Lpc12-90 (12v90ah) Specification

   EMBED


Share

Transcript

LPC SERIES -Deep Cycle LPC12-90 (12V90AH) Specification Nomial Voltage 12V Nomial Capacity(10HR) 90.0AH Length Width Container Height Total Height (with Terminal) Approx 27.0 Kg (59.5 Ibs) Dimension Approx Weight Terminal T6 Container Material ABS Rated Capacity 96.4 AH/4.82A 90.0 AH/9.0A 79.0 AH/15.8A 71.7 AH/23.9A 58.1 AH/58.1A 305 168 207 213 2mm (12.01 inches) 2mm (6.61 inches) 2mm (8.15 inches) 2mm (8.38 inches) Warning: Risk of fire, explosion, or burns. Do not disassemble, O heat above the 50 C, or incinerate. MADE IN CHINA (20hr ,1.80V/cell,250C/77 0F) (10hr,1.80V/cell,250C/77 0F) (5hr,1.75V/cell,250C/77 0F) (3hr,1.75V/cell,250C/77 0F) (1hr,1.60V/cell,250C/77 0F) Max. Discharge Current 1080A (5s) Internal Resistance Approx 5.0mÙ Operating Temp.Range Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 Cycle Use Initial Charging Current less than 27.0A.Voltage 14.4V~15.0V at 25 0 C(77 0 F)Temp. Coefficient -30mV/ 0C Standby Use No limit on Initial Charging Current Voltage 13.5V~13.8V at 25 0 C(77 0 F)Temp. Coefficient -20mV/ 0C Applications Electric tools Vehicle in place of walking Lawn mowers Golf trolleys and golf cart Portable apparatus, lights and instruments; Electric toys Illumination light Fire alarms Portable power Wheelchairs Medical equipments. 3 0C (77 5 0F ) 103% 40o C (104o F) 100% 25o C ( 77o F ) 86% 0o C ( 32o F ) Leoch LPC series batterys may be stored for up to 6 months at 25 0 C(77 0F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 Germany 0 Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 131.8 110.9 96.9 69.7 55.4 44.9 27.9 21.8 17.6 14.3 12.5 10.2 8.50 4.78 1.80V/cell 168.4 134.0 114.5 82.3 64.4 50.3 30.5 23.4 18.8 15.4 13.4 10.8 9.00 4.82 1.75V/cell 185.0 146.3 123.2 85.4 66.8 52.7 31.6 23.9 19.2 15.8 13.8 11.0 9.09 4.87 1.70V/cell 201.6 156.2 129.5 88.9 69.5 54.3 32.9 24.5 19.8 16.2 14.1 11.2 9.18 4.96 1.65V/cell 217.6 166.1 137.5 93.8 71.2 56.2 33.8 25.6 20.4 16.6 14.4 11.3 9.37 5.02 1.60V/cell 236.3 177.7 146.5 99.0 74.3 58.1 34.9 26.3 21.1 17.2 14.7 11.4 9.47 5.05 10h 20h Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 1.85V/cell 245.9 209.0 184.6 134.0 107.1 87.2 54.4 42.5 34.5 28.1 24.7 20.2 16.8 9.56 1.80V/cell 309.9 248.8 214.9 156.2 123.6 97.1 59.0 45.5 36.7 30.1 26.4 21.4 17.8 9.64 1.75V/cell 336.4 269.2 229.3 161.3 127.6 101.2 61.0 46.2 37.4 30.9 27.1 21.7 18.0 9.72 1.70V/cell 361.5 285.3 239.6 167.3 132.3 104.2 63.3 47.4 38.3 31.6 27.6 22.0 18.1 9.89 1.65V/cell 387.4 301.3 253.4 175.7 135.1 107.3 64.9 49.3 39.6 32.4 28.2 22.3 18.5 10.0 1.60V/cell 413.4 318.4 267.1 183.6 139.6 110.2 66.7 50.6 40.6 33.3 28.7 22.5 18.7 10.0 1 Dimensions T6 Terminal Unit: mm [inches] 16 [0.63] Warning: Risk of fire, explosion, or burns. Do not disassemble, O heat above the 50 C, or incinerate. 168+2 LPC12-90(12V90AH) Maintenance-free Sealed Lead-acid Battery 41 207+2 213+2 6 [0.236] M6 [0.236] R MH26866 Pb. LEOCH BATTERY CO.,LTD. Non-spillable MADE IN CHINA BATTERY MUST BE RECYCLED 242 2 305 2 Discharge Characteristics Charging Characteristics (cycle use) 6V Battery12V Battery (V) (V) Terminal Voltage(V) 6.5 0 Temperature 25C Charging Characteristics Charge Volume 13.0 6.0 12.0 5.5 11.0 0.1C 0.054C 0.214C 5.0 10.0 4.5 9.0 Charged Voltage (A) (V/cell) 100 0.1C 2.5 80 0.08C 2.4 60 0.06C 2.3 40 0.04C 2.2 20 0.02C 2.1 Charge At 0.1C Amp initial charging current and 2.45V/Cell Constant o Voltage at 25C Charged Volume Charge Voltage (Constant 2.45v/cell) 0.365C 3.8C 4.0 Charging Current % 120 2.6C 1.1C 0.646C After 50% Discharge 8.0 1 4 2 6 8 10 min 20 40 60 4 2 6 8 10 H After 100% Discharge Charging Current (initial at 0.1c Amp) 0C 20 0 4 8 12 16 20 24 28 Charging Time(hours) Discharge Time Temperature Effects in Relation to Batter Capacity Cycle Life in Relation to Depth of Discharge Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 2.45V/cell,max. 0.25CA; Charging volume:125% of discharged capacity. 120 120 0.1CA 0.12CA 0.21CA 80 1CA 60 2CA 3CA 100 80 Capcity(%) Capacity (%) 100 40 20 60 100% DOD 50% DOD 30% DOD 40 20 0 -20 -10 10 0 20 30 40 0 50 0 200 Temperature(0C) 400 600 800 1000 1200 1400 1600 1800 Number of Cycles Self Discharge Characteristics 100 Remaining Capacity(%) 100C 80 A A 0 25 C B 60 30 C 40 C 40 Supplementary charge required before use.Optional charging way as below: 0 0 No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. C 20 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 3.Charged for 8~10hours at limted current 0.05CA . 0 0 2 6 4 8 10 C 12 Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. Storage Time(Months) Sales Office China sales office: North America sales office: Europe sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Nanshan,Shenzhen, China. 518052 Tel:+ 86-755-86036060 (100 lines) Fax: +86-755-26067269 E-mail:[email protected] Add: 19751 Descartes, Unit A, Foothill Ranch, CA 92610, USA Tel: 949-588-5853 Fax: 949-588-5966 E-mail: [email protected] Add: LaCampagna House. Main Road. Gloucester. GL2-8JH. United Kingdom Tel: +44(0) 1452 751016 E-mail: [email protected] 2