Preview only show first 10 pages with watermark. For full document please download

Lp6-150

   EMBED


Share

Transcript

LP SERIES-General Purpose LP6-150 (6V150AH) Specification Nominal Voltage 6V Nominal Capacity(10HR) 150.0AH Dimensions Length Width Container Height Total Height (with Terminal) Approx Weight Terminal Approx 21.0 kg (46.3lbs) Container Material ABS Rated Capacity 156.0 AH/7.80A 150.0 AH/15.0A 129.0 AH/25.8A 117.0 AH/39.0A 91.5 AH/91.5A 260±3mm (10.2 inches) 180±2mm (7.09 inches) 247±3mm (9.72 inches) 253±3mm (9.96 inches) LP6-150( nan Ma inte ing: 1500A (5s) Internal Resistance Approx 3.0mΩ (20hr ,1.80V/cell,250C/770F) (10hr,1.80V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) All purpose Uninterruptable Power Supply (UPS) Emergency backup power supply Emergency light 0 Railway signal Aircraft signal 25±30C (77±50F ) Alarm and security system Initial Charging Current less than 45.0A.Voltage Electronic apparatus and equipment 7.2V~7.5V at 250 C(770 F)Temp. Coefficient -15mV/0C Communication power supply No limit on Initial Charging Current Voltage DC power supply 6.75V~6.9V at 250 C(770 F)Temp. Coefficient -10mV/0C Auto control system 40o C (104o F) 103% 100% 25o C ( 77o F) o o 86% 0 C ( 32 F) Leoch LP series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge BE RECYCLED Applications Discharge : -15~50 C (5~122 F) Charge : 0~400C (32~1040F) Storage : -15~400C (5~1040F) Standby Use e Non-spillabl BATTERY MUST Electric Power System (EPS) 0 Cycle Use ) Bat ter y semb le, Pb. R 6V150AH Lea d-a cid not disas MADE Max. Discharge Current Nominal Operating Temp. Range Sea led MH26 866 TD. ERY CO.,L LEOCH BATTIN CHINA T7 Operating Temp.Range ce- fre e burn s. Do sion, or Warn erate . fire, exploO Risk of e the 50 C, or incin heat abov VdS t est ed 9 Germany Constant Current Discharge (Amperes) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 256.7 201.8 171.6 143.6 114.1 86.4 70.7 45.0 35.6 29.1 23.5 20.4 16.6 14.2 7.73 1.80V/cell 344.6 257.9 207.4 169.7 134.6 100.4 79.2 49.2 38.3 31.1 25.2 21.9 17.6 15.0 7.80 1.75V/cell 388.5 283.4 226.5 182.6 139.8 104.2 82.9 51.0 39.0 31.8 25.8 22.5 17.9 15.1 7.88 1.70V/cell 427.9 308.9 241.8 191.9 145.5 108.4 85.5 53.0 40.1 32.6 26.5 23.0 18.1 15.3 8.03 1.65V/cell 471.8 333.3 257.2 203.8 153.5 111.1 88.4 54.5 41.8 33.7 27.2 23.5 18.4 15.6 8.13 1.60V/cell / 361.9 275.0 217.1 162.0 115.8 91.5 56.3 43.1 34.8 28.1 24.0 18.6 15.8 8.18 Constant Power Discharge (Watts/cell) at 25 0C (77 0F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 469.4 372.8 320.3 270.6 217.5 166.0 136.4 87.5 69.4 56.9 46.0 40.1 32.7 28.0 15.3 1.80V/cell 623.4 470.8 381.8 315.2 252.7 191.6 152.0 94.8 74.3 60.4 49.1 42.9 34.6 29.6 15.4 1.75V/cell 687.9 509.0 411.9 335.8 260.2 196.9 158.3 98.0 75.4 61.5 50.3 43.9 35.1 29.9 15.6 1.70V/cell 736.5 542.2 433.6 350.3 269.3 204.0 162.7 101.7 77.3 63.0 51.4 44.8 35.6 30.2 15.8 1.65V/cell 800.6 579.8 457.5 369.3 281.8 207.2 167.0 103.9 80.2 65.0 52.7 45.6 36.1 30.7 16.0 1.60V/cell / 615.1 481.2 389.2 295.4 214.8 172.0 106.9 82.3 66.8 54.2 46.5 36.3 31.0 16.1 Specifications subject to change without notice. 1 Dimensions T7 Terminal Unit: mm [inches] φ18[0.709] 90±1 1 8 0±2 253±3 247±3 6[0.236] M6[0.236] 260±3 Discharge Characteristics 6V Battery (V) Float Charging Characteristics Temperature:25 0 C(77 0 F) Charging Current Charge Volume 6.5 (XCA) % 6.0 Terminal Voltage(V) Charging Voltage 0.10CA-2.25V/cell 0 temperature25 C (V) 0.25 120 110 5.5 0.4C 5.0 1C 4.5 0.205C 7.0 90 80 Charge Voltage (Constant 2.25v/cell) 0.15 6.5 70 60 0.6C After 50% Discharge 0.10 50 6.0 40 4.0 After 100% Discharge 30 2C 1 2 4 6 8 10 40 20 2 60 6 8 10 4 H Min 0.05 20 10 0 20 7.5 Charged Volume 0.20 100 0.1C 0.0525C 5.5 Charging Current 0 0 8 4 12 16 20 24 32 28 36 40 Discharge Time Charging Time(hours) Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life 120 10 Float Life(year) 100 Capacity(%) 8 0.1CA 0.17CA 0.25CA 80 60 40 6 5 4 Charging voltage : 2.25V/cell 3 2 1 20 0.5 -20 0 -10 10 20 30 40 50 20 68 60 30 86 Temperature( C) Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. Remaining Capacity(%) 100 Capcity(%) 80 60 0 0 50% DOD 400 600 800 1000 A 250C B 60 300C 400C 40 C 20 0 30% DOD 100C 80 2 6 4 8 10 12 Storage Time(Months) Ambient Termperature: 25oC (77oF) 200 C F O 100 120 20 0 Self Discharge Characteristics Cycle Life in Relation to Depth of Discharge 100% DOD 50 122 Battery temperature 0 40 40 104 A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles Sales Office China sales office: HongKong sales office: Singapore sales office: North America sales office: Europe sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Workshop C, 33/F, TML Tower, Add: No. 1 Tech Park Crescent, Add: 19751 Descartes, Unit A, Add: 9B Wheatstone Court. Waterwells Nanshan,Shenzhen, China. 518052 No. 3 Hoi Shing Road, Tsuen Wan, Singapore 638131 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2-2AQ, Tel: +86-755-86036060 (100 lines) New Territories, Hong Kong Tel: +65 68636078 Tel: 949-588-5853 UK United Kingdom Fax: +86-755-26067269 Tel: +852 35786666 Fax: +65 68636079 Fax: 949-588-5966 Tel: +44(0) 1452 729428 / 1452 729696 E-mail:[email protected] Fax: +852 21170016 Email [email protected] E-mail: [email protected] Fax: +44 (0)1452-690125 Http://www.leoch.com E-mail: [email protected] Http://www.leoch.com Http://www.leoch.com E-mail: [email protected] Publication No.:LB-LP-7-17 2