LP SERIES-General Purpose LP6-60 (6V60AH) Specification Nominal Voltage
6V
Nominal Capacity(10HR)
60.0AH
Dimensions
Length Width Container Height Total Height (with Terminal)
Approx Weight Terminal
Approx 9.1 kg (20.1lbs)
Container Material
ABS
Rated Capacity
62.4 AH/3.12A 60.0 AH/6.00A 51.5 AH/10.3A 46.8 AH/15.6A 36.6 AH/36.6A
185±2mm (7.28 inches) 112±2mm (4.41 inches) 205±3mm (8.07 inches) 205±3mm (8.07 inches)
T2 (20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F)
Applications All purpose Uninterruptable Power Supply (UPS) Electric Power System (EPS)
Max. Discharge Current
720A (5s)
Internal Resistance
Approx 7mΩ
Emergency backup power supply 0
Emergency light
0
Discharge : -15~50 C (5~122 F) Charge : 0~400C (32~1040F) Storage : -15~400C (5~1040F)
Operating Temp.Range Nominal Operating Temp. Range Cycle Use
Railway signal Aircraft signal
25±30C (77±50F )
Alarm and security system
Initial Charging Current less than18.0A.Voltage
Electronic apparatus and equipment
7.2V~7.5V at 250 C(770 F)Temp. Coefficient -15mV/0C
Standby Use
Communication power supply
No limit on Initial Charging Current Voltage
DC power supply
6.75V~6.9V at 250 C(770 F)Temp. Coefficient -10mV/0C
Auto control system
40o C (104o F) 103% 100% 25o C ( 77o F) o o 86% 0 C ( 32 F) Leoch LP series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.
Capacity affected by Temperature
Self Discharge
VdS
t est ed
9
Germany
Constant Current Discharge (Amperes) at 25 0C (77 0F ) F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
102.7
80.7
68.7
57.4
45.6
34.5
28.3
18.0
14.2
11.6
9.38
8.17
6.63
5.66
3.09
1.80V/cell
137.8
103.2
83.0
67.9
53.9
40.2
31.7
19.7
15.3
12.4
10.1
8.76
7.03
6.00
3.12
1.75V/cell
155.4
113.4
90.6
73.0
55.9
41.7
33.2
20.4
15.6
12.7
10.3
9.00
7.15
6.06
3.15
1.70V/cell
171.1
123.5
96.7
76.7
58.2
43.4
34.2
21.2
16.1
13.0
10.6
9.19
7.25
6.12
3.21
1.65V/cell
188.7
133.3
102.9
81.5
61.4
44.4
35.3
21.8
16.7
13.5
10.9
9.39
7.37
6.25
3.25
1.60V/cell
208.2
144.8
110.0
86.9
64.8
46.3
36.6
22.5
17.2
13.9
11.2
9.59
7.44
6.31
3.27
Constant Power Discharge (Watts/cell) at 25 0C (77 0F ) F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
187.8
149.1
128.1
108.2
87.0
66.4
54.6
35.0
27.8
22.7
18.4
16.0
13.1
11.2
6.12
1.80V/cell
249.3
188.3
152.7
126.1
101.1
76.6
60.8
37.9
29.7
24.2
19.7
17.1
13.8
11.8
6.17
1.75V/cell
275.2
203.6
164.8
134.3
104.1
78.8
63.3
39.2
30.1
24.6
20.1
17.6
14.0
12.0
6.22
1.70V/cell
294.6
216.9
173.5
140.1
107.7
81.6
65.1
40.7
30.9
25.2
20.6
17.9
14.2
12.1
6.34
1.65V/cell
320.2
231.9
183.0
147.7
112.7
82.9
66.8
41.6
32.1
26.0
21.1
18.2
14.4
12.3
6.41
1.60V/cell
345.1
246.0
192.5
155.7
118.2
85.9
68.8
42.7
32.9
26.7
21.7
18.6
14.5
12.4
6.44
Specifications subject to change without notice.
1
Dimensions T2 Terminal
0.8 [0.031]
8 [0.31]
112±2 61
205±3 198.5±2 188.5±2
6.35 [0.250]
Unit: mm [inches]
66.5 185±2
Discharge Characteristics 6V Battery (V)
Float Charging Characteristics
Temperature:25 0 C(77 0 F)
Charging Current
Charge Volume
6.5
(XCA)
% 6.0
Terminal Voltage(V)
Charging Voltage 0.10CA-2.25V/cell
0
temperature25 C
(V)
0.25 120 110
5.5
0.4C
5.0
1C
4.5
0.205C
7.0
90 80
Charge Voltage (Constant 2.25v/cell)
0.15
6.5
70 60
0.6C
After 50% Discharge
0.10
50
6.0
40 4.0
After 100% Discharge
30
2C 1
2
4
6
8 10
40
20
2
60
6 8 10
4
H
Min
0.05
20 10 0
20
7.5
Charged Volume
0.20
100
0.1C 0.0525C
5.5
Charging Current 0 0
8
4
12
16
20
24
32
28
36
40
Discharge Time
Charging Time(hours)
Temperature Effects in Relation to Battery Capacity
Effect of Temperature on Long Term Float Life
120
10
Float Life(year)
100
Capacity(%)
8
0.1CA 0.17CA 0.25CA
80 60 40
6 5 4
Charging voltage : 2.25V/cell
3 2
1
20 0.5
-20
0
-10
10
20
30
40
50
20 68
60
30 86
Temperature( C)
Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity.
Remaining Capacity(%)
100
Capcity(%)
80 60
0 0
50% DOD
400
600
800
1000
A
250C
B
60 300C
400C
40
C
20 0
30% DOD
100C
80
0
2
6
4
8
10
12
Storage Time(Months)
Ambient Termperature: 25oC (77oF)
200
C F
O
100
120
20
0
Self Discharge Characteristics
Cycle Life in Relation to Depth of Discharge
100% DOD
50 122
Battery temperature
0
40
40 104
A
No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.)
B
Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA .
C
Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached.
1200
Number of Cycles
Sales Office China sales office:
HongKong sales office:
Singapore sales office:
North America sales office:
Europe sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd.,
Workshop C, 33/F, TML Tower,
Add: No. 1 Tech Park Crescent,
Add: 19751 Descartes, Unit A,
Add: 9B Wheatstone Court. Waterwells
Nanshan,Shenzhen, China. 518052
No. 3 Hoi Shing Road, Tsuen Wan,
Singapore 638131
Foothill Ranch, CA 92610, USA
Business Park, Gloucester, GL2-2AQ,
Tel: +86-755-86036060 (100 lines)
New Territories, Hong Kong
Tel: +65 68636078
Tel: 949-588-5853
UK United Kingdom
Fax: +86-755-26067269
Tel: +852 35786666
Fax: +65 68636079
Fax: 949-588-5966
Tel: +44(0) 1452 729428 / 1452 729696
E-mail:
[email protected]
Fax: +852 21170016
Email
[email protected]
E-mail:
[email protected]
Fax: +44 (0)1452-690125
Http://www.leoch.com
E-mail:
[email protected]
Http://www.leoch.com
Http://www.leoch.com
E-mail:
[email protected] Publication No.:LB-LP-7-17
2