Transcript
LP-MH Series Laser Projector
Add: Room 605, Butouxin 1 Xiang 25, Nanan Road, Guangzhou, GD510160. China Tel: 0086-20-81271628 Fax: 0086-20-81271917 Website: www.laserpic.com www.laserphoto.org
Thank you for purchasing our MH series laser projector. In order to use this product safely and throughly. Please read over this manual carefully before use,the operation must according to manual strictly to avoid any personal hurt or products damage . Any problem exclude in this manual please contact us!.
Specification Series Number
LP-MH-S
Model Reference#
LP-MH-S-L-150RGY
Components
Laser projector×1pc Power cable×1pc DMX512 cable×1pc
Using voltage
AC 110V~230V,50/60Hz
Control Mode
Auto/AUDIO/DMX
DMX channel
16
Scanning system
LP-MH-S-H: Reference to new LP30 manual LP-MH-S-L: Reference to LP12 manual
Lasers&Power
LP-MH-S-R.G.Y: Power select:50~100mW LP-MH-S-RGY:Power:150mW
Using temperature
10℃
Dimension(mm)
370(L)×280(W)×450(H)
Weight(kg)
12
Safety fuse
250V / F2A Φ5×20mm
~ 40℃
ATTENTION&MAINTENANCE 1,Do not disconnect the device without professional instruction 2,Keep surrounding dry and clean.this unit should be keep dry, do not use in the rain or dank and dusty environment. Projector should be covered with water-proof when operate at outside. 3,Keep surrounding temperature at15~30℃,Remain 10minutes for equipment cooling after 2 hours continuously work,or laser expected time will be reduced. 4,Distance between lasing aperture and projected item should not be less than 1 meter. 5,Do not turn device on/off frequently to avoid broken. 6,Do not look into the laser beam directly,or view laser beam directly with optical II
instruments. 7,Do not touch the device with wet hands. 8,Turn off the power before installation and maintenance. 9. When the laser diode became dim or broken, please contact the dealer timely. 11. To use the original package when transport again and to avoid shake. 12.Maintenance should be performed every 15-day period, by using a sponge which is dipped with alcohol, rather than wet cloth or other chemical liquid, to clean the mirror.
WARNING Class 3B laser products,keep safety warning to avoid any hurt when using in public!
INSTALLATION Back panel instruction
SYSTEM---System working indicator If the light shines constantly,it indicates the inner systems of the moving head light is working properly SIGNAL--Signal indicator Indicator constantly on,DMX512 signal receive correctly; Indicator flicker,DXM512 signal is online; Indicator off:Receive DMX512 signal inaccurately,or fail to exit the inner function choice-
III
menu,or signal is not DMX512. ERROR--Error indicator This indicator works together with the error information of the LCD and it belongs to the self-diagnosing function of the moving head light.it goes out when the moving head works properly. LCD--Multi-functional LCD MENU--Menu function button Press MENU button to enter or quit the menu with function list.;Press to cancel the edition when editing the functions. UP--Backward-rolling button DOWN--Forward-rolling button ENTER--Enter button
POWER UP: When you connected power supply, 3 led indicator lights will flicker one by one after 5 seconds, indicating the projector is self-checking, and LCD display as follow:
Please
waiting
initializing Self-checking end, LCD display as follow:
Receiving DMX512 Address code:001 ‘001” is the address code of the initial channel, reset allowed.
Function Introduction: I , Choose Address Code The laser projector receive signals as ISSTP DMX-512, In order to identify and send signals, need assign channels for every projector. Details as follows: 1, press “MENU” to enter menu desk. 2, Press “UP” or “DOWN” to choose function , until LCD display as follow:
Adjust Address 3, If need modify address code, press “ENTER”, The primary address code display.( take
IV
“001” as an example)
Address code: .......001 4, press “UP” or “DOWN” to choose desirable address code.(the address code of initial channel). 5, press “ENTER” to confirm memory. 6, press “MENU” to back menu desk, then the new address code you have chosen will be displayed.
II,Change Effect In order to different requirements in various occasions and different needs in the same occasion. Do as following steps, You can change the pre-programed effect easily. ( To change vertical and horizontal moving direction, and don't need program). Operation process as following: 1, press “MENU” enter menu desk 2, press”UP” or ”DOWN”
Change Pan direction 3, If you want to change the vertical moving direction, press” ENTER” ,LCD display primary program status.(eg: Obverse direction)
Pan direction: obverse 4, press “UP” or “DOWN” to edit.( change direction from obverse to reverse , OR change direction from reverse to obverse).
Pan direction: Reverse 5, press “ENTER” to confirm the setup 6, press “MENU” to back menu desk, run the former program,and you will find the horizontal program effect(Pan)of the beams has been changed. 7, change vertical(Tilt) direction as the same way as horizontal. III , Hardware initialization( Reset system)
V
1, press “MENU” enter menu desk 2, press “UP” or “DOWN” until displaying as follow:
Reset system 3, press “ENTER”, Reset finished. IV, Channel Self-testing 1, press “MENU” enter menu desk 2,press “UP” or “DOWN” until display as follow:
Test channels. 3, press “ENTER” ,LCD will display as follow:
Select channel. Channel:01 4, press “UP” or “DOWN” to choose the channel need check. 5, press “ENTER” to confirm the check, LCD display follow:
Testing… Vaule: 180 NOTE: value code will be displayed if any error happened, when this happen,check again or choose any other channel recheck. V, Working Times Stat. Projector will record and stat. working times automatically, you could learn easy how many times you used. This function just for read, can not be edit. Operation steps as follows: 1, press “MENU” to enter function menu. 2, press “UP” or ”DOWN” until displaying as follow, the number is the total working times. ( take 100 times as an example)
Already Work 100 Times VI, Auto Mode AutoMode program was installed in the projector, the equipment could auto running without the console. Operation as follows:
VI
1, press “MENU” enter menu desk 2, press “ UP” or “ DOWN” to choose following entry.
Automode setting 3,press “ENTER” to confirm, enter subentry, LCD displays as follow:
Auto Running: Stop 4, press “UP” or “DOWN” to choose follow:
Auto Running: Start 5, press “ENTER” to back primary entry, display as follow:
Auto Mode setting 6, press “MENU” to enter “auto running” mode, As follow will be displayed when auto running started :
Auto Running: In demo 7, To exit auto mode according to the same process, the only difference is change “start” to replace “stop”.
VII,Automatic transmission failures check When failures happened for the control system, part of failure information will be display,and “ERROR” LED on, which help professional maintenance man to clear the problems.
Connect DMX There are a female and a male DMX512 input sockets on the side of pedestal. And the pins of both sockets are “GND” “ + ” and “ - ”, do not reverse. Connect with STP(Shielded Twisted Pair) cable or two cores shield cable.
VII
Ways and Means : Take the signal cable of the controller to connect the first projector, then connect the second projector with the signal cable of the first projector. And as the same manner till all of the projectors are connected.
Suggestions and special instructions: ※Need the control of concole when the moving head is running AUTO-MODE,please follow VI, Auto Mode to stop the and choose the address code as instruction I , Choose Address Code. ※The light of LCD is auto active, To press any button to turn on the light of LCD screen, and turn off automatically after 10 second if no action. ※Do not disassemble the projector yourself, because there no replaceable parts inside. ※The distance between projector to screen should longer than 1 meter. ※ In order to prolong the using time, please do not turn on and off frequently, To avoid working continuously for a long time, Lay off more than 15 seconds to cool the equipment after two hours working.
DMX CH1: CH2: CH3: CH4: CH5: CH6: CH7: CH8: CH9: CH10: CH11: CH12: CH13: CH14: CH15: CH16:
Channels instruction X SCAN Horizontal 370 °/550° Y SCAN Vertical 280°/300° X&Y SCANNING SPEED Control mode(SOUND,AUTO&DMX) Blanking/Color Patterns Speed of laser effect Rolling of patterns Rotation&Spotting Movement of patterns Extention of patterns ZOOM Slow draw Node definition Change color speed Pattern size
Product design and specifications are subject to change without notice.
LASERPHOTO at Mar.2007
VIII