Transcript
LP SERIES-General Purpose LP12-2.9 (12V2.9AH) Specification Nomial Voltage
12V
Nomial Capacity(20HR)
2.9AH
Dimension
Length Width Container Height Total Height (with Terminal)
79 56 99 105
1mm (3.11 inches) 1mm (2.20 inches) 1mm (3.90 inches) 2mm (4.13 inches)
Mainten
T1
Container Material
ABS
Rated Capacity
2.90 AH/0.145A 2.70 AH/0.27A 2.45 AH/0.49A 2.22 AH/0.74A 1.82 AH/1.82A
AH) 9(12V2.9 ry LP12-2. id Batte d Lead-ac
e Seale
TA NT
VO LTA
GE CH
13. 5-1 3.8 y use : Sta ndb 14. 4-1 5.0 use : n Cy cle Les s tha ren t: Init ial cur
Do not burn s. : on, or nera te. War ningfire, exp losi O or inci Risk of ve the 50 C, hea t abo
Approx 1.1 kg (2.43lbs)
Approx Weight Terminal
ance-fre
CO NS
disa ssem
Pb.
43.5A (5s)
Internal Resistance
Approx 55mÙ
(20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F)
All purpose Uninterruptable Power Supply (UPS) Emergency backup power supply
Discharge : -15 50 C (5 122 F) Charge : 0 400C (32 1040F) Storage : -15 400C (5 1040F)
Nominal Operating Temp. Range
25
Emergency light Railway signal Aircraft signal
30C (77 50F )
Alarm and security system
Initial Charging Current less than 0.87A.Voltage
Electronic apparatus and equipment
14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C
Communication power supply
No limit on Initial Charging Current Voltage
DC power supply
13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C
Auto control system
40o C (104o F) 103% 100% 25o C ( 77o F) 86% 0o C ( 32o F) Leoch LP series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.
Self Discharge
Pb
Applications
0
Operating Temp.Range
Capacity affected by Temperature
ble,
Electric Power System (EPS) 0
Standby Use
V V 0.8 7 A
6 able MH2 686 Non-spill RECYCLED BE . Y CO.,LTD BATTERY MUST BATTER LEOCH E IN CHINA MAD
Max. Discharge Current
Cycle Use
AR GE
VdS
t est ed
9 0
Germany
0
Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
5.52
4.24
3.51
3.04
2.35
1.73
1.46
0.86
0.67
0.55
0.447
0.388
0.313
0.262
0.144
1.80V/cell
7.41
5.42
4.24
3.59
2.77
2.01
1.63
0.94
0.73
0.59
0.480
0.416
0.332
0.270
0.145
1.75V/cell
8.36
5.95
4.64
3.86
2.88
2.09
1.71
0.98
0.74
0.60
0.493
0.428
0.338
0.277
0.146
1.70V/cell
9.20
6.49
4.95
4.06
2.99
2.17
1.76
1.00
0.76
0.61
0.505
0.437
0.343
0.282
0.149
1.65V/cell 10.15
7.00
5.26
4.31
3.16
2.23
1.80
1.02
0.79
0.64
0.519
0.446
0.348
0.288
0.151
1.60V/cell 11.19
7.60
5.63
4.59
3.34
2.32
1.82
1.06
0.82
0.66
0.537
0.456
0.351
0.291
0.152
Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
10.1
7.83
6.56
5.73
4.48
3.33
2.81
1.67
1.32
1.07
0.877
0.763
0.618
0.518
0.284
1.80V/cell
13.4
9.89
7.81
6.67
5.20
3.84
3.13
1.82
1.41
1.14
0.937
0.815
0.654
0.533
0.287
1.75V/cell
14.8
10.7
8.43
7.11
5.36
3.94
3.26
1.88
1.43
1.16
0.959
0.835
0.664
0.547
0.289
1.70V/cell
15.8
11.4
8.87
7.41
5.54
4.09
3.36
1.92
1.46
1.19
0.981
0.851
0.672
0.557
0.294
1.65V/cell
17.2
12.2
9.36
7.81
5.80
4.15
3.41
1.94
1.52
1.23
1.005
0.867
0.681
0.568
0.298
1.60V/cell
18.6
12.9
9.85
8.23
6.08
4.30
3.42
2.01
1.56
1.26
1.034
0.883
0.686
0.573
0.299
1
Dimensions T1 Terminal
CONSTANT VOLTAGE CHARGE
Standby
use:
Cycle
use:
13.5-13.8
V
14.4-15.0
Initial current:
Less t han
V 0.87 A
0.8 [0.031]
Warning: Risk of fire, explosion, or burns. Do not disassemble, heat above the 50 O C, or incinerate.
3.2 [0.126] 6.35 [0.25]
56 1
LP12-2.9 (12V2.9AH) Maintenance-free Sealed Lead-acid Battery
99 1 105 2
4.75 [0.187]
Unit: mm [inches]
MH26866
Pb. LEOCH BATTERY CO.,LTD.
Non-spillable
MADE IN CHINA
BATTERY MUST BE RECYCLED
Pb
79 1
Discharge Characteristics 12V Battery V
Float Charging Characteristics 0
0
Charging Charging Current Voltage
Charge Volume
Temperature:25 C(77F)
13.0
Terminal Voltage(V)
12.0
0
0.10CA-2.25V/cell
(V)
(XCA)
%
temperature25 C
0.25 120 110
11.0
0.4C
10.0
90 80
15.0
50
Charged Volume
0.20 14.0 Charge Voltage (Constant 2.25v/cell)
0.15 13.0
70 60
0.628C
1C
9.0
0.207C
100
0.093C 0.05C
0.10
After 50% Discharge 12.0
40 8.0
30
3C 1
2
4
6
2C
8 10
2
60
40
20
4
6 8 10
20 10 0
20
H
Min
After 100% Discharge 0.05
11.0
Charging Current 0 0
4
8
16
12
20
32
28
24
36
40
Discharge Time
Charging Time(hours)
Temperature Effects in Relation to Battery Capacity
Effect of Temperature on Long Term Float Life 10
120
8
Life expectancy(year)
Capacity %
80
0 .2 C A
60
1 .0 C A
40
2 .0 C
20 0 -20
6 5 4
A 0 .0 5 C A 0 .1 C
100
A
3. 0C A
Charging voltage : 2.25V/cell
3 2
1
0.5
-10
20
10
0
30
50
40
30 86
20 68
0
Temperature( C)
Remaining Capacity(%)
Capcity(%)
80 60 50% DOD
400
600
800
1000
B
60 300C
400C
40
C
20 0
30% DOD
A
250C
2
4
6
8
10
12
Storage Time(Months)
Ambient Termperature: 25oC (77oF)
200
100C
80
100
0 0
C F
O
100
120
20
0
Self Discharge Characteristics
Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity.
100% DOD
50 122
Battery temperature
Cycle Life in Relation to Depth of Discharge
40
40 104
A
No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.)
B
Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA .
C
Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached.
1200
Number of Cycles
Sales Office China sales office:
North America sales office:
Europe sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Nanshan,Shenzhen, China. 518052 Tel:+ 86-755-86036060 (100 lines) Fax: +86-755-26067269 E-mail:
[email protected] Http://www.leoch.com
Add: 19751 Descartes, Unit A, Foothill Ranch, CA 92610, USA Tel: 949-588-5853 Fax: 949-588-5966 E-mail:
[email protected] Http://www.leoch.us
Add: 9B Wheatstone Park, Waterwells Business Park, Gloucester, GL2 2AQ. UK. Tel: +44(0) 1452 729428 Fax: +44 (0)1452-690125 E-mail:
[email protected]
2