Transcript
LPC SERIES -Deep Cycle LPC12-90 (12V90AH) Specification Nomial Voltage
12V
Nomial Capacity(10HR)
90.0AH
Length Width Container Height Total Height (with Terminal) Approx 27.0 Kg (59.5 Ibs)
Dimension
Approx Weight Terminal
T6
Container Material
ABS
Rated Capacity
96.4 AH/4.82A 90.0 AH/9.0A 79.0 AH/15.8A 71.7 AH/23.9A 58.1 AH/58.1A
305 168 207 213
2mm (12.01 inches) 2mm (6.61 inches) 2mm (8.15 inches) 2mm (8.38 inches) Warning: Risk of fire, explosion, or burns. Do not disassemble, O heat above the 50 C, or incinerate.
MADE IN CHINA
(20hr ,1.80V/cell,250C/77 0F) (10hr,1.80V/cell,250C/77 0F) (5hr,1.75V/cell,250C/77 0F) (3hr,1.75V/cell,250C/77 0F) (1hr,1.60V/cell,250C/77 0F)
Max. Discharge Current
1080A (5s)
Internal Resistance
Approx 5.0mÙ
Operating Temp.Range
Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F)
Nominal Operating Temp. Range
25
Cycle Use
Initial Charging Current less than 27.0A.Voltage 14.4V~15.0V at 25 0 C(77 0 F)Temp. Coefficient -30mV/ 0C
Standby Use
No limit on Initial Charging Current Voltage 13.5V~13.8V at 25 0 C(77 0 F)Temp. Coefficient -20mV/ 0C
Applications Electric tools Vehicle in place of walking Lawn mowers Golf trolleys and golf cart Portable apparatus, lights and instruments; Electric toys Illumination light Fire alarms Portable power Wheelchairs Medical equipments.
3 0C (77 5 0F )
103% 40o C (104o F) 100% 25o C ( 77o F ) 86% 0o C ( 32o F ) Leoch LPC series batterys may be stored for up to 6 months at 25 0 C(77 0F) and then a freshening charge is required. For higher temperatures the time interval will be shorter.
Capacity affected by Temperature
Self Discharge
VdS
t est ed
9 0
Germany
0
Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
131.8
110.9
96.9
69.7
55.4
44.9
27.9
21.8
17.6
14.3
12.5
10.2
8.50
4.78
1.80V/cell
168.4
134.0
114.5
82.3
64.4
50.3
30.5
23.4
18.8
15.4
13.4
10.8
9.00
4.82
1.75V/cell
185.0
146.3
123.2
85.4
66.8
52.7
31.6
23.9
19.2
15.8
13.8
11.0
9.09
4.87
1.70V/cell
201.6
156.2
129.5
88.9
69.5
54.3
32.9
24.5
19.8
16.2
14.1
11.2
9.18
4.96
1.65V/cell
217.6
166.1
137.5
93.8
71.2
56.2
33.8
25.6
20.4
16.6
14.4
11.3
9.37
5.02
1.60V/cell
236.3
177.7
146.5
99.0
74.3
58.1
34.9
26.3
21.1
17.2
14.7
11.4
9.47
5.05
10h
20h
Constant Power Discharge (Watts) at 25 0C (77 0F ) F.V/Time
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
1.85V/cell
245.9
209.0
184.6
134.0
107.1
87.2
54.4
42.5
34.5
28.1
24.7
20.2
16.8
9.56
1.80V/cell
309.9
248.8
214.9
156.2
123.6
97.1
59.0
45.5
36.7
30.1
26.4
21.4
17.8
9.64
1.75V/cell
336.4
269.2
229.3
161.3
127.6
101.2
61.0
46.2
37.4
30.9
27.1
21.7
18.0
9.72
1.70V/cell
361.5
285.3
239.6
167.3
132.3
104.2
63.3
47.4
38.3
31.6
27.6
22.0
18.1
9.89
1.65V/cell
387.4
301.3
253.4
175.7
135.1
107.3
64.9
49.3
39.6
32.4
28.2
22.3
18.5
10.0
1.60V/cell
413.4
318.4
267.1
183.6
139.6
110.2
66.7
50.6
40.6
33.3
28.7
22.5
18.7
10.0
1
Dimensions T6 Terminal Unit: mm [inches] 16 [0.63]
Warning: Risk of fire, explosion, or burns. Do not disassemble, O heat above the 50 C, or incinerate.
168+2
LPC12-90(12V90AH) Maintenance-free Sealed Lead-acid Battery
41
207+2 213+2
6 [0.236]
M6 [0.236]
R
MH26866
Pb.
LEOCH BATTERY CO.,LTD.
Non-spillable
MADE IN CHINA
BATTERY MUST BE RECYCLED
242 2 305 2
Discharge Characteristics
Charging Characteristics (cycle use)
6V Battery12V Battery (V) (V)
Terminal Voltage(V)
6.5
0 Temperature 25C
Charging Characteristics Charge Volume
13.0
6.0
12.0
5.5
11.0 0.1C 0.054C 0.214C
5.0
10.0
4.5
9.0
Charged Voltage
(A)
(V/cell)
100
0.1C
2.5
80
0.08C
2.4
60
0.06C
2.3
40
0.04C
2.2
20
0.02C
2.1
Charge At 0.1C Amp initial charging current and 2.45V/Cell Constant o Voltage at 25C
Charged Volume
Charge Voltage (Constant 2.45v/cell)
0.365C 3.8C
4.0
Charging Current
% 120
2.6C
1.1C
0.646C
After 50% Discharge
8.0
1
4
2
6 8 10 min
20
40 60
4
2
6 8 10 H
After 100% Discharge
Charging Current (initial at 0.1c Amp)
0C
20
0
4
8
12
16
20
24
28
Charging Time(hours)
Discharge Time
Temperature Effects in Relation to Batter Capacity
Cycle Life in Relation to Depth of Discharge Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 2.45V/cell,max. 0.25CA; Charging volume:125% of discharged capacity.
120 120
0.1CA 0.12CA 0.21CA
80
1CA
60
2CA 3CA
100 80
Capcity(%)
Capacity (%)
100
40 20
60
100% DOD
50% DOD
30% DOD
40 20
0 -20
-10
10
0
20
30
40
0
50
0
200
Temperature(0C)
400
600
800
1000 1200 1400 1600 1800
Number of Cycles
Self Discharge Characteristics 100
Remaining Capacity(%)
100C
80
A
A
0
25 C
B
60 30 C
40 C
40
Supplementary charge required before use.Optional charging way as below:
0
0
No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.)
B
2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
C
20
1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 3.Charged for 8~10hours at limted current 0.05CA .
0 0
2
6
4
8
10
C
12
Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached.
Storage Time(Months)
Sales Office China sales office:
North America sales office:
Europe sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Nanshan,Shenzhen, China. 518052 Tel:+ 86-755-86036060 (100 lines) Fax: +86-755-26067269 E-mail:
[email protected]
Add: 19751 Descartes, Unit A, Foothill Ranch, CA 92610, USA Tel: 949-588-5853 Fax: 949-588-5966 E-mail:
[email protected]
Add: LaCampagna House. Main Road. Gloucester. GL2-8JH. United Kingdom Tel: +44(0) 1452 751016 E-mail:
[email protected]
2