LP SERIES-General Purpose LP6-60 (6V60AH) Specification Nominal Voltage 6V Nominal Capacity(10HR) 60.0AH Dimensions Length Width Container Height Total Height (with Terminal) Approx Weight Terminal Approx 9.1 kg (20.1lbs) Container Material ABS Rated Capacity 62.4 AH/3.12A 60.0 AH/6.00A 51.5 AH/10.3A 46.8 AH/15.6A 36.6 AH/36.6A 185±2mm (7.28 inches) 112±2mm (4.41 inches) 205±3mm (8.07 inches) 205±3mm (8.07 inches) T2 (20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Applications All purpose Uninterruptable Power Supply (UPS) Electric Power System (EPS) Max. Discharge Current 720A (5s) Internal Resistance Approx 7mΩ Emergency backup power supply 0 Emergency light 0 Discharge : -15~50 C (5~122 F) Charge : 0~400C (32~1040F) Storage : -15~400C (5~1040F) Operating Temp.Range Nominal Operating Temp. Range Cycle Use Railway signal Aircraft signal 25±30C (77±50F ) Alarm and security system Initial Charging Current less than18.0A.Voltage Electronic apparatus and equipment 7.2V~7.5V at 250 C(770 F)Temp. Coefficient -15mV/0C Standby Use Communication power supply No limit on Initial Charging Current Voltage DC power supply 6.75V~6.9V at 250 C(770 F)Temp. Coefficient -10mV/0C Auto control system 40o C (104o F) 103% 100% 25o C ( 77o F) o o 86% 0 C ( 32 F) Leoch LP series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 Germany Constant Current Discharge (Amperes) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 102.7 80.7 68.7 57.4 45.6 34.5 28.3 18.0 14.2 11.6 9.38 8.17 6.63 5.66 3.09 1.80V/cell 137.8 103.2 83.0 67.9 53.9 40.2 31.7 19.7 15.3 12.4 10.1 8.76 7.03 6.00 3.12 1.75V/cell 155.4 113.4 90.6 73.0 55.9 41.7 33.2 20.4 15.6 12.7 10.3 9.00 7.15 6.06 3.15 1.70V/cell 171.1 123.5 96.7 76.7 58.2 43.4 34.2 21.2 16.1 13.0 10.6 9.19 7.25 6.12 3.21 1.65V/cell 188.7 133.3 102.9 81.5 61.4 44.4 35.3 21.8 16.7 13.5 10.9 9.39 7.37 6.25 3.25 1.60V/cell 208.2 144.8 110.0 86.9 64.8 46.3 36.6 22.5 17.2 13.9 11.2 9.59 7.44 6.31 3.27 Constant Power Discharge (Watts/cell) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 187.8 149.1 128.1 108.2 87.0 66.4 54.6 35.0 27.8 22.7 18.4 16.0 13.1 11.2 6.12 1.80V/cell 249.3 188.3 152.7 126.1 101.1 76.6 60.8 37.9 29.7 24.2 19.7 17.1 13.8 11.8 6.17 1.75V/cell 275.2 203.6 164.8 134.3 104.1 78.8 63.3 39.2 30.1 24.6 20.1 17.6 14.0 12.0 6.22 1.70V/cell 294.6 216.9 173.5 140.1 107.7 81.6 65.1 40.7 30.9 25.2 20.6 17.9 14.2 12.1 6.34 1.65V/cell 320.2 231.9 183.0 147.7 112.7 82.9 66.8 41.6 32.1 26.0 21.1 18.2 14.4 12.3 6.41 1.60V/cell 345.1 246.0 192.5 155.7 118.2 85.9 68.8 42.7 32.9 26.7 21.7 18.6 14.5 12.4 6.44 Specifications subject to change without notice. 1 Dimensions T2 Terminal 0.8 [0.031] 8 [0.31] 112±2 61 205±3 198.5±2 188.5±2 6.35 [0.250] Unit: mm [inches] 66.5 185±2 Discharge Characteristics 6V Battery (V) Float Charging Characteristics Temperature:25 0 C(77 0 F) Charging Current Charge Volume 6.5 (XCA) % 6.0 Terminal Voltage(V) Charging Voltage 0.10CA-2.25V/cell 0 temperature25 C (V) 0.25 120 110 5.5 0.4C 5.0 1C 4.5 0.205C 7.0 90 80 Charge Voltage (Constant 2.25v/cell) 0.15 6.5 70 60 0.6C After 50% Discharge 0.10 50 6.0 40 4.0 After 100% Discharge 30 2C 1 2 4 6 8 10 40 20 2 60 6 8 10 4 H Min 0.05 20 10 0 20 7.5 Charged Volume 0.20 100 0.1C 0.0525C 5.5 Charging Current 0 0 8 4 12 16 20 24 32 28 36 40 Discharge Time Charging Time(hours) Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life 120 10 Float Life(year) 100 Capacity(%) 8 0.1CA 0.17CA 0.25CA 80 60 40 6 5 4 Charging voltage : 2.25V/cell 3 2 1 20 0.5 -20 0 -10 10 20 30 40 50 20 68 60 30 86 Temperature( C) Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. Remaining Capacity(%) 100 Capcity(%) 80 60 0 0 50% DOD 400 600 800 1000 A 250C B 60 300C 400C 40 C 20 0 30% DOD 100C 80 0 2 6 4 8 10 12 Storage Time(Months) Ambient Termperature: 25oC (77oF) 200 C F O 100 120 20 0 Self Discharge Characteristics Cycle Life in Relation to Depth of Discharge 100% DOD 50 122 Battery temperature 0 40 40 104 A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles Sales Office China sales office: HongKong sales office: Singapore sales office: North America sales office: Europe sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Workshop C, 33/F, TML Tower, Add: No. 1 Tech Park Crescent, Add: 19751 Descartes, Unit A, Add: 9B Wheatstone Court. Waterwells Nanshan,Shenzhen, China. 518052 No. 3 Hoi Shing Road, Tsuen Wan, Singapore 638131 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2-2AQ, Tel: +86-755-86036060 (100 lines) New Territories, Hong Kong Tel: +65 68636078 Tel: 949-588-5853 UK United Kingdom Fax: +86-755-26067269 Tel: +852 35786666 Fax: +65 68636079 Fax: 949-588-5966 Tel: +44(0) 1452 729428 / 1452 729696 E-mail:[email protected] Fax: +852 21170016 Email [email protected] E-mail: [email protected] Fax: +44 (0)1452-690125 Http://www.leoch.com E-mail: [email protected] Http://www.leoch.com Http://www.leoch.com E-mail: [email protected] Publication No.:LB-LP-7-17 2