeney Way Kingswood Lakeside Cannock Staffordshire WS11 8JB
Protec International Limited Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601 E-mail: [email protected] • Website: www.protection.co.uk Quality System Cert. No. 843 Assessed to ISO 9001:2008 Scope: The procurement and supply of specialist temporary protection materials and scaffold cladding materials. Flame retardant products for building and construction industry.
Provincial Sprinkler Co. Limited Unit 4, Cork Airport Industrial Estate, Kinsale Road, Cork, Ireland Tel: +353 (0)21 4965058 • Fax: +353 (0)21 4317425 E-mail: [email protected] • Website: www.provincial-sprinkler.ie Quality System Cert. No. 440 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Prysmian Cables & Systems Limited Energy Cables Unit, Wrexham Industrial Estate, Wrexham LL13 9PH, United Kingdom Tel: +44 (0)1978 662345 • Fax: +44 (0)1978 662292 E-mail: [email protected] • Website: www.prysmian.co.uk Quality System Cert. No. 517 Assessed to ISO 9001:2008 Scope: Manufacture of electrical cable for installations that require safety in the event of a fire.
Prysmian Cables & Systems Ltd Energy Cables, Chickenhall Lane, Bishopstoke, Eastleigh, Hants SO50 6YU, United Kingdom Tel: +44 (0)8457 678345 • Fax: +44 (0)2380 295465 E-mail: [email protected] • Website: www.prysmian.co.uk Overseas: Tel: +44 (0)2380 295555 Quality System Cert. No. 077 Assessed to ISO 9001:2008 Scope: Design and manufacture of electric cable for use in installations that require safety in the event of fire.
20 Nov 2011
595
PART 6: SECTION 1 QUALITY SYSTEMS
Prysmian Power Cables & Systems Australia Pty Limited 1 Heathcote Road, Liverpool, Sydney, New South Wales 2170, Australia Tel: +61 2 9600 0777 • Fax: +61 2 9600 0303 Website: www.pirelli.com Quality System Cert. No. 422 Assessed to ISO 9001:2008 Scope: Design and manufacture of cables for use in installations that require safety in the event of fire.
PSF Wales Limited Llys Rhiannon, Cil Yr Ychen Industrial Estate, Landeilo Road, Llandybie, Ammanford, Carmarthenshire SA18 3GY, United Kingdom Tel: +44 (0)1269 851777 • Fax: +44 (0)1269 851747 E-mail: [email protected] • Website: www.psfwales.co.uk Quality System Cert. No. 953 Assessed to ISO 9001:2008 Scope: The design and manufacture of sheet metalwork, fabrications and security doors.
Qinhuangdao Taidy Flex-Tech Co. Ltd No. 5 Yongdinghe Road, Qinhuangdao Economic & Technology Development Zone, Hebei 066004, China Tel: +86 335 8586186 • Fax: +86 335 8586190 E-mail: [email protected] • Website: www.taidy.com Quality System Cert. No. 764 Assessed to Factory Production Control to PN 111 Scope: Manufacture of "FlexHead" flexible hoses for fire sprinkler systems.
Quinn Therm Limited Scotchtown, Ballyconnell, Co. Cavan, Ireland Tel: +353 49 952 5604 • Fax: +353 49 952 5601 E-mail: [email protected] • Website: www.quinn-therm.com Quality System Cert. No. 893 Assessed to Factory Production Control to PN 111 Scope: Manufacture of flat roof systems.
R & S Fire & Security Services Limited Trafalgar House, 712 London Road, Grays, West Thurrock, Essex RM20 3JT, United Kingdom Tel: +44 (0)1708 683040 • Fax: +44 (0)1708 683068 E-mail: [email protected] • Website: www.rs-fire.com Quality System Cert. No. 1057 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning and servicing of fire detection and alarm gas extinguishing systems.
596
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
RAMCRO S.p.A Via Marzorati, 15 - 20014 Nerviano, Milan, Italy Tel: +39 0331 406560 • Fax: +39 0331 406559 E-mail: [email protected] Quality System Cert. No. 568 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of electric cables including cables used for installations that require safety in the event of fire and the supply of fibre optic cables.
Rapidrop Global Limited Rutland Business Park, Newark Road, Peterborough PE1 5WA, United Kingdom Tel: +44 (0)1733 847 510 • Fax: +44 (0)1733 553 958 E-mail: [email protected] • Website: www.rapidrop.com Quality System Cert. No. 566 Assessed to ISO 9001:2008 Scope: Design, manufacture and testing of fire protection equipment including fire sprinklers, valves and fire sprinkler systems components sub assemblies. Procurement, stockholding and supply of fire system products and manual fire extinguishing equipment.
Red Rose Fire Protection Limited Unit 2, Atlas Foundry Estate, Brieryfield Road, Preston PR1 8SR, United Kingdom Tel: +44 (0)1772 822133 • Fax: +44 (0)1772 822144 E-mail: [email protected] Quality System Cert. No. 384 Assessed to ISO 9001:2008 Scope: Design and installation of fire sprinkler systems.
Reliable Fire Sprinkler Limited Unit 25, Birches Industrial Estate, East Grinstead RH19 1XZ, United Kingdom Tel: +44 (0)1342 316800 • Fax: +44 (0)1342 314679 E-mail: [email protected] • Website: www.reliablesprinkler.com Quality System Cert. No. 140 Assessed to ISO 9001:2008 Scope: Stockholding and supply of fire sprinklers, fire protection valves and related products for fire sprinkler and water spray systems.
20 Nov 2011
597
PART 6: SECTION 1 QUALITY SYSTEMS
Retainagroup Limited Unit 5, St John's Court, Foster Road, Ashford Business Park, Ashford, Kent TN24 0SJ, United Kingdom Tel: +44 (0)1233 506400 • Fax: +44 (0)1233 506401 E-mail: [email protected] • Website: www.retainagroup.com Also included within the scope of certification Unit 2, Highpoint Business Village, Henwood, Ashford, Kent TN24 8DH 5 Windward House, Plantation Wharf, London SW11 3TU, United Kingdom Tel: +44 (0)20 7801 4800 • Fax: +44 (0)20 7801 4801
24 hour Telephone Number: 07000 111333 Quality System Cert. No. 493 Assessed to ISO 9001:2008 Scope: Manufacture of security marking devices and registration of items of property.
RGB Integrated Services Limited 223-236 Claremont House, Nestle Avenue, Hayes, Middlesex UB3 4SH, United Kingdom Tel: +44 (0)208 573 9882 • Fax: +44 (0)208 711 3916 E-mail: [email protected] • Website: www.rgb-services.com Quality System Cert. No. 1074 Assessed to ISO 9001:2008 Scope: Design, installation, testing, inspection and commissioning of electrical installations and design, installation, commissioning and servicing of fire detection and alarm systems.
RGT Fire Protection Limited 95 Beaumont Road, Bournville, Birmingham B30 2EB, United Kingdom Tel: +44 (0)121 433 5175 • Fax: +44 (0)121 486 1847 E-mail: [email protected] Quality System Cert. No. 745 Assessed to ISO 9001:2008 Scope: Design, installation and commissioning of fire sprinkler systems.
Richmond Fire Engineers Limited 30 Firby Road, Gallowfields Trading Estate, Richmond, North Yorkshire DL10 4ST, United Kingdom Tel: +44 (0)1748 825612 • Fax: +44 (0)1748 825935 E-mail: [email protected] • Website: www.richmondfire.co.uk Quality System Cert. No. 297 Assessed to ISO 9001:2008 Scope: Design, installation and service of fire sprinkler systems.
598
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
RMD Fire Control Limited The Coach House, 22 Lower Stone Street, Maidstone, Kent ME15 6LX, United Kingdom Tel: +44 (0)1622 682522 • Fax: +44 (0)1622 692675 E-mail: [email protected] • Website: www.rmdfire.co.uk Quality System Cert. No. 102 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems, hose reels and dry risers.
Robust UK Limited Brookhouse Way, Brookhouse Industrial Estate, Cheadle, Stoke-on-Trent, Staffordshire ST10 1SR, United Kingdom Tel: +44 (0)1538 752600 • Fax: +44 (0)1538 752604 E-mail: [email protected] • Website: www.robust-uk.com Factory: Unit 9B, Blythe Park, Sandon Road, Creswell, Stoke-on-Trent, Staffordshire ST11 9RD, United Kingdom Quality System Cert. No. 1070 Assessed to ISO 9001:2008 Scope: Manufacture and supply of doorsets for customers and or published requirements.
Rockwool Limited Wern Tarw, Pencoed, Bridgend, Mid Glamorgan CF35 6NY, United Kingdom Tel: +44 (0)1656 862621 • Fax: +44 (0)1656 862302 E-mail: [email protected] • Website: www.rockwool.co.uk Quality System Cert. No. 022 Assessed to ISO 9001:2008 Scope: The design and manufacture of stone wool products and systems.
Rolland Sprinklers Usine de 73410, Mognard, France Tel: +33 479 547 250 • Fax: +33 479 547 248 E-mail: [email protected] Quality System Cert. No. 295 Assessed to ISO 9001:2008 Scope: Manufacture of fire sprinklers.
Ross Fire Protection Limited 29 Deerdykes View, Westfield, Cumbernauld G68 9HN, United Kingdom Tel: +44 (0)1236 738502 • Fax: +44 (0)1236 727977 E-mail: [email protected] • Website: www.rossfire.co.uk Quality System Cert. No. 124 Assessed to ISO 9001:2008 Scope: Design, installation and service of fire sprinkler and water spray systems.
20 Nov 2011
599
PART 6: SECTION 1 QUALITY SYSTEMS
Rotary Firematic Limited 5 Trench Road, Mallusk Industrial Estate, Newtownabbey, Co Antrim, Northern Ireland BT36 8XA, United Kingdom Tel: +44 (0)2890 831200 • Fax: +44 (0)2890 831201 E-mail: [email protected] Quality System Cert. No. 107 Assessed to ISO 9001:2008 Scope: Design and installation of fire sprinkler systems. Fabrication of pipework for fire sprinkler systems.
Rotherham CNC Ltd Unit 30 Orgreave Close, Dore House Industrial Estate, Handsworth, Sheffield S13 9NP, United Kingdom Tel: +44 (0)114 269 9800 • Fax: +44 (0)114 269 7949 E-mail: [email protected] Quality System Cert. No. 778 Assessed to ISO 9001:2008 Scope: Provision of engineered precision components.
RSM Refko Installations Limited Unit 8, Capstan Centre, Thurrock Park Way, Tilbury, Essex RM18 7HH, United Kingdom Tel: +44 (0)1375 855500 • Fax: +44 (0)1375 855533 E-mail: [email protected] Quality System Cert. No. 336 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems. Installation of gaseous fire extinguishing systems.
Ruukki Polska Sp. Z.o.o. Lukowska 7/9 Street, Oborniki, Wielkopolskie, 64-600, Poland Tel: +48 61 296 8510 • Fax: +48 61 296 8545 Website: www.ruukki.com Quality System Cert. No. 1052 Assessed to ISO 9001:2008 Scope: Sandwich panels with PIR core for external claddings, roof coverings and partition walls.
S.F.S. FIRE SERVICES LIMITED (trading as Hall & Kay Fire Engineering and Chubb Fire Mechanical Division) 1st Floor, Sefton Lodge, Clewer Hill Road, Windsor SL4 4FT, United Kingdom Tel: +44 (0)1753 833444 • Fax: +44 (0)1753 833434 E-mail: [email protected] • Website: www.hkfire.co.uk Quality System Cert. No. 223 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems, hydrants, hose reels and dry/wet risers together with the supply and servicing of fire extinguishers. Supply of fire fighting products.
600
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
S.F.S. Fire Services Ltd, T/A Hall & Kay Fire Engineering 3 Peerglow Centre, Marsh Lane, Ware, Hertfordshire SG12 9QL, United Kingdom Tel: +44 (0)1920 460616 • Fax: +44 (0)1920 461113 E-mail: [email protected] • Website: www.hkfire.co.uk Quality System Cert. No. 1055 Assessed to ISO 9001:2008 Scope: Design and installation of fire sprinkler systems.
Safe Partnership 3 East Street, Wareham, Dorset BH20 4NN, United Kingdom Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300 E-mail: [email protected] • Website: www.safepartnership.co.uk Quality System Cert. No. 835 Assessed to ISO 9001:2008 Scope: Manufacture, supply, installation, maintenance and repair of timber door sets. Supply, installation, maintenance and repair of domestic physical security products.
SafeGuard Doors, A Division of Adams Rite Europe Limited School Street, Willenhall, West Midlands WV13 3PW, United Kingdom Tel: +44 (0))1902 364601 • Fax: +44 (0)1902 364602 E-mail: [email protected] • Website: www.safeguarddoors.co.uk Quality System Cert. No. 661 Assessed to ISO 9001:2008 Scope: Manufacture and installation of security, bullet resistant, blast effect and fire doors.
Safeguard Security, a trade name of WBH Industries Unit 5, 229 Torrington Avenue, Coventry CV4 9HN, United Kingdom Tel: +44 (0)2476 470 600 • Fax: +44 (0)2476 471 600 E-mail: [email protected] • Website: www.safeguardsecurity.co.uk Quality System Cert. No. 418 Assessed to ISO 9001:2008 Scope: Manufacture and installation of sliding security grilles.
Safety Hi-Tech Srl Via Cavour, 96 - 67051 Avezzano (AQ), Italy Tel: +39 0863 1940720 • Fax: +39 0863 1940724 E-mail: [email protected] • Website: www.safetyhitech.com Quality System Cert. No. 969 Assessed to Factory Production Control to PN 111 Scope: Production of components and halocarbon gases for fire suppression systems.
20 Nov 2011
601
PART 6: SECTION 1 QUALITY SYSTEMS
Safety Technology International (Europe) Limited Unit 49G Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire B98 0HU, United Kingdom Tel: +44 (0)1527 520999 • Fax: +44 (0)1527 501999 E-mail: [email protected] • Website: www.sti-europe.com Quality System Cert. No. 653 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire indicating equipment including products to protect fire and security equipment from theft and damage. Stock holding and supply of third party fire and security equipment.
Salisbury Glass Centre Limited Newton Road, Churchfields Industrial Estate, Salisbury, Wiltshire SP2 7QA, United Kingdom Tel: +44 (0)1722 342900 • Fax: +44 (0)1722 338784 E-mail: [email protected] or [email protected] • Website: www.salisbury-glass.com Quality System Cert. No. 947 Assessed to ISO 9001:2008 Scope: Manufacture, installation and service of aluminium and UPVC windows, doors, conservatories and glazed sealed units.
Sanwa Yoshida (JiaXing) Construction Material Industry Co., Ltd South Xitang Town, Jiashan County, Jiaxing City, Zheijang Province, China Tel: +86-573-4565888 • Fax: +86-573-84565988 E-mail: [email protected] • Website: www.yangmega.net Quality System Cert. No. 983 Assessed to ISO 9001:2008 Scope: Manufacture of non-combustable high performance building board.
SAPAG Industrial Valves 2 Rue du Marais, 80400 Ham, France Tel: +33 (0)323 810582 • Fax: +33 (0)323 814300 Quality System Cert. No. 571 Assessed to ISO 9001:2008 Scope: Design and manufacture of butterfly valves for fire protection systems application.
Saudi Factory For Fire Equipment Co. New Industrial Area, PO Box 58469, Riyadh 11515, Kingdom of Saudi Arabia Tel: +966 1 265 0070 • Fax: +966 1 265 2190 E-mail: [email protected] • Website: www.sffeco.com Quality System Cert. No. 403 Assessed to ISO 9001:2008 Scope: Design, manufacture, installation, maintenance, repair and servicing of fire extinguishing systems. Design, installation and maintenance of fire detection and alarm systems. Manufacture, installation, repair and servicing of portable fire extinguishers, hose reels and cabinets. Assembly of fire pumps, hydrants and controllers for fire pumps. Manufacture of fire doors.
602
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger, Southhampton) Unit 7, The Quadrangle, Abbey Park Industrial Estate, Romsey, Southampton, Hampshire SO51 9DL, United Kingdom Tel: +44 (0)1794 529600 • Fax: +44 (0)1794 514931 Website: www.slb.com Also at: Unit 5, The Quadrangle, Abbey Park Industrial Estate, Romsey, Hampshire SO51 9DL, United Kingdom
and Unit 8, The Quadrangle, Abbey Park Industrial Estate, Romsey, Hampshire SO51 9DL, United Kingdom Quality System Cert. No. 648 Assessed to ISO 9001:2008 Scope: Design, manufacture and repair of distributed temperature sensor devices.
Scotshield Limited Century House, Chapelhall Industrial Estate, Airdrie, Scotland ML6 8QH, United Kingdom Tel: +44 (0)1236 767788 • Fax: +44 (0)1236 762233 E-mail: [email protected] Quality System Cert. No. 614 Assessed to ISO 9001:2008 Scope: Design, installation, commissioning and maintenance of fire detection systems.
Security Blinds Limited Units 3 A/B, Hope Street, Thornhill Industrial Estate, Rotherham S60 1LH, United Kingdom Tel: +44 (0)1709 363535 • Fax: +44 (0)1709 364512 E-mail: [email protected] • Website: www.securityblinds.co.uk Quality System Cert. No. 854 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of security blinds.
Sekisui Aqua Systems Company Limited 77 Kami-Onogo, Iwata City, Shizuoka Prefecture 438, Japan Tel: +81 5 3835 0101 • Fax: +81 5 3836 2229 Website: www.sps-int.com Quality System Cert. No. 242 Assessed to ISO 9001:2008 Scope: Manufacture of GRP sectional water storage tanks.
20 Nov 2011
603
PART 6: SECTION 1 QUALITY SYSTEMS
Select Fire Services Limited 10 Harolds Road, Harlow, Essex CM19 5BJ, United Kingdom Tel: +44 (0)1279 641979 • Fax: +44 (0)1279 641978 E-mail: [email protected] • Website: www.selectfire.co.uk Quality System Cert. No. 479 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Selectaglaze Limited Alban Park, Hatfield Road, St Albans, Hertfordshire AL4 0JJ, United Kingdom Tel: +44 (0)1727 837271 • Fax: +44 (0)1727 844053 E-mail: [email protected] • Website: www.selectaglaze.co.uk Quality System Cert. No. 683 Assessed to ISO 9001:2008 Scope: Design, manufacture, installation and service of secondary glazing systems.
Selectamark Security Systems plc 1 Locks Court, 429 Crofton Road, Locksbottom, Kent BR6 8NL, United Kingdom Tel: +44 (0)1689 860757 • Fax: +44 (0)1689 860693 E-mail: [email protected] • Website: www.selectadna.co.uk Quality System Cert. No. 497 Assessed to ISO 9001:2008 Scope: The manufacture and supply of property marking systems incorporating chemical etching, forensic marking, electronic identification and secure asset registration using electronic and hard copy systems.
Shaanxi J & R Fire Fighting Co Ltd Qingyang International Building, No 65, Keji 2nd Road, Gaoxin District, Xi'an, Shaanxi 710075, China Tel: +86 29 88332970 • Fax: +86 29 88332680 E-mail: [email protected] • Website: www.xajr.com Factory: No. 23, South of Weiyang Road, Jinwei New City, Economic and Technologic Development Zone, Xi'an, Shaanxi, China Quality System Cert. No. 1049 Assessed to ISO 9001:2008 Scope: Design, manufacture and after service of gas (aerosol) fire-extinguishing systems, accessories and fittings.
Shakun Polymers Limited (Cable Division), Plot No. 4, Silver Industrial Estate, Bhimpore, Patalia Road, Daman 396 210, India Tel: +91 260 222 1538 • Fax: +91 260 222 1199 E-mail: [email protected] • Website: www.shakuncables.com Quality System Cert. No. 978 Assessed to Factory Production Control to PN 111 Scope: Manufacturing of insulated fire resistant wires and cables.
604
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Shellcast Systems Limited Camel House, Six Ashes, Bridgnorth WV15 6ER, United Kingdom Tel: +44 (0)1562 750 700 • Fax: +44(0)8712 453 553 E-mail: [email protected] • Website: www.shellcast-shutters.co.uk Quality System Cert. No. 707 Assessed to ISO 9001:2008 Scope: Supply, installation, commissioning, service and repair of security shutters.
ShenZhen CICAM Manufacturing Co Ltd Building 11, Wanxia Industry Garden, Tongfuyu Industry District, Shajing Street, Bao An District, Shenzhen 518104, China Tel: +852 2596 7711 • Fax: +852 2586 1600 E-mail: [email protected] Quality System Cert. No. 668 Assessed to ISO 9001:2008 Scope: Design and manufacture of radioactive based industrial and domestic smoke detection ionization chambers and components. Manufacture of industrial and domestic smoke alarms and associated products.
Shurjoint Metals Inc. No 295, Sec 3, Wantan Road, Wantan Township, Pingtung County, Taiwan ROC Tel: +886 8 752 5877 • Fax: +886 8 753 0227 Quality System Cert. No. 448 Assessed to ISO 9001:2008 Scope: Manufacture of pipe couplings and fittings.
Siemens plc, Building Technologies, Fire Safety Division Brunel House, Sir William Siemens Square, Frimley, Camberley, Surrey GU16 8QD, United Kingdom Tel: +44 (0)1276 696000 • Fax: +44 (0)1276 696133 E-mail: [email protected] • Website: www.siemens.co.uk/buildingtechnologies Also at: 7th Floor, Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock, Staffordshire WS11 0XE, United Kingdom Tel: +44 (0)1543 435500 • Fax: +44 (0)1543 435525 Quality System Cert. No. 616 Assessed to ISO 9001:2008 Scope: Frimley:- Design, installation, commissioning and servicing of fire detection, alarm systems and gaseous fire extinguishing systems. Service and maintenance of fire sprinkler, deluge, water spray, foam, hose reels and hydrants. Cannock:- Design, installation, commissioning and servicing of fire detection, alarm systems and gaseous fire extinguishing systems. Maintenance of portable fire extinguishers.
20 Nov 2011
605
PART 6: SECTION 1 QUALITY SYSTEMS
Siemens Switzerland Limited, Building Technologies Division International Headquarters, Gubelstrasse 22, CH-6301 Zug, Switzerland Tel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22 Quality System Cert. No. 126 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm equipment and electronic security equipment. Design and assembly of fire extinguishing equipment. The following locations are included within the scope of certification:Factory Volketswil CH-8604 Volketswil, Switzerland Factory Altenrhein CH-9423 Altenrhein, Switzerland Factory Buc F-78531 Buc, France Scope: Manufacture and repair of fire and security detection and alarm systems and components. The following location is included within the scope of certification:Factory Berlin D-13629 Berlin, Germany
SigNET AC Limited 6 Tower Road, Glover Industrial Park, Washington, Tyne & Wear NE37 2SH, United Kingdom Tel: +44 (0)191 417 4551 • Fax: +44 (0)191 417 0634 E-mail: [email protected] • Website: www.signet-ac.co.uk Quality System Cert. No. 1082 Assessed to ISO 9001:2008 Scope: Manufacture of voice/PA equipment; audio frequency induction loop equipment. Disabled refuge emergency evacuation equipment.
Simbars (UK) Limited Unit 2, 46 Ashton Vale Road, Ashton, Bristol BS3 2HQ, United Kingdom Tel: +44 (0)117 953 1444 • Fax: +44 (0)117 963 1444 E-mail: [email protected] • Website: www.simbars.co.uk Quality System Cert. No. 932 Assessed to ISO 9001:2008 Scope: The design, manufacture and installation of water borehole security kiosks including enclosures and gates. Fabrication of small and medium sized metal products used as street furniture for security and pedestrian use.
606
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
SMP Security Limited Halesfield 24, Telford, Shropshire TF7 4NZ, United Kingdom Tel: +44 (0)1952 585673 • Fax: +44 (0)1952 582816 E-mail: [email protected] • Website: www.smpsecurity.co.uk Quality System Cert. No. 115 Assessed to ISO 9001:2008 Scope: The design, manufacture and installation of secure storage enclosures, strongroom doors, associated products and services.
Solent Fire Protection Services Limited 12 Heritage Business Park, Heritage Way, Gosport, Hampshire PO12 4BG, United Kingdom Tel: +44 (0)2392 510230 • Fax: +44 (0)2392 511510 E-mail: [email protected] • Website: www.solentfire.co.uk Quality System Cert. No. 220 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Sotech Limited 2 Traynor Way, Whitehouse Business Park, Peterlee, County Durham SR8 2RU, United Kingdom Tel: +44 (0)191 587 2287 • Fax: +44 (0)191 518 0703 E-mail: [email protected] • Website: www.sotech-optima.co.uk Quality System Cert. No. 770 Assessed to ISO 9001:2008 Scope: Manufacture of rain screen cladding panels, louvre units, gutter flashings, fascia and soffit details and bent metal components for construction. Sub-contract metal bending.
Southern Grille & Gate Limited Unit 4, Eagle Trading Estate, 29 Willow Lane, Mitcham, Surrey CR4 4UY, United Kingdom Tel: +44 (0)208 640 9989 • Fax: +44 (0)208 640 4108 E-mail: [email protected] • Website: www.sgg-ltd.co.uk Quality System Cert. No. 1037 Assessed to ISO 9001:2008 Scope: Manufacutre of steel doorsets and collapsible gates, roller shutters and grilles.
Spears Manufacturing Company Inc 15853 Olden Street, Sylmar, California 91342, United States Tel: +1 818 364 1611 • Fax: +1 818 364 6945 Website: www.spearsmfg.com Quality System Cert. No. 293 Assessed to ISO 9001:2008 Scope: Design and manufacture of injection moulded pipe fittings and valves.
20 Nov 2011
607
PART 6: SECTION 1 QUALITY SYSTEMS
Specialist Panels UK Limited Bolam Business Park, Bassington Drive, Bassington Industrial Estate, Cramlington, Northumberland NE23 8AD, United Kingdom Tel: +44(0) 1670 739116 • Fax: +44(0) 1670 732955 E-mail: [email protected] • Website: www.isowall.org.uk Quality System Cert. No. 957 Assessed to ISO 9001:2008 Scope: Manufacture of structural insulated panels.
SPIE Fire (A division of SPIE) 7-14 Great Dover Street, London SE1 4YR, United Kingdom Tel: +44 (0)20 7089 7350 • Fax: +44 (0)20 7089 7378 E-mail: [email protected] • Website: www.spiematthewhall.com Quality System Cert. No. 070 Assessed to ISO 9001 Scope: Design, installation and servicing of fire sprinkler and water spray systems. Design and installation of fire detection systems.
SPIE Fire (A division of SPIE) Unit 2, Focus Park, Ashbourne Way, Solihull, West Midlands B90 4QU, United Kingdom Tel: +44 (0)121 713 8113 • Fax: +44 (0)121 713 8198/8199 E-mail: [email protected] • Website: www.spiematthewhall.com Quality System Cert. No. 070-2 Assessed to ISO 9001 Scope: Design, installation and servicing of fire sprinkler systems. Small works and servicing of fire detection systems.
SPIE Matthew Hall Level 2, McCafferty House, 99 Firhill Road, Glasgow G20 7BE, United Kingdom Tel: +44 (0)141 945 8900 • Fax: +44 (0)141 945 8901 E-mail: [email protected] • Website: www.spiematthewhall.com Quality System Cert. No. 986 Assessed to ISO 9001:2008 Scope: Design, project management, installation and commissioning of fire suppression systems.
608
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
SPP Pumps Limited Sales & Services: Theale Cross, Pincents Lane, Calcot, Reading, Berkshire RG31 7SP, United Kingdom Tel: +44 (0)118 932 3123 • Fax: +44 (0)118 932 3302 E-mail: [email protected] • Website: www.spppumps.com
Design & Manufacture: Crucible Close, Muschet Industrial Park, Coleford, Gloucestershire GL16 8PS, United Kingdom Quality System Cert. No. 111 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of pumps, pump packages and generator sets, for use in construction, building services, oil and gas, and water industries, as well as general industry. Project management and the assembly of pump packages and generators including associated documentation. Service and provision of spare parts, repair and maintenance of pumps, valves, compressors and other allied equipment. The following locations are included within the scope of certification:Service Centres: Tufthorn Avenue, Coleford, Gloucestershire GL16 8PS UK Unit 1, Stanstead Road, Eastleigh, Hampshire SO50 4RZ UK Greg Street, Reddish, Stockport, Cheshire SK5 7BU UK Unit 2, Oakbank, Channel Commercial Park, Queens Road, Belfast, Northern Ireland BT3 9DT Scope: Installation, service and repair of fire pumps, pump packages and valves. PO Box 61491, Jebel Ali, Dubai, United Arab Emirates Scope: Testing and supply of LPCB approved fire pump sets. SPP Pumps Inc., 6716 Best Friend Road, Norcross, GA 30071, United States of America Scope: Supply and testing of pumps and pump sets. SPP Pumps (South Africa) (Pty), 6c Roller Street, Spartan Extension 7, Kempton Park, Gauteng, Johannesburg, RSA. Scope: Supply, manufacture and repair of pumps and pump sets.
Sprue Safety Products Ltd Vanguard Centre, Sir William Lyons Road, Coventry CV4 7EZ, United Kingdom Tel: +44 (0)2476 323232 • Fax: +44 (0)2476 693610 E-mail: [email protected] • Website: www.fireangel.co.uk Quality System Cert. No. 651 Assessed to ISO 9001:2008 Scope: Design and supply of domestic photo-electric, ionization smoke detectors and CO alarms.
20 Nov 2011
609
PART 6: SECTION 1 QUALITY SYSTEMS
Stanair Industrial Door Services Limited 2 Henson Way, Telford Way Industrial Estate, Kettering, Northamptonshire NN16 8PX, United Kingdom Tel: +44 (0)1536 482187 • Fax: +44 (0)1536 411799 E-mail: [email protected] • Website: www.stanair.co.uk Also at: Unit 11, Blundells Road, Bradville, Milton Keynes MK13 7HA, United Kingdom Tel: +44 (0)1908 222070 • Fax: +44 (0)1908 222621 Quality System Cert. No. 141 Assessed to ISO 9001:2008 Scope: Installation, servicing and repair of industrial doors and fire doors. Installation, servicing and repair of industrial rolling shutters and fire rolling shutters.
Stancold plc Portview Road, Avonmouth, Bristol BS11 9LQ, United Kingdom Tel: +44 (0)117 316 7000 • Fax: +44 (0)117 316 7001 E-mail: [email protected] • Website: www.stancold.co.uk Quality System Cert. No. 600 Assessed to ISO 9001:2008 Scope: Design, supply and installation of composite insulation and fire retardant panels and panel systems.
Static Systems Group Plc Heath Mill Road, Wombourne, Staffordshire WV5 8AN, United Kingdom Tel: +44 (0)1902 895551 • Fax: +44 (0)1902 324969 E-mail: [email protected] • Website: www.staticsystems.co.uk Quality System Cert. No. 053 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire alarm systems. Installation, commissioning and servicing of fire detection and alarm systems.
Steeltech Systems Limited Baris House, Nunn Brook Road, County Estate, Huthwaite, Nottinghamshire NG17 2HU, United Kingdom Tel: +44 (0)1623 441442 • Fax: +44(0)1623 441443 Quality System Cert. No. 985 Assessed to ISO 9001:2008 Scope: The design and fabrication of Dryvit Fedderlite External Thermal-Insulated Cladding (ETIC) System Panels.
STO AG Ehrenbachstrasse 1, D-79780, Stuhlingen, Germany Tel: +49 7744 571440 • Fax: +49 7744 572440 Quality System Cert. No. 749 Assessed to Factory Production Control to PN 111 Scope: External wall insulation systems plasters, concrete restoration and paints.
610
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Sunjüt A.S. Manufacturing Plant: Yesilbayir Mah, Hadimköy Istanbul yolu Cad. No: 59, 34555 P.K Arnavutköy Hadimköy, Istanbul, Turkey Tel: +90 216 365 3950 • Fax: +90 216 365 0663 Quality System Cert. No. 495 Assessed to ISO 9001:2008 Scope: Manufacture of flame retardant woven material.
Sunray Engineering Limited Kingsnorth Industrial Estate, Wotton Road, Ashford, Kent TN23 6LL, United Kingdom Tel: +44 (0)1233 639039 • Fax: +44 (0)1233 625137 E-mail: [email protected] • Website: www.sunraydoors.co.uk Quality System Cert. No. 234 Assessed to ISO 9001:2008 Scope: The design, manufacture, supply and installation of steel security doors, fire doors, commercial doors, industrial doors and louvre systems.
Supra UK Limited 24 The Furlong, Berry Hill Industrial Estate, Droitwich Spa, Worcestershire WR9 9AH, United Kingdom Tel: +44 (0)1905 770333 • Fax: +44 (0)1905 797773 E-mail: [email protected] • Website: www.keysafe.co.uk Quality System Cert. No. 1004 Assessed to ISO 9001:2008 Scope: Distribution and installation of key safes and cabinets.
Sure Lock Doors Limited Unit 4, Monarch Industrial Estate, 198 Kings Road, Tyseley, Birmingham, West Midlands B11 2AP, United Kingdom Tel: +44 (0)121 706 8400 • Fax: +44 (0)121 706 4399 E-mail: [email protected] • Website: www.surelockdoors.co.uk Quality System Cert. No. 1045 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of high security stainless steel and aluminium doors, door sets and interlocking systems.
20 Nov 2011
611
PART 6: SECTION 1 QUALITY SYSTEMS
Surelock McGill Group Incorporating: Surelock McGill Ltd, 25/26 The Business Centre, Molly Millars Lane, Wokingham, Berks RG41 2QY, United Kingdom
and Stafford Bridge Doors Ltd, Beford Road, Pavenham, Bedfordshire MK43 7OS, United Kingdom Quality System Cert. No. 516 Assessed to ISO 9001:2008 Scope: McGill Ltd, Wokingham: Design and manufacture of single point and multi point bolting and locking systems, heavy duty hinges and related equipment for fire, safety, security, blast and acoustic doors, windows, panels and hatches. Stafford Bridge Doors Ltd, Pavenham: Design, manufacture, supply and installation of security doors and door sets.
SuZhou Primetech Electronics Co Limited ChunFeng Road, Pan Yang Industrial Park, HuangDai Town, Xiang Cheng District, SuZhou City, JiangSu, China Tel: +86 512 6571 E-mail: [email protected] • Website: www.primetech-sz.com.cn Quality System Cert. No. 971 Assessed to ISO 9001:2008 Scope: Manufacture and repair of smoke, heat and gas detection alarms for domestic use.
SWS UK Hornby Road, Claughton, Lancaster LA2 9LA, United Kingdom Tel: +44 (0)1524 772400 • Fax: +44 (0)1524 772411 E-mail: [email protected] • Website: www.swsuk.co.uk Quality System Cert. No. 390 Assessed to ISO 9001:2008 Scope: Manufacture, installation and repair of industrial shutters, collapsible gates and window bars.
System Sensor 3825 Ohio Avenue, Saint Charles, Illinois 60174, United States Tel: +1 630 377 6580 • Fax: +1 630 377 7245 Website: www.systemsensor.com Quality System Cert. No. 118 Assessed to ISO 9001:2008 Scope: Design, manufacture of fire detection and alarm system components. Design and manufacture of waterflow alarm switches.
612
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
System Sensor de México S.A. de C.V. Ave. Valle del Cedro No. 1681, Parque Industrial Intermex, Ciudad Juárez, Chihuahua, CP 32574, Mexico Tel: +52 656 6240479 • Fax: +52 656 6240490 Website: www.systemsensor.com USA Office: Tel: +1 630 443 4242 • Fax: +1 630 443 4247 Quality System Cert. No. 859 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm system components. Manufacture of gas detection devices.
System Sensor Fire Detectors Volochaevskaya Ulitsa, 40 Building 2, 111033 Moscow, Russian Federation Tel: +7 495 937 7985 • Fax: +7 495 937 7983 E-mail: [email protected] Quality System Cert. No. 585 Assessed to ISO 9001:2008 Scope: Manufacture and servicing of fire detection and alarm system components.
System Sensor, Honeywell International (I) PVT. Limited Sector 36, Pace City - II, Gurgaon - 122 004, Haryana, India Tel: +91 124 6371770 • Fax: +91 124 6371713 E-mail: [email protected] Quality System Cert. No. 550 Assessed to ISO 9001:2008 Scope: Manufacture of fire detection and alarm system components.
Talentum Developments Limited Beal Lane, Shaw, Oldham, Lancashire OL2 8PF, United Kingdom Tel: +44 (0)1706 844714 • Fax: +44 (0)1706 882612 E-mail: [email protected] • Website: www.talentum.co.uk Quality System Cert. No. 729 Assessed to ISO 9001:2008 Scope: Design, manufacture and repair of spark and flame detectors.
TangoRail Limited Units 1-3,, Prothero Industrial Estate, Bilport Lane, Wednesbury, West Midlands WS10 0NT, United Kingdom Tel: +44 (0)844 8360008 • Fax: +44 (0)844 8360009 E-mail: [email protected] • Website: www.tangorail.com Quality System Cert. No. 942 Assessed to ISO 9001:2008 Scope: Supply of security fencing. and
20 Nov 2011
613
PART 6: SECTION 1 QUALITY SYSTEMS
Herons Way, Balby, Doncaster, DN4 8WA Scope: Design, manufacture and supply of security fencing systems.
Taylor Fire Sprinklers Limited Unit D, Avondale Way, Wakefield, West Yorkshire WF2 7QU, United Kingdom Tel: +44 (0)1924 375971 • Fax: +44 (0)1924 609902 E-mail: [email protected] • Website: www.taylorfiresprinklers.co.uk Quality System Cert. No. 990 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Quality System Cert. No. 450 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of access covers, doors, gratings, grilles, security enclosures, gas cylinder security devices and access systems including flooring, decking, support steel and hand railing.
Terofire Products Lion House, Lion Street, Congleton, Cheshire CW12 4BH, United Kingdom Tel: +44 (0)1260 297 578 • Fax: +44 (0)1260 290 078 E-mail: [email protected] • Website: www.terofire.com Quality System Cert. No. 799 Assessed to ISO 9001:2008 Scope: Stockholding and supply of fire alarm control and indicating equipment. Repair of control and indicating equipment.
Thameside Fire Protection Co. Limited Unit 4, Sovereign Business Park, Cranes Farm Road, Basildon, Essex SS14 3JD, United Kingdom Tel: +44 (0)1268 597999 • Fax: +44 (0)1268 597998 E-mail: [email protected] • Website: www.thamesidefire.co.uk Quality System Cert. No. 269 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems. Installation, repair and servicing of portable fire extinguishers. Fire alarm installation and servicing.
The Reliable Automatic Sprinkler Co., Inc, 1470 Smith Grove Road, Liberty, South Carolina 29657, United States Tel: +1 864 843 1734 • Fax: +1 864 843 1418 E-mail: [email protected] • Website: www.reliablesprinkler.com Quality System Cert. No. 034 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire sprinklers, alarm, dry and deluge valves and related products for fire sprinkler systems.
614
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
The Rooflight Company Wychwood Business Centre, Milton Road, Shipton-under-Wychwood, Oxfordshire OX7 6XU, United Kingdom Tel: +44 (0)1993 833108 • Fax: +44 (0)1993 831066 E-mail: [email protected] • Website: www.therooflightcompany.co.uk Also at: Bourton Industrial Park, Bourton on the Water, Gloucestershire GL54 2HQ, United Kingdom Quality System Cert. No. 929 Assessed to ISO 9001:2008 Scope: Design, manufacture, storage and distribution of pitched and flat rooflights.
The Viking Corporation 210 N Industrial Park, Hastings, Michigan 49058, United States Tel: +1 269 945 9501 • Fax: +1 269 945 9599 E-mail: [email protected] • Website: www.vikingcorp.com Also at: 11305 James Street, Holland, Michigan 49424, United States Quality System Cert. No. 096 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire sprinklers, fire protection valves and related products for fire sprinkler systems.
Thermotech Fire Protection Limited Unit 10, Bamford Business Park, Off Hibbert Street, Reddish, Stockport SK4 1PL, United Kingdom Tel: +44 (0)161 476 5551 • Fax: +44 (0)161 476 2998 E-mail: [email protected] • Website: www.thermotech-fireprotection.co.uk Quality System Cert. No. 829 Assessed to ISO 9001:2008 Scope: Design, installation and servicing of fire sprinkler systems.
Tindall Engineering Limited Abryll House, Wright Street (off Yorkshire Street), Oldham, Lancashire OL1 3TF, United Kingdom Tel: +44 (0)161 620 0666 • Fax: +44 (0)161 620 3966 Quality System Cert. No. 608 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of the MICO range of emergency exit hardware and high security multi-point locking hardware.
Total Polyfilm Limited Armytage Road, The Industrial Estate, Brighouse, West Yorkshire HD6 1PT, United Kingdom Tel: +44 (0)1484 714313 • Fax: +44 (0)1484 720452 Quality System Cert. No. 527 Assessed to Factory Production Control to PN 111 Scope: Manufacture and supply of low density flame retardant polythene sheeting.
20 Nov 2011
615
PART 6: SECTION 1 QUALITY SYSTEMS
Tratos Cavi SpA Via Stadio 2, Pieve S. Stefano 52036, Arezzo, Italy Tel: +39 0575 7941 • Fax: +39 0575 798026 E-mail: [email protected] • Website: www.tratos.it Quality System Cert. No. 222 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of electric cables for use in fire alarm systems.
Trellicor (Pty) Limited 20 Aberdare Drive, Phoenix Industrial Park, Durban, South Africa Tel: +27 31 500 4301 • Fax: +27 31 507 2129/3973 Quality System Cert. No. 474 Assessed to ISO 9001:2008 Scope: Design and manufacture of sliding security gates.
Trimetals Limited Sunrise Business Park, Higher Shaftesbury Road, Blandford Forum, Dorset DT11 8ST, United Kingdom Tel: +44 (0)1258 459441 • Fax: +44 (0)1258 480408 E-mail: [email protected] • Website: www.trimetals.co.uk Quality System Cert. No. 899 Assessed to Factory Production Control to PN 111 Scope: Design and manufacture of bicycle stores.
Twinplast Limited Unit 2, Greycaine Road, Watford, Hertfordshire WD24 7GP, United Kingdom Tel: +44 (0)1923 230191/817761 • Fax: +44 (0)1923 817756 E-mail: [email protected] • Website: www.twinplast.co.uk Quality System Cert. No. 375 Assessed to ISO 9001:2008 Scope: Manufacture of polypropylene twinwall sheet and associated conversion products.
Tyco Building Services Products B.V. Kopersteden 1, 7547 TJ Enschede, The Netherlands Tel: +31 53 4284444 • Fax: +31 53 4283377 E-mail: [email protected] • Website: www.tycobuilding.com Quality System Cert. No. 169 Assessed to ISO 9001:2008 Scope: Scope: Stockholding, supply and distribution of fire protection equipment including: -Sprinklers, valves and accessories -Hydrants, foam extinguishing system components -Pipe couplings, fittings and hangers -Metal framing and support systems to distributors and the construction industry -Assembly and test of fire protection valve stations
616
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS Central Spraysafe / Spraysafe Automatic Sprinklers Limited Unit 6, Westpoint Enterprise Park, Clarence Avenue, Trafford Park, Manchester M17 1QS, UK Tel: +44 (0)161 875 0400 Fax: +44 (0)161 875 0491 Scope: Supply of fire protection equipment. Assembly and pressure test of valve stations.
Tyco Fire & Building Products Research & Development Center, 1467 Elmwood Avenue, Cranston, RI 02910, United States Tel: +1 401 781 8220 • Fax: +1 401 781 7317 Quality System Cert. No. 570 Assessed to ISO 9001:2008 Scope: Research, design, development and manufacturing support for the fire protection equipment, pipe couplings, fittings, related piping system components and CPVC pipe and fitting manufactures of Tyco Fire and Building Products.
Tyco Fire & Building Products 8902 North Interstate 27, Lubbock, Texas 79403, United States Tel: +1 806 472 2400 • Fax: +1 806 806 8902 Quality System Cert. No. 094-2 Assessed to ISO 9001:2008 Scope: Manufacture of fire sprinklers and sprayers.
Tyco Fire & Building Products 245 Swancott Road, Madison, Alabama 35756, United States Tel: +1 256 464 5633 • Fax: +1 256 464 5635 Quality System Cert. No. 420 Assessed to ISO 9001:2008 Scope: Design and manufacture of CPVC pipe and fittings.
Tyco Fire & Building Products 260 Central Castings Drive, Anniston, AL 36206, United States E-mail: [email protected] • Website: www.tycobuilding.com Quality System Cert. No. 669 Assessed to ISO 9001:2008 Scope: Design and manufacture of pipe couplings, fittings, related piping systems components and castings.
Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL, United Kingdom Tel: +44 (0)161 205 2321 • Fax: +44 (0)161 455 4459 Website: www.tycofis.com Quality System Cert. No. 014 Assessed to ISO 9001:2008 Scope: Design, installation, servicing and inspection of fire sprinklers, detection, deluge, water spray, foam and gas suppression systems. The following locations are included within the scope of certification:-
20 Nov 2011
617
PART 6: SECTION 1 QUALITY SYSTEMS Belfast Tyco House, 13a Airport Road West, Belfast, Northern Ireland BT8 9ED Birmingham Hawthorns Business Centre, Halfords Lane, Smethwick, Warley, West Midlands B66 1DW Bristol 1610 Park Avenue, Aztec West, Almondsbury, Bristol BS32 4UA Dudley Hillcrest Business Park, Cinderbank, Dudley, West Midlands DY2 9AP Manchester Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL Slough Tyco House, 57-63 Farnham Road, Slough, Berkshire SL1 3TN Swansea Tyco House, Phoenix Way, Swansea SA7 9EQ
Scope: Design, installation, servicing and inspection of fire sprinklers, water spray and foam systems. The following locations are included within the scope of certification:East Kilbride 30-32 Singer Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0XS Newcastle 6 Stirling Court, Eleventh Avenue North, Team Valley Trading Estate, Gateshead, Tyne & Wear NE11 0JF
Scope: Manufacture, installation, servicing and repair of industrial rolling shutters, fire doors, fire rolling shutters and glazed automatic doors. The following locations are included within the scope of certification:Barnsley (Doors) Albion Road, Carlton Industrial Estate, Barnsley, South Yorkshire S71 3HW Manchester (Doors) Tyco Park, Newton Heath, Manchester M40 2WL Wigan (Doors) Unit 4, Bradley Hall Trading Estate, Bradley Lane, Standish, Wigan, Lancashire WN6 OXQ
Scope: The contract service and maintenance of portable fire extinguishers within the UK, at each location and in accordance with BS 5306:3, BS 5306:8. The following locations are included within the scope of certification:Crayford Unit L, Acorn Business Park, Crayford, DA1 4FL East Kilbride 30-32 Singer Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0XS Birmingham Hawthorns Business Centre, Halfords Lane, Smethwick, Warley, West Midlands B66 1DW
618
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Manchester Tyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL
Tyco Fire Products Manufacturing Limited Stockport Trading Estate, Yew Street, Stockport, Cheshire SK4 2JW, United Kingdom Tel: +44 (0)161 429 3400 • Fax: +44 (0)161 477 6729 E-mail: [email protected] • Website: www.tycobuilding.com Sales Enquiries: Tel: +44 (0)161 8750400 • Fax: +44 (0)161 8750491 Quality System Cert. No. 007 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire protection valves, fire sprinklers, high and medium velocity nozzles and controls. Design, manufacture and assembly of foam and gas fire extinguishing systems. Manufacture of fusible links.
Tyco Flow Control (M) Sdn. Bhd. (Tyco Fire Suppression & Building Products, Malaysia) Lot 886, C1 & C2,, Jalan Subang 9, Taman Perindustrian Subang, 47500 Subang, Selangor, Malaysia E-mail: [email protected] • Website: www.tycobuilding.com Quality System Cert. No. 673 Assessed to ISO 9001:2008 Scope: Assembly of couplings and marketing of couplings and fittings.
Tyco Thermal Controls UK Ltd 3 Rutherford Road, Stephenson Industrial Estate, Washington, Tyne & Wear NE37 3HX, United Kingdom Tel: +44 (0)191 419 8200 • Fax: +44 (0)191 419 8201 E-mail: [email protected] • Website: www.tycothermal.com Quality System Cert. No. 063 Assessed to ISO 9001:2008 Scope: Design, manufacture and supply of mineral insulated and flexible cables and assemblies for use in heating, temperature measurement, wiring, displacement measurement, leak detection, signal transmittal and nuclear applications. Design, supply and installation of heat tracing systems.
UK Fire Safety Limited 13-15 Lostock Road, Urmston, Manchester M41 0ES, United Kingdom Tel: +44 (0)161 746 8037 • Fax: +44 (0)161 746 8136 E-mail: [email protected] • Website: www.uk-firesafety.co.uk Quality System Cert. No. 856 Assessed to ISO 9001:2008 Scope: Design, supply, installation, servicing and commissioning of fire sprinkler systems.
20 Nov 2011
619
PART 6: SECTION 1 QUALITY SYSTEMS
UK Firewatch Limited 10 Apollo Court, Koppers Way, Monkton Business Park South, Hebburn, Tyne & Wear NE31 2ES, United Kingdom Tel: +44 (0)191 495 9525 • Fax: +44 (0)191 495 9529 E-mail: [email protected] • Website: www.ukfirewatch.com Quality System Cert. No. 391 Assessed to ISO 9001:2008 Scope: Design, fabrication, installation and maintenance of fixed fire protection systems.
UK Firewatch Limited 37/39 Manor Road, Romford, Essex RM1 2TL, United Kingdom Tel: +44 (0)1708 756248 • Fax: +44 (0)1708 769315 E-mail: [email protected] • Website: www.ukfirewatch.com Quality System Cert. No. 536 Assessed to ISO 9001:2008 Scope: Design, fabrication, installation and servicing of fire sprinkler and water spray systems, hydrants and hosereels.
Ultra Suppression Systems Limited Oakridge House, Wellington Road, High Wycombe, Buckinghamshire HP12 3PR, United Kingdom Tel: +44 (0)1494 444123 • Fax: +44 (0)1494 444345 E-mail: [email protected] • Website: www.ultrass.co.uk Quality System Cert. No. 752 Assessed to ISO 9001:2008 Scope: Design and project management of water mist and gaseous fire suppression systems including installation, commissioning, service and repair.
Universal Fixings Limited New John Street, Halesowen, West Midlands B62 8HT, United Kingdom Tel: +44 (0)1384 422284 • Fax: +44 (0)1384 897446 Quality System Cert. No. 766 Assessed to Factory Production Control to PN 111 Scope: Manufacture of Filbow Hangers.
UTC Fire & Security (Africa) trading as Ziton Ziton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South Africa Tel: +27 21 5066000 • Fax: +27 21 5066100 Website: www.utcfireandsecurity.com Quality System Cert. No. 092 Assessed to ISO 9001:2008 Scope: Manufacture of fire detection and alarm systems and components.
620
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
UTC Fire & Security Americas Corporation, Inc. 129 North Main Street, Pittsfield, ME 04967, United States Tel: +1 207 487 3104 • Fax: +1 207 487 5526 E-mail: [email protected] • Website: www.gesecurity.com 8985 Town Center Parkway, Bradenton FL 34202, United States Tel: +1 941 739 4200 • Fax: +1 941 751 6384 41 Woodford Avenue, Plainville CT 06062, United States
Also at: Technology Center, 129 Hunnewell Avenue, Pittsfield ME 04967, United States Quality System Cert. No. 262 Assessed to ISO 9001:2008 Scope: Design, manufacture and repair of fire detection, fire alarm control and indicating equipment, and customer training.
UTC Fire & Security Services 10 Avenue du Centaure, B.P.38408-95806, Cergy-Pontoise Cedex, France Tel: +33 1 30173737 • Fax: +33 1 30173707 Website: www.chubbsecurite.com Quality System Cert. No. 747 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm system panels.
Ventcroft Limited Goddard Road, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1NQ, United Kingdom Tel: +44 (0)1928 581098 • Fax: +44 (0)1928 581099 E-mail: [email protected] • Website: www.ventcroft.co.uk Quality System Cert. No. 682 Assessed to ISO 9001:2008 Scope: Design and manufacture of electric cables for use in security alarm systems and installations that require safety in the event of fire.
Victaulic Company 2010 Enterprise Drive NE, Leland, North Carolina 28451, United States Tel: +1 910 371 5588 • Fax: +1 910 371 2728 E-mail: [email protected] • Website: www.victaulic.com Quality System Cert. No. 203 Assessed to ISO 9001:2008 Scope: Manufacture of press fit pipe couplings and fittings; elastomeric gaskets and fire sprinklers and accessories.
20 Nov 2011
621
PART 6: SECTION 1 QUALITY SYSTEMS
Victaulic Company 4901 Kesslersville Road, Easton, Pennsylvania 18040, United States Tel: +1 610 559 3300 • Fax: +1 610 250 8817 E-mail: [email protected] • Website: www.victaulic.com Quality System Cert. No. 104 Assessed to ISO 9001:2008 Scope: Design of pipe couplings, fittings, valves, fire sprinklers, grooving tools and related accessories. Manufacture of pipe couplings, fittings, valves and related accessories. Also at: 8023 Quarry Road, Alburtis, Pennsylvania 18011, USA Scope: Casting of pipe couplings, fittings and related accessories. And: 1818 Vultee Street, Allentown, Pennsylvania 18103, USA Scope: Finishes of pipe couplings and fittings for the water supply industry. And: Mold Technology Centre (MTC), 2860 Bath Pike, Suite 300, Nazareth, Pennsylvania 18064, USA Scope: Design and manufacture of elastomeric molds.
Viking Plastics 202 Industrial Drive, Huntsville AL 35811, United States Tel: 001 256 858 3711 • Fax: 001 256 858 3775 E-mail: [email protected] • Website: www.vikingcorp.com Quality System Cert. No. 837 Assessed to ISO 9001:2008 Scope: Manufacture of CPVC fire sprinkler pipe.
Vimpex Limited Star Lane, Great Wakering, Essex SS3 0PJ, United Kingdom Tel: +44 (0) 1702 216999 • Fax: +44 (0) 1702 216699 E-mail: [email protected] • Website: www.vimpex.co.uk Quality System Cert. No. 456 Assessed to ISO 9001:2008 Scope: Design, sub-contract manufacture and distribution of fire alarm warning and evacuation devices, including voice-enhanced sounders and water leak detection systems. Stockholding, distribution, repair and servicing of tools for the emergency services, police and the military. Portable fire fighting equipment, telescopic masts and commercial vehicle accessories.
622
20 Nov 2011
PART 6: SECTION 1 QUALITY SYSTEMS
Vipond Fire Protection Limited 10-12 Glenfield Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0RA, United Kingdom Tel: +44 (0)1355 2375 25/80/88 • Fax: +44 (0)1355 263399 E-mail: [email protected] • Website: www.vipondfire.co.uk Quality System Cert. No. 136 Assessed to ISO 9001:2008 Scope: Design, installation, and servicing of fire sprinkler systems. Design, installation, commissioning and servicing of fire detection and alarm systems. Fabrication of pipework for the sprinkler systems and pipework for carrying fluids.
Vulcan Tanks Limited Cotes Park Lane, Cotes Park Industrial Estate, Alfreton, Derbyshire DE55 4NJ, United Kingdom Tel: +44 (0)1773 835321 • Fax: +44 (0)1773 836578 E-mail: [email protected] • Website: www.cstvulcan.com Quality System Cert. No. 044 Assessed to ISO 9001:2008 Scope: Design, manufacture and installation of fire sprinkler water tanks and industrial storage tanks.
Wagner Group GmbH Schleswigstraße 5, D-30853 Langenhagen, Germany Tel: +49 511 97383 0 • Fax: +49 511 73338 6 E-mail: [email protected] • Website: www.wagner.de Also at: Hanseatenstrasse 52, D-30853 Langenhagen, Germany Quality System Cert. No. 524 Assessed to ISO 9001:2008 Scope: Design, production and distribution of fire detection, fire suppression, fire prevention, risk management, intrusion monitoring and alarm systems.
WOPF Befestigungselemente GmbH Luner Rennbahn 22, D-21339 Luneburg, Germany Tel: +49 4131 30110 • Fax: +49 4131 301198 Website: www.wopf.de Quality System Cert. No. 918 Assessed to Factory Production Control to PN 111 Scope: Development & manufacture of brackets & pipe support systems.
Wrexham Mineral Cables Wynnstay Technology Park, Ruabon, Wrexham, Clwyd LL14 6EN, United Kingdom Tel: +44 (0)1978 810789 • Fax: +44 (0)1978 821502 E-mail: [email protected] • Website: www.wrexhammineralcables.com Quality System Cert. No. 333 Assessed to ISO 9001:2008 Scope: Manufacture of mineral insulated cables and their terminations with a rated voltage not exceeding 750V.
20 Nov 2011
623
PART 6: SECTION 1 QUALITY SYSTEMS
Writech Industrial Services Limited Also including Writech Manufacturing Limited, Mullingar Business Park, Mullingar, Co. Westmeath, Ireland Tel: +353 44 9349857 • Fax: +353 44 9349858 E-mail: [email protected] Quality System Cert. No. 366 Assessed to ISO 9001:2008 Scope: Design, manufacturing, installation, commissioning and servicing of fire sprinkler systems.
Xi'an System Sensor Electronics Limited 28 Tuan Jie South Road, Xi'An Hi-Tech Development Zone, Xi'An, Shaan Xi 710075, China Tel: +86 29 5246253 • Fax: +86 29 5239673 E-mail: [email protected] Also at: 40# Zhangbar Er Road, National Xi'an Hi-Tech Industrial Development Zone, Xi'an, China Tel: +86 29 85387800 • Fax: +86 29 88332796 Quality System Cert. No. 641 Assessed to ISO 9001:2008 Scope: Design, manufacture and repair of fire detection and alarm system components. Manufacture of water flow alarm switches.
Xtratherm Limited Kells Road, Navan, Co. Meath, Ireland Tel: +353 46 906 6000 • Fax: +353 46 906 6090 E-mail: [email protected] • Website: www.xtratherm.com Quality System Cert. No. 851 Assessed to ISO 9001:2008 Scope: Manufacture of rigid foam insulation.
Xtratherm UK Limited Park Road, Holmewood Industrial Park, Holmewood, Chesterfield, Derbyshire S42 5UY, United Kingdom Tel: +44 (0)1246 858100 • Fax: +44 (0)1246 857447 E-mail: [email protected] • Website: www.xtratherm.com Quality System Cert. No. 718 Assessed to ISO 9001:2008 Scope: Manufacture of rigid foam insulation.
Zeta Alarm Systems by GLT Exports Limited Detection House, 72-78 Morfa Road, Swansea SA1 2EN, United Kingdom Tel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176 E-mail: [email protected] • Website: www.gltexports.com Quality System Cert. No. 330 Assessed to ISO 9001:2008 Scope: Design and manufacture of fire detection and alarm systems and components.
624
20 Nov 2011
PART 6: SECTION 2 ENVIRONMENTAL SYSTEMS
Businesses face a growing number of environmental pressures including: Energy prices Water prices Concerns from the public about pollution, climate change and resources Legislation Environmental Taxes (climate change levy, landfill tax etc) Waste disposal Environmental impact assessment Prosecution ISO 14001 is a clear way of demonstrating a company’s commitment to the ‘green’ culture, and provides an assurance to the public, regulators and purchasers that the environmental policies and procedures the company puts into place help to:
Address public concerns Reduce risk of legal non-compliance (Environmental Protection Act 1990 and a whole host of others) Reduce costs and tax burden (Climate Change Levy and rebates) Improve reputation and marketability Manage environmental performance
Assessment and evaluation of environmental management systems can lead to products, systems and services that directly improve the quality of life through cleaner, safer and healthier environments.
Apollo Fire Detectors Limited 36 Brookside Road, Havant, Hampshire PO9 1JR, United Kingdom Tel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754 E-mail: [email protected] Quality System Cert. No. EMS 010 Assessed to ISO 14001:2004 Scope: Design and manufacture of fire detection equipment.
Hochiki Europe (UK) Limited Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United Kingdom Tel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132 Website: www.hochikieurope.com Quality System Cert. No. EMS 164 Assessed to ISO 14001:2004 Scope: Design, manufacture, service and maintenance of fire detection and alarm equipment.
J W Singer Handlemaker Road, Frome, Somerset BA11 4RW, United Kingdom Tel: +44 (0)1373 462201 • Fax: +44 (0)1373 473156 E-mail: [email protected] • Website: www.jwsinger.com Quality System Cert. No. EMS 925 Assessed to ISO 14001:2004 Scope: Manufacture of brass sprinkler heads for the fire protection industry.
20 Nov 2011
625
PART 6: SECTION 2 ENVIRONMENTAL SYSTEMS
Kingspan Ltd Carrickmacross Road, Kingscourt, Co. Cavan, Ireland Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77 E-mail: [email protected] • Website: www.kingspanpanels.com Quality System Cert. No. EMS 186 Assessed to ISO 14001:2004 Scope: Design and manufacture of fire resistant wall and roof cladding materials and industrial wall and roof cladding materials, multi-beam purlins and accessories, gutters, flashing system and single and double translucent roof lights.
Kingspan Ltd trading as Kingspan Structural, Kingspan Fabrications, Kingspan Controlled Environments (KCE), Kingspan Profiles and Sections Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom Tel: +44 (0)1944 710591 • Fax: +44 (0)1944 710777 E-mail: [email protected] • Website: www.wards.co.uk Quality System Cert. No. EMS 279 Assessed to ISO 14001:2004 Scope: Design and manufacture of foam filled fire resistant insulated panels for roof, wall and cold store applications and ancillaries, cold rolled Multi-Beam, rail and channel sections, floor deck profiles; flashings, building ancillaries and architectural façade systems. Design, manufacture and installation of Kingframe building systems and cold rolled steel sections. Pre-treatment and protective coating to steel and galvanized components for architecturtal and industrial applications.
Kingspan Ltd. Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161 E-mail: [email protected] • Website: www.kingspanpanels.com Quality System Cert. No. EMS 260 Assessed to ISO 14001:2004 Scope: Manufacture of fire resistant and industrial wall and roof cladding materials.
KingspanTarec Industrial Insulation Limited Glossop Brook Road, Glossop, Derbyshire SK13 8GF, United Kingdom Tel: +44 (0)870 733 0021 • Fax: +44 (0)870 700 0022 E-mail: [email protected] • Website: www.kingspantarec.co.uk Quality System Cert. No. EMS 035-2 Assessed to ISO 14001:2004 Scope: Manufacture of polyurethane and phenolic rigid foam insulation.
Project Fire Products Limited (incorporating Project Fire Engineers) Pasturefields Lane Industrial Estate, Pasturefields Lane, Hixon, Staffordshire ST18 0PH, United Kingdom Tel: +44 (0)1889 270999 • Fax: +44 (0)1889 270974 E-mail: [email protected] • Website: www.projectfire.co.uk Quality System Cert. No. EMS 060 Assessed to ISO 14001 Scope: Design, installation and servicing of fire sprinkler and water spray systems. Assembly, installation and commissioning, repair and servicing of water flow switch and alarm valve testing devices.
626
20 Nov 2011
PART 6: SECTION 2 ENVIRONMENTAL SYSTEMS
Protec International Limited Construction House, Adlington Industrial Estate, Adlington, Cheshire SK10 4NL, United Kingdom Tel: +44 (0)1625 855666 • Fax: +44 (0)1625 855601 E-mail: [email protected] • Website: www.protection.co.uk Tel: 0800 834 704 • Fax: 0800 834 705 Quality System Cert. No. EMS 843 Assessed to ISO 14001:2004 Scope: The procurement and supply of specialist temporary protection materials including LPS 1207 and LPS 1215 flame retardant products for the building and construction industry.
Ruskin Air Management Limited Joseph Wilson Industrial Estate, South Street, Whitstable, Kent CT5 3DU, United Kingdom Tel: +44 (0)1227 276100 • Fax: +44 (0)1227 264262 E-mail: [email protected] • Website: www.actionair.co.uk Also at: Stourbridge Road, Bridgnorth, Shropshire WV15 5BB, United Kingdom Quality System Cert. No. EMS 017 Assessed to ISO 14001:2004 Scope: Manufacture and supply of fire protection, weather protection and air distribution products.
Safe Partnership 3 East Street, Wareham, Dorset BH20 4NN, United Kingdom Tel: +44 (0)1929 551100 • Fax: +44 (0)1929 553300 E-mail: [email protected] • Website: www.safepartnership.co.uk Quality System Cert. No. EMS 835 Assessed to ISO 14001 Scope: Manufacture, supply, installation and repair of timber doors. Supply installation, maintenance and repair of domestic physical security products.
SPP Pumps Limited Theale Cross, Pincents Lane, Calcot, Reading, Berkshire RG31 7SP, United Kingdom Tel: +44 (0)118 932 3123 • Fax: +44 (0)118 932 3302 E-mail: [email protected] • Website: www.spppumps.com Quality System Cert. No. EMS 111 Assessed to ISO 14001:2004 Scope: Design, manufacture and supply of pumps, pump packages and generator sets for use in construction, building services, oil and gas and water industries as well as general industry. Project management and the assembly of pump packages and generators including associated documentation. Service and provision of spare parts, repair and maintenance of pumps, valves, compressors and other allied equipment. Sites covered by this Approval: Sales & Service Centre: Theale Cross, Pincents Lane, Calcot, Reading, Berkshire RG31 7SP UK Design & Manufacture : Crucible Close, Muschet Industrial Park, Coleford, Gloucestershire GL16 8PS UK Service Centre: Tufthorn Avenue, Coleford, Gloucestershire GL16 8PJ UK Service Centre: Unit 2, Oak Bank, Channel Commercial Park, Belfast, Northern Ireland BT3 9DT
20 Nov 2011
627
PART 6: SECTION 2 ENVIRONMENTAL SYSTEMS Service Centre: Unit 1, Stanstead Road, Eastleigh, Hampshire SO50 4RZ UK Service Centre: Greg Street, Reddish, Stockport, Cheshire SK5 7BU UK
Technocover Limited (incorporating TechnoRail and Strataform) Henfaes Lane, Welshpool, Powys SY21 7BE, United Kingdom Tel: +44 (0)1938 555511 • Fax: +44 (0)1938 555527 E-mail: [email protected] • Website: www.technocover.co.uk Quality System Cert. No. EMS 450 Assessed to ISO 14001:2004 Scope: The design, manufacture and installation of metal security covers, doors, grating and staging.
Tyco Fire Products Manufacturing Limited Stockport Trading Estate, Yew Street, Stockport, Cheshire SK4 2JW, United Kingdom Tel: +44 (0)161 429 3400 • Fax: +44 (0)161 477 6729 E-mail: [email protected] • Website: www.tycobuilding.com Quality System Cert. No. EMS 007 Assessed to ISO 14001:2004 Scope: Design and manufacture of fire protection valves, fire sprinklers, high and medium velocity nozzles and controls.
Xtratherm UK Limited Park Road, Holmewood Industrial Park, Holmewood, Chesterfield, Derbyshire S42 5UY, United Kingdom Tel: +44 (0)1246 858100 • Fax: +44 (0)1246 857447 E-mail: [email protected] • Website: www.xtratherm.com Quality System Cert. No. EMS 718 Assessed to ISO 14001:2004 Scope: Manufacture of rigid foam insulation.
628
20 Nov 2011
PART 6: SECTION 3 HEALTH & SAFETY CERTIFICATION BS OHSAS 18001
HSE statistics show that some thirty million working days were lost due to work related health and safety issues In the UK in 2006/07. Poor health and safety performance not only means loss of revenue, but also loss of reputation, license to trade and business, and huge extra costs. In some instances it can lead to very large fines or custodial sentences. Good health and safety performance reduces costs and gives companies a competitive edge. BS OHSAS 18001 is a specification that helps to fully integrate health and safety into company policies and working practices. This in turn helps the company to identify risks, engage staff and continuously improve processes and systems. It also signals to architects, clients, insurers and specifiers that the company takes its health and safety responsibilities seriously. The assessment standard for this scheme is: BS OHSAS 18001:2007 Occupational health and safety management systems - Requirements.
Argus Fire Protection Company Limited Hendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA, United Kingdom Tel: +44 (0)1384 376256 • Fax: +44 (0)1384 393955 E-mail: [email protected] • Website: www.argusfire.co.uk Quality System Cert. No. 011-HS Assessed to OHSAS 18001:2007 Scope: Design, supply and installation, servicing and maintenance of fire protection and detection systems, including site based activities.
Kingspan Ltd Carrickmacross Road, Kingscourt, Co. Cavan, Ireland Tel: +353 42 969 8572 • Fax: +353 42 969 8576/77 E-mail: [email protected] • Website: www.kingspanpanels.com Quality System Cert. No. 186-HS Assessed to OHSAS 18001:2007 Scope: Design and manufacture of fire resistant wall and roof cladding materials and industrial wall and roof cladding materials, multi-beam purlins and accessories, gutters, flashing system and single and double translucent roof lights.
Kingspan Ltd trading as Kingspan Structural, Kingspan Fabrications, Kingspan Controlled Environments (KCE), Kingspan Profiles and Sections Sherburn, Malton, North Yorkshire YO17 8PQ, United Kingdom Tel: +44 (0)1944 710591 • Fax: +44 (0)1944 710777 E-mail: [email protected] • Website: www.wards.co.uk Quality System Cert. No. 279-HS Assessed to OHSAS 18001:2007 Scope: Design and manufacture of foam filled fire resistant insulated panels for roof, wall and cold store applications and ancillaries, cold rolled Multi-Beam, rail and channel sections, floor deck profiles; flashings, building ancillaries and architectural façade systems. Design, manufacture and installation of Kingframe building systems and cold rolled steel sections. Pre-treatment and protective coating to steel and galvanized components for architecturtal and industrial applications.
20 Nov 2011
629
PART 6: SECTION 3 HEALTH & SAFETY CERTIFICATION BS OHSAS 18001
Kingspan Ltd. Greenfield Business Park No. 2, Greenfield, Holywell, Flintshire CH8 7HU, United Kingdom Tel: +44 (0)1352 716100 • Fax: +44 (0)1352 716161 E-mail: [email protected] • Website: www.kingspanpanels.com Quality System Cert. No. 260-HS Assessed to OHSAS 18001:2007 Scope: Manufacture of fire resistant and industrial wall and roof cladding materials.
Xtratherm UK Limited Park Road, Holmewood Industrial Park, Holmewood, Chesterfield, Derbyshire S42 5UY, United Kingdom Tel: +44 (0)1246 858100 • Fax: +44 (0)1246 857447 E-mail: [email protected] • Website: www.xtratherm.com Quality System Cert. No. 718-HS Assessed to OHSAS 18001:2007 Scope: Manufacture of rigid foam insulation.
630
20 Nov 2011