Preview only show first 10 pages with watermark. For full document please download

Lp12-90

   EMBED


Share

Transcript

LP SERIES-General Purpose LP12-90 (12V90AH) Specification Nominal Voltage 12V Nominal Capacity(10HR) 90.0AH Dimensions 330 3mm (12.99 inches) Length 173 2mm (6.81 inches) Width 212 3mm (8.35 inches) Container Height Total Height (with Terminal) 220 3mm (8.66 inches) Approx Weight Terminal Approx 28.0 kg (61.7lbs) Container Material ABS Rated Capacity 93.6 AH/4.68A 90.0AH/9.0A 77.5 AH/15.5A 70.2AH/23.4A 54.9 AH/54.9A T11 Max. Discharge Current 1080A (5s) Internal Resistance Approx 5.0mÙ (20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Applications All purpose Uninterruptable Power Supply (UPS) Electric Power System (EPS) Emergency backup power supply 0 Emergency light 0 Operating Temp.Range Discharge : -15 50 C (5 122 F) Charge : 0 400C (32 1040F) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 Railway signal Aircraft signal 30C (77 50F ) Alarm and security system Initial Charging Current less than27.0A.Voltage Cycle Use Electronic apparatus and equipment 14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C Standby Use Communication power supply No limit on Initial Charging Current Voltage DC power supply 13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C Auto control system 40o C (104o F) 103% 100% 25o C ( 77o F) 86% 0o C ( 32o F) Leoch LP series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 0 Germany Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 154.0 121.1 103.0 86.1 68.5 51.8 42.4 27.0 21.4 17.5 14.1 12.2 9.95 8.50 4.64 1.80V/cell 206.8 154.7 124.4 101.8 80.8 60.3 47.5 29.5 23.0 18.6 15.1 13.1 10.5 9.00 4.68 10min 15min 1.75V/cell 233.1 170.0 135.9 109.5 83.9 62.5 49.7 30.6 23.4 19.1 15.5 13.5 10.7 9.09 4.73 1.70V/cell 256.7 185.3 145.1 115.1 87.3 65.0 51.3 31.8 24.1 19.6 15.9 13.8 10.9 9.18 4.82 1.65V/cell 283.1 200.0 154.3 122.3 92.1 66.7 53.0 32.7 25.1 20.2 16.3 14.1 11.1 9.37 4.88 1.60V/cell 312.2 217.1 165.0 130.3 97.2 69.5 54.9 33.8 25.9 20.9 16.9 14.4 11.2 9.47 4.91 Constant Power Discharge (Watts/cell) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 281.6 223.7 192.2 162.4 130.5 99.6 81.8 52.5 41.6 34.1 27.6 24.1 19.6 16.8 9.18 1.80V/cell 374.0 282.5 229.1 189.1 151.6 114.9 91.2 56.9 44.6 36.2 29.5 25.7 20.8 17.8 9.26 1.75V/cell 412.7 305.4 247.1 201.5 156.1 118.1 95.0 58.8 45.2 36.9 30.2 26.4 21.1 17.9 9.33 1.70V/cell 441.9 325.3 260.2 210.2 161.6 122.4 97.6 61.0 46.4 37.8 30.9 26.9 21.3 18.1 9.51 1.65V/cell 480.4 347.9 274.5 221.6 169.1 124.3 100.2 62.3 48.1 39.0 31.6 27.4 21.6 18.4 9.62 1.60V/cell 517.6 369.1 288.7 233.5 177.2 128.9 103.2 64.1 49.4 40.1 32.5 27.9 21.8 18.6 9.66 1 Dimensions Unit: mm [inches] Terminal: T11 20 [0.787] 173 2 220 2 212 2 6 [0.236] M8 [0.315] 330 Discharge Characteristics Float Charging Characteristics 12V 6V 4V 2V Battery Battery Battery Battery V V V V 13.0 6.5 4.33 Charging Charging Current Voltage Charge Volume Temperature:25 0 C(77 0 F) 2.16 Terminal Voltage(V) 6.0 4.00 2.00 11.0 5.5 3.66 1.84 9.0 5.0 4.5 3.33 3.00 0.205C 0.4C 1.68 1C 1.52 15.0 14.0 90 80 Charge Voltage (Constant 2.25v/cell) 0.15 13.0 70 60 0.6C Charged Volume 0.20 100 0.0525C 0.10 50 After 50% Discharge 12.0 40 8.0 4.0 2.67 temperature25 C 0.25 120 110 0.1C 10.0 0 0.10CA-2.25V/cell (V) (XCA) % 12.0 2 1.36 After 100% Discharge 30 2C 1 2 6 8 10 4 40 20 60 2 4 6 8 10 H Min 0.05 20 10 0 20 11.0 Charging Current 0 0 4 8 16 12 20 32 28 24 36 40 Discharge Time Charging Time(hours) Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life 120 10 6 5 4 0.25CA 80 Life expectancy(year) % 100 Capacity 8 0.1CA 0.17CA 60 40 Charging voltage : 2.25V/cell 3 2 1 20 0.5 -20 0 -10 10 20 30 40 50 20 68 60 30 86 Temperature( C) Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. 60 B 60 400 40 C 20 0 30% DOD 600 800 1000 300C 400C 2 6 4 8 10 12 Storage Time(Months) Ambient Termperature: 25oC (77oF) 200 A 250C Remaining Capacity(%) Capcity(%) 80 50% DOD 100C 80 100 0 0 C F O 100 120 20 0 Self Discharge Characteristics Cycle Life in Relation to Depth of Discharge 100% DOD 50 122 Battery temperature 0 40 40 104 A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles Sales Office China sales office: North America sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Add: 19751 Descartes, Unit A, Europe sales office: Singapore sales office: HongKong sales office: Add: 9B Wheatstone Park, Waterwells Add: No.53,Ubi Avenue 1, #03-21 Paya Add: Unit 3910,39/F,Cable TV Tower,No.9 Nanshan,Shenzhen, China. 518052 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2 2AQ. UK. Ubi Industrial Park, Singapore 408934 Hoi Shing Road,Tsuen Wan, NT.H.K Tel:+8 6-755-86036060 (100 lines) Tel: 949-588-5853 Tel: +44(0) 01452 729428 Tel:+ 65 6841 6629 Tel: +852 3578 6666 E -mail: [email protected] E-mail: [email protected] Fax: +86-755-26067269 Fax: 949-588-5966 Fax: +44 (0)1452-690125 E-mail:[email protected] E-mail: [email protected] E-mail: [email protected] Http://www.leoch.com Http://www.leoch.us 2